Loading...
1215 Randolph St #11-2026 - home repairPERMIT ADDRESS / CONTRACTOR ADDRESS D d do /,o SUBDIVISION �;�✓ � � U�Q2-,. PERMIT IP I �`ci 0� DATE PERMIT DESCRIPTION��Gn�- PERNIIT VALUATION PHONE NUMBEK SQUARE FOOTAGE PROPERTY OWNER ADDRESS PHONE NUMBER ELECTRICAL CONTRACTOR MECHANICAL CONTRACTO PLUMBING CONTRACTOR _ MISCELLANEOUS CONTRACTOR PERMIT NUMBER FEE MISCELLANEOUS CONTRACTOR PERMIT NUMBER FEE n O d 8" Overhang Simpson H2 w/ 3 - 3/16" Tap Cone to Concrete PROPOSED ROOF PLAN 2' " 3 -U All Walls to be wood 2x4 @ 16" O.C.'s .Exist. Concrete Floor I l Ov Light Box II \ 14'-0" L � 1lUv Switch I 2 1 lUv Light Box_(� 1" D W W1 -I Exist, Window Exist. Electrical To Remain Pl1 OPOSED .ULOOR PLAN 5" Facia Exist. Concrete Floor No Roof ---Rollow Core Door Exist, Electric Panel to Remain Replace Truss Tails and Soffit this area Exist. 8' S.G.D. 2" x 4'x T Extensions to replace Soffit matching Existing Residence - Attach to Existing Tuss w/ 6 l Od nails 1/2" Ply. Decking Nailed to if 6" Metal Flashing under 9233 Roll Roofing exist. Roofing and over 15F4 Felt Paper Proposed Roll Roofing 1/2„ Exterior Ply. l IOptional 1/2” Drywall Exist. AnchorsT7 f I�_Cut Truss Tails back to Btk. Wall and R19 Insulation l I _Simpson 1r122 Tap Con to Blk. bull l I ,v/ (3) 3/16" x I' Tap Cons. l I 8'-0" I Optional 1/2" drywall I ( I and RI I Insulation l ----- --!-4"Step -------------------------=_ 1 �, 1. Exist. Concret SECTIO' ve Existing Wood Walls 3'- Remove Existing 14'-0" Wood Framed Roof t 12'i 0" . .... Extensions @ 4 O.G. s I " x 2" Nailer Attached to'k lk. Match Exist. Vented Soffit I — d.,n I 8f Oil I 81411 I I I Right Elevation Left Elevation t: ALTHOUGH GREAT CARE HAS BEEN TAKEN TO INSURE ACCURACY OF THESE CONSTRUCTION DRAWINGS, MISTAKES DO OCCUR. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO FIELD VERIFY ALL DIMENSIONS AND DETAILS BEFORE CONSTRUCTION COMMENCES 2: DUE TO SHRINKAGE AND EXPANSION OF PAN COPIES,WRITTEN DIMENSIONS TAKE PRECENDENCE OVER SCALING. 3: ENGINEERS CERTIFICATE OF THE CONSTRUCTION DRAWINGS ARE VIABLE FOR 6 MONTHS OR UNTIL GOVERNING AGENCY CODE CHANGES TAKE EFFECT. IF CODE CHANGES TAKE EFECT IT IS THE RESPONSIBILITY OF THE OWNER OR CONTRACTOR TO ENSURE THAT ALL CONSTRUCTION DRAWINGS ARE BROUGHT UP TO THE LATEST CODE SPECIFICATIONS BEFORE SUBMITTING FOR PERMIT. IF PLANS ARE SUBMITTED FOR PERMIT, BEFORE CHANGES HAVE BEEN MADE DUE TO CODE UPDATES, IT IS THE RESPONSIBILITY OF THE OWNER OR CONTRACTOR TO COMPENSATE THE DESIGNER AND ENGINEER FOR UPDATES,PRINTING AND CERTIFICATIONS. Iv Duio ltevisi"u . WjiSon x.407-02 2 Drawn: 466 Weathersfield Avenue Altamonte Springs, Florida 32714 rhwengr @ centurylink.net Design: Exist. Electric Panel Alum. Drip Rail --1" x 8" P.T. Facia Vented Alum. Soffit -Simpson H5 Rafter to Top Chord TI I I Wood Siding -Painted Typical Wall Section 12'-O" Remove/Relocate any siding and Electrical as needed. Existing Concrete Floor to .Remain to Remain Existing to remain \ Exist. 4" Step D W WH Exist. 8' S.G.D, Exist. 4" Step to Remain Breakfast/Dining Room Exist. Window \,-Exist. Blk. Wall to Remain .Kitchen EXISTING AND DEMO PLAIN :D GWW RIAW ME • Date: Scale: 0715?O11 Project: IJ� Rear Elevation Nimpson Simpson SP2 (tvt).) Simpson SP1 (typ.),/ i/z fvncnor icons � 1+6,. U.U.-S- Nlmpson Nei (typ.)_/ @ 32" O.C.'s @ 32" O.C.'s CYPICAL EXTERIOR LOAD BEARING WOOD WALL DETAIL n.t.s. PERMIT # Splice at verticle 1st t Chord F F I E Splice at 1st Top Chord 10d N (4) lOd Nails (2) Oeach side o1'splice !corn 2nd Top Chord (4) 10d nails (2).each side of splice Required 2x Dbl: Top Chord Splice Bctmcn Verticics a 1st Top Chord - (3) 10d Nails each side orjoint 2xi Splice Block 2x a 16" O.C.'s OFFICE PERM I yp. Wood Wall Splices o NFORD DI_I,IED A DEPT. ..,A 11. s. NS ARE REVIEYrED AND CONUrrIUi1AL!_Y THE- =FIT ac SHALL UE TO R I LICENSE TO PFiooEED WITI-1 ACCE:PTEU FUR PERMIT. A PERMIT I��UED VIOLATE, CONSTRJED AUTHORITY -ro THE TFlE WOkY. ANU NUT A ASID= ANY OF C ANGE r_. ALTER, O1� SET NOR SHALL A Rfvlrl PREVENT THE EC;O"DR G- PRUVL,IOI 15 OF'I"HE. TE' F" 11GAL• GODc ISSUAr7cE OF ITER c7 c_Qt.JIRING A CORFt C DEPT FROM THER "� THE F L-AI`7S, GUf I`�TFZUGTION EhROR OR OTHER VVOLATI..rJS FRAMING NOTES: 1. All wood framing shall be fabricated and Installed per AITC and TPI and National Design Specifications. ['or Wood Construction. 2. All Structural Wood iviembers shall have a Minimum extreme fiber stress bearing (FB) of 1,200 psi. 3. Unless otherwise noted, the following lurriber grades shall be. used: a. Structural Light Framing Size to be 2" thick x 4" wide No. 2 or better. b. Stud Size to be 2" thick x 4" wide or T thick x. 6" wide Stud Grade. c. Structural Joists and Planking to be 2" to 4" thick x 8" wide or wider No. 2 or better. d. Light Framing to be 2" thick x 4" wide or wider No. 2 or better. 4. Plywood sheathing shall be APA structural 1 - Group I ; size and span rating as shown on the construction drawings. 5. All wood members exposed to weather or in contact with rnasonary concrete or soils shall be Pressure 'Created. 6. Contractor shall provide all fastener devices as required by the Pre-Engr. BLISS Package. Fastening Devices subject to moisture shall be hot dipped galvanized to ASTM -153-80. 7. All metal connections and fabrications shall comply with AISC Speoitications. 8. Solid Block all Joists and Rafters at points of support. _ 9. Prefabricated Structural 'Trusses shall connply with NFPA National Design Specifications for Wood Construction and TPI Design Specitications for Metal Plate connected Wood Trusses and AITC 100. 10. All Trusses shall be designed and certified by the 'Truss Manufacturers Lisa: Engineer I and all Floor Joists sliall be Designed and Certified by the stung Engineer. 1 L Contractor s correlate with Truss/Floor Joist manufacturer to ensure adequate bearings are provided at end reactions ofall Girder Trusses. 12. Roof Trusses to be typictilly 2�1" U.C,'s unless othertivise noted in Pre -Engineered Truss Package. 8'-0" 13, Floor Joists to be,typically 16" O.C.'s unless otherwise noted on Pre -Engineered' Truss Package. ALTHOUGH GREAT CARE HAS BEEN TAKEN TO INSURE ACCURACY, MISTAKES CAN OCCUR, IT IS THE BUILDER'S RESPONSIBILITY TO VERIFY ALL DIMENSIONS AND DETAILS AND REPORT ANY DISCREPANCIES TO R,H, Wilson BEFORE BEGINNING CONSTRUCTION. '.Title of Page: Alteration :Level 2 signature: WINDSPEED -110 MPH /3 Sec. Gust WIND IMPORTANCE FACTOR = 1.0 WIND EXPOSURE CATAGORY ='B" EXT. COMPONANT AND CLADDING = + 12.5 TO - 19.9 PSF WINDOW .PRESSURE _ + 23.6 TO - 25.1 PSF IN'T'ERIOR PRESSURE = + 25.9 'I'0 - 28.1 PSF All Mechanical is to conforin to the 2007 Florida Building Code All Plumbing is to Conform to the 2007 Florida Buit(ling Code All Electrical is to conform to the 2008 National Electrical Code w/ Amendments. This Certifies that these plans tneet or exceed the 110 tnph/3 sec. gust of the 2007 Florida Building Code w/2009 Amendments Ronald H. Wilson, P.E. Lisc. No. 9710-� JUL 16 2011 ta, SLP 0 6 2011