111 Laguna Ct 17-2071; RENOVATIONSCITY OF SANFORD BUILDING & FIRE PREVENTION PERMIT APPLICATION D Application No: Documented Construction Value: S 62.199.45 Job Address: 111 Laguna Q -Sanford, FL 32773 Historic District: Yes No ElParcelID: 10-20-30-503-0400-0530 Residential X Commercial Type of Work: New Addition AlterationEl Repair Demo Change of Use Move Description of Work: Interior and exterior renovations - See attached scope of work Plan Review Contact Person: FJx Title: /Lc?Srt ui[. Phone: `% -Sb'_E( Fax: 4fv7-32Z-' 6i// Email: Qmbel-GGh:u r,• Property Owner Information Name Andre Green Phone: 407-878-4246 Street: 111 Laguna Ct Resident of property? : Yes City, State Zip: Sanford, FL 32773 Contractor Information Name Corinthian Builders. Inc. Phone: 407-403-5658 Street: 2175 Marquette Ave Fax: 407-322-8641 City, State Zip: Sanford, FL 32773 State License No.: CGC 058246 Architect/Engineer Information Name: Phone: Street: Fax: City, St, Zip: E-mail: Bonding Company: Mortgage Lender: Add ress: Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. % Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has `7 commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. 1 understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: 5" Edition (2014) Florida building Code Revised June 30, 2015 Permit Application NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal. The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value, credit will be applied to your permit fees when the permit is issued. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. o12 Signature of 0%vner/Agent Date IA&JAr L. Print Owner/Agent's Name C Signature of o ary•Stat o ida Date 0*4 MARIACORVILLE x0011 My COMMISSION 9 GG 051629 EXPIRES: December 27. 2020 Banded Ttw Budget Noisy Ser*" Owner/Agent is Personally Known to Me or Produced ID __L,::Type of ID ':D.L__ Signat a Contractor/Agent Date Print Contractor/Agent's Name Kt12 v 0,n R") 7 Signature of Notary -State of Florida Date cOM ° / k MARIACORVILLE MY COMMISSION 9 GG 051629 EXPIRES: December 27, 2020 Baided TM BWPI NOtsy Savkes Contractor/Agent isPersonally Known to Me or Produced 1D Type of ID BELOW IS FOR OFFICE USE ONLY Permits Required: BuildingFf Electrical [( Mechanical 2 Plumbing Gas Roof Construction Type: Occupancy Use: Total Sq Ft of Bldg: Min. Occupancy Load: New Construction: Electric - # of Amps Fire Sprinkler Permit: Yes No # of Heads APPROVALS: ZONING: Z ILITIES: ENGINEERING: iM-TI;-7-%t-1-1 FIRE: COMMENTS: ZL Flood Zone: ?C- c At; kC tib of Stories: Plumbing - # of Fixtures Fire Alarm Permit: Yes No WASTE WATER: BUILDING: 7 Revised June 30, 2015 Permit Application 6/28/2017 SCPA Parcel View: 10-20-30-503-0400-0530 Property Record Card DMo 0 0"'tf>t Parcel: 10-20-30-503-0400-0530 P Owner: GREEN ANDRE L SR Property Address: 111 LAGUNA CT SANFORD, FL 32773 arcel Information Parcel 110-20-30-503-0400-0530 2017 Working Owner GREEN ANDRE L SR Property Address 111 LAGUNA CT SANFORD, FL 32773 Mailing 111 LAGUNA CT SANFORD, FL 32773-5545 Subdivision Name HIDDEN LAKE PH 2 UNIT 1 Tax District S1-SANFORD DOR Use Code 01 -SINGLE FAMILY Exemptions 00-HOMESTEAD(1997) Legal Description LOT 53 BLK 4 HIDDEN LAKE PHASE II UNIT I PB 24 PGS 15 TO 17 Taxes Value Summary Tax Amount without SOH: $900.00 2016 Tax Bill Amount $519.00 Tax Estimator Save Our Homes Savings: $381.00 Does NOT INCLUDE Non Ad Valorem Assessments J Taxing Authority 2017 Working i 2016 Certified Taxable Value Values Values Valuation Method Cost/Market Cost/Market Number of Buildings 1 1 Depreciated Bldg Value 78,820 69,060 Depreciated EXFT Value 400 400 Land Value (Market) 25,000 21,000 Land Value Ag 66,948 46,948 Just/Market Value " 104,220 90,460 Portability Adj 45,600 Yes Improved Save Our Homes Adj 37,272 24,889 Amendment 1 Adj P&G Adj 0 0 Assessed Value 66,948 65,571 Tax Amount without SOH: $900.00 2016 Tax Bill Amount $519.00 Tax Estimator Save Our Homes Savings: $381.00 Does NOT INCLUDE Non Ad Valorem Assessments J Taxing Authority Assessment Value Exempt Values LOT 0.00 0.00 1 $25,000.00 $25,000 Taxable Value County General Fund 66,948 46,948 20,000 City Sanford 66,948 46,948 20,000 County Bonds 66,948 46,948 20,000 Schools 66,948 30,000 36,948 SJWM(Samt Johns Water Management) 66,948 46,948 20,000 Sales Depth Units I Units Price Land Value LOT 0.00 0.00 1 $25,000.00 $25,000 Description I Date Book Page Amount I Qualified Vac/Imp WARRANTY DEED 8/1/1996 3116 0786 67,000 Yes Improved PROBATE RECORDS 1/1/1996 03022 0787 100 No Improved WARRANTY DEED 4/1/1981 01331 1472 45,600 Yes Improved Find Comparable Sales ; Land Method Frontage Depth Units I Units Price Land Value LOT 0.00 0.00 1 $25,000.00 $25,000 Building Information Is Bed/Bath count incorrect? Click Here. f< Description Year Built I Fixtures I Bed Bath Base Area Total SF Living SF Ext Wall Adj Value Repl Value Appendages Actual/Effective http://pareeldetail.scpafl.org/PareelDetailinfo.aspx?PID=10203050304000530 1/2 Board of County Commissioners WORK ORDER SEMINOLE COUNTY, FLORIDA Work Order Number: 31 Master Agreement No.: CC-9192-13/A4M Dated: April 7, 2014 Master Agreement Title: IDSA for Community Services Residential HOME. SHIP NSP _& CDBG Rehabilitations Protect Title: Rehab 0 -';ect at 170 Cogntr• CIsub C-.--!s/y 11 1 Cog, rt, Sanford cl 32 Contractor: Corinthian Builders Inc. 2175 Marquette Ave. _ Sanford, FL 32773 ATTACHMENTS TO THIS WORK ORDER: METHOD OF COMPENSATION: X] Scope of services - Attachment "A" X] fixed fee basis X] Addenda - Attachment "B" time basis -not -to -exceed X] Bid/Pay Items- Attachment "C" time basis -limitation of funds X] Rehabilitation Standards - Attachment "D" X] retainage shall be withheld TIME FOR COMPLETION: The Work to be provided by the CONTRACTOR shall be substantially completed as described In subsection 14.13 of the General Conditions, within ninety (90) calendar days- after the date when the Contract Time begins to run as provided in subsection 2.2 of the General Conditions. The Work shall be finally completed, ready for Final Payment in accordance with subsection 14.9 of the General Conditions, within fifteen (15) calendar days after the actual date of Substantial Completion. Failure to meet the completion time shall be grounds for Termination of both the Work Order and the Master Agreement for Default. WORK ORDER AMOUNT: SEVENTY-TWO THOUSAND TWO HUNDRED SEVENTY-FIVE AND NO/100 DOLLARS ($72.275.00,] IN ITNESS WHEREOF the parties hereto have made and executed this Work Order on this O! S day of20 for the purposes stated herein. fN!S S --T , -m '4' OONVIP'7vn w me m.ym ATTEST/WITNESS: Corinthian Builders Inc. By, Secretary Riichard/Kovacsik, President CORPORATE EAL) Date: 6/) Z- / /7 WITNESSES: 0urement Analyst) Ltqti. 44 Procurement Analyst) OC #811479 Work Order- Contracts, Rev 11/14/11 BOARD OF COUNTY COMMISSIONERS SEMINOLE COUNTY, FLORIDA By:AL.;—ole,U 4 Diane Reed, Procurement Administrator Date: \M_ 0e_ 07/. W/7 As authorized by Section 3.554 Seminole County Administrative Code. CERTIFIED COPY • GRANT MALOY OM #495 CLERK OF THE CIRCUIT COURT AND COMPTROLLER , SEMIPAE COIANTY, MKIDq' 3 ' WORK ORDER TERMS AND CONDITIONS a) Execution of this Work Order by the COUNTY shall serve as authorization for the CONTRACTOR to provide, for the stated project, services as set out in the Scope of Services attached as Exhibit "A" to the Master Agreement cited on the face of this Work Order and as further delineated in the attachments listed on this Work Order. b) Term: This work order shall take effect on the date of Its execution by the County and expires upon final delivery, inspection, acceptance and payment unless terminated earlier in accordance with the Termination provisions herein. c) The CONTRACTOR shall provide said services pursuant to this Work Order, its Attachments, and the cited Master Agreement (as amended, if applicable) which is incorporated herein by reference as If it had been set out in its entirety. d) Whenever the Work Order conflicts with the cited Master Agreement, the Master Agreement shall prevail. e) CONTRACT PRICE: 1) COUNTY shall pay CONTRACTOR for performance of the Work in accordance with the Contract Documents on the basis of the Total Bid (Work Order Amount). The CONTRACTOR's total compensation is DOLLAR ($) subject only to increases or decreases made in strict conformance with the Contract Documents. li) CONTRACTOR agrees to accept the Contract Price as full compensation for doing all Work, furnishing all Materials, and performing all Work embraced in the Work Order Documents; for all loss or damage arising out of performance of the Work and from the action of the elements or from any unforeseen or unknown difficulties or obstructions which may arise or be encountered In the prosecution of the Work until the Final Acceptance; and for all risks of every description connected with the Work. III) The CONTRACTOR acknowledges that CONTRACTOR studied, considered, and included in CONTRACTOR's Total Bid (Work Order Amount) all costs of any nature relating to: 1) performance of the Work under Central Florida weather conditions; 2) applicable law licensing, and permitting requirements, 3) the Project site conditions, Including but not limited to, subsurface site conditions; 4) the terms and conditions of the Contract Documents, including, but not limited to, the indemnification and no damage for delay provisions of the Contract Documents. iv) The CONTRACTOR acknowledges that performance of the Work will Involve significant Work adjacent to, above, and In close proximity to Underground Facilities Including utilities which will require the support of active utilities, as well as, the scheduling and sequencing of utility Installations, and relocations (temporary and permanent) by CONTRACTOR. 1) In addition to the acknowledgements previously made, the CONTRACTOR acknowledges that the CONTRACTOR's own study of Underground Facilities, utilities in their present, relocated temporary and permanent) and proposed locations, and conflicts relating to utilities and Underground Facilities. 2) The CONTRACTOR acknowledges that CONTRACTOR's Total Bid (Work Order Amount) considered and included all of CONTRACTOR's costs relating to CONTRACTOR's responsibilities to coordinate and sequence the Work with the work of the COUNTY and its own forces, the work of other utility contractors and the work of others at the Project site. Work Order—Contracts, Rev 11/14/11 Page 2 of 3 f) PAYMENT PROCEDURES. i) CONTRACTOR shall submit applications for payment in accordance with Section 14 of the General Conditions. Applications for Payment will be processed by ENGINEER as provided in the General Conditions. II) Progress Payments. COUNTY shall make progress payments on the basis of CONTRACTOR's applications for payment as recommended by ENGINEER, In with Section 14 of the General Conditions. III) Final Payment. Upon Final Completion and acceptance of the Work In accordance with subsection 14.9.1 of the General Conditions, COUNTY shall pay the remainder of the Contract Price as provided In subsection 14.9.1. g) ADDITIONAL RETAINAGE FOR FAILURE TO MAINTAIN PROGRESS ON THE WORK. i) Retainage under the Contract Documents is held as collateral security to secure completion of the Work. ii) In the event that CONTRACTOR fails to physically mobilize to the Work required by Section 6.19 of the General Conditions, then the COUNTY may withhold retainage to secure completion of the Work In an amount equal to the product of the number of Days after the 31s' Day following the Date of Commencement of Contract Time liquidated damage amount for Substantial Completion set forth in Section 9 of this agreement. The additional retainage shall be withheld from the initial and each subsequent Progress Payment. The additional retainage held under this subsection shall be released to CONTRACTOR In the next Progress Payment following the ENGINEER's approval of a supplementary Progress Schedule demonstrating that the requisite progress will be regained and maintained as required by Section 6.19.2 of the General Conditions. iii) COUNTY may withhold additional retainage In anticipation of liquidated damages equal to the product of the number of Days after the scheduled Contract Time (Substantial Completion or Final Completion) and the amount of liquidated damages set forth in this Agreement If CONTRACTOR is behind schedule and it is anticipated by COUNTY that the Work will not be completed within the Contract Time. The additional retainage, under this subsection, may at the COUNTY's discretion be withheld from subsequent Progress payments. Any additional retainage held under this subsection shall be released to CONTRACTOR in the next Progress Payment following the Project Manager's approval of a supplemental Progress Schedule demonstrating that the requisite progress will be regained and maintained as required by Sections 6.19.2 of the General Conditions. h) LIQUIDATED DAMAGES. i) The COUNTY and CONTRACTOR recognize that time Is essential to the performance of this Agreement and CONTRACTOR recognizes that the COUNTY and Its traveling public will suffer financial loss if the Work is not substantially completed as described in subsection 14.13 of the General Conditions and within the time specified in this Agreement, plus any extensions thereof allowed in accordance with Section 12 of the General Conditions. The parties also recognize the delays, expense and difficulties involved in proving in a legal or alternative dispute resolution proceeding the damages resulting from inconvenience to the traveling public Including traffic loading, intersection operations, costs for time, costs of fuel and costs for some environmental Impacts (excluding actual delay damages which may include, but are not limited to, engineering fees and inspection costs) suffered by the COUNTY If the Work is not competed on time. Accordingly, CONTRACTOR and CONTRACTOR's Surety agree to pay COUNTY as liquidated damages, and not as a penalty, —Two -Hundred Fifty Dollars ($250.00) per Day for each Day CONTRACTOR exceeds the Contract Time for Substantial Completion until the Work is Substantially Complete. It Is agreed that if this Work in not Finally Completed In accordance with the Contract Documents, the CONTRACTOR shall pay the COUNTY as liquidated damages for delay, and not as a penalty, one-fourth (1/4) of the rate set forth above. il) The liquidated damages provided In this Section are intended to apply even if CONTRACTOR is terminated, in default, or if the CONTRACTOR has abandoned the Work. Work Order— Contracts, Rev 11/14/11 Page 3 of 3 RESOURCE MANAGMENT DEPARTMENT PURCHASING AND CONTRACTS DIVISION Date: June 29, 2017 rY7 lY SL -w 1/1\1011. cou/ /I Y Via Email: office(cDcbiamerica.com rick(cDcbiamerica.com amber&cbiamerica.com Ref: CC -9192-13 Work Order 31 — Rehabilitation of 170 Country Club Circle and 111 Laguna Court, Sanford, FL 32771 NOTICE TO PROCEED The services provided by your firm shall begin on June 30, 2017, and be substantially completed within Ninety (90) calendar days on September 27, 2017. These services shall reach final completion within Fifteen (15) calendar days thereafter on October 12, 2017, as described in the contract documents. The timely and accurate performance of the work set forth in the contract documents is important to the County. It is also a primary consideration for contractor selection on future projects. Please acknowledge below, retain a copy for your records and return one scanned copy to the Seminole County Purchasing and Contracts Division. We are glad to have you on as part of the County's project team and we look forward to a successful project. Sincerely, Tony Durrum, CPPB, A.P.P. Sr. Procurement Analyst Phone :( 407)-665-7123 Fax (407)-665-7956 E-mail: tdurrum(cr.seminolecountyfl.gov ACCEPTANCE OF NOTICE Acceptance of the above "NOTICE TO PROCEED" is hereby acknowledged, this _ day of 2017 .--- By:, Title: cc: Community evelopment/Joe Sandley Finance/File 1301 EAST SECOND STREET - SANFORD FL 32771-1468 - TELEPHONE (407) 665-7116 - FAX (407) 665-7956 V"\/\•\'.SE-IINOLE000NTYFL.GOV/PURCHASING THIS INSTRUMENT PREPARED BY: Name: A. Corville Address: 2175 Marquette Ave Sanford FL 37773 NOTICE OF COMMENCEMENT State of Florida County of Seminole Permit Number: GRANT 11ALOY r SEMINOLE COUNTY CLERK OF C:IRC:UIT COURT r, COPIPTROLLER BK 3946 P9 1923 (1P93) CLERK'S : 2017067972 RECORDED 07/115/2017 1:12:91:17 PH RI:.C:11RD1NG FEES $10.00 RECORDED BY hdevore Parcel ID Number: 10-20-30-503-0400-0530 The undersigned hereby gives notice that improvement will be made to certain real property, and in accordance with Chapter 713. Florida Statutes, the following information is provided in this Notice of Commencement. DESCRIPTION OF PROPERTY: (Legal description of the property and street address if available) LOT 53 BLK 4 HIDDEN LAKE PHASE II UNIT I PB 24 PBS 15 TO 17 GENERAL DESCRIPTION OF IMPROVEMENT: Interior and exterior renovations including reroof OWNER INFORMATION: Name. Andre Green Address: 111 Laguna Ct - Sanford FL 32773 Fee Simple Title Holder (if other than owner) Name: Address: CONTRACTOR: Name: Corinthian Builders, Inc. Address: 2175 Marquette Ave - Sanford, FL 32773 Persons within the State of Florida Designated by Owner upon whom notice or other documents may be served as provided by Section 713.13(1)(b), Florida Statutes. Name: Address: In addition to himself, Owner Designates of To receive a copy of the Lienors Notice as Provided in Section 713.13(1)(b), Florida Statutes. Expiration Date of Notice of Commencement (The expiration date Is 1 year from date of recording unless a different date Is specified) WARNING TO OWNER- ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART I, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. Under penalties of perjury, I declare that I have read the foregoing and that the facts stated in it are true to the best 9f my n wledge d belief. 14 Zg:rl* Owners Signature Owners Printed Name Florida Statute 713.13(1)(g): - The owner must sign the notice of commencement and no one else may be permitted to sign in his or her stead' Ct.fa of -6— County of 6em iyi{A` The foregoing Instrument was acknowledged before me this 3o day of \Xu tic , 20 11 by Pm( e- . Who Is personally known to me Name of person making stattement OR who has produced identification Q -f pe of Identification produced: '-D- I—' ornce By Drp"J: 4UL 0 5 201 i MARIACORVILLE MY COMMISSION f GG 051629 EXPIRES: December 27, 2020 Banded TNu Budget Novy Seel 11 Notary Signature City of Sanford Planning and Development Services Engineering — Floodplain Management Flood Zone Determination Request Form Name: Amber Corville Firm: Corinthian Builders, Inc. Address: 2175 Marquette Avenue City: Sanford State: FL Zip Code: 32773 Phone: 407.403.5658 Fax: Email: amber@cbiamerica.com Property Address: 111 Laguna Court Property Owner: Andre Green Parcel identification Number: 10-20-30-503-0400-0530 Phone Number: 407.878.4246 Email: The reason for the flood plain determination is: New structure Existing Structure (pre -2007 FIRM adoption) Expansion/Addition Existing Structure (post 2007 FIRM adoption) Pre 2007 FIRM adoption = finished floor elevation 12" above BFE Post 2007 FIRM adoption = finished floor elevation 24" above BFE (Ordinance 4360) OFFICIAL USE ONLY •'. ' Flood Zone. X Base Flood Elevation: NSA Datum: N/A FIRM Panel Number: 120294 0070 F Map Date: Sept. 28, 2007 The referenced Flood Insurance Rate Map indicates the following: The parcel is in the: floodplain floodway A portion of the parcel is in the: floodplain floodway M The parcel is not in the: floodplain floodway The structure is in the: floodplain floodway The structure is not in the: floodplain floodway If the subject property is determined to be flood zone 'A', the best available information used to determine the base flood elevation is: BP# 17.2071 Reviewed by: Michael Cash, CFM Date: July 11, 2017 LIMITED POWER OF ATTORNEY Altamonte Springs, Casselberry, Lake Mary, Longwood, Sanford, Seminole County, Winter Springs Date: 06 28 17 7 I hereby name and appoint: an agent of. Corinthian Builders, Inc. Name of Company) to be my lawful attorney-in-fact to act for me to apply for, receipt for, sign for and do all things necessary to this appointment for (check only one option): The specific permit and application for work located at: 111 Laguna Ct - Sanford, FL 32773 Street Address) Expiration Date for This Limited Power of Attorney: 12 31 17 License Holder Name: Richard Kovacsik State License Number: CGC 058246 Signature of License Holder: STATE OF FLORIDA COUNTY OF1c- The foregoing instru ent was acknowledged before me thisday of 200 i' , by r• tCr,Cc :IC.. who is per Wally known to me r o who has produced identification and who did (did not) take an oath. Signature Notary Seal) M A '. a (12 ; Print or type name Ao t !!k' MARIA CORVILLE C. MY COMMISSION: cc051mNotary Public - State of of EXPIRES: DecemDer27.2020 — f,'Ferroas TW% ftM Commission No. My Commission Expires: Rev. 08.12) as JJ City of Sanford Residential Alteration / Addition / Renovation Permit Application Guidelines All permit application packages must be complete prior to acceptance. You must check each box to the left or indicate n/a on this submittal. A complete application package shall include the following: PERMIT APPLICATION AND SUBMITTAL REQUIREMENTS t,X Building Permit Application completed, signed and notarized. Nl r Floodplain development application completed and signed if any portion of the property is in a flood hazard area as identified on the most current flood insurance rate map. 1 I/ Copy of a contract, signed by the contractor and he property owmr, iddicating the documented VVV / construction value Application must include correct address and complete parcel I.D. number. Contractor information is required to be included on the permit application (if contractor is applicant). Applicant must include the name of the designated plan review contact person, their phone number and either a fax number or email address on the Building Permit Application form. Copy of the contractor's license issued by the State of Florida (if contractor is applicant). A site specific notarized power of attorney shall be required from the licensed contractor if he/she appoints an employee of his/her company to sign the permit application as the contractor. Certificate of insurance indicating worker's compensation insurance coverage and naming the City of Sanford as certificate holder, or copy of a worker's compensation exemption issued by the State of Florida (must be submitted with each application if contractor is the applicant). 1 Completed and signed Owner Builder Statement / Affidavit (if owner is applicant). Two (2) copies of all applicable plans and related documentation. C, An accurate, signed and sealed, property survey which shows all improvements on the subject property and within 10 feet on adjacent parcels. Plot plan showing location of proposed improvement(s) and setbacks to property line(s). May need to include infill lot requirements. Hand -drawn submittals must be submitted on plain white paper and include accurate dimensions, all details that apply to the project, and must be legible. Please see the following pages for construction document submittal guidelines ** Revised: February 2016 Page 1 of 5 Residential Alter/Add Permit Application Checklist THE CONSTRUCTION DOCUMENTS MUST INCLUDE, AT A MINIMUM, THE FOLLOWING, AS APPLICABLE: SITE PLAN / PLOT PLAN Must indicate the location of the proposed addition. Two (2) copies are required BUILDING PLAN —Structural If any elements of the addition, alteration or renovation involve altering the structure or any structural elements, the following information must be included and must be signed and sealed by a registered design professional. Any alteration or change to an exterior wall is considered structural and requires signed and sealed engineered plans. O Two (2) copies of construction documents are required. O Construction documents shall indicate code edition being applied O Construction type O Plans to minimum scale O Designer infor ion: name, address, registration #, seal and signature on all signed/sealed pages D Page size ' imum I I" x 17" D All pa numbered and labeled f Wi design data required on drawings per FBC 1603.1.4 to meet 139 mph ultimate design wind speed 1 f risk category 11 buildings (residential) 0 Ultimate design wind speed (Vult) 0 Nominal design wind speed (Vasd) 0 Risk category 0 Exposure category 0 Enclosure classification 0 Internal pressure coefficient 0 Component and cladding design wind pressures in terms of psf 0 Structural Calculations, if necessary 0 Zetingmust include a layout of the entire home 0 An floor plan and a proposed floor plan must be provided, indicating any structural/non- ements, electric, mechanical, plumbing, concrete slabs, and any other relevant details. te the area that will be altered/renovated 0 Each room must be labeled (Kitchen, Bathroom, Bedroom, Living Room, ect.) 0 Must be legible and to minimum 1/4" scale Include all applicable span lengths and dimensions, including porches Revised February, 2016 Page 2 of 5 Residential Alter/Add Permit Application Checklist ELEVATION (if applicable) O At 'c ventilation O oof pitch I Roofing material Exterior finish/stucco thickness 0 Height/bearing elevations O Window and door opening locations O Chimney location/height ENERGY JCALCULATIONS O quired for Additions / Removing existing insulation and adding new insulation Converting unconditioned space to conditioned space. Form 402 or Form 405 FOUNDATION / SLAB O Foundatio plan O Filled c Is with reinforcement locations O Foot denotation/details O Fo ers minimum 12" below grade 1 erior bearing walls/pads orch pads/footers Brick ledge detail 1 O Slab thickness/steel/fiber mesh Vapor barrier/termite treatment type Reinforcing steel over lap D Relieving arch steel at pipe penetrations O All wood minimum 6" above grade O Crawl space ventilation ELECTRICAL (if applicable) Please note: any renovation, alteration or addition will require the entire home to be updated wish smoke detectors, located as required for new construction per FBCR R314 Level I Alterations will require 10 year, non -removable battery smoke detectors. O Electrical existing floor plan and proposed floor plan for the work area. Location of receptacles, switches, lighting, fans, disconnecting, service panels, ect. Electrical ce riser diagram (for new service, service rebuilds or upgrades to service size) Bonding/Grounding load calculations Re -wire of 50% or more of home Additions, required on existing home to verify service size is sufficient' O GFCI protection D AFCI protection O Tamper resistant outlets O Smoke/CO alarm locations Revised.• February 2016 Page 3 oj5 Residential Alter/Add Permit Application Checklist MECHANICAL (if applicable) D Equipment location Anchorage for condenser, engineered to meet wind loads Exhaust rotection in garage locations learances at equipment tructural detail for air handler in attic ntilation dding or modifying ductwork requires a duct layout. uct layout must include a floor plan and indicate the duct sizes, R -value, register sizes ath exhausts size and termination Dryer exhaust discharge/make up air D Energy calculations with equipment sizing calculations for new HVAC installations PLU NG if applicable) Plumbing drain, waste and vent schematic for new plumbing installations I. Bathroom or Kitchen existing floor plan and proposed floor plan. FUEL GAS (if applicable) D BTUs each outlet and total BTUs D P' Oe type and total length D P regulator and model type D Combustion air vents Location of equipment 70003 Venting Gas Type Gas Pressure Gas piping riser F D /Truss I. D. #s dr• Layout, required on plans and a copy included with truss package Signed/Sealed truss engineering package Strapping/fasteners/truss tie -downs DETAIL SHEETS OR NOTES D Footings D Beam to wall and/or post attachments D Post/( mn and beam construction rr bearing walls section ney construction er construction framing construction d windows D Bay windows D Frame to block connections D Knee wall construction D Sky light framing D Top plate splicing requirements Revised: February 2016 Page 4 of 5 Residenlial Alter/Adel Permil Application Checklist O Steel requirements (footer, lintel, vertical pour) Grade Over lap O Veneer O Shear all locations and construction Connectors Fasteners O,/ of sheathing & diaphragms I • Fasteners Blocking j Wall and gable sheathing fastening O Gable end, frame and block, vaulted and flat Conventionally framed roof members Glass block O Header schedule, including strapping/anchorage and frame supports (bearing walls) D Bearing/non-bearing wall detail O Typical wall section detail, one and two story, block and frame, for all scenarios Connectors Anchorage bolts Materials and assembly MANUFACTURER'S PRODUCT INSTALLATION INSTRUCTIONS Roofing components Orr • Underlayment Shingles /Tile/ TPO /Rolled Off -ridge vents Window and mullion installation instructions Garage door, sliding glass door and swing door installation instructions Siding installation instructions Soffit installation instructions Glass block installation instructions Engineered lumber products installation instructions PRODUCT APPROVAL Completed Sanford Product Approval specification sheet Florida Product Approval can be located at www.floridabuilding.org. Product Approval must be approved under the current code edition FS 553.842, FAC 61 G20-3 These guidelines were compiled to assist the applicant in preparing a residential alteration / addition / renovation permit application submittal and may not be complete. The applicant is required to meet all city of Sanford, state, and federal requirements. Rerised: February2016 Page 5 of 5 Resideniial Aber/Add Pernut Application Checklist RFIFn;:,)c Opy 111 Laguna Ct — Scope of Work 1. Replace interior doors 2. Replace exterior doors 3. Replace windows 4. Replace sliding glass door 5. Plumbing a. Repipe house b. Replace water heater c. Replace kitchen sink and faucet d. Replace master bathroom toilet, sink, faucet e. Replace hall bathroom tub, toilet, sink, faucet 6. Replace kitchen and bathroom cabinets in existing locations 7. HVAC a. New 15 SEER HVAC system (air handler & condenser) 8. Electrical a. Replace outlets and switches throughout including GFCI b. Install hardwired smokes/combos c. Replace interior light fixtures d. Install two new exterior GFCI — one at front, one at right side 9. Drywall repairs as required 10. Paint interior and exterior 11. New tile flooring in areas not already tiled 12. Replace cabinets and countertops in kitchen and bathroom 13. New aluminum soffit and fascia 14. Reroof 2 2tc s S ARA E `I2`^t L IcE s> ¢ C.rl1 kC ro aE' JO S't"Q.JGTVRAt_ /.,_101J-STQVCT JRAI I2.AMt1JC P R t'fi-. IFVIEWED FOR CODE COMPLIANCE F PLANS EXAMINER i- IQ- t -Z DATE SANFORD BUILDING DIVISION A PERMIT ISSUED SHALL BE CONSTRUED TO BE A UAENSE To PROCEED S Ofi0 UTHORITY TOLATE C NCEL, ALTER OR SET SANE ASIDE ANY OF THE PROVISIONS OF THE TECHNICAL v CODES. NOR SHALL ISSUANCE OF A -ERMIT PREVENT VCFgR `' THE BUILDING OFFICIAL FROM THEREAFTERREOUIRINGACORRECTIONOFERRORSO7CONSTRUCTONORVOLATIONSOTHSCODEj ', 7 f q'/ X ZV ANlnk) A-a.c-A r I I ° O EV Z O n` v 1 ;0 City of Sanford Building and Fire Prevention Product Approval Specification Form O\LDIAiG, Permit # _ SANFORD Project Location Address 111 Laguna Ct - Se ord, FL 32771 As required by Florida Statute 553.842 and Florida Administrative Code 9N-3, please provide the information and product approval number(s) on the building components listed below if they are to be utilized on the construction project for which you are applying for a building permit. We recommend that you contact your local product supplier should you not know the product approval number for any of the applicable listed products. Be aware that windows, skylights, and exterior doors must be tested in accordance with the Florida Building Code, Section 1714.5. More information about Statewide Product Approval can be obtained at www.floridabuildin-g.org. The following information must be available on the jobsite for inspections: 1. This entire product approval form 2. A copy of the manufacturer's installation details and requirements for each product. Category / Subcategory Manufacturer Product Description Florida Approval # include decimal 1. Exterior Doors Swinging Plastpro Series N Fiberglass door FL15180.11 Sliding Sectional Roll U Automatic Other 2. Windows Single Hung PGT Industries 5400 SH FL239.9 Horizontal Slider Casement Double Hun Fixed Awning Pass Through Projected Mullions PGT Industries Mullions FI -261-R9 Wind Breaker Dual Action Other June 2014 Category / Subcategory Manufacturer Product Description(including Florida Approval # decimal 3. Panel Walls Siding Soffits Storefronts Curtain Walls Wall Louver Glass block Membrane Greenhouse E.P.S Composite Panels Other 4. Roofing Products Asphalt Shingles Underla ments Roofinq Fasteners Nonstructural Metal Roofing Wood Shakes and Shingles Roofing tiles Roofing Insulation Waterproofing Built up roofing System Modified Bitumen Single Ply Roof Systems Roofing slate Cements/ Adhesives / Coating Liquid Applied Roofing Systems Roof Tile adhesive Spray Applied Polyurethane Roofing E.P.S. Roof Panels Roof Vents Other June 2014 Category / Subcategory Manufacturer Product Florida Approval # Description include decimal S. Shutters Accordion Bahama Colonial Roll u Equipment Other 6. Skylights Skylights Other 7. Structural Components Wood Connectors / Anchors Truss Plates Engineered Lumber Railing Coolers/Freezers Concrete Admixtures Precast Lintels Insulation Forms Plastics Deck / Roof Wall Prefab Sheds Other 8. New Exterior Envelope Products Applicant's Signature Applicant's Name Corinthian Builders, Inc. Please Print) June 2014 3/1/2017 Florida Building Code Online r. •:i,' Cl'.'. j! [',,Ki eM!.i.+,_s.`-, I: ,r i__':,t M te! 3 ,,, • i I' '.="•.' ! ,::t[;:.-_ Ulu BCIS Home Log In ' User Registration Hot Topics t Submit Surcharge Stats b Facts Publications FBC Staff SCIS Site Map Links Search bo Product Approval USER: Public User s -':-.vim ;;.r,• Product Approval Menu > Product or Application Search > Application Lost > Application Detail e ::'tr • r W,, FL # FL15180-R1 Application Type Revision Code Version 2014 Application Status Approved Comments Archived Product Manufacturer Plastpro Inc. / Nanya Plastics Corp. Address/Phone/Email 5200 W CENTURY BLVD. LOS ANGELES, CA 90045 440) 969-9773 Ext 16 rickw@rwbldgconsultants.com Authorized Signature Vivian Wright rickw@rwbldgconsultants.com Technical Representative Scott Johnson Address/Phone/Email 5200 W Century Blvd. Los Angeles, CA 90045 440) 969-9773 Ext 18 scottjohnson@plastproinc.com Quality Assurance Representative Ron O'Connell Address/Phone/Email 5200 W Century Blvd. Los Angeles, CA 90045 440) 969-9773 Ext 16 ronoconnell@plastpro.com Category Exterior Doors Subcategory Swinging Exterior Door Assemblies Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer V Evaluation Report- Hardcopy Received Florida Engineer or Architect Name who developed Lyndon F. Schmidt, P.E. the Evaluation Report Florida License PE -43409 Quality Assurance Entity National Accreditation and Management Institute Quality Assurance Contract Expiration Date 12/31/2018 Validated By Ryan J. King, P.E. Validation Checklist - Hardcopy Received Certificate of Independence FL15180 R1 COI CERTIFICATE of INDEPENDENCE.Ddf Referenced Standard and Year (of Standard) Standard Year ASTM D1929 1996 ASTM D1929 2006 ASTM D2843 1999 ASTM D635 1998 ASTM D638 2003 ASTM E1300 2004 ASTM E84 2005 htips:/M-ww.floridabuilding.org/pr/pr_app Og.aspx?param=wGEVXQwtDgsidcHd6ieP8HCLWJ4zwVnPCNLpdxOYYZiAB\IMYkYFBkA*/o3d%3d 1/5 311/2017 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Summary of Products Go to Page - Florida Building Code Online ASTM G26 TAS 201, 202, 203 Florida Licensed Professional Engineer or Architect FL15180 R1 Eauiv Eauivalencv Of Standards.odf Method 1 Option D 04/24/2015 04/26/2015 04/28/2015 06/23/2015 1995 1994 0O Page 1/20 0 FL # Model, Number or Name Description 15180.1 a. Smooth/Wood 6'8 "Impact" Glazed Fiberglass Single Door - Outswing (X - Grain/Rustic/Mahogany Series N Configuration) Fiberglass Door Limits of Use Installation Instructions Approved for use in HVHZ: Yes FLIS180 R1 If Inst 15180.1.Ddf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 15180.1 for Design Pressure Ratings, any FL15180 R1 AE Eval 15180.1.0f additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. 15180.2 b. Smooth/Wood 6'8 "Impact" Glazed Fiberglass Single Door with "Impact" Grain/Rustic/Mahogany Series N Sidelite - Outswing (OX or XO - Configuration) Fiberglass Door Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL15180 R1 II Inst 15180.2.Ddf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 15180.2 for Design Pressure Ratings, any FLIS180 R1 AE Eval 15180.2.Ddf additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. 15180.3 c. Smooth/Wood 6'8 "Impact" Glazed Fiberglass Single Door with "Impact" Grain/Rustic/Mahogany Series N Sidelites - Outswing (OXO - Configuration) Fiberglass Door Limits of Use Installation Instructions Approved for use in HVHZ: Yes FLIS180 R1 fl Inst 15180.3.odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 15180.3 for Design Pressure Ratings, any FL15180 R1 AE Eval 15180.3.odf additional use limitations, Installation instructions and product Created by Independent Third Party: Yes particulars. 15180.4 d. Smooth/Wood 6'8 "Impact" Glazed Fiberglass Double Door - Outswing (XX - Grain/Rustic/Mahogany Series N Configuration) Fiberglass Door Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL15180 R1 fl Inst 1S180.4.odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 15180.4 for Design Pressure Ratings, any FLIS180 R1 AE Eval 15180.4.odf additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. 15180.5 I e. Smooth/Wood 16'8 "Impact" Glazed Fiberglass Double Door with "Impact" https //www.floridabuilding.org/pr/pr_app dtl.aspx?param=wGEVXQwtDgsidcHd6ieP8HCLWJ4zwVnPCNLpdxOYYZutBVMYkYFBkA%3d%3d 215 3/1/2017 Florida Building Code Online Grain/Rustic/Mahogany SeriesI Sidelites - Outswing (OXXO - Configuration) Fiberglass Door Limits of Use Installation Instructions Approved for use in HVHZ: Yes FLIS180 RI If Inst 15180.5.Odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 15180.5 for Design Pressure Ratings, any FLIS180 R1 AE Eval 15180.5.odf additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. 15180.6I f. Smooth/Wood Grain Series N 18'0 "Impact" Glazed Fiberglass Single Door - Outswing (X - Fiberglass Door Configuration) Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL15180 R1 If Inst 15180.6.odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 15180.6 for Design Pressure Ratings, any FLIS180 RI AE Eval 15180.6.odf additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. 15180.7 g. Smooth/Wood Grain Series N 8'0 "Impact" Glazed Fiberglass Single Door with "Impact" Fiberglass Door Sidelrte - Outswing (OX or XO - Configuration) Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL15180 RI it Inst 15180.7.odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 15180.7 for Design Pressure Ratings, any FLIS180 R1 AE Eval 15180.7.odf additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. 15180.8 h. Smooth/Wood Grain Series N 8'0 "Impact" Glazed Fiberglass Single Door with "Impact" Fiberglass Door Sidelites - Outswing (OXO - Configuration) Limits of Use Installation Instructions Approved for use in HVHZ: Yes FLIS180 R1 II Inst 15180.8.Odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 15180.8 for Design Pressure Ratings, any FL15180 R1 AE Eval 15180.8.odf additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. 15180.9 i. Smooth/Wood Grain Series N Fiberglass Door 8'0 "Impact" Glazed Fiberglass Double Door - Outswing (XX - Configuration) Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL15180 R1 II Inst 15180.9.odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 15180.9 for Design Pressure Ratings, any FL15180 R1 AE Eval 15180.9.odf additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. additional use limitations, installation instructions and product 15180.10 j. Smooth/Wood Gram Series N 8'0 "Impact" Glazed Fiberglass Double Door with "Impact" Fiberglass Door Sidelites - Outswing (OXXO - Configuration) Limits of Use Installation Instructions Approved for use in HVHZ: Yes FLIS180 R1 II Inst 15180.10.odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 15180.10 for Design Pressure Ratings, any FL15180 R1 AE Eval 15180.10.udf additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. 15180.11 k. Smooth/Wood 6'8 "Impact" Opaque Fiberglass Single Door - Grain/Rustic/Mahogany Series N Inswing/Outswing (X - Configuration) Fiberglass Door Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL15180 R1 II Inst 15180.11.odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 15180.11 for Design Pressure Ratings, any FL15180 R1 AE Eval 15180.Il.odf additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. htips://www.floridabuilding.org/pr/pr_app o.aspx?param=wGEVXQwtDgsidcHd6ieP8HCLWJ4zwVnPCNLpdxOYYZutB\ITAYkYFBkA%3d%3d 315 3/1/2017 Florida Building Code Online 15180.12 I. Smooth/Wood 6'8 "Impact" Opaque Fiberglass Single Door with "Impact" Grain/Rustic/Mahogany Series N Sidelite - Outswing (OX or XO - Configuration) Fiberglass Door Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL15180 R1 Ii Inst 15180.12.odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 15180.12 for Design Pressure Ratings, any FL15180 R1 AE Eva[ 15180.12.odf additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. 15180.13 m. Smooth/Wood 6'8 "Impact" Opaque Fiberglass Single Door with "Impact" Grain/Rustic/Mahogany Series N Sidelites - Outswing (OXO - Configuration) Fiberglass Door Limits of Use Installation Instructions Approved for use in HVHZ: Yes FLIS180 RI II Inst 15180.13.odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 15180.13 for Design Pressure Ratings, any FL15180 R1 AE Eval 15180.13.odf additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. 15180.14 n. Smooth/Wood 68 "Impact" Opaque Fiberglass Double Door - Grain/Rustic/Mahogany Series N Inswing/Outswing (XX - Configuration) Fiberglass Door Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL15180 R1 II Inst 15180.14.odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 15180.14 for Design Pressure Ratings, any FL15180 R1 AE Eval 15180.14.odf additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. 15180.15 o. Smooth/Wood 6'8 "Impact" Opaque Fiberglass Double Door with "Impact" Grain/Rustic/Mahogany Series N Sidelites - Outswing (OXXO - Configuration) Fiberglass Door Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL15180 R1 II Inst 15180.15.0f Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 15180.15 for Design Pressure Ratings, any FL15180 RI AE Eval 15180.15.odf additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. 15180.16 p. Smooth/Wood Grain Series N 8'0 "Impact" Opaque Fiberglass Single Door - Fiberglass Door Inswing/Outswing (X - Configuration) Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL15180 RI II Inst 15180.16.odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 15180.16 for Design Pressure Ratings, any FL15180 R1 AE Eval 15180.16.odf additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. 15180.17 q. Smooth/Wood Grain Series N 8'0 "Impact" Opaque Fiberglass Single Door with "Impact" Fiberglass Door Sidelite - Outswing (OX or XO - Configurations) Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL15180 R1 II Inst 15180.17.odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 15180.17 for Design Pressure Ratings, any FL15180 R1 AE Eval 15180.17.odf additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. 15180.18 r. Smooth/Wood Grain Series N 8'0 "Impact" Opaque Fiberglass Single Door with Sidelites - Fiberglass Door Outswing (OXO - Configuration) Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL15180 R1 II Inst 15180.18.odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes https•//www.floridabuilding.org/pr/pr_app dg.aspx?param=wGEVXQwlDgsidcHd6ieP8HCLWJ4zwVnPCNLpdxOYYZutBVMYkYFBkA%3d%3d 4/5 3/1/2017 Florida Building Code Online Design Pressure: N/A Evaluation Reports Other: See INST 15180.18 for Design Pressure Ratings, any FL15180 R1 AE Eval 15180.18.odf additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. 15180.19 s. Smooth/Wood Grain Series N 80 "Impact" Opaque Fiberglass Double Door - Fiberglass Door Inswing/Outswing (XX - Configuration) Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL15180 R1 II Inst 15180.19.Ddf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 15180.19 for Design Pressure Ratings, any FL15180 R1 AE Eval 15180 19 Ddf additional use limitations, installation Instructions and product Created by Independent Third Party: Yes particulars. 15180.20 It. Smooth/Wood Grain Series N 8'0 "Impact" Opaque Fiberglass Double Door with "Impact" Fiberglass Door Sldelites - Outswing (OXXO - Configuration) Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL15180 R1 II Inst 15180.20.Ddf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 15180.20 for Design Pressure Ratings, any FL15180 R1 AE Eval 15180 20 Ddf additional use limitations, Installation instructions and product Created by Independent Third Party: Yes particulars. Go to Page O Page 1/ 2 0 Sack E Contact US :: 2601 Blair Stone Road. Tallahassee FL 32399 Phone, 850-487.1824 The State of Florida is an WEED employer. Copyright 2007-2013 State of Florida..: Privacy Statement :. Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released In response to a public -records request, do not send electronic mall to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address If they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: E ® KtHI M Credit_ • safe seCUTIi}' AI FTI I https-/Avww.floridabuilding.org/pr/Pr_app_o aspx?param=wGEVXQwtDgsidcHdoieP8HCLWJ4zwVnPCNLpdxOYYZutBVMYkYFBkA%3d%3d 5/5 4. jy L plastpro SHEET Y DESCRIPTION I 5200 W. CENTURY BLVD. 2 LOS ANGELES, CA 90045 Smooth / Wood Grain / White Wood Grain Rustic / Mahogany Series N Fiberglass Door INSWING / OUTSWING lmmcTr GENERAL NOTES I. This product has been evaluated and is in compliance wilh the 5th Edition (2014( Florida Building Code FBC( structural requirements including the "High Velocity Hurricane Zone" (HVHZ(. 2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment to base material shall be beyond wag dressing or stucco. 3. When used In the "HVHr' this product complies with Section 1626 of the Florida Budding Code and does not require an impact resistant covering. 4. When used in areas outside of the "HVHZ" requiring wind borne debris protection this product complies with Section 1609.1.2 of the FOC and does not require an impact resistant covering. This product meets missile level "D" and includes Wind Zone 4 as defined in ASTM El 996 and Section 1609.1.2.2 of the FBC. 5. For 2x stud framing construction, anchoring of these units shag be the some as that shown for 2x buck masonry construction. 6. Site conditions that deviate from the details of Ihis drawing require further engineering analysis by a licensed engineer or registered architect. 7. Oulswing configurations meet water infiltration requirements for "HVHr'. 8. Inswing configurations do not meet the water infiltration requiremenls for the "HVHT'. Inswing units shag be Installed only in non -habitable areas or at habitable locations protected by an overhang or canopy such that the angle between the edge of canopy or overhang to slit is less than 45 degrees. 37.50' MMX.L fRAME W111111IOIH TABLE OF CONTENTS SHEET Y DESCRIPTION I Typical elevation design pressures. 6 general notes 2 Door panel details 3 Horizontal cross sections 4 Vertical cross sections 5 Buck and frame anchoring - 2X buck masonry construction 6 Frame anchoring - I X buck masonry construction 7 Bio of materials b components 37.50' MMX.L fRAME W111111IOIH MAX. - DESIGN PRESSURE (PSF) FRAME-' DIMENSION POSITIVE' NEGATIVE; 37.50" y INSWING x 47.5 47.5 82.00" 37.50" OLITSWING x 50.0 50.0 80.50" r''''•. LL`LL``` y n rill r 1, a Z uN•• Ihh v a;i Q Qgo . 3 d o a 4c u E 0Z ALE' N.T.S rc BY: JK W. er. LFS MiNG NO.; FL -15180.1 1 iEcr I or 7 u F0.81r 1.3r STILE C LOCK BLOCKOMP-) (0 LONG WC2(r LONG WOODI STILE REINFORCEMENT - ENSTILEREINFORCEMENT WOOD) 35.75* MAX. DOOR PANEL WIDTH Ir as - z FDOOR ANEL INTERIOR EXTERIOR O HORIZONTAL CROSS SECTION SEE HARDWARE CHART 0-81' 1.2r HARDWARE TABLE MANUFACTURER MODEL KWIKSETT TOP RAIL OUDiOtt SIGNATURE SERIES (in) TUBE $jtj$ (7$0) COMP.) FOAM CORESTILESTILE COMP.) COMP.1 POLYURETHANE - 1.9 PCF MIN.) STILE REINFORCEMENT WOOD) 4 1 P1 , i . Q ol 0 e . Y . '. 0 c0oNn9os WOVEN FIBERGLASS INTERIOR INTERIOR EXTERIOR SMC SHEET DOOR SKIN MAIL HARDWARE TABLE MANUFACTURER MODEL KWIKSETT KNOB: SIGNATURE $6,11s OUDiOtt SIGNATURE SERIES (in) TUBE $jtj$ (7$0) 1,75* Z 0 0, On 4 1 P1 , i . Q ol 0 e . Y . '. 0 c0oNn9os Cm (L a. z EXTERIOR BOrlOMRAIL --lUl JLJ f COMP.1 rl-'\ VERTICAL CROSS SECTION TE; 02121112 AE N.T.S Ic GY. JK a K 61 LFS AM4G NO - FL -15180.11 - 0 ECT 2 or 7 lo" AS, C -SINK TYP.) INTERIOR 27 EXTERIOR 1 HORIIOWAL CROSS SECTION 3 Outsapprovevnng showdn •inswing also INTERIOR EXTERIOR 1 HORIZONTAL CROSS SECTION 3 Shown w/I X sub -buck 1-I/!" MIN. EMB. (TYP I 1-1//"MW. EMB. (TYP.) 4• v ^ w yam; t Z dm UN •; o 0 Z Ea Z m 3 amd4 C 0 ' Z h a a v O i m O Z Z u ac 0212 1 12 i A. N T.S. ° ro By JK m' EU3 JIFSw: 1510 _ r EXTERIOR T VERTICAL CROSS SECTION 4 Oulswurg shown - inswing also approved INTERIOR 4 .. e e a VERTICAL CROSS SECTION 4 Outswing confgurotion EXTERIOR JK Z( d ` m rrlllll 1 i F777777777h INTERIOR EXTERIOR INTERIOR r1 VERTICAL CROSS SECTION 4 shownwilxsutrbuck 1 VERTICAL CROSS SECTION 4 Inswing configuration See general notes. sheet I tor"WHi wolerinfdlrolion requiements ON z v a oil EP zmau Sd oa 0A 0cZO N id SLI N Q 4 O aai 2 U rt: 02 21/12 z Au. N.r.S 9 e fff JK o D(. BY LFS 3 AWW' N0. C FL -15180 11 o EV 4 OF 7 V D TYP. HEAD b JAMBS MASONRY OPENING 2X BUCK Q BUCK ANCHORING STRIKE JAMB CONCRETE ANCHOR NOTES: 1. Concrete anchor locohons of the comers maybe adjusted to maintain the min, edge distance to mortarjoints. 2. Concrete anchor locations noted as "MAX. ON CENTER" must be adjusted to maintain the min. edge distance to mortar joints. oddifionat concrete anchors may be required to ensure the 'MAX. ON CENTER" dimension are not exceeded. 3. Concrete anchor table - ANCHOR ANCHOR MIN. MIN. CLEARANCE MIN, CLEARANCE TYPE SIZE EMBEDMENT TO MASONRY TO ADJACENT EDGE ANCHOR' Irw TAPCON 1/1" 1 1/1" 2" 4" ELCO ULTRACONa wnnne 1/4" 1-1/4" 1 " 4" 1. Maintain a minimum 5/8" edge distance, I"end distance, d I"o.c. spacing ofwoodscrewstopreventthesplittingofwood. TYP. HEAD 6 JAMBS MASONRY OPENING FRAME 2X BUCK , II III FRAME ANCHORING M0$0rvY 2X buck construclbn HINGE JAMB LATCH B DEADBOLT DETAIL HINGE DETAIL n D J:ci n 2_ w O n O UN0vVuZ E. 9m. v Cd° v Y mad C CZ xN ZO 2'= 2p U In u W o W ZE 5- C2 aG: i oz u o a Yu 7maam SH I i w i N Q i O o ° oZ u°0 rE• 02/2I 12 i ALE N T. S ti JK m] n• LFS 3 AM'Wr NO R Fl -15180.11 O rEl 5 Or 7 N r Y MASONRI OPENING FRAM r I I I Ixsuc STRIKE JAMS CONCRETE ANCHOR NOTES' I. Concrete anchor locclons of the comer may be adjusted to mahtoh the mh edge dklance to n otwlolnh. 2. Concrete anchor locations noted as MAK ON CENTER' muss be odJusfed to maintain the min. edge dklance to mortorjoksh. oddlllvtsol concrete anchors may be mQuhcd to ensure the 'AM Concrete eneh- f.w..• ON CENTER' dhsensbn Gm not aKceeded. J ANCHOR ANCHOR MIN. MIN. CLEARANCE MIN. CLEARANCE TYPE - SIZE ' EMBEDMENT -TOAIASONRY TO ADJACENT. EDGE .: ANCHOR ' ITW TAPCONe 11: 1.1/P j EICO Ul1RACON' 114- 1.1/rITW TAPCONe I 3/IE' 1.1/P T 1. Malntoh o mhknum S/B' edge distance. 1' end distance, a I'o.c. spochg of wood screws to Prevent the spffkrlg of woad. FRAME ANCHORING Masonry IX buck conshuclion HINGE JAMS HINGE DETAIL LATCH A DEADSOLT DETAIL h t. n 0Lan fAn_ o°na0z UN•: v v K Z c0 9meu urn jOrmmaas dz j uz h n w i N Q O z Z U TE 02121112 = All? N.T.S ° C or JK m' K. ffY: LFS 3 AMINO No. a FL -15160 11 0 CET 6 OF 7 e i Q:p dw 2.T --i ., ' p,GJ 2 cIn w HEAD t SIDE ' 1111 11 u r Z 10 Jamb a e i r4t 9mc'w i ma f 4 0 8 '3a I 2.14' 0 21 HEAD L SIDE 5 m POly(Ijamb aQvWi o 1.56' ---{ I i,1 ADJUSTAtlIF INSWING 1TIRESHOLD 34 ADJUSTABLE INSWING THRESHOLD ' J 166' 1.56' i lr ci 2.03' ---j '" W c1i n + 0 0, i OIOSWING BUMP THRESHOLD wre: 02 21 12 10UISWINGiNRESHOIDlYDLP Sc -u N.T.S. owc. m JK cw. By. LFS 5iG NO • FL -15180.11 sNEET 7 O. 7 uz SILL OF MATERIALS DEM 1 DEscRIP11DH MAD?RIAI A I X BUCK SG >= 0.55 B 2X BUCK SG >= 0.55 W000 C 1/4" MAX. SHIM SPACE WOOD D I /4" X 2-3/4' ELCO OR ITW CONCRETE SCREW E MASONRY - 3.000 PSI MIN. CONCRETE CONFORMING TO ACI STEEL 301 OR HOLLOW BLOCK CONFORMING TO ASTM C90 CONCRETE G 3/16"X 3.1 /4"PFH ITW CONCRETE SCREW H 1/4" x 3-1/4" PFH ELCO OR R1N CONCRETE SCREW STEEL 1 1/4" X 2-1/4"Pill ELCO OR ITW CONCRETE SCREW STEEL J 1 /4" X 3.3/4" PFH ELCO OR ITW CONCRETE SCREW STEEL K 9X2- 7'PFH WOOD SCREW STEEL L 8 X 2-1 /7' PFH WOOD SCREW STEEL M 8 X 2"PFH WOOD SCREW STEEL 7 FORCE 5 WEATHERSTRIPPING BY ENDURA STEEL 8 COMPRESSION WEATHERSTRIP OLON 650 BY SCHLEGEL FOAM 9 4" X 4" BUTT HINGE FOAM 10 9 X 1" PFH WOOD SCREW STEEL I I 9 X 3/4" PFH WOOD SCREW STEEL 20 FINGER JOINTED PINE FRAME, HEAD & HINGE JAMBS STEEL 21 POLY FIBER JAMB WOOD COMP. / VINYL27LATCHSTRIKEPLATE 28 DEADBOLT STRIKE PLATE STEEL 29 OUTSWING THRESHOLD BY DLP STEEL ALUM.JWOOD30INSWINGVINYLDOORBOTTOMSWEEPBYENDURA 31 OUTSWING BUMP THRESHOLD VINYL 32 VINYL DOOR BOTTOM SWEEP #3628 BY HOLM IND. ALUM. PVC33INSWINGADJUSTABLETHRESHOLDBYENDURAALUM./WOOD34INSWINGADJUSTABLEALUMINUMTHRESHOLDBYDLPALUM./WOOD40DOORPANEL - SEE DOOR PANEL DETAIL SHEET FOR CONSTRUCTION DETAILS i Q:p dw 2.T --i ., ' p,GJ 2 cIn w HEAD t SIDE ' 1111 11 u r Z 10 Jamb a e i r4t 9mc'w i ma f 4 0 8 '3a I 2.14' 0 21 HEAD L SIDE 5 m POly(Ijamb aQvWi o 1.56' ---{ I i,1 ADJUSTAtlIF INSWING 1TIRESHOLD 34 ADJUSTABLE INSWING THRESHOLD ' J 166' 1.56' i lr ci 2.03' ---j '" W c1i n + 0 0, i OIOSWING BUMP THRESHOLD wre: 02 21 12 10UISWINGiNRESHOIDlYDLP Sc -u N.T.S. owc. m JK cw. By. LFS 5iG NO • FL -15180.11 sNEET 7 O. 7 uz 2/21/2017 Florida Building Code Online r- --- r---rr-- r• ..."•r ^.9-.^::y.iµ; try-_.' _ a -c c}' 1= ' i'(•• ;:s.sf`'I Dt: r `ns ' •. _ I•, cry r J '•, r i . t` y- =.• 3• i1. ''` Et•1.:A'Ln-'cA..i'..i.l l'•-•it j,;. (•Yi '3C J'',j u..:.•'.: •: rt... SCIS a p •t' c.S) ,'. _ nYl°= •i.' ___ .v' _ _ , ``'S'^( 'r'YK7-Y'•'•irr vsrY.r... _ _.._"' i Jviy ',.scst=Jir,+rrrti" SCIS Home ( Log In ( User Registration Hot Topics Submit Surcharge ; Stats G Facts Publications FBC Staff , BCIS Site Map Links Search F li a 1/ 1 r s r Product Approval IUSER: Public User Product Approval Menu > Product or Anplication Search > Application List > Application Detail Application Type Code Version Application Status Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Certification Agency Validated By Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Product Approval Method Date Submitted Date Validated FL239-R23 Revision 2014 Approved Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. PGT Industries 1070 Technology Drive North Venice, FL 34275 941)486-0100 Ext 22318 druark@pgtindustries.com Jens Rosowski jrosowski@pgtindustries.com Jens Rosowski 1070 Technology Drive Nokomis, FL 34275 941) 486-0100 Ext 21140 jrosowskj@pgtindustries.com Windows Single Hung Certification Mark or Listing Miami -Dade BCCO - CER Miami -Dade BCCO - VAL Standard TAS 201, 202, 203 Method 1 Option A 06/28/2016 06/29/2016 Year 1994 https:/NAwtA,.floridabuilding.org/pr/Pr_app dtl.aspx?param=wGEVXQwtDquSiBu8CAEmBE7OC31VX3PGOMFJzgGSVsrS%2ftA2ThCtHX7lg2JHb%2fO62mN5.. 1/3 2/21/2017 Date Pending FBC Approval Date Approved Date Revised Summary of Products Florida Building Code Online 07/03/2016 08/22/2016 FL # Model, Number or Name Description 239.1 SH - 200 (Non -Impact) Aluminum Single Hung Window Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL239 R23 C CAC16-050502„df Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: No 09/01/2021 Design Pressure: N/A Installation Instructions Other: Please see Miami -Dade County Notice of Acceptance FL239 R23 II 16- 505 02 Ddf NOA) for product performance information, anchorage Verified By: Miami -Dade BCCO - CER details, and anchor type, size, and spacing Information. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 1239.2 I SH - 500 (Large Missile Impact) WinGuard Vinyl Single Hung Window Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL239 R23 C CAC 15-0612 12h pdf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: Yes 01/08/2019 Design Pressure: N/A Installation Instructions Other: Please see Miami -Dade County Notice of Acceptance FL239 R23 II 15-0612 12b odf NCA) for product performance information, anchorage Verified By: Miami -Dade BCCO - CER details, and anchor type, size, and spacing information. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 239.3 I SH - 600 (Non -Impact) I Aluminum Single Hung Window Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL239 R23 C CAC 15-0519 07 odf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: No 01/26/2021 Design Pressure: N/A Installation Instructions Other: Please see Miami -Dade County Notice of Acceptance FL239 R23 II 15-0519 07 odf NOA) for product performance information, anchorage Verified By: Miami -Dade BCCO - CER details, and anchor type, size, and spacing information. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 239.4 I SH - 700 (Large Missile Impact) I Aluminum Single Hung Window Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL239 R23 C CAC 15-0519_08pdf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: Yes 03/26/2021 Design Pressure: N/A Installation Instructions Other: Please see Miami -Dade County Notice of Acceptance FL239 R23 II 15-0519 08 odf NOA) for product performance information, anchorage Verified By: Miami -Dade BCCO - CER details, and anchor type, size, and spacing information. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 239.5 I SH - 800 (Large Missile Impact) I Multi -Story Aluminum Single Hung Window Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL239 R23 C CAC 15-0609.02 LM Ddf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: Yes 05/03/2017 DesignPressure: N/A Installation Instructions Other: Please see Miami -Dade County Notice of Acceptance FL239 R23 II 15-0609.02 LM Ddf NOA) for product performance information, anchorage Verified By: Miami -Dade BCCO - CER details, and anchor type, size, and spacing information. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 239.6 SH - 800 (Small Missile Impact) Multi -Story Aluminum Single Hung Window Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL239 R23 C CAC 15-0609.03 SM Ddf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: Yes 05/03/2017 Design Pressure: N/A Installation Instructions Other: Please see Miami -Dade County Notice of Acceptance FL239 R23 II 15-0609.03 SM.Ddf NOA) for product performance information, anchorage Verified By: Miami -Dade BCCO - CER details, and anchor type, size, and spacing information. Created by Independent Third Party: https:/Avww.floridabuilding.org/pr/pr app dd.aspx?param=wGEVXQwtDquSiBu8CAEmBE7OC31VX3PGOMFJzgGSVsrS%2ftA2ThCtHX7Kg2JHb%2fO62mN5.. 2/3 2/21/2017 Florida Building Code Online I Evaluation ReportsICreatedbyIndependent Third Party: 239.7 I SH -3000 (Large Missile Impact) I Architectural Systems Aluminum Single Hung Window Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: Please see Miami -Dade County Notice of Acceptance NOA) for product performance information, anchorage details, and anchor type, size, and spacing information. Certification Agency Certificate FL239 R23 C CAC 1S-0612.11 Lmi.pdf Quality Assurance Contract Expiration Date 12/06/2017 Installation Instructions FL239 R23 II 15-0612.11 LMI Ddf Verified By: Miami -Dade BCCO - CER Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 239.8 I SH -3000 (Small Missile Impact) I Architectural Systems Aluminum Single Hung Window Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: Please see Miami -Dade County Notice of Acceptance NOA) for product performance information, anchorage details, and anchor type, size, and spacing information. 239.9 I SH -5400 (Non -Impact) Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: N/A Other: Please see Miami -Dade County Notice of Acceptance NCA) for product performance information, anchorage details, and anchor type, size, and spacing information. 239.10 I SH -5500 (Large Missile Impact) Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: Please see Miami -Dade County Notice of Acceptance NOA) for product performance information, anchorage details, and anchor type, size, and spacing Information. Certification Agency Certificate FL239 R23 C CAC 15-061 10 SMI Ddf Quality Assurance Contract Expiration Date 12/06/2017 Installation Instructions FL239 R23 II 15-0612.10 SMI Ddf Verified By: Miami -Dade BCCO - CER Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: Vinyl Single Hung Window Certification Agency Certificate FL239 R23 C CA[ 15-051g 06b Ddf Quality Assurance Contract Expiration Date 07/30/2020 Installation Instructions FL239 R23 II 1 -051 06b Ddf Verified By: Miami -Dade BCCO - CER Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: Vinyl Single Hung Window Certification Agency Certificate FL239 R23 C CAC 15-0519 05 Ddf Quality Assurance Contract Expiration Date 07/30/2020 Installation Instructions FL239 R23 II 5-0519 05 Ddf Verified By: Miami -Dade BCCO - CER Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: Contact U . 2601 Blair Stone Road. Tallahassee Fl. 32399 Phone 50-487-1824 The State of Florida is an AA/EEO employer. Coovnoht 2007-2033 State of Florida • • Pnvacv Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronicmailtothisentity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850 487.1395. -Pursuant to Section455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they haveone. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply aDersonaladdress, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter455, F.S., please click here . Product Approval Accepts: o= o Credit Card Safe Mips:/Avww.flondabuildingorg/pr/pr app 00aspx7param=wGEVXQwtDquSlBu8CAEmBE7OC31VX3PGOMFJzgGSVsrS%2flA2ThC(HX71g2JHb%2f062mNS.. 3/3 MM®DA DE MIAMI-DADE COUNTY T PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE (NOA) www.mismidade.gov/economy PGT Industries, Inc. 1070 Technology Drive North Venice, FL 34275 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone. DESCRIPTION: Series "5400" PVC Single Hung Window — N.T. APPROVAL DOCUMENT: Drawing No. MD-SH5400-01 titled "Single Hung Window Installation - NI", sheets 1 through 12 of 12, dated 05/15/15, prepared by manufacturer, signed and sealed by Anthony Lynn Miller, P.E., bearing the Miami -Dade County Product Control Section Approval stamp with the Notice of Acceptance number and approval date by the Miami -Dade County Product Control Section. MISSILE IMPACT RATING: None LABELING: Each unit shall bear a permanent label with 'the manufacturer's name or logo, city, state, model/series, and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA consists of this page 1 and evidence pages E-1 and E-2, as well as approval document mentioned above. The submitted documentation was reviewed by Manuel Perez, P.E. NOA No. 15-0519.06 Expiration Datc: July 30, 2020 1 Approval Date: July 30, 2015 Page I PGT Industries. Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED A. DRAWINGS 1. Manufacturer's die drawings and sections. 2. Drawing No. MD-SH5400-01 titled "Single Hung Window Installation - NI", sheets I through 12 of 12, dated 05/15/15, prepared by manufacturer, signed and sealed byAnthonyLynnMiller, P.E. B. TESTS 1. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202-94 2) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 3) Water Resistance Test, per FBC, TAS 202-94 4) Forced Entry Test, per FBC 2411.3.2.1, and TAS 202-94 5) Large Missile Impact Test per FBC, TAS 201-94 6) Cyclic Wind Pressure Loading per FBC, TAS 203-94 along with marked -up drawings and installation diagram of a series 5500 PVC single hung window, prepared by Fenestration Testing Laboratory, Inc., Test Report No. FTL-7964, dated 11/15/14, signed and sealed by Idalmis Ortega, P.E. C. CALCULATIONS 1. Anchor verification calculations and structural analysis, complying with FBC-511Edition (1014), dated 05/15/15, prepared by manufacturer, signed and sealed by Anthony Lynn Miller, P.E. 2. Glazing complies with ASTM E1300-09 D. QUALITY ASSURANCE 1. Miami—Dade Department of Regulatory and Economic Resources (RER). Manuel e , P E. Product Control E m' er NOA No. 15-0519.06 Expiration Date: July 30, 2020 E Approval Date: July 30, 2015 1 PGT Industries, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED E. MATERIAL CERTIFICATIONS (CONT11 UED) 1. Notice of Acceptance No. 12-1120.02 issued to Royal Window and Door Profiles, Plant 13 for their "White Rigid PVC Exterior Extrusions for Windows and Doors" dated 02/28/13, expiring on 02/28/18. 2. Notice of Acceptance No. 14-0529.13 issued to Royal Window and Door Profiles, Plant 13 for thcir "Bronze and Lighter Shades of Cap Coated Rigid PVC Exterior Extrusions for Windows and Doors" dated 04/16/15, expiring on 04/16/20. 3. Notice of Acceptance No. 14-0529.14 issued to Royal Window and Door Profiles, Plant 13 for their "Performance Core Rigid PVC Exterior Extrusions for Windows and Doors" dated 04/16/15, expiring on 04/16/20. F. STATEMENTS 1. Statement letter of confonmance, complying with FBC -2010 and FBC-51' Edition 2014), dated May 15, 2015, issued by manufacturer, signed and sealed by Anthony Lynn Miller, P.E. 2. Statement letter of no financial interest, dated May 15, 2015, issued by manufacturer, signed and sealed by Anthony Lynn Miller, P.E. 3. Proposal issued by Product Control, dated 6/26/14 and revised on 8/19/14, signed by Jaime Gascon, P.E. Supervisor, Product Control Section. G. OTHERS 1. None. Manuel Per 1z, P. . Product Control Eami er NOA No. l5- .06 Expiration Date: July 30, 2020 Approval Date: July 30, 2015 E-2 EXAMPLE FOR 261/8' MAX.O.C. 1 7MAX. O.C. EQUALLY RADIUS -TOP HEADER (SOA 12' MAX FROM HEADER(SW FORALL 54' MAX. BUCK V41DTH VISIBLE FOR ALL WINDOW TYPES) FRAME SEMI LIGHT y) 30' 12'MAX. HEIGHT B, SEE MAX. 0 C 91, 0 SHEET3 FRAME SEMI D. SEE X B, SEE . SHEET 3 JO' MAX. O.C. 1 moi --12' MAX. A, SEE SHEET 3' j SASH OC I / EQUALLY II SPACED ANCHORSPER / TABLES 687 Q II X EQUALLY L--•'-/// 7 SPACED ANCHORSPER TABLES 887 L i 12' MAK EQUALLY - 17.7/B' MAX.O.C. SPACED ANCHORSPERI— 1ASLES617 _ 84' T MAX. - 10' MAX. O.C. BUCK HEIGHT 54' MA% BUCK WIDTH -) \ I SEE SRL WEEP• NOTCH DETARS, SHEET ELEVATION FOR TYP. EQUAL LEG FRAME SHOWN WITH EQUAL -LITE CONFIGURATION FI%ED VISIBLE LIGHT WIDTH - 1 7MAX. O.C. EQUALLY I FI%ED HEADER(SW FORALL SPACED VISIBLE r ANCHORSPER LIGHT 17.7/8• MAX. O.0 TABLES 667 HEIGHT e MAX. 54' MA% BUCK WIDTH -) \ I SEE SRL WEEP• NOTCH DETARS, SHEET ELEVATION FOR TYP. EQUAL LEG FRAME SHOWN WITH EQUAL -LITE CONFIGURATION MAT(. GHT FI%ED VISIBLE LIGHT WIDTH - 12' MAX I— NOT RATED FOR 1 IMPACT RESISTANCE I FI%ED HEADER(SW FORALL VISIBLE r TYPES) LIGHT 17.7/8• MAX. O.0 HEIGHT 91, 0 BU HEI FRAME SEMI D. SEE X 0. SEESHEET 10*MAXO C. MAK O C -+ 12' j SASH OC11"4*MAX MAX. C. SEE VISIBLE LIGHT HEIGHT A Bat MAX EQ12* UALLY I MAT(. GHT 21.518• ANCHORAGE EXAMPLE MAX O.0 FOR ARCH•70P VARIES PER REINFORCEMENT LEVEL, SEE SHEETS 8-7 NOT RATED FOR 1 IMPACT RESISTANCE HEADER(SW FORALL 1 TYPES) WINDOW 1\510' MAX. FROM FRAME SEMI D. SEE SHEET 0. SEESHEET 30' MAK O C -+ 12' 3 MAX. C. SEE SHEE13i SHEET 4 1 EQ12* UALLY I 70' SPACED) 17-7/B' MAX. O C. ANCHORS PER CK TABLES S d 7 851 MAX X I j f0'MA%10 C. BUCK J HEIGHT I EOUAILY L 13.3/4• MAX O.C. SPACED I 1 I SEEANCHORSPER TABLES687 i SHEETSi1 JNO ANCHORS AT SILL SASH VISIBLE SEE SRL WEEP. LIGHT WIDTH NOTCH DETAILS. SHEET 3 ELEVATION FOR TYP. FLANGE FRAME SHOWN WITH ORIEUPROVIEW CONFIGURATION SEE SILL WEEP - 54' MAX. BUCK WIDTH NOTCH DETAILS, SHEET3 ELEVATION FOR TYP. FLANGE FRAME SHOWN WITH STANDARD COTTAGE CONFIGURATION FOR CUSTOM COTTAGE CONFIGURATION UP TO 75' HEIGHT SEE TABLES 6 8 7GENERALNOTES: SERIES 5400 NON -IMPACT RESISTANT SINGLE HUNG WINDOW 1) THIS PRODUCT HAS BEEN DESIGNED i TESTED TO COMPLY WITH THE REQUIREMENTS OF THE FLORIDA BUILDING CODE, INCLUDING THE HIGH VELOCITY HURRICANE ZONE (HVHZ) 2) SHUTTERS ARE REQUIRED WHEN USED IN WIND-BORNE DEBRIS REGIONS. 3) FOR MASONRY APPLICATIONS IN MIAMI -RADE COUNTY. USE ONLY MIAMI-DADE COUNTY APPROVED MASONRY ANCHORS. MATERIALS USED FOR ANCHOR EVALUA71ONS WERE SOUTHERN PINE, ASTM C90CONCRETEMASONRYUNITSANDCONCRETEWITHMINKSIPERANCHORTYPE. 4) ALL WOOD BUCKS LESS THAN 1-112' THICK ARE TO BE CONSIDERED 1X INSTALLATIONS. 1X WOOD BUCKS ARE OPTIONAL IF UNIT IS INSTALLED DIRECTLY TO SUBSTRATE. WOOD BUCKSDEPICTEDAS2XARE1 -U2 -THICK OR GREATER. 1X AND 2X BUCKS (WHEN USED) SHALL BE DESIGNED AND SECURED TO PROPERLY TRANSFER LOADS TO THE STRUCTURE. WOOD BUCK DESIGNANDINSTALLATIONISTHERESPONSIBILITYOFTHEENGINEER, (EOR) OR ARCHITECT OF RECORD, (AOR). 5) ANCHOR EMBEDMENT TO BASE MATERIAL SHALL BE BEYOND WALL DRESSING OR STUCCO. USE ANCHORS OF SUFFICIENT LENGTH TO ACHIEVE REQUIRED ION EMBEDMENT. INSTALLATION ANCHORSSHOULDBESEALED. OVERALL SEALINGIFLASHING STRATEGY FOR WATER RESISTANCE OF INSTALLATION SHALL BE DONE BY OTHERS AND IS BEYOND THE SCOPE OF THESE INS7RUC710NS. 8) 114• MAX. SHIMS ARE REQUIRED AT EACH ANCHOR LOCATION WHERE THE PRODUCT IS NOT FLUSH TO THE SUBSTRATE. USE SHIMS CAPABLE OF TRANSFERRING APPLIED LOADS. 7) DESIGN PRESSURES, A. NEGATIVE DESIGN LOADS BASED ON STRUCTURAL TESTING AND GLASS PER ASTM E1300. S. POSITIVE DESIGN LOADS BASED ON WATER TEST PRESSURE, STRUCTURAL TESTING AND GLASS PER ASTM E13DO. B) THE ANCHORAGE METHODS SHOWN HAVE BEEN DESIGNED TO RESIST THE WINDLOAOS CORRESPONDING TO THE REQUIRED DESIGN PRESSURE. THE 33-1/3% STRESS INCREASE HAS NOT BEEN USED INTHEDESIGNOFTHISPRODUCT. THE 1.6 LOAD DURATION FO WAS USED FOR THE EVALUATION OF ANCHORS INTO WOOD ANCHORS THAT COME IN70 CONTACT WITH OTHER DISSIMILAR MATERIALSSHALLMEETTHEREQUIREMENTSOFTHEFLORIDABUILDINGCODEFORCORROSIONRESISTANCE. 0) METAL SUBSTRATE TO MEET MIN STRENGTH AND THICKNESS REQUIREMENTS PER CURRENT FLORIDA BUILDING CODE AND TO BE REVIEWED BY THE AUTHORITY HAVING JURISDICTION. 10) REFERENCES: TEST REPORTS FTL-7964; ELCO ULTRACON NOA; ELCO CRE7EFLEX NOA; ELCO AGGRE-GATOR NOA; ROYAL WINDOW AND DOOR PROFILES, LID WH17E 6 BRONZEA.IGHTER SHADES OF CAPCOATEDPVCEXTRUSIONNOKS: NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION, ANSOAFBPA NDS 6 ALUMINUM DESIGN MANUAL11) APPLICABLE EGRESS REQUIREMENTS TO BE REVIEWED BY BUILDING OFFICIAL.17 USER INSTRUCTIONS 1) DETERMINE THE SITE SPECIFIC, WINDOW OPENING'S DESIGN PRESSURE REQUIREMENT FROM ASCE 7. 2) DETERMINE THE MOST SUITABLE ANCHOR GROUP FROM TABLES 2 OR 3 ACCORDING TO THE INSTALLATION CONDITIONS. 3) KNOWING YOUR GLAZING OPTION (TABLE 1), WINDOW CONFIGURATION AND SIRE, DETERMINE YOUR WINDOWS DESIGN PRESSURE FROM TABLES 4 OR S. IT MUST EQUAL OR EXCEED THE DESIGN PRESSURE REQUIREMENT FOR THE WINDOWOPENINGOBTAINEDINSTEP1. DETERMINE ANCHOR QUANTITY FROM TABLES 6 OR 7 VERIFY THE4ET REQUIREMENTSFORYOUROPENEING1CONDITIONFROMTABLES2OR7ANDTHATALLMIN. REOUREMENTS FROM THBSTRATE WILL IS SHEET -SET ARE MET5) INSTALL AS PER SHEET 3 FOR THRU•FRAME INSTALLATION OR SHEET 4 FOR INTEGRAL FIN INSTALLATION. NOTE•DESIGN PRESSURE RATING DETERMINATION IS THE SAME PROCESS FOR ALL FRAME TYPES (J -CHANNEL, FLANGE, INTEGRAL FIN OR EQUAL LEGIBOXJ LYNN l,Nl(!o Q,` T ,.• \GENS/; R is is Nu.58705 I11— SAT OT 1070 TECHNOLOGY DRIVE 0,` FIOR\OP:•'\(2 N. VENICE. FL 34275 941)-480-1600 WNNMRlEl1 PE. P E B 50705 CERT. OF RUTH. 029296 DESIGN PRESSURE RAI ING IMPACT RATING VARIES PER REINFORCEMENT LEVEL, SEE SHEETS 8-7 NOT RATED FOR 1 IMPACT RESISTANCE D '- -J 1.1/4' --; c•- SEE SRL WEEP. NOTCH DETAILS, SIIEET 4 ELEVATION FOR TYP. FIN OR J -CHANNEL FRAME SHOWN WITH EQUAL -LITE CONFIGURATION ANCHORED THROUGH THE NAIL -FIN SIMILAR A14CIlOR DIMENSIONS FOR OTHER CONFIGURATIONS) GENERAL NOTES ......... 1 ELEVATIONS ...... ..... ......... _._.1 FRAME, GLASS B ANCHOR OP71ONS..........._..- _._- ----- 2 INSTALLATION. FLANGE 6 EQUAL LEGIBOX............. 3 INSTALLATION, INTEGRAL FIN 8 J -CHANNEL .............. _.. 4 GLAZING DETAILS ................... 5 DESIGN PRESSURES...._.___....6, 7 ANCHOR QUANTITIES .............. 8.9 EXTRUSION PROFILES..___.._... 10 ASSEMBLY 8 PARTS LIST....._... 11,12 R.O.b.: GENERAL NOTES & ELEVATION J ROSOWSKI nu.: SINGLE HUNG WINDOW INSTALLATION - NI 05/15/15 SH -5400 I NTS I" 1 OF 12 I MD-SH5400-01 Glass Type Description (Llsled from Exterior to Interior) DPetre* 1 3/4" 1 G.: 1/8" A Exterior Cap + 112" Air Space + 1/8" A Exterior Cap 4 0 2 3/4" 1 G.: 1/8" T Exledor Cap + 1/2" Alr Space + 1/8" T Exterior Cap 4.5 6,7 3 3/4" I.G : 3116" A Extedor Cap + 3111'• Air Space + 3116"A Exterior Cap 4.5 8.7 4 314" IG.: 3/18" T Exterior Cap + 3/8" Alr Space + 3/18" T Exledor Cep 4,5 8.7 Group Anchor Substrate Min. Edge Min. P.T. Southern Pine (SG=.55) 3/8• 2-7116' 1 - 4 2.1/2- Wrigahank Rooirp Nall Distance Embedment' 1(s Tiw*head SMS Steel, S.S. a 4100 SS.S.) 10 SMS P.T. Southern Pine (SG=O. 717— 1.3/8' 1 •4 steel, 18.8 S.S. Steel, A36' 3/8' 0.050' Steel, A38' 318' 0.050' or 410 S S.) Steel Stud, A653 Gr. 331 3/8' 0.0451" (18 Ga.) A Squamfflocl., Arch -Top 8 Rafts -Top Aluminum, 6063-75• 318" 0 050" Through the frame of the window...... Into 2X Wood Freme/Buck*Idp - sheet 4, option 6 P.T. Southern Pine (SG=0.55) E318* Nlegrel Fin 3) 1-3/8" Equd•Lte, OdeVPrmlew 6 College3/16' steel Ullracon Concrete (min. 2.85 list) Into 2X Wood Frame/Buckstnp - Sheol 4, option 5 1318' Through the home....Into of the window...... 2X Wood Frams/Buckstdp - sheet 4, option 6 Ungiouled CMU, (ASTM C-90) 1.1/4" 12 SMS P.T. Southern Pine (SG=0.55) 1-318' B steel, 18.8 S.S. Steel, A38' 0.050' or 410 S.S.) Steel Stud, A653 Gr. 330 0451` (18 Ga) Aluminum, 6063-T5' 0.063' 114" steel Ullracon Concrete (min. 2.85 ksi) 1' 1-314" C Ungrouled CMU, (ASTM C-90) 2-1/2' 1-1/4' 114" sleet Creleftex Concrete (min. 3 35 kel) 1" 1-3/4' 114" steel Ullracon Concrete (min. 2.85 ksi) 2-1/2" 1-3/4' 114' steel Ullracon P.T. Southern Pine (SG=0.55) 1' 13-38' 1/4' steel Cretibox Concrete (min 3 35 list) 2.1/2' 13/4' D 1/4' steel Creteflex Ungrouled CMU, (ASTM C-90) 2-112" 1-1/4' P.T. Southern Pine (SG=0.55) 1' 1-318' 1/4" steel Aggre-Gator Concrete (min 3.275 ksi0.5) 1-1/2" 1-318" 1/4' steel Aggre-GaloT P T. Southem Pine SG=5 1' 1 8' Grouted CMU, (ASTM C-90) 1 2' 7' Group Anchor Substrate Min. Edge Min. Distance Embedmenr E 2.117' x .131' Common Nall P.T. Southern Pine (SG=.55) 3/8• 2-7116' 1 - 4 2.1/2- Wrigahank Rooirp Nall P.T. Southern Pine (SG=.55) 318' 2.7118' F 1(s Tiw*head SMS Steel, S.S. a 4100 SS.S.) P T. Southern Pine (SG=.55) 1/2' 1318' Aluminum, 8003-T5' 318' 0050, Steel Stud, Gr. 33' 318'0 0451' (18 Ge.) Steel, A30' 3/0' 0.050' 1 •4 912 SMS steel, 18.8 S.S. or 410 S.S.) P.T. Southern Piro (SG= 55) 9/16' 1318' Aluminum, 6063.751 310' 0.003' Steel Stud, Of. 33' 318' 0050. Steel, A38' 318' 0.050' GLAZING NOTES A' - ANNEALED T• = TEMPERED MIN OF 3 THREADS BEYOND THE METAL SUBSTRATE. FOR STEEL STUDS, MIN Fu -415 KSI& MIN Fy=33 KSI. UNGROUTED CMU' VALUES MAY BE USED FOR GROUTED CMU APPLICATIONS. FIMIRF P- FRAME QHADFQ Fame Types a Fig B) Glass Options a Table 1) Frame Contig*, see Flg A) Frame Shape* see Flg C) Installation Options that may be used Flange 1112) 1 - 4 Equanil*, OnwPrWow A. Cottage SquarNRecl.. Aroh-Top 6 Radius -Top Through The barn* of the vnndow..... Into 2X Wood Fismo/Buckchip - sheet 3, option 1 Into Conclels/CMU - sheet 3, option 2 through 1X Bucksldp Into Conciete/CMU - shoal 3, option 3 Into Motel - sheet 3, option 4 Box / Eq(# 4) a4) 1 •4 EgllPfale, OA. Celle ew A. College Square/Recl , Arch -Top 6 Radius -Top Through the Game of the vdndow..........Ih Into 2X Wood Frome/Buckstdp - sheet 3, option 1 Into Concmlo/CMU - sheet 3, option 2 Dago 1X Backstop Into Cone,ele/CMU - shoal 3, option 3 into Metal - sheet 3, option 4 1Channd R1) 1 -4 Equal•Ule, Odayprodew 6 College Squamfflocl., Arch -Top 8 Rafts -Top Though the Integral in into 2X Wood FrsmdBuekstdp - shoot 4, option 5 Into Molal -wheel 4, option 7 Through the frame of the window...... Into 2X Wood Freme/Buck*Idp - sheet 4, option 6 Into Meld - chest 4, option 8 Nlegrel Fin 3) 1 -4 Equd•Lte, OdeVPrmlew 6 College Squere/Recl., Arch -Top 6 Radius -Top Through the Integral An...... Into 2X Wood Frame/Buckstnp - Sheol 4, option 5 into Metal - sheet 4, option 7 Through the home....Into of the window...... 2X Wood Frams/Buckstdp - sheet 4, option 6 Into Meld - sheet 4, option 6 d A EOUAL-LITE ORIEL COTTAGE BUCK WIDTH BUCK WIDTH moi BUCK WIDTH OF 3 zNo. 58705 THREADSBEYOND THE METAL7. I STEEL STUDS. 1. £TAI =lU Z MIN Fu=46KSIaO MIN. Fy=33 KSI.. it Tle Dro+4P f1o. MD-SH5400-01 N(\-•: CERT. OF AUIH. /29290 A lrYo-mi,116 E. 68705 TUPUP M go O ur RECTANGULAR RADIUS -TOP ARCH -TOP WINUUW SHAPES AS ABOVE OR SIMILAR ARE APPROVED. SHAPES MAY BE USED BY INSCRIBING THE SHAPE IN A BLOCK AND OBTAINING DESIGN PRESSURES AND ANCHORAGE FOR THAT BLOCK SIZE FROM THE TABLES ON SHEETS 6.9. FIM IRF R• FRAME i PVI! I`BOX LYN,y qll'/ GNV RAv1AAd By: OF 3 zNo. 58705 THREADSBEYOND THE METAL7. SUBSTRATE FOR i '• 7rF/5." STEEL STUDS. 1. £TAI =lU Z MIN Fu=46KSIaO MIN. Fy=33 KSI.. it SCC '•,•P(ItIDP,.•'•• 10 Dro+4P f1o. MD-SH5400-01 N(\-•: CERT. OF AUIH. /29290 A lrYo-mi,116 E. 68705 FIM IRF R• FRAME i PVI! I`BOX 4 {' OR EQUAL - I RAv1AAd By: OoIA: RAYIAI011: DAAFrIP1IOli: GLASS/ANCHORS/FRAME OPTIONS Ororn J ROSOWSKI 1070 TECHNOLOGY DRIVE N. VENICE, FL 34275 941)-480-1600 7114:Dor.: SINGLE HUNG WINDOW INSTALLATION - NI 05/15/15 SAr4A/Aladd: ScaleSMAC• SH -5400 NTS 2 OF 12 Dro+4P f1o. MD-SH5400-01 Rw. CERT. OF AUIH. /29290 INSTALLATION DETAILS FOR FLANGE & EQUAL-LEG/BOX FRAMES INSTALLATION OPTION 2 INSTALLATION OPTION 3 INSTALLATION ANCHORED THROUGH FRAME ANCHORED THROUGH FRAME AND 1X OPTION 1 EDGE DISTANCE DIRECTLY INTO CONCRETEICMU. BUCKSTRIP INTO CONCRETEICMU ANCHORED THROUGH SEE NOTE 2. THIS SHEET. I••• EMBEDMENT FRAME INTO 2X WOODEMBEDMENT FRAME OR BUCKSTRIP, 111' MAX SHIM 16 114' MAX SHIM •{ -- SEE NOTE 2, THIS SHEET. EMBEDMENT SASH VISIBLE 17 I •• r 18 IGHT EDGE LWIDTH EDGE FLANGE FRAME SHOWN j L_L o ' ,' DISTANCE ' DISTANCE 44 BALANCEL114' MAX TYPE VARIES - -- TYP ANCHOR SHIM TYP. ANCHOR TYPE, 42 WITH SASH I TYPE, 2 EMBEOMENTAND WEIGHT 54 30 vTYP. ANCHOR TYPE, EMBEDMENT EDGEEMBEDMENTANDEDGE DISTANCE PER SUBSTRATE, DISTANCE PER AND EDGE DISTANCE PER SEE TABLE 2, SHEET 2 SUBSTRATE, IO SEE TABLE 2, SHEET 2. EDGE SUBSTRATE, DISTANCE16EXTERIOR ' \ 87 L \ U SEE TABLE 2, SHEET 2. FIXED 19 Q FIXED VISIBLE VISIBLE 20 OPT. SASH LIFT RAIL TOP FLAN LIGHT WIDTH EOUALI2 GHT HEIGHT I FRAME NOTES: LEWOX SHOWN BUCK WIDTH FOR All WINDOWS FRAME 46 ANCHOR ®355' 1)USE ONLY HORIZONTAL SECTION A -A SHOWN 49 21CENTER FROM END AND AT SUBSTRATE -APPROPRIATE 22 FOR WINDOWS ANCHORS LISTED ON TABLE 2, u 0 SHEET 2. FOLLOW EMBEDMENT ANDOVER38' WIDE: DADE APPROVED MULLION, FBC COMPLIANT ALUMINUMISTEEL FRAMING OR STEEL STUD. EDGE DISTANCE LIMITS. ANYADDADDITIONAL MAY BE VERTICAL OR HORIZONTAL. SEE SUBSTRATE PROPERTIES, TABLE 2, SHEET 2. INSTALLATION OPTION SHOWN MAY 1q 45 46 47 35 SCREWS ®16-316' FROM ENO. BE USED ON ANY SIDE OF THE O WINDOW. FOR WINDOWS "T"114' MN( DUCK SO I (EIGHT 16aO BOTTOM LOCKS. 2) MASONRY ANCHORS MAY BE SHIM 010 OR 012 STEEL 114' MAX ADD ADDITIONAL USED INTO WOOD PER TABLE 2, SELF -DRILLING SHIM 65 ASSCREWS@ FROM 6316' SHEET 2. ALL WOOD BUCKS LESS SMS (G5). SEE 30 THAN 1-1/£ THICK ARE TO BE 90 TABLE 2, SASH CONSIDERED 1X INSTALLATIONS. IX SHEET 2. EXTERIOR VISIBLE WOOD BUCKS ARE OPTIONAL IF LIGHT HEIGHT t_ 16 UNIT IS INSTALLED DIRECTLY TO SUBSTRATE. WOOD BLOCKS DEPICTED AS 2X ARE 1.1R' THICK 66 OPT USE EITHER OR GREATER. 1X AND 2X BUCKS 65 LATCH OR (WHEN USED) SHALL BE DESIGNED 2) 1- Si 30 a 64 BOTTOM LOCK. TO PROPERLY TRANSFER LOADS TO FLANGE EOUAIINTERIOR31 TESTED UNIT THE STRUCTURE W000 BUCK WEEP FRAME LOCATION. 8-516' DESIGN AND INSTALLATION IS THE SHOWN FRAMENOTCHESAT80FROMSASHENO. RESPONSIBILITY OF THE ENGINEER SHOWNEACHENOORARCHITECTOFRECORD. Q EXTERIOR g 06 3) VISIBLE LIGHT WIDTH OR HEIGHT INSTALLATIONfl INSTALLATION 67 ALSO REFERRED TO AS DAYLIGHT OPTION 4 v OPTION 4 EQUAL-LEGIBOX 114- MAXSHIM OPENING)MEASURED FROM ANCHORED THROUGH ANCHOREDTHROUGHBEADINGTOOBEADING. FRAME SHOWN I I o n I FRAME INTO METAL FRAME INTO METAL 711 IaHsad By: Dab. Rwlal•n: 27• X 125. . II O`A LYNN A///lam I W7EEPHOLE r NO ANCHORSF Z`..••;C,EPIS •', 'P ieE WICOVER ® REQUIRED IN VISIBLE LIGHT FORMULAS Q :' ' , iT ^ R.d..4 Bl' Osla: R.dslon: 2 57' FROM 36 FLANGE OR EACHEND EQUAL -LEG 58705WIDTH10 FRAME SILLS 6- • J. - ® Daudplim Om- 6y: SASH. BUCK WIDTH .112' tg FIXED LITE: BUCK WIDTH -4.318' -, O:• C( w FLANGE & EQUAL-LEG/BOX FRAMES J ROSOWSKI HEIGHT IEOUAI•LITE) '•. S A1L/O{- :• j 1070 TECHNOLOGY DRIVE flu.:Oalc VERTICAL SECTION B B BUCKHEIGHT/2.3.15116' t• - FL(7R10?. '(` N. VENICE, FL 34275 SINGLE HUNG WINDOW INSTALLATION - NI 05/15/15 941)-460-1600 77 BONA\- Saba/Ma4d• Saals Shaal: OMarinq No. CERT OF AUTH. /29296 SH -5400 NTS 3 OF 12 r7jA:Ly)gy405Ced,PE MD-SH5400-01 P E 0 55705 INSTALLATION DETAILS FOR INTEGRAL FIN & J -CHANNEL FRAMES INSTALLATION OPTION 6 INSTALLATION OPTION 5 ANCHORED THROUGH FRAME INTO ANCHORED THROUGH INTEGRAL FIN INSTALLATION OPTION 52X WOOD FRAME OR BUCKSTRIP. SEE INTO 2X WOOD FRAME OR EMBEDMENT EDGE DISTANCE ANCHORED THROUGH INTEGRAL I•f EMBEDMENT NOTE 2. THIS SHEET. BUCKSTRIP. SEE NOTE 2. THIS SHEET. FIN INTO 2X WOOD FRAME OR a— 114' MAX SHIM SUCK- STRIP. SEE NOTE 2, THIS EDGE DISTANCE 1/4' MAK SHIM 16 SHEET. J•CHANNEL FRAME TYP, ANCHOR TYPE. SASH VISIBLE 17 EMBEDMENT SUBSTRATE, E _ 18 LIGHT WIDTH roDISTANCEPERSUBSTRATE, SHOWN SEE TABLE 2. SHEET 2. r QO 1 SCREW 114' MAX $HOA TVP. ANCHOR TYPE. EMBEDMENERAND SHOWN) _ J 44 T PE VARIES _--. _ 0O EMBEDMENT ES 42 WITH SASH DISTANCE /-- I WEIGHT 54 30 31maDISTANCEPERSUBSTRATE, SUBSTRATE. a a 18 SEE TABLE 3, SHEET 2. EXTERIOR TYP. ANCHOR TYPE. NAIL SHOWN) 87 INTEGRAL EMBEDMENT AND EDGE ID 3 FIN DISTANCE PER FIXED VISIBLE FIXED 19 VISIBLE 20 OPT. SASH TOP LIFT RAIL FRAME SEE TAB E 3. SHEET 2RATE, J LIGHT WIDTHLO SHOWN (NAIL SHOWN) LIGHT f " c' HEIGHT I FOR ALL WINDOWS. FRAME NOTES SHOWN 18 1 ANCHOR ® 3 55' BUCK MOTH 1)USE ONLY49FROMENOANDAT HORIZONTAL SECTION C -C a 21 CENTER. 22 FOR WINDOWS SUBSTRATE -APPROPRIATE ANCHORS LISTED ON TABLES 2 & 3OI 73 1 OVER 36' WIDE' OF SHEET 2. FOLLOW EMBEDMENT 114. MAX DADE APPROVED MULLION, FOC COMPLIANT ALUMINUMISTEEL FRAMING OR STEEL STUD. 0 ADO ADDITIONAL 5 48 17 SCREWS ®16-3/&' AND EDGE DISTANCE LIMITS. ANY MAY BE VERTICAL OR HORIZONTAL. SEE SUBSTRATE PROPERTIES TABLES 2 & 3 SHEET 2. INSTALLATION OPTION SHOWN MAY SHIM 14 35 FROM ENO. BE USED ON ANY SIDE OF THE BUCK V FOR WINOOWS WITH WINDOW. - HEIGHT 50 a O BOTTOM LOCKS. 16 ADD ADDITIONAL N10 OR N12 STEEL _,..( 114- MAX 2) MASONRY ANCHORS MAY BE SELF•DRILLING SHIM SCREWS ® 6.3/8' USED INTO WOOD AS PER TABLE 2, SMS (G5), SEE I BS 30 1 SASH FROM END SHEET 2 ALL WOOD BUCKS LESS TABLES 2 6 3. THAN 1.12' THICK ARESHEET 2. n EXTERIOR VISIBLE CONSIDERED 1X INSTALLATIONS. ONS. U1XW000BUCKSAREOPTIONALIF LIGHT HEIGHT USE EITHER UNIT IS INSTALLED DIRECTLY TO 86 L_ OPT LATCH (SHOWN) 16 OR BOTTOM LOCK (SHEET 31. SUBSTRATE. WOOD BUCKS DEPICTED AS 2X ARE 1.12' THICK n OR GREATER. 1 X AND 2X BUCKS l Q 2) 1- 81 30 65 TESTED UNIT63 WHEN USED) SHAH BE DESIGNED FIN AND/OR aTOPROPERLYTRANSFERLOADSQINTERIOR31LOCATION. 6.518' FLANGE REMOVED WEEP FROM SASH ENO. TO THE STRUCTURE. WOOD BUCK IN•FIELO NOTCHES ATDESIGN80Q AND INSTALLATION IS THE RESPONSIBILITY OF THE ENGINEER INTEGRAL FIN EACH ENO. NO ANCHORS OR ARCHITECT OF RECORD. FRAME SHOWN 7 REQUIRED IN FRAME SILLS IF ANCHORING 3) VISIBLE LIGHT WIDTH OR HEIGHT INSTALLATION EXTERIOR INSTALLATION THROUGH FRAME. ALSO REFERRED TO AS DAYLIGHT OPTION 7 OPTION 8 114' OPENING) MPJ( IS MEASURED FROM ANCHORED THROUGH FRAME INTOANCHOREDTHROUGH INTEGML FIN SHIM SHIM BEADING TO BEADING METAL (INTEGRAL FINIFUWGE REMOVED) INTEGRAL FIN INTO METAL FRAME SHOWN 2OWICOVREQ Raded BY. Dab: Rwhbn: IYNN 4/i4e382 67E' UN`I 9FEF FROM EACH ENO — VISIBLE LIGHT a .•''`\CEIJSF R°.Naad By: 0°b: R°Hsba, FORMULAS TYP. ANCHOR TYPE, 140. 50705 ' EMBEDMENT AND EDGE — EDGE DISTANCE WIDTH DISTANCE PER SUBSTRATE. — @SASH: BUCK WIDTH .6-112"b: SEE TABLE 3, SHEET2 --I EMBEOMENT SCREW SHOWN) 1 FIXED LITE: BUCK WIDTH -4.378' -•p : '" t;J-CHANNEL & INTEGRAL FIN FRAMES J ROSOWSKI f.1Si^IC(F/tiHEIGHTEQUAL -LITE) O BIN:Dat°• 05/15//15PTION5VERTICALSECTIOND -D BUCKHEIGHT2-3.15/16' ''%;;/ DORALORIL.= ` SINGE HUNG WINDOW. 1; INSTASTRIP. nNCINTO2%LoT oOucHWOOD Scoff:hINSTALLATIoONo No. Re., ra 10iNTOEGRAININ A7.Lkm MILI R,PE. SH -5400 NTS 4 OF 12 SH5400-01SEENOTE2, THIS SHEET. P E 0,68705 CERT. OF RUTH. 129296 714' NOM. — 314' NOM 3/4' NOM. 3/4' NOM. +-- I I 1/8" A GLASS - 1/8"T GLASS 1/2" AIR SPACE 3116"A GLASS - 3116'T GLASS 1/2" AIR SPACE 1/8" A GLASS 1/8 T GLASS3/16" 3/8" AIR SPACE A GLASS 3/8" AIR SPACE — \ T GLASS c] EXTERIOR EXTERIOR a EXTERIOR a y EXTERIOR DURASEAL, DURASEAL, DURASEAL, DURASEAL, SUPERSPACER + SUPERSPACER— SUPERSPACER-- SUPERSPACER OR CARDINAL SPACER OR CARDINAL SPACER OR CARDINAL SPACER OR CARDINAL SPACER GLASS TYPE 1 GLASS TYPE 2 GLASS TYPE 3 GLASS TYPE 4 1/2' NOM.GLASS 76 OR 77 OR 78 BITE TYP. 31 pEMERIORII 75 tlll J8 30 Q 111111111111 pN•........ 4112 By. D.C.: R.w.bn: TYP. GLAZING DETAIL No. 58705 Y` R.vl..d W. 0.1.: n LC - nT' s L•l= o"Cdpllon: om— W. GLAZING DETAILS J ROSOWSKISIALl:' l J; Fl 1-'\C 1070 Fluc Oct.. ANNEAL R. 7 N y411 VENI eo SINGLE HUNG WINDOW INSTALLATION - NI 05/15/15 TEU. 111111111 boo Sado/Yedk SCa/c Sk.d: do.Mp No. R.v: A. LYNN MILLER. PE. 5117PE.11 SE105 CERT. OF AM. 129298 SH -5400 NTS 5 OF 12 MD-SH5400-01 Gl qe e... 7.. 4.t-O..h Mdy1nr0. 041.1pn Plefabte trolT7) WI•d-Nd Wld,htln) M. PQ It 1 14 11 a1 0 48 1 1035 Eµnllr II00I •030 1400 400-1000 w0 1000 1 q0 IWO 1 000 1 IWO 000 100 w0 170 IrroYe/ MYN 11611 IIIA •w0 I=a Na• 1000 00 4010 1 we IWO 000 IWO w0 410 000 100 A E.W Or 1100 I.fN .000 4000 4500 1009 q0 We 1 000 two w0 1000 4600 1000 4.0 41.1 Slwd, q F..Yw 11 711-041 •000 1400 000 1090 000 IN 4000 1000 100 two 000 IWO 300 m0 TMY. 1 11611.7174. •100 1000 4.0 1 1000 000-1W0 000 4W0 000 4W 600 440 w0 211 N.• Old CM117r A014-71610 .me Iwo 000 1 IN Me 1000 0060 a tl0 4140 q0 m 400 101 11114 C-1 M. 9 11411. 5411 Imo IWO q0 1 1400 we we We- 100 WO 1m0 000 110 4"a 4140 WFM. a 14611.11110 .We 1030 400 I 1400 we 1w0 410 1400 400 loco 4300 111 300 141 Olon.. l 11)1/•11616 .No moo 500 1 1000 we 1000 000 1000 tl0 1000 tl0 110 000 Ile I. IY•1 1/-.11011 •500 We q0 1400 Owe 1000 w0 4/0 000 100 100 140 600 110 Cu10n 61r 5411 -]I- •We IWa 100 IWa 400 1000 N. Iwo Roo Iwo mo 171 1 w0 Ile f11m0d 6YII.6r 71411.565 .000 100 No 1400 q0 1000 rWe two we 1000 Ia0 t10 we 100 44 Eµ.d M. Afll. (1111 .q0 1000 000 IWe WO NO wO 1000 000 100 549 141 0500 101 61e. alalFKw no's .100 1000 000 We WO 1000 000 1000 00.0 1000 w0 144 NO 104 1. 1.14.{4. 1101/-1165 .000 1030 000 100 q0 1000 q0 loco IWO IWo we 5. w0 117 Ilalr. l 117//-II{l0 .w0 1000 7000 71000 000 1030 030 4000 000 MI tl0 146 000 1110 IrIY. I IIW•73311 .000 000 Me We 000 no we 493 we wl 409 110 410 411 otr•. W Cally Me.,- or .w0 1000 WO 71000 410 4000 000 Iw0 1 000 III WO 110 w0 131 ENIN A011•A1t0 •000 1000 w lw0 44.0 loco 000 4WO 400 917 400 416 100 470 41 61.61161 FMw. 1/41/•ANo •4.0 mo pe two No 1000 lao 1000 4tlo 571 60 711 po aro Wlea iY. 1161/.1165 744 1000 rwe Iwo q0 4000 4600 IWO 00 4.o 410 Ha we wl 9 W1m1{ br 141/•1111/ •qe 4(000 WO 1000 tl0 two 400 w/ q0 4/o q0 116 410 441 11) 11. 11 sm •AO Im0 500 4000 w0 4.0 4400 001 a 451 600 721 600 413 IIMI 11700.316.16 .foo 1000 030 451 4410 115 6110 421 000 411 No 111 w0 III ILr. YIe GI.pr 5{1r•u", .600 nmo Iwo Iwo 100 Iwo w0 1000 600 161 00 11.1 1300 411 uEµ614. 71511•Aelf .w0 1000 600 4WD 600 1400 300 4030 600 011 600 lie We 431 Io 61e WNa 3b. 561/•21114 •000 two 0 IWa 0 IN. a IN. we 016 No I a w f10.YgFKw IIIII.A610 •300 1000 000 me w0 me 000 1m0 We 4.0 we 437 w0 466 lu1ra 14. 14011.17016 •000 1000 600 1100 No we we 4e0 rNo 006 000 764 w0 411 Cu1u.6b. 1711/•1445 •4.0 1000 No we WO 131 00 424 4.0 437 600 727 400 411 Mul 113/ 1.11616 .000 1000 w0 4oi we 00I 000 1/0 WO 410 w0 4 4 w0 611 1.1Ytl 31117-41614 •pe Iw0 we 420 w0 itI w0 006 We 411 000 m1 000 007 1.,.nroC. 11r0• 1.61/.144.0 .WO IWo WO 1 IWO 001 4.0 401 600 414 wf M2 we as IF--. 56. 1•111.4 •410 two 4300 1400 rq0 1000 4.o wI 4.o 4$1 4.o r- 41.7 We Ml fIM1NFKr 71611. 71611 4W0 1000 4.0 w/ w0 411 x400 MO 000 41 10W 464 We 416 47 CuNm BY1 5111•}4414 -we tooa 00 401 We Ire wo d44 4.o 411 w0 411 000 110 CuYmfY. 11411. 5616 .4.0 411 4.o 104 WO w/ we 431 1 617 000 we 000 416 4u11rm ib. II11/•11610 •410 4.o tl0 130 w0 4.e 000 400 600 570 6100 450 w0 416 CuW.6b. 10011.11410 •4.0 al 4.e 00 W. JIO 7000 400 too 411 4.0 421 000 416 s_0 114.1.1101. -We 401 We 416 300 410 500 439 tl0 411 000 400 We 000 I.h41 561/•41 M1 .No IWO We 41• rWe 617 We 466 0 11.1 000 wf WO 410 Cu11rI.Nw 31UI.54N .ma Iwo w. w/ mo 176 w0 140 w0 I41 1". wl 40o wl 6wIM. 31411. 31474 .No 1000 we Qo 43(34 404 we NI 4600 5e No we we 42. 16 CubnOY. r41/.31410 •we 1000 We 001 7000 7.0 4.o 711 4.o 002 we 002 w0 424 N dr41FKa 5611.11416 .4.e 416 4.e 750 4.o ai WO wl WO 414 1004 442 400 410 CuWn fb. 1.5616 .000 412 000 Ile 4.0 001 410 001 we 411 030 43 600 4 64 0 21{10.50- .300 000 No 410 4.o wl 000 460 000 410 000 411 two 001 EµeWl. 31611. 11- .4.e Nf 4.0 1/{ Iwo wl 4.0 wl W0 416 400 001 600 wf N Culem lb 500.5610 .4.o 41.7 000 110 4000 000 000 001 w0 111 000 411 tl0 001 10.0.00n0µ4 31461.31511 .4.e 411 rw0 416 030 110 400 we we 411 4.o wo 1tl0 400 11.10 ece r. e. 61. 0.1 c 41611 .00 431 00 41- 000 410 4.0 411 4409 SU 00 We W0 we 6, SHEET 6 FOR ANCHOR GROUP AND OUANTITY. NOTES: 1) USE THIS TABLE FOR ALL WINDOWS INSTALLED THROUGH THE FRAME OR INTEGRAL FIN. 21 FRAME DIMENSIONS ARE BUCK. SASH HEIGHT IS AS PER THE FIGURE. 3) FOR SIZES NOT SHOWN. ROUND UP TO THE NEXT AVAILABLE WIDTH OR HEIGHT DIMENSION SHOWN ON THE TABLE. 11 or EM7 ••. T No 50705 L bTAIL' or 4(/- 01110 I YrY SA: LYNN MI( ER, P E. P E 0 58705 JAMB SECTION DETAIL FOR WINDOWS WITH LEVEL R1 REINFORCEMENT & GLASS TYPES 1-4 REINFORCEMENTS SHOWN IN FIGURES ABOVE APPLY TO ALL FRAME TYPES 6 CONFIGURATIONS) H iT rI45. Ory: . 140. 1: R.Webn: R.Wofd Sy. Oat.: RwI.Im 040vot/en: Orono BY: DESIGN PRESSURE TABLE J ROSOWSKI 1070 TECHNOLOGY DRIVE ItUc Dote: N. VENICE, FL 34273 SINGLE HUNG WINDOW INSTALLATION - NI 05/15/15 941)-460-1600 SWeelMedd. SeaN: Shat: Orbnlnp He- Rev. CERT. OF AUTH. /29296 SH -5400 NTS 6 OF 12 MD-SH5400-01 TABLE 5: 161.; ry.. 411L,.6..0 13.0093.30 y,w ro 16..0N4dI4 9161930 pNflurl (109m 1Nnw.00d vna16130 1 alMl'.v.l 136 t". N. I6 111. -no lao 2. 1{SO Ine It YO T 1300 Nµ0 1300 rw0 I30o ot630 sl us 00 G0.w6Gm/. Hur.11ono ,we 1300 wo Ina 100 30309 040 1330•we I300 wo mo 4100 IsEO.i4. 1IW.I.ON •ISO r Ino Nf0 1300 e Ia1 00•1300 VO 1300 4040 Ivo1300 YoVO 7uoe1N.q /1..w I11.11 Y] ..e 1300 YO 7300 0 1300 UO 1300 KO 4100 as 1300 I 0 I 1300I.ou.n u.r•437r .Uo Ino 630 tae U0 13030 NSo 1.9 Us 1309roo I30o as1.g.,a all./. 306ri•aG6 I.o 300130 o I a Y tae I.o 7309 we 30300 roo u.. 00 113971113r316Eyre• vur•ri43I .uo 309 uo Ino wo Ine 109 73030 e 30309 430 Ixl} weal.ylq ml,3. 14 ur. a6w ..0 Ino o I30o wo T. we I30o e IJoe we 10,3 v.wN nall •14Ole .00 1300 N)e 1 Imo no 430o Ya 1300 tlo 1127 w0 1107 ui3n K31 w1 Iwo No wo 1300 YO dao IKo a Yo 1300 00 wo 3006 w/ ton CYlM C11. ri11f.}1047 ,YO 1300 µ0 1300 ro Ino 10)9 1300 e uae w0 No e 4130 f4q.q CN4P x1111.7/.{ •600 1300 0 1300 YO 1300 no 1300 1430 1300 111} w.0 W4 J1 FOs14. 10111 - Jam Iwo 1300 1070 1300 430 Ino 0 1300 U0 1300 UO 110/ 0 N7 161Y.q A.N.w 11.01/•1001f I.0 1300 w0 1300 430 1300 U0 1300 1/se 1000 Ve M4 G.I.n G1. 11111.1111. .UO 1300 o 1300 430 1300 0 1300 0 Ia0 UO 1100 0 N. W-1- 6b4.1 I. 111.11110 •KO 1300 f30 Me 430 1.0 040 111.3 UO INYI 11 W•nG1 ..o 1300 we 1300 1300 wer0 We712 eUO Ino1101 00w0 1300 1100 0no 4011Ne 010650 1017410G.N.ga.l.rp 7/01!•11042 •w0 Ia0 1300 430 1300 430 Ino Us I30o 040 Id3 µ0 N.1EOYIN. 30111.10610 ,.0 1300 y0 1300 YO A e I30o µ0 No 0 41002 K0 N6116loWdrpy., 17I11.30IY ,w0 1300 me 1300 YO 1. Ye 1300 00 1300 0 1.0 UO N/ Won i4. I.1l 111 1070 1300 070 1300 YO 1300 NO 1300 YO 1300 1030 Ir6C.09.30.1. 1101I•G116 .no 1300 0 InO Is 1100 UO Iwo 0 1300 V. 1100 430 NIfIWN111/1.1301{ •UO 1300 0 Ino IYO IWO we 1300 0 1130 630 1110 160 1010 j M.xie l me •.0 Ino I.0 1300 YO 1160 UO 1111 w0 1111 y0 NO w0 4101.1WNCtl30. ri111•n 301 .KO 1300 wo 1300 YO 30.0 w0 1300 0 MA w0 NI w0 NICEw1.M. 11111•30K0 .KO 1300 YO u00 NO Ina NO 1300 UO 1300 w0 101/ UO 011911xCullenll. 30011.77610 •YO 1300 MO 1100 YO 1300 YO 1a0 0 1300 IKO 1020 0 417161010.10 Rw1.w 1r tlT-306w 100 1300 we me 9 1100 we 1300 IUO 1300 YO IwI is InCu4n4. 11011.11010 •we 4300 0 I30o 430 1300 VO 1300 We In -0r. U0 Ir. y 419Cu.l ou. 1111.1..10 •w0 Ino I Ino 1 110 Ino UO 1391 1030 170{ U0 ImI 170 416.11..1 uur•11Y ..e 7300 o I30o 1142 a 1130 0 1130 U0 Iso 1.13.1 030111.41.. Ine 130 6. 430 NT 1430 N9 no 410 YO u2} 411 0 1044 i4N4NCNI.P 11011.30110 •.e 1300 Us Ino 0 1 w4300 1x11 µ0 1}10 UO 400 ISO 411EpOIw. riftr•JION .UO 1306 VO 1300 IYO 130010/ Ime 161 1191 w0 J17 GOeq..ew nw•10.. .Ke 1100 430 4300 43 m1 143 1304 o N7 y0 100 u C -so. 10e11•r3w ..o 1100 wo m1 IYo Im9 No wo 1 0 411 0 410 C _so. IIA" m's N a 1100 1119 o As 1..1 M. wo 43. uo 414 CI.N n G1. 1111/•11110 ,U9 1734 0 0 AT, UO 9 w0 NS 0 410 WI.n4Y. Il oil •1. IN ,.0 1306 1030 Im7400 YO Nt 400 414 w0 100 w0 Ifx I.0 367 IM.9 110G•110N ..0 1111 Iµ0 N0 U0 YO4fI 101Iwo UO404 w0 Ue106 4160 e 434 400 659 w9 114 400 i...l 31111..1.4 •430 1300 9 IIIe INe 101 O 410 0 we 63 411 1.I 317 G.11.0 a.. Yur•a6N .Ye 1300 o 1717 U9 7041 we Imo 439 Jwr a 419 ue 301 EHIY. 4311/-Y 6. •YO 7300 we 111 Ne 7111 1010 IPI Yo Imo wo 4.0 no 131 NC1,fso. 1l011•UII. ..0 1300 w0 110.6 430 NII we M/ 166.0 YS 0 M] y0 J1 s4 NMw 79011.10610 1010 Ib0 w0 Im1 no RI U6 NI y.9 101 UO 437 160 411 Ou1.0. G1. ri{I1.ri011 •w0 1301 w0 N3 040 410 ue r1i 1.0 19/ YO 0 441 ib4..1 161.•10011 ..0 7.1 Ue 400 me Z41. I.0 Ill UO 44} 430 1.. EpIN. r.r-N w. roo 30o o 104/ we 4}6 no 411 ale 463 0 I/9 416KO Iwo119 YWg30.0 n6lr•YfN •wo 130.1 1U0 NS r0 040 w0 J0/ CSO 109 10)0 Jo. 4330 m. a.103003. uw•u431 .00 rm. 1 .w .Ue 111.1 o 49 o it. 43o 41. We 316 no Ne toe 0 Ko 111 300 SEE TABLE ur1 7. SHE FT 0 MIT 4a1f`uno r_on110 ....30 ...........• 430 4.4 Uo 101 wo 41. 439 r:6 150 4oe wo roo NOTES USE THIS TABLE FOR ALL WINDOWS INSTALLED THROUGH THE FRAME OR INTEGRAL FIN. 2) FRAME DIMENSIONS ARE BUCK. SASH HEIGHT IS AS PER THE FIGURE. 3) FOR SIZES NOT SHOWN, ROUND UP TO THE NEXT AVAILABLE WIDTH OR HEIGHT DIMENSION SHOWN ON THE TABLE. LYNN df/ 'I, 'S,, EN 140 58705 C •., s r rc of TTS UfVAI. 00" A. 4klm P.E JAMB SECTION DETAIL FOR WINDOWS WITH LEVEL R2 REINFORCEMENT & GLASS TYPES 2.4 REINFORCEMENTS SHOWN IN FIGURES ABOVE APPLY TO ALL FRAME TYPES 6 CONFIGURATIONS) H 1T 77- 1 0130030 By. DESIGN PRESSURE TABLE J ROSOWSKI 1070 TECHNOLOGY DRIVE nos: pep; N. VENICE. FL 34275 SINGLE HUNG WINDOW INSTALLATION - NI 05/15/15 941)- 80-1600 So/ w/es"ok Scar.: SMd: poldnp 100. R r. CERT. OF AVIV. /29296 SH -5400 NTS 7 OF 12 -mg No. 400- 01 3.500' 062' L L 625• J•CHANNEL FRAME •625' 1.315' (DIIMIJAMB 3.483• --i 4- 662• 4, ju 1 2,.{- JO 01 625' O 5 J•CH/V1NEl1.375 FRAME SILL 1 625' T- 1483" 0 OFLANGE FRAME HEADIJAMB 3.463• --I 062• D - 0 2 {.{• U 01 OFLANGE FRAME SILL 3.483' 0 -..- . 662• fl 2.{{{- D o OFIN FRAME SILL 7.500' I-- .062' lu C-7:1 D 1463' L- 10 L OEQUAL LEG FRAME HEAO/JAMB 0266- 1 165• JJJJI OLIGHT SASH 23 REINFORCEMENT i070• T, 3.46T I RMf.d By 062• D - 1.o r 0 Dob: p U 1 T., 1.331• ,- L .130• H 1.340' - ey. J ROSOWSKI 1070 TECHNOLOGY DRIVE N. VENICE. FL 34275 9{1)-480-1600 RRa SINGLE HUNG WINDOW INSTALLATION - NI 0fLio1 OEQUALLED FRAME SILL NTS 0266- 1 165• JJJJI OLIGHT SASH 23 REINFORCEMENT i070• T, 1.1• 82- - o RMf.d By o7a To .036' 1.o r R.Wad B/. Dob: p U 1 T., 1.331• ,- L .130• H 1.340' - STANDARDHO MEETING RAIL26MEETINGRAIL27REINFORCEMENT REINFORCEMENT 1 1.072• --{ r- 1.0{1' 11 1 215' _ 2.100•( 1 {72' 1.565' 1. 630wa --{ 1376 1 2.11605• .065' -- - 1.375' I, TSI o a I 1 035' . 590• Ij- j0 J .050• . 471• IVR 7j'j(l Ir u 1 'f .J/7' 1 Ow 355 0 . 070' J 59a J XE ILx3rE•.- -.- l.aoa f-- 010• .oso• FI14MEETING RAIL 16 SASH RAIL 17 COVER 1B SCREW COSASH P 1B INTERLOCK t0 LIFT RAIL LIFT RAIL 21 BEVELED 22 BEVELEDINTERLOCKCOVEROINTERLOCKOINTERLOCK COVER I . e64 316 - tt .300* -- 1__L301• 1_L 75t•' .750' O 035 --a- ozs --tF- 73 IG BEAD e1 EXTRUDED OROLLED SCREEN FRAME 82 SCREENFRAME 7') g'i LYNN 4lt''' 'A7 1JCENgF lti : • No 50705 •'• }: U lGZ- G = O I C STAICo GV p • <oRloP..•'.; r S/1^J.%(/•••,•-L J( rA'4rPE/56;05 FE o RMf.d By We. R.Wad B/. Dob: R.W.1": WINDOW EXTRUSIONS ey. J ROSOWSKI 1070 TECHNOLOGY DRIVE N. VENICE. FL 34275 9{1)-480-1600 RRa SINGLE HUNG WINDOW INSTALLATION - NI Ofba 05/15/15 S.A../Mod.h Scoff: SH -5400 NTS Sh..l: 10 OF 12 Of -N No. MD SH5400-01 R.r. CERT. OF AOTH. 129296 NOTES, 1) SOME PARTSIOPTIONS NOT SHOWN ON DRAWING FOR CLMIIY. 2) J•CHANNEL FRAME SHOWN, PMTS / 1 6 5. OTHER FRAME TYPES APPLY. J) FOR REINFORCEMENT TYPES, SEE DETAILS ON SHEETS 0 6 7. A) USE EITIIER SASH TOP LOCKS OR SASH BOTTOM LOCKS. p.• IICENSC •. lF '. No. 0705 Al v0 i lCs \ L 0.I. R, P.E. P E 15!705 MITERED FRAME HATH INTERIOR AND EXTERIOR FRAME WELDS I CERT. OF AM. /29295 I SH -5400 I NTS 112 OF 12 I MD-SH5400-01 I Prdfe01bn• o A 1Fia'da C r partmenvf BCIS Home : Log In User Registration Hot Topics I Submit Surcharge Stats & Facts 1 Publications FBC Staff j SCIS Site Map Links Search Busines9 a) ProfessI*USER: Product Approval Public User Regulation Product Approval Menu > Product or Application Search > Application List > Application Detail FL # 1`1261-119 Application Type Affirmation Code Version 2014 Application Status Approved Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission If necessary. Comments Archived Product Manufacturer PGT Industries Address/Phone/Email 1070 Technology Drive North Venice, FL 34275 941)486-0100 Ext 22318 druark@pgtindustries.com Authorized Signature Jens Rosowski jrosowski@pgtindustries.com Technical Representative Jens Rosowski Address/Phone/Email 1070 Technology Drive Nokomis, FL 34275 941) 486-0100 Ext 21140 jrosowski@pgtindustries.com Quality Assurance Representative Address/Phone/Email Category windows Subcategory Mullions Compliance Method Certification Mark or Listing Certification Agency Miami -Dade BCCO - CER Validated By Miami -Dade BCCO - VAL Referenced Standard and Year (of Standard) Standard Year TAS 201, 202, 203 1994 TAS 202 1994 Equivalence of Product Standards Certified By I affirm that there are no changes In the new Florida Building Code which affect my product(s) and my product(s) are in compliance with the new Florida Building Code. Documentation from approved Evaluation or Validation Entity .-' Yes No N/A Product Approval Method Method 1 Option A Date Submitted 06/29/2015 Date Validated 06/29/2015 Date Pending FBC Approval Date Approved 07/05/2015 Summary of Products FL # Model, Number or Name Description 261.1 Mullions for All Doors and Windows Aluminum/Vinyl Mullions Limits of Use Certification Agency Certificate Approved for use In HVHZ: Yes FL261 R9 C CAC 14-1105.01.0df Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: Yes 05/26/2016 Design Pressure: N/A Installation Instructions Other. Please see Miami -Dade County Notice of Acceptance F1.2fii R9 U 14-1105,01_odf NOA) for product performance information, and mullion clip Verified By: Miami -Dade BCCO - CER anchorage details. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: Back Next Contact us :: 1940 NeRh Menree ctre.t_ 7allaha F '129oa Phone_ 850.487-1824 The State of Florida Is an AA/EED employer. Coovdaht 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, emall addresses are public records. If you do not want your e-mail address released In response to a public -records request, do not send decbonlc mall to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please cor>ted 150.487.1395. •purmant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Deparbnent with an email address It they have one. The ernalls provided may be used for official communication with the licensee. However email addresses are public reox If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public To determine If you are a 11mese under Chapter 455, F.S., please didt b=. Product Approval Accepts: 0® Credit r'a1 SAFE M IAM I•DADE DIIA11II—DADE COUNTY, FLORIDA PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADiMINiSTRATION DIVISION T(786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.eov/economy PGT Industries, Inc. 1070 Technology Drive North Venice, Fl. 34275 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami—Dade County RER— Product Control Section to be used in Miami—Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami—Dade County Product Control Section (In Miami—Dade County) and/ or the AHJ (in areas other than Miami—Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may, immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami—Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone. DESCRIPTION: Series "PGT" Clipped Extruded Aluminum Tube Mullion —L.M.I. APPROVAL DOCUMENT: Drawing No. 6300JR, tilled "Impact—Resistant Aluminum Tube Mullions", sheets 01 through 25 of 25, prepared by manufacturer, dated 08/29/1 lwith the latest revision dated 01/29/15, signed, sealed and by Anthony Lynn Miller, P. E., bearing the Miami—Dade County Product Control Revision Section stamp with the Notice of Acceptance number and Expiration (late by the Miami—Dade County Product Control Section. AUSSILE IMPACT RATING: Large and Small Missile Impact Resistant LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state, series, and following statement: "Miami—Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or ahangc in the materials, use, and/ or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami—Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA No. 13-0815.05 and consists of this page I and evidence pages E-1 and E-2, as well as approval document mentioned above. The submitted documentation was reviewed by Jaime D. Gascon, P. E. NOA No. 14-110301 Expiration Date: May 26, 2016 Approval Date: February 12, 2015 2`ti ls Page PGT Industries, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED A. DRAWINGS 1. Manufacturer's die drawings and sections. Submitted under previous NOA No. 10-0819.05) 2.- Drawing No. 63003R, titled "Impact -Resistant Aluminum Tube Mullions", sheets 01 through 25 of 25, prepared by manufacturer, dated 08/29/11 with the latest revision dated 01/29/15, signed, sealed and by Anthony Lynn Miller, P. E. B. TEST_ S 1. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202-94 2) Uniform Static Air Pressure Test, Loading per FBC, TAS 202-94 3) Water Resistance Test, per FBC, TAS 202-94 4) Large Missile Impact Test per FBC, TAS 201-94 5) Cyclic Wind Pressure Loading per FBC, TAS 203-94 6) Forced Entry Test, per FBC 2411.3.2.1, and TAS 202-94 along with marked -up drawings and installation diagram of clipped aluminum mullions, prepared by Fenestration Testing Lab, Inc., Test Report No. FTL 6443 samples A-1 thru E-1), dated 02/28/11, and addendum letter dated 05/05/11, signed and sealed by Marlin D. Brinson, P. E. Submitted !ruder previous NOA No. 10-0819.05) C. CALCULATIONS 1. Anchor verification calculations and structural analysis, complying with FBC 2010 and with FBC 51h Edition (2014), prepared by manufacturer, dated 01/29/15, signed and sealed by Anthony Lynn Miller, P. E. D. QUALITY ASSURANCE 1. Miami -Dade Department of Regulatory and Economic Resources (RER). E. MATERIAL CERTIFICATIONS 1. None. F. STATEMENTS 1. Statement letter of no financial interest, conformance to and complying with the FBC 51h Edition (2014), dated 11/03/14, signed and sealed by Anthony Lynn Miller, P. E. 2. Statement letter of no financial interest, conformance to and complying with the FBC2010, dated 06/06/11, signed and sealed by Anthony Lynn Miller, P. E. 3. Proposal issued by Product Control to PGT Industries, Inc., dated 08/06/14, signed by Jaime D. Gascon, P. E., Product Control Section Supervisor. ai»re D. Gasco P. E. Product Control Section Supervisor NOA No. 14-1105.01 Expiration Date: May 26, 2016 Approval Date: February 12, 2015 E—] PGT Industries, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED F. STATEIVIE NTS (CONTINUED) 4. Laboratory addendum letter for Test Report No. ITI,6443, issued by Fenestration Testing Lab, Inc., dated 05/05/11, signed and sealed by Marlin D. Brinson, P. E. Submitted raider previous NOA No. 11-0922.01) 5. Laboratory compliance letter for Test Report No. FTL-6443, issued by Fenestration Testing Lab, Inc., dated 02/28/11, signed and sealed by Marlin D. Brinson, P. E. Sttbnritted under previous NOA No. 11-0922.01) 6. Proposal No. 10-1070—R issued by BNC to PGT Industries, Inc., dated 01/07/11, signed by Ishaq I. Chanda, P. E., Product Control Examiner. Sttbnritted under previous NOA No. 11-0922.01) G. OTHERS 1. Notice of Acceptance No. 13-0815.05, issued to PGT Industries, Inc. for their "PGT Series Aluminum Clippcd Mullion — L.M.I.", approved on 11/31/13 and expiring on 05/26/16. 1- OG ` 1_'Y- - Jain e D. Gascon, P. E. Product Control Section Supervisor NOA No. 14-1105.01 Expiration Date: May 26, 2016 Approval Date: February ]2, 2015 E-2 SUITABLE FOR ALL LOCATIONS REOUIRING NON -IMPACT OR LARGE AND SMALL MISSILE IMPACT -RESISTANT PRODUCTS FIGURE 1: MULTIPLE [—OPENINGYA OTHFORVEIITICAL"ILL. MULLIONS / " SEE OETAIL IRO,C,K SIEETS 2J SEE OETALLS i / C I11 I A TNRUG; SNEET52-31- I _ II / III / II VERT. MUNILENGTH 1 /4 SEE OE TAILS NORZONTAL A O.Gx MULL SHEETS 2J LENGTH HORIZONTALMILLLENGTH GENERAL NOTES' 1) DETAILS SHOWN ARE FOR THE MULLION ONLY. ANCHORS SHOWN ARE IN ADDITION TO ANY ANCHORS REQUIRED FOR THE FENESTRATION PRODUCT INSTALLATION. TYPICAL APPLICATIONS ARE SHOWN. EACH SITUATION IS UNIQUE AND SHOULD BE EVALUATED BY AN EXPERIENCED INSTALLER FOR THE BEST INSTALLATION METHOD OPTIONAL 1X OR 2X WOOD BUCKS IF USED, MUST BE ANCHORED PROPERLY TO TRANSFER LOADS AND ARE TO BE DESIGNED BY OTHERS. ARCHES TOPE 2) THE TYPE AND NUMBER OF ANCHORS IS CRITICAL TO THE STRUCTURAL PERFORMANCE OF THE MULLED UNITS MULLIONS INSCRIBED wS10E HAVE BEEN TESTED AS'FREE-FLOATING' AND DO NOT NEED TO BE DIRECTLY ATTACHED TO THE MULLION CLIPS, BUT SHALL RECTANGuIAR NOT HAVE A GAP OF MORE THAN 1/6' FROM THE CUP, SHAPE 3) THE ANCHORAGE METHODS SHOWN HAVE BEEN DESIGNED TO RESIST THE WINDLOADS CORRESPONDING TO THE REQUIRED DESIGN PRESSURE. MULLIONS ARE CALCULATED TO DEFLECT NO MORE THAN UI60. THE 113 STRESS INCREASE WAS NOT USED IN THIS ANCHOR EVALUATION. THE 16 LOAD DURATION FACTOR WAS USED FOR THE EVALUATION OF WOOD SCREWS 4) PROPER SEALING OF ENTIRE ASSEMBLY IS THE RESPONSIBILITY OF OTHERS AND IS BEYOND THE SCOPE OF THESE INSTRUCTIONS. 5) USE THE COMBINED WIDTH OR HEIGHT OF ONLY TWO ADJACENT FENESTRATION PRODUCTS TO DETERMINE PRESSURES AND 1 SEE DETAILS ANCHORAGE FOR THE COMMON MULLION, SEE EXAMPLES ON THIS SHEET AND SHEET 24. FOR MULTIPLE UNITS, CONSIDER A THR/ IEET c, ONLY TWO ADJACENT UNITS AT A TIME WHEN USING THE DESIGN PRESSURE AND ANCHORAGE TABLES. THE LOWEST DESIGN OP SIIEErs PRESSURE OF MULTIPLE MULLIONS OR FENESTRATION PRODUCTS SHALL APPLY. ENINGHEIGHT 6) WHEN FINDING YOUR SIZE IN THE MULLION TABLES, ALWAYS ROUND UP TO THE NEXT SIZE SHOWN ON THE TABLE(S) FORIIONZONTAL SEE DErAIL E, MULL 7) ANCHOR EMBEDMENT TO BASE MATERIAL SHALL BE BEYOND WALL DRESSING OR STUCCO. WOOD BUCKS BY OTHERS, MUST SHEETS BE ANCHORED PROPERLY TO TRANSFER LOADS TO THE STRUCTURE. ANCHORS SHALL BE COATED OR CORROSION RESISTANT AS APPROPRIATE FOR SUBSTRATE MATERIAL. DISSIMILAR MATERIALS SWILL BE PROTECTED AS REOUIREO TO PREVENT REACTIONS. FENESTRATION 6) REFERENCE: TEST REPORTS: FTL-6443: ELCO ULTRACON/AGGRE-GATOR NONS; ANSUAFSPA NOS FOR WOOD CONSTRUCTION; PRODUCTSALAY AOM -ALUMINUM DESIGN MANUAL OE OF AM' TYPE. MUSTMANUFBE B) MULLIONS AND CLIPS HAVE BEEN DESIGNED & TESTED TO COMPLY WITH THE REQUIREMENTS OF THE FLORIDA BUILDING GYPGTAY PGf. CODE, AND ARE APPROVED FOR IMPACT AND NONIMPACT APPLICATIONS. MULLIONS ARE ONLY TO BE USED WITH PGT•APPROVEO FENESTRATION PRODUCTS HIVING CURRENT APPROVALS 10) MULLIONS ARE IN COMPLIANCE FOR USE IN THE HVHZ. 11) QUANTITY OF UNITS WITHIN A MULTIPLE MULLED ASSEMBLY IS UNLIMITED PROVIDED THAT THE SPAN AND OPENING WIDTHIHFIGHT OF EACH INDIVIDUAL MULLION COMPLIES WITH THE REQUIREMENTS OF THIS NOA. ADDITIONAL EXAMPLES OF MULL CONFIGURATIONS: MULL OPENING VAOTH )— HORIZ. MULL LENGTH--( 1 LENGTH I 1 I P OPEN HTHEIGHT l OPENING MILL s' FORIIEIGXTLE 7 MILI / rMULL SINGLE MULLION SINGLE MULLION -_I OPEVERRTI YIIorNFORTICALAXLI OPENNGYAOrH FOR VERTICAL MULL SEE CORRESPONDING DETAILS MULTIPLE MULLIONS FROM FIGURE 1 ABOVE. INSTRUCTIONS: 1) DETERMINE THE DESIGN PRESSURE REQUIREMENT (LBSIFT') FOR THE OPENING USING THE ASCE-7 STANDARD. 2) CHOOSE A MULLION TYPE THAT WILL FIT THE DEPTH OF THE FENESTRATION PRODUCTS FRAME DEPTH. 3) REFER TO SHEET 25 TO DETERMINE IF THE WIND LOADING IS -RECTANGULAR-OR -TRIANGULAR/TRAPEZOIOAL'. GENERAL NOTES__.__ __. _ -. 1 INSTRUCTIONS_._.___. EI EVATION3.... .. .._.___._...- 1 MU L TO 2X V/OOO...... _ _ _ _ 2 MULL TO 1X h MASONRY_. _ __ 2 INSTALLATION NOTES__._ _ _ _ 2 MULL TO MASONRY_.__ _„.._ _ 7 MULL TO STEEL 3TUD__ _..___ 7 MULL TO MULL_ _.__._._- ANCHOR 3PEC3_.__..._.___....3 ALTERNATATE CLIPS._ __._.._._.. RAY MULL INSTALLATION _....._ . 4 1X 2 X 126 MAI SPECS_._.._.._5 1 X 2 X 775 MLRL SPECS_.__._ -.6 I X2 73X 775 MULL SPECS_ _. 7 1 X 2.75 X 65 MULL SPECS._._... 0 1 X 7125 X.500 MULL SPECS__ _ p 1 X 4 X 125 MULL SPECS....._._ 10 IX A X.375 TUBE MULL SPECS. - 11 1 X 4 X.375 T' MULL SPECS _. *11 ..11 125 X 7.100 X 265 MULL SPECS.. 12 1 25 X 3 26 X .100 MULL SPECS. 13 1.25 X 7.25 X 624 MILL SPECS. _ N 1.25 X 7 W X 624 MULL SPECS-_ 15 2 X A X.25 MULL SPECS..._...._ 16 2 X 6 X.25 MULL 3PECS.._.._ 17 120 X211X 125 MULL 3PECa f0 70' X 7 25 BAY MULL SPECS.._ _ .13 AS' X 3 25 BAY MULL SPECS . _ . 20 MULLION 6 CLIP DIMENSIONS..... 21.27 EXAMPLES 16 2..... .... _._.__..24 LGAOING EXAMPLES_._.. _._....25 6) FIND THE CHOSEN MULLIONS MULLION CAPACITY "SIFT-) FROM TABLES 1A THROUGH 16A, ON SHEETS 5 THROUGH 20 RESPECTIVELY, USING THE MULLION TYPE, LENGTH AND OPENING WIDTH OR HEIGHT (DEPENDING IF THE MULLION IS SPANNING VERTICALLY OR HORIZONTALLY). THE MULLION CAPACITY /LOSIM) OBTAINED SHALL MEET OR EXCEED THE DESIGN PRESSURE REQUIREMENT (LBSIFPI FOR THE OPENING OBTAINED IN STEP 1). 5) FROM THE SAME TABLE USED IN STEP I) ABOVE, FIND THE VALUE IN THE NEXT COLUMN ANCHOR CAPACITY REQUIRED (LOS. THIS VALUE REPRESENTS THE WINDLOAD TRANSFERRED TO THE SUBSTRATE BY THE ANCHORS AND MUST BE MET TO ATTAIN THE FULL MULLION CAPACITY, 6) FROM THE ANCHOR CAPACITY (LOS) TABLE ON THE SAME SHEET AND USING YOUR ACTUAL SUBSTRATE CONDITION ( MULTIPLE ANCHORISUBSTRATE/ANCHOR•CLIP PATTERN MAY APPLY) SELECT AN ANCHOR CLIP PATTERN AND VERIFY THAT THE REQUIRED ANCHOR CAPACITY IS MET. 7) IF THE MULLION CAPACITY (LBSFM OBTAINED IN THE TABLE IS HIGHER THAN THE DESIGN PRESSURE REQUIREMENT (LBSFF-) FOR THE OPENING, YOU MAY USE THE "ANCHOR CAPACITY ADJUSTMENT FORMULA” TO OBTAIN THE LOWER ANCHOR CAPACITY REQUIRED WITH THIS VALUE A LOWER ANCHOR CAPACITY OPTION MAY BE SELECTED FOR THE SAME SUBSTRATE 6) VERIFY THE DESIGN PRESSURE RATING (LBSIFT') FOR THE FENESTRATION PRODUCT TO BE USED AND COMPARE WITH THE FINAL MULLION CAPACITY (LBSIFT'1 OBTAINED FOR THE MULLION SYSTEM. THE LOWER OF THE TWO SHALL APPLY FOR THE ENTIRE MULLED FENESTRATION PRODUCT ASSEMBLY. B) HIGHLIGHT OPTION USED AND TABLE VALUES USED IN A SPECIFIC APPLICATION WHEN USING THIS NOA TO APPLY FOR A PERMIT. PRODUCTRBVISBD W "'oplyhlp whh aw Yb116F R r d OS. 11111111/// NG• 5870.5 >i On••' IEgvr15 ((/ ONAL 0410" A. LYNN MIM9. P E. FL P.E b 50705 DETAIL A: MULLION TO 2X WOOD BUCK OR WOOD FRAMING OFFSET CLIP SHOWN) EITHER THE STANDMOOFfSE7MULL r cLw MAv eE NSTALLEOOY TIII$METIKXI . a . . EXTERIOR I DETAIL B: MULLION ATTACHED TO 1X WOOD BUCK AND MASONRY STANDARD CLIP SHOWN) J A Q + 4 EXTERIOR EOGE LLION E SHEETSipiHOIE THEOFFSETuvIS OCATIOKS EDG a21-!23 FW FRAMED WINOOWS, BUT MAY STREWS L 260' —FOR ALL MULLIONS DETAIL B: MULLION ATTACHED TO 1X WOOD BUCK AND MASONRY STANDARD CLIP SHOWN) J A Q + 4 EXTERIOR MULLKIN d r6_L1CK$_T-_j TYP. ANCHOR AND APER SUBSTRATE, R Y ATTAOU.U?Nf SEE SEE TABLES to -lee er OTHERS SEE NOTE 1, N 1 SHEET 1. - YN m I N Jil N 1 1 MAIN 2./KSI T • EDGE COHCREIEORCMU I-- I -f DISTANCE. J1ISEESEETABLES 1 I EDGE DISTANCE 10.168 FOR MASONRY W Q —IANCIK)RS OI O SIDE VIEW Z M ERHER THE Q SrANBARO _j 0 g 4 OFFSET MULL ? Clw MAY BE IHsrALLIED BY Fes•- b 4 IWS IIElN00 J ZEE OO t 4 Q r N Tri. ANCHOR TYP ANCHOR Tri. ANCH0IN PER SUBSTRATE. PER SUBSTMTE, JI PER SUBSTRATE. SEE TABLES IP"M8 SEE TABLES 10.165 SEE TABLES 10.148 _ EOGERiNO _ I DISTANCE BUCKSTRw SEE TABLES .r ' EMBEDMENT / SUCNSTISP IB•IBO T ATTACHMENT BYOTHERS. j_ ATTAGIMEM _ EMBEDMENT' SEE NOTE 1, OYOTHERS. .. •• . • SHEET 1. SEE NOTE 1, ' SHEET •• . ABN 27 KSI CONCRETE OR CMU rROOUCT RBVIlBO SIDE VIEW FRONT VIEW mn P171 y whh 1Ae F1eNlm FRONT VIEW OBTBIBynrPoena N4 'T - 1 . mlwlm n•N .•, INSTALLATION NOTES. 1) ANCHOR EMBEDMENT TO BASE MATERIAL SHALL BE BEYOND WALL DRESSING OR STUCCO Z) QUANTITY OF ANCHORS AND MULLION SIZE SHOWN ABOVE ARE FOR PICTORIAL REPRESENTATION ONLY. BECAUSE THE ANCHOR CAPACITY IS BASED PARTLY ON THE ANCHOR TO ANCHOR OISTANCE, THE CORRECT QUANTITY AND LOCATION OF ANCHORS MUST BE FOLLOWED, REFER TO THE TABLES ON THE FOLLOWING SHEETS. FOR DETAILS A-0, EITHER THE STANDARD OR INTERIOR CLIP MAY BE USED 8) ANCHOR HEAD TYPE MAY BE PANHEAD, HEXHEAO OR FLATHEAD. 4) WOOD BUCKS ARE OPTIONAL, SEE DETAIL C, SHEET 3, 5) FOR MASONRY APPLICATIONS IN MIAMI.OADE COUNTY, USE ONLY MIAMI.OADE COUNTY APPROVED ELCO ULTRACON OR ELCO 114' S S. AGGREGATOR MASONRY ANCHORS. QNY LYNNE NO 58705 •• 7i /= N? LAN 1')&iR P.E. FL P.E.0 58705 EOGE DISTANCEFOR MASONRY THEOFFSETuvIS ANCHORS RECOMMENDED FOR FW FRAMED WINOOWS, BUT MAY ALSO BE USED FOR OTHER FRAME TYPES. MULLKIN d r6_L1CK$_T-_j TYP. ANCHOR AND APER SUBSTRATE, R Y ATTAOU.U?Nf SEE SEE TABLES to -lee er OTHERS SEE NOTE 1, N 1 SHEET 1. - YN m I N Jil N 1 1 MAIN 2./KSI T • EDGE COHCREIEORCMU I-- I -f DISTANCE. J1ISEESEETABLES 1 I EDGE DISTANCE 10.168 FOR MASONRY W Q —IANCIK)RS OI O SIDE VIEW Z M ERHER THE Q SrANBARO _j 0 g 4 OFFSET MULL ? Clw MAY BE IHsrALLIED BY Fes•- b 4 IWS IIElN00 J ZEE OO t 4 Q r N Tri. ANCHOR TYP ANCHOR Tri. ANCH0IN PER SUBSTRATE. PER SUBSTMTE, JI PER SUBSTRATE. SEE TABLES IP"M8 SEE TABLES 10.165 SEE TABLES 10.148 _ EOGERiNO _ I DISTANCE BUCKSTRw SEE TABLES .r ' EMBEDMENT / SUCNSTISP IB•IBO T ATTACHMENT BYOTHERS. j_ ATTAGIMEM _ EMBEDMENT' SEE NOTE 1, OYOTHERS. .. •• . • SHEET 1. SEE NOTE 1, ' SHEET •• . ABN 27 KSI CONCRETE OR CMU rROOUCT RBVIlBO SIDE VIEW FRONT VIEW mn P171 y whh 1Ae F1eNlm FRONT VIEW OBTBIBynrPoena N4 'T - 1 . mlwlm n•N .•, INSTALLATION NOTES. 1) ANCHOR EMBEDMENT TO BASE MATERIAL SHALL BE BEYOND WALL DRESSING OR STUCCO Z) QUANTITY OF ANCHORS AND MULLION SIZE SHOWN ABOVE ARE FOR PICTORIAL REPRESENTATION ONLY. BECAUSE THE ANCHOR CAPACITY IS BASED PARTLY ON THE ANCHOR TO ANCHOR OISTANCE, THE CORRECT QUANTITY AND LOCATION OF ANCHORS MUST BE FOLLOWED, REFER TO THE TABLES ON THE FOLLOWING SHEETS. FOR DETAILS A-0, EITHER THE STANDARD OR INTERIOR CLIP MAY BE USED 8) ANCHOR HEAD TYPE MAY BE PANHEAD, HEXHEAO OR FLATHEAD. 4) WOOD BUCKS ARE OPTIONAL, SEE DETAIL C, SHEET 3, 5) FOR MASONRY APPLICATIONS IN MIAMI.OADE COUNTY, USE ONLY MIAMI.OADE COUNTY APPROVED ELCO ULTRACON OR ELCO 114' S S. AGGREGATOR MASONRY ANCHORS. QNY LYNNE NO 58705 •• 7i /= N? LAN 1')&iR P.E. FL P.E.0 58705 DETAIL E: DETAIL C: -1 126 MN MULLION TO MULLION 'IX g MULLION DIRECTLY ATTACHED TO INTERSECTION NOTES F C C MASONRY STRUCTURE MULLION (U CLIP) 1) MAY BE INSTALLED w -TEE' OR -CROSS' 0 STANDARD CLIP SHOWN) INTERSECTIONS kVAS U 2) MAY BE INSTALLED HORIZONTALLY 1 (SHOWN) OR VERTICALLY. 1 T W CQL3) SEE U-CLIP DRAWINGS, SHEETS 21.23 mEITNER7NEIPERSUBSTRATE. HI(" d, S1AROAR0 I 1 SEE TABLES 16.138 OFFSET MWII I I 1 FOR CORRESPONDING MULLION. y 1 TOP VIEW Z u) CLIP ANY BE I 1 EDGE 015TARCE MULLION Q 1- INSTALLED BY 11 I FOR MA$pNRY J W TNISMETHOO 11 VARIES Y 1 WANCHORS1J 1 I f12STEELSCREW3. = _ SELF•ORILLING OR PRE-0RILL 2 N MULLION ARO USE SMSQ co EXTERIOR ° i• MULLION p —1 EOGEOISTANCE ' 1HE OffSET CII PIS ` 0 1— . MASONRYRECOMMFNOEO FOR / `` Z v F ANCHORS .. WWFIOOWS, BUT MAY LWTERSECTION Sg Y U CLIP F C C J r OTHER BE TYPES. EXTERIOR ¢ Z v 1 TYP.ANCHOR d Z Z Q O1 PER SUSSTMTE, C Z SEE TAKES 15-135 V FO TYP.AHCHOR SEE SHEETS FOR /n PER SUBSTRATE, HOLE LOCATIONS Jf $ 8 SUCKSTRIP SEE TABLES 18.128 N Arra FRONT VIEW EDGE ATTACIUEM DISTANCE_ N W SEE NOTE /. . SEE TABLES (. 1 Z Q O OIBEOAIEM • • ' , •.. ' SHEET 1. - a Z 0EOGE I 15SEE TAKES SIDE VIEW i1 {( 6 MIN 2 7 KSI CONCRETE OR CMU MW 2.7 KSI CONCRETE OR CMU 10.138 a FRONT VIEW SIDE VIEW DETAIL D: MULLION ATTACHED TO STEEL STUD STANDARD CLIP SHOWN) INSTALLATION NOTES. STRUCTURE TYP. ANCHOR 1) ANCHOR EMBEDMENT TO BASE MATERIAL SHALL BE BEYOND WALL DRESSING OR STUCCO. 1 A ` / - PERSUBSTRATE. SEs TABLES 16 135 2) QUANTITY OF ANCHORS AND MULLION SIZE SHOWN ABOVE ARE FOR PICTORIAL REPRESENTATION PRODUCT ILUVISBOtiSEESHEETS ® w1go1)InS 1,Ah ON VI.ddo ONLY. BECAUSE THE ANCHOR CAPACITY IS BASED PARTLY ON THE ANCHOR TO ANCHOR DISTANCE, THE 21-23 FOR I ildl Cb&l ,••,. CORRECT QUANTITY AND LOCATION OF ANCHORS MUST BE FOLLOWED, REFER TO THE TABLES ON THE HOLE Twe,l.,t No (fj FOLLOWING SHEETS FOR DETAILS A-0, EITHER THE STANDARD OR INTERIOR CLIP MAY BE USED. LOCATIONS Dfm RULUON 3) ANCHOR HEAD TYPE MAY BE PANHEAD, HEXHEAOOR FLATHEAD. lilm ode Plodua fun•ry 4) WOOD BUCKS ARE OPTIONAL, SEE DETAIL C, SHEET A I ' 11III 5) FOR MASONRY APPLICATIONS IN MIAMI.OADE COUNTY, USE ONLY MIAMI.OAOE COUNTY APPROVED _ OISTEANCE `` t ONY LYN& ELCO ULTRACON OR ELCO 1/4' S S. AGGREGATOR MASONRY ANCHORS. FOR STEEL 3TUOS THINNER THAN SEC TABLES \ 10EN •'!/! FRONT VIEW 16 GA ANO COMPLIANT MY THE FL BUILDING IB-178 ` ~•••. \. sLc •.,•Fp% COOL A 2X W000 BACKER MUST USEO ATTACHMENT BY 07HERS N0 58705 •> USE WOOD ANCHOR SPECSEXTERIOR SIDE VIEW il• NOTES: • ' - 711 1) FOR 2X WOOD-BACKED STEEL STUDS. WOOD' o,n'.,• S) f'2 S; •. r• 0 Tv ANCHOR VALUES MAY BE USED ; CS •'•F<Ok1DA,,. •'• 2) SEE CORRESPONDING MULLION TABLES, ',• NnL CNG`` SHEETS 5.20, FOR OUANTITY OF SCREWS A"& NNNN t,AIL`I!E FL P.E.A 56705 DETAIL F: FIELD -MODIFIED MULLION CLIP F -CLIP) SEE OETAILS A.E. SHEETS 2 ANO 3 FOR INSTALLATION x TO SPECIFIC SUBSTRATES 0 O 0 SIDE VIEW SHOWN WITH I' X "AW MILLION STANDARD MULLION CLIP MODIFIED TO FR FIELD CONDITIONS iJ \ TV ANCHOR PER SUBSTRATE. SEE TABLES 16.145 INTO WOOD• STEEL. STANDARD CLP TO BE ALUM. CMU OR MASONRY MODIFIED INFIELD EXTERIOR O CODEOSIANCE — F PER ANCHOR NOTES FOR INSTALLATION OPTIONS F 1) DETAIL IS NOT APPLICABLE FOR THE BAY OR 1.26' X 2.11- X.125' MULLION. 2) SEE TABLES 113.198 FOR ANCHOR QUANTITIES AND SHEETS 21.29 FOR HOLE LOCATIONS 9) THE 2X5 CLIP IS NOT SUITABLE FOR THIS APPLICATION. DETAIL G: ANGLE MULLION CLIP ANGLE CLIP) TYP ANCHOR APER SUBSTRATE. SEE TABLES 19.118 I DETAIL H: SAY MULLION INSTALLATION ANGLE CLIP) 70'OR IS' 11111 TTP. ANCHOR 1 PER SUBSTRATE, I SEE TABLES 16B OR IfiB 1I EXTERIOR 1I 2' %6' ANGLE CLP, I 2 PER MULLION END, LUST BE INSTALLEOINSIDE OF BAY MULL. V INTOWOOD. STEEL. ALUM OR MASONRY EXTERICR NSLANCE ^ ® EODE ptOa , •®' / PRODUCT REVISED NucamPlylnBwWllhellalld5 IrtR 4'` @ AcapuP1aT45 5,01 JEDGE O Mate fC OISTANCE I16m1 44P P'O4UT1 CuR110 PERµGQ 11111111//j NOTES FOR INSTALLATION OPTION G 6 H: O` Oti • • • • •., d7/ 1crNgF •. X4;5Q`' 1) USE 2 ANGLE CLIPS PER MULLION ENO. CLIPS MUST BE INSERTED INSIDE OF MULLION. it ; No 56705• tr 2) DETAIL G: SEE TABLES 10.140 FOR ANCHOR QUANTITIES AND SHEETS 21.27 FOR HOLE LOCATIONS n .• 3) DETAIL H: SEE TABLES 1513 OR 160 FOR ANCHOR QUANTITIES AND SHEET 22 FOR HOLE;n q %- Z LOCATIONS mN SS oNnL XA A, LYNN F fkLE%R. P.E. FL P.E.N 58705 REQUIRED INSPECTION SEQUENCE EP# BuILD1NG PERMIT Min Max IIns action Description Footer / Setback Stemwall Foundation / Form Board Survey Slab / Mono Slab Pre our Lintel / Tie Beam / Fill / Down Cell Sheathing — Walls Sheathing — Roof Roof Dry In Frame Insulation Rough In Firewall Screw Pattern Drywall / Sheetrock Lath Inspection Final Solar Final Firewall Final Roof Final Stucco / Siding Insulation Final Final Utility Building Final Door in Final Window Final Screen Room Final Pool Screen Enclosure Final Single Family Residence Final Building (Other) REVISEID: June 2014 Address: ELECTRICAL PERMIT Min Max Inspection Description Electric Underground Footer / Slab Steel Bond to Electric Rough T.U.G. Pre -Power Final gcx7 Electric Final MMECHANICAL PERMIT Min Max Inspection Description Min I1M[ax Mechanical Roug Mechanical Final Gas Unde Gas Roug Gas Final