Loading...
840 Rosalia Dr (a)IBY:OING IVE% 8 2011 CI Y OF SANFORD E PREVENTION PERMIT APPLICATION Application No: 010 1cf 11 Documented Construction Value: $ S'A / Job Address: l A i Parcel ID: Historic District: Yes o Zoning: O Description of Work: 04(=l P, '00-ores Plan Review Contact Person: 90gele— Title: Phone: L10? '11,1Q30 6 Fax: E-mail: n Property Owner Information Name 9 U /d' Al e' Street: gb3r egg ,0 City, State Zip: UU l e-4 EP Phone: Z/ U7 C a O 12. / S Resident of property? : %-10 Contractor Informatinn Name Ow"g:54g, /1 , Street: Ok6 Clxobiw On Lj City, State Zip:. r-P ; = 7 7 Phone: 91.167306Fax: State License No.: C F A(o 31-/1/ Architect/ Engineer Information Name: Phone: Street: City, St, Zip: Bonding Company: Address: Building Permit O Square Footage: No. of Dwelling Units: Electrical D Fax: E- mail: Mortgage Lender: Address: PERMIT INFORMATION Construction Type: Flood Zone: New Service — No. of AMPS: Mechanical 0 (Duct layout required for new systems) No. of Stories: Plumbing O New Construction - No. of Fixtures: Fire Sprinkler/Alarm 0 No. of heads: Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all -work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be;done„in,compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE: In addition to the requirements of this permit, there may be additional restrictionsapplicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee. A copy of the executed contract is required in order to calculate a plan review charge. If the executed contract is not submitted, we reserve the right to calculate the plan review fee based on past permit activity levels. Should calculated charges exceed the documented construction value when the executed contract is submitted, credit will be applied to your permit fees when the permit is released. Signature Print Owner/Agent's Name Signature of Notay/State of Florida Date Signature of ntractor/Agent Date UQ ame 71Z Date Florida Date Owner/ Agent is Personally Known to M11,qProduced ID De, Type of ID APPROVALS: ZONING: 1140f 8-HI UTILITIES: ENGINEERING: COMMENTS: bpi 1„ rc(iarC Jt 5t d,r I I: Contractor/ Agent is Produced ID N Rev 11.08 SIDE -HINGED METAL -EDGE STEEL DOOR UNIT 6'-8" DOUBLE DOOR WITH / WITHOUT SIDELITES LFY_RAL NOTES EVALUATED FOR USE IN LOCATIONS ADHER14C -0 THE FLORIDA BUILDING CODE AND WHERE PRESSURE PEOUIREMENTS AS DETERMINED BY ASCE 7. MINIMUM DESICN LOADS FOR BUILDINGS AND OTHER STRUCTURES. O C•CES NOT EXCEED THE DESICN PRESSURES LISTED 2 HUPRWANE >ROTECTNE SYSTEM (SHUTTFFS) IS NOT REQUIRED ON OPAOUE PANELS. BUT IS REOUIRED ON GLAZED SIDELTES 1 3 PCLYRETHANE CORE SMOK DEVE:OPEFLAME INSPREADPER X DEXO0 ANDASiM E84A PLASTICS TESTING OF UTE FRAME MATERIAL - TEST DESCRIPTION DESIGNATION RESLLT SELF .GNIImomTION TEuP ASTM 0 W 13® ®® ®® u . 00 00: 00 00 OSINGLE DOOR UNIT DOUBLE DOOR UNIT TABLE OF CONTENTS SHEET p DESCRIPTION I TYPICAL ELEVA- IONS & :.ENERAL NCTES 2 AV.-.H!? RIAf. 10CATIONS & DLIAILS 31AvCHOR..C. LQCATIONS & DETAILS SINGLE DOOR. UNIT WITH SIDFLITF U-) a 00 lag' Max OvERALL FfiAVE WDIH Cr o U 21" MAX 36. 375' MAX. — PANEL v/IDTH _ 37.5" MAX _ Q G W/ASTRAGAL I FRAME WIDTH I Q ' O I I US 2 W J Z 0) r3 Ci 1 1.1 t-. J isnI I i I gW o a88 e u a ypzyj- 0 0 SINGLE DOOR UNR WITH SIDE, ITE D')uRI F DOOR UNIT w/SIDELITES E It A [ EI - SINGLE DOOR UNIT V//SIDELITES DOUBLE DOOR UNIT W/SIDELITES DESIGN PRESSURE RATING WHERE WATER INFILTRATION PERFORMANCE IS REOuIRED TO BE 15% OF DESIGN PRESSURE CONFIC MAX WIDTH INSWING I OUTSWING INSWING OUTSWINC 4< 37.5 760 76C +763 76C 19.0 -19.0 550 -550 4 '550+550 - 050 +550 -55.0 i90 -19.0 55.0 -550 OX or AL' 75 550 650 +550 SS.0 i90 -19.0 550 OYO 112.5 r530 190 -19.0 55.0 -550 DXti0 tl5 550 5.0 1+55.0 55C t190 -i9.0 55.O -510 v 12-lI- Ip KURT i3ALThAZOR FLORIDA P E 1-96533 d aN T. S ec $w5 B. aG no M4-- L0132-0 I I o . 3 RATE OF BURNING 1929 740 'F > 650 'F ASTN 0635 b" SF.E DI: IAIL 6 3.. 3" I n SEE DETAII c" A n 3" 0 a SEE DETAIL a D" D W a aj I I N 10 8 x 2-1/2" # 10 x 2\ #8 x 2-1/2" 10 x 3/4" s • 8 , 2-1/2" #9 x 314" O #;0 x 3/4" I. //9 x 3/4" L{10 x 2" DETAIL "E" ASTRAGAL ULIAIL "C" ATTACH ASTRAGAL RETAINER BOLT DETAIL "D" STRIKE PLATE TO FRAME AS SHOWN. t 375! i INSWII,IG 1 HRESHOLU 0 962" 1 OUTSWING IHNLjHOLU 9Evxn v ; 1h1E Rwiesn. "'. a I ,c 6" EE DETAIL C" 6- ASTRAGAL RETAINER BOLT HOLE MUST BE DRILLED THROUGH THE THRESHOLD & INTO THE STRUCTURE DEEP ENOUGH FOR A ".375" THROW DETAIL "I"' .ASTRAGAI. EO90U3iAL\ ALUM. STEEL OP BUM SPACER l6 x 1-1/2" PRS 11 VOw m-, E_uFLh7FR16RINIER0_ R TYPICAL GLAZING DETAIL a u-) Do 0 U p Q J 2 n C cc U ui p u_ Z U Cif O LJS III I 11-1 WE 7/ 25/05 S.0 F NT S Cw0 0• SWS K B1 PZ:wlrri, W CwG-tq- F10139-OS 54ET _ OF 3 SFF DFFAIl C" SHT. 2 ATTACHMENT DEIAIL 1. ANCHOR ANALYSIS FOR LOADING CONDITIONS PREPARED, SIGNED AND SEALED BY LUIS R. LOAAS. PE FLORIDA #62514) WITH THE LOWEST (LEAST) FASTENER RATING FROM THE DIFFERENT FASTENERS BEING CONSIDERED FOR USE. ,IAMB. HEAD. ANC THRESHOLD FASTENERS ANALYZED FOR THIS UNIT INCLLDF. 10 WOOD SCREWS OR 3/16" TAPCONS. A PHYSICAL SHIM MUST BE PLACED IN SHIM SPACE A— EACH ANCHOR LOCATION. 2. THE WOOD SCREW SINGLE SHEAR DESIGN VALUES COME FROM ANSI/AF&PA NDA FOR SOUTHERN PINE LUMBER AND ACHEIVEMCNT OF 1-1/2" MINIMUM EMBEDMENT THE TAPCON MUST ACHIEVE MINIMUM EMBEDMENT OF '-1/4". 3. WOOD BUCKS BY OTHERS MUST 3E .ANCHORED PROPERLY TO TRANSFER LOADS TO STRUCTURE. 1. MINIMUM DESIGN VALUE STRENGTH OF ANCHORS 171 LBS. U a SEE DETAIL D" SHT. 2 rJ a 9 0W a K N 1.50" MIN 10 I 311 I r. I I r I II I I II I I I I 0 a 0. J a 0W I II c I II II e II I W e C 6 3-6 3, 6.. HARFIWARF SCH17111]I F 1. KWIKSET SERIES 400 GRADE 3 CYLINDRICAL LATCH AND SERIES 980 GRADE 1 DEADLOCK HARDWARE TO BE INSTALLED AT 5-1/2" CENTERLINE. 2 4" a a" FUL_ MORTISE BJTT HINGES MAX HIM TYPICAL WOOD BUCK ANCHOF. INSTALLATION 1 25' MIN - t 0 2. MAXSHIN CL tK TYPICAL MASONRY ANCHOR INSIALLATION U-) cc co 0 0Uto Z J O cr O 0 U_ z CL NUOF' 1 e,.mr N T.S c. ey. SWS cNK er 01.12-05 of 3 Florida Building Code Online http://www.floridabuilding.org/pr/pr app_dil.aspx?p:u:m=w... 0, unity Af ifa irs: =W--T r SCIS ltoo is i Lop In I User Registration ' Mot Topics ' Subml Surcharge Slats & Facts Publications i FBC Staff SCIS Site Map Links Search i,v Product Approval 1l yy USER Public User Producl App oval Menu > Pioducl Or Applicalion Soarch > Applicotion List > Application Detail FL A FL4940-R2 Application Type Revision Code Version 2007 Application Status Approved Approved by DCA. Approvals by DCA shall be reviewed and ratified by the POC andfor the Commission it necessary. Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Ouality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Certification Agency Validated By Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By I of 3 Masonite International One North Dale Mabry Suite 950 Tampa, FL 33609 615) 441.4258 sschreiber@masonite.com Steve Schreiber sschreiber@masonite.com Exterior Doors Swinging Exterior Door Assemblies Certification Mark or Listing National Accreditation & Management Institute, National Accreditation & Management Institute, Standard TAS 201 TAS 202 TAS 203 Year 1994 1994 1994 07/27/201 1 03:32 PM Florida Building Code Online http://www. flondabui lding. org/pr/pr_app_dt I. aspx?past»= w... Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Method 1 Option A 12/16/2010 12/16/2010 12/22/2010 summary or vroaucts FL # Model, Number or Name 4940.1 Metal -edge Steel Side -Hinged Door Units Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +76.0/-76.0 Other: Evaluated for use in locations adhering to the Florida Budding Code including the High Velocity Hurricane Zone, and where pressure requirements as determined by ASCE 7, do not exceed the design pressures listed 3'-0" x F-8" max nominal size. Max DP = +/- 76.0. When large missile impact resistance is required, hurricane protective system is NOT required See installation drawing DWG-MA-FLO132-05 for additional information. Description 6'r8" Opaque I/S and O/S Single Door Certification Agency Certificate FL4940 R2 C CAC N1006115-R3 PDF Quality Assurance Contract Expiration Date 12/31/2014 Installation Instructions FL4940 R2 11 FL0132.pdf Verified By. National Accreditation & Management Institute, Created by Independent Third Party* Evaluation Reports FL4940 R2 AE 504A.pdf Created by Independent Third Party, Yes 4940.2 I Metal -edge Steel Side -Hinged Door 6'-8" Opaque I/S and O/S Door w/ or w/o Sidelites Units Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +55 0V-55.0 Other: Evaluated for use in locations adhering to the Florida Building Code including the High Velocity Hurricane Zone, and where pressure requirements as determined by ASCE 7, do not exceed the design pressures listed. 12'-0" x 6'-8" max nominal size. Max DP = +/- 55.0. When large missile impact resistance is required, hurricane protective system is NOT required on opaque panels, but is required on glazed panels. See installation drawing DWG-MA-FLO132-05 for additional information. Certification Agency Certificate FL4940 R2 C CAC N1006115-R3 PDF Quality Assurance Contract Expiration Date 12/31/2014 Installation Instructions FL4940 R2 II FL0132.pdf Verified By- National Accreditation & Management Institute, Created by Independent Third Party: Evaluation Reports FL4940 R2 AE 502A pdf Created by Independent Third Party: Yes 4940.3 I Metal -edge Steel Side -Hinged Door 8'-0" Opaque I/S and O/S Door w/ or w/o Sidelites Units Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +48 31-48.3 Other: Evaluated for use in locations adhering to the Florida Budding Code including the High Velocity Hurricane Zone, and where pressure requirements as determined by ASCE 7, do not exceed the design pressures listed. IZ-0" x 8'-0" max nominal size. Max DP = +/- 48.3. When large missile impact resistance is required, hurricane protective system is NOT required on opaque panels, but is required on glazed panels See installation drawing Certification Agency Certificate FL4940 R2 C CAC N1006115-R3 PDF Quality Assurance Contract Expiration Date 12/31/2014 Installation Instructions FL4940 R2 II FLO133 Ddf Verified By. National Accreditation & Management Institute, Created by Independent Third Party: Evaluation Reports FL4940 R2 AE 501A.Ddf Created by Independent Third Party: Yes 2 of 3 07/27/201 1 03:32 PM Florida Building Code Online http://www.floiidabuilding.oi-g/pr/pr app_dtl.acpx?param=w... DWG-MA-FLO133.05 for additional Information. 4940 4 Metal -edge Steel Side -Hinged Door 6'-8" Glazed I/S and O/S Door w/ or w/o Sidelites Units Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL4940 R2 C CAC N1006115-R3.PDF Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: No 12/31/2014 Design Pressure: +50.5i-50.5 Installation Instructions Other: Evaluated for use in locations adhering to the Florida FL4940 R2 II FLO134 cdf Building Code including the High Velocity Hurricane Zone, and Verified By' National Accreditation & Management Institute, where pressure requirements as determined by ASCE 7, do not Created by Independent Third Party. exceed the design pressures listed. 17-0" x 6-8" max nominal Evaluation Reports size. Max DP = +/- 50.5 When large missile Impact resistance is FL4940 R2 AE 502A Ddl required, hurricane protective system is required. See installation Created by Independent Third Party: Yes drawing DWG-MA-FLO134-05 for additional information. 49405 Metal -edge Steel Side -Hinged Door 8'-0" Glazed I/S and O/S Door Units Limits of Use Certification Agency Certificate Approved for use In HVHZ: Yes FL4940 R2 C CAC N1006115-R3 PDF Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: No 12/31/2014 Design Pressure: +43.0/45.0 Installation Instructions Other: Evaluated for use in locations adhering to the Florida FL4940 R2 II FI-0135.Ddf Building Code including the High Velocity Hurricane Zone, and Verified By. National Accreditation & Management Institute, where pressure requirements as determined by ASCE 7, do not Created by Independent Third Party: exceed the design pressures listed. 6-0" x 8'-0" max nominal Evaluation Reports size Max DP = +43.0 / -45.0. When large missile impact FL4940 R2 AE 501A.Ddl resistance is required, hurricane protective system is required. Created by Independent Third Party: Yes See installation drawing DWG-MA-FLO135.05 for additional information. Baok Nest Department or Community Attairs Florida Building Code Online Codes and Standards 2555 Shumard Oak Boulevard Tallahassee, Florida 32399.21W 8W) 467.1824. Fax (8W) 414.8436 O 2DDD•2010 The State of Florida All nphls reserved Privacy Statement I CoDyriphl Statement IAccessibility Statement I Pluo-in Software I Customer Service Survey I Contact Us Product Approval Accepts: 1- M- Sl`l'llrll V tlhI It rC Wrrfla^" Trustee r•r.. r 3 of 3 07/27/201 1 03:32 PM