800 Marbella Ln - Clubhouse (former 2205 W Seminole Blvd) (Bldg A) 17-1580-2Revision City of Sanford Response to Comments SEP 12 IN Building & Fire Prevention Division Ph: 407.688.5150 Fax: 407.688.5152 Email: building@sanfordfl.gov Permit # /-T ' SV Submittal Date Project Ad ss: r) a o S y `e b U C h Contact: Ph:j Email: Trades encompassed in revision: Building Plumbing Electrical Mechanical Life Safety Waste Water Department Utilities Waste Water Planning Engineering Fire Prevention Fax: General description of revision: ROUTING INFORMATION Building Approvals r UNIVERSAL ENGINEERING SCIENCES Consultants In: Geotechnical Engineering • Environmental Sciences Geophysical Services • Materials Testing • Threshold Inspection Building Code Administration, Compliance Inspection & Plan Review 3532 Maggie Blvd, Orlando, FL 32811 - P: 407.423.0504 - F: 407.423.3106 UES Project No.: 0110.1800758.0000 Date Typed: March 13, 2019 Construction Materials Testing Services FIELD AND LABORATORY REPORT COVER PAGE Client: The Spanos Corporation 2701 N. Rocky Point Drive, Suite 100 Tampa, FL 33607 Project: Lake Monroe Apartments, Materials Testing US 92 & West 1st Street, Sanford, Seminole County, FL 32771 As requested, Universal Engineering Sciences, Inc. (LIES) representative(s) performed construction materials testing and/or field inspection services on the above project. Testing results and/or inspection observations are reported on the attached sheets. The contents of this package are summarized below: Scope of Work Work Order No. Date Type of Report 9439734-1 03/01/2019 Grout Prism Test Specimens Report 9441234-1 03/05/2019 4" x 8" Cylinder Test Specimens Report 9441234-2 03/05/2019 4" x 8" Cylinder Test Specimens Report 9441234-3 03/05/2019 4" x 8" Cylinder Test Specimens Report 9441234-4 03/05/2019 4" x 8" Cylinder Test Specimens Report 9441234-5 03/05/2019 4" x 8" Cylinder Test Specimens Report 9441234-6 03/05/2019 4" x 8" Cylinder Test Specimens Report 9441503-1 03/12/2019 In -Place Density Test Report 9441504-1 03/13/2019 In -Place Density Test Report 9441504-2 03/13/2019 In -Place Density Test Report We hope this information is sufficient for your immediate needs. If you have any questions, please do not hesitate to contact the undersigned or Rosie Housein (extension 23078). Sincerely, Universal Engineering Sciences, Inc. Certificate of Authorization No. 00000549 Fred J. Schmalzer 2019.03.15 08:36:33-04'00' Fred J. Schmalzer, P.E. Vice President - Construction Services STATE OF FLORIDA Professional Engineer No. 38818 For the mutual protection of Universal's clients, the general public, and ourselves, our reports are submitted as the confidential property of our clients. Accordingly, authorization for reliance upon, or publication of, all or portions of this report is reserved pending our written approval. Revised May 2015 UNIVERSAL Project No: 94397 4-1 CTReportNo.: 9439734-1 CT 030119 9439734 ENGINEERING SCIENCES WorkoLab rNo.: 119M936-C Consultants In: Geotechnical Engineering • Environmental Sciences Date 1st Issue: March 13, 2019 Geophysical Services • Materials Testing • Threshold Inspection EDBuildingCodeAdministration, Compliance Inspection & Plan Review 3532 Maggie Blvd, Orlando, FL 32811 - P: 407.423.0504 - F: 407.423.3106 Compressive Strength of Grout Prism Test Specimens ASTM C-1019) Client The Spanos Corporation 2701 N. Rocky Point Drive, Suite 100, Tampa, FL 33607 Project Lake Monroe Apartments, Materials Testing US 92 & West 1st Street, Sanford, Seminole County, FL 32771 Structural Element: Cell Fill Sample Location: Building C (Permit Number 17-1582) - Sampled at Elevator Shaft/ Top Lift/ 4th Floor Set# 1 of 1 Sample From: Concrete Truck General Information General Contractor: E.W. Young Construction Subcontractor: Supplier: Maschmeyer Concrete Truck No.: 276 Ticket No.: 1850043 Mix Design: 30550000 Admixture: Nis Sample By: Adrian Garcia On 03/01/2019 Specified Strength / Sampling Times Specified Strength: 3000 psi @ 28 days Mix Design Strength: 3000 psi @ 28 days Water Added at Site: N/A Time Batched: 12:20 PM Time Sampled: 1:20 PM Weather Condition: Partly Cloudy Field Test Results At Lab On or Before: 03/06/2019 Placement Information Truck Load: 2.00 cu yds. Cumulative Quantity: 2.00 cu yds. Total Placement for the Day: 2.00 cu yds. Air Content: N/A Slump: 8.75 inches Ambient Temp: 81 °F I Concrete Temp: 85 OF Unit Weight: NIA Results of Laboratory Testing Test Results Date Tested Age Days Type Of Fracture Actual Dimen. 1 in) Actual Dimen. 2 in) Avg. Dimen. in) Test XSect. Area ( in2) Max Compressive Load ( Ibs) Test Compressive Strength( psi) Average psi) 1 03/11/2019 10 3.31 3.34 3.33 11.06 29,935 2,710 2 03/29/2019 28 3 03/29/2019 28 4 03/29/2019 28 1 - Remarks Grout Prisms are tested at seven (7) days to get an early indication of the potential strength of the concrete, but the seven (7) day results are not to be used for concrete acceptance. When the compressive strength of the concrete has reached 70% of the specified strength, it is a reasonable practice to use this as an indication that 100% of the specified strength will be attained by twenty-eight (28) days. Note Test Results represent the Structural Element specified If an air test was not completed, that deviates from C31 procedure Tested in Lab to C39 Cured in C-511 Test Not performed per C-1019, Grout Boxes were used To establish a mutual protection to Universal's clients, the Public and ourselves, all reports are submitted as confidential property of ourclients and authorization for publicationof statements, conclusions or extracts from or regarding Universal's reports is reserved pending our written approval. This report shall not be reproduced, except in full, without the written approval of UniversalEngineering Sciences. 1 of 1 Revised May 2018 UNIVERSAL ENGINEERING SCIENCES Consultants In: Geotechnical Engineering • Environmental Sciences Geophysical Services • Materials Testing • Threshold Inspection Building Code Administration, Compliance Inspection & Plan Review 3532 Maggie Blvd, Orlando, FL 32811 - P: 407.423.0504 - F: 407.423.3106 Compressive Strength of 4" x 8" Cylinder Test Specimens ASTM C-39) Client The Spanos Corporation 2701 N. Rocky Point Drive, Suite 100, Tampa, FL 33607 Project Lake Monroe Apartments, Materials Testing US 92 & West 1st Street, Sanford, Seminole County, FL 32771 Project No: 0110.1800758.0000 ReportNo.: 9441234-1 CT 030519 WorkorderNo.: 9441234 Lab No.: 19N017-C Date 1st Issue: March 13, 2019 Structural Element: Footing Sample Location: Building Slab D (Permit Number 17-1583) - Sampled at 15Ft N 10 Ft E on the E Footing Set# 1 of 6 Sample From: Concrete Truck General Information General Contractor: E.W Young Construction Subcontractor: Supplier: Maschmeyer Concrete Truck No.: 607 Ticket No.: 1850100 Mix Design: 30090000 Admixture: Nis Sample By: Fernando Montalvo On 03/05/2019 At Lab On or Before: 03/06/2019 Specified Strength / Sampling Times Specified Strength: 3000 psi @ 28 days Mix Design Strength: 3000 psi @ 28 days Water Added at Site: N/A Time Batched: 2:56 AM Time Sampled: 3:10 AM Weather Condition: Partly Cloudy Field Test Results Placement Information Truck Load: 10.00 cu yds. Cumulative Quantity: 10.00 cu yds. Total Placement for the Day: 280.00 cu yds. Air Content: N/A Slump: 8.50 inches Ambient Temp: 62 °F I Concrete Temp: 77 OF Unit Weight: N/A Results of Laboratory Testing Test Results Date Tested Age Days Type Of Fracture Actual Dimen.1 in) Actual Dimen.2 in) Avg. Dimen. in) Test X-Sect. Area (in') Max Compressive Load (Ibs) Test Compressive Strength(psi) Average psi) 1 03/12/2019 7 5 4.00 4.01 4.01 12.63 26,340 2,090 2 04/02/2019 28 3 04/02/2019 28 4 04/02/2019 28 5*H* 04/02/2019 28 Remarks Cylinders are tested at seven (7) days to get an early indication of the potential strength of the concrete, but the seven (7) day results are not to be used for concrete acceptance. When the compressive strength of the concrete has reached 70% of the specified strength, it is a reasonable practice to use this as an indication that 100% of the specified strength will be attained by twenty-eight (28) days. Note H*- Hold Cylinder -*D*- Defective Cylinder, Un-testable -*E*- Excluded From Average Note Test Results represent the Structural Element specified If an air test was not completed, that deviates from C31 procedure Sampled per ASTM C-172 - Yes Air Content Performed per ASTM C-173 or C-231 - No Unit Weight Performed per ASTM C-138 - N/A Slump Performed per ASTM C-143 - Yes Concrete Temperature Performed per ASTM C-1064 - Yes Molded per C-31 - Yes Initially Cured per ASTM C-31 - Unknown Capped in Lab to ASTM C-1231 Cured & Tested in Lab per ASTM C-31 & C-39 - Yes This Form Conforms With ASTM C-39 To establish a mutual protection to Universal's clients, the Public and ourselves, all reports are submitted as confidential property of our clients and authorization for publication ofstatements, conclusions or extracts from or regarding Universal's reports is reserved pending our written approval. This report shall not be reproduced, except in full, without the written approval of Universal Engineering Sciences. 1 of 1 Revised May 2018 UNIVERSAL ENGINEERING SCIENCES Consultants In: Geotechnical Engineering • Environmental Sciences Geophysical Services • Materials Testing • Threshold Inspection Building Code Administration, Compliance Inspection & Plan Review 3532 Maggie Blvd, Orlando, FL 32811 - P: 407.423.0504 - F: 407.423.3106 Compressive Strength of 4" x 8" Cylinder Test Specimens ASTM C-39) Client The Spanos Corporation 2701 N. Rocky Point Drive, Suite 100, Tampa, FL 33607 Project Lake Monroe Apartments, Materials Testing US 92 & West 1st Street, Sanford, Seminole County, FL 32771 Project No: 0110.1800758.0000 ReportNo.: 9441234-2 CT 030519 WorkorderNo.: 9441234 Lab No.: 19NO18-C Date 1st Issue: March 13, 2019 Structural Element: Footing Sample Location: Building Slab D (Permit Number 17-1583) - Sampled at 10Ft N 10 Ft W on the N Footing Set# 2 of 6 Sample From: Concrete Truck General Information General Contractor: E.W Young Construction Subcontractor: Supplier: Maschmeyer Concrete Truck No.: 646 Ticket No.: 1850105 Mix Design: 30090000 Admixture: Nis Sample By: Fernando Montalvo On 03/05/2019 At Lab On or Before: 03/06/2019 Specified Strength / Sampling Times Placement Information Specified Strength: 3000 psi @ 28 days Truck Load: 10.00 cu yds. Mix Design Strength: 3000 psi @ 28 days Cumulative Quantity: 60.00 cu yds. Water Added at Site: N/A Total Placement for the Day: 280.00 cu yds. Time Batched: 3:26 AM Time Sampled: 3:55 AM Weather Condition: Partly Cloudy Field Test Results Air Content: N/A Slump: 6.50 inches Ambient Temp: 621FJ Concrete Temp: 72 OF Unit Weight: N/A Results of Laboratory Testing Test Results Date Tested Age Days Type Of Fracture Actual Dimen.1 in) Actual Dimen.2 in) Avg. Dimen. in) Test X-Sect. Area (in') Max Compressive Load (Ibs) Test Compressive Strength(psi) Average psi) 1 03/12/2019 7 5 4.00 4.01 4.01 12.63 26,880 2,130 2 04/02/2019 28 3 04/02/2019 28 4 04/02/2019 28 5'H' 04/02/2019 28 Remarks Cylinders are tested at seven (7) days to get an early indication of the potential strength ofthe concrete, but the seven (7) day results are not to be used for concrete acceptance. When the compressive strength of the concrete has reached 70% of the specified strength, it is a reasonable practice to use this as an indication that 100% of the specified strength will be attained by twenty-eight (28) days. Note H*- Hold Cylinder -`D*- Defective Cylinder, Un-testable -*E*- Excluded From Average Note Test Results represent the Structural Element specified If an air test was not completed, that deviates from C31 procedure I j., L'1 1 Sampled per ASTM C-172 - Yes Air Content Performed per ASTM C-173 or C-231 - No L Unit Weight Performed per ASTM C-138 - N/A Slump Performed per ASTM C-143 - Yes Concrete Temperature Performed per ASTM C-1064 - Yes F-7] Molded per C-31 - Yes Initially Cured per ASTM C-31 - Unknown Capped in Lab to ASTM C-1231 p w , Cured & Tested in Lab per ASTM C-31 & C-39 - Yes This Form Conforms With ASTM C-39 To establish a mutual protection to Universal's clients, the Public and ourselves, all reports are submitted as confidential property ofour clients and authorization for publication of statements, conclusions or extracts from or regarding Universal's reports is reserved pending our written approval. This report shall not be reproduced, except in full, without the written approval of Universal Engineering Sciences. 1 of 1 Revised May 2018 UNIVERSAL ENGINEERING SCIENCES Consultants In: Geotechnical Engineering • Environmental Sciences Geophysical Services • Materials Testing • Threshold Inspection Building Code Administration, Compliance Inspection & Plan Review 3532 Maggie Blvd, Orlando, FL 32811 - P: 407.423.0504 - F: 407.423.3106 Compressive Strength of 4" x 8" Cylinder Test Specimens ASTM C-39) Client The Spanos Corporation 2701 N. Rocky Point Drive, Suite 100, Tampa, FL 33607 Project Lake Monroe Apartments, Materials Testing US 92 & West 1 st Street, Sanford, Seminole County, FL 32771 Project No: 0110.1800758.0000 ReportNo.: 9441234-3 CT 030519 WorkorderNo.: 9441234 Lab No.: 19NO19-C Date 1st Issue: March 13, 2019 Structural Element: Slab on Grade Sample Location: Building Slab D (Permit Number 17-1583) - Sampled at 10Ft N 15 Ft W on the NW Coner Of Slab Set# 3 of 6 Sample From: Concrete Truck General Information General Contractor: E.W Young Construction Subcontractor: Supplier: Maschmeyer Concrete Truck No.: 606 Ticket No.: 1850111 Mix Design: 30090000 Admixture: Nis Sample By: Fernando Montalvo On 03/05/2019 At Lab On or Before: 03/06/2019 Specified Strength / Sampling Times Specified Strength: 3000 psi @ 28 days Mix Design Strength: 3000 psi @ 28 days Water Added at Site: N/A Time Batched: 4:05 AM Time Sampled: 4:22 AM Weather Condition: Partly Cloudy Field Test Results Placement Information Truck Load: 10.00 cu yds. Cumulative Quantity: 110.00 cu yds. Total Placement for the Day: 280.00 cu yds. Air Content: N/A Slump: 6.00 inches Ambient Temp: 62 °F I Concrete Temp: 74 °F Unit Weight: N/A Results of Laboratory Testing Test Results Date Tested Age Days Type Of Fracture Actual Dimen.1 in) Actual Dimen.2 in) Avg. Dimen. in) Test XSect. Area (in') Max Compressive Load (lbs) Test Compressive Strength(psi) Average psi) 1 03/12/2019 7 5 4.00 4.01 4.01 12.63 23,960 1,900 2 04/02/2019 28 3 04/02/2019 28 4 04/02/2019 28 5"H" 04/02/2019 1 28 Remarks Cylinders are tested at seven (7) days to get an early indication of the potential strength of the concrete, but the seven (7) day results are not to be used for concrete acceptance. When the compressive strength of the concrete has reached 70% of the specified strength, it is a reasonable practice to use this as an indication that 100% of the specified strength will be attained by twenty-eight (28) days. Note H*- Hold Cylinder `D*- Defective Cylinder, Un-testable -*E*- Excluded From Average Note Test Results represent the Structural Element specified If an air test was not completed, that deviates from C31 procedure Sampled per ASTM C-172 - Yes Air Content Performed per ASTM C-173 or C-231 - No Unit Weight Performed per ASTM C-138 - N/A Slump Performed per ASTM C-143 - Yes Concrete Temperature Performed per ASTM C-1064 - Yes Molded per C-31 - Yes Initially Cured per ASTM C-31 - Unknown Capped in Lab to ASTM C-1231 Cured & Tested in Lab per ASTM C-31 & C-39 - Yes This Form Conforms With ASTM C-39 To establish a mutual protection to Universal's clients, the Public and ourselves, allreports are submitted as confidential property ofour clients and authorization for publication of statements, conclusions or extracts from or regarding Universal's reports is reserved pending our written approval. This report shall not be reproduced, except in full, without the written approval of Universal Engineering Sciences. 1 of 1 Revised May 2018 Project No: 0110.1800758.0000UNIVERSALReportNo.: 9441/2344 CT 030519 9441234 ENGINEERING SCIENCES WorkoLab rNo.: 119N020-C Consultants In: Geotechnical Engineering • Environmental Sciences Date 1st Issue: March 13, 2019 Geophysical Services • Materials Testing • Threshold Inspection EDBuildingCodeAdministration, Compliance Inspection & Plan Review 3532 Maggie Blvd, Orlando, FL 32811 - P: 407.423.0504 - F: 407.423.3106 Compressive Strength of 4" x 8" Cylinder Test Specimens ASTM C-39) Client The Spanos Corporation 2701 N. Rocky Point Drive, Suite 100, Tampa, FL 33607 Project Lake Monroe Apartments, Materials Testing US 92 & West 1 st Street, Sanford, Seminole County, FL 32771 Structural Element: Slab on Grade Sample Location: Building Slab D (Permit Number 17-1583) - Sampled at 10Ft E 5 Ft S on the SE Coner Of Slab Set# 4 of 6 Sample From: Concrete Truck General Information General Contractor: E.W Young Construction Subcontractor: Supplier: Maschmeyer Concrete Truck No.: 602 Ticket No.: 1850116 Mix Design: 30090000 Admixture: Nis Sample By: Fernando Montalvo On 03/05/2019 At Lab On or Before: 03/06/2019 Specified Strength / Sampling Times Specified Strength: 3000 psi @ 28 days Mix Design Strength: 3000 psi @ 28 days Water Added at Site: N/A Time Batched: 5:03 AM Time Sampled: 5:23 AM Weather Condition: Partly Cloudy Field Test Results Placement Information Truck Load: 10.00 cu yds. Cumulative Quantity: 160.00 cu yds. Total Placement for the Day: 280.00 cu yds. Air Content: N/A Slump: 8.50 inches Ambient Temp: 61 °F I Concrete Temp: 72 °F Unit Weight: N/A Results of Laboratory Testing Test Results Date Tested Age Days Type Of Fracture Actual Dimen. 1 in) Actual Dimen. 2 in) Avg. Dimen. in) Test XSect. Area ( in') Max Compressive Load ( Ibs) Test Compressive Strength( psi) Average psi) 1 03/12/2019 7 5 4.00 4.01 4.01 12.63 27,560 2,180 2 04/02/2019 28 3 04/02/2019 28 4 04/02/2019 28 5' H' 04/02/2019 28 Remarks Cylinders are tested at seven (7) days to get an early indication of the potential strength of the concrete, but the seven (7) day results are not to be used for concrete acceptance. When the compressive strength of the concrete has reached 70% of the specified strength, it is a reasonable practice to use this as an indication that 100% of the specified strength will be attained by twenty-eight (28) days. Note H'- Hold Cylinder -'D'- Defective Cylinder, Un-testable -'E'- Excluded From Average Note Test Results represent the Structural Element specified If an air test was not completed, that deviates from C31 procedure L II L 7i l Sampled per ASTM C-172 - Yes Air Content Performed per ASTM C-173 or C-231 - No Unit Weight Performed per ASTM C-138 - N/A Slump Performed per ASTM C-143 - Yes Concrete Temperature Performed per ASTM C-1064 - Yes f Molded per C-31 - Yes Initially Cured per ASTM C-31 - Unknown t--- Capped in Lab to ASTM C-1231 d , tl Cured & Tested in Lab per ASTM C-31 & C-39 - Yes This Form Conforms With ASTM C-39 To establish a mutual protection to Universal's clients, the Public and ourselves, all reports are submitted as confidential property of our clients and authorization for publication of statements, conclusions or extracts from or regarding Universal's reports is reserved pending our written approval. This report shall not be reproduced, except in full, without the written approval of Universal Engineering Sciences. 1 of 1 Revised May 2018 Project No: 0110.1800758.0000UNIVERSALReportNo.: 9441234-5 CT 030519 Wo rko rda rN o.: 9441234 ENGINEERING SCIENCES Lab No.: 19N021-C Consultants In: Geotechnical Engineering • Environmental Sciences Date 1st Issue: March 13, 2019 Geophysical Services • Materials Testing • Threshold Inspection19BuildingCodeAdministration, Compliance Inspection & Plan Review 3532 Maggie Blvd, Orlando, FL 32811 - P: 407.423.0504 - F: 407.423.3106 Compressive Strength of 4" x 8" Cylinder Test Specimens ASTM C-39) Client The Spanos Corporation 2701 N. Rocky Point Drive, Suite 100, Tampa, FL 33607 Project Lake Monroe Apartments, Materials Testing US 92 & West 1 st Street, Sanford, Seminole County, FL 32771 Structural Element: Slab on Grade Sample Location: Building Slab D (Permit Number 17-1583) - Sampled at 15Ft S 10 Ft W on the SW Coner Of Slab Set# 5 of 6 Sample From: Concrete Truck General Information General Contractor: E.W Young Construction Subcontractor: Supplier: Maschmeyer Concrete Truck No.: 298 Ticket No.: 1850121 Mix Design: 30090000 Sample By: Fernando Montalvo On 03/05/2019 At Lab On or Before: 03/06/2019 Specified Strength / Sampling Times Specified Strength: 3000 psi @ 28 days Mix Design Strength: 3000 psi @ 28 days Water Added at Site: N/A Time Batched: 5:31 AM Time Sampled: 5:57 AM Admixture: Nis Weather Condition: Partly Cloudy Field Test Results Placement Information Truck Load: 10.00 cu yds. Cumulative Quantity: 210.00 cu yds. Total Placement for the Day: 280.00 cu yds. Air Content: N/A Slump: 7.25 inches Ambient Temp: 60 °F I Concrete Temp: 73 °F Unit Weight: N/A Results of Laboratory Testing Test Results Date Tested Age Days Type Of Fracture Actual Dimen.1 in) Actual Dimen.2 in) Avg. Dimen. in) Test X-Sect. Area (in') Max Compressive Load (Ibs) Test Compressive Strength(psi) Average psi) 1 03/12/2019 7 5 4.00 4.01 4.01 12.63 22,230 1,760 2 04/02/2019 28 3 04/02/2019 28 4 04/02/2019 28 5*H* 04/02/2019 28 Remarks Cylinders are tested at seven (7) days to get an early indication ofthe potential strength of the concrete, but the seven (7) day results are not to be used for concrete acceptance. When the compressive strength of the concrete has reached 70% of the specified strength, it is a reasonable practice to use this as an indication that 100% of the specified strength will be attained by twenty-eight (28) days. Note H'- Hold Cylinder -*D*- Defective Cylinder, Un-testable -*E*- Excluded From Average Note Test Results represent the Structural Element specified If an air test was not completed, that deviates from C31 procedure Sampled per ASTM C-172 -Yes Air Content Performed per ASTM C-173 or C-231 - Not_i I-111 I Unit Weight Performed per ASTM C-138 - N/A Slump Performed per ASTM C-143 - Yes Concrete Temperature Performed per ASTM C-1064 - Yes 77, I Molded per C-31 - Yes Initially Cured per ASTM C-31 - Unknown l Capped in Lab to ASTM C-1231 Cured & Tested in Lab per ASTM C-31 & C-39 - Yes This Form Conforms With ASTM C-39 To establish a mutual protection to Universal's clients, the Public and ourselves, all reports are submitted as confidential property of our clients and authorization for publication of statements, conclusions or extracts from or regarding Universal's reports is reserved pending our written approval. This report shall not be reproduced, except in full, without the written approval of Universal Engineering Sciences. 1 of 1 Revised May 2018 UNIVERSAL ENGINEERING SCIENCES Consultants In: Geotechnical Engineering • Environmental Sciences Geophysical Services • Materials Testing • Threshold Inspection Building Code Administration, Compliance Inspection & Plan Review 3532 Maggie Blvd, Orlando, FL 32811 - P: 407.423.0504 - F: 407.423.3106 Compressive Strength of 4" x 8" Cylinder Test Specimens ASTM C-39) Project No: 0110.1800758.0000 ReportNo.: 9441234-6 CT 030519 Wo rkordarN o.: 9441234 Lab No.: 19N022-C Date 1st Issue: March 13, 2019 Client The Spanos Corporation 2701 N. Rocky Point Drive, Suite 100, Tampa, FL 33607 Project Lake Monroe Apartments, Materials Testing US 92 & West 1st Street, Sanford, Seminole County, FL 32771 Structural Element: Slab on Grade Sample Location: Building Slab D (Permit Number 17-1583) - Sampled at 10Ft W 15 Ft N on the NW Coner Of Slab Set# 6 of 6 Sample From: Concrete Truck Sample By: Fernando Montalvo On 03/05/2019 At Lab On or Before: 03/06/2019 General Information Specified Strength / Sampling Times Placement Information General Contractor: E.W Young Construction Specified Strength: 3000 psi @ 28 days Truck Load: 10.00 cu yds. Subcontractor: Mix Design Strength: 3000 psi @ 28 days Cumulative Quantity: 260.00 cu yds. Supplier: Maschmeyer Concrete Water Added at Site: N/A Total Placement for the Day: 280.00 cu yds. Truck No.: 622 Time Batched: 7:44 AM Ticket No.: 1850132 Time Sampled: 8:05 AM Mix Design: 30090000 Admixture: Nis Weather Condition: Partly Cloudy Field Test Results Air Content: N/A Slump: 7.00 inches Ambient Temp: 59 °F I Concrete Temp: 72 *F Unit Weight: N/A Results of Laboratory Testing Test Results Date Tested Age Days Type Of Fracture Actual Dimen.1 in) Actual Dimen.2 in) Avg. Dimen. in) Test X-Sect. Area (in') Max Compressive Load (Ibs) Test Compressive Strength(psi) Average psi) 1 03/12/2019 7 5 4.00 4.02 4.01 12.63 26,970 2,140 2 04/02/2019 28 3 04/02/2019 28 4 04/02/2019 28 5*H* 04/02/2019 28 Remarks Cylinders are tested at seven (7) days to get an early indication of the potential strength of the concrete, but the seven (7) day results are not to be used for concrete acceptance. When the compressive strength of the concrete has reached 70% of the specified strength, it is a reasonable practice to use this as an indication that 100% of the specified strength will be attained by twenty-eight (28) days. Note H*- Hold Cylinder -*D*- Defective Cylinder, Un-testable -*E*- Excluded From Average Note Test Results represent the Structural Element specified If an air test was not completed, that deviates from C31 procedure FIR 7] Sampled per ASTM C-172 - Yes Air Content Performed per ASTM C-173 or C-231 - No Unit Weight Performed per ASTM C-138 - N/A Slump Performed per ASTM C-143 - Yes Concrete Temperature Performed per ASTM C-1064 - Yes Molded per C-31 - Yes Initially Cured per ASTM C-31 - Unknown Capped in Lab to ASTM C-1231 Cured & Tested in Lab per ASTM C-31 & C-39 - Yes This Form Conforms With ASTM C-39 To establish a mutual protection to Universal's clients, the Public and ourselves, all reports are submitted as confidential property of our clients and authorization forpublication of statements, conclusions or extracts from or regarding Universal's reports is reserved pending our written approval. This report shall not be reproduced, exceptin full, without the written approval of UniversalEngineeringSciences. 1 of 1 Revised May 2018 UNIVERSAL ENGINEERING SCIENCES Consultants In: Geotechnical Engineering • Environmental Sciences Geophysical Services • Materials Testing • Threshold Inspection Building Code Administration, Compliance Inspection & Plan Review 3532 Maggie Blvd, Orlando, FL 32811 - P: 407.423.0504 - F: 407.423.3106 UES Project No: 0110.1800758.0000 Workorder No: 9441503-1 Report Date: 03/13/2019 In -Place Density Test Report Client: The Spanos Corporation UES Technician: Fernando Montalvo 2701 N. Rocky Point Drive, Suite 100 Date Tested: 03/12/2019 Tampa, FL 33607 Project: Lake Monroe Apartments, Materials Testing US 92 & West 1 st Street, Sanford, Seminole County, FL 32771 Type of Test: Area Tested: Sanitary Pipe (Permit Number 18- Field: ASTM D-2937 Drive Cylinder Method 2508) Material: Backfill Laboratory: ASTM D1557 Modified Proctor Reference Datum: 0 = Springline of Pipe The fccfc KcIn%A/ MOM fha QRO/ minimum r-mmnaCtlr)n rpnl llrpmpnt_ Maximum Optimum Field Dry Field Soil Pass Test I Density Moisture Density Moisture Compaction or No. Location of Test Range pcf) pcf) Fail 1 E to G 8" PVC 3+4 ft 111.5 11.3 110.6 8.3 99 Pass 2 E to G 8" PVC 4+5 ft 111.5 11.3 111.9 7.1 100 1 Pass To establish a mutual protection to Universal's clients, the Public and ourselves, all reports are submitted as confidential property of our clients and authorization for publication of statements, conclusions or extracts from or regarding Universal's reports is reserved pending our written approval. Page 1 UNIVERSAL ENGINEERING SCIENCES Consultants In: Geotechnical Engineering • Environmental Sciences Geophysical Services • Materials Testing • Threshold Inspection Building Code Administration, Compliance Inspection & Plan Review 3532 Maggie Blvd, Orlando, FL 32811 - P: 407.423.0504 - F: 407.423.3106 UES Project No: 0110.1800758.0000 Workorder No: 9441504-1 Report Date: 03/13/2019 In -Place Density Test Report Client: The Spanos Corporation UES Technician: Fernando Montalvo 2701 N. Rocky Point Drive, Suite 100 Date Tested: 03/13/2019 Tampa, FL 33607 Project: Lake Monroe Apartments, Materials Testing US 92 & West 1 st Street, Sanford, Seminole County, FL 32771 Type of Test: Area Tested: Sanitary Pipe (Permit Number 18- Field: ASTM D-2937 Drive Cylinder Method 2508) Material: Backfill Laboratory: ASTM D1557 Modified Proctor Reference Datum: 0 = Springline of Pipe Thn taete Kninim mast the- QRO/ minimsIm mmnnnfinn rpniiirpmpnt_ Maximum Optimum Field Dry Field Soil Pass Test I Density Moisture Density Moisture Compaction or No. Location of Test Range pcf) N pcf) N N Fail 1 V 10 to V 2 8" PVC 0-1 ft 111.5 11.3 111.7 8.8 100 Pass 2 V 10 to V 2 8" PVC 0+1 ft 111.5 11.3 111.1 8.1 100 Pass 3 V 10 to V 2 8" PVC 1+2 ft 111.5 11.3 110.2 7.7 99 Pass 4 V 10 to V 2 8" PVC 2+3 ft 111.5 11.3 110.5 7.2 99 Pass To establish a mutual protection to Universal's clients, the Public and ourselves, all reports are submitted as confidential property of our clients and authorization for publication of statements, conclusions or extracts from or regarding Universal's reports is reserved pending our written approval. Page 1 UNIVERSAL ENGINEERING SCIENCES Consultants In: Geotechnical Engineering • Environmental Sciences Geophysical Services • Materials Testing • Threshold Inspection Building Code Administration, Compliance Inspection & Plan Review 3532 Maggie Blvd, Orlando, FL 32811 - P: 407.423.0504 - F: 407.423.3106 UES Project No: 0110.1800758.0000 Workorder No: 9441504-2 Report Date: 03/13/2019 In -Place Density Test Report Client: The Spanos Corporation UES Technician: Fernando Montalvo 2701 N. Rocky Point Drive, Suite 100 Date Tested: 03/13/2019 Tampa, FL 33607 Project: Lake Monroe Apartments, Materials Testing US 92 & West 1st Street, Sanford, Seminole County, FL 32771 Type of Test: Area Tested: Sanitary Structure (Permit Number 18 Field: ASTM D-2937 Drive Cylinder Method 2508) Material: Backfill Laboratory: ASTM D1557 Modified Proctor Reference Datum: 0 = Bottom of Sanitary Structure Tha tactc halnw mast }ha 9R% minimllm Cmmnnrtion rP.nIllrpmpnt. Maximum Optimum Field Dry Field Soil Pass Test Density Moisture Density Moisture Compaction or No. Location of Test Range pcf) N pcf) N Fail 5 Structure V2 0+1 ft 111.5 11.3 111.4 8.4 100 Pass 6 Structure V2 1+2 ft 111.5 11.3 110.5 7.6 99 Pass 7 Structure V2 2+3 ft 1 111.5 1 11.3 1 110.0 1 7.3 1 99 1 Pass To establish a mutual protection to Universal's clients, the Public and ourselves, all reports are submitted as confidential property of our clients and authorization for publication of statements, conclusions or extracts from or regarding Universal's reports is reserved pending our written approval. Page 1 UNIVERSAL ENGINEERING SCIENCES Consultants In: Geotechnical Engineering • Environmental Sciences Geophysical Services • Materials Testing • Threshold Inspection Building Code Administration, Compliance Inspection & Plan Review 3532 Maggie Blvd, Orlando, FL 32811 - P: 407.423.0504 - F: 407.423.3106 UES Project No.: 0110.1800758.0000 Date Typed: February 28, 2019 Construction Materials Testing Services FIELD AND LABORATORY REPORT COVER PAGE Client: The Spanos Corporation 2701 N. Rocky Point Drive, Suite 100 Tampa, FL 33607 Project: Lake Monroe Apartments, Materials Testing US 92 & West 1st Street, Sanford, Seminole County, FL 32771 As requested, Universal Engineering Sciences, Inc. (LIES) representative(s) performed construction materials testing and/or field inspection services on the above project. Testing results and/or inspection observations are reported on the attached sheets. The contents of this package are summarized below: Scope of Work Work Order No. Date Type of Report 9432778-1 01/30/2019 4" x 8" Cylinder Test Specimens Report 9432778-2 01/30/2019 4" x 8" Cylinder Test Specimens Report 9432778-3 01/30/2019 4" x 8" Cylinder Test Specimens Report 9432778-4 01/30/2019 4" x 8" Cylinder Test Specimens Report 9432778-5 1 01/30/2019 4" x 8" Cylinder Test Specimens Report We hope this information is sufficient for your immediate needs. If you have any questions, please do not hesitate to contact the undersigned or Rosie Housein (extension 23078). Attachments (5) rh Sincerely, Universal Engineering Sciences, Inc. Certificate of Authorization No. 00000549 yr;"M Fred Schmalzer 2019.03.05A 07:37:55-05'00' Fred J. Schmalzer, P.E. Vice President - Construction Services STATE OF FLORIDA Professional Engineer No. 38818 This item has been electronically signed and sealed by Fred J. Schmalzer, P.E. using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. For the mutual protection of Universal's clients, the general public, and ourselves, our reports are submitted as the confidential property of our clients. Accordingly, authorization for reliance upon, or publication of, all or portions of this report is reserved pending our written approval. Revised May 2015 UNIVERSAL ENGINEERING SCIENCES Consultants In: Geotechnical Engineering • Environmental Sciences Geophysical Services • Materials Testing • Threshold Inspection Building Code Administration, Compliance Inspection & Plan Review 3532 Maggie Blvd, Orlando, FL 32811 - P: 407.423.0504 - F: 407.423.3106 Compressive Strength of 4" x 8" Cylinder Test Specimens ASTM C-39) Project No: 0110.1800758.0000 ReportNo.: 9432778-1 CT 013019 Wo rkord arNo.: 9432778 Lab No.: 19M030-C Date 1st Issue: February 07, 2019 Client The Spanos Corporation 2701 N. Rocky Point Drive, Suite 100, Tampa, FL 33607 Project Lake Monroe Apartments, Materials Testing US 92 & West 1 st Street, Sanford, Seminole County, FL 32771 Structural Element: Slab on Grade Sample Location: Building C ( Permit Number 17-1582) - Sampled at Southwest Corner of Building C Pad Set# 1 of 5 Sample From: Concrete Truck Sample By: Carmelo Cuadrado Pagan On At Lab On or Before: 01/31/2019 01 /30/2019 General Information Specified Strength / Sampling Times Placement Information General Contractor: E W Young Construction INC Specified Strength: 3000 psi @ 28 days Truck Load: 10.00 cu yds. Subcontractor: Mix Design Strength: 3000 psi @ 28 days Cumulative Quantity: 20.00 cu yds. Supplier: Maschmeyer Concrete Water Added at Site: N/A Total Placement for the Day: 230.00 cu yds. Truck No.: 602 Time Batched: 3:30 AM Ticket No.: 1171588 Time Sampled: 4:18 AM Mix Design: 30090000 Admixture: N/S Weather Condition: Partly Cloudy Field Test Results Air Content: N/A Slump: 7.00 inches Ambient Temp: 54 °F I Concrete Temp: 61 °F Unit Weight: N/A Results of Laboratory Testing Test Results Date Tested Age Days Type Of Fracture Actual Dimen.1 in) Actual Dimen.2 in) Avg. Dimen. in) Test X-Sect. Area (in') Max Compressive Load (Ibs) Test Compressive Strength(psi) Average psi) 1 02/06/2019 7 5 4.02 4.01 4.02 12.69 25,895 2,040 2 02/27/2019 28 5 4.01 4.02 4.02 12.69 57,775 4,552 3 02/27/2019 28 5 4.01 4.02 4.02 12.69 59,365 4,677 4 02/27/2019 28 51 1 4.01 4.02 4.02 1 12.69 57,490 4,530 4,590 5*1`1* 02/27/2019 28 I - I - Remarks Cylinders are tested at seven (7) days to get an early indication of the potential strength of the concrete, but the seven (7) day results are not to be used for concreteacceptance. When the compressive strength of the concrete has reached 70% of the specified strength, it is a reasonable practice to use this as an indication that 100% of the specified strength will be attained by twenty-eight (28) days. Note H*- Hold Cylinder -*D*- Defective Cylinder, Un-testable -*E*- Excluded From Average Note Test Results represent the Structural Element specified If an air testwas not completed, that deviates from C31 procedure IN 0 ' WL,l H n E F111 Sampled per ASTM C-172 - Yes Air Content Performed per ASTM C-173 or C-231 - No Unit Weight Performed per ASTM C-138 - N/A Slump Performed per ASTM C-143 - Yes Concrete Temperature Performed per ASTM C-1064 - Yes Molded per C-31 - Yes Initially Cured per ASTM C-31 - Unknown Capped in Lab to ASTM C-1231 Cured & Tested in Lab per ASTM C-31 & C-39 - Yes This Form Conforms With ASTM C-39 To establish a mutual protection to Universal's clients, the Public and ourselves, all reports are submitted as confidential property of our clients and authorization for publication of statements, conclusions or extracts from or regarding Universal's reports is reserved pending our written approval. This report shall not be reproduced, except in full, without the written approval of Universal Engineering Sciences. 1 of 1 Revised May 2018 000UNIVERSALProjectNo: 94327 8 - 2 CT 0130ReportNo.: 9432778-2 CT 013019 Wo rko rdarN o.: 9432778 ENGINEERING SCIENCES Lab No.: 19M031 -C Consultants In: Geotechnical Engineering - Environmental Sciences Date 1st Issue: February 07, 2019 Geophysical Services - Materials Testing - Threshold Inspection03BuildingCodeAdministration, Compliance Inspection & Plan Review 3532 Maggie Blvd, Orlando, FL 32811 - P: 407.423.0504 - F: 407.423.3106 Compressive Strength of 4" x 8" Cylinder Test Specimens ASTM C-39) Client The Spanos Corporation 2701 N. Rocky Point Drive, Suite 100, Tampa, FL 33607 Project Lake Monroe Apartments, Materials Testing US 92 & West 1st Street, Sanford, Seminole County, FL 32771 Structural Element: Slab on Grade Sample Location: Building C ( Permit Number 17-1582) - Sampled at 33ft South from North End and 62ft East from West End of Buildings Edge Set# 2 of 5 Sample From: Concrete Truck General Information General Contractor: E W Young Construction INC Subcontractor: Supplier: Maschmeyer Concrete Truck No.: 287 Ticket No.: 1171590 Mix Design: 30090000 Admixture: Nis Sample By: Carmelo Cuadrado Pagan On 01 /30/2019 Specified Strength / Sampling Times Specified Strength: 3000 psi @ 28 days Mix Design Strength: 3000 psi @ 28 days Water Added at Site: N/A Time Batched: 4:01 AM Time Sampled: 4:50 AM Weather Condition: Partly Cloudy Field Test Results At Lab On or Before: 01/31/2019 Placement Information Truck Load: 10.00 cu yds. Cumulative Quantity: 60.00 cu yds. Total Placement for the Day: 230.00 cu yds. Air Content: N/A Slump: 6.50 inches Ambient Temp: 52 of I Concrete Temp: 63 -F Unit Weight: N/A Results of Laboratory Testing Test Results Date Tested Age Days Type Of Fracture Actual Dimen.1 in) Actual Dimen.2 in) Avg. Dimen. in) Test X-Sect. Area (in2) Max Compressive Load (Ibs) Test Compressive Strength(psi) Average psi) 1 02/06/2019 7 5 4.00 4.02 4.01 12.63 29,680 2,350 2 02/27/2019 28 5 4.00 4.02 4.01 12.63 60,325 4,777 3 02/27/2019 28 5 4.00 4.02 4.01 12.63 59,765 41732 4 02/27/2019 28 5 4.02 4.00 4.01 12.63 60,745 4,810 4,770 5*H* 02/27/2019 28 Remarks Cylinders are tested at seven (7) days to get an early indication of the potential strength of the concrete, but the seven (7) day results are not to be used for concreteacceptance. When the compressive strength of the concrete has reached 70% of the specified strength, it is a reasonable practice to use this as an indication that 100% of the specified strength will be attained by twenty-eight (28) days. Note H*- Hold Cylinder -*D*- Defective Cylinder, Un-testable -*E*- Excluded From Average Note Test Results represent the Structural Element specified If an air test was not completed, that deviates from C31 procedure Sampled per ASTM C-172 - Yes Air Content Performed per ASTM C-173 or C-231 - No Unit Weight Performed per ASTM C-138 - N/A Slump Performed per ASTM C-143 - Yes Concrete Temperature Performed per ASTM C-1064 - Yes Molded per C-31 - Yes Initially Cured per ASTM C-31 - Unknown Capped in Lab to ASTM C-1231 Cured & Tested in Lab per ASTM C-31 & C-39 - Yes This Form Conforms With ASTM C-39 To establish a mutual protection to Universal's clients, the Public and ourselves, all reports are submitted as confidential property ofour clients and authorization forpublication of statements, conclusions or extracts from or regarding Universal's reports is reserved pending our written approval. This report shall not be reproduced, except in full, without the written approval of Universal Engineering Sciences. 1 of 1 Revised May 2018 Project No: 0110.1UNIVERSALReportNo.: 9432778-0 CT 00133019 9432778 ENGINEERING SCIENCES WorkoLab rNo.: 119M032-C Consultants In: Geotechnical Engineering • Environmental Sciences Date 1st Issue: February 07, 2019 Geophysical Services • Materials Testing • Threshold Inspection EDBuildingCodeAdministration, Compliance Inspection & Plan Review 3532 Maggie Blvd, Orlando, FL 32811 - P: 407.423.0504 - F: 407.423.3106 Compressive Strength of 4" x 8" Cylinder Test Specimens ASTM C-39) Client The Spanos Corporation 2701 N. Rocky Point Drive, Suite 100, Tampa, FL 33607 Project Lake Monroe Apartments, Materials Testing US 92 & West 1 st Street, Sanford, Seminole County, FL 32771 Structural Element: Slab on Grade Sample Location: Building C ( Permit Number 17-1582) - Sampled at 28ft North from South End and 85ft West from East End Buildings Edge Set# 3 of 5 Sample From: Concrete Truck General Information General Contractor: E W Young Construction INC Subcontractor: Supplier: Maschmeyer Concrete Truck No.: 653 Ticket No.: 1202191 Mix Design: 30090000 Sample By: Carmelo Cuadrado Pagan On 01 / 30/2019 Specified Strength / Sampling Times Specified Strength: 3000 psi @ 28 days Mix Design Strength: 3000 psi @ 28 days Water Added at Site: N/A Time Batched: 4:40 AM Time Sampled: 5:33 AM Admixture: NIS Weather Condition: Partly Cloudy Field Test Results At Lab On or Before: 01/31/2019 Placement Information Truck Load: 10.00 cu yds. Cumulative Quantity: 100.00 cu yds. Total Placement for the Day: 230.00 cu yds. Air Content: N/A Slump: 4.50 inches Ambient Temp: 52 °F I Concrete Temp: 60 °F Unit Weight: N/A Results of Laboratory Testing Test Results Date Tested Age Days Type Of Fracture Actual Dimen. 1 in) Actual Dimen. 2 in) Avg. Dimen. in) Test X- Sect. Area ( in2) Max Compressive Load ( Ibs) Test Compressive Strength( psi) Average psi) 1 02/06/2019 7 5 4.00 4.01 4.01 12.63 35,150 2,780 2 02/27/2019 28 5 4.00 4.01 4.01 12.63 67,155 5,317 3 02/27/2019 28 5 4.00 4.01 4.01 12.63 67,710 5,361 4 02/27/2019 28 5 4.00 4.00 4.00 12.57 70,340 I5,597 5,430 5* H* 02/27/2019 28 Remarks Cylinders are tested at seven (7) days to get an early indication of the potential strength of the concrete, but the seven (7) day results are not to be used for concrete acceptance. When the compressive strength of the concrete has reached 70% of the specified strength, it is a reasonable practice to use this as an indication that 100% of the specified strength will be attained by twenty-eight (28) days. Note H*- Hold Cylinder *D*- Defective Cylinder, Un-testable -*E*- Excluded From Average Note Test Results represent the Structural Element specified If an air test was not completed, that deviates from C31 procedure q rk In F1 Sampled per ASTM C-172 - Yes Air Content Performed per ASTM C-173 or C-231 - No Unit Weight Performed per ASTM C-138 - N/A Slump Performed per ASTM C-143 - Yes Concrete Temperature Performed per ASTM C-1064 - Yes Molded per C-31 - Yes Initially Cured per ASTM C-31 - Unknown Capped in Lab to ASTM C-1231 Cured & Tested in Lab per ASTM C-31 & C-39 - Yes This Form Conforms With ASTM C-39 To establish a mutual protection to Universal's clients, the Public and ourselves, all reports are submitted as confidential property of ourclients and authorization for publicationof statements, conclusionsorextractsfromorregardingUniversal's reports is reserved pending our written approval. This report shall not be reproduced, except in full, without the written approval of Universal Engineering Sciences. 1 of 1 Revised May 2018 Project No: 0110. UNIVERSAL ReportNo.: 94322778-4 CT 00133019 9432778 ENGINEERING SCIENCES WorkoLab rNo.:119M033C Consultants In: Geotechnical Engineering • Environmental Sciences Date 1st Issue: February 07, 2019 Geophysical Services • Materials Testing • Threshold Inspection Building Code Administration, Compliance Inspection & Plan Review 3532 Maggie Blvd, Orlando, FL 32811 - P: 407.423.0504 - F: 407.423.3106 Compressive Strength of 4" x 8" Cylinder Test Specimens ASTM C-39) Client The Spanos Corporation 2701 N. Rocky Point Drive, Suite 100, Tampa, FL 33607 Project Lake Monroe Apartments, Materials Testing US 92 & West 1st Street, Sanford, Seminole County, FL 32771 Structural Element: Slab on Grade Sample Location: Building C ( Permit Number 17-1582) - Sampled at 46ft South from North End and 73ft West from East End of Buildings Edge Set# 4 of 5 Sample From: Concrete Truck General Information General Contractor: E W Young Construction INC Subcontractor: Supplier: Maschmeyer Concrete Truck No.: 622 Ticket No.: 1171596 Mix Design: 30090000 Admixture: N/S Sample By: Carmelo Cuadrado Pagan On 01 / 30/2019 Specified Strength / Sampling Times Specified Strength: 3000 psi @ 28 days Mix Design Strength: 3000 psi @ 28 days Water Added at Site: N/A Time Batched: 5:27 AM Time Sampled: 6:13 AM Weather Condition: Partly Cloudy Field Test Results At Lab On or Before: 01/31/2019 Placement Information Truck Load: 10.00 cu yds. Cumulative Quantity: 150.00 cu yds. Total Placement for the Day: 230.00 cu yds. Air Content: N/A Slump: 7.50 inches I Ambient Temp: 52 °F I Concrete Temp: 62 °F Unit Weight: N/A Results of Laboratory Testing Test Results Date Tested Age Days Type Of Fracture Actual Dimen. 1 in) Actual Dimen. 2 in) Avg. Dimen. in) Test X- Sect. Area ( in2) Max Compressive Load ( Ibs) Test Compressive Strength( psi) Average psi) 1 02/06/2019 7 5 4.02 4.00 4.01 12.63 26,900 2,130 2 02/27/2019 28 5 4.00 4.02 4.01 12.63 57,185 4,528 3 02/27/2019 28 5 4.00 4.02 4.01 12.63 56,315 4,459 4 02/27/2019 28 5 4.00 4.02 4.01 12.63 1 59,135 4,682 4,560 5* H* 02/27/2019 28 I - I - Remarks Cylinders are tested at seven (7) days to get an early indication of the potential strength of the concrete, but the seven (7) day results are not to be used for concrete acceptance. When the compressive strength of theconcrete has reached 70% of the specified strength, it is a reasonable practice to use this as an indication that 100% of the specified strength will be attained by twenty-eight (28) days. Note H*- Hold Cylinder -*D*- Defective Cylinder, Un-testable -*E*- Excluded From Average Note Test Results represent the Structural Element specified If an air test was not completed, that deviates from C31 procedure Sampled per ASTM C-172 - Yes Air Content Performed per ASTM C-173 or C-231 - No per UnitWeight Performed per ASTM C-138 - N/A Slump Performed per ASTM C-143 - Yes Concrete Temperature Performed per ASTM C-1064 - Yes I n5Initially c"} L Molded per C-31 - Yes Cured per ASTM C-31 - Unknown Capped in Lab to ASTM C-1231 Cured & Tested in Lab per ASTM C-31 & C-39 - Yes This Form Conforms With ASTM C-39 To establish a mutual protection to Universal's clients, the Public and ourselves, all reports are submitted as confidential property of our clients andauthorization for publication of statements, conclusions or extracts from or regarding Universal's reports is reserved pending our written approval. This report shall not be reproduced, except in full, without the written approval of Universal Engineering Sciences. 1 of 1 Revised May 2018 UNIVERSAL ENGINEERING SCIENCES Consultants In: Geotechnical Engineering • Environmental Sciences Geophysical Services • Materials Testing • Threshold Inspection Building Code Administration, Compliance Inspection & Plan Review 3532 Maggie Blvd, Orlando, FL 32811 - P: 407.423.0504 - F: 407.423.3106 Compressive Strength of 4" x 8" Cylinder Test Specimens ASTM C-39) Client The Spanos Corporation 2701 N. Rocky Point Drive, Suite 100, Tampa, FL 33607 Project Lake Monroe Apartments, Materials Testing US 92 & West 1st Street, Sanford, Seminole County, FL 32771 Project No: 0110.1800758.0000 ReportNo.: 9432778-5 CT 013019 Worko rda rNo.: 9432778 Lab No.: 19MO34-C Date list Issue: February 07, 2019 Structural Element: Slab on Grade Sample Location: Building C ( Permit Number 17-1582) - Sampled at Northeast Corner of Building C Pad Set# 5 of 5 Sample From: Concrete Truck Sample By: Carmelo Cuadrado Pagan On At Lab On or Before: 01/31/2019 01 /30/2019 General Information General Contractor: E W Young Construction INC Subcontractor: Supplier: Maschmeyer Concrete Truck No.: 653 Ticket No.: 1202199 Mix Design: 30090000 Admixture: N/S Specified Strength / Sampling Times Specified Strength: 3000 psi @ 28 days Mix Design Strength: 3000 psi @ 28 days Water Added at Site: N/A Time Batched: 6:28 AM Time Sampled: 7:17 AM Weather Condition: Partly Cloudy Field Test Results Placement Information Truck Load: 10.00 cu yds. Cumulative Quantity: 210.00 cu yds. Total Placement for the Day: 230.00 cu yds. Air Content: N/A Slump: 6.00 inches I Ambient Temp: 52 °F I Concrete Temp: 60 °F Unit Weight: N/A Results of Laboratory Testing Test Results Date Tested Age Days Type Of Fracture Actual Dimen.1 in) Actual Dimen.2 in) Avg. Dimen. in) Test X-Sect. Area (in2) Max Compressive Load (Ibs) Test Compressive Strength(psi) Average psi) 1 02/06/2019 7 5 4.00 4.02 4.01 12.63 30,125 2,390 2 02/27/2019 28 5 4.00 4.02 4.01 12.63 67,375 5,335 3 02/27/2019 28 5 4.00 4.02 4.01 12.63 67,855 5,373 4 02/27/2019 28 5 1 4.00 1 4.02 1 4.01 1 12.63 1 71,210 5,638 5,450 5*H* 02/27/2019 28 I - I - I - I - I - Remarks Cylinders are tested at seven (7) days to get an early indication of the potential strength of the concrete, but the seven (7) day results are not to be used for concrete acceptance. When the compressive strength of the concrete has reached 70% of the specified strength, it is a reasonable practice to use this as an indication that 100% of the specified strength will be attained by twenty-eight (28) days. Note H*- Hold Cylinder *D*- Defective Cylinder, Un-testable *E*- Excluded From Average Note Test Results represent the Structural Element specified If an air test was not completed, that deviates from C31 procedure I Sampled per ASTM C-172 - Yes t-1 L—I I Air Content Performed per ASTM C-173 or C-231 - No Unit Weight Performed per ASTM C-138 - N/A Slump Performed per ASTM C 143 Yes Concrete Temperature Performed per ASTM C-1064 - Yes l f? Molded per C-31 - YesIInitiallyCuredperASTM C-31 - Unknown Capped in Lab to ASTM C-1231 Cured & Tested in Lab per ASTM C-31 & C-39 - Yes This Form Conforms With ASTM C-39 To establish a mutual protection to Universal's clients, the Public and ourselves, all reports are submitted as confidential property of our clients and authorization for publication of statements, conclusions or extracts from or regarding Universal's reports is reserved pending our written approval. This report shall not be reproduced, except in full, without the written approval of Universal Engineering Sciences. 1 of 1 Revised May 2018 UNIVERSAL ENGINEERING SCIENCES Consultants In: Geotechnical Engineering • Environmental Sciences Geophysical Services • Materials Testing • Threshold Inspection Building Code Administration, Compliance Inspection & Plan Review 3532 Maggie Blvd, Orlando, FL 32811 - P: 407.423.0504 - F: 407.423.3106 UES Project No.: 0110.1800758.0000 Date Typed: February 21, 2019 Construction Materials Testing Services FIELD AND LABORATORY REPORT COVER PAGE Client: The Spanos Corporation 2701 N. Rocky Point Drive, Suite 100 Tampa, FL 33607 Project: Lake Monroe Apartments, Materials Testing US 92 & West 1st Street, Sanford, Seminole County, FL 32771 As requested, Universal Engineering Sciences, Inc. (LIES) representative(s) performed construction materials testing and/or field inspection services on the above project. Testing results and/or inspection observations are reported on the attached sheets. The contents of this package are summarized below: Scope of Work Work Order No. Date Type of Report 9431929-1 01/23/2019 4" x 8" Cylinder Test Specimens Report 9432020-1 01/23/2019 4" x 8" Cylinder Test Specimens Report 9433920-1 02/19/2019 In -Place Density Test Report 9433920-2 1 02/19/2019 In -Place Density Test Report We hope this information is sufficient for your immediate needs. If you have any questions, please do not hesitate to contact the undersigned or Rosie Housein (extension 23078). Attachments (5) rh Sincerely, Universal Engineering Sciences, Inc. Certificate of Authorization No. 00000549 crinI'%>„ Fred SchmalzerC,f RISE .•, I a - 2019.03.05 07:39:48-05'00' Fred J. Schmalzer, P.E. Vice President Construction Services STATE OF FLORIDA Professional Engineer No. 38818 This item has been electronically signed and sealed by Fred J. Schmalzer, P.E. using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. For the mutual protection of Universal's clients, the general public, and ourselves, our reports are submitted as the confidential property of our clients. Accordingly, authorization for reliance upon, or publication of, all or portions of this report is reserved pending our written approval. Revised May 2015 UNIVERSAL ENGINEERING SCIENCES Consultants In: Geotechnical Engineering • Environmental Sciences Geophysical Services • Materials Testing • Threshold Inspection Building Code Administration, Compliance Inspection & Plan Review 3532 Maggie Blvd, Orlando, FL 32811 - P: 407.423.0504 - F: 407.423.3106 Compressive Strength of 4" x 8" Cylinder Test Specimens ASTM C-39) Client The Spanos Corporation 2701 N. Rocky Point Drive, Suite 100, Tampa, FL 33607 Project Lake Monroe Apartments, Materials Testing US 92 & West 1st Street, Sanford, Seminole County, FL 32771 Structural Element: Slab on Grade Sample Location: Building E Elevator Pit (Permit #17-1584) - Sampled at Center of Pad Set# 1 of 1 Sample From: Concrete Truck General Information General Contractor: The Spanos Corp Subcontractor: Supplier: Maschmeyer Concrete Truck No.: 287 Ticket No.: 117146 Mix Design: 30090000 Admixture: N/S Sample By: DiJon Davis On 01/23/2019 Specified Strength I Sampling Times Specified Strength: 3000 psi @ 28 days Mix Design Strength: 3000 psi @ 28 days Water Added at Site: N/A Time Batched: 1:49 PM Time Sampled: 2:34 PM Weather Condition: Partly Cloudy Field Test Results Project No: 0110.1800758.0000 ReportNo.: 9431929-1 CT 012319 Worko rdarN o.: 9431929 Lab No.: 191-850-C Date 1st Issue: January 31, 2019 At Lab On or Before: 01/24/2019 Placement Information Truck Load: 10.00 cu yds. Cumulative Quantity: 10.00 cu yds. Total Placement for the Day: 10.00 cu yds. Air Content: N/A Slump: 5.00 inches Ambient Temp: 69 OF I Concrete Temp: 80 °F Unit Weight: NIA Results of Laboratory Testing Test Results Date Tested Age Days Type Of Fracture Actual Dimen.1 in) Actual Dimen.2 in) Avg. Dimen. in) Test X-Sect. Area (in2) Max Compressive Load (Ibs) Test Compressive Strength(psi) Average psi) 1 01/30/2019 7 5 4.00 4.02 4.01 12.63 23,705 1,880 2 02/20/2019 28 5 4.00 4.02 4.01 12.63 52,400 4,149 3 02/20/2019 28 5 4.00 4.02 4.01 12.63 49,205 3,896 1 - 4 02/20/2019 28 5 4.00 4.00 4.00 12.57 50,945 4, 4,030 H5** 02/20/2019 28 54 Remarks Cylinders are tested at seven (7) days to get an early indication of the potential strength of the concrete, but the seven (7) day results are not to be used for concrete acceptance. When the compressive strength of the concrete has reached 70% of the specified strength, it is a reasonable practice to use this as an indication that 100% of the specified strength will be attained by twenty-eight (28) days. Note H*- Hold Cylinder -*D*- Defective Cylinder, Un-testable -*E*- Excluded From Average Note Test Results represent the Structural Element specified If an air test was not completed, that deviates from C31 procedure 1 f 7T' Sampled per ASTM C-172 - Yes Air Content Performed per ASTM C-173 or C-231 - No Unit Weight Performed per ASTM C-138 - N/A Slump Performed per ASTM C-143 - Yes Concrete Temperature Performed per ASTM C-1064 - Yes Molded per C 31 -Yes Initially Cured per ASTM C-31 -Unknown Capped in Lab to ASTM C-1231 Cured & Tested in Lab per ASTM C-31 & C-39 - Yes This Form Conforms With ASTM C-39 To establish a mutual protection to Universal's clients, the Public and ourselves, all reports are submitted as confidential property of our clients and authorization for publication of statements, conclusions or extracts from or regarding Universal's reports is reserved pending our written approval. This report shall not be reproduced, except in full, without the written approval of Universal Engineering Sciences. 1 of 1 Revised May 2018 Project No: UNIVERSAL ReportNo.: 9432020-01 CT 012319 432020 ENGINEERING SCIENCES WorkoLab rNo.: 19L851 C Consultants In: Geotechnical Engineering • Environmental Sciences Date 1st Issue: February 21, 2019 Geophysical Services • Materials Testing • Threshold Inspection 03BuildingCodeAdministration, Compliance Inspection & Plan Review 3532 Maggie Blvd, Orlando, FL 32811 - P: 407.423.0504 - F: 407.423.3106 Compressive Strength of 4" x 8" Cylinder Test Specimens ASTM C-39) Client The Spanos Corporation 2701 N. Rocky Point Drive, Suite 100, Tampa, FL 33607 Project Lake Monroe Apartments, Materials Testing US 92 & West 1st Street, Sanford, Seminole County, FL 32771 Structural Element: Cell Fill Sample Location: Building B Tower Cell Fill (Permit #17-1581) - Sampled at Northeast Corner of Wall Set# 1 of 1 Sample From: Concrete Truck General Information General Contractor: The Spanos core Subcontractor: Supplier: Maschmeyer Concrete Truck No.: 646 Ticket No.: 117447 Mix Design: 30550000 Admixture: N/S Sample By: DiJon Davis On 01/23/2019 Specified Strength / Sampling Times Specified Strength: 3000 psi @ 28 days Mix Design Strength: 3000 psi @ 28 days Water Added at Site: N/A Time Batched: 1:38 PM Time Sampled: 2:38 PM Weather Condition: Partly Cloudy Field Test Results At Lab On or Before: 01/28/2019 Placement Information Truck Load: 4.00 cu yds. Cumulative Quantity: 4.00 cu yds. Total Placement for the Day: 4.00 cu yds. Air Content: N/A Slump: 6.50 inches Ambient Temp: 69 OF I Concrete Temp: 83 OF Unit Weight: NIA Results of Laboratory Testing Test Results Date Tested Age Days Type Of Fracture Actual Dimen. 1 in) Actual Dimen. 2 in) Avg. Dimen. in) Test X- Sect. Area ( in') Max Compressive Load ( Ibs) Test Compressive Strength( psi) Average psi) 1 01/30/2019 7 3.32 3.35 3.34 8.76 20,465 2,340 2 02/20/2019 28 3.31 3.35 3.33 8.71 26,915 3,090 3 02/20/2019 28 3.33 3.32 3.33 8.71 27,930 3,207 4 02/20/2019 28 3.34 3.32 3.33 8.71 27,130 3,115 3,140 Remarks Cylinders are tested at seven (7) days to get an early indication of the potential strength of the concrete, but the seven (7) day results are not to be used for concrete acceptance. When the compressive strength of the concrete has reached 70% of the specified strength, it is a reasonable practice to use this as an indication that 100% of the specified strength will be attained by twenty-eight (28) days. Note Test Results represent the Structural Element specified If an air test was not completed, that deviates from C31 procedure Sampled per ASTM C-172 - Yes Air Content Performed per ASTM C-173 or C-231 - No Unit Weight Performed per ASTM C-138 - N/A Slump Performed per ASTM C-143 - Yes Concrete Temperature Performed per ASTM C-1064 - Yes 5 FJ F1, Molded per C-31 - Yes Initially Cured per ASTM C-31 - Unknown L.- Capped in Lab to ASTM C-1231 Cured & Tested in Lab per ASTM C-31 & C-39 - Yes This Form Conforms With ASTM C-39 To establish a mutual protection to Universal's clients, the Public and ourselves, all reports are submitted as confidential property of our clients and authorization for publication of statements, conclusions or extracts from or regarding Universal's reports is reserved pending our written approval. This report shall not be reproduced, except in full, without the written approval of Universal Engineering Sciences. 1 of 1 Revised May 2018 UNIVERSAL ENGINEERING SCIENCES Consultants In: Geotechnical Engineering • Environmental Sciences Geophysical Services • Materials Testing • Threshold Inspection Building Code Administration, Compliance Inspection & Plan Review 3532 Maggie Blvd, Orlando, FL 32811 - P: 407.423.0504 - F: 407.423.3106 UES Project No: 0110.1800758.0000 Workorder No: 9433920-1 Report Date: 02/21/2019 In -Place Density Test Report Client: The Spanos Corporation UES Technician: Fernando Montalvo 2701 N. Rocky Point Drive, Suite 100 Date Tested: 02/19/2019 Tampa, FL 33607 Project: Lake Monroe Apartments, Materials Testing US 92 & West 1 st Street, Sanford, Seminole County, FL 32771 Type of Test: Area Tested: Road way (Stabilization ) (Permit Field: ASTM D-6938 Nuclear Gauge Method number 18-2508) Material: Stabilization Reference Datum: 0 = Top of Stabilization The tests below meet the 98% minimum compaction requirement. Laboratory: AASHTO T180 Modified Proctor Depth requirement is 12.00 inches Maximum Optimum Field Dry Field Soil Stab. Pass Test Density Moisture Density Moisture Compaction or No. Location of Test LBR pcf) pcf) N Fail 1 STA.24+00 110.3 11.2 111.9 12.0 101 12.25 Pass To establish a mutual protection to Universal's clients, the Public and ourselves, all reports are submitted as confidential property of our clients and authorization for publication of statements, conclusions or extracts from or regarding Universal's reports is reserved pending our written approval. Page 1 113 UNIVERSAL ENGINEERING SCIENCES Consultants In: Geotechnical Engineering • Environmental Sciences Geophysical Services • Materials Testing • Threshold Inspection Building Code Administration, Compliance Inspection & Plan Review 3532 Maggie Blvd, Orlando, FL 32811 - P: 407.423.0504 - F: 407.423.3106 UES Project No: 0110.1800758.0000 Workorder No: 9433920-2 Report Date: 02/21/2019 In -Place Density Test Report Client: The Spanos Corporation UES Technician: Fernando Montalvo 2701 N. Rocky Point Drive, Suite 100 Date Tested: 02/19/2019 Tampa, FL 33607 Project: Lake Monroe Apartments, Materials Testing US 92 & West 1st Street, Sanford, Seminole County, FL 32771 Type of Test: Area Tested: Parking Lot Betweeen Apartment Field: ASTM D-6938 Nuclear Gauge Method Pads B and C / Road way (Base ) Permit number 18-2508) Material: Limerock Laboratory: AASHTO T180 Modified Proctor Reference Datum: 0 = Top of Base Course Depth requirement is 8.00 inches The tests below meet the 98% minimum compaction requirement. Test No. Location of Test LBR Maximum Density pcf) Optimum Moisture Field Dry Density pcf) Field Moisture Soil Compaction Limerock Depth inch) Pass or Fail 2 Sta 24+00 120.7 9.5 121.8 11.9 101 8.25 Pass 3 25ft W and 25Ft N of the SE 120.7 9.5 122.2 12.6 101 8.50 Pass Corner Of Parking lot 4 25ft W and 100Ft N of the SE 120.7 9.5 122.9 12.0 102 8.25 Pass Corner Of Parking lot 5 25ft E and 25Ft N of the SW 120.7 9.5 120.9 10.9 100 8.75 Pass Corner Of Parking lot 6 25ft E and 100Ft N of the SW 120.7 9.5 123.1 12.7 102 8.50 Pass Corner Of Parking lot To establish a mutual protection to Universal's clients, the Public and ourselves, all reports are submitted as confidential property of our clients and authorization for publication of statements, conclusions or extracts from or regarding Universal's reports is reserved pending our written approval. Page 1 UNIVERSAL ENGINEERING SCIENCES Consultants In: Geotechnical Engineering • Environmental Sciences Geophysical Services • Materials Testing • Threshold Inspection Building Code Administration, Compliance Inspection & Plan Review 3532 Maggie Blvd, Orlando, FL 32811 - P: 407.423.0504 - F: 407.423.3106 UES Project No.: 0110.1800758.0000 Date Typed: March 01, 2019 Construction Materials Testing Services FIELD AND LABORATORY REPORT COVER PAGE Client: The Spanos Corporation 2701 N. Rocky Point Drive, Suite 100 Tampa, FL 33607 Project: Lake Monroe Apartments, Materials Testing US 92 & West 1 st Street, Sanford, Seminole County, FL 32771 As requested, Universal Engineering Sciences, Inc. (LIES) representative(s) performed construction materials testing and/or field inspection services on the above project. Testing results and/or inspection observations are reported on the attached sheets. The contents of this package are summarized below: Scope of Work Work Order No. Date Type of Report 9433926-1 02/27/2019 In -Place Density Test Report 9433926-2 02/27/2019 In -Place Density Test Report 9437683-1 02/20/2019 Grout Prism Test Specimens Report We hope this information is sufficient for your immediate needs. If you have any questions, please do not hesitate to contact the undersigned or Rosie Housein (extension 23078). Attachments (3) rh Sincerely, Universal Engineering Sciences, Inc. Certificate of Authorization No. 00000549 Fred Schmalzer 2019.03.05 07:37:44-05'00' Fred J. Schmalzer, P.E. Vice President - Construction Services STATE OF FLORIDA Professional Engineer No. 38818 This item has been electronically signed and sealed by Fred J. Schmalzer, P.E. using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. For the mutual protection of Universal's clients, the general public, and ourselves, our reports are submitted as the confidential property of our clients. Accordingly, authorization for reliance upon, or publication of, all orportions of this report is reserved pending our written approval. Revised May 2015 UNIVERSAL ENGINEERING SCIENCES Consultants In: Geotechnical Engineering • Environmental Sciences Geophysical Services • Materials Testing • Threshold Inspection Building Code Administration, Compliance Inspection & Plan Review 3532 Maggie Blvd, Orlando, FL 32811 - P: 407.423.0504 - F: 407.423.3106 UES Project No: 0110.1800758.0000 Workorder No: 9433926-1 Report Date: 03/01/2019 In -Place Density Test Report Client: The Spanos Corporation UES Technician: Fernando Montalvo 2701 N. Rocky Point Drive, Suite 100 Date Tested: 02/27/2019 Tampa, FL 33607 Project: Lake Monroe Apartments, Materials Testing US 92 & West 1st Street, Sanford, Seminole County, FL 32771 Type of Test: Area Tested: Sanitary Structure (Permit Number 18 Field: ASTM D-2937 Drive Cylinder Method 2508) Material: Backfill Laboratory: ASTM D1557 Modified Proctor Reference Datum: 0 = Bottom of Sanitary Structure The tests below meet the 98% minimum compaction requirement. Test No. Location of Test Range Maximum Density pcf) Optimum Moisture M Field Dry Density pcf) Field Moisture N Soil Compaction M Pass or Fail 1 Structure 1 4+5 ft 111.5 11.3 111.6 7.8 100 Pass 2 Structure S7 0+1 ft 111.5 11.3 111.9 8.0 100 Pass 3 Structure S7 1+2 ft 111.5 11.3 110.6 7.1 99 Pass 4 Structure S7 2+3 ft 111.5 11.3 110.0 7.3 99 Pass 5 Structure U8 0+1 ft 111.5 11.3 111.7 8.8 100 Pass 6 Structure U8 1+2 ft 111.5 11.3 111.2 8.1 100 Pass 7 Structure U8 2+3 ft 111.5 11.3 110.4 7.3 99 Pass 8 Structure U8 3+4 ft 111.5 11.3 109.9 7.1 99 Pass 9 Structure V10 0+1 ft 111.5 11.3 112.0 7.8 100 Pass 10 Structure V10 1+2 ft 111.5 11.3 111.6 7.2 100 Pass 11 Structure V10 2+3 ft 111.5 11.3 110.0 7.0 99 Pass 12 Structure V7 0+1 ft 111.5 11.3 111.9 8.3 100 Pass 13 Structure V7 1+2 ft 111.5 11.3 110.3 7.4 99 Pass 14 Structure V7 2+3 ft 111.5 11.3 111.4 7.9 100 Pass 19 Structure O 0+1 ft 111.5 11.3 111.7 8.0 100 Pass 20 Structure O 1+2 ft 111.5 11.3 110.6 7.1 99 Pass 21 IStructure O 2+3 ft 1 111.5 1 11.3 1 112.1 1 8.1 1 101 1 Pass To establish a mutual protection to Universal's clients, the Public and ourselves, all reports are submitted as confidential property of our clients and authorization for publication of statements, conclusions or extracts from or regarding Universal's reports is reserved pending our written approval. Page 1 3 UNIVERSAL ENGINEERING SCIENCES Consultants In: Geotechnical Engineering • Environmental Sciences Geophysical Services • Materials Testing • Threshold Inspection Building Code Administration, Compliance Inspection & Plan Review 3532 Maggie Blvd, Orlando, FL 32811 - P: 407.423.0504 - F: 407.423.3106 UES Project No: 0110.1800758.0000 Workorder No: 9433926-2 Report Date: 03/01/2019 In -Place Density Test Report Client: The Spanos Corporation UES Technician: Fernando Montalvo 2701 N. Rocky Point Drive, Suite 100 Date Tested: 02/27/2019 Tampa, FL 33607 Project: Lake Monroe Apartments, Materials Testing US 92 & West 1 st Street, Sanford, Seminole County, FL 32771 Type of Test: Area Tested: Sanitary Pipe (Permit Number 18- Field: ASTM D-2937 Drive Cylinder Method 2508) Material: Backfill Laboratory: ASTM D1557 Modified Proctor Reference Datum: 0 = Springline of Pipe The tests below meet the 98% minimum compaction requirement. Maximum Optimum Field Dry Field Soil Pass Test Density Moisture Density Moisture Compaction or No. Location of Test Range pcf) pcf) Fail 15 V10 to V7 6"VC 0-1 ft 111.5 11.3 111.4 8.0 100 Pass 16 V10 to V7 6"VC 0+1 ft 111.5 11.3 111.1 7.6 100 Pass 17 V10 to V7 6"VC 1+2 ft 111.5 11.3 110.3 7.0 99 Pass 18 V10 to V7 6"VC 2+3 ft 111.5 11.3 110.1 6.9 99 Pass To establish a mutual protection to Universal's clients, the Public and ourselves, all reports are submitted as confidential property of our clients and authorization for publication of statements, conclusions or extracts from or regarding Universal's reports is reserved pending our written approval. Page 1 Project No: 000UNIVERSAL943763-1 CT.0220ReportNo.: 9437683-1 CT 022019 ENGINEERING SCIENCESED Wo rko rd arN o.: 9437683 Lab No.: 19M632-C Consultants In: Geotechnical Engineering • Environmental Sciences Date 1st Issue: February 28, 2019 Geophysical Services • Materials Testing • Threshold Inspection Building Code Administration, Compliance Inspection & Plan Review 3532 Maggie Blvd, Orlando, FL 32811 - P: 407.423.0504 - F: 407.423.3106 Compressive Strength of Grout Prism Test Specimens ASTM C-1019) Client The Spanos Corporation 2701 N. Rocky Point Drive, Suite 100, Tampa, FL 33607 Project Lake Monroe Apartments, Materials Testing US 92 & West 1st Street, Sanford, Seminole County, FL 32771 Structural Element: Cell Fill Sample Location: Third Floor Stair Tower (Permit # 17-1582) - Sampled at Southeast Corner of Wall Set# 1 of 1 Sample From: Concrete Truck General Information General Contractor: The spanos Subcontractor: Supplier: Maschmeyer Concrete Truck No.: 2843 Ticket No.: 1202802 Mix Design: 30550000 Admixture: NIS Sample By: DiJon Davis On 02/20/2019 Specified Strength / Sampling Times Specified Strength: 3000 psi @ 28 days Mix Design Strength: 3000 psi @ 28 days Water Added at Site: N/A Time Batched: 8:37 AM Time Sampled: 9:55 AM Weather Condition: Partly Cloudy Field Test Results At Lab On or Before: 02/21/2019 Placement Information Truck Load: 3.00 cu yds. Cumulative Quantity: 3.00 cu yds. Total Placement for the Day: 3.00 cu yds. Air Content: N/A Slump: 4.50 inches Ambient Temp: 70 °F I Concrete Temp: 76 °F Unit Weight: N/A Results of Laboratory Testing Test Results Date Tested Age Days Type Of Fracture Actual Dimen.1 in) Actual Dimen.2 in) Avg. Dimen. in) Test X-Sect. Area (in2) Max Compressive Load (lbs) Test Compressive Strength(psi) Average psi) 1 02/27/2019 7 3.31 3.34 3.33 11.06 25,650 2,320 2 03/20/2019 28 3 03/20/2019 28 4 03/20/2019 28 1 - Remarks Grout Prisms are tested at seven (7) days to get an early indication of the potential strength of the concrete, but the seven (7) day results are not to be used for concrete acceptance. When the compressive strength of the concrete has reached 70% of the specified strength, it is a reasonable practice to use this as an indication that 100% of the specified strength will be attained by twenty-eight (28) days. Note Test Results represent the Structural Element specified If an air test was not completed, that deviates from C31 procedure Tested in Lab to C39 Cured in C-511 Test Not performed per C-1019, Grout Boxes were used To establish a mutual protection to Universal's clients, the Public and ourselves, all reports are submitted as confidential property of our clients and authorization forpublication of statements, conclusions or extracts from or regarding Universal's reports is reserved pending our written approval. This report shall not be reproduced, except in full, without the written approval of Universal Engineering Sciences. 1 of 1 Revised May 2018 0000DESProjectNo.: UNIVERSAL Date Typed: February 22, 2019 ENGINEERING SCIENCES Consultants In: Geotechnical Engineering • Environmental Sciences Geophysical Services • Materials Testing • Threshold Inspection03BuildingCodeAdministration, Compliance Inspection & Plan Review 3532 Maggie Blvd, Orlando, FL 32811 - P: 407.423.0504 - F: 407.423.3106 Construction Materials Testing Services FIELD AND LABORATORY REPORT COVER PAGE Client: The Spanos Corporation 2701 N. Rocky Point Drive, Suite 100 Tampa, FL 33607 Project: Lake Monroe Apartments, Materials Testing US 92 & West 1st Street, Sanford, Seminole County, FL 32771 As requested, Universal Engineering Sciences, Inc. (UES) representative(s) performed construction materials testing and/or field inspection services on the above project. Testing results and/or inspection observations are reported on the attached sheets. The contents of this package are summarized below: Scope of Work Work Order No. Date Type of Report 9433922-1 02/21/2019 In -Place Density Test Report We hope this information is sufficient for your immediate needs. If you have any questions, please do not hesitate to contact the undersigned or Rosie Housein (extension 23078). Attachments (1) rh Sincerely, Universal Engineering Sciences, Inc. Certificate of Authorization No. 00000549 Fred Schmalzer r`J•cfUSF F. 2019.03.05 07: 38:15 -05 00 Fred J. Schmalzer, P.E. Vice President - Construction Services STATE OF FLORIDA Professional Engineer No. 38818 This item has been electronically signed and sealed by Fred J. Schmalzer, P.E. using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. For the mutual protection of Universal's clients, the general public, and ourselves, our reports are submitted as the confidential property of our clients. Accordingly, authorization for reliance upon, or publication of, all or portions of this report is reserved pending our written approval. Revised May 2015 3 UNIVERSAL ENGINEERING SCIENCES Consultants In: Geotechnical Engineering • Environmental Sciences Geophysical Services • Materials Testing • Threshold Inspection Building Code Administration, Compliance Inspection & Plan Review 3532 Maggie Blvd, Orlando, FL 32811 - P: 407.423.0504 - F: 407.423.3106 UES Project No: 0110.1800758.0000 Workorder No: 9433922-1 Report Date: 02/22/2019 In -Place Density Test Report Client: The Spanos Corporation LIES Technician: Fernando Montalvo 2701 N. Rocky Point Drive, Suite 100 Date Tested: 02/21/2019 Tampa, FL 33607 Project: Lake Monroe Apartments, Materials Testing US 92 & West 1 st Street, Sanford, Seminole County, FL 32771 Type of Test: Area Tested: Storm Structure (Permit Number 18- Field: ASTM D-2937 Drive Cylinder Method 2508) Material: Backfill Laboratory: ASTM D1557 Modified Proctor Reference Datum: 0 = Bottom of Storm Inlet Structure Tha tpctq halnw mPPt the PR% minimum compaction reauirement. Test No. Location of Test Range Maximum Density pcf) Optimum Moisture Field Dry Density pcf) Field Moisture Soil Compaction Pass or Fail 1 S-65 0+1 ft 111.5 11.3 111.8 8.8 100 Pass 2 S-65 1 +2 ft 111.5 11.3 110.5 8.0 99 Pass 3 S-65 2+3 ft 111.5 11.3 110.1 7.7 99 Pass 4 S-67 2+3 ft 111.5 11.3 110.7 8.3 99 Pass 5 S-69 4+5 ft 111.5 11.3 111.1 8.0 100 Pass 6 S-69 5+6 ft 111.5 11.3 110.7 7.9 99 Pass 7 S-69 6+7 ft 111.5 11.3 110.0 7.1 99 Pass 8 S-75 0+1 ft 111.5 11.3 111.9 8.7 100 Pass 9 S-75 1+2 ft 111.5 11.3 110.6 7.6 99 Pass 10 S-75 2+3 ft 1 111.5 1 11.3 1 109.9 7.0 99 1 Pass To establish a mutual protection to Universal's clients, the Public and ourselves, all reports are submitted as confidential property ofour clients and authorization for publication of statements, conclusions or extracts from or regarding Universal's reports is reserved pending our written approval. Page 1