Loading...
3908 Saltmarsh Lp- 18-1265; NEW SFHWP 3L THIS INSTRUMENT PREPARED BY: Name: Tania Pickering Address: 5200 Vineland Road Suite 200 Orlando, Florida 32811 NOTICEOF COMMENCEMENT Permit Number: 18-1265 Parcel ID Number: 17-29-31-592-0000-40 The undersigned hereby gives notice that Improvement will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement. 1. DESCRIPTION OF PROPERTY: (Legal description of the property and street address if available) Lot 34 Wyndham Preserve Plat Book 81 / Pages 93-102 3908 Saltmarsh Loop, Sanford FL 32773 2. GENERAL DESCRIPTION OF IMPROVEMENT: Construction of a new single family residence 3. OWNER INFORMATION OR LESSEE INFORMATION IF THE LESSEE CONTRACTED FOR THE IMPROVEMENT: Name and address: Park Square Ente!prises LLC 5200 Vineland Rd Suite 200 Orlando FL 32811 Interest in property: Fee Simple Fee Simple Title Holder (if other than owner listed above) Name: Address: 4. CONTRACTOR: Name: Park Square Homes Phone Number: 407-529-3000 Address: 5200 Vineland Road Suite 200 Orlando, Florida 32811 5. SURETY (If applicable, a copy of the payment bond is attached): Name: N/A Address: N/A Amount of Bond: N/A 6. LENDER: Name: Fifth Third Bank Phone Number: Address: 5050 Kingsley Dr. MD: 1 MOM Cincinnati, OH 45227 7. Persons within the State of Florida Designated by Owner upon whom notice or other documents may be served as provided by Section 713.13(1)(a)7., Florida Statutes. Name: Phone Number: Address: 8. In addition, Owner designates of to receive a copy of the Lienor's Notice as provided in Section 713.13(1 Xb), Florida Statutes. Phone number: 9. Expiration Date of Notice of Commencement (The expiration is 1 year from date of recording unless a different date is specified) WARMG TO QWb6M ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION, IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. Ahw Ajwq ffl,% Signature of Owner or Lessee, or Own if Lefim's Authorized Officer/Director/Partner7ger Vishaal Gupta, Executive Vice President Print Name and Provide Signatory's Tide/Office) State of County of aNWz-- Q The foregoing Instrument was acknowledged before me this day of by Who Is personally known to meter -'0R who has produced Identification 0 type of Identification produced: EXPIRES: June 27,2019 Don* To ewildt Notary Serrites Notary v CITY OF SANFORD BUILDING & FIRE PREVENTION PERMIT APPLICATION Application No: 4'_" / Documented Construction Value:$ V068" 7_A4qZ(c,2.c`0 Job Address: 3908 Saltmarsh Loop, Sanford 32771 (Wyndham Preserve lot 34) Historic District: Yes [I No F-1 Parcel ID: 17-20-31-502-0000-0340 Residential RX Commercial 11 Type of Work: New Z AdditionEl AlterationEl RepairEl DemoE] Change of UseE] MoveEl Description of Work: Construction of new single family residence Plan Review Contact Person: Michelle Parkison Phone: 407-529-3135 Fax: I OT =11" Street: City, State Zip: Title: Permitting Manager Email: mparkisgnft—parksguarghomes.corn Property Owner Information Phone: Resident of property? : No Contractor Information Name Park Square Homes/ Vishaal Gupta Street: 5200 Vineland Rd Suite 200 City, State Zip: Orlando, FL 32811 Phone: 407-529-3000 Fax: 407-529-3001 State License No.: CRC1330351 Arch. / MJS Home Designs Arch itect/E ngi neer Information Name: Eng. / Don Bolden Eng. Phone: Arch./ 250 N. \Atymore Rd. Suite B Winter Park FL 32789 Street: Encl./ PQ Box 530783, Debsity FL 32753 - Fax: City, St, Zip: Bonding Company: Address: E- mail: Arch. 407- 629-6711 Enq. 386-668-7606 Mortgage Lender: Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: 5' Edition (2014) Florida Building Code Revised. June 30, 2015 Permit Application NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal. The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value, credit will be applied to your permit fees when the permit is issued, OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Signature of Own 'gent Date Vishaal Gupta Print OwnerUN9"` - S Name ig atu x of Notary -fate of Florida Date MICHELLE PARKISON Notary Public - State of Florida Commission GG 157861 My CommExpires Nov 5, 2021lbomleoitIilionolNotaryOwner/ Agor Produced ID Type of ID Signature itractor/ Agent Date Vishaal Gupta Print Contractor/ Agent's Nanic 4 Xurof Notary - State of Florida— Date— f,%, MICHELLE P: ARKDISON Notary Public - State of Florida Commission # GG 167861 My Comm FgPires Nov 5, 2021 vrc borld"d through Nottrusiti Notary Aititi al Notary Contractor/Agent Produced ID Type of ID BELOW IS FOR OFFICE USE ONLY Permits Required: BuildingRr Electrical[K Mechanicalr'_," Plumbing® Gas[] Roof I \I LiConstructionType: V (?> . Occupancy Use: Flood Zone: Total Sq Ft of Bldg: Z_Zl Min. Occupancy Load: Z- # of Stories:, Z New Construction: Electric - # of Amps 7, LY0 Plumbing - # of Fixtures Fire Sprinkler Permit: Yes F-1 No #of Heads I APPROVALS: ZONING: i j>j I Ili UTILITIES: ENGINEERING: A-VO'$ FIRE: COMMENTS: — Ok to construct single family home with setbacks and impervious area shown can plan. 1_7SO Sun8aLyice- - A, 6rL- 9 krT-4c, 1^ 30, Fire Alarm Permit: Yes[] No WASTE WATER: BUILDING: liF 5-( 1-% Revised .tune 30, 2015 Permit Application CITY OF SANFORD i tE i, BUILDING & FIRE PREVENTION l « PERMIT APPLICATION Application No: Documented Construction Value: $ 150,537.00 Job Address: 3908 Saltmarsh Loop, Sanford 32771 (Wyndham Preserve lot 34) Historic District: Yes No Parcel ID: 17-20-31-502-0000-0340 Residential® Commercial Q Type of Work: New 0 Addition Alteration Repair Demo Change of Use Move Description of work: Construction of new single family residence Plan Review Contact Person: Michelle Parkison Title: Permitting Manager Phone:407-529-3135 Fax: Name Street: City, State Zip: Email: LnpariaonQparkaqugrehgmes.con1 Property Owner Information Phone: Resident of property? : Contractor Information Name Park Square Homes/ Vishaal Gupta Street: 5200 Vineland Rd Suite 200 City, State Zip: Orlando, FL 32811 0 Phone: 407-529-3000 Fax: 407-529-3001 State License No.: CRC1330351 Arch. / MJS Home Designs Arch itecVEngineer Information Arch. 407-629-6711 Name: Eng. / Don Bolden Eng. Phone: Eng. 386-668-7606 Arch./ 250 N. Wymore Rd. Suite B Winter Park FL 32789 Street: Eng./ PQ Bgx Q07FL327 Fax: City, St, Zip: Bonding Company: Address: E- mail: Mortgage Lender: Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. FBC 105. 3 Shall be inscribed with the date of application and the code in effect as of that date: 5" Edition (2014) Florida Building Code Revised: June 30, 2015 Permit Application NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or'federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal. The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value, credit will be applied to your permit fees when the permit is issued. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Z-a- la Signature of Own gent Date Vishaal Gupta Print Owner/ Agenl's Name S igdaiu'totNotary- --ZteofFlorida Date MICHELLE PARKISON State 10 NotaryPublic - State of Florida r Commission # GG 157861] as NovMy Comm, Expires ov 5, 2021 Owner/ Ag 'Aonqud or Produced ID Type of ID a> . 8 Signature of Contractor/Agent Date Vishaal Gupta — Print Contractor/Agpnif's Name Wig t—u, of Notary -State of Florida— 0 Date T TMICHELLE PARIKISON Notary Public - State of Florida] Commission # 00 167861 Nov 021 M.61,1 My Comm. Expires Nov 5, 2021 8ftod through ftlunw Notary Assn, Contractor, it is 11 - RM: Produced ID _ Type of ID BELOW IS FOR OFFICE USE ONLY Permits Required: Building [] Electrical [] Mechanical [] PlumbingF] Gas[] Roof n Construction Type: Occupancy Use: Total Sq Ft of Bldg: Min. Occupancy Load: New Construction: Electric - # of Amps Fire Sprinkler Permit: Yes Fj No 7 #of Heads APPROVALS: ZONING: ENGINEERING: COMMENTS: Flood Zone: of Stories: Plumbing - # of Fixtures Fire Alarm Permit: Yes R No R UTILITIES: IZI-15WASTEWATER: FIRE: - BUILDING: Revised: June 30,2015 Permit Application REQUIRED INSPECTION SEQUENCE PARK SQUARE HOMES SFR-DETACHED Permit # BUILDING PERMIT Min Max Ins ection Description 10 Form board / Foundation Survey 10 Slab / Mono Slab Prepour 20 Lintel / Tie Beam / Fill / Down Cell 30 Sheathing — Walls 30 Sheathing —Roof 40 Roof Dry In 50 Frame 60 Insulation Rough In 70 Drywall / Sheetrock 40 70 Lath Inspection 50 1000 Final Roof 50 1000 Final Stucco / Siding 80 1000 Insulation Final 1000 Final Single Family Residence AAA race CTRICAL PERMIT Min Max inspection Description 10 Underground Electric 10 Footer / Slab Steel Bond 20 30 Temporary Underground Power (TUG) 30 Electric Rough 1000 Electric Final t fi r _ s Min Max Inspection Description 10 Plumbing Underground 20 Plumbing Tubset 10 1000 Plumbing Sewer 1000 Plumbing Final MEcx.vrcaL PERMIT Min Max Inspection Description 10 Mechanical Rough 1000 Mechanical Final REVISED: June 2014 City of Sanford Planning and Development Services Engineering — Floodplain Management Flood Zone Determination Request Form Name: Michelle Parkison Firm: Park Square Homes Address: 5200 Vineland Road, Suite 200 City: Orlando State: FL Zip Code: 32811 Phone: 407-529-3135 Fax: Email: mparkisonCa)parksquarehomes.com Property Address: 3908 Saltmarsh Loop Property Owner: Park Square Enterprises, LLC Parcel identification Number: 17-20-31-502-0000-0340 Phone Number: 407-529-3000 Email: The reason for the flood plain determination is: W New structure Existing Structure (pre-2007 FIRM adoption) Expansion/Addition Existing Structure (post 2007 FIRM adoption) Pre 2007 FIRM adoption = finished floor elevation 12" above BFE Post 2007 FIRM adoption = finished floor elevation 24" above BFE (Ordinance 4360) nm- NOW W6 IV021,11 M W" A Flood Zone: X Base Flood Elevation: N/A Datum: N/A FIRM Panel Number- 120294 0090 F Map Date: Sept. 28, 2007 The referenced Flood Insurance Rate Map indicates the following: The parcel is in the: floodplain floodway A portion of the parcel is in the: floodplain floodway W The parcel is not in the: *Wfloodplain E]floodway The structure is in the: F-1floodplain E]floodway The structure is not in the: floodplain 0 floodway If the subject property is determined to be flood zone 'A', the best available information used to determine the base flood elevation is: BP# 18-1265 Reviewed by: Michael Cash, CFM Date: March 27, 2018 i I o I Application far Paved Driveway, Sidewalk or w*_ 1 Landscaping Walkway Including Right -of -Way Use & N _1877— in 0;tjk+ —WfIN cay www.sanfordfl.gov Department of Planning & Development Services 300 North Park Avenue, Sanford, Florida 32771 Phone: 407.688,5140 Fax: 407.688.5141 This permit authorizes work to be done on the subject property or in the City of Sanford's right-of-way in accordance with the City's regulations and the attached construction plans approved as part of this permit. The permit is required for driveway or sidewalk construction over 100 square feet of concrete or other material on the subject parcel and I or any construction of a driveway, walkway or landscape improvements within the city right-of-way. It does not approve any work within any other jurisdiction's right-of-way. All requested information below as well as a current survey, site plan or plat clearly identifying the Know. whors below. size and location of the existing right—of-way and use shall be provided or application could be delayed. Call before you d1% 1. Project Location/Address: 2. Proposed Activity: Z Driveway D Walkway Other: 3. Schedule of Work: Start Date Completion Date El Emergency Repairs 4. Brief Description of Work: Construction of new driveway for new single family residence This application is submitted by: Property Owner J 'I Signature: 10o'll ::f Address: 5200 Vineland Rd Suite 200 Orlando, FL 32811 Phone: (407) 529-3135 Fax: Print Name: Vishaal Gupta Email: rnparkison@parksquarehomes com Date: -3.8-1a Maintenance Responsibilitiestindemnification The Requester, and his successors and assigns, shall be responsible for perpetual maintenance of the improvement installed under this Agreement. This shall include maintenance of the improvement and unpaved portion of right-of-way adjacent thereto. Requestor may, with written City authorization, remove said installation/improvement fully restoring the right-of-way to its previous condition. In the event that any future construction of roadways, utilities, stormwater facilities, or any general maintenance activities by the City becomes in conflict with the above permitted activity, the permittee shall remove, relocate and/or repair as necessary at no cost to the City of Sanford insofar as such facilities are in the public right-of-way. If the Requestor does not continuously maintain the improvement and area in accordance with previously stated criteria, or completely restore the right-of-way to its previous condition, the City shall, after appropriate notice. restore the area to its previous condition at the Requestor's expense and, if necessary, file a lien an the Requestor's properly to recover costs of restoration. To the fullest extent permitted by law, Requestor agrees to defend, indemnify, and hold harmless the City, its councilpersons. agents, servants, or employ- ees (appointed, elected, or hired) from and against any and all liabilities. claims penalties, demands, suits, judgments, losses, expenses, damages (direct, indirect or consequential), or injury of any nature whatsoever to person or property, and the costs and expenses incident thereto (including costs of defense, settlement, and reasonable attorney's fees up to and including an appeal), resulting in any fashion from or arising directly or indirectly out of or connected with the use of the City's right-of-way. I have read and understand the above statement and by signing this application I agree to its terms. Signature: Date: This permit shall be posted on the site during construction. Please call 407.688.5080 24 hours in advance to schedule a pre -pour inspection. Pre -pour Inspection by: Date: Application No: Reviewed: Public Works Utilities Approved: Engineering Site Inspected by: Special Permit Conditions: Official Use Only Fee: Date: Date: Date: Date: k co Date: November 2D15 HUVV USe UnVeWay PCP LIMITED POWER OF ATTORNEY Altamonte Springs, Casselberry, Lake Mary, Longwood, Sanford, Seminole County, Winter Springs Date: f I hereby name and appoint: David Mercer an agent of: Park Square Homes Name of Company) to be my lawful attorney -in -fact to act for me to apply for, receipt for, sign for and do all things necessary to this appointment for (check only one option): 0 The specific permit and application for work Located at: Expiration Date for This Limited Power of Attorney: License Holder Name: Vishaal Gupta State License Number: CRC1330351 Signature of License Holder: STATE OF FLORIDA COUNTY OF Oranne The foregoing instrument was acknowledged before me this _& day oft rc ra.f 20W LE, by Vishaal Gupta who is Xpersonally known to me or o who has produced as identification and who did (did not) to an oath. 4V Si nature& - Notary Seal) MICHELLE PARKISON FloridaNotaryPublic -- State Of Flo ida Commission # GG 157861 Expires Nov 5,2021MyComm, Lon throughNjiumal NOWY A5811 Rev. 08.12) Print or type name Notary Public - State of Commission NO. I,c-- I MyCommission Ex'pires: , :x> a )l FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Lot 034 Sundance A LHG - N Builder Name: Street: 3908 Saltmarsh Loop Permit Office: C' Sa ford City, State, Zip: Sanford , FL , Permit Number: Owner: Park Square Homes Jurisdiction: 691500 Design Location: FL, Orlando County:: Seminole (Florida Climate Zon6k,,"2 1. New construction or existing New (From Plans) 9. Wall Types (2335.7 sqft.) Insulation '",--06a 2. Single family or multiple family Single-family a, Frame - Wood, Exterior R=l 1.0 1197,00 ft2 b. Concrete Block - Int Insul, Exterior R-4.1 886.67 112 3, Number of units, if multiple family 1 c. Frame - Wood, Adjacent R=1 1.0 252.00 ft2 4. Number of Bedrooms 4 d. N/A R= ft2 10, Ceiling Types (1054.0 sqft.) Insulation Area 5. Is this a worst case? No a. Under Attic (Vented) R=30,0 10 54. 00 ft2 6. Conditioned floor area above grade (W) 1730 b. N/A R= ft2 c. N/A R= ft2 Conditioned floor area below grade (W) 0 11. Ducts R ft2 7. Windows(181,0 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: 2nd Floor 6 346 a, U-Factor: Dbl, U=0.55 105.00 ft2 SHGC: SHGC-0,22 b. U-Factor: Dbl, U=0.58 64 00 112 12. Cooling systems kBtu/hr Efficiency SHGC: SHGCm0.25 a. Central Unit 34.8 SEER:16.00 c. U-Factor: Dbl, U=0.54 12.00 ft2 SHGC: SHGC=0.25 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Heat Pump 33,0 HSPF:9.00 SHGC: Area Weighted Average Overhang Depth: 3.475 ft. Area Weighted Average SHGC: 0.233 14. Hot water systems a. Electric Cap: 50 gallons 8, Floor Types (1730.0 sqft.) Insulation Area EF: 0,900 a. Slab -On -Grade Edge Insulation R=0.0 756.00 ft2 b, Conservation features b. Floor Over Other Space R=0.0 676.00 ft2 None c. other (see details) R= 298.00 W 15. Credits Pstat Glass/Floor Area: 0.105 Total Proposed Modified Loads: 56.18 PASS Total Baseline Loads: 57.96 1 hereby certify that the plans and specifications covered by Review of the plans and ST this calculation are in compliance with the Florida Energy specifications covered by this t f Code. Digitally signed by Michael calculation indicates compliance Michael Conway conway with the Florida Energy Code. Date: 2018.02.28 1010:25 -05'00' PREPARED BY: Before construction is completed 11 DATE: this building will be inspected for zkko' compliance with Section 553.908 I hereby certify that this building as- esigne is in compliance Florida Statutes. with the Florida Energ Co 0 WV OWNER/AGEN BUILDING OFFICIAL: DATE: DATE: Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). Compliance with a proposed duct leakage On requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.030 On for whole house. 2/28/2018 10:05 AM EnergyGaugeS USA - FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 5 F(-)PKA PA0C;-9n17 PROJECT Title: Lot 034 Sundance A LHG - N Bedrooms: 4 Address Type: Lot Information Building Type: User Conditioned Area: 1730 Lot # 34 Owner Name: Park Square Homes Total Stories: 2 Block/Subdivision: WP of Units: I Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street: 3908 Saltmarsh Loop Permit Office: City of Sanford Cross Ventilation: No County: Seminole Jurisdiction: 691500 Whole House Fan: No City, State, Zip: Sanford , Family Type: Single-family FL , NewiExisting: New (From Plans) Comment: CLIMATE V Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range FL, Orlando FL—ORLANDO—INTL—AR 41 91 70 75 526 44 Medium BLOCKS Number Name Area Volume 1 Blockl 1730 15796,8 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 1 st Floor 756 7030.8 Yes 0 1 Yes Yes Yes 2 2nd Floor 974 8766 No 5 4 1 Yes Yes Yes FLOORS mme # Floor Type Space Perimeter Perimeter R-Value Area — Joist R-Value Tile Wood Carpet 1 Raised Floor 2nd Floor ---- ---- 110 ft2 11 0.29 0 0.71 2 Floor over Garage 2nd Floor ---- ---- 188 ft2 11 0.29 0 0.71 3 Slab -On -Grade Edge Insulatio 1 st Floor 95 ft 0 756 ft2 0.29 0 0.71 4 Floor Over Other Space 2nd Floor ---- ---- 676 ft2 0 0.29 0 0.71 ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. deg) 1 Hip Composition shingles 1179 ft2 0 ft2 Dark 0.9 N 0.9 No 0 26.6 ATTIC V# Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 1054 ft2 N N 2/28/2018 10:05 AM EnergyGauge(& USA - FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 5 FC)RNA R4n.q-pnl7 CEILING Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) 1 st Floor 30 Blown 1054 ft- 0.1 Wood WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Spa 1 N Exterior Frame - Wood 2nd Floor 11 30 0 9 0 270,0 ft2 0 0.25 0.8 0 2 N Exterior Concrete Block - Int Insul 1 st Floor 4.1 9 6 9 4 88.7 112 0 0 0.8 0 3 E Exterior Frame - Wood 2nd Floor 11 36 6 9 0 328.5 ft2 0 0.25 0.8 0 4 E Exterior Concrete Block - Int Insul I st Floor 4.1 24 6 9 4 228.7 ft2 0 0 0,8 0 5 S Exterior Frame - Wood 2nd Floor 11 30 0 9 0 270.0 ft2 0 0,25 0.8 0 6 S Exterior Concrete Block - Int Insul I st Floor 4.1 30 0 9 4 280.0 ft2 0 0 0.8 0 7 W Exterior Frame - Wood 2nd Floor 11 36 6 9 0 328.5 ft2 0 0.25 0.8 0 8 W Exterior Concrete Block - Int Insul 1 st Floor 4.1 31 0 9 4 289.3 ft2 0 0 0.8 0 9 Garage Frame - Wood I st Floor 11 27 0 9 4 252.0 ft2 0 0.25 0.8 0 DOORS V Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In I N Insulated 1st Floor None 4 3 8 24 ft2 2 Wood 1st Floor None 39 2 8 8 21.3 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. Wall Overhang Ornt ID Frame Panes- NFRC, U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 N I Metal Low-E Double Yes 0,55 0.22 N 30.0 ft' 1 ft 0 in 1 It 0 in Drapes/blinds None 2 e 3 Metal Low-E Double Yes 0.55 0.22 N 15.0 ft' 1 ft 0 in 1 It 0 in Drapes/blinds None 3 e 3 Metal Low-E Double Yes 0.54 0.25 N 4.0 W 1 ft 0 in 1 It 0 in Drapes/blinds None 4 s 5 Metal Low-E Double Yes 0.55 0.22 N 30.0 ft' 1 ft 0 in 1 It 0 in Drapes/blinds None 5 s 6 Metal Low-E Double Yes 0.55 0.22 N 30.0 ft' I It 0 in 12 It 0 in Drapes/blinds None 6 S 6 Metal Low-E Double Yes 0.58 0.25 N 64.0 It' 8 It 0 in 1 It 0 in None None 7 w 7 Metal Low-E Double Yes 0.54 0.25 N 4.0 ft' 1 It 0 in 1 If 0 in Drapes/blinds None 8 W 8 Metal Low-E Double Yes 0.54 0.25 N 4.0 It' I ft 0 in 12 It 0 in Drapes/blinds None GARAGE Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 439 ft2 439 f12 64 ft 9,3 ft 1 2/28/2018 10:05 AM EnergyGaugeOq USA - FlaRes2017 Section R405.4,1 Compliant Software Page 3 of 5 FORM R405-2017 INFILTRATION Scope Method SLA CFM 50 ELA EqLA ACH ACH 50 1 Wholehouse Proposed ACH(50) 000406 1843 101.18 190.28 365 7 HEATING SYSTEM System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ split HSPF:9 33 kBtu/hr 1 sys#1 COOLING SYSTEM System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 16 34.8 kBtu/hr 1044 cfm 0.75 1 sys#1 HOT WATER SYSTEM System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.9 50 gal 70 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft-, DUCTS Supply ---- Return ---- Air CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic 6 346 ft2 Attic 86.5 ft2 Prop. Leak Free 2nd Floor --- cfm 51.9 cfm 0,03 0.50 1 1 TEMPERATURES Prograrnable Thermostat: Y Ceiling Fans: CoolinJan Feb Mar Apr May Jun Julug Sep Oct Nov Dec HeatingJan Feb Mar HHXApr May Jun Julug Sep 1 xl 1 11 Octov tHXDec HVenJanFebMarAprMayJunJulAugSepOctNovDec2/ 28/2018 10:05 AM EnergyGaugeS USA - FlaRes2017 Section R405.4,1 Compliant Software Page 4 of 5 FORM R405-2017 Thermostat Schedule: HERS 2006 Reference Schedule Type 1 2 Cooling (WD) AM 78 78 PM 80 80 Cooling (WEH) AM 78 78 PM 7 788 Heating (WD) AM 66 66 PM 68 68 Heating (WEH) AM 66 66 PM 68 68 Hours 3 4 5 6 7 8 9 10 11 12 78 78 78 78 78 78 80 80 80 80 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 66 66 66 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 66 66 66 66 66 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 66 66 2/28,12018 10:05 AM EnergyGauge(& USA - FlaRes2017 Section R405.4.1 Compliant Software Page 5 of 5 Florida Building Code, Energy Conservation, 6th Edition (2017) Mandatory Requirements for Residential Performance, PrescriEtive and ERI Methods 3908 Saltmarsh Loop Permit Number: Sanford , FL , MANDATORY REQUIREMENTS See individual code sections for full details. SECTION R401 GENERAL R401.3 Energy Performance Level (EPL) display card (Mandatory). The building official shall require that an energy performance level (EPL) display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy. Florida law Section 553.9085, Florida Statutes) requires the EPL display card to be included as an addendum to each sales contract for both presold and nonpresold residential buildings. The EPL display card contains information indicating the energy performance level and efficiencies of components installed in a dwelling unit. The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans and specifications submitted to demonstrate code compliance for the building. A copy of the EPL display card can be found in Appendix RD. R402.4 Air leakage (Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of Sections R402.4.1 through R402.4.5. Exception: Dwelling units of R-2 Occupancies and multiple attached single family dwellings shall be permitted to comply with Section C402.5. R402.4.1 Building thermal envelope. The building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2. The sealing methods between dissimilar materials shall allow for differential expansion and contraction. R402.4.1.1 Installation.The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance with the manufacturer's instructions and the criteria listed in Table R402.4.1.1, as applicable to the method of construction. Where required by the code official, an approved third party shall inspect all components and verify compliance. R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate not exceeding seven air changes per hour in Climate Zones 1 and 2, and three air changes per hour in Climate Zones 3 through 8. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w,g. (50 pascals). Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(f), (g) or (i) or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official, Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. Exception: Testing is not required for additions, alterations, renovations, or repairs, of the building thermal envelope of existing buildings in which the new construction is less than 85 percent of the building thermal envelope. During testing: 1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or other infiltration control measures. 2. Dampers including exhaust, intake, makeup air, backdraft and flue dampers shall be closed, but not sealed beyond intended infiltration control measures, 3. Interior doors, if installed at the time of the test, shall be open. 4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5. Heating and cooling systems, if installed at the time of the test, shall be turned off, 6. Supply and return registers, if installed at the time of the test, shall be fully open. R402.4.2 Fireplaces. New wood -burning fireplaces shall have tight -fitting flue dampers or doors, and outdoor combustion air. Where using tight -fitting doors on factory -built fireplaces listed and labeled in accordance with UL 127, the doors shall be tested and listed for the fireplace. Where using tight -fitting doors on masonry fireplaces, the doors shall be listed and labeled in accordance with UL 907. R402.4.3 Fenestration air leakage Windows, skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm per square foot (1.5 L/s/m2), and swinging doors no more than 0.5 cfm per square foot (2.6 L/s/m2), when tested according to NFRC 400 or AAMA/ WDMA/CSA 101 /I.S.2/A440 by an accredited, independent laboratory and listed and labeled by the manufacturer. Exception: Site -built windows, skylights and doors. 2/28/2018 10:05 AM EnergyGaugeO USA - FlaRes2017 - FBC 6th Edition (2017) Complia Page 1 of 5 MANDATORY REQUIREMENTS - (Continued) R402.4.4 Rooms containing fuel -burning appliances. In Climate Zones 3 through 8, where open combustion air ducts provide combustion air to open combustion fuel burning appliances, the appliances and combustion air opening shall be located outside the building thermal envelope or enclosed in a room, isolated from inside the thermal envelope. Such rooms shall be sealed and insulated in accordance with the envelope requirements of Table R402.1.2. where the walls, floors and ceilings shall meet not less than the basement wall R-value requirement. The door into the room shall be fully gasketed and any water lines and ducts in the room insulated in accordance with Section R403. The combustion air duct shall be insulated where it passes through conditioned space to a minimum of R-8. Exceptions: 1, Direct vent appliances with both intake and exhaust pipes installed continuous to the outside. 2. Fireplaces and stoves complying with Section R402.4.2 and Section R 1006 of the Florida Building Code, Residential. R402.4.5 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage between conditioned and unconditioned spaces. All recessed luminaires shall be IC -rated and labeled as having an air leakage rate not more than 2.0 cfm (0.944 L/s) when tested in accordance with ASTM E283 at a 1.57 psf (75 Pa) pressure differential. All recessed luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering, SECTION R403 SYSTEMS R403.1 Controls. R403.1.1 Thermostat provision (Mandatory). At least one thermostat shall be provided for each separate heating and cooling system. R403.1.3 Heat pump supplementary heat (Mandatory). Heat pumps having supplementary electric -resistance heat shall have controls that, except during defrost, prevent supplemental heat operation when the heat pump compressor can meet the heating load. R403.3.2 Sealing (Mandatory) All ducts, air handlers, filter boxes and building cavities that form the primary air containment passageways for air distribution systems shall be considered ducts or plenum chambers, shall be constructed and sealed in accordance with Section C403.2.9.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria below. Duct tightness shall be verified by testing in accordance with ANSI/RESNET/ICC 380 by either individuals as defined in Section 553.993(5) or 7), Florida Statutes, or individuals licensed as set forth in Section 489,1 05(3)(f), (g) or (i), Florida Statutes, to be "substantially leak free" in accordance with Section R403.3.3. R403.3.2.1 Sealed air handier. Air handlers shall have a manufacturer's designation for an air leakage of no more than 2 percent of the design airflow rate when tested in accordance with ASHRAE 193. R403.3,3 Duct testing (Mandatory). Ducts shall be pressure tested to determine air leakage by one of the following methods: Rough -in test: Total leakage shall be measured with a pressure differential of 0.1 inch w.g. (25 Pa) across the system, including the manufacturer's air handler enclosure if installed at the time of the test. All registers shall be taped or otherwise sealed during the test. Postconstruction test: Total leakage shall be measured with a pressure differential of 0.1 inch w.g. (25 Pa) across the entire system, including the manufacturer's air handler enclosure. Registers shall be taped or otherwise sealed during the test. Exceptions: 1, A duct air leakage test shall not be required where the ducts and air handlers are located entirely within the building thermal envelope, 2. Duct testing is not mandatory for buildings complying by Section 405 of this code. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. R403.3.5 Building cavities (Mandatory). Building framing cavities shall not be used as ducts or plenums. R403.4 Mechanical system piping insulation (Mandatory). Mechanical system piping capable of caning fluids above 105°F (41 1C) or below 55°F (1 3C) shall be insulated to a minimum of R-3. R403.4.1 Protection of piping insulation. Piping insulation exposed to weather shall be protected from damage, including that caused by sunlight, moisture, equipment maintenance and wind, and shall provide shielding from solar radiation that can cause degradation of the material. Adhesive tape shall not be permitted. R403.5.1 Heated water circulation and temperature maintenance systems (Mandatory). Heated water circulation systems shall be in accordance with Section R403.5.1.1. Heat trace temperature maintenance systems shall be in accordance with Section R403.5.1.2. Automatic controls, temperature sensors and pumps shall be accessible. Manual controls shall be readily accessible. R403.5.1.1 Circulation systems. Heated water circulation systems shall be provided with a circulation pump. The system return pipe shall be a dedicated return pipe or a cold water supply pipe. Gravity and thermosiphon circulation systems shall be prohibited. Controls for circulating hot water system pumps shall start the pump based on the identification of a demand for hot water within the occupancy. The controls shall automatically turn off the pump when the water in the circulation loop is at the desired temperature and when there is no demand for hot water. R403.5.1.2 Heat trace systems. Electric heat trace systems shall comply with IEEE 515.1 or UL 515. Controls for such systems shall automatically adjust the energy input to the heat tracing to maintain the desired water temperature in the piping in accordance with the times when heated water is used in the occupancy. 2/28/2018 10:05 AM EnergyGaugeO USA - FlaRes2017 - FBC 6th Edition (2017) Complian Page 2 of 5 MANDATORY REQUIREMENTS - (Continued) R403.5.5 Heat traps (Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have heat traps installed on both the inlets and outlets. External heat traps shall consist of either a commercially available heat trap or a downward and upward bend of at least 3 1/2 inches (89 mm) in the hot water distribution line and cold water line located as close as possible to the storage tank, R403.5.6 Water heater efficiencies (Mandatory). R403.5.6.1.1 Automatic controls. Service water -heating systems shall be equipped with automatic temperature controls capable of adjustment from the lowest to the highest acceptable temperature settings for the intended use. The minimum temperature setting range shall be from 1 001F to 140°F (38°C to 60*C). R403.5.6.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to electric service systems to be turned off. A separate valve shall be provided to permit the energy supplied to the main burner(s) of combustion types of service water -heating systems to be turned off. R403.5.6.2 Water -heating equipment. Water -heating equipment installed in residential units shall meet the minimum efficiencies of Table C404,2 in Chapter 4 of the Florida Building Code, Energy Conservation, Commercial Provisions, for the type of equipment installed. Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water -heating category. Solar water heaters shall meet the criteria of Section R403.5.6.2.1. R403.5.6.2.1 Solar water -heating systems. Solar systems for domestic hot water production are rated by the annual Solar energy factor of the system. The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of Certified Solar Systems. Solar collectors shall be tested in accordance with ISO Standard 9806, Test Methods for Solar Collectors, and SRCC Standard TM-1, Solar Domestic Hot Water System and Component Test Protocol. Collectors in installed solar water -heating systems should meet the following criteria: 1. Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal; and 2. Be installed at an orientation within 45 degrees of true south. R403.6 Mechanical ventilation (Mandatory). The building shall be provided with ventilation that meets the requirements of the Florida Building Code, Residential, or Florida Building Code, Mechanical, as applicable, or with other approved means of ventilation including: Natural, Infiltration or Mechanical means. Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system is not operating. 8403.6.1 Whole -house mechanical ventilation system tan efficacy. When installed to function as a whole -house mechanical ventilation system, fans shall meet the efficacy requirements of Table R403.6.1. Exception: Where whole -house mechanical ventilation fans are integral to tested and listed HVAC equipment, they shall be powered by an electronically commutated motor. R403.6.2 Ventilation air. When installed to function as a whole -house mechanical ventilation system, fans shall meet the efficacy requirements of Table R403.6.1. 1. The design air change per hour minimums for residential buildings in ASHRAE 62.2, Ventilation for Acceptable Indoor Air Quality, shall be the maximum rates allowed for residential applications, 2. No ventilation or air-conditioning system make-up air shall be provided to conditioned space from,attics, crawlspaces, attached enclosed garages or outdoor spaces adjacent to swimming pools or spas, 3• If ventilation air is drawn from enclosed space(s), then the walls of the space(s) from which air is drawn shall be insulated to a minimum of R-1 1 and the ceiling shall be insulated to a minimum of R-1 9, space permitting, or R-10 otherwise. R403.7 Heating and cooling equipment (Mandatory). R403.7.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies, based on building loads for the directional orientation of the building. The manufacturer and model number of the outdoor and indoor units (if split system) shall be submitted along with the sensible and total cooling capacities at the design conditions described in Section R302. 1. This Code does not allow designer safety factors, provisions for future expansion or other factors that affect equipment sizing. System sizing calculations shall not include loads created by local intermittent mechanical ventilation such as standard kitchen and bathroom exhaust systems. New or replacement heating and cooling equipment shall have an efficiency rating equal to or greater than the minimum required by federal law for the geographic location where the equipment is installed. TABLE R403.6.1 WHOLE -HOUSE MECHANICAL VENTILATION SYSTEM FAN EFFICACY FAN LOCATION AIRFLOW RATE MINIMUM CFM) MINIMUM EFFICACY aAIRFLOW CFM/WATT) RATE MAXIMUN CFM) Range hoods Any 2.8 cfm/watt Any In -line fan Any 2.8 cfm/watt Any Bathroom, utility room 10 1.4 cfm/watt 90 FBathroom, utility room 90 2.8 cfm/watt Any For SI: I cfm = 28.3 Umin. a. When tested in accordance with HVI Standard 916 2/28/2018 10:05 AM EnergyGaugeO USA - FlaRes2017 - FBC 6th Edition (2017) Complia Page 3 of 5 MANDATORY REQUIREMENTS - (Continued) R403.7.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less than the calculated total load but not more than 1.15 times greater than the total load calculated according to the procedure selected in Section 403.7, or the closest available size provided by the manufacturer's product lines. The corresponding latent capacity of the equipment shall not be less than the calculated latent load. The published value for AHRI total capacity is a nominal, rating -test value and shall not be used for equipment sizing. Manufacturer's expanded performance data shall be used to select cooling -only equipment. This selection shall be based on the outdoor design dry-bulb temperature for the load calculation (or entering water temperature for water -source equipment), the blower CFM provided by the expanded performance data, the design value for entering wet -bulb temperature and the design value for entering dry-bulb temperature. Design values for entering wet -bulb and dry-bulb temperatures shall be for the indoor dry bulb and relative humidity used for the load calculation and shall be adjusted for return side gains it the return duct(s) is installed in an unconditioned space. Exceptions: 1 Attached single- and multiple -family residential equipment sizing may be selected so that its cooling capacity is less than the calculated total sensible load but not less than 80 percent of that load. 2. When signed and sealed by a Florida -registered engineer, in attached single- and multiple -family units, the capacity of equipment may be sized in accordance with good design practice. R403.7.1.2 Heating equipment capacity. R403.7.1.2.1 Heat pumps. Heat pump sizing shall be based on the cooling requirements as calculated according to Section R403.7.1.1, and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load even if the design heating load is 1.15 times greater than the design cooling load. R403.7.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design requirements calculated according to the procedure selected in Section R403.7. I. R403.7.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners shall not be less than the design load calculated in accordance with Section R403.7.1. R403.7.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an intermittent basis, such as anticipated additional loads caused by major entertainment events, shall have equipment sized or controlled to prevent continuous space cooling or heating within that space by one or more of the following options: 1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas. 2. A variable capacity system sized for optimum performance during base load periods is utilized. R403.8 Systems serving multiple dwelling units (Mandatory). Systems serving multiple dwelling units shall comply with Sections C403 and C404 of the IECC—Commercial Provisions in lieu of Section R403. R403.9 Snow melt and ice system controls (Mandatory) Snow- and ice -melting systems, supplied through energy service to the building, shall include automatic controls capable of shutting off the system when the pavement temperature is above 50°F (1 O*C), and no precipitation is failing and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40°F (4.81C). R403.1 0 Pools and permanent spa energy consumption (Mandatory). The energy consumption of pools and permanent spas shall be in accordance with Sections R403. 10.1 through R403. 10.5. R403.10.1 Heaters. The electric power to heaters shall be controlled by a readily accessible on -off switch that is an integral part of the heater mounted on the exterior of the heater, or external to and within 3 feet (914 mm) of the heater. Operation of such switch shall not change the setting of the heater thermostat. Such switches shall be in addition to a circuit breaker for the power to the heater. Gas -fired heaters shall not be equipped with continuously burning ignition pilots, R403.10.2 Time switches. Time switches or other control methods that can automatically turn off and on according to a preset schedule shall be installed for heaters and pump motors. Heaters and pump motors that have built-in time switches shall be in compliance with this section. Exceptions: 1. Where public health standards require 24-hour pump operation. 2. Pumps that operate solar- and waste -heat -recovery pool heating systems. 3. Where pumps are powered exclusively from on -site renewable generation. R403.10.3 Covers. Outdoor heated swimming pools and outdoor permanent spas shall be equipped with a vapor -retardant cover on or at the water surface or a liquid cover or other means proven to reduce heat loss. Exception: Where more than 70 percent of the energy for heating, computed over an operation season, is from site -recovered energy, such as from a heat pump or solar energy source, covers or other vapor -retardant means shall not be required. R403.10.4 Gas- and oil -fired pool and spa heaters. All gas- and oil -fired pool and spa heaters shall have a minimum thermal efficiency of 82 percent for heaters manufactured on or after April 16, 2013, when tested in accordance with ANSI Z 21.56. Pool heaters fired by natural or LP gas shall not have continuously burning pilot lights. 2/28/2018 10:05 AM EnergyGaugeO USA - FlaRes2017 - FBC 6th Edition (12017) Complia Page 4 of 5 R403.10.5 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance with AHRI 1160, Table 2, Standard Rating Conditions -Low Air Temperature. A test report from an independent laboratory is required to verify procedure compliance. Geothermal swimming pool heat pumps are not required to meet this standard. R403.11 Portable spas (MandatorY)he energy consumption of electric -powered portable spas shall be controlled by the requirements of APSP-1 4. SECTION R404 ELECTRICAL POWER AND LIGHTING SYSTEMS R404.1 Lighting equipment (Mandatory). Not less than 75 percent of the lamps in permanently installed lighting fixtures shall be high -efficacy lamps or not less than 75 percent of the permanently installed lighting fixtures shall contain only high -efficacy lamps, Exception: Low -voltage lighting, R404.1.1 Lighting equipment (Mandatory). Fuel gas lighting systems shall not have continuously burning pilot lights. 2/28/2018 10:05 AM EnergyGaugeO USA - FlaRes2017 - FBC 6th Edition (2017) Complia Page 5 of 5 FORM R405-2017 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 97 The lower the EnergyPerformance Index, the more efficient the home. 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5, Is this a worst case? 6. Conditioned floor area (W) 7. Windows- Description a. U-Factor: Dbl, U=0,55 SHGC: SHGC=0.22 b. U-Factor: Dbl, U=0.58 SHGC: SHGC=0.25 c. U-Factor: Dbl, U=0.54 SHGC: SHGC=0.25 d. U-Factor: N/A SHGC: Area Weighted Average Overhang Depth Area Weighted Average SHGC: 3908 Saltmarsh Loop, Sanford, FL, New (From Plans) 9, Wall Types Insulation Area Single-family a. Frame - Wood, Exterior R=1 1,0 1197.00 ft2 b. Concrete Block - Int Insul, Exterior R=4.1 886.67 ft2 1 c. Frame - Wood, Adjacent R=1 1.0 252.00 ft2 4 d. N/A R= ft2 10. Ceiling Types Insulation Area No a. Under Attic (Vented) R=30.0 1054.00 ft2 1730 b. N/A R= ft2 c. N/A R= ft2 Area 11. Ducts R W 105,00 ft2 a. Sup: Attic, Ret: Attic, AH: 2nd Floor 6 346 64.00 ft2 12. Cooling systems kBtu/hr Efficiency 12.00 ft2 a. Central Unit 34.8 SEER:16.00 H 3,475 ft. 0.233 8. Floor Types Insulation Area a. Slab -On -Grade Edge Insulation R-0.0 756.00 ft2 p. Floor Over Other Space R=0.0 676.00 ft2 c. other (see details) R= 298.00 ft2 13. Heating systems a. Electric Heat Pump 14. Hot water systems a. Electric b. Conservation features None 15. Credits I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Gade ca ant feat es. I Builder Signature., Date: R. I p, Address of New Home: '29,0& City/FL Zip: kBtu/hr Efficiency 33.0 HSPF:9,00 Cap: 50 gallons EF: 0.9 Pstat Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 2/28/2018 10:05 AM EnergyGaugeS USA - FlaRes2017 - Section R405,41 Compliant Software Page 1 of 1 Project Summary Job: Lot 034 Sundance A LH G wrightsoft- Date: 02/27/2018 Entire House By. LFRUMCIATMC One Stop Cooling and Heating 7225 Sandscove Gout Winer Park, FL 32792 Phone (407)629-6920 Fax 14071629-9307 Web: wwwOreStopCoolirg.com License: CAGO32444 for X166" For: Park Square Homes 3908 SaItmarsh Loop, Sanford, FL Notes: Weather: Orlando Inti AP, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 92 OF Inside db 68 OF Inside db 74 OF Design TD 26 OF Design TD 18 OF Daily range M Relative midity 50 Moisture difference 49 grAb Heating Summary Sensible Cooling Equipment Load Sizing Structure 17390 Btuh Structure 17990 Btuh Ducts 2364 Btuh Ducts 6764 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh none} none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 19753 Btuh Use manufacturer's data n Rate/swina multiplierEquipmentload 0.97 24110 BtuhInfiltrationsensible Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 3142 Btuh Ducts 1381 Btuh Central vent (0 cfm) 0 Btuh Heat*n Cooling none) Area (ft2) 1 1794 Equipment latent load 4523 Btuh Volume (ft3) 16368 16368 Airchangesibour 0.50 0.26 Equipment Total Load (Sen+Lat) 28633 Btuh Equiv. AVF (cfm) 136 71 Req. total capacity at 0.75 SHR 2.7 ton Heating Equipment Summary Cooling Equipment Summary Make Trane Make Trane Trade TRANE Trade TRANE Model 4TWR6036H1 Cond 4TWR6036H1 AHRI ref 7562981 Coil TEM6AOC36H31 ++TDR AHRI ref 7562981 Efficiency 9 HSPF Efficiency 13.0 EER, 16 SEER Heating input Sensible cooling 26100 Btuh Heating output 33000 Btuh @ 47°F Latent cooling 8700 Btuh Temperature rise o OF Total cooling 34800 Btuh Actual air flow 0 cfm Actual air flow 1160 cfm Air flow factor 0 cfm/Btuh Air flow factor 0,047 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.85 Capacity balance point = 29 OF Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2018-Feb-27 14:02:40 Rigid-SuteO Unversal 2018 18.0.11 RSU25029 Page 1 ACCk ...ante A LHG - N\Lot 034 Sumiarre A LHG - N.rup Calc = MJ8 House faces: N LL 7T wrightsoft, Right-JO Worksheet Entire House One Stop Cooling and Heating 7225 Sardscove Court, Wirwr Park, F1- 32792 Phone: (407) 629 - 6920 Fax:(401) 629 - 9307 Web: w,&w0neStopCooIirq.corn License: CAC032444 Job: Lot 034 Sundance A LHG - N Date: 02127/2018 By. LF/RI/MC/AT/MC I Room name Entire House FOY 2 Exposed wall 227,5 It 5.0 ft 3 Room height 9.1 If d 93 If heaticool 4 Room dimensions 5.5 x 16-5 it 5 Room area 1793.8 112 90.8 it, Ty Construction number U-value 6tuW-1,F) Or HTM Btuh/W) Area (ft) or perimeter (ft) Load Btuh) Area (fr) or perimeter (ft) Load Btuh) Heat Cool I Gross NP/S Heat Cool Gross N/Ps Heat Cool 6 vF1 1213-0sw 485-2fm 13A-4ocs 0.097 0-140 0.143 n n n Z53 14M 3,73 2.82 13.67 2.90 329 4 288 325 0 284 822 56 1061 914 55 823 0 0 0 0 0 0 0 0 0 0 0 0 11 485-2frn 126-0sw 0540 0,097 n e 14.09 2.53 13.67 282 4 270 0 240 56 608 55 676 0 0 0 0 0 0 0 0W 4A5-2orn 13A-4ocs 1 1DO 0,550 0.143 0.390 e e e 14-35 3.73 10.18 27.44 2.90 12.27 30 84 24 0 60 24 431 223 244 823 173 294 0 47 24 0 23 24 0 84 244 0 65 294t-D 12B-Ow 4A5-2om 0.097 0,550 s s 2,53 14.35 2,82 13.54 329 15 310 13 784 215 872 203 0 0 0 0 0 0 0 0 W t-G 485-2fm 13A-flocs 1213-09N 4A5-2am 13A-4ocs 0.540 OJ43 0.097 0-550 0.143 s s w w w 14.09 3.73 2,53 1435 3.73 13.67 2.90 Z82 27.44 2.90 4 228 270 30 279 4 228 240 0 185 56 850 608 431 690 55 660 676 823 536 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 4A5-2om 4A5-2omd 12C-0sw 0550 0.580 0.091 w w 14.35 15.14 Z38 27.44 21.44 1.51 30 64 256 0 45 234 431 969 557 823 1372 353 0 0 33 0 0 33 0 0 77 0 0 49P L D 11DO 16B-30ad 0.390 0,032 n 10.18 0.84 1227 1.76 21 1046 21 1046 217 873 262 1838 0 0 0 0 0 0 0 0G F 19A-ObsT 0295 2.89 2-04 108 108 312 220 0 0 0 0 F 19C-19csop 0.049 0.44 0.31 189 189 84 59 0 0 0 0 F 22A-tam 1.180 30.80 0.00 748 95 2910 0 91 5 154 0 6 c) AED e)mrsion 13721 17 Envelope loss/gain 13488 13939 560 392 12 a) Infiltration 3901 1430 87 32 b) Room ventilation 0 a 0 0 13 Internal gains: 0owpants @ 230 4 920 0 0 Appfianoesrother 1 1700 1 0 Subtotal (lines 6 to 13) 17390 17990 647 1 424 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 647 424 14 Subtotal 17390 17990 0 0 15 Dud loads 1 14% 38% 2364 6764 14%l 43% 0 01 Total room load 19753 24754 0 0 Air required (dm) 0 1160, 1 0 0 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. PJ4- 2018-Feb-27 14.02:40 Right-SLateO Uriversal 2018 18.0.11 RSU25029 Page I arre ALHG N1ot034 SLrdarre ALHG - N.rLP Calc - M,18 House faces: N d 1 77 wrightsoft, Right-J@ Worksheet Entire House One Stop Cooling and Heating 7225 Sarxi scove Court, W trier Park, FL 32792 Plane: (4 07) 629.6920 Fax: (407)629-9307 Web: www.0r)eStopCooling.com License: CA0032444 Job: Lot 034 Sundance A LH G - N Date: 02/2712018 B)r. LF/R1/MC/AT/MC 1 Room name GATH STR1 2 Exlaoseclhell 37.0 If 22.5 It 3 Room height 9.3 It heaticool 9.3 It heat'dool 4 Room dimensions 1,0 x 231,3 It 4.0 x 18,5 it 5 Room area 231.3 ft" 74,0 It2 Ty Construction number U-value Btuh/ft-fl or HTM BtuhiW) Area (it) or perimeter (ft) Load Blun) Area (ft) or perimeter (ft) Load Btuh) Heat Cool Gross NP/S Heat Cool Gross N/PiS Heat cool 6 t--G 12B-0stN 0.097 n 2,53 2.82 0 0 0 0 0 0 0 0 465-2tm 0.540 n 14.09 13.67 0 0 0 0 0 0 0 0 t---G 13A-4ocs 0.143 n 173 2.90 116 116 434 337 172 168 627 487 485-2frn 0.540 n 14.09 13.67 0 0 0 0 4 0 56 55 ilrt11 12B-Osw 0.097 e 2.53 2.82 0 0 0 0 0 0 0 0 4A5-tam 0.550 e 14.35 27.44 0 0 0 0 0 0 0 0 Y-D 13A-flocs 0.143 e 173 Z90 0 0 0 0 37 37 139 108 1 1DO 0.390 e 10,18 12.27 0 0 0 0 0 0 0 0 12B-09m 0.097 s 253 2.82 0 0 0 0 0 0 0 0 T:f2 4A5-2om 0.550 s 14.35 13.54 0 0 0 0 0 0 0 0 w 4135-2trn 13A-flocs 0.540 0.143 s s 14,09 3.73 13.67 2.90 0 74 0 74 0 278 0 215 0 0 0 0 0 0 0 0 t--G 12B-09.v 0.097 w 2,53 Z82 0 0 0 0 0 0 0 0 4A5-2om O,W) w 14.35 27.44 0 0 0 0 0 0 0 0 13A-4ocs 0.143 w 3.73 2,90 153 123 461 357 0 0 0 0 4A5-2orn 0.550 w 14.35 27.44 30 0 431 823 0 0 0 0 R 4A5-2omd 12C-Osw 0.580 0.091 w 1514 2,38 21.44 1.51 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 11DO 0.390 n 10.18 12.27 0 0 0 0 0 0 0 0 C 16B-30ad 0.032 0.84 1.76 0 0 0 0 0 0 0 0 F 1 9A-0bscp 0295 2,89 204 0 0 0 0 0 0 0 0 F 19C-19csM 0.049 0.44 0.31 0 0 0 0 0 0 0 0 F 22A-Ipm 1,180 30,80 0,00 231 37 1140 0 74 23 693 0 6 c) AED excursion 270 30 Envelope loss/gain 2742 2003 15151 619 12 a) Infiltration 647 237 393 144 b) Room venfilat I on 0 0 1 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliancesiother 0 0 Subtotal (lines 6 to 13) 3389 2240 1909 763 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 2096 886 1909 763 14 Subtotal 5485 3126 0 0 15 Duct loads 14/. 41 772 1352 141%1 43% 0 0 Total room load 6257 4478 Air required (drn) 0 210 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. 2018-Feb-27 14.02.40 Right-SuteOUrvversal 2018 18.0,11 RSU25029 Page 2 ante A LHG - N\Lot 034 Su dame A LHG - N,rup Cale - W8 House tares: N AL. rF wrightsoft, Right-JO Worksheet Entire House One Stop Cooling and Heating 7225 Sardscove Court, Winer Park, FL 32792 Phone: (40T) 629 - 6920 Fax: (407) 629 - 9307 Web: www.OreStopCooliN.com License: CAC032444 Job: Lot 034 Sundance A LHG - N Date: 02/27/2018 By. LFRUMCAPMC 1 Room name KIT DIN 2 Exposed wall 0 It 265 ft 3 Room height 9.3 It heatfcool 9.3 It heat/Cool 4 Room dimensions 1.0 x 183A It 1.0 x 142,6 it 5 Room area 183.4 fr 142.6 ft' Ty Construction U-value or HTM Area (ft') Load Area (ft--) Load number Btuh/IF-+) B or perimeter (ft) B h) or perimeter (ft) Btuh) Heat Cool Gross N/P(S Heat Cool G,.. NP/S Heat Cool 6 Vi1 12&Osw 0,097 n 2-53 2.82 0 0 0 0 0 0 0 0 485-211m 0.540 n 14.09 1167 0 0 0 0 0 0 0 0 t--G 13A-4ocs 0.143 n 3.73 2,90 0 0 0 0 0 0 0 0 4135-21rin 0.540 n 14.09 1167 0 0 0 0 0 0 0 0 V11 12B-Osw 0,097 e 253 2.82 0 0 0 0 0 0 0 0 4A5-2orn 0550 e 14,35 27.44 0 0 0 0 0 0 0 0G 1 3A-does 0,143 e 3.73 2.90 0 0 0 0 0 0 0 0 t-D 1100 0.390 e 10.18 1227 0 0 0 0 0 0 0 0 120-0,9m 0.097 a 253 2,82 0 0 0 0 0 0 0 0 4A5-2om 0.550 s 14,35 13.54 0 0 0 0 0 0 0 0 4E5,2(m 0-540 s 14,09 13.67 0 0 0 0 0 0 0 0 W 13A-flocs 0J43 s 3.73 2.90 0 0 0 0 121 121 451 3150 12B-Ow 0497 w 253 2.82 0 0 0 0 0 0 0 0 4A5-2om 13A-flocs 0.550 0.14.3 w w 14.35 3.73 27.44 2.90 0 0 0 0 0 0 0 0 0 126 0 62 0 230 0 178 4A5-20M 4A5-2omd 0550 0.580 w w 14.35 15A4 27.44 21.44 0 0 0 0 0 0 0 0 0 64 0 45 0 969 0 1372 T-D 2C-0sw 0.091 238 1.51 191 169 402 255 0 0 0 0 1100 0,390 n 10,18 1227 21 21 217 262 0 0 0 0 C 16B-30ad 0.032 0.84 1.76 0 0 0 0 0 0 0 0 F I 9A-0t)sT 0295 2.89 204 0 0 0 0 0 0 0 0 F 19C-19cscp 0.049 0A4 0.31 0 0 0 0 0 0 0 0 F 22A-tr)m 1180 30.80 0.00 183 0 0 0 143 27 816 0 6 c) AED excursion 651 1 1076 Envelope loss/gain 619 452 24661 2977 12 a) Infiltration 0 0 463 170 b) Room ventilation 0 0 0 0 13 Internal gains: O=pants @ 230 0 0 0 0 AppliancesVother 1200 0 Subtotal (lines 6 to 13) 619 16521 29291 3147 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 460 301 0 0 14 Subtotal 1079 1953 2929 3147 15 Duct loads 14] 43] 152 845 14% 43% 412 13611 Total room load 1231 2797 3341 4508 Air required (ctm) 01 131 0 211 Calculations approved by ACCA to meet all requirements of Manual j8th Ed. Pl*- 2018-Feb-27 1402 40 ZckA( Righ-SuteO Unversal 2018 18.011 RSU25029 Page 3 -., Arr ,e A LHG - N'Lot 034 Sundarice A LHG - N.rvp Calc - MJ8 House faces: N J. rF wrightsoft, Right -JCS Worksheet Entire House One Stop Cooling and Heating 7225 Sawsr-we Cox, Wirier Park, FL 32792 Phone: (407? 629 - 6920 Fax: (407) 629 - 9307 Web: wwwOneStop(,00lir)g.com Ucense: CAC032444 Job: Lot 034 Sundance A LHG - N Date: 02/27/2018 By: LF/RI/MC/AT/MC I Room name POW VIBED 2 E)posed vqell 3.5 it 27.0 If 3 Room height 9.3 ft heat/cool 9,0 ft heat(cool 4 Room dimensions 7.5 x 3.5 It 14.5 x 12.5 It 5 Room area 263 ft' 181.3 W Ty Construction number U-Value Btuwfl Or HTM Btu Area (ft) or perimeter (ft) Load B h) Area (In or perimeter (ft) Load Bruh) Heat Cool Gross N/PiS Heat Cool Gross N/P/S Heat Cool 6 yJ 126-09w 0.097 n 2.53 2.82 0 0 0 0 113 113 285 317 4B5-2ftn 0.540 n 14.09 13.67 0 0 0 0 0 0 0 0 t--G 13A-flocs 0.143 n 3.73 2.90 0 0 0 0 0 0 0 0 465-2(m O.W n 14,09 13.67 0 0 0 0 0 0 0 0 11 126-0sw 0.097 e 253 2.82 0 0 0 0 0 0 0 0 4A5-2orn 0.550 e 14 35 27.44 0 0 0 0 0 0 0 0 t-D I 3A-4ocs 0.143 e 3.73 2.90 0 0 0 0 0 0 0 0 11 DO 0.390 e 10.18 12.27 0 0 0 0 0 0 0 0 1213-09N 0.097 a 2.53 2.82 0 0 0 0 0 0 0 0 T:f2 4A5-2om 0.550 s 1435 13.54 0 0 0 0 0 0 0 0 485-2frn 0.540 s 14,09 13.67 0 0 0 0 0 0 0 0 w 13A-4ocs 0,143 s 3,73 2.90 33 33 121 94 0 0 0 0 t---G 12B-09N 0.097 w 2,53 Z82 0 0 0 0 131 101 254 283 4A5-tom 13A-4ocs 0,550 0.143 w w 1435 3,73 27.44 2.90 0 0 0 0 0 0 0 0 30 0 0 0 431 0 823 0 T:f2 4A5-2om 0.550 w 14.35 27.44 0 0 0 0 0 0 0 0 4A5-2omd 0.580 w 15.14 21.44 0 0 0 0 0 0 0 0 P L--D 12C-0sw 0.091 L38 ILI 33 33 77 49 0 0 0 0 11 DO 0.390 n 10.18 1227 0 0 0 0 0 0 0 0 C 1613-30ad 0.032 024 1.76 0 0 0 0 181 181 151 319 F 1 9A-Obs(p 0295 2.89 2-04 0 0 0 0 a 0 0 0 F 19C-19= 0.049 0.44 0,31 0 0 0 0 0 0 0 0 F 22A-Ipm 1.180 30.80 0.00 26 4 108 0 0 0 0 0 6 c) AED excursion 61 255 Envelope loss/gain 307 137 1121 1997 12 a) Infiltration 61 22 457 167 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 2 460 Appliancievother 0 01 Subtotal (lines 6 to 13) 1 368 159 1578 2625 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 273 249 14 Subtotal 368 159 1851 2874 Duct loads 14% 43% 52 69 13] 33/. 240 939 r15 Total room load 420 228 2091 3813 Air required (cfm) 0 11 0 179 4- Calculations approved byACCAto meet all requirements of Manual J 8th Ed. 2018-Feb-27 14:02 h0 Right-SuteS U"versal 201,8 18.0,11 RSU25029 Page 4 ante A LHG - MLot 034 Su -came A LHG - N.rT Cale- W8 House faces: N di- rF wrightsoft' Right-J@ Worksheet Entire House One Stop Cooling and Heating 7225 Sardscove Cow- W inter Park, FL 32792 P I ore: (407) 629 - 6920 Fax (407)629-9307 Web: mkwOneSlopCoolirg.com License: CAGO32444 Job: Lot 034 Sundance A LHG - IN Date: 02/27'2018 By. LF/RI MCATIMC 1 Room name MWIC MTOI 2 Exposed wall 8.5 ft 11.0 It 3 Room height 9,0 If heat/cool 9.0 If heat/cool 4 Room dimensions 10 x 54.8 it 7.0 x 4.0 ft 5 Room area 54.8 It' 28.0 flF Ty Construction Ll-value or HTM Area (fly) Load Area (ft) Load number BtuhMQ-+ B I or perimeter (ft) h) I or perimeter (ft) Btuh) Heat Cool Gross N/P/S Heat cod Gross N/FS Heat Cool 6 yJ 12B-0sw 0.097 n 2.53 2.82 0 0 0 0 0 0 0 0 4B5-2(m 0,540 n 14,09 13,67 0 0 0 0 0 0 0 0 t-G 13A-flocs 0.143 n 3.73 2.90 0 0 0 0 0 0 0 0 4B5-2fm 0,540 n 14,09 13.67 0 0 0 0 0 0 0 0 W11 126-0sN 0,097 e 2,53 2.82 0 0 0 0 0 0 0 0 4A5-2om OL50 e 14,35 27,44 0 0 0 0 0 0 0 0 3A-flocs111DO 0*143 e 3.73 2,90 0 0 0 0 0 0 0 0 T-D 0390 e 10.18 12,27 0 0 0 0 0 0 0 0 12B-OS6V 0.097 s 2 -53 2.62 0 0 0 0 36 36 91 101 4A5-2om 0550 S 14.35 13.54 0 0 0 0 0 0 0 0 4B5-2tm 0.540 s 14.09 13.67 0 a 0 0 0 0 0 0 W 13A-flocs 0.143 s 333 2.90 0 0 0 0 0 0 0 0 128-0,9N 0,097 w 2.53 2.82 77 77 194 216 63 63 159 178 4A5-2om 0,550 w 1435 27.44 0 0 0 0 0 0 0 0 13A-4ocs 0.143 w 3.73 2.90 0 0 0 0 0 0 0 0 4A5-tom 0,550 w 14.35 2744 0 0 0 0 0 0 0 0 4A5-2omd 0.580 w 15.14 2144 0 0 0 0 0 0 0 0 1 2C-0sw 0.091 Z38 151 0 0 0 0 0 0 0 0 11DO 0.390 n 10,18 12.27 0 0 0 0 0 0 0 0 C 16B-30ad 0.032 0.84 1.76 55 55 46 96 28 28 23 49 F 19A-ft. 0295 2,89 2.04 42 42 121 85 28 28 81 57 F 19---19= 0.049 0.44 031 0 0 0 0 0 0 0 0 F 22A-tprn 1.180 30.80 0.00 0 0 0 0 0 0 0 0 6 c) AED excursion 171 17 Envelope IoWgain 360 w 355 368 12 a) Infiltration 144 53 186 68 b) Room ventilation 1 0 0 1 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Applianoes/other 0 0 Subtotal (lines 6 to 13) 5041 433 541 436 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 504 433 541 436 15 Dud loads 1 13% 33% 65 141 13%1 33% 1 70 143 Tonal room load 569 574 611 579 Air squired (dm) of Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 42018-Feb-27 14 02,40 Right- Sute,6 Universal 2018 18,0,11 RSU25029 Page 5 arm A LHG 034 Sunciance A LHG - N.rup Calc = MJ8 House faces: N wrightsoft, Right-JO Worksheet Entire House One Stop Cooling and Heating 7225 Sardscove Cour, Winter Park, FL 32792 Plnre: (407r 629 - 6920 Fax: (407) 629 - 9307 Web: wwwOreStopCooling.corri License: CAC032444 Job: Lot 034 Sundance A LHG - N Date: 02/27/2018 B)r. LF/RUMCAT/MiC 1 Room name METH BED4 2 Exposed wall 6.0 it 115 ft 3 Room height 9.0 ft heat/cool 9,0 ft heaV000l 4 Room dimensions l'O x 915 It 1.0 x 128.9 It 5 Room area 93.5 ft2 128.9 it' Ty Construction number U-value Btuft4VLF) r HTM B 2) Area (It) or perimeter (ft) Load Btuh) Area (111) or perimeter (it) Load Btuh) Heat Cool Gross NiP/S Heat Cool Gross N/P/S Heat Cool 6 t 12B-09N 0,097 n Z53 2.82 0 0 0 0 0 0 0 0 465-2im 0,540 n 14,09 13.67 0 0 0 0 0 0 0 0G t-G 13A-flocs 0.143 n 3.73 2.90 0 0 0 0 0 0 0 0 485-2frn 0-540 n 14.09 13.67 0 0 0 0 0 0 0 0 V11 12B-Osw 0.097 e 2,53 282 0 0 0 0 0 0 0 0 4A5-2om OL50 e 14.35 2744 0 0 0 0 0 0 0 0 VVal 13A-4o c' 0,143 e 3.73 2.90 0 0 0 0 0 0 0 0 11 DO 0,390 e 10.18 1227 0 0 0 0 0 0 0 0 T:f2 126-Osw 4A.5-2om 0.097 0550 s s 2.53 1435 2,82 1354 54 0 50 0 127 0 141 0 122 15 107 13 270 215 300 203 4135-21m 0.540 s 14.09 1167 4 4 56 55 0 0 0 0 w 13A-4ocs 0.143 s 3.73 2.90 0 0 0 0 0 0 0 0 t--G 12B-09N 0,097 w 2M Z82 0 0 0 0 0 0 0 0 4A5-tom 13A-4ocs 0,550 0.143 w w 14,35 3.73 27.44 2.90 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 4A5-tom 0,550 w 14,35 27,44 0 0 0 0 0 0 0 0 P L--D 4A5-2omd 12C-Osw 0580 U91 w 15,14 Z38 21. 44 141 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 11DO 0.390 in 10.18 1227 0 0 0 0 0 0 0 0 C 11613-30ad 0.032 0.84 1.76 94 94 78 164 129 129 108 227 F 1 9A-Obs(p 0295 239 2.04 38 38 ill 78 0 0 0 0 F 19C-19= 0.049 0.44 031 0 0 0 0 0 0 0 0 F 22A-tpm 1,180 30,80 0.00 0 a 0 0 0 0 0 0 6 c) AED excursion 18 29 Envelope IoWgain 372 420 593 701 12 a) Infiltration 101 37 228 84 b) Room ventilation 0 0 Ol 0 13 Internal gains: 0ocupants @ 230 0 0 0 0 Appltancesrbther 0 0 Subtotal ( lines 6 to 13) 473 457 821 784 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 7 14 19 39 14 Subtotal 480 471 840 823 1151 Dud loads 1 13% 33] 62 114 13%1 331] 109 269 Total room load 542 625 949 1092 Air required (Cfm) 0 29 0 51 Calculations aggroved byACCA to meet all requirements of Manual J 8th Ed. 2018- Feb-27 14:02.40 Right- Suteft Uriversal 20 1, 8 18.0.11 RSU25029 Page 6 ante A LHG - M-ot 034 Sundarce A LHG - N,rup Gaic = W8 House faces: N d IF wrightsoft, Right -JCS Worksheet Entire House One Stop Cooling and Heating 7225 Sardsrmve Court, Wirter Park, FL 32792 Phare: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: www0neStopCoahng.corn License: CAC032444 Job: Lot 034 Sundance A LH G - N Date: 02/27/2018 By: LF/RI/MC/AT/MC 1 Room name STH LDRY 2 Exposed well 0 If 0 If 3 Room height 9.0 It heat(cool 9.0 It heat/cool 4 Room dimensions S x 10.0 it 6.5 x 63 It 5 Room area 55.0 f12 42.3 IF Ty Construction U-value Or HTM Area M Load Area M) Load number Btuw-,q Btu or perimeter (ft) 6tuh) or perimeter (ft) Btuh) Heat Cool Gross N/P/S Heat cool Gross N/RS Heat Cool 6 yt 12B-Osw 0.097 n 2.53 2.82 0 0 0 0 0 0 0 0 4135-2frn 0.540 n 14,09 13.67 0 0 0 0 0 0 0 0 VIt 13A-flocs 0,143 n 3,73 2.90 0 0 0 0 0 0 0 0 4B5-2fm 0.540 n 14.09 13.67 0 0 0 0 0 0 0 0 1 12B-Osw 0.097 e 2,53 2.82 0 0 0 0 0 0 0 0 4A5-tom 0.550 e 14,35 2744 0 0 0 0 0 0 0 0 t-D 13A-4= 1 1DO 0.143 0.390 e e 3.73 10.18 2.90 12.27 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 T:::G 12(3-0sm 4A5-tom 0,097 0.550 s s 2.53 14.35 2.82 1354 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 4B5-2fM 0.540 s 14.09 13.67 0 0 0 0 0 0 0 0 W 13A-flocs 0.143 s 3.73 2,90 0 0 0 0 0 0 0 0 t--G 1213-0sw 0,097 w 2.53 Z82 0 0 0 0 0 0 0 0 4A5-2om 13A-4ocs 0550 0.143 w w 1435 3,73 27.44 2,90 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 4A5-2om 05W w 14.35 27.44 0 0 0 0 0 0 0 0 RPI 4A5-2omd 12C-Osw 0.580 U91 w 15.14 2.38 21.44 Isi 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 11DO 0390 n 10.18 12,27 0 0 0 0 0 0 0 0 C 16B-30ad 0.032 0.84 136 55 55 46 97 42 42 35 74 F 19A-,Obscp 0295 2.89 Z04 0 0 0 0 0 0 0 0 F 19c-19cscp 0.049 0." 0.31 0 0 0 0 0 0 0 0 F 22A-!pm 1.180 30.80 0.00 0 0 0 0 0 0 0 0 6 c) AED excursion 4 22 Envelope Iossgain 46 93 35 53 12 a) Infiltration 0 0 0 0 b) Room ventilation 0 0 of 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 500 Subtotal (lines 6 to 13) 46 931 35 553 Less e)demal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 26 52 437 390 14 Subtotal 72 145 472 943 15 Duct loads 13% 33% 9 47 13% 33% 61 3081 Total room load 81 t 93 533 1251 Air required (cl1m) I 1 01 0 59 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2018-Feb-27 14:02,40 Righ(-Sute8 Uriversal 2018 18.0. 11 RSU25029 Page 7 arse A LHG - MLot 034 SLMarre A LHG - N.rup Calc - MJ8 House faces: N wrightsoft, Right-J@ Worksheet Entire House One Stop Cooling and Heating 7225 Sandscove Cart, Winter Park, FL32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: wAm.0neStopCoolirg,com License: CAC032444 Job: Lot 034 Suridance A LHG - N Date: 02/27/2018 By. LF/RI/MC/AT/MC I Room name STR2 2 Exposed wall 22.5 If 0 It 3 Room height 9.0 ft heat/bool 9.0 It heaV000l 4 Room dimensions 4.0 x 18.5 It 6.5 x 3.5 If 5 Room area 74.0 W 22.8 ft' Ty Construction number U-value Btuw1q Or HTM Btuh/fr) Area OF) or perimeter (ft) Load Btuh) Area M) or perimeter (ft) Load Bbih) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat cool 6 kt 12B-0sw 0.097 n 2.53 2.82 167 163 411 458 0 0 0 0 41215-2m 0.540 n 14.09 13.67 4 0 56 55 0 0 0 0G t-4.- 13A-flocs 0.143 n 3.73 2.90 0 0 0 0 0 0 0 0 4135-21m 0.540 n 14.09 13.67 0 0 0 0 0 0 0 0 Y11 126-09N U97 e 2.53 282 36 36 91 101 0 0 0 0 4A5-2om 0.550 e 14,35 27.44 0 0 0 0 0 0 0 0 13A-4= 0.143 e 3.73 2.90 0 0 0 0 0 0 0 0 D 1 IDO 0.390 e 10.18 12.27 0 0 0 0 0 0 0 0 VjJ 1213-0sw 0,097 s 2.53 2.82 0 0 0 0 0 0 0 0 4A5-2om 0.550 s 14.35 13.54 0 0 0 0 0 0 0 0 4135-2fm 0.540 s 14.09 13.67 0 0 0 0 0 0 0 0 w 13A-flocs 0.143 s 3.73 2.90 0 0 0 0 0 0 0 0 t-G 1213-09M U97 w 2M 282 0 0 0 0 0 0 0 0 4A5-2om 13A-flocs 0650 0.143 w w 14.35 3.73 27.44 2.90 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 4A5-tom 0,550 w 1435 27.44 0 0 0 0 0 0 0 0 PL-D 4A5-2omd 12C-Osw 0.580 0.091 w 15.14 238 21.44 151 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 11DO 0.390 n 10.18 1227 0 0 0 0 0 0 0 0 C 1613-30ad 0.032 0.84 1.76 74 74 62 130 23 23 19 40 F 19A-Obscp 0295 2.89 204 0 0 0 0 0 0 0 0 F 19C-19cs(p 0.049 0.44 031 0 0 0 0 0 0 0 0 F 22A-tpm 1.180 30.80 0.00 0 0 0 0 0 0 0 0 6 c) AED excursion 331 1 -2 Envelope loss)qain 621 711 19 38 12 a) Infiltration 381 140 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: 0ocupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 1001 850 19 38 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 1001 850 19 38 14 Subtotal 0 0 0 0 15 Duct loads 13% 33% 0 0 13% 33/.l 01 0 Total room load 0 0 0 0 Air required (dm) 0 0 01 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2018-Feb-27 14:02:40 Right-SuteS Uriversal 2018 18,0.11 RSU25029 Page 8 arre A LHG - N'Lot 034 Surdance A LHG - N.rup Calc = W8 House faces: N IL rF wrightsoft, Right-JO Worksheet Entire House One Stop Cooling and Heating 7225 SandscoveCourt, WirAer Park, FL,32792 PN)re:(407) 629-6920 Fax: (407)629-9307 Web: w'Aw0neStopGooIirk3.wrn License: CAC032444 Job: Lot 034 Sundance A LHG - N Date: 02/27/2018 By. LFRUMCIAPIVIC 1 Room name WIC2 BED2 2 Exposed wall 5.0 It 16.0 R 3 Room height 9.0 It heat/cool 9-0 It heat/cool 4 Room dimensions 5.0 x 5.0 It 10.5 x 10.5 It 5 Room area 25.0 R2 110.3 If? Ty Construction number U- value Btuhff-+ F Or HTIVI 810412) Area ( ft or perimeter (ft) Load Btuh) Area ( ft) or perimeter (ft) Load Btuh) Heat Cool Gross N/P/S Heat Cool Gross N(P/S Heat cool 6 T---G 128- NN 485- 211m 13A- 4ocs 0. 097 0. 540 0, 143 n n n 2. 53 14, 09 3. 73 2. 82 13. 67 2. 90 0 0 0 0 0 0 0 0 0 0 0 0 50 0 0 50 0 0 125 0 0 139 0 0 11 485- 2trn 12B- Osw 0. 540 0, 097 n e 14. 09 2. 53 13. 67 2. 82 0 45 0 45 0 114 0 127 0 95 0 80 0 201 0 224 W4A5- 2om 3A- flocs 11 DO 0550 0. 143 0. 390 e e e 14, 35 3. 73 10. 18 27. 44 2. 90 12. 27 0 0 0 0 0 0 0 0 0 0 0 0 15 0 0 0 0 0 215 0 0 412 0 0 t-D T-- t 1213- 09.v 4A5- 2om 0. 097 0. 550 s s Z53 14. 35 2. 82 13. 54 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 W t-- G- 465- 2tm 13A- 4ocs 12B- Osw 0. 540 0, 143 0, 097 s s w 1449 3. 73 2. 53 13. 67 2. 90 2. 82 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 4A5- tom 13A- flocs 0. 550 0. 14.3 w w 1435 3. 73 27. 44 2. 90 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 4A5- tom 4A5- 2omd 12C- 09N 0. 550 0. 580 0. 091 w w 1435 1514 Z38 27. 44 21 A4 151 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 P11DO 1613- 30ad 0. 390 0. 032 n 10,18 0. 84 1227 1. 76 0 25 0 25 0 21 0 44 0 110 0 110 0 92 0 194 CF 1 9A-Obs(p 0295 2.89 2.04 0 0 0 0 0 0 0 0 F 19C-19csm 0.049 0.44 031 0 0 0 0 88 88 39 27 F 22A-tpm 1.180 30.80 0.00 0 0 0 0 0 0 0 0 6 c) AED excursion 81 28 Envelope loss -'gain 135 163 673 1024 12 a) Infiltration 85 31 271 99 b) Room ventilation 0 0 0 0 13 Internal gains: Omipants @ 230 0 0 1 230 Appliances/ other 0 0 Subtotal ( lines 6 to 13) 219 1941 944 1353 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 329 286 7 13 14 Subtotal 548 480 950 1367 15 Duct loads 13% 33% 71 157 131/ 33% 123 447 Toal room load 619 637 Air required(dm)1 01 30 1 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. H- 2018-Feb-27 14:0240 Righ- SuteOUniversaI2018 18.0.11 RSU25029 Page 9 ACZK ,,Zrr ' e A LHG - N\Lot 034 Surylance A LHG - N.rup Calc - W8 House faces: N AL- 77 wrightsoft* Right-JO Worksheet Entire House One Stop Cooling and Heating 7225 Sandscove Court, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: www.OrieStopCooling.com License: CAGO32444 Job: Lot 034 Sundance A LHG - N Date: 02/27/2018 By. LF/RI/MC/AT/MC 1 Room name BED3 HALL 2 Eposed wall 23.5 If 0 It 3 Room height 9.0 It heat/cool 9.0 It heat1bool 4 Room dimensions 1,0 x 127.8 ff ID x 102.1 If 5 Room area 127.8 ft2 102.1 ft2 Ty Construction number U-value Btu"-,i--) Or HTIM a /ft2) Area (ft2) or perimeter (Ift) Load 13tuh) Area (ft2) or perimeter (ft) Load Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 t--G 1 62 -Osw 0.097 n 2,53 2.82 0 0 0 0 0 0 0 0 4135-2fm 0,540 n 14.09 13.67 0 0 0 0 0 0 0 0 13A-flocs 0.143 n 3.73 2.90 0 0 0 0 0 0 0 0 4B5-2fm 0.540 n 14.09 13.67 0 0 0 0 0 0 0 0 t---.G 11 162 -Osw 0.097 e 2.53 2,82 95 80 201 224 0 0 0 0 4A5-2om 0.550 e 14.35 27.44 15 0 215 412 0 0 0 0 1 3A-4o 0.143 e 3.73 2.90 0 0 0 0 0 0 0 0t-D 11 DO 0,390 e 10.18 1227 0 0 0 0 0 0 0 0 128-Osw 4A5-tom 0.097 0.550 s S Z53 1435 2.82 13,54 117 0 117 0 296 0 330 0 0 0 0 0 0 0 0 0 465-2fm 0.540 s 14.09 13.67 0 0 0 0 0 0 0 0 W 13A-floes 0.143 s 3.73 2.90 0 0 0 0 0 0 0 0 T---G 12B-Osw 0.097 w 2-53 2.82 0 0 0 0 0 0 0 0 4A5-2om 13A-flocs 0,550 OA43 w w 14-15 333 27.44 2,90 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 4A5-2om 0550 w 14,35 27.44 0 0 0 0 0 0 0 0 R L--D 4A5-2omd 12C-Osw 0.580 0,091 w 15.14 2.38 21.44 izi 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 11DO 16B-30ad 0.390 0.032 n 10.18 0S4 12.27 1.76 0 128 0 128 0 107 0 225 0 102 0 102 0 85 0 180C F 19A-Obscp 0295 2,89 2.04 0 0 0 0 0 0 0 0 F lgc-lgcscp 0,049 0.44 031 102 102 45 32 0 0 0 0 F 22A-tpm 1.180 30.80 0.00 0 0 0 0 0 0 0 0 6 c) AED excursion 17 7 Envelope loss/gain 865 1239 85 173 12 a) Infiltration 397 146 0 0 b) Room ventilation 1 0 of 1 0 0 13 Internal gains: 0ocupants @ 230 1 230 0 0 Applianoesiother 0 0 Subtotal (lines 6 to 13) 1262 1615 85 173 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 8 1 85 173 14 Subtotal 1270 1632 0 0 15 Duct loads 131/. 33%1 165 533 13 %1 1 0 0 Total room load 14351 2165 1 0 0 Air required (cfm) 0 101 0 01 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2018-Feb-27 14:0240 Right-Sute6 Universal 2018 18.0.11 RSU25029 Page 10 ante A LHG - N\Lot 034 SLMance A LHG - N.r4p Calc = MJ8 House faces: N u mw unovn exuamStatic x Friction Rate Job: m 02127/2018 `- Entire House By: LFm|/Mc/AT/Mo One Stop Cooling and Heating 7225 Sandscove Court,Winter Park, FL32792 Phone: (407) 629 -6920 Fax:(407)629-9307 Web: wwwOneStopCooling.00m License: CA=2444 For: Park Square Homes 3808SakmamhLoop, Sanford, FL Heating Cooling inH2D) inH2O) External static pressure 0.50 0.50 Pressure losses OuU O O Heat exchanger O 0 Supp| ydi8baors 0.03 0.03 Return grilles 0.83 0.03 Filter 0.10 OJU Humidifier O O Balancing damper U O Other device 0 0 Available static pressure 0.34 0.34 Supply Return ft) ft) Measured length ofmn'out 16 0 Measured length of trunk 33 12 Equivalent length cdfittings 145 45 Total length 194 57 Total * 0ectivalength 250 Friction. Rate, Heating Cooling in11O0t) im1U0N Supply Ducts 0.138 UK 0.136 OK Return Ducts 0.136 OK 0.130 OK Supply 4X--35.11A=20.11G=5.11A=20.118--5.11M=2U.11(]--5.1A~35:Total EL=145 wrightsoft, ev`o+~b-u /4o2:4 nw au Ou^myuommu.xmauusocy p e, Duct System Summary Job: Lot 034 Sundance A LH G wrightsoft* Date: 02/27/2018 Entire House By. LFRUMCATMC One Stop Cooling and Heating 7225Sardscove Coot, Wirter Park, FL32792 Phone:(407) 629- 6920 Fax (407) 629 -9307 Web: ~u0neSIOPCO01ing.com License: CAC032444 For: Park Square Homes 3908 Saltmarsh Loop, Sanford, FL External static pressure Pressure losses Available static pressure Supply/ return available pressure Lowest friction rate Actual air flow Total effective length (TEL) Heating 0.50 in H2O 0.16 in H2O 0.34 in H2O 0.263 /0.077 in H2O 0.136 in/1 00ft 0 cfm 250 Cooling 0.50 in H2O 0.16 in H2O 0,34 in H2O 0.263 /0.077 in H2O 0.136 in/100ft 1160 cfm Name Design Btuh) Htg cfm) Clg cfm) Design FR Diam in) H x W in) Duct Matl Actual Ln (ft) Ftg.Eqv Ln (ft) Trunk BED2 c 1813 0 85 0.141 6,0 Ox 0 AFx 41.5 145.0 st4 BED3 c 2165 0 101 0150 7.0 Ox 0 AFx 34,8 140.0 st4 BED4 c 1092 0 51 0.175 6.0 Ox 0 AFx 25.0 125.0 st3 9TH c 193 0 9 0.176 4.0 OX0 AFx 29.0 120.0 st3 DIN c 4508 0 211 0.140 8.0 OX0 AFx 48.3 140,0 st2 GATH c 4478 0 210 0.146 8.0 OX0 AFx 39.8 140.0 st2 KIT c 2797 0 131 0.146 7.0 Ox 0 AFx 40.3 140.0 st2 LDRY c 1251 0 59 0.168 5.0 Ox 0 AFx 364 120.0 st3 MBED c 3813 0 179 0.163 8.0 OX0 AFx 36.7 125.0 st3 MSTH c 625 0 29 0.168 4.0 Ox 0 AFx 31.1 125.0 st3 MToI c 579 0 27 0.168 4,0 Ox 0 AFx 36.1 120.0 st3 MWIC c 574 0 27 0.168 4.O OX0 AFx 31.9 125.0 st3 POW c 228 0 11 0.148 4.0 Ox 0 AFx 42.3 135.0 st2 WIC2 c 637 0 30 0.136 4.0 Ox 0 AFx 48.6 145.0 st4 Trunk Htg Clg Design Veloc Diam H x W Duct Name Type cfm) cfm) FR fpm) in) in) Material Trunk st4 PeakAVF 0 216 0.136 490 9.0 0 x 0 VinIFIx st3 sti PeakAVF 0 1160 0.136 656 18.0 0 x 0 VinlFlx st2 PeakAVF 0 563 0,140 717 12.0 0 x 0 VinlFlx SO st3 PeakAVF 0 597 0.136 559 14.0 0 x 0 VinlFlx SO wrightsoft, 2018-Feb-27 14,,02:41 Rtgh-SuteOUnversaI2018 18,0.11 RSU25029 Page 1 AC ...ante A LHG - Nlot 034 SLMarre A LHG - Nnp Calc - MJ8 Horse faces: N Return Brand :11)etajUT Grille Htg CIg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in) Cfm) Cfm) ft) FR fpm) in) in) Opening (in) Mal Trunk rb2 OX0 0 236 50,3 0.153 534 9.0 Ox 0 AFx rt2 rbl OX0 0 924 56.8 0136 662 16.0 Ox 0 AFx rt2 Name Trunk Type Htg Cfm) CIg Cfm) Design FIR Veloc fpm) Diam in) H x W in) Duct Material Trunk rt2 PeakAVF 0 1160 0.136 656 18.0 0 x 0 VinIFIx wrightsoft* Rigll-SuteO lj"versal 20 ! 8 18.0.11 RSU25029 ace A LHG - N\Lot 034 Surdarce A LHG - N.rup Calc = MJ8 House faces N 2018-Feb-27 14:02:41 Page 2 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: Lot 034 Sundance A LHG - N Builder Name: Street: 3908 Saltmarsh Loop Permit Office ' City of Sanford City, State, Zip: Sanford , FL , Permit Number: Owner: Park Square Homes Jurisdiction: 691500 Design Location: FL, Orlando COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. requirements Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity with sealed. a material having a thermal resistance of R-3 per inch Knee walls shall be sealed. minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/door jambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls. Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity Garage separation Air sealing shall be provided between the garage and conditioned spac 9s. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in extedor walls, or insulation that on installation readily conforms to available space shall Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs, be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids a. In addition, inspection of log walls shall be in accordance with the provisions, of ICC-400. I ER V E Job#: Lot 034 Sundance A LHG - N Performed by LFRUMCAT for: Park Square Homes One Stop Cooling and Heating 7225 Sandscove Court Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 www.0neStopCbohg,com Scale: 1 :57 Page 1 Comfort Builder by Wrightsolt 18.0.07 RSU30040 2018,1an-30 10:44:45 Sundance\SundanceALFG -M.rup EF1 VTR EF1 VTR BEN 71106/" 9 51 cfm 1 OX6 10110 we Level 2 10X10 X4 179 cfm cfM 4" 1 OX1 0 RA 236 cfrn UT '9 HALL 24X1 8 RA 8X4 1 nYR 924 cfm 9 cfm 59 cfm 1811 tow- EF1 VTR LDRY 14 STR2 tUPPLY FLEX DIRECT F; VA 1=1 TOAHU 12" T- 14 85 cfm 10x10 1 OX6 EF1 = 50 CFM Fan EF2 = 80 CFM Fan EF3 = 110 CFM Fan EFL1 = 50 CFM Fan EFI-2 = 80 CFM Fan EFL3 = 110 CFM Fan VTR = Vent to Roof VTW = Vent to Wall DV = Dryer Vent RV = Range Vent Lineset Chase Condensate Thermostat 18/8 SRB = Small Reduction Box LRB = Large Reduction Box FBB = Field Built Box Job #: Lot 034 Sundance A LHG - N Performed by LF/RI/MC/AT for: Park Square Homes Sanford, FL Sup R WIC2 12 30 cfm 8X4 Zone Damper 1 - 12" Zone Damper 2 - 12" Bypass Damper - 10" One Stop Cooling and Heating 7225 Sandscove Court Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 www.0neStopCbo1hg,com Scale: 1 :57 Page 2 Comfort: Builder by W rightsoft 18.0.07 RSLJ30040 2018.\Jan-30 10:44:45 Sundance\Sundance A LHG - M.rup fol C rO Z 7?9 LV Wt(- KI RFC01,1 D DESCRIPTION AS FURNISHED: Lot 34, WYNDHAM PRESERVE, as recorded in Plot Book 81, Pages 93 through 102 of the Public Records of Seminole County, Florida. PLOT PLAN FOR/CERTIFIED TO: Park Square Enterprises, LLC (a Delaware Corporation); Winderweedle, Haines, Word & Woodman, PA; Attorneys' Title Insurance Fund; Bank of America LOT 49 LOT 50 AT 181904051" E 4O. 00 43. 1 X 43. IJ' I LOT 34 1 Ok to construct single family home with setbacks and impervious area shown on plan. 39. S -t,,, k-13() A, 6rL 16.7- LANAI o 300.0' r14 AC 13.3' ar, LOT 35 -P C LOT 33 PROPOSED RESIDENCE 1730 SUNDANCE - A CT 2 CAR GARAGE LEFT COV'D. CQ ENTRY 9.0' 5.00' SETBACKS AS FURNISHED FRONT - 25 REAR 20' SIDE 5' (40' LOT) 7.5' (60' LOT) 10 - (75' LOT) SIDE STREET = 25' (60' & 75' LOT) 15' (40' LOT) 25' FRONT SETBACK CAN BE REDUCED TO 20' ON CERTAIN LOTS, NO MORE THAN 2) IN SUCCESSION AT 20' AND A MINIMUM OF (2) IN SUCCESSION AT 25' PROPOSED = FINSHED SPOT GRADE ELEVATIONS PER DRAINAGE PIAKIC 5.00' 1 I V DRIVE - WALKj 42.8 7' 10' UTIL ESMT P.G. WALK V N 89040'51 " E 40. 00' SALTMARKS-z-7 LOOP PRIVATE ROAD (50' RIW) PLOT PLAN AREA CALCULATIONS r PROPOSED DRAINAGE FLOW LOT GRADING TYPE A PROPOSED F.F. PER PLANS = 30.5' QQ PLOT PLAN ONLY NOT A SURVEY IUIAL LUI AHA 4,6410 ± SQUARE FEET FLATWORK ON/OFF LOT = TOTAL t SQUARE FEET FLATWORK DRIVE 4031110- 513 t SQUARE FEET FOUNDATION/PAD 1,195 1 SQUARE FEET WALKS 721 200= 272 ± SQUARE FEET REAR PATIO 107 _+ SQUARE FEET Soo 2,8451 1JO = 2,975 1 SQUARE FEET FRONT PORCH DECK 48,* SQUARE FEET POOL DECK NIA + SQUARE FEET ONOTE., FRONT SIDEWALK AND STREET LOCATION TAKEN FROM PLANS PROVIDED BY CLIENT I NOT FIELD YER(FICO CRUSENHE_rER - SCOTT & ASSOC, 1.1VC - LA-IVD SURVE)IURS I LEGCHD - LCGEND - P PLAT PJDI_ POINT 00 LINE F FIELD TYP. m TYPICAL I.P. 2N PIPE PRz POINT or RCvcRUS.IT, I.R.ON C, ROD CONCRETE MONUMENT PJCIC. RAO. POINTOF COPPI =TIRC RADIAL SET LR, Ila' 10L •/NLJI 4396 N.R. NON -RADIAL RE. RCCOVCRCD wp WITNESS P4 C01POINTOFBEGINNINGGALLCALCULATEDIRTP.a, c, m POINT OF COUNCHCEHENT P.Rn PERMANENT REFERENCE MONUMENT i CENTERLINC rx , FINISHED FLOW ELEVATION NLO MAIL & DISK 0,SL BUILDING SCT8ACK LINE R,w R tCHT-CF-WAY SR RERCHHW CSHt m EASEMENT D.B. DASE WARINO DRAIN. DRAINAGE UTIL. UTILITY CLFC, WD. FCaCHAIN LINK FENCE WOOD FENCEC/o CONCRETE BLOCK P.E. POINT Of CURVATURE P.T. POINT OF TANGCKY DESC. DESCRIPTION A RADIUS L a ARC LENGTH D C DELTACHURO C.D. CHORD OCARING NORTH THIS BUILDING\ PROPERTY DOES NOT UE WITHIN THE ESTABLISHED 100 YEAR FLOOD PLANE AS PER 'nR&4' ZONE 1XI MAP I 12117COOPO r (09-28-07) 5400 E. COLONIAL DR. ORLANDO, FL. 32507 (407)-277-3232 FAX (407)-658- 1436 NOTES. I. THE uxomawo oors HEREBY CERTIFY THAT THIS SURVEY MEETS ME STANDARDS OF PRACTICE SET FORTH By THE FIoR(DA BOARD Or PROFESSIONAL SURVEYORS AND MAPPERS IN CHAPTER $J—?7 FLORIDA ADMINISTRAnVE CODE PURSUANT TO SECT70N 472,027, FLORIDA STArurS 2. UNLESS EMBOSSED WITH SURVEYORS SIONATuRr AND ORIGINAL RAISED SEAL. THIS SURVEY MAP OR COPIES ARE NOT VALID, 3. THIS SURVEY WAS PACPARED, FROM TITLE INFOR14ATION FURNISHED TO THE SURVEYOR. THERE MAY BE OTHER RESTRICTIONS OR CASEM& M THAT AFFECT THIS PROPERTY, 4. NO UNDERGROUND IWPROVEVEM HAVE BEEN LOCATED UNLESS OTHERWISE SHOWN, S, THIS SURVEY 15 PREPARED MR THE sote BENEFIT OF IN= CERTIFIED TO AND SHOULD HOF OC REM UPON BY ANY OTHER ENTITY, 0, 0114FNMONS SHOWN FOR THE LOC417ON OF IMPROVEMENTS HEREON SHOULD NOT Or USED TO RECONSTRUCT BOUNDARY LINES, 7 BEARINGS, ARE RASED ASSUMED DATUM AND ON THE LINE SHOWN AS WE 8FARWO (RO) B. ELEVAMIS, IF SHOW ARE BASED ON NATIONAL GrOOM VERTICAL DATUM OF 029, UNLESS OTHERWISE NOTED, B. CERTIFICATE OF AUTHORIZATION No, 4SP0. I SCALE I— I' - 20 1 DRAWN BY, ^" I I CERTIFIED BY. ORDER Na. PLOT PLAN 02-23-2010 1098-18 REVISED PLOT PLAN (GRADES) OJ-27-2018 TOM X. GRUSENMErER P.L. C147114-11 COrr, JAMES W. S R,,I, S 111 4 Filename: PARK SQUARE 8ORRENZO 2 U78SF RL[OKD[OYY LiBbting and Small Appliance/Laundry Circuits Floor Area Sm&pp0o LaundNo Line Neutral i 2 2 I Lighting Summary Standard 3,527 3,527 Optional 4,506 3,527 IlanBeo & Ovens Range No. 0o? Nameplate Line Neutral I I 8000 3 0 0 3 0 U Range/Oven Summary Standard 6,400 4,480 Optional 8,000 4,480 Dr3/era Dryer No. No? Nameplate Line Neutral I l 5000 -- 2 O - -- 3 O # Dryer Summary Standard 5,000 3,500 Optional 5,000 3,500 Heatiog and Cooling' Actual Number 2 Name M? Pb No Amps Volts VA BP Line Neutral 1 M l I 14.0 240 3,360 O I M l l 2.0 240 480 0 l M I I 5.0 240 1,200 0 I l I I 14 240 I 3,360 0 M I I I4.0 240 3,350 U 2 M I I 2.0 240 480 0 2 M, I l 5.0 240 1,208 0 2 l l I 14 240 I 3,360 0 Beat/Cool 8ommazl/ Standard 16,800 0 Optional I6,800 0 pixed Appliances: Actual Number = 6 Name M? Ph No Amps Volts VA HP Line Neutral DISP l I 120 600 6U0 600 DISH I I 120 I200 1,200 1,200 MZC}lD I I 120 I200 1,200 1,200 WB I I 18.5 240 4,440 0 DBI POOL, I I 10 240 2,400 O OPT POOL HEAT I l 31 240 7,440 0 Fixed Appliance Summary Standard I2,960 2,250 Optional 17,280 2,250 other Appliances: ActualNumber = O Name y4? b o n Volts B Line Neutral Other Appliance Summary Standard 0 0 Optional 0 0 25% of Max Motor: Line is Std Only; Neutral for Both Maximum Phase Amps Volts 14 240 Heat/Cool Phase Amps Volts 1 14 240 Fixed Appl. Phase Amps Volts 0 Other Appl. Phase Amps Volts 0 Max Motor Summary Standard Only 840 0 SUMMARY Standard Line Neutral Total Total - 45,527 13,757 Maximum Amperage = 190 57 Service Voltage = 240 Service Phase = 1 Optional Line Neutral Total Total - 36,71413,757 Maximum Amperage = 153 57 Service Voltage = 240 Service Phase = 1 Lumber design values are inaccordance with ANS|/TP|1section G.3 These truss designs rely on lumber values established by others. RE: P173OA- Park 6o 8undonm+1730-A MiTekUSA, Inc. Pa Eu 0vd Site Information: 8 ' Tu Q40,4J 5 Customer Info: PARK S{lUAREHD/ES Project Name: P173UA/NOOPT Model: uumD qCE/uu-A Lot/Block: 34 Subdivision: VVYNOHAK4PRESERVE 4O Address: 3S0OGALTK4ARSHLOOP City: SANFORD State: FLORIDA Name Address and License # of Structural Engineer of Record, If there is one, for the building. Name: License #: Address: City.. State: General Truss Engineering O Loads (individual Truss Design Drawings Show Special Loading Conditions): Design Code: BC207/TP| Design K4i7ck20/208.i Wind Code: ASC87-|0 Wind Speed: 140mph Roof Load: 40.0psf Floor Load: 55/3ps/ This package includes 36 individual, dated Truss Design Drawings and 0 Additional Drawings. With myseal affixed hothis sheet, | hereby certify that |amthe Truss Design Engineer and this index sheet conforms to 61 G1 5-31.003, section 5 of the Florida Board of Professional Engineers Rules. This item has been electronically signed andoealed by Albani, Thomas, PEusing aDigital Printed copies ufthis document are not considered signed and sealed and the signature must be verified on any electronic copies u 4- x The truss druwing(s) ro[6rcncodabove havebeenprepared hyK4iTck USA, Inc. under mydirect supervision based onthe parameters provided hyMid- Florida Lum6crAcquisitions, Inc.. Truss Design Engineer's Name: A|bani. Thonoaa Mylicense renewal date for the state o[Florida io February 28,20l9. IMPORTANT NOTE: The seal on these truss component designs is a certification that the engineer named is licensed in the jurisdiction(s) identified and that the designs comply with ANSIITPI 1. These designs are based upon parameters shown (e.g., loads, supports, dimensions, shapes and design codes), which were given to MiTek. Any project specific information included is for MiTek's customers file reference purpose only, and was not taken into account in the preparation of these designs. MiTek has not independently verified the applicability of the design parameters or the designs for any particular building. Before use, the building designer should verify applicability of design parameters and property incorporate these designs into the overall building design per ANSIfTPI 1, Chapter 2. Fcbruary2320|8 lbuoi,T6omuu | of RE: P1730A -Park Sq/Sundance-1730-A Site Information: Cuabome/|nfo PARKSOUAREHOMES : P1730A/NODPT Mode: SUNOANCE1730-A Lot/Block: 34 Subdivision: VVYN[}HANPRESERVE 4O Address: 39O8SALTK8ARGHLOOP Job _ W Truss Truss Type m Qty Ply Park Sq! Sundance-1730-A T73325036 P1130A W _ At COMMON I2 Tmm 1 gC P.S&10 tin Mid -Florida Lumber, Bartow, FL. 8.130 s Sep 15 2017 MiTek Industries, Inc. Fri Feb 23 13:14:10 2018 Page 1 ID:3zzrE5595gHBgKdROwR6OYzkwee-1 jd9E36s3A8cyZtbS68TFE 1808ufXL3n8LMj6EziF5x 14).0 7-11-11 15-0-0 22-0-5 30-0-0 1.OA 7-ii-tt 7-0.5 7.0-5 7-11-11 tA-0 Scale = 1 53.5 4x4 it 4x4 = 4 3x4 = 3x4 = 3x4 = 4x4 = LOADING (psf) SPACING- 2-0-0 CSL DEFL. in loc) I/dell L/d TCLL 20.0 Plate Grip DOL 1_25 TC 0.74 Vert(LL) 0.40 8-10 905 240 TCDL 10.0 Lumber DOL 1.25 BC 0.75 Vert(CT) 0.55 8-10 651 180 BCLL 0.0 Rep Stress Incr YES WS 0.51 Horz(CT) 0.06 6 rite n/a BCDL 10.0 Code FBC2017/TPI2014 Matrix -MS LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.t WEBS 2x4 SP No.3 REACTIONS. (lb/size) 2=1260/0-8-0, 6=1260/0-3-8 Max Horz 2=155(LC 12) Max Uplift 2=396(LC 12), 6=-396(LC 13) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown, TOP CHORD 2-3=-2101/623, 3-4=-1914/644, 4-5=19141644, 5-6=-2101/623 BOT CHORD 2-10=594/1826, 8-10=-254/1198, 6-8- 455/1826 WEBS 4-8=319/776, 5-8=-465/352, 4-10=3191776, 3- 1 0=-465/352 PLATES GRIP MT20 2441190 Weight: 137 lb FT = 20 BRACING - TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 7-10-7 oc bracing. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10, Vutt=140mph (3-second gust) Vasd=108mph; TCDL=4.2psf; BCDL=3,Opsf, h=25ft; Cat. 11; Exp B; Encl., GCpi=0.18; MWFRS (envelope) gable end zone and C-C Exterior(2) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 15-0-0, Exterior(2) 15-0-0 to 18-0-0 zone,C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) " This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 1 O.Opsf. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb) 2=396, 6=-396. This item has been electronically signed and sealed by Albani, Thomas, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on,pny lectronip copies. IIThomas A 41b&ni PE-Eo-393 0 MI[ekUSA IrtcCert66 8904 Park Ea Ii L 336tA February 23,2018 WARNING - Vorify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 11,1I1-7473 rev. I"V2015 BEFORE USE. Design valid for use only with MtT" connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing Rawisalwaysrequiredforstabilityandtopreventcollapsewithpossiblepersonalinjuryandpropertydamage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITPII Quality Criteria, DS8-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 lilo" TrussiTlTruss TA'2 rruss Type iPly Pa Sq/ Sundance-1730-A r2 T13325037 t iqnJgpilly Mid-Flonda Lumber, Barlow, FL. 8,130 s Sep 15 2017 MiTek Industries. Inc. Fri Feb 23 13:14:11 2018 Page I ID:3zzrE5595qHBqKdROwR6OYzkwee-V\iAXSP7UqUGTZjSnOpfinSaNsXFKG16wM?6GfgziF5w 1-0-0 6-9-4 13-0-0 17-0-0 23-2-12 30-0-0 Z 1 6-9-A 4212 212 1:6:67 Scale = 1 52.1 4x8 5 4x4 I 13 - 11 10 9 4x4 1.5X4 11 3x4 = 3x8 = 1,5X4 11 4x4 3x4 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) Ildef! L/d PLATES GRIP TCLL 20,0 Plate Grip DOL 1.25 TC 0.50 Vert(I-L) -0.10 11 >999 240 MT20 2441190 TCDIL 10.0 Lumber DOL 1.25 BC 0.66 Vert(CT) -0.21 11-13 >999 180 BCLL 0,0 Rep Stress Incr YES WB 0.65 Horz(CT) -0,09 2 n1a n/a BCDL 10,0 Code FBC2017frPI2014 Matrix -MS Weight: 157 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 3-5-13 oc purlins. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 7-6-10 oc bracing. WEBS 2x4 SP No.3 REACTIONS. (lb/size) 7=1260/0-3-8,2=1260/0-8-0 Max Horz 7=136(1-C 13) Max Uplift 7=-380(LC 13),2=380(1-C 12) FORCES. (lb) - Max, Comp./Max, Ten, - All forces 250 (lb) or less except when shown. TOP CHORD 5-6-1611/587, 6-7--2223/709,4-5=-1363/585,2-3=22231709, 3-4=-1610/587 BOT CHORD 2-13=-55211926, 11-13=-552/1926, 10-11=-31111362, 9-10=-579/1925,7-9--579/1925 WEBS 6-9= 01287,6-10--6511349,5-10=-119/420, 4-11=-132/419,3-11=-652/350.3-13=0/288 NOTES- 1) Unbalanced roof live loads have been considered for this design, 2) Wind: ASCE 7- 10: Vult=140mph (3-second gust) Vasd-108mph; TCDL-4.2psf; BCDL=3.Opsf ' h=25ft; Cat. 11 Exp 8; Encl., GCpi=0,18, MWFRS ( envelope) gable end zone and C-C Exterior(2) -1-0-0 to 2-0-0, Intenor(l) 2-0-0 to 1340 0, Extenor(2) 13-0-0 to 17-0-0, Interior( l) 21-2-15 to 31-0-0 zone,C-C for members and forces & MViJFRS for reactions shown, Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water pending. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads, 5) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection ( by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Ot=lb) 7=380,2-380. This item has been electronically signed and sealed by Albani, Thomas, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on,any ,electronic copies. 699I pij*O' 'd" T #Ft;aiiii February 23,2018WARNING - Verify datsign parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 116111-7473 rev. 1"312015 BEFORE USE, Design valid for use only with MiTekllr connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verity the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. Foi-garteral guidance regarding the I faw fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIrTPll Quality Criteria, DSB-89 and SCSI Building Component 6904 Parke East Blvd, safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Mexandna, VA 22314. Tampa, FL 36610 Job T uss Truss Type Oty Ply Park Sq/ Sundance-1730-A T13325038 P1730A A3 HIP j2 1 ob Referprigiii o lion IW_ _ Mid -Florida Lumber, Barlow, FL. 8.130 s Sep 15 2017 MiTek Industries, Inc. Fri Feb 23 13:14:12 2018 Page 1 ID:3zzrE5595gHBgKdROwR6OYzkwee-z6kvfl86boOKBt 1 za WAxKf7a3xbf?Hj4bfrpB6ziF 5v 1-0 5.9-4 .. 11-0-0 15-0-0 19-0-024-2.12 30-0-0 0 5 94 5-2.72 4-0 0 4-0-0 5 2-12 5-9 4 1 0A Scale = 1,52.1 4x4 = 3x4 = 5 4x4 = 14 13 _ __ -_ 11 10 3x4 r 1. 5x4 11 3x4 = 3x8 = 1,5z4 II 3x4 J 3x8 11 _________........ .-... 19-0-0 , 2A-2 _t2 ._ I LOADING ( psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft L/d TCLL 20.0 Plate Grip DOL 1.25 TC 0.35 Verl(LL) 0,15 11-13 999 240 TCDL 10.0 Lumber DOL 1.25 BC 0.66 Verl(CT) 0.31 11-13 999 180 BCLL 0.0 Rep Stress Incr YES WS 0.37 HOrzfCT) 0.09 8 n/a n/a BCDL 10.0 Code FBC2017/TP12014 Matrix -MS LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No-2 WEBS 2x4 SP No.3 REACTIONS. ( lb/size) 2=1260/0-3-8, 8=126010-3-8 Max Horz 2=117(LC 17) Max Uplift 2=-360(LC 12), 8= 360(LC 13) PLATES GRIP MT20 244/190 Weight: 157 lb FT = 20% BRACING - TOP CHORD Structural wood sheathing directly applied or 3-7-14 oc purlins. BOT CHORD Rigid ceiling directly applied or 7-7-12 oc bracing. FORCES. ( lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-22631743, 3-4=-1777/635, 4-5=-1530/621, 5-6=-1530/621, 6-7=-1777/635, 7- 8=-2263f743 BOT CHORD 2-14=-584/1970, 13-14=-58411970, 11-13=-416/1616, 10.11=-59211970, 8-10=-592/1970 WEBS 3-13= 519/294, 4-13=-142/509, 5-13=-259/145, 5-11=259/144, 6-11=-142/509, 7-11=-5191295 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10, Vuft=140mph (3-second gust) Vasd=108mph, TCDL=4.2psf, BCDL=3.Opsf; h=25ft; Cat. II; Exp B; End., GCpi=0.18; MWFRS (envelope) gable end zone and C-C Extenor(2) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 11-0-0, Extenor(2) 11-0-0 to 23-2-15, Interior(1) 23-2-15 to 31-0-0 zone,C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1. 60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10,Opsf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 2=360, 8= 360. WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MI1-7473 rev. 10/0312015 BEFORE USE. Design valid for use only with MiTeklf connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system_ Before use, the building designer must verify the applicability of design parameters and property incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery. erection and bracing of trusses and truss systems, see ANSIrrPit Quality Criteria, OSB-89 and SCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312. Alexandria, VA 22314, This item has been electronically signed and sealed by Albani, Thomas, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on,any electronic codes. Thomas A Albion€, PE-Na.383 D Mi',ekkUSA inr Cart 6 6904 P8rk"'4' E 4yd fans Ft 3361/t February 23,2018 M61E. .''. 6904 Parke East Blvd. Tampa. FL 36610 Job LPI 730A A4A4 TrusT'u -- TPSS Type HI oty ,—Yll ParkSq/ Su—ndanoe- 1 7-30--A--- L.Rf, T13 325039 reng -q-(Qp Lio-nALt__. Mid-Flonda Lumber, Bartow, FL. 8.130 s Sep 15 2017 MiTek Industries, Inc. Fri Feb 23 1314 13 2018 Page 1 ID:3z7.rE5595qHBqKdROwR6OYzkwee-RIIHt58kM5XBp1cA7EiA"fl2LvSkm7DqJbNj7ziF5u 1 -0-01_ 4-9-4 9-0-0 + 5-0-0 1 -0-0 2-L2 30-070 4-94 4-2-12 06-0 6-0-0 4-2-12 4-9-4 1-0 Scale = 1 521 I 4x8 4 4X8 21 5 22 6 13 11 10 04 = 3x4 3x4 = 3x8 3x4 = 4x4 LOADING (psf) SPACING- 2-11-0 CSI. DEFL, in (loc) I/clefl L/d TCLL 20.0 Plate Grip DOL 1.25 TC 0.46 Verl(LL) -0.16 10-19 >999 240 TCDL 10.0 Lumber DOL 1.25 BC 0,81 Verl(CT) -035 10-19 >999 180 BCLL 0.0 Rep Stress Incr YES WB 0.23 Horz(CT) 0.09 8 n/a n1a BCDL 10.0 Code FBC2017fVPI2014 Matrix -MS LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD BOT CHORD 2x4 SP No.2 BOT CHORD WEBS 2x4 SP No3 REACTIONS. (lb/size) 2=1260/0-3-8,8=1260/0-3-8 Max Horz 2=-97(1-C 13) Max Uplift 2-338(LC 12), 8=-338(LC 13) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-22481797,3-4=19511683,4-5=-2021/766,5-6=20211766, 6-7=-19511683, 7-8=-2248f797 BOTCHORD 2-13=-64111986,11-13=-445/1696, 10-11=-453/1696, 8-10=-649/1986 WEBS 3-13=-340/245,4-13=-69/411, 4-1 1=-227/503,5-1 1=-414/252,6-11 1=-2271503, 6-10=-69/411, 7-10=-340/246 PLATES GRIP MT20 244/190 Weight: 150 lb FT = 20% Structural wood sheathing directly applied or 3-6-15 oc purlins. Rigid ceiling directly applied or 7-4-0 oc bracing. NOTES- 11 Unbalanced root live loads have been considered for this design. 2) Wind: ASCE 7-10, Vult=140mph (3-second gust) Vasd=108mph, TCDL=4.2psif; BCDL=3.Opsf, h=25ft, Cat. 11, Exp 8, Encl., GCpi=0.18, MWFRS (envelope) gable end zone and C-C Exterior(2) -1-0-0 to 2-0-0, Interior(l) 2-0-0 to 9-0-0, Extenor(2) 9-0-0 to 25-4-11, Intenor(l) 25-4-11 to 31-0-0 zone,C-C for members and forces & MWFRS for reactions shown, Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load noncorcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 2=338,8=338, AQ, WARNING - Verity design inuarn.1—nd READ NOTES ON THIS AND INCLUDED UITEK REFERENCE PAGE Affl,7473 m,. 10/0312016 BEFORE USE. Design valid for use Only With MiTekficonnectors. This design Is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or Chord members only. Additional temporary and permanent bracing is always required to, stability and to prevent Collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIrTPII Quality Criteria, DSEI-119 and BCSI Building Component Safety Information available from Truss Plate Institute. 218 N. Lee Street, Suite 312, Alexandra. VA 22314. This item has been electronically signed and sealed by Albani, Thomas, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified 9n,poy,Q,llBctronic copies. Thomas'k-Albainiff-N6,393 0 554F7rl February 23,2018 I " Iret 6904 Park* Fast Blvd, Tampa, FL 36610 tob Truss R1730A Aft 4 Truss Type ------ Qry Ply Park Sq!_ Sundance-1730-A R f r nc ti n I T13325040 Mid -Florida Lumber, Bartow, FL. 8.130 s Sep 15 2017 MiTek Industries, Inc. I D:3zzrE5595gHBgKd ROwR6OYzkwee-vUsf4R9M7Pf2QBBMhxDPP4CoFIEcT6BM3zKwF?ziF5t Fri Feb 23 13:14:14 2018 Page 1 14-0. 3-9-4 1-0-0 3-9-4 7-M 12-4-9 3-2-12^ mm 51-49 17-7-7 23-0-Q 26-2-t2 r w3-2-12 30-0-0 t-0-0 3-9-4 7.0.0 Scale = 1:52.1 8x10 MT20HS = 8x10 MT20HS = 3x4 = 1.5x4 II n f ` 4 20 21 5 22 23 24 6 25 26 15 _. __ 14 __ .- -- - W -- -- 11 08 = 3x4 = 5x8 MT20HS = 400 = 3x4 = 4x8 3x8 = LOADING (psf) SPACING- 2-0-0 CSI. TCLL 20.0 Plate Grip DOL 1.25 TC 0.88 TCDL 10.0 Lumber DOL 1.25 BC 0.82 BCLL 0.0 Rep Stress Incr NO WS 0.69 BCDL 10.0 Code FBC2017tTP12014 Matrix -MS LUMBER - TOP CHORD 2x4 SP No,2 `Except" 4-7: 2x4 SP DSS BOT CHORD 2x6 SP No.1 WEBS 2x4 SP No.3 REACTIONS, (lb/size) 2=252510-3-8, 9=2524/0-3-8 Max Harz 2=78(1_C 28) Max Uplift 2=-1140(LC 8), 9=-1140(LC 9) DEFL, in (loc) Udefl L/d PLATES GRIP Vert(LL) 0.37 12-14 >978 240 MT20 244/190 Vert(CT) -0.57 12-14 >631 180 MT20HS 187/143 Horz(CT) OA4 9 n/a n/a Weight: 176 lb FT = 20% BRACING - TOP CHORD Structural wood sheathing directly applied or 2-2-2 oc purlins. BOT CHORD Rigid ceiling directly applied or 4-8-8 oc bracing. FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3-5180/2387, 3-4=-4994/2355, 4-5=-5957/2871, 5-6=-5945/2864, 6-7=-5945/2864, 7-8-4996/2356, 8-9=-5181/2387 BOT CHORD 2-15=-2138/4605, 14-15=-2078t4471, 12-14=-281015957. 11-12=-2033l4473, 9-11=-2072/4606 WEBS 4-15=-243/793, 4-14=-916/1815, 5-14=695/489, 6.12=-677/480, 7-12=-905/1798, 7-11=-247/798 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10: Vult=140mph (3-second gust) Vasd=108mph; TCDL=4.2psf; BCDL=3.0psf, h=25ft, Cat. II; Exp B, Encl., GCpi=0,18, MWFRS (envelope) gable end zone: Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding, 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads, 6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint($) except (jt=1b) 2=1140,9=1140, 8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 219 lb down and 254 lb up at 7-0-0, 123 lb down and 142 lb up at 9-0-12, 123 lb down and 142 lb up at 11-0-12, 123 lb down and 142 lb up at 13-0-12, 123 lb down and 142 lb up at 15-0-0, 123 lb down and 142 lb up at 16-11-4, 123 lb down and 142 lb up at 18-11-4, and 123 lb down and 142 lb up at 20-114, and 219 lb down and 254 lb up at 23-0-0 on top chord, and 417 lb down and 213 lb up at 7-0-0, 89 lb down and 28 Ib up at 9-0-12, 89 Ib down and 28 Ib up at 11-0-12, 89 Ib down and 28 Ib up at 13-0-12, 891b down and 28 Ib up at 15-0-0, 89 Ib down and 28 Ib up at 16-11-4, 89 Ib down and 28 Ib up at 18-11-4, and 89 Ib down and 28 Ib up at 20-11-4, and 417 lb down and 213 Ib up at 22-114on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (8). LOAD CASE(S) Standard WARNfNG - Verity dasign parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 11,111.7473 rev. 1016312015 BEFORE USE. Design valid for use only with MiTek& connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability or design parameters and property incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabncalion, storage, delivery, erection and bracing of trusses and truss systems, see ANSIrTPit Quality Cntana, DSB-a9 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314, This item has been electronically signed and sealed by Albani, Thomas, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified On, pny tieClronlc Copies. ThomAA AlbatirPEltte.393 n k1 a% 1)SA If)e. Cett 86 6894Park E fBfvd.%a FL33610 February 23,2018 1N1RA 6904 Parke East Blvd, Tampa, FL 36610 FP17301---' Truss Truss Type Qry Ply Rark Sq! Sundance-1730-AT13325040 A5 HIR 1 1 Mid -Florida Lumber, Bartow, FL. 8.130 s Sep 15 2017 MiTek Industries, Inc. Fn Feb 23 13:14:14 2018 Page 2 _ I D: 3zzrE5595gHBgKdRQwR6QYzkwee-vUsf4R9M7Pf2QBBMhxDPP4CoF1EcT6BM3zKwF?ziF 5t LOAD CASE( S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads ( plf) Vert: 1- 4=-60, 4-7=-60, 7-10=-60, 2-9=-20 Concentrated Loads ( lb) Vert: 4=- 172(F) 7=-172(F) 15-417(F) 11=-417(F) 20=-123(F) 21=-123(F) 22-123(F) 23=-123(F) 24= 123(F) 25=-123(F) 26=-123(F) 27=-70(F) 28=-70(F) 29=70( F) 30=-70(F) 31=-70(F) 32=70(F) 33=-70(17) A WARNING • Verity design paameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MIf-7473 rev. 10/0312015 BEFORE USE. Design valid for use only with MiTek& connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing I` is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITPII Quality Criteria, DS849 and SCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Instaule, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa.. FL 36610 TJobTrussss P,::730A Mid -Florida Lumber, Barlow, FL. 8.130 s Sep 15 2017 MiTek Industries, Inc. Fit Feb 23 13:14 15 2018 Page 1 ID:3zzrE5595qHBqKdROwR6OYzkwee-Nh42HnA-uinv2LmYFfkeyll4h9YaCbZVvHd4UoRziF5s 1 _M1 4-9-4 9-0-0 13-6-0 I 18-0.0 1 M-0 24-5-12____+_ 30-0-0 1-0-0, 4-9-4 4-2-12 4.6.0 4-6-0 1-6-0 4-11-12 5-6-4 Scale = 1 53.0 l 4x4 = 4X4 II 4x4 = 7 13 12 4x4 = 3x8 = 5X8 == 3x4 = 3X4 1-8 12 LOADING (psf) SPACING- 2-0-0 TCLIL 20.0 Plate Grip DOL 1.25 C0.39 TCDL 10,0 Lumber DOL 1.25 6C 0.90 BCLL 0.0 Rep Stress Incr YES 049 BCDL 10.0 Code FBC2017rrPI2014 Matrix-MS LUMBER- TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 REACTIONS. ( lb/size) 9=126010-3-8, 2=126010-8-0 Max Horz 9= 111 (LC 13) Max Uplift 9=-355(LC 13), 2=-442(LC 12) DEFL. in (loc) I/defI L/d PLATES GRIP Vert( LL) -0.15 12-13 >999 240 MT20 244/190 Verl( CT) -0.37 12-13 >981 180 Horz( CT) -0.09 2 n/a n/a Weight: 156 lb FT = 20% BRACING - TOP CHORD Structural wood sheathing directly applied or 3-7-10 oc purlins, BOT CHORD Rigid ceiling directly applied or 7-4-15 oc bracing. FORCES. ( lb) - Max. Comp./Max, Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 7-8=-22001772, 8-9=22641710, 6-7=-2122/766, 4-5=-1708/643, 5-6-1910/685, 2-3= 2254/797, 3-4=-1955/671 BOT CHORD 2-13=-632/1991, 12-13=-520/1960,11-12=-366/1559, 9-11 =-54611974 WEBS 8- 11 =-314/245, 7-11 =-2801554, 7-12=-469/1288, 6-12-1042/405, 5-13=-366/198, 4-13=- 154/614, 3-13=-344/243 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10, Vult=140mph (3-second gust) Vasd=108mph; TCDL=4,2psf: BCDL=3.Opsf; h=25ft, Cat. III Exp B, Encl., GCpi=0.18 ' MWFRS (envelope) gable end zone and C-C Exterior(2) -1-0-0 to 2-0-0, Interior(l) 2-0-0 to 9-0-0, Exterior(2) 9-0-0 to 12.0-0, Interior(l) 18-0-0 to 31-0-0 zone;C-C for members and forces & MWFRS for reactions shown, Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcuFrent with any other live loads. 5) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except at=lb) 9=355,2= 442, A WARNING - Vienitv design p—rin.fr. and READ NOTES ON IWIS AND INCLUDED MITEK REFERENCE PAGE UJIJ473 rev. 1010312015 BEFORE USE. Design valid for use only with MiTekile connectors, This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verity the applicability of design parameters and prop" incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web andior chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse With possible personal injury and property damage. For general guidance regarding the fabncabon . storage, delivery, erection and bracing of trusses and truss systems, see ANSIfTPIl Quality Criteria, DS849 and SCSI Building Component Safety Information available from Truss Plate Institute, 218 N, Lee Street, Suite 312, Alexandria, VA 22314, This item has been electronically signed and sealed by Albani, Thomas, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on,poy electronic cop jes. Thomas'A, AIb;jniPEN6 33 0 a M 3904Pifjliftr ' a: ' V f 161y 59February23,2018 Irlow, 6904 Parke East Blvd. Tampa, FL 36610 Job Truss Truss Type Oty Ply Park Sqt Sundance-1730-A T13325042 P1730A A7 SPECIAL 1 1 4 P pt !1 Mid -Florida Lumber, Bartow, FL. 8.130 s Sep 15 2017 MiTek Industries, Inc. Fn Feb 23 13:14:16 2018 Page 1 ID:3zzrE5595gHBgKdROwR6OYzkwee-rt_OV6BcfOvmgUKlpMFtUVHGRYvVxOkfWHp1 KtziF5r p9`M 1-" 5-6-4 5.6.4 t0-6-0 — T - 134A_____..__4-0 4-11-12 2-1M 25.10-12 4-6-0 4-6.0 3-6-12 4-14 1.0.0 Scale = 1.530 3x4 3x4 = 06 II LOADING (psf) SPACING- 2-0-0 CSI. TCLL 20.0 Plate Grip DOL 1.25 TC 0.32 TCDL 10.0 Lumber DOL 1.25 BC 0.85 BCLL 0.0 Rep Stress Incr YES W3 0.62 BCDL 10.0 Code FBC2017/TP12014 Matrix -MS LLIMBER- TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 REACTIONS. lb/size) 2=1260/0-3-8, 9=1260/0-8-0 Max Horz 2=111(LC 12) Max Uplift 2= 355(LC 12), 9=-442(LC 13) 13 5x8 T 4x4 3x8 = DEFL. in (loc) I/deft L/d Vert(LL) -0.17 11-13 >999 240 Vert(CT) -0.41 11-13 >880 180 Horz(CT) 0.09 9 n/a n/a 3x4 = PLATES GRIP MT20 244/190 Weight: 152 lb FT = 20% BRACING - TOP CHORD Structural wood sheathing directly applied or 3-6-9 oc pudins. BOT CHORD Rigid ceiling directly applied or 7-4-3 oc bracing. FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2244/717, 3-4=-2116/731, 4-5=-2655/944, 5-6=-2304/791, 6-7=-1814/667, 7-8=-2054/702,8-9=-2293/804 BOT CHORD 2-14=-546/1971, 13-14=-36311550, 11-13--636/2234, 9-11=-645/2025 WEBS 3-14=-314/240, 4-14=-221/504, 4-13=-596/1638, 5-13=-1339/525, 6-11=-5631234, 7-11=-176/ 675, 8-11=-270/199 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10, Vult=140mph (3-second gust) Vasd=108mph; TCDL=4.2psf, BCDL=3.Opsf; h=25ft; Cat. II; Exp B. Encl., GCpi=0.18; MWFRS (envelope) gable end zone and C-C Exterior(2) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 10-6-0, Exterior(2) 10-6-0 to 25-4-0, Interior(1) 25-4-0 to 31-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Ot=lb) 2=355, 9= 442. WARNING • Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 11,111•7473 rev. 1010312015 BEFORE USE. Design valid for use only with MiTeke connectors. Tnis design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verily the applicability of design parameters and property incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSUTPi1 Quality Criteria, DSB-89 and BCSI Building Component safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria. VA 22314. This item has been electronically signed and sealed by Albani, Thomas, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified gnarly lectroniC co es. Tlxamas A Alb a1 PE•Nd @3 tst9i'ati i SA l c.= Cart && K-'.-, 889C Park1 Et'Blvd. a 3381R D te4 February 23,2018 t .:: 6904 Parke East Blvd. Tampa,. FL 36610 Job Tn ss Truss Type Oty PyParrikq]LIndance-17"-AT13325044P1730AA8SPECIAL1- loRt Mid -Florida Lumber, Bartow, FL. 8.130 s Sep 15 2017 MiTek Industries, Inc. Fri Feb 23 13:14:17 2018 Page 1 ID:3zzrE5595gHBgKd ROwR6OYzkwee-K3YoiSBFPKI dHevxM4m61 jgHPyGkgPBplxZasKziFSq 10-6-0 15.4.0 19-,11-12 24-4-0 26-10-12 30-0-0 t-0-0 5-6-4 .. 4-41.12 4-10-0 —` 4-7-12 4-4-4 2-Fi-12 3-1-4 1-0 Scale = 1 53D 4x4 II 16 15 13 12 __ -" II 4x5 = 2x4 II 4x10 = 5x8 MT20HS = 8x8 = 64 = 300 LOADING (psf) SPACING- 2-0-0 CSI. TCLL 20.0 Plate Grip DOL 1,25 TC 0.95 TCDL 10.0 Lumber DOL 1,25 BC 0.79 BCLL 0.0 Rep Stress Incr NO WEI 0.87 BCOL 10.0 Code FBC2017/TPI2014 Matrix -MS LUMBER - TOP CHORD 2x4 SP No.2 'Except' 5-7: 2x4 SP No.1 BOT CHORD 2x6 SP No.i 'Except' 9-14: 2x6 SP DSS WEBS 2x4 SP No.3 REACTIONS. (lb/size) 2=1746/0-3-8, 9=259410-8-0 Max Horz 2=111(LC 12) Max Uplift 2--588(LC 8), 9=-10771LC 9) 2x4 II DEFL, in (loc) Itdefl L/d Vert(LL) 0.34 12-13 >999 240 Vert(CT) -0.60 12-13 >598 180 Horz(CT) 0.12 9 ma n/a PLATES GRIP MT20 244/190 MT20HS 187/143 Weight: 178 lb FT = 20% BRACING - TOP CHORD Structural wood sheathing directly applied. BOT CHORD Rigid ceiling directly applied or 5-5-11 oc bracing. WEBS 1 Row at midpt 5-15 FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-3407/1120, 3-4=-2955/1097, 4-5=-2943/1071, 5-6=-6424/2620, 6-7=-6424/2620, 7-8=-5351/2242,8-9=-5441/2274 BOT CHORD 2-16=-1015/2999, 15-16=-1015/2999, 13-15=-2095/5795, 12-13=-2090/5792, 11-12=-1874/4725, 9-11=-1957/4814 WEBS 3-15=-491/265, 4-15=-825/2276, 5-15=-3716/1554, 7-11=-328/896, 6-12=-3061209, 5-12=- 769/874, 7-12=-712/2021 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=140mph (3-second gust) Vasd=108mph, TCDL=4.2psf; BCDL=3.Opsf, h=25ft; Cat. 11, Exp B; Encl., GCpi=0. 18, MWFRS (envelope) gable end zone; Lumber DOL=1.60 plate grip DOL=1,60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) ' This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb) 2=588, 9=1077. 8) Hanger( s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 126 lb down and 115 lb up at 22-11- 4, and 155 Ib down and 160 lb up at 24-4-0 on top chord, and 1285 lb down and 552 lb up at 21-1-8, and 64 lb down and 24 lb up at 22-11-4, and 299 lb down and 153 lb up at 24-4-0 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE( S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=115, Plate Increase=1.25 Uniform Loads ( plf) Vert: 1- 4=-60, 4-5=-60, 5-7=-60. 7-10=-60, 2-9=-20 WARNINO - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MIb7473 rev. 10/03/2015 BEFORE USE. Design valid for use only with MiTeke connectors. This design is based only upon parameters shown, and is for an individual building component. not a truss system. Before use, the building designer must verity the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery,. erection and bracing of trusses and miss systems, see ANSIrrPI1 Quality Citteria, DS849 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. This item has been electronically signed and sealed by Albani, Thomas, PE using a Digital Signature. Printed copies of this document are not Considered signed and sealed and the signature must be verified on ,pry electronic co a.393 pies. T¢ rnasAAjbarnPEt4Mtalf, 11SA, Ins< 'Carl 66 , -_r... B904Park># sF61yd. Ta L39&1 February 23, 2018 m .. 6904 Parke East Blvd. Tampa, FL 36610 lab P, 730A TrussType SPECIAL 17 T13325043 JAB Mid -Florida Lumber, Bartow, FL. 8,130 s Sep 15 2017 MiTek Industries, Inc, Fri Feb 23 ID:3z,zrE5595qHBqKdROwR6OYzkwee-K3YoiSBFPK1dHevxM4m61jqHPyGkgPBplxzasKziF5q 13:14A7 2018 Page 2 LOAD CASE(S) Standard Concentrated Loads (lb) Vert: 7=98fl 1 1=-299(F) 21 86(F) 22=1285(1`) 23=-53(F) A WARNING- Varifydesign prare.r.and READ NOTES ON THIS AND INCLUDED UITEK REFERENCE PAGE MII.7473rav, 101031201-5BEFORE USE. Design valid for use Only With MlTelk(lf) connectors. This design is based only upon parameters shown, and is for an individual building component, not a buss SSsystem, Before use. the building designer must venty the applicability of design parameters and property incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual tress web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss Systems, See ANSIrrPI1 Quality Criteria, DSO-89 and SCSI Building Component 6904 Parke East Blvd, Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL WIO b Truss POI Truss Type Ory Ply Pa k Sq! Sundance-1730-A T13325044 730A B1 COMMON t 1 Mid -Florida Lumber, Bartow, FL. 8.130 s Sep 15 2017 MiTek Industries, Inc. Fri Feb 23 t 3:14:18 2018 Page 1 I D:3zzrE5595gHBgKdROwR6OYzkwee-oF6AwaCtAe9UvoU7wnHLawNbnMg 1 P l ?yzbl8OmziF5p 1-0-0 " 4 10-6.0 1-0-0 4-11-12 5-6-4 1-" Scale = 1:38.1 4x4 = I 3x4 = 3x4 = 3x4 3x4 = 3x4 = LOADING (psi) SPACING- 2-0-0 CSL TCLL 20.0 Plate Grip DOL 1.25 TC O.33 TCDL 10,0 Lumber DOL 1.25 BC 0.53 BCLL 0.0 Rep Stress Incr YES WB 0,19 BCDL 10.0 Code FBC2017/TPI2014 Matrix -MS LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 REACTIONS. (lb/size) 2=900/0-8-0, 6=90010-8-0 Max Horz 2=111(LC 12) Max Uplift 2=-286(LC 12), 6=-286(LC 13) FORCES. (lb) -Max, Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1451/448, 3-4=-1302/450, 4-5=-1302/450, 5-6=-1451/448 BOT CHORD 2-10=-412/1264, 8-10=174/836, 6-8=-329/1264 WEBS 4-8=-204/501, 5-8=-3231243, 4-10=-204/501, 3-10=-3231243 Im d DEFL. in loc) I/deft L/d PLATES GRIP Vert(LL) -0.06 8-16 >999 240 MT20 244/190 Vert(CT) -0.15 8-16 >999 180 Horz(CT) 0.04 6 n/a n/a Weight: 97 lb FT = 20% BRACING - TOP CHORD Structural wood sheathing directly applied or 4-7-1 oc purlins. BOT CHORD Rigid ceiling directly applied or 9-1-1 oc bracing. NOTES- 1) Unbalanced roof live loads have been considered for this design, 2) Wind: ASCE 7-10; Vult=140mph (3-second gust) Vasd=108mph, TCDL=4.2psf, BCDL=3.Opsf; h=25ft; Cat. ll; Exp B; Encl., GCpi=0,18, MWFRS (envelope) gable end zone and C-C Extenor(2) -1-0-0 to 2-0-0, Intenor(1) 2-0-0 to 10-&0, Exterior(2) 10-6-0 to 13-6-0 zone:C-C for members and forces & MWFRS for reactions shown, Lumber DOL=1.60 plate grip DOL=L60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) " This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joints) except Ot=lb) 2=286, 6=286, This item has been electronically signed and sealed by Albani, Thomas, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on,any electronic copies. ThomaS Albjrl7PE Nb.383 01 10 fek USA'I1c 'Cart 66 69i14 Pa4igi'EWd sP F SBtG February 23,2018 A&WARNING- Verffy design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE M/F7477 rev, 10/03/2015 BEFORE USE. Design valid for use only with MiTek(li) connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use. the building designer must venty the applicability of design parameters and property incorporate this design into the overall building design_ Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing K ldfxf is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the [,i6 fabrication, storage, delivery, erection and bracing of trusses and miss systems, see ANSIITPII Quality Criteria, DSB-89 and SCSI Building Component 6904 Parke East Blvd, Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314, Tampa, FL 36610 Do Q Ply Park Sq, Sundncei,l 730-A r1b Truss Truss Type55 T13325045 P, Hip 17301a2 . ......... Mid -Florida Lumber, Bartow, FL. 8.130 s Sep 15 2017 MiTek Industries, Inc. Fit Feb 23 13:14 19 2018 Page 1 ID:3zzrE5595qHBqKdROwR6OYzkwee-GSfY78DVxxHLXy3KUVoa68vkKm-b8UN5CF2hxCziF5o 1 -M 4-94 12-0-0 16-2-12 21-0-0 22-" Scale = 1 37,5 4x8 4X4 ch 4 4x4 = 5X5 = 3X8 = 04 LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (loc) I/defl L/d PLATES GRIPS TCLL 20.0 Plate Grip DOL 1.25 TC 0.47 Vert(LL) -015 9-16 >999 240 MT20 244/190 TCDL 10.0 Lumber 001- 1,25 BC 0.70 Vert(CT) -0.32 9-16 >780 180 BCLL 0.0 Rep Stress Incr YES WB 0.18 Horz(CT) 0.04 7 n/a ri/a BCDL 10.0 Code FBC2017/TP12014 Matrix -MS PLATES 104 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 4-6-1 OC purlins. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 9-0-15 oc bracing. WEBS 2x4 SP No.3 REACTIONS. (lb/size) 2=900/0-8-0,7=900/0-8-0 Max Herz 2=97(LC 12) Max Uplift 2=-274(LC 12), 7=274(!_C. 13) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=1462/541, 3-4=1156/427, 4-5=-974/424, 5-6=-1149/424, 6-7=-1461/541 BOT CHORD 2-10=-413/1288, 9-10=-213/971, 7-9=-421/1288 WEBS 3- 1 0=-361/246, 4-1 0=-87/317, 5-9-81/321, 6-9=-365/249 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10. Vuh=140mph (3-second gust) Vasd=108mph, TCDL=4.2psf, BCDL-3,Opsf; h=25ft, Cat III Exp B, End_ GCpi=O, 18, MWFRS (envelope) gable end zone and C-C Exterior(2) -1-0-0 to 2-0-0, Interior(l) 2-0-0 to 9-0-0, Extenor(2) 9-0-0 to 12-0-0, Inlenor(l) 16-4-11 to 22-0-0 zone,C-C for members and forces & MWFRS for reactions shown, Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water pending. 41 This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20,Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the Whom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Ot=lb) 2=274,7=274, This item has been electronically signed and sealed by Albani, Thomas, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on,arly electronic copies, or1rT"mas"kAib4'niPENo'3" 0 0ek u Cart 6 February 23,2018 WARNING - Verity design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 nsv. 1010312015 BEFORE USE. Design valid for use only with MiT61,40 connectors, This design IS based only upon parameters shown, and is for an Individual building component, not a truss system Before use, the building designer must verity the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the Raw, fabrication, storage, delivery, erection and bracing of trusses and truss systems. See ANSlrTPl1 Quality Criteria, DSB-89 and BCS1 Building Component 6904 parka East Blvd. safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandra, VA 22314, Tampa, FL 36610 Job Tnass Truss Type Ory Ply Park Sqt Sundance-1730-A T13325046 P1730A 62A HIP 1 1 doh ElgfgySjgPti n _ __ Mid -Florida Lumber, Bartow, FL. 8.130 s Sep 15 2017 MiTek Industries, Inc, Fn Feb 23 13:14:20 2018 Page i I D:3zzrE5595gHBgKdROwR6OYzkwee-keDxLUE7iFPB86e W2CKpfLSvs9lmtxZFRvnETfziF5n 10-0 4-94 9-0-0 12-0-0 16-2-12 2-12 2L0-0 4 _._.. ...)____._._....._3-0- 4-2.12 ____.. .... 4-9-4 Scale = 1:36.0 4x4 4x8 = I 4x4 = 3x8 = 4x4 = 3x4 = 4x4 = LOADING (psf) SPACING- 2-0-0T-BC I. DEFL. m in (loc) Itdefl L/d PLATES GRIP Y TCLL 20.0 Plate Grip DOL 1.25 0.49 Vert(LL) -0.15 8-13 >999 240 MT20 2441190 TCDL 10.0 Lumber QOL L25 0.71 Vert(CT) -0.33 8-13 >769 180 BCLL 0.0 Rep Stress Incr YES WB 0,19 Horz(CT) 0.04 7 n/a n/a BCDL 10.0 Code FBC2017rrPI2014 Matrix -MS Weight: 102 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 4-5.1 oc puffins. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 8-9-0 oc bracing. WEBS 2x4 SP No.3 REACTIONS. (lb/size) 7=839/Mechanical, 2=90110-3-8 Max Horz 2= 107(LC 12) Max Uplift 7=- 243(LC 13), 2=-274(LC 12) FORCES, (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2- 3=1464/550, 3-4=-11521433, 4-5=-977/432, 5-6=-1154/435, 6-7=-1471 /546 BOT CHORD 2-10= 45311290, 8-10=238/978, 7-8=-440/1298 WEBS 3.10=365/ 248, 4-10=-81/321, 5-8=-89/323, 6-8=-373/253 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7- 10, Vult=140mph (3-second gust) Vasd=108mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft, Cat. 11, Exp B; Encl., GCpi=0.18, MWFRS ( envelope) gable end zone and C-C Extenor(2) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 9-0-0, Extenor(2) 9-0-0 to 12-0-0, Interior( 1) 16-4-11 to 21-0-0 zone,C-C for members and forces & MVJFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Refer to girder( s) for truss to truss connections. 7) Provide mechanical connection ( by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except W=lb) This item has been 7=243, 2=274. electronically signed and sealed by Albanj, Thomas, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on,any lectronic copies. Thamas A illb iif frE Nu A3 ° MiCekt SA Ir1o(Carttl6 ' 8g9A Park'H s` fBiyd rf s881,tk February 23,2018 WARNING, Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MIb7473 rev, 10/03/2015 BEFORE USE. Design valid for use only with MiTek6 connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verity the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing INT is always required forstabilityandtopreventcollapsewithpossiblepersonalinjuryandpropertydamage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIfTP11 quality Criteria, DSB a9 and BCSI Building Component 6904 Parke East Blvd, Safety Information available from Truss Plate Institute, 218 N. lee Street. Suite 312, Alexandria, VA 22314, Tampa, FL 36610 rJob TrussITrussTypeotyPlyParkSq/ Sndance-7730-A A 63 HIP Mid -Florida Lumber, Bartow, FL. o R f o It 8,130 s Sep 15 2017 MiTek Industries, Inc. Fri Feb 23 13:14:21 2018 Page 1 I D:3zzrE5595gHBgKdROwR6OYzkwee-CgnJYgFITZX2mGDibvr2BZ?5TZcEcM WOgZXo?5ziF5m 1-0-0 i-0 3-9-4 3-9-4 7-0-0 3-2-12 108-0 14-0-0 17.2-12 21 3-" 3-0-0 3.2-122 3-9-4 61-0-0 Scale = 1:37.5 4x8 1.Sx4 I 08 = 4 20 5 21 6 I 4x6 -.._ 3x4 = 4.6 '- 3x8 = 3x4 = 4x6 = Plata Offsets X Y 4:05-4 0-2-0[6 0 5 4QQj _ LOADING (psf) SPACING- 2-0-0 CSI. TCLL 20,0 Plate Grip DOL 1.25 TC 0.43 TCDL 10.0 Lumber DOL 1.25 BC 0.88 BCLL 0.0 Rep Stress Incr NO WS 0.27 BCDL 10.0 Code FBC2017/TPI2014 Matrix -MS LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 REACTIONS. lb/size) 2=1778/0-8-0, 8=1778/0-8-0 Max Horz 2-78(LC 8) Max Uplift 2=-821(LC 8), 8=-821(LC 9) DEFL. in (loc) I/defl L/d Vert(LL) 0.16 11 >999 240 Vert(CT) -0,24 11 >999 180 Horz(CT) 0.10 8 n/a n/a PLATES GRIP MT20 244/190 Weight: 108 lb FT = 20% BRACING - TOP CHORD Structural wood sheathing directly applied or 3-0-1 oc puffins. BOT CHORD Rigid ceiling directly applied or 4-11-0 oc bracing. FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=3435/1631, 3-4=-3218/1553, 4-5=-3226/1591, 5-6=3226/1591, 6-7=-3217/1553, 7-8 =-3434/1631 BOT CHORD 2-13=146013034, 11-13=-133112871, 10-11=-128912870, 8-10=-138213034 WEBS 3-13=-253/218. 4-13=-218/705, 4-11=-309/554, 5-11=- 524/379, 6-11=-310/556, 6-10=-218/703, 7-10=-253/219 NOTES- 1) Unbalanced roof live loads have been considered for this design, 2) Wind: ASCE 7- 10; Vint=140mph (3-second gust) Vasd=108mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; Cat. II; Exp B, Encl., GCpi=0.18; MWFRS (envelope) gable end zone, Lumber DOL=1 60 plate grip 60L= 1.60 3) Provide adequate drainage to prevent water ponding, 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) " This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 2=821,8=821, 7) Hanger(s) or other connection devices) shall be provided sufficient to support concentrated load( s) 219 lb down and 254 lb up at 7-0-0, 123 lb down and 142 lb up at 9-0-12, 123 lb down and 142 lb up at 10-6-0, and 123 lb down and 142 lb up at 11-11-4, and 219 lb down and 254 lb up at 14-0-0 on top chord, and 417 lb down and 213 lb up at 7-0-0, 89 lb down and 28 Ib up at 9-0-12, 89 Ib dawn and 28 Ib up at 10.6-0, and 89 Ib down and 28 Ib up at 11-11-4, and 4171b down and 213 lb up at 13-114on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead r Roof Live (balanced): Lumber Increase=1.25, Plate Increase= 125 Uniform Loads (plf) Vert: 1-4=-60, 4-6=-60, 6-9=-60, 14-17=-20 Concentrated Loads (lb) Vert: 4=-172(F) 6=-172(F) 12=-70(F)13=-417(F) 11=-70(F) 5=-123(F) 10=-417(F) 20=-123(F) 21=-123(F) 22 =70(F) WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE M11-7473 rev. 14/03/2015 BEFORE USE. Design valid for use only with MiTek2d connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system, Before use, the building designer must verily the applicability of design parameters and property incorporate this design into the overall building design, Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabncat inn. storage, delivery, erection and bracing of Trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB49 and BCSI Building Component Safety Information available from Truss Plate Instnuie, 218 N. Lee Street, Suite 312. Alexandna, VA 22314, li This item has been electronically signed and sealed by Albani, Thomas, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on,,poy glectronlc copjes. Thomask Allbini BE Xo 39380 Nl1`e-et) SA, I ,. F"t Cert 66 68&1Park; FE Iv -ata February 23, 2018 M eL 6904 Parke EastBlvd, Tampa, FL 36610 TruSS Truss Type ty PW __ Park Sq/ Sundance-1730-A T13 0413Llob730AB311p Refgrg9ge JQ"t 9pA1L___ Mid -Florida Lumber, Bartow, FL 8.130 s Sep 15 2017 MiTek Industries, Inc. Fit Feb 23 13:14:22 2018 Page 1 10:3zzrE5595qHBqKdROwR6OYzkwee-glLhmAFNEsfvOPou9dMHkmXGDzyHLptYuDGLXXziF5I 3-9-4 7-" T2.12 14-0-0 17-2-12 21-0-0 3-6-03-6-0 3-2-12 3-9-4 Scale = 1 36,7 4x8 18 1.5x4 11 4x8 5 19 6 4X6 = 3x4 = 5x8 = 3x4 = 00 LOADING (psf) SPACING- 2-0-0 CSI. TCLL 20,0 Plate Grip DOL 1.25 TC 0.43 TCDL 10.0 Lumber DOL 1.25 BC 0,89 BCLL 0.0 Rep Stress Incr NO WB 0.26 BCDL 10.0 Code FBC2017rrPI2014 Matrix -MS LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 REACTIONS. (IbIsize) 8=1717/Mechanical, 2=1780/0-3-8 Max Horz 2-87(LC 8) Max Uplift 8=-790(LC 9), 2=-821 (LC 8) DEFL. in (loc) Well Ltd PLATES GRIP Vert(LL) 0.16 10 >999 240 MT20 244/190 Vert(CT) -0.25 10 >999 180 Horz(CT) 0.10 8 n/a n/a Weight: 106 lb FT = 20% BRACING - TOP CHORD Structural wood sheathing directly applied or 2-11-15 oc purlins. BOT CHORD Rigid Ceiling directly applied or 4-10-13 oc bracing. FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=3437/1631, 3-4=-3221/1553, 4-5=-3230/1594, 5-6=323011594, 6-7=-3225/1557, 7-8=-3439/1639 BOT CHORD 2-11-1469/3037, 10-11 =-1341/2873, 9-10=-1299/2877, 8-9=-1410/3048 WEBS 3-1 1=253/1155, 4-1 1=-223/685, 4-10=-3101558, 5-10=-5241379, 6-10=-3091555, 6-9=-228/688, 7-9-2601162 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10: Vult=140mph (3-second gust) Vasd=108mph ' TCDL=4.2psf ' BCDL=3.Opsf, h=25ft, Cat. 11; Exp B. Encl., GCpi=0.18, MWFRS (envelope) gable end zone, Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding, 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Refer to girder(s) for truss to truss Connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Ot=ib) 8=790, 2=82 1. 8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 224 lb down and 251 lb up at 7-0-0, 123 lb down and 142 lb up at 9-0-12, 123 lb down and 142 lb up at 10-6-0, and 123 lb down and 142 lb up at 11-11-4, and 224 lb down and 251 lb up at 14-0-0 on top chord, and 411 lb down and 219 lb up at 7-0-0, 89 lb down and 28 lb up at 9-0-12, 89 lb down and 28 lb up at 10-6-0, and 89 lb down and 28 lb up at 11-114, and 411 lb down and 219 lb up at 13-114 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASES) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25. Plate lncrease=1.25 Uniform Loads (plo Vert: 1-4=-60, 4-6=-60, 6-8=-60, 12-15-20 Concentrated Loads (lb) Vert: 4=177fl 6=-177(F) 1 1=-41 1(F) 10=70fl 5=1 23(F) 9=41 I(F) 18=-123(F) 19=123fl 20=-70(F) 21 =70(17) AWARNING - Verify design parameters end READ NOTES ON THIS AND INCLUDED A41TEK REFERENCE PAGE 01-7473 rev, IOX312015 BEFORE USE. Design valid for use only with MiTek(l) correctors. This design is based only upon parameters shown and is for an individual building component, not a truss system. Before use, the building designer must verity the applicability of design parameters and property incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web andlor chord members only. Additional temporary and permanent bracing Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems. see ANSIrTPll Quality Criteria, OSS-89 and SCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Nexandna, VA 22314, This item has been electronically signed and sealed by Albani, Thomas, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified pn, pqy,p,lectronic cop jes. TftomaS'A-AJb;i'niPE No '393 0 141,' Usklnli.Wtce; -L-" 8984 txt* ti"a February 23,2018 Now 6904 Parke East Blvd, Tampa, FL 36610 7Qjy Ply J: Pad,'9ql' , — _-1130-AundainceTrussTrussrussTypeSSS T13325049 COMMONLP1730A ____Cl COMMON t pence pj) . .. .... E9 Mid -Florida Lumber, Barlow, FL. 8.130 s Sep 15 2017 MiTek Industries, Inc. Fn Feb 23 13:14:23 2018 Page 1 ID:3zzrE5595qHBqKdROwR6OYzkwee-8Dv3zWG??Anm?ZN5jKtWG-4TDNRy4Jlh7tOv4zziFSk 1-0-0 4-10-0 9-0-0 4-10-0 4-2-0 Scale = 1 19.9 04 2X4 = LOADING (psf) SPACING- 2-0-0 cSI. DEFL, in (loc) I/defl Lid PLATES GRIP TCLL 20.0 Plate Gnp DOL 1.25 TC 0.29 VerI(LL) 0,03 6-9 >999 240 MT20 244/190 TCDL 10,0 Lumber DOL 1.25 SC 0.29 Vert(CT) -0.04 6-9 >999 180 BCLL 0.0 Rep Stress Inrr YES VVEI 0.08 Horz(CT) 0.00 5 nice n/a BCDL 10.0 Code FBC20171TPI2014 Matnx-MP Weight: 36 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc puffins. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 Do bracing. WEBS 2x4 SP No.3 SLIDER Right 2x4 SP No.3 1-10-10 REACTIONS, (IbIsize) 2=418/0-8-0, 5=35210-1-8 Max Horz 2=76(LC 12) Max Uplift 2=-142(LC 12),5--103(LC 13) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-4451203, 3-5=-3831223 BOT CHORD 2-6=-1211342, 5-6=1 211342 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10, VuR=140mph (3-second gust) Vesd=108mph, TCDL=4.2psf, BCDL=3.Opsf, hm25ft, Cat. If; Exp B: Encl., GCpi= 0.18 ' MjAFRS (envelope) gable end zone and C-C Exterior(2) -1-0-0 to 2-0-0, Interior(l) 2-0-0 to 4-10-0, Extenor(2) 4-10-0 to 7- 10-0 zone:C-C for members and forces & MV`vFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Bearing at joint(s) 5 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface, 6) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 5, 7) Provide mechanical connection (by others) of truss to bearing plate Capable of withstanding 100 lb uplift at joint(s) except Ot=lb) This item has been 2= 142,5=103. electronically signed and 8) Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.500in. seated by Albani, Thomas, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on. arly qlectronic copies. 1MJeKUSA J D. cart sit I February 23, 2018 WARNINO. Verify design parameters nd READ NOTES ON THIS AND INCLUDED A#ITEK REFERENCE PAGE 11411.7473 rev. 1"3/2015 BEFORE USE. Design valid for use only with MiToke connectors, This design is based only upon parameters Shown and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing Is always required for stability and to prevent collapse with possible personal injury and property damage, For general guidance regarding the Piro fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITPII Quality Criteria, DSBA9 and BCSI Building Component 6904 Parke East Blvd, Safety information available from Truss Plate institute. 218 N. Lee Street, Suite 312. Alexandria, VA 22314. Tampa, FL W10 1 TrusssS' Oty Ply Paw-Sq-/ S—undance- 17PaS47 Fob T13325050 P, 730A C2 11P 1 1 ol R I ye iqn ILg& -a- Mid-Florida Lumber, Bartow, FL. 8.130 s Sep 15 2017 MiTek Industries, Inc. Fri Feb 23 13:14:24 2018 Page 1 ID:3zzrE5595qHBqKdROwR6OYzkwee-r-PTRArHemUvddjyHH20lpBdd5nodpnkrMwScQziF5j 1-M 1-M 3-0-0 310-0 3-8-0 2-4-0 Scale = 1 19,3 4x4 = 16 17 4 4X8 = 6,00 12 5 3x4 2 19 8 3.4 = 20 21 7 3,6 111.5x4 11 2X4 = LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (loc) Well Ltd PLATES GRIP TCLL 20.0 Plate Grip DOL L25 TC 0.34 Vert(LL) 0,01 7-8 >999 240 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.20 Vert(CT) -0.02 7-8 >999 180 BCLL 0.0 Rep Stress Incr NO We 0.05 HoFz(CT) -0.01 2 n/a n1a BCDL 10.0 Code FBC2017rrPI2014 Matrix -MP Weight: 41 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 2x4 SP No.3 SLIDER Right 2x4 SP No,3 1-10-10 REACTIONS. (lb/size) 6=352/0-1-8,2=418/0-8-0 Max Horz 6=59(LC 8) Max Uplift 6=-186(LC 9),2=-187(LC 9) Max Grav 6=367(LC 2), 2=480(LC 19) FORCES. (lb) - Max. Comp./Max, Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 4-6--527/269, 3-4=-564/288, 2-3=-6631317 BOT CHORD 2-8-239/557, 7-8--199/452, 6-7=-199/446 NOTES- 1) Unbalanced roof live loads have been considered for this design, 2) Wind: ASCE 7-10. Vuft=140mph (3-second gust) Vasd=108mph, TCDL=4.2psf, BCDL=3.Opsf, h=25ft, Cat. 11, Exp B; Encl., GCpi= 0.18; MWFRS (envelope) gable end zone: Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10,0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Bearing at joint(s) 6 considers parallel to grain value using ANSIfrPl I angle to grain formula, Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 6. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 6= 186,2=187. 9) Gap between inside of top Chord bearing and first diagonal or vertical web shall not exceed 0.500m. 10) Hanger(s) or other connection device(s) shall be provided sufficient to Support concentrated load(s) 159 lb down and 110 lb up a, -11- 4-0, 71 lb down and 52 Ito up at -13-2-0, 172 Ito down and 117 Ito up at -14-11-4, 77 lb down and 104 lb up at 24-0, and 35 lb down and 50 lb up at 4-2-0, and 84 lb down and 103 lb up at 5-11-4 on top chord, and 104 Ito down and 8 lb up at -11-4-0, 52 lb down and 4 Ito up at -13-2-0, 127 lb down and 6 Ito up at -14-11-4, 44 lb down and 25 lb up at 2-4-0, and 25 Ito down and 13 lb up at 4-2-0, and 72 lb down and 28 lb up at 5-11-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 11) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (8). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25. Plate Increase=1.25 WARMING - Verify design ininun.1— and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 11#11-7473re, 10/03/2015 BEFORE USE. Design valid for use only with MiTek(li)comiectors. This design is based only upon parameters shown, and is for an individual building component. not a truss system. Before use, the building designer Must verity the applicability of design parameters and properlymCOrpOrate this design into the overall building design, Bracing indicated is to prevent buckling of individual truss web andlor Chord members only. Additional temporary and permanent bracing s always required for stability and to prevent Collapse with possible personal injury and property damage, For general guidance regarding the fabrication, storage, delivery, erection and bracing of musses and truss systems. see ANSIITP11 Quality Criteria, DSB49 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N, Lee Street, Suite 312, Alexandra, VA 22314, This item has been electronically signed and sealed by Albani, Thomas, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on., aQy electronic copies. Thomas k AlbiniPEN6'393 0" M 4,kOSA,'Ilc, 'Certff- February 23,2018 I " m 1 6904 Parke East Blvd. Tampa, FL 36610 0" PE17 -10 1,. TT Truss Type C2 I I P P-' SfPlyParkSq/ Sundance-1 730-A T13317 I r 01 IL Mid-Flonda lumber, Bartow, FL. 8.130 s Sep 15 2017 MiTek Industries, Inc. Fri Feb 23 1314:24 2018 Page 2 ID:3zzrE5595qHBqKdROwR6OYzkwee-cPTRArHemUvddjyHH20lpBdd5nodpnkrMvvlScOziF5j LOAD CASE(S) Standard Uniform Loads (plf) Vert: 4-6=60, 3-4=-60, 1-3=-60, 9-13=-20 WARNING - Verity design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 11411.7473 rev. 10/03/2015 BEFORE USE. Design valid for use only with M.Teke connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system, Before use, the building designer must verity the applicability of design parameters and property incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web andior chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse won possible personal injury and property damage, For general guidance regarding the Iwaa fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIrrPli Quality Criteria, DSB-89 and BCS1 Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute. 213 N. Lee Street, Suite 312, Alexandria, VA 22314, Tampa, FL 36610 Job f.—S $ —T. TrTruss Y16 oty Park --1730-ASq/ S.ndance, P1730A Julss JACK 18 P T133250517T1332505]1 T R I rence tjOnqlLRIrenc Mid -Florida Lumber, Barlow, FL. 8,130 s Sep 15 2017 MiTek Industries, Inc. Fri Feb 23 13:14:25 2018 Page I ID:3zzrE5595qHBqKdROwR6OYzkwee-5c1qOBIGXnIUFtVVTqlv—MP9s8ASnYEi_aAV'?8sziF5i 1-M LOADING (pso SPACING. 2-0-0 CS" TCLIL 20.0 Plate Grip DOL 1.25 TC 0.07 TCDL 10.0 Lumber DOL 1.25 BC 0.01 BCLL 0,0 Rep Stress Incr YES WB 0.00 BCDL 10.0 Code FBC20171TPI2014 Matnx-MP LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 REACTIONS. (lb/size) 3=10/Mechanical,2=130/0-3-8,4=-0/MechanicaI Max Horz 2=41 (LC 12) Max Uplift 3=-7(LC 12),2 58(1_C 12) Max Grav 3=10(LC 19), 2=130(LC 1), 4=12(LC 3) FORCES. (lb) - Max. Comp./Max. Ten, - All forces 250 (lb) or less except when shown. Scale = 1 7,0 2x4 = DEFL. in (loc) War! L/d PLATES GRIP Verl(LL) -0.00 5 >999 240 MT20 244/190 Vert(CT) -0.00 7 >999 180 Horz(CT) 0.00 2 n/a n/a Weight: 5 lb FT = 20% BRACING - TOP CHORD Structural wood sheathing directly applied or 1-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0.0 oc; bracing. NOTES- 1) Wind: ASCE 7-10; Vult=140mph (3-second gust) Vasd=108mph: TCDL=4,2psf, BCDL=3.Opsf, h=25ft; Cat. III Exp 8, Encl., GCpi=0.18, MV,/FRS (envelope) gable end zone and C-C Exterior(2) zone,C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 par bottom Chord live load nonconcurrent with any other live loads, 3) * This truss has been designed for a live load of 20,Opsf on the bottom chord in all areas where a rectangle 3-" tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3, 2. This item has been electronically signed and sealed by Albani, Thomas, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on, any Qlectronic cor ,jes. 0 February 23,2018 A WARNING, Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 1"312015 BEFORE USE. Design valid for use only with MtTekID connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use. the building designer must verity the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web andlor chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the If. fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIrnsil Quality Criteria, OS849 and BCSI Building Component 6904 Parke East Blvd. Safety information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314, Tampa..Fl, 36610 0' Truss TypeType'y PlyS" 7§undanZ 1730-A Ti P,73oA CJ3 JACK Mid -Florida Lumber, Barlow, FL. 8.130 s Sep 15 2017 MiTek Industries, Inc. Fri Feb 23 13:14:26 2018 Page I ID:3zzrE5595qHBqKdROwR6OYzkwee-ZobCbXlul59Lsl5gOTRDuci1Xav?Hhy7pqEZglziF5h 1" 1-0-0 3-0-0 Scale 1"=I* 416 2x4 = LOADING (pst) SPACING- 2-0-0 CSI. TCLL 20.0 Plate Grip DOL 1.25 TC 0.09 TCDL 10.0 Lumber DOL 1.25 BC 0.08 BCLL 0.0 Rep Stress Incr YES WB 0.00 BCDL 10.0 Code FBC2017ITP12014 Matrix -MP LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 REACTIONS. (lb/size) 3=71 /Mechanical, 2=1 88/0-3-8, 4=36/Mechaniral Max Horz 2=85(LC 12) Max Uplift 3=52(]_C 12), 2-64(LC 12), 4=-4(LC 12) Max Grav 3=71(LC 1), 2=188(LC 1), 4=52(LC 3) FORCES. (lb) -Max. Comp./Max. Ten, -All forces 250 (lb) or less except when shown. DEFL. in (loc) I/defl L/d PLATES GRIP Vefl(LL) -0.00 4-7 >999 240 MT20 244/190 Vert(CT) 401 4-7 >999 180 Horz(CT) 400 3 n1a n/a Weight: 11 lb FT = 20% BRACING - TOP CHORD Structural wood sheathing directly applied or 3.0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. NOTES- 1) Wind: ASCE 7-10. Vuh=140mph (3-second gust) Vasd=108mph; TCDL=4.2psf, BCDL=3.Opsf, h=25ft, Cat. 11, Exp B; Encl., GCpi=0.18, MWFRS (envelope) gable end zone and C-C Exterior(2) -1-0-0 to 2-0-0, Interior(l) 2-0-0 to 2-11-4 zone,C-C for members and forces & MWFRS for reactions shown, Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate Capable of withstanding 100 lb uplift at joint(s) 3, 2, 4. This item has been electronically signed and sealed by Albani, Thomas, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified cinany ,electronic copies. TKornas'A:A1bini'PENO_'3" 0 ek, SAJ 0.1 Cort6f 6904 February 23,2018 WARNING - Verity design par —tees and READ NOTES ON THIS AND INCLUDED ANITEK REFERENCE PAGE IWI-7473 rev. 1"312015 BEFORE USE, Design valid for use only with MiTelkV connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use. the building designer must venty the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web andlor chord members only. Additi0ruil temporary and permanent bracing Is always required for stability and to prevent collapse with possible personal injury and properly damage. For general guidance regarding the 10-11fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSVrPJl Quality Criteria, DSB-89 and SCSI Building Component 6904 Parke Fast Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314, Tempe, FL 36610 Job Truss T urmsTypeQryPlyParkSq/ Sundance-1730-A P1730A CJ5 JACK 14 1 T13325053 o0 R ren4g (4 tii—h Mid -Florida Lumber, Bartow, FL. 8.130 s Sep 15 2017 MiTek Industries, Inc. Fri Feb 23 13:14:26 2018 Page 1 ID:3zzrE 5595gHBgKdROwR6OYzkwee-ZobCbXlul59Lsl 5gOTRDucizwaS6Hhy7pgEZglziF5h F---- .1-0-4 -- -r - 5-0-0 ._..._._. . 1-0-0 5-0-0 Scale = 1:17.3 col 2x4 t n_n LOADING (psf} SPACING- 2-0 0 CSI. DEFL. in (loc) Ifdefl Lid TCLL 20.0 Plate Grip DOL 1.25 TC 0.32 Vert(LL) 0,04 4-7 >999 240 TCQL 10.0 Lumber DOL 1.25 BC 0.26 Vert(CT) -0.06 4-7 >988 180 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 3 nla n/a BCQL 10.0 Cade FBC2017frP12014 Matrix -MP LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 REACTIONS. (lb/size) 3=127/Mechanical, 2=26410-3-8. 4=64/Mechanical Max Horz 2=130(LC 12) Max Uplift 3=-94(LC 12), 2=-80(LC 12), 4=-6(LC 12) Max Grav 3=127(LC 1), 2=264(LC 1), 4=91(LC 3) FORCES. ( lb) -Max. Comp./Max, Ten. -All forces 250 (lb) or less except when shown. PLATES GRIP MT20 2441190 Weight 18 lb FT = 20% BRACING - TOP CHORD Structural wood sheathing directly applied or 5-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. NOTES- 1) Wind: ASCE 7-10; VuR=140mph (3-second gust) Vasd=108mph; TCDL=4.2psf, BCDL=3.Opsf; h=25ff; Cat. II; Exp B; Encl., W GCpi=0.18; MFRS (envelope) gable end zone and C-C Exterior(2) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 4-11-4 zone;C-C for members and forces 8 MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3, 2, 4. This item has been electronically signed and sealed by Albani, Thomas, PE using a Digital Signature. Printed copies Of this document are not considered signed and sealed and the signature must be verified on , pity glectronic copies. ThomasAA)bani fE No.3 3' 0C 410SSAIrtc' k"6"q 6904 pa4£ tF i S361A February 23, 2018 A WARNING • Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE M11•7473 rev. 10/03/2015 BEFORE USE. Design valid for use only with MiTekQp connectors. This design is based only upon parameters shown, and is for an individual building component. not a truss system. Before use, the building designer must verity the applicability of design parameters and properly incorporate this design mto the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing "04 is alwaysrequired (or stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIrTP11 Quality Criteria, DS6-89 and SCSI Building Component 6904 Parke East Blvd, Safety Information available from Truss Plate Instdute, 218 N. Lee Street, Suite 312. Alexandria, VA 22314, Tampa FL 36610 Job Truss Truss Type Park Sq/ Sundance-1730-A P1730A F1 ROOF T U, S, SROOFTRUSS Pty 3 131 T133250543 Id -Florida Lumber, Bartow, fL. 8.130 s Sep 15 2017 MiTek Industries, Inc. Fri Feb 23 13:14:28 2018 Page I ID:3z2rE5595qHBqKdROwR6OYzkwee-VBiy0DK8qiP36KF2WuThzlnCUO-qlSgQH8iglBziF5f 0-1-8 H 0-0Sca1e 1'50'o 4x4 = 3x4 1XI = 10 1x3 = I x3 3x6 FP = 4x4 = 4x8 = 3x4 = I X3 II 1x3 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 4 36 3 35 32 31 30 29 28 27 26 25 24 23 2221 20 19 18 17 16 1 X3 11 4X4 1 X3 11 04 = 4X6 = 4x6 = 3x6 FP == lx3 11 3x4 = lx3 11 3x4 Q 4 Plate Offs -1:eXY)--_Al Egge 0 o -8 Ed LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (loc) I/defI L/d TCLL 40.0 Plate Grip DOL L00 TC 0.83 Vert(LL) -0.15 29-30 -999 360 TCDL 10.0 Lumber DOL 1.00 BC 0.95 Vert(CT) -0.20 29-30 >973 240 8CLL 0.0 Rep Stress Incr YES VVB 0.63 Horz(CT) 0.04 16 n/a n/a BCDL 5.0 Code FBC2017fTP12014 Matrix-S LUMBER- BRACING - PLATES GRIP MT20 244/190 Weight: 152 lb FT = 20%F, 11 %E TOP CHORD 2x4 SP No.2(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, BOT CHORD 2x4 SP No.2(flat) *Except* except end verticals. 16-22: 2x4 SP No. 1 (flat) BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. WEBS 2x4 SP No.3(flat) *Except* 1-32,15-16: 2x4 SP No,2(flat) REACTIONS, (lb/size) 32=75010-8-0,16=577/0-8-0,24=1918/0-8-0 Max Gray 32=779(LC 3),16=660(LC 4), 24=1 918(LC 1) FORCES, (lb) - Max. Comp./Max, Ten, - All forces 250 (lb) or less except when shown. TOP CHORD 1-32=-77310, 15-16=-651/0, 1-2=72910, 2-3=1 775/0, 3-4=2253/0' 4-5=-2253/0, 5-7=-1939/0, 7-8--1068171, 8-9=0/811, 9-10=011049, 10-1 1=-1049/537, 11-12=-1543/212, 12-13=-1543/212, 13-14=1415/0, 14-15=-596/0 BOT CHORD 30-31=0/1405, 29-30=0/2112, 28-29=0/2253, 27-28=0/2253, 26-27=0/1631, 25-26=-283/475, 24-25=-1 75110, 23-24=-1 751/0, 21-23-792/626, 20-21-212/1543, 19-20=-212/1543, 18-19=-1011610,17-18=011155 WEBS 9-24=-1 889/0, 1-31 =0/991, 2-31--94010, 2-30-0/515, 3-30=-469/0, 3-29=-1 22/337, 15-17=0/810, 9-23=011 124,14-17=-778/0,10-23--1032/0,14-18--21/362,10-21 =01730, 13-18=-272/116,11-21=-888/0,13-19=-420/0,11-20-0/293, 9-25=0/1313,8-25=-1237/0, 8-26=01873, 7-26=-82710, 7-27=0/499, 5-27=-612/0 NOTES- 1) Unbalanced floor live loads have been considered for this design, 2) All plates are 3x3 MT20 unless otherwise indicated. This item has been3) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc; and fastened to each truss with 3-10d (0. 131 X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. electronically signed and 4) CAUTION, Do not erect truss backwards. sealed by Albani, Thomas, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified qn,pQy,i,lectronic copies. Thomas 'A:'Alb4niPENG 393 0 sk SA,11 Carl,$$ 6904 ;33 1 February 23,2018 WARNIMr- Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 11111-7473 rov. 1010312015 BEFORE USE Design valid for use only with MtTelke) connectors. This design is based only upon parameters $hown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design into the overall building design, Bracing indicated is to prevent buckling of individual truss web and/or chord members only, Additional temporary and permanent bracing is alvivays required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication storage..delivery, erection and bracing of trusses and truss systems see ANSIITP11 Quality Criteria, DSB-89 and SCSI Building Component 6904 Parke East Blvd, Safety Information available from Truss Plate Institute, 218 N. Lee Street. Suite 312, Alexandria VA 22314. Tampa, Ft- 36610 JOb Truss Truss Type Ory Ply Park Sqt Sundanee-1730-A LP1730A F1A GABLE_ 1 1 Tt3325055 qb Rgjesgr r yoptional{ _ _ Mid -Florida Lumber, Bartow, FL. 8.130 s Sep 15 2017 MiTek Industries, Inc. Fri Feb 23 13:14:29 2018 Page 1 ID:3zzrE5595gHBgKdROwR6OYzkwee-zNGKEZLmbOYvAUgF3b wWFKYWoYhU2AaVoTDHdziF5e 0-k8 0-k8 Scale: 1 /4"- l' 3x6 FP 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 ZZE - Ta24LLJ51Lid48 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33 32 31 30 29 28 27 26 25 3x6 FP 10- 11.4 10• 10a14 12-3-4 20--5.4 26- 11-4 i T2"{ a o a?a e ona3o0oai424-&42s^ 7.4 4 Pt 21 a I z ia8 12i.a a a6-4-0o-sa o m1a•g suss-l-la LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) Well L/d PLATES GRIP TCLL 40. 0 Plate Grip DOL 1.00 TC 0.11 Vert(L-) n/a n/a 999 MT20 244/190 TCDL 10. 0 Lumber DOL 1.00 BC 0.01 Vert(CT) n/a n/a 999 BCLL 0. 0 Rep Stress Incr YES WB 0,03 Horz(CT) 0.00 25 n/a n/a BCDL 5. 0 Code FBC2017/7PI2014 Matrix-R Weight: 127 lb FT = 20%F, 11 %E LUMBER- BRACING - TOP CHORD 2x4 SP No.2(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purtins, BOT CHORD 2x4 SP No.2(flat) except end verticals. WEBS 2x4 SP No.3(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. OTHERS 2x4 SP No.3(flat) REACTIONS. All bearings 29-10-8. lb) - Max Grav All reactions 250 lb or less at joint(s) 48, 25, 37. 38, 39, 40, 41, 42, 43, 44, 45, 46, 47, 36, 35, 34, 32, 31, 30, 29, 28, 27, 26 FORCES. (lb) - Max. Comp,/Max. Ten. -All forces 250 (lb) or less except when shown. NOTES- 1) All plates are 1 x3 MT20 unless otherwise indicated. 2) Gable requires continuous bottom chord bearing. 3) Truss to be fully sheathed from one face or securely braced against lateral movement i.e. diagonal web). 4) Gable studs spaced at 1-4-0 oc. 5) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-1 Od (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 6) CAUTION, Do not erect truss backwards, This item has been electronically signed and sealed by Albani, Thomas, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on„any electronic copes. Thomas A Atb4OPE No.393 cog lililIYakt1Sa, Inc.-OL ton se , 9ti4 Rark Ea°st"6tv`c1. T 338ta f+ February 23, 2018 WARNING - Verify design parameters end READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MIl•7473 rev. 10/03/2015 BEFORE USE, Design valid for use only with MiTeM connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verity the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual mass web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the put,. rebricat ion. storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 Quality Criteria, OSB•89 and BCSI Building Component 6904 Parke East Blvd, Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314, Tampa, FL 36610 i0, Trus s IiType mm dty Plyark Sq/ Sundance-1730-A p1F2 OF TRUSS I T13325056 Mid-Flonda Lumber, Bartow, FL, 8,130 s Sep 15 2017 MiTek Industries, Inc, Fn Feb 23 13 14 30 2018 Page 1 ID:3zzrE5595qHBqKdROwR6OYzkwee-RZqjRvMOMKgnLePRdl\ 193SsZ2BfODLlikScmp3ziF5d 0-1-8 H 1-- Scale = 1 43. 1 32 31 04 lx3 = 4X6 14 = 3x4 = 04 = 34 FP = 3x4 = 4x4 = 3x6 1 2 3 4 5 6 7 8 9 10 11 12 13 14 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 1,5x4 li 4x6 = 3x4 = 3x8 MT20HS FP = i X3 11 1 X3 If 4x4 = 4X6 = 3x10 = 1.5X4 il lx3 11 4x4 1,5x4 SP = eiq!e ffsets( X,YI-- (1-Egge -1-8 12*.Q:1-8. P-LL13-9--lz-8-Ed-g-ej---- LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (loc) I/defl LId PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.76 Vert(LL) -0.30 24-25 >799 360 MT20 244/190 TCDL 10.0 Lumber DOE 1.00 BC 0.97 Ven(CT) -0.42 24-25 >583 240 MT20HS 1871143 BCLL 0.0 Rep Stress Incr YES WB 0.68 Horz(CT) 0.06 19 Ilia n/a BCDL 5.0 Code FBC2017rrPI2014 Matrix-S Weight: 136 lb FT = 20%F, 11 %E LUMBER- BRACING - TOP CHORD 2x4 SP No.2(flat) *Except* TOP CHORD Structural wood sheathing directly applied or 4-8-7 oc purlins, 9-14: 2x4 SP DSS(flat) except end verticals. BOT CHORD 2x4 SP No.2(flat) *Except* BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. 15-26: 2x4 SP No.10(flat) WEBS 2x4 SP No,3(flat) REACTIONS. (IbIsize) 30= 975/0-8-0,15=-25310-3-8,19=2079/0-3-8 Max Uplift 15=- 483(LC 3) Max Grav 30= 977(LC 10), 15=160(LC 4),19=2079(LC 1) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1- 30=-971/0, 14-15=-168/456, 1-2=-94310, 2-3=-2399/0, 3-4=-326310, 4-5=-3552/0, 5-6-3440/ 0, 6-7=-291810, 7-8=-1 795/0, 10-11 =012474, 11-12=0/2474, 12-13=0/1 396, 13-14-451592 BOT CHORD 28-29=0/ 1821, 27-28=0/2949, 25-27=013559, 24-25=013440, 23-24=0/3440, 22-23=013440, 21-22=012480, 20-21= 0/1079, 19-20=-1074/0, 18-19=-1396/0, 17-18=-139610, 16-17=-1396/0 WEBS 1-29=0/1282, 10-19=-1872/0,2-29-1221/0, 10-20=0/1431, 2-28=0/804, 8-20=-1378/0, 3-28=-765/0,8- 21=011010,3-27=0/437,7-21=-966/0,4-27-412/0,7-22=01634, 6-22=-811/0, 5- 25-241/392, 5-24=-329/80, 6-23=-61/350, 14-16=-789/60, 12-19=-1618/0,13- 16=0/1093, 12-18=0/545, 13-17=-569/0 NOTES- 1) Unbalanced floor live loads have been considered for this design. 2) All plates are MT20 plates unless otherwise indicated. 3) All plates are 3x3 MT20 unless otherwise indicated, 4) The Fabrication Tolerance at joint 26 = 11 % 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 483 lb uplift at joint 15. 6) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-1 Od (0. 131 " X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 7) CAUTION, Do not erect truss backwards. A WARNING - Verity design parameters and READ NOTES ON THIS AND INCLUDED AgTEK REFERENCE PAGE IWX 7473 rev, 1010312015 BEFORE USE. Oesitir, valid for use only with MiTek(k) connectors, This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must venty the applicability of design parameters and property incorporate this design into the overall building (resign, bracing indicated is to prevent buckling of individual truss web and/or chord members only, Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and properly damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems. see ANSVTPIl Quality Crtteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Sufle 312, Alexandra, VA 22314, This item has been electronically signed and sealed by Albani, Thomas, PE using a Digital Signature, Printed copies of this document are not considered signed and sealed and the signature must be verified qn, any ,lectronic copes. 0 6904 Piilkti!9'1§ 14 - Na Al"IC1336 to February 23,2018 m i " 6904 Parke East Blvd, Tampa, FL 36610 Job Tn ss Truss Type Oty Pty Park Sq/ Sundance- 1 730-A T13325057 P1730A F2A ROOF TRUSS 1 1 Mid -Florida Lumber, Bartow, FL. 8.130 s Sep 15 2017 MiTek Industries, Inc. Fn Feb 23 13:14:31 2018 Page 1 I D:3zzrE5595gHBgKdROwR6OYzkwee-vmO5eFM 16doezo_dB00ObgPjxb?nylBsz6yKM WZIF5C 0-1-8 fi 1) 3-o 1f---7=-- I 0i,a--T Scale =, 43.2 4x4 = tx3 = 4x6= ix3 = 3x4 = 3x3 = 3x3 = 3x3 = 3x3 == 3x4 = 3x6 FP = 4x6 = 6x6 = 4x6 = 3x6 1 2 3 4 5 6 7 8 9 10 11 12 13 17 28 27 26 25 24 23 22 21 20 19 18 17 16 i5 14 1.5x4 11 4x6 = 3x4 = 3x8 MT20HS FP = ix3 II 1.5x4 11 3x4 = 4x6 = 4x6 = 4x8 = 44 = 3x3 11 1.5x4 SP = 3x3 = 6x6 = 3x3 = 21-0-1.2 25-8-4 LOADING (psf) SPACING- 2-0-0 CSI. DE(FILL) in (loc) I/defl L/d PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.82 Vert(LL) -0.31 22-23 >812 360 MT20 244/190 TCDL 10.0 Lumber DOL 1.00 BC 1.00 Vert(CT) -0.42 22-23 a591 240 MT20HS 187/143 BCLL 0.0 Rep Stress Incr NO WB 0.$3 Horz(CT) 0.05 17 We n/a BCDL 5.0 Code FBC2017/TP12014 Matrix-S Weight: 134 lb FT = 20%F, 11 of E LUMBER- BRACING - TOP CHORD 2x4 SP No. 1(flat) TOP CHORD Structural wood sheathing directly applied or 5-8-7 oc purlins, BOT CHORD 2x4 SP No.2(flat) 'Except" except end verticals. 14-24: 2x4 SP DSS(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except: WEBS 2x4 SP No.3(flat) 6-0-0 oc bracing: 17-18,16-17,15-16. REACTIONS. (lb/size) 28=946/0-3-8, 14=-25715-5-0, 17=4771/5-5-0, 15=-479/5-5-0, 16=-415/5-5-0 Max Uplift 14=-257(LC 1), 15=-479(LC 1), 16=-415(1-C 1) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-28-940/0, 13-14=0/259, 1-2=-910/0, 2-3=-2302/0, 3.4=-3104/0, 4-5=3326/0, 5-6 =-3095/0, 6-7=-2380/0, 7-8=-1066/0, 8.10=0/837, 10-11=0/3363, 11-12=0/2499, 12-13=0/416 BOT CHORD 26-27=0/1757, 25-26=0/2817, 23-25=013379, 22-23=0/3095, 21-22=0/3095, 20-21=0/3095, 19-20=0/1831, 18-19=0/254, 17-18=-193410, 16-17=-3363/0, 15-16=-1317/0 WEBS 11-17=-3432/ 0, 1-27=0/1236, 10-17=-1903/0, 2-27=-1 178/0,10.18=0/1526, 2-26=0/759, 8-18=-1517/0, 3-26=-717/0, 8-19=0/1130, 3-25=0/398, 7-19=-1063/0, 4-25=-383/0, 7-20=0/765, 6-20=-1024/0, 5-23=-154/503, 5-22=386110, 6-21=0/414, 13-15=-554/0, 12-15=0/1252, 12-16=-1644/0, 11-16=0/1749 NOTES- 1) Unbalanced floor live loads have been considered for this design. 2) All plates are MT20 plates unless otherwise indicated. 3) The Fabrication Tolerance at joint 24 = 11% 4) Provide mechanical connection ( by others) of truss to bearing plate capable of withstanding 257 lb uplift at joint 14, 479 lb uplift at joint 15 and 415 lb uplift at joint 16, 5) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-1 Od (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 6) CAUTION, Do not erect truss backwards. LOAD CASE(S) Standard 1) Dead + Floor Live ( balanced): Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 14-28=-10, 1-13=-100 Concentrated Loads (lb) Vert: 11=1775 AWARNfNG - V®rify design parameters and READ NOTES ON THIS AND INCLUDED M(TEK REFERENCE PAGE U11,7473 rev. 1010312015 BEFORE USE. Design valid for use only with WelrO connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system_ Before use, the building designer must verify the applicability of design parameters and property incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage. delivery, erection and bracing of trusses and truss systems, see ANS11TP11 Quality Criteria, OSB-89 and BCSI Building Component safety information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria. VA 22314, This item has been electronically signed and sealed by Albani, Thomas, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified or), pny t,lectronic coOes. ThomasA Alb*PEtNtOU 0 Ml'ak t)SA, Irtc L Cert 66 6984 ParkO1't9 H6yd ' I INi 3961A February 23,2018 MI6904 Parke East Blvd, Tampa.. FL 36610 Park Sq/ Sundance-1730-AJot) Truss Type IyTrussCity P T13325058 F, P17-10A F3 ROOFTRUSS 3 f Tsin pA7____JJ9P_R" __qtJgpllk?_ Mid -Florida Lumber, Barlow, FL. 8.130 s Sep 15 2017 MiTek Industries, Inc. Fri Feb 23 13:14:32 2018 Page I I D:3zzrE 5595q H Bq Kd ROwR6OYzkwee-NyyTsbNftxwVayZplj Xd8tyvm?MghFYOBmhtuyziF5b 0-1-8 H Scale - 1 42.5 32 31 4x4 lx3 = 4x6 1x3 = 3x4 = 4X4 = 3x6 PP = 3x4 =4x4 1 2 3 4 5 6 7 8 9 10 11 12 13 3x6 14 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 1.5x4 11 4x6 = 3x4 = 3x8 MT20HS FP = 1x3 11 10 11 4X4 = 4X6 = 4XII = 2X4 11 4X6 1.5x4 SP = 1x3 11 LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (loc) Well L/d TCLL 40,0 Plate Grip DOL 1.00 TC 0.75 Verl(LL) 0.29 24-25 851 360 TCDL 10.0 Lumber DOL 1.00 BC 0.95 Vert(CT) 0.39 24-25 620 240 BCLL 0.0 Rep Stress Incr YES WB 030 Horz(CT) 0.05 19 n/a n/a BCDL 5.0 Code FBC2017rrPt2014 Matrix-S LUMBER- BRACING - TOP CHORD 2X4 SP No.2(at) *Except* TOP CHORD 9-14: 2x4 SP DSS(flat) BOT CHORD 2x4 SP No.2(flat) *Except* BOT CHORD 15-26: 2x4 SP No. 1 D(flat) WEBS 2x4 SP No.3(flat) REACTIONS. (lb/size) 30=947/0-8-0,15=-42310-3-8,19-2239/0-3-8 Max Uplift 15=632(1_C 3) Max Grav 30=949(LC 10), 15=93(LC 4), 19=2239(LC 1) FORCES. (lb) - Max. Comp./Max. Ten, - All forces 250 (lb) or less except when shown. TOP CHORD 1-30=-943/0, 14-15--1001609,1-2=-913/0.2-3--2311/0, 3-4=-3117/0,4-5=-3348/0, 5-6-3192/0, 15-7-262610, 7-8-1445A 8-10=0/413, 10-1 1=0/2884,11-12-0/2884, 12-13=0/1692, 13-14=0/758 BOT CHORD 28-29=0/1 762, 27-28=0/2831, 25-27=013386. 24-25=0/3192, 23-24=0/3192, 22-23=013192, 21-22=0/2157, 20-21 =01700,19-20=-1 466/0,18-19=-1692/0, 17-1 8=-1692/0, 16-17=-1692/0 WEBS 1-29=011240, 10-19=-1899/0, 2-29=-1181/0, 10-20=0/1464, 2-28=0/764, 8-20=-1417/0, 3-28-72410, 8-2 1 =0/1 047, 3-27=0/397, 7-21 =-999/0, 4-27=-37410, 7-22-0/662, 6-22=-850/0, 5-25=-197/431, 5-24-348/60, 6-23=-401368, 14-16=-100910, 12-19=1766/0,13-16=0/1270,12-18=0/628,13-17=-654/0 PLATES GRIP MT20 2441190 MT20HS 187/143 Weight: 135 lb FT = 20%F, 1 1%E Structural wood sheathing directly applied or 4-10-14 oc puffins, except end verticals. Rigid ceiling directly applied or 2-2-0 oc bracing. NOTES. 1) Unbalanced floor live loads have been considered for this design. 2) All plates are MT20 plates unless otherwise indicated. 3) All plates are 3x3 MT20 unless otherwise indicated, 4) The Fabrication Tolerance at joint 26 = 11 % 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 632 lb uplift at joint 15. 6) Recommend 2x6 strongbacks, an edge, spaced at 10-0-0 oc; and fastened to each truss with 3-1 Old (0, 131 " X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 7) CAUTION, Do not erect truss backwards. WARNING - Verify d-itin parameters and READ NOTES ON THIS AND INCLUDED UfTEK REFERENCE PAGE 111,111-7473nev. 10/03,2015 BEFORE USE. Design valid for use only with MiTek(P connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web anchor chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSVTPII Quality Criteria, DS"S and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandna, VA 22314, This item has been electronically signed and sealed by Albani, Thomas, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified cin,prly,tlectronic copies. Thomas PE -ND 393 0, 17 60M Park f sfBiud A '-1361V February 23,2018 146-aw 6904 Parke East Blvd, Tampa. FL 36610 ob 5S IsTruss Type QtyQ Ply Park Sq/ Sundance-I 730-A T13325059 P IL130A TRUSSFlRrOFTTRU., 7 I : F I Mid -Florida Lumber, Bartow, FL. rtnRde 8.130 s Sep 15 2017 MiTek Industries, Inc. Fri Feb 23 13:14:33 2018 Page 1 ID:3z.zrE5595qHbqKdROwR6OYzkwee-s8Wr3wOHeF2LC680IR3sg5UOjPl3QhD9QQRQQOziF5a 0-1-8 H Scale = 1 34,8 4x6 Ixa = lx3 = 4x4 = 1 x3 II 1 2 3 4 5 6 7 1 5 4 34 FP= 4Y4 = 4x6 9 10 11 1.5X4 It 4X6 = 3x8MT18HSFP = lx3 It 4X4 = 4X6 04 LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (loc) I/defl Lld TCLL 40,0 Plate Grip DOL 1.00 TC 0.93 Vert(LL) -0.41 lr.17 -607 360 TCDL 100 o Lumber DOL I .00 BC 0.69 Vert(CT) -0.56 16-17 >443 240 8CLL (,,Rep Stress Incr YES WiB 0.73 Horz(CT) 0.08 12 n/a n/a BCDL 5.0 Code FBC2017rTP12014 Matrix-s LUMBER- BRACING - TOP CHORD 2x4 SP No.2(flat) TOP CHORD BOT CHORD 2x4 SP No. 1 (flat) *Except* 12-20: 2x4 SP DSS(flat) BOT CHORD WEBS 2x4 SP No.3(flat) REACTIONS, (lb/size) 23=1131/0-8-0, 12-113110-8-0 FORCES. (lb) - Max. Comp.tMax. Ten. - All forces 250 (lb) or less except when shown, TOP CHORD 1-23=11 124/0,11-12=-1 123/0, 1-2=-1 108/0, 2-3-288710, 3-4=-4047/0, 4-5=-4768/0, 5-6=476810.6-7=- 4679/0,7-8=4084/0,8-10=-2920/0, 10-11=-1158/0 BOTCHORD 21-22=0/2144, 19-21=013596,18-19=0/4495,17-18=0/4768,16-17=0/4768,15-16=0/4526, 14-15=013621, 13-14= 0/2191 WEBS 11-13=0/1541, 1-22=011506,10-13=-1436/0,2-22=-1442/0,10-14=011014,2-21=0/1033, 8-14=-976/0, 3- 21 =-987/0, 8-15=01644, 3-19=0/627, 7-115=-615/0, 4-19=-624/0, 7-16=-27/397, 4- 18=-85/671, 6-16=-468/234 PLATES GRIP MT20 244/190 MT18HS 2441190 Weight: 108 lb FT = 20% F, 11 %E Structural wood sheathing directly applied or 2-2-0 oc purlins, except end verticals. Rigid ceiling directly applied or 10-0-0 oc bracing. NOTES- 1) Unbalanced floor live loads have been considered for this design. 2) All plates are MT20 plates unless otherwise indicated, 3) All plates are 3x3 MT20 unless otherwise indicated. 4) Recommend 2x6 strongbac*s, on edge, spaced at 10-0-0 oc and fastened to each truss with 3- 1 Od (0. 13 1 " X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means, 5) CAUTION, Do not erect truss backwards. This item has been electronically signed and sealed by Albani, Thomas, PE using a Digital Signature, Printed copies of this document are not considered signed and sealed and the signature must be verified gn,, pQy electronic Copies. February 23,2018 A WARNING - Verify design par — Mrs and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mil-7473 —.1010312015 BEFORE USE Resign valid for use only with MiTelolv contractors, This design IS based only upon parameters shown, and is for an individual building component, not a truss system Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss wet) and/or chord members only, Additional temporary and permanent bracing Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the - fabrication. storage, delivery, erection and bracing of trusses and truss systems, see ANSIrTPl1 Quality Criteria, DS8.89 and BCSI Building Component 6904 Parke East Blvd, Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 T— - S--T -- — ] ITrui - — — — - — --------------- ------------------ JQty Ply Park Sq/ SundanceTruss "u e Ply P "" Sq S -1730-ATrussJob T13325060 P, P17-30A F5 ROOF TRUSS 1JR-0 B fLRefe' Mid -Florida Lumber, Bartow, FL. 8.130 s Sep 15 2017 MiTek Industries, Inc. Fn Feb 23 13:14:34 2018 Page I ID:3zzrE5595qHBqKdROwR6OYzkwee-KK3DHGPvPYACqFiCs8a5DIID_pOf97pJf4A-ZrziF57 0-1.8 H F i OF 9=1 z fScale - 1 33.8 1 5 4 4X6 1X3 — 1X3 = 4X4 = 1.3 11 3X6 FP= 4x4 = 4X6 1 2 3 4 5 6 7 8 9 10 11 1,5x4 11 4x6 = 3x8 MT20HS FP 1.5x4 SP 4X4 = i x3 11 LOADING (psf) SPACING- 02- 1.00 TC 0 83 Vert(U-) 1111, OEFL. in floc) I/defl L/d TCLL 40,0 Plate Grip DOI -0.38 167-17 >625 360 TCDL 10.0 Lumber DOL 1.00 BC 0.99 Vert(CT) -0.53 16-17 >456 240 BCLL 0.0 Rep Stress Incr YES VVI3 0.71 Horz(CT) 0.09 12 n1a n/a BCDL 5.0 Code FBC2017rTP12014 Matrix-S LUMBER- BRACING - TOP CHORD 2x4 SP No,2(flat) TOP CHORD BOT CHORD 2x4 SP No.2(flat) *Except* 12- 20: 2x4 SP No.i(flat) BOT CHORD WEBS 2x4 SP No,3(flat) REACTIONS. ( lb/size) 23= 1100/0-7-4, 12-11 OO/Mechaniral FORCES. ( lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-23=-1093/0, 11-12--1093/0,1-2=-1075/0,2-3=278910,3-4=-3889/0,4-5=-452210, 5- 6>4522/0, 6-7=-4453/0, 7-8=-3922/0, 8-10=-2821/0, 10-11=-1123/0 BOT CHORD 21-22=0/2079, 19-21=0/3468, 18-19=0/4301, 17-18=0/4522, 16-17=0/4522'115-116=0/4331' 14-15= 0/3491, 13-14=0/2124 WEBS 11- 13=0/1495,1-22=011461,10-13=-1 392/0, 2-22=-1397/0,10-14=0/970, 2-21 =0/988, 8-14=- 93210, 3-21=-945/0, 8-15-01599, 3-19=0/586, 7-15=-569/0, 4-19=-572/0, 7-16=- 701352, 4-18=-1 17/569, 6-16-385/220 4x4 = 4X6 PLATES GRIP MT20 244/ 190 MT20HS 1871143 Weight 106 lb FT = 20%F, 11 %E Structural wood sheathing directly applied or 2-2-0 oc purlins, except end verticals. Rigid ceiling directly applied or 10-0-0 oc bracing, Except: 2-2- 0 oc bracing: 19-21,17-18,16-17. NOTES- 1) Unbalanced floor live loads have been considered for this design. 2) All plates are MT20 plates unless otherwise indicated. 3) All plates are 3x3 MT20 unless Otherwise indicated. 4) The Fabrication Tolerance at joint 20 = 11 % 5) Refer to girder(s) for truss to truss connections, 6) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 7) CAUTION, Do not erect truss backwards, WARNING • Verify dififf. P...et— ..d READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 11,1167473,ev. 10/03/201.5 BEFORE USE. Design valid for use only with MfTekr@ connectors, This design is based only upon Parameters Shown, and is for an individual building component, not a muss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSVTPtl Quality Criteria, DS5419 and BCSI Building Component S, rely information available from Truss Plate Institute 218 N Lee Street, Suite 312, Alexandria, VA 22314, This item has been electronically signed and sealed by Albani, Thomas, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified pn,pQy, electronic copies. Thomas* A1b; ini,,PE-NO"3V 0 00k,L) SAJf(c=10 on 6 l-'6904Park Z M1 February 23, 2018 Fal 6904 Parke East Blvd, Tampa, FL 36610 Job Truss Truss Type F city IPIy Park Sq, Sundance-1730-A T13325061 P1730A F7 ROOF TRUSS t t S Eigfgr n o F a __ _ _ Mid -Florida Lumber, Bartow, FL. 8.130 s Sep 15 2017 MiTek Industries, Inc. Fri Feb 23 13:14:34 2018 Page 1 ID:3zzrE5595gHBgKd ROwR6OYzkwee-KK3DHGPvPYACgF)Cs8a5D1l JnpF6914Jf4A_uziF 5Z 01 8 Scale = 1:21.8 9 1x3 II 3 4 5 6 3x6 = 7 14 13 12 11 10 9 8 1x3 II LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ltd PLATES GRIP T CLL 40.0 Plate Grip DOL 1.00 TC 0.39 Vert(LL) n/a n/a 999 MT20 244/190 TCDL 10,0 Lumber DOL 1.00 BC 0.06 Vert(CT) n/a - n/a 999 BCLL 0.0 Rep Stress Incr YES WB 0.05 Horz(CT) 0,00 8 nfa n/a BCDL 5.0 Code FBC2017(TPI2014 Matrix-S Weight: 70 lb FT = 20°f%F, 11 %E LUMBER- BRACING - TOP CHORD 2x4 SP No.2(flat) TOP CHORD Structural wood sheathing directly applied or 10-0-0 oc purlins, BOT CHORD 2x4 SP No.2(flat) except end verticals. WEBS 2x4 SP No.3(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except: 6-0-0 oc bracing: 12-13,11-12. REACTIONS. All bearings 13-1-12, lb) - Max Grav All reactions 250 lb or less at joint(s) 15, 8, 9, 14, 13, 11, 12 except 10=303(LC 1) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. NOTES- 1) All plates are 3x3 MT20 unless otherwise indicated. 2) Gable requires continuous bottom chord bearing. 3) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 4) CAUTION, Do not erect truss backwards. This item has been electronically signed and sealed by Albani, Thomas, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on,any electronic copies. Thomas A AIb4ni PE`No383 4 M"Y,kkui4 igt"gtcerts*, 6$Eb4 Parks ES St"84v'.1a'`n'FI,361p; February 23,2018 A WARNING. Verlry design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII.7473 rev, 10/03/2015 BEFORE USE. Design valid for use only with Ii connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must veiny the applicability of design parameters and property incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing POW'is alwaysrequired for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems. see ANSIfrPit Quality Criteria, DS .89 and SCSI Building Component 6904 Parke East Blvd, Safety Information available from Truss Plate Institute, 218 N, Lee Street, Suite 312, Alexandria, VA 22314, Tampa, FL 36610 Job iTruss P1730A F8 Mid -Florida Lumber, Bartow, FL. 0-1-8 H 1 14 13 1x3 II Type Qty Pty Park Sq/ Sundance-1730-A 1 1 T13325062 TRUSS R_RoP._[j3Lal1 ____ 8.130 s Sep 15 2017 MiTek Industries, Inc. Fri Feb 23 13:14:35 2018 Page 1 I D:3zzrE5595gHBgKdROwR6OYzkwee-oXdbUcPXAsl3SPHOQs5KmWaUbCX?uhsSukwXVHziF5Y Scale = 1:17.1 1x3 II 1x3 II 2 3 4 5 3xe = 6 4 7 LOADING (psf) SPACING- 2-0-0 CSI. DEFL, in (loc) I/deft Ltd PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.39 Vert(LL) -0.02 8-9 >999 360 MT20 244/190 TCDL 10.0 Lumber DOL 1.00 BC 0,27 Vert(CT) -0.03 8-9 >999 240 SCLL 0.0 Rep Stress Incr YES WB 0.28 Horz(CT) 0.01 7 n/a n/a BCOL 5.0 Code FBC2017/TPI2014 Matrix-S Weight: 51 lb FT = 20%F, 11%E LUMBER- BRACING - TOP CHORD 2x4 SP No.2(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc puffins, BOT CHORD 2x4 SP No.2(flat) except end verticals. WEBS 2x4 SP No.3(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 12=49510-8-0, 7=495/Mechanical FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOR CHORD 1- 12=491/0, 6-7 =-491/0, 1-2=-419/0, 2-3=907/0, 3-4=907/0, 4-5=907/0, 5-6=-43610 BOT CHORD 10- 11=01794, 9-10=0/907, 8-9=0/808 WEBS 6-8=01580, 1- 11=0/569, Sm8=-518/0, 2-11=523/0, 5-9=-51263, 2-10=0/274 NOTES- 1) Unbalanced floor live loads have been considered for this design. 2) All plates are 3x3 MT20 unless otherwise indicated. 3) Refer to girder(s) for truss to truss connections. 4) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 5) CAUTION, Do not erect truss backwards. This item has been electronically signed and sealed by Albani, Thomas, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on,) ny glectronc copies. Thomas A NNW PE ND, 3". A9ilfek i)SA I o Cent 86 ' ?" b"994 Park$'Et Blvd. %" n 38t February 23,2018 A WARNING - Veri(y design perimeters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 11,4I1-7473 rev. IOM312015 BEFORE USE. Design valid for use only with MiTektti connectors. This design is based only upon parameters showm. and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design, Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing (4' ie;+ is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the !Yi t4 fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and SCSI Building Component 6904 Parke East Blvd. Safety ;on, available from Truss Plate Institute, 218 N, Lee Street, Suite 312, Alexandria, VA 22314. Tampa. FL 36610 Job Tnass Truss Type Qty T13325063 Pty Parkt Sundance-1730- AP1730AF9ROOFTRUSS 2 jjrgnce(ou Mid -Florida Lumber, Bartow, FL. 8.130 s Sep 15 2017 MiTek Industries, Inc. Fri Feb 23 13:14:36 2018 Page 1 ID:3zzrE5595gHBgKdROwR6OYzkwee-GjB_iyQ9xAQw3Zsb_ZcZlj6kfcxedBDc6Of51 jziF5X ix-0 3x6 1 3x6 = 2 3 1 x3 11 4 Scale = 1:9A 8 3x3 II 3x3 = 3x3 7 6 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in loc) I/defl Lid TCLL 40.0 Plate Grip DOL 1.00 TC 0.11 Vert(LL) -0.00 6 999 360 TCDL 10.0 Lumber DOL 1.00 BC 0.06 Vert(CT) -0.00 7 999 240 BCLL 0.0 Rep Stress Incr YES WB 0.08 Horz(CT) 0.00 5 n/a n/a BCDL 5.0 Code FBC2017/TPI2014 Matrix-S LUMBER- BRACING- 5 3x3 11 PLATES GRIP MT20 244/190 Weight: 24 lb FT = 20%F, 11 %E TOP CHORD 2x4 SP No.2(flat) TOP CHORD Structural wood sheathing directly applied or 3-4-0 oc purlins, BOT CHORD 2x4 SP No.2(flat) except end verticals. WEBS 2x4 SP No.3(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 Gc bracing. REACTIONS. (lb/size) 8=170/Mechanical, 5=170/Mechanical FORCES, (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES - I) Unbalanced floor live loads have been considered for this design. 2) Refer to girder(s) for truss to truss connections. 3) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0,131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. This item has been electronically signed and sealed by Albani, Thomas, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on.any electronic copies. Thomas A AlbjE i PE -,No $93 4 Mi'ekilSA Irtc<F Cart863 6a94Patk Ea sf"Blvd TiM" G33811J February 23,2018 A WARNING. Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE M11-7473 rev. 1010312015 BEFORE USE. Design valid for use only with Wake connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system, Before use, the building designer must vanity the applicability of design parameters and property incorporate this design into the overall building design. Bracing indicated is to prevent truckling of individual truss web and/or chord members only, Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage_ For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 Quality Criteria, OSR-89 and SCSI Building Component 6904 Parke East Blvd, Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314, Tampa,. FL 36610 Job Truss Truss Type Park Sq/ Sundance- 17i 0-A - T13325064 P1730A J3 JAGK 3 1 Qty ry PIY W rPnice 4p14f..______. Mid -Florida Lumber, Bartow, FL. 8.130 s Sep 15 2017 MiTek Industries, Inc. Fri Feb 23 13:14:36 2018 Page 1 ID:3zzrE5595gHBgKdROwR6OYzkwee-GjB_iyQ9xAQw3Zsb_Zczlj6kOcwLdCQc6Of51 jziF5X 1-0-0 Scale: 1"=1' 2x4 = LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (loc) Well L!d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.09 Vert(LL) -0.00 4-7 >999 240 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.08 Vert(CT) -0.01 4-7 >999 180 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 3 n/a n/a BCDL 10.0 Code FBC2017rrP12014 Matrix -MP Weiaht: 11 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 3-0-0 oc purlins. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 3=71/Mechanical, 2=188/0-8-0, 4=36/Mechanical Max Horz 2=85(LC 12) Max Uplift 3=-52(LC 12), 2--64(LC 12). 4=-4(LC 12) Max Grav 3=71(LC 1), 2=188(LC 1), 4=52(LC 3) FORCES. (lb) - Max. Comp./Max, Ten. - All forces 250 (lb) or less except when shown NOTES- 1) Wind: ASCE 7-10: Vult=140mph (3-second gust) Vasd=108mph; TCDL=4.2psf; BCDL=3.0psf, h=25ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope) gable end zone and C-C Exterior(2) -1-0-0 to 2-0-0. Intenor(1) 2-0-0 to 2-11-4 zone,C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10,0 psf bottom chord live load nonconcurrent with any other live loads. 3) " This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 52 lb uplift at joint 3, 64 lb uplift at joint 2 and 4 lb uplift at joint 4. This item has been electronically signed and sealed by Albani, Thomas, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on,;iny 0ectronic copies. PEThomasAA)b4ni N0.3 0 A9i'ek t SA, Inc,L Cart 66` 6904 RarlfftA'648'. 31i13&1,tk, February 23,2018 WARNING • Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 1101II-7473 rev. 10/03l2015 BEFORE USE. Design vatic[ for use only with MiTeM connectors. This design is based only upon parameters shown. and is for an individual building component, not a truss system. Before use, the building designer must venfy the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of busses and truss systems, see ANSIrrPl1 Quality Criteria, DSBA9 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Atexandna, VA 22314_ Tampa, FL 36610 P-1 ob Tr ss Truss Type T Oty Ply ParkSq/ Sundance-1730-A 730A J7 JACK 20 t T13325065 e[ C RG 149Sf.4.R Mid -Florida Lumber, Bartow, FL. 8.130 s Sep 15 2017 MiTek Industries, Inc. Fri Feb 23 13:14:39 2018 Page 1 ID:3zzrE5595gHBgKdROwR6OYzkwe"116K T2E5oVwlbAfh9HwMk6gggmgZA2pMule2ziF5U 1-DA _._....__.......... 7-0-0 1 0-0 7-0-0 Scale = 1.21.8 3x4 = LOADING (psis SPACING- 2-0-0 CSI. DEFL. in lot) Ildeft L/d TCLL 20.0 Plate Grip DOL 1.25 TC 0.70 Vert(LL) 0.14 4-7 580 240 TCDL 10.0 Lumber DOL 1_25 BC 0.54 Vert(CT) 0.24 4-7 348 180 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) 0,00 2 nta nta BCDL 10.0 Code FBC2017ITP12014 Matrix -MP LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 REACTIONS. (lb/size) 3=183/Mechanical, 2=342l0-3-8, 4=90lMechanical Max Horz 2=175(LC 12) Max Uplift 3=-135(LC 12), 2- 99(LC 12), 4=-8(LC 12) Max Grav 3=183(LC 1), 2=342(LC 1). 4=129(LC 3) FORCES. (lb) - Max. Comp,/Max, Ten, - All forces 250 (Ib) or less except when shown. PLATES GRIP MT20 2441190 Weight: 24 lb FT = 20% BRACING - TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc punins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. NOTES- 1) Wind: ASCE 7-10; Vuh=140mph (3-second gust) Vasd=108mph; TCDL=4,2psf; BCDL=3.Opsf; h=25ft; Cat. Q; Exp B; Encl., GCpi=0.18; MWFRS (envelope) gable end zone and C-C Exterior(2) -1-0-0 to 2-0-0, Intenor(1) 2-0-0 to 6-11-4 zone;C-C for members and forces & MWFRS for reactions shown, Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 135 lb uplift at joint 3, 99 lb uplift at joint 2 and 8 lb uplift at joint 4. This item has been electronically signed and sealed by Albani, Thomas, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on,any electronic copes. Thomas A A1b ni E;t46.303 0 h9i'ek17SA,Ir,c.LCart66 69Q4 Park&'EaatBiya X` a361Q February 23,2018 WARNING • Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE A411-7473 rev. 1"312015 BEFORE USE. Design valid for use Only with Mire", Connectors. This design is based only upon parameters shownand is for an individual building component, not a truss system. Before use. the building designer must verity the applicability of design parameters and property incorporate this design into the overall vpbuilding design, Bracing indicated is to prevent buckling of individual truss web andtor chord members Only. Additional temporary and permanent bracing' is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIfTPN Quality Criteria, DSB-t19 and SCSI Building Component 6904 Parke East Blvd. Safety information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, AJexandria, VA 22314. Tampa, FL 36610 Jab 'Truss Truss Type Qty Ply Park Sq/ Sundance-1730-A T73325066 P1730A J58 JACK 1 1 Mid -Florida Lumber, Bartow, FL. In I 8,130 s Sep 15 2017 MiTek Industries, Inc. Fri Feb 23 13:14:37 2018 Page 1 ID:3zzrE5595gHBgKdROwR6OYzkwee-kvlMvlRniTYnh)RnXG7orxfgQOC VMfgIL2PeZAziF 5W Scale = 1:19.0 3x4 = LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Lid PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.43 Vert(LL) 0,06 4-7 >999 240 MT20 244/190 TCDL 10,0 Lumber DOL 1.25 BC 0.34 Vert(CT) -0.10 4-7 >668 180 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) 0.00 2 n/a n/a BCDL 10.0 Code FBC2017(rP12014 Matrix -MP Weight: 20 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 5-8-0 oc purlins. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS, (lb/size) 3=146/Mechanical, 2=290/0-3-8, 4=73/Mechanical Max Horz 2=145(LC 12) Max Uplift 3=-108(1_C 12), 2=-86(LC 12), 4=-7(LC 12) Max Grav 3=146(LC 1), 2=290(LC 1), 4=104(LC 3) FORCES, (lb) - Max, Comp./Max. Ten. - All forces 250 (lb) or less except when shown NOTES- 1) Wind: ASCE 7-10, Vuh=140mph (3-second gust) Vasd=108mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; Cat. 11, Exp B; Encl., GCpi=0.18; MVVFRS (envelope) gable end zone and C-C Exterior(2) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 5-7-4 zone;C-C for members and forces & MWFRS for reactions shown, Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live bads. 3) " This truss has been designed for a live load of 20,Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 108 lb uplift at joint 3, 86 lb uplift at joint 2 and 7 lb uplift at joint 4. This item has been electronically signed and sealed by Albani, Thomas, PE using a Digital Signature, Printed copies of this document are not considered signed and sealed and the signature must be verified on„pny electronic coes. ThornasA A)b niRE"Io.39 A1i e lTSA,1 c Cart RB 6994 Rark13 £ 1vd.T 1; 33611f February 23,2018 WARNING - Verity design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 1111II.7473 rev. 101,1312015 BEFORE USE. Design valid for use only with MiTeks@ connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verity the applicability of design parameters and property incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only, Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabncabonq storage, delivery, erection and bracing of trusses and truss systems, see ANSlfTP11 Quality Criteria, OSS-89 and BCSI Building Component 6904 Parke East Blvd, Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Jab ss Truss Type Oty Ply Park Sql Sundance-1730-A ,__.. P1730A JACKIJ T13325067 i t Job Referenceo if n Mid -Florida Lumber, Bartow, FL, 8.130 s Sep 15 2017 MiTek Industries, Inc. Fn Feb 23 13 14 40 2018 Page 1 I D:3zzrE5595gHBgKdROwR6OYzkwee-8URUXKTg?OwMYAAMDPh WrZHO_DGfZOPB i OdIAUziF5T I -1-5.0 4-2-15 _____.._....... 1-5-0 4.2.15 2x4 = LOADING (psf) SPACING- 2-0-0 TCLL 20,0 Plate Grip DOL 1.25 TCDL 10.0 Lumber DOL 1.25 BCLL 0.0 Rep Stress Incr NO BCDL 10.0 Code FBC2017I P12014 Scale: 1 "=1 ` CS1. DEFL. in (loc) I/defl L/d PLATES GRIP TC 0,22 Vert(LL) -0.01 4-7 >999 240 MT20 244/190 BC 0.18 Vert(CT) -0.03 4-7 >999 180 WS 0= Horz(CT) 0.00 2 BIB n/a Matrix -MP Weiqht: 15 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No,2 TOP CHORD Structural wood sheathing directly applied or 4-2-15 oc purlins. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 3=101/Mechanical, 2=262/1-0-0, 4=49/Mechanical Max Harz 2=96(LC 4) Max Uplift 3=-65(LC 8), 2 138(LC 4), 4-3(1-C 8) Max Gray 3-101(LC 1), 2=262(LC 1), 4=75(LC 3) FORCES, (lb) - Max, Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10, Vult=140mph (3-second gust) Vasd=108mph, TCDL=4.2psf; BCDL=3.Opsf, h=25ft: Cat. 11, Exp B, End., GCpi=0.18, MWFRS (envelope) gable end zone, Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10,0 psf bottom chord live load nonconcurrent with any other live loads. 3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 65 Ill uplift at joint 3, 138 It, uplift at joint 2 and 3 lb uplift at joint 4. 6) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 71 lb down and 12 lb up at 1-&12, and 71 lb down and 12 lb up at 1-6-12 on top chord, and 10 lb down and 5 lb up at 1-6-12, and 10 lb down and 5 lb up at 1-6-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 7) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-3=-60, 4-5=-20 Concentrated Loads (Ib) Vert: 9=7(F=4,B=4) WARNING' Varffy design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 014479 rev, 10/63/2015 BEFORE USE. Design valid for use only with MiTeM connectors. This design is based only upon parameters shownand is for an individual building component, not a truss system. Before use. the building designer must verify the applicability of design parameters and property incorporate this design into the overall Wining design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems. see ANSUTPIi Quality Criteria, DSB49 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street- Suite 312, Alexandria, VA 22314. This item has been electronically signed and sealed by Albani, Thomas, PE using a Digital Signature. Printed Copies of this document are not considered signed and sealed and the signature must be verified on, pny (,lectroniq copies. Thames A A1ba11RE No.3 Mf ek t)SA, lrtc.L Cart&& I# 8Ad Paftt Elf 6kvd. i` 3381U February 23,2018 irm 6904 Parke East Blvd. Tampa, FL 36610 Job Truss Truss Type 70tyPiy ' Park Sq/ Sundance-1730- AT13325068P1730AKJ3A.. Mid -Florida Lumber, Bartow, FL. 8.130 s Sep 15 2017 MiTek Industries, Inc. Fn Feb 23 13:14:40 2018 Page 1 I D:3zzrE5595gHBgKdROwR6OYzkwee-8URUXKTg?OwMYAAMDPh WTZHPxDHAZOPB 1 OdIAUziF5T f--------_. 3-3-10 _...( 3-3-10 Scale-. 1 "=1' 7x6 LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (loc) Well Ltd PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0,16 Vert(LL) 0.01 4-8 >999 240 MT20 244f190 TCDL 10.0 Lumber DOL 1.25 BC 0.08 Vert(CT) -0.01 4-8 >999 180 BCLL 0.0 ' Rep Stress Incr NO WB 0.00 Horz(CT) 0.00 1 ma n/a BCDL 10.0 Code FBC2017ITP12014 Matnx-MP Weight: 13 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 3-3-10 oc punins. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 3=88/Mechanical, 4=36tMechanical, 1=122/0-1-8 Max Horz 1=49(LC 4) Max Uplift 3=-58(LC 4), 4=-4(LC 4), 1=-32(LC 4) Max Grav 3-88(LC 1), 4=52(LC 3), 1=122(LC 1) FORCES. (lb) - Max. Comp,[Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10, Vult=140mph (3-second gust) Vasd=108mph, TCDL=4.2psf, BCDL=3.Opsf, h=25ft, Cat. 11, Exp B, End., GCpi=0.18, MWFRS (envelope) gable end zone, Lumber DOL=1.60 plate grip DOL-1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) ' This truss has been designed for a live load of 20.0psf on the bottom chard in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Bearing at joint(s) 1 considers parallel to grain value using ANSI/TPI 1 angle to grain formula, Building designer should verify capacity of bearing surface. 6) Provide mechanical connection (by others) of truss to bearing plate at joint($) 1. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 58 lb uplift at joint 3, 4 lb uplift at joint 4 and 32 lb uplift at joint 1. 8) Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.500in. 9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 52 lb down and 9 lb up at 0-7-8 on top chord, and 10 lb down and 5 lb up at 0-7-8 on bottom chord. The design/selection of such connection device(s) is the This item has been responsibility of others. electronically signed and 10) in the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). sealed by Albans, Thomas, PE LOAD CASE(S) standard using a Digital Signature. 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Printed copies of this Uniform Loads (plf) document are not considered Vert: 1-3=-60, 4-6=-20 signed and sealed and the Concentrated Loads (lb) signature must be verified Vert: 8-4(F) on.,pQy Iectronic copies. Titoht6s A Alhatir PE No.3$36or h41'alttiSAl a.F Cart66 689d Park§ £ sf Blvd t`a fC_ 610 February 23,2018 WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MU-747J rev. 10/03/2015 BEFORE USE. Design valid for use only with MITekoo connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design into the overall building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing lfrktisalwaysrequiredforstabilityandtopreventcollapsewithpossiblepersonalinjuryandpropertydamage. For general guidance regarding the fabrication. storage, delivery erection and bracing of trusses and truss systems, see ANSIITPI1 quality Criteria, D$5-89 and SCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street. Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Truss TrussJobTruss Truss TypoTypo oty Ply Sq/ Sundance-1 730-Aty EJACK Pari( T13325069 P1730A KJ6 b R ference (---n4U Mid -Florida Lumber, Barlow, FL. 8A30 s Sep 15 2017 MiTek Industries, Inc. Fri Feb 23 13 14 41 2018 Page 1 ID:3zzrE5595qHBqKdROwR6OYzkviee-dh9tigUlmi2DAKlYm6C[?nqSqdT_[RuLGgNstxziF5S 1-5to 1-5-0 4-3-0 3-9-2 Scale = 1 183 4x4 = LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl Ltd PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 Tc 0.66 Vert(L) -013 6-9 >718 240 MT20 244/190 TCDL 10.0 Lumber DOL L25 BC 0.75 Vert(CT) -0.28 6-9 >341 180 BCLL 0.0 Rep Stress Incr NO WB 0.18 Horz(CT) 0.01 5 n/a File BCDL 10.0 Code FBC2017fTP12014 Matrix -MP Weight: 33 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc puffins. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 2x4 SP No.3 REACTIONS, (IbIsize) 4-183/Mechanical, 2=431/0-11-5,5=327i'Mechanical Max Horz 2=156(LC4) Max Uplift 4=1 53(LC 13), 2=-202(LC 4), 5=-125(LC 8) FORCES. ( lb) - Max, Comp./Max. Ten, - All forces 250 (lb) or less except when shown, TOP CHORD 2-3=5221215 BOT CHORD 2-6=-295/492 WEBS 3-6=-529/317 NOTES- 1) Wirjcl: ASCE 7-10, VuR=140mph (3-second gust) Vasd=108mph; TCDL=4.2psf: BCDL=3,Opsf, h=25ft: Cat. 11, Exp 8, Encl., GCpi= 0.18; M\rVFRS (envelope) gable end zone; Lumber DOL=1.60 plate grip DOL=l .60 2) This truss has been designed for a 10.0 psf bottom Chord live load nonconcurrent with any other live loads. 3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections, 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 153 lb uplift at joint 4, 202 lb uplift at joint 2 and 125 lb uplift at joint 5, 6) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 3 lb down and 12 lb up at 1- 6-12, 3 lb down and 12 lb up at 1-6-12, 5 lb down and 45 lb up at 4-4-12, 5 lb down and 45 lb up at 4-4-12, and 63 lb down and 99 lb up at 7-2-11, and 63 lb down and 99 lb up at 7-2-11 on top chord, and 4 lb up at 1-6-12, 4 lb up at 1-6-12, 8 lb down and 13 This item has been lb up at 4-4-12, 8 lb down and 13 lb up at 4-4-12, and 48 lb down and 22 lb up at 7-2-11, and 48 lb down and 22 lb up at 7-2-11 on electronically signed and bottom Chord. The design/selection of such connection device(s) is the responsibility of others. sealed by Albans, Thomas, PE 7) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (8). using a Digital Signature. LOAD CASE(S) Standard Printed copies of this 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate lncrease=l .25 document are not considered Uniform Loads (plf) signed and sealed and the Vert: 1-4=-60, 5-7=-20 signature must be verified Concentrated Loads (lb) on,, aQy,qlectronic copies. Vert, 12=-126(F=-63, 13-63) 13=7(F=4, B=4) 14=-l6(=-8, B=-8) 15=-85(F=-43, B=-43) Thomas'kAIb4hiPEN6,1P ,,8 13% =- d: February 23,2018 WARNING - Varity design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 41,111-7473 rev. 1010312015 BEFORE USE. Design valid for use only with Wrtkilt) connectors. This design is based only upon parameters shown, and is for an individual building component, not a miss system. Before use. the building designer must verity the applicability of design parameters and property incorporate this design into the overall bu filing design. Bracing indicated is to prevent buckling of Individual truss web antbor chord members only. Additional temporary and permanent bracing t always required for stability and to prevent collapse with possible personal injury and prOpery damage, For general guidance regarding the a s ' , piarew fabrication, storage, delivery, erection and bracing of misses and truss systems, see ANSIfTP11 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East BNd, Safety Information available from Truss Plate Institute, 218 N. Lee Street, suite m2, Alexandria, VA 22314. Tampa, FL W10 7 T—s Type 1301 =K17sob T13325070 Mid -Florida Lumber, Barlow, FL. 8.130 s Sep 15 2017 MiTek Industries. Inc. Fri Feb 23 13:14:42 2018 Page ID:3zzrE5595qHBqKdROwR6OYzkwee-5tYFy7\/wXOA4nUKkKCY_MbAlmx1r0UVK6PFNziF5R 1-5-0 5-2-5 9-10-13 1-5-0 5-2-5 4-8-8 6 3X8 5 3x4 = Scale = 1,22.7 LOADING (psf) SPACING- 2-0-0 CsL DEFL. in (lac) I/defl Lid PLATES GRIP TCLL 20.0 Plate Grip DOL 1,25 TC 0.82 Vert(LL) -0.30 6-9 >398 240 MT20 2441190 TCD1- 10.0 Lumber DOL 1.25 BC 0.96 Vert(CT) -0.64 6-9 >186 180 BCLL 0.0 Rep Stress Incr NO WIB 0.35 Horz(CT) 0.01 5 n1a n1a BCDL 10.0 Code FaC2017/TPI2014 Matnx-MS Weight: 40 lb FT = 20% LUMBER- BRACING. TOP CHORD 2x4 SP No, I TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD 2x4 SP No. 1 BOT CHORD Rigid ceiling directly applied or 9-6-8 oc bracing. WEBS 2x4 SP No.3 REACTIONS. (lb/size) 4=134/Mechanical, 2=529/0-5-11, 5-375/Mechanical Max Horz 2=186(LC 4) Max Uplift 4-1 12(LC 4), 2=-244(LC 4), 5=-158(LC 8) FORCES. (lb) - Max. Comp./Max, Ten. - All forces 250 (lb) or less except when shown, TOP CHORD 2-3=-704/322 BOT CHORD 2-6=-415/664 WEBS 3-6=-712/444 NOTES- 1) Wind: ASCE 7-10. Vult=140mph (3-second gust) Vasd-108mph, TCDL=4.2pst, BCDL=3.Opsf; h=25ft; Gat, II: Exp B; End., GCpi=0.18, MWFRS (envelope) gable end zone; Lumber DOL=l .60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads, 3) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate Capable of withstanding 112 Ito uplift at joint 4, 244 lb uplift at joint 2 and 158 lb uplift at joint 5. 6) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 71 lb down and 12 lb up at 1-6-12, 71 lb down and 12 lb up at 1-6-12, 34 Ito down and 45 lb up at 4-4-12, 34 lb down and 45 lb up at 4-4-12, and 61 lb down and 95 lb up at 7-2-11, and 61 lb down and 95 lb up at 7-2-11 on top chord, and 10 lb down and 5 lb up at 1-6-12, 10 lb down and This item has been 5 lb up at 1-6-12, 23 lb down and 13 lb up at 4-4-12, 23 to down and 13 lb up at 4-4-12, and 42 lb down and 22 lb up at 7-2-11, electronically signed and and 42 lb down and 22 lb up at 7-2-11 on bottom chord. The design/selection of such connection device(s) is the responsibility of sealed by Albani, Thomas, PE others. using a Digital Signature. 7) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (6). Printed copies of this LOAD CASE(S) Standard document are not considered 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 signed and sealed and the Uniform Loads (plf) signature must be verified Vert: 1-4=-60, 5-7--20 on,,ariy 0ectronic cop' ies. Concentrated Loads (lb) Vert: 12-85(F=43. B=-43) 13=7(F=4, B=4) 14--16(F-8, 8=-8) 15=-71(F=-36, B=-36) Thomas'kAIb4hiPE-N6 $-70 0 February 23,2018 WARNING. Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE M0-7473 rev. 1010312015 BEFORE USE, Design valid for use only with MiTek0connectoct, This design is based only upon parameters shown. and isfor an individual building component, not a truss system. Before use, the Wilding designer must verify the applicability of design parameters and property incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse win possible personal injury and property damage. For general guidance regarding the fabrication storage, delivery. erection and bracing of trusses and truss systems, see ANSIITPli Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314, Tampa, FL 36610 Job Truss Truss Type u Oty Ply Park Sq/ Sundance-1730-A T1332507t R1730A MG1 MONO TRUSS 1 i firer I Mid - Florida Lumber, Bartow, FL. 8.130 s Sep 15 2017 MiTek Industries, Inc. Fri Feb 23 13:14:43 2018 Page 1 I D:3zzrE5595gHBgKdROwR6OYzkwee-Z36dAL WYIJI xPevxuXED4Cvr cR6YmC5ej_synpziF5O 1- 2-11-8 2- 11-8 5- 8-0 -I 2- 8-8 Scale = 1 20.9 1. 5x4 II LOADING ( psf) SPACING- 2-0-0 CsL TCLL 20.0 Plate Grip DOL 1.25 TC 0.45 TCDL 10.0 Lumber DOL 1.25 BC 0.94 BCLL 0,0 Rep Stress Incr NO WB 0.71 BCDL 10.0 Code FBC20171TPI2014 Matrix -MP Jx y 4 6x6 DEFL. in (loc) 1/deft Lid Vert( LL) 0.04 5-7 >999 240 Vert( CT) -0.06 5-7 >999 180 Horz( CT) 0.01 4 We We LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD BOT CHORD 2x6 SP No.1 WEBS 2x4 SP No.3 *Except* BOT CHORD 3- 4: 2x4 SP No.2 REACTIONS. ( lb/size) 1=1652/0-3-8, 4=1305/Mechanical Max Horz 1=124(LC 8) Max Uplift 1=-680(LC 8), 4=-532(LC 8) FORCES. ( Ib) -Max. Comp,/Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-2219/846 BOT CHORD 1-5=-856/2000, 4-5=-856/2000 WEBS 2-5=726/1861.2-4=-2293/981 PLATES GRIP MT20 244/190 Weight: 32 lb FT = 20% Structural wood sheathing directly applied or 3-6-0 oc purlins, except end verticals. Rigid ceiling directly applied or 7-8-2 oc bracing. NOTES- 1) Wind: ASCE 7-10; Vult=140mph (3-second gust) Vasd=108mph: TCDL=4.2psf, BCDL=3.Opsf, h=25ft, CaL II; Exp B, Encl., GCpi= 0.18, MWFRS (envelope) gable end zone, Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) " This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 680 lb uplift at joint 1 and 532 lb uplift at joint 4. 6) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 1697 Ib down and 810 lb up at 1- 8-12, and 819 lb down and 263 lb up at 3-8-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 7) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-3=-60, 1-4=-20 Concentrated Loads (lb) Vert 8=-1697(B) 9=-819(6) WARNING • Verify design parameters and READ NOTES ON THfS AND INCLUDED MITEK REFERENCE PAGE Mfh7473 rev. 10/03/2015 BEFORE USE. Design valid for use only with MiTek14 connectors. This design is based only upon parameters shown, and is for an individual building component. not a truss system. Before use, the building designer must verity the applicability of design parameters and property incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web andror chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIrrPh Quality Criteria, DSE-89 and SCSI Building Component safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314, This item has been electronically signed and sealed by Albani, Thomas, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on,, any electronic Copies. Thomas A Albanf'PE1N6 393 copies. Mi tek Ski i C4rt&8 3894ParkSs i1F`•"Dzg February 23,2018 07. 6904 Parke East Blvd. Tampa, FL 36610 Symbols PLATE LOCATION AND ORIENTATION 3I " Center plate on joint unless x, ya offsets are indicated. Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss and fully embed teeth. Q `11 fir« For 4 x 2 orientation, locate plates 0- '4' from outside edge of truss. This symbol indicates the required direction of slots in connector plates. Plate location details available in MiTek 20t20 software or upon request. PLATE SIZE The first dimension is the plate width measured perpendicular4x4toslots. Second dimension is the length parallel to slots. LATERAL BRACING LOCATION Indicated by symbol shown and/or by text in the bracing section of the output. Use T or I bracing if indicated. BEARING Indicates location where bearings supports) occur. Icons vary but reaction section indicates joint number where bearings occur. Min size shown is for crushing only. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing. BCSI: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses. 6-4-8 1 dimensions shown in ft-in-sixteenths Drawings not to scale) 2 3 TOP CHORDS BOTTOM CHORDS neralF- Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI. 2. Truss bracing must be designed by an engineer. For wide truss spacing, individual lateral braces themselves may require bracing, or alternative Tor I p bracing should be considered. O 3. Never exceed the design loading shown and never tTj i stack materials on inadequately braced trusses. Q O 4. Provide copies of this truss design to the building F- designer, erection supervisor, property owner and ail other interested parties. 8 7 6 5 if 5. Cut members to bear tightly against each other. JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERSILETTERS. PRODUCT CODE APPROVALS ICC-ES Reports: ESR-1311, ESR-1352, ESR1988 ER-3907, ESR-2362, ESR-1397, ESR-3282 Trusses are designed for wind loads in the plane of the truss unless otherwise shown. 6. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI(TPI 1. 7. Design assumes trusses will be suitably protected from the environment in accord with ANSIITP€ 1. 8. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 9. Unless expressly noted, this design is not applicable for use with fire retardant, preservative treated, or green lumber. 10. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 11. Plate type, size, orientation and location dimensions indicated are minimum plating requirements. 12. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 13. Top chords must be sheathed or purlins provided at spacing indicated on design. Lumber design values are in accordance with ANSI/TPI 1 114Bottom chords require lateral bracing at 10 n. spacing, section6.3 These truss designs rely on lumber values or less, if no ceiling is installed, unless otherwise noted. established by others. 15. Connections not shown are the responsibility of others. C 2012 MlTekO All Rights Reserved MiTek Engineering Reference Sheet: MII-7473 rev. 10/03/2015 16. Do not out or after truss member or plate without prior approval of an engineer. 17. Install and load vertically unless indicated otherwise. 18. Use of green or treated lumber may pose unacceptable environmental, health or performance risks. Consuft with project engineer before use. 19. Review all portions of this design (front, back, words and pictures) before use. Reviewing pictures atone is not sufficient. 20. Design assumes manufacture in accordance with ANSI/ TPI 1 Quality Criteria. ii `r zv^ m 24' 24' 24' GARAGE NOTE: SEE ENGINEERING PROFILES FOR SPECIAL CONNECTIONS AND NAILING SCHEDULES. FLOOR SPACING 247O.C.UNLESS OTHERWISE NOTED. ALL WALLS SHOWN ARE LOAD BEARING AT 9'-4" UNLESS OTHERWISE NOTED. J L 5-MUS26 1-PLYHGR 3-HGUG26' 2-PLYHGRS. A b^ 15-MMUS46FLR.HSRS APPROVED TRUSS ANCHOR BYBUILDER 8OTTOM=wu TOP =4x2 2x4Cont. Band r-` TRUSS END DETAIL APPROVED TRUSS ANCHOR DYBUILDER PLUMB CUT OVERHANG HEEL HEIGHT =2x4 8OTTDM= 2x4 12 T0P= 2x4 S Npw- 12 TRUSS END DETAIL n^- BARTOW. FLDRIDA TRUSS LOADING CONDITIONS N/ A r 28_171'8max Y Permit # City of Sanford Building and Fire Prevention Product A.pprovl Specification Form 18-1265 Project Location Address As required by Florida Statute 553.842 and Florida Administrative Code 9N-3, please provide the information and product approval number(s) on the building components listed below if they are to be utilized on the construction project for which you are applying for a building permit. We recommend that you contact your local product supplier should you not know the product approval number for any of the applicable listed products. Be aware that windows, skylights, and exterior doors must be tested in accordance with the Florida Building Code, Section 1714.5. More information about Statewide Product Approval can be obtained at www.floridabuilding.org. The following information must be available on the jobsite for inspections: 1. This entire product approval form 2. A copy of the manufacturer's installation details and requirements for each product. Category / Subcategory Manufacturer Product Description Florida Approval # include decimal 1. Exterior Doors Swinging Therma - Tru Single Door FI-8871.5 Sliding MI Windows and Doors Series 420 Alum SGD - 2 Panel FL 15332A Sectional Clopay Building Products 94/T40-W4 FL1 5279.20 Roll p Automatic Other 2. Windows Single Hung MI Windows & Doors Series GA 185 Aluminum SH FL 17499.2 Horizontal Slider Casement Double Hung Fixed MI Windows & Doors Series GA 185 Alum Picture Fixed FL1 5349.1 Awning Pass Through Projected Mullions MI Windows & Doors 5764 Verical Alum Mullion FL 153512 Wind Breaker Dual Action Other June 2014 Category / Subcategory Manufacturer Product Description Florida Approval # including decimal) 3. Panel Walls Siding James Harding Bldg Products Hardie Panel FL1 3223.2 Soffits Aluminum Coils, Inc Coils Soffits FI-12194.1 Storefronts Curtain Walls Wall Louver Glass block Membrane Greenhouse E.P.S Composite Panels Other 4. Roofing Products Asphalt Shingles IKO Industries, LTD Asphalt Shingles Cambridge FL7006.1 Underlayments Warrior Roofing 15 and #30 Roofing Felt FL2346,1 Roofing Fasteners Nonstructural Metal Roofing Wood Shakes and Shingles Roofing tiles Roofing Insulation Waterproofing Built up roofing System Modified Bitumen Single Ply Roof Systems Roofing slate Cements/ Adhesives Coating Liquid Applied Roofing Systems Roof Tile adhesive Spray Applied Polyurethane Roofing E.P.S. Roof Panels Roof Vents Other June 2014 Category / Subcategory Manufacturer Product Description Florida Approval # include decimal) 5. Shutters Accordion Bahama Colonial Roll up Equipment Other 6. Skylights Skylights Other 7. Structural Components Wood Connectors Anchors Truss Plates Engineered Lumber Railing Coolers/Freezers Concrete Admixtures Precast Lintels Insulation Forms Plastics Deck / Roof Wall Prefab Sheds Other 8. New Exterior Envelope Products Applicant's Signature - Applicant's Name fv\ g&-L , Please Print) June 2014 Florida Building Code Online Page I of 8CIS Home , Log In User Registration Hot Topics Submit Surcharge Stats & Facts 1 Product ApprovaldbF, t, - I r 00—o'., USER: Public User LMauqAWMALL4&nu >Product or Anpiir Hon Search > p Ica I n is > Application Detail FL # FL8871-R8 Application Type Revision Code Version 2017 Application Status Approved Comments Archived 8 oar ti N, N' m Publications FBC Staff BCIS Site Map Links Search Product Manufacturer Therma-Tru Corporation Address/Phone/Email 118 Industrial Drive Edgerton, OH 43517 419) 298-1740 rickw@rwbidgconsultants.com Authorized Signature Vivian Wright rickw@rwbldgconsultants.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Exterior Doors Subcategory Swinging Exterior Door Assemblies Compliance Method Evaluation Report from a Florida Registered. Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed Lyndon F. Schmidt, P.E. the Evaluation Report Florida License PE-43409 Quality Assurance Entity National Accreditation and Management Institute Quality Assurance Contract Expiration Date 12/31/2021 Validated By Ryan J. King, P.E. Validation Checklist - Harcicopy Received Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By EM of lade-pendgnStpdf 514DAAr-d ASTM D1929 ASTM D2843 ASTM D635 ASTM E1300 ASTM E84 ASTM G26 TAS 201, 202, 203 Florida Licensed Professional Engineer or Architect yv-m 1996 1999 2003 1998 2000 1995 1994 http://,AAww.tloridabuilding.org/prlpr_app_dt].aspx?param=wGEVXQNA,,tDqty3 . Wak2nHrp... 2/101/2018 Florida Building Code Online Page 2 of 3) 4:! Sections from the Code Product Approval Method Method I Option D Date Submitted 10/17/2017 Date Validated 10/17/2017 Date Pending FBC Approval 10/19/2017 Date Approved 12/12/2017 Summary of Products FL # Model, Number or Name 8871.1 a. "ClassicCraft Rustic" Series Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant; Yes Design Pressure: N/A Other: See INST 8871,1 for Design Pressure Ratings by specific Model and for any other additional use limitations and installation instructions. Description 3'6 x 8'0 "Impact" Opaque Fiberglass Radius Top Single Door (X) - Inswing or Outswing Installation Instructions Fj InLt 8871 I_pdf Verified By: Lyndon F. Schmidt, P.E. 43409 Created by Independent Third Party: Yes Evaluation Reports f,887l _R AE,.(+h)_T- p Created by Independent Third Party: Yes 8871.2 b. "ClassicCraft" or "ClassicCraft Rustic" Series 3'6 x 8'0 "Impact" Opaque Fiberglass Single Door (X) Inswing or Outswing Limits of Use Installation Instructions Approved for use in HVHZ: Yes F Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 8871.2 for Design Pressure Ratings by f3L-azi _F8 specific Model and for any other additional use limitations Created by Independent Third Party: Yes and installation instructions, 8871.3 c, "ClassicCraft" or "ClassicCraft 3'6 x 8'0 "Impact" Opaque Fiberglass Single Door with Rustic" Series Sidelite (OX or XO) - Inswing or Outswing Limits of Use Installation Instructions Approved for use in HVHZ: Yes fLaL7j__U b) lntE 71 _L jf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 8871.3 for Design Pressure Ratings by EL 871 _a8_AE b Eval 8871 idf specific Model and for any other additional use limitations Created by Independent Third Party: Yes and installation instructions. (For FiberClassic and SmoothStar sidelites, this product approval requires the use of "I" part numbers for these sidelites, which have been stained or painted within six months of installation.) 8871A d. "ClassicCraft" or "ClassicCraft Rustic" Series 3'6 x 8'0 "Impact" Opaque Fiberglass Single Door with Sidelites (OXO) - Inswing or Outswing Limits of Use Installation Instructions Approved for use in HVHZ: Yes FoaZ I _R Tab jns UL _Lj?L_1f Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 8871.4 for Design Pressure Ratings by E1_8871 R AE 1, vAl 8 71 4 df specific Model and for any -other additional use limitations Created by Independent Third Party: Yes and installation instructions. (For, FiberClassic and SmoothStar sidelites, this product approval requires the use of ")' part numbers for these sidelites, which have been stained or painted within six months of installation.) 8871.5 Z "FiberClassic" or "SmoothStar" 3'0 x 8'0 "Impact" Opaque Fiberglass Single Door (X) Series Inswing or Outswing Limits of Use Installation Instructions Approved for use in HVHZ: Yes fLaaD/ P3_11 1b)2n5 71 _p jfL Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant* Yes Created by Independent Third Party; Yes Design Pressure: N/A Evaluation Reports Other: See INST 8871.5 for Design Pressure Ratings by F,8r, :L_PS AlaiEval 8871 5 df specific Model and for any other additional use limitations Created by Independent Third Party: Yes and installation instructions. hap://www.tloridabuildin.orglr/ r app dtlaspx?pararn=wGEVXQw-tDqty'1j Wak2nHM.. 2/10/.L'2018PIP — 3 Florida Building Code OnlineZ.- Page 3 of 3Z- 8871.6 f, "FiberClassic" or "Smoothstar" 3'0 x 8'0 "Impact" Opaque Fiberglass Single Door with Series Sidelite (OX or XO) - Inswing or Outswing Limits of Use Installation Instructions Approved for use in HVHZ: Yes LL-8 b 71 R —F] I t b I I 1-1571 Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 8871,6 for Design Pressure Ratings by EL—M2—IR8 specific Model and for any other additional use limitations Created by Independent Third Party: Yes and installation instructions. (For FiberClassic and SmoothStar sidelites, this product approval requires the use of ")' part numbers for these sidelites, which have been stained or painted within six months of installation.) 8871. 7 9. "FiberClassic" or "SmoothStar" 3'0 x 8'0 "Impact" Opaque Fiberglass Single Door with Series Sidelites (OXO) - Inswing or Outswing Limits of Use Installation Instructions Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Verified By: Lyndon F, Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 8871.7 for Design Pressure Ratings by EL 871R8 AEt F vaLaaZ,1_7 pdf specific Model and for any other additional use limitations Created by Independent Third Party: Yes and installation instructions, (For Fiber -Classic and SmoothStar sidelites, this product approval requires the use of " Y' part numbers for these sidelites, which have been stained or painted within six months of installation.) 8871. 8 lh, "FiberClassic", "SmoothStar", 60 x 8'0 "Impact" Opaque Fiberglass Double Door (XX) ClassicCraft"' or "ClassicCraft Inswing or Outswing Rustic" Series Limits of Use Installation Instructions Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 8871.8 for Design Pressure Ratings by specific Model and for any other additional use limitations Created by Independent Third Party: Yes and installation instructions. 8871. 9 i. "FiberClassic", "SmoothStar", 6'0 x 8'0 "Impact" Opaque Fiberglass Double Door with ClassicCraft" or "ClassicCraft Sidelites (OXXO) - Inswing or Outswing Rustic" Series Limits of Use Installation Instructions Approved for use in HVHZ: Yes IL_LL) In5,LLaZLQj1gf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 8871.9 for Design Pressure Ratings by fLU71 Pa A- , Evk1—U-7—L2J2.0—f specific Model and for any other additional use limitations Created by Independent Third Party: Yes and installation instructions. (For FiberClassic and SmoothStar sidelites, this product approval requires the use of " Y' part numbers for these sidelites, which have been stained or painted within six months of installation.) F.- ocTl FN---11 QD- M= :: Z§QL.Pi at— Tl h F'2 9 Ltan-t-91Q-4L7—IU-4 The State of Florida is an AA/EEO employer. Flgr,,OL :: :: A i ill 4 m n :: Rgfund Statement Joinder Florida law, email addresses are public records. If you do not want yoore-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail, It you have any questions, please contact 850.487.1395. -Pursuant to Seaton 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The annals provided may be used for official communication with the licensee. However email addresses are public record, If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F,S., please click tljqrg_. Product Approval Accepts: M U im E- M C' edCard Safe http://' NNAvw. floridabuilding.org/ r/ r app dtl.a,spx?paraii-i=wGEVXQNNrtDqty-')IjWak2nHrp... 2/10/20 18 Z=,p1P SMOOTH STAR & FIBER CLASSIC FIBERGLASS SINGLE DOOR INSWING / OUTSWING qENERAL MOTES " IMPACT" 1. This product has been evaluated and is in compliance with the 6th Edition (2017) Florida Building Code ]FBC) structural requirements including the "High Velocity Hurricane Zone" (HVHZ). 2, Product anchors shall be as fisted and spaced as shown on details. Anchor embedment to bole material shall be beyond wall dressing or stucco. 3. When used in the "HVHZ" this product complies with Section 1626 of the Florida Building Code and does not require an impact resistant covering. 4- When used in areas outside of the "EIVI-1Z'requiring wind bome debris protection, this product complies with FBC Sections 1609.1.2 & R301.2.1.2 and does not require an impact resistant covering. This product meets missile level'D" and includes Wind Zone 4 as defined in ASTM E 1996 and FBC Sections 1609.1.2.2 & R301.2.1.2.1, 5. For 2x stud framing construction, anchoring of these units shall be the some as that shown for 2x buck masonry construction, 6. Site conditions that deviate from the details of this drowing require further engineering analysis by a licensed engineer or registered architect. 7. Oulswing configurations using coastal sill item 44 under active doors meet water infiltration requirements for "HVHZ". 8. Inswing configurations and oulswing configurations using sill item 45 under the door do not meet the water infiltration requirements for the "H07'and shall be installed only in non -habitable areas or a, habitable locations protected by an overhang or canopy such that the angle between the edge of canopy of overhang to sill is less than 45 degrees. TABLE Of CONTENTS SHEET I DESCRIPTION FHEET# I Typical elevations, design pressures generaInalf1s anchoring - 1 X buck masonry construction _-,` ______ 22--- 3 T6o,6n-eldefd)s (Fiber classic) 4 finn zanial cross sections 5 sections Buck and fforre - 2X buck masonry construction fram of m6tw C o mp n, 37.75" MAX. FRAME WIDTH 3&OT MAX. PANEL WIDTH 0 O iv E z Zj Ep 0 OVERALL DESIGN PRESSURE (PSI) DOOR TYPE SWING FRAME POS11FIVE71NEGATIVEDIMENSION INSWING 37,75" x 98,00" 80.0 80.0- SMOOTH OUTSINING 37.75" x 96.59' 80.0 80.0 STAR INSWING 37.75" x 98.00" 80.0 80.0 FIBER OUTSWING 37.75" X96,50-F+80.0 1 - 80. 0 CLASSIC See Sheet 8 for design pressure Witations. t; Si rn 0 z 0z Z 6 0) Z 0 zw Gj ay r4 FL- 8871.5 SHUT _ 1 or 401 41 43 j 4b 47 j EXTERIOR 47 _ a. Av z' 0 i o m a n pip z 17J1 11%1 INTERIOR a Z U246C 42 $ so Qcw 2 F £ uy c oa HORIZONTAL CROSS SECTION a m 2 — 47 ; oZ O .11 J4 O4.07-1 O KW- TYP, e 1 I -T wco w ao T3 CORNERS ,-"',m ` o OF PANEL t EXTERIOR INTERIOR C, a a 42 TOP RAIL 43 LOCK SALE Y SDETAILA -A m DOOR PANEL " g40Smcwihstar { N b N V 0 000000' - d2 m i 00000GO I o000000 — 47 mcu~iN a4 - <,pQQQGQQ O r1440QG 403 -.cw20z0000o00 !_ w0000Qoa 153" 0000000 o o awn 000000000000000 +}j 00000000 0000'J O_> O/ 0 0 0 0 a o o '119x9 HlNGf STILE 43 BOTTOM RAIL o G 0 0 0 Q 0 v 2 CAIVERTICALCROSSSECTION : 05/22/080cG0eo0oAREAMAX. 0000000 28.86%OPEN l 0000000 " 0c000000 43 2 N.T.S. oQOQ000 Dn,RY, DWS m' ooa00000 cm, BY., LFS 3 DETAIL A•A DRAWNG W.: ¢ Panel reinforcement FE-8871.5 0 NOTE: WOOD DOOR COMPONENTS: PINE (SG >= OA2) smFxT 2 0 8 bd 61 bl 63 a4.•`• '• bb d7 EXTERIOR 67 = g ' o V: tirn 11\` Z am CJ/ '// I1t1111 r UN•:z INTERIOR bb b2 \\ o p v z mbb \ N i u y poa 1 HORIZONTAL CROSS SECTION m 4 3 o i Tzb7tiO J 0 TYP.4 13 CORNERSm OF PANEL a ' r' EXTERIOR INTERIOR u a a 62 TOP RAf1 63 LOCK Si11E x x ('> 3 r Ll DETAIL A -A - b 60 POOR PANEL fiber classic o N m O ryy mm ZZ 00000000 d2 W m lxi O 000000000000000 a TE O D 1_ O bd o000000 _ o coo 00 00 00 00 00 00 00000000 0 0 0 0 0 0 1.53" 0000000o bb - `T. bb a. 0aa 0000000 00000000 000no00 Q 00000000 00000000000k21A-,O o 0000 0 1qNiNGE STiI E 65 10TTOM RAIL N_ 00000000 O 00 0 0 0 0 0 28.86%OPEN 2 VERTICAL CROSS SECTION anrE: 05/22/O8 000000o AREA MAX. $ scuF: N.T.S. _ 1 09'J"-00 t 00000000 9 _ OOOOO DO - - BY: i)t• 1/S 0000ovoo ._ cN c. sr: I_ FS DETAIL A -A DRkWNG NO.' Panel reinforcement FL-887I.5 NOTE: WOOD DOOR COMPONENTS: PINE ( SG >= 0.42) Sven 3 8 L j VC Q° Ti °y o'; 0 yam; " `0 z ow 6 Il!!1 111 00 N z o7,3 oa 19 INTERIOR a" m a a m a O " 4o y o a 0 4 fl 3 4 0 z 18 EXTERIOR AO 14 O Q ate' fl o b0 A CKrn I: } Sa w otn tiwisot 1- 1J4"MIN. a 0:o 08 5 5 $ 3 HORIZONTAL CROSS SECTION 1 4 S# vn wii X sub -buck L Y )n 0. 15' 0.15" i 1) " C' SINK C'SINK ° nE.) 1 it r a y 8 9 9 8 10 INTERIOR INTERIORo hw- 1 b j C O O O N l G Q " V hN •- 12 12 40 EXTERIOR EXTERIOR 40 14 1b w£: 05 22 D8 11/ 4"MIN.-- 60 EAAB. jnP.) 1- 1/4-MIN, cw. BY. ITS 1 HORIZONTAL CROSS SECTION 2 HORIZONTAL CROSS SECTION -EMB. (nE.) oanmNc No: 4 Ouisz shown - inswing 4 Outswing shown - inswing also app oved also approved F1 — 887 t .5 SWEI 4 0 8 EXTERIOR- INTERIOR rl ), VER71CAL CROSS SECTION k own - inswingitson9osvhed EXTERIOR INTERIOR r4-'VERTICAL CROSS SECTION configurationKTT's eeHgne_2nefal —notes— sheet I fof"HVHT' Water infiltration requirements 4 4 l—L—A a I . , EXTERIOR —I/— INTERIOR 2 VERTICAL CROSS SECTION 11$ Shown w/lX sub -buck EXTERIOR INTERIOR r5')EVERTICAL CROSS SECTION nseegeneralHoles, e, for'HVHZ"walef infiltration requirements INTERIOR A, z I; zt .,6 EXTERIS, pf 1z 6; 6 it, 0, z 0 0 A 6 4:0 M 60 Z r3'), VERTICAL CROSS SECTION Wswing configuration see general notes, sheet I for'IIVHZ" —ter infiltration requirements INTERIOR EXTERIOR r6VERTICAL CROSS SECTION Outswin' conf ur on see general notes, sheet 1 for, lIVHZ" water infiltration requirements L K 019 N. T. S. BY: Dws ry — LFS F- L-8871.5 Q i z 41 m 7pf D < jj 7•. m V N ': p a Z Q TYP. HEAD & N f E MASONRY _ JAMBS MASONRYAMBHEAD N a r a OPENING OPENING ro maa r a\\ VO A Jd ' J zQFRAMEi O f U r Ira 2X BUCK -, I 2X BUCK O Z^ moo oz z ca N o W ca4 Q xxJam BUCK ANCHORING HINGE JAMB FRAME ANCHORING STRIKE JAMB Masoray 2X buck construction 0 0 N w a+ N nCiL O O V7 CONCRETE ANCHOR NOTES: o 1. Concrete anchor locations at the comers may be adjusted to maintain the min. edge distance to mortar joints. MAX. 1 5 2. Concrete anchor locations noted as ON CENTER" must be adjusted to a m a o. maintain the min. edge distance to mortorjoints, additional concrete anchors may be required to ensure the 'MAX. ON CENTFR•' dimension ore not exceeded. 12 3. Concrete anchor fable: l2' 14 ITW 12 22 WE:05 0$ T 7J4„ 4„ TAPCON jai n a c TYP. HEAD rtitil pt o n . JAMBS t z° U o n h$ V Z p 7 V MASONRY N s o o OPENING ur n v y m a `a V, m cpo C= 3: o 3 a to V NO in GFRAME - j- 15 o OU Za 0 1 X BUCK he LATCH d DEADBOLTDfiAH Vtrl 1n V o N a 0 er N vflm V po HINGE JAMB STRIKE JAMB rp o cN o o CONCRETE ANCHOR NOTES: TRAMEANCHORING Masanry 3X buck o '' a a1. Concrete anchor locations of the comers may be adjusted to maintain the min. constrvci an 12 o edge distance to morior joints. 2. Concrete locations noted as "MAX. ON CENTER" must be adjusted to 12 a anchor maintain the min. edge distance to mortar joints, additional concrete anchors L _.- may be required to ensure the "MAX. ON CENTER"dimension are not exceeded. 3. Concrete anchor table: 12'" ANCHOR ANCHOR MIN. -: MIN. CLEARANCE MIN. 12 z a n<v- ZL u zwTf: 5 22 08ITW scarf: N. T. S. ° HINGE DETAIL eITAI : L7WYS cr+x, By'.LFS 3 WOOD SCREW INSTALLATION NOTES: www.: amtrm 1. Maintain a m»um 5/8" edge distance, r" end distance, & 7"o.c. spacing ofirm FL-8871.5 aawoodscrewstopreventthesplittingofwood. CLEARANCE TYPE-- SlZE. - EMBEDMENT TO MASONRY TOADJACENi EDGE ANCHOR 7APCON 3Jl b" 1.1J4" 3" 7APCON® BILL OF MATERIALS ITEM DESCRIPTION MATERIAL IX BUCK SG >=_2,55 WOOD B 2X BUCK SG - 0.55 WOOD WOODCMAX. 114- SHIM SPACE D 1/4" X 2-3/4'PFH ELCO OR ITW CONCRETE -SCREW STEEL E MASONRY - 3,ODO PSI MIN. CONCRETE CONFORMING TO ACI CONCRETE 301 OR HOLLOW BLOCK CONFORMING TO ASTM C90 CONCRETE SCREW STEEL-- J I/4"X3-3/N'PFH ITW CONCRETES_ STEEL L 41OX2-1/2"PFH WOOD SCREW 1.15'MIN. EMBEDMENT) STEEL I INSWING ADJUSTABLE THRESHOLD fIS300AJ) ALUM./WOOD 2 SWfNG'fRI ETHbLD (IS300HP5) 3- INSWING SELF ADJUST THERMAL BREAK THRESHOLD (ISP30M) 4 OUTSWING COASTAL THRESHOLD ALUM./COMP. ALUM.IWOOD 5 OUTSWING STANDARD THRESHOLD ALUM./WOOD_ 6 INSWING THRESHOLD ALUM./COMP. 7 DOOR BOTTOM VINYL 8 JAMB (PINE) SG >= 0,42 WOOD 9 JAMB (OAK) SG >= 0.42 WOOD 10 WEATHERSTRIP FOAM I I HINGE STEEL IT 10 X 3X PFH SCREW STEEL 13 9 X 3' PFH WOODffRbW— STEEL 14 LATCH STRIKE PLATE Sfetc 15- SECURITY STRIKE PLATE STEEL 16 P8 X 2-1/7'PFH STEEL 17 J-8—X 3/4" PFHSCREW STEEL 18 KWiKSET SERIES PASSAGE LOCK STEEL 19 1 KWIKSETK— RIES DEADBOLTbb0j STEEL 40 SMOOTH SfA-R660R - SEE DOOR PANEL DETAIL SHEET FOR DETAILS 41 DO —OR SKIN --0-.0-7T'--THK, —(SMOOTH STAR) Fy-= 6,000 PSI MIN. FIBERGLASS 42 TOP RAIL jSMOOTW STAR) --- COMP. 43 LOCK STILE (SMOOTH STAR) WOODAVL 44 HINGE —STILE (SMOOTH STAR)WOOD 45 BOTTOMRAILSTAR) COMP, PANEL REINFORCEMENT 0.023" TWK. (SMOOTH STAR]!.-— STEEL 47 FOAM CORE POLYURETHANE 50 FIBER -- CLASSIC -DOOR- --SEE DOOR —PANEL DETAIL SHEET FORDETAILS 61 DOOR SKIN 0. 1 3EIK. tF 6,000 PSI MIN. FIBERGLASS 62 TOP RAIL ( FIBER CLASSIC) 63 LOCK STILE ( FIBER CLASSIC) W0ODjLVL 64 HINGE STILE ( FIBER CLASSIC) LN WOOD 65BOTTOM RAIL ( FIBER CLASSIC) COMP. PANELREINFORCEMENT-002T—TH` K-jFIBER CLASSIC) STEEL 67 FOAM CORE POLYURETHANE coo 4.56" HEAD SIDE 5,7T THRESHOLD Inswng adpistaNe MTHREI HOLD 3 . F—,, 6 sel6adpsi o S-TRESHOLD OiAw* V standard THRESHOLD in . odjustobi-- THRESHOLD crowing coastal 5. 83" THRESHOLD ns' Ang 1111HOLII MAX. DESIGN PRESSURE 5- 0 PSF N.T.S. gy, Dws WL Fs- FL-8871. 5 T ff- or Florida Building Code Online Page 1, of 6 ETT 8CIS Home Log In User Registration Hot TOP.C$ Submit Surcharge j Stats & Facts Publications FBC Staff 5CIS Site Map Links Search lf,Product ApprovalUSER: Public User IL14k, LMd_, A Ir vi M n ) > Product or ADOJicatior Search > mop r Gst > Application Detail N. FL # FL15279-R5 Application Type Revision Code Version 2017 Application Status Approved Comments reapply 11/28/17 Archived Product Manufacturer Clopay Building Products Company Address/Phone/Email 8585 Duke Blvd. Mason, OH 45040 513) 770-6062 mwesterfield@clopay-com Authorized Signature Scott Hamilton shamilton@ciopay.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Exterior Doors Subcategory Sectional Exterior Door Assemblies Compliance Method Certification Mark or Listing Certification Agency Intertek Testing Services NA, Inc. Validated By Gary Pfuehler Validation Checklist - Hardcopy Received Referenced Standard and Year (of Standard) standard YgAlr ANSI/DASMA 108 2005 ANSI/DASMA 115 2005 ASTM E1886 2002 ASTM E1996 2002 ASTM E330 2002 Equivalence of Product Standards Certified By Florida Licensed Professional Engineer or Architect EL1527a RSEguiv 20170809 - FB. - DASMA 1115 uiv. Product Approval Method Method I Option A Date Submitted 08/!0/2017 Date Validated 11/29/20117 https://'Nk N7w.floridabuilding.or,-,!'pr.,'p r_ap p dtl.aspx?paran-i=wGEVXQw-tDqv'vVVKJZIQ... 2/11//2018 Florida Building Code Online Page 2 of 6 Date Pending FBC Approval Date Approved Summary of Products Go to Page = 'a 12/05/2017 4 0 Pagei/ad 0 FL # Model, Number or Name Description 15279,1 001 W3-09 DSIE-IA171: 2050, 1-3/8" Double -skin Insulated EPS (exterior skin 27 ga. min,; 2051, 2053, 4050, 4051, 4053, 62, interior skin 29 ga. min.) Single -Car (up to 9'0" wide) 64, 65, 62G, 62LG, 64G, SDP38, WINDCODETD W3 Garage Door SFL38, SRP38, 134, 135, 136, 6130, 6131, 6133 Limits of Use Certification Agency Certificate Approved for use in HVHZ: No Z-O-Q-f Approved for use outside HVHZ: Yes Impact Resistant: N/A F.LU279_._Eq QL, k_pdf Design Pressure: +20 PSF/-20 PSF Quality Assurance Contract Expiration Date Other: The OPTIONAL glazing available for this product 05/21/2028 meets the wind load requirements of the building code but Installation Instructions DOES NOT meet the impact resistant requirement for FI-15279 R n -_P V windborne debris regions. The product without glazing DOES Verified By: Intertek Testing Services NA, Inc. comply with the impact resistant requirement for windborne Created by Independent Third Party: debris regions (ref 1609.1.4 FBC). Evaluation Reports Created by Independent Third Party: 15279.2 002 W3-09 DSTE-IA471: GDISP, Gallery/Artistry/Expressions: 1-3/8" Double -skin Insulated GRISP, GDILP, GR1LP, ARISP, EPS (exterior skin 27 ga. min.; interior skin 27 ga. min.) ARILP, EDISP, EDILP, 4132, 2132, Single -Car (up to 9'0" wide) WINDCODES W3 Garage Door 6132, SFC38, MFC38 Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL1S279 R5 C CAC LQrter with r QLpf n r t n dr f Approved for use outside HVHZ: Yes of inspeCti n.pdf Impact Resistant: N/A no f Design Pressure: +20 PSF/-21 PSF Quality Assurance Contract Expiration Date Other: The OPTIONAL glazing available for this product 05/21/2028 meets the wind load requirements of the building code but Installation Instructions DOES NOT meet the impact resistant requirement for y.Qf, windborne debris regions. The product without glazing DOES Verified By: Intertek Testing Services NA, Inc. comply with the impact resistant requirement for windborne Created by Independent Third Party: debris regions (ref 1609.1.4 FBC). Evaluation Reports Created by Independent Third Party: 152793 003 W3-09 DSTU-IA171: 9130, Double -skin Insulated PUR (exterior skin 27 ga, min.; 9!31, 9133, HDP13, HDPF13, interior skin 27 ga. min.) Single -Car (up to 9'0" wide) HDPL13, 7130, 7131, 7133, 8130, WINDCODE& W3 Garage Door 8131, 8133 Limits of Use Certification Agency Certificate Approved for use in HVHZ: Na PLO-9-f Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +20 PSF/-20 PSF Quality Assurance Contract Expiration Date other: The OPTIONAL glazing available for this product 05/21/2028 meets the wind load requirements of the building code but Installation Instructions DOES NOT meet the impact resistant requirement for Py__=f windborne debris regions. The product without glazing DOES Verified By: Intertek Testing Services NA, Inc. comply with the impact resistant requirement for windborne Created by Independent Third Party: debris regions (ref 1609.1.4 FBC). Evaluation Reports Created by Independent Third Party: i 15279,4 004 W3-16 DSIE-IA171: 2050, 1-3/8" Double -skin Insulated EPS (exterior skin 27 ga. min.; 2051, 2053, 4050, 4051, 4053, 62, interior skin 29 ga. min.) Double -Car (9'2" to 16'0" wide) 64, 65, 62G, 62LG, 64G, SDP38, WINDCODEe W3 Garage Door SFL38, SRP38, 134, 135, 136, 6130, 6131, 6133 Limits of Use Certification Agency Certificate Approved for use in HVHZ: No PLIQ -0f Approved for use outside HVHZ,. Yes pLn pe"ndf Impact Resistant; N/A F; J5 7j_R5__ !I! __pcLf Design Pressure: +20 PSF/-21 PSF Quality Assurance Contract Expiration Date Other: The OPTIONAL glazing available for this product 05/21/2028 meets the wind load requirements of the building code but Installation Instructions DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES Verified By: Intertek Testing Services NA, Inc. comply with the impact resistant requirement for windborne debris regions (ref 1609.1.4 FBC). Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 15279.5 https.,,';,",VN-,Y,v,w.floridabuilding.org/pri'Pr-a-pT)-dtl,aspx?param=wGEVXQNk-tDqv3 yVVKJZ 1 Q... 2/11/2018 Florida Building Code Online Page ') of 6Z: 005 W3-16 DSIE-IA471: GDISP, Gal lery/Artistry/Expressions: 1-3/8" Double -skin Insulated GRISP, GD1LP, GP_1LP, ARISP, EPS (exterior skin 27 ga. min.; interior skin 27 ga. min.) AP,ILP, EDISP, EDILP, 4132, 2132, Double -Car (9'2" up to 16'0" wide) WINDCODES W3 Garage 6132, SFC38, MFC38 I Door Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure, +20 PSF/-21 PSF Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1,4 FBC). 15279.6 006 W3-16 DSIU-1A,171: 9130, 9131, 9133, HDP13, HDPF13, HDPL13, 7130, 7131, 7133, 6130, 18131, 8133 Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +20 PSF/-21 PSF Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.4 FBC). Certification Agency Certificate p I -' "Z - I . _1.Pr wi--- - 2LMM9 r n.odf jrl_j 7q_L5 C CAC W3 Li,in Intertek.df Quality Assurance Contract Expiration Date 05/21/2028 Installation Instructions EL15229_a5_jL104028-P_tv0Uf Verified By: Intertek Testing Services NA, Inc. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: Double -skin Insulated PUR (exterior skin 27 ga. min.; interior skin 27 ga, min.) Double -Car (9'2" to 16'0" wide) WINDCODE& W3 Garage Door Certification Agency Certificate fin c is n cJf Quality Assurance Contract Expiration Date 05/21/2028 Installation Instructions EL11271jP5 Ij_j04168-RcvQ1_pdf Verified By: Intertek Testing Services NA, Inc. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 15279.7 007 W3-16 PAN-21`153: 73, 1500, Steel Pan (min. 25 ga.) Double -Car (9'2" to 16'0" wide) 75, 190, 84A, 94, 42, 48, 55, 425, WINDCODE& W3 Garage Door 48B, 55S, 4RST, 6RST, 4RSF, 6RSF Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant, N/A Design Pressure: +20 PSF/-21 PSF Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.4 FBC). 15279.8 008 W4-09 DSIE-1F171: 4300, 4301, 4310, 4400, 4401, HDG, HDGL, HDGF, 66, 56G, 67, 67G, 68, SP200, SF200, SE200, 6200, 6201,6203 Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +28 PSF/-29 PSF Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609,1A FBC). Certification Agency Certificate of Contrac_* and oofpL_ Qf1 Quality Assurance Contract Expiration Date 05/21/2028 Installation Instructions FLir27q P 2d' Verified By: Intertek Testing Services NA, Inc. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 2" Double -skin Insulated EPS (exterior skin 27 ga. min.; interior skin 27 ga, min.) Single -Car (up to 9'0" wide) WINDCODE(& W4 Garage Door Certification Agency Certificate f Quality Assurance Contract Expiration Date 05/21/2028 Installation Instructions EL15279_R5 11 1016 _2-5-F evIl_p f Verified By: Intertek Testing Services NA, Inc. Created by Independent Third Party: Evaluation Reports Created by independent Third Party: 15279.9 009 W4-09 DSIE-IF471; GD2SP, Gal lery/Artistry/Expressions: 2" Double -skin Insulated EPS GR2SP, GD2LP, GR2LP, AR2SP, (exterior skin 27 ga. min.; interior skin 27 ga. min.) Single- AR2LP, ED2SP, ED2LP, 4302, Car (up to 9'0" wide) WINDCODES W4 Garage Door 1 HDGC, 6202, SFC68, mFC68 Limits of Use Certification Agency Certificate Approved for use in HVHZ: No EL1527 R5_C CAC Qf Approved for use outside HVHZ: Yes Impact Resistant: No pdf Design Pressure: +28 PSF/-29 PSF Quality Assurance Contract Expiration Date Other: The standard glazing available for this product 05/21/2028 meets the wind load requirements of the building code but Installation Instructions f ittps:///,A A,xA,,floridabuilding.orc,,'pr%pr app dtl.aspx?param=wGEVXQwtDqv3vVVKJZIQ... 2/11/2018 Florida Building Code Online Page 4 of 6 DOES NOT meet the impact resistant requirement for Verified By: Intertek Testing Services NA, Inc. windborne debris regions. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 15279.10 010 W4-09 DSIU-11`171: 9200, Double -skin Insulated PUR (exterior skin 27 ga. min.; 9201, 9203, HDP20, HDPF20, interior skin 27 ga. min,) Single -Car (up to 9'0" wide) HDPL20, 7200, 7201, 7203, 6200, WINDCODE(F) W4 Garage Door 820,8203 Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +28 PSF/-29 PSF Other, The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.4 FBC). 15279.11 011 W4_09 DSIUO-IK479: CanyonIRidge/Brookstone Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +28 PSF/-29 PSF Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.4 FBC). Certification Agency Certificate F! L5 ?_7 R5 C CAC 14Ctgr with prof of of in ection;tdf Quality Assurance Contract Expiration Date 05/21/2028 Installation Instructions Verified By: Intertek Testing Services NA, Inc. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: Double Skin Insulated PUR (exterior skin 27 ga. min.; interior skin 27ga. min.) with Overlay Single -Car (up to 9'0" wide) WINDCOD&& W4 Garage Door Certification Agency Certificate FL1 5272 RAr with , n f -f r n -,f 2Lin_-_aUL qn_pdf FL15279 R5 (- CAC W4 Lis Ljn_9_Insert tk_P_df Quality Assurance Contract Expiration Date 05/21/ 2028 Installation Instructions Verified By: Intertek Testing Services NA, Inc. Created by Independent Third Party; Evaluation Reports Created by Independent Third Party: 15279,12 012 W4-09 PAN-21`151: 73, 1500, Steel Pan (min, 25 ga.) Single -Car (up to 9'0" wide) 75, 190, 84A, 94, 76, 42, 48, 55, WINDCODEe W4 Garage Door 428, 48B, 55S, 4PST, 6RST, 4PSF, 6RSF, 2RST, GD5S, GD5SV, GP,5S, GP5SV, ARSS, AR5SV, ED5S, EDSSV Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: + 25 PSF/-32 PSF Other: The standard glazing available For this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. 15279.13 013 W4-09 PAN-2F441: G4S, GS4, G4L, GL4, GD4S, GD4L, GR4S, GR4L, G4SV, GS4V, G4LV, GL4V, GD4SV, GD4LV, GR4SV, GR4LV, E4S, E4L, ED4S, ED4L, E4SV, E4LV, ED4SV, ED4LV, S54, SL4, AR4S, AR41L, SS4V, SL4V, AR4SV, AR4LV Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: + 25 PSF/-32 PSF Other: The standard glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. 15279.14 014 W4-09 SPO-2F449: Grand Harbor, Stone Manor Certification Agency Certificate fU 279 R5 C CAC Letter with rnnf of mritrarr and roof P t- i I-1 sP".ctLqn_Of FL'6, 79 RS C AW4 i in Intp[jek.pdf Quality Assurance Contract Expiration Date 05/21/2028 Installation Instructions f Verified By: Intertek Testing Services NA, Inc. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: Gal lery/Artistry/ Expressions: Steel Pan (min. 24 ga.) Single - Car (up to 9'0" wide) WINDCODE(& W4 Garage Door Certification Agency Certificate e r w ih proof of contract ang pLQ, f Q of mE, tc' _'0L_P_df TLL5ZZ2_'.E Quality Assurance Contract Expiration Date 05/21/2028 Installation Instructions ELIL) 79 P' 348(_Peyk 2_f Verified By: Intertek Testing Services NA, Inc. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: Steel Pan (min. 24 ga.) with Overlay Single -Car (up 9'0"wide) WINDCODE W4 Garage Door https://www.floridabuild, ing.org//P r/pr app dtl.aspx?paratn=wGEVXQw-tDqv'yVVKJZIQ... 2/1"018 Florida BuildinG Code Online Pa'-e 5, of 6 Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +25 PSF/-32 PSF Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.4 FBC). Certification Agency Certificate L' 279 Pa_fC_CAQ Lgtter with woof of contract and roof gLinsp"echQp ffn --k-O L-_5_2-/Q _RS_C -AC W4 L shng Intertek -,.df Quality Assurance Contract Expiration Date 05/21/2028 Installation Instructions Verified By: Intertek Testing Services NA, Inc. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 15279.15 015 W4-16 DSIE-1F171: 4300, 2" Double -skin Insulated EPS (exterior skin 27 ga. min,; 4301, 4310, 4400, 4401, HDG, interior skin 27 ga. min.) Double -Car (9'2" to 160" wide) HDGL, HDGF, 66, 66G, 67, 67G, WINDCODE@ W4 Garage Door 68, SP200, SF200, SE200, 6200, 1620!,6203 Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +25.5 PSF/-25.5 PSF Other: The standard glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. 15279.16 016 W4-16 DSIE-IF471: GD2SP, GR2SP, GD2LP, GR2LP, AR2SP, AP2LP, ED2SP, ED2LP, 4302, HDGC, 6202, SFC68, MFC68 Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +25.5 PSF/-25.5 PSF Other: The standard glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. 15279.17 017 W4_16 DSIEO-11`479: I Coachman/Settlers/Affinity Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +25 PSF/-25 PSF Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.4 FBC). 15279.18 018 W4-16 DSIU-1F171: 9200, 9201, 9203, HDP20, HDPF20, HDPL20, 7200, 7201, 7203, 8200, j8201,8203 Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes . Impact Resistant: N/A Design Pressure: +25.5 PSF/-25.5 PSF Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1,4 FBC). Certification Agency Certificate CAC teL with p rk ntrj and prpef of insoegt,onf FL15279 P5 C CA W4 Listin rterfpk ndf Quality Assurance Contract Expiration Date 05/21/2028 Installation Instructions FL15279 R, H 101 4,ql -R-P-, 1 3rif Verified By: Intertek Testing Services NA, Inc. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: Gallery/ Artistry/Expressions: 2" Double -skin Insulated EPS exterior skin 27 ga. min.; interior skin 27 ga, min,) Double - Car ( 9'2" up to 16'0" wide) WINDCODE(D W4 Garage Door Certification Agency Certificate F 1 27C, L ih _j9Lga[_9 W.5- _fj.;gp_proof 2Li - jatZLin_n_Ddf Quality Assurance Contract Expiration Date 05/ 21/2028 Installation Instructions LL15219 _ E_' !C 4 9-B-Rev VDcff, aVerified By: Intertek Testing Services NA, Inc. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: Double Skin Insulated EPS (exterior skin 27 ga. min.; interior skin 27ga. min.) with Overlay Double -Car (up to 16' 0" wide) WINDCODE,8 W4 Garage Door Certification Agency Certificate ELL S27a_R5C CA Letter with pool of contract and r of 9UD' 5P&'gt!_QD_P1f Quality Assurance Contract Expiration Date 05/ 21/2028 Installation Instructions Verified By: Intertek Testing Services NA, Inc. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: Double - skin Insulated PUR (exterior skin 27 ga, min.; interior skin 27 ga, min.) Double -Car (9'2" to 16'0" wide) WINDCODE@ W4 Garage Door Certification Agency Certificate FLL5272 RS C CA!: Quality Assurance Contract Expiration Date 05/ 21/2028 Installation Instructions Verified By: Intertek Testing Services NA, Inc. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: htps:/,, N\v.loridabuildin=.orL"pr;' r- app dt.aspx"paran=A=GEVXQNtDqv3vVVKJZIQ... 2/l/2018 Florida Building Code Online Pac,Z:e 6 of 6 15279.19 019 W4-16 DSIUO- IK479: Canyon Double Skin Insulated PUR (exterior skin 27 ga. min.; Ridge/brookstone interior skin 27ga. min.) with Overlay Double -Car (9'2" to116'0" wide) WINDCODE@ W4 Garage Door Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +25.5 PSF/-25,5 PSF Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.4 FBC). 15279.20 020 W4-16 PAN-2F153: 73, 1500, 75, 190, 84A, 94, 42, 48, 55, 4RST, 6RST, 4RSF, 6RSF, GD5S, GD5SV, GRSS, GR5SV, AR5S, AR5SV, ED5S, ED5SV Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ. Yes Impact Resistant; No Design Pressure: +24 PSF/-24,5 PSF Other: The standard glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. Go to Page = 40 Certification Agency Certificate E L 15279 Pq CAC L roof QL I,,) U I n f Quality Assurance Contract Expiration Date 05/21/2028 Installation Instructions F:L15279_R5_II IQ_4457-,Rev02.pdf Verified By: Intertek Testing Services NA, Inc. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: Steel Pan (min. 25 ga.) Double -Car (9'2" to 16'0" wide) WINDCODE(& W4 Garage Door Certification Agency Certificate of f QLinsat ,ti nf Quality Assurance Contract Expiration Date 05/21/2028 Installation Instructions EL15279 PS 111 Verified By: Intertek Testing Services NA, Inc. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: back Next7, 40 Ild Page I / 8 0 0 Laajagj a5&-_4 7 4 _ :: 2kQj&lj11 jj nT 11 h ELjn&_ The State of Florida IS an AAJEEO employer. Con—oht 2007-2013 Stptl_QLF19 n :: Privacy Siat m n :: :: Rgfv.2Stamen[ Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please Contact 850.487.1395, 'Pursuant to Section 455.275(l), Florida Statutes, effective October 1, 2012, licensee$ licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emats provided may he used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click D&rf, Product Appro al Accepts: M U l FR MT C,,edCard Safe https:,//«!-, A,-w.floridabuildino,.or "pr/ r_ \N app_dtl.aspx?param=GEVXQNk-tDqv3,VVKJZIQ... 21/1/2018 c P NDPE1. 4F H FEDSH CARRIAGE 1Es14E' RAISED PANES. EKDO$3 DRms NfIDEEs I n DA n G4 On mwAY GDSS, Gm5 . lV11EAT' Gns GRIliv 1 TasARTISTRY' AASs AASSY T:NDHNI HVJSE' EDSs EDSSV mossl= 0 A MAX. DOOR VIM - 1 Q1445tC' SHORT R,NS PAHEE S4KfNN. 'C.KNADE HOL v MOM RNSED-PVNl IS ALSO APPROVED. wt/sl SHEETALSCRETS u APPNO SOREA9 O L DA fN0 HNRS 11LB1 M£AY£DMTE 1R11Df At<w 'e• rLa 'L• SEE SHEET TWO FOR IMPACT RESISTANT CONSTRUCTION DETAIL "A" AND STANDARD CONSTRUCT DETAIL "B"; TRACK AND JAMB DETAILS. REV DATE DE: SHEET 1 OF 2 Do 11/ao/o2 ADDED DCT04DED HOOIfT% 10 D8/08/ ADDED WIN 429. 486. 559 OPTIONAL GLAZING MAY BE STANDARD OR IMPACT 115 14/2012 RESISTANT GLAZING. SEE SECTION B-B FOR DETAILS. NIERs Arz siRts TsEE THEE roR MAX. STANDARD SIZE IS 42-1/2'X76'. IMPACT RESISTANT GLAZING IS 21-5/8'x14-1/8'. UIaTwE .+lk {+DN9 p ININA 2-1-2i U-SLEA -t-2-1 PATTVNE 1LD D-6va ON SECOON, ONE u-avls oN NEIR iECDPN. TIC.) 24 as tAE EINI ATTAOHED DDDR R PAi ED TO OStBfM POP. DaInwa CEYEN). uw wA 4a E 9!SOTS) TMD stDtlRiNr= =M NN°ne s nsi sNaSNIP LAP , KNNfs.- OPDRNY oumm NEYW t XN POSITION am.00Mnoax xuv MGM ENG04MR: MARK WMTEAFIVA P,E FLORU P, F- #46495. INC P. E.. /2? TEXAS P. E. 1912513 If DENSITY POLYSTYRENE FOAM INSULATION 1-5/ 18' THICK WITH VINYL HNRCELL BACKER (INSULATED MODELS ONLY) 25 GA MIN. GALV. STEEL SKIN WITH A WED -ON PRIMER, AND A BARED -ON POLYESTER TOP COAT APPLIED TO BOTH SIDES OF STEEL SKIN. 1N8 DV. f1 YEETS DA OxYEA Dn: nE9r. D>+Da FDA LE iATAH rrto sPffiB DSiD DOw KCPplO W THE ROAM tpx n Rc NTTTav+owE MDw c E LSL'TD Dn Avn-tD) son nn: sauaxne mepno4 0 Da44RFD DIRDeW, 2) ODED NASCf Rom N eAaMFY Do ZGIG A 1 ADm L AND 4) TESMN Al sooNmLBY LAN AHR 1O0. BY9H-„" CNOtARiB AnNnRDHrar cssxw M4 PRxaE TDEATE >Ii>m sPEo xrrw m 00 ly EXPORlx LATEIDH ww H[DiiT er Nr 4S' sr sP IMPACT RESISTANT OPTION. SECTION A -A { SLOE VIEW) I 1- 2' THICK glepaMPC: PAN-2F153 DATE, 1/3/97 Building Products BMASON, 0— H 4o mAvN By, JACCOTT1 ar (513) 770-4800 CHECKED BY, C" CR rR6«+ AD m9na ft_n . MWW VROWAL 1 §27' 9 3' TALL U-BAR 20 GA. GALV. STEEL MIN. YEILD STRENGTH: 50 KSI 3. T 12 CA GALV. STEEL TOP ROLLER BRACKET. EACH BRACKET ATTACHED W/(4) 1} 14-5/8' SHEET METAL SCREWS. 14 GA. GALV. ROLLER HINGE. EACH HINGE FASTENED TO END STILES WITH (4) /14x5/8' SHEET METAL SCREWS AND (4) 1/4'x3/4' SELF TAPPING SCREWS. SEE VIEW V. 3' TALI . 20 GA, GALV. STEEL. U-BARS IN A 2-1-2-1 PATTERN (I.E. TWO V-BARS ON BOTTOM SECTION, ONE U- BAR ON NEXT SECTION, ETC.). EACH U-BAR ATTACHED WITH (2) 1/4'.3/ 4' SELF TAPPING SCREWS PER STILE LOCATION. 13 GA. GALV, STEEL BOTTOM BRACKET. ATTACHED WITH (2) /14.5/ 8' SHEET METAL SCREWS. LUMINUM EXTRUSION vwn WEATHERSTRIP. DESIGN LOADS: +24. 0 PSF do -24.5 PSF TEST LOADS: +36.0 PSF k -37.0 PSF VDIDITTAP #ATM MAX, DmR SIZE, VV 4 1 16AO'Y,' . 16'D"H SCRIPTIDH CLASSIC AND CH RP STEEL PAN DOUBLE -CAR, 16'W 4, 24/-24.5 PSF 7xLAVDKi MNBERV VERB 3 101711 IBC St Olt Ar[t OBIDA IA n l TAAAlA2 HWSE' AAISED PANEL EM24SS DOORS iffiELS 25 W Z7 G Dff CLD'AY SD55, I 6USSY, OKtERY• OTSSY 131£x aanxTRr ARSS AR9SY mwO T WA E HUM' IDS m5sv a01 ma" SExTAOH3 # 6 U-NAS w nwm,Y. I.P m 7'ff6 xnuNwa S/a'wJ' W SCAflis OH 24 CEYaAS. i-1/0' O.D. MASIKR AEOlE1RD. LV TY TO 0"9' 5 BOW" MAY RE CdAak'.AStAet IBM 110f REWfUD) m PRUAK A RM TV m 10•E' 6 1WWONC SUIaaCE ,WPo20HTAL 1YK5 W Ha 1PIWsiER IAtO. C9' m LET 2'a' TO 14.0' 1'J' 0 fY9' 09 N14 JJa'O' SIEM IMO,tlR 9%]5 ON 39' CERIFR9 {2.OM PSI Ya. ONCKM MYOR MAX 1/4'.r TAPODY SCREYS al 1T' CENifT6 {20W PY! YN. COKKPEI 9R 9' DE1raR5"—), r B. VASiKRx AEDUatD •1TH TA C018. ANCHM WY RE idR IWi RE 110 PRMDE A nXW 1DI1NIYr4 5N0'ACE. ROKZOMTK .4YB5 OD YOf IWV79iM 14TER TO WSW TDS-101. A 110ENSfD DESiar PRa135,Ottl YAT ALSD !£ FYPEOr1D 10 APNiQK At1ETiRAti nslEiars nm/oR .r. caeWurtcTR. PREVARnYw a AYE RY anRas SRW YdWD9N0 RY DOOR #a,1HLEA (iD STAO M YaL WLY. Sall UW SRtE 24 TT210,1 Po4 Ay0 TO RA DIEM. sTEEt NfER 511LE IMPACT RESISTANT ASSEMBLY DETAILS DAA1MNEi 101711-A SECTION B-B (IMPACT -RESISTANT GLAZING OPTION) 1r CWRaIUl OECARITl.E —AL!— MRIiRMaJE INN BOIp TJSS JYv-a #rswT. • fAfl gi+ 31VAK Aw 2N'ASQ. ODRIYat H2Oilf AAGa. aAKaK :nANr DEn sa21 >tiw M0 MAO, AVAcr 1aJarwa a iLY.N A0.TaItta11E Prrr+ilA iAsIEN[D W TR.YE 1#TN ain4xzl 11cNr 41a> ro . Jir rn+ mrR nwwaiE JaEYs. rAAYE A aAm, DOOR ASSEMBLY NSTALIED a C016'lxY10E tY1TH TMS SEC110N YEETJ 111E STANDARD ASSEMBLY DETAILS OAAWING 1 01 71 1 -B SECTION B-B (NON -IMPACT RESISTANT UaING OPTION) ROW FWE YWM UN, COATNO OH OUTSIY SMACG YJTE THAT ER w EAAYE 6 nl%w R 1w Yi Na TMYE i.e5 aAD1D Mum MOE Um MAWN ro/4" PAN i1F.10 SCREW. STANDARD ASSEMBLY CONSTRUCTION: OPaWitL ssa m m f /A' K'Yfa1C LR#9 AYAlABtL OPiWH51 ACRYDC . rs LASIIOERE S1 OR 1UCTIE CP A 1'"" = AAS N ADWM#CE 1 H NC/1'9C 2000. THE ENTWIE DOOR ASSUALY It5T W N CONPLAKE ATiH THIS sEC 11EET5 m K f RE6U111]"m OF TIK f1A9A.A OL40M CODE OR NRHLATMk CODE NW 09CL 1M$ i M7 THE 86ACT REJtx1ANT REOAARDM iOR OFIRi15 AE91grs IKs. aY TER ,e sTec/rec). SHEET 2 OF 2 VY+ 54!¢A' N 1 /0 W OPLY. IEiI EACIi CK BRACIET. tAJlJE fASiDKO TD STREJ Ila As1nK0 m 14 aA OKv. RCEIAA taaE. Air.N 1RAE I aluDaTs. AAsiaxO m EYW anfa wiH iQ f BRKAKI /14ra%0' SiEEt 1KTP4 SCAinS A!A {4) 1S A MITS 1/4'wJ/4" Sf1A IMPEiU ATKYis. @A iMT1 Y' 90 NVL JFIORf S1EL J1EF2 ROISFR NRN STiiFl (#1 NTLON TIK BOX THE mm a THE suppR SIRUCR k QEYim9 S K THE f* S-0.salm a OK rnaESsaRn m RECOflD mR TIK E1mDRrD OR STAUCT4m A0 N ACCOROvief T amwea RUA#W com MA TTK irons Llre m THE ORAABW. aax w Oaooq. ENGINEER: MWN WESTERFK).D, RIM P.E. #4 5, P. E. %23132, AS P.E. #91513 Clapay Ilding Products MAsON°D{K 4Z5040 mnnnv ( 513) 770-4800 hQTE; TRACK CONFTGURAnON ABOVE THE DOOR OPENING DOES NOT AFPECT Tif WIND LOAD RATING OF THIS DOOR, IOTa2ONTK ' TR+lxt SL1RY m (TO090RNST/i1EJt SlWO a' TAil Di%Ni5 iVD UNOEA n ra cKv. sTm rTna eRuxEr, AJLTr 10 wnoo .YAiB r1TH t31fl TOP BRACKET DOi78LE HORIZONTAL TRACK V. i-5i J) 5/1e•./a' w o0 IAn scREm. E 2' Giv. S1EEL W. oDti_n lA'ILt1F- AaRQ+al,{ oP)xiN L. d19i. 7RALK WK.2m AW - qj7YP. 2- 1/ 1•a12 fA GiLY. STFti iRACM N!K'J(Ei. 6 (4) iRKX BRMAEis PER '90E ag)E; hvmm ocAlat TRArx 1nw LTArm &MAM u HOAQOItIK TAACJ( S1A' hWi BY DOOR MiAt1E11 TDO 3U10 DOa6 WTA 0' At1 '. 13 oA oKv. san nAo aBRAaT. f3Oi rASTn1ED m iv000BRIOET. awa 2' NYLY. Sail TRACA. F iR4OK 7NiC%i&6S A0O' YN. 8 {6) TAAG( aRncKcts PEn s> oE w m u wart. ',.....,. NSiNJCE EEiWAUN n.W A1AD IRALAI BRAL'itE! qOT m EKCFID Be O. G a= iDR DOaR P1R T.' 12'-0' 1SOT1. TRACK P a PAM I.YfYIAr FAM EXCUMM11. CMSLLT AACNRYSatxrOREm- d RCO. Ylly DESIGN LOADS: +24.0 PSF & - 24.5 PSF TEST LOADS: +36.0 PSF h -37.0 PSF C: PAN-2F153 WML34D RA TO RAx DOM srzE, W 4 16.0-W K 18'0-H 1/3/97 IESC11PT1011 CLASSIC AND CH RP STEEL PAN IN BY, JAC DOUBLE -CAR. 18'W +24/-24.5 PSF KED 0Y, 1YHALVG MAILER+ VER, MWW 101711 18C Florida Building Code Online Page I of 4Z11 K 7 u 5CIS Home Log In User Registration hot Topics Submit Surcharge Stats, is Facts Publications FeC Staft, KITS Site Map Links Search JA ,j,'.T. P,ro.duct Approval ublicUserdb- ProducA r val Menu > Product or ;,policqL.On ;torjh. I Aw 00 L,i9 > Application Detail FL # FL17499-P3 Application Type Revision Code Version 2017 Application Status Approved Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Certification Agency Validated By Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved MI Windows and Doors 650 West Market Street Gratz, PA 17030 717) 365-3300 Ext 2560 bsitlinger@miwd.com Brent Sitlinger bsitlinger@miwd.com Windows Single Hung Certification Mark or Listing American Architectural Manufacturers Association Steven M. Urich, RE R.I. Validation Checklist - Hardcopy Received 514DAWA AAMA 506 AAMA/WDMA/CSA 101/l.S.2/A440 AAMA/WDMA/CSA 101/l.S.2/A440 Method 1 Option A 01/15/2018 01/15/2018 01/21/2018 Year 2011 2008 2011 htips:ll,N-w,w.floridabuildinc,.org,lpr,lpr_,-tpp_dtl.aspx?parain=wGEVXQwtDqtCUG-,,jQiz6B... 2/1,12018 Florida Building Code OnlineZ7- Page 2 of 4 Summary of Products FL j Model, Number or Name Description 17499.1 185 SH 36x84 Fin/Flange Frame IG/SG Impact Single Hung Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL17429 R C CA!: MI Wind ws - I c H 'Fin Im act Approved for use outside HVHZ: Yes j)_pdf Impact Resistant: Yes FlU7499 R3 C C.AMI WinQws; - 18S SH (Fin) L51 Design Pressure: +55/-55 Qa0e If Other: R-PG55*, Missile Level D, Wind Zone 3. Glass to be ELI:/:4 9P,3_C A- MI Windov Es,- 85SH 'ftAaqemLLIac _p beddedin Pecora 896 sealant. LID-Pif F! 17499 R3 CAC MI Windows B5- r-1Flanqft)_ImaQc Quality Assurance Contract Expiration Date 10/17/ 2018 Installation Instructions r:L174P H 08-0254-B df Verified By: Luis R Lomas PE-62514 Created by Independent Third Party: Yes Evaluation Reports FLI 74` 3_qR Created by Independent Third Party: Yes 17499.2 185 SH 52x72 Fin/Flange Frame IG/SG Single Hung Laminated Glass Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FLU 7499, RA': AP Approved for use outside HVHZ: Yes SH(FL(,-- waiver),cdf Impact Resistant: No f!.;_74qa_.E.j_ t!jj \6 ino L .!j Fin f C- - _. _5_5 _L_jCW_pA_ Design Pressure: +60/- 60 fL12A2_LU3t_LFinl LLZjp f Other: R-PG60 FL174 9 P C CACMI Vvinrin-q - !RSH LIDL2d f Quality Assurance Contract Expiration Date 10/08/2018 Installation Instructions 08- Verified By: Luis R Lomas PE-62514 Created by Independent Third Party: Yes Evaluation Reports FI-17499 R3 AE Created by Independent Third Party: Yes 17499.3 185 SH 136x84 Fin/Flange Frame IG/SG Single Hung Laminated Glass Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL17499 R3 C AARC (13363)EjZ2,9. Approved for use outside HVHZ: Yes vav&-r)z.0! Impact Resistant: No Fi 17499 R-) C CAC M Wind W Design Pressure: +60/-60 FL17429 R3 C CAC MI Window ',Rl SH iFin) Other:R-PG601 FL17499 R3 C CAC MI Windows - 1 5 H F1 n Ll L-P qf Quality Assurance Contract Expiration Date 10/17/2018 Installation Instructions FL17499 R3 11 08-02550B. oclf Verified By: Luis R Lomas PE-62514 Created by Independent Third Party: Yes Evaluation Reports Created by Independent Third Party: Yes 17499.4 185 SH 36x71 Fin, Finless, Flange Frame IG Single Hung Limits of Use Certification Agency Certificate Approved for use in HVHZ: No Approved for use outside HVHZ. Yes Impact Resistant: No Quality Assurance Contract Expiration Date Design Pressure: +60/-67 04/ 25/2022 Other: R-PG60* Installation Instructions fL_7429 P3 1 -_01 6- -, f Verified By: Luis P. Lomas, PE PE-62514 Created by Independent Third Party: Yes Evaluation Reports Lr,_.74 QR' AEI; 140 82ndf Created by Independent Third Party: Yes 1 17499.5 1185 SH I 52x72 Fin/Flange Frame IG/SG Impact Single Hung I Limits of Use Certification Agency Certificate Approved for use in HVHZ: No f; 1 q 3 7 1. C N11 n oApprovedfor use outside HVHZ: Yes ii, df Impact Resistant: Yes C MT L17499 R3 C CA Wind w 'Fin)_jnp_rt 1-ittps:%/Nk,,,,,rw'.floridabuilding.org/ prlpr_app_dtl.aspx9parai,n=wGEVXQwtDqtCUGovjQiz6B... 21/1/2018 Florida Building Code Online Page 3of 4Z: Design Pressure: -55/-55 L- 11 d f Other- R-PG55, Missile Level D, Wind Zone 3. Glass to be Fl i _74q9 RI_E-_CAC MI YV 12dfbeddedinPecora896sealant. EL.I7499 P," im" art Quality Assurance Contract Expiration Date 10/10/2018 Installation Instructions I Z4_119,... 1.. 1 Lj - 4,& 1,.Q.0ff Verified By: Luis R Lomas PE 62514 Created by Independent Third Party: Yes Evaluation Reports I Created by Independent Third Party: Yes 17499.6 1 185 SH 52x84 Fin/Flange Frame IG/SG Single Hung Limits of Use Certification Agency Certificate Approved for use in HVHZ: No 185 Approved for use outside Hill Yes H_Cft-G waiver 5&tg I-8A 52 1-8 84 E! OO 1 8) d fp— Impact Resistant; No F.t.L74 cl R.3C Design Pressure: +60/-60 Other: R-PG60 Quality Assurance Contract Expiration Date 10/09/2018 Installation Instructions kj7400_Rj 11 03-2LS4ff-2_pdf Verified By: Luis R Lomas PE 62514 Created by Independent Third Party: Yes Evaluation Reports 74qq Created by Independent Third Party: Yes 17499.7 185 Triple SH --Till 1x72 Fin Frame IG/SG Single Hung I 10x72 Flange Frame G/SG Single Hung Limits of Use Certification Agency Certificate Approved for use in HVHZ: No EL17499 R3 C CAC MI Windows 18S SH Trinip LElnj Approved for use outside HVHZ: Yes Impact Resistant: Na Q)-of Design Pressure: +50/-50 L4LO-1 Other: R-PG50* I noel Quality Assurance Contract Expiration Date 10/20/2018 Installation Instructions E 17A22_E_3 :I 48m024$E.:.Pdf7 Verified By: Luis R Lomas PE 62514 Created by Independent Third Party: Yes Evaluation Reports Created by Independent Third Party: Yes 17499.8 185 Twin SH 106x72 Fin Frame IG/SG Single Hung 105x72 Flange Frame IG/SG Single Hung Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL17499 P,3 C CA M Win ws - 'Pr `H Twin (Fm LILApprovedforuseoutsideHVHZ: Yes Impact Resistant: No FL17422 P," C CA- M Win ow 18 M Twin Fin Design Pressure: +45/-45 Other:R-PG45 FL17499 R3 C CAC MI Window 185 SH Twin (Ftnael ci)- pj ' I Quality Assurance Contract Expiration Date 10/ 20/2018 Installation Instructions Verified By: Luis R Lomas PE-62514 Created by Independent Third Party: Yes Evaluation Reports 7kdf ELI7491: _ 9_P,3_A_ 51"'Z2L- Created by Independent Third Party: Yes back Next lootact Qs :: 2601 Blair Stone Road. 1a F i9 EL2-n2.: 9 -47- 24 The State of Florida is an AA/EEO employer, Copyright 2,W7-201 3 St Florl L :: aUvaC Statement :: :: BgLU-Q m n p bttps:,',',A-\7,,v.floridabuildin,cy.or--,,'p r/ r app dtl.aspx?parani=wGEVXQA,-tDqtCUGg\jQiz6B... 2/1 1 /"/- 0 18 Florida Building Code Online Page 4 of 4 Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records reques-, do not send electronic mail to this entity, Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850,487,1395, 'Pursuant to Section 455,275(l) Florida statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they h ave one. The t emads pofficial providedmaybeusedforocialcommunication with the licensee. However emaii addresses are public record, it you do not wish to supplysuppa personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click ntM, Product Approval Accepts: 771 U i l EE M credt Card safe hrtps:/',`/, A-\ 7,-w.floridabuildina.orglIP r,lpr app dtl.aspx?paran-i=wGEVXQNA,tDqtCUGa,jQiz6B... 2/1 /2018 Z' I NOTES: 1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH REQUIREMENTS OF THE FLORIDA BUILDING CODE. 2, WOOD FRAMING AND MASONRY OPENING 70 BE DESIGNED AND ANCHORED TO PROPERLY TRANSFER ALL LOADS TO STRUCTURE. FRAMING AND MASONRY OPENING IS THE RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. 3, IX BUCK OVER MASONRY/CONCRETE IS OPTIONAL, 4, WHERE SHIM OR BUCK THICKNESS 15 LESS THAN 1-1/2- WINDOW UNITS MUST BE ANCHORED THROUGH THE FRAME IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS. ANCHORS SHALL BE SECURELY FASTENED DIRECTLY INTO MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE MATERIAL. S. WHERE WOOD BUCK THICKNESS IS 1-1/2" OR GREATER, BUCK SHALL BE SECURELY FASTENED TO MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE. WINDOW UNITS MAY BE ANCHORED THROUGH FRAME TO SECURED WOOD BUCK IN ACCORDANCE WITH MANUFACTURER'S PUB[ SHED INSTALLATION INSTRUCTIONS. 6, WHERE YX BUCK 15 NOT USED DISSIMILAR MATERIALS MUST BE SEPARATED WITH APPROVED COATING OR MLMORANE. SEL.ECTJON OF COATING OR MEMBRANE IS THE RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. 7. BUCKS SHALL EXTENT) BEYOND WINDOW INTERIOR FACE SO THAT FULL FRAME SUPPORT IS PROVIDED. 8, FOR FIN INSTALLATION SHIM AS NEEDED. FOR FRAME INSTALLATION SHIM AS REQUIRED AT EACH ANCHOR LOCATION WITH LOAD BEARING SHIM. SHIM WHERE SPACE OF 1/16" OR GREATER OCCURS. MAXIMUM ALLOWABLE SHIM STACK TO BE 1/4". 9. SHIMS SHALL OF LOCATED, APPLIED AND MADE FROM MATERIALS AND THICKNESS CAPABLE OF SUSTAINING APPLICABLE LOADS, 10, WIND LOAD DURATION FACTOR Cd=1.6 WAS USED FOR WOOD ANCHOR CALCULATIONS. 11. FRAME MATERIAL: EXTRUDED RIGID PVC. 12, UNITS MUST BE GLAZED PER ASTM E1300-04/09, SEE SHEET 11 FOR CLASS DETAILS, 13, APPROVED IMPACT PROTECTIVE SYSTEM l5_RRwMR D FOR THIS PRODUCT IN WIND BORNE DF13RIS REGIONS. 14, FOR ANCHORING THROUGH FIN INTO WOOD FRAMING OR 2X BUCK USE #8 WOOD SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4- MINIMUM EMBEDMENT INTO SUBSTRATE, LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. RFOS"qs tIESCRIpflo" I DATE I APPRgVED REVISED ANCHOR SPACING & CHARTS J O7f 11/16 REVISED GLASS 1 io/02/I R.L. 15. FOR ANCHORING THROUGH FRAME INTO WOOD FRAMING OR 2X BUCK USE #10 WOOD SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. 16, FOR ANCHORING THROUGH FRAME INTO MASONRY/CONCRETE USE 3/16- TAPCONS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4- MINIMUM EMBEDMENT INTO SUBSTRATE WITH 2 112" MINIMUM EDGE DISTANCE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. 17. FOR ANCHORING THROUGH FRAME INTO METAL STRUCTURE USE #10 SMS OR SELF DRILLING SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE 3 THREADS MINIMUM BEYOND STRUCTURE INTERIOR WALL. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. 18. ALL FASTENERS TO BE CORROSION RESISTANT. 19, INSTALLATION ANCHORS SHALL BE INSTAL LED IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BELOW: A, WOOD: MINIMUM SPECIFIC GRAVITY OF G=0,42 B. CONCRETE: MINIMUM COMPRESSIVE STRENGTH OF 2,000 PSI. C. MASONRY: ITOLLOW/FILLED BLOCK PER ASIM C90 WITH Fm=2,000PSI MINIMUM. D. METAL STRUCTURE: STEEL 38GA (.048") FY=33KSI/FU=52KS1 OR ALUMINUM 6063-15 FU=30KSI .048" THICK MINIMUM TABLE OF CONTENTS SHEET NO, I DESCRIPTION IT NOT --ES_'__________ 2 3 ELEVATIONS 4 10 INSTALLATION DETAILS 11 1 COMPONENTS SIGNED: 1211412017 MI WINDOWS AND DOOSTREETRS, LLC ETTMA650WESRK 1. L O'//// GRATZ, PA 17030-0370 5ISERIES185ALUMINUMSINGLEHUNGWINDOW 52" X 72" NON —IMPACT NOTES S7AT OF DRAWN:. o REV N. G. 08-02549 9 A j/ IIIHIONSC_E NTS 19" 12/29/14 1 S"E'T 1 OF 11 L. ROSERTOLOMASP.E Luis R. Lomas P.E. 1432 WOODFORD RD LEMSVILLE, NG 27023 FL No.: 62514434-6M 0609 0—sC.)W-,pe — 52" MAX FRAME W;t)Tf I 2" MAX 16" MAX O.C. 2- MAX 2" MAX 2" 16" 16, MAX J MAX 0, C, O.G. 72" T_ 72" MAX MAX FRAME FRAME HEIGHT J HEIGHT 1J Q 1. R£ SONS 52" MAX FRAME WIDTH A fZEI/;SFD ANCHOR SPACING & CHARTS 07111116 R L. 16" MAX O.C. 2" MAX -- - -----------_- 9 REVISED GLASS 10102117 R. L, 185 ALUMINUM SINGLE HUNG WINDOW 185 ALUMINUM SINGLE HUNG WINDOW DESIGNER EXTERIOR VIEW FLANGE & FINLESS INSTALLATION FLANGE& FINLESS INSTALLATION SEE CHART # I FOR SMALLER UNITS REQUIRED ANCHORS SEE CHART # I FOR SMALLER UNITS REQUIRED ANCHORS DESIGN PRESSURE RATING IMPACT RATING i&O.OPSF NONE NOTES: S: 1, MAXIMUM SASH S17F: 51" X 36" 2. MAXIMUM SASH DJ_O,: 47 5/8" X 32 1/2", 3. MAXIMUM FIXED V,L,0_ 49 3/8" X 32 1/2", HARDWARE SCHEDULE METAL SWEEP LOCK AT 8" FROM EACH END INTERIOR MEETING RAIL BLOCK AND TACKLE BALANCE AT JAMBS CHART#I Number of anchor locations required Frame Frame Width (in) Height 18,00 1 24.00 30,00 36.00 1 42.00 48.00 52.00 in) Head Jamb Head Jamb Head Jamb Head Jamb Head Jamb Head JambHead Jamb 24.00_ 2 3 3 3 3 3 3 3 4 3 4 3 4 3 30.00 2 3 3 3 3 3 3 3 4 3 4 3 4 3 36,00 2 3 3 3 3 3 3 3 4 3 4 3 4 3 4200Z_ 2 4 3 4 3 4 3 4 4 4 4 4 4 4 48.00 2 4 3 4 3 4 3 4 4 4 4 4 4 4 54.00 2 5 3 5 3 5 3 5 4 5 4 5 4 5 6&00 2 5 3 5 3 5 1 3 5 4 5 4 5 4 l) 66.00 2 5 3 5 3 5 3 5 14 5 4 5 4 5 7200 1 2 6 3 6 3 6 3 6 1 4 6 4 4 6 MI WINDOWS AND DOORS, LLC 650 WEST MARKET STREET GRATZ, PA 17030-0370 SERIES 185 ALUMINUM SINGLE HUNG WINDOW 52" X 72" NON —IMPACT FLANGE & FINLESS ELEVATIONS DRAWN DWG Aip. N.G. 1 08-02549 TS 1"" 12/29/14 1 S"'I" 2 OF 11 I ROBERTOLOMASPE 1432 WOODFORD RD LEWISVILLE, NC 27023r4346880609 SIGNED. 1211412017 0t I I I I I I I 2C, P, 0 4f BENS OFfAi 0t4AL1" I III I 110 Luis R. Lomas P.E. FL No.: 62514 52" MAX FRAME WIDTH 2" MAX 10" MAX O.C. 2" MAX 2" MAX — 2- 10" 10" MAX 0 c MAX O.C. 72" 72- MAX MAX FRAME FRAME I I r I G J, I I HEIGHT 52" MAX FRAME WIDTH 10 MAX O.C. 2" MAX 4 X REVISED ANCHOR SPACING P, L REVISED GLASS tOf021i7 R 1, CHART#2 Number of anchor locations required Frame Frame Width (in) Height 1&00 1 24.00 30.00 36 42.00 48.00 52,00 in) H & S I Jamb IH&S Jamb H&S Jamb H&S Jamb H&S Jamb H_&S Jamb H& S Jamb 24.00 3 3 1 3 3 4 3 5 3 5 3 6 3 6 3 30.00 3 4 1 3 4 4 4 5 4 5 4 6 4 6 4 3&00 3 5 3 5 4 5 5 5 5 5 6 5 6 5 42. 00 3 5 3 5 4 5 5 5 5 5 6 5 6 5 48.00 3 6 3 6 4 6 5 6 5 6 6 6 6 6 54.00 3 6 3 6 4 6 5 6 5 6 6 6 6 0,00 3 7 3 7 4 7 5 7 5 7 6 7 6 7 66,00 3 8 3 8 4 8 5 8 5 8 6 8 6 8 72.00 3 8 3 8 4 8 5 8 5 8 6 8 6 8 185 ALUMINUM SINGLE HUNG WINDOW 185 ALUMINUM SINGLE HUNG WINDOW EXTERIOR VIEW EXTER1013 VIEW FIN INSTALLATION FIN INSTALLATION SEE CHART #2 FOR SMALLER UNITS REQUIRED ANCHORS SEE CHART #2 FOR SMALLER UNITS REQUIRED ANCHORS DESIGN PRESSURE RATING IMPACT RATING 60.OPSF NONE NOTES: 1, MAXIMUM SASH SIZE: 51" X 36 2. MAXIMUM SASH D1,0. 47 5/8" X 32 1/2". 3 MAXIMUM FIXED D.L,O.: 49 3/8" X 32 1/2". HARDWARE SCHEDULE METAL SWEEP LOCK AT 8" FROM EACH END INTERIOR ME BLOCK AND TACKLE BALANCE AT JAMBS SIGNED: 1211412017 MI WINDOWS AND DOORS, LLC 650 WEST MARKET STREET 04' GRATZ, PA 17030-0370 0,6 5SERIES185ALUMINUMSINGLEHLINGWINDOW 52" X 72" NON —IMPACT p'// FIN ELEVATIONS zrOF RDRAWN NG, 08-02549 Luis R. Lornos P.E. SCALE NTS I LATE 12/29/14 1 S""'T 3 OF 11 L. PORERTO LOMAS P.F. 1432 W)ODFORV RD LEW)SVILLE, NC 27023 FL NO.: 625144346880609 112" DIN EDGE DISTANCE A RCqSF0 ANCHOR SPACING A, CHARTS WOOD FRAMING OR 2X BUCK 6 REVISED GLASS BY OTHERS 1 1/4" MIN, EMBEDMENT BACKER ROD 1/4" MAX. APPROVED SEALANT SHIM SPACE 1 1/4" MIN, 1/4" MAX, 10 WOOD SCREW EMBEDMENT HIM SPACE 112" INTERIOR MIN EDGE INTERIOR DISTANCE 10 WOOD SCREW WOOD FRAMING EXTERIOR OR 2X BUCK BY OTHERS BACKER ROD APPROVED gXTERIOR SEALANT JAMB INSTALLATION DETAIL WOOD FRAMING OR 2X BUCK INSTALLATION BACKER ROD APPROVED SEALANT WOOD FRAMING OR 2X BUCK BY OTHERS VERTICAL CROSS SECTION SILL To BE SET IN A BED OF APPROVED STRUCTURAL SEALANT 1/4" MAX. SHIM SPACE WOOD FRAMING OR 2X BUCK INSTALLATION JIJO TIES, 1, INTERIOR AND EXTERIOR FINISHES, BY OTHERS, NOT SHOWN FOR CLARITY 2 PERIME7 ER AND JOINT SEALANT BY OTHERS TO BE DESIGNED IN ACCORDANCE WITH ASIM E2112 MI WINDOWS AND DOORS, LLC 650 WEST MARKET STREET GRATZ, PA 17030-0370 SERIES 185 ALUMINUM SINGLE HUNG WINDOW 52" X 72" NON —IMPACT FLANGE INSTALLATION DETAILS DRAWN DWG I N.G. 08-02549 SCALE NTS IDATE 12/29/14 ISHEET4 OF 11 I ROSERTOLOMASPE 1432 WOODFORD RD LEWISVILLE, NC 27023r— 434-688-0609 flloMas PkkMaspe C-I IlAll AP. ROVc_p SIGNED: 1211412017 9 L 0 A rAT OF 0 ONA, Luis R. Lomas P.E. FL No.: 62514 EDGE DISTANCEr -- ---r 3/2" ""' STRUCIL) BY OtHE APPROVED SE ALANT 1/4" MAX. SHIM SPACE DESCRIPTION REVISED ANCHOR SPACN'G & CHARTS REVISED GLASS 1/4" MAX. SHIM SPACE 10 SMS OR SELF DRILLING SCREW 10 SMS OR INTERIORINTERIORSELFDRILLING SCREWS 2 EDGE DISTANCE EXTERIOR METAL EXTERIOR STRUCTURE BACKER ROD BY OTHERS APPROVED SEALANT j H I JAMB INSTALLATION DETAIL ff METAL STRUCTURE INSTALLATION BACKER ROD APPROVED S[AtANI META STRUCTUR BY off ER SILL TO BE SET IN A BED OF APPROVED STRUCTURAL SEALANT 1/4" MAX. SHIM SPACE VERTICAL CROSS SECTION METAL SMUFTLIRE INSTA LLATION6N N07ES I.INTL-'RIOR,4NDEXTERIOR FINISHES, BYOT)iERS, N07 SHOWN FOR CLARITY. 2 PERIMETER AND JOINT SEALANT BY OTHERS 70 BE DESIGNED IN ACCORDANCE WITH ASTM E2112 MI WINDOWS AND DOORS, LLC 650 WEST MARKET STREET GRATZ, PA 17030-0370 SERIES 185 ALUMINUM SINGLE HUNG WINDOW 52" X 72" NON —IMPACT FLANGE INSTALLATION DETAILS DRAWN f NO, N. G. 08-02549 SCALE JATS 1"'E 12/29/14 1 SIIE11 5 OF 11 L. ROBERTO LEXIAS P E 1432 W"FORD RD LEWISVILLE, NC 27023 434- 686-0609 DATE AFG'R{ritEO DJ R.L. RA. SIGNED: 1211412017 9 L 0 f N r-% 14TAT OREY F0 Az - Luis R. Lomas P.L. FL No.: 62514 2 1"" ""' EDGE DISTANCE CCONCRF_I[IMASONRY BY OTHERS 1 1/4" OPTIONAL IX BUCK MIN. SEE NOTES 3 — 7 EMBEDMENT SHEET I 1/4"' MAX. BACKER ROD SHIM SPACE APPROVED SEALANT 3/16- TAPCON INTERIOR EXTERIOR 1 1/4" MIN. EMBEDMENT C()NCPi.TF/MASONRY SAY CT}4CPC 3/16" TAPCON REVISED ANCI40f? SPACING & CiIARIS REVISED GLASS 1/4" MAX. SHIM SPACE INTERIOR 2 112" MIN, EDGE DISTANCE BACKER ROD EXTERiOR APPROVED OPTIONAL IX BUCK SEALANT SEE NOTES 3 — 7 SHEET I JAMB INSTALLATION DETAIL CONCRETEIMAi(5 ih7Y-IFV§j A—L Ti6—L,Ni DATE AVPRWf0 NOTES: SILL TO BE SET IN A BED OF 1, INTERIOR AND EXTERIOR FINISHES, BY OTHERS, PACKER ROD APPROVED NOT SHOWN FOR CLARITY. APPROVED 3STRUCTURAL 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE SEALANT SEALANT DESIGNED IN ACCORDANCE WITH ASIM E2112 SIGNED. 1211412017 OPTIONAL IX BUCK 1L.. 1/4" MAX. MI WINDOWS AND DOORS, LLC SEE NOTE .3 — 7 X\\ 1 D 04f I'// SHEET I SHIM SPACE 650 WEST MARKET STREET GRATZ, PA 17030-0370 CONCRFiE/MASONRY SERIES 185 ALUMINUM SINGLE HUNG WINDOW 6 BY OTHERS 52" X 72" NON —IMPACT 7: FLANGE INSTALLATION DETAILS STATE OF ".. 0 LIRAWN _G - REV N. G. 08-02549 8 SCALE NTS 1"t 12/29/14 1 s"cc' 6 OF 11 VERTICAL CROSS-SECTION L, ROBERTO LOWS P E, Luis R. Lomas P.E. CONCRETEIMASONRY INSTALLATION 1432 WOODFORD RD LEMSVILE, N(327023 434-686-0609 FL No.: 62514 WOOD FRAMING OR 2X ElUCK BY OTHERS BACKER ROD APPROVED SEALANT BACKER ROD APPROVED SEALANT WOOD FRAMING OR 2X BUCK BY OTHERS 112" MIN EDGE DISTANCE 1/4*' MAX. HIM SPACE 410 WOOD SCREW SILL TO BE SET IN A BED OF APPROVED STRUCTURAL SEALANT 1/4- MAX. SHIM SPACE VERTICAL CROSS SECTION t'VOODFRAMING OR2XBOGRINSTALLATION NOTES: I INTERIOR AND EXTERIOR FINISHES,BY07HERS, NOT SHOWN FOR CLARITY, 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE DESIGNED IN ACCORDANCE WITH ASTM E2112 1 1/4" MIN EMBEDMENT I_ 1/ 2" MIN EDGE DISTANCE 10 WOOD SCREW WOOD FRAMING OR 2X BUCK BY OTHERS REVISKJNS REVISED ANCHOR SPACING & CHARTS REVISED GLASS 1/ 4" MAX, SHIM SPACE INTERIOR BACKER ROD APPROVED SEALANT JAMB INSTALLATION DETAIL WOOD FRAMING OR 2X BUCX INSTALLATION Ml WINDOWS AND DOORS, LLC 650 WEST MARKET STREET GRATZ, PA 17030-0370 SERIES 185 ALUMINUM SINGLE HUNG WINDOW 52" X 72" NON —IMPACT FINLESS INSTALLATION DETAILS DRAWN no N. G. 08-02549 NITS 1"' 12/29/14 1 S"" 7 OF 11 E L, ROBERTO LOMAS P , 1432 WOODFORD RD LEWISVILLE, NC27023 r431-688 0609 M,—C&W—sp, — TATF_ j APPROVED SIGNED: 1211412017 A\ ti ENq " k* cp p4TAT70_ F S, / ONACM'' Luis R. Lomas P. E. FL No,: 62514 2 112" MIN EDGE DISTANCE CONCRETE/MASONRY BY OTHERS OPTIONAL IX DUCK 14 1 1/4" MIN. EMBEDMENTSEENOTES37 SILEET I 1/4" MAX. BACKER ROD SHIM SPACE APPROVED SEALANT 3/16" TAPCON INTERIOR EXTERIOR 1 1/4" MIN. EMBEDMENT CONCRETE/MASONRY BY OTHERS 3/16- TAPCON 2 112" MIN, EDGE DISTANCE REVISIONS REVISED ANCHOR SPACINC, & CHARTS REVISEO GLASS OPTIONAL IX BUCK SEE NOTES 3 — 7 SHELF I 1/4" MAX. SHIM SPACE INTERIOR EXTERIOR BACKER ROD APPROVED SEALANT JAMB INSTALLATION DETAIL CONCRETEIMASONRY INSTAL LA PON SILL TO BE SET IN A 810 OF NOTES: BACKER ROD APPR.O VED 1, INTERIOR AND EXTERIOR FINISHES, BY OTHERS, APPROVED SEALANT STRUCTURAL NOT SHOWN FOR CLARITY, v SEALANT 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE OPTIONAL IX BUCK 1/4" MAX DESIGNED IN ACCORDANCE WITH ASTM E2112 SEE NOTE 3 - 7 SHIM SPACE SIGNED: 1211412017 SHEET I MI WINDOWS AND DOORS, LLC 650 WEST MARKET STREET 00 41 CONCRETE MASONRY A GRATZ, PA 17030-0370 BY OTHERS SERIES 185 ALUMINUM SINGLE HUNG WINDOW 51 52" X 72" NON -IMPACT 4 LTATa FINLESS INSTALLATION DETAILS -p 4 OF 0 DRAWN ""Z R 10' 0 VERTICAL CROSS SECTION TS 1' 12/29/14 08-025 9 OF 11 //01111111 j\\Ncomc_RETEaWA YINSTALLADON L.ROBER TO LOMAS P.E.Luis R. Lomas P.E. 14,12 WO()DFORD RD LEWISVILLE, NC 27023r "4.14 6,98-0609 FL No.: 62514 APPROVED SEALANT BEHIND FIN 7116- MIN EDGE DISTANCE 1 1/4" MIN. EMBEDMENT WOOD FRAMING BY OTHERS 1/4" MAX SHIM SPACE REVIStOtiS REV;SED ANCHOR SPACING & CHARTS REVISED CLASS WOOD FRAMING 1/4" MAX BY OTHERS ,HIM SPACE INTERIOR # 8 WOOD SCREW INTERIOR 1 1/4" MIN.. EMBEDMENT APPROVED SEALANT EXTERIOR BEHIND FIN 7/16" MIN EXTERIOR EDGE DISTANCE 7/16" MIN EDGE DISTANCE APPROVED SEALANT BEHIND FIN LIADLUPALN1 VERTICAL CROSS SECTION WOOD -- -6FRAMWO 'R2XfWWINSTALLATION JAMB INSTALLATION DETAIL WOOD FRAMING OR 2X DUCK INSTALLATION NOTES 1. INTERIOR AND EXTERIOR FINISHES, BY OTHERS, 1/4" MAX NOT SHOWN FOR CLAMI TY. SHIM SPACE 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE DESIGNED IN ACCORDANCE WITH ASTM E2112 Ml WINDOWS AND DOORS, LLC 650 WEST MARKET STREET WOOD GRATZ. PA 17030-0370 FRAMING BY OTHERS SERIES 185 ALUMINUM SINGLE HUNG WINDOW 52" X 72" NON —IMPACT FIN INSTALLATION DETAILS DRAWN: N G 08-02549 NTS I -TI 12/29/14 1 SHEET 10 or 11 L. ROBERTOLOMASPF 314 WCX)DFO,4?DRDLEWiSV;LtE,NG27tl23r42342688- 0609 dtomasPkl—,p— DATE 2/ 17 Rl 0 /f IL"6— - SIGNED: 1211412017 11 R, L TAT 0 IF Z 13 Luis R. Lomas P.E. FL No.: 62514 METALAt STRUCTURE BY OTHERS APPROVED SEALANT INTERIOR EXTERIOR BACKER ROE APPROVEC SEALANT METAL STRUCTURE SY OTHERS 112" MIN EDGE DISTANCE 114" MAX. SHIM SPACE S ORI, SELF DRILLING SCREW VERTICAL CROSS-SECTION METAL STRUCTURE INS TALLA 74ON NO TES I INTER)ORAND EXTERIOR FINISF4E,3,BYOTHERS, NOT SHOWN FOR CLARITY. 2 PERIMETER AND JOINT SEALAN7 BY OTHERS TO BE DESIGNED IN ACCORDANCE W17H ASTM E2112 SILL. TO BE SET IN A BED OF APPROVED STRUCTURAL SEALANT 1/ 4- MAX. SHIM SPACE REVISED ANCHOR SPAORG & CHARTS REViSE0 GiAss 1/ 4" MAX, SHIM SPACE 10 Sms OR INTERIOR SELF DRILLING SCREWS EDGE DISTANCE EXTERIOR METAL BACKER ROD STRUCTURE APPROVED BY OTHERS SEALANT JAMB INSTALLATION DETAIL METAL STRUCFUiiilNSiA!l7A jj7o N- MI WINDOWS AND DOORS, LLC 650 WEST MARKET STREET GRATZ, PA 17030-0370 SERIES 185 ALUMINUM SINGLE HUNG WINDOW 52" X 72" NON --IMPACT FINLESS INSTALLATION DETAILS ORAWN, NO, N. G. 08-02549 5c4" NTS JrATE 12/29/14 soleB OF 11 I ROBERTO LOMAS P E 14. 12 WO('.)DFORD RD LEWISVILLE, NC 27023 434- 586-0699 DATE Rl, R SIGNED: 12114120 17 c 04TAT OF zt 0 REV R I B Luis R. Lomas P.E. FL No.: 62514 2 3/16 13/16" III LIT=` FLANGE FRAME HEAD, cm- 18501 ALUMINUM6063-T5 050'THICK 2 51/16" - FLANGE FRAME SILL CM 18502 ALOMINUM6063-T5.055' THICK 1 314 11 IT, j — LOCK RAIL/STILE cm-1-8563 ------ ALUMINUM 6063- T5 062' THICK GLAZING BEAD RIGhl) PVC.050' THICK 1 7/8" - I T- 2 3/16" L FLANGE FRAME JAMB cm- 18503 ALUMINUM 6063- T5,050'THICK 2 5/16" T 1 2 13/1 E FINLESS FRAME SILL CM 18554 ALUMINUM 6&63-T,'5.055'THICK 1 7/16" 2 S 16 L SASH BOTTOM RAIL cm- 18555 ALUMINUM 6063-T5,050"THICK SASH STILE TNFIW507 ALUMINUM 6063-T5.050"THICK 2 3/16" 1 5/16" J---- FINLESS FRAME HEAD ow-18553 ALUMINUM 6063-T5.050' THICK 2 5/16- 3 314" L ---0 FIN FRAME SJLL cm- 18509 ALUMINUM 6063- TS.055" THICK 11 1/8- F1 — 1 2' J— PAI MEETING RAIL C iVf18-504ALUMINUM 6063-T5.055'THICK 1 1 3/8L- 2 3116" Ir L FINLESS FRAME JAMB cm- las 13 ALUMINUM 6063-T5,050"THICK 2 3/16" 2 5/16" I --- FIN FRAME HEAD cm- 18508 ALUMINUM 6063-75.050'THICK 2 3/5- 2 3/16" L-- q- FIN FRAME JAMB CM 18510 AL. UMINUM6063-TS.050'THICK REVISIONS DESGNtPTWTI MT AITRIWED REVISED AP4CHOR SPACINI, & CHARTS 07/ 1 1/16 R REVISED GtAsl; R'L 5/ 8" - 1/ 8" ANN. - 1/8" ANN. 8" ANN. jj 090 PV8 BY KURARAY MFIAL REINFORCED PUlYI, SPACEP EXTERIOR INTERIOR 1/ 2" BITE SILICONE SEALANT SETTING BLOCK GLAZING DETAIL MI WINDOWS AND DOORS, LLC 650 WEST MARKET STREET GRATZ, PA 17030-0370 SERIES 185 ALUMINUM SINGLE HUNG WINDOW 52" X 72'* NON -IMPACT COMPONENTS DRAWN IWG 1* REv N. G. 08-02549 SCALE NTS I DATE 12/29/14 1 S"VE' 1 1 or 11 L. ROBERTO COMAS P, E. 1432 WOODFORD RD LEWISVILLE, NC 27023 434 M8-0609 SIGNED: 1211412017 0 77 E " 4,9, 'p Si ATE OF 0 o// 0NAL 111111100 Luis R. Lomas P.E. FLN. .: 62514 Florida Buildina Code Online PacTe I of 3 F"On, 7, BCIS Horne 1 Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications F5C Staff i BCIS Site Map Links Search Product Approval jif) USER: Public User AP ""oati-ri Detail 71 x FL # FL15349-R9 Application Type Revision Code Version 2017 Application Status Approved Approved by DBPR. Approvals by DERR shall be reviewed and ratified by the POC and/or the Commission if necessary, Comments Archived Product Manufacturer MI Windows and Doors Address/Phone/Email 650 West Market Street Gratz, PA 17030 717) 365-3300 Ext 2560 bsitlinger@miwd.com Authorized Signature Brent Sitlinger bsitlinger@miwd,com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Windows Subcategory Fixed Compliance Method Certification Mark or Listing Certification Agency American Architectural Manufacturers Association Validated By Steven M. Urich, RE Validation Checklist - Hardcopy Received Referenced Standard and Year (of Standard) 5-tmdmd Year AAMA 506 2011 AAMA/WDMA/CSA 101/LS. 2/A440 2008 Equivalence of Product Standards Certified By Product Approval Method Method 1 Option A Date Submitted 12/31/2017 Date Validated 12/31/2017 Date Pending FBC Approval Date Approved 01/04/2018 https:l',I-wrw-w,.floridabuilding.org/prlpr_app__dtl.aspx?paran-i=wGEVXQ,A-tDqtH8S72qvdW1... 1/3 1/2018 Florida Building Code Online Page 2 of 3 Summary of Products FL # LModel, N.-b., or Name Description 15349.1 1185 PW 73 x 72 Insulated Glass I Limits of Use Certification Agency Certificate Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Quality Assurance Contract Expiration Date Design Pressure: +60/-60 04/03/2018 Other: CW-PG60 Installation Instructions FL152q9 Verified By: Luis R. Lomas, PE 62514 Created by Independent Third Party: Yes Evaluation Reports EU5242—.Rg AE S1'31?4B odf Created by Independent Third Party; Ye 15349.2 1185 PW 159 x 54 Triple CHS Insulated Glass Limits of Use Certification Agency Certificate Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: No 01/24/2021 Design Pressure: +55/-55 Installation Instructions Other: R-PG55 f_1LU42 Rom?_jL_Qa:2ZJ43_0f Verified By: Luis R. Lomas, PE 62514 Created by Independent Third Party: Yes Evaluation Reports EU5 Created by Independent Third Party: Yes 15349.3 185 PW Impact 72 x 72 Insulated Laminated Glass Limits of Use Certification Agency Certificate Approved for use in HVHZ: No EL 1. 5_4 9_P 9 __Q A AP ls4 4 df Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: Yes 06/25/2021 Design Pressure: +55/-55 Installation Instructions Other: FW-LC55, Missile Level D, Wind Zone 3. Glass fL 15 49 consisted of 5/32" tempered exterior - spacer - 5/32" Verified By: Luis R. Lomas, PE 62514 annealed / 0.100 Solutia Saflex HP / 5/32" annealed. Glass Created by Independent Third Party: Yes was bedded in Pecora 896 silicone with 5/8" glass bite. Evaluation Reports FL15_349R9 AE-5 2 d1f Created by Independent Third Party: Yes 15349.4 185 PW impact 159 x 54 Triple CMS Insulated Laminated Glass Limits of Use Certification Agency Certificate Approved for use in HVHZ. No Approved for use outside HVHZ*. Yes Impact Resistant: Yes Quality Assurance Contract Expiration Date Design Pressure: +55/-55 01/24/2021 Other* FW-R55, Missile Level D, Wind Zone 3. Glass Installation Instructions consisted of 1/8" annealed exterior - spacer - 3/32" PLja4_9FL9 IL 6146. df annealed / 0.090 Solutia PV6 / 3/32" annealed. Glass was Verified By: Luis Roberto Lomas 62514 bedded in Pecora 896 silicone with 5/8" glass bite. Created by Independent Third Party: Yes Evaluation Reports fLl-a Created by Independent Third Party: Yes 15349.5 185 PW Impact 96 x 60 Insulated Laminated Glass Limits of Use Certification Agency Certificate Approved for use in HVHZ: No F; Jc-4 R - A AP(- 7' ndf Approved for use. outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: Yes 12/05/2020 Design Pressure: +55/-55 Installation Instructions Other: FW-LC55, Missile Level D, Wind Zone 3. Glass consisted of 5/32" annealed exterior - spacer - 5/32" Verified By: Luis Roberto Lomas 62514 annealed / 0.100 Solutia Saflex HP / 5/32" annealed. Glass Created by Independent Third Party: Yes was bedded in Pecora 896 silicone with 5/8" glass bite. Evaluation Reports EL15249 R9 AE 512 77B Created by Independent Third Party: Yes Back Next 2601 BI— stone Road, jjjit h F' ""'.Q9 atj 4 4 The State of Flonda is an AA/ES0 employer. arjvaq, ,m n jA- h Statement :: agLung emer, https://w-,,,,w.floridabuilding.orc,!'Pr/pr app dtl.aspx?parani=wGEVXQw-tDqtHg57'-IqvdWI... 1/3 :1 1/2018 Florida Buildinc, Code Online Page 3 of 3 Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail tc this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850,487, 139S. 'Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have are. The err ils provided may be used for official communication with the licensee. However email addresses are punks record. It you 00 not wish to supply a personai address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click Product Approval Accepts: M U 09 S a Credit Card Safe littps:llw-w v.floridabuilding.oraIprl,'Pr—,tpp_dtl.aspx9param=wGEVXQ,A,,tDqtHS572qvdWI... 1/3) 1/2018 NOTES: 1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH REQUIREMENTS OF THE FLORIDA BUILDING CODE 2. WOOD FRAMING AND MASONRY OPENING TO BE DESIGNED AND ANCHORED TO PROPERLY TRANSFER ALL LOADS TO STRUCTURE. FRAMING AND MASONRY OPENING IS THE RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. 3, IX BUCK OVER MASONRY/CONCRETE IS OPTIONAL. 4. WHERE SHIM OR BUCK THICKNESS IS LESS THAN 1-1/2" WINDOW UNITS MUST BE ANCHORED THROUGH THE FRAME IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS. ANCHORS SHALL BE SECURELY FASTENED DIRECTLY INTO MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE MATERIAL. 5. WHERE WOOD BUCK THICKNESS IS 1-1/2" OR GREATER, BUCK SHALL BE SECURELY FASTENED TO MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE. WINDOW UNITS MAY BE ANCHORED THROUGH FRAME TO SECURED WOOD BUCK IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS. 6. WHERE 1 X BUCK IS NOT USED DISSIMILAR MATERIALS MUST BE SEPARATED WITH APPROVED COATING OR MEMBRANE. SELECTION OF COATING OR MEMBRANE IS THE RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. 7. BUCKS SHALL EXTEND BEYOND WINDOW INTERIOR FACE SO THAT FULL FRAME SUPPORT IS PROVIDED. B. FOR FIN INSTALLATION SHIM AS NEEDED. FOR FRAME INSTALLATION SHIM AS REQUIRED AT EACH ANCHOR LOCATION WITH LOAD BEARING SHIM. SHIM WHERE SPACE OF 1/16" OR GREATER OCCURS. MAXIMUM ALLOWABLE SHIM STACK TO BE 1/4". 9. SHIMS SHALL BE LOCATED, APPLIED AND MADE FROM MATERIALS AND THICKNESS CAPABLE OF SUSTAINING APPLICABLE LOADS. 10, WIND LOAD DURATION FACTOR Cd=1.6 WAS USED FOR WOOD ANCHOR CALCULATIONS. 11. FRAME MATERIAL: EXTRUDED ALUMINUM 6063—T5. 12. UNITS MUST BE GLAZED PER ASTM E1300-04/09. 13. APPROVED IMPACT PROTECTIVE SYSTEM L5 R£Q_VJ= FOR THIS PRODUCT IN WIND BORNE DEBRIS REGIONS. 14. FOR ANCHORING THROUGH FIN INTO WOOD FRAMING OR 2X BUCK USE #6 WOOD SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. REIASIONS DESCRIPTION DATE I APPROVED REVISED INSTALLATION DETAIIS O6/01f15 R.T. REVISED NAME AND ADDRESS 10/27/16 1 R1. 15.FOR ANCHORING THROUGH FRAME INTO WOOD FRAMING OR 2X BUCK USE #10 WOOD SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. 16. FOR ANCHORING THROUGH FRAME INTO MASONRY/CONCRETE USE 3/16" TAPCONS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE WITH 2 1/2" MINIMUM EDGE DISTANCE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. 17.FOR ANCHORING THROUGH FRAME INTO METAL STRUCTURE USE #10 SMS OR SELF DRILLING SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE 3 THREADS MINIMUM BEYOND STRUCTURE INTERIOR WALL, LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. 18. ALL FASTENERS TO BE CORROSION RESISTANT, 19. INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BELOW: A. WOOD: MINIMUM SPECIFIC GRAVITY OF G=0.42 B. CONCRETE: MINIMUM COMPRESSIVE STRENGTH OF 2,000 PSI. C. MASONRY: HOLLOW/FILLED BLOCK PER ASTM C90 WITH Fm=2,OOOPSI MINIMUM. D. METAL STRUCTURE: STEEL 18GA (.048") FY=33KSI/FU=52KSi OR ALUMINUM 6063—T5 FU=3OKS3 .048" THICK MINIMUM 20. GEOMETRIC SHAPES ARE ALSO APPROVED. APPROVED GEOMETRIC SHAPES DIMENSIONS SHALL NOT EXCEED INSCRIBED DIMENSIONS OF APPROVED RECTANGULAR ASSEMBLY SHOWN IN SHEET 2. MI WINDOWS AND DOORS, I_LC 650 W. MARKET ST. GRATZ, PA 17030 SERIES 185 ALUMINUM FIXED WINDOW 73" X 72" NON —IMPACT NOTES TABLE OF CONTENTS DRAWN; Dwo NO SHEET NO.1 DESCRIPTION J.L. 08-02357 1 1 NOTES SCALE NTS IDATE 09/03/14 1SHEET 1 OF 12 2 = 3 1 ELEVATIONS, CHARTS AND GLAZING DETAILS 4 12 1 INSTALLATION DETAILS L. ROSERTO LOMAS P.E. 1432 WODOFORD RD LEWISVILLE, NC 27023 434-568 0609 ft-913-pe-con, SIGNED: 1111512016 9LIlIL1.1V/ 1 ti,'XGENS;gcP!' T,ATE OF 'mt,J Rcv 'i'nF•'OR10A. Luis R. Lomas P.E. FL No.: 62514 REVISIONS 72 1/2" MAX FRAME WIDTH REV DESCRIPTION DATE APPROVED 6" MAX — 18" MAX O.C. 6" MAX NOTES: A REVISED INSTALLATION DETAILS 06/01/15 R.L. 1, MAXIMUMD.L.O.: 59314'X693/4" 9 REVISED NAME AND ADDRESS 10/27/16 R.L. I CHART #9 18" Number of anchors required (wiihaut rigid filters) MAX O.C. Frame Frame width (in) Heighl 24,00 1 30,00 36,00 42,00 48,00 1 54,00 60,00 66.00 72,60 I it HAS bl HAS Vmb HAS Jamb HAS Pamb HAS Jambl HAS Jamb HAS Jamb HAS Jamb HAS amb 24.00 2 2 2 2Z34 2 3 2 d 2 4 2 d 2 5 2 30,00 2 2 2 2 2 3 2 4 2 4 2 4 2 5 2 71 1/2" 36.00 2 3 2 3 3 3 3 4 3 4 3 5 3 5 3 MAX 42.00 2 3 2 3 3 3 3 4 3 3 5 3 6 3 FRAME 48,00 2 3 2 3 3 3 3 4 3 5 3 6 3 6 3 HEIGHT 54,00 2 J 2 J 4 3 4 4 4 5 4 6 d 7 4 60,00 2 4 2 4 5 3 4 5 5 5 6 5 7 5 66,00 2 92 4 5 3 6 d fi 5 6 6 6 1 6 71.60 2 5 2 5 6 3 5 4 7 5 7 8 7 7 7 REFER TO CHARTS ------SERIES 185 ALUMINUM FIXED WINDOW 1 & #2 EXTERIOR VIEW CHART#2 FOR NOMB£R OF - ANCHORS REQUIRED Number of anchors required (wNh rigid filters) 72 1/2" MAX FRAME WIDTH Fame Frame width fin) 6" MAX — 18" MAX O.C. Height 24.00 30.00 1 36.00 42.00 48.00 1 54,00 0,00 66,00 72.50 6" MAX it") HAS Jamb HAS Jamb HAS P..b HAS Jamb HAS J.mbI HAS P.mb HAS amb HAS lamb HAS amb 24,00 2 2 2 2 3 2 3 2 3 2 4 2 4 2 4 2 5 2 30,00 2 2 2 2 3 2 3 2 3 2 4 2 4 2 4 2 5 2 6" 36,00 2 3 2 3 3 3 3 3 3 3 4 3 4 3 4 3 5 3 342,00 2 3 2 3 3 3 3 3 3 3 4 3 4 3 4 3 5 48,00 2 3 2 3 3 3 3 3 3 3 4 3 4 3 4 3 5 3 54,00 2 4 2 4 3 4 3 4 3 4 4 4 4 4 4 4 5 4 60.00 2 4 2 4 3 4 3 4 3 4 4 4 0 4 4 4 5 4 71 1 /2" 18" 66,00 2 4 2 4 3 4 3 4 3 4 4 4 4 4 4 4 5 4 MAX MAX O.C. 71.50 2 5 2 5 3 5 3 5 3 5 4 5 1 4 5 1 4 5 5 5 FRAME SEE SHEETS 4-7 FOR INSTALLATION DETAILS HEIGHT j REFER TO CHARTS — SERIES 185 ALUMINUM FIXED DESIGNER WINDOW 1 & #2 EXTERIOR VIEW FOR NUMBER OF ANCHORS REQUIRED DESIGN PRESSURE 17ATING IMPACT RATING 60.OPSF NONE MI WINDOWS AND DOORS, LLC 650 W. MARKET ST. GRATZ, PA 17030 SERIES 185 ALUMINUM FIXED WINDOW 73" X 72" NON —IMPACT FLANGE & FINLESS ELEVATION & CHARTS DRAWN; DWG No. J.L. 08-02357 SCALE NTS DATE 09/03/14 5'-2 OF 12 1, HOBc"RTO LOMAS P.E. 1432 WOODFOAD RD LEWISVILLE, NC 27023 434-b88-0604 tttomas 7ricmaspa.cxI, SIGNED, 1111512016 R- L/off 6 61 REV '`''CflRiDA•- Luis R. Lomas P.E. FL NO.; 62514 71 F FF Fit v 1 I L 72 1/2" MAX FRAME WIDTH I 18" MAX O,C. 18" MAX O,C. 1/2" VAX AME GHT 6" MAX REFER TO CHART #3 SERIES 185 ALUMINUM FIXED WINDOW FOR NUMBER OF EXTERIOR VIEW ANCHORS REQUIRED 72 1/2" MAX FRAME WIDTH — 6" MAX — J 18" MAX O.C. — 6„ MAX 00 18" MAX-7O.C—. 1 71 1/2" MAX FRAME 00 HEIGHT I REFER TO CHART #3 FOR NUMBER OF SERIES 185 ALUMINUM FIXED DESIGNER WINDOW ANCHORS REQUIRED EXTERIOR VIEW DESIGN PRESSURE RATING IMPACT RATING 60.OPSF NONE NOTES: 1. MAXIMUM D.L.O,: 69 314'X 68 314" RE14S10NS ' REV DESCRIPTION DATE APPROVED A REVISED INSTALLATION DETAILS 06/01/15 Rl, t3 REVISED NAME AND ADDRESS 10/27/16 R.L. CHART#3 Number of anchors required (fin inslalla(ion) Frame Frame width Iinj Height 24,00 30.00 36,00 1 42.00 1 48,00 54,00 60.00 66,00 1 71.50 m) Md5 lamb HAS amb H&S Jambi HIS J-151 HAS Jamb H&S amb H&S Jamb HAS ainbj HAS amb 14.40 3 3 3 3 3 3 4 3 4 3 4 3 5 3 5 3 6 3 30,00 3 3 3 3 3 3 4 3 4 3 4 3 5 3 5 3 6 3 36,00 3 3 3 3 3 3 4 3 4 3 4 3 5 3 5 3 6 3 42.00 3 4 3 4 3 4 4 4 4 4 4 4 5 4 5 4 6 4 48,00 3 4 3 4 3 4 4 4 4 4 4 4 5 4 5 4 6 4 54,00 3 4 3 4 3 4 4 4 4 4 4 4 5 4 5 4 6 4 60,00 3 5 3 5 3 5 4 5 4 5 4 5 5 5 5 5 6 S 66.00 3 5 3 5 3 5 4 5 4 5 4 5 5 5 5 5 6 5 71.50 3 6 3 6 3 6 4 6 4 6 4 6 5 5 5 6 8 6 SEE SHEET 8 FOR INSTALLATION DETAILS MI WINDOWS AND DOORS, LLG 650 W. MARKET ST. GRATZ, PA 17030 SERIES 185 ALUMINUM FIXED WINDOW 73" X 72" NON —IMPACT FIN ELEVATION & CHART DRAWN: DWG NO, J.L. 08-02357 s uE NTS — 09/03/14 IS-3 OF 12 L. RORERTO LOMAS P_E. 1432 W"FORD RO LEWISVILLE, ,VC 27023 434-638-0609 dkb asLalfriomasPe.c SIGNED: 1111,512016 t i 1Ril lLIo / 7 u, XOEN0 q+P it4. T AT 61 Lk REV 0R14P. JONA I-C Luis R. Lomas P.E. FL No.: 62514 WOOD FRAMING OR 2X BUCK BY OTHERS BACKER ROD APPROVED SEALANT EXTERIOR 112" MIN. EDGE DISTANCE 1 1/4" MIN. F EMBEDMENT T/4" MAX j SHIM SPACE 10 WOOD SCREW 10 WOOD SCREW RICIO FILLLR BACKER ROD APPROVED 1/4*' MAX- SEALANJ SHIM SPACE WOOD FRAMING 1 1/4" MIN. OR 2X BUCK EMBEDMENT BY OTHERS 1/2" MIN, EDGE DISTANCE VERTICAL GROSS SECTION WOOD FRAMING &fi-2TRUCK1,N—SFALLATION 1 1/4" MIN, 1/4" MAX, EMBEDMENT SHIM SPACE EDGE A INTERIOR 10 WOOD SCREW WOOD F R EXTERIOR OR 2X BUCK BACKER ROD BYOTHERS & APPROVED SEALANT JAMB INSTALLATION DETAIL WOOD FRAMING OR 2X BUCK INSTALLATION METAL SIRUCTURE BY OTHERS BACKER ROD APPROVED SEALANT EXTERIOR BACKER ROD APPRO' VED SEALANT META STRUCIUR BY OTHER 3/ 4" MIN EDGE DISTANCE 1/ 4" MAX, j SHIM SPACE IF I10 SMS OR SELF DRILLING SCREW INTERIOR SMS OR DRILLING W FILLER 1/ 4" MAX, SHIM SPACE 3/ 4- MIN EDGE DISTANCE VERTICAL CROSS SECTION METAL STRUCTURE INSTALLATION 1/ 4" MAX. SHIM SPACE 3/ 4" MIN. INTERIOR EDGEDISTANCE10 S S OIR SELF DRILLIG SCREWS METAL. EXTERIOR STRUCTURE BACKER ROD BY OTHERS & APPROVED SEALANT JAMB INSTALLATION DETAIL METAL STRUCTURE INSTALLATION REASIGNS REVISED INSTALLATION DETAILS REVISED IIAME AND ADDRESS 11AIS ANIR011D I R. L. NOTES: 1. INTERIOR AND EXTERIOR FINISHES, 13Y OTHERS, NOT SHOWN FOR CLARITY. 2. PERIMETER AND JOINT SEALANT RY OTHERS TO LIE DESIGNED IN ACCORDANCE WITH ASTM E2112 SIGNED: 1111512016 MI WINDOWS AND LAC MARKETDOORS, 650WST. s g. GRATZ, PA 17030 ENS 0 5 I SERIES 185ALUMINUMFIXEDWINDOW73" X 72" NON -IMPACT 7 XTAT R; FINLESS INSTALLATION DETAILSWITHOUTFILLERSDRAWNNO, REV 08-02357 B P NAL. 11111110\ Luis R. Lomas P,E, FL No.: 62514 GA LE NTS j-'E 09/03/14 --4 OF 12 L. ROBERTOLOMASPE 1432 WOODFORD RD LEWISVILtf-, AAC27023 434-68,9- W9 C 2 1/2" MIN, EDGE: DISTANCE CONCRETE/MASONRY BY OTHERS OPTIONAL IX BUCK 4 1 1/4- MIN. SEE NOTES 3 — 7 EMBEDMENT SHEET I ----T BACKER ROD APPROVED SEALANT EXTERIOR BACKER ROD APPROVED SEALANT OPTIONAL IX DUCK SEE NOTE 3 -- 7 SHEET I CONCRETE/MASONRY BY OTHERS 1 1/4" MIN, EMBEDMENT CONCRETE/MASONRY 1/4" MAX. BY OTHERS SHIM SPACE OPTIONAL IX BUCK SEE NOTES 3 -- 7 SHELF I 3116" TAPCON INTERIOR 3/16" TAPCON 3/16" TAPCON 1/4" MAX. SHIM SPACE 1 1/4" MIN. EMBEDMENT 2 1/2" MIN. EDGE DISTANCE VERTICAL GROSS SECTION INS TALLATIONSTALLATION NOTES: 1. INTERIOR AND EXTERIOR FINISHES, BY OTHERS, NOT SHOWN FOR CLARITY. 2, PERIMETER AND JOINT SEALANT BY OTHERS TO BE DESIGNED )NACCORDANCE WITH ASTME2112 REVISIONS REVISED INSTALLATION DETAILS REVISED NAME ANO ADDRESS 1/ 4" MAX, SHIM SPACE INTERIOR 2 112" MIN, EGE DISTDANCE EXTERIOR BACKER RD[) APPROVE D SEALANT JAMB INSTALLATION DETAIL CONCRETEIMASONRY INSTALLATION) D! Tf I APPROVED R. E. SIGNED: 1111512016 MI WINDOWS AND DOORS, LlC L 650 W. MARKET ST. GRATZ, 0 NsF PA17030SERIES 185 ALUMINUM FIXED WINDOW 0 51 73" X 72" NON —IMPACT FINLESS INSTALLATION DETAILS WITHUT FILLERS TATE OF DRAWN REV 4ORk 08j- 0t2357 8 SJALf. DAIE0OF 12 NTS //5 IL. ROBERTO LOWSPE Luis R. Lomas P.E. 1432 WOODFORD RD LEW)SVILI E, NC 27023 FL No.: 62514 WOOD FRAMING DR 2X BUCK BY OTHERS BACKER ROD APPROVED SEALANT EXTERIOR BACKER ROD APPROVED SEALANT WOOD FRAMING OR 2X BUCK BY OTHERS 112" MIL'T EDGE DISTANCE 1 1/4" MIN F EMBEDMENT SHIM SPACE RIGID FILLER 10 WOOD SCREW INTERIOR 10 WOOD SCREW RIGID FILLER 1/4" MAX, SHIM SPACE MIN EMBEDMENT 1/2" MIN, EDGE DISTANCE VERTICAL CROSS SECTION vvO6D_FRAMING OR2_X_ BUCKINSTALLATION 1 1/4" MIN, 1/4' MAX, EMBEDMENT SHIM SPACE RIGID FILLER 1 / 2" MILT EDGE DISTANCE INTERIOR I 1 METAL STRUCTURE BY OTHERS BACKER ROD APPROVED SEALANT EXTERIOR BACKER ROD APPROVED SEALANT META STRUCTUR BY OTHER 3/ 4- MIN EDGE DISTANCE 1/ 4" MAX, SHIM SPACE RIGIO FILLER 10 SMS OR SELF DRILLING SCREW INTERIOR SMS OR DRILLING W FILLER 1/ 4" MAX, SHIM SPACE 3/ 4" MIN EDGE DISTANCE VERTICAL CROSS SECTION METAL STRUCTURE INSTALLATION 1/ 4" MAX, SHIM SPACE RIGID FILLER 3/ 4- MIN - EDGE DISTANCE INTERIOR 10 WOOD #10 SMS OR SCREW IV SELF DRILLING SCREWS WOOD F P l 7 EXTERIOR METAL ___.-_—,_.— BY EXTERIOR OR 2X HUCK 71 ELL OTHERS BACKER ROD STRUCTURE BACKER ROD APPROVED BY OTHERS & APPROVED SEALANT SEALANT JAMB INSTALLATION DETAIL JAMB INSTALLATION DETAIL wc, 66 _FRAwwc, OR 2X -at—) FK 7PiS_T 4L L A TION METAL STRUCTURE INSTALLATION GATE APPROV11) ROVISED INSTALLATION VEIAItS PEViSff) NAME AND ADDRESS NOTES, I. INTERIOR AND FXTFRJOR FINISHES, BY OTHERS, NOT SHOWN FOR CLARITY. 2, PERIMETER AND JOINT SFAI,ANT BY OTHERS TO BE DESIGNED IN ACCORDANCE WITH AS TM E2112 SIGNED: 1111512016 MI WINDOWS AND DOORS, LLC 650 W. MARKET ST, 0 GRATZ, PA 17030 SERIES 185 ALUMINUM FIXED WINDOW 73" X 72" NON --IMPACT FINLESS INSTALLATION DETAILS WITH RIGID FILLERS 0 F DWr NO, JL. 08-02357 B Luis R, Lomas P,E. ISCALE NTSHATE09/03/14 ISHE"6 OF 12 L. ROBERTOLOMASPE 1432 WOODFORD RD LEWISMLE, NC 27023 FL No.: 62514 434CSS.0609 REVISIONS REV DESCRIPTION 1.1E Alll'.,ylv 2 1/2" MIN, A RFVJSED INSTALLATION DETAILS 15;]R1T, EDGE DISTANCE B REVISED NAME AND ADDRESS R.L. CONCRETE/ MASONRY 9Y OTHERS 1 1/4" MIN, OPTIONAL IX BUCK 1 1/4" MIN. EMBEDMENT SEE NOTES 3 -- 7 EMBEDMENT SHEET I CONCRETE/ MASONRY BACKER ROE) 1 _/4 " —MAX—T BY OTHERS 1/4" MAX. APPROVED C SHIM SPACE SHIM SPACE SEALANT J OPTIONAL iX BUCK RIGID FiLLFR SEE NOTES 3 __ 7 RIGID FILLER SHEETI3/ 16" I`APCON EXTERIOR INTERIOR 3/16- TAPCON INTERIOR BACKER ROD 3/ 16" TAPCON APPP. ovib RIGID FILLER SEALANT 1/ 4" MAX, 2 1/2" OPTIONAL IX PUCK SEE NOTE 3 _77 SHIM SPACE MIN, SHEET I EDGE ° DISTANCE EXTERIOR CONCRETE/ MASONRY PACKER ROD N APPROVED 13Y OTHERS /4" MIN, SEALANT EM19JEDMENTJAMB INSTALLATION DETAIL CONCRE TEIMASONRY INS TALLA TION 2 1/2" MIN, GE D EDGEDISTANCEVERTICAL GROSS SECTION CONCRETE/ MASONRY INSTALLATION SIGNED: 1111,1512016 MI WIND O50WS . MAANDRKETDOORS, LLC01illhjr/j/ S 6WST. NOTES: GRATZ, PA 17030 1. INTERIOR AND EXTERIOR FINISHES, BYOTHERS, SERIES 185 ALUMINUM FIXED WINDOW 0 5 NOT SHOWN FOR CLARITY. 73" X 72" NON —IMPACT FINLESS INSTALLATION DETAILS WITH RIGID FILLERS 2, PERIMETER ANDJOINT SFALANTBY OTHERST013ETATOFDESIGNEDINACCORDANCE WI fil ASTM E2112 0 R I C.L. - E 085072357 NTS / 11,1111119//TOF 12 0, L. ROBERTOLOMASPELuisR. Lomas P.E. 1432 WOODFORD RD LEWISVILLE, NC 27023 434-CS8 0609 FL No": 62514 WOOD FRAMING OR 2X FR)(,K By ONIERS BACKER ROD & APPROVED SEALANT HFHIND FLANGE 112" MIN. EDGE DISTANCE 1 114" MIN. EMBEDMENT 1/4" MAX. SHIM SPACE RIO WOOD SCREW EXTERIOR INTERIOR 10 WOOD SCREW RIGID FILLER BACKER ROD A APPROVED SEALANT 1/4" MAX. HUHIND RANGE SHIM SPACE WOOD FRAMING 1 1/4" MIN. OR 2; RUCK EMBEDMENT BY OTHERS 112" MIN EDGE DISTANCE VERTICAL CROSS SECTION WOOD FRAMING OR 2X BUCK INSTALLATION 1 1/4" MIN. 1/4" MAX. EMBEDMENT SHIM SPACE 112 MLN, EDGE DISTANCE INTERIOR 10 WOOD FRAMING OR 2X BUCK EXTERIOR BY OTHERS BACKER ROD & APPROVED SEALANT BEHIND FLANGE JAMB INSTALLATION DETAIL 14006FRAPX JNO KINS7ALLA7ION5ii)FIM METAL STRUCTURE BY OTHERS BACKER ROD & APPROVED SEALANT BEHIND FLANGE 1/4" MAX, SHIM SPACE 10 SMS OR ELF DRILLING CREW EXTERIOR INTERIOR 10 SMS OR SELF DRILLING Iz SCREW BACKER ROD & RIGID FILLER APPROVED SEALANT BEHIND FLANGE 1/4- MAX, I SHIM SPACE STRUCTURE BY OTHERS 3/4- MIN EDGE DISTANCE VERTICAL CROSS SECTION METAL ifRTI—CTV E 1NS-0-ALL—A NON 1/4" MAX, SHIM SPACE 3/4" WE!. INTERIOR EDGE DISTANCE 10 SMS OR SELF DRILLING SCREWS METAL EXTERIOR STRUCTURE BY OTHERS BACKER ROD & APPROVE[) SEALANT BEHIND FLANGE JAMB INSTALLATION DETAIL METAL STRUCTURE INSTALLATION ON REVISED ;NSTALLATION DE fA4-S ViSEV NAME AND ADDRESS 06/01/15 RL 3 012 711 F f>t NOTES' I INTERIOR AND EXTERIOR FINISHES, BY OTHERS, NOT SHOWN FOR CLARITY. 2 PERIMETER AND JOINT SEALANT BY OTHERS TO BE DESIGNED IN ACCORDANCE WITH ASTAA E2112 SIGNED: 1111512016 MI WINDOWS AND DOORS, LLC 650 W. MARKET ST. GRATZ, PA 17030 SERIES 185 ALUMINUM FIXED WINDOW 73" X 72" NON —IMPACT 777FLANGEINSTALLATIONDETAILSWITHOUTFILLERS T OF o. PAWN 08-02357 REV B DAIE I SKETSCLfNTS09/3/ 014 8 OF 12 L. POSER FO tOMAS P E. 1432 WOODFORD RD LEWISVILLE, PJC 27023 Luis R. Lomas P.E. FL No.: 62514 2 1/2" MIN. EDGE DISTANCE CONCRETE/MASONRY BY OTHERS o 1 1/4" MIN, OPTIONAL IX BUCK - - - - - ° EMBEDMENT SEE NOTES 3 - 7 SHEET 1 BACKER ROD & APPROVED SEALANT SHIM SPACE BEHIND FLANGE EXTERIOR BACKER ROD & - A.PPROVED SEALANT BEHIND FLANGE OPTIONAL 1 X BUCK - SEE NOTE 3 - 7 SHEET 1 CONCRETE/MASONRY BY OTHERS 3/16" TAPCON INTERIOR 3/16" TAPCON 1/4" MAX. SHIM SPACE e • ° 4 a 2 1/2" PAIN. EDGE DISTANCE VERTICAL CROSS SECTION CONCRETEIMASONRY INSTALLATION 1 1/4" PAIN. EMBEDMENT CONCRETE/MASONRY BY OTHERS OPTIONAL 1 X BUCK SEE NOTES 3 - 7 a SHEET 1 3/16" TAPCON 2 1/2" < MIN. a EDGE REVISONS REV DESCRIPTION DATE APPROVED A REVISED INSTALLATION DETAILS 06/01/15 R.L. B REVISED NAME AND ADDRESS 10/27/16 R. L. 1/4" MAX. SHIM SPACE INTERIOR DISTANCE EXTERIOR BACKER ROD & APPROVED SEALANT 1 1/4" MIN. BEHIND FLAI4GE EMBEDMENT JAMB INSTALLATION DETAIL CONCAETEIMASONRY INSTALLATION SIGNED: 1111512016 MI WINDOWSW. ANDK'50ORS, LLC o GRATZ, PA 17030 SERIES 185 ALUMINUM FIXED WINDOWNOTES: l0 51 *= 1. INTERIOR AND EXTERIOR FINISHES, BY OTHERS, 73" X 72" NON-IMPACT,qNOTSHOWNFOACtARITYFLANGEINSTALLATIONDETAILSWITHOUTFILLERSa , STAT OF cL 2. PERIMETER AND JOINT SEALANT BY OTI4FRS TO BE E2112 0. tL SjL N: Dwc NO. 8DESIGNEDINACCORDANCEWITHASTM 0 R OS-02357 X77I%J l'ASCALENTSDATE09/03/14 SHEET 9 OF 12 111'•, L. ROBERTO LOMAS P E. Luis R. Lomas P.E. 1432 WOODFORD RD LEWISVILLE, NC 27023 FL NO.: 62514 434-688-0609 dtomaa@idpmaspe. com 1/2" MIN. EDGE DISTANCE WOOD FRAMING -- / J 1/4" MIN. OR 2X BUCK % EMBEDMENT 0Y OTHERS 1/4" t,1AX. BACKER ROD & SHIM SPACE APPROVED SEALANT BEHIND FLANGE RIGID FILLER 1S 10 WOOD SCREW METAL STRUCTURE BY OTHERS BACKER ROD & APPROVED SEALANT BEHIND FLANGE 1/4" MAX. SHIM SPACE CID FILLER 10 SMS OR ELF DRILLING REW EXTERIOR EXTERIOR INTERIOR INTERIOR 10 SMS OR 10 WOOD SCREW SELF SCREW RILLING BACKER ROD & RIGID FILLER BACKER ROD & RIGID FILLER APPROVED SEALANT 1/4" MAX. APPROVED SEALANT BEHIND FLANGE SHIM SPACEJ' BEHIND FLANGE - 1/4" MAX. SPACEjISHIM WOOD FRAMING OR 2X BUCK 1 1/4" MIN. METAL STRUCTURE BY OTHERS EMBEDMENT BY OTHERS 3/4" MIN 1 J2 MIN EDGE DISTANCE 1- EDGE DISTANCE VERTICAL CROSS SECTION_ VERTICAL CROSS SECTION METAL STRUCTURE INSTALLATION WOOD FRAMING OR 2X BUCK INSTALLATION RE'4SiONS :. REV DESCRIPTION On7E APPROUEO A REVISED INSTALLATION DETAILS D6f07 f 15 R.L. B REVISED NAME AND ADDRESS 10/27/16 I R.L.. NOTES: 1. INTERIOR AND EXTERIOR FINISHES, BY OTHERS, NOT SHOWN FOR CLARITY. 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE DESIGNED IN ACCORDANCE WITH ASTM E2112 1/4" MAX. 1 1/4" MIN. 1f4" MAX. SHIM SPACE EMBEDMENT SHIM SPACE RIGID FILLER i — RIGID FILLER 1/2" MIN. 3/4" MIN. DISTANCE INTERIOR SIGNED.' 1111512016EDGEDISTANCEEDGE INTERIOR MI WINDOWS AND DOORS, LLC ST. 11 /i650W. MARKET GRATZ, PA 17030 J\ . • ti10WOOD10SMSOR SCREW SELF DRILLING SERIES 185 ALUMINUM FIXED WINDOW SCREWS 73" X 72" NON -IMPACT WOOD FRAMING EXTERIOR METAL EXTERIOR FLANGEIr— INSTALLATION DETAILS WITH RIGID FILLERS fll ,srrtt= p , STATE OF cN pry. OR 2X BUCK BY OTHERS BACKER ROD & STRUCTURE BY OTHERS BACKER ROD & oRnwN: owc NO. REv i ZORin;• '.. S' • - • . • - G S/ONA 11 VFIANCSEALANTAPPROVED SEALANT OS _ 2357 B BEHIND BEHIND NGEGALE NTS DATE 09/03 14 S eE 10 OF 12 JAMB_ INSTALLATION DETAIL JAMB INSTALLATION DETAIL L. ROBERTO LOMAS P. Luis IsR. Lomas P.E. WOOD FRAMING OR 2XBUCK INSTALLATION METAL STRUCTURE INSTALLATION 1432 WOODFORD RD LEWISVILLE, NO 27023 FL NO.: 62514 434- 669-0609 AfomasOa lRomaspe corn 2 1,12" MIN. EDGE DISTANCE CONCRETE/MASONRY BY OTHERS 4. 14 1 1/4" MIN, OPTJOI` -JAL IX BUCK EMBEDMENT SEE NOTES 3 7 SHEET 1 BACKER ROD & APPROVED SEALANT BEHIND FLANGE EXTERIOR BACKER ROD & APPROVED SEALANT BEHIND FLANGE OPTIONAL IX BUCK SEE NOTE 3 - 7 SHEET I CONCPF FF/fAASONPY BY OTHERS 1/4" MAX. SHIM SPACE RIGID FILLER 3/16" TAPCON INTERIOR 3/16" TAPCON RIGID FILLER 1/4" MAX. SHIM SPACE ATE APPRMEO REVISED INSTALLATION DETAILS 06/01/15 R L REV6ED NAME AND ADDRESS 10127116 R.L. 1 1/4" MIN, EMBEDMENT F, CONCRETE/MASONRY BY OTHER, 1/4" MAX. SHIM SPACE OPTIONAL IX BUCK SEE NOTES 3 - 7 SHFFT I RIGID FILLER 3/16- TAPCON INTERIOR 1 1/4" MIN. EMBEDMENT 2 112" MIN. EDGE DISTANCE VERTICAL CROSS SECTION CONCRETE/MASONRY -INSTALLATION 2 1/2- MIN, EDGE DISTANCE EXTERIOR BACKER ROD & APPROVED SEALANT BEHIND FLATICE JAMB INSTALLATION DETAIL CONCRETE/MASONRY INSTALLATION 011GINED: 111151,2016 MI WINDOWS AND DOORS, LLC NOTES, 1. INTERIORAND EXTERIOR FINISHES, BYOTHERS, 650 W. MARKET ST. L 0 NOT SHOWN FOR CLAPI I Y, GRATZ, FA 17030 SERIES 185 ALUMINUM FIXED WINDOW2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE DESIGNED INACCORDANCE WITHASTM E2112 73" X 72" NON -IMPACT 4.T';AfFLANGEINSTALLATIONDETAILSWITHRIGIDFILLERS5-lpll OF 0 RDRAWN: NO IV L. 08-02357 N ALSCE DA" FNTSI09/03/14 "" 11 OF 12 11 1— L. R0.Rlll 1011"Es P. F. Luis R. Lomas P.E. 7432 woODFonD RD Lcwtswu E, Ne 27N-j FL IN 62514 4346880609d;-,ekA-,V- REV DESCRIPTON DATE APPROVED A REVISED INSIALIATION DETAILS 06/01/15 P.ii. APPROVTO B RC,11SED NAME AND ADDRESS 10127116 R 1" SEALANT----- BEHIHOLNJ 1 1/4- MIN. EMBEDMENT W6 OOD WOOD SC FRAMINGSCREW BY OTHERS 1/4" MAX. SHIM SPACE WOOD FRA 1/4" MAX 3/8 11 MIN BY OTHERS SHIM SPACE EDGE DISTANCE j 6 WOOD INTERIOR SCREW INTERIOR I- - EXTERIOR 1 1/4- MIN. NOTES: 1/4" MAX I INTERIOR AND EXTERIOR FINISHES, 8YOTHERS. SHIM SPACE APPROVED NOT SHOWN FOR CLARITY. SEALANT 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE BEHIND FIN DESIGNED IN ACCORDANCE WITH ASTM E2112 3/8" MIN EXTERIOR 3/8" MIN EDCE DISTANCE EDGE DISTANCE JAMB INSTALLATION DETAIL 6 WOOD-- WOOD SCREW FRAMING WOOD FRAMING OR 2X BOOK INSiALLA [ICA APPROVED — 1/4" MIN. BY OTHERS SEALANT EMBEDMENT BEHIND FIN VERTICAL CROSS SECTION WOOD FRAMING OR 2X Bt ICK INSTALLATION MI WINDOWS AND DOORS, LLC 650 W. MARKET ST. GRATZ, PA 17030 SERIES 185 ALUMINUM FIXED WINDOW 73" X 72" NON —IMPACT FIN INSTALLATION DETAILS DRAWN: wr 0, J, L, I 08-02357 1 SCALE NTS I —E 09/03,14 L"11112 OF 12 1. ROBEFOO tOMAS PE WOODFORD RD LEWISVII I E, NC 27023 SIGNED: 1111512016 R, L o iT A _0F tOR10t- tr1 1810NAI, _- Ltjjs R. Lomas P.E. FL No.: 62514 Florida Building Code Online Page I of 3Z: R14 lit 5CIS Home Log in Use( Registration Hot Topics Submit Surcharge Stats & ;acls Publications FBC Staff t 5c's Site Mao Links Search rProduct Approval ( A USER: Public Use, 11—o > Application Detail 7, FL# FL15353-R3 Application Type Revision Code Version 2017 Application Status Approved Comments Archived Product Manufacturer MI Windows and Doors Address/Phone/Email 650 West Market Street Gratz, PA 17030 717) 365-3300 Ext 2560 bsitlinger@miwd.com Authorized Signature Brent Sitlinger bsitiinger@m'wd.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Windows Subcategory Mullions Compliance Method Evaluation Report from a Florida Registered', Architect or a Licensed Florida Professional Engineer 7-- Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed Luis R Lomas, RE the Evaluation Report Florida License PE-62514 Quality Assurance Entity National Accreditation and Management Institute Quality Assurance Contract Expiration Date 12/31/2018 Validated By Steven M. Urich, RE Validation Checklist - Hardcopy Received Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Sections from the Code Product Approval Method ELLI—iUL-R7 L=f 5Aandard AAMA 450 Method I Option D Year 2010 https:,/,,',A,-",rw.floridabuilding.or,,/P r/pr app dtl.aspx?param=wGEVXQxvtDqtl-18571 qvdv 71S... 2111/2018 Z:, Florida Building Code OnlineZ:1 Pale 2 of 3 Date Submitted 10/16/2017 Date Validated 10/23/2017 Date Pending FBC Approval 10/26/2017 Date Approved 12/12/2017 Summary of Products FL # Model, Number or Name Description 5764 Horizontal Aluminum Mullion Limits of Use Installation Instructions Approved for use in HVHZ: No ELL5121 P 11- 144 f Approved for use outside HVHZ: Yes Verified By: Luis R Lomas, PE PE-62514 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Max single window size: 52-1/8" x 84". Max mullion FL15353 R3 AE 51221,,?Bj2 f span: 104-1/4". Created by Independent Third Party: Yes 15353.2 5764 Vertical Aluminum Mullion Limits of Use Installation Instructions Approved for use in HVHZ: No 1`1-153;3 E3 TI 14-, k f Approved for use outside HVHZ: Yes Verified By: Luis R Lomas, PE PE-62514 Impact Resistant* Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Max single window size: 52-1/8" x 84". Max mullion FL P span: 83" Created by Independent Third Party: Yes 15353.3 5765 Horizontal Aluminum Mullion Limits of Use Installation Instructions Approved for use in HVHZ: No f]L 1 3- R i I Q_4 1) d f Approved for use outside HVHZ: Yes Verified By: Luis R Lomas, PE PE-62514 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Max single window size: 52-1/8" x 84". Max mullion fL!.,—,,53 R span: 156-3/8" Created by Independent Third Party: Yes 15353.4 15765 Vertical Aluminum Mullion Limits of Use Installation Instructions Approved for use in HVHZ: No n3EL4 a_ _qf Approved for use outside HVHZ: Yes Verified By: Luis R Lomas, PE PE-62514 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Max single window size: 52-1/8" x 84". Max mullion F span: 83". Created by Independent Third Party: Yes 15353. 5 CM-18514 Vertical Aluminum Mullion Limits of Use Installation Instructions Approved for use in HVHZ: No FL15353 R3 11 aL:, 4R f Approved for use outside HVHZ: Yes Verified By: Luis R Lomas, PE PE-62514 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Max single window size: 52-1/8" x 84". Max mullion fL15353 R3 AE51216(-B. df length - 83". Created by Independent Third Party: Yes 15353. 6 CM-18520 Horizontal Aluminum Mullion Limits of Use Installation Instructions Approved for use in HVHZ*. No fll" I 1- U 4D-5-p-dj Approved for use outside HVHZ: Yes Verified By: Luis R Lomas, PE PE-62514 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Max single window size - 52-1/8" x 84". Max mullion PlL! 5a53 R3 AE 21ZL7 span - 156-3/8" Created by Independent Third Party: Yes 1 15353.7 1 CM-18523 I Horizontal Aluminum Mullion I Limits of Use Installation Instructions Approved for use in HVHZ: No FL15353 R3 11 0 5 L'45Zt .Of Approved for use outside HVHZ: Yes Verified By: Luis R Lomas, PE PE-62514 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure. N/A Evaluation Reports Other: Max single window size - 52-1/8" x 84". Max mullion span - 104-1/4". Created by independent Third Party: Yes 15353. 8 CM- 1853 1 Vertical Aluminum Mullion Limits of Use Installation Instructions Approved for use in HVHZ: No FL15353 R3 II 08-014-436,p-jf Approved for use outside HVHZ: Yes Verified By: Luis R Lomas, PE PE-62514 https: I'I,w,w-w,.floridabuilding.org,,'pr,lpr_app_dtl.aspx?parani=wGEVXQ,\N,-tDqtH8572qvdWIS... 2/1/2018 Florida Building Code Online Page 3 of 3 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Max single window size: 52-1/8" x 84". Max mullion _AF_51 ZQ67tp, span - 83" Created by Independent Third Party: Yes 15353.9 _JCM-18532 I Horizontal Aluminum Mullion Limits of Use Installation Instructions Approved for use in HVHZ. No LL3_53R3 11 Approved for use outside HVHZ: Yes 08014535_ pdF Verified By: Luis R Lomas, PE PE-62514 Impact Resistant. Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Max single window size - 52-1/8" x 84". Max mullion fj!_5 52 R3 f span - 156-3/8" Created by Independent Third Party: Yes 15353. 10 CM-18533 Vertical Aluminum Mullion Limits of Use Installation Instructions Approved for use in HVHZ: No FL15°S3 R3 I! q, 44B, Approved for use outside HVHZ: Yes Verified By: Luis R Lomas, PE PE-62514 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Max single window size: 52-1/8" x 84". Max mullion R3 _Af_ q_LjQ span: 83" Created by Independent Third Party: Yes 15353. 11 CM- 18534 Horizontal Aluminum Mullion Limits of Use Installation Instructions Approved for use in HVHZ: No FL15353 R3 II 08-0145,JB.=f Approved for use outside HVHZ: Yes Verified By: Luis R Lomas, PE PE-62514 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other* Max single window size: 52-1/8" x 84". Max mullion FL15M 51112IrL p p ff span: 156-3/8". Created by Independent Third Party: Yes F- 771 Fl`i--_Xt QntAa_ V5 :: 2601 New Stone. Road jajj?has F` Qp The State of Florida is an WEED employer, copyright 2001-2011 SLajt_qLFlqnjL, :: av I , mi" :: FCCes tbillty Statement c Refund Statement Under Florida law, email addresses are public record,. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 8$0,487,1395. `Pursuant to Section 4SS. 275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address it they have one. The emars provided may be used for official communication with the licensee. However email addresses are public record. If you co not wish to supply a personal address, please provide the Department with an email address which can be made available to the duolic. To determine if you are a licensee under Chapter 455, F.S,, please click Lgrg_. Product Approval Accepts: M 9: 1 tl E M creda" Card Safe https:/'/,' NN" A'W.floridabuilding.oro.,"Pr,,,'Pr app -NrGEVXQ A-tDqtH857"-qvd,A,'IS... 2"'T"21018 t.- Z — _dtl.aspx? param= NOTES: I ) T14L PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH REQUIREMENTS OF THE FLORIDA BUILDING CODE. 2) WOOD FRAMING TO BE DESIGNED AND ANCHORED TO PROPERLY TRANSFER ALL LOADS TO SrRUCTURE. FRAMING IS THE RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. 3) ALLOWABLE STRESS INCREASE OF 113 WAS NOT USED IN THE DESIGN OF THE PRODUCT SHOWN HEREIN. WIND LOAD DURATION FACTOR Cd=1.6 WAS USED FOR WOOD ANCHOR CALCULATIONS. 4) APPROVED IMPACT PROTECTIVE SYSTEM ls_NOT _R_QULRED FOR THIS PRODUCT IN WIND BORNE DEBRIS REGIONS UP TO WIND ZONE 3. 5 ) DESIGN PRESSURE AND INSTALLATION DETAILS SHOWN IN THIS DOCUMENT APPLY ONLY TO MULLION. WINDOWS MUST BE APPROVED UNDER SEPARATE APPROVAL. 1 6) SINGLE WINDOWS TO BE MULLED ARE NOT LIMITED TO THOSE SHOWN IN THIS DRAWING. WINDOWS MOST BE MANUFACTURED BY MI WINDOWS AND DOORS, INC, 7) DESIGN PRESSURE Or MULLED UNIT SHALL BE CONTROLLED BY THE LESSER DESIGN PRESSURE OF THE MULLION OR THE INDIVIDUAL WINDOW OR DOOR uNir. 8) UNITS MAY BE MULLED TOGETHER INDEFINITELY AS LONG AS SINGLE UNIT WIDTH AND HEIGHT ARE NOT EXCEEDED AND MULLION IS ANCHORED AS SHOWN HEREIN. 9) MULLION VERTICAL INSTALLATION IS SHOWN, MULLION MAY BE USED IN HORIZONTAL APPLICATIONS AS LONG AS DIMENSIONS INDICATED HEREIN ARE NOT EXCEEDED AND MULLION 15 ANCHORED ACCORDING TO THIS DOCUMENT. DESIGN PRESSURE TABLE INSTRUCTIONS: 1) DEFINE REQUIRED DESIGN LOAD PER FLORIDA BUILDING, CODE CHAPTER 16. 2) DETERMINE IRIBUTARY WIDTH AND MULLION SPAN BASED ON PRODUCT TO BE INSTALLED. SEE FORMULA FOR TRIBUTARY WIDTH. 3) LOCATE. MULLION SPAN (UNIT HEIGHT) AND TRIBUTARY WIDTH. AT THE INTERSECTION OF ROW AND COLUMN CONTAINING THE MULLION SPAN ANO TRIBUTARY WIDTH RESPECTIVELY 15 THE MULLION RATING FOR PRODUCT IN STEP 2. MULLION RATING MUST BE EQUAL OR GREATER THAN REQUIRED DESIGN PRESSURE OBTAINED IN STEP 1. TARY WIDTH = WI -- I W21---- 111111_ 2 DESCRIPTION DATE REVISED INSTALLATION DETAILS 06/10/15 REVISED ANCHORING NOTES & (NSIL OET, 06/07/17 ANCHORING NOTES: 1) FOR ANCHORING INTO WOOD FRAMING OR 2X BUCK USE #10 WOOD SCREW WITH SUFFICIENT LENGTH TO ACHIEVE A 1 3/8" MINIMUM EMBEDMENT. LOCATE ANCHORS AS SHOWN IN INSTALLATION DETAILS S14EET 3. 2) FOR ANCHORING INTO CONCRETE USE 1/4" ELCO ULTRCOLI TAPCON WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT WITH I" MINIMUM EDGE DISTANCE. LOCATE ANCHORS AS SHOWN IN INSTALLATION DETAILS SHEET 3. 3) FOR ANCHORING INTO METAL USE #10 SMS OR SELF DRILLING SCREW WITH SUFFICIENT LENGTH TO ACHIEVE 3 THREADS MINIMUM BEYOND STRUCTURE INTERIOR WALL, LOCATE ANCHORS AS SHOWN IN INSTALLATION DETAILS SHEET 3, 4) ALL FASTENERS TO BE CORROSION RESISTANT. 5) INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS, AND ANCHORS SHALE NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BELOW: A, WOOD - MINIMUM SPECIFIC GRAVITY OF G=0,42 F3, CONCRETE MINIMUM COMPRESSIVE STRENGTH OF 3,200 PSI. C. MASONRY STRENGTH CONFORMANCE TO ASTM C-90, GRADE N, TYPE I (OR GREATER). D. METAL STRUCTURE -STEEL 18CA (.048") FY=33KSI/FU=52KSI OR ALUMINUM 6063-45 FU=3OKSI .062" THICK MINIMUM. 6) FOR ATTACHING WINDOW UNITS TO MULLION USE #10 SELF TAPPING SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE A MINIMUM EMBEDMENT OF THREE THREADS PAST THE MULLION WALL. LOCATE SCREWS 6" FROM EACH MULLION END AND 12" MAX. O.C. 1HEREAFTCR, STAGGER SCREWS AT EACH WINDOW. TABLE OF CONTENTS SHEET NO, DESCRIPTION I NOTES 2 CONFIGURATIONS AND OR CHART 3 INSTALLATION DETAILS 4 COMPONENTS MI WINDOWS AND DOORS, LLC 650 WEST MARKET STREET GRATZ, PA 17030-0370 5764 - VERTICAL MULLION 83" MULLION SPAN GENERAL NOTES DRAWN V1, 1 08-01439 SCALE NTS I GATE 01/11/12 1 '-IT I OF 4 L ROBERTO COMAS P.E. f432 W(X)DrORD RD LEWtSWLLE, NC 27023 434-6880609 rlIctwsc&(el-a5p&corn APPROVED Rl. R.L. SIGNED: 1011312017 0iIIlIRLIll(j//// 0 5 OFTATOF O. ON At 1"Ill(ItI0 Luis R. Lomas P.E. FL No.: 62514 REVISKiNs 107 3/8" 107 3/8- 107 3/8" REV DESCWPTKI. p COMBINED WIDTH COMBINED WIDTH COMBINED WIDTH [_ 5AREVISEDNSTAtIATIONDETAILS06/10/1 R, L, WI W2 WI W I REVISED ANCHGRiNG NOTES & (NSTL JET_ 06/07/17 RA, 83" 83" 83" FRAME FRAME WINDOW FRAME 4DOW INDOW HEIGHT WINDOW WINDOW HEIGHT WINDOW HEIGHT ------- ---------- IAM UON (MULLION (MULLION SPAN) SPAR) Ld [j/[L Lill 107 3/8" COMBINED WIDTH I-_-__ W I W2 F_ __ WINDOW f RAW N tH(AGII IT WI DO WINDO] MALL SPAN) WI W2 107 3/8- L-7COMBINED WIDTH Desi rr pressure ratincil(pso Mullion an (in) Tributary width (in) 18E13 25.50 36.00 42.00 48.00 52-13 120.0 120,0 120,0 120.0 120,0 1200 37.38F49.63 1200 0 120,0 120,0 120.0 120.0 1200 9& 3F33, 81,2 76,9 75.2 75A 6 2-0-0 7IT _0 52 2 79 7 35,9 33A 32.3 6!E6 3 59,6 4 7 310 29,6 27A 263 72,W_f44,9 327 24.4 21.8 19.9 19.0 1 84.00 281 1 203 i - I - 7_1 LARGE AND SMALL MISSILE IMPACT, LEVEL D, WIND ZONE 3 DIMENSIONS IN CHART ARE FRAME DIMENSIONS AND 00 NOT INCLUDE FLANGE. Fi 107 3/I COMBINED WIDTH W2 83" WINDOW FRAME HFIGHT MULLION SPAN) WI W2 107 3/f3 COMOINEO WIDTH F_ 107 3/11" COMBINED WIDTH WI W2 83" WINDOW FRAME HEIGHT WIN W y WINDOW MULLION SPAN) W I W2 107 3/8- _ COMBINED WIDT14 APPROVED CONFIGURATIONS MULTIPLE UNITS MAYBE MULLED TOGETHER AS LONG AS COMBINED WIDTH DOES NOT- EXCEED f07316'ASSHOWN HEREIN. Design pressure rating (pso with rebar Mullion span ( in) Tributary width (in) 18. 13 25,50 48.00 52.13 25, 00 120.0 Q0,0 IL20._ L2.00 120, 0 120,0 120,0 120,0 37. 38 120,0 120.0 120,0 120.0 120,0 120,0 49. 63 1200 F60,103 9& 3 81,2 76,9 752 75.1 62. 00 95,2 70,0 513 48A 44.8 43.4 65. 63 80,0 W686 442 39.7 36,7 35,3 72. 00 419 32.8 29,2 26.7 25,5 84. 00 f 37,7 27.3 20.4 I7.7 160 15,1 LARGE AND SMALL MISSILE IMPACT, LEVEL 0, WIND ZONE 3 DIMENSIONS IN CHART ARE FRAME DIMENSIONS AND 00 NOT INCLUDE FLANGE. MI WINDOWS AND DOORS, LLC 650 WEST MARKET STREET GRATZ. PA 17030-0370 5764 - VERTICAL MULLION 83" MULLION SPAN APPROVED CONFIGURATIONS AND RATING CHARTS DRAWN. DWG W, Rev Y. L. 08-01439 0 77e NTS IE ci I/ I 1/ 12 5ffEFT 2 OF 4 L. ROSERTOLOMASBE. 1432 WOODFORD PIT LEWISVII-LE, NC 270,23 4346680609 r110 vs@irfomapRcm SIGNED: f011312017 okilltittl, / LN tAf OF Luis R. Lomas P.E. FL No.: 62514 I" MIN EDGE DISTANCE MASONRY/CONCRETE BY OTHERS MIN. [MHOMENT 1/4- ELCO ULTRACON TAPCON SUCT5796 CUP OPTIONAL REBAR SECT5764 MULLION MT000022 CLIP 10 WOOD SCREW 1 3/8" MIN, EMBEDMENT 1 ---- WOOD FRAMING/ j 112" LAIN, I 2X BUCK EDGE I— BY OTHERS DISTANCE VERTICAL CROSS SECTION MASOAIRMCONCRF E AND WOOD FRAMING INSTALLA71ON NOTE: CLIPS MAY BE USED IN MASONRY/CONCRETE OR WOOD FRAMiN(; SUBSIRATE, 112" MIN. EDG F DISTANCE VERTICAL CROSS SECTION METAL INSTALLA TION REVISED INSTALLATION DETAILS 06/10/15 F? L, REVISED ANCHORING NOTES el INSTL DE-1 06/07/77 R I- 2 S OR ZILLING, METAL STRUCTURE BY OTHERS MI WINDOWS AND DOORS, LLC 650 WEST MARKET STREET GRATZ, PA 17030-0370 5764 — VERTICAL MULLION 83" MULLION SPAN INSTALLATION DETAILS DPWanc sm. V.L. 1 08-01439 3CALE NTS I flAlE 01/11/12 1 SHEET 3 OF 4 L ROPERTO LOMAS P.E. 1432 WOODFOnD RD LFWISVtLLE, NO 27023 SIGNED: 1011312017 9 L AT OF 6"- OR01t*-- A,: 77`T 0 Luis R. Lomas P.E. FL No.: 62514 L- 0,F43" T-- 3.26 1.375" 625" 3.2 0" 0 O-j 4'0 )0 MT000022 CLIP 16GA (063) GAL VANIZFD STEEL SEE NOTE 2 &3, THIS SHEET. 7.140" 3.750" -- 1 125" 2.189" SECT5764 MULLION 0,843" 2X 00.210" 1.562" 1,562" T ff- 185-2REBAR SECT5796 CLIP 16 GA (062) GALVANIZF0 STEEL FOR WOOD MA—MMATG INSTALLATION ALUMINUM 6063 TS, 125"THICK NOTES: 1, CA-L'S MAY OF USED IN MA5f)T4RY/(:QNCR,l-TE OR WOOD FPAWNG SULIST!"Atf., 2. FOR WOOD & METAL INSTALLATION LIST ALI, FOUR ANCHOR LOCATIONS. 3. FOR CONCRETE INSTALLATION USF 2 ANCHOR tOCATIONS ONLY WITH 3 1/4" SEPARATION PF.fWEf-N ANCHORS, REVISED INSTALLAF!ON MAILS 05/m/ I L P, L. REVISED ANCHORING NOTES & INST11, OE7. 06107117 1 v, I- 3.750" 1.000" - 0.375" 0,4 22, 2,032" 2.875" 0.843" T- SECT5796 CLIP 2)( 00.210" FOR CONCRETE INSTALLATION ALUMINUM 6063-T5. 125'THICK MI WINDOWS AND DOORS, LLC 650 WEST MARKET STREET GRATZ, PA 17030-0370 5764 - VERTICAL MULLION 83" MULLION SPAN COMPONENTS V,L, 08-01439 SCALE NTS I DATE 01111112 1 SHEET 4 OF 4 I ROBERTO tOMASPF 1432 WOODFORD RD LEWISViLLE, NIC 27023 434-686-0609 SIGNED: 1011312017 0111111//// 9 . L R k0- tT/0NAl, 0\\\ Luis R. Lomas P,E. FL No,: 62514 Florida Building Code Online Page I of 3 r'Nfaggi7, BUS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications FBC Staff BCIS Site Map Links Search PApproval Pr' v. v"" use, EEpgMgt oLApplication > ADpliCain Lit > Application Detail FL # FL13223-R4 Application Type Revision Code Version 2017 Application Status Approved Comments Archived Product Manufacturer lames Hardie Building Products, Inc. Address/ Phone/Email 26300 La Alameda Ste. 250 Mission Viejo, CA 92691 909) 349-2927 pingsheng. zhu@jameshardie.com Authorized Signature Pingsheng Zhu pingsheng, zhu@jameshardie,com Technical Representative Pingsheng Zhu Address/ Phone/Email 10901 Elm Ave. Fontana, CA 92337 909) 349-2927 pingsheng. zhu@jameshardie.com Quality Assurance Representative Pingsheng Zhu Address/ Phone/Email 10901 Elm Ave, Fontana, CA 92337 909) 349-2927 pingsheng. zhu@jameshardie,com Category Panel Walls Subcategory Siding Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed Ronald I. Ogawa the Evaluation Report Florida License PE-24121 Quality Assurance Entity Intertek Testing Services NA, Inc. - QA Entity Quality Assurance Contract Expiration Date 2/31/2020 Validated By 3ohn Southard, P.E. validation checklist - Hardcopy Received Certificate of Independence LL 13 2 1 I _ Z_E-tCqLB, -)- tili -cate cif 12,0ep ndence. )of Referenced Standard and Year (of Standard) 5AAndAIS1 ASTM C1186 ASTM E330 year 2007 2002 Equivalence of Product Standards Certified By Florida Licensed Professional Engineer or Architect ELLII3 43-! I4-Egmun- —RI0-26-92B- I http://'NA, ww.floridabuilding.orgl/pr,/pr_app_dtl.aspx?param=wGEVXQNkrtDq\,Rk-6bs\7Z66FC... 2/6/2018 Florida Building Code Online Page 2 of 3 Sections from the Code Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Summary of Products Method I Option D 08/09/2017 08/25/2017 08/28/2017 10/10/2017 FL # Model, Number or Name 13223.1 Cempanel Siding Description fiber -cement panel siding Limits of Use Installation Instructions Approved for use in HVHZ: Yes j2df Approved for use outside HVHZ: Yes Impact Resistant: Yes F 1" Design Pressure: N/A Other: For use inside a HVHZ install in accordance with Verified By: Ronald 1. Ogawa 24121 NOA 17-0406.06 Created by Independent Third Party: No Evaluation Reports FL13223 PA A - NOA 17-049_E,.06j)df FLQ?_2 P4_f LRio _Z68 17 2p el to Furring. ELLLZU R4 AE RIO-2686UZ Pn i&LVfI --r m f — g Createdby Independent Third Party: Yes 13223.2 Hard , ePa ne I Siding fiber -cement panel siding Limits of Use Installation Instructions Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes FL132 - R4 FI NOA 17-0406.Qjt.2 jf Impact Resistant: Yes 21_JR4 ?IO 2689 17 Pane 4 Furrin I Design Pressure: N/A EL_1322"PA 11 RLO-_2686-1_7 Panel Wood M_etaljom pj Other: For use inside a HVHZ install in accordance with Verified by: Ronald I. Ogawa 24121 NOA 17- 0406.06 Created by Independent Third Party: No Evaluation Reports F L 13 2 R L132:ER4AE_ RI 2 6 7 P n I WT I Fr Ti f 1322_3. 3_1P reva,l Panell Created by Independent Third Party: Yes Siding fiber - cement panel siding Limits of Use Installation Instructions Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes FL13223 R4 11 Pr v Impact Resistant: N/A EI-_13223P4 11 RIQ 26 7 P nl _2 Furl iDg_2dJff Design Pressure: N/A LL1_3223 F IRI -268L-j:/_PanelOther: For use inside a HVHZ install in accordance with Verified By: Ronald I. Ogawa 24121 NOA 17- 0406.06 Created by Independent Third Party: No Evaluation Reports FL13223 R4 AE NOA 17-k4_Q.06.pdf FL13 2 .. R4__AE R .2 8- LL-132 Created by Independent Third Party: Yes Kig EE Q_ l :: 2fiQL§jarr Road, Tallahassee F9 Ph n -487- 4 The State of Florida is an AA/EEO employer, a opvrih 7 - f Fl Florida.:: :: ELUSm n :: A si 1, Refund n Under Florida law, email addresses are public records, If you (10 not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, Contact the office by phone or by traditional mail, If you have any questions, please contact 850,487.1395, *Pursuant to Section 455.275( 1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails; provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F. S., please click nS:,e,. Product Approval Accepts: M ie_ E M http:llxA7"-\N%. floridabuilding.orglprlpr_app_dtl.aspx?param=wGEVXQN,,lDqvR-k,6bsvZ66FC... 2/6/2018 Florida Building Code Online Page 3 of 3 C,ed*, Card Safe http://w,ATw.floridabuilding.org/pr/pr_app dtl.aspx9parani=wGEVXQA-tDqNTRk-6bsvZ66FC... 2/6/2018 Florida Product Approv AardiePanelO Siding For use inside HVHZ: o HardiePanel Siding fastener types, fastening schedule, and installation shall be in accordance with the Miami -Dade County Florida NOA 17- 0406.06. Consult the HardiePanel product installation instructions on the follow pages for all other installation requirements. For use outside of HVHZ, o HardiePanel Siding fastener types, fastening schedule, and installation shall be in accordance with Engineering Evaluation Reports RIO-2686-17 or RIO-2689-17. Consult the HardiePanel product installation instructions on the follow pages for all other installation requirements. m N m~°= Hardie Pane 1'"Z1.0, =~~m m~ Vertical Siding W @ EFFECT|VESEPTE 8ER2O13 U |NS lLATO REOU|REW RES|DEN ALSIN GLEF&|'Y'NiY PR|M D COLORPLURaPRODUCTG iug- tot lie mom*cenIversion. SMOOTH° E[RY ULL~ SELECT SIERRA 8 - STUCCO IMPORTANT: FAILURE TO INSTALL AND FINISH THIS PRODUCT IN ACCORDANCE WITH APPLICABLE BUILDING CODES AND JAMES HARDIE WRITTEN APPLICATION INSTRUCTIONS MAY LEAD TO PERSONAL INJURY, AFFECT SYSTEM PERFORMANCE, VIOLATE LOCAL BUILDING CODES, AND VOID THE PRODUCT ONLY WARRANTY, BEFORE INSTALLATION, CONFIRM THAT YOU ARE USING THE CORRECT HARDIEZONE INSTRUCTIONS. INSTALLATION OF HZ1 OTM PRODUCTS OUTSIDE AN HZ1 0' LOCATION WILL VOID YOUR WARRANTY TDDETERMINE WHICH HAR0EZONEAPPLIES TO YOUR 8VISIT WWW.HARDIEZONE,COMORCAL RDE STORAGE &HANDLING: Stot*e flat and keep dry and covered priortoins', d|aion, |nmta||iog ovg wet mxavrated nnay resulti s*hnKagoatnuUjoints. Carry p|anKs on edge, Protect edges and corners mmb,aakaga, James Hardie isnot responsible for damage caused 0yimproper storage and handling of the product. CUTTING INSTRUCTIONS 0UTD0ORS INDOORS i, , Shears, (manual. elecric i) r pneur-atj) NEVER use a power saw inatfors b, Bettel i. post reducing olroular saw equipped with a N P ise a cli-culai, saw blade that does not z,y the Hardio.Blade iax blade trademark Irri,fmart!mote, Fri,ma, arw 0911, k1a""'eslm"'Piralilemwjafne flardle always Using 'Bwnk,Vel CLIM719m VIAtefem u GENERAL REQUIREMENTS: FwCnmmomial HaromPan rvenicamomgomommomlleooverora;ed wood msteel studs; maximum mz" ucSee genernal faromomgrequirements, v/ in framing and sheathing can Mirror through the finished recommends installing HardePano (oioscmenAunmg)unabest poctkm, n1urma0onuninxta|||o0JamosHa,UiepmUvnmnve/foumoenbe|uco1oUmJHToch8uUnUnlBat A /U barrier i | edi i h| |ti!gi i T |V u| mmoaao iseyrii t||U ith nenetratiar, a,c junction flas*ing in accoidance with lcroal building code requireinents. jarnes Hardie voll assume no iesionsiodityfor water intilt. ration. jarnes Wine;,, installing james Hardie products all clearance demils in figs, 5,;6,7,8191 0&11 nnList e followed. gaoentnmmuograde muoslope away /mmmobudding mwccoou/ue with local nu: omgcodes -0o/cv'ywnnmnmmo/ o mthe :/uc /u. Ounot install 1arn uHardie Products, such that they rnarn in con&c with standing water. HardiePanel vertical siding rray be installed on vertical wall applications only, DO NOT use HardlePanel vertical siding in Fascia or Trim ^ ye 3. DO ° lamer- ---- ---base n- i— der coating - ho,owall in gm8oantin n tx.toeUo ge/a rachi± n md k Wmco |Uan oxp monand mo o mn amamo1 opmouctmmoxUou|gn,Thesava|oeoounoa1ounUm|naTm niva|DuU in 8^ p naiunCh ac h km^ww Jamaamanu`ainom ^ INSTALLATION: Joint Treatment Fastener Requirements Ve iou|Join-|ouW|paoo| uinmo0e u1eoon 8 1>t*mative|y PuoiVon u nm 3/8'' hnmpaoeioUgesunUnodox 0mn jnin may ahubmoov udwi 0o mu PVC orm a|/oiNmmor 2''aaayhnmcumou,Don oai|in mmom, caulked uiapp|icab|~ Co|urP|ya=Fi'ich)iq.2). Hd|ePomu|VerhuNQUg|notW\u1iun ' ' Horizontal Joints - Provide Z'8ush|ogat all horizontal }oiWo(fiQ. 3) Framing must Veprovided athohzmnta|and vertical edges for nailing. Figure Figum3 Mar0iePano|vertical siding must bojoined unstud. wate'resrsi' ve barrier °*,°~wv'*iveuam= Double stud may barequired tomaintain minimum edgeut2"p"u nailing distances. Figure fiv barriers sheathing HardicFarielem an mm " Hit Joint verticzl siding m~° banwr from partel edges plat Figure lea. *o u o°" m m' mmv m* Caulk Joint mwmm mntam No, appK U a-ld' aln- x p uenmuz^ | mm^ m;away fron I Corners, For WARNING: AVOID BREATHING SILICA DUST F, JA7 = CLEARANCES Install siding and t! in-, P! odic-ts to N/1---intain, a n"Inimurn i Ntiintain a, min nnum 1 2" clprance At toe linc,,ure oi the roof and vertical Maintain a ,4" Gornpliance with local building code 2" clearance between beivveen James H"ardie products sui faces, flpning andcountellashing I,;arancre between and docking material, shall be instalied per the roofing he bottom of James equvernants to, cicaiance uebveen Jame's Hai diel, manufacturer s ;nstn Ictions, Provide a Hardie products and hc bottom edge of the siding and products aa patios, Figure 7 minimum 2" I-A_naamce heMeen 11oncon tal ,lashing. the adjauent finished grade. steps and driveways. I I ITT—, the redline and the dolct-cq-, edge of the Dcc not caulk gap. Figure 5 concrete 6" min, I fwndatmn Nlainlarn a minimum 1 " gap between gutter end caps and Siding & trim. Figure 9 gutter and end cap Figure 6 1 2" min siong. a! to unin. Figure 8 2" min. I ft" h"g Refer to ;; 9. u, on age 1 . Do not bridge floor; with Haicl2ef`aner sid ng. Hot izorral 0). KICKOUT FLASHING joints shouldakabecreatedbe-ween floors (fig Because of the voluma, of water that can pour down a sloped Water- Resistive I oo", one of the rnost critical fiashina details occurs where a darner Figure 10Horzanial Framing roof Intersects a sidewall . The, Tool must be flashed wish Step flashing. Where the root terminates, install a kickout to deflect Flooring water awayfrom the Siding. It is best to install a self-adherrIg Trim ne onthe wall before ,he suofasca and i' rn boards niernora t arenailedin place, and then come back to install the kickout. Figure 11, Kickout Flashing To prevent viater from durnlIng behind the Siding and the e-,,ul of V roof Sheathing intersection, install a "kickou" as t equir ed by IRC code R90528.3 ",,fasning shall be a min. of 4` high one 4' fascia HardrePanelc wide." James "a:-J2e tecorn rin ends the kickoul be angled between 'M- 1 10' to maximize water defiection BLOCKED PENETRATIONS Penetrations such as hose bibs and holey 1 112" or larger sun as dryer vents should have a block of trimi around point of penetration, GENERAL FASTENING REQUIREMENTS Fasteners must be corrosion resist2n1, galvanized, or stainless steel. Electro-galvanized are acceptable but may exhibit premature corrosion. James Nerd recommends the use of qjalry, hot -dipped galvanized nails. jamess Hardie is not responsible for the corrosion resistance of fasloners. Stainless steel fasteners are recommended when installing James Hardie P!odic-s near the ocean; large bodies of water, or in very humid climates. Consull, applicable product evaluation or listing for correct fastener typee and placement to achieve specific design wind loads, NOTE, Published wind loads may not be applicable to all areas where Local Building Codes have specific jurisdiction, Consult James Hardie Technical Services if, you are Ljqsu,,-, a" applicable compliance documentation. Drive fasteners percendicular to siding and framing, Fastener heads should fit, snug against siding (no air space), (fig. A) Do not over - drive nail heads or drive nails at an angle, If nail is countersunk, fill nail hole and add a nail, (fig. 13) For wood framing, under driven nails should be hit flush to the plankvvith a harmer {for steed framing, remove and replace naill. NOTE: Whenever a sTructural me,nber is, c--esent, HardiePiank s-n-ulc be fastened with eve - spacing to the structural rnembel'. The tables allowing di,ec-, t3 OSE 3rplywood should only be used wlen traditi- 1al framing is not available, Do not use aluminum fasteners, staples, or clipped head nails. Snug Flush 97, 71 Countersunk, fill & add nail Figure A Figure 6 do notunder drive nails DONOT STAPLE James Hardieproducts can be hand nailed or fastened with a pneumatic too[. Pneumatic fastening is highly recommended. Set air pressure so tfat the fastener is driven snug w0h the surface of the sidinc. A flush mount attachment on the pneUrnatic tool is reGO" flnien0ed, his Will help 001nt!*01 the cteptril the nail is drrver. If, setting the nail depth o,'cves diffic-11, choose a setting that under drives the hall. (Drive under driven nails snug w th a s rooth faced ham^)er - Does not apply tat, installation to steel frarning). HS1236-P2/3 8113 CAULKING Fm results use Jnin tSealant cornpiyno vvith AS'FM C920 Grace NS.Class 25 or higner or a Lalex joint Sualamoomplyin hAGVWC8J4. Cuu| NnQ naiantmua\beapplied ioaucu,doocowKhthe cuo|king oa Vmmmacbnv'xw;eninstructions, Note: OSIQuad auveUauuummother caulking manufacturers Uonot allow tooling. DO NOT caulk nail heads ,klherr using ' ColorPlus products, refer to the 11"olorPlus 'ouch -up section CUT EDGE TREATMENT PAINTING Cau|k.pairil, mprime all field cut edges. DUN0Tuse stain, uil,ialkydbase paint .wpmw-IeruoaUngunjano Hardie ProdUCtS. James Hardie products JamoyHardie touch-up kits are required U must kapainted witiniol8OUay u primed, product uoUBOdays for uoprimad.l0O oc/Wpccattsare mc mengoU Duo paxxm an gRrapp|ica mmmue Np mou c,omu o| u on uNuch-,pCu|o/P!oypmUoc|y '/ , DaU+mUmg iuecmnmonUeU Kthe siding is sprayed. COLOAPLHS"TECHNOLOGY CAULKING, TOUCH-UP & LAMINATE Co,,eshould betaken when handling and cutting James Hardie(&ColorP|uo(DR products. During installation use nwet soft cloth msoft brush 1n gently wipe off any residue or construction dust left on the product, then rinse with a garden hose. Touch upnicks, scrapes and nail heads using the Co|orP|us"',Technology kmck-u'a0p|ica cTouch- up should bcused mdog U|a oamaamqui uch'up.re aon odamaged amaw knew Ma/UioPane|siding with Color -Plus Technology. Laminate sheet must Ueremoved immediately after installation ofeach course. T&nninatennn'factoryuutndges|nlothmw0empmmiNa.anUoau|k.Co|o/matcAedcauiksammmi|uh|nfmmyourCo|orP| uo-`pmUuctdea|oc Treat all other non -factory cut edges using the ColorPlus Technology edge coaters, available from your ColorPlus product dealer, Note: James Hardie does not warrant the usage of third party touch-up mpaints used as touch-up onJames Hardie ColorPlus products. PmNomo ith appearance mpefformance arising from use of Third party touch-up paints orpaints used as touclh'up that are not James Hardie 1oucA'uV.will not bacovered under the James Hardie CNorP|uxLimited Finish Warranty. Tfie following outlines the recommended applications for ColorPlusand Primed panels, Not all designs will besuitable for every application: ExpmooUfasteners mbattens is the mnonmendodapplication for Co& rP|uopanel products Do not use touch-up over fastener heads for smooth ColorPlus products - primed panel recommended For ColorPlus panel applications that requlire fasteners in the field, it is acceptable to use trourch- up over fasteners for Cedarmill arid Stucco panel on but coneotouch-up opp||oa8onioimpmn n1. Some c ommayshow touch-up when applied er a nem,Thn!io cummenUod1nouo/ joints when appropriate. PAINTING JAMES HARDIE"SIDING AND TRIM PRODUCTS WITH COLORPLUS' TECHNOLOGY VVIien repainting ColorPlus products, James Hardie recommends the following regarding surfacepreparation and topcoat application: Ensure the surface isclean, dry, and free ofany dust, dirt, urmildew RepriminDionormally not necessary 1OU%acrylic topcoats are recommended DONOToxostain.oi|/a|kyUbauepaiot.orpowUo/cuaUngonJamouHardio"'Pmdur-As Apply finish coat in accordance with paint manufacturers written instructions regarding coverage, application methods, and application temperature z* u Hl!,Jiopane Veranal mm fu m 248 11, atemFloraA U n, mm,@xcwNc,m*r29,U. usDwt,ummwmrarsnm=v12eDo 3rtrreli of owmNe"t;v*wm2o S-w.and oSAm 10 umoJanesHardie awmrigp^ All rights res= rc. m Additonal Installation Nfonno oo w u mmrw oN&ao and ,"m'ngnareavailable fie mm/xm o L mo uumummo —"_a UNTY A , LAWRATORY ACCREDITED July 30, 2017 Pingsheng Zhu, P.E. Product Compliance Engineer James Hardie Building Products 10901 Elm Ave. Fontana, CA 92337 Relative to FBC 2017 Project RIO-2679AA-17 Dear Pingsheng, After review of the 2017 FBC, it is my opinion that the current NOA-17-0406.06 is in compliance with the 2017 Florida Building Code, Referenced Standards in the 2017 FF3C, 1, Wood: AVVC NDS-2015 & SDPWS-2015 2, Structural Loads: ASCF-ISEI-7-10 3. Concrete: ACE-318-14 4. Masonry: TMS402-20161AC1530-laiASCE-5-13 51 Structural Steel: AISC 360-10 (Including manual of steel construction 2010 (14" edition)) 6, Cold -formed Steel: AISI 100-12 7. Aluminum: ADM-1 -2015 In addition, I am making the following Statement of Independence as requested: 1 Ronald 09awa, does not have nor does it intend to acquire or will it acquire any financial interest in any company manufacturing or distributing products for which evaluations are issued, Z Ronald Ogawa is not owned, operated or controlled by any company manufacturing or distributing products it evaluates or inspect, I Ronald Ogawa inc does not have, nor will it acquire a financial interest in any company manufacturing or distributing products for which reports are being issued- 4, Ronald 09awa does not have, nor will it acquire a financial interest in any other entity involved in the approval process of the product. Should you have any questions on anything, please contact me. Sincerely, Ronald 1. Cigawa, P. RI Ogawa & Associates, Inc. JAS Laboratory Approval, TL 360 IAS Quality Control Agency, AA-705 CRRC Approved Testing Laboratory for Solar Reflectance and Emissivity State of Florida Approved Validator and Third Party Quality Control Agency 714) 292-2602 ion r jo a ,L, a cone CC: Roger Ogawa — RI 09awa & Associates, Inc, Karen Ogawa — RI 0gawa & Associates, Inc, if 'ff r'fj1tff" 01 sslotIM, —111 IT111111"OfIr"101 Lab Address: 1985 Sampson Avenue. Corona, CA 92879 * Phone (714) 321-4939 * Fax (714) 90 15-181 5 a E-mail: Lo Maiiinl;i Address: 16535 Algonquin St #443, Huntington Beach, CA 92649 * Phone (702) 01-3710 * Fax (714) 909-1815 * E-mail: debbyQ:L,,g;Lwa L.2, m Engineering * QuaNty Control 9 Product Development a Inspections * Code Consulting a Expert Witness * Testing MIAMI- MIA.MI-DADS COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 331115-2474 BOARD AND CODE ADMINVISTRATION DIVISION T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.goy/economy James Hardie Building Product, Inc. tl 10901 Elm Avenue Fontana, CA 92337 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER-Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AI -LT). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone, DESCRIPTION: "Hardie", "Cem" and "Prevail" Planks and Panels Fiber Cement Siding and Soffit APPROVAL DOCUMENT: Drawing No. PNL, PLK & SOFF, titled "HardiePanel, CemPanel, Prevail Panel; HardiePlank-, CemPlank Prevail Lap Siding; HardieSoffit, CemSoffit Panel; Installation Details Wood/Metal Stud Construction", sheets I through 12 of 12, dated 04/24/2013, prepared by the manufacturer, signed and sealed by Ronald I. Ogawa, P.E., bearing the Miami -Dade County Product Control renewal stamp with the Notice of Acceptance number and expiration date by the Miami -Dade County Product Control Section. MISSILE IMPACT RATING, Large and Small Missile Impact Resistant LABELING: A permanent label with the manufacturer's name or logo, Plant City, Florida, and the following statements: "ASTIM C 1186 Type A compliant" and "Miami -Dade County Product Control Approved" is to be located on each siding plank or panel and per FBC 1710,9.2 and 1710.9.3 on Soffit panels. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA # 15-0122.04 and consists of this page I and evidence page E-1, as well as approval document mentioned above. The submitted documentation was reviewed by Carlos M. Utrera, P.E. NOA No. 17-0406.06 MIAMI, COUNTY Expiration Date: May 1, 2022AN-6 NOW Approval Date: May 4, 2017 1 , 2017 Page I James Hardie Building Products Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED A. DRAWINGS "Submitted under ArOA # .13-0311.07" 1. Drawing No. PNL, PLK & SOFF, titled "HardiePanel, CemPanel, Prevail Panel; HardiePlaiik-, CemPlank Prevail Lap Siding; HardieSoffit, CemSoffit Panel; Installation Details Wood/Metal Stud Construction", sheets I through 12 of 12, dated 04/24/2013, prepared by the manufacturer, signed and sealed by Ronald 1. Ogawa, P.E. B. TESTS "'Submitted under AVA # 13-0311.07" 1. Test reports on 1) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 2) Cyclic Wind Pressure Loading per FBC, TAS 203-94 along with marked -up drawings and installation diagram of HardiePlank, HardieSoffit and HardiePanel, prepared by Intertek Testing Services NA LTD, Test Report No. 100733361COQ-004, dated 08/2412012, with revision I dated 04/25/2013, signed and sealed by Rick Curkeet, P.E. Submitted under NOA # 02-0729.02" Laboratory Report Test Date Signature 2. ATI-16423-1 PA 202 & 203 03/18/96 A. N. Reeves P.E. 3. ATI 16423-2 PA 202 & 203 03/18/96 A. N. Reeves P.E. 4. ATI 16423-3 ) PA 202 & 203 03/18/96 A. N. Reeves P.E. C. CALCULATIONS 1. None. D. QUALITY ASSURANCE 1. Miami -Dade Department of Regulatory and Economic Resources RER) E. MATERIAL CERTIFICATIONS 1. None. F. STATEMENTS "Submitted under N, OA # 15-0122.0411 1. Statement letter of code conformance to the 5"' edition (2014) FBC issued by Ronald 1. Ogawa & Associates, Inc., dated 10/26/2014, signed and sealed by Ronald 1. Ogawa, P.E. Carlos M. Utrera, P.E. Product Control Examiner NOA No. 17-0406.06 Expiration Date: May 1, 2022 Approval Date-, May 4, 2017 E - I BY PRODUCT RENEWED as complying with the Florida Building Code NOA-No. 17-0406.06 Expiration 5te, O05 1/2022 By Miami-Dacfe Product Control REVIND a*Jbl * we Ce" No I-q1 122- WALL LENGTH — Stud Spacing at 16" O.C- 13-4— 1 1 1 M Nails at 16, O.C. (typ.) 3/8" Minimum Edge Distance Sheathing fastener, as described in Note I Panel fastener, as described in Note 2 HardiePanel, CemPaMel, Prevail Panel Siding Water -resistive barrier per Florida Building Code Section 1404.2 5f8" thick / 5 ply APA rated plywood sheathing fastened in accordance with Florida Building Code Section 2322.3 2" X 4!' S-P-F Wood Studs The wall and soffit frames are to be designed by the Architect or Engineer of Record in compliance with the Florida Building Code. SEE DETAIL A 5/8" thick 15 ply APA rated Iplywood sheathing in accodance, with Florida Build'ing Code Sectionnr'23222 Water -resistive barrier per Florida Building Code Secfon 1404.2 TX 4' S-P-F Wood Studs PlIallmT —jxwM-RQ" HardiepanelO, CempaneM, & PrevailO Panel Siding materials are nonasbestos fiber-f.Tarnent Products tested in accordance with ASTM C1 186 Grade 11, Type A and meeting the requirements ofthe Florida Building Code. PANEL E4VE width Length Thickness 41 8,9,101 5116" jJESIGN installation Design Pressure Wood Studs -76 psf H,rdj,,p.rj' Impact Resistant- Tto tH Cernpanel, Planks installed over -KUT" thick / 6 ply Prevail Panel APA rated plywood sheathing Siding 0ARDt1YFA AL CEMWP-9EYA ' All installation shell be done in conformance with this Notice of Acceptance, the manufacturers Installation recommendations, and the applicable sections of the Florida Building Code. Wood studs where HardiePanel, Cempanell, Prevail Panel Siding v; 11 be installed shall be designed by an Engineer or Architect per the Florida Building Code and the requirements of this N.OA attached to the studs in Note i] 51T thick 15 ply APA rated plywood sheathing shall be accordance writh Florida Building Code Section 2322-3. The siding panels shall be installed over 5/8' thick 15 ply APA rated plywood Sheathing supported by a minimum of 21IX4" S-P-F wood studs spaced a maximum Of 16" O.C. Note 2] The siding panel fastener shall be a 2" long, 0223!' head diameter, o.092" shank diameter, corrosion resistant siding nail; the fasteners shall be spaced at V, O.G. at panel edges and intermediate studs; the fasteners shall be driven through the 518" thick 15 ply APA rated plywood sheathing into wood studs located at 16!'O,C. Fasteners shallhaveaminimumedgedistanceof318" and a minimum clearance of 2" from comers. ID HARDIEPANEL, CEMPANEL, PREVAIL PANEL INSTALLATION DETAILS WOOD STUD CONSTRUCTION James Hardie Building Products, Inc. 10901 Elm Avenue Fontana, CA 92337 Phone: 909- 356-6300 FSCM NO MIG NO Rel Fax 909- 427-0634 A PNLrPlj(-SOFF 1 Creator. E. Gonzales SCALE Dat6:4/2412013 SHEET I OF 12 Fastener spacing per Florida Building Code Section 2322.3 i ali9ins Code ACCOPUNW No %0-1W2. Z ' t 14WD1JCT REVMM f 1, e7 ram ' G?z El- .1 C]2ddl;ig A-1 W Framing SheathingFastenerSpaclingperFlorida Building Code Section 2322.3 x PRODUCT RENEWED 7Z as complying with the Floridaida Building Code NOA-No. 17-0406.0606 z Ex Irallo" o05101120C22 By0 Mi. 4..t Control 4.... .. SION V EgAIMINIQ * NOMINAL 2" X 4" S-P-F WOOD STUDS 16" O.C, FASTENED WITH 3-112" 16d COMMON NAILS (2 PER TOP AND BOTTOM CONNECTION) THE WALL AND SOFFIT FRAL19S ARE TO BE DESIGNED BY THE ARCHITECT OR ENGINEER OF RECORD IN COMPLIANCE WITH THE FLORIDA BUILDING) CODE gi-aEAT-HUNG NOMINAL 5/8" THICK/ 5 PLY APA RATED PLYWOOD SHEATHING FASTENED IN ACCORDANCE WITH FLORIDA BUILONG CODE SECTION 2322.3 qL&QQ-t?Wi THE PANEL IS FASTENED WITH 2" LONG, 0.223" HEAD DIAMETER, 0.092!" SHANK DIAMETER, CORROSION RESISTANT SIDING NAILS, PLACE NAILS 6'0.C. AT PANEL EDGES AND INTERMEDIATE STJDS FOR METAL AND WOOD STUDS, PROVISIONS FOR DIAPHRAGM ACTION AND GRAVITY LOAD ARE NOT PART OF THIS APPROVAL (MUST PROVIDE ALTERNATE PROVISIONS FOR THESE LOADS) ll 1.,,--V-,'ALL LENGTH Stud Spacing at 16" O.C. G 0yni Vi!h IQ norw* 130 'Cc,& No, WALL iLIGHT STATE 40M ONA' r----- --- Nails at T O.C. (typ) 318" Minimum Edge VsWce PE-TN,L-A- The FkVida I%b PRODUCT RENEWED as complying with the Florida Building Code NOA-No. 17-0406.06 SEE DETAIL A 5/8"thlclk 15 ply ArA rated plywood sheathing fasteAed to metal studs as do -scribed in Note I Water-resistive barrier per Florida Building Code Section I404.2 20ga, 3-5J8" X 1-518" Metal C-stud RR-Q1!Q-(j-D-E5 Q R! P T P N HardlePanelO, GempaneIV, & PleVai* Panel Siding materials are nonasbestos fiber -cement products tested in accordance with ASTM C1 1 M Grade It, Type A and meeting the requirements 0 the Florida Building Code. FANTjLQLWEN$j-Q1NS Width Length Thickness 4' 8,9,10' 5/1611 installation Design Pressure Metal Studs -104 psf flv I Impact Resistant - fili L-11 HardiePariel, Panel installed over 618" thick / 5 Ply Campanel, APA rated plywood sheathing Prevail Panel Siding jAp Qjj- o t- qwe&ma _ t - -ICN-PE-TA31$ All installation shall be done in conformance with this Notice of Acceptance, the maniffarAuriers Installation recommendations, and the applicable sections of the Florida Building Code. Metal studs where HarcliePanel,.Cempanel, Prevail Panel Siding will be installed shall be Sheathing fastener, as designed by an Engineer or Architect per the Florida Building Code and the requirements of this described in Note 1. N.O.A. a [ Note 1] 518" thick 15 ply APA rated plywood sheathing shall be attached to metal studs at 6"oo at panel edges and all Intermediate supports using a No.8-18, 0.315" head diameter x 1-114' long Panel fastener, as described In bugle head screw Note 2 0 The siding panels shall be installed over 518" thick / 5 ply APA rated plywood sheathing supported by a minimum 209a, Nominal 3-518" X 1-51811 Meta; C-studs spaced a maximum of 16" O.C. V [Note 2] The siding panel fastener shall be a minimum No. 8-18, 0.315" head diameter X 1-5/8" HardjePaneliV Siding long* ribbed bugle head screw (*or screw shall have at least 3 full threads penetrating metal framing); the fasteners shall be spaced at 6" O.C. at panel edges and Intermediate studs-, the fasteners shall be driven through the 5/8" thick 15 ply APA rated plywood sheathing into metal Water -resistive barrier per studs located at 16'O.C. Florida Building Code Section Fasteners shall have a minimum edge distance of 3181 and a minimum clearance of 2" from 1404.2 comers, VAIL PANEL w HARDIEPANEL, CEMPANEL, PR ti INSTALLATION DETAILS METAL STUD CONSTRUCTION 518" thick 15 ply APA rated plywood sheathing fastened Ej Mj James Hardie Building Products, Inc. to metal studs as descftad 10901 Elm Avenue in Note 1. Fontana, CA 92337 Expiration D e05 /2022 20ga, 3-518'"X 1-5/3" Metal C-stdd The wall and soffit frames are to be designed By_ by the Architect or Engineer of Record in Miami -76ade Product Control I compliance— with the Florida Building Code. hone: 90956 630Ci s FSCM)40 OWS, 40 REV Fax 909- 427-06 4 1 PNL-PLK-SOFF 1 1 Creator, E. Gonzales I SoALr- 1/2" - T-0- I Date: 412412013 1 SHEET 3 OF 12 6.00h PRODUCT RENEWED as complying with the Florida Building Code 40A-No. 17-0406.06 Expire 05/0112022 3y PRODM'T REVLqFD WM*yipzWiIhftF%6ft Ehowirs Co& Act NO I I 0' M7 Il'y I. iI Il T Pjj0vtjfT a ov*yins With ire IFS f:j AMINIQ NOMINAL 20 GAUGE 3-5/8!'X 1-518" STEEL STUDS 16" O.C. FASTENED WITH 5/8WAFER HEAD SCREWS (2 PER TOP AND BOTTOM CONNECTION) TO BE DESIGNEDTHEWALLANDSOFFITFRAMESARE BY THE ARCHITECT OR ENGINEER OF RECORD IN COMPLIANCE WITH THE FLORIDA BUILDING CODE SHF NOMINAL 518" THICK / 5 PLY APA RATED PLYWOOD SHEATHING To METAL STUDS AT 6" OC AT PANEL EDGES AND ALL INTERMEDIATE SUPPORTS USING A NO.8-1 5, 0.315- HEAD DIAMETER X 1 -1 J4' LONG BUGLE HEAD SCRIEVV qjAqQVNG -18, 0.315" HEADTHEPANELISFASTENEDVJITHNO. 8 DIAMETER X 1-5/8' LONG CORROSION RESISTANT ROBED BUGLE HEAD SCREWS (SCREW SHALL HAVE: AT LEAST 3 FULL THREACS PENETRATING THE METAL FRAMING), pLACF SCQ Ews 6,, O.C. AT PANEL EDGES AND INTERMEDIATE STUDS Cladding Framing II Sheathing OGA kN % 121 EOF FOR METAL AND WOOD STUDS, PROVISIONS FOR DIAPHRAGM ACTION AND GRAVITY LOAD ANOTPARTOFTHISAPPROVAL (MUST PROVIDE ALTERNATE PROVISIONS FORT HESE LOADS) RE: I T WALL P FQDLIGI-PE%11 -J!Zt4 VVALL LENGTl+---------- Stud Spacing at 16" O.C. DETAIL A HardleFllankO, Cemplank(D, 04 prevallo plank Lap Siding mate(1815 1 T --------------- 1 ----- — -------- 1 1 5/81, thi& 15 pAPA are nonasbestos fiber -cement rated p wood ly products tested in accadance with ASTM cl 186 Grade It, Type A and L= a 3/ 4" Minimum Edge Distance Q) TML.A PRODUCT RENEWED as complying with the Florida Building Code NOA- No. 17-0406.06 witb # Fk?ri& 7 A1 Neils at 16' O.C. (ty Sheathing fastener, as described in Note I Siding fastener, as described in Note 2 HardiePlank, Cemplank, Prevail A— Lap Siding Water - resistive barrier per Florida Building Code Section 1404.2 51a" thick 15 ply APA rated plywood sheathing fastened in accordance with Florida Building Code Section 23223 Expiration ripteO 01/2022 2"X 4" S-P-F Wood Studs The wall and soffft frames are to be designed By by the Architect or Engineer of Record in Miami ,b I5he Product Control compliance with the Florida Building Code. Isheaming in meeting the requirements of tl le accordanWithFloridaBuildingCode. Florida Building Code Section 2322.3 PARf;pIRwslm Water - resistive Width Length Thickness bamer per Florida 5116" Building Code section 14C4-2 Ur\ 2" X 4"S-P-F Nood Studs Lap Siding 1 . 114' tall X 5/16" thick starter Strip installation- Design Pressure Wood Studs -92 psf Impact Resistant - Planks installed over S/V'thick / 5 ply APA rated plywood sheathing HARDII; EL&NK,qEMELA NKJPBINIMLLLAP AILS SAll installation shall be done in conformance with this Notice of Acceptance, the manufacturers installation recommendations, and the applicable sections of the Florida Building Code. WoodstudswhereHardieplank, Cempl?nk, Prevail Lap Siding will be installed shall be designed by an Engineer or Architect per the Florida Building Code and the requirements of this N,OA Note 115/81, thick 1 5 ply APA rated plywood sheathing shall be attached to the studs in accordance with Florida L3u!)djng Code Section 2322.3. course of the wall with !-IWA4de Planksshallbeappliedhorizontallycommencingfromthebottom00laps at the top of the plank such that the 0XPOWe area Of each plank is 8-14'vertically. Note2) The siding fastener shall be a 2-1112' long, 0,223" head diameter, 0-092" shank diameter, corrosion -resistant siding nail; The siding is fastened f. 8-114" O.C. vertically and 16'0.C. horizontally; fastenersaredrivenintowoodstudsthrough51s" thick / 5 ply APA rated plywood sheathing, fasteners are placed jr, the overlapping area approximately 3144 from the bottom edge of the overlapping plank. Vertical joints shall be placed over studs. TheplanksshallbeinstalledoverSIS!'thick 15 ply APA rated plywood sheathing supported by a minimum of 2"X4" 8-P-F wood studs spaced a maximum Of 16" O-C- Fasteners shall have a minimum edge distance of 316'. Fastener Spacing per Florida 0 CladdingRBuildingCodeSection2322.316 in. Framing 7 --- - -------------- FastenerSpacing per Florida Sheathing PRODUCT RENEWED Building Code Section 2322.3 as complying with the Florida NOA- No. 17-0406 Building Code .06 0. 7 Sin Expiration Dote 0510112022 By Miami-[ Yadk- Product Control m ownplying with 1hv flmi& 6t6jdin8C0& Am- rotmw No T[— Bn ER& MNQ NOMINAL 2" X 4" S-P,F WOOD STUDS 16" O.C. FASTENED WITH 3-112" 16d COMMON RAILS (2 PER TOP AND BOTTOM CONNECTION) THE WALL AND SOFFIT FRAMES ARE TO BE DESIGNED BY THE ARCHITECT OR ENGINEER OF RECORD IN COMPLIANCE WITH THE FLORIDA BUILDING CODE SHEAT G NOMINAL 518" THICK / 5 PLY APA RATED PLYWOOD SHEATHING FASTENED IN ACCORDANCE WITH FLORIDA BUILDING CODE SECTION 2399.3 9- AADJ M- PLANKS OVERLAP 1-114" THE EXPOSURE IS 58-1/4" THE PLANKS ARE FACE NAILED WITH 2-1/27 LONG, 0.223' HEAD DIAMETER, 0.092" SHANK DIAMETER, CORROSION. RESISTANT SIDING NA)LS,-PLACED 3/4' UP FROM THE BOTTOM EDGE OF THE PLANKAT EACH STUD LOCATION OD MoDUC17 JIFIVISED, ior asNo. 21 By ' z ' 0 STATE OF ode Pmdwl 0 NAL FOR METAL AND WOOD STUDS, PROVISIONS FOR DIAPHRAGM ACTn10 LOAD ARE NOT PART OF THIS APPROVAL (MUST PROVIDE ALTERNATE PROVISIONS FOR THESE LOADS) HARDIEPLANK, CEMPLANK, PREVAIL LAP SIDING INSTALLATION DETAILS WOOD STUD CONSTRUCTION James Hardie Building Products, Inc. 10901 Elm Avenue Fontana, CA 92337 jj-- I frtCM No DAIG NO PN AL-PLK-SOFF Stud Spacing at 16' O.C. WALL VALL IGKT 4-- i wijb,6w Y A IV UY 4114- M 6 I-ATa OF A, -------- ------- _ B 3W romhum Edge Distance Nails at IQ" C.C. (typ) DETAIL A Sheathing fastener, as described in Note 1 C4X* M W 4791 Siding fastener,as described in Note 2 HardiePlank, Cemplank, Prevail Lap Siding PRODUCT RENEWED as complying with the Florida Building Code NOA-Ho. 17-0406.06 Expiration 05/01/2022 By Miami-Dfidfb Product Control i Water -resistive barrier per Florida Building Code section 1404.2 51811 thick 15 ply APA rated plywood sheathing fastened to metal studs as described in Note I 20cia 3-518" X 1-5/T Metal C-stud The wall and soffit frames are to be designed by the Architect or Engineer of Record in compliancle with the Florida Building Code. SEE IIRQQL9C MQ Q PT 0 __Rt_,L JJ DETAIL A HardiePlankO,,CemplankO, and N 518" Nick 15 ply APA Prevail? Plank Lap Siding materials 1 5 rated plywood are nonasbestas fiber -cement sheathing fastened products tested In acoordancevvith to metal studs as ASTM C 1186 Grade 11, Type A and meeting the requirements of thedescribedinNoteI Florida Building Code, Water -resistive barrier per Florida aL_ALRK DIMENSIONS Building Code Width Length Thickness 7Z Section 1404.2 5 9-112" 121 5/161, 20gi, MWX 1-518" DESIGN PREASINR __RAE Metal C-stud TJ,%j Installation Design Pressure Hardiel"Jank, Cemplank, kfaR Metal Studs -92 psf Prevail C 10 Lap Siding Impact Resistant - 1-1/,V tall X 5116" Planks installed over 5/8" thick / 5 ply thick starter strip APA rated plywood sheathing HARDIEPLANK CEMP PREVAIL_LAP DETAILS All installation shall be done in conformance with this Notice of Acceptance, the manufacturer's installation recommendations, and the applicable sections of the Florida Building Code. Metal studs where HardiePlank, Cemplank, Prevail Lap Siding will be installed shall be designed by an Engineer or Architect per the Florida Building Code and the requirements of this N.O.A. Note 1] 5/8" thick / 5 ply APA rated plywood sheathing shall be attached to metal studs at 6'oc at panel edges and all intermediate supports using a No,8-18, 0.316'head diameter x 1-1/4' long bugle head screw Planks shall be applied horizontally commencing from the bottom course of the wall with 1-114"wide laps at the top of the plank such that the exposure area of each plank is 8-1/4" vertically. INote 2) The siding fastener shall be a minimum No, 8-18, 0,315" head diameter X 2-1/4" long* bugle head sorew over metal studs {*or screw shall have at least 3 full threads penetrating metal framing); The siding Is fastened15 8-1/4" O.C. vertically and 16" O.C. horizontally; fasteners are driven into metal studs through 5/8" thick 15 ply APA rated plywood sheabiing,'fasteners are placed in the overlapping area approximately 3/4' from the bottom edge of the overlapping plank- Vertical joints shall be placed over studs. The planks shall be installed over 5/8" thick 15 ply APA rated plywood sheathing supported by a minimum 20ga, Nominal 3-5/8" X 1-5/8" Metal C-studs spaced a maximum of 16" O.C. Fasteners shall have a minimum edge distance of 3/8", 6.00in. PRODUCT RENEWED as complying with the Florida Building Code NOA-No. 17-0406.06 0.75in A— I, Expiration Date 05/0112022 By Miami-rfatfe Product Control to cwins &C fhri4a W1& 4 Ql.4e Acccptmce No FRAisiilNG NOMINAL 20 GAUGE 3-5/8" X 1-5/8" STEEL STUDS 16" O, C. FASTENED WITH 518" LONG RIBBED BUGLE HEAD SCREWS ( 2 PER TOP AND BOTTOM CONNECTION) THE WALL AND SOFFIT FRAMES ARE TO BE DESIGNED BY THE ARCHITECT OR ENGINEER OF RECORD IN COMPLIANCE WITH THE FLORIDA BUILDING CODE iaj;& T131"P NOMINAL, 518" THICK / 5 PLY APA RATED PLYWOOD SHEATHING TO METAL STUDS AT 6"QC ATTANEL EDGES AND ALL INTERMEDIATE SUPPORTS U8114G A NO3- 18, 0,315" HEAD DIAMETER X 1-1/4' LONG BUGLE HEAD SCREW PLANKS OVERLAP 1-1/41 THE EXPOSURE IS 8-1/4" THE PLANKS ARE FASTENED WITH NO. &-18, 0,315" HEAD DIAMETER X 2-1/4"LONG CORROSION - RESISTANT R199ED BUGLE HEAD SCREWS (SCREIN SHALL HAVE AT LEAST 3 FULL THREADS PENETRATING THE METAL FRAMING), PLACED 3/4" UP FROM THE BOTTOM EDGE OF THE PLANK AT EACH PTi in I 0(',ATInN 6 Ill. T- 6, 00in.OG REVISED risq; with the Fkxidks Cot* No a Cladding Framing Sheathing FOR METAL AND WOOD STUDS, PROVISIONS FOR DIAPHRAGM ACTION AND GRAVITY LOAD ARE NOT PART OF THIS APPROVAL (MUST PROVIDE ALTERNATE PROVISIONS FOR THESE LOADS) HARDIEPLANK, CEMPLANK, PREVAIL LAP SIDING INSTALLATION DETAILS METAL STUD CONSTRUCTION James Hardie Building Products, Inc. 10901 Elm Avenue It Fontana, CA 92337 Sit-. rSom NO O'Ar No REV Fax 909-427-0634 PNL-PLK-SOFT a Creator: E. Gonz:ale sG'J:z 1" = 1'-0" Date: 41241Z013 1"I FT 8 OF 12 WALL LENGTH Stud Spacing at 16" O.C. V WALL iEl HT': PRODUCT RENEWED as complying with the Florida Building Code NOA-No. 17-0406.06 Expiration p;Oe05/01/2022 X_ 3,18" Minimum SEE DETAIL A Hardie-SoffitO & CemsoffiM materials are nonasbestos fiber -cement products tested in accordance with ASTM C1 186 Grade 11, Type A and meeting the requirements of the Florida Building Gode. SOKIT Pj?.W14qtQNq 2"X 4'S-P-F Width Length Thickness wood Studs 4, a 114" LtEiN _RATJ-bl.Q HardieSoffiL Installation Deslgn Pressure h/ cemsom Wood Studs -70 psf QGAW 4 21 j STATE OF N A\- I f4f HA9QIEST! 0f I !ZEMSC EJET -NELit$-T,-Aj-J-A--TJS:aETAIL s , , Soffit fastener, as X All lnstallation shall be done in conformance with this Notice of Acceptance, the manufacturer's described in Note I installation recomm"clations, and the applicable sections of the Florida Building Code. Wood studs where HardieSoffit Cemsoffit will be installed shall be designed by an Engineer or Architect per the Florida Building Code and the requirements of this N.O.A. HardieSoffit, Cemsoffit * The soffit shall be installed over minimum 2"X4" S-P-F wood studs spaced a maximum of 16" 0. C, Note 11 The soffit fastener shall be a 2" long, 0.223" head diameter, 0.0920 shank diameter, corrosion resistant siding nail; the fasteners shall be spaced at 4!'O.C. at panel edges and intermediate studs,* the fasteners shall be driven into wood studs located at 16" 01 C, s Fasteners shall have a minimum edge distance of 3/8" and a minimum clearance of 2" from coniers. Nails at 4" C.C. (t/P-)PR0DUCf "Vmw PIZO'Cry Distance - -0mlyiug -ith dw Floriiii M a1voirift with Ike Flo" 13,ad* C,4- 9*1&V coik AOMVUWM NO Aypte N[3-03 1e— N*;= E, irmJacoZT' 4y 7Product CM jPTtqi Minimum 2" X 4" S-P-F Wood Studs The wall and soffit frames are to be designed by the Architect or Engineer of Pecord in compliance with the Florida Building Coda. REV I PRODUCT RENEWED as complying with the Florida Building Code NOA-No. 17-0406.06 Expiration Date 05/0112022 By Miami- Product Control PRODUCT REVIa ow0ying wift ibc fuc;& 2cs wmplyiAig with die fkwf& 8" T* CIO& gfildimcoft : '— AemplAfto N, A=Cvtal ft ?4 E& 12- v3 EVI. * mkm kDftz,2 /1.;2017 0* P/T E—M— MNQ NOMINAL 2" X 4?'S-P-F WOOD STUDS 16" O.C. FASTENED WITH 3- 1/2' 16d COMMON MAILS (2 PER TOP AND B0170M CONNECTION) THE WALL AND SOFFIT FRAMES ARE TO BE DESIGNED BY THE ARCHITECT OR ENGINEER OF RECORD IN COMPLIANCE WITH THE FLORIDA BUILDING CODE THE SOFFIT IS FASTENED WITH 2- LONG, 0.223" HEAD DIAMETER, 0. 09Z SHANK DIAMETER, CORROSION RESISTANT SIDING NAILS, PLACE NAILS 4!'O.C. AT PANEL EDGES AND INTERMEDIATE STUDS Cladding Framing GAN STATE OF S '. 4t 8/0NFORMETAL AND WOOD STUDS, PROVISIONS FOR DIAPHRAGM ACTION AND GRAVITY LOAD ARE NOT PART OF THIS APPROVAL (MUST PROVIDE ALTERNATE PROVISIONS FOR THESE LOADS-) Fax 909- 427-0634 A PNL-PLK-SOFF Creator: E, Gonzales SCALS Date: 4/24/2013 B E CT 10OF 12 ESHI RFVI WALL LENGTH JJ Stud Spacing at 16" O.C, B-<-- 1 1 1 WALL 'I HEI(-,'YIT pE-171&-A 3/8" Minimum PRODUCT RENEWED as complying with the Florida Building Code NOA-No. 17-0406.06 Expiration Da 05/01/2022 SEF DETAIL A Metal C-stud HardieSoffi* & Cemsoffi* materials are nonasbestos fiber -cement products tested in accordance with ASTM C I 18E Grade 11, Type A and meeting the requirements of the Florida Building Code. Width Length Thickness 4' 81 %" DESIGN PRESSURE RATINGBy_ Miami-Dr(dV'Product Control Cemsofi# t Installation Design Pressure Metal Studs -55 fi j 1 0 1- 7Z Nails at 6" O.C. (typ.) PRODuct' REVISED 10 vomplywz with aw noridA 'N' a wvoyb* with the Fk9J6 Building CoftgeDistanceDRUMCA -At A ..psi too 121 Avm"000 Nat F-*n ir,11-2017 q ATE 0,c Li,AR)ZtE5tM FEI1-PANr--.LJRS-TALJ-A IQtLQE TAIQ$ 01VA L V--, toll$ P All Installation shall be done in conformance with this Notice of Acceptan&,"ViYMAnufacturer`s installation recommendatlons, and the applicable sections of the Florida Building Code, Soffit fastener, as 9 Metal studs where HardieSoffit, Camsoffit will be installed shall be designed by an Engineer or described in Note I Architect per the Florida Building Code and the requirements of this N.O.A. The soft shall be installed over minimum 20ga, Nominal 3-5113" X 1-518" Metal C-studs Spaced a maximum of 16" O.C. HardieSofflit, Cernsoffit A (Note 1] The soffit fastener shall be a minimum No. 8-18. 0,315" head diameter X 1-1/4' long* ribbed bugle head screw (*or Screw shall have at least 3 full threads penetrating metal framing); the fasteners shall be spaced at 6" O.C. at panel edges and intermediate Studs,, the fasteners shall be driven into metal studs located at 16" O.C. Fasteners shall have a minimum edge distance of 3/8" and a minimum clearance of 2" from comers. W HARDIESOFFIT, CEMSOFFIT PANEL 0000 Tt@ = INSTALLATION DETAILS METAL STUD CONSTRUCTION 20ga, 3-5/8" 1 -5/8" Metal C-stud The wall and soffit frames are to be designed by the Architect or Engineer of Record in compliance with the Florida Building Code. Creator I-. Gonzales James Hardie Building Products, Inc. 11 0901 Elm Avenue Fontana, CA 92337 SIZE FSCM NO PW VAG NO A L-PLK-,';OFF 112"= 11--0" 1 Date: 4/24/2013 191-EET 11 OF 12 RM 16.001n Cladding Framing 6.001n. pRODUC-r REVISED PRODUCT RENEWED " tevoying Y'o ft -viatiku m0ouct RoAsw as complying with the Florida 960ding cc** Ivm'oy" witb dw florias Building Code A ?ba-, frLMIC Dmq codc NOA-No. 17-0406.06 Expiration 05/01/2022 By Miami-DAd Product Control 401, NOMINAL 20 GAUG3F 3-5/8" X 1-5/6'STEEL STUDS 16" O.C. o STUDS, PROVISIONS FOR DIAPHRAGM ACTION AND GRAVITY LOAD AREFASTENEDWITH518"WAFER HEAD SCREWS (2 PER TOP FOR METAL AND WOO AND BOTTOM CONNECTION) NOT PART OF THIS APPROVAL (MUST PROVIDE ALTERNATE PROVISIONS FOR THESE LOADS) THE WALL AND SOFFIT FRAMES ARE TO BE DESIGNED BY THE ARCHITECT OR ENGINEER OF RECORD IN COMPLIANCE WITH THE FLORIDA BUILDING CODE CLAD NA 4 HARDIESOFFIT, CEMSOFFIT PANEL THE SOFFIT IS FASTENED WITH NO. 8-18,0.315' HEAD INSTALLATION DETAILS METAL STUD CONSTRUCTION DIAM5TER X 1-114' LONG CORROSION RESISTANT RIBBED BUGLE HEAD SCREWS {SCREW SHALL HAVE AT LEAST James Hardie Building Products, Inc. FULL THREADS PENETRATING THE METAL FRAMING), PLACE 10901 Elm Avenue SCREWS 6" O.C. AT PANEL EDGES AND INTERMEDIATE Fontana, CA 92337 STUDS SIZE FSG DWG NO PE hone: 90:9-356-6300 Fax 900-PNL_P-PLK-SOFFA27-0634 Creator. E. Gonzales 1SMS Date: 4124120I3TSHUT 12 Or 12 PROJECT RIO-2689-17 ENGINEERING EVALUATION REPORT FOR ATTACHING JAMES HARDIE0 BRAND FIBER -CEMENT PANELS TO WOOD FURRING SOLUTIONS JAMES HARDIE BUILDING PRODUCTS, INC. 10901 ELM AVENUE FONTANA, CA 92337 TABLE OF CONTENTS PAGE COVER PAGE 1 EVALUATION SUBJECT 2 EVALUATION SCOPE 2 EVALUATION PURPOSE 2 REFERENCE REPORTS 2 TEST RESULTS 2 TABLE 1A, RESULTS OF TRANSVERSE LOAD TESTING 2 TABLE 1 B, ANALYSIS OF ALLOWABLE LOAD FOR #8 SCREW AT 10" O.C. 2 JUSTIFICATION OF USING THE RESULTS ON LIGHT GAUGE STEEL FRAMING 2 DESIGN WIND LOAD PROCEDURES 3 TABLE 2, COEFFICIENTS AND CONSTANTS USED IN DETERMINING V AND p 4 TABLE 3, ALLOWABLE STRESS DESIGN C&C PRESSURES EXPOSURE B 4 TABLE 4, ALLOWABLE STRESS DESIGN C&C PRESSURES EXPOSURE C 4 TABLE 5, ALLOWABLE STRESS DESIGN C&C PRESSURES EXPOSURE D 4 TABLE 6, ALLOWABLE WIND SPEED (MPH) FOR HARDIEPANEL SIDING 5-6 AS PRODUCT EVALUATOR, THE UNDERSIGNED CERTIFIES THAT THE LISTED PRODUCTS ARE IN COMPLIANCE WITH THE REQUIREMENTS OF THE ASCE 7-10, THE 2017 FLORIDA BUILDING CODE, AND THE 2015 INTERNATIONAL BUILDING CODE, PREPARED BY: RONALD 1. OGAWA & ASSOCIATES, INC. 16835 ALGONQUIN STREET #443 HUNTINGTON BEACH, CA 92649 714-292-2602 714-847-4595 FAX RONALD 1. OGAWA ASSOCIATES, INC. 16835 ALGONQUIN STREET #443 HUNTINGTON REACH, CA 92649 r) 714-292-2602; (F) 714-847-4595 PROJECT: RIO-2689-17 EVALUATION SUBJECT HarchePaneW Siding James Hardie Product Trade Names covered in this evaluation: HardiePanele Siding, Cempane[0 Siding, PrevailTM Panel Siding EVALUATION SCOPE: ASCF 7-10 2017 Florida Building Code 2015 International Building Code 2015 International Residential Code JAMES HARDIE BUILDING PRODUCTS, INC. 1-888-542-7343 into tdjamesharifie.com EVALUATION PURPOSE: This analysis is to determine the maximum design 3-second gust wind speed to be resisted by an assembly of HardiePanel (Cempanel, Prevail Panel) siding fastened to wood fumngS on either wood or metal framing with nails or screws. REFERENCE REPORTS: 1. Interiek Report 102024363COO-001A. Transverse load test on HardiePanal. TEST RESULTS: Table Ia. Results of Transverse Load Testing Frame Fastener Ultimate Allowable Test Thickness Width Sparing Spacing Fastener Type Load Design Load2 Report Number Agency in.) in.) Frame Tyee' on.) in,) and Dimensions PSF) PSF) Failure Mode 102024363COQ-00IA Intellek 0,3125 48 2X4 wood stud, 3/4" thick by 16 6 No. 8 X 1.25" long X 0.323' HD 1 60.7 53,15 pull through /fracture3.5` wide SPF tuning ribbed bugle head screws 102024363COO-001A interlek 0,3125 48 2X4 wood stud, 3/4' thick by 16 8 No. 8 X 1.25' long X 0,323'HD 131.4 43.8 pull through 3 $' wide SPF furring ribbed bugle head screws 102024363COO-001A Intertek 0.3125 48 2X4 wood stud, 3/4'thtck by 16 12 No. 8 X 1.25' long X 0.323'HD 106"! 354 pull through 35' wide SPF furring I ribbed bugle head screws I I 102D24363COQ.001A Inleriek 0.3125 48 2X4 wood stud, 3/4' thick by 16 6 0.090" shank X 0.215" HD x 1.5" 147,6 49.2 pull through /fracture3.5'w,de SPF furring long ring shank nail 102024363COQ-00IA Interlek 0,3125 48 2X4 wood stud, 3/4" thick by 24 8 No. 8 X 1.25" long X 0.323' HD 82.7 27.6 pull through /fracture 3.5" wide SPF furring ribbed bugle head screws 1. All fasteners were installed on furring without penetration into the warning members, 2, Allowable load is determined from ultimate load divided by a factor of safety Of 3. 3, HarifieParel Siding complies with ASTM Cl 186, Standard Specificatton for Grade 11, Type A Non -asbestos Fiber -Cement Fiat Sheets. Table Ib. Analysis of Allowable Load for #8 Screw at 10" O.C. 8 Screw Spacing Fastener SEacing (in.) 8 12 10 Frame Roca in. 16 16 16 Fastener Tributary area (ft') 0,89 1.33 1,11 Allowable load (ldsf) 43;8 35A 38.8 Individual fastener load 6b.) 38,9 47,2 43T The fastener load for #8 screw at 10" O.C. was calculated as the average a the test results for 8" and 12" O.C. The allowable load for #8 screw at the spacing of 10" O.C. into fuming can be calculated by interpolating the results of same fastener at 8" and 12" O.C. , since both tests had same failure mode of fastener pull through from the panels. As shown in the table, the allowable load for #8 screws installed at 10" O.C. to wood furring is 38,8 psf, Justification of Using the Results on Light Gauge Steel Framing In the subject configurations, all fasteners were attached to furring only, so whether the fuming is attached to wood or steel framing does not affect panels' transverse load capacdy. It's the project engineer's responsibility to ensure the furring attachment and framing memebers to have sufficient load capacities, tills' s. RONALD I. OGAWA ASSOCIATES, INC, 16835 ALGONQUIN STREET #443 HUNTINGTON BEACH, CA 92649 T) 714-292-2602; (F) 714-m847-4595 PROJECT: RIO-2689-17 JAMES HARDIE BUILDING PRODUCTS, INC. 1-888-542-7343 info@jameshardie.com DESIGN WIND LOAD PROCEDURES: Fiber -cement siding transverse load capacity (wind load capacity) is determined via compliance testing to transverse load national last standards, Via the transverse loan testing an allowable design load is determined based on a factor of safety of 3 applied to the ultimate test load. Equation 1, q,=0.0Q256*K,*K,,*K,V' (ref ASCE 7-10 equation 30.3-1) q, velocity pressure a, height z K, velocity pressure exposure coefficient evaluated at height z Kv topographic factor Equation 2, K,, wind directionality, factor V basic wind speed (3-second gust MPH) as determined from 2016 IBC Figures (2), or (3), ASCE 7.10 Figures 26.5-1 A, 8, or C V=V, (ref 2015 JBC Section 1602. I definitions) Vx, , ultimate design wind speeds (3-second gust MPH) determined from 2015 IBC Figures 1609.3(1), (2), or (3); ASCE 7-10 Figures 26.5-1A, 8, or C Equation 3, p=q,'(GC,,-GCp,) (ref ASCE 7-10 equation 30.6-1) GC_ product of external pressure coefficient and gust -effect factor GCp; product of internal pressure coefficient and gust -effect factor p design pressure (P$F) for siding (allowable desgn load for siding) To determine design pressure, substitute q. into Equation 3, Equation 4, p=0.00256K,'K,'K,-V.-(GCrGC,,) Allowable Stress Design, ASCE 7-10 Section 2.4. 1, load combination 7 Equation 5, 0.5D - 0.6w (ref ASCE 7-10 section 2.4.1, load combination 7) D , dead load W . wind load To determine the Allowable Stress Design Pressure, apply the load factor for IN (wind) from Equation 4 to p (design pressure) determined from equation 4 Equation 6, p— = 0 slpi Equation 7, p_ = 0.6'[0,00256*K,-K„-K,-V,'-(GC,-GC,)I Equation 7 is used to populate Table 3, 4, and 5. To determine the allowable ultimate basic wind speed for Hardie Siding in Table 6, solve Equation 7 for V_ Equation 8, V,,, = (p,10.6*0,00256*K,*Kp*K,*(GC,-GC,,))"' Applicable to methods specified in Exceptions I through 3 of 2015 IBC Seaton 1609 1 1_ to determine the allowable nominal design wind speed (Vasch forl-fardie Siding in Table 6, apply the conversion formula below. Equation 9, V— = V. - (0 6)" (,*at 2015 IRC Section 1609.3 1) V,,,, Nominal design wind speed (3-second gust mph) (ref 2015 IBC Section 1602. 1) RONALD I. OGAWA ASSOCIATES, INC. 16835 ALGONQUIN STREET #443 HUNTINGTON BEACH, CA 92649 T) 714-292-2602, (F) 714-8474595 PROJECT: RIO-2689-17 Table 2, Coefficients and Constants used in Determining V and p, K W.11 Zane 5 Height (it) EKP B Exp C Fxp D K, 3c, GC, 0-15 0,7 0,85 t03 hs60 1 85 1'4 0,18 20 03 0,9 108 1 0.85 1A 0.18 25 0.7 0.94 7 12 1 0,85 1A_ 0.18 30 0,7 0,98 1.16 1 0.85 1A 0,18 35 0.73 1,01 1.19 1 0.85 1,4_ 0,18 40 0,76 1.04 1.22 1 0.85 1A 018 45 0.7155 1.065 1.245 0.85 1A 0.18 110 0.81 1.09 1.27 1 0,85 1A 0,18I - 535 iK f 1.11 1, 1 N 1A 0.18, E0.85 1.13 0, 1A 0.18 100 1 h,60 1 0.85 1.8 0.18 JAMES HARDIE BUILDING PRODUCTS, INC. 1-888-542-7343 info@jameshardie,com Table 3, Allowable Stress Design - Component and Cladding (C&C) Pressures (PSF) to be Resisted at Various Wind Speeds - Wind Exposure Category B, no SEfed (3-second 2ust) 100 105 110 115 120 130_ 140_ 150 160 170 180 190 200 210 Height (it) B a 8 Ei 6 8 8 8 B B B 8 B B 0.15 14.4 15.9 17,5 19.1 20,8 24.4 28.3 32.5 37.0 41.7 46.8 52,1 57.8 633 20 14.4 15.9 17.5 19.1 120.8 24A 2,83 32,5 37,0 41,7 46,8 52,1 57.8 63.7 25 14A 15.9 17.5 19.1 20.8 24.4 2& 32.5 37.0 41.7 46.8 52.1 57.8 633 30 14.4 15.9 17.5 19A 20.8 24A 28,3 32.5 37.0 41.7 46.8 52.1 57,8 53,7 35 15.1 16.6 18.2 19.9 21,7 25A 29,5 33.9 386 43.5 48S 54A 60,2 66.4 40 15.7 17.3 19.0 20.7 Z6 26.5 307 35.3 401 45,3 50.8 56.6 62.7 69.1 45 16.2 17,9 19.6 21.4 23.3 27.4 31.7 36.4 41,5 46.8 52.5 58.5 64.8 1A 50 16.7 18.4 20,2 221 28.2 32.7 37,6 -T Q.8 j -54.1 1 -60.3 1 -66.8 73.7 55 20 22.5 243 38.5 418 49-6 55.5 61.8 6&5 75.5 60 17 21 , 29.6 34.4 49 5 44.9 7 56.8 63,3 70,1 77.3 100 25.6 28.2 31,0 318 36,9 43.3 5012 12.9 Table 4, Allowable Stress Design - Component and Cladding (C&C) Pressures (PSF) to be Resisted at Various Wind Speeds - Wind Exposure Category C, nd Speed (3-second 2ust) 100 105 110 115 120 130 140 150 160 170 180 190 1 200 210 Height (It) C C C C C C C C C C C C C C 0-15 17.5 19.3 21,2 23.2 25,2 29,6 34A 39,5 44.9 50.7 56.8 ea3 70.1 7-7.3 20 18,6 20.5 22.5 124.6 26,7 31.4 36A 41,8 47.5 53,7 60.2 67,0 74.3 81,9 25 19.4 21A 23.5 25.6 27.9 32.8 3&0 43.6 49.6 56,0 62.8 70.0 77.6 85,5 30 20.2 22.3 24,5 26,7 291 34.2 39.6 45.5 51,8 58,4 66.5 73,0 80.9 89.2 35 20.8 23,0 25.2 27,6 30,0 35.2 40,8 46.9 53.3 60,2 67.5 75.2 83.3 91.9 40 21.6 2Z,7 726-0 28A W 9 36,3 4ZO 48,3 54'9 15 Gq,5 774 85.8-- 45 22-0 24,2 26.6 29.1 31.6 37.1 431 49.4 56.2 63'5 71.2 93 87,9 96,9 50 22,5 24,6 27.2 29,7 324 38.0 44.7 50,6 57.6 66.0 72.9 81 .2 89.9 99.2 55 273 30.3 58.6 66.2 74.2 101'D 60 23.3 25.7 T- 8.2 30.8 J3.6 39.4 4 1.t b:4,4 593 7-67 -4 7777- 84.1 93.2 1 2. 410032.6 35.9 39A 43.1 6,9 55.0 63,8 r- 73.3 93-4-7 94-1 7775-5 117,6 130.3 143,6 Table 6, Allowable Stress Design - Component and Cladding (C&C) Pressures (PSF) to be Resisted at Various Wind Speeds - Wind Exposure Category D, rid Speed (3-second gust) 100 105 110 115 1 120 130 140 150 160 170 180 190 200 210 Height (ft) D 0 D D D D D D D D D 0 D D 0.15 21.2 23.4 25.7 281 30.6 35.9 41,6 47.8 54.4 61,4 68,8 76,7 85.0 93,7 20 223 24k 27.0 29.5 32.1 37.7 431 50'1 57,0 64.4 72.2 80A 89.1 98.2 25 23.1 25.5 28.0 30.6 33.3 39.0 453 52,0 59.1 66.8 74.9 83A 92A 1019 30 23,9 25.4 29.0 31.6 34.5 40,4 46.9 53,8 61,3 69,2 77.5 86A 95Y 105.5 35 24,5 27.1 29.7 32.5 35.3 41.5 48,1 55.2 62,8 70.9 79,5 88.6 98.2 1082 40 25.2 27.7 30.5 33.3 36.2 42.5 49,3 56.6 64.4 72.7 81.5 90.9 100.7 111.0 45 253 28.3 37.0 43.4 50.3 57.8 65.7 74.2 83.2 92.7 102.7 113.3 50 26.2 28,9 31.7 34.6 37.7 44.3 51.3 5&9 67A 75.7 84.9 94.6 104.8 115.5 55 26.6a.-29.8 2-9,35 32,2 2 38'3 45,0 52,2 59.9 681 76.9 116-2; 117.4 60 j-2 9. 3 39 1 45 TO _8 ff-2. R 1 F 7 11 100 37.0 40.B 443 4&9 1 .53 2 625 72 163,0 Tables 3, 4, and 5 are based -on ASOE 7-10 and consistent with the 2015 IBC, 2015 IRC 401 # lt I / 11A " v'f'w" , it ' . . ... ..... RONALD 1. OGAWA ASSOCIATES, INC. 16835 ALGONQUIN STREET #443 HUNTINGTON BEACH, CA 92649 T) 714-292-2602: (F) 714-6474595 PROJECT: RIO-2689-17 JAMES HARDIE BUILDING PRODUCTS, INC. 1-888-542-7343 infoQjameshardie. corm Table 6, Allowable Wind Speed (mph) for HardiePanel Siding (Analytical Method in ASCE 7-10 Chapter 30 C&C Part 1 and Part 3)6 At Allowable, NominalAllowable, ultimate Design Wind, Speed, Design OAnd, asV. I V..' " Applicable to methods specified in 12015 18C, 2017 F8Cj Section Wl, 1.1. as determined b 2015 IBC, 2017 FBCj Fig.- 1609.3(1), (2), o, 3), find exposure cateqor Applicable to methods specified in Exceptions I through a of 12015 IBC, 2017 F8Cj section 1609j' l, exposure catectofv Coefficients used in Table 6 calculations Product Minimum Thickness in.) Wdth in) Fastener T TypeFastener Spacing Frame Type Stud Spacing in.) Building Height' s It.) 8 C 0 a C I D Allowable Design Load psf) Exp 8 Exp C Expo Kn K, GC, GC, i HandieParielt 5/16 48 No. 8 X 1, 25- long X 0,323" HD ribbed bugle head screws 6" O.C. into furring only 2X4 wood or 20 go. steel framing, 3/4" thick by 3.6' wide wood furring 16 0. 15 193 175 159 149 135 123 53.6 0,70 0.85 1.03 hs60 I 0.85 14 0.181 20 193 170 156 149 112 120 53.6 0.70 0.90 1-08 1 0.t 1.4 018 26 193 166 152 149 129 118 53.6 0,70 UA 1.12 1 O.E A4 0.18 30 193 163 150 149 126 116 53.6 0.70 0.98 0.8 0.85 0.8 4 0,18 135160114814612411453.6 0,73 1.01 1, 16 1. 19 1 0,851 1A OA8 40 185 158 146 143 122 113 53.6 0,76 1.04 1,22 1 1,4 0.18 45 172 150 140 133 116 108 53.6 0.88 1.15 1.33 1 0.85 1,4 111 50 179 154 143 139 120 111 53.6 0,81 1.09 1,27 1 KOJ815O,aS 1.4 0.18 55 177 153 142 137 119 110 53,6 0,83 1,11 1.29 1 0.85 1A 0.18 60 175 7 52 41 135 117 109 53.6 0.85 1.13 1.31 1 A 0.18 100 145 128 120 112 99 93 53,15 0,99 l,26 1,43 h>60 1 0,851 Aa 0.18 HarchePanelg 5116 1 48 No. 8 X 1. 25- long X 0.323" HD ribbed bugle head screws 1 811 0, C, into furring only 2X4 wood or 20 ga. steel framing, 314" thick by 3.6' wide wood furring 7A 16 0- 15 174 168 144 135 122 ill 43,8 0,70 0,85 1.03 hs60 I 0,85 4,4 018 20 174 154 140 135 119 109 43.8 0.70 0.90 1,08 1 0.85 1.4 0,18 25 174 150 138 135 116 107 43.8 0.70 0.94 1.12 1 L85 1,4 018 30 174 147 135 135 114 105 43.8 0.70 0.98 1,16 1 0.85 1,4 0,18 35 171 145 134 132 112 103 43a 0,73 1.01 7- 19 1 0.85-1.4 0.18 40 167 143 132 129 Ill 102 43.8 0,76 1.04 T22 1 0.86 lA 0.18' 45 164 141 131 127 1 101 43,8 C.79 1.07 1.25 1 0.85 1.4 013 50 162 140 129 125 106 loo 43.8 0,81 1.09 72-7 1 0.85 14 0A8 55 160 138 128 124 107 99 43.8 0.83 1.11 1,29 1 ixed 1, 0,18 60 1158 137 127 122 106 99 43.8 6.85 1.13 1.31 10.851 14 0.18 100 131 116 101 90 0,99 1.26 141 h160 i M 1,8 Ll I HardiePanelO 5/16 48 No. 8 X 1, 25' long X 0.323' HD ribbed bugle head screws 10" O.C. into turring only 2X4 wood or 20 go, steel framing, 3/4' thick by 3.5' wide wood tumng 16 0- 16 164 149 135 127 11-5- 105-- 38.8-- 0.70 0.85 1,03 hs60 1 0L85 14 0,18 20 164 145 132 127 112 102 38.8 030 0.90 1.08 0.05 1,4 018 25 164 141 130 127 lio 101) 38.8 0.70 0.94 1,12 L 1 0.85-1.4 0.18 30 164 139 127 127 107 99 38.8 0,70 0.98 1,16 1 Tss - 71.4 0.18 35 161 136 126 124 106 97 38.8 0.73 1.01 1-19 AA 0,18 40 157 134 124 122 104 96 38,8 0.76 1.04 1,22 1. 2.65 1 0.85 1A 0.18 45 155 133 123 120 103 95 38.8 0,79 1.07 1,26 1 8, 7a 0.18 50 152 131 122 118 102 94 38.8 G.Bl 1,09 1,27 1 0,85 14 0,18 55 151 130 121 117 101 94 38,8 0-83 1.11 1,29 L I j 0,851 1A 0,18 60 149 129 120 115 100 93 Xa 0ia5- 1,13 5.31 1 T0.85T 1.4 0.18 100 123 95 38.8 0,99 126 1.43 h>60 1 10.851 1.8 0.18 HarchePanelb 5/10 48 No. 8 X 1. 25- long X 0.323' HD ribbed bugle head screws 12" C,C. into furring only 2X4 wood or 20 ga. steel framing, 3W thick by 3.5' wide wood furring 16 0- 15 157 142 129 121 110 100 35.4 0.70 0,85 1.03 hs60 1 0,85 1,4 018 20 157 138 126 121 107 98 35.4 0,70 0.90 1.08 1 0,85 1,4 0.18 25 157 135 124 121 105 96 35A 0,70 0,94 1.12 1 0.85_ AA 0.18 30 157 132 122 121 101 1 94 35,4 0,70 0.98 116 1 0,85 1,4 0.181 35 163 130 120 119 101 93 35A 0.73 1.01 1,19 1 0.85 1.4 0,18 40 150 128 119 116 100 92 35A 0.76 1.D4 1.22 1 0.85 1,4 0,18 45 148 127 117 115 98 91 35.4 O 79 JF, 1.07 1.25 1 0.85 1.4 OJ8 50 146 125 116 113 97 90 35A Lel 1,09 1.27 1 0,85 1.4 0,18 65 144 124 115 ill 96 89 35A 0-83 1.11 1,29 1 0a$ 1A CAI) 611 142 121 114 111) 116 89 35.4 0.85 1.13 1.31 1 10.85 1A 0.18 100 1 118 191 143 h.601 I pe 5. 0. -1e oflifff1l, f'o" -1 AMA CC Lw P 4-,, FLO Slo RONALD 1. OGAWA ASSOCIATES, INC 16835 ALGONQUIN STREET #443 HUNTINGTON BEACH, CA 92649 T) 714-292-2602: IF) 714-847-4595 PROJECT: RIO-2689-17 JAMES HARDIE BUILDING PRODUCTS, INC. 1-888-542-7343 info@jameshardie.com Allowable, Ultimate Allowable, Nominal Design V'And, Speed, Design VIAnd, Speed, V. 3s' v..*,r. 3-second gust mph) 3-second gust mph) Alophoalbie to methods specified to (2015 IBC, Applicable to methods 2017 Faq S.ct.n speafi.d . F-pla.ns I 1609,11, as determined by through 3 of (2015 IBC, 12015 18C, 2017 FBC) 2017 FBCj Section Figures or 1609.11. 3). 1 1 Coefficients used in table 6 calculations for V. Wind exposure category Wind exposure category Stdmg K, Product Minimum Thickness In,) Width in.) Fastener Type Fastener Spacing Spacing Frame Type Stud Spacing Building Height'.1 111) 6 C1 D1 B D Allowable Design Load pst) Exp 8 ExpC Exp D K Its GC' GC 0-15 138 1 125 114 1()7 97 BB 27,6 0,70 0,85_ 1.03 hS60 1 0.85 1.4 0.18 20 138 122 ill 107 94 86 27.6 0,70 0.90 1,08 1 0.85 1.4 0.18 HardieParielfin 5116 48 No. 8 X 1,25' long X D.323' HD ribbed bugle head screws 8" O.C. into furring only 2X4 wood or 20 ga. steel framing, 314' thick, by 3.5` wide wood furring 24 25 138 119 107 92 27,15 0.70 0.94 1,12 1 0,85 14 0.18 30 138 117 107 91 27.6 0.70 0.98 1.16 1 0.85 I'A 018 35 135 116 105 89 27.6 0,73 1 101 1 1,19 1 1,4 0.18 40 133 113 103 88 27.6 0,76 1,04 1.22 1 0. 85 0. 85 1A 0,18 45 131 112 101 87 27.6 0,79 1.07 1.25 1 0,85 1A 0.18 ill 100 86 27.6 0.81 1.09 1.27 1 0.85 1.4 0.16 55 127 98 27,6 0,83 i'll L.79 r-1-0.85 1'4 0.113 60 125 9'7 27.6 0,85 113 1.31 F FC1 85 1.4 77 8 100 27. 6 0.99 1.26 1.43 h>60 1 0.85 1.8 OAS 0-15 185 168 152 143 130 118 49-2 0,70 0.85 1.03 hS80 1 0,85 14 0,18 20 185 163 149 143 126 115 49,2 0,70 0.90 1,08 1 TV 74 0,16 HardieParielt 5/ 16 48 0.090" shank X 0.215' HD x 1, 5* long prig shank nail 6' Q. C. into furring only 2X4 wood or 20 ga. steel framing, 314' thick by 3,5" wide wood furring 'ix 16 25 185 159 146 143 123 113 49.2 0,70 0,94 1,12 1 1 85 1.4 olil 30 185 156 143 143 121 ill 49,2-- 0.700.98 1,16 1 T -B5 AA 018 35 181 154 142 140 119 110 49,2 0,73 1,01 t.19 1 5 1 4 0.18 40 177 151 140 137 117 108 49.2 0,76 1.04 1.22 1 4 O,le 45 174 150 138 135 116 107 49.2 0,79 1.07 1,25 1 fl.&5 1 1.4 o'le 50 172 137 9.2 0.61 1.09 1.27 1 0.85 1. 0.18 5=5= 1 70 1 M 136 131 1.5 9-.2 29 1 0.85 1A 018 60 168 146 135 130 113 105 1 49.2 0.85 fl 1.311 0.85 1.4 0,18 100 139 123 115 107 95 89 1 49,2 0,99 1. Furring attachment to Strochi I framing members or allemativefu ngwdl)i Shall be designed by an engineer. 2. Building height - mean mot height (in (eet) of a building, except that taus height shall be used for met angle 0 less than or equal to 10' (2-12 roof slope). 3. V„, = ultimate design wind speed, 4. V., = nominal design wind speed 5, Linear interpolation of building height (S 60 ft) and wend speed is perm0led, 6, Wind speed design assumptions per Analytical Method in ASCE 7,10 Chapter 30 C&C Part I and Part a: K -I, K,-0.85, GC,,1.4 (hs60), GC,®1'8 (h>60), GCW-DA& 7, Wood furring shall be preservative treated per AWPA, 8, Wood fumng shall be specific grtvily, of 0.42 or greater per AFPA/NDS, or wood Structural panel, conforming to DOC PS -I a, DOC PS-2 or And PRP-108. LIMITATIONS OF USE: 1) In High Velocity Hurricane Zones (HVHZ) install per Miami -Dade County Florida, NOA 17-0406.06 till C17 4 FLUR ssio w PROJECT RIO-2686-17 ENGINEERING EVALUATION REPORT FOR ATTACHING JAMES HARDIE(b BRAND FIBER -CEMENT PANELS TO WOOD AND METAL FRAMED WALLS WITH VARIOUS FASTENERS JAMES HARDIE BUILDING PRODUCTS, INC. 10901 ELM AVENUE FONTANA, CA 92337 TABLE OF CONTENTS PAGE COVER PAGE 1 EVALUATION SUBJECT 2 EVALUATION SCOPE 2 EVALUATION PURPOSE 2 REFERENCE REPORTS 2 TEST RESULTS 3 TABLE 1A, RESULTS OF TRANSVERSE LOAD TESTING 3 TABLE 16, SHEAR VALUES 3 DESIGN WIND LOAD PROCEDURES 4 TABLE 2, COEFFICIENTS AND CONSTANTS USED IN DETERMINING V AND p 4 TABLE 3, ALLOWABLE STRESS DESIGN C&C PRESSURES EXPOSURE B 5 TABLE 4, ALLOWABLE STRESS DESIGN C&C PRESSURES EXPOSURE C 5 TABLE 5, ALLOWABLE STRESS DESIGN C&C PRESSURES EXPOSURE D 5 TABLE 6, ALLOWABLE WIND SPEED (MPH) FOR HARDIEPANEL SIDING 6-7 LIMITATIONS OF USE 7 AS PRODUCT EVALUATOR, THE UNDERSIGNED CERTIFIES THAT THE LISTED PRODUCTS ARE IN COMPLIANCE WITH THE REQUIREMENTS OF THE ASCE 7-10, THE 2017 FLORIDA BUILDING CODE, AND THE 2015 INTERNATIONAL BUILDING CODE. PREPARED BY: RONALD 1. OGAWA & ASSOCIATES, INC. 16835 ALGONQUIN STREET #443 HUNTINGTON BEACH, CA 92649 714-292-2602 714-847-4595 FAX RONALD 1, OGAWA ASSOCIATES, INC, 16835 ALGONQUIN STREET #443 HUNTINGTON BEACH, CA 92649 714-292-2602 714-847-4595 FAX PROJECT. RIO-2686-17 JAMES HARDIE BUILDING PRODUCTS, INC. 1-888-542-7343 info@jameshardie.com EVALUATION SUBJECT HardieParielt Siding James Hardie Product Trade Names covered in this evaluation: HardiePanelS Siding, CemparrelS Siding, PrevailTM Panel Siding EVALUATION SCOPE: ASCE 7-10 2017 Florida Budding Code 2015 International Building Codee EVALUATION PURPOSE: This analysis is to determine the maximum design 3-second gust wind speed to be resisted by an assembly of HardiePanel (Gempanel, Prevail Panel) siding fastened to wood or metal framing with nails or screws, REFERENCE REPORTS: 1. Intertek Report 3067913 (ASTM Cl 186) Material properties HardiePanel Siding 2, Ramtech Laboratories Report IC-1 270-q4 (ASTM E330) Transverse Load Test, 5116" Thick by 48 inch wide HardiePanel Siding installed on 2X4 Hem -Fir wood studs spaced at 16 inches on center with a 6d common galvanized nail 3. Ramtech Laboratories Report IC-1271-94 (ASTM E330) Transverse Load Test, 5116" Thick by 48 inch wide HardiePanel Siding installed on 2X4 Hem -Fir woad studs spaced at 24 inches on renter with a 6d common galvanized nail 4, Ramtech Laboratories, Inc. Report 10868-9711475 (ASTM E330) Transverse Load Test, 5/16' Thick by 48 inch wde HardiePanel Siding installed on 2X4 Group III SG=0.36 Wood studs spaced at 16 inches on center with a 4d, 0.091 inch shank by 0.225 inch head diameter by 1.5 inch long ring shank nail 5. Ramtech Laboratories, Report IC-1054-89 (ASTM E330) Transverse Load Test, 1/4" Thick by 48 inch wide HardiePanel Siding installed on 20gauge Metal studs spaced at 16 inches on center with a No 8 X 1 in, long X 0,323 in head diameter ribbed bugle head screw 6. Ramtech I_SbOfatrideS, Report IC-1 055-89 (ASTM E330) Transverse Load Test 114" Thick by 48 inch Woe HardiePanel Siding installed on 209auge Metal studs spaced at 24 inches an center with a No 8 X 1 in, long X 0.323 in head diameter ribbed bugle head screw 7. Ramtech Laboratories, Report 11 149-9811554d (ASTM E330) Transverse Load Test, 114" Thick by 48 inch wide HardiePanel Siding installed on 20gauge Metal studs spared at 16 and 24 inches on center with a ET&F 0.100 in. knurled shank X 1.5 in. long X 0,25 in, head diameter pin fastener 8. Ramtech Laboratories Report IC-1273-94 (ASTM E72) Racking Shear Test, 5/16" Thick by 48 inch wide HardiePanel Siding installed on 2X4 Hem -Fir wood studs spaced at 16 inches on center with a 6d common galvanized nail 9. Ramtech Laboratories Report IC-1274-94 (ASTM E72) Racking Shear Test, 5116" Thick by 48 inch wide HardiePanel Siding installed on 2X4 Hem -Fir mod studs spaced at 24 inches on center wth a 6d common galvanized nail 10. Ramtech Laboratories, Inc. Report 10868-97/1475 (ASTM E72) Racking Shear Test, 5/16" Thick by 48 Inch wide HardiePanel Siding installed on 2X4 Group III SG=0.36 wood studs spaced at 16 inches an center with a 4d, 0.091 inch shank by 0.225 inch head diameter by 1.5 inch long ring shank nail 11. Ramtech Laboratories Report IC-1 057-89 (ASTM E72) Racking Shear Test, 5/16" Thick by 48 inch wide HardiePanel Siding installed on 2X4 Hem -Fir wood studs spaced at 16 and 24 inches on center with a No 8 X I in. long X 0.323 in head diameter ribbed bugle head screw 12. Ramtech Laboratories Report 11284-9911580 (ASTM E72) Racking Shear Test, 5/16" Thick by 48 inch wide HardiePanel Siding installed on 2X4 Hem-Firwoodstuds spaced at 16 and 24 inches on center with a ET& F 0.100 in, knurled shank X 1.5 in. long X 0.25 in. head diameter pin fastener IIIII; to 111 0 . G A STATE JAMES HARDIE BUILDING PRODUCTS, INC. 1-888-542-7343 info@jameshardie.com TEST RESULTS: Table 1 a, Results of Transverse Load Testing RONALD I. OGAWA ASSOCIATES, INC, 16835 ALGONQUIN STREET #443 HUNTINGTON BEACH, CA 92649 714-292-2602 714-847-4595 FAX PROJECT: RIO-2686-17 IFastener Spacing ( lb., I Allowable Frame Ultimate Design Thickness Width Spacing Perimeter Field Load Load' Report Number Test Agency in in,) Frame Type in.) Supports Supports Fastener Type PSF) PSF) IC-1270-94 Ramtech 0,3125 48 2X4 wood Hem -Fir 16 6 6 6d common 149 49.7 IC-1270-94 Ramtech 0,3125 48 2X4 wood Hem -Fir 16 4 4 6d common 236 78.7 IC-1271-94 Ramtech 0.3125 48 2X4 wood Hem -Fir 24 6 6 6d common 94 31,3 IC-1271-94 Ramtech 0.3125 48 2X4 wood Hem -Fir 24 4 4 6d common 143 47.7 108W9711475 Ramtech 0.125 48 2X4 woo d, SG a 0.36 16 4 8 4d, 0.091 in. shank X 0 in, n 90 30,0 HD X 1,5 in. to 22 orig shank nall Min, No. 20 gauge X 3.625 in. X Min. No 8 X I in. long X 0.323 in IC-1054-89 Ramtech 0.25 48 1.375 in metal stud 16 6 6 head diameter ribbed bugle 169,9 56.6 head screw Min. No, 20 gauge X 5.625 in. X Min. No 8 X I in. long X 0,323 in IC-1055-89 Ramtech 0.25 48 1.375 in metal stud 24 6 6 head diameter fibbed bugle 91.9 30.6 head screw Min. No. 20 gauge X 3,625 in. X ET&F 0A00 in. knurled shank X 11 149-98/1554d Ramtech 0.3125 48 1.376 in metal stud 16 4 8 1.5 in. long X 0,25 in. head 170 56,7 diameter pin fastener Min. No. 20 gauge X 3.625ET&F 0.100 in. knurled11149-9811654d Ramtech 1 0,3125 48 1,375 in metal stud 24 4 8 1.5 in. long X 0.25 in. 33.7 diameter pin fastener 1. Allowable Load is the Ultimate Load divided by a F actor of safety of 3. 2. HardiePanel Siding complies with ASTM C 1186, Standard Specification for Grade 11, Type A Non -asbestos Fiber -Cement Flat Sheets. Table 1 b, Shear Values Allowable Loads In Pounds Per Lineal Foot for Panel Shear Walls' s Fastener Spacing fin I Frame Ultimate Allowable Thickness Width Spacing Perimeter Field Load3 Load' Report Number Test Agency in.) in,) Frame T)Te in.) Supports Supports Fastener T)Te pit) pit) IC-1273-94 Ramtech 0.3125 48 2X4 wood Hem -Fir 16 6 6 6d common 603,8 201.3 IC-1273-94 Ramtech 0.3125 48 2X4 wood Hem -Fir 16 4 4 6d common 698.13 232.9 IC-1274-94 Ramtech 0.3125 48 2X4 wood Hem -Fir 24 6 6 6d common 460.0 153,3 IC-127444 Ramtech 0.3125 48 2X4 wood Hem -Fir 24 4 4 6d Gammon 637.5 212.5 10868-97/1475 Ramtech 0.3125 48 2X4 wood, SG e 0.36 16 4 8 4d, 0.091 in, shank X 0.225 in. 595.4 198.5 HD X 1.5 in. long ring shank nail Min. No. 20 gauge X 3.625 in. X Min No 8 X 1 in. long X 0X3 in IC-1057-89 Ramtech 0L25 48 1,375 in metal stud 16&24 6 6 head diameter ribbed bugle 990,0 123.8 head screw Min. No. 20 gauge X 3.625 in. X ET&F 0,100 in. knurled shank X 1 Rarntech 0,3125 48 1.375 in metal stud 16 4 8 1.5 in. long X 0.25 in, head 1227.0 153A diameter pin fastener Min, No. 20 gauge X 3.625 in. X ET&F 0.100 in, knurled shank X 1128499/1580 Ramtech 0.3125 48 1,375 in metal stud 24 4 8 1.5 in. long X 0.25 in. head 1060.0 1132.5 I I diameter pin fastener 1. All board edges shall be supported by framing. Panels shall be applied with the long dimension either parallel or perpendicular to studs. 2. The maximum height-to4ength ratio for construction in this Table isis 1 3. In the steel framed assemblies the allowable load is based on the average load at 1/8 inch net deflection. G A W4 F Fir K, I Wall Zone 5 Height (ft) Exp 8 Exp C i Exp D K. K,, GC, 7GC 0-15 V 0.85 1,03 h:560 1 0,85 14 0.18 20 0.7 0.9 1.08 1 0.85 1.4 o l 8 25 03 0.94 1.12 1 0,85 1.4 0.18 30 0.7 0.98 1.16 1 0.85 1.4 0.18 35 0,73 1.01 1.19 1 0,85 1,4 g' 40 0.75 1.04 1.22 1 0,85 1.4 0.18 45 0385 1.065 1.245 1 0,85 1.4 0A8 50 0.81 1,09 1.27 1 0.85 1.4 0 * 18 55 0.83 1,11 1.29 1 0.85 0.18a500.85 1.13 1.31 1 0.85 1.4 1.4 018 100 0,99 1.26 1.43 h,60 1 0.85 1.8 0,18 RONALD 1. OGAWA ASSOCIATES, INC. 16835 ALGONQUIN STREET #443 HUNTINGTON BEACH, CA 92649 714-292-2602 714-847-4595 FAX PROJECT: RIO-2686-17 JAMES HARDIE BUILDING PRODUCTS, INC. 1-888-542-7343 info@jameshardie.com DESIGN WIND LOAD PROCEDURES: Fiber -cement siding transverse load capacity (wind load capacity) is determined via compliance testing to transverse load national test standards, Via the transverse load testing an allowable design load is detennined based on a factor of safety of 3 applied to the ultimate test load. Since the allowable design load is based on factor of safety of 3, allowable design loads on fiber -cement siding correlate directly to required design pressures for Allowable Stress Design, and therefore should be used with combination loading equations for Allowable Stress Design (ASD). By using the combination loading equations for Allowable Stress Design (ASID), the tested allowable design loads for fiber -cement siding are aligned with the wind speed requirements in ASCE 7- 10 Figure 26.5-1 A, Figure 26. 5-18, and Figure 26.5-1 C. For this analysis, to calculate the pressures in Tables 3, 4. and 5, the load combination will be in accordance with ASCE 7-10 Section 2.4 combining nominal loads using allowable stress design , load combination 7. Load combination 7 uses a load factor of 0.6 applied to the wind velocity pressure, Equation 1, q,-0.00256*K,*K,*K,*V2 (ref. ASCE 740 equation 30.3-1) q, velocity pressure at height z K, velocity pressure exposure coefficient evaluated at height z K,, topographic factor Ka wind directionality factor V basic wind speed (3-second gust MPH) as determined from (2015 IBC, 2017 FBCJ Figures 1609.3(l), (2), or (3); ASCE 7-10 Figures 26.5- 1A, B, or C Equation 2, V.V,, (ref, 2015 IBC & 2017 F8C Section 1602,1 definitions) Via , ultimate design wind speeds (3-second gust MPH) determined from 12015 18C, 2017 FBC] Figures 1609.3(1), (2), or (3); ASCE 7-10 Figures 26.5- 1 A, 8, or C Equation 3, p=q,*(GC,-GC,J (ref ASCE 7-10 equation 30,6-1) GCv product of external pressure coefficient and gust -effect factor GC, product of internal pressure coefficient and gust -effect factor p design pressure (PSF) for siding (allowable desgn load for siding) To determine design pressure, substitute q, into Equation 3, Equation 4, p=0.00256*K,*K*K,*V,,-(GCaGCS ) Allowable Stress Design, ASCE 7-10 Section 2 4, 1, load combination 7 Equation 5, 0.613 + 0.6W (ref ASCE 7-10 section 2.4, 1, toad combination 7) D dead load W wind load To determine the Allowable Stress Design Pressure, apply the load factor for W (wind) from Equation 4 to p (design pressure) determined from equation 4 Equation 6, P.. , 0.61p) Equation 7, p„, = 0.6*f0.00256-K,-K.-K,'V,,-(GCCGC,)I Equation 7 is used to populate Table 3, 4. and 5 To determine the allowable ultimate basic wind speed for Hardie Siding in Table 6, solve Equation 7 for V., Equation 8, V,,, = (p.,,/0.6*0,00256*K,*K,*K,(GC,-GC„ ))" Applicable to methods specified in Exceptions I through 3 of 12015 18C, 2017 FBC) Section 1609.1.1., to determine the allowable nominal design wind speed (Vasd) for Hardie Siding in Table 6, apply the conversion formula below, Equation 9, V.d = V. - (0.6)" (ref 2015 /8C & 2017 FBC Section 1609,3, 1) V, Nominal design wind speed (3-second gust mph) (fair 2015 IBC & 2017 FBC Sectintj Table 2, Coefficients and Constants -used in Determining V and p, lit to oil A IV CC ST T 01% k, RONALD 1. OGAWA ASSOCIATES, INC, 16835 ALGONQUIN STREET #443 HUNTINGTON BEACH, CA 92649 714-292-2602 714-847-4595 FAX PROJECT: RIO-2686-17 JAMES HARDIE BUILDING PRODUCTS, INC. 1-888-542-7343 info@janieshardie.com Table 3, Allowable Stress Design - Component and Cladding (C&C) Pressures (PSF) to be Resisted at Various Wind Speeds - Wind Exposure Category 8, Wind Speed (3-second 2ust) 100 105 110 115 120 130 1 140 150 160 170 180 190 200 210 Height (ft) 8 B B B B B B 8 8 B 8 B 8 B 0-15 14.4 15.9 17.5 19.1 20.8 24A 28,3 32,5 37,0 41,7 46.8 52.1 57.8 63.7 20 14.4 17.5 19.1 20.8 24.4 28.3 32.5 37.0 413 46.8 52.1 57.8 633 25 14.4 15,9 17.5 19.1_ 20.8 24.4 28.3 32.5 37.0 41.7 46.8 52.1 57.8 63.7 30 14.4 15.9 17.5 19,1 20.8 24.4 28,3 32.5 37,0 41.7 46.8 52.1 57.8 63.7 36 15.1 16.6 18.2 19.9 21 .7 25.4 29,5 33,9 38.6 43.5 48.8 54A 60.2 66.4 40 153 17.3 19.0 20.7 22.6 L_-26.5 303 35.3 40,1 45.3 50.8 56.6 62.7 69.1 45 16.2 17.9 19.6 21 A 23.3 27.4 31.7 36.4 415 46.8 52,5 1 -58.5 64 ,8 71A 50 16,7 I8A 212 A 24.1 28.2 32.7 37.6 4 2.8 48.3 54.1 60,3 66.8 73,7 55 17.1 O 7 1- 2 _2 - 6 24 12 215 16 31.6 38,5 13,8 425 5gl gl 61-1 68.5 75.5 60 17.5 19.3 21.;! 1 -z-e 1 34A 39.5 9 0 7 g 63.3 701 100 25.6 28.2 1 -31.0 1.33 36.91 43,3 1 -50,2 57,6 1 -65.5 74,0 1 -82,9 1 -92.4 102A 1 2=9 Table 4, Allowable Stress Design - Component and Cladding (C&C) Pressures (PSF) to be Resisted at Various Wind Speeds - Wind Exposure Category C, Wind Speed (3-second gust) 100 105 110 1 115 120 130 1 140 ISO 160 170 180 190 1 200 1 210 Height (ft) C C C I C C C I C C C C C C C I C 0-15 17.5 19.3 21,2 1-23.2 25.2 29.6 34A 39.5 049 50.7 56.8 63.3 70.1 77,3 20 18.6 20.5 22.5 24,6 26.7 31.4 36.4 41.8 47.5 63.7 60.2 67.0 74.3 81.9 25 19.4 21 A 23.5 25,6 27.9 32.8 38,0 416 49,6 56.0 62.8 70.0 77.6 85,5 30 20.2 22.3 24.5 263 29.1 34.2 39,6 45.5 51,8 5-8.4 65.5 73,0 80.9 89,2 35 20,8 210 25.2 27.6 30,0 35.2 40,8 46.9 513 60.2 67.5 75,2 83.3 91,9 40 21.5 233 26.0 28.4 30.9. 36.3 42.0 48.3 54.9 62.0 69.5 77.4 85.8 94.6 45 22.0 24.2 26.6 291 31.61 37.1 43.1 49.4 1 -56.2 1 -615 t -71_,2_ 79.3 _ 87.9_ 96.9 50 22.5 24.8 27.2 29.7.-32.41 38.0 44.1 1 -%6 1 -57.6 1 -65.0 1 -72.9 1 -81.2 1 -89,9 99,2 55 92 7 26.2 27,7 30 4 g 51,5 58.6- 74. 2 6 2 101.0 60 2 25.7 1 -28,2 A; t4,ti J JAI j - 45.7 52 A 59,7 1 -67A 1 .75. 1 7 F 10 .8 100 32.6 1 35.9 1 -39.4 143 i.5 1-1 IT6 1-130.3-1143,6 Table 5, Allowable Stress Design - Component and Cladding (C&C) Pressures (PSF) to be Resisted at Various Wind Speeds - Wind Exposure Category D, Wine Speed 100 105 110 115 120 130 1 140 150 160 170 180 190 200 1 210 Height (it) D D D D D D D D 0 D D D D D 0-15 21.2 23A 25.7 1-28.1 30k 35.9 41-.6-- 47.8 54.4 61 A 68.8 76.7 85,0- 93.7 20 22.3 24,6 27.0 1-29.5 32A 37.7 43.7 50'1 57.0 64.4 72.2 80A 89.1 98,2 25 23.1 25,5 28.0 1-30.6 33.3 39.0 45.3 52.0 59.1 66.8 74.9 83A 92.4 IDI,9 30 23,9 26.4 29,0 31.6 34,5 40.4 46,9 53.8 61.3 69.2 77.5 86A 95.7 105,5 35 24,5 27.1 29.7 32.5 35.3 41.5 48,1 55,2 62,8 70.9 79.5 88.6 98,2 108,3 4D 25.2 27.7 30.5 33,3 36,2 42,5 49,3 56,6 64.4 72.7 81,5 90.9 100.7 111,0 45 25.7 28.3 31 , 1- 34.0 37.0. 43.4 50.3 57,8 65.7 74.2 812 92.7 102.7 11131 so 26.2 28.9 31.7 34.6 1-3Z71 44 .3 51 3 58.9 67.1 1 -75.7 84.9 1 -94.6 104.8 11 ' .5 55 26.6 29.3 32.2 35.2 1-38.31 45.0 52,2 68.1 1 -76.9 86.2 1 -96, 1 106A 1 bo 29.8 32.7 35,1 91 11 tio 11 59,9 F5" SO 2 78A 87.6 1 -97.6 17.4 100 7Z5 83.2 1 163.03.0 Tables 3, 4, and 5 are based on ASCE 7-10 and consistent with the 2015 IBC, 2015 IRC and the 2017 Florida Building Code 47 PLO-, RONALD I. OGAWA ASSOCIATES, INC. 16835 ALGONQUIN STREET #443 HUNTINGTON BEACH, CA 92649 714-292-2602 714-847-4595 FAX PROJECT RIO-2686-17 JAMES HARDIE BUILDING PRODUCTS, INC. 1-886-542-7343 info(d)jameshardie.com Table 6, Allowable Wind Speed (mph) for HardiePanal Siding (Analytical Metho, Product Product Thickness inches) Width inches) Fastener Type Fastener Spacing Frame Type Stud Spacing inches) Building HeighP ' feet) B C D a C D Allowable Design load PSF) Exp 8 Exp C Expj j K4 GCp GCq HardiePanek* 5116 48 6d common 6 2X4 wood Hem -Fir 16 0-15 186 168 1 153 144 130 118 49.7 0.7 0,85 1,03 jhs60 1 1 085 1.4 0.18 20 186_ 164 149 144 127 116 49.7 03 0,9 1 0.86 1_4 0.18 25 186 160 147 144 124 114 49.7 0,7 0.94 11.08 1.12 1 085 1.4 0.18 30 186 157 144 144 121 112 497 0,7 0,98 1,16 1 0.85 1.4 0,18 35 182 154 142 141 120 110 49.7 073 1,01 1.19 1 0,86 14 F. `la 40 178 152 141 138 118 109 491 0.76 1.04 1,22 1 0,85 1A 018 45 175 150 139 136 117 108 497 0.785 1.065 1.245 1 0.85 1.4 0.18 50 172 149 138 134 115 107 493 0,81 1,09 1.27 1 0.85 74 0.18 515 170 147 137 132 114 106 49Y 0.83 1.11 729 F1 T0,85T-1 4 0.18 60 168 146 136 130 113 105 49,7 0.85 1 1.13 1,31 1 1 0.85 1.4 0.18' 100 139 124 116 108 96 90 49,7 0.99 1.26 143 h,60 1 10,851-1,8 0.18 HardiePanelS 5116 48 ad common 4 2X4 wood Hem -Fir 16 0.15 233 212 192 181 164 149 78.7 03 0.85 1.03 h:Z0 0.85 1.4 0,18 20 233 206 188 181 159 146 783 0.7 0,9 1.08 L 1 0,85 11.4 0,18 25 233 201 185 181 156 _143 78.7 07 0.94 1,17 1 0.85 1A 0.18 30 213 197 181 181 153 140 783 0.7 0.98 1,16 1 0,85 1,4 018 35 229 194 179 177 151 139 78,7 033 1.01 T_ 19 0115 1 " 0 1" 40 224 192 177 174 148 137 78,7 0.76 1.04 1.22 1 0,85 1 4 0111 45 220 189 175 171 147 136 78.7 0,785, 1.065 1,245 1 0,85 4 la so 217 187 173 168 145 134 783 0.81 1.09 1.27 7 1 0.85 1 a 55 214 185 172 166 144 133 787 0,83 1.11 27 1 10.85 14 1. 60 212 184 171 164 142 132 78.7 0.85 1.13 1.31 J_r6_ as 1 1 ja 100 175 155 146 136 120 113 78.7 0,99 1.26 1,43 h160 1 0,85 1.e 018 HardiePaneW 5116 48 W common 6 2X4 wood Hem -Fir 24 0_15 147 134 121 114 103 94 31-3 0,7 0.85 1.w h560 0.85 04 0,18 20 147 130 119 114 101 92 31,3 0.7 0.9 1.08 L 1 0,85 1A 0.18 25 147 127 116 114 98 90 31.3 63 0.94T1, 12 1 0.85 1.4 0.18 30 147 124 114 114 96 89 31.3 0.7 0.98 1,16 1 0,85 1,4 0.18 35 144 123 113 112 95 87 31.3 0.73 1.011 1.19 1 0.85 1.4 oAa 40 141 121 112 109 94 86 31.3 076 ISA L 085 a oil, 45 139 119 110 108 92 86 31.3 0.785 1.055 2L 1.245 L 1 0.85 1.4 0.18 50 13 118 106 91 31.3 0,81 1.09 7- 27 17 5785 1.4- 0,18 55 135 117 1 105 91 31.3 0.83 1.11 E29 1 0,85 1.41 0.18 6U 134 116 103 90 31.3 0. as 1.13 1 1 1 0,85 1.41 01B 100 111 86 31'3 O.W 126 1.43 h160 1 0 85 1,8 071_8 HardiePaneM 5/16 48 ad common 4 2X4 wood Hem -Fir 24 0-15 182 165 150 141 128 116 47.7 03 0,85 I.W h:= 1 0.8511o.as 14 0.18 20 182 160 146 141 124 113 47.7 0.7 0.9 1.08 1 0,85 IA 0.18 25 182 157 144 141 121 Ill 47.7 01 0.94 1,12 1 O 85 1,4 OAF 30 182 154 141 141 119 109 47.7 03 0.98 1,16 IA 0.18 35 178 151 139 138 117 108 47.7 6.73 11ol 1, is 1 0,85 1A 0.18, 40 174 149 138 135 116 107 47.7 0,76 1.04 1.22 1 0,85 14 0.18 45 172 147 136 133 114 106 0785 1.055, 1245 1 0.85 IA 0.18 50 169 146 135 131 113 105 47,7 47.7 0.81 109 1.27 1 0,85 114 0.16 55 167 144 134 129 112 104 47.7 0,83 1.11 LN 1 0.85 1.4 0.18 60 165 143 133 128 111 103 47,7 0.85 1.13 1.31 1 01 1A 0.18 100 137 121 114 106 94 88 47,7 0.99 1 126 1 1,43 ln>60 1 10.85 0.8 1 0.18 HardiePaneW 5116 48 4d, 0.091 in. shank X 0.225 in. HD X 1.5 in. long ring nail 4 edge 8 field 2X4 wood G.36S4 16 0_15 144 131 119 112 101 92 30.0 V 0.85 1.03 h:;80 1 0,85 1.4 0,18 20 144 127 116 112 1 98 90 30.0 0,7 0.9 1.08 1 0.85 IA mal 25 144 124 114 112 96 88 30.0 03 0.94 1.12 0.85 1.4 018 30 144 122 112 112 94 87 30.0 03 0.96 1,16 L 1 0,85 1.4 0.18 35 141 120 Ill 109 93 86 30.0 0.73 1.01 1.19 1 0.85 1.4 0.18 40 138 118 107 92 30.0 036 1.04 1.22 1 0.85 1A 0.18 45 136 117 105 91 30.0 0,785 1.055 1.245 1 0.85 1.4 0. 18shank5013419 89 30.0 O.81 1.09 1.27 1 0'e5 14 0.18 55 132 14, 1 ON 30,0 0,83 111 1.29 1 0,85 1A 0,16 16 14 0.18 100 n! 2) 1 3HR, 1.2 1.43 h>60 1 10.851 1.810 lal RONALD 1, OGAWA ASSOCIATES, INC. 16835 ALGONOUIN STREET #443 HUNTINGTON BEACH, CA 92649 714-292-2602 714-847-4595 FAX PROJECT: RIO-2686-17 JAMES HARDIE BUILDING PRODUCTS, INC. 1-888-542-7343 info@jameshardie.com 2015 18C, 2017 FSC 2015 18C, 2017 FBC Allowable, Ultimate Allowable, Nominal Design Wind, Speed, Design Wind, Speed, to ss 3-second gust mph) 3-second gust mph) Applicable to methods Applicable to Methods specified in [2015 18C, specified in E.cepboos I 2017 FBCI Section 16091.1. as determined by th'o- through 3 of 12016 IBC, Figures 1609.3(1). (2), or 2017 FBC) Section 3), Coefficients used in Table 6 calculations for V.,, rV-T,nd eagaosure category Wind exposure category Sitting K,, Product Stud Building Allowable Product Thickness Width Fastener FastenerFrame Spacing Height" B C D B C D Design inches) inches) Type Spacing Type inches) foot) Load Ex,jepC Exp 0 K. K,, GC. GC, 0-15 198 180163 153 139 126 55.6 03 0.85 1.03 hS60 1 0.851-14 10.18 Min, No 8 X 20 198 175 159 153 135 123 56.6 03 0.9 1,08 1 0,85 1 •14 10.18 25 198 171 157 153 132 121 56L 03 1 0.94 1.12 1 0,851-1,4 10,181in. long X Min. No. 30 198 167 154 153 130 119 56.6 0,7 58 1-1-161 1 0.65 14 018. 0.323 in 20 ga. 35 194 165 152 150 128 118 56,6 0,73 1.01 1.19, 1 0.85 A 0,18head 33 mil) X 40 190 162 150 147 126 116 56.6 0.76 1.04 1.22 1 0.85 1.4 0.18FlardoPaneW11448 diameter 6 3.625 in. 16 45 187 161 148 145 124 115 56.6 0.785 1.065 1,245 1 0.85 1A 018ribbed X 1.375 50 184 159 147 143 123 114 56,6 0.81 1,09 1,27 1 0,85 1A 0,18buglehead in metal 55 182 157 146 141 122 113 56.6 OM 1,11 1 29 1 0.85 1.4 0,18 screw' stud 60 180 156 145 139 121 112 56,6 0,85 1,13 1,31 1 0.85 471- 0.18 100 149 132 124 115 102 96 58.6 0.99 1,26 143 h>60 1 0.85 1.8 0.18 0-15 146 132 120 113 102 93 30,e 07 0,85 1,03 h:;50 1 0.85 1,4, 0.181 20 146 128 117 113 99 91 30,6 a7 0.9 1.08 1 Min. No 8 X 25 146 126 115 113 97 89 30,6 07 0.94 1, T27 1 0.85 1.4 0181Iin, long X Min, No. 30 146 123 113 113 95 Be 30.6 0,7 0.98 i'1e 1 0.86 14 f 0.1810.323 in 2098, 35 143 121 112 110 94 86 30.6073 1,01 1.19 1 0.85 1A 0.181head33millX 40 140 119 110 108 93 B", 30.6 0.76 1.04 1,22 1 0.85_ 0.181HardiePanelt1/4 48 diameter 6 3.625 in. 24 45 137 118 106 91 30-6 0.785 1.065 1.245 1 0.85 1,4 1A 0,18, ribbed X 1.375 SO 135 117 105 30.6 0.81 1-09 1.27 it 0.85 114 0,18buglehead in metal 55 134 116 104 90 30.6 0.83 111 1,29 1 0,8,5 71-4 0.18 screw` stud 60 132 115 102 89 30.6 0.85 1.13 1.31 1 0. &S 1,4 0.18 100 30,6 0,99 1,26 1,43 h,60 1 0A15 1.8 0,18 ET&F 0-15 198 180 163 153 139 127 56.7 0,7 0.85 1.03 1-1550 1 0,85-1.4 0,18 20 198 175 160 153 135 124 56.7 0,7 0.9 1.08 1 0.815 1 0,18, 0.100 in. 25 198 171 157 153 132 121 56.7 0.7 0,94 1.12 1 0.85 1.4. 018 knurled Min. No. 30 198 167 154 153 130 119 56.7 0!7 0.98 1,16 1 0.851 1,41 OA81shankX20ga. 35 194 165 152 150 128 118 56,7 0 2- 101 0.85 1.4 1 0.1811.5 in. long 4 edge 33 mil) X 40 190 163 150 147 126 116 56,7 0.76 1.04 LiL 1.22 L 1 0.85 1,4 0,181HardiePanelO5/16 48 X O25 in. 8 field 3.625 in, 16 45 187 161 149 145 124 115 56.7 0,785 1.065, 1.24$ 1 OA5 1.4 0.181 headX 1.375 50 184 159 147 143 123 114 56.7 0.81 1,09 1.27 1 0,85 1,4 0-18 diameterin metal 55 182 157 146 141 122 113 1 -56.7 0M_ 1,11 1,29 1 0.85 1A OA8 studpin fastener2 60 180 156 145 139 121 112 1 -563 0.85 1.13 131 1 0.85 11.4 0.18 100 149 132 124 115 102 96 56.7 0.09 1.26 IA3 h,i60 1 0,85 1.8 018 ET& F 0- 15 153 139 126 118 107 98 33.7 07 0,85 1,03 hr6O 1 0.85 1.4 0.18 20 153 135 123 118 104 95 33.7 03 0.9 1.08 1 0.85 1.14. 0.18 0.100 in. 25 153 132 121 118 102 N 33.7 0.7 a94 1.12 1 0.85. 01.4 Or, 15 knurled Min. No. 30 153 129 119 118 100 92 33.7 03 0.98 1,16 1 O 851 1.4 0.18. shankX20ga. 35 150 127 117 116 99 91 33.7 0.73 1.01 1.19 1 0.851-1.4 0,181 1 1,5 i n. long 4 edge 33 mil) X 40 147 125 116 114 97 90 33,7 0,76 1,04 77 221 O 85 11,4 0.18 HarcliePanel& 5116 48 X 0.25 in. 8 field 3.625 in. 24 45 144 124 115 112 96 89 33.7 0.785 1,065 1.245 1 0, 18151.4 0.18 headX 1375 50 142 122 1 3 110 95 88 33.7 0.111 1,09 1.27 1 0 85 1,4 0.18 0adiameterin metal 55 140 121 113 109 94 17 Z33.7 0.83 1 1 9 1 0.85 1A a 0.18 studpin faslenet- 2 60 139 120 112 107 37 987 333 3, 1 0), 1.4 0.18 100 115 33,7 0.99 1,26 P 160 1 0.85 1,8 018 I.- - o "--, - -- 2. Knuded shank pins shall penetrate the metal framing at least 1/4 inch. IIIII I"\ 0 GA W4 3. Buildingheight = mean roof height (in feet) of a building, except that eave height shall be used for roof angle G less than or equal to 10' (2-12 roof slope) it 4. Vs ultimate design wind speed A 5. V_ = nominal design wind speed 6. Linear interpolation of building height Is 60 ft) and wind speed is permitted. 7. Wind speed design assumptions per Analytical Method in ASCE 7-10 Chapter 30 C&C Part I and Part 3: Kz=l, K,,=0.85, GCp=-1.4 (hi$O), GCP=-1 (h>60)' s. LIMITATIONS OF USE: 1) Fastener pullout must be evaluated when installed a species of wood studs other than that which was tested. 21 In High Velocity Hurricane Zones (HVHZ) install per Miami -Dade County Florida, NOA 17-0406,06 C1,TP77 4-, It it 7 Florida Building Code Online Page I of 2 tieT T' 77777' '77 ' s BCIS Horne Log in : User Registration hot Topics I Submit Surcharge Stats & Facts Publications FBC Staff 5CIS Site Map : Links Search a waw ct Approval R UserdbP,uuulic ErEMjyGl oApoh, nr In > Applic,atio. Detail FL # FL12194- R6 Application Type Revision Code Version 2O,17 Application Status Approved Comments Archived Product Manufacturer Aluminum Coils, Inc. Address/Phone/ Email 5001 West Knox Street Tampa, FL 33634 813) 249- 9743 grahman@aluminunicoilsinc.com Authorized Signature Gareth Rahman grahmanCa,aluminumcoilsinc. com Technical Representative Paul Frost Address/Phone/ Email 5001 West Knox Street Tampa, FL 33634 813) 249- 9742 PFrost@aluminumcoilsinc.com Quality Assurance Representative Address/Phone/ Email Category Panel Walls Subcategory Soffits Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed Zachary R. Priest the Evaluation Report Florida License PE-74021 Quality Assurance Entity PRI Construction Materials Technologies, LLC Quality Assurance Contract Expiration Date 06/19/2020 Validated By Locke Bowden Validation Checklist - Hardcopy Received Certificate of Independence E _vftiAALiQn RgpQ[LQ4_T4 5gffitfinal. df . Referenced Standard and Year (of Standard) 514 p 0 _rd AAMA 1.402 Equivalence of Product Standards Certified By Sections from the Code YAA—r 2009 https:/'/xA,- v,, rw.floridabuilding.oro,/pr.;'pr app dtl.aspx?paraiii=wGEVXQw-tDquk24AUC%2fE.., 2/1/2018 Florida Building Code Online Page 2 of 2 Product Approval Method Method I Option D Date Submitted 09/06/2017 Date Validated 09/06/2017 Date Pending F5C Approval 09/13/2017 Date Approved 12/12/2017 Date Revised 12/15/2017 Summary of Products FL # Model, Number or Name Description 12194,1 Alumunum Coils Aluminum Soffit Aluminum soffit panels Limits of Use Installation Instructions Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Q4 T4 5ffi fir, I, if Impact Resistant: N/A Verified By: Zachary P. Priest PE-74021 Design Pressure: +80/-90 Created by Independent Third Party: Yes Other: See Evaluation Report for limits of use. Evaluation Reports ar- 121c'4 lag Report rjQ 4Z, Created by Independent Third Party: Yes Back Nezt L2nta Ct US :: Ir S 7 I sFl t'4 Rtig_- _2,5,Q 71 4 The State of Florida is an WCE0 employer. : : :: W n :: Wka0_aM=_Qat Uncle' Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send elearcrniC mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850 487,1395. "`Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S, Must provide the Department with an email address if they have one. The email; provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please C1,Ck LLg_ Product Approval Accepts; T1 cl im FE = Cred-, Card Safe https:/,', A,rww.floridabuildinc,.org,/'pr/'Pr_app dti.aspx?param=wGEVXQw-tDquk24AUC%2fE... 2/1//2018 TECHNICAL SERVICES, LLC EVALUATION REPORT Manufacturing: Quality Assurance: ALUMINUM COILS, INC. 5001 West Knox Street Tampa, FL33O34 813)249'9743 Tampa, FL Certificate ufAuthorization No. 29824 1752OEdinburgh Dr Tampa, FL33647 813)480- 342I FLORIDA BUILDING CODE 6 T" EDITION (2017) PR|Construction Materials Technologies (QUAS11O) Issued September t2O17 Category: Panel Walls Subcategory: unms Code Sections: 1404 5,1.170910 Properties: Wind Resistance RErEnswcca Certified CTLA 1847W AAMA 1402 2009 Certified Testing Laboratories (Tar1sr7) oTu\zorew AAMA 1402 onoo pn|Construction Materials Technologies (Tsroora) An/x'003'02'01 AAmA 1402 zoou PmConstruction Materials Technologies (TaToara) AC/x'003-02'02 AAMA 1*02 0000 L/m/TArmma 1 This report innot for use in the HVHZ. 2 Design wind loads oxa|| be determined in accordance with FBC Section 1609 1 Soffits shall balabeled inaccordance with FBCSection 17OS1V ^ 4. Installation of the evaluated products shall comply with this report, the FEC and the manufacturer's published application instructions. Where discrepancies exist between these sources, the more restrictive and FECcompliant installation detail shall prevail. 5, Installations shall meet the minimum ventilation requirements of FBC section 1203.2. 0. Field fastener withdrawal may be required by the AHJ for confirmation of existing substrates. All data shall be reviewed by a qualified design professional to ensure the fastener withdrawal meets or exceeds the minimum load resistance for the project requirements. 7. All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule O1G20-3. 0~ um/wu oo/us./wC Soffits TECHNICAL SERVICES, LLC PRODUCT DESCRIPTIONS 30" F'Channe( Pnyhznned nominal 0.O1O-inchthick, 31O5M-14aluminum F-channel. See Appendix Dfor dimension drawings. 3/8'J'Chaone| Preformed nominal 0.010-inchthick, 31O5V'14aluminum J-channel.See Appendix Dfor dimension drawings. Fascia Preformed nominal 0O1S-inohthick, 3105 M-14a|uminum fascia. See Appendix Dfor dimension drawings. 16^Q4Soffit Preformed nominal 0.0185'inch thick, 3105 H-14a|uminum aoffit9enaa provided in 18- inch sections. The reported net free ventilation areas are 22.3 in^/|in.ftfor the 'full want' configuration and 11.1 in /|in.hand for the 'center vent' configuration. See Appendix Dfor dimension drawings. 12" T4Soffit Preformed nominal 0,8135-inch thick. 3105 M-14 aluminum soffit | provided in 12' inch sections. The net free ventilation areas are 12.5 in^8in.ft for the fu|| vent' configuration and 4.2 in8in.ft for the 'center vent' configuration. See Appendix D for dimension drawings. This evaluation mpon/ oprovided for State mFlorida product approval under Rule o1ozn-a. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report /svalid. This evaluation report does not express nor imply warranty, i"manat/on, eomnmrndeu use, orother product attributes that are not specifically addressed herein, CREEK TECHNICAL SERVICES, LLC COMPLIANCE STATEMENT ALUMINUM COILS, INC Soffits The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building Code, 6to Edition (2017) as evidenced in the referenced documents submitted by the named manufacturer. 00% jill I [III,/ /.*,, vk'( R. P" , , 41 E N .. Tl\ No 74021 Ac Q. STATE OF 4U -Z 0 R O; CERTIFICATION OF INDEPENDENCE 2017.09.01 10:06:18 04'00' Zachary R. Priest, P.E. Florida Registration No. 74021 Organization No. ANE9641 CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. APPENDICES 1) APPENDIX A— Approved Systems (8 pages) 2) APPENDIX B— Installation Drawings (12 pages) 3) APPENDIX C— Design Wind Loads(4 pages) 4) APPENDIX D — Dimension Drawings (4 pages) ALC 15001.3 FL12194-R6 Page 3 of 3 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3, The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. 14 CREEK TECHNICAL SERVICES, LLC APPROVED SYSTEMS ALUMINUM COILS, INC Soffits Appendix A The following notes shall be observed when using the assembly tables below. 1. Maximum Design Pressures (MDP) were calculated using a 1.51 margin of safety per FBC Section 1404.5.1, 2. Refer to LIMITATIONS and sections of this evaluation when using the table(s) below. 3. Refer to INSTALLATION section of this report for installation detail when the information is not explicitly stated for the selected assembly. 4, The on -center (o.c.) spacing given is the maximum allowable attachment spacing for the rated system. 5. Unless otherwise specified, the Wood substrate shall be minimum No. 2 SPF (S.G. = 0.42) 2x lumber, Substrate attachment shall be designed by others in accordance with FBC requirements to meet the minimum design requirements for the project. 6. Unless otherwise specified, the Masonry substrate shall conform to ASTM C 90. Substrate attachment shall be designed by others in accordance with FBC requirements to meet the minimum design requirements for the project. 7. Typical fastening details are as follows: ALC 15001.3 a. 12" T4 Soffit — 12-inch o.c. Fastener Fastener Location Location e \ / ---------- \ b, 12"T4 Soffit— 4-inch o.c, Fastener Fastener Fastener Fastener Location Location Location Location c, 16" Q4 Soffit — 16-inch o.c. Fastener Fastener Location Location FL12194-R6 Page 1 of 8 This evaluation report is provided for State of Florida product approval under Rule 6IG20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, of other product attributes that are not specifically addressed herein, JCREEKTECHNICALSF-RVICEs. L.LC d. 16" Q4 Soffit — 8-inch o.c. Fastener Location F Fastener Fastener Location ALUMINUM COILS, INC Soffits Approved System Numbers and Definitions 12F-# Approved Systems for 12-inch Overhang with F-Channel 12J-# Approved Systems for 12-inch Overhang with J-Channel 16F-# Approved Systems for 16-inch Overhang with F-Channel 16J-# Approved Systems for 16-inch Overhang with J-Channel 24F-# Approved Systems for 24-inch Overhang with F-Channel 24J # Approved Systems for 24-inch Overhang with J-Channel Appendix A Approved Systems for 12-inch overhang with F-Channel Wall Connection Eave Connection System Panel MDP No. Width psi Substrate F-Channel Attachment Substrate Panel Attachment Fascia Cap Attachment Max. One (1) min. 3/8-inch head dia. nail, One (1) min. 3/8 x 318-inch One (1) min. 1 314-inch long x 0.072-inch dia. x min. 3/16- 12F-1 16-inch Wood min. 1.25-inch embedment spaced Wood crown staple spaced 16-inch inch head dia. trim nail 40,0 24-inch o.c. O.C. spaced 36-inch o.c. Max. Three (3) min. 3/4-inch x 1/4-inch One (1) min 3/4-inch x 1/4-inch One (1) min. 1 314-inch long x 0.072-inch dia. x min. 1/4-inch 48 12F 2 16-inch Wood crown staples in diamond pattern Wood crown staple spaced 8-inch o.c. head dia. trip nail spaced 48- 64.2 spaced 24-inch o.c. and securing each panel lap inch o.c. One (1) min 3/4-inch x 1/4-inch One (1) min. 1 3/4-inch long x 12F-3 Max. 16-inch Masonry One (1) 14 ga. 5/8-inch long T nail spaced 8-inch o.c, Wood crown staple spaced 8-inch o.c. 0.072-inch dia. x min, 1/4-inch head dia. trip nail spaced 48- 48 64.2 and securing each panel lap inch o.c. ALC15001.3 FL12194-R6 Page 2 of 8 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC ALUMINUM COILS, INC Soffits Appendix A Approved Systems for 12-inch overhang with J-Channel Wall Connection Eave Connection System Panel MDP No. Width pst) Substrate F-Channel Panel Attachment Substrate Panel Attachment Fascia Cap Attachment Attachment Three (3) min. 3/4- inch x 1/4-inch crown One (1) min. #8 x 1/2-inch One (1) min 3/4-inch x One (1) min. 1 3/4-inch long x 12J-1 Max. Wood staples in diamond long x 318-inch head diameter Wood 1/4-inch crown staple 0.072-inch dia. x min. 1/4-inch 48 16-inch pattern spaced 24- screw spaced 16-inch o.c. spaced 8-inch o.c. head dia. trip nail spaced 48- 64.2 inch o.c. connecting soffit to J-channel I I I inch o.c. I I I Approved Systems for 16-inch overhang with F-Channel Wall Connection Eave Connection System Panel MDP No. Width psf) Substrate F-Channel Substrate Panel Attachment Fascia Cap Attachment Attachment One (1) 18 ga. 1/4-inch crown x One (1) min. 1.75-inch x 16F-1 Max Masonry One (1) 14 ga. 5/8-inch long T nail Wood 1-inch leg staple spaced max. 0.072-inch diameter finishing nail with min. 3/16- 53.3 12-inch spaced max. 8-inch o.c. 4-inch o.c, and securing each inch head spaced panel lap 12-inch o.c. One (1) 18 ga. 1/4-inch crown x One (1) min. 1.75-inch x Max Three (3) 18 ga. 1/4-inch crown x 1- 1-inch leg staple spaced max. 0.072-inch diameter 16F-2 12-inch Wood inch leg staples in diamond pattern Wood 4-inch o.c. and securing each finishing nail vvith min. 3/16- 53.3 spaced 16-inch o.c. panel lap inch head spaced I 12-inch o.c. Max' One (1) 318-inchhead dia. nail, min. One (1) min 3/8-inch x 3/8-inch One (1) min. 1 3/4-inch long x 0.072 inch dia. x min' 16F-3 16-inch Wood 1.25-inch embedment spaced 24- Wood crown staple spaced 16-inch 3/16-inch head dia. trim nail t25.6 inch o.c. O.C. spaced 36-inch o.c. Three (3) min. 3/4-inch x 1/4-inch One (1) min. I 3/4-inch long 16FA Max Wood crown staples in diamond pattern wood One (1) min 3/4-inch x 1/4-inch x 0.072-inch dia. x min. 1/4- 27 16-inch spaced 24-inch o.c. crown staple spaced 8-inch o.c. inch head dia. trip nail 361 spaced 48-inch o.c. ALC 15001.3 FL12194-R6 Page 3 of 8 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. el CREEK TECHNICAL SERVICES, U-C ALUMINUM COILS, INC Soffits Appendix A Approved Systems for 16-inch overhang with F-Channel Wall Connection Eave Connection System Panel MDP No. Width psf) Substrate F-Channel Substrate Panel Attachment Fascia Cap Attachment Attachment One (1) 18 ga. 1/4-inch crown x One (1) min. 1.75-inch x 16F-5 Max Masonry One (1) 14 ga, 5/8-inch long T nail Wood 1-inch leg staple spaced 4-inch 0.072-inch diameter finishing nail with min, 3/16- 43.3 16-inch spaced 8-inch o.c. o.c. and securing each panel inch head spaced lap 16-inch o.c, One (1) 18 ga. 1/4-inch crown x One (1) min, 1,75-inch x Max. Three (3) 18 ga. 1/4-inch crown x 1- 1-inch leg staple spaced 4-inch 0.072-inch diameter 16F-6 16-inch Wood inch leg staples in diamond pattern Wood o.c. and securing each panel finishing nail with min. 3/16- 43.3 spaced 16-inch o.c. lap inch head spaced I I I I I 16-inch o.c. Approved Systems for 16-inch overhang with J-Channel Wall Connection Eave Connection System Panel MDP No. Width Psi Substrate J-Channel Substrate Panel Attachment Fascia Cap Attachment Attachment Max. Three (3) min. 3/4-inch x 1/4-inch One (1) min 3/4-inch x 1/4-inch One (1) min. I 3/4-inch long x 0.072-inch dia. x 23.5 16j-1 16-inch Woodoo crown staples in diamond patterncro Wood crown staple spaced 8-inch o.c. min. 1/4-inch head dia. trip 31.4 spaced 24-inch o.c. 1 1 1 nail spaced 48-inch o.c. ALC 15001.3 FL12194-R6 Page 4 of 8 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. ACREEKilTECHNICALSERVICEs. LLC ALUMINUM COILS, INC Soffits Appendix A Approved Systems for 24-inch overhang with F-Channel Wall Connection Center Connection Eave Connection System Panel MDP No. Width pso Substrate F-Channel Batten Panel Attachment Substrate Panel Attachment Fascia Cap Attachment Attachment One (1) 18 ga.1/4-inch Nominal 1x2 crown x 1-inch leg Not SYP staple spaced Three (3) 18 ga. 1/4- anchored to 12-inch o.c. securing One (1) 18 ga. 114- One (1) min. 1.75-inch x Max. inch crown x 1-inch rafter with one each panel lap inch crown x 1-inch 0.072-inch diameter 24F-I 12-inch wood leg staples in 1) min. 2.25- Wood leg staple spaced 8- finishing nail wish min. 80/-90 diamond pattern inch x 7d ring One (1) min. 1.75-inch inch O.C. 3/16-inch head spaced spaced 16-inch o.c. shank nail x 0.072-inch diameter 12-inch o.c. 24-inch o.c. finishing nail with min. 3116-inch head spaced 4-inch o.c. One (1) 18 ga.1/4-inch crown x 1-inch leg Nominal 1x2 staple spaced One (1) min, 1.5- No.2 SYP 12-inch o.c. securing One (1) 18 ga. 114- One (1) min. 1,75-inch x Max inch x 11 ga. anchored to each panel lap inch crown x 1-inch 0.072-inch diameter 80/ 24F-2 12-inch Wood smooth shank rafter with one Wood leg staple spaced 8- finishing nail with min, 76.6 roofing nail spaced 1) 7d x 2.25- One (1) min. 1.75-inch inch o.c. 3116-inch head spaced 16-inch o.c. inch ring shank x 0,072-inch diameter 12-inch o.c. nail 24-inch o.c. finishing nail with min. 3/16-inch head spaced 4-inch o.c, One (1) 18 ga. 114-inch crown x 1 -inch leg Nominal 1x2 staple spaced No.2 SYP 12-inch o.c. securing One (1) 18 ga. 1/4- One (1) min. 1.75-inch x Max One (1) 14 ga. 5/8- anchored to each panel lap inch crown x 1 -inch 0.072-inch diameter 80/ 24F-3 12-inch Masonry inch long T nail rafter with one Wood leg staple spaced 8- finishing nail with min. 76.6 spaced 8-inch o.c, 1) 7d x 2.25- One (1) min, 1.75-inch inch o.c. 3/16-inch head spaced inch rina—shank x 0.072-inch diameter 12-inch ox. nail 24-inch o.c. finishing nail with min, 3/16-inch head spaced I 4-inch o.c. ALC15001.3 FL12194-R6 Page 5 of 8 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. ACREEKTECHNICALSERVICES, ILLC ALUMINUM COILS, INC Soffits Appendix A Approved Systems for 244nch overhang with F-Channel Wall Connection Center Connection Eave Connection System Panel MDP No. Width psi) Substrate F-Channel Batten Panel Attachment Substrate Panel Attachment Fascia Cap Attachment Attachment One (1) 18 ga.1/4-inch crovvn x 1-inch leg Nominal 1x2 staple securing the No.2 SYP nailer of each female Three (3) 18 ga,1/4- anchored to lock or spaced One (1) 18 ga. 1/4- One (1) min, 1.75-inch x Max. inch crown x 1-inch rafter with one 16-inch o.c. securing inch crown x 1-inch 0.072-inch diameter 2 4F-4 Wood leg staples in each panel lap Wood leg staple spaced 8- finishing nail with min. 801-60 16-inch diamond pattern 1) min. 2.25- o.c. and securing 3116-inch head spaced spaced 16-inch o.c. inch x 7d ring shank nail One (1) min, 1,75-inch each panel lap 16-inch o.c. 24-inch o,c. x 0.072-inch diameter finishing nail with min. 3/16-inch head spaced 4-inch o.c. One (1) 18 ga. 1/4-inch crown x 1 -inch leg staple securing the Nominal 1x2 nailer of each female One (1) min. 1.5- No.2 SYP lock or spaced One (1) 18 ga. 1/4- One (1) min. 1.75-inch x Max inch x 11 ga. anchored to 16-inch o.c, securing inch crown x 1-inch 0.072-inch diameter 24F-5 Wood smooth shank rafter with one each panel lap Wood leg staple spaced 8- finishing nail with min. 801-60 16-inch roofing nail spaced 1) 7d x 2.25- inch o.c. and securing 3/16-inch head spaced 16-inch o.c. inch ring shank One (1) min, 1.75-inch each panel lap 16-inch o.c. nail 24-inch o.c. x 0.072-inch diameter finishing nail with min. 3/16-inch head spaced 4-inch o.c, ALC15001.3 FL12194-R6 Page 6 of 8 This evaluation report is provided fior State of Florida product approval under Rule 61G20-3, The manufacturer shall notify CREEK Technical Services, LLC of any product changes of quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, of other product attributes that are not specifically addressed herein. LCREEKTECHNICALSERVICES, LLC ALUMINUM COILS, INC Soffits Appendix A Approved Systems for 24-inch overhang with F-Channel Wall Connection Center Connection Eave Connection System Panel MDP No. Width pst) Substrate F-Channel Attachment Batten Panel Attachment Substrate Panel Attachment Fascia Cap Attachment One (1) 18 ga. 1/4-inch crown x 1-inch leg staple securing the Nominal 1x2 nailer of each female No.2 SYP lock or spaced One (1) 18 ga. 1/4- One (1) min. 1,75-inch x Max One (1) 14 ga. 5/8- anchored to 16-inch o.c. securing inch crown x 1-inch 0,072-inch diameter 24F-6 16-inch Masonry inch long T nail rafter Wth one each panel lap Wood leg staple spaced 8- finishing nail with min. 801-60 spaced 8-inch o.c. 1) 7d x 2.25- inch o.c. and securing 3/16-inch head spaced inch ring shank One (1) min. 1.75-inch each panel lap 16-inch o.c. nail 24-inch o,c. x 0.072-inch diameter finishing nail with min. 3/16-inch head spaced 4-inch o.c. L i ALC15001.3 FL12194-R6 Page 7 of 8 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LI-C of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. ACREEKTECHNICALSERVICES, LLC ALUMINUM COILS, INC Soffits Appendix A Approved Systems for 24-inch overhang with J-Channel Wall Connection Center Connection Eave Connection System Panel MOP No. Width Pso Batten J-Channel Batten Panel Attachment Substrate Panel Attachment Fascia Cap Attachment Attachment Nominal 1x2 No.2 SYP scabbed between rafters with One (1) 18 ga, 1/4- one (1) min. 2.25- inch crown x 1 -inch Nominal 1x2 inch x 7d ring shank leg staple spaced No.2 SYP Three (3) 18 nail straight -nailed 12-inch o,c. anchored to ga.114-inch crown through the rafter securing each panel One (1) 18 ga. %- One (1) min, 1.75-inch Max, rafter with one x 1-inch leg into the end of the lap inch crown 1-inch x 0.072-inch diameter 24J-1 1 2-inch 1) min. 2.25- staples in diamond batten or two (2) Wood xlegstaplespaced finishing nail with min. 60 inch x 7d ring pattern spaced 16- min. 2.25-inch x 7d One (1) min. 1,75- 8-inch o.c. 3/16-inch head spaced shank nail inch o.c. ring shank nails toe- inch x 0.072-inch 12-inch o.c. 24-inch o.c. nailed on either side diameter finishing of the batten at nail with nun. 3/16- each battenhafter inch head spaced intersection. Max. 4-inch o.c. rafter spacing is 24-inch o.c. . Nominal 1x2 No.2 SYP scabbed One (1) 18 ga. 114- between rafters with inch crown x 1 -inch one (1) min. 2.25- leg staple securing Nominal lx2 inch x 7d ring shank the nailer of each No.2 SYP Three (3) 18 nail straight -nailed female lock or One (1) 18 ga. 1/- anchored to ga. 1/4-inch crown through the rafter spaced 16-inch o.c. inch crown x 1-inch One (1) min. 1.75-inch Max. rafter with one x 1 -inch leg into the end of the securing each panel leg staple spaced x 0.072-inch diameter 24J-2 16-inch 1) min. 2.25- staples in diamond batten or two (2) lap Wood 8-inch o.c. and finishing nail with min, 53.3 inch x 7d ring pattern spaced 16- min. 2.25-inch x 7d securing each panel 3116-inch head spaced shank nail inch o.c. ring shank nails toe- One (1) min. 1.75- lap 16-inch ox. 24-inch o.c. nailed on either side inch x 0.072-inch of the batten at diameter finishing each batten/rafter nail with min, 3/16- intersection. Max. inch head spaced rafter spacing is 4-inch o.c, 24-inch o.c. ALC15001.3 FL12194-R6 Page 8 of 8 This evaluation report is provided for State of Florida product approval tinder Role 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. A CREEK TECHNICAL SERvicEs, LLC INSTALLATION ALUMINUM COILS, INC Soffits UTITIT-71711TOU; Note - Refer to the APPROVED SYSTEMS section of this report for additional installation details of a selected system and maximum design pressures limitations. System No. [ Installation Detail 1217-1 & 1217-3 M i G I x1d 61 J a nail wjtI i r; , IN" min. ,if twd I or S1,1ji, "%,i I wiUh m1r, -'nj '_Jemsot' { ftl- concr "I". ox bl'—k s.bstrate3 , spa,ed as no' aj zitive. FASCIA SLIP BOARD FASCIA TRIM SOFFIT (OVERHANG WIDTH VARIES) FASCIA LIP 1/4" STAPLE SOFFIT TO FASCIA BOARD #T50 3/8" X 3/8" STAPLE 16" O.C. k—PAINTED S.S. 1 3/4" TRIM NAIL MIN. 5 NAILS PER 12' PIECE SOFFIT & FASCIA DETAIL ALC 15001.3 FL12194-R6 Page 1 of 12 This evaluation report is provided for State of Florida product approval tinder Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. A=° CREEK TECHNICAL SERVICES, LLC System No. I Installation Detail 12F-2 3/4' X 1/4' --, CROWN STAPLES USING A DIAMOND PATTERN F' CHANNEL CAN BE INSTALLED WITH THE NAILING FLANGE UP OR DOWN WOOD SUBSTRATE ALUMINUM COILS, INC Soffits Appendix B OPEN RAFTER SOFFIT STAPLE DIAMOND -PATTERN I; DETAIL STAFUS FACIA E30ARO / M 3/4' X 1/4" CROWN FACIA BOAR STAPLE "8" ON CENTER 1-3/4- TRIM JNMAIL D SS, 1-3/4" TRIM NAILA PAINTED S,S, PAINTED S.S. 413' -FASCIA CAP 3/4" X 1/4" CROWN STAPLE SOFFIT- max, 12 -inch Span SOFFIT SOFFIT &—EA—SCIA DETAIL ALC15001.3 FL12194-R6 Page 2 of 12 This evaluation report is provided for State of Florida product approval under Rule 611320-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for Which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LILC System No. I Installation Detail 12J-1 619aff-RiTatA 3/4- X 1/4- CROWN STAPLE -24- ON CENTER USING A DIAMOND PATTERN J-CHANNEL 1-3/4- TRIM NAIL screwed to SOML with01111 go N PAINTED S.S. 48" 3/2- X 3/8 head OX. diameter screw, 16" 0 SOFFIT -max, 12-inch Span WOOD OR BLOCK SUBSTRATE ALUMINUM COILS, INC Soffits Appendix B 9jBETVUM SOFFIT STAPLE TAPLES DIAMOND EA11-FRN Jj L 12 E TA I L FACIA BOARD / 9' KTWEEN I TAKXS FASCIA CAP 3/4' X 1/4- CROWN STAPLE *8' ON CENTER 1-3/4- TRIM NAIL PAINTED S. S. SOFFIT FACIA BOARD FASCIA CAP 3/4- X 1/4- CROWN STAPLE SOFFIT & FASCIA DETAIL ALC15001. 3 FL12194-R6 Page 3 of 12 This evaluation report is provided for State of Florida product approval under Rule 61G20-3, The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVIcEs. LILC ALUMINUM COILS, INC Soffits Appendix B System No. Installation Detail I I- TRIM NAIL FASCIA BOARD FASCIA CAP OPEN RAFTER 11-1-4- CROWN STAPLE FASCIA BOARD 16F-1 SOFFIT & FASCIA 16F-5 DETAIL. FASCIA CAP; REFER TO SOFFIT I FASCIA DETAIL F" CHANNEL SOFFIT; MAX, 16' SPAN MASONRY SUBSTRATE ALC15001.3 FL12194-R6 Page 4 of 12 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC System No. I Installation Detail Min. 3/e" head dia, nail with min. 1?4` WCx-,3 or minx 0.097" dia. T-nail or z,---ub nail With Will, 5/' for, concrcta or, b1c'C'k M.l 11;')ted above, FASCIA SLIP BOARD FASCIA TRIM SOFFIT (OVERHANG WIDTH VARIES) 16F-3 I I 1 11 \-"F" CHANNEL or Block W FASCIA LIP 1/4" STAPLE SOFFIT TO ASCIA BOARD #T50 8" X 3/8" STAPLE 16" O.C. 1-1 <1 1 3/4" TRIM NAIL MIN. 5 NAILS PER 12' PIECE SOFFIT & FASCIA DETAIL ALC15001.3 FL12194-R6 ALUMINUM COILS, INC Soffits Appendix B Page 5 of 12 This evaluation report is provided for State of Florida product approval under Rule 611320-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. A CREEK TECHNICAL SERVICES, LLC 16F-4 No. I Installation Detail 3/4* X 1/4* ---, CROWN STAPLES USING A DIAMOND PATTERN I F' CHANNEL CAN BE INSTALLED WITH THE NAILING FLANGE UP OR DOWN WOOD SUBSTRATE 1-3/4- TRIM NAIL PAINTED S.S, 48' D.C. ALUMINUM COILS, INC Soffits Appendix B 3/W KTVM OPEN RAFTER SOFFIT STAPLE DIAMOND PATTERN 3/9'KWEEM/ 11 DETAIL FACA BOARD / I t ------ ri ASCIA CAP 3/4- X 1/4' CROWN STAPLE "B' ON CENTER SOFFIT—Tnax. 16-inch span 1-3/4- TRIM NAIL PAINTED S.S. SOFFIT FACIA BOARD FASCIA CAP 3/4' X 1/4' CROWN STAPLE SOFFIT &. FASCIA DETAIL ALC15001,3 FL12194-R6 Page 6 of 12 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. ACREEKlid TECHNICAL SERVICES, ILLC ALUMINUM COILS, INC Soffits System No. Installation Detail I J" TRIM NAIL FASCIA BOARD PAINTEU S,S. 1_.,-FASCIA CAP SOFfIT jj 1-sJ- CROWN STAPLE OPEN RAFTER I'ASM BOARD STAPLES SOFFIT & FASCIA US1116 A, DIAMOND PATTERN; REFER TO DETAIL 16F-2 & SOFFIT STAPLE 16F-6 DIAMOND PATTERN DETAIL FASCIA LAP; REFER 10 SOFFIT & FASCIA DETAIL 8 F" CHANNEL SOFFIT: MAX, 16" SPAN WOOD SUBSTRATE SOFFIT STAPLE DIAMOND PATTERN ALC15001.3 FL12194-R6 Page 7 of 12 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES. ILLC System No. I Installation Detail 16J-1 3/4- X 1/4' CROWN STAPLE -24- ON CENTER USING A DIAMOND PATTERN WOOD OR BLOCK SUBSTRATE OPEN RAFTER 1-3/4' TRIM NAJI PAINTED S.S. 48" O.C. SOFFIT -max. 16-incli span ALUMINUM COILS, INC Soffits Appendix B 31W 91TVM SOFFIT STAPLE DIAMOND PATTERN DETAIL FACIA BOARD 9rTWM1 ; - STAPLO ASCIA CAP 3/4" X 1/4' CROWN STAPLE "8' ON CENTER 1-3/4- TRIM NAIL PAINTED S.S. SOFFIT FACIA BOARD FASCIA CAP 3/4- X 1/4" CROWN STAPLE S,OFFI! & FASCIA QUAIL ALC15001.3 FL12194-R6 Page 8 of 12 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. LCREEKTECHNICALSERVICES, LLC ALUMINUM COILS, INC Soffits Appendix B System No. Installation Detail I I- TRIM NAIL FASCIA BOARD PAINTED S.S. 1*4STAPLES - CROW" FASCIA CAP USING A DIAMOND SOFFIT- 1PATTERN; REFERSTAPLE10 LROWN S IAPLE S OF DIAMOND PATTERN DETAIL I TRIM NAIL FASCIA BOARD PAINTED S.S. SOFFIT 8 FASCIA 24F-1 & DETAIL 24F-4 CROWN STAPLE FASCIA CAP: REFER TO SOFFIT a FASCIA DETAIL lj Nominal SYP Batten Anchored to SOFFIT; MAX, 24' F-CHANNEL Ratlers -411 one Id Ring shank Nair at WOOD SUBSTRATE— every Rafter SOFFIT STAPLE DIAMOND PATTERN ALC15001.3 FL12194-R6 Page 9 of 12 This evaluation report is provided for State of Florida product approval under Rule 611320-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC ALUMINUM COILS, INC Soffits Appendix B System No. Installation Detail I I' TRIM NAIL FASCIA BOARD PAINTED S.S. I -I' SMOOTH SHANK FASCIA CAP ROOF HAILS SOFFIT 1-,4- CROWN STAPLE I TRIM NAIL FASCIA BOARD PAINTC0 S.S. SOFFIT 8, FASCIA 24F-2 & DETAIL 24F-5 CROWN STAPLE FASCIA CAP: REFER 10 SOFFIT & FASCIA DETAIL Nominal 1-%2' SYP Batten Anchored to SOFFIT; MAX. 24- F-(HANNEL Rafters -ith one 7d RM Shl.h N84 at every Rafter WOOD SUBSTRATE- ALCI5001.3 FL12194-R6 Page 10 of 12 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LILC ALUMINUM COILS, INC Soffits App'endix B System No. Installation Detail I RIM RAIL FASCJA BOARD PAINTED S.S. I' GA T-NAILS FASCIA CAP SOFFIT 1'- CROWN STAPLE I TRIM NAIL FASCIA BOARD PAINTED S.S. SOFFIT 8, FASCIA 24F-3 & \ DETAIL 24F-6 r 1',4' CROWN STAPLE FASCIA CAP; REFER TO SOFFIT & FASCIA DETAIL Nominal 1'X2' SYR Batten Anchored to SOFFIT; MAX. 24" f-CHANNEL Rafters with one 7d Ring shank Nal at every Rafter MASONRY ALC'I 5001,3 FL12194-R6 Page 11 of 12 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3, The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEKAliTECHNICALSERVICES, LLC ALUMINUM COILS, INC Soffits Appendix B System No. Installation Detail 71 11' TRIM NAIL FASCIA BOARD PAINTED S.S. I"xi- CROWN FASCIA CAP STAPLES SOFFIT USING A DIAMOND PATTERN; REFER TO SOFFIT STAPLE ANTILIEYERED RAFTER CROWN STAPLE J_aDIAMONDPATTERN DETAIL FASCIA BOARD SOFFIT & FASCIA I t~ TRIM NAIL PAINTEDS.S. DETAIL 24J-1 & CROWN STAPLE 24J-2 FASCIA CAP; REFER TO SOFFIT L FASCIA Nominal I' x 2" SYP battens between letters and SOFFIT; MAX. 24- cabbed securedued with one (I ) 7d Tiny shank na+l st,alghl-nailed Inrough the fairer Into the end WOOD SUBSTRATE— t'hebatten of two 12) Id ng siranl, Palls We nailed on either cede of The ballefn at the b. ftew'.ne' mIt'secho" SOFFIT STAPLE DIAMOND PATTERN ALC15001. 3 FL12194-R6 Page 12 of 12 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. TEc*m/cAL SEnv/cEs'LLC DESIGN WIND LOADS ALUMINUM COILS, INC Soffits Appendix C The following tables provide design wind loads for components and cladding inaccordance with Section1609 of the F8Cand ASCE74Ounder the following provisions: 1, Wind speeds for risk category 1, 11, 111, and IV buildings shall be as defined in Section 1609 of the FBC. 2, Exposure O.C.and Dshall beaadefined insection 1808cVthe F8C. 3. Design wind loads are provided only for waUo1soffits with mean roof height less than o,equal m00-ft. 4. All calculations are based onaneffective wind area o<1O_ftrorless. 5. Topographic factors such as escarpments or hills have,been excluded from the analysis. 8. Wind directionality factor, Ku=0.85 T V*j is shown in the tables below. Design pressures are multiplied by 0.6 in accordance with Section 1609.1.3 of the FBC. 8. Projects with mean roof heights greater than 60-ft shall be evaluated by a licensed design professional. 8. Zones 4and 5shall bedefined ooshown below. Dimension ^u^shall be1UY4of the least horizontal dimension or(U.4xMean Roof H*ighV.whichever io This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes of quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC ALUMINUM COILS, INC Soffits Appendix C Design Wind Pressures for Soffits in Exposure B... Building Type Zone Mean-, Roof-,,' Height (ft) Basic Wind Speed' mph)", 130 140 150 160 170 180 190- 260 20 16.9 19,8 22.9 26.3 30.0 33.8 37.9 42.2 46.8 25 19.8 22.9 26,3 30.0 33,8 37.9 42.2 46,8 30 1 16.9 16,9 19.8 22.9 26.3 30.0 33.8 37.9 42.2 46.8 4 40 18.3 21.5 24.9 28.6 32,5 36,7 41.2 45.9 50.8 50 19.5 22,9 26.5 30.5 34.7 39.1 43.9 48,9 54.1 Enclosed 60 20.5 24.0 27.8 32.0 36.4 41.1 46.0 51.3 56.8 Negative Loads) 20 20.8 24.4 28.3 32.5 37.0 41.7 46,8 52.1 57,8 25 20.8 24A 28.3 32,5 37,0 41.7 46.8 52.1 57.8 30 20.8 24.4 28,3 32.5 37.0 413 46.8 52.1 57.8 5 40 22.6 26.5 30.7 35.3 40,1 45.3 50.8 56.6 62.7 50 24.1 28.2 32.8 37.6 42.8 48.3 54.1 60.3 66.8 60 253 29.6 34.4 39.5 44,9 50.7 56.8 633 70.1 20 10.8 12.7 14.7 16.9 19.2 21.7 243 27.1 30.0 25 10.8 12.7 14.7 16.9 19.2 21,7 24.3 27.1 30.0 30 10.8 12.7 14.7 16.9 19.2 21.7 24.3 27.1 30,0 4 40 11.7 13.8 16.0 18.3 20,8 23.5 26.4 29,4 32.5 50 12.5 143 17.0 19.5 22,2 25.1 28.1 31.3 34.7 Enclosed 60 13.1 15.4 17.8 20,5 23.3 26.3 29.5 32.9 36,4 Positive Loads) 20 10.8 12.7 14.7 16.9 19.2 21.7 24.3 27.1 30.0 25 10.8 12.7 14,7 16.9 19.2 21.7 24.3 271 30.0 30 10.8 12.7 14.7 16.9 19.2 21.7 24.3 27.1 30.0 5 40 11.7 13.8 16.0 18.3 20.8 23.5 26A 29.4 32,5 50 12.5 143 17.0 19,5 22,2 25.1 28.1 31.3 34.7 60 13.1 15.4 17.8 20.5 23.3 26.3 29.5 32.9 36.4 ALC 15001.3 FL12194-R6 Page 2 of 4 This evaluation report is provided for State of Florida product approval under Rule 61G20-3, The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC ALUMINUM COILS, INC Soffits Appendix C Design Wind Pressures for Soffits in Exposure C Building Type Zone': Mean" Roof Heightft) BasicWind Speed mph)--,` 120' 130 140 18 1901 200 20 21. 7-- -25.4 29.5 33.8 38.5 43.5 748.7 54.3 6U 25 22. 6 -26.6 30.8- 35.4 40.2 45.4 50.9 56.7 62.8 30 23. 6 -27.7 32.1 36.9 41.9 47.3 53.1 59,11 65.5 4 40 25. 0 -29.4 34.1 39.1 44.5 50.2 56.3 62.7 69.5 50 26, 2 -30-8 35,7 41 .O 46.6 52.6 59.0 65.8 72.9 Enclosed 60 27.2 -31.9 37.0 42.5 48.3 54.6 61.2 68.2 75.5 Negative Loads) 20 26.7 -31A 36,4 41.8 47.5 53,7 60,2 67.0 74,3 25 27. 9 -32.8 38.0 43.6 49,6 56.0 62.8 70.0 77.6 30 29, 1 -34.2 39.6 45.5 51.8 58.4 65.5 73.0 80.9 5 40 30. 9 -36.3 42.1 48.3 54,9 62.0 69.5 77.5 85.8 50 32, 4 -38.0 44.1 50.6 57,6 65.0 72.9 81.2 89.9 60 33. 6 -39.4 45.7 52.5 59.7 67A 75.5 84.2 93.2 20 13. 9 16.3 18,9 21.7 24,7 27.9 31.2 34.8 38,5 25 14, 5 17.0 19.7----22.6 25.8 29.1 32.6 36.3 40.3 30 15, 1 17.7 20.6 23.6 26,9 30.3 34.0 37.9 42,0 4 40 16. 0 18,8 21.8 25.1 28.5 32.2 36.1 40.2 44,5 50 16. 8 19.7 22.9 26.3 29.9 33.7 37,8 42,1 46.7 Enclosed 60 17A 20.5 23.7 2T2 31.0 35,0 39.2 43.7 48.4 Positive Loads) 20 13.9 16.3 18.9 21.7 24,7 27.9 31.2 34,8 38.5 25 30 14, 5 17.0 15.1 17.7 19.7 20.6 22.6 23.6 25.8 26.9 29.1 30.3 32.6 34.0 36.3 37.9 40.3 42.0 5 40 16. 0 18.8 21.8 25.1 28.5 32,2 36.1 40.2 44.5 50 16, 8 19.7 22.9 263 29,9 33.7 37.8 42.1 46.7 60 17. 4 20,5 23.7 27.2 31.0 35.0 39.2 43.7 48.4 ALC 150013 FL12194-R6 Page 3 of 4 This evaluation report is provided for State of Florida product approval under Rule 6IG20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. ACREEKT TECHNICAL SERVICES, LLC ALUMINUM COILS, INC Soffits Appendix C Design Wind Pressures for Soffits in Exposure D Building Type Zone Mean Roof Height'ft dBasicWindSpee mph) Z 120,- 130 140 1 50- 16 0 71 0 80: 190 200 20 2&0 30.5 35.4 40.6 46.2 52.2 58.5 65.2 72.2 25 27.0 31.6 36.7 42.1 47.9 54.1 60.6 67.6 74.9 4 30 40 27.9 29.4 32.8 34.5 38.0 40.0 416 45.9 49.6 52.2 56,0 62.8 66.1 70.0 73.6 7T5 81.6 50 30.6 35.9 41.6 47.8 54.3 58.9 61.3 68.8 76.6 84.9 Enclosed 60 31.5 37.0 42.9 49.3 56,11 63,3 70,9 79.0 87., Negative Loads) 20 32.1 37.7 43.7 50.1 57.0 64.4 72.2 80.4 89.1 25 33.3 39.1 45.3 52,0 2 66.8 74.9 83.4 92.4 30 34,5 40A 46.9 53.8 61.3 69,2 77,5 86.4 95.7 5 40 36.2 42.5 49,3 56.6 64.4 72.7 81.5 90.9 100.7 50 37.7 443 51.4 58.9 67.1 75,7 84.9 94,6 104.8 60 38,9 45.7 53.0 60,8 69.2 78.1 87.6 97.6 108.1 20 16.7 19.5 22.7 26.0 29.6 33,4 37.5 41.7 46.3 25 17.3 20.3 23.5 27.0 30.7 34.7 38.9 43.3 48.0 30 17.9 21.0 24.3 27.9 31.8 35.9 40.2 44.8 49.7 4 40 18.8 22,1 25.6 29.4 33.4 37.8 42.3 47,2 52.2 50 19.6 23.0 26.7 30.6 34.8 393 44.1 49.1 54.4 Enclosed 60 20.2 23.7 2T5 31,6 35.9 40.5 45,4 50.6 56.1 Positive Loads) 20 16.7 19,5 22.7 26.0 29.6 33.4 37.5 41.7 46.3 25 17.3 203 23.5 27.0 3U 34.7 38.9 433 48,0 30 17.9 21.0 24.3 27.9 31.8 35,9 40,2 44,8 49.7 5 40 18.8 22.1 25.6 29.4 33.4 37.8 423 47.2 52.2 50 19.6 23.0 26.7 30.6 34.8 39.3 44.1 49.1 54.4 60 20.2 23.7 27.5 31.6 35.9 40.5 45,4 50.6 56.1 ALC 15001.3 FL12194-R6 Page 4 of 4 This evaluation report is provided for State of Florida product approval under Rule 6IG20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC 3/8" F-Channel 3/8" 3/8" JI-Channel ALC15001,3 3/4" -1 81, HEM I 7 3/4" FI-12194-136 LS-OMIT11C "11W 3/8' PROFILE ISOMETRIC VIEW 3/8' PROFILE ALUMINUM COILS, INC Soffits Appendix D 1 of 4 This evaluation report is provided for State of Florida product approval under Rule 611320-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. AT EETECHNICAL SERVICES, LILC Fascia 3/4" 7/8" 1/8" HEM 6"FASCIA 7" BLANK 1/4" ISOMETRIC VIEW ALUMINUM COILS, INC Soffits Appendix D ALC15001.3 FL12194-R6 Page 2 of 4 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVIcEs, LLC 16" Q4 Soffit 0 2s, TP 0, UF TIP J. d:BLANI4 3 / 8 PROFILE 2 1 i5l 'up ALUMINUM COILS, INC Soffits Appendix D ALC15001. 3 FL12194-R6 Page 3 of 4 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC 12" T4 Soffit 3 1/8" 16" 2K W 7/8" 1 3 1/8" 3 112" Y 1/2" 13.7S" BLANK 3/8" PROFILE P5 UP 0 0 12-1 TIP 1/2" 112" 1/2" END OF REPORT ALUMINUM COILS, INC Soffits Appendix D ALC15001.3 FL12194-R6 Page 4 of 4 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. Florida BulldincTL_ Code Online Page I of 3 BCIS, Home Log In User Registration Hot Topics Submit Surcharge Scats & Facts Publications FBC Staff y BCIS Site Map Links Search rProduct Approval USER: Public User L'rQg=_&pP'aval Men LI > R!n'j'VLLg! Ap Lhjnn,5ear in > t_,pjpjjWD > applicationlication DetailLLi2 p5 FL7006-RIOU-2 FL 4 Application Type Revision Code Version 2017 Application Status Approved Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary, Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Certification Agency Validated By Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By IKO Industries, Ltd 40 Hansen Road South Brampton, NON -US L6W 3H4 708) 496-2800 Ext 200 rmetzOO!@tampabay,rr.com Robert Metz rmetzOOI@tampabay,rr.com Bob Metz REMCO of Pinellas 456 Avila Circle NE Saint Petersburg, FL 33703 727) 776-5261 rmetzOO1@tampabay,rr.com Don Shaw IKO Industries LTD 120 Hay Rd. Wilmington, DE 19808 717) 579-6706 don.shaw@iko.com Roofing Asphalt Shingles Certification Mark or Listing FM Approvals - CER Locke Bowden Validation Checklist - Hardcopy Received ASTM D3161 modified to 110 mph ASTM D3462 ASTM D7158 Class H ASTM E108 y"I 2016 2010 2011 2011 https:,',INNr\N,,w.floridabuilding.or-lprlpr_app_dtl.aspx?parani=wGEVXQxA-tDqse7mYBd2b'IK... 2/6/2018 Florida Building Code Online Page 2 of ' ) Product Approval Method Method I Option A Date Submitted 10/08/2017 Date Validated 10/30/2017 Date Pending FBC Approval Date Approved 11/01/2017 Summary of Products FL # Model, Number or Name Description 7006.1 Cambridge, Cambridge HID, Laminated architectural fiberglass asphalt shingle Biltmore and Biltmore HD manufactured at IKO's Kankakee, IL; Hawkesbury, Ont.; Wilmington, DE; Sylacauga,AL and Toronto, Ont. plants Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes 26- Approved for use outside HVHZ: Yes 20L71 frgM_fM pdf Impact Resistant: N/A FL7QQ6 RIO C CAC Letter - ASTM D3462 letter - (9-26- 291Z]dfDesignPressure: N/A Other. ELZO06 RIO Q-26- Mlzl Of Quality Assurance Contract Expiration Date 12/31/2020 Installation Instructions EL In L7QQAtrvLtiQn, fQr FBQ F6-pdf Verified By: Duc T Nguyen 65034 Created by Independent Third Party: No Evaluation Reports Created by Independent Third Party: 7006. 2 Hip and Ridge 12 Cap This is a 12" x 12" fiberglass asphalt shingle used to cover the hip and/or ridge of an asphalt shingle roof system manufactured at IKO's Kankakee, IL, Toronto, Ont. and Brampton, Ontario plants. Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes e Ieuler Approved for use outside HVHZ: Yes Surf iAud,it-1 Impact Resistant: N/A CA LtUEr A ]MD31 t l tt r 2 Design Pressure: N/A Other: 2 6 Quality Assurance Contract Expiration Date 12/ 31/2020 Installation Instructions FL? 006 R10 II Hi- an Re a ShM@,Le_1n2,tllhjion Instructions 1 2, FBC_FL7006f Verified By: Duc T Nguyen RE 65034 Created by Independent Third Party: No Evaluation Reports Created by Independent Third Party: 7006.3 1 Leading Edge Plus Asphalt Shingle One piece fiberglass asphalt shingle used as a starter strip at Starter Strip the bottom of a roof system manufactured in Brampton and Hawkesbury, Ontario plants Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes 2 .17 -fro FM._p If 912.) ...mm"-1. .9" Impact Resistant: N/A 1 F 1_7 ODL R A L Lt&r A TM 4 ter -_L-2 _L5 3 _-Q2_Lt, Design Pressure: N/A zaiiL2ff Other: EL- 7006 —P, I_Q_ -26- 4 'QlZl Quality Assurance Contract Expiration Date 12/31/ 2020 Installation Instructions instruction _L__ rFBCFL7, )j df i_ VerifiedBy: Duc T Nguyen PE 65034 Created by Independent Third Party: No Evaluation Reports Created by Independent Third Party: https:lllxA, w.floridabuilding.orolprl'Pr—at)i)—dtl.a,spx?param=wGEVXQxA,tDqse7mYBd2b-')K... 2/6/2018 Florida Building Code Online Page 3 of 3) Z: 7006A Marathon Plus AR, Superglass Plus 3 tab fiberglass asphalt shingle manufactured at IKO's AR Brampton, Ontario, Hawkesbury Ont., Toronto, Ont.; I I Sylacauga, AL and Kanakakee, IL plants Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes LehrfL7006R_LQ_C_CAC - SLtj I Q I .,Leje r -2-6 Approved for use outside HVHZ: Yes 2kj7jLrArn_FM )(ff Impact Resistant: N/A LJC106 P10 C CAIettr ASTMletter-_LL.,6- Design Pressure: N/A Other, E108"le'teE Quality Assurance Contract Expiration Date 12/ 20/2020 Installation Instructions Cf_ Li_ttuction fqr FB 1_70Q_opgf VerifiedBy: Duc T Nguyen 65034 Created by Independent Third Party: No Evaluation Reports Created by Independent Third Party: back Next C2_nja= : : nT J4LL19nt_t59-4U-I§l24 The State of Florida is an WEED employer, ri F1 ri - :: ftsy,n :: Ag,, Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a puNw-recordS request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. -pursuant to Section 455,275( 1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record, If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F, S., please click hlr&. Product Approval Accepts: MUMEEM D-eo"' CPFC1 Safe haps: //,ATNATw. florl dabui I ding. org/pr/pr_app_dt1. aspx?pararn=wGEVX QNNtDqse 7m YB d2b_3 ) K... 2/ 6/2018 d FGJTKB FA 1W TECH N O L O G U ES October 27.2O17 KOIndustries, Ltd 120Hay Rd. Wilmington, DE1Q8OS Sir(s). PRI Construction Materials Technologies has completed a technical review and attached sealed shingle instructions incompliance the 2O17Florida Building Code. This review was completed based on the receipt of following evidence from |K0 Industries, Ltd: 1) |K0 Shingle Application Instructions —3'Tab Shingles EN-3Tab_App|na_ 8AGXEFS-2812'11_vafonna ed 2013-U2-novU7/13-Florida) 2) |KOLaminskedShingles Application |na ruu1ionm EN'Laminated_App|ne_OTTEF8' 2012-04_refonnoMed2O13-U2'nav07/13'F|orida) 3) |KOHip and Ridge12App|icodun| nstru iona EN'HipondRidge12_3HRTri-2013-08_naformetted2013' 08) 4> |KOLeading Edge Plus Shingle Application Instructions EN-3LEP-Tri-2012-06_reforme#ed2013- 03) 5) ASTN1 O3181 Test Report (FM Approvals Project No. 3048947) The attached instructions should be used in conjunction with the published manufacturer's application instructions and applicable code. |nthe event the instructions conflict, these instructions shall govern. Statement of Independence: PR|Construction Materials Tech ies OucT.Nguyen, FLP.E.donot have nor plan to acquire a financial interest in any company manufacturing or distributing products for which the test reports are issued. Signed:Signed P. E. Number: 65034 Date: October 27.2O17 Date: October 27.2O17 Attachments: A)|KOShingle Application Instructions -3-Tab B)| KOLaminated Shingles Application Instructions C) |KO Hip and Ridge 12App|icsdion Instructions D)|KOLeading Edge Plus Application Instructions PRI Construction Materials Technologies, LLC. 64oBadger Drive Tampa, a33610Tel: ms-621/ 57777 Faximz-621-5840e-mail mate.daistesttng@pricrnt.com WethSilei hqp:Uww.pricmt.com mo Installation Instructions for Asphalt Shingles Page uu/o UKO Shingle Application Instructions _ 3-Tab Shingles NOTE: THESE INSTRUCTIONS SHALL BE USED IN CONJUCTN]N WITH |KO1S PUBLISHED APPLICATION INSTRUCTIONS AND THE APPLICABLE CODE. |NTHE EVENT THE INSTRUCTION CONFLICT, THESE INSTRUCTIONS WILL GOVERN. ROOF DECK: Solidly sheathed and fastened deck conforming ho2U17FBC UNDERLAYMENT: Applied in accordance with building code requirements. For areas where the roof slope is less than 4^ per foot down 0o2^ per foot, use 2 layers of underlaymend conforming to building code requirements, the first sheet overlapping the eave protection by 19", followed by full 36" widths overlapping each preceding course by 19" or other Approved underlayments in accordance with the qualified application instructions. For areas where the roof slope is 4^ per foot or greater, cover the deck with one ply of underlayment laid parallel to the eaves, with 2" horizontal laps and 4" end laps. Apply metal drip edges ontop of any underlay along rake edges and directly tothe deck along eaves in accordance with building code requirements. NAILING: Use galvanized (zinc coated) roofing nails, 11 or 12 gauge, with at least 3/8" diameter heads, long enough topenetrate through plywood or3/4''into boards. Use 4nails per shingle placed G-1/8^above the butt edge, approx. 1''and 13^from each end and 1/2^above each cutout. Drive nails straight oothat nail head ia flush with, but not cutting into shingle surface. NAILING ON STEEP SLOPES: For steep slopes of 21 " per foot (600) or more, use 6 nails per shingle placed anshown below. Ensure that nonail iawithin 2^nfajoint/cutout ofthe underlying shingle. Seal down each shingle at time of application with three 1" diameter (approx. size and thickness of a quarter) spots of asphalt plastic cement placed under the shingle 2" above the bottom edge and equally spaced along the shingle. Apply plastic cement in moderation since excessive amounts may cause blistering. CAUTION: Shingles should seal to the underlying course when the factory applied asphalt sealant is sufficiently warmed by the heat of direct sunlight. EXPOSURE: Installed shingles shall have maximum average exposure of5-5/ 8~ STEEP SLOPES SEALING STRIP NAILS— L NAILS DO NOT NAIL INTO OR ABOVE THE SEALING STRIP PRI Construction Materials Technologies, LLC, 6412 Badger Drive Tampa, a3361nTel. m3-621-5777 Faxms-5840 e-mail ,ph(.mt,com xo Installation Instructions for Asphalt Shingles Page omn UKOLaminated Shingles Application Instructions NOTE: THESE INSTRUCTIONS SHALL BE USED IN CONJUCT%]N WITH |KO'S PUBLISHED APPLICATION INSTRUCTIONS AND THE APPLICABLE CODE. |NTHE EVENT THE INSTRUCTION CONFLICT, THESE INSTRUCTIONS WILL GOVERN. ROOF DECK: Solidly sheathed and fastened deck conforming Vo2O17FBC. UNDERLAYMENT: Applied in accordance with building code requirements. For areas where the roof slope is less than 4^ per foot down to Z per foot, use 2 layers of underlayment conforming to building code requirements, the first sheet overlapping the eave protection by 19", followed by full 36" widths overlapping each preceding course by 19" or other Approved underlayments in accordance with the qualified application instructions. For areas where the roof slope is 4" per foot or greater, cover the deck with one ply of under| ayment|aidparoUe|totheeaves.vvith2''horizonta||apaand4''end|apa. Apply metal drip edges nntop of any underlay along rake edges and directly to the deck along eaves in accordance with building code requirements. NAILING: Use galvanized (zinc coated) roofing nails, 11 or 12 gauge, with at least%/8^diameter heads, long enough topenetrate through plywood or3/4"into boards. Use 4nails per shingle placed inthe nail line 7-3/8^ below the top edge, approx. 1''and 13^infrom each end. Drive nails straight oothat nail head ioflush with, but not cutting into shingle surface. NAILING DNSTEEP SLOPES: For steep slopes of21^ per foot (60')ormore, use Snails per shingle placed anshown below. Ensure that nonail iswithin 2^ofajoint/cutout ofthe underlying shingle. Seal down each ohingkaattimeofapp|inationwbhMhree1^diameter(approx.aizeendthicknesaofaquarter)apouofaapholt p|eaiio cement placed under the shingle 2" above the bottom edge and equally spaced along the shingle. Apply plastic cement in moderation since excessive amounts may cause blistering. CAUTION: Shingles should seal to the underlying course when the factory applied asphalt sealant is sufficiently warmed by the heat ofdirect sunlight. ' EXPOSURE: Installed shingles shall have maximum average exposure of 5-7Y8^ sm NAILING ' STEEP SLOPES APPLICATION Use six nalls as stlown, NAIL LINE PROPER APPLICATION REQUIRES THAT THE NAILS PENETRATE BOTH THE OVERLAY AND UNDERLAY PORTIONS orTHE SHINGLE PRImnsmjcijon Materials Technologies, LLC.w:zBadger Dnve Tampa, n113610 Tel 813-621-5777 Faxmz-621/5840 e- mail, WelhSite hnpJ/WWW,pncmt.com IKO Installation Instructions for Asphalt Shingles Page 4 of 5 IKO Hip and Ridge 12 Application Instructions ASTM D3161, Class F — IKO Hip and Ridge 12) NOTE: THESE INSTRUCTIONS SHALL BE USED IN CONJUCTIO.N WITH IKO'S PUBLISHED APPLICATION INSTRUCTIONS AND THE APPLICABLE CODE. IN THE EVENT THE INSTRUCTION CONFLICT, THESE INSTRUCTIONS WILL GOVERN. Cut hip and ridge shingles into thirds, using the perforation marks as a cutting guide. These shingles are designed for a 5 1/8" (130 mm) exposure. (For a neater appearance, the top of each side of each piece has been factory trimmed on a 1" (25 mm) taper (see drawing). Bend each piece over the hip or ridge, and nail 5 5/8" (143 mm) above the butt edge 1" (25 mm) in from each edge, exposing each piece 5 1/8" (130 mm). Apply hip pieces starting at the lower end of the hip, working up toward the ridge. On hip roofs, apply ridge pieces starting at each end, meeting in the middle. On gable roofs, apply ridge pieces starting at the end opposite to the prevailing wind direction and continue to the other end. Note: To obtain a three-dimensional effect, (which is recommended, but not required), apply hip and ridge shingles double thickness by stacking 2 pieces on top of one another, the lower piece extending about 3/4" (19 mm) further than the top piece (see diagram). The final shingle should be set in cement, and the exposed nail heads of the final shingle should be covered with cement. Prior to application in cold weather, storing the shingles in a heated area will allow for easier bending. NOTE: SHINGLES MUST BE APPLIED PROPERLY. THEY ARE DESIGNED FOR USE AS HIP AND RIDGE SHINGLES ONLY, AND SHOULD NOT BE USED FOR ANY OTHER APPLICATIONS. WE ASSUME NO RESPONSIBILITY FOR LEAKS OR DEFECTS RESULTING FROM POOR APPLICATION OR FAILURE TO PROPERLY PREPARE THE SURFACE TO BE ROOFED OVER, OR FAILURE TO PROVIDE PROPER VENTILATION IN ACCORDANCE WITH MINIMUM PROPERTY STANDARDS REQUIREMENTS. REVIEW ALL APPLICABLE BUILDING CODES, MINIMUM PROPERTY STANDARDS, AND REQUIREMENTS PRIOR TO APPLYING THESE SHINGLES USING THESE APPLICATION INSTRUCTIONS. TAPER CUT PRI Construction Materials Technologies, LLC. 6412 Badger pnve Tampa, FL 39610 Tel 813-621-57 7 Fax 813-621-5840 e-mail materialstesting@pricm,.com WebSite: http./twww.pnemt.eom mo Installation Instructions for Asphalt Shingles Page omo K U ~ Edge Plus U~t^K U t^nsLeadingApplicationInstructions ASTM D3161, Class F — IKO Leading Edge Plus) NOTE: THESE INSTRUCTIONS SHALL BE USED /N CONJUCTON WITH |KO^S PUBLISHED APPLICATION INSTRUCTIONS AND THE APPLICABLE CODE. IN THE EVENT THE INSTRUCTION CONFLICT, THESE INSTRUCTIONS WILL GOVERN. 1. Apply any underlayment, eave protection, valley flashings, or drip edges to roof deck as required, 2. Each 3Q3/8^x131/4"(1UOOmmx33Smm)|KOLeading Edge Plus strip ioperforated lengthwise for separation into two (2) shingles. Take one IKO Leading Edge Plus strip and fold flat at perforation to separate. 3, Take one ofthe separated shingles 3Q3/8^xG5/8''(1UO0mmx1G8mm)and remove approximately 20^(500mm). Install this shingle on the lower left corner of the roof deck, granule side up, with the factory installed sealant adjacent tnthe eaves. The shingle should overhang the rake edge and eaves byanominal 1/4^(Smm) minimum. Fasten the shingle tothe roof deck with nails located 3^to4^(75 mmto10Omm)from the eaveedge and 1^(25mm)infrom each end. 4. Take the leftover 20" (500 mm) piece shingle. Rotate the piece and align it vertically up the rake edge with the factory installed sealant adjacent Vuthe outer edge ofthe roof. The shingle should overhang thenakeedgebyanomina|1/4''(8mm)min|mum.Festentheshing|etotheroofdeokwithhastenena located 3^to4''(75mm0o100mm)from the rake edge and 1''(25mm)infrom each end. 5. Repeat Steps 3 — 4 for the right lower corner of the roof deck. NAILING: Use galvanized (zinc coated) roofing nails, 11 or 12 gauge, with at least 3/8(8mm)diameter heads, long enough hupenetrate through plywood or3/4"(2O mm) into boards. Use nails per shingle placed 3^1o4" (75 mmVo 100 mm)hnm the emveedge and approximately 1^and 18''(25mmand 33Omm)infrom each end. Apply full-length IKO Leading Edge Plus shingles to the remaining eave edges of the roof deck. Install the shingles granule side up with the factory applied sealant adjacent to the eaves. The shingles ahou|dovedhang1henskeadgeandeaveabyunomina|1/4^(8mm)minimum.Fastentheuhing|esto the roof deck with nails located 3" to 4" (75 mm to 100 mm) from the eave edge, 4 nails per shingle. 7, Apply roof shingles as per the instructions printed on each product's package. Make certain the first course of field shingle lies flush with the edges of the fastened IKO Leading Edge Plus. In this way, the sealant on the IKO Leading Edge Plus shingles will adhere to the first - course field shingles and help keep them from lifting inhigh winds. PRI Construction Materials Technologies, 12 Badger Drive Tampa, Ff- 3361uTel .mo-621/5777 Fax:m3- 621/5840 e-mail: Sile: http:1Www.pricmt.com Florida Building Code Online Page I of 2 8CIS Home Log In User Registration Hot Topics i Submit Surcharge Stats & Facts Publications FBC Staff 8CIS Site Map Links Search Product Approval0USER: Public User Lrp= AjbQMyt!, M&nji > Laqq, Ah i n 5g r h > jaLo in, s > Application Detail R 2" 12FL # FL15216-R3 Application Type Revision Code Version 2017 Application Status Approved Comments Archived Product Manufacturer InterWrap, Inc, Address/ Phone/Email 32923 Mission Way Mission, NON -US 00000 551) 574-2939 mtupas@interwrap. com Authorized Signature Eduardo Lozano elozano@interwrap. com Technical Representative Eduardo Lozano Address/ Phone/Email 32923 Mission Way Mission, NON -US 00000 778) 945-2891 elozano@interwrap, com Quality Assurance Representative Address/ Phone/Email Category Roofing Subcategory Underlayments Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed Robert Nieminen the Evaluation Report Florida License PE-59166 Quality Assurance Entity Intertek Testing Services NA, Inc, - QA Entity Quality Assurance Contract Expiration Date 09/30/2019 Validated By )ohn W. Knezevich, PE Validation Checklist - Hardcopy Received Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Sections from the Code FL112' 6E3_LQ)12 INip.rr:Lneja lff 514DAard ASTM D1970 (tear) ASTM D226 (physicals) Y- M 2015 2009 https: IIINIvw,V.floridabuilding.or&,Iprlpr_app_dtl.aspx?parana=xA,,GEVXQ"rtDqv' :),vVVKJZ 1Q... 21/6/2018 Florida Building Code Online Page 2 of 2 Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved ucts Method I Option D 10/10/2017 10/11/2017 10/15/2017 12/12/2017 FL # Model, Number or Name I Description I 15216.1 RhinoRoof Underlayments i Synthetic roof underlayments Limits of Use Installation Instructions Approved for use in HVHZ: No EL15216 R3 11 2017_1_Q FINAL ER INT_WRA P R Approved for use outside HVHZ: Yes B3_P_d_f Impact Resistant: N/A Verified By: Robert Njerninen PE-59166 Design Pressure. N/A Created by Independent Third Party: Yes Other: See ER Section 5 for Limits of Use. Evaluation Reports FL I - I I P _,APRHINOE0 SR2_pdf Created by Independent Third Party: Yes F —.C; I Next CRaM= z: 2601 Blair Stone Road, jaIl F }2394 ppq_n&_ -47- 4 The State of Florida is an AA/EEO employer. Copyright 2007-2013 ELL% i th m n Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850,487,1395, `Pursuant to Section 455.275(l), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emalls provided may be used for official communication with the licensee. However email addresses are public record. It you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please crick here . Product App al Accepts: M CJ qroEE M Gard Safe https:// wNvN,,,.floridabuilding.orgl/ r/pr_ap p dtl.aspx?i-n para=wGEVXQAlDqv'yVVKJZIQ... 2/6/2018 p EVALUATION REPORT nterwnaA|nc. 329Z3Mission Way Mission, 8CV2V-6E4 Canada 551) 574'2939 EXTERIOR RESEARCH & DESK]N,LLC. certificu, evfAvthoruoo^n#9BO3 353CHR| 5TiA0STREET, UNIT #13 OXFORD, [TO647 PHONE: (203) 2G2-9Z4S Evaluation Report 140510.02.12-113 FL1S216-R3 Date ofIssuance: O2/17/2U12 Revision 3:1O/ i0/2U17 5cops: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen' P.E. for use of the product under the Florida Building [ode and Florida Building [ode' Residential Volume. The products described herein have been evaluated for compliance with the Gm Edition (2017) Florida Building Code sections noted herein. Lxaeums: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. ownmuEuCoMpuxmoc;ThisEva| uadonReportisvaUdund| suchdmeasthenamedproduct(dchan#es.therefeoenced Quality Assurance documentation changes' or provisions of the [ode that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes orthe referenced Quality Assurance documentation changes, TrinitylERDrequires acomplete review ofthis Evaluation Report relative to updated Code requirements with each [ode Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity IERD Eva|uated^ maybe displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. wspecnow:Upon/equest'acnpynfthisentireEva|uationReportshaUbeprovidedtotheuserbythemanufactureror its distributors and shall be available for inspection atthe job site at the request of the Building Official. This Evaluation Report consists of pages I through 3. Prepared by: Robert J.M.Nieminen, P.E. Florida Registration No. f9166Florida D{AANE19Q3 The facsimile seal appearing was wthori2euby Robert wmminen.,c=mnouoz7 This does not serve aw electronically signed document, CERTIFICATION OF INDEPENDENCE: z. Trinity |sno does not have, nor does it intend to acquire or will it ucqv//e' a financial interest in any company manufacturing or distributing products it evaluates. z. Trinity |snois not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 1 xuucrt miemmen' p,c. does not have nor will acquire, a financial interest in any company manufacturing v,distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. s, This i,obuilding code evaluation. Neither T,mitY|snonor Robert w/emi^en. P.E. are, many way, the Designer ofRecord for any project on which this Evaluation Report, o,previous versions thereof, is/ was used for permitting o,design mv/duncc v^|eo retained TRINITY F ROOFING COMPONENT EVALUATION: Product Category: Roofing Sub -Category: Undedayment Compliance Statement: RhinuRoofUndedaymenta. as produced by |nten"mp^ Inc., has demonstrated compliance with the following sections of the 61h Edition (2017) Florida Building Code through testing in accordance with applicable sections of the following Standards, Compliance is subject to the Installation Requirements and Limitations / Conditions ofUse set forth herein. Properties Standard Year Unrolling, Breaking Strength, Pliability AsTwozze zoon Tear Strength AsTwoz97o zozs Examination Reference Date Physical Properties zuosagaescOc+noa 10/27/2011 Physical Properties 100539395cOQ-802 10/27/2011 Physical Properties 10053e39*[OQ-006 03/14/2014 AsTm oze7n;Tear strength Ocp-338'02-02 10/03/2017 Quality Control Service Confirmation 09/38/2017 4. 1 RhinoRoofV20 is mu|d|ayered polymer woven coated synthetic roof underlaymentavailable in 42-inch wide rolls, and can be produced in various other sizes; meets FBC 1507.1,1 (Exception). S. LIMITATIONS: SA This is building code evaluation. NeitherThnhyJERD nor Robert Nianinen' P.E. are, in anyway the Designer ufRecord for any project on which this Evaluation Report orprevious versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 52 This Evaluation Report isnot for use in FBCHVHZjurisdictions. . 53 Fie Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory or test report from accredited testing agency for fire ratings of this product. 5.4 RhinoRoufUndedaymems may be used with any prepared roof cover where the product is specifically referenced within F8Capp/ ova| documents. If not listed, a request may be made tothe Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering, 5.5 Allowable Roof Covers: TAsLE 1: ROOF COVER OPTIONS Underlayment Asphalt Shingles Nail - On Tile Foam -On Tile Metal Wood Shake Shingles Slate or Simulated Slate RhinoRoof U20 Yes NO No Yes Yes No 5.6 Exposure Limitations: RbiouRonfV20shall not beleft exposed for longer than 30-dayyafter installation. Exterior Research and Design, I.I.C. Evaluation Report wos1u.0z12-R3 Certificate o/Aumuri2am,o*yso o'~EDITION ( zon)Fecmom'*vxzEVALUATION pus216-n3 RhinoRoof uwwauvments xevuun3:1mu0/20zr Page xms 6. INSTALLATION: 6.1 RhinuRuof Unde1ayments shall be installed in accordance with |ntenm,up, Inc. published installation instructions subject tothe Limitations set forth inSection 5herein and the specifics noted be|mm. 62 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior tuapplication, 6.3.1 Shall be installed in compliance with the requirements for A5TM D226,Type | ovU undedaymentin FBC Table 1507.1. 1 for the type of prepared roof covering to be installed, taking into account the wider sheet - width fo'douWe-| ayerapp|icot|ons. 6.3.1 Fasteners: For exposure < 24 hours, corrosion resistant fasteners may be 1-inch roofing nails with a 3/8-inch diameter head, orthose noted inh.4lThe use ofstaples isprohibited. For exposure ,24 hours up to maximum 30da\a' corrosion resistant fasteners shall be minimum 1-inch diameter plastic or metal cap nails or FBC HVHZ nails & 1-5/8" diameter tin caps (with the rough edge facing up).The use ufstaples isprohibited, 632 Single Layer; Roof Slope > 4:12: End (vrdca|)laps shall beminimum 6-inchesand side (hohzonta|)laps shall beminimum 4-indhes. Refer to ntenwrap, Inc. recommendations for alternate lap configurations and/or the use of sealant under certain conditions. For exposure <J4 hours, use ofevery-other fastening location printed on the surface is acceptable. For exposure , 24 hours up to maximum 30'days, use of every fastening location printed on the surface is required. When batten systems are to be installed o*up the undedeyment, the vndedayment need only be preliminarily attached pending attachment ofthe battens onthe same day. Battens shall not bepositioned over cap nails. If this occurs, remove the cap nail and patch the hole in accordance with |ntenwrap published instructions. 6/i3 End (vertical) laps shall be minimum I2'inchesand side (horizontal) laps shall beminimumha|f-sheet+widrh p|ux1.inch. Double layer application; begin by fastening a half -width plus 1-inch starter strip along the eaves. Place a full -width sheet over the starter, completely overlapping the starter course. Continue osnoted in6.5'but maintaining minimum half -width p|vsI'inch side (horizontal) laps, resulting in a double -layer application. 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official orAuthority Having Jurisdiction in order to properly evaluate the installation of this product. Q. MANUFACTURING PLANTS: Qingdao, China QUALITY ASSURANCE ENTITY: END OFEVALUATION REPORT ' Exterior Research and Design, uc Evaluation Report wusx0.ozz2-ny Certificate^/Avm^nmnoo*eso oTIEDITION (zozr)mcwom'xvazEVALUATION puo/r,-ns xm*vnuvundenovm,m, Revision a.zu/1o/2uo Page yv/s Rhw R f' U20 VD{J U, i@YOOr_- Rhinu»Roof°U20UmstallationUmstructions RhinoRoof U20 is an air, water and vapor barrier and therefore must be installed above a properly ventilated space(s). Follow ALL building codes applicable toyour geographical region and structure type asitisconsidered avapor barrier, DECK PREP: Protrusions from the deck area must be removed and decks shall have no voids, damaged or unsupported areas. Deck surface should befree ofdebris, dry and moisture free. USE; RhinoRoof U2Umust hecovered byprimary roofing within 60 days of application. U28 is designed for use under; asphalt or synthetic sking|es, metal in residential applications, and cedar shakes that have been primed. APPLICATION: For slopes from 4:12and higher RhinoRuof U20istobelaid out horizontally (paraUe|)tothe eavewith the printed side up. Horizontal laps shcw| 6 be 4^ and Vertical laps should be 6^andanchored approximately 1^ in from the edge. For low slope applications it is recommended to overlap 50% plus l^, for complete definition of low slope and guidelines consult authorities having jurisdiction. U20 product isnot recommended for slopes less than 212. The use of roofing hammer, pneumatic air o/gas driven fastener tools is acceptable. The use u(straight edge cutting knives iarecommended. FASTENERS: For same day coverage with primary roofing RhinoRoof U2Ocan beanchored with corrosive resistant 3/8^ head x 1^ leg roofing nails (ring shank preferred, smooth leg accepta6|e).The use ofevery other anchoring location printed on the product is also acceptable, |fU2O will beleft exposed for upto6Odays the product must be anchored with 1^ plastic or metal cap smooth or ring shank roofing nails and anchored inall locations printed unthe facer. DDNOT USE STAPLES: the use ofstaples to penetrate RhinoRoof°U2Uwill void warranty. ANCHORING: All anchoring nails mum be Hush. 90 degrees ^othe roof deck, and tight with theundeHaymam surface and the structural roof deck, Where seams and joints require sealant o, adhesive use a low solvent plastic roofing cement meeting ASTk4D-4586Type 1.orFederal Spec SS- 153 Type 1 such as Karnak. Henry DAP, K4B. 6eoce| or equivalent. Acceptable alternatives are butyl rubber, urethane, and EDPk4based caulk ortape sealant. EXTENDED EXPOSURE: KRhinuRoof U20 product will beexposed longer than 246ours and uptub0days then product must be attacked to the structural roof deck using minimum 1^ 6iameterplastic ormetal cap roofing nails (ring shank preferred but smooth leg acceptable). Miami Dade approved tin tags/metal cops are also acceptable, and itisrecommended for best performance touse with the rough edge facing up. For extended exposure it is always recommended to anchor on every printed position on the facer, RhinoRoof~ U20 is not designed for indefinite outdoor exposure. For extended exposure conditions where driving rain or strong winds are expected it is recommended to take additional precautions such asdoubling the lap widths. Alternately o, in addition to a compatible sealant could beused between the laps orapeel and stick tape could 6eapplied zothe overlaps. CAUTION ' READ GOOD SAFETY PRACTICES BELOW Good safety practices should 6efollowed onsteep slope roofs, such asuse oftie-offs.toe boards, ladders and/or safety ropes and personal body harnesses. Follow OSHA guidelines. Slip resistance may vary with surface conditions from debris that accumulates, weather, footwear and roof pitch. Failure to use proper safety gear can result in serious irjury. Depending on roof pitch and surface conditions, blocking may berequired tosupport materials on the roof and is good safety practice. Remember to seal the nail holes after removing blocking. InterWrap" Roofing Products Division Charleston, SC ° Vancouver, ° Mission, BC ° k4nn a| { C Web: www.|nta60i-ap.com600fing / E-mail: in{o@intenwrapzum Florida Building Code Online Page I of 2 p, kffi"", A N f v1v{ bee 3 5CIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts I Publications FRC Staff f BCIS Site Map Links Search Product Approvaldb4- USER: Public Use, pr M&au > Pro a r qSign ah > Apgli i n t i i> Application Detail FL # FL16994-RS Application Type Revision Code Version 2017 Application Status Approved Comments Archived Product Manufacturer Address/ Phone/Email Authorized Signature Technical Representative Address/ Phone/Email Quality Assurance Representative Address/ Phone/Email Southeastern Metals Mfg. Co. 11801 Industry Drive Jacksonville, FL 32218 904) 696-4682 jhkelsey@semetals. com Jeremy Kelsey jhkelsey@semetals. coni Category Roofing Subcategory Roofing Accessories that are an Integral Part of the Roofing System Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed Zachary R. Priest the Evaluation Report Florida License PE-74021 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 12/20/2020 Validated By Locke Bowden Validation Checklist - Handcopy Received Certificate of Independence FL161)q4L R5 COI aLM1400I 5a ZO , B _Resort ff-_Rid 1j t 12-E--!: _qt tn find_ i.pdf Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Sections from the Code Product Approval Method 1503. 5 1709. 2 Method 2 Option B littps: I'IlNkr"-w.floridabuilding.orgllprlpr—app_dtl.aspx?parani=wGEVXQxA,tDqvBwyug,rrZN... 2/6/2018 Florida Building Code Online Page 2 of 2 Date Submitted 09/26/2017 Date Validated 10/10/2017 Date Pending FBC Approval 10/15/2017 Date Approved 12/12/2017 Summary of Products FL # Model, Number or Nam. Description 16994.1 Off Ridge Vent 4-ft, 6-ft, and 8-ft off ridge vents for use with asphalt shingles Limits of Use Installation Instructions Approved for use in HVHZ: No jj 6 Approved for use outside HVHZ: Yes Rid e Vent final. df Impact Resistant: N/A Verified By: Zachary P. Priest 74021 Design Pressure: +0/-18 Created by Independent Third Party: Yes Other: See evaluation report for limits of use. Evaluation Reports F _SEM14QOJ _-a_ Q_/1BC Eva[ ftUio_r_t Off_ to—OL.P.1t Created by Independent Third Party: Yes 16994.2 Tile Off Ridge Vent 4-ft, 6-ft, and 8-ft off ridge vents for use with clay or concrete the Limits of Use Installation Instructions Approved for use in HVHZ: No EL16994R. II SEMIA,QJ Sb 2L , FBC Eval RtQULTlle Approved for use outside HVHZ: Yes a.(zgf._ V§Lr)!_fia j.'p!f Impact Resistant: N/A Verified By: Zachary R. Priest 74021 Design Pressure: +0/-9 Created by Independent Third Party: Yes Other: See Evaluation Report for limits of use. Evaluation Reports 5b Roof Vent finaLDdf Created by Independent Third Party: Yes F.-.511 Nezt aauL :: 21 ,, n Ra T bh4uiLEL3,M Eh2m_k52_4U_1W4 The State of Florida is an AA/EEO employer. rZWjrLqh 7_ -A'l f Fl H tU4U_51ALqmg_n :: I h M n :: Bgty),Statement Under Florida law, email addresses are public records. If you CIO not want your e-mail address released in response to a public -records request, CIO not send electronic marl to this entity. Instead, contact the office by phone or by traditional mail. If you have any Questions, please Contact 850.487.1395, *Pursuant to Section 455.275(l), Florida statutes, effective Gct01)er 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an emav address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which Can be Made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click ttre Product Approval Accepts; M Z71 i9% : M Cre(JIT' Card Safe https:ll,Ar\N-A7.floridabuildiiig,orglprlpr_app_dtl.aspx?param=xA,GEVXQ\N-tDqx,BwYu9TrZN... 2/61/2 0 18 Certificate ufAuthorization No. 29824 W'** R N K17 2UEdin u hDr o Tampa, FL33S47 813) 480'342I EVALUATION REPORT FLORIDA Bu|Lo/maCODE, 6T"EDITION (2017) Manufacturer: Southeastern Metals Manufacturing Co.. Inc. (SEMCO) Issued October 10, 2017 11801Industry Drive Jacksonville, FL32218 800) 874-0835 Manufacturing Plant: Jaokannvi| le.FL Quality Assurance: ULLLC( OUA1743) Scops Category: Roofing Subcategory: Roofing Accessories that are anIntegral Part ofthe Roofing System Code Sections: 1503.5.1708 2 Properties: Roof Ventilation RErEnEwnss PRI Construction Materials Technologies ( TST5878) PRI Construction Materials Technologies (TST5878) Zachary R. Priest, P.E. ( CREEK Technical Services) PRODUCT DESCRIPTION Report No Standard Year Sew- 02e-02'01 ASTws000 201* sem-031'02*1 ASrwsnan 2014 aEM1*003 Calculations 2014 Off Ridge Vent: Minimum 2Oga. AGTMA7S2orA8TMAO53CSType 8etee Shall conform with F8C Section 1503.2 Maximum dimensions of the vent are 24-inch wide x 102+noh long x 425-inch high. Vent is available in nominal 4- ft, 6-ft and 8-ft sizes. This evaluation report mprovided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. LW1111111111110AIIARIA'''IN TECHNICAL SERVICES, LLC PRODUCT APPLICATION Southeastern Metals Manufacturing Co., Inc. Off Ridge Vent Deck Type: Minimum 7/15-inch APx span rated OSB sheathing or 15/32-inch APA span rated plywood sheathing for new and existing roof deck (Deck shall be designed by others in accordance with FBCmquirements). Roof slope: Minimum212 Installation Height: Maximum33-ft Roof Cut -Out: 2.5-inchwide x42-inohopening for the nominal 4-ftvent 2.5' inchwide x08-inokopening for the nominal 0-ftvent 2.5-inchwide x9O- inchopening for the nominal O-ftvent Attachment Method: Cut-out opening as prescribed above into the sheathing located a minimum 6-inch off the ridge For msingle vent, install the vent as close mthe center of the roof length as possible. Multiple vents should Ueevenly spaced along the roof length, Remove interfering shingle nails around the perimeter ofthe opening and any debris prior to placing vent, Apply ASTIM D 4586 or ASTN D 2409. Type | roofing cement/mastic to the underside of the perimeter flange to continuously surround and seal the flange. Position the vent over the opening inthe roof sheathing. Slide the top and side flanges of the vent underneath the shingles and allow the bottom flange to lie on top of the shingles. Attach the vent with or min, 12 ga. x 1-1/4-inch ring shank nails with min. 3/8-inch diameter heads having sufficient length mpenetrate through the sheathing aminimum of 3/8-inch. The fasteners shall belocated 1'inohfrom the edge ofthe flange and 55- inoheu oc. along all four sides ofthe vent. All loosened shingles shall be adhered down with roof cement/maatio, When nails are used toattach the vent, all penetraUonu through the vent flange shall be sealed using ASTIM D 4580 orA8TM D 3409. Type | mofingcement/mantio, Allowable Roof Coverings: Asphalt shingles Maximum Design 43.5msffor 4 and 6-ftvents Pressure 48poffor B-ftvent Pressures calculated using 2:1 margin of safety per 1504,9 This evaluation report isprovided for State mFlorida product approval "nue Rmea1szo'u, The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, mumoaoun, recommended use, mother product attributes that are not specifically addressed herein. Southeastern Metals Manufacturing Co., Inc. c muew Cw- TECHNICAL SERVICES, LLC LIMITATIONS 1) Fire Classification isoutside the scope ofthis evaluation, 2) This report isnot for use inthe MVMZ. 3) The roof deck and deck attachment shall be designed by others in accordance with the FBC, 4> SEMCO vents shall be installed in strict compliance with this evaluation report and the manufacturer's published installation instructions. |nthe event ofconflict, the more restrictive installation shall beenforced. 5) Deck substrates shall be clean, dry, and free from any irregularities and debris, All fasteners inthe deck shall bochecked for protrusion prior 0oinstallation. 0) Installation nfthe roof assembly iaoutside the scope ofthis evaluation. 7) SEMCO vents are intended tnprovide passive ventilation for unenclosed attic in residential construction applications 8) All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61G2O'3. COMPLIANCE STATEMENT The products evaluated herein by Zachary R. Priest, P. E. have demonstrated compliance with the Florida Building Code, 6th Edition (2017) as evidenced in the referenced documents submitted by the named manufacturer, o 701 41 n . x// s ucharyR. Pnes, P.E. Florida Registration No. 74O21 Organization No. ANE8641 Z CERTIFICATION opINDEPENDENCE CREEK Technical Servixes.uLC does not have, nor will uacquire, ofinancial interest many company manufacturing or distributing products under this evaluation. CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under this evaluation. Zachary n, pn=st. P.E. does not have, no, will acqwin,, wonarc/a/ interest in any company manufacturing or distributing pmmuuo under this evaluation. Zachary R, Priest, P.E. does not have, nor will -acquire, a financial interest in any other entity involved mthe approval process mthe product, END opREPORT This evaluation report mprovided for State uvFlorida product approval under Rule m820- z, The manufacturer shall notify CREEK Technical Services, uLCmany product changes mquality assurance changes throughout the duration for which this report is valid, This evaluation report does not express nor imply warranty, inmunmoon, recommended use, n,other product attributes that are not specifically addressed herein. MIAMI-DADS COUNTY MIAMI- PRODUCT CONTROL SECTIONa11805SW26Street, Room 208 DEPARTMENT OF REGULATOR17 AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786)315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) NN,xN NN.niiaiiiidade.goN-/econoniN, Southeastern Metals Manufacturing Company, Inc. 11801 Industry Drive Jacksonville, FL 32218 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER -Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been design ed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Weather Vent LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. Z-1 TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising, or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews and revises NOA No. 08-042' ).0 1 consists of pages I through 3. The submitted documentation was reviewed by Juan E. Collao, R.A. NOA No.: 13-0814.08 Expiration Date: 04/15/19 Approval Date: 01/23/14 Page I of 3 ROOFING ASSEMBLY APPROVAL Category: Roofing Sub -Category: Ventilation Material: Steel Minimum Slope: 2:12 TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED By APPLICANT: Manufactured bv Test Product Applicant Dimensions Specifications Description Weather Vent Vent: 4-1/2"x 1911 x 46" TAS 100 Galvanized metal roof vent Deck Flange: 24"x 52" Thickness: 0.0217 inch, MANUFACTURING LOCATION I. Jacksonville, FL EVIDENCE SUBMITTED Test Agency PRI Asphalt Technologies, IncZ: APPROVED APPLICATIONS: Test Identifier Test Name/Report Date TAS 100 SEM-002-021-01 08/14/03 ICC-ESAC132 SEM-027-02-01 01/07/14 Deck Type: Wood Deck Description: 15/- 2" or greater plywood or wood plank System Type A: Mechanical attachment of vent for shingle roofs Cutout: Mark a 31/2"x 46" opening centered between layout lines and aligned minimum 6 inches from the ridge. Set blade to thickness of sheathing and cut opening. Brush away sawdust and debris. Installation: Vents should be evenly spaced on the rear slope of the roof. Center vent in opening and set it in a 1/8" thick of an approved ASTM D 4586 asphalt roofing cement. Secure vent to the roof deck with 1-1/4" galvanized ring shank roofing nai-Is spaced approx. 8" o.c. and Y' from the outside edge of the flange. Use a minimum of 18 nails per vent. Seal all nails and vent flange with an approved ASTM D 4586 roofing cement. (See drawings herein). Net Free Area: 99 square inches. NOA No.: 13-0814.08 Expiration Date: 04/15/19 Approval Date. 01/23/14 Page 2 of 3 LIMITATIONS: 1. Refer to applicable building, code for required ventilation. 2. Weather Vent shall comply with the manufacturer's current published application instructions and the requirements set forth in the applicable building code. ZD 3. This acceptance is for installations over asphaltic shingle roofs only. 4. Weather Vent shall not be installed on roof mean heights greater than 33 feet. Z-1 5. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 9N-3 of the Florida Administrative Code. 6. All approved products listed herein shall be labeled and shall bear the imprint or identifiable marking of the manufacturer's name or logo, city, state, and following statement: "Miami -Dade County Product Control Approved" or the Miami -Dade County Product Control Seal as shown below: DRAWINGS 0 0 • ROOF FLANGE NAIL PLACEMENT 0 • END OF THIS ACCEPTANCE NOA No.: 13-0814.08 KmiAmi-DAIDE COUNTYM Expiration Date: 04/15/19 Approval Date: 01/23/14 Page 3 of 3 r -4, DESCRIPTION AS FURNISHED: Lot 34, WYNDHAM PRESERVE, cis recorded in Plat Book 81, Page-1 9,3 through 102 of the Public Records of Seminole County, Florida. BOUNDARY FOR/CERTIFIED TO: Park Square Enterprises, LLC (a Delaware Corporation); Winderweedle, Haines, Word & Woodman, PA; Attorneys' T,tle Insurance Fund; Bank of America LOT 49 LOT 50 AT 69'40'51 " E 40.00' 4J. I X 43. 13' LOT 34 6,7' 500' 44 5,00' CIO NOTE: Q-PLANS 0LOT35M=MEASUPED o LOT 33 FORM60ARD FOUNDATION FORMTOF- TOP OF FORM AVERAGE-30.54 6- 9.0 5.00' fn NOTE jPNSSURED 5,00' 25,20' 25.20' P.C. IV 89'4 0'51 " E 40-00' SLTRACKS AS FURNISHED FRONT - 2 F?F4& 211) SALTWARSHSIDE5' (40 LOT) LOOP 7.5 (60' LOT) PRIVATE ROAD (50' RIW) 10' (7-5' LOT) SIDE STREET - 25- (60'& 75- LOT) 1 5' (40' LOT) 25' FRONT SETBACK CAN BE REDUCED TO 20' ON CERTAIN LOTS. NO MORE THAN PLOT PLAN AREA CALCULATIONS 2) IN SUCCESSION AT 20' AND A MINIMUM OF (2) IN SUCCESSION AT 25' TOTAL LOT AREA 4.680 t SQUARE FEET PROPOSED - FINSHED SPOT GRADE ELEVATIONS F! TWORK ONIOFF LOT - TOTAL t SQUARE FEET FLAIWORK PER DRAINAGE PLANS SQUARE I, DRIVE 4031 110- 51.3 ± A FOUNDATION/PAD 1,195 t SOUARE FEE' E-- PROPOSED DRAINAGE FLOW WALKS 721200- 272 t SQUARE FEET RR PATIO 101 t SQUAIR'L, I FRONT PORCH DECK 48 1 '3-- 0UARI i i LOT GRADING TYPE A SOD 2,6451 130 - 2,975 ± SQUARE FEET I POOL DECK NIA 1 S00AW Ir' PROPOSED F.F, PER PLANS 30 5 NOTE: FRONT S(OCWALK AND MEET LOCA770M TAKEN FROM PLANS PRQV?2k 0By CUENT - NOT {TO vfPff,) CRUSEMWErER- SCOTT & ASSOC, INC -- S1JRVJr".r0R,-1- LANDLEV. D 5400 C. COLONIAL OR. ORLANDO, FL. 32807 (407)- 277-3232 FAX (407)--1 58-i4,36 PLAY VOL : HURT I LINE NOTES; 101 PIPE V- •- F(I.T TIT 1.1UPE I THE VNDMpRED OM HERE, CERTIFY WAI TIRS SURVEY WETS ME SFANOWPRACTICE SET FORK W D41, FLOPA A 4-0 M., OF C CURVATLFPC Gn "'CREIL —(. 1 .0. • — PoorrssPORAt, nOVEYORS ANTI MAPPERS MI CHAPTER 34-7 FLOWN AORVftS"MOVF CODE PURSUANT TO SECIVON 172,027, WWA S-ItS ZCT IV . ". 1., .1.1 4,% -1 - -M. 2. UNLESS EMBOSSED REM SURVEYOR'S S!ORATURC AND ORIGINAL RATS60 SEAL, MIS SURVEY 00 COPIES ME NOTT CD V1. - rTTRCS$ M r 01, T Or KG-I -c --Z 3 MS SURVEY OAS PREPARED YOU LRFORVAOON FURNISHED TO NE SURWYOR MCRE MAY ONFR RES-3 OR EASEMENTS THAT AFFECT MI5 PROPERLY 1C, POOF PEA-1 .111—C WMR,ENT 1.11IM rY, cw &c-llm M —V NO UNOEROROfMR - .. V. DM NAVE DEER 1"ITU UNLESS 17t,FRATSF INOVN W SURVEY' 6 PREPARED FOR W SW RENEW OF THOSEC"OFIED TO AND S- NOT W RFL,EU UPON6' Mr OVER 15 T- 6 4VWNSXNS O- FOR w U)CATTV, OF EN`N .W. — -1 w U14P 1. R(00,4 , Wwl -11 C"S" N RIK 7 QfARfNGS. ARC RASED ASSUMETI OA AND OP I- A SROW A$ SVSE RFAMNG (08) ITI UK 'E_ ELAVAMNS, IF OPI L ARC WED ON MThOPAL GCOOCOO OATUV Or 1429, URICSS ONC W5E NOOI) 9. OENTRTCAIE OF " S", vDFG VORD 'E110E IF kOD, I - 20-- 1 Or —.1, TPE FT ION, OF Iw- 64TE ORUFR No ms, DESCRIPTION ADtos URTIFTED ayPLOT PLAN 02- 41-2018 j 1098-8 REWSFO PLOT PLAN ( GRADES) 03-27-2018 FDR04SOARD ()UNOAT7O?J/ TLfW 06-27--201 1i4IS RUILD(NG\ PROPERTY WES NOT Uf wTHIN rtif, ESTABLISHED 100 YEAR FLOOD PLANE AS PER "FIRM' Tom X GRUSENMEYER, RL.5, 4714 DAMES W SCOTI R.L.S I 480T ZONE *X* MAP I 12117CO090 F (09-28-07) CITY OF SANFORD BUILDING & FIRE PREVENTION PERMIT APPLICATION Application No: Documented Construction Value: $ Job Address: J q o& ja/4 war a /-) p—C)DI9 Historic District: Yes F—] No Parcel ID: Residential.9--commercial Type of Work: New, .A.ddition Alteration Repair Demo Change of Use Move Description of Work: C,, Plan Review Contact Person: Title: Phone: Fax: Name Street: City, State Zip: E mail: Property Owner Information Phone: Resident of property?: Contractor Information Name _&I . 4.157 f> I Phone: 88 1 3 t U 4 a - Street: " ' _ Fax: City, State Zip:-f ,(i 0'C1 5,3 t1l3 _ State f.,icense No.: 4i f (( 5 q04? Architect/Engineer Information Name: Phone: Street: Fax: City, St, Zip: E-mail: Bonding Company: Mortgage Lender: _ Address: Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: 51" Edition (2014) Florida Building Code Revised: June 30, 2015 Pennit Application k QTICE: In addition to the requirements of this *permit, there may be additional restrictions applicable to this property that May liefoundinthepublicrecordsofthiscounty, andthere may be additional -permits _mquired from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, 1S713. The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required inordertocalculateaplan: review charge and will be considered the estimated construction value of the job at the time of submittal. TheactualconstructionvaluewillbefiguredbasedonthecurrentICCValuation.Table in effect at the time the perrhit is issued, in accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value, credit will be applied to your permit fees when the permit'is issued. OWNER' S AFFIDAVIT: I cc rfify that all of the foregoing information is accurate and that all work will be done in Cornplia"Ce With all applicable laws regulating construction an Signature of Owner/Agent Print Owner/Agent's Name Signature of Notary -State of Florida Date Owner/ Agent is Personally'Knowri to Me or Produced ID Type qf1l) Signature of ,. tary-state f I 1Date 0C dominisslon 0 GG15lair1707 Expires. October 15, 2021 U jw" ji-I 114 L bollUI" rjuContractor/Agentis7Pe sonallyKnown torr-WW' Produced ID Type tD- BELOW IS FOR OFFICE USE ONLY Permits Required. Building n Construction Type: . _ Total Sn Ft of Ido: Electrical WchanicalEl plumbingo GasE] Roof P Occupancy Use: Flood Zone: Min, Occupancy Load: 4- of Stories: New Construction- Electric - 9 of Amps Plumbffig -; # of Fixtures----. Fire Sprinkler Permit: Yes[] NoE!- # of Heads Fire Alarm Permit:. YesEl No 1.1 APPROVALS: ZONING: ENGINEERING: COMMENTS: Revised: June 30, 2015 UTILITIES: FIRE: WASTE WATER: BUILDlNG:___ Permit Application AGREEMENT A f NEW RESID,cX7141 CON 2$rgqCTION, WYNDHAM PRESERVE SERVICE PLAN SIZE SQ FT A/C SYSTEM PRICE SEBRING 200A 2410 10-kW HEAT 240V, 60A 6,758.00S-TON AC 240V, 50A SORRENTO 200A 2078 8-kW HEAT 240V, 50A 4-TON AC 24OV, 40A 5,465.00 SPRUCE 200A 2774 8-kW HEAT 240V, 50A w 7,264.004-TON AC 240Y, 40A SUNDANCE 200A 1730 5-kW HEAT 240V, 35A 5,081.003-TON AC 240V, 30A TELLURIDE 200A 2637 10-kW I IEAT 240V, GOA 5-TON AC 240V, 50A 6,601.00 TRIBECA 200A 1986 8-kW HEAT 24OV, 50A 4-TONZ(240V,OW' S,608.00 TUSCANY 200A 2718 10-kW HEAT 240V, 60A 6,818m5-TON AC 240V, 50A WALTON 11 200A 8-kW HEAT 240V, 50A 1811 4-TON AC 240V, 40A 5,110.00 WELLINGTON 200A 3075 QTY 2) 5-kW HEAT 240V, 35A 7,587.00 QTY 2) 3-TON AC 240V, 30A CONTRACTOR/OWNER: DATE: EDIVIONSON ELECTRIC: DATE: Skipper Road a Tampa, F 3 s Phone:(813)910-34 rax:(8 PLORIDA LICIME N V('13"549m MWWSW Y Cp,,y MEN7 7.- anaIF OemRe"Pt De - ouildl AUT" nRIZATIOt planviinandGfowtii. m Perl I altNo. CF, USE 0 V, se No I otal Code vlorid ------ job Site ' kadress ,' Me - City Discover Card ASA Date 11fxParatlanve of"Pa'YM'-nt 44, A 'off1he card) on the bvcodecl digits- 067 (Las elit cad) th Name as itappSTSantheeName (Pant ortype) cowyany d Cfhte City Fill not be, P110CP- sSed, CaTaolder ('-5igrO4ture aest M aft(VOT P iyments 10r your req q beCompletetochaTgefeesludingPCode, M" Is' illsboToav'b comw Sa" N-11 tbofj7'es 13CaTdboldej s cre(Etcarol- completed f 0-rp6yniits0 1 ppjjtablc to ri'c' JPTly ING I I -* -UR wry C' - " 0 M.-VO-I'LOV v 0 0,twf! 0N.'T CM ZJOA0 I -Y FAX -vo ) Iry ONL SOO) County . 64A-691- 3 county CUter S13 '214- 021 No.. 1::-4 SI3-635- 7361 (this number , Documented Construction Value: Job Address: 3J ok eg tP11 Historic District: Yes n No Parcel ID: Residential W CommercialEl Type of Work: New & AdditiouEl AlterationEl Repair 11 Demo El Change of Use El MoveEl Description of Work: Plan Review Contact Person: Phone: Fax: Email: Title: Property Owner Information Name Phone: Street: Resident of property? City, State Zip: Contractor Information Name Phone: Street: c Fax: City, State Zip: Ctc-d State License No.: I L Y Name: Street: City, St, Zip, Bonding Company: Address: Architect/Engineer Information Phone: Fax: E- mail: Mortgage Lender: Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. FRC 105.3 Shall he inscribed with the date of application and the code in effect as of that date: 5"1 Edition (2014) Florida Building Code Revised: June 30, 2015 Permit Application NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal. The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value, credit will be applied to your permit fees when the permit is issued. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Signature of Owner/Agent Print Owner/Agent's Name Date Signature of Notary -State of Florida Date Owner/Agent is — Personally Known to Me or Produced ID — Type of ID X, 11--__") Sig `lure 61 _ on t'o—r/Agent D e Print Contractor/Agent's Name x" N Signature of Notary State of F ofida Das" 7, Qn 8s5 "t7-) Contractor/Agent is Personally Knoil"O' i K' Produced ID Type of ID ST BELOW IS FOR OFFICE USE ONLY Permits Required: Btiilding[] ElectricalF1 Mechanica[E] PlumbingE] Gasn RoofEl Construction Type: Occupancy Use: Flood Zone: Total Sq Ft of Bldg: Min. Occupancy Load: # of Stories: New Construction: Electric - # of Amps Plumbing - # of Fixtures Fire Sprinkler Permit: Yes EJ No E] of Heads Fire Alarm Permit: Yes No APPROVALS: ZONING: UTILITIES: WASTE WATER: ENGINEERING; FIRE: BUILDING: COMMENTS: Revised: June 30, 2015 Permit Application Jot) kddre! Parcel ID: CITY OF SANFORD BUILDING & FIRE PREVENTION PERMIT APPLICATION Apptication No: Docurnented COnStl-LICtiOn Value: S Type of Work: Nei% 1-1 Addition " Alteration LJ Repair LL,!/:tvj FDescriptionofWork: - er kf*--h \1 !, r i /, irl I Plan RevieNN Contact Person: Historic District: Yes 1-1 No Residential ErcouicuercialEl Demo LJ Change of Use El NioN-e D I 11 IC Title: Pholle: Fax: — Email: Property Owner Information Street: Resident of property? City, State zip: Contractor Information 0 rNa1110 Phone: LJ`17-53;;,-, Street: Fax: v V-k—j (CC-v citv. State Zip: P fIt S t a t e 1, i C e r, S e \, o,: Architect/Engineer Information N, , .1111c: Street: Cit\.. St. zip: Boiidirio, Company: Fax: E-mail: Mort rate Lender: kddress: t\_NRNING TO OWNER: YOUR F A I U'RETO RECORD A NOTICE OF CON I) I ENCEN I ENT )I -k)' RESULT IN VOUR P.YING TW[CE I . OR IMPROVEMENTS U) YOUR PROPERTY. \ NOTICE Of-' CO) IML,\( N Nil -f- PIE RECORDED AND POS'VED ON -HIE jol,-, SITE III.'J-O[E '1'1117 FIRST INSPECTION. It: YOU VVI END 10 OjjT-kj\ FINAACING, CONSI-J'"I, NUIJI YOUR LENDER OR AN ATTORNEY BE -FORE RECORDING 1OUR, No'FICE OF CONIVENCEME,N]" I lillderstand that n separatt, [Ilet-11lit TTILIsl be secured for electrical \Niwk, phl I'llo ill'—'. pools. ftlrn.aco, boilers. heaters, tallks, and air conditioners, etc, H,,( I Os.3 Iljll tic in,crillcd \t ith I (LOQ ot, application and Ilan code in 0—."o :.- of twat djtv: [dition I Florilj uild , in,_, YFICT-: In addhon to On requirements of this pci-n-ut. may bz- additional applicable to this propeny War may beWindinMepublicmucordsofthisco,"ItY, and th.,ve ma be adJnKMaI P4Tulits r0quu;d fro-ni 0-horgoverain nnial eado es such as qyapc man,agemenz districts, we agenct s. or federal agencks, I Acceptance of peril k veritkation that I will nowf, th-' WVncr Of thProperry of Me refer mews of F&Hda Len Lav FS 713. Tll;, City of, San"'ord requlrts rayrneill of a plan r n iN fee an W thic of p2nK subnhaaL A c(lo oC the executed Contrast is required n osier to calculaw a plan Wept chu,mv and mill be considered On estiniawd construction value of We job at the time of p,iiral The I a",tual tonsil action Nukegill be Qued hoed on to cuu=1 ICC Aluation Tabl, in effect at the time the perruit is iss'-%'d, in accordance Wth Kcal ordma:we Should calculwcd chutes figumd offle exzcu'Md cod-iITacl exceed the actual convincoon valuo, credit "Al be applied to YOU PMKE fees Olen to permit is issued, OWNER'S AFFIDANIT: I certify that all of the foregoing information is accurate and that all work Nvill be done in compliance with all applicable lams regiihatino Construction aad--7, n, Dm Owner A2,-nt is Pet-sonali", Kno% vi", to \I,- c"T, Produced ID J)-pof ID Rqww-, Pnw cw Contravor'Agent is " Personal, Qown to Nle or Produc.d ID T pof ID BELONVIS FOR OFFICE USE ONLY EJ iH] a D o Permits Required: ElP ILl G R ol Construction Type: OCCLIPancy Use: Flood Zone: Toot Sq Ft of BW Min. Occupancy Load: = of Stories: NeNN Construction: Electric - # ofA1111-is PkuubWg - 5 of Fixtures We Sprinkler Perruit: Yes of hens - —111-1-1-- Fire Alarni llerniit: Ni'es F N,)[] APPROVALS 7C)Nl'\ J): UTILIVES: WASTE WATER: l-NUNFFRTNG: C 0 \ I I F. NT S : FIRE: I:')!,- I L D I NG: City of Sanford Building & Fire Prevention Division 300 N. Park Ave Sanford, FL 32771 To Whom It May Concern: Please be advised that Edmonson Electric has been released from the following permits: 18-0741 - 3924 Night Heron Drive 18-1392 - 3917 Saltmarsh Loop 18-1265 - 3908 Saltmarsh Loop 18-1473 - 3905 Saltmarsh Loop The new contractor is Strada Electric. Please let me know if you need anything else to resolve this matter. I can be reached at 407-529-3163 or tpickerinq@parksguarehomes.co,m - Thank you for assistance with this matter. Sincerely, 21 a PickeringPermitting Coordinator, Park Square Homes 6 n _ i — o w —I ' -"k" _ ! I. `or c: . .: 407 529 3000 -, % 0 7 529 3 100 ; :A- :', 1 0 r Job Address: 3908 Saltmarsh Loop CITY OF SANFORD BUILDING & FIRE PREVENTION PERMIT APPLICATION Application No: I Documented Construction Value: $. 6398.00 Historic District: Yes [I NoEl Parcel ID: —17-20-31-502-0000-0340 Lot 34 Residential E Commercia][] Type of Work: New E AdditionEl AlterationEl RepairEl DemoEl Change of Use El Move 11 Description of Work: Install new 3.0-ton HVAC system with duct work Plan Review Contact Person: Paula Bagley —Tifle: Permit Clerk Phone: 4Q7-975-2762 Fax: 4Q7-629-25QZ Email: permittin2!2onestopcoolin2.corn Property Owner Information Name Park Square Homes Phone: 407-529-3000 Street: 5200 Vineland Rd #200 Resident of property? City, State Zip: Orlando, FL 32811 Contractor Information Name One Stop Cooling & Heating, LLC Phone: 407-975-2762 Street: 7225 Sandscove Court Fax: 407-Q29-93Q7 - City, State Zip: (inter Park.. FI .497C)9 State License No.: CAC 032444 Architect/Engineer Information Name: Street: City, St, Zip: Bonding Company: Address: Phone: Fax: E-mail: Mortgage Lender: Address! WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. FBC 105.3 Shall be inscribed with the date of application and the code In effect as of that date: 5'^ Edition (2014) Florida Building Code Rcvised: June 30, 2015 permit Application 1b NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of it plan review fee at the tune of permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal. The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value, credit will be applied to your permit fees when the permit is issued, OWNER'S AFFIDAVIT: I certify that all of the fore ping information is accurate and that all work will be done in compliance with all applicable laws rq xn and zoning. til1 4` gistructir Signature of0wrier/Agent Date 4--Wllre of Print Owner/Agent's Name Signature of Notary -State of Florida Date Owner/ Agent is — Personally Known to Me or Produced ID — Type of ID 1 4 e 7/5/18 Kevin Stine Print Contfactor/Agent's Name Signature KELLY WEBSTER Notary Public - State of Florida Commission # FF 978034 My Comm. Expires Apr 4, 2020 Produced ID Type of ID BELOW IS FOR OFFICE USE ONLY Permits Required: Building D Electrical n Mechanical [] PluirlbingFl GasE] Roof [] Construction Type:_ Occupancy Use: Flood Zone: Total Sq Ft of Bldg: Min. Occupancy Load: New Construction: Electric - # of Amps Fire Sprinkler Permit: Yes ] No P It of Heads APPROVALS: ZONING: UTILITIES: ENGINEERING: FIRE: X43011107100 of Stories: Plumbing - # of Fixtures Fire Alarm Permit: YesE] No] WASTE WATER: BUILDING: Revised: June 30,2015 I'vinit Application DESCRIPTION AS FURNISHED: Lot 34, WYNDHAM PRESERVE, as recorded in Plot Book 81, Pages 93 through 102 of the Public Records of Seminole County, Florida. BOUNDARY FOR/CERTIFIED TO: Park Square Enterprises, LLC (a Delaware Corporation); Winderweedle, Haines, Word & Woodman, PA; Attorneys' Title Insurance Fund; Bank of America LOT 49 SET 112" LR. t ON 459 6 LIN LOT 50 AT 89040'51 " E Pvc 40.00' SET 112 I.R, ENCE OFF # 4596 H el-' LOT 35 5, DO' 5.00' Qo Q) SETBACKS AS FURNISHED FRONT - 2'(*) REAR 20 SIDE = 5' (40' LOT) 7,5' (60' LOT) 10 - (75' LOT) SIDE STREET - 25' (60' & 75' LOT) 15' (40' LOT) 25' FRONT SETBACK CAN BE REDUCED TO 20' ON CERTAIN LOTS. NO MORE THAN 2) IN SUCCESSION AT 20' AND A MINIMUM OF (2) IN SUCCESSION AT 25' PROPOSED = FINSHED SPOT GRADE ELEVATIONS PER DRAINAGE PLANS SET N&D 4596 43,13' 4113' 43.13' LOT 34 3.5'x3.5' AC PAD 1:1 13.3' 16.7' COVD. DO BRICK 06 13.3' 25.20' 0'2' ON TWO STORY RESIDENCE F.F.= 30,62' 9.0' 1 CQVT BRICK BRICK WALK BRICK DRIVE 25,20' V I 1 —0' U -T1 L E—S M 5' CONC. WALK AT 89040'51 " E (B.B.) 40.00' 5.00' 4 o LOT 33 Q3 Cf) 5.00' aoo' P' SET N&D 4596 SAITHARS-11 LOO.-P PRIVATE ROAD (50' RIW) PROPOSED DRAINAGE FLOW vo LOT GRAOING TYPE A PROPOSED F.F. PER PLANS - 30.5' CRUSEjVffEYER —SCOTT ASSOC, INC.— LAYV-D SURVE17ORS LEGCND - LEGEND - P PLAT P11L. POINT ON LINE 5400 E. COLONIAL DR. ORLANDO, FL. 32807 (407)-277-3232 FAX (407)-658-1436 F FIELDCLD TYP. TYPICAL NOTES: ip. P_ IRON PIPE PR,C' P C4. POINT OF REVERSE CURVATURE POINT OF COMPOUND CURVATURE 1 THE UNDERSIGNED DOES HEREBY CFRITFY THAT THIS SURVEY WEFTS THE STANDARDS OF PRACTICE SET FORTH BY THE FLORIDA OWC, or C,M, CON"CRRITC MONUMENT RAD' RADIAL PROFESSIONAL SURVEYORS AND MAPPERS IN CHAPTER 5J-17 RORIDA ADMINISTRATIVE CODE PURSUANT TO SEOPON 472.027, FLORIDA STATUES SET LIT, 1/2' I.R. •/OLD 4596 RR. NON -RADIAL 2. UNLESS EMBOSSED WITH SURVEYORS SIGNATURE AND ORICiNAL RAISED SEAL, THIS SURVEY MAP OR COPIES ARE NOT VALID. RERECOVERED V.P. WITNESS POINT 3. THIS SURVEY WAS PREPARED FROM ME INFORMATION rURNISHF0 TO THE SURVEYOR. THERE k4Y HE 0771ER RESTRICTIONS P.O.B.BP.Q.C. POINT OF BEGINNING POINT OF COMMENCEMENT CALC R.R'N CALCULATED PER MANENT REFERENCE MONUMENT OR CASCA400S THAT AFFECT THIS PROPERTY. 4, NO UNDERGROUND IA4PR,'WE'X'ENTS HAVE BEEN LOCATED UNLESS OTHERWISE SHOWN, N&D CENTERLINE HAIL & DISK F.F. B.S.L. FIN (HETT FLOOR ELEVATION BUILDING SETBACK LINE 5. THIS SURVEY IS PREPARED FOR THE SOLE BENEFIT OF THOSE CERTIFIED TO AND SHOULD NOT BE REUEO UPON BY ANY OTHER NTTrY. R/W RIGHT-OF-WAY BENCHMARK 6. VIA1&NS*NS SHOWN FOR THE LOCA770M OF IMPROVEMENTS HEREON SHOULD NOT BE USED rO RECONSTRUCT BOUNDARY LINES, ESMLGRAIN, DASEHENTCRAINAGE BKB WE REARING 7. BEARINGS, ARE RASED ASSUMED DATUM AND ON THE LINE SHOWN AS WE NEARING (B.B.) UTII, U TILITY 8. ELEVATIONS, IF SHO0,'. ARE WED ON NATIONAL GEODETIC VERTICAL DATUM OF 1929, UNLESS OTHERWISE NOTED, CLFC, CHAIN LINK FENCE 9. ^ERTIFICAiT' OF AUTHORIZATION No. 4596. WDfC, C/oP.C. WOOD FENCE CONCRETE BLOCK POINT OF CURVATURE SCALE DRAWN BY: evA20 P.T. DESC. POINT OF TANGENCY DESCRIPTION CERTIFIA'3 BY. DATE No, RL RADIUSARCLENGTH PLOT PLAN 02-23-2018 1098-18 D DELTA REVISED PLOT PLAN (GRADES) 03-27-2018 1CC .B' CORDBEARING FORMBOARD FOUNDATIONIELEVS. 06,-27-2018 4237-18 NORTH FINALIELEVS. 01-08-2019 190-19 THIS BUILDING\PROPERTY ooEs NOT UE WITHIN THE ESTACILISHEO 100 YEAR FLOOD PLANE AS PER 'FIRM" M. nGWUIEVER,R, 3 4714 SCO ,'L ZONE X. MAP f 12117CO090 F (09-28-07) 401 15 lightyears, Inc 15 lightyears 776 Bennett Drive Longwood, Florida 32750 June 1, 2018 To: Local Building Department RE: Blower Door Test & Duct Leakage Test Reports To whom it may concern, This letter is to request that the attached forms be accepted for compliance of the 2017 Florida Building Code statute R402.4.1.2 Envelope leakage testing (Blower Door Testing) and R403.3.3 Duct testing. The attached forms were provided by the Florida Building Commission as the accepted forms to be submitted. These forms are listed on the 2017 Florida Building Code, Energy Conservation Technical Assistance Manual, Document Number: TAM-2017-1.0, released February 02, 2018, pages R-78 through R-80 (page numbers 159-161). Web link provided for quick access to the TAM document https:/Itinyuri.com/2017FBC-TAM These forms meet all three required Residential Energy Efficiency Compliance Paths listed under R401.2, Prescriptive, Performance, and Energy Rating Index (ERI) paths. We are working with building departments across Florida to standardized the form submittal process and would like your department to allow these forms to meet compliance. If there are any issues with accepting these forms, please reach out to me directly and I will ensure that we submit any specific form that you will require. Tim Smith (407)-951-3236 tsmith@151ightyears.com Respectfully, Timothy With 15 Lighlyears, Chief Operations Officer Energy Technical Advisor RESNET Quality Assurance Designee IECC Residential Energy Inspector/ Plans Examiner Member, Building Officials Association of Florida Member and Code Development Committee participating member. Also, representative to the Florida Building Commissions, Energy Technical Advisory Committee for the BOAF- CDC tnvelope Leakage Test Report (Blower Door Test) Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Ijurisdiction: Permit#: job Information Builder: ccc_r Community: Ot-) Lot: Address: „ (_vc Unit: J City: r Cl State: zip: Air Lea kaize Test Results Passing results must meet either the Performance, Prescriptive, or ERI Method 0 PRESCRIPTIVE METHOD- The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g. (50 pascals) in Climate Zones 1 and 2. G40ERFORMANCE or ER1 METHOD. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50) value, as shown on FORM R405-2017 (Performance) or R406-2017 (ERI), section labeled as Infiltration, sub -section ACHSO. ACH(50) specified on Form R405-2017-Energy Calc (Performance) or R406-2017 (ERI): 1(ez& Z x 60 = CFM(50 Building Volume ACH(50) 0 Retrieved from architectural plansPASSMechanicalVentilationisnotrequired) (4.<b'de software calculated PASS (with Mechanical Ventilation) 0 Field measured and calculated FAIL R402.4.1.2 Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure or 0.2 inch w.g. (50 Pascals). Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statues, or Individuals licensed as set forth in Section 489,105(3)(f), (g} or (1) or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code officlat Testing shall be performed at anytime after creation of all penetrations of the building thermal envelope. During testing: 1,Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or other infiltration control measures. 2,Dampers including exhaust, intake, makeup air, back draft and flue dampers shall be closed, but not sealed beyond intended infiltration control measures, 3.Interior doors, if installed at the time of the test, shall be open. 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. S.Heating and cooling systems, if installed at the time of the test, shall be turned off. 6.Supply and return registers, if installed at the time of the test, shall be fully open, Testing Company Company Name: 15 Lightyears , Inc Phone: (855)438-1515 1 hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements a ing to the ce method selected above. Signature of Tester: Date of Test: Printed Name of Tester: Agrgn Qverbolt License/ Certification #: 2QN813Z Issuing Authority: BESNET Copy of License / Certificate of the tester must be attached) ME= Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Ijurisdiction: Permit #. Job Information Builder: Community: Lot: Address: (+ Unit: City: State: Zip: 32--7 -73 Duct Leakage Test Results System 1 cfm25 System 2 cfm25 System 3 cfm25 Sum of any additional systems cfm25 Total of all systems cfm25 0 Prescriptive Method cfm25 (Total) To qualify as "Substantially leak free" Qn Total must be less than or equal to 0.04 if air handier unit is installed. If air handler unit is riot installed, Qn Total must be less than or equal to 0.01 This testing method meets the requirements in accordance with Section R403,33. 15 the air handler unit installed during testing? F] YES E]NO Performance ERI Method cfm25 (out or Total) To qualify using this method, Qn must not be greater than the 1-141 + rno Qn proposed duct leakage Qn specified on Form R405-2017 or R406-2017. Total of all Total Conditioned Leakage Type selected on Form Qn specified on Form R405-20 7 7 systems Square Footage R405-2017 (Energy Colc) or R406-2017 (Energy Cale) or R406-2017 2VASS 3 Duct tightness shall be verified by testing in accordance with ANSI/RESNET/ICC380 by either individuals as defined in Section 553.993(5) or (7), Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(f), (g) or (i), Florida Statutes. Testing Company Company Name: 15 Ligh!years , Inc Phone: (855) 438-1515 1 hereby verify that the above duct leakage testing results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements 9g4Qrdjng to the ce method selected above. Signature of Tester: Date of Test: Printed Name of Tester: Aaron Overholt License/ Certification #: 2DNAB7 Issuing Authority: R FRN E I Copy of License / Certificate of the tester must be attached) Certificate o Achievement THIS ACKNOWLEDGES THAT Certification Date: 08/07/2018 Certification Expires: 08/07/2021 i ilk] a I a w4 U MA ": Tim Smith, RESNET Quality Assurance Designee 1~ 15 e a RESNET QA Provider # (1998-199)