206 S Scott Ave 10-1430 (A) ADDITIONv,. CONNECTOR SCHEDULE MODEL # FASTENERS UPLIFT(133) CAPACITY SP -1 6-10d 4-10d 585 SP -2 6-10d 6-10d 890 SP -4 6-10dxl 735 MTS12 14-10dx1 1000 MTS20 14-10dx1 1000 LSTA12 10-10d 755 LSTA24 18-10d 1295 LSTA30 22-10d 1670 LSTA36 26-10d 1715 _LSTA36 26-10d 1715 MSTA36 26-10d 1995 H TA1 11-1 x1 1 ply truss) 4-2" 114-16� 6-16d 1550 _H1IS26 H(',1A96-9 20-16d 8-16d 9000 1116 1816ci+id holt 3480 _H 24' O.C. (TYP.) _ARLJ44 19-16d jr] holt 99on ARLJ66 112_16cj+j� bolt 2,500 _ARU88 1F3-16d+2-jd bolts 9390 H - x1N 8-8dx1N H2.5 5-8d 5-8d 415 H 4-4-8d 455 HT -1 x11450 A35 12-18clxl� 385.1555 3655 .MGT22-10d T- 14-16d sinkers7 H T-2 8-10d+rd bolt4 HGT-3 8-10d+ bolt 90 MBHA H=7 18-10d + 1 ATR X8 TOP 1885 & 1 ATR X4 FACE C❑NNECTI❑N (TYP,) ATR is all threaded rod ASPH. SHINGLES TO MATCH EXISTING 12- 4 SIMPSON H 2.5 0 EA. RAFTER DBL. 2x HEADERS IJL 2x8 ROOF RAFTER 1/2" PLYWOOD WITH 15LB FELT ON TOP 30 IN UL 0 2x4 CEILING JOIST 16" O.C. P.T. 1x4 CUT @ 45° AROI PLANTER (TYP.) c ALUM. WINDOWS � 1/2" DRYWALL 20 STUDS 16° O.C. 2x4 PLATE CONT. Al R9 INSULATION 3/4" PLYWOOD 1/2' CEMENT BOARD DURAROCK) OVER 3/4" PLYWOOD SIMPSONt1ETA202x 8 FLOOR JOIST 16" O.C. 6" LAP SIDING �T OVER 15L6 FELT GALV. METAL TERMITE PLATE 8" x16" FILLED CONC. BLOCK CONC. BRICKS BETWEEN FOOTER AND FLOOR JOIST (SAME AS EXIST. FOUNDATION SYSTEM) GRA NOTE: DETAIL DEPUPICATES EXISTING " PIER AND SUB FLOOR CONFIGURATIONN ENTIRE EXISTING FLOOR SYSTEM CONSTRUCTED AS DETAIL — =1 I I-111J11-III=11HF, 1-1-Jjl-Jll 111=_1ll=111 WITH (2) #5 REBAR ANOTE: PROPOSED. FLOOR HTG. 16" ox,s W FOOTER CONT. WITH (2)„�S REBAR REMAINS THE SAME AS EXISTING. ALL DAMAGED ,s° DAVw FOOTER CONT. WOOD SHALL BE REPLACED. FULL HTG. WALL SECTION A -A W/PIER PROPOSAL DETAIL N.T.S. I i�r- 1A0-0# rt n_1 rrnMM❑N) OR 148X3 1/4' (16d SINKER) NAIL Simpson Strong -1 ie HUS210 2x6 P.T. (TYP.) ALTHOUGH GREAT CARE HAS BEEN TAKEN TO INSURE ACCURACY, MISTAKES CAN OCCUR, IT IS THE BUILDER'S RESPONSIBILITY TO VERIFY ALL DIMENSIONS AND DETAILS AND REPORT ANY DISCREPANCIES TO DDB SWEET, INC. BEFORE BEGINNING CONSTRUCTION, DECK REVISION PLAN GALV. S-ZLVS t' CC. 1/4'=1'-0' IN.. -- _ - -: BEAM STING FRAMED WALL I 6'-11” LOAD BEARNING I 2x4 16" 0.c. 8'7" max span i I (SEE CHART BELOW) i I I PROPOSE 2x6 KNEEW ;L.L (SEE PAGE 4 DETAIL) 10'2 PROPOSED ROOT - I PROPOSED 2x8 ROOF RAFTER �AlI �/11 6'9 I 16 O.C. TYP. LAW §21 T-=Ll-� IT rrrl I ! I I_Lo_E�, ! T `' N I PROPOSED 2x6 KNEEWALL (SEE PAGE 44 DETAIL) I i I I I i4 1- - - I I i — ---------- —J 14' PROPOSED ROOP' CEN1ZR 5' 2 19' PROPOSED STI'. ' ,ASTER BE =- ROOF FRAMING PLAN I 0 EXISTING STRUCTURE / '•1h S❑N HUS210 v _ .".1ECTI❑N (TY ��. Q0 PT. 2X10 BEA1,1 SIMPSON HUS210 @ EA CONNECTION (TYP.) 21'-3" EXISTING SCREENROOM EXISTING STRUCTURE REVISION C) ,� l B_ F I E WINDSPEED = 120 MPH WIND IMPORTANCE FACTOR = 1.0 WIND EXPOSURE CATAG❑RY =.//B# EXT. C❑MP❑NANT AND CLADDING = + 12.5 T — 19.9 PSF WIND❑W PRESSURE _ + 23.6 TO — 25.1 PSF INTERI❑R PRESSURE _ + 25.9 TO — 28.1 PSF NOTE:IT IS THE RESPONSIBILITY OF THE BUILDING CONTRACTOR TO REVIEW TRUSS ENGINEERING PACKAGE AGAINST FLOOR PLAN AND ELEVATIONS AND REPORT ANY DISCREPANCIES TO DESIGNER AND ENGINEER OF RECORD. „ , CONSTRUCT NEW FOOTER AND STEM WALL EXISTING P, 1. 2x1O BEAM ��L " r a EXISTING SIMPS❑N HUS2 0 @ EA. „ C❑NNECTI❑N (TYP,) } 114- SIMPSON HUS210 @ EA. I CONNECTION (TYP.) EXISTING STRUCTURE EXISTING P,T. 2x10 BEAM (f YP:; 4-2" P,T, 2x10 J❑IST f` i 24' O.C. (TYP.) 8'xl6' FILLED CIONC, BLOCKS P,T, 2x10 BEAM P,T. 2x10 BEAM I I w 00 I DIKI i SIMPS❑N HUS210 @ EA. C❑NNECTI❑N (TYP,) �— P T, 2x10 BEAM \— P,T, 6x6 POST W/3!4" I \-- s P.T. 4x4 POST IW/3/4" P.T, 6x6 POST W/3/4" GALV GALV, BOL , BOLT THRU GALV, BOLT '. THRU GALV, BOLT T RU AND NUT W/WASHER AND NUT W/WASHER AN NUT NUT TYP. TYP. ON CENTERLINE' OF DECK TYP. DECK SUB FLOOR AND BATH. FOUNDATION PLAN CONNECTION (TYP.) FLOOR F, AVING PLAN I 1/4'=1'-0' ROOF LIVE LOAD = 20PSF 1/4"=1'-0' i 21\ PLUMBING SIZE NOTES: CONVENTIONAL FRAMING SPANS ALL MA'\ DRAIN LINES TO BE A MINIMUM OF 3" EXITING THE HOUSE. SHOULD THERE BE MAX SPAN 24 O.C. MORE THAN 2 WATER CLOSETS THE MAIN LINE WILL EXIT 4". A STANDARD GUEST BATH RAFTER SPANS CEILING JOISTS FLOOR „v'STS CONSISTING OF (1) WATER CLOSET, (1) LAV, (1) TUB/OR SHOWER WILL HAVE iA MINIMUM 2x6 12"o.c. 14'9" max span 4 1 "o.c. 9'3" max span 202 12'a -L_ 23'4" max span VENT SIZE 0= 2" THRU ROOF. EACH HOUSE WILL HAVE (1) 3" MAIN VENT THRU ROOF. 2x6 16"o.c. 13'5" max span 2x4 16"0. 8'7" max span 2x12 tE'a 20'2" max span A WASHER STANDING ALONE WILL HAVE A MINIMUM OF 1 1/2" VENT THRU ROOF. 'IF THE 2x6 24"o.c. 1 1'9" max span 2x4 24"o.c. 7 max span 2x12 21.'o t. 16'6" max span I - WASHER IS STACKED WITH THE LAUNDRY TUB THE VENT THRU ROOF WILL BE 2„ . ALL 2x8 12"o.c. 19'6" max span 2x6 12"o.c. 14'9" max span 200 12c.c. 19'11” max span KITCHEN WILL BE AUTOVENT. 2" CLEAN OUTS WILL BE USED AT EXTERIOR WALL FOR 2x8 16"o.c. 17'9" max span 2x6 16"o.c. 12'11" max span 2x10 tE'c c_ 17'3" max span ACCESS. IN NO CASE WILL THERE EVER BE MORE THAN 3 MINOR AND (1) WATER CLOSET 2x8 24"o.c. 13'2" max span 2x6 24"o.c. 10'6" max span 2x10 24'c c_ ta•t" max span VENTED ON LESS THAN A 2" VENT. A WASHER WILL NEVER DRAIN PAST ANOTHER TUB/OR 2x10 12"o.c. 24'10" max span 2xs 12"o.c. 19'2" max span SHOWER USING THE SAME UPSTREAM VENT, AS WELL AS A WATER CLOSET WILL NEVER 2x10 16"o.c. 22'1" max span 2x8 16"o.c. 16'7" max span DRAIN PAST A TUB/OR SHOWER USING SAME UPSTREAM VENT. BATH VENTS TO TERMINATE 200 24"o.c. 18'1" max span 2x8 24"o.c. 13'7" max span THROUGH? ROOF VENTS OR SOFFIT 3' MIN. FROM WINDOW AND DOOR OPENINGS. 2x12 12"o.c. 26'0" max span 2x10 12'o.c. 22'9" max span 202 16"o.c. 26'0" max span 2x10 16"o.c. 19'9" max span 2x12 24"o.c. 21'4' max span 2x10 24'o.c. 16'1" max span NOTE: ALL SPANS BASED ON #2 SOUTHERN YELLOW PINE DESIGN LOADS Or 2:: PSF-LIVE LOADS _ 1r PSF-DEAD LOAD ARTHUR WILLIAM HULL, P.E. REVISION AND DATE DELAND , FL. 32724 l D REVISIONS PER CITY OF SANFORD-10130109 NOTES REVISED, NAILING SCHEDULE,ATTIC NOTE & REBAR PH# 407-497-0566 _ # REVISIONS PER CITY OF SANFORD-01-26-10 NOTES REVISED, STRAP REV. ON HEADER FL CERT. 33672 t I i 1/4'=1'-0' P.T. 2X6 DECORATIVE BEAMS 24" O.C. TYP, SOU I H. E1_F VATION 1/4'=1'-0' MANM BATH ADD. PLAN Email: ddbsweet@earthlink.net SHEET,'inc "We.�ring Visions To Life" phone: (407)221-5168 PLAN FOR: RUSSELL & ANITA MANN _C ADDR� ESS: Zos S. SCOTT AVE. S NFORD , FLA. 32771 DATE: sloe SCALE: PAGE: PROP.,, I.D.# 30-19-31-502-0200-0040 30F5 2 X 4 FIRE - BLOCKING AT MID -SPA[ _ I SIMPSON MTT28B H5 EVERY STUD TDP / ROOF FRAMING \ DOUBLE TDP PLATE ��I��ll�istsimmlw L -HS EVERY STUD @ BOTT PL � CLIPS REQ'D WHEN SILL PL. EXCEEDS 48" H, GENERAL NOTES .1___- ,___-1.1 FLORIDA RESIDENTIAL BUILDING CODE (2007) ED. WITH 2009 REVISIONS. I . I DETAIL 1.2 BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE (ACI 318-95). CORNERS 1.3 AMERICAN SOCIETY OF CIVIL ENGINEERS MINIMUM DESIGN LOADS FOR MAXIMUM SPAN v V STRAPS EACH END OF HEADER 2) CONCRETE: 5•-1" 2.1 CONCRETE COMPRESSIVE STRENGTH AT 28 DAYS: 1 2.1.1 PRE -CAST W/STANDARD REINFORCEMENT - 3500 PSI 6 -0 2.1.2. PRE -CAST W/PRESTRESS REINFORCEMENT - 5000 PSI 1 2.1.3. CONCRETE FILL (PLACED IN FIELD) - 2500 PSI 8 -2-1 2.2 REINFORCING BARS: SP2 2.2.1. STEEL PLACED IN PRECAST LINTEL AT TIME OF FABRICATION ASTM A615 (GRADE 60). 2.2.2. STEEL IN LINTEL AND KNOCKOUT BLOCK (PLACED IN FIELD) ASTM A615 (GRADE 40). 2.3 PRESTRESS STRANDS ASTM A416 7 -WIRE 2.4 DETAIL REINFORCEMENT IN ACCORDANCE WITH ACI 315. 2.5 CONCRETING OPERATIONS SHALL COMPLY WITH ACI STANDARDS. 3) MASONRY: FULL LENGTH WALL STUDS- TUDHEADER SP2 ca1 3.1 DESIGN AND CONSTRUCTION SHALL CONFORM TO THE SPECIFICATION OF THE NATIONAL CONCRETE MASONRY ASSOCIATION AND ACI 530. 3.2 MINIMUM MASONRY UNIT STRENGTH: Vm 1250 PSI. 3.3 MORTAR SHALL BE TYPE S OR M. � 4) STRUCTURAL: 4.1 SAFE LOAD VALUES ARE BASED ON LINTELS HAVING A BEARING OF 8" (WITH A MINIMUM ACCEPTABLE BEARING OF 4" PER THE 2007 EDITION OF THE FLORIDA RESIDENTIAL BUILDING CODE WITH 2009 REVISIONS) HEADER SIMPS❑N LSTA9 AT EVERY CRIPPLE BATT, SIMPS❑N LS A18 HEADERSTUDS H5 TYP, ��I��ll�istsimmlw L -HS EVERY STUD @ BOTT PL � CLIPS REQ'D WHEN SILL PL. EXCEEDS 48" H, GENERAL NOTES .1___- ,___-1.1 FLORIDA RESIDENTIAL BUILDING CODE (2007) ED. WITH 2009 REVISIONS. I . I DETAIL 1.2 BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE (ACI 318-95). CORNERS 1.3 AMERICAN SOCIETY OF CIVIL ENGINEERS MINIMUM DESIGN LOADS FOR MAXIMUM SPAN BUILDINGS AND OTHER STRUCTURES (ASCE 7-95). STRAPS EACH END OF HEADER 2) CONCRETE: 5•-1" 2.1 CONCRETE COMPRESSIVE STRENGTH AT 28 DAYS: 1 2.1.1 PRE -CAST W/STANDARD REINFORCEMENT - 3500 PSI 6 -0 2.1.2. PRE -CAST W/PRESTRESS REINFORCEMENT - 5000 PSI 1 2.1.3. CONCRETE FILL (PLACED IN FIELD) - 2500 PSI 8 -2-1 2.2 REINFORCING BARS: 1 2 2.2.1. STEEL PLACED IN PRECAST LINTEL AT TIME OF FABRICATION ASTM A615 (GRADE 60). 2.2.2. STEEL IN LINTEL AND KNOCKOUT BLOCK (PLACED IN FIELD) ASTM A615 (GRADE 40). 2.3 PRESTRESS STRANDS ASTM A416 7 -WIRE 2.4 DETAIL REINFORCEMENT IN ACCORDANCE WITH ACI 315. 2.5 CONCRETING OPERATIONS SHALL COMPLY WITH ACI STANDARDS. 3) MASONRY: 3.1 DESIGN AND CONSTRUCTION SHALL CONFORM TO THE SPECIFICATION OF THE NATIONAL CONCRETE MASONRY ASSOCIATION AND ACI 530. 3.2 MINIMUM MASONRY UNIT STRENGTH: Vm 1250 PSI. 3.3 MORTAR SHALL BE TYPE S OR M. 4) STRUCTURAL: 4.1 SAFE LOAD VALUES ARE BASED ON LINTELS HAVING A BEARING OF 8" (WITH A MINIMUM ACCEPTABLE BEARING OF 4" PER THE 2007 EDITION OF THE FLORIDA RESIDENTIAL BUILDING CODE WITH 2009 REVISIONS) 2 X 4 FIRE BLOCKING AT MID -SPAN /2" X 8" A B. 48" O/C TYPICAL FRAMING AND CONNECTIONS FOR OPENINGS OR RSP4 FULL LENGTH WALL STUDS 10d NAILS 0 12"O.C. BOTH SIDES STAGGERED 2 ROWS H5 .SP4 OR RSP4 ALTHOUGH GREAT CARE HAS BEEN TAKEN TO INSURE ACCURACY, MISTAKES CAN OCCUR. IT IS THE BUILDER'S RESPONSIBILITY TO VERIFY ALL DIMENSIONS AND DETAILS AND REPORT ANY DISCREPANCIES TO DDB SWEET, INC. BEFORE BEGINNING CONSTRUCTION, GENERAL_ NOTES: 1. CONTRACTOR IS TO ASCERTAIN THAT ALL CONSTRUCTION SHALL BE IN COMPLIANCE WITH ALL APPLICABLE BUILDING CODES AND LOCAL RESTRICTIONS AND THAT THE CONSTRUCTION DOCUMENTS ARE IN ACCORDANCE WITH APPLICABLE LAWS, STATUES, ORDINANCES, CODES, RULES, AND REGULATIONS. IF THE CONTRACTOR OBSERVES THAT PORTIONS OF THE CONSTRUCTION DOCUMNETS ARE AT VARIANCE THEREWITH, THE CONTRACTOR SHALL PROPMPTLY NOTIFY THE DESIGNER IN WRITING AND THE NECESARY CHANGES SHALL BE INITIATED AND ACCOMPLISHED BY APPROPRIATE MODIFICATION. 2. DIMESIONS TAKE PRECEDENCE OVER DRAWINGS. DO NOT SCALE DRAWINGS TO DETERMINE ANY LOCATIONS. IF ANY DISCREPANCIES OCCUR, NOTIFY THE DESIGNER AT ONCE FOR CLARIFICATION. 3. ALL WOOD IN CONTACT WITH MASONRY, CONCRETE OR STEEL SHALL BE PRESSURE TREATED. 4. ALL PRODUCTS AMD MATERIALS SHALL BE APPLIED AND/OR INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S PUBLISHED SPECIFICATIONS. 5. CONTRACTOR SHALL VERIFY ALL WINDOW AND DOOR MASONRY OPENINGS WITH MANUFACTURER PRIOR TO COMMENCEMENT OF CONSTRUCTION. 6. ALL PLAN DIMENSIONS ARE FROM FACE OF BLOCK OR FACE STUD AND ARE NOMINAL UNLESS OTHERWISE INDICATED. 7. HVAC SYSTEM DESIGN BY OTHERS. LAYOUT IS DIAGRAMATIC. 8. THIS STRUCTURE HAS BEEN DESIGNED TO MEET OR EXCEED THE 120 MPH WIND LOAD REQUIREMENTS OF THE FLORIDA RESIDENTIAL BUILDING CODE, 2007 EDITION WITH 2009 REVISIONS. 9. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL WATER PROOFING. , An PLAN DETAIL @ REIN F LAP SPLICE @ CONT FTG CORNERS BARS W/ 30" LAP CORNER BARS SHALL BE SAME SIZE & QTY AS FTG REINF PLAN DETAIL LOAD BEARING WALLS HEADER/STUD/STRAP CHART (NTS) CORNERS 2 SYP EADER SIZE MAXIMUM SPAN VADER STUDS FULL L�I�GTH fr EACH END STUD S) O EA H END STRAPS EACH END OF HEADER 2)2X6 5•-1" 1 1 1 (2)2X8 6 -0 1 1 1 (2)2X10 8 -2-1 2 1 2 1 2 2 2X12 1 g'-8- 2 1 2 1 2 ALTHOUGH GREAT CARE HAS BEEN TAKEN TO INSURE ACCURACY, MISTAKES CAN OCCUR. IT IS THE BUILDER'S RESPONSIBILITY TO VERIFY ALL DIMENSIONS AND DETAILS AND REPORT ANY DISCREPANCIES TO DDB SWEET, INC. BEFORE BEGINNING CONSTRUCTION, GENERAL_ NOTES: 1. CONTRACTOR IS TO ASCERTAIN THAT ALL CONSTRUCTION SHALL BE IN COMPLIANCE WITH ALL APPLICABLE BUILDING CODES AND LOCAL RESTRICTIONS AND THAT THE CONSTRUCTION DOCUMENTS ARE IN ACCORDANCE WITH APPLICABLE LAWS, STATUES, ORDINANCES, CODES, RULES, AND REGULATIONS. IF THE CONTRACTOR OBSERVES THAT PORTIONS OF THE CONSTRUCTION DOCUMNETS ARE AT VARIANCE THEREWITH, THE CONTRACTOR SHALL PROPMPTLY NOTIFY THE DESIGNER IN WRITING AND THE NECESARY CHANGES SHALL BE INITIATED AND ACCOMPLISHED BY APPROPRIATE MODIFICATION. 2. DIMESIONS TAKE PRECEDENCE OVER DRAWINGS. DO NOT SCALE DRAWINGS TO DETERMINE ANY LOCATIONS. IF ANY DISCREPANCIES OCCUR, NOTIFY THE DESIGNER AT ONCE FOR CLARIFICATION. 3. ALL WOOD IN CONTACT WITH MASONRY, CONCRETE OR STEEL SHALL BE PRESSURE TREATED. 4. ALL PRODUCTS AMD MATERIALS SHALL BE APPLIED AND/OR INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S PUBLISHED SPECIFICATIONS. 5. CONTRACTOR SHALL VERIFY ALL WINDOW AND DOOR MASONRY OPENINGS WITH MANUFACTURER PRIOR TO COMMENCEMENT OF CONSTRUCTION. 6. ALL PLAN DIMENSIONS ARE FROM FACE OF BLOCK OR FACE STUD AND ARE NOMINAL UNLESS OTHERWISE INDICATED. 7. HVAC SYSTEM DESIGN BY OTHERS. LAYOUT IS DIAGRAMATIC. 8. THIS STRUCTURE HAS BEEN DESIGNED TO MEET OR EXCEED THE 120 MPH WIND LOAD REQUIREMENTS OF THE FLORIDA RESIDENTIAL BUILDING CODE, 2007 EDITION WITH 2009 REVISIONS. 9. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL WATER PROOFING. , An PLAN DETAIL @ REIN F LAP SPLICE @ CONT FTG CORNERS BARS W/ 30" LAP CORNER BARS SHALL BE SAME SIZE & QTY AS FTG REINF PLAN DETAIL @ CORNERS BAR LAP SPLICE @ CONT FTG i NOTES: 1. FOUNDAT ON DESIGN BASED ON 2000 P.S.F. MINIMUM ALLOWABLE BEARING PRESSURE. SUBMIT SOILS REPORT BY FLORIDA REGISTERED ENGINEERING FOR REVIEW PRIOR TO FOUNDATION POUR. 2. ALL CONCRETE WORK SHALL BE IN ACCORDANCE WITH A.C.I. 301-79 AND SHOP DRAWINGS WITH A.C.I. 315-80. SHOP DRAWINGS SHALL BE SUBMITTED TO ARCHITECT FOR APPROVAL PRIOR TO FABRICATION OR CONC. POUR. 3. CONCRETE 28 DAY STRENGTH; SLABS, FOOTING; 2500 P.S.I. 2/ 3/4" MAX. AGGREGATE. 4. REINFORCING STEEL; ASTM A615, GRADE 60 EXCEPT STIRRUPS AND TIES MAY BE GRADE 40. 5. STRUCTURAL DESIGN IS BASED ON AN ENCLOSED STRUCTURE. WINDOWS SHALL BE COVERED WITH STORM SHUTTERS OR PLYWOOD FOR HURRICANE CONDITIONS TO PREVENT PROJECT: E PENETRATION, 6. DESIGN L ADS: IN ACCORDANCE WITH F.B.C., 2007 RESIDENTIAL ED WITH 2009 REVISIONS. ROOF LIVE LOAD: 20 P.S.F. WIND LOADS: IN ACCORDANCE W/ F.B.C. 01 EDITION FOR 120 MPH REGION REFERENCING ASCE-7 INTERIOR PARTIONS: 5 P.S.F. PERPENDICULAR TO WALL FACE 7. PRE -EN INEERED WOOD TRUSSES SHALL BE DESIGNED IN ACCORDANCE W/ F.B.C. TRUSS MANUFACTURER SHALL SUBMIT SIGNED AND SEALED DRAWINGS FOR APPROVAL PRIOR TO FABRICATION. 8. LUMBER 3RADE SHALL BE: A, EADER, COLUMNS, BEAMS #2 S.Y.P. 0 RBUILT FRAMING FB -1500 PSI B. I fALLS, BLOCKING, MISC. #2 SPF C. ILL PLATES #S.Y.P. P.T. 9. ALL NAIL3 SHALL BE COMMON WIRE NAILS UNLESS NOTED OTHERWISE. 10, CHECK LL DIMENSIONS WITH FLOOR PLAN BEFORE POURING FOUNDATION EXCLUDED 11, THIS ST UCTURE DESIGN EXTENDS TO ITEMS COVERED BY SSTD 10-99 EXCLUDE ARE FINISHES, NON-STRUCTURAL ITEMS, MISC. PARTS OVERHEAD DOORS, OOFING, WALL WATERPROOFING WHICH ARE DESIGNED BY OTHERS. 12 CONCRE FLOOR SLAB IS EXPECTED TO DEVELOP SHRINKAGE CRACKS. 13. CONCRE E MASONRY: ASTM C-90, WITH 28 DAY PRISM STRENGTH OF 2000 P.S.I. MI . WITH TYPE M OR S MORTAR. MASONRY PRECAST LINTELS SHALL BE PROVIDED ABOVE ALL OPENINGS. ALL MASONRY WORK SHALL BE IN ACCORDANCE W/ A.C.I, 530 AND A.C,I. 531. PROVIDE MASONRY CLEANOUTS ALL FILLED CELL LOCATIONS. SUBMITTAL NOTES: 1. SPECIALTY ENGINEER FOR PRE-ENGINEERED WOOD TRUSSES SHALL BE A FLORIDA REGISTERED ENGINEER AND SIGNED AND SEALED HOP DRAWINGS INCLIDING CALCULATIONS SHALL BE SUBMITTED TO ARCHITECT FOR REVIEW AND APPROVA PRIOR TO FABRICATIO OR ERECTION. PRE-ENGINEERED WOOD TRUSSES SHALL BE DESIGNED IN COMFORMANC WITH 2007 F.B.C. RESIDENTIAL EDITION WITH 2009 REVISIONS. 2. SHOP DRAWINGS SHALL INCLUDE TEMPORARY BRACING FOR ERECTION AND HANDLING AND PERMANENT BRACING AS REQUIRED B SPECIALTY ENGINEER. TRUSS NOTES: 1. TRUSSES SHALL BE DE IGNED BY FLORIDA REGISTERED ENGINEER EXPERIENCED IN TRUSS DESIGN. PROVIDE SHOP DRAWINGS 0 ARCHITECT FOR APPROVAL PRIOR TO FABRICATION. SHOP DRAWINGS SHALL BEAR THE SEAL OF THE ENGINEER. 2. TRUSS FABRICATOR SHA.L PREPARE A "FRAMING LAY -OUT" INDICATING THE LOCATION OF TRUSSES, BEARINGS TRUSS SPACING, PITCH, BRACING LOCATION, AND OTHER INFORMATION DEEMED PERTINENT. ARCHITECT WILL PROVIDE TO FABRICATOR, UPON REQUEST, ONE REVERSE SEPIA FOR THIS USE. FABRICATOR SHALL SUBMIT "FRAMING UY-OUT" TO ARCHITECT FOR APPROVAL PRIOR TO FABRICATION. UPON APPROVAL, FABRICATOR SHALL PROVIDE' COPIES TO CONTRACTOR AND TRUSS ERECTOR FOR FIELD USE, 3. CONTRACTOR SHALL BE RESPONSIBLE FOR PROPER TRUSS HANDLING AND POPER TEMPORARY AND ERECTION BRACING. 4. PERMANENT BRACING AS INDICATED ON DRAWINGS SHALL BE MINIMUM 2X4 DIMENSION LUMBER WITH 2-16D NAILS IN NAILS IN EACH TRUSS, UNLESS INDICATED OTHERWISE. ADDITIONAL BRACING AS REQUIRED OR RECOMMENDED BY TRUSS DESIGNER OR FABRICATOR SHALL BE INCLUDED AND INSTALLED. 5.TRUSS FABRICATOR SHALI, BE RESPONSIBLE TO COORDINATE ALL TRUSS DIMENSIONS WITH FIELD CONDITIONS PRIOR TO FABRICATION. NOTIFY ARCHITECT IN WRITING IF ANY ADJUSTMENTS TO DRAWING DIMENSIONS ARE RECOMMENDED OR REQUIRED. 6. PROVIDE HURRICANE ANCHORS ANCHORS AS PER GOVERNING CODES AND REGULATION, AND AS INDICATED ON DRAWINGS. NAILING SCHEDULE ROOF & END GABLE: 8d RING SHANK NAILS AT 4" D.C. AT SUPPORTED PANEL EDGES OF 1/2" MIN. APA RATED CD!X PLYWOOD , W/8d NAILS AT 6" D.C. AT INTERIOR SU PORTS, I WALL SHEATHING: 8d NAILS AT 4" D.C. AT SUPPORTED PANEL EDGES OF 1/2" APA RATED �CDX PLYWOOD, W/8d NAILS AT 12" D.C. AT INTERIOR SUPPORTS, WINDSPEED = 120 MPH WIND IMPORTANCE FACTOR = 1.0 WIND EXPOSURE CATAGORY ='B' EXT. COMPONANT AND CLADDING = + 12.5 TO - 19.9 PSF WINDOW PRESSURE _ + 23.6 TO - 25.1 PSF INTERI❑R PRESSURE _ + 25.9 TO - 28.1 PSF NOTE:IT IS THE RESPONSIBILITY OF THE BUILDING CONTRACTOR TO REVIEW TRUSS ENGINEERING PACKAGE AGAINST FLOOR PLAN AND ELEVATIONS AND REPORT ANY DISCREPANCIES TO DESIGNER AND ENGINEER OF RECORD ARTHUR WILLIAM HULL, P.E. MANN BATH ADD. PLAN ? Email: ddbsweet@earthlink.net S!V ET, inc "We ring Visions To Life" Phone: (407)221-5168 PLAN FOR: RUSSELL & ANITA MANN ADD ESS: 206 S. SCOTT AVE. SANFORD,_FLA.32771 DA :6/09 SCALE:. PAGE: REVISION AND DATE ITEM DEWAIN D , FL. 32724 0 REVISIONS PER CITY OF SANFORD-10/30/09 NOTES REVISED, NAILING SCHEDULE,ATTIC NOTE & REBAR PH# 407-497-0566 FL CERT. # 33672 PROP. I.D.# 30-19-31-502-0200-0040 ® REVISIONS PER CITY OF SANFORD-01-26-10 NOTES REVISED, STRAP REV. ON HEADER i 40F5