Loading...
113 Grovewood Ave 15-2659IA c �CEWED CITY OF SANFORD AUG 2 0 2015 BUILDING & FIRE PREVENTION BY: PERMIT APPLICATION Application No: /E_ r� (p S-9 9 Documented Construction Value: $ Job Address: iI 3 (o f ovC.v po l A, S Z_'R3 Historic District: Yes ❑ NoK Parcel ID: I L)--20 -: co ^SOS - O O— O 00 Residential ❑ Commercial ❑ Type of Work: New ❑ Addition ❑ Alterations Repair a Demo ❑ Change of Use ❑ Move ❑ Description of Work: RW\cLLc 6A) Az0J Q) LAJ1n&'_J u--Ot,� wavvo Plan Review Contact Person: WoIR'(1,/J&jkN Title: AA -V -v Phone: \ Fax: tt6*>r- 61 y --b 161 Email: Carla o-I&�enwjw' 4 A. '(oam Property Owner Information Name 03\,o 6crc,4 -Ayi1 _(Zt& 4aA- Cqni;gJ Street: i �3 Nc City, State Zip: Sc -4--'a `-�_ Phone: Resident of property? Contractor Information Name 6� G (&rkc t (ti/7 Phone: Street: 5-05- S0 SSS Q -Sk 200 Fax: If6)- 0 (6 1 City, State Zip: ao lq�' 3ZV3 State License No.: 64PC(�;025l Architect/Engineer Information Name: Phone:SZ-3— Z�3� Street: (P01%4 4I CAI c6� �rj&C q4k . Fax: City, St, Zip: ( ,'QOtIPr ; - ?✓�'1�� E-mail: Bonding Company: Address: Mortgage Lender: Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performedJ6 meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: 5" Edition (2014) Florida Building Code Revised: June 30, 2015 #1 -?/ .06 Permit Application EXISTING LIVING EXISTING HOUSE EXISTING KITCHEN EXISTING FAMILY RM. EXISTING BEDROOM y CUT CMU WALL TO INSTALL 35SH WIND❑W (EGRESS) NEW L-6 LINTEL • (N❑ FILL, NO STEEL EXISTING BEDROOM TYPICAL RETRO FIT CELL IF NOT EXISTING (SEE DETAIL) (2 L❑CATI❑NS) EXISTING BEDROOM FLOOR PLAN IMPORTANT NOTES ENERGY CALCULATIONS TO BE PERFORMED BY AN AIR CONDITIONING COMPANY PRIOR TO SUBMITTING PLANS TO CITY/COUNTY FOR REVIEW. AIR CONDITION COMPANY IS ALSO TO DESIGN HEATING AND A/C DUCTING PLAN FOR OWNER. (IF APPLY) OWNER TO SUPPLY WINDOW & DOOR MANUFACTURED SPECIFICATIONS FOR CITY/COUNTY WITH PLANS SUBMITTAL FOR FLORIDA BUILDING CODE APPROVAL. CONTRATOR TO FIELD VERIFY ALL DIMENSIONS PRIOR TO BEGINNING OF CONSTRUCTION. THESE PLANS WERE DEVELOPED FROM FIELD MEASUREMENTS OF HOME AND VARY SLIGHTLY. Total Allowable Superimposed Load U -Precast Lintel U -Precast Lintel - Pounds Per Linear Foot (8"X8") (8"XI6" composite) Mark o, Nominal Total No Fill Filled Filled Filled Filled Filled Clear Lintel No STEEL (145 (245 (145 T&B (D#5T(2)#5B (2)#5 T & B San San A B C D E L-6 416' 5'10' 2045 2577 2669 4028 4120 4212 Note' (P,S) represent precast lintels prestressed using (2) 7/16' Diameter Prestressing Strands, t4n..� FLORIDA PRODUCT APPROVAL If FL 158-R1 W/ 2014 REVISION GENERAL NOTES D CODES, 1.1 FLORIDA RESIDENTIAL BUILDING CODE 2014, 12 BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE (ACI 318-98), 1.3 AMERICAN SOCIETY OF CIVIL ENGINEERS MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES (ASCE.7-10), 2) CONCRETE, 21 CONCRETE COMPRESSIVE STRENGTH AT 28 DAYS, ZIA PRE -CAST W/STANDARD REINFORCEMENT - 3500 PSI 212, PRE -CAST W/PRESTRESS REINFORCEMENT - 5000 PSI 213, CONCRETE FILL (PLACED IN FIELD) - 2500 PSI 22 REINFORCING BARS, 23 PRESTRESS STRANDS ASTM A416 7 -WIRE 24 DETAIL REINFORCEMENT IN ACCORDANCE WITH ACI 315, 2,5 CONCRETING OPERATIONS SHALL COMPLY WITH ACI STANDARDS, 3) MASONRY, 3.1 DESIGN AND CONSTRUCTION SHALL CONFORM TO THE SPECIFICAfDIN OF THE NATIONAL CONCRETE MASONRY ASSOCIATION AND ACI 530, 32 MINIMUM MASONRY UNIT STRENGTH, F'n 1250 PSI, 33 MORTAR SHALL BE TYPE S. 4) STRUCTURAL, 4,1 SAFE LOAD VALUES ARE BASED ON LINTELS HAVING A BEARING OF 8' (WITH A MINIMUM ACCEPTABLE BEARING OF 4' PER SECTION 210131 OF THE 2010 EDITION OF THE FLORIDA RESIDENTIAL BUILDING CODE) 5) CONTRACTOR, ` 5,1 CONTRACTOR/MASON TO VERIFY ALL LINTEL SPANS, PRIOR TO ORDERING/ INSTALLATION 6) CONTRACTOR, 61 ENGINEER OF RECORD MUST BE NOTIFIED FOR REVIEW IF GARAGE LINTEL IS LESS THAN 8X16 COMPOSITE NOTE, EXTRA TIE BEAMS OR COURSES BETWEEN LINTEL AND TIE BEAM POURED SOLID ARE ACCEPTABLE A SINGLE SOLID FILLED LINTEL, OF THE SAME LENGTH MAY BE USED TO SEPARATE DOORS AND WINDOWS FROM TRANSOM ABOVE. TOP PRECAST TO BE SIZED PER PLAN vu• 2500 PSI CONC, FILL (CONCRETE PLACED IN SEE SCHEDULE FOR ST AND TIE BEAM ABOVE -STD 180D HOOK @ EA( STIRRUP W/2 1/2' LE PAST BEND. (TYP) —7/32' STIRRUPS AT (TIED OR WELDED) NOTES, L MINIMUM COVERAGE OF S_ 2, MIN, BEARING REQUIRED 1 7 sie' U -TYPICAL LINTEL SECTION PRECAST CONCRETE ,11111 � 111�11111�1 OEM I 1 1 1 1 1 1 :111111111111 8' CHU— # 5 VERTICAL GROUTED CELLS PER PLAN WIND❑W RES, FOR RETRO FIT FILLED CELL ATTACH VERTICAL STEEL AT TOP TO EXISTING BOND BEAM MIN. 6" EMBEDMENT WITH EPDXY. ST. POURED TIE NEW LINTEL NO FILL, NO STEEL II OPEN BLOCK TO ALLOW NEW CELL FILLING EPDXY DOWEL TO EXISTING BEAM, MIN. 4" EMBEDMENT LAP NEW STEEL 25" ALL LOCATIONS MIN. "OPENINGS MAY VARY IN WIDTH" OPEN BLOCK TO ALLOW DOWEL INSTALATION. CLOSE UP WITH FORM AND FILL CELL TO EXISTING BOND BEAM. EPDXY DOWEL TO EXISTING FOOTING, MIN. 4" EMBEDMEN CONC, SILL BELOV ALUNRIM WINDOW PRESSURE TREATED WINDOW BUCK MCHI MASONRY VITH 1/4 TAPCONS 24' QC, (SEE MANUFACTURER CONCRETE SILL BELT JAMB 8" CML DOWEL _ # 5 RE -BAR @ 30" LENGTH MIN. EPDXY = SIMPSON "SET" OR EQ. HIGH STRENGTH EPDXY. RETR❑-FIT CELL DETAIL EXIST. L-/\ 1 J 1 11 V V I V V I L I N EXISTING C.B. WALL SECTI❑N SCALE;3/4'=1'-0' REVIEWED FOR CODE COMPL: PLANS EXAMINER DATE aANFORD BUILDING DIVISION A PERMIT ISSUED SHALL BE CONSTRUED TO BE A LICENSE TO PROCEED WITH THE WORK AND NOT AS AUTHORITY TO VIOLATE, CANCEL, ALTER OR SET ASIDE ANY OF THE PROVISIONS OF THE TECHNICAL CODES, NOR SHALL ISSUANCE OF A PERMIT PREVENT THE BUILDING OFFICIAL FROM THEREAFTER REQUIRING A CORRECTION OF ERRORS IN PLANS, CONSTRUCTION OR VIOLATIONS OF THIS CODE WINDOW DESIGN PRESSURE REQUIREMENTS ALL SIZES & CONFIGURATIONS POSITIVE PRESSURE OF 25.9 p.s.f. NEGATIVE PRESSURE OF 34.7 p.s.f. LEGAL DESCRIPTI❑NI LOT 40, REPLAT OF GROVEVIEW VILLAGE FIRST ADDITION, ACCORDING TO THE PLAT THEREOF, AS RECORDED IN PIAT BOOK 26, PAGE 4-6, OF THE PUBLIC RECORDS OF SEMINOLE COUNTY, FLORIDA. CONSTRUCTION TYPE: V -B WIND SPEED = 139 MPH V -ULT RISK FACTOR = CATEGORY II WIND EXPOSURE = CATEGORY B INTERNAL PRESSURE COEFF.= .18 COMPONENTS AND CLADDING ROOF= +20.3 / -83.1 WALL= +35.3 / -47.2 DESIGN REQUIREMENTS LIVE LOADS ROOF - 20 PSF FLOORS, STAIRS= 40 PSF DECKS, BALCONY = 60 PSF ATTIC: UNIHABITABLE, WITHOUT STORAGE= 10 PSF WITH STORAGE= 20 PSF NOTE: THIS PROJECT HAS BEEN DESIGNED IN ACCORDANCE WITH 5th. EDITION FLORIDA BUILDING CODE 2014 RESIDENTIAL DRAFT, SECTION R301 DESIGN CRITERIA AND ASCE 7-10 TO THE BEST OF MY KNOWLEDGE THESE CONTRACT DOCUMENTS PREPARED UNDER MY DIRECT SUPERVISION, COMPLY WITH THE APPLICABLE MINIMUM CODE REQUIREMENTS AND THE SAFETY STANDARDS AS DETERMINED BY THE LOCAL AUTHORITY IN ACCORDANCE WITH CHAPTERS 553 AND 633 OF THE FLORIDA STATUTES ALL ALTERATIONS OR REPAIRS TO EXISl'ING MEET OR EXCEED 2014 FLORIDA BUILDING CODE EXISTING. 1 REVISIONS 2 3 4 5 6 7 N w00 v) o tY Z w ( w w Q Z W Y Z W W � w► i vi g N "� 113:� w 0- LLJ Z w® n C�� z S 2O W LL1 � nC�I m z I _ N Z O ,n ,n J J 0 1 j� _ (_ L �x ~� 0 n O OZ) c0 O z :2 LLI Y Z 0 Q U Q � J z M < w r- 0 04 Z BOLL W 3 O O ILL A O Z Z M V) 3 r w 3 0 Of Ld z to 0 �H E o � r :0 d co 0 L10) COO M o M0 a ,{{ CV M 0 F 0 0 ^� IL o o QLu e �1 r W U J v LLI O o0 �� CID '— 0 Z Q) w U z L7 w 0 DRAWN: N.A. REVISED: K. E. SCALE: 1 /4"=1 '-0" DATE: 08-16-15 SHEET 1 1 0f 18"x24"