Loading...
409 Springview Dr 17-176; front doorJAN 17 2017 CITY OF SANFORD BUILDING & FIRE PREVENTION PERMIT APPLICATION Application No: ( % - l 7 Gj Documented Construction Value: $ //40 $ • Sc i Job Address: 4i0 9 SnJ ln<twv"d hiz. Historic District: Yes No Vf Parcel ID: /O-;G.30- 5'D7-00,9,0-00/O Residential P/Commercial Type of Work: New Addition Alteration Repair Demo Change of Use Move Description of Work: 1Q1_L 6PAI drol- an/b awf!, s4mw slze, LGly/ Plan Review Contact Person: w &1G Title: Phone: Vey- 4/ l!i a,?M Fax: Email: C(ezatt1 d 'd GQlyi Property Owner Information Name %%%l malt' -_ & ' -soA Phone: 302/— et,!3 1- 3S- Street: 11m 6dLoli// . al Resident of property? : C City, State Zip: Contractor Information Name )k Y / is z22 Phone: -110- 41111 000 Street: 7,,Z!/ C2t Fax: q07 •- !/,?4- -133"P City, State Zip: aln4rih4r. State License No.: G[3G Architect/ Engineer Information Name: Street: City, St, Zip: Bonding Company: Address: Phone: Fax: E- mail: Mortgage Lender: Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. 1 understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: 511 Edition (2014) Florida Building Code Revised: June 30, 2015 I ennitApplication NOTICE: In addition to the requirements of this permit, there may be additional restietions applicable to this property that may be found in the public records of this county, and there may be additional permits requiredffrom other governmental entities such as water management districts, state agencies, or federal agencies. - If, Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required in order to calculate'a plan review charge and will be considered the estimated construction value of the job at the time of submittal. The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value, credit will be applied to your permit fees when the permit is issued. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Signature of Owner/Agent Date Print Owner/Agent's Name Signature of Notary -State of Florida Date Owner/Agent is Personally Known to Me or Produced ID Type of ID Signature of Contractor/Agent f, Date 7. Prin o tractor/Agent's Name / Signature:.oW. a P ANNETTE SCPTT oNotary Public •State of Florida I My Comm. Expires Jan 16, 2018 Commission # FF 071760 E OF Bonded Pr Mh National Notary Assn. Con Me or Produced ID - Type of ID L BELOW IS FOR OFFICE USE ONLY Permits Required: Building Electrical Mechanical Plumbing Gas Roof Construction Type: Total Sq Ft of Bldg: Occupancy Use: Min. Occupancy Load: New Construction: Electric - # of Amps Fire Sprinkler Permit: Yes No # of Heads APPROVALS: ZONING UTILITIES: ENGINEERING: COMMENTS: FIRE: Flood Zone: of Stories: Plumbing - # of Fixtures Fire Alarm Permit: Yes No WASTE WATER: BUILDING: - 1 Revised: June 30, 2015 Permit Application Jan.12. 2017 8:56AM A + Home Aid Inc No.4487 P. 6/13 PrQ13artV ReCOrd Card Parcel; 10-20-30-507-0000-0010 Owner: A-NDERSO\I MARGARET A Property Address; 409 SPRINGVIGINDR SANFORD, rL32773 Parcel Information Value Summary Parcel 10-20-30-507-0000-0010 j 2017 Working 2018 Certified Values vslu! Owner ANDERSON MARGARETA s— Valuation Method CostlMarket Coal/Markel. Property Address 409 SPRINGMEW DR SANFORD, FL32773 Number or suildings 1 1 Mailing 409$PRlNGVIEWDR SANFORD, FL32773 Depreciated Bid* g Valve i $119,955 86,629 SoKvislonNsme OROVEVIE.WVILLACE 31RD ADD E.EL LT Depreciated EXFT Value Tax District Sl-SANFORD Lend Value (market) 25,000 25.000 DOR Use Code 01-SINGLE FAMILY Land Value A@ Exemptions 00-HOMESTEAD(2003) Portability Adj Save Our Homes Adj $55,386 33.605 Amendment 1 Ad) P&G Adj $0 SO Assessed Value $76,570 78,024 Tax Amount without SOH: $1,424.32 2016 Tax Bill Amoom $750,68 lira—EAIMM Save Our Homes Savings: $673.64 Does NOT INCLUDE Non Ad Valorem Asuossmer)(5 Legal Description LOT I GROVEVIEWVLLAGE 3RD ADD REPLAT PS 26 PGS 9 & 10 Taxes Taxing Authority I'Aslestmenil Value 1-Exempt values Taxable Value CIly Sanford 78,570 60.000 SJVVM(.531ni Johns Water Management) 70,670 i 50,000 28.570 County Bonds 78.570 50,000 County General Fund 78,570 50,000 28,570 schools 78,570 25.000 93,570 sales Description a Page nl Qualified Vacimp IIb.---,---.--......bb.."."bb.., WARRANTY DEED j 9/112002 0a506 1 0003 109,800 1 Yes Improved I I QUIT CLAIM DEED 8/1J2002 i too No Improved WARRANTY DEED 1011/2000 1795 S83,600 Yes Improved PECIAL WARRANTY DEED j 12/ /19 0272 i 64.800 i No improved I CORRECTIVE DEED 2/1/1996 100 No Improved I SPECIAL WARRANTY DEED 12/1/1996 103ma 1408 100 No proved CERTIFICATE OF TITLE 111111905 1 QZ M" M 68,900 No mproved CERTIFICATE OF TITLE 811/1994 0563 1 DO j No Improved WARRANTY DEED 011/1092 77,100 I Yes Improved WARRANTY DEED 611/1990 102158 j 1106 i$77,500 I Yes Improved Page 1 of 2 (11 items) Ill 2 Land Jan,12. 2017 8:56AM A + Home Aid Inc No,4487 P. 7/13 11...."--, - * - - - * , * 11 1 1 .... __ _" * * , , , . .. iMethodFrontageDepthnitsLandValue LOT o.00 0.001 1 425,000.00 1 $26.00011 Building Information correct QI?cKHe I - -""" T"' --'---- --------- --- - Year BuiltADescriplionActual/EfteclIve Fixtures Bad 881h Bass Area TolaISF LiVing SF ExI Wall Ad) Value Rapt Value Appendages 1 SINGLE 1086 0 1_15 m1,2551 1,911 1.2CON $69,956 $104,600 FAMILY BLOCK 3LOCKDescription Area I PermIte 1: ADDITION - RESIDENTIAL hOn75? ADDITION - RESIDENTIAL Extra Features Da3chption OPEN PORCH 180.130 FINISHED I GARAGE 441. 00 FINISHEDOPEN PORCH 35.00 FINISHED 7±=== j Agency Amount CO Dele Parmil Dale SANFORD 0.750 4I50006 SANFORD 0 1/112006 n. la8 No Extra Features 2017-01-12 14:36 0264EX 4073331117 ZWsrA-c.1- Ro. l mil/ VS)5,74 Homeni U. Important additional information regarding Customer's r Scope: This "Agreement- consists of this page, the foil Supplement if applicable, and any drawings or Change Ord between the Customer identified. on the Invoice and Tht Agreement shall be performed by a licensed and insured thi perform architectural or engineering services, nor does it mai Depot and its Authorized Service Provider will perform Install Pa men Sch dui : Payment is required Immediately as follows: Payment: $ 11 2 55SalesTax: $-- Q flDTotalAmountofSale: $ 4073331117 >> 407 696 7356 P 1/1 Page 5 of 10 NO. H0264-27886 Went Agreement tEAD THIS 6 i 1 35ib hts may be contalnet in an attached State Supplement. ving General Terms nd Conditions, the Invoice, the State s expressly made a p rt of this Agreement. The Agreement is Home Depot. Any in itallabon services provided under this party Authorized Se ce Provider. The Home Depot does not structural changes to ellings or other structures. The Home on services in accord nce with applicable law. Due in full Imm, If applicable. Includes all app taxes. Excludes Any interest payments or other finance charges will be determined y Customer's separateHomeDepotisNOTaparty, and will be in addition to Customer's p yment under this Agreeconditionsofthecardholderorloanagreement, as applicable. No f nds should be made pahowever, Authorized Service Provider may collect Customer's pa nt(s) made payable to discounts, rebates, and ii charges." iholder or loan agreement, to which The t. Customer is subject to the terms and e to Authorized Service Provider; Home Depot, nti at Del a ins tlo the e Deliver Date: TBpStart Date; j 1 finish Date: AcceptanCe an A orf tion; Customer authorizes TheandservicesincludedontheInvoice. Customer further Home Depot to order atid arrange for the delivery of all goods agreement between Customer and The Home Depot with discussions and agreements, either oral or written relatinG grees and understan egard to said goods s that this Agreement is the entire nd services and supersedes all prior assigned or amended except by a writing signed by CustomthatCustomerhasread, understands, to said goods and se and The Home Depon ices. This Agreement can not be Customer acknowledges and agreesvoluntarilyacceptstheofthisAgreementatthetimeCustomersignstheAgreement- terms of and is entitlec Installation Profess to and has received a complete copy information may need to be provided later and as such thssigned. information may be amittednal's license number and permitting at the time this Agreement is Electronic 8' alinteThe parties to the Agreement agAgreementarendedtoauthenticate a that the digital sign tures of the parties included in thisthiswritingandtohCustomeracknowledgesthatheorsheisthepersonnamedsaledevice. e the same force and e c n The Home Depot cor feet as the use of manual signatures. tract number identified theon point of CANCELLATION: CUSTOMER MAY CANCEI OBLIGATION BY DELIVERING WRITTEN NOTI THIS AGREEME 4T WITHOUT PENALTY OR THIRD BUSINESS DAY AFTER SIGNING TH TO THE HOME AGREEMENT. EPOT BY MIDNIGHT ON THE ATTACHED HERETO CONTAINS A FORM TO THE STATE SUPPLEMENT LAW IN CUSTOMER'S STATE. E IF ONE IS SPECIFICALLY PRESCRIBED BY under such circumsbusinessdaysafterTheHomeDepot's nces, Customer's pa ent(s) will be returned within ten (10) receipt of Customer's once. Gu tourers Signature r 01/07/2017 Date Authorized Service Provider's Full Susinesa/Trade Name. Address and xLicenseNo. or No(s)., as applicable: Associate's/Authorized $e Provider's Full Signature Yale Associate: Please print you salesperson's license number, if applicable. License Authorized Service Providers Tel No. Home Depot U.S.A. Inc.. 2455 Paces Ferry d. N.W.. Bldg B.3, Atlanta, Gaon Is 30339 3/2011 Page 5 of 10 No, H0264-27886 Customs nnv p0--icizm p 4—mMMZ Z Om acK m=ozSM MDCnO_,QvO0ZOG)m Om0-mOm= a 0 m0 C z ci' m00>z D ncn zrn00m mi L. r" O Z- nmZ mmO m co M 00= m=o o T3 jFnMK- 4mDm 2 MMZ0 n 0- 0 -v=-Mzo c OZTT6MDD Z rr 4 ion d er6On Rewde-^c t, q, q9 spHagoe,ur n Opening will meet 35 PSF +/- .requ.lrement dN eG tl ` I n a a< Ilrl da C.pvttrS 11'o` BCIS Home log In User Registration Hot Topics Submit Surcharge i Stats & Facts i Publications FBC Staff BCIS site Map links 1 Search Busines J} PY Y1"' Product Approval rofess) `naI IUSER: Public User Regulation iAY1.7141111IRlRRA Prr.uct AQgr.9..val M..;ng > Produ4t_or_P.gDlip jign S..d rSh > APRhGatgn 4S.i > Application Detail Vt' i i'Y 4Yh FL # FL15129-R3 Application Type Revision Code Version 2014 Application Status Approved Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Florida Engineer or Architect Name who developed Lyndon F. Schmidt, P.E. the Evaluation Report Florida License PE-43409 Quality Assurance Entity National Accreditation and Management Institute Quality Assurance Contract Expiration Date 12/31/2015 Validated By Ryan 3. King, P.E. F Validation Checklist - Hardcopy Received Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By 9 Trinity Glass International 33615 1st Way S Federal Way, WA 98003 253)875-7300 rickw@rwbldgconsultants.com Vivian Wright rickw@rwbldgconsultants.com Exterior Doors Swinging Exterior Door Assemblies Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer r Evaluation Report - Hardcopy Received 7 76 a FL1S129 R3 COI CERTIFICATE OF INDEPENDENCE.Ddf Standard Year 101/I.S.2/NAFS 2002 ASTM E1886 2002 ASTM E1886 2005 ASTM E1996 2006 ASTM E1996 2002 ASTM E330 2002 ASTM E331 2000 TAS 202 1994 1 of 5 6/29/2015 4:15 PM Sections from the Code Product Approval Method Method 1 Option D Date Submitted 05/01/2015 Date Validated 05/01/2015 Date Pending FBC Approval 05/09/2015 Date Approved 06/23/2015 Date Revised 06/25/2015 C. of Dm.#- FL # Model, Number or Name Description i 15129.1 a. Fiberglass Door 6'8 Single Opaque "Impact" Fiberglass Door - Outswing/Inswing Configuration (X) Limits of Use Installation Instructions Approved for use in HVHZ: No FL15129 R3 II Inst 15129.1.pdf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 15129.1 for Design Pressure Ratings by FL15129 R3 AE Eval 15129 1.odf I specific Model and for any other additional use limitations Created by Independent Third Party: Yes and installation instructions. I 15129.2 I b. Fiberglass Door 6'8 Single Opaque "Impact" Fiberglass Door with Non -Impact" Sidelite or Sidelites - Outswing / Inswing Continuous Head and Sill Configurations (OX or XO; OXO) Limits of Use Installation Instructions Approved for use in HVHZ: No FL15129 R3 II Inst 15129.2.pdf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 15129.2 for Design Pressure Ratings by FL15129 R3 AE Eval 15129.2.odf specific Model and for any other additional use limitations Created by Independent Third Party: Yes and installation instructions. 15129.3 1 c. Fiberglass Door 6'8 Single Opaque "Impact" Fiberglass Door with Non -Impact" Sidelite or Sidelites - Outswing / Inswing Configurations (OX or XO; OXO) I Limits of Use Installation Instructions Approved for use in HVHZ: No FL15129 R3 II Inst 15129.3.odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 15129.3 for Design Pressure Ratings by FLl._5129 R3 AE Eva1 15129.3_pdf specific Model and for any other additional use limitations Created by Independent Third Party: Yes I and installation instructions. I 15129.4 j d. Fiberglass Door 6'8 Double Opaque "Impact" Fiberglass Door with or without "Non -Impact" Sidelites - Outswing / Inswing Configurations (XX; OXXO) Limits of Use Installation Instructions Approved for use in HVHZ: No FL15129 R3 1I Inst 15129.4 odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 15129.4 for Design Pressure Ratings by FL15129 R3 AE Eval 15129.4.pdf specific Model and for any other additional use limitations Created by Independent Third Party: Yes and installation instructions. I-- ....... -.... _....... ................................. ---- - ...- - - _ - 15129.5 e. Fiberglass Door 6'8 Single Glazed "Non -Impact" Fiberglass Door - 1__.._.....---------- ----------- ------ ---- - ..... Outswing/Inswing Configuration (X) a Limits of Use Installation Instructions j Approved for use in HVHZ: No FL15129 R3 II Inst 15129.5.odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports 2 of 5 6/29/2015 4:15 PM Other: See INST 15129.5 for Design Pressure Ratings by I FL15129 R3 AE Eval 15129.5.odf specific Model and for any other additional use limitations I Created by Independent Third Party: Yes and installation instructions. 1 15129.6 f. Fiberglass Door 68 Single Glazed "Non -Impact" Fiberglass Door with Non -Impact" Sidelite or Sidelites - Outswing / Inswing Continuous Head and Silt Configurations (OX or XO; OXO) Limits of Use Installation Instructions Approved for use in HVHZ: No FL15129 R3 II Inst 15129.6.odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 15129.6 for Design Pressure Ratings by FL15129 R3 AE Eval 15129.6.pdf specific Model and for any other additional use limitations Created by Independent Third Party: Yes and installation instructions. 15129.7 I g. Fiberglass Door 6'8 Single Glazed "Non -Impact" Fiberglass Door with Non -Impact" Sidelite or Sidelites - Outswing / Inswing Configurations (OX or XO; OXO) Limits of Use Installation Instructions Approved for use in HVHZ: No Approved for use outside HVHZ: Yes FL15129 R3 II Inst 15129.8.odf Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 1S129.7 for Design Pressure Ratings by FLIS129 R3 AE Eval 15129.7.ndf specific Model and for any other additional use limitations Created by Independent Third Party: Yes and installation instructions. t.......... -.... __.._............. __...................... _................ .__.- ................. 15129.8 h. Fiberglass Door I ....... - ---- ------- ---- 6'8 Double Glazed "Non -Impact" Fiberglass Door with or without "Non -Impact" Sidelites - Outswing / Inswing Configurations (XX; OXXO) Limits of Use Installation Instructions Approved for use in HVHZ: No FL15129 R3 II Inst 15129.8.odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 15129.8 for Design Pressure Ratings by FL15129 R3 AE Eval 15129.8.odf specific Model and for any other additional use limitations Created by Independent Third Party: Yes and installation instructions. 15129.9 i. Fiberglass Door 6'8 Single Opaque "Non -Impact" Fiberglass Door - Outswing/Inswing Configuration (X) Limits of Use Installation Instructions Approved for use in HVHZ: No FL15129 R3 II Inst 15129.9.odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 15129.9 for Design Pressure Ratings by FL15129 R3 AE Eval 15129.9.pslf specific Model and for any other additional use limitations Created by Independent Third Party: Yes and installation instructions. 15129.10 j. Fiberglass Door 6'8 Single Opaque "Non -Impact" Fiberglass Door with Non -Impact" Sidelite or Sidelites - Outswing / Inswing Continuous Head and Sill Configurations (OX or XO; OXO) Limits of Use Installation Instructions Approved for use in HVHZ: No FL15129 R3 II Inst 15129.10.odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 15129.10 for Design Pressure Ratings by FL15129 R3 AE Eval 15129.10.1)df specific Model and for any other additional use limitations Created by Independent Third Party: Yes and installation instructions. r - - - - - - --._.._........_..._......._ _..._............. 15129.11 j k. Fiberglass Door 6'8 Single Opaque "Non -Impact" Fiberglass Door with Non -Impact" Sidelite or Sidelites - Outswing / Inswing j Configurations (OX or XO; OXO) Limits of Use Installation Instructions Approved for use in HVHZ: No FL15129 R3 II Inst 15129.11.odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 15129.11 for Design Pressure Ratings by FL15129 R3 AE Eval 1 12 .11.pddf specific Model and for any other additional use limitations Created by Independent Third Party Yes and installation instructions. 1....................... --... ---...................... _..__................. ---...------------------------------- --- ----- -- -- ...- 3 of 5 6/29/2015 4:15 PM 15129.12 j I. Fiberglass Door - - 6'8 Double Opaque "Non -Impact" Fiberglass Door with or without "Non -Impact" Sidelites - Outswing / Inswing i—_------ Configurations (XX; OXXO) Limits of Use Installation Instructions Approved for use in HVHZ: No FL15129 R3 fI Inst 15129 12 odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Other: See INST 15129.12 for Design Pressure Ratings by Evaluation Reports FL15129 R3 AE Eval 15129.12 odf specific Model and for any other additional use limitations Created by Independent Third Party: Yes and installation instructions. 15129.13 m. Fiberglass Door 8'0 Single Opaque "Impact" Fiberglass Door - L_.......... _.............. _....... _.._....................... _...._........._...._._......._ Outswing/Inswing Configuration (X) Limits of Use Installation Instructions Approved for use in HVHZ: No FL15129 R3 II Eval 15129 14 odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 15129.13 for Design Pressure Ratings by FL15129 R3 AE Eval 15129 13 odf specific Model and for any other additional use limitations Created by Independent Third Party: Yes and installation instructions. 15129.14 j n. Fiberglass Door 8'0 Single Opaque "Impact" Fiberglass Door with i Non -Impact" Sidelite or Sidelites - Outswing / Inswing Continuous Head and Sill Configurations (OX or XO; OXO) Limits of Use Installation Instructions Approved for use in HVHZ: No FL15129 R3 II Inst 15129.14.odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 15129.14 for Design Pressure Ratings by FL15129 R3 AE Eva] 15129.14.pdf specific Mode] and for any other additional use limitations Created by Independent Third Party: Yes and installation instructions. f..... -......... _........_._.....---... -....... _.-._...._.........-._........................... 15129.15 ; o. Fiberglass Door 8'0 Single Opaque "Impact" Fiberglass Door with Non -Impact" Sidelite or Sidelites - Outswing / Inswing I Configurations (OX or XO; OXO) Limits of Use Installation Instructions Approved for use in HVHZ: No FL15129 R3 II Inst 15129.15.odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 15129.15 for Design Pressure Ratings by FL15129 R3 AE Eval 15129 15 pd specific Mode] and for any other additional use limitations Created by Independent Third Party: Yes and installation instructions. 15129.16 p. Fiberglass Door 8'0 Double Opaque "Impact" Fiberglass Door with or without "Non -Impact" Sidelites - Outswing / Inswing I Configurations (XX; OXXO) Limits of Use Installation Instructions Approved for use in HVHZ: No FL15129 R3 II Inst 15129.16.odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 15129.16 for Design Pressure Ratings by FL15129 R3 AE Eval 15129 16.odf specific Model and for any other additional use limitations Created by Independent Third Party: Yes and installation instructions. 15129.17 I q. Fiberglass Door 8'0 Single Glazed "Non -Impact" Fiberglass Door - I _.......... ............................. .....---- Outswing/Inswing Configuration (X) Limits of Use Installation Instructions Approved for use in HVHZ: No FL15129 R3 II Inst 15129.17.pdf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 15129.17 for Design Pressure Ratings by FL:151.29R3 AE Eyal 15129.17_p0_f specific Model and for any other additional use limitations Created by Independent Third Party: Yes and installation instructions. i--................ ----...._.._...---........-......-------- ------ 15129.18 ! r. Fiberglass Door 8'0 Single Glazed "Non -Impact" Fiberglass Door with i Non -Impact" Sidelite or Sidelites - Outswing / Inswing 1 - Continuous Head and Sill Configurations (OX or XO; OXO) 4 of 5 6/29/2015 4:15 PM Limits of Use Installation Instructions Approved for use in HVHZ: No FL15129 R3 II Inst 15129.18.[df Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 15129.18 for Design Pressure Ratings by FL15129 R3 AE Eval 15129.18.pdf specific Model and for any other additional use limitations Created by Independent Third Party: Yes and installation instructions. 15129.19 s. Fiberglass Door 8'0 Single Glazed "Non -Impact" Fiberglass Door with Non -Impact" Sidelite or Sidelites - Outswing / Inswing Configurations (OX or XO; OXO) Limits of Use Installation Instructions Approved for use in HVHZ: No FL15129 R3 II Inst 15129.19.odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 15129.19 for Design Pressure Ratings by FL15129 R3 AE Eval 15129 19 odf specific Model and for any other additional use limitations Created by Independent Third Party: Yes and installation instructions. 15129.20 t. Fiberglass Door 8'0 Double Glazed "Non -Impact" Fiberglass Door with or without "Non -Impact" Sidelites - Outswing / Inswing Configurations (XX; OXXO) 1......_._...................................... .......... .......... ... __.... __._............. _............ _.......... Limits of Use Installation Instructions Approved for use in HVHZ: No FL15129 R3 II Inst 15129.20.0f Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 15129.20 for Design Pressure Ratings by FL15129 R3 AE Eval 15129.20.1)df specific Model and for any other additional use limitations Created by Independent Third Party: Yes and installation instructions Next Contact Us :: 1940 North Monroe Street Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida :: Privacy Statement :: Accessibility Statement :: Refund Stat moot Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. "Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address R they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click bgM. Product Approval Acoepts: al ® aChie M Credit 90 5 of 5 6/29/2015 4:15 PM R W R W Building Consultants, Inc. l Consulting and Engineering Services for the Building IndustryI7 P.O. nog 230 Valricu. FL 33595 Phone 813.659.9197 Floridn Board of Professional Engitvers Certiftcnie of Authmiz lion No. 9813 Product Category Sub Category Manufacturer Product Name Trinity Glass International Glazed Fiberglass Exterior Swinging Exterior Door 4621 192nd St. East Door Doors Assemblies Tacoma, Washington 98446 Non -Impact" Phone 235-875-7300 Facsimile 235-875-7301 Inswing/Outswing Scope: This is a Product Evaluation report issued by R W Building Consultants, Inc. and Lyndon F. Schmidt, P.E. (System ID # 1998) for Trinity Glass International based on Rule Chapter No. 61G20-3, Method 1D of the State of Florida Product Approval, Department of Business & Professional Regulation. RW Building Consultants and Lyndon F. Schmidt, P.E. do not have nor will acquire financial interest in the company manufacturing or distributing the product or in any other entity involved in the approval process of the product named herein. Limitations: 1. This product has been evaluated and is in compliance with the 5th Edition (2014) Florida Building Code (FBC) structural requirements excluding the "High Velocity Hurricane Zone" (HVHZ). 2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment to base material shall be beyond wall dressing or stucco. 3. When used in areas requiring wind bome debris protection this product is required to be protected with an impact resistant covering that complies with Section 1609.1.2 of the FBC. 4. For 2x stud framing construction, anchoring of these units shall be the same as that shown for 2x buck masonry construction. 5. Site conditions that deviate from the details of drawing FL-15129.5 require further engineering analysis by a licensed engineer or registered architect. 6. See drawing FL-15129.5 for size and design pressure limitations. Supporting Documents: 1. Test Report No. TEL 06-0223-3 TEL 06-0223-2 TEL 01470437 TEL 01471169 TEL 01471168 2. Drawing No. No. FL-15129.5 3. Calculations Anchoring Test Standard TAS 202-94 101A.S2/NAFS-02 ASTM E330-02 ASTM E330-02 & E331-00 ASTM E330-02 & E331-00 Testinq Laboratory Testing Evaluation Lab.,lnc. Testing Evaluation Lab.,lnc. Testing Evaluation Lab.,lnc. Testing Evaluation Lab.,lnc. Testing Evaluation Lab.,lnc. Prepared by RW Building Consultants, Inc. (CA #9813) Prepared by RW Building Consultants, Inc. (CA #9813) 4. Quality Assurance Certificate of Participation issued by National Accreditation and Management Institute, certifying that Trinity Glass International is manufacturing products within a quality assurance program that complies with ISO/IEC 17020 and Guide 53. Sheet 1 of 1 Signed by Wendell W. Haney, P.E. Wendell W. Haney, P.E. Lyndon F. Schmidt, P.E. V.K. Wright V.K. Wright Signed & Sealed by Lyndon F. Schmidt, P.E. Signed & Sealed by Lyndon F. Schmidt, P.E. No 4,3409 cc STATE OF ' f $ 631tdt' LyndonFL PE No. 43409 5/1/2015 TRINITY GLASS 4 INTERNATIONAL GLAZED FIBERGLASS DOOR INSWING / OUTSWING NON -IMPACT' GENERAL NOTES 1. This product has been evaluated and is in compliance with the 5th Edition (2014) Florida Building Code (FBC) structural requirements excluding the "High Velocity Hunicane Zone" HVHZ). 2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment to base material shall be beyond wall dressing or stucco. 3. When used in areas requiring wind bome debris protection this product is required to be protected with an impact resistant covering that complies with Section 1609.1.2 of the FBC. 4. For 2x stud framing construction, anchoring of these units shall be the same as that shown for 2x buck masonry construction. 5. Site conditions that deviate from the details of this drawing require further engineering analysis by a licensed engineer or registered architect. TABLE OF CONTENTS SHEEN DESCRIMON 1 Typical elevations, design pressures & general notes 2 Door panel details - Rush glozing 3 Door panel cletalts - lip a lonn 4 Horizontal cross sections 5 Verlical cross sections 6 Buck and frame anchoring 7 Components 8 1 Bill of materials 37.5t7' MAX. O.A. I FRAME WIDTH JAMS TYPE fY........ : _. WOOD . + 70.0 70.0 + 47.0 - 47.0 37.50" x 81.88" PVC FIBERGLASS/COMP + 60.0 60.0 + 47.0 - 47.0 TM U: N.T.S. c. BY. JK o c Br: LFS 3 1rn NONO.: a FL-15129.5 n c rr 1 of 8 a PVC STILE CAP DOOR SKIN I 1.58' { I I r JLVL STILE 0.10" FOAM CORE 0.31" 35.75' MAX. PANEL WIDTH EXTERIOR LOCK BLOCK INTERIOR HORIZONTAL CROSS SECTION 2 21.0" HOT MELT SEALANT . 5' GLASS BITE MAX. D.L.O. SILICONE 1"O.A. THK GLASS a 1/8"TEMPERED GLASS AIR SPACE I 1/8"TEMPERED 2 GLASS 8 X 1-1/WSELF ALUMINUM BUTYL L= THREADING SCREW OR STAINLESS STEEL O SPACER SYSTEM rj N GI GIAZINGDETAIL Z Fush Ute Frame PVC STILE CAP PVC COMPOSITE 1.58" r TOP RAIL LVLZuLt 0.10" 1.24" TFr FLUSH GLAZED FRAME ABSorPC/ASA iN C/ MAHOGANY 111E FRAME ABS or TASA d X B2 .5" GLASS BYTE SEE b HOT MELT SEALANT I"OA. THK GLASS In HARDWARE SEE foo SILICONE CHART DETAIL I Tr h 40 FIBERGLASS DOORwithFLUSHGLAZING FIBERGLASS DOOR SKIN: MIN. 0.070" THK. FOAM CORE MATERIAL: POLYURETHANE NOTE: I. Spacing for lite frame screw is as follows: Top and Bottom: 2-3/4" from comers 3 equally spaced thereafter (4 total) Sides: 2-3/,('from comers S equally spaced thereafter 18 total) DETAIL 1 1/8"TEMPERED GLASS AIR SPACE 1 /8" TEMPERED GLASS 8X1-1/8 SELF PALUMINUMBUTYL THREADING SCREW OR STAINLESS STEEL SPACER SYSTEM G3 GLAZING DETAILGLAZINGFrame MODEL .:...:'::. ...:..:: . KNOB: SIGNATURE SERIESKWIKSET DEADBOLT: SIGNATURE SERIES (980) KNOB i DEADBOLT: KWIKSET SIGNATURE SERIES COMBO PACK (991) KNOB: F SERIESSCHLAGE DEADBOLT: 960 SERIES DOOR SKIN PVC COMPOSITE BOTTOM RAIL ssss rr cli o 4u U N •• J O U C2SC[ M1 m Ct9 Wo m. g 3d a`a li OcZ0 p cw 3 d 2 VERTICAL CROSS SECTION 2 c r DATE 1118112 scuE N.T.S. M. BY_ JK i ax BY: LFS 3 BBAwBi ao.: o FL-15129.5 a xm 2 OF 8 " n I PVC STILE CAP 0.10' 0.31" - 35.75' MAX. PANEL WIDTH 21.0' MAX. D.L.O. 4 d v 2 0 w a X COObSEE HARDWARE CHART id FIBERGLASS DOOR PANEL with LIP LITE GLAZING FIBERGLASS DOOR SKIN: MIN. 0.070' THK. FOAM CORE MATERIAL: POLYURETHANE DETAIL 1 I n h INTERIOR 1 HORIZONTAL CROSS SECTION 3 HOT MELT SEALANT 1 /7' GLASS BYTE A3 1"O.A. THK GLASS 1/8"TEMPERED GLASS AIR SPACE It J_ 1/8'TEMPERED GLASS k8 X 1-1/7' PPH SMS ALUMINUM BUTYL SEE NOTE 1) OR STAINLESS STEEL SPACER SYSTEM G2 GLAZING DETAIL Up Lite Frome F i A3AM or C/ASAE DETAIL i NOTE: 1. Spacing for life trome screw is as follows: Top and Bottom: 2" from each comer and of centerline (3 total) Sides: 7trom each comer and equally spaced thereafter (8 total) PVC TOP RAIL T DOOR SKIN EXTERIOR INTERIOR 0 0 7 PVCCOMPOSITEBOTTOM RAIL VERTICAL CROSS SECTION 3 RS1l l'I''' z _• ••• A: n dr. Z o Z E U; z u g 3 9mC,W H doaar m o a E 4 0 Dz c 4i 3`0: 0 O J c j o V 0O O o rx n a o+ 1118112 ` sCALL. N. T.S. ` M. By: JK u CW. BY: LFS 3 oanwwa W u FL-15129. 5 c sect 3 or 8 a 5 i 1 4 2..........' EMB. (TYP.( Q: z4 1 2 3 4 F C404 Ir*11• a n m Z 4 v\[ 12 o Z U m INTERIOR V 8 `u 1 ° o a W maa a O 0Eo` _ 4 3d 4 2 F U EXTERIOR V) 23 H A o z 4 1 HORIZONTAL CROSS SECTION I-I/4"MIN. 4 Shown w/1Xsub-buck 1-1/4'MIN. N EMB. (TYP.( EMB. (TYP.( ofL555 L a a 0.15" j' C CSINK C SI K —{ C m TYP.) TYp ) U 1 2 3 4 1 2 3 4 INTERIOR INTERIOR N Y-.1 mo o 12 40 40 12 z N a W C, v v aoo z f N O m a° n N.-0 24 26 EXTERIOR EXTERIOR 23 are 1 118112 suu N.T.S. ° D B 18 g D DM. er: JK m' E LFS 3E 11 HORIZONTAL CROSS SECTION L2 HORIZONTAL CROSS SECTION Dm FL a 4 Oulswing shown - Inswing also approved 1 4 Ouhw ng shown - Insw ng oleo approved FL— 15129.5 aa swm 4 or 8 p INTERIOR EXTERIOR INTERIOR ri' VERTICAL CROSS SECTION INTERIOR 5 J Shown w/l x sub -buck fit% m u n y• • N n z O m O m y V N 2m v a • Z .< Eo zm°oo Vt0dNi pod ma`am 3 4 o E 0_ u WaSd z z 0 U ut y 0 o m U p O Z a' i 3 VERTICAL CROSS SECTION m 5 Ouhwing sill - high dam 5 VERTICAL CROSS SECTION Inswing sill WE 1 18 12 scut N.T.S. DWG. BY: JK CHK. Err: LFS onAwWG No.: FL-15129.5 sHEET 5 of 8 2X BUC MASONF OPENIM BUCK ANCHORING CONCRETE ANCHOR NOTES: I. Concrete anchor locations at the comers may be adjusted to maintain the min. edge distance to mortarjoints. 2. Concrete anchor locations noted as "MAX. ON CENTER" must be adjusted to maintain the min. edge distance to mortar joints, additional concrete anchors may be required to ensure the "MAX. ON CENTER" dimension are not exceeded. 3. Concrete anchor table: ANCHOR ': ANCHOR: MIN MIN :CLEARANCE_ MIN.CLEARANCE SIZE::EMBEDMENf 10MASONRY TOADJACEM:; iEDGE..:':. ANCHOR..:..:-'. ITW BUILDEX 3/1V 1.1/4" 3" 1.1 ? TAPCON° 14" 1.1 4" 2" 4" ELCO 114" 1.1/4" 1" 4" ULTRACONs WOOD SCREW INSTALLATION NOTES: 1. Maintain a minimum SAr edge distance. I"end distance, d I"o.c. spacing of wood screws to prevent the splitting of wood. SEE HINGE DETAIL 2 SEE HINGE DETAIL I HINGE JAMB L 2X BUCK to F IX BUCK TYP. HEAD AND JAMBS 2X BUCK DOOR FRAME QUO MASONRY OPENING — TYP. SILL P FRAME ANCHORING Masonry construction HINGE DETAIL I BUCK BUCK IN n oo: gv axZ{ Eo ZmOcw8 c 4 o ui Zo° w 8 `d 64 2X BUCK Lu H IXBUCK u Y 0 o: 23 o STRIKE JAMB HINGE DETAIL 2 2X BUCK IX BUCK E: N.T.S. X er: LFS avurc No.: FL-15129.5 rr _L OF 8 ry 1 4.56' ----i i-- 2.39' --i I HEADANDJAMBS Wood 4.56" L Age In 2.44 CHEAD AND JAMBS 3 PVC 4.58 ---{ m 4.56" o I-- 2.44" s-- I 2 HEAD AND JAMBS Composite PVC Base w/ Fiberglass Wrap 4.56" —{ to - `•` _ 4 HEAD AND JAMBS PVC 5.62' 1 1 S INSWING THRFSHOLD N 2S 01RSWING THRESHOIOffigh-dam 4.ST b WING TFIRESHOID sZ ol: ian h LrIE *l N o n m z UN •• y L 2EE O O Z e m u cEoZ c i iJi J co Q. o No0 U 0 0 = < U 0: O O wa a 0 SKLKCEY. RIGNr Y SILLKEY. LEFT SCALE: NONE 0 SCALE-- NONE a 1.22' Fto d O O O f 5° 19 SIL'k DETAILS 0planal c o+Tc 1 18 12 saLE: N.T.S. owc. Err: JK c aoc er: LFS 3 FL-15129.5 ET 7 OF 8 BILL C U2 ie. o; » F n L11*jl M 11 Z o coozVNoaUotECn9.z xi o a V. toM IL o l\\ i ? 0v` d vl a ti w U m 4o Z J m 0 00 a a mS U Lo o leN Z W m o N a W Q 0 W j n N zz C Z DATE 1118112 i Saar: N.T.S. ° Cwc. ft. JK m CHIC. BY-.LFS 3 wawwC NO: FL-15129.5 0 sHm 8 OF 8 " OF MATERIALS REM • OESCRIP110N MATERIALA1XBUCKSG >= O.SS WOOD B 2X BUCK SG >= 0.55 WOOD C 1 /4" MAX. SHIM SPACE D 1 /4" X 2-3/4" PFH ELCO OR ITW CONCRETE SCREW STEEL E MASONRY - 3,000 PSI MIN. CONCRETE CONFORMING TO ACI 301 OR HOLLOW BLOCK CONFORMING TO ASTM C90 CONCRETE F 1 /4" X 3-3/4" PFH ITW CONCRETE SCREW STEEL H 3/16" X 3-1 /4"PFH ITW CONCRETE SCREW STEEL J 9 X 2-1 /4"PFH WS STEEL l 8 X 2-1/7'PFH WS STEEL P 1/4" X 2-3/4" PFH ELCO OR ITW CONCRETE SCREW STEEL 1 HEAD &JAMB (FINGER -JOINT PINE - SG >= 0.42) WOOD 2 HEAD &JAMB FIBERGLASS/COMP 3 HEAD &JAMB PVC 4 HEAD 8 JAMB PVC 5 INSWING THRESHOLD ALUMINUM W/ COMPOSITE SUBSTRATE ALUMINUM 6 DOOR BOTTOM SWEEP PVC 8 6 X 1-1 /4 PFH DRYWALL SCREW STEEL 12 WEATHERSTRIP QEBD650 Q-LON 18 3.983" X 4.0" HINGE MIN 0.098" THICK STEEL 19 SILLKEY PC/ASA 22 DEADBOLT STRIKE PLATE STEEL 23 LATCH STRIKE PLATE STEEL 24 9 X 5/8" PFH WS STEEL 25 OUTSWING HIGH -DAM THRESHOLD ALUMINUM W/ COMPOSITE SUBSTRATE ALUM./ COMP. 26 9 X 1.0" PFH WS STEEL 27 OUTSWING THRESHOLD ALUMINUM W/ COMPOSITE SUBSTRATE ALUM./ COMP. 40 DOOR PANEL -SEE DOOR PANEL DETAIL SHEET FOR CONSTRUCTION DETAILS 64 8 X 7' PFH WOOD SCREW STEEL REQUIRED INSPECTION SEQUENCE BP# BUILDING PERMIT Min Max Inspection Description Footer / Setback Stemwall Foundation / Form Board Survey Slab / Mono Slab Pre our Lintel / Tie Beam / Fill / Down Cell Sheathing — Walls Sheathing — Roof Roof Dry In Frame Insulation Rough In Firewall Screw Pattern Drywall / Sheetrock Lath Inspection Final Solar Final Firewall Final Roof Final Stucco / Siding Insulation Final Final Utility Building Final Door Final Window Final Screen Room Final Pool Screen Enclosure Final Single Family Residence Final Building Other Address: /4-1 ,Q/,,L lam./ ELECTRICAL PERMIT Min Max Inspection Description Electric Underground Footer / Slab Steel Bond ' Electric Rough T.U.G. ' Pre -Power Final Electric Final Min Max Ins ection Descrl tion Plumbing Underground Plumbing Sewer Plumbing Tub Set Plumbing Final MECHANICAL PERMIT Min Max Inspection Description Mechanical Rough Mechanical Final PI UNIBINIG) GAS PERN11T- Min Max Inspection Description Gas Underground Gas Rough Gas Final REVISED: June 2014