Loading...
469, 465, 461, 457, 453, 449, 445, 441 Merry Brook Cir (fr sp)Q BIRCH UNIT SPIGOT LOCATION DETAIL vs• = r -o• Garage F--------------------�1 I �♦ Qi i� I I i I max` I 114 I � I BR filig-) --- ----------- REDWOOD UNIT SPIGOT LOCATION DETAIL CONC, 5L,45 FLOOR GARAGE INTERIOR CONCRETE SLAB RE IFORCEID. 2�` MIN. STEEL SLEEVE - PIPE SOCK W CPVC 900 ELL------- Fire LLS Ft. 8prr,l w% r% EXTERIOR W, CPVC FIRE SPRINKLER SPIGOT DETAIL SCALE, 1/2' = Y Garage -----------------------------------------� -I f I ---------------------------------I---- I U L — — — — — — — — — ` I I U WILLOW UNIT SPIGOT LOCATION DETAIL C A1C,E T lt—_07N 5 E FAL,4N FROM SUPPLY * DESIGN AND INSTALLATION TO BE IN ACCORDANCE WITH 2010 EDITION OF NFPA 13D, LOCAL PLUMBING CODE AND ALL APPLICABLE LOCAL AND STATE CODES. * ALL PLASTIC PIPE 3/4" THROUGH 2YQ SHALL BE UL LISTED OR FM APPROVED CPVC MANUFACTURED IN ACCORDANCE WITH ASTM F442. 0 ALL PLASTIC FITTINGS SHALL BE UL LISTED OR FM APPROVED CPVC MANUFACTURED IN ACCORDANCE WITH ASTM F438, ASTM F439 OR ASTM F1970. * ALL CPVC PIPE AND FITTINGS SHALL BE ASSEMBLED USING "ONE STEP" 500 CEMENT. * ALL STEEL PIPE WILL BE SCHEDULE 40 HOT DIPPED GALVANIZED MANUFACTURED IN ACCORDANCE WITH ASTM A795 OR ASTM A-53. 1N ALL THREADED FITTINGS SHALL BE GALVANIZED MALLEABLE IRON CLASS 150 OR CLASS 300 AND SHALL BE MANUFACTURED IN ACCORDANCE WITH ANSI B16.3 AND ASTM A 153. * ALL GROOVED FITTINGS SHALL BE UL LISTED OR FM APPROVED AND MANUFACTURED IN ACCORDANCE WITH ASTM A-536 FOR DUCTILE IRON OR ASTM A-47 FOR MALLEABLE IRON. * BRASS PIPE AND FITTINGS WILL BE UTILIZED ONLY AS REQUIRED BY LOCAL WATER PURVEYOR. (N WAFS TO PROVIDE CPVC COMPATIBLE AGAVE 14 GAUGE TRACING WIRE ON ALL UNDERGROUND PIPING. * UNDERGROUND MAINS AND LEAD-INS SHALL BE FLUSHED PER FLOW RATES IN NFPA 24 PRIOR TO CONNECTING TO OVERHEAD PIPING. * ALL PIPING SHALL BE BURIED A MINIMUM OF 30 INCHES BELOW GRADE TO THE TOP OF THE PIPE PER WAFS COMPANY STANDARDS. IN ALL PIPING UNDER ROADWAYS SHALL BE BURIED A MINIMUM OF 36 INCHES BELOW GRADE TO THE TOP OF THE PIPE. * ALL PIPING SHALL BE INSPECTED AND APPROVED BY PROPER AUTHORITIES PRIOR TO COVERING. 1N ALL PIPING SHALL BE TESTED AT 200 PSI FOR 2 HOURS PER WAFS STANDARDS. * VALVES SHALL NOT BE REQUIRED TO BE MONITORED PER FLORIDA BUILDING CODE 903.4 (1). * ALL PAINTING OF PIPE AS REQUIRED IS BY OTHERS. * WAFS TO PROVIDE ALL NECESSARY SIGNAGE INCLUDING BUT NOT LIMITED TO VALVES, HYDRAULIC PLACARDS, AND INSPECTION TAGS AS REQUIRED BY FS. 633. * SEE CIVIL DRAWINGS FOR DETAILS OF PIPING PRIOR TO WAYNE AUTOMATIC'S POINT OF CONNECTION. * PER FLORIDA STATUTE 633.539, ALL UNDERGROUND FROM THE POINT OF SERVICE TO T-0" AFF SHALL BE INSTALLED BY ONE CLASS I, II OR V LICENSED CONTRACTOR. * ALL FERROUS PIPE AND FITTINGS SHALL BE EXTERNALLY WRAPPED AND COATED WITH A BITUMINOUS COATING. * CLEARANCES AROUND FIRE PROTECTION APPLIANCES SHALL BE PROVIDED AS REQUIRED BY LOCAL AUTHORITY. O WILKINS (M SMITH COOPER 110 PROVALUE ANVIL SOUTHERN VALVE IMPORT WARD V GALV, THREADED PLUG O Y4' BRONZE 3—WAY VALVE13 3' ' WATER PRESSURE GAUGE Y4' X 3' GALV, NIPPLE O —� h' X y' GALV, BUSHING O W,A,F,S. TO TIE INTO THE OCTAVE METER. 2'X2'XJ'06 GALV, REDUCING TEE GR ® NFPA 13D 2010 TOWNHOME UNDERGROUND GENERAL NOTES E SCALD NONE Fka sp *Mmm km. 00675N REV, 2.0 SPRINrKLERS7 SPACING I i r -QUANTITY --i SPRINKLERS MAXIMUM I MINIMUM (COMMENTS I IIISYMBIIST12ND13RD14THISIN 1SIZE1 K lTEMPlM0DEL TOTAL PER FLOOR AL THIS SHEETS DATE I SUBMITTAIS 1BY 09/13/16 1 QA REVIEW 1 MPF N0. I DATE I REVISIONS I BY 11 /,A I w 13K IK 14GA. COPPER LOCATING WIRE (AGAVE WIRE) FINISHED GRADE 7l1" MAX C-900 FIRE MAIN OR CPVC FIRE MAIN =1" MAX F_LOCATING WIRE T— NOTES: 1. PVC PIPE SHALL REQUIRE INSULATED METALLIC LOCATING WIRE (14 GAUGE COPPER AGAVE WIRE) CAPABLE OF DETECTION BY A CABLE LOCATOR AND SHALL BE BURIED DIRECTLY ABOVE THE CENTERLINE OF THE PIPE. 2. LOCATING WIRE SHALL TERMINATE AT THE TOP OF EACH VALVE BOX AND BE CAPABLE OF EXTENDING 12" ABOVE TOP OF BOX IN SUCH A MANNER AS TO NOT INTERFERE WITH VALVE OPERATION. 3. USE FGG/BM COMPATIBLE DUCT TAPE AS NECESSARY TO HOLD WIRE DIRECTLY ON THE TOP OF THE PIPE. Aw= i I I Fie 8prW&m Ino. MANUFACTURER LIST 1! TYCO NIBCO SPEARS 12 TYCO ANVIL VICTAULIC SHURJOINT 2' DOUBLE DETECTOR CHECK BACKFLOW PREVENTER W/ BUTTERBALL VALVES. (SEE MANUF, SPEC SHEET FOR FRICTION LOSS INFORMATION) 2' X 3' GALV, NIPPLE 2' X 4' GALV, TQ --THRD, X GRV, 13 FPPI NIBCO UNITED BRASS 1a ARGCO FPPI VIKING ASHCROFT 1s (IN ACCORDANCE W/ ANSI/ASTM A-53) 2' GALV, �z GRV, COUPLING 2' GALV, — O THREADED PLUG 2' GALV, Us TEE 00185N n 2' X 34'-i = H iTf 1TfIL1_ r=.l r 1 15 GALV, SCH-40 =T1111 �I�I I I� I I 2' GALV, BFl WF,S, POINT OF O 90' ELL CONNECTION, 2' X 3' O GALV, NIPPLE TO 2' CPVC 1! # CPVC SYSTEM » FEMALE ADAPTER 2' x 1)�' CPVC 7 BUSHING 2' WILKINS 950XLTDABF DOUBLE DETECTOR CHECK BACKFLOW PREVENTER DETAIL lkywr SCALD 1/2' = 1' Fin Sp kmwol km tllilrrr rWd+++�mn+in yM Automatic Fire Sprinklers, Inc. MAIN OFFICE — ORLANDO, FLORIDA 222 CAPITOL COURT OCOEE" FLORIDA 34761 PHONE: (407) 656-3030 FAX: (407) 658-9026 JA0MMVl1E, FL TAMPA. FL I F'owANO BEACH, r -L 11326 DISTRIBUTION AVE WEST 3226 CHERRY PALM DRIVE 3121 NW 16TH TERRACE JACKSONVILLE FL 32256-2745 TAMPA, FL 33819-8337 POMPANO BEACH, FL 33084-1408 PHONE: (904) M-3030 PHONE (813) 830-0303 PHONE (954) ST7-3030 FAX: (904) 2BB-M4 FAX: (813) 830-0312 FAX: (954) 817-9424 FT. MYM FL COPILORD. Nc STATE LICENSES: 4883 LAREDO AVE 4370 MOTORSPORT DRIVE NC SPRFAaXR 29745 FT. MYERS, FL 33905-4924 CONCORD, NC 28027-8977 NC ALARA: 29222 SP LV PHONE: (239) 433-3030 PHONE: (7D4) 782-3032 SC SPRNCLER 1118 FAX: (239) 433-3263 FAX: (704) 795-8838 SC ALARA: 3385 00581L LOTS 139-146 >i TH RIVE 0 BR KE 00 TOWNHOMES OME S WHITE CEDAR ROAD SANFORD FL 32771 � TAYLOR MORRISON HOMES 151 SOUTHHALL LANE, SUITE 200 MAITLAND, FL 32751 FIRE PROTECTION SITE NOTES & DETAILS PLAN IMPORTANT OWNER INFORMATION GRAPHICS ELEMENTS (VOTE WATER SUPPLY INFORMATION DESIGN CRITERIA CITY OF SANFORD THIS DRAWING IS BASED ON THE OWNER'S ACCEPTANCE OF THE CURRENTLY ADOPTED R SPRINKLER RAW NG H P DRAWINGS MAY INCLUDE FIRE S RI LER D I S AND S❑ D I CL E BACKGROUND DRAWINGS OR GRAPHICS BORROWED FROM THE ARCHITECTURAL, CIVIL, CENTER OF TILE JOB? [:] YES W NO I CENTER ON FIXTURES JOB? Q YES NO SHEET t PS02 CONSTRUCTION TYPE, V -B OCCUPANCY R-3 EDITION (EITHER STATE OR LOCAL) OF NFPA 25 AS THE APPLICABLE STANDARD FOR THE INSPECTION, TESTING AND MAINTENANCE OF WATER BASED FIRE PROTECTION STRUCTURAL, OR MEP DRAWINGS. THESE REFERENCE BACKGROUND ELEMENTS ARE FOR DROUGHT DR FIRE PUMP DESIGN SYSTEM /AREA GENERAL INFORMATION OR CONTEXT ONLY AND THE FIRE SPRINKLER ENGINEER DOES # SYSTEMS. PER SECTION 4.1, THE RESPONSIBILITY FOR PROPERLY MAINTAINING A NOT ACCEPT ANY RESPONSIBILITY FOR THESE ELEMENTS. THE FIRE SPRINKLER ACTUAL EXTRAPiD.ATED WATER BASED FIRE PROTECTION SYSTEM SHALL BE THAT OF THE OWNER. IF THE ENGINEER IS ONLY RESPONSIBLE FOR THOSE PORTIONS OF THE FIRE SPRINKLER DRAWINGS DEPICTING FIRE SPRINKLER SCOPES OF WORK. REFER TO APPROVED (AS REQ'D BY AHD SIZE( GPM Q PSI HAZARD CLASS BUILDING OWNER HAS NOT RECEIVED A COPY OF THIS PAMPHLET AND/OR IS NOT FAMILIAR WITH THE OPERATION AND MAINTENANCE OF THIS SYSTEM, PLEASE CONTACT THE NEAREST OFFICE OF WAYNE AUTOMATIC FIRE SPRINKLERS, INC, ARCHITECTURAL, STRUCTURAL, MEP OR CIVIL DRAWINGS FOR AUTHORITATIVE EXPRESSIONS OF BACKGROUND INFORMATION THAT MAY BE UTILIZED IN FIRE STATIC PRESSURE 66 PSI HYDRANT ELEV, 2' k SI SPRINKLERS 1N SPRINKLER DRAWINGS OR DETAILS DESIGN AREA - - — - y-- -- --_ - --- - - - - RESIDUAL PRESS 56 PSI DATE OF TEST 09/06/16 NINDIUM DENSITY CPVC COMPATIBILITY NOTICE _— j CPVC FIRE SPRINKLER PIPING SYSTEMS HAVE BEEN USED SUCCESSFULLY FOR MORE THAN RE PRODUCTS FLOW IN GPM 1010 GPI'] TIME OF TEST 8+00 AM DESIGN AREA S.F. 20 YEARS IN NEW CONSTRUCTION, -PIPE AND REPAIR. CPVC ARE IDEALLY SUITED FOR THESE APPLICATIONS DUE TO THEIR OUTSTANDING CORROSION RESISTANCE, OCCASIONALLY, HOWEVER, CPVC CAN BE DAMAGED BY CONTACT WITH CHEMICALS FOUND IN SOME CONSTRUCTION MATERIALS (IE- SOME WIRES, FLUX, PITOT READING 36 PSI NUMBER OF PORTS FLOWED I PSI REND E BASR PETROLEUM BASED PRODUCTS, ETC.) AND ANCILLARY PRODUCTS SUCH AS THREAD SEALANTS, LEAK DETECTORS, FIRESTOPS, ETC, ANY PRODUCT THAT COMES IN CONTACT WITH CPVC SPRINKLER PIPE MUST BE. EVALUATED IN ACCORDANCE WITH GPM REWD E BASR THE SYSTEM COMPATIBILITY PROGRAM AS FOUND AT WWW.SYSTEMCOMPATIBLE.COM - -- -- ---- --- ,, TEST PROVIDED BY WAYNE AUTOMATIC FIRE SPRINKLERS, TNC. PSI READ a TEST C O P YR I G H T GN REQ'D t TEST Q ALL DOCUMENTS, INCLUDING ORIGINAL DRAWINGS, SPECIFICATIONS, FIELD NOTES, N ESTIMATES AND DATA, INCLUDING COMPUTER PROGRAMS PURSUANT TO THIS PROJECT ELEVATIONE HIGHEST ARE AND WILL REMAIN THE PROPERTY OF WAYNE AUTOMATIC FIRE SPRINKLERS, INC. I:-:(WAFS) AS INSTRUMENTS OF SERVICE. THEY ARE NOT INTENDED, NOR REPRESENTED SPRDKLER TO BE SUITABLE FOR RE -USE BY THE CLIENT, OR OTHERS, ON EXTENSION OF THIS FOSE PROJECT, OR FOR ANY OTHER PROJECT. ANY REUSE, OR ADAPTATION OF THE HYDRANT INSIDE/OUTSIDE NFORMATION CONTAINED HEREIN, WITHOUT SPECIFIC WRITTEN PERMISSION FROM WAFS WILL BE AT THE CLIENTS SOLE RISK, WITHOUT LIABILITY, OR LEGAL EXPOSURE TO LOCATION OR TEST HYDRANT LOCATED ON WHITE CEDAR ROAD to WAFS, AND WILL ENTITLE WAFS TO FURTHER COMPENSATION AT RATES TO BE NUMBER DO(ESTIC DEMAND r-1 O AGREED ON BETWEEN WAFS AND THE CLIENT. THE CLIENT SHALL ALSO INDEMNIFY AND HOLD WAFS HARMLESS FROM ANY AND ALL CLAIMS, DAMAGES, LOSSES AND j EXPENSES, INCLUDING ATTORNEYS FEES RESULTING FROM ANY SUCH PERMISSIONS, rn FROM SUPPLY * DESIGN AND INSTALLATION TO BE IN ACCORDANCE WITH 2010 EDITION OF NFPA 13D, LOCAL PLUMBING CODE AND ALL APPLICABLE LOCAL AND STATE CODES. * ALL PLASTIC PIPE 3/4" THROUGH 2YQ SHALL BE UL LISTED OR FM APPROVED CPVC MANUFACTURED IN ACCORDANCE WITH ASTM F442. 0 ALL PLASTIC FITTINGS SHALL BE UL LISTED OR FM APPROVED CPVC MANUFACTURED IN ACCORDANCE WITH ASTM F438, ASTM F439 OR ASTM F1970. * ALL CPVC PIPE AND FITTINGS SHALL BE ASSEMBLED USING "ONE STEP" 500 CEMENT. * ALL STEEL PIPE WILL BE SCHEDULE 40 HOT DIPPED GALVANIZED MANUFACTURED IN ACCORDANCE WITH ASTM A795 OR ASTM A-53. 1N ALL THREADED FITTINGS SHALL BE GALVANIZED MALLEABLE IRON CLASS 150 OR CLASS 300 AND SHALL BE MANUFACTURED IN ACCORDANCE WITH ANSI B16.3 AND ASTM A 153. * ALL GROOVED FITTINGS SHALL BE UL LISTED OR FM APPROVED AND MANUFACTURED IN ACCORDANCE WITH ASTM A-536 FOR DUCTILE IRON OR ASTM A-47 FOR MALLEABLE IRON. * BRASS PIPE AND FITTINGS WILL BE UTILIZED ONLY AS REQUIRED BY LOCAL WATER PURVEYOR. (N WAFS TO PROVIDE CPVC COMPATIBLE AGAVE 14 GAUGE TRACING WIRE ON ALL UNDERGROUND PIPING. * UNDERGROUND MAINS AND LEAD-INS SHALL BE FLUSHED PER FLOW RATES IN NFPA 24 PRIOR TO CONNECTING TO OVERHEAD PIPING. * ALL PIPING SHALL BE BURIED A MINIMUM OF 30 INCHES BELOW GRADE TO THE TOP OF THE PIPE PER WAFS COMPANY STANDARDS. IN ALL PIPING UNDER ROADWAYS SHALL BE BURIED A MINIMUM OF 36 INCHES BELOW GRADE TO THE TOP OF THE PIPE. * ALL PIPING SHALL BE INSPECTED AND APPROVED BY PROPER AUTHORITIES PRIOR TO COVERING. 1N ALL PIPING SHALL BE TESTED AT 200 PSI FOR 2 HOURS PER WAFS STANDARDS. * VALVES SHALL NOT BE REQUIRED TO BE MONITORED PER FLORIDA BUILDING CODE 903.4 (1). * ALL PAINTING OF PIPE AS REQUIRED IS BY OTHERS. * WAFS TO PROVIDE ALL NECESSARY SIGNAGE INCLUDING BUT NOT LIMITED TO VALVES, HYDRAULIC PLACARDS, AND INSPECTION TAGS AS REQUIRED BY FS. 633. * SEE CIVIL DRAWINGS FOR DETAILS OF PIPING PRIOR TO WAYNE AUTOMATIC'S POINT OF CONNECTION. * PER FLORIDA STATUTE 633.539, ALL UNDERGROUND FROM THE POINT OF SERVICE TO T-0" AFF SHALL BE INSTALLED BY ONE CLASS I, II OR V LICENSED CONTRACTOR. * ALL FERROUS PIPE AND FITTINGS SHALL BE EXTERNALLY WRAPPED AND COATED WITH A BITUMINOUS COATING. * CLEARANCES AROUND FIRE PROTECTION APPLIANCES SHALL BE PROVIDED AS REQUIRED BY LOCAL AUTHORITY. O WILKINS (M SMITH COOPER 110 PROVALUE ANVIL SOUTHERN VALVE IMPORT WARD V GALV, THREADED PLUG O Y4' BRONZE 3—WAY VALVE13 3' ' WATER PRESSURE GAUGE Y4' X 3' GALV, NIPPLE O —� h' X y' GALV, BUSHING O W,A,F,S. TO TIE INTO THE OCTAVE METER. 2'X2'XJ'06 GALV, REDUCING TEE GR ® NFPA 13D 2010 TOWNHOME UNDERGROUND GENERAL NOTES E SCALD NONE Fka sp *Mmm km. 00675N REV, 2.0 SPRINrKLERS7 SPACING I i r -QUANTITY --i SPRINKLERS MAXIMUM I MINIMUM (COMMENTS I IIISYMBIIST12ND13RD14THISIN 1SIZE1 K lTEMPlM0DEL TOTAL PER FLOOR AL THIS SHEETS DATE I SUBMITTAIS 1BY 09/13/16 1 QA REVIEW 1 MPF N0. I DATE I REVISIONS I BY 11 /,A I w 13K IK 14GA. COPPER LOCATING WIRE (AGAVE WIRE) FINISHED GRADE 7l1" MAX C-900 FIRE MAIN OR CPVC FIRE MAIN =1" MAX F_LOCATING WIRE T— NOTES: 1. PVC PIPE SHALL REQUIRE INSULATED METALLIC LOCATING WIRE (14 GAUGE COPPER AGAVE WIRE) CAPABLE OF DETECTION BY A CABLE LOCATOR AND SHALL BE BURIED DIRECTLY ABOVE THE CENTERLINE OF THE PIPE. 2. LOCATING WIRE SHALL TERMINATE AT THE TOP OF EACH VALVE BOX AND BE CAPABLE OF EXTENDING 12" ABOVE TOP OF BOX IN SUCH A MANNER AS TO NOT INTERFERE WITH VALVE OPERATION. 3. USE FGG/BM COMPATIBLE DUCT TAPE AS NECESSARY TO HOLD WIRE DIRECTLY ON THE TOP OF THE PIPE. Aw= i I I Fie 8prW&m Ino. MANUFACTURER LIST 1! TYCO NIBCO SPEARS 12 TYCO ANVIL VICTAULIC SHURJOINT 2' DOUBLE DETECTOR CHECK BACKFLOW PREVENTER W/ BUTTERBALL VALVES. (SEE MANUF, SPEC SHEET FOR FRICTION LOSS INFORMATION) 2' X 3' GALV, NIPPLE 2' X 4' GALV, TQ --THRD, X GRV, 13 FPPI NIBCO UNITED BRASS 1a ARGCO FPPI VIKING ASHCROFT 1s (IN ACCORDANCE W/ ANSI/ASTM A-53) 2' GALV, �z GRV, COUPLING 2' GALV, — O THREADED PLUG 2' GALV, Us TEE 00185N n 2' X 34'-i = H iTf 1TfIL1_ r=.l r 1 15 GALV, SCH-40 =T1111 �I�I I I� I I 2' GALV, BFl WF,S, POINT OF O 90' ELL CONNECTION, 2' X 3' O GALV, NIPPLE TO 2' CPVC 1! # CPVC SYSTEM » FEMALE ADAPTER 2' x 1)�' CPVC 7 BUSHING 2' WILKINS 950XLTDABF DOUBLE DETECTOR CHECK BACKFLOW PREVENTER DETAIL lkywr SCALD 1/2' = 1' Fin Sp kmwol km tllilrrr rWd+++�mn+in yM Automatic Fire Sprinklers, Inc. MAIN OFFICE — ORLANDO, FLORIDA 222 CAPITOL COURT OCOEE" FLORIDA 34761 PHONE: (407) 656-3030 FAX: (407) 658-9026 JA0MMVl1E, FL TAMPA. FL I F'owANO BEACH, r -L 11326 DISTRIBUTION AVE WEST 3226 CHERRY PALM DRIVE 3121 NW 16TH TERRACE JACKSONVILLE FL 32256-2745 TAMPA, FL 33819-8337 POMPANO BEACH, FL 33084-1408 PHONE: (904) M-3030 PHONE (813) 830-0303 PHONE (954) ST7-3030 FAX: (904) 2BB-M4 FAX: (813) 830-0312 FAX: (954) 817-9424 FT. MYM FL COPILORD. Nc STATE LICENSES: 4883 LAREDO AVE 4370 MOTORSPORT DRIVE NC SPRFAaXR 29745 FT. MYERS, FL 33905-4924 CONCORD, NC 28027-8977 NC ALARA: 29222 SP LV PHONE: (239) 433-3030 PHONE: (7D4) 782-3032 SC SPRNCLER 1118 FAX: (239) 433-3263 FAX: (704) 795-8838 SC ALARA: 3385 00581L LOTS 139-146 >i TH RIVE 0 BR KE 00 TOWNHOMES OME S WHITE CEDAR ROAD SANFORD FL 32771 � TAYLOR MORRISON HOMES 151 SOUTHHALL LANE, SUITE 200 MAITLAND, FL 32751 FIRE PROTECTION SITE NOTES & DETAILS PLAN MICKEY FERGUSON F 144 SEPTEMBER 12, 2016 CITY OF SANFORD 84194 Oh CENTER OF TILE JOB? [:] YES W NO I CENTER ON FIXTURES JOB? Q YES NO SHEET t PS02 CONSTRUCTION TYPE, V -B OCCUPANCY R-3 e -i (N 00 O O .-I UJ O izM a „ i p NOTE tTHESE CURE TMIES ARE FOR NEW CONSTRUCTION. F: GLUING INTO EXISTING DIDWP_ c Ii IrU AC N.II TUC rACC nC r1 rr-IAIC rl n]Ac c C Txunt n n OC A LAIKELAa CURE TIMES WITH ONE 200 PSI (MAXIMUM) TEST STEP SOLVENT CEMENT PRESSURE (SEE NOTE U 'R' @ GREATER THAN 100 PSI PIPE SIZE INCHES AMBIENT TEMPERATURE DURING CURE PERIOD 60'F TO 120'F 40'F TO 59'F 0'17 TO 39'F %' 45 MIN, 1.5 HR, 24 HR. 1' 45 MIN, 1.5 HR. 24 HR, 134' 1.5 HR, 16 HR, 120 HR, lY2• 1.5 HR, 16 HR. 120 HR, 2' 6 HR, 36 HR. SEE NOTE 2 2W 8 HR, 72 HR, SEE NOTE 2 3' 8 HR, 72 HR. SEE NOTE 2 p NOTE tTHESE CURE TMIES ARE FOR NEW CONSTRUCTION. F: GLUING INTO EXISTING DIDWP_ c Ii IrU AC N.II TUC rACC nC r1 rr-IAIC rl n]Ac c C Txunt n n OC A LAIKELAa CURE TIMES WITH ONE 225 PSI (MAXIMUM) TEST STEP SOLVENT CEMENT PRESSURE (SEE NOTE 1) 'R' @ GREATER THAN 100 PSI E FINCHES AMBIENT TEMPERATURE DURING CURE PERIOD 60°F TO 120°F 40'F TO 59'F 0°F TO 39°F 0'-9' 1 HR, 4 HR, 48 HR, Y4' 1.5 HR, 4 HR, 48 HR, 134' 3 HR, 32 HR. 10 DAYS 125.4' 3 HR. 32 HR, 10 DAYS 12.3' 8 HR, 48 HR, SEE NOTE 2 L2Y2' 24 HR, 96 HR, SEE NOTE 2 5,0' 24 HR. 96 HR, SEE NOTE 2 p NOTE tTHESE CURE TMIES ARE FOR NEW CONSTRUCTION. F: GLUING INTO EXISTING DIDWP_ c Ii IrU AC N.II TUC rACC nC r1 rr-IAIC rl n]Ac c C Txunt n n OC A LAIKELAa ALL MATERIAL APPLICABLE TO THIS PROJECT WILL R MAX ANY DISTANCE S AX HANGER BE INDICATED WITH A (9/) (1/2 'S' MAX) OR CLAMP (TYP,) ALL PLASTIC PIPE 3/4 THROUGH 2Y2 SHALL BE UL LISTED OR FM APPROVED CPVC MANUFACTURED IN ACCORDANCE WITH ASTM F-442. ALL PLASTIC FITTINGS SHALL BE UL LISTED OR FM APPROVED CPVC MANUFACTURED IN ACCORDANCE WITH ASTM f438, ASTM F439 OR ASTM F1970. ALL CPVC PIPE AND FITTINGS SHALL BE ASSEMBLED USING 'ONE STEP' 500 CEMENT. UNHEATED ;) OR Qlf CPVC PIPE SHALL BE ALLOWED TO BE USED M ORDINARY HAZARD ROOMS OF 400 SQUARE FEET OR INSULATION ATTIC LESS OF OTHERWISE LIGHT HAZARD OCCUPANCIES (NFPA 13 SECTION 6.3.6.2 OR NFPA 13R SECTION (BY OTHERS) SPRINKLER TEE DROP SUPPORT SPACING WITH SPRINKLER DROP SUPPORT SPACING 5.2.2.3)' ONE RESTRAINT POINT - SEE TABLE I BELOW WITH TWO RESTRAINT POINTS - ❑ ALL 1- TO 2- THREADED BLACK STEEL PIPE SHALL BE UL LISTED/FM APPROVED AND MANUFACTURED 4 CEILING SEE TABLE 2 BELOW IN ACCORDANCE WITH ASTM A-135 OR A-795. ACCEPTABLE PIPE BRANDS ARE WHEATLAND 19-8" -'� R MAX 'MEGATHREAD', ALLIED 'DYNATHREAO', BULL MOOSE TUBE 'EDDYTHREAD' AND WELDED TUBE -BERKELEY j/ L FEET I STEADY -THREAD'. ALL PIPE SHALL BE (PVC COMPATIBLE (- HEATED HEATED L MAX ❑ ALL 1' TO 2- THREADED GALVANIZED PIPE WILL BE SCHEDULE 40 HOT DIPPED GALVANIZED UNIT UNIT MANUFACTURED IN ACCORDANCE WITH ASTM A-795 OR ASTM A-53. ❑ D ALL 1- TO 2- THREADED BLACK STEEL PIPE SHALL BE SCHEDULE 40 UL LISTED/FM APPROVED AND 2 ` ~ MANUFACTURED IN ACCORDANCE WITH ASTM A-795. ACCEPTABLE PIPE MANUFACTURERS ARE d - 0 329 L d INCHES WHEATLAND, ALLIED, BULL MOOSE TUBE AND WELDED TUBE -BERKELEY. ALL PIPE SHALL BE CPVC D ` ` COMPATIBLE. SPRINKLER 90' ELL DROP SUPPORT SPACING WITH MAXIMUM SUPPORT SPACING ❑ ALL 1Y4" TO :'GROOVED BLACK STEEL PIPE SHALL BELISTED/FM APPROVED AND MANUFACTURED ONE RESTRAINT POINT -SEE TABLE 1 BELOW IN ACCORDANCE WITH ASTM A795. ACCEPTABLE BRANDSS ARE BULL MOOSE 'EDDYFLOW', WHEATLAND SEE TABLE 3 BELOW 'MEGA -FLOW', ALLIED 'DYNA-FLOW' AND WELDED TUBE -BERKELEY 'STEADY -FLOW'. ALL PIPE SHALL BE PERMISSIBLE BENDING DEFLECTIONS SDR 135 (73'F) (ONE END RESTRAINED) 'R' @ GREATER THAN 100 PSI PIPE SIZE INCHES PIPE SIZE INCHES 0'-6' LENGTH OF RUN (L) IN LENGTH OF RUN (L) IN FEET 0'-9' 1% INCH 2' 5' 7' 10' 12' 15' 17' 20' Y4' 1.3' 7.8' 15,4' 31.3' 45.1' 70.5' 90.6' 125.4' 1' 1,0' 6,3' 12.3' 25.0' 36.0' 56.3' 72,3' 100.1' 3, 0.8' 5,0' 9.7' 19.8' 28,5' 44,6' 57,3' 79.3' 1V 0,7' 4,3' 8.5' 17,3' 24,9' 39.0' 50.1' 69.3' 2' 0,6' 3,5' 6.8' 13.9' 20.0' 31.2' 40.0' 55.4' 2)¢' 0.5' 2.9' 5.6' 11.4' 16.5' 25.8' 33.1' 45.8' 3' 0.4' 2.4' 4,6' 9.4' 13.5' 21,2' 27,2' 37,6' ALL MATERIAL APPLICABLE TO THIS PROJECT WILL R MAX ANY DISTANCE S AX HANGER BE INDICATED WITH A (9/) (1/2 'S' MAX) OR CLAMP (TYP,) ALL PLASTIC PIPE 3/4 THROUGH 2Y2 SHALL BE UL LISTED OR FM APPROVED CPVC MANUFACTURED IN ACCORDANCE WITH ASTM F-442. ALL PLASTIC FITTINGS SHALL BE UL LISTED OR FM APPROVED CPVC MANUFACTURED IN ACCORDANCE WITH ASTM f438, ASTM F439 OR ASTM F1970. ALL CPVC PIPE AND FITTINGS SHALL BE ASSEMBLED USING 'ONE STEP' 500 CEMENT. UNHEATED ;) OR Qlf CPVC PIPE SHALL BE ALLOWED TO BE USED M ORDINARY HAZARD ROOMS OF 400 SQUARE FEET OR INSULATION ATTIC LESS OF OTHERWISE LIGHT HAZARD OCCUPANCIES (NFPA 13 SECTION 6.3.6.2 OR NFPA 13R SECTION (BY OTHERS) SPRINKLER TEE DROP SUPPORT SPACING WITH SPRINKLER DROP SUPPORT SPACING 5.2.2.3)' ONE RESTRAINT POINT - SEE TABLE I BELOW WITH TWO RESTRAINT POINTS - ❑ ALL 1- TO 2- THREADED BLACK STEEL PIPE SHALL BE UL LISTED/FM APPROVED AND MANUFACTURED 4 CEILING SEE TABLE 2 BELOW IN ACCORDANCE WITH ASTM A-135 OR A-795. ACCEPTABLE PIPE BRANDS ARE WHEATLAND 19-8" -'� R MAX 'MEGATHREAD', ALLIED 'DYNATHREAO', BULL MOOSE TUBE 'EDDYTHREAD' AND WELDED TUBE -BERKELEY j/ L FEET I STEADY -THREAD'. ALL PIPE SHALL BE (PVC COMPATIBLE (- HEATED HEATED L MAX ❑ ALL 1' TO 2- THREADED GALVANIZED PIPE WILL BE SCHEDULE 40 HOT DIPPED GALVANIZED UNIT UNIT MANUFACTURED IN ACCORDANCE WITH ASTM A-795 OR ASTM A-53. ❑ D ALL 1- TO 2- THREADED BLACK STEEL PIPE SHALL BE SCHEDULE 40 UL LISTED/FM APPROVED AND 2 ` ~ MANUFACTURED IN ACCORDANCE WITH ASTM A-795. ACCEPTABLE PIPE MANUFACTURERS ARE d - 0 329 L d INCHES WHEATLAND, ALLIED, BULL MOOSE TUBE AND WELDED TUBE -BERKELEY. ALL PIPE SHALL BE CPVC D ` ` COMPATIBLE. SPRINKLER 90' ELL DROP SUPPORT SPACING WITH MAXIMUM SUPPORT SPACING ❑ ALL 1Y4" TO :'GROOVED BLACK STEEL PIPE SHALL BELISTED/FM APPROVED AND MANUFACTURED ONE RESTRAINT POINT -SEE TABLE 1 BELOW IN ACCORDANCE WITH ASTM A795. ACCEPTABLE BRANDSS ARE BULL MOOSE 'EDDYFLOW', WHEATLAND SEE TABLE 3 BELOW 'MEGA -FLOW', ALLIED 'DYNA-FLOW' AND WELDED TUBE -BERKELEY 'STEADY -FLOW'. ALL PIPE SHALL BE TABLE 1 - SPRINKLER SUPPORT SPACING DISTANCE WITH ONE RESTRAINT POINT PERMISSIBLE BENDING DEFLECTIONS SDR 135 (73'F) (BOTH ENDS RESTRAINED) 'R' @ LESS THAN 100 PSI 'R' @ GREATER THAN 100 PSI PIPE SIZE INCHES 0'-9' 0'-6' LENGTH OF RUN (L) IN FEET 0'-9' 1% INCH 2' 5' 7' 10' 12' 15' 17' 20' Y4' 0,3' 2.0' 3.8' 7.8' 11.3' 17.6' 22.6' 31.3' 1' 0,3' 1.6' 3.1' 6.3' 9.0' 14,1' 18,1' 25.0' lib' 0.2' 1.2' 2.4' 5.0' 1 7.1' 11.2' 14,3' 19.8' $8 0,2' Ll' 2,1' 4.3' 6.2' 9,7' 12.5' 17,3' 2' 0,1' 0.9' 1.7' 3,5' 5,0' 7,8' 10.0' 13,9' 2�' 0.1' 0.7' 1.4' 2.9' 4.1' 6,4' 8.3' 11,4' 3' 1 0,1' 0.6' 1 1.2' 2,4' 3,4' 1 5.3' 1 6,8' 9.4' TABLE 1 - SPRINKLER SUPPORT SPACING DISTANCE WITH ONE RESTRAINT POINT NOM. PIPE SIZE 'R' @ LESS THAN 100 PSI 'R' @ GREATER THAN 100 PSI Y4 INCH 0'-9' 0'-6' 1 INCH 1'-0' 0'-9' 1% INCH 1'-4' 1'-0' V2 INCH 21-0' 1'-0' >1321NCH 2'-0' 1'-0' TABLE 2 - SPRINKLER SUPPORT SPACING DISTANCE WITH TWO RESTRAINT POINTS NOM. PIPE SIZE 'S' @ LESS THAN 100 PSI 'S' @ GREATER THAN 100 PSI 3 INCH 4'-0' 3'-0' 1 INCH 5'-0' 4'-0' 134 INCH 6'-0' 5'-0' 132 INCH 7'-0' T-0' _>132 INCH 7'-0' 7'-0' (PVC COMPATIBLE. 2ND FLOOR 44r - ALL f/4- TO 4" GROOVED BLACK STEEL PIPE SHALL BE SCHEDULE 10, UL LISTED/FM APPROVED AND ❑ MANUFACTURED IN ACCORDANCE WITH ASTM A-795. ACCEPTABLE MANUFACTURERS ARE BULL MOOSE, WHEATLAND, ALLIED AND WELDED TUBE -BERKELEY. ALL PIPE SHALL BE CPVC COMPATIBLE. _ _ CEILING ❑ ALL GROOVED STEEL PIPE 6' AND LARGER SHALL BE UL LISTED/FM APPROVED SCHEDULE 10 AND 91-4e MANUFACTURED IN ACCORDANCE WITH ASTM A-135. HEATED HEATED ❑ ALL GROOVED STEEL PIPE IY4- AND LARGER SHALL BE SCHEDULE 10 HOT DIPPED GALVANIZED AND UNIT UNIT MANUFACTURED IN ACCORDANCE WITH ASTM A-795. ❑ ALL STEEL PIPE SHALL HAVE A CORROSION RESISTANCE RATIO (CRR) OF NOT LESS THAN 1.0 PER WAFS STANDARDS. ❑ ALL BLACK THREADED FITTINGS SHALL BE DUCTILE IRON CLASS 150 OR CLASS 300 ANSI 816.3, CAST IRON CLASS 125 OR CLASS 250 ANSI 816.4 OR MALLEABLE IRON CLASS 150 OR CLASS 300 ANSI 816.3. oF 24 HOLMu ALL UAL V AN14tU I HHLAUED FITTINGS I INbb SHALL BE MALLEABLE !HUN CLAbb rJU UH CLASS 300 ANSI - L FEET NOTE 21 FOR THESE SIZES, THE SOLVENT CEMENT CAN BE APPLIED AT TEMPERATURES BELOW 32T, HOWEVER, THE SPRINKLER SYSTEM TEMPERATURE MUST BE RAISED TO A TEMPERATURE OF 320E OR ABOVE AND ALLOWED TO CURE PER THE ABOVE RECOMMENDATIONS PRIOR TO PRESSURE TESTING, D d = 0,0823 �2 \ �\ d INCHES D \� TABLE 3 - MAXIMUM SUPPORT SPACING NOM, PIPE Y4 INCH 1 INCH 13'4 INCH 132 INCH 2 INCH 232 INCH 3 INCH SIZE 4 FT, 6 IN, TO LESS THAN 6 FT, 7 6 FT, TO LESS THAN 6 FT, 6 IN, 9 6 FT. 6 IN, TO LESS THAN 7 FT. 11 7 FT, AND GREATER SUPPORT 5'-6' 6'-0' 6'-6' 7'-0' 8'-0' 9'-0' 10'-0' SPACING 'L' TIME OF TEST 8:00 AM DESIGN AREA SF, PITOT READING 36 PSI TYP, 1 B16.3 WITH GALVANIZED COATING IN ACCORDANCE WITH ASTM A-153. 11 II IIILLL NNN 1 ST FLOOR ❑ ALL WELDED OUTLETS SHALL BE UL LISTED OR FM APPROVED AND MANUFACTURED IN ACCORDANCE WITH ANSI 816.11. ❑ GROOVED FITTINGS SHALL BE UL LISTED OR FM APPROVED AND MANUFACTURED IN ACCORDANCE WITH ASTM A-536 FOR DUCTILE IRON OR ASTM A-47 FOR MALLEABLE IRON. ❑ ALL GALVANIZED GROOVED FITTINGS SHALL BE UL LISTED OR FM APPROVED AND MANUFACTURED IN ACCORDANCE WITH ASTM A-536 FOR DUCTILE IRON OR ASTM A-47 FOR MALLEABLE IRON. GALVANIZED COATING SHALL BE IN ACCORDANCE WITH ASTM A-153. ❑ ALL GROOVED STEEL PIPE SHALL BE ROLL GROOVED PER PIPE MANUFACTURER REQUIREMENTS. TYPICAL CPVC CURE TIMES CPVC BENDING DEFLECTIONS TYPICAL CPVC HANGER/BRACE SPACING PIPE AND FITTINGS GENERAL NOTES TYPICAL RESIDENTIAL CROSS SECTION - 2 FLOOR SCALEi NONE SCALE, NONE SCALE, NONE SCALD NONE AYNE DYNEAYI�E AYIV� Automatio Fire Sprinklers, Inc. Automatic Fire Sprinklers, Inc. Automatic Fire Sprinklers, Inc. AuEassEis Rre **d&m iw SCALE, NONE Automatic Fire Sprinklers, Inc. 00415N t 00416N 00356N 00859N 00683N pile is. 11 CEILING #12 X ly' HARDENED CEILING STRAP MAY BE USED HEX HEAD CPN C SPRINKLER ALTERNATE USAGE DF TYPICAL CEILING IN THIS POSITION AS SELF -THREADING LIE (3V4TO 2) A FIG, 24 PIPE HANGER DIFFUSER A RESTRAINER ONLY SCREW TYP, R1'-0' TOLCO FIG, #22C VIEW 'A' " TYP, SOFFIT (CONSISTING OF {2} . (OBSTRUCTION) B TYPICAL PENDENT TOLCO FIG, 22 PIPE SPRINKLER CPVC SPRINKLER STRAPS) WOOD FRAMING B ��� TYPICAL LINE (�' TO 2') MEMBER .. o. PENDENT TYPICAL TYP SPRTNQ.ER • A T IC L SPRINKLER TElPERATw OBSTRUCTION ..... CLASSIFICATD]r VIEW 'A' %' ALTERNATE USAGE OF D A SEE DETAIL VIEW FIG, 24 PIPE HANGER v DETAILVIEW o WALL a A go�a a� A 2 (D - 8 IN.) + B (A > (D - 0,2M) + B) a �jo 00 TOLCO FIG, 22 WOOD FRAMING ' D S 30 IN. (0.8M) PIPE STRAP MEMBER #10 X 1 OR TOLCO FIG, 24 (SIZED TO PIPE) #12 X 13;' HARDENED PIPE HANGER (PVC SPRINKLER HEX HEAD #12 X 1Y4' HARDENED HEX LINE (Y4' TO 2') WOOD FRAMING SELF -THREADING SCREW HEAD SELF -THREADING (X2) DISTANCE FROM SPRINKLER TO SIDE OF OBSTRUCTION (A) MAXIMUM ALLOWABLE DISTANCE OF DEFLECTOR ABOVE BOTTOM OF OBSTRUCTION (IN.) (B) LESS THAN 1 FT, 6 IN, 0 1 FT, 6 IN TO LESS THAN 3 FT, 1 3 FT, TO LESS THAN 4 FT, 3 4 FT, TO LESS THAN 4 FT, 6 IN. 5 4 FT, 6 IN, TO LESS THAN 6 FT, 7 6 FT, TO LESS THAN 6 FT, 6 IN, 9 6 FT. 6 IN, TO LESS THAN 7 FT. 11 7 FT, AND GREATER 14 MEMBER HANGER #04F SCREW (X2) HANGER #04J NFPA 13R Er 13D RESIDENTIAL PENDENT NFPA 13R Er 13D RESIDENTIAL PENDENT TYPICAL RESIDENTIAL CEILING MOUNTED HOT AIR SPRINKLER CLEARANCE W/ SOFFIT FOR 3/4' TO e* CPVC PIPE HANGER #040 FOR 3/40 TO e" CPVC PPE FIG. e4 HANGER FOR 3/47 TO 2e CPV( PIPE SPRINKLER CLEARANCE W/ OBSTRUCTION DIFFUSER SPRINKLER MINIMUM CLEARANCES '`dk n®Ilnlr SCALEi NONE SCALE, NONE SCALE, NONE SCALE, NONE SCALE, NONE �./ SCALE, NONE AYI�E WYNE AYH . AYI�E �AYNE Automatic Fire Sprinklers. Inc. 00531N Autwratla �e So'�"' lin% 00251N Auboalatic R. Sp Wdw% 00250N Aubwa@tlO R' ka 00282N Automatic Fire Sprinklers. Inc. 00527N Automatic Fire Sprinklers, Inc. 00702N LOTS 139-146 IMPORTANT OWNER INFORMATION GRAPHICS EL,F7vLFNTS NOTE THIS DRAWING IS BASED ON THE OWNER'S ACCEPTANCE OF THE CURRENTLY ADOPTED FIRE SPRINKLER CONSTRUCTION DRAWINGS AND SHOP DRAWINGS MAY INCLUDE EDITION (EITHER STATE OR LOCAL) OF NFPA 25 AS THE APPLICABLE STANDARD FOR BACKGROUND DRAWINGS OR GRAPHICS BORROWED FROM THE ARCHITECTURAL, CIVSL, THE INSPECTION, TESTING AND MAINTENANCE OF WATER BASED. FIRE PROTECTION STRUCTURAL, OR MEP DRAWINGS. THESE REFERENCE BACKGROUND ELEMENTS ARE FOR GENERAL INFORMATION OR CONTEXT ONLY AND THE FIRE SPRINKLER ENGINEER DOES SYSTEMS, PER SECTION 4.1, THE RESPONSIBILITY FOR PROPERLY MAINTAINING A. NOT ACCEPT ANY RESPONSIBILITY FOR THESE ELEMENTS, THE FIRE SPRINKLER WATER BASED FIRE PROTECTION SYSTEM SHALL BE THAT OF THE OWNER. IF THE ENGINEER IS ONLY RESPONSIBLE FOR THOSE PORTIONS OF THE FIRE SPRINKLER BUILDING OWNER HAS NOT RECEIVED A COPY OF THIS PAMPHLET AND/OR IS NOT DRAWINGS DEPICTING FIRE SPRINKLER SCOPES OF WORK. REFER TO APPROVED FAMILIAR WITH THE OPERATION AND MAINTENANCE OF THIS SYSTEM, PLEASE CONTACT ARCHITECTURAL, STRUCTURAL, MEP OR CIVIL DRAWINGS FOR AUTHORITATIVE THE NEAREST OFFICE OF WAYNE AUTOMATIC FIRE SPRINKLERS, INC. EXPRESSIONS OF BACKGROUND INFORMATION THAT MAY BE UTILIZED IN FIRE SPRINKLER DRAWINGS OR DETAILS CPVC COMPATIBILITY NOTICE CPVC FIRE SPRINKLER PIPING SYSTEMS HAVE BEEN USED SUCCESSFULLY FOR MORE THAN 20 YEARS IN NEW CONSTRUCTION, RE -PIPE AND REPAIR, CPVC PRODUCTS ARE IDEALLY SUITED FOR THESE APPLICATIONS DUE TO THEIR OUTSTANDING CORROSION RESISTANCE. OCCASIONALLY, HOWEVER, CPVC CAN BE DAMAGED BY CONTACT WITH CHEMICALS FOUND IN SOME CONSTRUCTION MATERIALS (IE- SOME WIRES, FLUX, PETROLEUM BASED PRODUCTS, ETC.) AND ANCILLARY PRODUCTS SUCH AS THREAD SEALANTS, LEAK DETECTORS, FIRESTOPS, ETC. ANY PRODUCT THAT COMES IN CONTACT WITH CPVC SPRINKLER PIPE MUST BE EVALUATED IN ACCORDANCE WITH THE SYSTEM COMPATIBILITY PROGRAM AS FOUND AT WWW.SYSTEMCOMPATIBLE,COM COPYRIGHT ALL DOCUMENTS, INCLUDING ORIGINAL DRAWINGS, SPECIFICATIONS, FIELD NOTES, ESTIMATES AND DATA, INCLUDING COMPUTER PROGRAMS PURSUANT TO THIS PROJECT ARE AND WILL REMAIN THE PROPERTYOF WAYNE AUTOMATIC FIRE SPRINKLERS, INC. (WAFS) AS INSTRUMENTS OF SERVICE. THEY ARE NOT INTENDED, NOR REPRESENTED TO BE SUITABLE FOR RE -USE BY THE CLIENT, OR OTHERS, ON EXTENSION OF THIS PROJECT, OR FOR ANY OTHER PROJECT. ANY REUSE, OR ADAPTATION OF THE NFORMATION CONTAINED HEREIN, WITHOUT SPECIFIC WRITTEN PERMISSION FROM WAFS WILL BE AT THE CLIENTS SOLE RISK, WITHOUT LIABILITY, OR LEGAL EXPOSURE TO WAFS, AND WILL ENTITLE WAFS TO FURTHER COMPENSATION AT RATES TO BE AGREED ON BETWEEN WAFS AND THE CLIENT. THE CLIENT SHALL ALSO INDEMNIFY AND HOLD WAFS HARMLESS FROM ANY AND ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES, INCLUDING ATTORNEYS FEES RESULTING FROM ANY SUCH PERMISSIONS. WATER SUPPLY INFORMATION FIRE SPRINKLER DETAILS ACTUAL (AS REWD BY W FIRE PUMP I TAL A/& SYSTEM / DESn EEXTRAPOLATED SIZE, GPM a PSI TEM'ERATIIItE HAZARD COSS STATIC PRESSURE 66 PSI CITY OF SANFORD HYDRANT ELEV, CLASSMTO # OF SPRINKLERS IN DESIGN AREA RESIDUAL PRESSURE 21-0, SHEET I DATE OF TEST 09/06/16 MINIMUM DENSITY TYP, 1010 GPM R2'-0' TIME OF TEST 8:00 AM DESIGN AREA SF, PITOT READING 36 PSI TYP, 1 2'-0' I GPM REaD a By TYP, NOTE, SPRINKLERS MUST BE LOCATED OUTSIDE OF SHADED AREA MEMBER HANGER #04F SCREW (X2) HANGER #04J NFPA 13R Er 13D RESIDENTIAL PENDENT NFPA 13R Er 13D RESIDENTIAL PENDENT TYPICAL RESIDENTIAL CEILING MOUNTED HOT AIR SPRINKLER CLEARANCE W/ SOFFIT FOR 3/4' TO e* CPVC PIPE HANGER #040 FOR 3/40 TO e" CPVC PPE FIG. e4 HANGER FOR 3/47 TO 2e CPV( PIPE SPRINKLER CLEARANCE W/ OBSTRUCTION DIFFUSER SPRINKLER MINIMUM CLEARANCES '`dk n®Ilnlr SCALEi NONE SCALE, NONE SCALE, NONE SCALE, NONE SCALE, NONE �./ SCALE, NONE AYI�E WYNE AYH . AYI�E �AYNE Automatic Fire Sprinklers. Inc. 00531N Autwratla �e So'�"' lin% 00251N Auboalatic R. Sp Wdw% 00250N Aubwa@tlO R' ka 00282N Automatic Fire Sprinklers. Inc. 00527N Automatic Fire Sprinklers, Inc. 00702N LOTS 139-146 IMPORTANT OWNER INFORMATION GRAPHICS EL,F7vLFNTS NOTE THIS DRAWING IS BASED ON THE OWNER'S ACCEPTANCE OF THE CURRENTLY ADOPTED FIRE SPRINKLER CONSTRUCTION DRAWINGS AND SHOP DRAWINGS MAY INCLUDE EDITION (EITHER STATE OR LOCAL) OF NFPA 25 AS THE APPLICABLE STANDARD FOR BACKGROUND DRAWINGS OR GRAPHICS BORROWED FROM THE ARCHITECTURAL, CIVSL, THE INSPECTION, TESTING AND MAINTENANCE OF WATER BASED. FIRE PROTECTION STRUCTURAL, OR MEP DRAWINGS. THESE REFERENCE BACKGROUND ELEMENTS ARE FOR GENERAL INFORMATION OR CONTEXT ONLY AND THE FIRE SPRINKLER ENGINEER DOES SYSTEMS, PER SECTION 4.1, THE RESPONSIBILITY FOR PROPERLY MAINTAINING A. NOT ACCEPT ANY RESPONSIBILITY FOR THESE ELEMENTS, THE FIRE SPRINKLER WATER BASED FIRE PROTECTION SYSTEM SHALL BE THAT OF THE OWNER. IF THE ENGINEER IS ONLY RESPONSIBLE FOR THOSE PORTIONS OF THE FIRE SPRINKLER BUILDING OWNER HAS NOT RECEIVED A COPY OF THIS PAMPHLET AND/OR IS NOT DRAWINGS DEPICTING FIRE SPRINKLER SCOPES OF WORK. REFER TO APPROVED FAMILIAR WITH THE OPERATION AND MAINTENANCE OF THIS SYSTEM, PLEASE CONTACT ARCHITECTURAL, STRUCTURAL, MEP OR CIVIL DRAWINGS FOR AUTHORITATIVE THE NEAREST OFFICE OF WAYNE AUTOMATIC FIRE SPRINKLERS, INC. EXPRESSIONS OF BACKGROUND INFORMATION THAT MAY BE UTILIZED IN FIRE SPRINKLER DRAWINGS OR DETAILS CPVC COMPATIBILITY NOTICE CPVC FIRE SPRINKLER PIPING SYSTEMS HAVE BEEN USED SUCCESSFULLY FOR MORE THAN 20 YEARS IN NEW CONSTRUCTION, RE -PIPE AND REPAIR, CPVC PRODUCTS ARE IDEALLY SUITED FOR THESE APPLICATIONS DUE TO THEIR OUTSTANDING CORROSION RESISTANCE. OCCASIONALLY, HOWEVER, CPVC CAN BE DAMAGED BY CONTACT WITH CHEMICALS FOUND IN SOME CONSTRUCTION MATERIALS (IE- SOME WIRES, FLUX, PETROLEUM BASED PRODUCTS, ETC.) AND ANCILLARY PRODUCTS SUCH AS THREAD SEALANTS, LEAK DETECTORS, FIRESTOPS, ETC. ANY PRODUCT THAT COMES IN CONTACT WITH CPVC SPRINKLER PIPE MUST BE EVALUATED IN ACCORDANCE WITH THE SYSTEM COMPATIBILITY PROGRAM AS FOUND AT WWW.SYSTEMCOMPATIBLE,COM COPYRIGHT ALL DOCUMENTS, INCLUDING ORIGINAL DRAWINGS, SPECIFICATIONS, FIELD NOTES, ESTIMATES AND DATA, INCLUDING COMPUTER PROGRAMS PURSUANT TO THIS PROJECT ARE AND WILL REMAIN THE PROPERTYOF WAYNE AUTOMATIC FIRE SPRINKLERS, INC. (WAFS) AS INSTRUMENTS OF SERVICE. THEY ARE NOT INTENDED, NOR REPRESENTED TO BE SUITABLE FOR RE -USE BY THE CLIENT, OR OTHERS, ON EXTENSION OF THIS PROJECT, OR FOR ANY OTHER PROJECT. ANY REUSE, OR ADAPTATION OF THE NFORMATION CONTAINED HEREIN, WITHOUT SPECIFIC WRITTEN PERMISSION FROM WAFS WILL BE AT THE CLIENTS SOLE RISK, WITHOUT LIABILITY, OR LEGAL EXPOSURE TO WAFS, AND WILL ENTITLE WAFS TO FURTHER COMPENSATION AT RATES TO BE AGREED ON BETWEEN WAFS AND THE CLIENT. THE CLIENT SHALL ALSO INDEMNIFY AND HOLD WAFS HARMLESS FROM ANY AND ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES, INCLUDING ATTORNEYS FEES RESULTING FROM ANY SUCH PERMISSIONS. WATER SUPPLY INFORMATION FIRE SPRINKLER DETAILS ACTUAL (AS REWD BY W FIRE PUMP I TAL A/& SYSTEM / DESn EEXTRAPOLATED SIZE, GPM a PSI DATE, HAZARD COSS STATIC PRESSURE 66 PSI CITY OF SANFORD HYDRANT ELEV, 2' # OF SPRINKLERS IN DESIGN AREA RESIDUAL PRESSURE 56 PSI SHEET I DATE OF TEST 09/06/16 MINIMUM DENSITY FLOW IN GPM 1010 GPM TIME OF TEST 8:00 AM DESIGN AREA SF, PITOT READING 36 PSI NUMBER OF PORTS FLOWED 1 PSI READ a BW I GPM REaD a By TEST PROVIDED BY I WAYNE AUTOMATIC FIRE SPRINKLERS, INC, I PSI REWD E NIYD GPM REWD SPRINKLER HYDRANT HOSE LOCATION OR TEST HYDRANT LOCATED ON WHITE CEDAR ROAD INSIDE�I7SD>E NUMBER DOMESTIC DEMAND DESIGN CRITERIA SPRINKLERS SPACING SYMBOL I MAXIMUM I MINIMUM 1COMMENTS r -QUANTITY -i SPRINKLERS IST 12ND I I I SIN ISIZE1 K ITEMPI MODEL TOTAL PER FLOOR TOTAL PER UNIT TOTAL THIS SHEET DATE I SUBMIT'TAIS BY 09/13/16 1 QA REVIEW MPF N0. DATE REVISIONS BY r �w w Automatic Fire Sprinklers, Inc. MAIN OFFICE - ORLANDO, FLORIDA 222 CAPITOL COURT OCOEE. FLORIDA 34761 PHONE: (407) 658-3030 FAX (407) 656-8026 JACKSO WLM FL TAMPA, FL POMPANO BEACH, FL 11326 DISTRIBUTION AVE WEST 32M CHERRY PALM DRIVE 3121 NW 18TH TERRACE JACKSONVILLE FL 32258-2745 TAMPA, FL 33SM -6337 POMPANO BEACH. FL 33064-1408 PHONE (904) 268-3030 PHONE: (813) 630-0303 PHONE (954) 917-3030 FAX (904) 268-0724 FAX: (813) 830-0312 FAX: (954) 817-8424 FT. MYERS. FL CONCORD, NC STATE LICENSES: 4883 LAREDO AVE 4370 MOTORSPORT DRIVE NC SPRNaFR: 29745 FT. MYERS, FL 33905-4924 CONCORD. NC M027-8977 NC ALARA: 29222 SP LV PHONE (239) 433-3030 PHONE: (704) 782-3032 SC SPRI IKLE - 1118 FAX (239) 433-3263 FAX: (704) 78S-6838 SC ALARA: 3385 THORNEBROOKE TOWNHOMES WHITE CEDAR ROAD _ SANF RD. FL 32771 TAYLOR MORRISON HOMES 151 SOUTHHALL LANE, SUITE 200 MAITLAND, FL 32751 SHEET TITLEn FIRE SPRINKLER DETAILS DRAWN BYn MICKEY FERGUSON I TAL A/& 144 DATE, SEPTEMBER 12, 2016 AIL► CITY OF SANFORD CWTRACr I 84194 CENTER OF TILE JOB? ❑ YES W NO I CENTER ON FIXTURES JOB? ❑ YES &ZNO SHEET I FP D n 1 CONSTRUCTION TYPE, V -B OCCUPANCY, R-3 ►;Mo SIO) 2' 1' 0 4' 8' 1 1 1 1 1 n F7711 I in SCALE 1/4' = V 1ST FLOOR A e _--I--- — — — — — — — — — — — — — ----- i I I I ( I I i 1 1 BIRCH UNIT FIRE PROTECTION PLAN (1,832 SD. FT.) IMPORTANT OWNER INFORMATION CYRAPHICS ELEMENTS NOTE FIRE SPRINKLER CONSTRUCTION DRAWINGS AND SHOP DRAWINGS MAY INCLUDE THIS DRAWIN S BASE➢ N H OWNER'S ACCEPTANCE F THE CURRENTLY ADOPTED IES E G1 O THE E CE EO EDITION (EITHER STATE OR LOCAL) OF NFPA 25 AS THE APPLICABLE STANDARD FOR BACKGROUND DRAWINGS WI GRAPHICS BORROWED FROM THE ARCHITECTURAL, CIVIL, THE INSPECTION, TESTING AND MAINTENANCE OF WATER BASED FIRE PROTECTION STRUCTURAL, OR MEP DRAWINGS, THESE REFERENCE BACKGROUND ELEMENTS ARE FOR NERAL INFORMATION R CONTEXT ONLY AND THE FIRE SPRINKLER ENGINEER DOES GE I ❑ SYSTEMS, PER SECTION 4,1 THE RESPONSIBILITY FOR PROPERLY MAINTAINING A NOT ACCEPT ANY RESPONSIBILITY FOR THESE ELEMENTS. THE FIRE SPRINKLER ❑ CC I 0 WATER BASED FIRE PROTECTION SYSTEM SHALL BE THAT OF THE OWNER, IF THE ENGINEER IS ONLY RESPONSIBLE FOR THOSE PORTIONS OF THE FIRE SPRINKLER BUILDING OWNER HAS NOT RECEIVED A COPY OF THIS PAMPHLET AND/OR IS NOT DRAWINGS DEPICTING FIRE SPRINKLER SCOPES OF WORK. REFER TO APPROVED FAMILIAR WITH THE OPERATION AND MAINTENANCE OF THIS SYSTEM, PLEASE CONTACT ARCHITECTURAL, STRUCTURAL, MEP OR CIVIL DRAWINGS FOR AUTHORITATIVE THE NEAREST OFFICE OF WAYNE AUTOMATIC FIRE SPRINKLERS, INC, EXPRESSIONS OF BACKGROUND INFORMATION THAT MAY BE UTILIZED IN FIRE SPRINKLER DRAWINGS OR .DETAILS CPVC COMPATIBILITY NOTICE CPVC FIRE SPRINKLER PIPING SYSTEMS HAVE BEEN USED SUCCESSFULLY FOR MORE THAN 20 YEARS IN NEW CONSTRUCTION, RE -PIPE AND REPAIR. CPVC PRODUCTS ARE IDEALLY SUITED FOR THESE APPLICATIONS DUE TO THEIR OUTSTANDING CORROSION RESISTANCE, OCCASIONALLY, HOWEVER, CPVC CAN BE DAMAGED BY CONTACT WITH CHEMICALS FOUND IN SOME CONSTRUCTION MATERIALS (IES SOME WIRES, FLUX, PETROLEUM BASED PRODUCTS, ETC.) AND ANCILLARY PRODUCTS SUCH AS THREAD SEALANTS, LEAK DETECTORS, FIRESTOPS, ETC. ANY PRODUCT THAT COMES IN CONTACT WITH CPVC SPRINKLER PIPE MUST BE EVALUATED IN ACCORDANCE WITH THE SYSTEM COMPATIBILITY PROGRAM AS FOUND AT WWW.SYSTEMCOMPATIBLE.COM COPYRIGHT ALL DOCUMENTS, INCLUDING ORIGINAL DRAWINGS, SPECIFICATIONS, FIELD NOTES, ESTIMATES AND DATA, INCLUDING COMPUTER PROGRAMS PURSUANT TO THIS PROJECT ARE AND WILL REMAIN THE PROPERTYOF WAYNE AUTOMATIC FIRE SPRINKLERS, INC. (WAFS) AS INSTRUMENTS OF SERVICE. THEY ARE NOT INTENDED, NOR REPRESENTED TO BE SUITABLE FOR RE -USE BY THE CLIENT, OR OTHERS, ON EXTENSION OF THIS PROJECT, OR FOR ANY OTHER PROJECT. ANY REUSE, OR ADAPTATION OF THE NFORMATION CONTAINED HEREIN, WITHOUT SPECIFIC WRITTEN PERMISSION FROM WAFS WILL BE AT THE CLIENTS SOLE RISK, WITHOUT LIABILITY, OR LEGAL EXPOSURE TO WAFS, AND WILL ENTITLE WAFS TO FURTHER COMPENSATION AT RATES TO BE AGREED ON BETWEEN WAFS AND THE CLIENT. THE CLIENT SHALL ALSO INDEMNIFY AND HOLD WAFS HARMLESS FROM ANY AND ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES, INCLUDING ATTORNEYS FEES RESULTING FROM ANY SUCH PERMISSIONS. WATER SUPPLY INFORMATION SYSTEN i AREA It ACTUAL EXTRAPOLATTEED (AS REQ'D BY AIU FIRE PUMP ® SIZE, GPM a PSI NEPA 13D 2 i STATIC PRESSURE 66 PSI WITRADT 4 HYDRANT ELEV, 2' RESIDUAL PRESSURE 56 PSI 45 DATE OF TEST 09/06/16 FLOW IN GPM 1010 GPM TIME OF TEST 800 AM PITOT READING 36 PSI NUMBER OF PORTS FLOWED 1 TEST PROVIDED BY WAYNE AUTOMATIC FIRE SPRINKLERS, INC. HYDRANT LOCATION OR NUMBER TEST HYDRANT LOCATED ON WHITE CEDAR ROAD DESIGN CRITERIA SYSTEN i AREA It B-1 B-2 COMMENTS ® HazaRD CLASS I OF SPRINKLERS IN DESIGN AREA NEPA 13D 2 NEPA 13D 2 Redwood WITRADT 4 MINIMUM DENSITY .05 .05 146 45 DESIGN AREA SF. 2 SPRKS 2 SPRKS PSI REQ'D E DD 27,0 44.3 WN REWD 11111 26.3 40,9 PSI REOT a HYD 37.3 57.8 W1 REn I HYD 31.3 45.9 ELEVATO E HIGHEST SIVINKLER 19'-8' 19'-8' INSE SIIDEMITSIDE N/A N/A DaMESTIC DEMAND 5 GPM 5 GPM J.rA11V h.KJ JY ILL AU11NU SYMBOL MAXIMUM MINIMUM COMMENTS ® 1616' U.N.O. 8' BETWEEN SPRINKLERS DEFl.ECTOR 8'-0' MAX SPACING OFF WALL U.N.O. TO BE INSTALLED 1"4 BELOW COUNG Redwood WITRADT 4 Redwood Redw )od Willow 146 45 un, 4 141J140 6' 120VAC BELL W/WEATHERPROOF BACK BOX LOCATE ON OUTSIDE WALL OF BUILDING (WIRED BY OTHERS) a,.r 3' X 3' X V CPVC REDUCING TEE----: 1$' x a' x V CPVC REDUCING TEE W/ V x V CPVC SPIG ADAPTER GALV. PLUG AND 300 PSI WATER GAUGE & 3 -WAY VALVE 116'xlVA' CPVC REDUCING TEE___5 W/POTTER GLUE IN FLOW SWITCH (WIRED BY OTHERS) 3' CPVC CHECK VALVE --fir IV COUP & $'XW" CPVC BUSHING OVERHEAD PERMIT T( START AT 1'-0' A.F.F. TO SPRINKLER SYSTEM SEE UNIT PLANS FOR CONTINUATION Ik' SPLIT RING HANGER /1-3/8' A.T.R. & HILTI DROP-IN ANCHOR DYNAFLOW SLEEVE ----- FROM SUPPLY 1 1/2' BY OTHERS CPVC Fire Sprinklers, Inc. TYPICAL SPRINKLER 36' MINIMUM NO SPARE SPRINKLERS REQUIRED PER NFPA 13D V CPVC BALL VALVE V CPVC 90' OUT WALL /— TO 16'x)' SPIGOT ADAPTER / & SAWN HEAD PIPE ROTATED FOR CLARITY TYPICAL EXPOSED CPVC FIRE SPRINKLER RISER SCALE, NONE TYPICAL LIGHT Sf FIXTURE OIN ROOMS/COMPARTMENTS 400 CU. FT. OR LESS, SPRINKLERS MAY BE PLACED REGARDLESS OF LOCATION OF OBSTRUCTIONS. NFPA 13R G 13D SPGIINICLrA CI_FAAAmrr W/ 1 I11.14T FIYTIIRF Firs Sprinklers, Inc. i—QUANTITY-1 SPRINl1LL' RAJ SYMB IST 2ND 3RD 4TH SIN SIZE K TEMP MODEL • 8 11 R3516 4,9 155• RELIABLE MODEL FI RES, PEND. WHITE W/ RECESSED ESCS. RELIABLE MODEL F1 RES, PEND. ® 1 0 83516 1" 4,9 175 yHM Wi RFcm n m. 9 Jill I TOTAL PER FLOOR 20 TOTAL PER UNIT 40 TOTAL THIS SHEET -NUMLL, IVLINr 00504N DATE I SUBMITTALS 09/13/16 1 QA REVIEW • DESIGN AND INSTALLATION TO BE IN ACCORDANCE WITH 2010 EDITION OF NFPA 13D. • DESIGN AND INSTALLATION TO BE IN ACCORDANCE WITH ALL APPLICABLE LOCAL AND STATE CODES. • ALL PIPE AND FITTINGS USED ON THIS PROJECT TO BE IN ACCORDANCE WITH APPLICABLE CODES AND WAFS STANDARDS. SEE PIPE AND FITTINGS GENERAL NOTES (WAFS DETAIL #00593N). • ALL HANGERS SHALL BE DESIGNED AND INSTALLED IN ACCORDANCE ,WITH NFPA 13D AND THEIR LISTING. • ALL PENETRATIONS THROUGH RATED BUILDING ASSEMBLIES SHALL BE SEALED WITH FIRE CAULK IN ACCORDANCE WITH DETAILS PROVIDED. WAFS POLICY IS TO USE HILTI FS ONE OR STI LCI. • UNDERGROUND MAINS AND LEAD-INS SHALL BE FLUSHED AND SIGNED TEST CERTIFICATES PROVIDED BEFORE A CONNECTION IS MADE TO THE SPRINKLER SYSTEM. • WHEN SYSTEM IS FED USING PLUMBING SERVICE, PIPING SHALL STILL BE FLUSHED PRIOR TO CONNECTING THE SPRINKLER SYSTEM. • ALL PIPING SHALL BE INSPECTED AND APPROVED BY PROPER AUTHORITIES PRIOR TO COVERING WITH DRYWALL. COPIES OF SIGNED TEST CERTIFICATES ARE TO BE FORWARDED TO THE PROPER RECIPIENTS. • ALL SYSTEMS SHALL BE TESTED AT 200 PSI FOR 2 HOURS PER WAFS STANDARDS. • ALL SOFFITS REQUIRED TO CONCEAL SPRINKLER PIPING ARE BY OTHERS. • ALL WIRING OF DEVICES IF PROVIDED (FLOW SWITCHES, TAMPER SWITCHES, ETC) IS BY OTHERS. • VALVES SHALL NOT BE REQUIRED TO BE MONITORED PER FLORIDA BUILDING CODE 903.4 (1). • LOCAL WATERFLOW ALARMS SHALL BE PROVIDED ON ALL SPRINKLER SYSTEMS IN HOMES NOT EQUIPPED WITH SMOKE ALARMS OR SMOKE DETECTORS IN ACCORDANCE WITH NFPA 72, NATIONAL FIRE ALARM CODE. • CONNECTION OF SPRINKLER DEVICES TO THE BUILDING ALARM OR MONITORING SYSTEM, IF PROVIDED, IS BY OTHERS. • ALL PAINTING OF PIPE AS REQUIRED IS BY OTHERS. • ALL INSULATION REQUIRED FOR FREEZE PROTECTION OF SPRINKLER PIPING IS BY OTHERS. • HEATING OF ROOMS TO MAINTAIN TEMPERATURES OF 40 DEGREES OR GREATER IS BY OTHERS. • SPRINKLERS SHALL NOT BE INSTALLED PRIOR TO THE FITTINGS BEING CEMENTED IN PLACE. • ALL SPRINKLERS IN DWELLING UNITS SHALL BE UL LISTED OR FM APPROVED RESIDENTIAL SPRINKLERS. • SPARE SPRINKLERS WILL NOT BE PROVIDED AS THEY ARE NOT REQUIRED BY NFPA 13D. • REFER TO SPACING NOTES ON PLANS FOR MAXIMUM CALCULATED SPACING ALLOWANCES. • SPRINKLERS SHALL BE INSTALLED IN ALL AREAS EXCEPT AS FOLLOWS: o BATHROOMS WHERE THE AREA DOES NOT EXCEED 55 SQ FT. o CLOTHES CLOSETS, LINEN CLOSETS AND PANTRIES WITHIN THE DWELLING UNITS THAT DO NOT EXCEED 24 SQUARE FEET, THE LEAST DIMENSION DOES NOT EXCEED 3 FEET, AND THE WALLS AND CEILINGS ARE SURFACED WITH NONCOMBUSTIBLE OR LIMITED -COMBUSTIBLE MATERIALS AS DEFINED BY NFPA 220, STANDARD ON TYPES OF BUILDING CONSTRUCTION. o ANY GARAGES, OPEN ATTACHED PORCHES, CARPORTS AND SIMILAR STRUCTURES. o ATTICS, PENTHOUSE EQUIPMENT ROOMS, ELEVATOR MACHINE ROOMS, CONCEALED SPACES DEDICATED EXCLUSIVELY TO AND CONTAINING ONLY DWELLING UNIT VENTILAION EQUIPMENT, FLOOR/CEILING SPACES, ELEVATOR SHAFTS, CRAWL SPACES, AND OTHER CONCEALED SPACES THAT ARE NOT USED OR INTENDED FOR LIVING PURPOSES AND DO NOT CONTAIN FUEL -FIRED EQUIPMENT. o COVERED UNHEATED PROJECTIONS OF THE BUILDING AT ENTRANCES/EXITS AS LONG AS THERE IS ANOTHER MEANS OF EGRESS FROM THE DWELLING UNIT. o SPRINKLERS SHALL NOT BE REQUIRED FOR CEILING POCKETS THAT MEET THE FOLLOWING CONDITIONS: 1. THE TOTAL VOLUME OF UNPROTECTED CEILING POCKET DOES NOT EXCEED 100 CU. FT. E. THE ENTIRE FLOOR UNDER THE UNPROTECTED CEILING POCKET IS PROTECTED BY THE SPRINKLERS AT THE LOWER CEILING ELEVATION. 3. EACH UNPROTECTED CEILING POCKET IS SEPARATED FROM ANY ADJACENT UNPROTECTED CEILING POCKET BY A MINIMUM OF 10 FT. HORIZONTAL DISTANCE. 4. THE INTERIOR FINISH OF THE UNPROTECTED CEILING POCKET IS NONCOMBUSTIBLE OR LIMITED -COMBUSTIBLE MATERIAL. 5. SKYLIGHTS NOT EXCEEDING 32 SQ. FT, SHALL BE PERMITTED TO HAVE A PLASTIC COVER. • WAFS TO PROVIDE ALL REQUIRED SIGNAGE PER NFPA 13D INCLUDING BUT NOT LIMITED TO VALVES, HYDRAULIC PLACARDS, AND INSPECTION TAGS AS REQUIRED BY FS 633. • DEVICES THAT RESTRICT THE FLOW OR DECREASE THE PRESSURE OR AUTOMATICALLY SHUT OFF THE WATER TO THE SPRINKLER SYSTEM, SUCH AS WATER SOFTENERS, FILTRATION SYSTEMS, AND AUTOMATIC SHUTOFF VALVES, SHALL NOT BE ADDED TO THIS SYSTEM WITHOUT A REVIEW OF THE FIRE SPRINKLER SYSTEM BY A FIRE PROTECTION SPECIALIST. Fie ftd&brs, ho, 'L -'L"" inn (ANY MODEL IS ACCEPTABLE PROVIDED PLAN VIEW OF BLADES IS 50% OPEN) NFPA 13R & 13D �® SPRINKLER CLEARANCE W/ CEILING FAN E SCALE, NONE Pre Sprinklers, Inc. 00505N NFPA 13D 2010 GENERAL NOTES SCALEI NONE 00678N W R RIIIR MICKEY FERGUSON IMAL Aro 144 W Willow Redwood Redwood WITRADT 4 Redwood Redw )od Willow 146 45 un, 4 141J140 BY MPF NO. I DATE I FMIONS BY 1A1 x Ix LOTS 139-146 i THURNEB ROOKE TOW NHOMES WHITE CEDAR ROAD SANFORD. FL 32771 vv Vil,z: LI; i It Automatic Fire Sprinklers, Inc. MAIN OFFICE — ORLANDO, FLORIDA 222 CAPITOL COURT OCOEE. FLORIDA 34761 PHONE: (407) 656-3030 FAX: (407) 656-8026 JACKSONVLM FL TAWPA. FII. POMPANO BEACH, FL 11326 DISTRIBUTION AVE WEST 3226 CHERRY PALM DRIVE 3121 NW ISTH TERRACE JACKSONVILLE. FL 32258-2745 TAMPA, FL 33619-8337 POMPANO BEACH, FL 33084-1408 PHONE: (904) PBS -30M PHONE (813) 630-0303 PHONE: (954) 917-3030 FAX: (904) 268-0724 FAX: (813) 830-0312 FAX: (954) 917-9424 FT. WIPERS. FL CONCORD. NC STATE LICENSES: 4883 LAREDO AVE. 4370 MOTORSPORT DRIVE NC SPRBJ(LER: P-9745 FT. MYERS. FL 33905-4924 CONCORD. NC 28027-8977 NC ALARA: 28222 SP LV PHONE: (239) 433-3030 PHONE: (704) 782-3032 SC SPRINKLER 1116 FAX: (239) 433-3283 FAX: (704) 795-6838 SC ALARM: 3385 TAYLOR MORRISON HOMES 151 SOUTHHALL LANE, SUITE 200 MAITLAND, FL 32751 SHEET TITLE, BIRCH UNIT FIRE SPRINKLER LAYOUT DRAWN DY. MICKEY FERGUSON IMAL Aro 144 DATE. SEPTEMBER 12, 2016 A" CITY OF SANFORD WITRADT 4 84194 CENTER OF TILE JOB? ❑ YES JZN13 I CENTER EIN FIXTURES JOB? Q YES LZN13 SHEET # FPB, � CONSTRUCTION TYPE, V_IA OCCUPANCY R3 C Irr Ln Ln r-1 '-1 0 N `\ m rn Fr DESIGN AREA #R-1 IST FLOOR UNIT R FAMILY ROOM COMPARTMENT DESIGN PER NSA 130, 2010 EDITION. SECTION 8.1.2 Rl 20' X 20' SPACING 20,0 GPM @ 16.7 PSI R2 20' X 20' SPACING ���/ffALY 20,0 GPM @ 16,7 PSI y�/E 00853N Autu..te ,. M. 2' 1' 0 4' 8' 1177 SCALE 1/4' = 1' —� Lanai — — �— — Storage I I No A/S No A/S ® I o RI A I r� 1 R1T OZ' L r 2... r� � LJ • FIRE SPRINKLER CONSTRUCTION BACKGROUND DRAWINGS OR GRAPHICS BORROWED FROM THE ARCHITECTURAL, CIVIL, ® O i �00 Family Rood NFPA 13D 9'-4' C(g. DROUGHT OR FIRE PUMP # DF SPRINKLERS IN DESIGN AREA GENERAL INFORMATION OR CONTEXT ONLY AND THE FIRE SPRINKLER ENGINEER DOES NOT ACCEPT ANY RESPONSIBILITY FOR THESE ELEMENTS. THE FIRE SPRINKLER Lr Lr� EXTRAPOLATED MMK M DENSITY ,05 lie � V ENGINEER IS ONLY RESPONSIBLE FOR THOSE PORTIONS OF THE FIRE SPRINKLER .7 Ftt 2 SPRKS ] =A / o.. SIZE, GPM a PSI DRAWINGS DEPICTING FIRE SPRINKLER SCOPES OF WORK, REFER TO APPROVED ARCHITECTURAL, STRUCTURAL, MEP OR CIVIL DRAWINGS FOR AUTHORITATIVE - CD Caf e .'�. 9'-4' Clg. © 20 ® azo _ # t RA Z� _ 20 IrLsiollil, I Will I PIP Pa ntr,yy 14,7 Sq`rFt 9'-4' U9. Garage No A/S 9'-4' Mg. �M w -\— — — — — — — ---------- CL IMPORTANT OWNER INFORMATION THISDRAWING IS BASED ON THE OWNER'S ACCEPTANCE OF THE CURRENTLY ADOPTED EDITION (EITHER STATE OR LOCAL) OF NFPA 25 AS THE APPLICABLE STANDARD FOR THE INSPECTION, TESTING AND MAINTENANCE OF WATER BASED FIRE PROTECTION SYSTEMS, PER SECTION 4.1, THE RESPONSIBILITY FOR PROPERLY MAINTAINING A WATER BASED FIRE PROTECTION SYSTEM SHALL BE THAT OF THE OWNER. IF THE BUILDING OWNER HAS NOT RECEIVED A COPY OF THIS PAMPHLET AND/OR IS NOT FAMILIAR WITH THE OPERATION AND MAINTENANCE OF THIS SYSTEM, PLEASE CONTACT THE NEAREST OFFICE OF WAYNE AUTOMATIC FIRE SPRINKLERS, INC CPVC COMPATIBILITY NOTICE CPVC FIRE SPRINKLER PIPING SYSTEMS HAVE BEEN USED SUCCESSFULLY FOR MORE 1 THAN 20 YEARS IN NEW CONSTRUCTION, RE -PIPE AND REPAIR. CPVC PRODUCTS ARE IDEALLY SUITED FOR THESE APPLICATIONS DUE TO THEIR OUTSTANDING CORROSION RESISTANCE. OCCASIONALLY, HOWEVER, CPVC CAN BE DAMAGED BY CONTACT WITH CHEMICALS FOUND IN SOME CONSTRUCTION MATERIALS (IE- SOME WIRES, FLUX, PETROLEUM BASED PRODUCTS, ETC.) AND ANCILLARY PRODUCTS SUCH AS THREAD SEALANTS, LEAK DETECTORS, FIRESTOPS, ETC, ANY PRODUCT THAT COMES IN CONTACT WITH CPVC SPRINKLER PIPE MUST BE EVALUATED IN ACCORDANCE WITH THE SYSTEM COMPATIBILITY PROGRAM AS FOUND AT WWW,SYSTEMCOMPATIBLE.COM — COPYRIGHT ALL DOCUMENTS, INCLUDING ORIGINAL DRAWINGS, SPECIFICATIONS, FIELD NOTES, ESTIMATES AND DATA, INCLUDING COMPUTER PROGRAMS PURSUANT TO THIS PROJECT ARE AND WILL REMAIN THE PROPERTYOF WAYNE AUTOMATIC FIRE SPRINKLERS, INC. (WAFS) AS INSTRUMENTS OF SERVICE. THEY ARE NOT INTENDED, NOR REPRESENTED TO BE SUITABLE FOR RE -USE BY THE CLIENT, OR OTHERS, ON EXTENSION OF THIS PROJECT, OR FOR ANY OTHER PROJECT. ANY REUSE, OR ADAPTATION OF THE INFORMATION CONTAINED HEREIN, WITHOUT SPECIFIC WRITTEN PERMISSION FROM WAFS WILL BE AT THE CLIENTS SOLE RISK, WITHOUT LIABILITY, OR LEGAL EXPOSURE TO WAFS, AND WILL ENTITLE WAFS TO FURTHER COMPENSATION AT RATES TO BE AGREED ON BETWEEN WAFS AND THE CLIENT, THE CLIENT SHALL ALSO INDEMNIFY AND HOLD WAFS HARMLESS FROM ANY AND ALL CLAIMS, DAMAGES, LOSSES AND FYPCNQCC TNrl IMTNn ATTnRNCVS (CCC. RFSIII TTNG FRnM ANY SUCH PFRMTSTIWN . 84' Lintel Coats No A/S II L_�'/ r PO i�rL� 9 -4 Clg. Porch No A/S 1ST FLOOR 2ND FLOOR REDWOOD UNIT FIRE PROTECTION PLAN (1,943 SQ. FT.) GRAPHICS ELEMENTS NOTE DRAWINGS AND SHOP DRAWINGS MAY INCLUDE WATER SUPPLY INFORMATION FIRE SPRINKLER CONSTRUCTION BACKGROUND DRAWINGS OR GRAPHICS BORROWED FROM THE ARCHITECTURAL, CIVIL, COMMENTS ® 1616' U.N.O. STRUCTURAL, OR MEP DRAWINGS. THESE REFERENCE BACKGROUND ELEMENTS ARE FOR NFPA 13D Birch DROUGHT OR FIRE PUMP # DF SPRINKLERS IN DESIGN AREA GENERAL INFORMATION OR CONTEXT ONLY AND THE FIRE SPRINKLER ENGINEER DOES NOT ACCEPT ANY RESPONSIBILITY FOR THESE ELEMENTS. THE FIRE SPRINKLER 143 i ACTUAL EXTRAPOLATED MMK M DENSITY ,05 ENGINEER IS ONLY RESPONSIBLE FOR THOSE PORTIONS OF THE FIRE SPRINKLER DESIGN AREA SF, 2 SPRKS (ASREQ'D BY W SIZE, GPM a PSI DRAWINGS DEPICTING FIRE SPRINKLER SCOPES OF WORK, REFER TO APPROVED ARCHITECTURAL, STRUCTURAL, MEP OR CIVIL DRAWINGS FOR AUTHORITATIVE 39.6 GPM REO'D a DR EXPRESSIONS OF BACKGROUND INFORMATION THAT MAY BE UTILIZED IN FIRE STATIC PRESSURE 66 PSI HYDRANT ELEV, 2' SPRINKLER DRAWINGS OR DETAILS GIN REn a HYD 47.1 --- - RESIDUAL PRESSUR 56 PSI 9'-4' DATE OF TEST 09/06/16 HOSE EAUTSDIE FLOW IN GPM 1010 GPM TIME OF TEST 8100 AM 5 GPM PTiOT READING 36 PSI NUMBER OF PORTS FLOWED 1 TEST PROVIDED BY I WAYNE AUTOMATIC FIRE SPRINKLERS, INC. HYDRANT LOCATION DR TEST HYDRANT LOCATEDON WHITE CEDAR ROAD NUMBER I DESIGN CRITERIA SYSTEM / DESIGN AREA # R-1 COMMENTS ® 1616' U.N.O. HAZARD CLASS NFPA 13D Birch Willow # DF SPRINKLERS IN DESIGN AREA 2 143 i 142 MMK M DENSITY ,05 DESIGN AREA SF, 2 SPRKS PSI READ a N 39.6 GPM REO'D a DR 42.1 PSI RECD a HYD 572 GIN REn a HYD 47.1 ELEVATION a HIGHEST SPRINIUR 9'-4' HOSE EAUTSDIE N/A DWSTIC DEMAND 5 GPM SPRINKLERS SPACING SYMBOL MAXIMUM MINIMUM COMMENTS ® 1616' U.N.O. 8' BETWEEN SPRINKLERS a-0' MAX SPACING OFF WALL U.N.O. DERICTOR TO BE INSTALLED 1'4 BELOW CEILING Birch Willow 1146 143 i 142 139 TO SPRINKLER SYSTEM —SEE UNIT PLANS FOR CONTINUATION 6' 120VAC BELL W/WEATHERPROOF BACK BOX LOCATE ON OUTSIDE WALL OF \WOOD FLOOR TRUSS BUILDING (WIRED BY OTHERS) - f 3' SPLIT RING HANGER awe 3/8' A.T.R. & HILTI DROP—IN ANCHOR 3' X 3' X V CPVC REDUCING TEE----, NO SPARE SPRINKLERS lei' x 116' x V CPVC REDUCING TEE W/ REQUIRED PER NFPA 13D V x V CPVC SPIG ADAPTER GALV. PLUG AND 300 PSI WATER GAUGE & 3—WAY VALVE lYe'xlVA' CPVC REDUCING TEE W/POTTER GLUE IN FLOW SWITCH (WIRED BY OTHERS) i' CPVC BALL VALVE 1%' (PVC CHECK VALVE—�� 1) ' COUP & IVx116" CPVC BUSHING B V CPVC 90° OUT WALL /— TO lb A' SPIGOT ADAPTER OVERHEAD PERMIT TO / & SAWN HEAD START AT 1'-0e A.F.F. o a A 4n DYNAFLOW SLEEVE FROM SUPPLY 1 1/2' PIPE ROTATED FOR CLARITY BY OTHERS CPVC TYPICAL EXPOSED CPVC FIRE SPRINKLER RISER &I\NRE SCALE, NONE Automatic Fire Sprinklers, Inc. TYPICAL SPRINKLER TYPICAL LIGHT I] SI FIXTURE 36' MINIMUM "IN ROOMS/COMPARTMENTS 400 CU, FT, OR LESS, SPRINKLERS MAY BE PLACED REGARDLESS OF LOCATION OF OBSTRUCTIONS. NFPA 13R 6 13D SPRINKLER CLEARANCE W/ LIGHT FIXTURE E SCALE: NONE 1AIAY1� Fire Sprinklers, Inc. 00504N F -QUANTITY SPRINKLERS >YMB IST 2ND I SIN SIZE K TEMP MOM • 1 9 RELIAE O R3516 t' 4,9 155' WHITE ® 1 0 AE R3516 !1' 4,9 175' VHjTF 8 19 1 1 TOTAL PER FLOOR 17 TOTAL PER UNIT 68 TOTAL THIS SHEET • DESIGN AND INSTALLATION TO BE IN ACCORDANCE WITH 2010 EDITION OF NFPA 13D. • DESIGN AND INSTALLATION TO BE IN ACCORDANCE WITH ALL APPLICABLE LOCAL AND STATE CODES. • ALL PIPE AND FITTINGS USED ON THIS PROJECT TO BE IN ACCORDANCE WITH APPLICABLE CODES AND WAFS STANDARDS. SEE PIPE AND FITTINGS GENERAL NOTES (WAFS DETAIL #00593N). • ALL HANGERS SHALL BE DESIGNED AND INSTALLED IN ACCORDANCE WITH NFPA 1.0 AND THEIR LISTING. • ALL PENETRATIONS THROUGH RATED BUILDING ASSEMBLIES SHALL BE SEALED WITH FIRE CAULK IN ACCORDANCE WITH DETAILS PROVIDED. WAFS POLICY IS TO USE HILT[ FS ONE OR STI LCI. • UNDERGROUND MAINS AND LEAD-INS SHALL BE FLUSHED AND SIGNED TEST CERTIFICATES PROVIDED BEFORE A CONNECTION IS MADE TO THE SPRINKLER SYSTEM. • WHEN SYSTEM IS FED USING PLUMBING SERVICE, PIPING SHALL STILL BE FLUSHED PRIOR TO CONNECTING THE SPRINKLER SYSTEM. • ALL PIPING SHALL BE INSPECTED AND APPROVED BY PROPER AUTHORITIES PRIOR TO COVERING WITH DRYWALL. COPIES OF SIGNED TEST CERTIFICATES ARE TO BE FORWARDED TO THE PROPER RECIPIENTS. • ALL SYSTEMS SHALL BE TESTED AT 200 PSI FOR 2 HOURS PER WAFS STANDARDS. • ALL SOFFITS REQUIRED TO CONCEAL SPRINKLER PIPING ARE BY OTHERS. • ALL WIRING OF DEVICES IF PROVIDED (FLOW SWITCHES, TAMPER SWITCHES, ETC) IS BY OTHERS. • VALVES SHALL NOT BE REQUIRED TO BE MONITORED PER FLORIDA BUILDING CODE 903.4 (1). • LOCAL WATERFLOW ALARMS SHALL BE PROVIDED ON ALL SPRINKLER SYSTEMS IN HOMES NOT EQUIPPED WITH SMOKE ALARMS OR SMOKE DETECTORS IN ACCORDANCE WITH NFPA 72, NATIONAL FIRE ALARM CODE. • CONNECTION OF SPRINKLER DEVICES TO THE BUILDING ALARM OR MONITORING SYSTEM, IF PROVIDED, IS BY OTHERS. • ALL PAINTING OF PIPE AS REQUIRED IS BY OTHERS. • ALL INSULATION REQUIRED FOR FREEZE PROTECTION OF SPRINKLER PIPING IS BY OTHERS. • HEATING OF ROOMS TO MAINTAIN TEMPERATURES OF 40 DEGREES OR GREATER IS BY OTHERS. • SPRINKLERS SHALL NOT BE INSTALLED PRIOR TO THE FITTINGS BEING CEMENTED IN PLACE. • ALL SPRINKLERS IN DWELLING UNITS SHALL BE UL LISTED OR FM APPROVED RESIDENTIAL SPRINKLERS. • SPARE SPRINKLERS WILL NOT BE PROVIDED AS THEY ARE NOT REQUIRED BY NFPA 13D. • REFER TO SPACING NOTES ON PLANS FOR MAXIMUM CALCULATED SPACING ALLOWANCES. • SPRINKLERS SHALL BE INSTALLED IN ALL AREAS EXCEPT AS FOLLOWS: o BATHROOMS WHERE THE AREA DOES NOT EXCEED 55 SQ FT. o CLOTHES CLOSETS, LINEN CLOSETS AND PANTRIES WITHIN THE DWELLING UNITS THAT DO NOT EXCEED 24 SQUARE FEET, THE LEAST DIMENSION DOES NOT EXCEED 3 FEET, AND THE WALLS AND CEILINGS ARE SURFACED WITH NONCOMBUSTIBLE OR LIMITED -COMBUSTIBLE MATERIALS AS DEFINED BY NFPA 220, STANDARD ON TYPES OF BUILDING CONSTRUCTION. o ANY GARAGES, OPEN ATTACHED PORCHES, CARPORTS AND SIMILAR STRUCTURES. o ATTICS, PENTHOUSE EQUIPMENT ROOMS, ELEVATOR MACHINE ROOMS, CONCEALED SPACES DEDICATED EXCLUSIVELY TO AND CONTAINING ONLY DWELLING UNIT VENTILAION EQUIPMENT, FLOOR/CEILING SPACES, ELEVATOR SHAFTS, CRAWL SPACES, AND OTHER CONCEALED SPACES THAT ARE NOT USED OR INTENDED FOR LIVING PURPOSES AND DO NOT CONTAIN FUEL -FIRED EQUIPMENT. o COVERED UNHEATED PROJECTIONS OF THE BUILDING AT ENTRANCES/EXITS AS LONG AS THERE IS ANOTHER MEANS OF EGRESS FROM THE DWELLING UNIT, o SPRINKLERS SHALL NOT BE REQUIRED FOR CEILING POCKETS THAT MEET THE FOLLOWING CONDITIONS: 1. THE TOTAL VOLUME OF UNPROTECTED CEILING POCKET DOES NOT EXCEED 100 CU. FT. 2. THE ENTIRE FLOOR UNDER THE UNPROTECTED CEILING POCKET IS PROTECTED BY THE SPRINKLERS AT THE LOWER CEILING ELEVATION. 3. EACH UNPROTECTED CEILING POCKET IS SEPARATED FROM ANY ADJACENT UNPROTECTED CEILING POCKET BY A MINIMUM OF 10 FT. HORIZONTAL DISTANCE. 4. THE INTERIOR FINISH OF THE UNPROTECTED CEILING POCKET IS NONCOMBUSTIBLE OR LIMITED -COMBUSTIBLE MATERIAL. 5, SKYLIGHTS NOT EXCEEDING 32 SQ. FT. SHALL BE PERMITTED TO HAVE A PLASTIC COVER. • WAFS TO PROVIDE ALL REQUIRED SIGNAGE PER NFPA 13D INCLUDING BUT NOT LIMITED TO VALVES, HYDRAULIC PLACARDS, AND INSPECTION TAGS AS REQUIRED BY FS 633. • DEVICES THAT RESTRICT THE FLOW OR DECREASE THE PRESSURE OR AUTOMATICALLY SHUT OFF THE WATER TO THE SPRINKLER SYSTEM, SUCH AS WATER SOFTENERS, FILTRATION SYSTEMS, AND AUTOMATIC SHUTOFF VALVES, SHALL NOT BE ADDED TO THIS SYSTEM WITHOUT A REVIEW OF THE FIRE SPRINKLER SYSTEM BY A FIRE PROTECTION SPECIALIST. Fire sprk&6M him '."""u rn � (ANY MODEL IS ACCEPTABLE PROVIDED PLAN VIEW OF BLADES IS 50% OPEN) NFPA 13R & 13D SPRINKLER CLEARANCE W/ CEILING FAN �!® SCALE, NONE 11"aAYI� Fire Sprinklers. Inc. 00505N NFPA 13D 2010 GENERAL NOTES SCALE, NONE 00678N W B J B For W Willow ON vul Birch Birch Willow 1146 143 i 142 139 DATE SUBMITTALS By 09/13/16 QA REVIEW MPF I i I N0. I DATE REVISIONS BY A I x I LOTS 139-146 �._.. w THORNEBROOKE TOWNHOMES I' WHITE CEDAR ROAD SANFORD FL 32771 19, AIM." I TAYLOR MORRISON HOMES 151 SOUTHHALL LANE, SUITE 200 Automatic Fire Sprinklers, Inc. MAITLAND, FL 32751 MAIN OFFICE — ORLANDO, FLORIDA SHEET TITLE. REDWOOD UNIT FIRE SPRINKLER LAYOUT DRAVN BY, MICKEY FERGUSON 222 CAPITOL COURT OCOEE, FLORIDA 34761 TOTAL us 144 PHONE: (407) 656-3030 FAX: (407) 656-9026 DATE,SEPTEMBER 12, 2016 JACKSONVLLE FL TAMPA, FL POMPANO BEACH, FL AH1 CITY OF SANFORD 11325 DISTRBIlTION AVE WEST 3228 CHERRY PALM DRIVE 3121 NW 16TH TERRACE 84194 JACKSONVILLE FL 32258-2745 TAMPA, FL 33819-IM7 POMPANO BEACH, FL 33064-1408 CONTRACT # NE: PHO(904) 288-3030 PHONE (613) 830-0303 PHONE (954) 9T7-3030 FAX: MAI) 268-0724 FAX: (813) 630-0312 FAX: (954) en -9424 CENTER OF TILE JOB? [—] YES NO I CENTER ON FIXTURES J13B4 Q YES FT. MYER3. R. CONICOFID. NC STATE LICENSES: SHEET # CONSTRUCTION TYPE, 4693 LAREDO AVE 4370 MOTDRSPORT DRIVE NC SPRINICLER: 29745 FT. ERS, FL 33905-4924 CONCORD, 28027-8977 NC ALARM SPRINKLER- SP LV V-13 PHONE (238) 433-3030 PHONE: (700 4) 792-3032 SC SPRPMLER 1118 OCCUPANCY, FAX: (239 263 ) 433-3FAX: (704) 795-FPRO 6838 SC ALARA: 3395 R-3 i� 00 2' 1' 0 4' 8' n, 117771 SCALE 1/4' = Y 1ST FLOOR 2ND FLOOR WILLOW UNIT FIRE PROTECTION PLAN (2,059 SQ. FT.) HICs ELEivIE:NTS NOTE IMPORTANT OWNER ITTEORGMATION RAF' FIRE SPRINKLER CONSTRUCTION DRAWINGS AND SHOP N H P DRAWINGS MAY INCLUDE THIS DRAWING IS BASED ON THE OWNER'S ACCEPTANCE OF THE CURRENTLY ADOPTED BACKGROUND DRAWINGS OR GRAPHICS BORROWED FROM THE ARCHITECTURAL. CIVIL, EDITION (EITHER STATE OR LOCAL) OE NFPA 25 AS THE APPLICABLE STANDARD FOR STRUCTURAL, OR MEP DRAWINGS. THESE REFERENCE BACKGROUND ELEMENTS ARE FOR THE INSPECTION, TESTINGAND MAINTENANCE OF WATER BASED FIRE PROTECTION GENERAL INFORMATION OR CONTEXT ONLY AND THE FIRE SPRINKLER ENGINEER DOES SYSTEMS, PER SECTION 4.1, THE RESPONSIBILITY FOR PROPERLY MAINTAINING A NOT ACCEPT ANY RESPONSIBILITY FOR THESE ELEMENTS, THE FIRE SPRINKLER WATER BASED FIRE PROTECTION SYSTEM SHALL BE THAT OF THE OWNER, IF THE ENGINEER IS ONLY RESPONSIBLE FOR THOSE PORTIONS OF' THE FIRE SPRINKLER BUILDING OWNER HAS NOT RECEIVED A COPY OF THIS PAMPHLET AND/OR IS NOT DRAWINGS DEPICTING FIRE SPRINKLER SCOPES OF WORK. REFER TO APPROVED FAMILIAR WITH THE OPERATION AND MAINTENANCE OF THIS SYSTEM, PLEASE CONTACT ARCHITECTURAL, STRUCTURAL, MEP OR CIVIL DRAWINGS FOR AUTHORITATIVE THE NEAREST OFFICE OF WAYNE AUTOMATIC FIRE SPRINKLERS, INC. EXPRESSIONS or BACKGROUND INFORMATION THAT MAY BE UTILIZED IN FIRE SPRINKLER DRAWINGS OR DETAILS CPVC COMPATIBILITY NOTICE CPVC FIRE SPRINKLER PIPING SYSTEMS HAVE BEEN USED SUCCESSFULLY FOR MORE THAN 20 YEARS IN NEW CONSTRUCTION, RE -PIPE AND REPAIR. CPVC PRODUCTS ARE IDEALLY SUITED FOR THESE APPLICATIONS DUE TO THEIR OUTSTANDING CORROSION RESISTANCE, OCCASIONALLY, HOWEVER, CPVC CAN BE DAMAGED BY CONTACT WITH CHEMICALS FOUND IN SOME CONSTRUCTION MATERIALS (IE SOME WIRES, FLUX, PETROLEUM BASED PRODUCTS, ETC.) AND ANCILLARY PRODUCTS SUCH AS THREAD SEALANTS, LEAK DETECTORS, FIRESTOPS, ETC. ANY PRODUCT THAT COMES IN CONTACT WITH CPVC SPRINKLER PIPE MUST BE EVALUATED IN ACCORDANCE WITH THE SYSTEM COMPATIBILITY PROGRAM AS FOUND AT WWW,SYSTEMCOMPATIBLE.COM COPYRIGHT ALL DOCUMENTS, INCLUDING ORIGINAL DRAWINGS, SPECIFICATIONS, FIELD NOTES, ESTIMATES AND DATA, INCLUDING COMPUTER PROGRAMS PURSUANT TO THIS PROJECT ARE AND WILL REMAIN THE PROPERTYOF WAYNE AUTOMATIC FIRE SPRINKLERS, INC. (WAFS) AS INSTRUMENTS OF SERVICE. THEY ARE NOT INTENDED, NOR REPRESENTED TO BE SUITABLE FOR RE -USE BY THE CLIENT, ITR OTHERS, ON EXTENSION OF THIS PROJECT, OR FOR ANY OTHER PROJECT, ANY REUSE, OR ADAPTATION OF THE NFORMATION CONTAINED HEREIN, WITHOUT SPECIFIC WRITTEN PERMISSION FROM WAFS WILL BE AT THE CLIENTS SOLE RISK, WITHOUT LIABILITY, OR LEGAL EXPOSURE TO WAFS, AND WILL ENTITLE WAFS TO FURTHER COMPENSATION AT RATES TO BE AGREED ON BETWEEN WAFS AND THE CLIENT, THE CLIENT SHALL ALSO INDEMNIFY AND HOLD WAFS HARMLESS FROM ANY AND ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES, INCLUDING ATTORNEYS FEES RESULTING FROM ANY SUCH PERMISSIONS. WATER SUPPLY INFORMATION MAXIMUM DESIGN CRITERIA 0 ® 1616' U.N.O. ACTUAL DROUGHT OR EXTRAPOLATED (AS REQ'D BY AHJ) FIRE PUMP Redwood SYSTEM / DESIGN A t W-1 W-2 6 SIZE, GPM @ PSI OCCUPANCY R-3 HAZARD a SS NFPA 13D NFPA 13D 18 STATIC PRESSURE 66 PSI ITOTAL THIS SHEET HYDRANT ELEV, 2' # OF SPRINKLERS IN DESIGN AREA 2 1 RESIDUAL PRESSOR 56 PSI DATE OF TEST 09/06/16 MINIMI DENSITY ,05 .05 FLOW IN GPM 1010 GPM TIME OF TEST &00 AM DESIGN AREA S.F. 2 SPRKS 1 SPRKS PITOT READING 16 PSI NUMBER OF PORTS FLOWED 1 PSI REo,D a BV 39.5 40,7 TEST PROVIDED BY WAYNE AUTOMATIC FIRE SPRINKLERS, INC. GPM RE(YD a Dv 32,9 20.0 PSI REWD a HYD 53.9 50.7 GN REWD e HYD 37.9 25.0 ELEVATION R HIGHEST SPRINKLER 19'-8' 31'-0' HYDRANT LOCATION OR NUMBER TEST HYDRANT LOCATED ON WHITE CEDAR ROAD HOSE llE N/A N/A DIKSTIC DENAND 5 GPM 5 GPM DESIGN AREA #W-P- EM IW-22ND FLOOR UHT W OWNERS SLATE COMPARTMENT DESIGN PER NFPA 130, 2010 EDITION, SECTION 8.12 DW320' X 20' SPACING `20,0 GPM @ 16,7 PSI WEE 00853N DESIGN AREA IIW-1 2M FLOOR UNIT W COMM AREA =FARTMIM DESIGN PER NFPA 130, 22010 EDITION, SECTION 8.12 WI 16' X 16' SPACING 13,0 GPM @ 7,0 PSI W2 18' X 18' SPACING �nKNNIE17,0 GPM @ 12.0 PSI 00853N =j r SPRINKLERS SPACING SYMBOL MAXIMUM MINIMUM COMMENTS 0 ® 1616' U.N.O. 8' BETWEEN SPRINKLERS 8'4 IMAX SPAUNG OFF WALL U.N.O. DEUCTOR TO BE INSTALLED 1'4 BELOW COUNG Redwood Redwood Birch Birch Redwood 6 12 OCCUPANCY R-3 TOTAL PER FLOOR 3 18 TOTAL PER UNIT 36 ITOTAL THIS SHEET 6' 120VAC BELL W/WEATHERPROOF BACK BOX LOCATE ON OUTSIDE WALL OF BUILDING (WIRED BY OTHERS) :1r 3' X 3' X V CPVC REDUCING TEE ----:- 1%' x lib' x V CPVC REDUCING TEE W/ I' x !' CPVC SPIG ADAPTER GALV, PLUG AND 300 PSI WATER GAUGE & 3 -WAY VALVE 3'x1Vx1' CPVC REDUCING TEE— W/POTTER GLUE IN FLOW SWITCH (WIRED BY OTHERS) 3' CPVC CHECK VALVE 1t' COUP & ItIX 11 CPVC BUSHING 8 OVERHEAD PERMIT T( START AT T-0' A.F.F. DYNAFLOW SLEEVE ----- FROM SUPPLY 11/2' BY OTHERS CPVC Fire Sprinklers, Inc. TYPICAL SPRINKLER 36' MINIMUM v CL TO SPRINKLER SYSTEM SEE UNIT PLANS FOR CONTINUATION WOOD FLOOR TRUSS SPLIT RING HANGER 3/8' A.T.R. & HILTI DROP-IN ANCHOR NO SPARE SPRINKLERS REQUIRED PER NEPA 13D V CPVC BALL VALVE V CPVC 90' OUT WALL %- TO VA' SPIGOT ADAPTER / & SAWN HEAD PIPE ROTATED FOR CLARITY TYPICAL EXPOSED CPVC FIRE SPRINKLER RISER SCALE, NONE TYPICAL LIGHT Sf FIXTURE 'IN ROOMS/COMPARTMENTS 400 CU, FT. OR LESS, SPRINKLERS MAY BE PLACED REGARDLESS OF LOCATION OF OBSTRUCTIONS. NFPA 13R Er 13D �� G`DDIAIIli CO f%1 C A D A (Uf•C W/ 1 IP_LIT CIVTI IGC YNE JGALLI NUNL Fire Sprinklers. Ino. 00504N r -QUANTITY--, SYMB IST 6 2ND 12R3516 SPRINKLERS I I SIN SIZE K TEMP MODEL 4,9 155' RELIABLE MODEL F1 RES, PEND, WHITE W/ RECESSED ESCS, MICKEY FERGUSON TDTAL us ;` DATE, '� Ire Redwood Redwood Birch Birch Redwood 6 12 OCCUPANCY R-3 TOTAL PER FLOOR 3 18 TOTAL PER UNIT 36 ITOTAL THIS SHEET • DESIGN AND INSTALLATION TO BE IN ACCORDANCE WITH 2010 EDITION OF NFPA 13D. IR DESIGN AND INSTALLATION TO BE IN ACCORDANCE WITH ALL APPLICABLE LOCAL AND STATE CODES. • ALL PIPE AND FITTINGS USED ON THIS PROJECT TO BE IN ACCORDANCE WITH APPLICABLE CODES AND WAFS STANDARDS. SEE PIPE AND FITTINGS GENERAL NOTES (WAFS DETAIL #00593N). w ALL HANGERS SHALL BE DESIGNED AND INSTALLED IN ACCORDANCE WITH NFPA 130 "AND'THEIR LISTING. w ALL PENETRATIONS THROUGH RATED BUILDING ASSEMBLIES SHALL BE SEALED WITH FIRE CAULK IN ACCORDANCE WITH DETAILS PROVIDED. WAFS POLICY IS TO USE HILT[ FS ONE OR STI LCI. it UNDERGROUND MAINS AND LEAD-INS SHALL BE FLUSHED AND SIGNED TEST CERTIFICATES PROVIDED BEFORE A CONNECTION IS MADE TO THE SPRINKLER SYSTEM. • WHEN SYSTEM IS FED USING PLUMBING SERVICE, PIPING SHALL STILL BE FLUSHED PRIOR TO CONNECTING THE SPRINKLER SYSTEM. • ALL PIPING SHALL BE INSPECTED AND APPROVED BY PROPER AUTHORITIES PRIOR TO COVERING WITH DRYWALL. COPIES OF SIGNED TEST CERTIFICATES ARE TO BE FORWARDED TO THE PROPER RECIPIENTS. • ALL SYSTEMS SHALL BE TESTED AT 200 PSI FOR 2 HOURS PER WAFS STANDARDS. • ALL SOFFITS REQUIRED TO CONCEAL SPRINKLER PIPING ARE BY OTHERS. • ALL WIRING OF DEVICES IF PROVIDED (FLOW SWITCHES, TAMPER SWITCHES, ETC) IS BY OTHERS. • VALVES SHALL NOT BE REQUIRED TO BE MONITORED PER FLORIDA BUILDING CODE 903.4 (1). • LOCAL WATERFLOW ALARMS SHALL BE PROVIDED ON ALL SPRINKLER SYSTEMS IN HOMES NOT EQUIPPED WITH SMOKE ALARMS OR SMOKE DETECTORS IN ACCORDANCE WITH NFPA 72, NATIONAL FIRE ALARM CODE. • CONNECTION OF SPRINKLER DEVICES TO THE BUILDING ALARM OR MONITORING SYSTEM, IF PROVIDED, IS BY OTHERS. • ALL PAINTING OF PIPE AS REQUIRED IS BY OTHERS. • ALL INSULATION REQUIRED FOR FREEZE PROTECTION OF SPRINKLER PIPING IS BY OTHERS. iN HEATING OF ROOMS TO MAINTAIN TEMPERATURES OF 40 DEGREES OR GREATER IS BY OTHERS. • SPRINKLERS SHALL NOT BE INSTALLED PRIOR TO THE FITTINGS BEING CEMENTED IN PLACE. III ALL SPRINKLERS IN DWELLING UNITS SHALL BE UL LISTED OR FM APPROVED RESIDENTIAL SPRINKLERS. • SPARE SPRINKLERS WILL NOT BE PROVIDED AS THEY ARE NOT REQUIRED BY NFPA 13D. • REFER TO SPACING NOTES ON PLANS FOR MAXIMUM CALCULATED SPACING ALLOWANCES. iN SPRINKLERS SHALL BE INSTALLED IN ALL AREAS EXCEPT AS FOLLOWS: o BATHROOMS WHERE THE AREA DOES NOT EXCEED 55 SQ FT. o CLOTHES CLOSETS, LINEN CLOSETS AND PANTRIES WITHIN THE DWELLING UNITS THAT DO NOT EXCEED 24 SQUARE FEET, THE LEAST DIMENSION DOES NOT EXCEED 3 FEET, AND THE WALLS AND CEILINGS ARE SURFACED WITH NONCOMBUSTIBLE OR LIMITED—COMBUSTIBLE MATERIALS AS DEFINED BY NFPA 220, STANDARD ON TYPES OF BUILDING CONSTRUCTION. o ANY GARAGES, OPEN ATTACHED PORCHES, CARPORTS AND SIMILAR STRUCTURES. o ATTICS, PENTHOUSE EQUIPMENT ROOMS, ELEVATOR MACHINE ROOMS, CONCEALED SPACES DEDICATED EXCLUSIVELY TO AND CONTAINING ONLY DWELLING UNIT VENTILAION EQUIPMENT, FLOOR/CEILING SPACES, ELEVATOR SHAFTS, CRAWL SPACES, AND OTHER CONCEALED SPACES THAT ARE NOT USED OR INTENDED FOR LIVING PURPOSES AND DO NOT CONTAIN FUEL—FIRED EQUIPMENT. o COVERED UNHEATED PROJECTIONS OF THE BUILDING AT ENTRANCES/EXITS AS LONG AS THERE IS ANOTHER MEANS OF EGRESS FROM THE DWELLING UNIT. o SPRINKLERS SHALL NOT BE REQUIRED FOR CEILING POCKETS THAT MEET THE FOLLOWING CONDITIONS: 1. THE TOTAL VOLUME OF UNPROTECTED CEILING POCKET DOES NOT EXCEED 100 CU. FT. 2. THE ENTIRE FLOOR UNDER THE UNPROTECTED CEILING POCKET IS PROTECTED BY THE SPRINKLERS AT THE LOWER CEILING ELEVATION. 3. EACH UNPROTECTED CEILING POCKET IS SEPARATED FROM ANY ADJACENT UNPROTECTED CEILING POCKET BY A MINIMUM OF 10 FT. HORIZONTAL DISTANCE. 4. THE INTERIOR FINISH OF THE UNPROTECTED CEILING POCKET IS NONCOMBUSTIBLE OR LIMITED—COMBUSTIBLE MATERIAL. S. SKYLIGHTS NOT EXCEEDING 32 SQ. FT. SHALL BE PERMITTED TO HAVE A PLASTIC COVER. ik WAFS TO PROVIDE ALL REQUIRED SIGNAGE PER NFPA 13D INCLUDING BUT NOT LIMITED TO VALVES, HYDRAULIC PLACARDS, AND INSPECTION TAGS AS REQUIRED BY FS 533. • DEVICES THAT RESTRICT THE FLOW OR DECREASE THE PRESSURE OR AUTOMATICALLY SHUT OFF THE WATER TO THE SPRINKLER SYSTEM, SUCH AS WATER SOFTENERS, FILTRATION SYSTEMS, AND AUTOMATIC SHUTOFF VALVES, SHALL NOT BE ADDED TO THIS SYSTEM WITHOUT A REVIEW OF THE FIRE SPRINKLER SYSTEM BY A FIRE PROTECTION SPECIALIST. Fir■ 8prkidere. bm �3 '. -I�"" inn (ANY MODEL IS ACCEPTABLE PROVIDED PLAN VIEW OF BLADES IS 50% OPEN) NFPA 13R Er 130 SPRINKLER CLEARANCE W/ CEILING FAN �E SCALE= NONE Automatle Fire Sprinklers, Inc. OOSOSN NFPA 130 2010 GENERAL NOTES SCALD NONE 00678N / fR WILLOW UNIT FIRE SPRINKLER LAYOUT R MICKEY FERGUSON TDTAL us ;` DATE, '� Ire Redwood Redwood Birch Birch Redwood Redwood145 CONSTRUCTION TYPE, V -f3 OCCUPANCY R-3 14 4:14 3 14 2 141,14 0 DATE SUBMF17AIS BY 09/13/16 1 QA REVIEW MPF N0. DATE REVISIONS BY NO 1 *1 IN A, If 777.",7", LOTS 139-146 THORNEBROOKE TOWNHOMES WHITE CEDAR ROAD - SANFORD, FIL 3Z I I I vv \vj6m m Automatic Fire Sprinklers, Inc. MAIN OFFICE - ORLANDO, FLORIDA 222 CAPITOL COURT OCOEE. FLORIDA 34761 PHONE: (407) 656-3030 FAX: (407) 656-9026 JACKSONVLLE, FL TAMPA. FL POMPANO BEACH. FL 11328 DISTRIBUTION AVE. WEST 3228 CHERRY PALM DRIVE 3121 NW 18TH TERRACE JACKSONVLLE FL 32258-2745 TAMPA, FL 33619-8337 POMPANO BEACH. FL 33084-1408 PHONE: (904) 266-3030 PHONE (813) 830-0303 PHONE: (954) 917-3030 FAX (904) 288-0724 FAX: (813) 630-0312 FAX: (954) 97-9424 FT. MYERS. FL CONCORD. NC STATE LICENSES: 4683 LAREDO AVE 4370 MOTDRSPORT DRIVE INC SPRWLER: 29745 FT. MYERS,FL 33906-4924 r CONCORD, NC 28027-8977 NC ALARM: 29222 SP LV PHONE: (239) 433-3030 PHONE: (704) 782-3032 SC SPRINKLER 1118 FAX: (239) 433-3263 FAX (704) 795-8838 SC ALARM:. 3385 TAYLOR MORRISON HOMES 151 SOUTHHALL LANE, SUITE 200 MAITLAND, FL 32751 SHEET TITLE, WILLOW UNIT FIRE SPRINKLER LAYOUT DRAWN It MICKEY FERGUSON TDTAL us 144 DATE, SEPTEMBER 12, 2016 AHJ CITY OF SANFORD BRACT # 184194 CENTER OF TILE JOB? [:] YES 4Z N13 I CENTER 13N FIXTURES JOB? ❑ YES 0 NO SHEET 0 FPW.1 CONSTRUCTION TYPE, V -f3 OCCUPANCY R-3