Loading...
335, 339, 343, 347, 351, 355, 359 Merry Brook Cir #17-2264- new townhomesCOUNTY OF SEMINOLE IMPACT FEE STATEMENT STATEMENT NUMBER: 17100005 BUILDING APPLICATION #: 17-10000586 BUILDING PERMIT NUMBER: 17-10000586 DATE: August 17, 2017 3`1'),Io ; _�- UNIT ADDRESS: TAYLOR MORRISON OF FL INC 2600 LAKE LUCIEN DR x$350 TRAFFIC ZONE:022 JURISDICTION: SEC: TWP: RNG: SUF: PARCEL: SUBDIVISION: TRACT: PLAT BOOK: PLAT BOOK PAGE: BLOCK: LOT: OWNER NAME: ADDRESS: APPLICANT NAME: ADDRESS: LAND USE: TYPE USE: WORK DESCRIPTION: CITY-SANFORD SPECIAL NOTES: 335 MERRY BROOK CIRCLE THORNBROOKE PH 5 LOT 257 TOWNHOME ------------------------------------------------------------------------------- F'EE BENEFIT RATE UNIT CALC UNIT TOTAL DUE TYPE -------------------------------------------------------------------------------- DIST SCHED RATE UNITS TYPE ROADS-ARTERIALS CO -WIDE ORD Condominium* 379.00 '1.000 dwl unit 379.00 ROADS -COLLECTORS N/A Condominium* .00 .000 dwl unit .00 FIRE RESCUE N/A .00 LIBRARY CO -WIDE ORD Condominium* 54.00 1.000 dw1 unit 54.00 SCHOOLS CO -WIDE ORD 2,450.00 1.000 dwl unit 2,450.00 Amultifamily PARK N/A .00 LAW ENFORCE N/A .00 DRAINAGE N/A .00 AMOUNT DUE 2,883.00 STATEMENT RECEIVED BY: ��(� G� (`L1t SIGNATUR (PLEASE PRINT NAME) DATE : � i NOTE TO RECEIVING SIGNATORY/APPLICANT: FAILURE TO NOTIFY OWNER AND ENSURE TIMELY PAYMENT MAY RESULT IN YOUR LIABILITY FOR THE FEE. *** DISTRIBUTION: 1 -BLDG DEPT 3 -APPLICANT 2 -FINANCE 4 -LAND MANAGEMENT **NOTE** PERSONS ARE ADVISED THAT TI[IS IS A STATEMENT OF' FEES DUE UNDER THE SEMINOLE COUNTY ROAD, FIRE/RESCUE, LIBRARY AND/OR EDUCATIONAL ISSUANCE OF A BUILDING PERMIT. PERSONS ARE ALSO ADVISED THAT ANY RIGHTS OF THE APPLICANT, OR OWNER, TO APPEAL THE CALCULATION OF ANY OF THE ABOVE MENTIONED IMPACT FEES MUST BE EXERCISED BY FILING A WRITTEN REQUEST WITHIN 45 CALENDAR DAYS OF THE RECEIVING SIGNATURE DATE ABOVE, BUT NOT LATER THAN CERTIFICATE OF OCCUPANCY OR OCCUPANCY. THE REQUEST FOR REVIEW MUST MEET THE REQ=UIREMENTS OF THE COUNTY LAND DEVELOPMENT CODE. COPIES OF RULES GOVERNING APPEALS MAY BE PICKED UP, OR REQUESTED, FROM THE PLAN IMPLEMENTATION OFFICE: 1101 EAST FIRST STREET, SANFORD FL, 32771; 407-665-7356. PAYMENT SHOULD BE MADE TO: SEMINOLE COUNTY OR CITY OF SANFORD BUILDING DEPARTMENT 1101 EAST FIRST STREET SANFORD, FL 32771 PAYMENT SHOULD BE BY CHECK OR MONEY ORDER, AND SHOULD REFERENCE THE COUNTY BUILDING PERMIT NUMBER AT THE TOP LEFT OF'THIS STATEMENT. ***THIS STATEMENT IS NO LONGER VALID IF A BUILDING PERMIT IS NOT*** ISSUED WITHIN 60 CALENDAR DAYS OF THE RECEIVING SIGNATURE DATE ABOVE * DETAIL OF CALCULATION AVAILABLE UPON REQUEST. CALL 407-665-7356. -_l %1 -------------------------' -----------I r --------------------------------____-_-___-_-._---______ _ I ----__ ____,-_---_ _________________-_-_' ...____________________-_---__.__________________-______-_.-----___._..___-..__--___-__________-______.-_-_-_.__-____________-_-____________J---_.____, i I ; 1 1 , _. - , . - �• ...._�<, r w w—w— �—w —p—.ter=.-v `."°'-ct. • w—r�—M—r.--_G_._..�..-w—�r--a---q�--Y---a�_..:..w�s•••� ,a. :'. e--m—w—r—o--•--a--s—w • , —��d �.. .�.�-cMa�ar_�l '_ q' `� `—a—w--�--�J—w—�—r—Y---1----•w�- I 1 , w T .I .T �•-------� _� .,.. - - iii C _._._._..___..__.__._-_._._.__ _ CEDAR __ - J) WHITE C-_-_ - SINGLE HYDRANT TEST I_ k — _....._ _..._ _ . ............... _.. _....._ 1 ---. STATIC- 66 PSI _- _._ - - _.._..._ .. _... - ... __ _... _._.._... --- -------------------------- --- --- �.__ __—_ �_ __--- —_—_ _� _ --Lr._ __:.. _ __ __.. _ __ _� _ __ _----_. _____—_—_ — __ _— _— _—_�._--.--_._.-----_-------_--.-____---_._._.•.�__._..-.._._..-_..._-------------F— S h_ ; /RESIDIJAL 56-PSY FLOW = 1010 GPM - EXISTING 10 PVC C900 DR -18 VATER MAIN f-• __tea --w—w _ �--�I—�w—y --w-_.•_w----a —_r --r w—w—w----w r—w—u—w—�--n--a--s----r- --10 _ w—a r --r -,—•r •-j •`� — S 50 LTD , . � ..---......: _ . �. .... ... ,r -. -.--a---- .. C � ... . �----.- �----.-',--,. - ,- WILK X fCIR U kIN -MAIN .r— IN 9 . A G ":a • ' ; • DAUB �E"CNEGK •DET 'C OR'• � .. . _ .. ..-•-- TEE ___---- ... .._. - -- .-------"------1-- ___.... __ .,__..,_-. W ..___._•._... __.. ____ ___..._ - •- ___.. I TYPICAL FIRS SPRINKLER DOUBLE CHECK DETECTOR TYPICALrFIRE SPRINKLER FIRE SPRINKLER BACKFLOW PREVENTER W/ 1 I I i TYPICAL FIRE SPRINKLER RISER, SEE UNIT PLANS BACKFLOW PREVENTER W/ RISER, SEE UNIT PLANS RISER. SEE UNIT L----------------- GATE VALVES FOR FIRE, - I - --- i ¢ ----- RISE�_SEE_ 2LAI _ vv F �(BY-OTHERS.)----- ----------- -----�_- _F4R_DTAII� (wFs#85Q33) fiATE (YLOTHER�R-�IRE;�---------�--FOR-DETPIL, (WAFS #85832) .. _--_--rPLANS-FJR DETAIt -. T- —,----'--------- I FO� DE AIL ( 196) I �r (WAFS #7893)--I- - S #84 W R R B R R W W R•.--- R B B R R W W R R B B R R W I W R B B R W W R B B R W Willow Redwood Redwood Bircl Birch Redwood Redwood Willow Willow Redwood Redwood Birch Birch Redwood Redwood Willow Willow Redwood Redwood Birch Birch Redwood Redwood Willow I ± Willow Redwood Birch Birch Redwood Willow Willow Redwood Birch Birch Redwood Willow 25625 S 25425,E 252 251250 249 248 247 246 245 244 243 242 241 L�.)_, I� j E IST NG � ►� E IS INC EX STI G � 1 I $1 CPVC I FIRE SPRINKLER RISER 1 - 77 76 75 74 73 72 71 70 1 9 8 6 5 4 2 1 0 9 S8 SEE UNIT PLA<VS (TYP,) I h' FOR DETAIL ; 1'¢' CPVC UjL IRE WATE ' CPVC j 1'�' CPw FIRE WATER i i i i i , �' OTHES,) 11LINE (BY OTHERS,) t=t (•(TYR) . I iICAO 1w I w 4 ., w; w IVt GP -VC w; w 1 ,.. w WAAF.S• w I w 1 'CPVC w; w I q w I w w w 1 ; r u w w w 1 w IV CPVC ww w w 1W. (TYPICAL) Q a S ti S Ei a S S S ai a 142'-0 i WAF 8. �,i; r~i1i` 14 f y TE 2 OCTAVE METER POINT OF 18T=0 'I''i i I�``•I;'' I,_ I POINT,OF Bf=1—� CONNECTION. , BY OTHERS, `T --•_- _ 1 METER FOR FIRE & .- - -- - - L� METER FOR DOMESTIC, 8 PVC C900 DR -18 WATER MAIN I lr1 P�(C-�g�0 DR -18 GRATER G64 , '2' A W,W,A, VALVE: — 2 POLY I � 2 A,VW,A, VALVE. Y OTHERS (BY OTHERS) (BY OTHERS.) 1' METER FOR FIRE &' (CIRCULATING MAIN) I �� of I r 1 METER FOR DOMESTIC, (BY OTHERS)\ METER FOR DOMESTIC, SERVICE I (BY OTHERS.) \ 1 SEE DETAIL. I TYPIC L, METER FOR DOMESTIC. II _ 1 RoINroF - + ..- - ----I -► - _ -- - .__ T ------(BY�OTHERS) - -- -- -- -- - - +- - -- - --I-J - -_ _ TY I -'- -- -- -- - - - - - - - -- -- - '� I -�--- - - �- - --�-� -- -�- -- - - IRVICE -- -.. �,�` _ - - TL(BY DTH RS) - - -- --I -I- -- - _ 1 I _ (BY O_}HES) I PYPICAL-FIRE-SPRINKLER i RISEf�SEE-UNIT-PLANS ' 1 r ' IV CPVC lis' CPVC 1'�� CPVC M FOR DETAIL. (TYPJ (TYP) (WAFS #85826) - 1 (WAFS #85828) (WAFS #85II27) TYPJ i I -- — I �) TYPICA�E SPRINKLER -71T W W --J RISER SEE UNIT PLANS 1 2 i 0 U,~ ` ME I ro 2 7 1 willow FOR ETAIL, - - - - -- - V) ...� . Will Willow I , ) I - - - -- - - - - 1 f _ (J) s DO P S ii ; -- _ _ i CAIT�. 'v) _ R L u , _... A/ I dwoo R - (BYO HERS) 2 7 Redwood 1 �-� > 29 �I.r...a ; Redwood { { - -;------- I B CLUBHOUSE v J 2K'`9 R R 208 273 NO AIS - f r', Birch � 1 ' CP Red A Redwood � \1 1 CPVC` F_._. VC I i 1 1 1 J) - B �CllF ;'rJ) B __�� (TYPJ —_—_ I �.%� -�± 1..J - jIYPICAL FIRE PRINKI�ER W - o®rr a I Birch Birch 267 Iv CPVQ 2 > 4 Birch ISER: SEE UNI PLANS - -=: - - _- �}- - OR DETAIL, wiuow "� �'� I III' CPVC U - �-a Urn � � � z w �- R �` oc U 1 , CPUC 2' OCT VE, METER U7 6'-0 �-�- BY T RS,, V `"'Redwood R '"� Q 1 I U) R wood Redwood _ 3. G 4_y _ _ - Redwood 11 A,W,W,A, , LVE I W R \, �✓� E.I (BY DTH' RS,) 2 7 Willow _._ _._- __ _/ I i Red od Redwood (n, W A F.S• _. _ I Birch I ( POINT of E POINT of l I 2 PVC CONNECTION. ® CONNECTION.; 6, W 264 ® 39'-0 i 21 WILKINS 950XL;TD ` I WAFS B U' i j METER FOR DOMESTIC, U) _ _ r I LE CHECK DETECTOR Birch f j I 1 illow Willow ( #1:028) 3 1 POINT OF, I I- TYPICAL, 1 seRVK;E ! BF2 HFI (BY OTHERS) PVC INT IV) BCI�FLOW PREVENTER W � I (BY OTHERS) — ,_•_.__ a (WAFS #85825) O �j _ 0 W _ 2 PVCF, G T VAL ES FOR FIRE, .-. _-- -- -- -- _- R Io -D° I E 124' c21 i 34'-0 � :. �� 0 � �� z wiuow ($Y OTHERS) -�__ I 2' A,W,!V A, VALVE, ' I (WAFS 985831) (WAFS #85830) Redwopd (BY jOTHERS,) uGs W � W / I 0 R ` W j BTYP fC S) 1 I2 OCTAVE MMTER r w Ldp 0 E Redwood -+- ' U) Willow M F- T-- rr r Willow A.W W A, VALVE, BY OTHE w V .. � �, w.. � I willow — ._ (BY OTHERS) .., . r' u) R L� W R 3 o 1 1 Rp C'J (�' �« B 2' WILKIN 950X� TD A' 1 �, „ Y THERS. i 217 . � P 204 N I 0 TR �` � DOUBLE CHEC DETECTOR 11.2' PVC POINT OF I' _ o _ BACKFLOW PR VENT R W/ I 34'-0 cls RAE 1 I s Redwood � v 3 ¢ �.. Redwood I - Birch i'"`' _r GATE VALVE FOR FIRE - MOST REMOTE j _j LJ,.. w I )o -o^ R I YDRAOLICA1�Y �' i R �± Q CJ R 0 i 9 ; (BY OTHERS,) W- CALCOLATED as Redwood (n Redwood 126 Ul Redwood 1 I lye' CPVC - 1 ! - - - - - - - - - - - - - - - - _. _ -- - - - - _ .__. - - - - _ _.. i V) 1 - _ _... __ I _ _� Willow i' W .8. ; N BUIL � DINQ. - - `1 ,IICPVC,Tn -- - ,yam (WAFS #181 8)- -' OF 1 ( ?� B B 200 010 T� 198W ,, � N. EXIS IN�11 a Birch Birch � —p� Willow Redwood I _ ; 2` WILKINS 950XLTDReviewed By: f I TB B B i Pk'CPVC TYPICAL FIRE SPRINKLER DOUBLE -CHECK -DETECTOR TYPICAL FIRE SPRINKLER TYPICAL FIRE SPRINkQR 1 j� e `� Birch Birch 11 0 BACKFLOW PREVENTER W/ B128ID'•D, Tim l'e s� O BH .!. Izv , METER FOR DOMESTIC, , v) U) I (TYP,) RISER, SEE UNIT PLANS -. ��'�'------GATE-VALVE-S-FOR-FIRE; RISER,_ SEE UNIT PLANS _. RISER-SEE__UNI-UPLANS TYPICAL, I r I Birch v) ' --FQR--DE-TAI --r---- FOR -AE -TAIL. i - ; r--�---FOR DETAIL, _ --- -' -- r Q f-'- ` - (BY -OTHERS)- — U) 10�-0: v , I r (WAFS #85829) (WAFS #84194) (WAFS /k84191) i CPVC __ _ (BY ,OTHERS) I R R �08 �•.'" I I I B �'r i �a2'-o i> I _ 129 I ; ��°f r 4 1. Redwood Redwood w W R R B R R W W R R B B R R W W R R B R R W _ I I Birch TR R R 20x_7 = Inc,u Willow Redwood Redwood Birc Birch Redwood Redwood Willow Willow Redwood Redwood Birch Birch Redwood Redwood Willow Willow Redwood Redwood Birch Redwood Redwood Willow R � I ,r) ✓✓�. r^ '-"" Redwood Redwood [� , �- j "- pD ` '� 130 I - - ' 97 196195 _�.9 193 192 191190 146 1451.4414 14214114'01 9 138 713 135. 34133132 Redwood (n • 'POLY I W W "' EXISTING E I ST N G 1 ' cPvc (YJIRTHERS) 'I METER FOR DOMESTIC, I I Willow Willow 1.fI 1 `CPVC 11'-o W 13 \A"LFFICE TI�(�ICAL TYPICAL. (TYPJ Willow j I` CPVC 11 ° _ _ (BY OTHERS) 1 TV By I 11'- 4 q (TYPJ 4 I 1 11 CPvc TYPICAL FIRE SPRINKLER 1 `CPvc o o lY�' CPvc 11-0 11'-0 1 (TYR) RISER: SEE UNIT PLANS (TYPO w I w w , w I w w; w i w w ; w w ; w w; w , w WAF•8- I w w I w �, w; w ' 4 1$, CPV �' 1 '-_CPVC r. S (TYR) . ' l C�P.) r r <.l�e C2VC , 4 c c _ EOR -DETAIL I S , 1$7,'- L1�� S .I ', —LI �i,% '-0 ,I, 5 I POINT OF I 172`-0 5\I T, �I I� ♦ j i3 L �'!1 a ,.J ;'L ( — -- OCI V�-METER- . ,•. -- I i_ SID I WAF S. I . . f POINT OF l � � ' I I CONNECTION. M l 'H,y � p ,. ,.-� di-201�201 0 40 80 1 I O "cu STREET A ` I 3 , I _—�-� - 8 PVC-C900-DR=I8-WATER-MAIN __ ,.- - 8'IPVC-C900-b� I8-WAT -------------------- --------------------_____ —--2--A,W;W N VAL-=VE ---- (CIRCULATING MAIN) 2' A,W,W.A, VALVE, C190 PANT OF' METER FOR DOMESTIC, (BY OTHERS.) clBz _ 1 _-'---__-_-- (BY ---._ __-_-_.:_ SERVICE 2' WILKINS 950XLTD - - ---- --- _ . ---- -- ----- _ _ . TYPICAL: _ SCA _ ._ --- ----- - - - _ __ ___ - - . .. _-__ _ -- _ -(BY OTHERS) -----------..___ __ ._ PaINT of ---- ..._..._._.___DOUBLE CHECK DETECTOR -------------- -- - -- - _---• -'--- - ----__ _ _-------- - ------ `._-- ? '; LE 1' = 40' SERVICE BACKFLOW PREVENTER W/ 9 I �',I0iN ' GATE VALVES FOR FIRE. (BY OTHERS.) IiVIPOFLTANl' OtiVNER IINFORNIATIONG'RAPFIIC ELENiENr!S NC)TE THIS DRAWING IS BASE➢ ON THE OWNER'S ACCEPTANCE OF THE CURRENTLY ADOPTED FIRE SPRINKLER CONSTRUCTION DRAWINGS AND SHOP DRAWINGS MAY INCLUDE WATER SUPPLY INFORMATION BACKGROUND DRAWINGS OR GRAPHICS BORROWED FROM THE ARCHITECTURAL CIVIL DESIGN CRITERIA SYSTEM / DESIGNAREA I HAZARD CLASS I OF SPRINKLERS IN DESIGN AREA MINIMUM DENSITY DESIGN AREA S.F, PSI REQ'D @ BASR GPM REQ'D @ BASR PSI REWD @ TEST GPM REWD @ TEST ELEVATION @ HIGHEST SPRINKLER HOSE INSIDE/OUTSIDE DOMESTIC DEMAND SPRINKLERS SPACING ISYMBOLI MAXIMUM I MINIMUM COMMENTS ENTS r--QUANTITY--i SPRINKLERS SYMB ACTUAL EDITION (EITHER STATE OR LOCAL) OF NFPA 25 AS THE APPLICABLE STANDARD FOR STRUCTURAL, OR MEP DRAWINGS. THESE REFERENCE BACKGROUND ELEMENTS ARE FOR 4TH SIZE, GPM @ PSI THE INSPECTION, rESTINGAND MAINTENANCE OF WATER BASED FIRE PROTECTION GENERAL INFORMATION OR CONTEXT ONLY AND THE FIRE SPRINKLER ENGINEER DOES 65 PSI MODEL SYSTEMS. PER SECTIDN 4,1, THE RESPONSIBILITY FOR PROPERLY MAINTAINING A NOT ACCEPT ANY RESPONSIBILITY FGR THESE ELEMENTS. THE FIRE SPRINKLER RESIDUAL PRESSURE 55 PSI WATER BASED FIRE PROTECTION SYSTEM SHALL BE THAT OF THE OWNER, IF THE ENGINEER IS ONLY RESPONSIBLE FOR THOSE PORTIONS OF THE FIRE SPRINKLER 10/11/17 I FLOW IN GPM BUILDING OWNER HAS NOT RECEIVED A COPY OF THIS PAMPHLET AND/OR IS NUT DRAWINGS DEPICTING FIRE SPRINKLER SCOPES OF WORK. REFER TO APPROVED TIME OF TEST 8±00 AM FAMILIAR WITH THE OPERATION AND MAINTENANCE OF THIS SYSTEM, PLEASE CONTACT ARCHITECTURAL, STRUCTURAL, MEP OR CIVIL DRAWINGS FOR AUTHORITATIVE NUMBER OF PORTS FLOWED I THE NEAREST OFFICE OF WAYNE AUTOMATIC FIRE SPRINKLERS, INC. EXPRESSIONS OF BACKGROUND INFORMATION THAT MAY DE UTILIZED IN FIRE I HYDRANT LOCATION OR NUMBER TEST HYDRANT LOCATED ON WHITE CEDAR ROAD CONCORD, NC 28027-6977 SPRINKLER DRAWINGS OR DETAILS PHONE (239) 433-3030 PHONE: (704) 7B2-3032 SC SPRINKLER 1118 FAX: (239) 433-3263 FAX: (704) 795-6838 SC ALARM: 3385 CPVC COiv1PATIBIL,I1'Y NOTICE: CPVC FIRE SPRINKLER PIPING SYSTEMS HAVE BEEN USED SUCCESSFULLY FOR MORE THAN 20 YEARS IN NEW CONSTRUCTION, RE -PIPE AND REPAIR. CPVC PRODUCTS ARE IDEALLY SUITED FUR THESE APPLICATIONS DUE TO THEIR OUTSTANDING CORROSION RESISTANCE. OCCASIONALLY, HOWEVER, CPVC CAN BE DAMAGED BY CONTACT WITH CHEMICALS FOUND IN SOME CONSTRUCTION MATERIALS (IE, SOME WIRES, FLUX, PETROLEUM BASED PRODUCTS, ETC.) AND ANCILLARY PRODUCTS SUCH AS THREAD SEALANTS, LEAK DETECTORS, FIRESTOPS, ETC. ANY PRODUCT THAT COMES IN CONTACT WITH CPVC SPRINKLER PIPE MUST BE EVALUATED IN ACCORDANCE WITH THE SYSTEM COMPATIBILITY PROGRAM AS FOUND AT WWW.SYSTEMCOMPATIBLE.CUM L Q COP YF?ICG1-CIII m TOTAL PER FLOOR ALL DOCUMENTS, INCLUDING ORIGINAL DRAWINGS, SPECIFICATIONS, FIELD NOTES, Lr) ESTIMATES AND DATA, INCLUDING COMPUTER PROGRAMS PURSUANT TO THIS PROJECT ARE AND`WILL REMAIN THE PROPERTY OF WAYNE AUTOMATIC FIRE SPRINKLERS, INC. 71: AS INSTRUMENTS OF SERVICE. THEY ARE NOT INTENDED, NOR REPRESENTED 'TO ri To BE SUITABLE FUR RE -USE BY THE CLIENT, OR OTHERS, ON EXTENSION OF THIS PROJECT, OR FOR ANY OTHER PROJECT, ANY REUSE, OR ADAPTATION OF THE NFORMATIUN CONTAINED HEREIN, WITHOUT SPECIFIC WRITTEN PERMISSION FROM WAFS WILL BE AT THE CLIENTS SOLE RISK, WITHOUT LIABILITY,OR LEGAL EXPOSURE TO H WAFS, Atli)WILL ENTITLE WAFS TO FURTHER COMPENSATION AT RATES TO BE I' O AGREED ON BETWEEN WAFS AND THE CLIENT. THE CLIENT SHALL ALSO INDEMNIFY AND HOLD WAFS HARMLESS FROM ANY AND ALL CLAIMS, DAMAGES, LOSSES AND ('r1 EXPENSES, INCLUDING ATTORNEYS FEES RESULTING FROM ANY SUCH PERMISSIONS. DESIGN CRITERIA SYSTEM / DESIGNAREA I HAZARD CLASS I OF SPRINKLERS IN DESIGN AREA MINIMUM DENSITY DESIGN AREA S.F, PSI REQ'D @ BASR GPM REQ'D @ BASR PSI REWD @ TEST GPM REWD @ TEST ELEVATION @ HIGHEST SPRINKLER HOSE INSIDE/OUTSIDE DOMESTIC DEMAND SPRINKLERS SPACING ISYMBOLI MAXIMUM I MINIMUM COMMENTS ENTS r--QUANTITY--i SPRINKLERS SYMB ACTUAL DROUGHT OR EXTRAPOLATED (AS REQ'D BY AHJ) FIRE PUMP 4TH SIZE, GPM @ PSI SIZE STATIC PRESSURE 65 PSI MODEL HYDRANT ELEV, 2' RESIDUAL PRESSURE 55 PSI JACKSONVILLE, FL 32256-2745 DATE OF TEST 10/11/17 I FLOW IN GPM 1000 GPM PHONE: (954) 917-3030 TIME OF TEST 8±00 AM PITOT READING 36 PSI NUMBER OF PORTS FLOWED I TEST PROVIDED BY WAYNE AUTOMATIC FIRE SPRINKLERS, INC, HYDRANT LOCATION OR NUMBER TEST HYDRANT LOCATED ON WHITE CEDAR ROAD DESIGN CRITERIA SYSTEM / DESIGNAREA I HAZARD CLASS I OF SPRINKLERS IN DESIGN AREA MINIMUM DENSITY DESIGN AREA S.F, PSI REQ'D @ BASR GPM REQ'D @ BASR PSI REWD @ TEST GPM REWD @ TEST ELEVATION @ HIGHEST SPRINKLER HOSE INSIDE/OUTSIDE DOMESTIC DEMAND SPRINKLERS SPACING ISYMBOLI MAXIMUM I MINIMUM COMMENTS ENTS r--QUANTITY--i SPRINKLERS SYMB IST 2ND 3RD 4TH SIN SIZE K TEMF MODEL 71 POMPANO BEACH, FL 11325 0(STRIBLTTION AVE WEST 3226 CHERRY PALM DRIVE 3121 NW 15TH TERRACE JACKSONVILLE, FL 32256-2745 TAMPA, FL 33619-8337 POMPANO BEACH. FL 33054-1406 PHONE; (904) 268-3030 PHONE: (813) 630-0303 PHONE: (954) 917-3030 FAX; (904) 268-0724 FAX: (813) 630-0312 FAX: (954) 917-B424 FT. MYERS. FL CONCORO• NC STATE LICENSES: 4663 LAREDO AVE 4370 MOTORSPORT DRIVE NC SPRINKLER 29745 FT. MYERS, FL 33905-4924 CONCORD, NC 28027-6977 NC ALARM: 29222 SP LV PHONE (239) 433-3030 PHONE: (704) 7B2-3032 SC SPRINKLER 1118 FAX: (239) 433-3263 FAX: (704) 795-6838 SC ALARM: 3385 TOTAL PER FLOOR TOTAL THIS SHEET DATE SUBMITTALS 04/17/17 Q.A. REVIEW\ BY MPF N0, I DATE I REVISIONS BY AAJ 12/15/16 1 BACKFLOW WAS MOVED. MPF (UNDERGROUND) THORNBR00 E T K OWNHOMES WHITE CEDAR ROAD SANFORD FL 32771 WAYNE TAYLOR MORRISON HOMES 151 SOUTHHALL LANE, SUITE 200 Automatic Firc Sprinl(Iprs Inc MAITLAND, FL 32751 SHEET TITLE- I MAIN OFFICE -- ORLANDO, FLORIDA 222 CAPITOL COURT OCOEE. FLORIDA 34761 PHONE: (407) 656-3030 FAX: (407) 856-8028 JACKSONVLLE, FL TAMPA, FL 71 POMPANO BEACH, FL 11325 0(STRIBLTTION AVE WEST 3226 CHERRY PALM DRIVE 3121 NW 15TH TERRACE JACKSONVILLE, FL 32256-2745 TAMPA, FL 33619-8337 POMPANO BEACH. FL 33054-1406 PHONE; (904) 268-3030 PHONE: (813) 630-0303 PHONE: (954) 917-3030 FAX; (904) 268-0724 FAX: (813) 630-0312 FAX: (954) 917-B424 FT. MYERS. FL CONCORO• NC STATE LICENSES: 4663 LAREDO AVE 4370 MOTORSPORT DRIVE NC SPRINKLER 29745 FT. MYERS, FL 33905-4924 CONCORD, NC 28027-6977 NC ALARM: 29222 SP LV PHONE (239) 433-3030 PHONE: (704) 7B2-3032 SC SPRINKLER 1118 FAX: (239) 433-3263 FAX: (704) 795-6838 SC ALARM: 3385 SHEET TITLE- FIRE PROTECTION SITE PLAN DRAWN BY, MICKEY FERGUSON TOTAL A/S- (SEE FLOOR PLANS) DATE, NOVEMBER 7, 2017 W CITY OF SANFORD CONTRACT 11 86022 CENTER OF TILE JOB7 YES NO CENTER ON FIXTURES JOB? Q YES NO SHEET L -FPS, 1 CONSTRUCTION TYPE, v -e OCCUPANCY R-3 BIRCH SPIGOT 0: Garage F--------------------� I �e max\ 1 1'-0' I BR j� ---------------- I U I In I U REDWOOD UNIT SPIGOT LOCATION DETAIL 2' 1' 0 41 8/ 1/4/1 SCALE 1/4' = V Garage --------------------------------------11 ' I I soh I 1'-0 ------------------------------��-1-- L---..—_._----------_-� I U WILLOW UNIT SPIGOT LOCATION DETAIL 1/4' = 11-0' FIRE SPRINKLER SPIGOT DETAIL � SCALE! 1/2" = 1' Autwrotw Fin SW*"", kom INIPORTANI OWI\TER INF'ORMATTON GF2AE'PIICS EL,�,MENTS NO I'E: THIS DRAWING IS BASED ON THE OWNER'S ACCEPTANCE OF THE CURRENTLY ADOPTED FIRE SPRINKLER CONSTRUCTION DRAWINGS AND SHOP DRAWINGS MAY INCLUDE BACKGROUND DRAWINGS GRAPHICS BURROWED FROM THE ARCHITECTURAL CIVIL, EDITION (EITHER STATE OR LOCAL) OF NFPA 25 AS THE APPLICABLE STANDARD FOR STRUCTURAL, OR MEP DRAWINGS. THESE REFERENCE BACKGROUND ELEMENTS ARE FOR THE INSPECTION, TESTINGAND MAINTENANCE OF WATER BASED FIRE PROTECTION GENERAL 1NFORMATION OR CONTEXT ONLY AND THE FIRE SPRINKLER ENGINEER DOES SYSTEMS, PER SECTION 4.1, THE RESPONSIBILITY FOR PROPERLY MAINTAINING A NOT ACCEPT ANY RESPONSIBILITY FOR THESE ELEMENTS. THE FIRE SPRINKLER WATER BASED FIRE PROTECTION SYSTEM SHALL BE THAT OF THE OWNER, IF THE ENGINEER IS ONLY RESPONSIBLE FOR THOSE PORTIONS OF THE FIRE SPRINKLER BUILDING OWNER HAS NOT RECEIVED A COPY OF THIS PAMPHLET AND/OR IS NOT DRAWINGS DEPICTING FIRE SPRINKLER SCOPES OF WORK, REFER TO APPROVED c' TA AN F THIS SYSTEM PLEASE CONTACT FAMILIAR WITH THE OPERATION AND MAINTENANCE 0 1 STRUCTURAL, MEP DR CIVIL DRA`dINGS FOR AUTHORITATIVE ARCHITECTURAL S EXPRESSIONS OF BACKGROUND INFORMATION THAT MAYBE UTILIZED IN FIRE THE NEAREST OFFICE DF WAYNE AUTOMATIC FIRE SPRINKLERS, INC, SPRINKLER DRAWINGS OR DETAILS 1000 GPM CPVC CONIPATIBILYPY NOTICE; 8:00 AM CPVC FIRE SPRINKLER PIPING SYSTEMS HAVE BEEN USED SUCCESSFULLY FOR MORE 36 PSI THAN PO YEARS IN NEW CONSTRUCTION, RE -PIPE AND REPAIR. CPVC PRODUCTS ARE 1 IDEALLY SUITED FOR THESE APPLICATIONS DUE TO THEIR OUTSTANDING CORROSION RESISTANCE. OCCASIONALLY, HOWEVER, CPVC CAN BE DAMAGED BY CONTACT WITHCHEMICALS FOUND IN SOME CONSTRUCTION MATERIALS (IE, SOME WIRES, FLUX, PETROLEUM BASED PRODUCTS, ETC,) AND ANCILLARY PRODUCTS SUCH AS THREAD SEALANTS, LEAK DETECTORS, FIRESTOPS, ETC, ANY PRODUCT THAT COMES IN PSI REQ'D R TEST CONTACT WITH CPVC SPRINKLER PIPE MUST BE EVALUATED IN ACCORDANCE WITH THE SYSTEM COMPATIBILITY PROGRAM AS FOUND AT WWW.SYSTEMCOMPATIBLE,CUM CORYRICI -1 1.11 ALL DOCUMENTS, INCLUDINGORIGINAL DRAWINGS, SPECIFICATIONS, FIELD NOTES, ESTIMATES AND DATA, INCLUDING COMPUTER PROGRAMS PURSUANT TO THIS PROJECT ELEVATION 2 HIGHEST SPRINKLER ARE AND WILL REMAIN THE PROPERTY OF WAYNE AUTOMATIC FIRE SPRINKLERS, INC. (WAFS) AS INSTRUMENTS OF SERVICE. THEY ARE NOT INTENDED, NOR REPRESENTED TO BE SUITABLE FOR REUSE BY THE CLIENT, OR OTHERS, ON EXTENSION OF THIS PROJECT, OR FOR ANY OTHER PROJECT. ANY REUSE, OR ADAPTATION OF THE NFORMATION CONTAINED HEREIN, WITHOUT SPECIFIC WRITTEN PERMISSION FRUM WAFS DOMESTIC DOMESTIC DEMAND WILL BE AT THE CLIENTS SOLE RISK, WITHOUT LIABILITY, OR LEGAL EXPOSURE TO WAFS, AND WILL ENTITLE WAFS TO FURTHER COMPENSATION AT RATES TO BE AGREED ON BETWEEN WAFS AND THE CLIENT. THE CLIENT SHALL ALSO INDEMNIFY AND HOLD WAFS HARMLESS FROM ANY AND ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES, INCLUDING ATTORNEYS FEES RESULTING FROM ANY SUCH PERMISSIONS. WATER SUPPLY INFORMATION TEST PROVIDED BY WAYNE AUTOMATIC FIRE SPRINKLERS, INC, HYDRANT LOCATION OR I TEST HYDRANT LOCATED ON WHITE CEDAR ROAD NUMBER DESIGN CRITERIA • DESIGN AND INSTALLATION TO BE IN ACCORDANCE WITH 2010 EDITION OF NFPA 130, LOCAL PLUMBING CODE AND ALL APPLICABLE LOCAL AND STATE CODES. • ALL PLASTIC PIPE 3/4' THROUGH 2YE!" SHALL BE UL LISTED OR FM APPROVED CPVC MANUFACTURED IN ACCORDANCE WITH ASTM F442. • ALL PLASTIC FITTINGS SHALL BE UL LISTED OR FM APPROVED CPVC MANUFACTURED IN ACCORDANCE WITH ASTM F438, ASTM F439 OR ASTM F1970. * ALL CPVC PIPE AND FITTINGS SHALL BE ASSEMBLED USING 'ONE STEP" 500 CEMENT. `1 • ALL STEEL PIPE WILL BE SCHEDULE 40 HOT DIPPED GALVANIZED MANUFACTURED IN ACCORDANCE WITH ASTM A795 OR ASTM A-53. • ALL THREADED FITTINGS SHALL BE GALVANIZED MALLEABLE IRON CLASS 150 OR CLASS 300 AND SHALL BE MANUFACTURED IN ACCORDANCE WITH ANSI 816.3 AND ASTM A 153. • ALL GROOVED FITTINGS SHALL BE UL LISTED OR FM APPROVED AND MANUFACTURED IN ACCORDANCE WITH ASTM A-536 FOR DUCTILE IRON OR ASTM A-47 FOR MALLEABLE IRON. • BRASS PIPE AND FITTINGS WILL BE UTILIZED ONLY AS REQUIRED BY LOCAL WATER PURVEYOR. • WAFS TO PROVIDE CPVC COMPATIBLE AGAVE 14 GAUGE TRACING WIRE ON ALL UNDERGROUND PIPING. IM UNDERGROUND MAINS AND LEAD–INS SHALL BE FLUSHED PER FLOW RATES IN NFPA 24 PRIOR TO CONNECTING TO OVERHEAD PIPING. • ALL PIPING SHALL BE BURIED A MINIMUM OF 30 INCHES BELOW GRADE TO THE TOP OF THE PIPE PER WAFS COMPANY STANDARDS. IM ALL PIPING UNDER ROADWAYS SHALL BE BURIED A MINIMUM OF 36 INCHES BELOW GRADE TO THE TOP OF THE PIPE. MH ALL PIPING SHALL BE INSPECTED AND APPROVED BY PROPER AUTHORITIES PRIOR TO COVERING. • ALL PIPING SHALL BE TESTED AT 200 PSI FOR 2 HOURS PER WAFS STANDARDS. • VALVES SHALL NOT BE REQUIRED TO BE MONITORED PER FLORIDA BUILDING CODE 903.4 (1). • ALL PAINTING OF PIPE AS REQUIRED IS BY OTHERS. * WAFS TO PROVIDE ALL NECESSARY SIGNAGE INCLUDING BUT NOT LIMITED TO VALVES, HYDRAULIC PLACARDS, AND INSPECTION TAGS AS REQUIRED BY FS. 633. MT SEE CIVIL DRAWINGS FOR DETAILS OF PIPING PRIOR TO WAYNE AUTOMATIC'S POINT OF CONNECTION. • PER FLORIDA STATUTE 633.539, ALL UNDERGROUND FROM THE POINT OF SERVICE TO 1'-0' AFF SHALL BE INSTALLED BY ONE CLASS I, II OR V LICENSED CONTRACTOR. • ALL FERROUS PIPE AND FITTINGS SHALL BE EXTERNALLY WRAPPED AND COATED WITH A BITUMINOUS COATING. • CLEARANCES AROUND FIRE PROTECTION APPLIANCES SHALL BE PROVIDED AS REQUIRED BY LOCAL AUTHORITY. "fESEE F0 0-I-ING FROM SUPPLY SYSTEM / DESIGN AREA # ACTUAL DROUGHT OR EXTRAPOLATED (AS RELIT BY AHJ) FIRE PUMP 5 SIZE, GPM 8 PSI CDNTRACT # 86022 STATIC PRESSURE 65 PSI SOUTHERN VALVE IMPORT HYDRANT ELEV, 2' RESIDUAL PRESSURE 55 PSI DATE OF TEST 10/11/17 FLOV IN GPM 1000 GPM TIME OF TEST 8:00 AM PITOT READING 36 PSI NUMBER OF PORTS FLOWED 1 TEST PROVIDED BY WAYNE AUTOMATIC FIRE SPRINKLERS, INC, HYDRANT LOCATION OR I TEST HYDRANT LOCATED ON WHITE CEDAR ROAD NUMBER DESIGN CRITERIA • DESIGN AND INSTALLATION TO BE IN ACCORDANCE WITH 2010 EDITION OF NFPA 130, LOCAL PLUMBING CODE AND ALL APPLICABLE LOCAL AND STATE CODES. • ALL PLASTIC PIPE 3/4' THROUGH 2YE!" SHALL BE UL LISTED OR FM APPROVED CPVC MANUFACTURED IN ACCORDANCE WITH ASTM F442. • ALL PLASTIC FITTINGS SHALL BE UL LISTED OR FM APPROVED CPVC MANUFACTURED IN ACCORDANCE WITH ASTM F438, ASTM F439 OR ASTM F1970. * ALL CPVC PIPE AND FITTINGS SHALL BE ASSEMBLED USING 'ONE STEP" 500 CEMENT. `1 • ALL STEEL PIPE WILL BE SCHEDULE 40 HOT DIPPED GALVANIZED MANUFACTURED IN ACCORDANCE WITH ASTM A795 OR ASTM A-53. • ALL THREADED FITTINGS SHALL BE GALVANIZED MALLEABLE IRON CLASS 150 OR CLASS 300 AND SHALL BE MANUFACTURED IN ACCORDANCE WITH ANSI 816.3 AND ASTM A 153. • ALL GROOVED FITTINGS SHALL BE UL LISTED OR FM APPROVED AND MANUFACTURED IN ACCORDANCE WITH ASTM A-536 FOR DUCTILE IRON OR ASTM A-47 FOR MALLEABLE IRON. • BRASS PIPE AND FITTINGS WILL BE UTILIZED ONLY AS REQUIRED BY LOCAL WATER PURVEYOR. • WAFS TO PROVIDE CPVC COMPATIBLE AGAVE 14 GAUGE TRACING WIRE ON ALL UNDERGROUND PIPING. IM UNDERGROUND MAINS AND LEAD–INS SHALL BE FLUSHED PER FLOW RATES IN NFPA 24 PRIOR TO CONNECTING TO OVERHEAD PIPING. • ALL PIPING SHALL BE BURIED A MINIMUM OF 30 INCHES BELOW GRADE TO THE TOP OF THE PIPE PER WAFS COMPANY STANDARDS. IM ALL PIPING UNDER ROADWAYS SHALL BE BURIED A MINIMUM OF 36 INCHES BELOW GRADE TO THE TOP OF THE PIPE. MH ALL PIPING SHALL BE INSPECTED AND APPROVED BY PROPER AUTHORITIES PRIOR TO COVERING. • ALL PIPING SHALL BE TESTED AT 200 PSI FOR 2 HOURS PER WAFS STANDARDS. • VALVES SHALL NOT BE REQUIRED TO BE MONITORED PER FLORIDA BUILDING CODE 903.4 (1). • ALL PAINTING OF PIPE AS REQUIRED IS BY OTHERS. * WAFS TO PROVIDE ALL NECESSARY SIGNAGE INCLUDING BUT NOT LIMITED TO VALVES, HYDRAULIC PLACARDS, AND INSPECTION TAGS AS REQUIRED BY FS. 633. MT SEE CIVIL DRAWINGS FOR DETAILS OF PIPING PRIOR TO WAYNE AUTOMATIC'S POINT OF CONNECTION. • PER FLORIDA STATUTE 633.539, ALL UNDERGROUND FROM THE POINT OF SERVICE TO 1'-0' AFF SHALL BE INSTALLED BY ONE CLASS I, II OR V LICENSED CONTRACTOR. • ALL FERROUS PIPE AND FITTINGS SHALL BE EXTERNALLY WRAPPED AND COATED WITH A BITUMINOUS COATING. • CLEARANCES AROUND FIRE PROTECTION APPLIANCES SHALL BE PROVIDED AS REQUIRED BY LOCAL AUTHORITY. "fESEE F0 0-I-ING FROM SUPPLY SYSTEM / DESIGN AREA # WILKINS 3 SMITH COOPER 5 HAZARD CLASS CDNTRACT # 86022 ANVIL 6 ' 44 SOUTHERN VALVE IMPORT # OF SPRINKLERS IN DESIGN AREA WARD 10 MINIMUM DENSITY I DESIGN AREA S.F. PSI REQ'D 2 BASR i GPM REQ'D 2 BASR PSI REQ'D R TEST GPM REQ'D R TEST ELEVATION 2 HIGHEST SPRINKLER HOSE SIDE DOMESTIC DOMESTIC DEMAND SPRINKLERS SPACING PR IN IISYMBOLI MAXIMUM I MINIMUM COMMENTS A NFPA 19D 2010 TOWNHOME UNDERGROUND GENERAL NOTES V �' Ami SCALE! NONE Autometlo Fire SKWdsm Ino. r--QUANTITY--i SPRINKLERS 1ST 2ND 3RD 4TH K EM SIN SIZE MODEL TOTAL PER FLOOR AL THIS SHEET \J WILKINS 3 SMITH COOPER 5 PROVALUE CDNTRACT # 86022 ANVIL 6 ' 44 SOUTHERN VALVE IMPORT s 9 WARD 10 Y4' GALV, THREADED PLUG((,) Y4' BRONZE 3—WAY VALVE13 3Y2' WATER PRESSURE GAUGE14 —� Y4' X 3' GALV, NIPPLE 07 —� )/2' X Y4' GALV, BUSHING `4 TO THE OCTAVE METER, 2,X2'XpO---/ GALV, REDUCING TEE GI mry 14GA. COPPER LOCATING WIRE (AGAVOR ISHED GRADE MAX 900 FIRE MAIN CPVC FIRE MAIN =1" MAX ` LOCATING WIRE T— 6 NOTES: 1. PVC PIPE SHALL REQUIRE INSULATED METALLIC LOCATING WIRE (14 GAUGE COPPER AGAVE WIRE) CAPABLE OF DETECTION BY A CABLE LOCATOR AND SHALL BE BURIED DIRECTLY ABOVE THE CENTERLINE OF THE PIPE. 2. LOCATING WIRE SHALL TERMINATE AT THE TOP OF EACH VALVE BOX AND BE CAPABLE OF EXTENDING 12" ABOVE TOP OF BOX IN SUCH A MANNER AS TO NOT INTERFERE WITH VALVE OPERATION. 3. USE FGG/BM COMPATIBLE DUCT TAPE AS NECESSARY TO HOLD WIRE DIRECTLY ON THE TOP OF THE PIPE, TYPICAL LOCATING WIRE DETAIL E SCALE, NO SCALE —'7\"Vl;l9RN Automatb Fir* Sw**"r','"°. 00185N MANUFACTURER LIST 13 FPPI NIBCO UNITED BRASS u TYCO NIBCO I4 ARGCO SPEARS FPPI 12 TYCO VIKING ASHCROFT ANVIL VICTAULIC 15 (IN ACCORDANCE W/ SHURJOINT ANSI/ASTM A-53) 2' DOUBLE DETECTOR CHECK BACKFLOW PREVENTER W/ BUTTERBALL VALVES, (SEE MANUF, SPEC SHEET FOR FRICTION LOSS INFORMATION) 1 ti 2' GALV, + 1z GRV, COUPLING C i r 2' GALV, THREADED PLUG W,A,F,S, POINT OF CONNECTION, (:>_Nv"�e"NE Automat* Flrn Spr*Mw% kw. 00675N ■ REV, 2.0 DATE SUBMITTALSBY 04/17/17 QA REVIEW I MPF N0. I DATE REVISIONS A1�I XX/XX/XX I -- BY 2' X 3' GALV, NIPPLE 2' X 4' GALV, 10 THRD, X GRV, 2' X 3'-8' 1s GALV, SCH-40 2' GALV, Q 90' ELL 2' X 3' GALV, NIPPLE 2' CPVC 11 FEMALE ADAPTER — 2' X 1f , CPVC BUSHING — BFl 2' GALV, O TEE TO W CPVC SYSTEM 2" WILKINS 950XLTDABF DOUBLE DETECTOR CHECK BACKFLOW PREVENTER DETAIL SCALE! 1/2' = V (INSTALLED BY OTHERS.) \V WA" E Automatic Fire Sprinklers, Inc. MAIN OFFICE — ORLANDO, FLORIDA 222 CAPITOL COURT OCOEE. FLORIDA 34781 PHONE: (407) 655-3030 FAX: (407) 656-80213 JACKSONVILLE, FL TAMPA, FL POMPANO BEACH. FL IMIS DISTRIBUTION AVE WEST 3226 CHERRY PALM DRIVE 3121 NW 16TH TERRACE JACKSONVILLE, FL 32256-2745 TAMPA. FL 33619-8337 POMPANO BEACH, FL 33064-140E PHONE: (904) 268-3030 PHONE: (813) 630-0303 PHONE: (954) 917-3030 FAX: WC14) 268-0724 FAX: (813) 630-0312 FAX: (954) 917-9424 LJ FT. MYERS, FL CONCORD, NC STATE LICENSES; 4683 LAREDO AVE. 4370 MOTORSPORT DRIVE NC SPRINKLER 29745 FT. MYERS, FL 33905-4924 CONCORD, NC 28027-8977 NC ALARM; 29222 SP LV PHONE: (239) 433-3030 PHONE: (704) 782-3032 SC SPRINKLER: 1116 FAX: (239) 433-3263 FAX: (704) 795-6838 SC ALARM: 3385 00581L (UNDERGROUND) THORNBROOKE TOWNHOMES WHITE CEDAR ROAD SANFORD FL 32771 TAYLOR MORRISON HOMES 151 SOUTHHALL LANE, SUITE 200 MAITLAND, FL 32751 SHEET TITLE- FIRE PROTECTION SITE NOTES & DETAILS PLAN DRAWN BY, MICKEY FERGUSON TOTAL A/S, (SEE FLOOR PLANS) DATE, APRIL 6, 2017 AHI) CITY OF SANFORD CDNTRACT # 86022 CENTER OF TILE JOB? YES N❑ CENTER ON FIXTURES JOB?[:JYES NO SHEET I FOCCUPANCY, CONSTRUCTION TYPE, I NOTE 1: THESE CURE TIMES ARE FOR NEW CONSTRUCTION. IF GLUING INTO EXISTING P1IMILIr- C•111+17 At- LAI TLIC 1^AQI= PIG' P•1 PT_IAI@ PI IE30 TILAO CLIMI 11 n QC A LAIKHLA ILL CURE 200 PSI TIMES WITH ONE (MAXIMUM) TEST STEP SOLVENT CEMENT PRESSURE (SEE NOTE 1) PIPE SIZE INCHES PIPE SIZE INCHES AMBIENT TEMPERATURE DURING CURE PERIOD 60°F TO 120°F 40'F TO 59°F 0°F. TO 39°F 3/4' 45 MIN, 1,5 HR. 1,5 HR. 24 HR, 1' 45 MIN, 10 DAYS 1,5 HR, 24 HR, 1Y4' 1,5 HR, 8 HR. 16 HR, 120 HR. ly2' L5 HR. SEE NOTE 2 16 HR, 120 HR. 2" 6 HR, 44,6' 36 HR. SEE NOTE 2 2y' 8 HR, 8.5' 17,3' 72 HR. SEE NOTE 2 3' 8 HR, 0,6' 72 HR. SEE NOTE 2 NOTE 1: THESE CURE TIMES ARE FOR NEW CONSTRUCTION. IF GLUING INTO EXISTING P1IMILIr- C•111+17 At- LAI TLIC 1^AQI= PIG' P•1 PT_IAI@ PI IE30 TILAO CLIMI 11 n QC A LAIKHLA ILL CURE TIMES WITH ONE 225 PSI (MAXIMUM) TEST STEP SOLVENT CEMENT PRESSURE (SEE NOTE 1) (73°F) PIPE SIZE INCHES AMBIENT TEMPERATURE DURING CURE PERIOD 60°F TO 120°F 4WF TO 59°F 0°F TO 39°F 3/' 1 HR, 4 HR, 48 HR. 1' 1,5 HR. 4 HR. 48 HR, lY4' 3 HR. 32 HR, 10 DAYS ly2' 3 HR, 32 HR. 10 DAYS 2' 8 HR. 48 HR, SEE NOTE 2 2y' 24 HR, 96 HR, SEE NOTE 2 3' 24 HR, 96 HR, SEE NOTE 2 NOTE 1: THESE CURE TIMES ARE FOR NEW CONSTRUCTION. IF GLUING INTO EXISTING P1IMILIr- C•111+17 At- LAI TLIC 1^AQI= PIG' P•1 PT_IAI@ PI IE30 TILAO CLIMI 11 n QC A LAIKHLA ILL ALL MATERIAL APPLICABLE TO THIS PROJECT WILL R MAX ANY DISTANCE S AX ---- HANGER BE INDICATED WITH A (Q� ) (1/2 'S' MAX) OR CLAMP (TYP,) ALL PLASTIC PIPE 3/4" THROUGH 2Y2" SHALL 13E UL LISTED OR .FM APPROVED CPVC MANUFACTURED IN ACCORDANCE WITH ASTM F-442. ALL PLASTIC FITTINGS SHALL BE UL LISTED OR FM APPROVED CPVC MANUFACTURED IN ACCORDANCE WITH ASTM F438, ASTM F439 OR ASTM F1970. ALL CPVC PIPE AND FITTINGS SHALL BE ASSEMBLED USING 'ONE STEP' 500 CEMENT,UNHEATED ;� OR CPVC PIPE SHALL BE ALLOWED TO BE USED IN ORDINARY HAZARD ROOMS OF 400 SQUARE FEET OR INSULATION ATTIC LESS OF OTHERWISE LIGHT HAZARD OCCUPANCIES (NFPA 13 SECTION 6.3.6.2 OR NFPA 1311 SECTION (BY OTHERS) SPRINKLER TEE DROP SUPPORT SPACING WITH SPRINKLER DROP SUPPORT SPACING 5.2.2.3)' I ONE RESTRAINT POINT - SEE TABLE 1 BELOW WITH TWO RESTRAINT POINTS - ALL 1' TO 2" THREADED BLACK STEEL PIPE SHALL BE UL LISTED/FM APPROVED AND MANUFACTURED CEILING SEE TABLE 2 BELOW IN ACCORDANCE WITH ASTM A-135 OR A-795, ACCEPTABLE PIPE BRANDS ARE WHEATLAND 19`-8" -~� R MAX 'MEGATHREAD', ALLIED 'DYNATHREAD', BULL MOOSE TUBE 'EODYTHREAD' AND WELDED TUBE -BERKELEY 'STEADY -THREAD'. ALL PIPE SHALL BE CPVC COMPATIBLE. (� HEATED HEATED L FEET I I, L MAX I UNIT /1' UNIT ALL 1" TO 2" THREADED GALVANIZED PIPE WILL BE SCHEDULE 40 HOT DIPPED GALVANIZED MANUFACTURED IN ACCORDANCE WITH ASTM A-795 OR ASTM A-53. D ALL 1" TO 2' THREADED BLACK STEEL PIPE SHALL BE SCHEDULE 40 UL LISTED/FM APPROVED AND L2 _ MANUFACTURED IN ACCORDANCE WITH ASTM A-795. ACCEPTABLE PIPE MANUFACTURERS ARE d - 0 329 - d INCHES WHEATLAND, ALLIED, BULL MOOSE TUBE AND WELDED TUBE -BERKELEY. ALL PIPE SHALL BE CPVC D _ ` COMPATIBLE. F] ALL lY4" TO 4" GROOVED BLACK STEEL PIPE SHALL BE UL LISTED/FM APPROVED AND MANUFACTURED ~� SPRINKLER 90° ELL DROP SUPPORT SPACING WITH MAXIMUM SUPPORT SPACING IN ACCORDANCE WITH ASTM A795. ACCEPTABLE BRANDS ARE BULL MOOSE'EUDYFLOW', WHEATLAND ONE RESTRAINT POINT - SEE TABLE 1 BELOW SEE TABLE 3 BELOW MEGA -FLOW', ALLIED 'DYNA-FLOW' AND WELDED TUBE -BERKELEY 'STEADY -FLOW'. ALL PIPE SHALL BE CPVC COMPATIBLE PERMISSIBLE BENDING DEFLECTIONS SDR 13,5 (ONE END RESTRAINED) (73°F) 3/ INCH 0'-9' PIPE SIZE INCHES 1 INCH 1'-0" LENGTH OF RUN (L) IN FEET F-0' IYR INCH 2' 5' 7' 10' 12' 15' 17' 20' Y4' 113' 7,8' 15,4' 31,3" 45.1' 70,5' 90,6' 125,4' 1' 1,0' 63' 12.3" 25.0' 36.0' 56,3' 72.3' 100.1' 1V 018' 5,0' 93' 19,8' 28,5' 44,6' 57,3' 79,3' 1ST" 0,7' 4,3' 8.5' 17,3' 24,9' 39,0' 50,1' 693' 2' 0,6' 15' 6,8' 13,9' &0, 31.2' 40,0' 55,4' 0.1' 0,5' 2,9' 5,6" HAN 16.5' 25,8' 33.1' 45,8' 3' 0,4" 2.4' 4,6' 9,4' 13.5' 21.2' 27,2' 37,6' ALL MATERIAL APPLICABLE TO THIS PROJECT WILL R MAX ANY DISTANCE S AX ---- HANGER BE INDICATED WITH A (Q� ) (1/2 'S' MAX) OR CLAMP (TYP,) ALL PLASTIC PIPE 3/4" THROUGH 2Y2" SHALL 13E UL LISTED OR .FM APPROVED CPVC MANUFACTURED IN ACCORDANCE WITH ASTM F-442. ALL PLASTIC FITTINGS SHALL BE UL LISTED OR FM APPROVED CPVC MANUFACTURED IN ACCORDANCE WITH ASTM F438, ASTM F439 OR ASTM F1970. ALL CPVC PIPE AND FITTINGS SHALL BE ASSEMBLED USING 'ONE STEP' 500 CEMENT,UNHEATED ;� OR CPVC PIPE SHALL BE ALLOWED TO BE USED IN ORDINARY HAZARD ROOMS OF 400 SQUARE FEET OR INSULATION ATTIC LESS OF OTHERWISE LIGHT HAZARD OCCUPANCIES (NFPA 13 SECTION 6.3.6.2 OR NFPA 1311 SECTION (BY OTHERS) SPRINKLER TEE DROP SUPPORT SPACING WITH SPRINKLER DROP SUPPORT SPACING 5.2.2.3)' I ONE RESTRAINT POINT - SEE TABLE 1 BELOW WITH TWO RESTRAINT POINTS - ALL 1' TO 2" THREADED BLACK STEEL PIPE SHALL BE UL LISTED/FM APPROVED AND MANUFACTURED CEILING SEE TABLE 2 BELOW IN ACCORDANCE WITH ASTM A-135 OR A-795, ACCEPTABLE PIPE BRANDS ARE WHEATLAND 19`-8" -~� R MAX 'MEGATHREAD', ALLIED 'DYNATHREAD', BULL MOOSE TUBE 'EODYTHREAD' AND WELDED TUBE -BERKELEY 'STEADY -THREAD'. ALL PIPE SHALL BE CPVC COMPATIBLE. (� HEATED HEATED L FEET I I, L MAX I UNIT /1' UNIT ALL 1" TO 2" THREADED GALVANIZED PIPE WILL BE SCHEDULE 40 HOT DIPPED GALVANIZED MANUFACTURED IN ACCORDANCE WITH ASTM A-795 OR ASTM A-53. D ALL 1" TO 2' THREADED BLACK STEEL PIPE SHALL BE SCHEDULE 40 UL LISTED/FM APPROVED AND L2 _ MANUFACTURED IN ACCORDANCE WITH ASTM A-795. ACCEPTABLE PIPE MANUFACTURERS ARE d - 0 329 - d INCHES WHEATLAND, ALLIED, BULL MOOSE TUBE AND WELDED TUBE -BERKELEY. ALL PIPE SHALL BE CPVC D _ ` COMPATIBLE. F] ALL lY4" TO 4" GROOVED BLACK STEEL PIPE SHALL BE UL LISTED/FM APPROVED AND MANUFACTURED ~� SPRINKLER 90° ELL DROP SUPPORT SPACING WITH MAXIMUM SUPPORT SPACING IN ACCORDANCE WITH ASTM A795. ACCEPTABLE BRANDS ARE BULL MOOSE'EUDYFLOW', WHEATLAND ONE RESTRAINT POINT - SEE TABLE 1 BELOW SEE TABLE 3 BELOW MEGA -FLOW', ALLIED 'DYNA-FLOW' AND WELDED TUBE -BERKELEY 'STEADY -FLOW'. ALL PIPE SHALL BE CPVC COMPATIBLE TABLE 1 - SPRINKLER SUPPORT SPACING DISTANCE WITH ONE RESTRAINT POINT PERMISSIBLE BENDING DEFLECTIONS SDR 13,5 (BOTH ENDS RESTRAINED) (73°F) 3/ INCH 0'-9' PIPE SIZE INCHES 1 INCH 1'-0" LENGTH OF RUN (L) IN FEET F-0' IYR INCH 2' 5' 7' 10' 12' 15' 17' 20' 3q' 0.3' 2.0" 3.8' 7,8' 10' 17,6' 22,6' 31,3' I' 0.3' 1,6' 3.1' 63" 9,0' 14,1' 1811' 25.0' IV 012" 1.2' 2,4' 5,0' TV 11,2' 14,3' 19,8" 1' x 0,2' 1,1' 21' 4,3" 6.2' 9,7` 12,5' 17,3' 2' 0,1' 0,9' 1,7' 3,5' 5,0' 7,8' 1010' 13,9' 2i 1 0.1' OJ' 1.4' 2,9' 4.1' 6,4" 8,3' 11,4' 3' 0.1' 0,6' 1.2' 2,4' 3.4' 5,3' 6,8' STAN TABLE 1 - SPRINKLER SUPPORT SPACING DISTANCE WITH ONE RESTRAINT POINT NOM. PIPE SIZE 'R' @ LESS THAN 100 PSI 'R' @ GREATER THAN 100 PSI 3/ INCH 0'-9' 0'-6' 1 INCH 1'-0" 0'-9' ly INCH 1'-4' F-0' IYR INCH 2'-0' 1'-0' > Y2 INCH 21--0' 1'-0" TABLE 2 - SPRINKLER SUPPORT SPACING DISTANCE WITH TWO RESTRAINT POINTS NOM, PIPE SIZE 3/4 INCH 'S' @ LESS THAN 100 PSI 4'-0' 'S' @ GREATER THAN 100 PSI 3'-0' 1 INCH 5'-0' 4'-0' 1Y4 INCH 6'-0' T-0' IY INCH 7'-0' 7'-0' MY INCH 7'-0' 7'-0' {� 211D FLOOR ALL 1Y4" TO 4" GROOVED BLACK STEEL PIPE SHALL BE SCHEDULE 10, UL LISTED/FM APPROVED AND MANUFACTURED IN ACCORDANCE WITH ASTM A-795. ACCEPTABLE MANUFACTURERS ARE BULL MOOSE, WHEATLAND, ALLIED AND WELDED TUBE -BERKELEY. ALL PIPE SHALL BE CPVC COMPATIBLE. CEILING ALL GROOVED STEEL PIPE 6" AND LARGER SHALL BE UL LISTED/FM APPROVED SCHEDULE 10 AND 9'- 4 MANUFACTURED IN ACCORDANCE WITH ASTM A-135. ALL GROOVED STEEL PIPE l/4' AND LARGER 'SHALL BE SCHEDULE 10 HOT DIPPED GALVANIZED AND HEATED HEATED MANUFACTURED IN ACCORDANCE WITH ASTM A-795. UNIT UNIT ALL STEEL PIPE SHALL HAVE A CORROSION RESISTANCE RATIO (CRR) OF NOT LESS THAN 1.0 PER WAFS STANDARDS. ALL BLACK THREADED FITTINGS SHALL BE DUCTILE IRON CLASS 150 OR CLASS 300 ANSI B16,3, CAST IRON CLASS 125 OR CLASS 250 ANSI B16.4 OR MALLEABLE IRON CLASS 150 OR CLASS 300 ANSI B16.3. L__] ALL UALVANILtU IHHtAUEU FITTINGS SHALL BE MALLEABLE IHUN CLASS I5CJ UH CLASS 300 ANSI OF 24 816.3 WITH GALVANIZED COATING IN ACCORDANCE WITH ASTM A-153. - L FEET I TABLE 3 -MAXIMUM SUPPORT SPACING � .1ST FLOOR 0 NOTE 21 FOR THESE SIZES, THE SOLVENT CEMENT CAN BE APPLIED AT TEMPERATURES ALL WELDED OUTLETS SHALL BE UL LISTED OR FM APPROVED AND MANUFACTURED IN ACCORDANCE BELOW 32°F, HOWEVER, THE SPRINKLER SYSTEM TEMPERATURE MUST BE RAISED TO A WITH ANSI 316.11. TEMPERATURE OF 32°F OR ABOVE AND ALLOWED TO CURE PER THE ABOVE ` \ / NOM, PIPE INCH 1 INCH 1Y4 INCH lY INCH 2 INCH 2Y INCH 3 INCH E]SIZE GROOVED FITTINGS SHALL BE UL LISTED OR FM APPROVED AND MANUFACTURED IN ACCORDANCE WITH RECOMMENDATIONS PRIOR TO PRESSURE TESTING, D / ASTM A-536 FOR DUCTILE IRON OR ASTM A-47 FOR MALLEABLE IRON. d = 0,0823 L 2 \\ d INCHES // SUPPORT 1 5'-6' 6'-0' 6'-6' 7'-0' 8'-0' 9'-0' 10'-0' D \ � / / SPACING 'L' � ALL GALVANIZED GROOVED FITTINGS SHALL BE UL LISTED OR FM APPROVED AND MANUFACTURED IN ACCORDANCE WITH ASTM A-536 FOR DUCTILE IRON OR ASTM A-47 FOR MALLEABLE IRON. GALVANIZED COATING SHALL BE IN ACCORDANCE WITH ASTM A-153. - r E] ALL GROOVED STEEL PIPE SHALL BE ROLL GROOVED PER PIPE MANUFACTURER REQUIREMENTS, TYPICAL CPVC CURE TIMES CPVC BENDING DEFLECTIONS TYPICAL CPVC HANGER/BRACE SPACING PIPE AND FITTINGS GENERAL NOTES SCALEI NONE SCALE: NONE SCALE, NONE SGALEI NONE(>'�OA ICAL RESIDENTIAL CROSS SECTION 2 FLOOR �� AY%iE Al(INE Automatic Fire Sprinklarv, Inc. Automatic Fire Sprinklere, Inc. Automatic Fire Sprinklere, Inc. Automeba Fire SprW&ra. kvm E SCALE, NONE Automatic Fire Sprinklere, Inc. 00415N 00416N 00356N 00859N 00683N CEILING #12 X 1Y4' HARDENED CEILING TYPICAL CEILING STRAP MAY BE USED HEX HEAD CPVC SPRINKLER Q� ALTERNATE USAGE IN THIS POSITION AS SELF -THREADING LINE (%' TO 2") q FIG, 24 PIPE HANGER" DIFFUSER A RESTRAINER ONLY SCREW TYP, R1'-0' --- TOLCO FIG, #22C VIEW 'A' TYP, SOFFIT (CONSISTING OF (2} TYPICAL PENDENT TOLCO FIG. 22 PIPE = V-0' (OBSTRUCTION) B STRAPS) 'INTOMIATE' SPRINKLER CPVC SPRINKLER WOOD FRAMINGTYPICAL B TYP LINE (%' TO 2') MEMBER ��' � PENDENT .y%rid SPRINKLER A TYPICAL TElFMTURE %✓ OBSTRUCTION J D-ASSIFI.CATIIlrI VIEW 'A' %'` ALTERNATE USAGE OF FIG. 24 PIPE HANGER D A � �� � SEE DETAIL VIEW DETAILVIEW ­7�) WALL A (D - 8 IR) + B (A > (D - 0,2M) + B) P ®TOLCO FIG, 22 WOOD FRAMING ' �' �' 9-00- PIPE STRAP #10 X V OR TOLCO FIG, 24 D S 30 IN, (0,8M)MEMBER I� � (SIZED TO PIPE) #12 X ly' HARDENED PIPE HANGER CPVC SPRINKLER -' HEX HEAD LINE (Y4' TO 2') WOOD FRAMING SELF -THREADING SCREW HEAD SELF -THREADING NG EX (X2) DISTANCE FROM SPRINKLER 'IO SIDE OF OBSTRUCTION (A) MAXIMUM ALLOWABLE DISTANCE OF DEFLECTOR ABOVE BOTTOM OF OBSTRUCTION (IN,) (B) LESS THAN 1 FT, 6 IN, 0 1 FT. 6 IN TO LESS THAN 3 FT, 1 3 FT, TO LESS THAN 4 FT, 3 4 FT, TO LESS THAN 4 FT, 6 IN, 5 4 FT, 6 IN, TO LESS THAN 6 FT. 7 6 FT, TO LESS THAN 6 FT, 6 IN, 9 6 FT, 6 IN, TO LESS THAN 7 FT, 11 7 FT, AND GREATER 14 '[>RDINARY' »1 l I INtr-�OFt'L'�LN'P O WNEFt IN'E'ORiVLA.�C'ION �� E-iCC� E'LEi�LE'N'L'S NO L TEWERATURE FIRE SPRINKLER CONSTRUCTION DRAWINGS AND SHOP DRAWINGS MAY INCLUDE BACKGROUND DRAWINGS OR GRAPHICS BORROWED FROM THE ARCHITECTURAL, CIVIL, C> FICATHIN 2'-0' -M TYP, SYSTEMS. PER SECTION 4,1, THE RESPONSIBILITY FOR PROPERLY MAINTAINING A NOT ACCEPT ANY RESPONSIBILITY FOR THESE ELEMENTS. THE FIRE SPRINKLER WATER BASED FIRE PROTECTION SYSTEM SHALL BE THAT OF THE OWNER. IF THE ENGINEER IS ONLY RESPONSIBLE FOR THOSE PORTIONS OF THE FIRE SPRINKLER R2'-0' DRAWINGS DEPICTING FIRE SPRINKLER SCOPES OF WORK, REFER 70 APPROVED ARCHITECTURAL, STRUCTURAL, MEP OR CIVIL DRAWINGS FOR AUTHORITATIVE TYP, THE NEAREST OFFICE OF WAYNE AUTOMATIC FIRE SPRINKLERS, INC, TYP, NOTE1 SPRINKLERS MUST BE LOCATED OUTSIDE OF SHADED AREA MEMBER HANGER #04F SCREW (X2) HANGER #04J NFPA 1311 €r 13D RESIDENTIAL PENDENT FOR 3/4" TO 2" CPVC PIPE HANGER #04G FOR 3/4" 70 �" CPVC PIPE FIG. 24 HANGER FOR 3/4" TO �' CPVC PIPE NFPA 1311 Er 13D RESIDENTIAL PENDENT TYPICAL RESIDENTIAL CEILING MOUNTED HOT AIR SPRINKLER CLEARANCE W/ SOFFIT SPRINKLER CLEARANCE W/ OBSTRUCTION DIFFUSER SPRINKLER MINIMUM CLEARANCES E / SCALE, NONE AYIdE SCALD NONE Al(P�E SCALD NONE AYNE SCALE, NONE\"VeARE SCALE, NONE AXNE SCALE, NONE AYiVSK*&k". 00250N 00282N P Automatic Fire Sprinklvrv, Inc. 00531N A"tD1O°SQ F*'° ". k1O' 00251N �01"'S0 H''' �' Autnrrtet�o Fr�. � � Automatic Fire Sprinklers, Inc. 00527N Automatic Fire Sprinklere, Inc. 00702N SPRINKLERS SPACING SYMBOL I MAXIMUM I MINIMUM lCOMMENTS r--QUANTITY---i SPRINKLERS IISYMBI IST 12ND I I I SIN 19ZEI K ITEMPI MODEL TOTAL PER FLOOR TOTAL PER UNIT TOTAL THIS SHEET DATE SUBMIT'I'AIS By INtr-�OFt'L'�LN'P O WNEFt IN'E'ORiVLA.�C'ION �� E-iCC� E'LEi�LE'N'L'S NO L THIS DRAWING IS BASED ON THE OWNER'S ACCEPTANCE OF THE CURRENTLY ADOPTED FIRE SPRINKLER CONSTRUCTION DRAWINGS AND SHOP DRAWINGS MAY INCLUDE BACKGROUND DRAWINGS OR GRAPHICS BORROWED FROM THE ARCHITECTURAL, CIVIL, EDITION (EITHER STATE OR LOCAL) OF NFPA 25 AS THE APPLICABLE STANDARD FOR STRUCTURAL, OR MEP DRAWINGS. THESE REFERENCE BACKGROUND ELEMENTS ARE FOR THE INSPECTION, TESTING AND MAINTENANCE OF WATER BASED FIRE PROTECTION GENERAL INFORMATION OR CONTEXT ONLY AND THE FIRE SPRINKLER ENGINEER DOES SYSTEMS. PER SECTION 4,1, THE RESPONSIBILITY FOR PROPERLY MAINTAINING A NOT ACCEPT ANY RESPONSIBILITY FOR THESE ELEMENTS. THE FIRE SPRINKLER WATER BASED FIRE PROTECTION SYSTEM SHALL BE THAT OF THE OWNER. IF THE ENGINEER IS ONLY RESPONSIBLE FOR THOSE PORTIONS OF THE FIRE SPRINKLER BUILDING OWNER HAS NOT RECEIVED A COPY OF THIS PAMPHLET AND/OR IS NOT DRAWINGS DEPICTING FIRE SPRINKLER SCOPES OF WORK, REFER 70 APPROVED ARCHITECTURAL, STRUCTURAL, MEP OR CIVIL DRAWINGS FOR AUTHORITATIVE FAMILIAR WITH THE OPERATION AND MAINTENANCE OF THIS SYSTEM, PLEASE CONTACT EXPRESSIONS OF BACKGROUND INFORMATION THAT MAY BE UTILIZED IN FIRE THE NEAREST OFFICE OF WAYNE AUTOMATIC FIRE SPRINKLERS, INC, SPRINKLER DRAWINGS OR DETAILS I CENTER ON FIXTURES JOB? 0 YES NO aET I CPVC CC)iMPA'PIBILYPY NO'PICE CPVC FIRE SPRINKLER PIPING SYSTEMS HAVE BEEN USED SUCCESSFULLY FOR MORE III FT. MYERS. FL 4663 LAREDO AVE FT. MYERS, FL 33905-4824 PHONE (239) 433-3030 FAX: (239) 433-3263 THAN 20 YEARS IN NEW CONSTRUCTION, RE -PIPE AND REPAIR. CPVC PRODUCTS ARE SIZE, GPM @ PSI IDEALLY SUITED FOR THESE APPLICATIONS DUE TO THEIR OUTSTANDING CORROSION HAZARD CLASS RESISTANCE, OCCASIONALLY, HOWEVER, CPVC CAN BE DAMAGED BY CONTACT WITH CHEMICALS FOUND IN SOME CONSTRUCTION MATERIALS QEI SOME WIRES, FLUX, STATIC PRESSURE PETROLEUM BASED PRODUCTS, ETC.) AND ANCILLARY PRODUCTS SUCH AS THREAD SEALANTS, LEAK DETECTORS, FIRESTOPS, ETC. ANY PRODUCT THAT COMES IN 2' CONTACT WITH CPVC SPRINKLER PIPE MUST BE EVALUATED IN ACCORDANCE WITH THE SYSTEM COMPATIBILITY PROGRAM AS FOUND AT WWW.SYSTEMCOMPATIBLE.COH - f I CO:P YRIGPI 1, ALL DOCUMENTS, INCLUDING ORIGINAL DRAWINGS, SPECIFICATIONS, FIELD NOTES, DESIGN AREA ESTIMATES AND DATA, INCLUDING COMPUTER PROGRAMS PURSUANT 70 THIS PROJECT ARE AND WILL REMAIN THE PROPERTY OF WAYNE AUTOMATIC FIRE SPRINKLERS, INC. RESIDUAL PREWK (WAFS) AS INSTRUMENTS OF SERVICE. THEY ARE NOT INTENDED, NOR REPRESENTED TO BE SUITABLE FOR RE -USE BY THE CLIENT, OR OTHERS, ON EXTENSION OF THIS 10111!11 PROJECT, OR FOR ANY OTHER PROJECT. ANY REUSE, OR ADAPTATION OF THE NFORMATION CONTAINED HEREIN, WITHOUT SPECIFIC WRITTEN PERMISSION FROM WAFS WILL BE AT THE CLIENTS SOLE RISK, WITHOUT LIABILITY, OR LEGAL EXPOSURE TO 1000 GPM WAFS, AND WILL ENTITLE WAFS TO FURTHER COMPENSATION AT RATES TO BE TIME OF TEST AGREED ON BETWEEN WAFS AND THE CLIENT. THE CLIENT SHALL ALSO INDEMNIFY DESIGN AREA SF, AND HOLD WAFS HARMLESS FROM ANY AND ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES, INCLUDING ATTORNEYS FEES RESULTING FROM ANY SUCH PERMISSIONS. PITOT READING SPRINKLERS SPACING SYMBOL I MAXIMUM I MINIMUM lCOMMENTS r--QUANTITY---i SPRINKLERS IISYMBI IST 12ND I I I SIN 19ZEI K ITEMPI MODEL TOTAL PER FLOOR TOTAL PER UNIT TOTAL THIS SHEET DATE SUBMIT'I'AIS By s WA"E Automatic Fire Sprinklers, Inc. MAIN OFFICE -ORLANDO, FLORIDA 222 CAPITOL COURT OCOEE, FLORIDA 34761 PHONE: (407) 656-3030 FAX: (407) 655-8026 WATER SUPPLY INFORMATION DESIGN CRITERIA DATE- DOM OR FIRE PUMP SYSTEM / DESIGN AREA N CITY OF SANFORD ,i NO. DATE REVISIONS By 1 A A �E ACTUAL EXTRAPOLATED POMPANO BEACH„ FL 3121 NW 16TH TERRACE POMPANO BEACH, FL 33064-1408 PHONE (954) 917-3030 FAX: (954) 917-9424 CENTER OF TILE JOB7 IJ YES WND I CENTER ON FIXTURES JOB? 0 YES NO aET I FPDA CONSTRUCTION TYPE, V-13 III FT. MYERS. FL 4663 LAREDO AVE FT. MYERS, FL 33905-4824 PHONE (239) 433-3030 FAX: (239) 433-3263 (AS REVD BY AHJ) SIZE, GPM @ PSI HAZARD CLASS STATIC PRESSURE 65 PSI HYDRANT ELEV, 2' If OF SPRINKLERS IN DESIGN AREA RESIDUAL PREWK 55 PSI DATE OF TEST 10111!11 MINIMUM DENSITY FLOW IN GPM 1000 GPM TIME OF TEST 8D0 AM DESIGN AREA SF, PITOT READING 36 PSI NUMBER OF PORTS FLOWED 1 PSI RE'D R BV GPM REQ'D @ BV [EST PROVIDED BY 'WAYNE AUTOMATIC FIRE SPRINKLERS, INC, PSI REWD a HYD GPM REQ'D @ HYD ELEVATION @ HIGHEST SPRINKLER HYDRANT LOSE INSIDE/QUTSIDE LOCATION OR TEST HYDRANT LOCATED ON WHITE CEDAR ROAD MAND DOMESTIC DEMAND SPRINKLERS SPACING SYMBOL I MAXIMUM I MINIMUM lCOMMENTS r--QUANTITY---i SPRINKLERS IISYMBI IST 12ND I I I SIN 19ZEI K ITEMPI MODEL TOTAL PER FLOOR TOTAL PER UNIT TOTAL THIS SHEET DATE SUBMIT'I'AIS By s WA"E Automatic Fire Sprinklers, Inc. MAIN OFFICE -ORLANDO, FLORIDA 222 CAPITOL COURT OCOEE, FLORIDA 34761 PHONE: (407) 656-3030 FAX: (407) 655-8026 04/17/17 QA REVIEW MPF DATE- APRIL 6, 2017 A" CITY OF SANFORD ,i NO. DATE REVISIONS By 1 A A �E 71 JACKSONVILLE, FL 11326 CGTRJ13UTION AVE WEST JACKSONVILLE. FL 32256-2745 PHONE (904) 268-3030 FAX: (904) 268-0724 TAMPA, FL 3226 CHERRY PALM DRIVE TAMPA, FL 33619-0337 PHONE (913) 630-0303 FAX: (BT3) 630-0312 POMPANO BEACH„ FL 3121 NW 16TH TERRACE POMPANO BEACH, FL 33064-1408 PHONE (954) 917-3030 FAX: (954) 917-9424 CENTER OF TILE JOB7 IJ YES WND I CENTER ON FIXTURES JOB? 0 YES NO aET I FPDA CONSTRUCTION TYPE, V-13 III FT. MYERS. FL 4663 LAREDO AVE FT. MYERS, FL 33905-4824 PHONE (239) 433-3030 FAX: (239) 433-3263 CONCORD. NC 4370 MOTORSPORT DRIVE D C 8 - CONCO R , N 2 027 8977 PHONE (704) 782-3032 FAX: (704) 795-6638 STATE LICENSES: NC SPRINKLER: 29745 NC ALARM: 29222 SP LV 5C SPRINKLER 1116 SC ALARM: 3365 ti LOTS 257-263 THORNEBROOKE TOWNHOMES WHITE CEDAR ROAD SANFORD FL 32771 TAYLOR MORRISON HOMES 151 SOUTHHALL LANE, SUITE 200 MAITLAND, FL 32751 I, SHEET TITLE FIRE SPRINKLER DETAILS DRAWN BYn MICKEY FERGUSON TOTAL A/9 128 DATE- APRIL 6, 2017 A" CITY OF SANFORD CINTRACT 1 85828 CENTER OF TILE JOB7 IJ YES WND I CENTER ON FIXTURES JOB? 0 YES NO aET I FPDA CONSTRUCTION TYPE, V-13 OCCUPANCY t - 113 2' 8' 1' 0 4' Bedroom #2 8'-0' Mg. Q� t O O 2 5D Bathroom #2 � 5�3.�Ft �i0 IT-- o_ � Bedroom #3 8'-0' Mg, I--=Clos:-- II -aund ii 8 0 II ° vner' ath � To j� s S Ft ,1 Sq�Ft 8'- ' Mg, A S sips. No A S�-AHI —I 7, Scl Ft ° --�L ,y ® W.I.C. , , B2If'Pr ,�,,� 0—i I 4.1 Sq f _A_ 8'� Mc ,� II \.�• rs� I I 8� nen7II ° A/1 i i 21 00 D 7 y, V — f BC I F----- L_ r-1 ` if L'r-J 114 O I� Min, � ! J `LO�2 B3 Owner's Suite / BBT � / rltil / L r_j L -J / / L--- — — — —L—/ 8'-0" Mg, IJ 1 1 IoV VI 1 2ND FLOOR BIRCH UNIT FIRE PROTECTION PLAN Open To Below Sitting DESIGN AREA 118-1 2ND FLOOR UNIT B HALLWAY COMPARTMENT DESIGN PER NFPA 13D, 2010 EDITION, SECTION 812 B1 16' X 16' SPACING 13.0 GPM @ 7,0 PSI B2 16' X 16' SPACING 13.0 GPM @ 7A PSI �"/V�� E AuMe.4' i. rt. WW.. 00853N DESIGN AREA #0-2 2ND FLOOR UNIT B OWNER'S SUITE COMPARTMENT DESIGN PER NFPA 13D, 2010 EDITION, SECTION B.1.E B3 20' X 20' SPACING 20,0 GPM @ 16,7 PSI B4 16' X 16' SPACING �� 13,0 GPM @ 7,0 PSI �AVVA NE 00853N JJ A„twatb Ft. 6.,Ndx.. iw. F TO SPRINKLER SYSTEM SEE UNIT PLANS FOR CONTINUATION 6' 120VAC BELL W/WEATHERPROOF BACK BOX LOCATE ON OUTSIDE WALL OF — WOOD FLUOR TRUSS BUILDING (WIRED BY OTHERS) - -- 1�' SPLIT RING HANGER 3/8' A.T.R. & HILTI DROP-IN ANCHOR Cj W X W X V CPVC REDUCING TEE - NO SPARE SPRINKLERS 3' x 3' x V CPVC REDUCING TEE W/ REQUIRED PER NFPA 13D �' x ! ' CPVC SPIG ADAPTER GALV, PLUG AND 300 PSI WATER GAUGE & 3 -WAY VALVE 1VxIVx1' CPVC REDUCING TEE W/POTTER GLUE IN FLOW SWITCH (WIRED BY OTHERS) -•---- 1' CPVC BALL VALVE I 1�' CPVC CHECK VALVE—-)—_"' U U IV COUP & 11¢ 4" CPVC BUSHING Bx J' CPVC 90° OUT WALL TO �'A' SPIGOT ADAPTER OVERHEAD PERMIT TO & SAWN HEAD START AT 1'—®" A.F.F. TYPICAL SPRINKLER .� 0. DYNAFLOW SLEEVE ---- FROM SUPPLY 1 1/2' PIPE ROTATED FOR CLARITY BY OTHERS CPVC TYPICAL EXPOSED CPVC FIRE SPRINKLER RISER E SCALED NONE Fire Sprinklers, Inc. 36' MINIMUM TYPICAL LIGHT ' SF FIXTURE • DESIGN AND INSTALLATION TO BE IN ACCORDANCE WITH 2010 EDITION OF NFPA 130. • DESIGN AND INSTALLATION TO BE IN ACCORDANCE WITH ALL APPLICABLE LOCAL AND STATE CODES. • ALL PIPE AND FITTINGS USED ON THIS PROJECT TO BE IN ACCORDANCE WITH APPLICABLE CODES AND WAFS STANDARDS, SEE PIPE AND FITTINGS GENERAL NOTES (WAFS DETAIL #00593N). • ALL HANGERS SHALL BE DESIGNED AND INSTALLED IN ACCORDANCE WITH NFPA 130 AND THEIR LISTING. • ALL PENETRATIONS THROUGH RATED BUILDING ASSEMBLIES SHALL BE SEALED WITH FIRE CAULK IN ACCORDANCE WITH DETAILS PROVIDED. WAFS POLICY IS TO USE HILTI FS ONE OR STI LCI. • UNDERGROUND MAINS AND LEAD–INS SHALL BE FLUSHED AND SIGNED TEST CERTIFICATES PROVIDED BEFORE A CONNECTION IS MADE TO THE SPRINKLER SYSTEM. • WHEN SYSTEM IS FED USING PLUMBING SERVICE, PIPING SHALL STILL BE FLUSHED PRIOR TO CONNECTING THE SPRINKLER SYSTEM. • ALL PIPING SHALL BE INSPECTED AND APPROVED BY PROPER AUTHORITIES PRIOR TO COVERING WITH DRYWALL. COPIES OF SIGNED TEST CERTIFICATES ARE TO BE FORWARDED TO THE PROPER RECIPIENTS. • ALL SYSTEMS SHALL BE TESTED AT 200 PSI FOR 2 HOURS PER WAFS STANDARDS. • ALL SOFFITS REQUIRED TO CONCEAL SPRINKLER PIPING ARE BY OTHERS. • ALL WIRING OF DEVICES IF PROVIDED (FLOW SWITCHES, TAMPER SWITCHES, ETC) 15 BY OTHERS. • VALVES SHALL NOT BE REQUIRED TO BE MONITORED PER FLORIDA BUILDING CODE 903.4 (1). • LOCAL WATERFLOW ALARMS SHALL BE PROVIDED ON ALL SPRINKLER SYSTEMS IN HOMES NOT EQUIPPED WITH SMOKE ALARMS OR SMOKE DETECTORS IN ACCORDANCE WITH NFPA 72, NATIONAL FIRE ALARM CODE. • CONNECTION OF SPRINKLER DEVICES TO THE BUILDING ALARM OR MONITORING SYSTEM, IF PROVIDED, IS BY OTHERS. • ALL PAINTING OF PIPE AS REQUIRED IS BY OTHERS. Ik ALL INSULATION REQUIRED FOR FREEZE PROTECTION OF SPRINKLER PIPING IS BY OTHERS. • HEATING OF ROOMS TO MAINTAIN TEMPERATURES OF 40 DEGREES OR GREATER IS BY OTHERS. • SPRINKLERS SHALL NOT BE INSTALLED PRIOR TO THE FITTINGS BEING CEMENTED IN PLACE. • ALL SPRINKLERS IN DWELLING UNITS SHALL BE UL LISTED OR FM APPROVED RESIDENTIAL SPRINKLERS. • SPARE SPRINKLERS WILL NOT BE PROVIDED AS THEY ARE NOT REQUIRED BY NFPA 130. • REFER TO SPACING NOTES ON PLANS FOR MAXIMUM CALCULATED SPACING ALLOWANCES. • SPRINKLERS SHALL BE INSTALLED IN ALL AREAS EXCEPT AS FOLLOWS: o BATHROOMS WHERE THE AREA DOES NOT EXCEED 55 SQ FT. o CLOTHES CLOSETS, LINEN CLOSETS AND PANTRIES WITHIN THE DWELLING UNITS THAT OO NOT EXCEED 24 SQUARE FEET, THE LEAST DIMENSION DOES NOT EXCEED 3 FEET, AND THE WALLS AND CEILINGS ARE SURFACED WITH NONCOMBUSTIBLE OR LIMITED–COMBUSTIBLE MATERIALS AS DEFINED BY NFPA 220, STANDARD ON TYPES OF BUILDING CONSTRUCTION. o ANY GARAGES, OPEN ATTACHED PORCHES, CARPORTS AND SIMILAR STRUCTURES. o ATTICS, PENTHOUSE EQUIPMENT ROOMS, ELEVATOR MACHINE ROOMS, CONCEALED SPACES DEDICATED EXCLUSIVELY TO AND CONTAINING ONLY DWELLING UNIT VENTILAION EQUIPMENT, FLOOR/CEILING SPACES, ELEVATOR SHAFTS, CRAWL SPACES, AND OTHER CONCEALED SPACES THAT ARE NOT USED OR INTENDED FOR LIVING PURPOSES AND DO NOT CONTAIN FUEL–FIRED EQUIPMENT. o COVERED UNHEATED PROJECTIONS OF THE BUILDING AT ENTRANCES/EXITS AS LONG AS THERE IS ANOTHER MEANS OF EGRESS FROM THE DWELLING UNIT. o SPRINKLERS SHALL NOT BE REQUIRED FOR CEILING POCKETS THAT MEET THE FOLLOWING CONDITIONS: 1. THE TOTAL VOLUME OF UNPROTECTED CEILING POCKET DOES NOT EXCEED 100 CU. FT. 2. THE ENTIRE FLOOR UNDER THE UNPROTECTED CEILING POCKET IS PROTECTED BY THE SPRINKLERS AT THE LOWER CEILING ELEVATION. 3. EACH UNPROTECTED CEILING POCKET 15 SEPARATED FROM ANY ADJACENT UNPROTECTED CEILING POCKET BY A MINIMUM OF 10 FT. HORIZONTAL DISTANCE. 4. THE INTERIOR FINISH OF THE UNPROTECTED CEILING POCKET IS NONCOMBUSTIBLE OR LIMITED–COMBUSTIBLE MATERIAL. 5. SKYLIGHTS NOT EXCEEDING 32 SQ. FT. SHALL BE PERMITTED TO HAVE A PLASTIC COVER. • WAFS TO PROVIDE ALL REQUIRED SIGNAGE PER NFPA 130 INCLUDING . BUT NOT LIMITED TO VALVES, HYDRAULIC PLACARDS, AND INSPECTION TAGS AS REQUIRED BY FS 633. • DEVICES THAT RESTRICT THE FLOW OR DECREASE THE PRESSURE OR AUTOMATICALLY SHUT OFF THE WATER TO THE SPRINKLER SYSTEM, SUCH AS WATER SOFTENERS, FILTRATION SYSTEMS, AND AUTOMATIC SHUTOFF VALVES, SHALL NOT BE ADDED TO THIS SYSTEM WITHOUT A REVIEW OF THE FIRE SPRINKLER SYSTEM BY A FIRE PROTECTION SPECIALIST. WARE F(rn sp *"", kw. *IN ROOMS/COMPARTMENTS 400 CU, FT, OR LESS, (ANY MODEL IS ACCEPTABLE SPRINKLERS MAY BE PLACED REGARDLESS OF PROVIDED PLAN VIEW OF LOCATION OF OBSTRUCTIONS. BLADES IS 50% OPEN) NFPA 13R D 13D NFPA 13R Er 13D SPRINKLER CLEARANCE W/ LIGHT FIXTURE SPRINKLER CLEARANCE W/ CEILING FAN SCALE, NONE E SCALE, NONE Automatic Fire Sprinklere. Inc. 00504N Automatic Fire Sprinldere, Inc. 00505N SCALE 1/4' = V (11832 SQ. FT.) ,-QUANTITY--, SPRINKLERS INIPOFt l'AN o ar �' �z 1Iv F o zNl �� r'.Eo (� GR�Pj ISO 1 EtijSAW ��TE WATER SUPPLY INFORMATION MAXIMUM DESIGN CRITERIA COMMENTS FIRE SPRINKLER CONSTRUCTION DRAWINGS AND SHOOPP DRAWINGS MAY INCLUDE THIS DRAW ING IS BASED ON THE OWNER'S ACCEPTANCE OF THE CURRENTLY ADOPTED BACKGROUND DRAWINGS OR GRAPHICS BORROWED FROM THE ARCH1'fECTURAL. Clvi! SYSTEM /DESIGN B-1 B'2 SIN SIZE EDITION (EITHER STATE OR LOCAL) OF NFPA 25 AS 'THE APPLICABLE STANDARD FOR STRUCTURAL, OR MEP CRAWINGS. THESE REFERENCE BACKGROUND ELEMENTS ARE FOR FIRE PUMP ERIWT OR I TEMP THE INSPECTION, TESTING AND MAINTENANCE OF WATER BASED FIRE PROTECTION GENERAL 1NFURMATIUN OR CONTEXT ONLY AND THE FIRE SPRINKLER ENGINEER DOES SYSTEMS. PER SECTION 41, THE RESPONSIBILITY FOR PROPERLY MAINTAINING A NOT ACCEPT ANY RESPONSIBILITY FOR THESE ELEMENTS. THE FIRE SPRINKLER EXTRAPOLATED ACTUAL AREA # 16X16 8 BETWEEN 8'-0' MAX SPACING OFF WALL UAO, FPB. 8 12 - R3 R3516WHITE WATER BASED FIRE PROTECTION SYSTE14 SHALL DE THAT OF THE OWNER, 1F THE ENGINEER IS ONLY RESPONSIBLE FOR THOSE PORTIONS OF THE FIRE SPRINKLER (AS REVD BY AHJ) SIZE: GPM @ PSI DRAWINGS DEPICTING FIRE SPRINKLER SCOPES OF WORK. REFER TO APPROVED HAZARD CLASS NFPA 13D NFPA 13D ® - BUILDING OWNER HAS NOT RECEIVED A COPY OF THIS PAMPHLET AND/OR IS NOT - FAMILIAR WITH THE OPERATION AND MAINTENANCE OF THIS SYSTEM, PLEASE CONTACT ARCHITECTURAL, STRUCTURAL, MEP OR CIVIL DRAWINGS FOR AUTHORITATIVE EXPRESSIONS OF BACKGROUND INFORMATION THAT MAY BE UTILIZED IN FIRE STATIC PRESSI.RE 65 PSI HYDRANT ELEV, 2' OF SPRINKLERS IN 2 2 1 THE NEAREST OFFICE OF WAYNE AUTOMATIC FIRE SPRINKLERS, INC, SPRINKLER DRAWINGS OR DETAILS DESIGN AREA T�'4�.9 175' RELIABLI MINIMUMDENSITY,05 .05 1"-4" BELOW COLING RESIDUrk PRESSUR 55 PSI DATE OF TEST 10/11/17 CPVC C0_iMPATI.E3IL11'Y NOTICE WHITE w CPVC FIRE SPRINKLER PIPING SYSTEMS HAVE BEEN USED SUCCESSFULLY FOR MORE FLOW 91 GPM 1000 GPM TIME OF TEST 8:00 AM DESIGN AREA S.F. 2 SPRKS 2 SPRKS THAN 20 YEARS IN NEW CONSTRUCTION, RE -PIPE AND REPAIR, CPVC. PRODUCTS ARE PSI REQ'D @ BB 26,6 43,3 IDEALLY SUITED FOR THESE APPLICATIONS DUE TO THEIR OUTSTANDING CORROSION RESISTANCE, OCCASIONALLY, HOWEVER, CPVC CAN BE DAMAGED BY CONTACT WITH Pilo] READUC 1 36 PSI NUMBER OF PORTS FLOWED 1 CHEMICALS FOLND IN SOME CONSTRUCTION MATERIALS (1E, SOME WIRES, FLUX, PETROLEUM BASED PRODUCTS, ETC,) AND ANCILLARY PRODUCTS SUCH AS THREAD SEALANTS, LEAK DETECTORS, FIRESTOPS, ETC, ANY PRODUCT THAT COMES IN GPM REQ'D @ $B 26,1 40,9 — CONTACT WITH CPVC SPRINKLER PIPE MUST BE EVALUATED IN ACCORDANCE WITH THE SYSTEM COMPATIBILITY PROGRAM AS FOUND AT WWW.SYSTEMCOMPATIBLE.COM _— -, ,EST MVTDED BY WAYNE AUTOMATIC FIRE SPRINKLERS, INC, PSI REQ'D @ HYD 36.7 57,5 GPM REQ'D @ HYD 31,3 45,9 z Q CUP•y-P%IG-FIT ALL DOCUMENTS, INCLUDING ORIGINAL DRAWINGS, SPECIFICATIONS, FIELD NOTES, ELEVATION @ HIGHEST 1pr_pV 191-81 OO 1pr_pi JJ vv U CD ESTIMATES AND DATA, INCLUDING COMPUTER PROGRAMS PURSUANT TO THIS PROJECT ARE AND WILL REMAIN THE PROPERTY OF WAYNE AUTOMATIC FIRE SPRINKLERS, INC. SPRINKLER N (WAFS) AS INSTRUMENTS OF SERVICE, THEY ARE NOT INTENDED, NOR REPRESENTED HOSE N/A N/A fO BE SUITABLE FOR RE -USE BY THE CLIENT, OR OTHERS, UN! EXTENSION OF THIS HYDRANT rl ' r -I PROJECT, OR FOR ANY OTHER PROJECT, ANY REUSE, OR ADAPTATION OF THE INFORMATION CONTAINED HEREIN, WITHOUT SPECIFIC WRITTEN PERMISSION FROM WAFS LOCATION Bit TEST HYDRANT LOCATED ON WHITE CEDAR ROAD INSIDE/OUTSIDE A EXPOSURE TO WILL BE AT THE CLIENTS SOLE RISK, WIiHGUT LIABILITY, OR LEGAL E WAFS, AND WILL ENTITLE WAFS TO FURTHER COMPENSATION AT RATES TC HE NUMBER DOMESTIC DEMAND 5 GPM 5 GPM p AGREED ON BETWEEN WAFS AND 'THE CLIENT, THE CLIENT SHALL ALSO INDEMNIFY cV AND HOLD WAFS HARMLESS FROM ANY AND ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES, INCLUDING ATTORNEYS FEES RESULTING FROM ANY SUCH PERMISSIONS. m i-1 DESIGN AREA 118-1 2ND FLOOR UNIT B HALLWAY COMPARTMENT DESIGN PER NFPA 13D, 2010 EDITION, SECTION 812 B1 16' X 16' SPACING 13.0 GPM @ 7,0 PSI B2 16' X 16' SPACING 13.0 GPM @ 7A PSI �"/V�� E AuMe.4' i. rt. WW.. 00853N DESIGN AREA #0-2 2ND FLOOR UNIT B OWNER'S SUITE COMPARTMENT DESIGN PER NFPA 13D, 2010 EDITION, SECTION B.1.E B3 20' X 20' SPACING 20,0 GPM @ 16,7 PSI B4 16' X 16' SPACING �� 13,0 GPM @ 7,0 PSI �AVVA NE 00853N JJ A„twatb Ft. 6.,Ndx.. iw. F TO SPRINKLER SYSTEM SEE UNIT PLANS FOR CONTINUATION 6' 120VAC BELL W/WEATHERPROOF BACK BOX LOCATE ON OUTSIDE WALL OF — WOOD FLUOR TRUSS BUILDING (WIRED BY OTHERS) - -- 1�' SPLIT RING HANGER 3/8' A.T.R. & HILTI DROP-IN ANCHOR Cj W X W X V CPVC REDUCING TEE - NO SPARE SPRINKLERS 3' x 3' x V CPVC REDUCING TEE W/ REQUIRED PER NFPA 13D �' x ! ' CPVC SPIG ADAPTER GALV, PLUG AND 300 PSI WATER GAUGE & 3 -WAY VALVE 1VxIVx1' CPVC REDUCING TEE W/POTTER GLUE IN FLOW SWITCH (WIRED BY OTHERS) -•---- 1' CPVC BALL VALVE I 1�' CPVC CHECK VALVE—-)—_"' U U IV COUP & 11¢ 4" CPVC BUSHING Bx J' CPVC 90° OUT WALL TO �'A' SPIGOT ADAPTER OVERHEAD PERMIT TO & SAWN HEAD START AT 1'—®" A.F.F. TYPICAL SPRINKLER .� 0. DYNAFLOW SLEEVE ---- FROM SUPPLY 1 1/2' PIPE ROTATED FOR CLARITY BY OTHERS CPVC TYPICAL EXPOSED CPVC FIRE SPRINKLER RISER E SCALED NONE Fire Sprinklers, Inc. 36' MINIMUM TYPICAL LIGHT ' SF FIXTURE • DESIGN AND INSTALLATION TO BE IN ACCORDANCE WITH 2010 EDITION OF NFPA 130. • DESIGN AND INSTALLATION TO BE IN ACCORDANCE WITH ALL APPLICABLE LOCAL AND STATE CODES. • ALL PIPE AND FITTINGS USED ON THIS PROJECT TO BE IN ACCORDANCE WITH APPLICABLE CODES AND WAFS STANDARDS, SEE PIPE AND FITTINGS GENERAL NOTES (WAFS DETAIL #00593N). • ALL HANGERS SHALL BE DESIGNED AND INSTALLED IN ACCORDANCE WITH NFPA 130 AND THEIR LISTING. • ALL PENETRATIONS THROUGH RATED BUILDING ASSEMBLIES SHALL BE SEALED WITH FIRE CAULK IN ACCORDANCE WITH DETAILS PROVIDED. WAFS POLICY IS TO USE HILTI FS ONE OR STI LCI. • UNDERGROUND MAINS AND LEAD–INS SHALL BE FLUSHED AND SIGNED TEST CERTIFICATES PROVIDED BEFORE A CONNECTION IS MADE TO THE SPRINKLER SYSTEM. • WHEN SYSTEM IS FED USING PLUMBING SERVICE, PIPING SHALL STILL BE FLUSHED PRIOR TO CONNECTING THE SPRINKLER SYSTEM. • ALL PIPING SHALL BE INSPECTED AND APPROVED BY PROPER AUTHORITIES PRIOR TO COVERING WITH DRYWALL. COPIES OF SIGNED TEST CERTIFICATES ARE TO BE FORWARDED TO THE PROPER RECIPIENTS. • ALL SYSTEMS SHALL BE TESTED AT 200 PSI FOR 2 HOURS PER WAFS STANDARDS. • ALL SOFFITS REQUIRED TO CONCEAL SPRINKLER PIPING ARE BY OTHERS. • ALL WIRING OF DEVICES IF PROVIDED (FLOW SWITCHES, TAMPER SWITCHES, ETC) 15 BY OTHERS. • VALVES SHALL NOT BE REQUIRED TO BE MONITORED PER FLORIDA BUILDING CODE 903.4 (1). • LOCAL WATERFLOW ALARMS SHALL BE PROVIDED ON ALL SPRINKLER SYSTEMS IN HOMES NOT EQUIPPED WITH SMOKE ALARMS OR SMOKE DETECTORS IN ACCORDANCE WITH NFPA 72, NATIONAL FIRE ALARM CODE. • CONNECTION OF SPRINKLER DEVICES TO THE BUILDING ALARM OR MONITORING SYSTEM, IF PROVIDED, IS BY OTHERS. • ALL PAINTING OF PIPE AS REQUIRED IS BY OTHERS. Ik ALL INSULATION REQUIRED FOR FREEZE PROTECTION OF SPRINKLER PIPING IS BY OTHERS. • HEATING OF ROOMS TO MAINTAIN TEMPERATURES OF 40 DEGREES OR GREATER IS BY OTHERS. • SPRINKLERS SHALL NOT BE INSTALLED PRIOR TO THE FITTINGS BEING CEMENTED IN PLACE. • ALL SPRINKLERS IN DWELLING UNITS SHALL BE UL LISTED OR FM APPROVED RESIDENTIAL SPRINKLERS. • SPARE SPRINKLERS WILL NOT BE PROVIDED AS THEY ARE NOT REQUIRED BY NFPA 130. • REFER TO SPACING NOTES ON PLANS FOR MAXIMUM CALCULATED SPACING ALLOWANCES. • SPRINKLERS SHALL BE INSTALLED IN ALL AREAS EXCEPT AS FOLLOWS: o BATHROOMS WHERE THE AREA DOES NOT EXCEED 55 SQ FT. o CLOTHES CLOSETS, LINEN CLOSETS AND PANTRIES WITHIN THE DWELLING UNITS THAT OO NOT EXCEED 24 SQUARE FEET, THE LEAST DIMENSION DOES NOT EXCEED 3 FEET, AND THE WALLS AND CEILINGS ARE SURFACED WITH NONCOMBUSTIBLE OR LIMITED–COMBUSTIBLE MATERIALS AS DEFINED BY NFPA 220, STANDARD ON TYPES OF BUILDING CONSTRUCTION. o ANY GARAGES, OPEN ATTACHED PORCHES, CARPORTS AND SIMILAR STRUCTURES. o ATTICS, PENTHOUSE EQUIPMENT ROOMS, ELEVATOR MACHINE ROOMS, CONCEALED SPACES DEDICATED EXCLUSIVELY TO AND CONTAINING ONLY DWELLING UNIT VENTILAION EQUIPMENT, FLOOR/CEILING SPACES, ELEVATOR SHAFTS, CRAWL SPACES, AND OTHER CONCEALED SPACES THAT ARE NOT USED OR INTENDED FOR LIVING PURPOSES AND DO NOT CONTAIN FUEL–FIRED EQUIPMENT. o COVERED UNHEATED PROJECTIONS OF THE BUILDING AT ENTRANCES/EXITS AS LONG AS THERE IS ANOTHER MEANS OF EGRESS FROM THE DWELLING UNIT. o SPRINKLERS SHALL NOT BE REQUIRED FOR CEILING POCKETS THAT MEET THE FOLLOWING CONDITIONS: 1. THE TOTAL VOLUME OF UNPROTECTED CEILING POCKET DOES NOT EXCEED 100 CU. FT. 2. THE ENTIRE FLOOR UNDER THE UNPROTECTED CEILING POCKET IS PROTECTED BY THE SPRINKLERS AT THE LOWER CEILING ELEVATION. 3. EACH UNPROTECTED CEILING POCKET 15 SEPARATED FROM ANY ADJACENT UNPROTECTED CEILING POCKET BY A MINIMUM OF 10 FT. HORIZONTAL DISTANCE. 4. THE INTERIOR FINISH OF THE UNPROTECTED CEILING POCKET IS NONCOMBUSTIBLE OR LIMITED–COMBUSTIBLE MATERIAL. 5. SKYLIGHTS NOT EXCEEDING 32 SQ. FT. SHALL BE PERMITTED TO HAVE A PLASTIC COVER. • WAFS TO PROVIDE ALL REQUIRED SIGNAGE PER NFPA 130 INCLUDING . BUT NOT LIMITED TO VALVES, HYDRAULIC PLACARDS, AND INSPECTION TAGS AS REQUIRED BY FS 633. • DEVICES THAT RESTRICT THE FLOW OR DECREASE THE PRESSURE OR AUTOMATICALLY SHUT OFF THE WATER TO THE SPRINKLER SYSTEM, SUCH AS WATER SOFTENERS, FILTRATION SYSTEMS, AND AUTOMATIC SHUTOFF VALVES, SHALL NOT BE ADDED TO THIS SYSTEM WITHOUT A REVIEW OF THE FIRE SPRINKLER SYSTEM BY A FIRE PROTECTION SPECIALIST. WARE F(rn sp *"", kw. *IN ROOMS/COMPARTMENTS 400 CU, FT, OR LESS, (ANY MODEL IS ACCEPTABLE SPRINKLERS MAY BE PLACED REGARDLESS OF PROVIDED PLAN VIEW OF LOCATION OF OBSTRUCTIONS. BLADES IS 50% OPEN) NFPA 13R D 13D NFPA 13R Er 13D SPRINKLER CLEARANCE W/ LIGHT FIXTURE SPRINKLER CLEARANCE W/ CEILING FAN SCALE, NONE E SCALE, NONE Automatic Fire Sprinklere. Inc. 00504N Automatic Fire Sprinldere, Inc. 00505N 9 1131 1 TOTAL PER FLOOR 22 TOTAL PER UNIT 22 TOTAL THIS SHEET W R R Willow Redwood Redwood NFPA 130 2010 GENERAL NOTES SCALE, NONE 00678N R R W Redwood Redwood Willow LOTS 257263 DATE SUBMITTALS By THORNESROOKE TOWNHOMES 04/17/17 QA REVIEW MPF � a � WHITE CEDAR ROAD PEND, s, SANFORD FL 32771 PEND,WA"E TAYLOR MORRISON HOMES 151 SOUTHHALL LANE, SUITE 200 Automatic Fire Sprinklers, Inc. 8 MAITLAND, FL 32751 MAIN OFFIrE — ORLANDO FLORI®A / SHEET TITLE, BIRCI-I UNIT FIRE SPRINKLER LAYOUT SPRINKLERS SPACING ,-QUANTITY--, SPRINKLERS SYMBOL MAXIMUM MINIMUM COMMENTS SYMB IST 2ND 3RD 4TH SIN SIZE K TEMP MODEL • 16X16 8 BETWEEN 8'-0' MAX SPACING OFF WALL UAO, FPB. 8 12 - R3 R3516WHITE FAX; (8T3) 630-0312 FAX: (954) 917-9424 155' RELIABLI w ® U.N.O.SPRINKLERS FT. MYERS, FL 4683 LAREDO AVE FT. MYERS, FL 33905-4924 PHONE (239) 433-3030 DEFLECTOR TO BE INSTALLED STATE LICENSES: INC SPRINKLER: 29745 NC ALARM: 29222 SP LV SC SPRINKLER 1116 1 1 R3516 T�'4�.9 175' RELIABLI SC ALARM: 3385 1"-4" BELOW COLING WHITE w 9 1131 1 TOTAL PER FLOOR 22 TOTAL PER UNIT 22 TOTAL THIS SHEET W R R Willow Redwood Redwood NFPA 130 2010 GENERAL NOTES SCALE, NONE 00678N R R W Redwood Redwood Willow LOTS 257263 DATE SUBMITTALS By THORNESROOKE TOWNHOMES 04/17/17 QA REVIEW MPF � a � WHITE CEDAR ROAD PEND, s, SANFORD FL 32771 PEND,WA"E TAYLOR MORRISON HOMES 151 SOUTHHALL LANE, SUITE 200 Automatic Fire Sprinklers, Inc. 8 MAITLAND, FL 32751 MAIN OFFIrE — ORLANDO FLORI®A / SHEET TITLE, BIRCI-I UNIT FIRE SPRINKLER LAYOUT DRAWN BY, MICKEY FERGUSON NO. DATE REVISIONS BY 222 CAPITOL COURT OCOEE, FLORIDA 34761 PHONE: (407) 656-3030 FAX: (407) 656-8026 DATE, 1 A )K )K JACKSONVIll FL TAMPA. F1_ POMPANO BEACH, R. CONTRACT ° 858_28 11326 DISTRIBUTION AVE WEST JACKSONVILLE_ FL 32256-2745 PHONE (904) 266-3030 3226 CHERRY PALM DRIVE TAMPA. FL 33619-6337 PHONE (813) 630-0303 3121 NW 16TH TERRACE POMPANO BEACH, FL 33064-1408 PHONE: (954) 917-3030 FPB. 1OCCUPANCYi CONSTRUCTION TYPE, V -B - R3 FAX (904) 268-0724 FAX; (8T3) 630-0312 FAX: (954) 917-9424 FT. MYERS, FL 4683 LAREDO AVE FT. MYERS, FL 33905-4924 PHONE (239) 433-3030 CONCORD, NC 4370 MOTORSPORT DRIVE CONCORD, NC 28027-8977 PHONE (704) 782-3032 STATE LICENSES: INC SPRINKLER: 29745 NC ALARM: 29222 SP LV SC SPRINKLER 1116 FAX: (239) 433-3263 FAX (704) 795-6638 SC ALARM: 3385 DRAWN BY, MICKEY FERGUSON TOTAL A/S, 128 DATE, APRIL 6, 2017 CITY OF SANFORD CONTRACT ° 858_28 CENTER OF TILE JOB? U YES NO I CENTER ON FIXTURES JOB? YES JNO SHEET r FPB. 1OCCUPANCYi CONSTRUCTION TYPE, V -B - R3 F DESIGN AREA #R-1 IST FLOOR UNIT R FAMILY ROOM COMPARTMENT DESA PER NEPA 130, MID EDITION, SECTION SAR RI 20' X 20' SPACING 20,0 GPM @ 16.7 PSI R2 20' X 20' SPACING 20,0 GPM @ 16,7 PSI W�E k. 00853N n.ck ra. swdd.,.. Storage , - Lanai No A/S No A/S I — D�2o ______ RiT R1 �-, L_ 2 LJ -Alco Ve� 11 Family Room J L�J LTJ 14_7 laq_ Ftw Caf e 9'-4" Clg, ! o ry `ZD 202 RA � 20� ---------------------- R2 Kitchen 9'-4" Mg 2�a ,o Cafe _ lac Pa'R,jt� \' ,, 4q F — —� - _ ------ 9'-4" Mg. Garage IF 11 II No A/S 9'-4' C1g. i h i lel IT II U 11 et�`yeS ee� �e hex TR Q See DR • 1'l 1S 8'-0" Lintel No A/S 9'-4' Mg, ii Cw I Jowaer 24,6 Sq F�l Foyer No A/S ------ 9' C Cog, ----- Porch -- wNo A/S 1ST FLOOR 2ND F z- �- 0 4- 81 REDWOOD UNIT FIRE PROTECTION PLAN (1,943 SQ. FT.) WATER SUPPLY INFORMATION SCALE 1/4' = 1' ACTUAL pRpJr� OR EXTRAPOLATED (AS REVD BY AHJ) FIRE PUMP HAZARD CLASS SIZE, GPM @ PSI SIZE %i' IIvL:PC�Ft C'�\.N 1' OVVNEFt I:NFORNIAI':ION CTR�IP:�IIC.S E:LF_-;NIF;N'TS NOTE FIRE GROSPRINKLER CONSTRUCTION DRAWINGS AND SHOP DRAWINGS MAY INCLUDE s BACCfURAL, DRAWINGS DS GRAPHICS BORROWED FROM THE ARCHITECTURAL, CiVli, THISDRAWING A' N ACCEPTANCE F THE CURRENTLY ADOPTED DRA ! G TS BASED ON THE OWNER'S CCE CED E 2' EDITION (EITHER STATE OR LOCAL) OF NFPA 25 AS THE APPLICABLE STANDARD FOR STRUCTURAL, OR MEP DRAWINGS. THESE REFERENCE BACKGROUND ELEMENTS ARE FOR WI 11326 OISTRJBUTION AVE WEST 3226 CHERRY PALM DRIVE 3121 NW 16TH TERRACE JACKSONYIL FL 32255-2745 TAMPA, FL 33519-6337 POMPANO BEACH, FL 33064-1408 THE INSPECTION, TESTING AND MAINTENANCE OF WATER BASED FIRE PROTECTION CON, GENERAL INFORMATION OR CONTEXT ONLY AND THE FIRE SPRINKLER ENGINEER DOES FLOW IN GPM SYSTEMS. PER SECTION 4.1, THE RESPONSIBILITY FOR PROPERLY MAINTAINING Fl NOT ACCEPT ANY RESPONSIBILITY FOR THESE ELEMENTS. THE FIRE SPRINKLER TIME OF TEST WATER BASED FIRE PROTECTION SYSTEM SHALL BE THAT OF THE OWNER, IF THE I ENGINEER IS ONLY RESPUNSIBLE FOR THOSE PORTIONS OF THE FIRE SPRINKLER 36 PSI BUILDING OWNER HAS NOT RECEIVED A COPY OF THIS PAMPHLET AND/OR IS NOT i DRAWINGS DEPICTING FIRE SPRINKLER SCOPES OF WORK. REFER TO APPROVED TEST PROVIDED BY FAMILIAR WITH THE OPERATION AND MAINTENANCE OF THIS SYSTEM, PLEASE CONTACT ARCHITECTURAL, STRUCTURAL, MEP OR CIVIL DRAWINGS FOR AUTHORITATIVE TEST HYDRANT LOCATED ON WHITE CEDAR ROAD THE NEAREST OFFICE OF WAYNE AUTOMATIC FIRE SPRINKLERS, INC. EXPRESSIONS OF BACKGROUND INFORMATION THAT MAY BE UTILIZED IN FIRE GPM REWO @ HYD 47,1 SPRINKLER DRAWINGS OR DETAILS ELEVATION @ HIGHEST SPRINKLER 9'-4' FAX (239) 433-3263 FAX: (704) 795-6836 CPVC C0_MPA'T'IBIL'FY NO`P.ICE N/A CPVC FIRE SPRINKLER PIPING SYSTEMS HAVE BEEN USED SUCCESSFULLYFOR MORE DOMESTIC DEMAND 5 GPM THAN 20 YEARS IN NEW CONSTRUCTION, RE -PIPE AND REPAIR. CPVC PRODUCTS ARE IDEALLY SUITED FOR THESE APPLICATIONS DUE 'TO THEIR OUTSTANDING CORROSION RESISTANCE OCCASIONALLY, HOWEVER, CPVC CAN BE DAMAGED BY CONTACT WITH CHEMICALS FOUND IN SOME CONSTRUCTION MATERIALS (IE, SOME WIRES, FLUX, PETROLEUM BASED PRODUCTS, ETC.) AND ANCILLARY PRODUCTS SUCH AS THREAD ' SEALANTS, LEAK DETECTORS, FIRESTUPS, ETC, ANY PRODUCT THAT COMES IN 110— ' CONTACT WITH CPVC SPRINKLER PIPE MUST BE EVALUATED IN ACCORDANCE WITH TOTAL PER FLOOR TOTAL PER UNIT TOTAL THIS SHEET 17 68 THE SYSTEM COMPATIBILITY PROGRAM AS FOUND AT WWW.SYSTEMCOMPATIBLE.COM Q COPYFtIa11 L' ALL DOCUMENTS,INCLUDING ORIGINAL DRAWINGS, SPECIFICATIONS, FIELD NOTES, ESTIMATES AND DATA, INCLUDING CUMPUTER PROGRAMS PURSUANT TO THIS PROJECT 71 ARE AND WILL REMAIN THE PROPERTY OF WAYNE AUTOMATIC FIRE SPRINKLERS, INC. N (WAFS) AS INSTRUMENTS OF SERVICE, THEY ARE NOT INTENDED, MOR REPRESENTED TO BE SUITABLE FOR RE -USE BY THE CLIENT, OR OTHERS, ON EXTENSION OF THIS r -I PROJECT, OR FOR ANY OTHER PROJECT. ANY REUSE, OR ADAPTATION OF THE INFORMATION CONTAINED HEREIN, WITHOUT SPECIFIC WRITTEN PERMISSION FROM WAFS WILL BE AT THE CLIENTS SOLE RISK, WITHOUT LIABILITY, OR LEGAL EXPOSURE TO WAFS, AND WILL ENTITLE WAFS TO FURTHER COMPENSATION AT RATES TO BE O AGREED ON BETWEEN WAFS AND THE CLIENT. THE CLIENT SHALL ALSO INDEMNIFY CV AND HOLD WAFS HARMLESS FROM ANY AND ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES, INCLUDING ATTORNEYS FEES RESULTING FROM ANY SUCH PERMISSIONS. Cn ri r -I WATER SUPPLY INFORMATION DESIGN SYSTEM / AREA # ACTUAL pRpJr� OR EXTRAPOLATED (AS REVD BY AHJ) FIRE PUMP HAZARD CLASS SIZE, GPM @ PSI SIZE %i' STATIC PRESSURE 65 PSI MODEL RELIABLE MODEL Fl RES, PEND, WHITE W/ RECESSED ESCS, RELIABLE MODEL Fl RES, PEND. WHITE W/ RECESSED ESCS. HYDRANT ELEV, 2' RESIDUAL PIRES= 55 PSI 11326 OISTRJBUTION AVE WEST 3226 CHERRY PALM DRIVE 3121 NW 16TH TERRACE JACKSONYIL FL 32255-2745 TAMPA, FL 33519-6337 POMPANO BEACH, FL 33064-1408 DATE OF TEST 10/11/11 FLOW IN GPM 1000 GPM PHONE (904) 2B8-3030 PHONE: (813) 530-0303 PHONE: (954) 917-3030 FAX (904) 269-0724 FAX: (813) 630-0312 FAX: (954) 917-9424 TIME OF TEST NO AM PITOT READIMG 36 PSI NUMBER OF PORTS FLOWED I TEST PROVIDED BY WAYNE AUTOMATIC FIRE SPRINKLERS, INC, HYDRANT LOCATION OR NUMBER TEST HYDRANT LOCATED ON WHITE CEDAR ROAD DESIGN CRITERIA DESIGN SYSTEM / AREA # R-1 2N D 9 1 BY HAZARD CLASS NFPA 13D SIZE %i' K 4,9 4,9 # OF SPRINKLERS IN DESIGN AREA MODEL RELIABLE MODEL Fl RES, PEND, WHITE W/ RECESSED ESCS, RELIABLE MODEL Fl RES, PEND. WHITE W/ RECESSED ESCS. &0 1 CITY OF SANFORD MINIMUM DENSITY 05 11326 OISTRJBUTION AVE WEST 3226 CHERRY PALM DRIVE 3121 NW 16TH TERRACE JACKSONYIL FL 32255-2745 TAMPA, FL 33519-6337 POMPANO BEACH, FL 33064-1408 DESIGN AREA S.F. 2 SPRKS I CENTER ON FIXTURES JOB? F] YES — NO PHONE (904) 2B8-3030 PHONE: (813) 530-0303 PHONE: (954) 917-3030 FAX (904) 269-0724 FAX: (813) 630-0312 FAX: (954) 917-9424 PSI RUT @ BR 40,9 FT. MYEM, FL 4683 LAREDO AVE. CONCOIRO, INC 4370 MOTORSPORT DRIVE GPM REQ'D @ BR 42,1 PSI REQT @ HYD 57,8 FT. MYERS, FL 33905-4924 PHONE: (239) 433-3030 GPM REWO @ HYD 47,1 ELEVATION @ HIGHEST SPRINKLER 9'-4' FAX (239) 433-3263 FAX: (704) 795-6836 �INSlDE/OUTSIDE N/A DOMESTIC DEMAND 5 GPM SPRINKLERS SPACING SYMBOL MAXIMUM MINIMUM COMMENTS © 1616- 8' BETWEEN 8'-0' IMAX SPACING OFF WALL U.N.O. U.N.O.SPRINKLERS DEFLECTOR TO BE INSTALLED ® 1'-4" BELOW CEILING F�— TO SPRINKLER SYSTEM SEE UNIT PLANS FOR CONTINUATION jTx 6' 120VAC BELL W/WEATHERPROOF BACK BOX LOCATE ON OUTSIDE WALL OF WOOD FLOOR TRUSS BUILDING (WIRED BY OTHERS) �— 3' SPLIT RING HANGER 3/8' A,T,R, & HILTI DROP—IN ANCHOR U W X 3' X V CPVC REDUCING TEE-----. W x W x V CPVC REDUCING TEE W/ NO SPARE SPRINKLERS �' x V CPVC SPIG ADAPTER---- REQUIRED PER NEPA 13D GALV, PLUG AND 300 PSI WATER GAUGE & 3 -WAY VALVE 3`xWxl' CPVC REDUCING TEE W/POTTER GLUE IN FLOW SWITCH (WIRED BY OTHERS) CPVC BALL VALVE 14' CPVC CHECK VALVE --fir �c > o_ C.) W COUP & 1ST X3" CPVC BUSHING B CPVC 90° OUT WALL TO VA' SPIGOT ADAPTER OVERHEAD PERMIT TO / & SAWN HEAD START AT 1'-0" A.F.F. TYPICAL SPRINKLER --r...-.---- DYNAFLOW SLEEVE---- FROM LEEVE)FROM SUPPLY 1 1/2' PIPE ROTATED FOR CLARITY BY OTHERS CPVC TYPICAL EXPOSED CPVC FIRE SPRINKLER RISER r Fire Sprinklere, Inc. TYPICAL LIGHT FIXTURE Sf 36' MINIMUM'S "IN ROOMS/COMPARTMENTS 400 CU, FT, OR LESS, SPRINKLERS MAY BE PLACED REGARDLESS OF LOCATION OF OBSTRUCTIONS, NFPA 13R G 13D SPRINKLER CLEARANCE W/ LIGHT FIXTURE �IAYTjE SCALE, NONE Automatic Fire Sprinklere, Inc. 00504N r---QUANTITY-1 SPRINKLERS SYM D (� IST 6 1 2N D 9 1 BY 222 CAPITOL COURT OCOEE, FLORIDA 34761 PHONE: (407) 656-3030 FAX: (407) 656-8026 SIN R3516 R3516 SIZE %i' K 4,9 4,9 TEMP 155' 175' MODEL RELIABLE MODEL Fl RES, PEND, WHITE W/ RECESSED ESCS, RELIABLE MODEL Fl RES, PEND. WHITE W/ RECESSED ESCS. &0 1 CITY OF SANFORD CONTRACT A 11326 OISTRJBUTION AVE WEST 3226 CHERRY PALM DRIVE 3121 NW 16TH TERRACE JACKSONYIL FL 32255-2745 TAMPA, FL 33519-6337 POMPANO BEACH, FL 33064-1408 CENTER OF TILE JOB? C J YES _ NO I CENTER ON FIXTURES JOB? F] YES — NO PHONE (904) 2B8-3030 PHONE: (813) 530-0303 PHONE: (954) 917-3030 FAX (904) 269-0724 FAX: (813) 630-0312 FAX: (954) 917-9424 FPR. 1 FT. MYEM, FL 4683 LAREDO AVE. CONCOIRO, INC 4370 MOTORSPORT DRIVE STATE LICENSES: NC SPRMER: 29745 FT. MYERS, FL 33905-4924 PHONE: (239) 433-3030 CONCORD, NC 28027-6977 PHONE: (704) 782-3032 NC ALARM: 29222 SP LV SC SPRINKLER 1116 FAX (239) 433-3263 FAX: (704) 795-6836 I I I 7 110— TOTAL PER FLOOR TOTAL PER UNIT TOTAL THIS SHEET 17 68 DATE SUBM ITTALS 04/17/17 7/ QA REVIEW SCALE, NONE • DESIGN AND INSTALLATION TO BE IN ACCORDANCE WITH 2010 EDITION OF NFPA 130, • DESIGN AND INSTALLATION TO BE IN ACCORDANCE WITH ALL APPLICABLE LOCAL AND STATE CODES. • ALL PIPE AND FITTINGS USED ON THIS PROJECT TO BE IN ACCORDANCE WITH APPLICABLE CODES AND WAFS STANDARDS. SEE PIPE AND FITTINGS GENERAL NOTES (WAFS DETAIL #00593N). • ALL HANGERS SHALL BE DESIGNED AND INSTALLED IN ACCORDANCE WITH NFPA 130 AND THEIR LISTING. • ALL PENETRATIONS THROUGH RATED BUILDING ASSEMBLIES SHALL BE SEALED WITH FIRE CAULK IN ACCORDANCE WITH DETAILS PROVIDED, WAFS POLICY IS TO USE HILTI FS ONE OR STI LCI. • UNDERGROUND MAINS AND LEAD-INS SHALL BE FLUSHED AND SIGNED TEST CERTIFICATES PROVIDED BEFORE A CONNECTION IS MADE TO THE SPRINKLER SYSTEM. TM WHEN SYSTEM IS FED USING PLUMBING SERVICE, PIPING SHALL STILL BE FLUSHED PRIOR TO CONNECTING THE SPRINKLER SYSTEM. • ALL PIPING SHALL BE INSPECTED AND APPROVED BY PROPER AUTHORITIES PRIOR TO COVERING WITH DRYWALL. COPIES OF SIGNED TEST CERTIFICATES ARE TO BE FORWARDED TO THE PROPER RECIPIENTS, • ALL SYSTEMS SHALL BE TESTED AT 200 PSI FOR 2 HOURS PER WAFS STANDARDS. • ALL SOFFITS REQUIRED TO CONCEAL SPRINKLER PIPING ARE BY OTHERS. • ALL WIRING OF DEVICES IF PROVIDED (FLOW SWITCHES, TAMPER SWITCHES, ETC) IS BY OTHERS. it VALVES SHALL NOT BE REQUIRED TO BE MONITORED PER FLORIDA BUILDING CODE 903.4 (1). • LOCAL WATERFLOW ALARMS SHALL BE PROVIDED ON ALL SPRINKLER SYSTEMS IN HOMES NOT EQUIPPED WITH SMOKE ALARMS OR SMOKE DETECTORS IN ACCORDANCE WITH NFPA 72. NATIONAL FIRE ALARM CODE. • CONNECTION OF SPRINKLER DEVICES TO THE BUILDING ALARM OR MONITORING SYSTEM, IF PROVIDED, IS BY OTHERS. • ALL PAINTING OF PIPE AS REQUIRED IS BY OTHERS. Mr ALL INSULATION REQUIRED FOR FREEZE PROTECTION OF SPRINKLER PIPING IS BY OTHERS. • HEATING OF ROOMS TO MAINTAIN TEMPERATURES OF 40 DEGREES OR GREATER IS BY OTHERS. • SPRINKLERS SHALL NOT BE INSTALLED PRIOR TO THE FITTINGS BEING CEMENTED IN PLACE. AT ALL SPRINKLERS IN DWELLING UNITS SHALL BE UL LISTED OR FM APPROVED RESIDENTIAL SPRINKLERS. • SPARE SPRINKLERS WILL NOT BE PROVIDED AS THEY ARE NOT REQUIRED BY NFPA 13D. • REFER TO SPACING NOTES ON PLANS FOR MAXIMUM CALCULATED SPACING ALLOWANCES. • SPRINKLERS SHALL BE INSTALLED IN ALL AREAS EXCEPT AS FOLLOWS: o BATHROOMS WHERE THE AREA DOES NOT EXCEED 55 SQ FT. o CLOTHES CLOSETS, LINEN CLOSETS AND PANTRIES WITHIN THE DWELLING UNITS THAT DO NOT EXCEED 24 SQUARE FEET, THE LEAST DIMENSION DOES NOT EXCEED 3 FEET, AND THE WALLS AND CEILINGS ARE SURFACED WITH NONCOMBUSTIBLE OR LIMITED -COMBUSTIBLE MATERIALS AS DEFINED BY NFPA 220, STANDARD ON TYPES OF BUILDING CONSTRUCTION. o ANY GARAGES, OPEN ATTACHED PORCHES, CARPORTS AND SIMILAR STRUCTURES. o ATTICS, PENTHOUSE EQUIPMENT ROOMS, ELEVATOR MACHINE ROOMS, CONCEALED SPACES DEDICATED EXCLUSIVELY TO AND CONTAINING ONLY DWELLING UNIT VENTILAION EQUIPMENT, FLOOR/CEILING SPACES, ELEVATOR SHAFTS, CRAWL SPACES, AND OTHER CONCEALED SPACES THAT ARE NOT USED OR INTENDED FOR LIVING PURPOSES AND DO NOT CONTAIN FUEL -FIRED EQUIPMENT, o COVERED UNHEATED PROJECTIONS OF THE BUILDING AT ENTRANCES/EXITS AS LONG AS THERE IS ANOTHER MEANS OF EGRESS FROM THE DWELLING UNIT. o SPRINKLERS SHALL NOT BE REQUIRED FOR CEILING POCKETS THAT MEET THE FOLLOWING CONDITIONS: 1. THE TOTAL VOLUME OF UNPROTECTED CEILING POCKET DOES NOT EXCEED 100 CU. FT. 2. THE ENTIRE FLOOR UNDER THE UNPROTECTED CEILING POCKET IS PROTECTED BY THE SPRINKLERS AT THE LOWER CEILING ELEVATION. 3. EACH UNPROTECTED CEILING POCKET IS . SEPARATED FROM ANY ADJACENT UNPROTECTED CEILING POCKET BY A MINIMUM OF 10 FT. HORIZONTAL DISTANCE. 4. THE INTERIOR FINISH OF THE UNPROTECTED CEILING POCKET IS NONCOMBUSTIBLE OR LIMITED -COMBUSTIBLE MATERIAL. 5. SKYLIGHTS NOT EXCEEDING 32 SQ. FT. SHALL BE PERMITTED TO HAVE A PLASTIC COVER. #r WAFS TO PROVIDE ALL REQUIRED SIGNAGE PER NFPA 130 INCLUDING BUT NOT LIMITED TO VALVES, HYDRAULIC PLACARDS, AND INSPECTION TAGS AS REQUIRED BY FS 633. • DEVICES THAT RESTRICT THE FLOW OR DECREASE THE PRESSURE OR AUTOMATICALLY SHUT OFF THE WATER TO THE SPRINKLER SYSTEM, SUCH AS WATER SOFTENERS, FILTRATION SYSTEMS, AND AUTOMATIC SHUTOFF VALVES, SHALL NOT BE ADDED TO THIS SYSTEM WITHOUT A REVIEW OF THE FIRE SPRINKLER SYSTEM BY A FIRE PROTECTION SPECIALIST. (DW -1 'm�\07NFPA 13D 2010 GENERAL NOTES A� SCALE, NONE Automatic Fire Sprlinkilws, km 00678N (ANY MODEL IS ACCEPTABLE PROVIDED PLAN VIEW OF BLADES IS 50% OPEN) NFPA 13R G 130 SPRINKLER CLEARANCE W/ CEILING FAN E SCALE, NONE Fire Sprinklere, Inc. 00505N LOTS 257-263 BY TH ORN S E RO OKE T OWN BIOMES MPF s WHITE CEDAR ROAD SANFORD FL 32771 WAYNE TAYLOR MORRISON HOMES 151 SOUTHHALL LANE, SUITE 200 Automatic Fire Sprinklers, Inc. MAITLAND, FL 32751 ot MAIN OFFICE — ®RLANDD FLORIDA SHEET TITLE, REDWOOD UNIT FIRE SPRINKLER LAYOUT DRAWN BYi MICKEY FERGUSON NO. DATE REVISIONS BY 222 CAPITOL COURT OCOEE, FLORIDA 34761 PHONE: (407) 656-3030 FAX: (407) 656-8026 DATE, APRIL 6, 2017 JACICBONVLLE, FL TAMPA, FL POMPANO BEACH, FL &0 1 CITY OF SANFORD CONTRACT A 11326 OISTRJBUTION AVE WEST 3226 CHERRY PALM DRIVE 3121 NW 16TH TERRACE JACKSONYIL FL 32255-2745 TAMPA, FL 33519-6337 POMPANO BEACH, FL 33064-1408 CENTER OF TILE JOB? C J YES _ NO I CENTER ON FIXTURES JOB? F] YES — NO PHONE (904) 2B8-3030 PHONE: (813) 530-0303 PHONE: (954) 917-3030 FAX (904) 269-0724 FAX: (813) 630-0312 FAX: (954) 917-9424 FPR. 1 FT. MYEM, FL 4683 LAREDO AVE. CONCOIRO, INC 4370 MOTORSPORT DRIVE STATE LICENSES: NC SPRMER: 29745 FT. MYERS, FL 33905-4924 PHONE: (239) 433-3030 CONCORD, NC 28027-6977 PHONE: (704) 782-3032 NC ALARM: 29222 SP LV SC SPRINKLER 1116 FAX (239) 433-3263 FAX: (704) 795-6836 SC ALARM: 3385 DRAWN BYi MICKEY FERGUSON TOTAL A/Sl 128 DATE, APRIL 6, 2017 &0 1 CITY OF SANFORD CONTRACT A 85828 CENTER OF TILE JOB? C J YES _ NO I CENTER ON FIXTURES JOB? F] YES — NO SHEET # FPR. 1 CONSTRUCTION TYPE, OCCUPANCYR 3 P Fv L • - Lrl O Family Room T-4" Clg. LTJ LTJ �II II li It fill .5.2 Sqft-- Cg�_4' R F 1 Lanai No A/S Cafe 9'-4' Clg1 0-8l U .I Kitchen PQwde II 9'-4' Clg, ..9. q Ft I l No k/S 9'-4' Crg ll - - 5�__ Garage No A/S 9'-4" Mg, F2 D 6 �= fro SCALE 1/4' = V EXTRAN'(1.AIEED (AS REVD BY AHJ) o� FLORIDA 34781 (407) 556-EI025 SIZE, GPM @ PSI NFPA 13D o� 65 PSI IiVIPOFZT�LN�L' OWN.E;R INF'OF2_NIAl'ION 04, 00 n L-=----' =-zJ WIC Owner's Suite 8'-0" Clg. 76.5 Sq Ft Y F-. -I L -1 T -O" Cog L 1 I DESIGN AREA #W-2 2ND FLOOR UNIT W OWNER'S SUITE COMPARTMENT DESIGN PER NFPA 13D, 2010 EDITION, SECTION 8.1.2 W3 20' X 20' SPACING 20,0 GPM @ 16,7 PSI 00853N Autao,ek Fr. `+P.NE Ln �L 2'-3' Zp O I DESIGN AREA #W-1 Min, \ ° I END FLOOR UNIT W COMMON AREA ws 2 I COMPARTMENT DESIGN PER NFPA 13D, • I i • 0>11._ _ _ I 2010 EDITION. SECTION 8.1.2 16' X 16' SPACING s 2'-3- F4.1 -1 I 13,0 GPM @ 7,0 PSI L'r� Min, W2 16' X 16' SPACING — — — — — — - 13.0 GPM @ 7,0 PSI LYN 1E 111 A t�. ,ll 00853N ------------ ------ --- Toile t--� ----- Lin n I - 18,6 Sq- I -_--- oA/ Nc A/S II Laundry ---- 1 '01 ---'=0" --Clg 189.2 Sq Ft • c,� (; 2T 8'-0' Mg - I • Linen • Owner's Bath o' /S Chase it II it ii _�_;Ill Loft vl� 8'-0" Clg, if 1 fill M-0 it ll �Cif 11 _ a_tr1 xo . Hall 'Bathroom #1 200 1 —=33,0---Sq-r t C� 2° CEJ M 0oBathroom #2 - 30,1 Sq F1 � � \� No A/S Bedroom #2 Clo= ­��� II II 814" Cl 06 I II II Ii.I.C. TTW < ♦' Q e 36� q aFt BW Z 8'r0" Mg. �{ L^ II u, o Bedroom #3 8'-0" Mg, 1ST FLOOR 2NO.FLOOR j WILLOW UNIT FIRE PROTECTION PLAN 2' i' 0 4' 8' � Ill 1 1 (2,059 SQ. FT.) WATER SUPPLY INFORMATION SYSTEM / DESIGN AREA SCALE 1/4' = V EXTRAN'(1.AIEED (AS REVD BY AHJ) FIRE PUMP FLORIDA 34781 (407) 556-EI025 SIZE, GPM @ PSI NFPA 13D STATIC ,RT' PRESp _ 65 PSI IiVIPOFZT�LN�L' OWN.E;R INF'OF2_NIAl'ION C}FLAPF-IIC:S EL,ENLFINI'S NOTE 2 RESIDUAL PRESM THIS DRAWING 1S BASED ON THE OdNERS ACCEPTAH � Or E FIRE ER CONSTRUCTION DRAWINGS AND SHOP DRAWINGS NAY INCLUDE BACKGROUND DRAWINGS OR GRAPHICS BORROWEDFROM THE ARCHITECTURAL, CIVIL, DATE OF TEST 10/11/17 EDITION (EITHER STATE OR LOCAL) OF NFPA 25 AS THE APPLICABLE STANDARD FOR STRUCTURAL, OR MEP DRAWINGS. THESE REFERENCE BACKGROUND ELEMENTS ARE FOR PHONE: (954) 917-3030 TIME OF TEST THEINSPECTION, TESTING AND MAINTENANCE OF WATER BASED FIRE PROTECTION GENERAL INFORMATION OR CONTEXT ONLY AND THE FIRE SPRINKLER ENGINEER DOES 36 PSI NUMBER OF PORTS FLOWED SYSTEMS. PER SECTION 4.1, THE RESPONSIBILITY FOR PROPERLY MAINTAINING A NOT ACCEPT ANY RESPONSIBILITY FOR THESE ELEMENTS. THE FIRE SPR1tCKLER WAYNE AUTOMATIC FIRE SPRINKLERS, INC, HYDRANT LOCATION OR NUMBER WATER BASED FIRE PROTECTION SYSTEM SHALL BE THAT OF THE OWNER. IF THE ENGINEER IS ONLY RESPONSIBLE FOR THOSE PORTIONS OF THE FIRE SPRINKLER 26,7 2010 BUILDING OWNER HAS NOT RECEIVED A COPY OF THIS PAMPHLET AND/OR IS NOT DRAWINGS DEPICTING FIRE SPRINKLER SCOPES OF WORK. REFER TO APPROVED PSI REQ D e HYD 433 FAMILIAR WITH THE OPERATION AND MAINTENANCE OF THIS SYSTEM, PLEASE CONTACT ARCHITECTURAL, STRUCTURAL, MEP OR CIVIL DRAWINGS FOR AUTHORITATIVE GPM REQ'D e HYD THE NEAREST OFFICE OF WAYNE AUTOMATIC FIRE SPRINKLERS, INC. P N FBACKGROUND INF RMAT ON THAT MAY BE UTILIZED IN FIRE EX RESSID S O 0 I L ELEVATION a HIGHESTSPRI KLER SPRINKLER DRAWINGS OR DETAILS INSE SIDE/WTSIDE N/A jCPVC CONIPA'IIT3ILIPY NOTICE DOMESTIC DENAND 5 GPM CPVC FIRE SPRINKLER PIPING SYSTEMS HAVE BEEN USED SUCCESSFULLY FOR MORE THAN 20 YEARS IN NEW CONSTRUCTION, RE -PIPE AND REPAIR. CPVC PRODUCTS ARE IDEALLY SUITED FOR THESE APPLICATIONS DUE TO THEIR OUTSTANDING CORROSION RESISTANCE. OCCASIONALLY, HOWEVER, CPVC CAN BE DAMAGED BY CONTACT WI -11 CHEMICALS FOUND IN SOME CONSTRUCTION MATERIALS (IE, SOME WIRES, FLUX, PETROLEUM BASED PRODUCTS, ETC,) AND ANCILLARY PRODUCTS SUCH AS THREAD SEALANTS, LEAK DETECTURS, FIRESTOPS, ETC, ANY PRODUCT THAT COMES IN CONTACT WITH CPVC SPRINKLER PIPE MUST BE EVALUATED IN ACCORDANCE WITH THE SYSTEM COMPATIBILITY PROGRAM AS FOUND AT WWW,SYSTEMCOMPATIDLE,COM Q C O P Y.Ft I Ci F -I 1, ALL DOCUMENTS, INCLUDING ORIGINAL DRAWINGS, SPECIFICATIONS, FIELD NOTES, N ESTIMATES AND DATA, INCLUDING COMPUTER PROGRAMS PURSUANT TO THIS PROJECT ARE AND WILL REMAIN THE PROPERTY OF WAYNE AUTOMATIC FIRE SPRINKLERS, INC. N (WAFS) AS INSTRUMENTS OF SERVICE. THEY ARE NOT INTENDED, NOR REPRESENTED TO BE SUITABLE FOR RE -USE BY THE CLIENT, OR OTHERS, ON EXTENSION OF THIS ri PROJECT, OR FOR ANY OTHER PROJECT. ANY REUSE, OR ADAPTATION OF THE rIINFORMATION CONTAINED HEREIN, WITHOUT SPECIFIC WRITTEN PERMISSION FROM WAFS WILL BE AT THE CLIENTS SOLE RISK, WITHOUT LIABILITY, OR LEGAL EXPOSURE TO WAFS, AND WILL ENTITLE WAFS TO FURTHER COMPENSATION AT RATES TO BE CNCN AGREED ON BETWEEN WAFS AND THE CLIENT. THE CLIENT SHALL AL S❑ INDEMNIFY AND HOLD WAFS HARMLESS FROM ANY AND ALL CLAIMS, DAMAGES, LOSSES AND 1 EXPENSES, INCLUDING ATTORNEYS FEES RESULTING FROM ANY SUCH PERMISSIONS, WATER SUPPLY INFORMATION SYSTEM / DESIGN AREA ACTUAL EXTRAN'(1.AIEED (AS REVD BY AHJ) FIRE PUMP FLORIDA 34781 (407) 556-EI025 SIZE, GPM @ PSI NFPA 13D STATIC ,RT' PRESp _ 65 PSI POMPANO BEACH, IFIL HYDRANT ELEV. Y EV 2 RESIDUAL PRESM 55 PSI 3121 NW 16TH TERRACE POMPANO BEACH. FL 33064-1408 DATE OF TEST 10/11/17 FLOV IN GPM 1000 GPM PHONE: (954) 917-3030 TIME OF TEST 8100 AM PITOT READING 36 PSI NUMBER OF PORTS FLOWED I TEST PWIIDED BY WAYNE AUTOMATIC FIRE SPRINKLERS, INC, HYDRANT LOCATION OR NUMBER TEST HYDRANT LOCATED ON WHITE CEDAR ROAD Q4 V1/,I I. C. 41,0 Sq Ft — — -j DESIGN CRITERIA SYSTEM / DESIGN AREA W-1 W-2 222 CAPITOL COURT OCOEE, PHONE: (407) 656-3030 FAX: FLORIDA 34781 (407) 556-EI025 HAZARD CLASS NFPA 13D NFPA 13D TAMPA, FL POMPANO BEACH, IFIL # OF SPRINKLERS IN DESIGN AREA CITY OF SANFORD 1 3228 CHERRY PALM DRIVE TAMPA, FL 33619-8337 3121 NW 16TH TERRACE POMPANO BEACH. FL 33064-1408 MINIMUM DENSITY ,05 05 PHONE: (813) 630-0303 PHONE: (954) 917-3030 j DESIGN AREA S.F. 2 SPRKS I SPRKS FAX: (954) 917-9424 OCCUPANCY, R-3 PSI REQ'D a BW 31,4 40.7 STATE LICENSES: NC SPRINKLER: 29745 GPM REQ'D e BW 26,7 2010 NC ALAFm 29222 SP LV SC SPRINKLER 1116 PSI REQ D e HYD 433 50.6 SC ALARM: 3386 GPM REQ'D e HYD 31,7 25,0 ELEVATION a HIGHESTSPRI KLER INSE SIDE/WTSIDE N/A N/A DOMESTIC DENAND 5 GPM 5 GPM TO SPRINKLER SYSTEM � 6' 120VAC BELL W/WEATHERPROOF BACK Tx SEE UNIT PLANS FOR CONTINUATION BOX LOCATE ON OUTSIDE WALL OF WOOD FLOOR TRUSS BUILDING (WIRED BY OTHERS) - 5 1!I' SPLIT RING HANGER WOOD 3/8' A,T.R. & HILTI DROP-IN ANCHOR v I W X 3' X %' CPVC REDUCING TEE-`_, 1�' x 1�' x ' CPVC REDUCING TEE W/ NO SPARE SPRINKLERS ` x '' CPVC SPIG ADAPTER----- REQUIRED PER NFPA 13D GALV, PLUG AND 300 PSI WATER GAUGE & 3 -WAY VALVE 1VxI%'x1' CPVC REDUCING TEE W/POTTER GLUE IN FLOW SWITCH (WIRED BY OTHERS) -(' CPVC BALL VALVE I 1%' CPVC CHECK VALVE------ � U IV COUP & 11'xllf" CPVC BUSHING BA T(' CPVC 90' OUT WALL /- TO %'A' SPIGOT ADAPTER OVERHEAD PERMIT TO / & SAWN HEAD START AT 1'-0" A.F.F. U i DYNAFLOW SLEEVE-` FROM SUPPLY 1 1/2' PIPE ROTATED FOR CLARITY BY OTHERS If CPVC TYPICAL EXPOSED CPVC FIRE SPRINKLER RISER SCALEI NONE Automatic Fire Sprinklora, Inc. TYPICAL `- TYPICAL LIGHT SPRINKLER FIXTURE 36' MINIMUM��' 'KIN ROOMS/COMPARTMENTS 400 CU. FT, OR LESS, SPRINKLERS MAY BE PLACED REGARDLESS OF LOCATION OF OBSTRUCTIONS. NFPA 13R E 13D . SPRINKLER CLEARANCE W/ LIGHT FIXTURE SCALE, NONE Automatic Fire Sprinklere, Inc. 00504N SF • DESIGN AND INSTALLATION TO BE IN ACCORDANCE WITH 2O1Q EDITION OF NFPA 13D. • DESIGN AND INSTALLATION TO BE IN ACCORDANCE WITH ALL APPLICABLE LOCAL AND STATE CODES. • ALL PIPE AND FITTINGS USED ON THIS PROJECT TO BE IN ACCORDANCE WITH APPLICABLE CODES AND WAFS STANDARDS. SEE PIPE AND FITTINGS GENERAL NOTES (WAFS DETAIL #00593N). • ALL HANGERS SHALL BE DESIGNED AND INSTALLED IN ACCORDANCE WITH NFPA 130 AND THEIR LISTING. • ALL PENETRATIONS THROUGH RATED BUILDING ASSEMBLIES SHALL BE SEALED WITH FIRE CAULK IN ACCORDANCE WITH DETAILS PROVIDED. WAFS POLICY 15 TO USE HILTI FS ONE OR STI LCI. • UNDERGROUND MAINS AND LEAD-INS SHALL BE FLUSHED AND SIGNED TEST CERTIFICATES PROVIDED BEFORE A CONNECTION IS MADE TO THE SPRINKLER SYSTEM. • WHEN SYSTEM IS FED USING PLUMBING SERVICE, PIPING SHALL STILL BE FLUSHED PRIOR TO CONNECTING THE SPRINKLER SYSTEM. • ALL PIPING SHALL BE INSPECTED AND APPROVED BY PROPER AUTHORITIES PRIOR TO COVERING WITH DRYWALL. COPIES OF SIGNED TEST CERTIFICATES ARE TO BE FORWARDED TO THE PROPER RECIPIENTS. • ALL SYSTEMS SHALL BE TESTED AT 200 PSI FOR 2 HOURS PER WAFS STANDARDS. • ALL SOFFITS REQUIRED TO CONCEAL SPRINKLER PIPING ARE BY OTHERS. • ALL WIRING OF DEVICES IF PROVIDED (FLOW SWITCHES, TAMPER SWITCHES, ETC) IS BY OTHERS. • VALVES SHALL NOT BE REQUIRED TO BE MONITORED PER FLORIDA BUILDING CODE 903.4 (1). • LOCAL WATERFLQW ALARMS SHALL BE PROVIDED ON ALL SPRINKLER SYSTEMS IN HOMES NOT EQUIPPED WITH SMOKE ALARMS OR SMOKE DETECTORS IN ACCORDANCE WITH NFPA 72, NATIONAL FIRE ALARM CODE. • CONNECTION OF SPRINKLER DEVICES TO THE BUILDING ALARM OR MONITORING SYSTEM, IF PROVIDED, IS BY OTHERS. • ALL PAINTING OF PIPE AS REQUIRED IS BY OTHERS. • ALL INSULATION REQUIRED FOR FREEZE PROTECTION OF SPRINKLER PIPING IS BY OTHERS, • HEATING OF ROOMS TO MAINTAIN TEMPERATURES OF 40 DEGREES OR GREATER IS BY OTHERS. • SPRINKLERS SHALL NOT BE INSTALLED PRIOR TO THE FITTINGS BEING CEMENTED IN PLACE. • ALL SPRINKLERS IN DWELLING UNITS SHALL BE UL LISTED OR FM APPROVED RESIDENTIAL SPRINKLERS. • SPARE SPRINKLERS WILL NOT BE PROVIDED AS THEY ARE NOT REQUIRED BY NFPA 130. • REFER TO SPACING NOTES ON PLANS FOR MAXIMUM CALCULATED SPACING ALLOWANCES. • SPRINKLERS SHALL BE INSTALLED IN ALL AREAS EXCEPT AS FOLLOWS: o BATHROOMS WHERE THE AREA DOES NOT EXCEED 55 SQ FT. o CLOTHES CLOSETS, LINEN CLOSETS AND PANTRIES WITHIN THE DWELLING UNITS THAT 00 NOT EXCEED R4 SQUARE FEET, THE LEAST DIMENSION DOES NOT EXCEED 3 FEET, AND THE WALLS AND CEILINGS ARE SURFACED WITH NONCOMBUSTIBLE OR LIMITED -COMBUSTIBLE MATERIALS AS DEFINED BY NFPA 220, STANDARD ON TYPES OF BUILDING CONSTRUCTION. o ANY GARAGES, OPEN ATTACHED PORCHES, CARPORTS AND SIMILAR STRUCTURES. o ATTICS, PENTHOUSE EQUIPMENT ROOMS, ELEVATOR MACHINE ROOMS, CONCEALED SPACES DEDICATED EXCLUSIVELY TO AND CONTAINING ONLY DWELLING UNIT VENTILAION EQUIPMENT, FLOOR/CEILING SPACES, ELEVATOR SHAFTS, CRAWL SPACES, AND OTHER CONCEALED SPACES THAT ARE NOT USED OR INTENOED FOR LIVING PURPOSES AND DO NOT CONTAIN FUEL -FIRED EQUIPMENT, a COVERED UNHEATED PROJECTIONS OF THE BUILDING AT ENTRANCES/EXITS AS LONG AS THERE IS ANOTHER MEANS OF EGRESS FROM THE DWELLING UNIT. o SPRINKLERS SHALL NOT BE REQUIRED FOR CEILING POCKETS THAT MEET THE FOLLOWING CONDITIONS: 1. THE TOTAL VOLUME OF UNPROTECTED CEILING POCKET DOES NOT EXCEED 100 CU. FT. 2. THE ENTIRE FLOOR UNDER THE UNPROTECTED CEILING POCKET IS PROTECTED BY THE SPRINKLERS AT THE LOWER CEILING ELEVATION. 3. EACH UNPROTECTED CEILING POCKET IS SEPARATED FROM ANY ADJACENT UNPROTECTED CEILING POCKET BY A MINIMUM OF 10 FT. HORIZONTAL DISTANCE. 4. THE INTERIOR FINISH OF THE UNPROTECTED CEILING POCKET IS NONCOMBUSTIBLE OR LIMITED -COMBUSTIBLE MATERIAL. 5. SKYLIGHTS NOT EXCEEDING 32 SQ. FT. SHALL BE PERMITTED TO HAVE A PLASTIC COVER. • WAFS TO PROVIDE ALL REQUIRED SIGNAGE PER NFPA 130 INCLUDING BUT NOT LIMITED TO VALVES, HYDRAULIC PLACARDS, AND INSPECTION TAGS AS REQUIRED BY FS 633. • DEVICES THAT RESTRICT THE FLOW OR DECREASE THE PRESSURE OR AUTOMATICALLY SHUT OFF THE WATER TO THE SPRINKLER SYSTEM, SUCH AS WATER SOFTENERS, FILTRATION SYSTEMS, AND AUTOMATIC SHUTOFF VALVES, SHALL NOT BE ADDED TO THIS SYSTEM WITHOUT A REVIEW OF THE FIRE SPRINKLER SYSTEM BY A FIRE PROTECTION SPECIALIST. NFPA 130 2010 GENERAL NOTES SCALEI NONEA=AMAWRNE ■'�, ha 00678N SPRINKLERS SPACING SPRINKLERS rQUANTITY-1 i DATE SUBMITI'AI.S SYMBOL MAXIMUM MINIMUM COMMENTS SYMB IST 2ND 3N SIZE K TEMP MODEL 04/17/17 QA REVIEW ..�. • 8'-0° MAX SPACING OFF WALL LIAO, • 6 12 4.9 155' RELIABLE MODEL FI RES. PEND. � 16 z16 8 BETWEEN O R3516 � DEFLECTOR TO BE INSTALLED WHITE W/ RECESSED ESCS, b . RELIABLE MODE F U.N.O. SPRINKLERS L 1 RES. PEND, - 0 1 R 6 9 ® 11-41 B I 351 4, 175 BELOW CEILING ® � WHITE W/ RFr.FSSFO FSf.S. 6 113 1 1 TOTAL PER FLOOR 19 TOTAL PER UNIT 38 TOTAL THIS SHEET N0. I DATE REVISIONS A (ANY MODEL IS ACCEPTABLE PROVIDED PLAN VIEW OF BLADES IS 507 OPEN) NFPA 13R 6 130 SPRINKLER CLEARANCE W/ CEILING FAN E SCALE, NONE Fire Sprinklare, Inc. 00505N R R B R R Redwood Redwood Birch Redwood Redwood a MIN I 11 6, 1 0 pm—mol LOTS 257-263 BY T HR 0 NES RO OE KT OWN o HOMES MPF 6 WHITE CEDAR ROAD SANFORD FL 32771 WA"FM ITAYLOR O M RRISON H ONES 151 SOUTHHALL LANE, SUITE 200 Automatic Fire sprinklers, Inc. ` MAITLAND, FL 32751 At di MAIN OFFICE -- ORLANDO r -i nDIDA SLEET nTLE1 WILLOW UNIT FIRE SPRINKLER LAYOUT DRAWN BY, � MICKEY FERGUSON BY 222 CAPITOL COURT OCOEE, PHONE: (407) 656-3030 FAX: FLORIDA 34781 (407) 556-EI025 DATD1 JACKSONVLLF, FL TAMPA, FL POMPANO BEACH, IFIL AHJk CITY OF SANFORD 11326 DISTRIBUTION AVE WEST JACKSWILLE, FL 32256-2745 3228 CHERRY PALM DRIVE TAMPA, FL 33619-8337 3121 NW 16TH TERRACE POMPANO BEACH. FL 33064-1408 85828 PHONE (904) 268-3030 PHONE: (813) 630-0303 PHONE: (954) 917-3030 SHEET I FAX: (904) 268-0724 FAX: (813) 630-0312 FAX: (954) 917-9424 OCCUPANCY, R-3 FT. MYER$, FL 4883 LAREDO AYE. CONCORD, NC 4370 MOTORSPORT DRIVE STATE LICENSES: NC SPRINKLER: 29745 Fr. MYERS.FL 33905-4924 PHOtIE (239) 433-3030 CONCORD, NC 28027-8977 PHONE: (704) 782-3032 NC ALAFm 29222 SP LV SC SPRINKLER 1116 FAX: (239) 433-3263 FAX: (704) 795-5838 SC ALARM: 3386 DRAWN BY, � MICKEY FERGUSON TOTAL A/S1 128 DATD1 APRIL 6, 2017 AHJk CITY OF SANFORD CONTRACT If 85828 CENTER OF TILE JOB? DYES 0 NO I CENTER ON FIXTURES J0137 EYES VNO SHEET I FPW■ CONSTRUCTION TYPE, v-a OCCUPANCY, R-3