Loading...
3733 Hanworth Lp 18-2854; NEW SFHCOUNTY OF SEMINOLE IMPACT FEE STATEMENT STATEMENT NUMBER: 18100005 BUILDING APPLICATION #: 18-10000586 BUILDING PERMIT NUMBER: 18-10000586 DATE: July 02, 2018 1 dlxSLf a]-!; f i UNIT ADDRESS: HANWORTH LOOP 3733 17-20.31-5VC-0000-0280 p I TRAFFIC ZONE:022 JURISDICTION: O l SEC: TWP: RNG: SUF: PARCEL: SUBDIVISION: TRACT: PLAT BOOK: PLAT BOOK PAGE: BLOCK: LOT: OWNER NAME: ADDRESS: APPLICANT NAME: NVR INC. DBA RYAN HOMES ADDRESS: 4307 VINELAND ROAD SUITE H-20 ORLANDO FL 32811 LAND USE: SINGLE FAMILY RESIDENCE TYPE USE: WORK DESCRIPTION: CITY-SANFORD SPECIAL NOTES: 3733 HANWORTH LOOP / KENSINGTON RESERVE SFR FEE BENEFIT RATE UNIT CALL UNIT TOTAL DUE TYPE DIST SCHED RATE UNITS TYPE ROADS-ARTERIALS CO -WIDE ORD Single Familyy ROADS -COLLECTORS Housing 705.00 1.000 dwl unit 705.00 Single Family N/A Housing 00 1.000 dwl unit 00 FIRE RESCUE N/A LIBRARY CO -WIDE ORD 00 Single Family SCHOOLS Housingg 54.00 1.000 dwl unit 54.00 Family CO -WIDE ORD Housing 9,000.00 1.000 dwl unit 91000.00PASingle LAW ENFORCE N/A 00 DRAINAGE N/A 00 00 AMOUNT DUE 9,759.00 PERSONS ARE ADVISED THAT THIS IS A STATEMENT OF FEES DUE UNDER THE SEMINOLE COUNTY ROAD, FIRE/RESCUE, LIBRARY AND/OR EDUCATIONAL ISSUANCE OF A BUILDING PERMIT. PERSONS ARE ALSO ADVISED THAT ANY RIGHTS OF THE APPLICANT, OR OWNER, TO APPEAL THE CALCULATION OF ANY OF THE ABOVE MENTIONED IMPACT FEES MUST BE EXERCISED BY FILING A WRITTEN UEST WITHIN 45 CALENDAR DAYS OF THE DATE ABOVE BUT NO LATER TM CERTIFICATE OF OCCUPANCY OR OCCUPANCY. THE REQUEST FOR REVIEW MUST MEET THE REQUIREMENTS OF THE COUNTY LAND DEVELOPMENT CODE. COPIES OF RULES GOVERNING APPEALS MAY BE PICKED UP, OR REQUESTED, FROM THE BUSINESS OFFICE: 1101 EAST FIRST STREET, SANFORD FL, 32771; 407-665.7356. PAYMENT SHOULD BE MADE TO: SEMINOLE COUNTY OR CITY OF SANFORD BUILDING DEPARTMENT 1101 EAST FIRST STREET SANFORD, FL 32771 PAYMENT SHOULD BE BY CHECK OR MONEY ORDER, AND SHOULD REFERENCE THE COUNTY BUILDING PERMIT NUMBER AT THE TOP LEFT OF THIS STATEMENT. THIS STATEMENT IS NO LONGER VALID IF A BUILDING PERMIT IS NOT ISSUED WITHIN 60 CALENDAR DAYS FROM THE DATE ABOVE REQUEST FOR TUG & PREPOWER AGREEMENT J ALL RESIDENTIALTROPERTIES Altamonte Springs, Casselberry, Longwood, Oviedo, Sanford, Seminole County, Winter Springs Date Project Name: Kensington Reserve Project Address: Ha,4ti-x3,,A I-6LY,,0 Building Permit #: Electrical Permit # T In consideration for authorizing the appropriate utility company to energize the facility, we agree with and understand the following: 1. This Tug/Pre-power application is valid only for one -and two-family dwellings. 2. The facility will not be occupied until a certificate of occupancy has been issued. 3. If the jurisdiction hereafter finds that the facility has been occupied before a certificate of occupancy has been issued, the jurisdiction will have the unilateral right to direct the utility to terminate electrical service without notice. Furthermore, we understand and agree that should the jurisdiction exercise such right, the jurisdiction will not be responsible for any damages or costs which may result from the exercise of such right. Also, in the event any third party claims damages from the exercise of such right, we agree to jointly and individually indemnify and hold harmless the jurisdiction from all such damages and costs, including attorney's fees. 4. Prior to pre -power, the building or structure shall be weather tight and secure. The electrical wiring in the area designated for pre -power shall be complete and in safe order. All electrical services associated with the area will be 100% complete unless specifically approved by the electrical inspector. S. Interior electrical rooms shall be lockable, if electrical panels are in an area that cannot be locked by doors, the panels shall be equipped with a locking mechanism (approved by the AHJ). The licensed electrical contractor or his licensed representative shall hold the keys(s) for such access to electrical panels to prevent energizing circuits other than those that are safe. 6. This TUG/Pre-power approval is valid for a maximum of 180 days from date of approval. 7. If provided, the fire sprinkler system must be operational with water on the system prior to pre -power. S. TUG approval is for service and outside GFCI outlets only. 9. Check with the local jurisdiction for fees associated with tugs. Robert Lattanzi - Ryan Homes Print Name f Owne /Ten Signature of er/Tenant JURISDICTION EMPLOYEE NAME: JURISDICTION: CALLED INTO: Rev. 02/+10/15) 1 Robert Lattanzi - Ryan Homes Print Nam en. Co tra Signature of Gen. Contractor CBC 1257565 Gen. Contractor License # Scott L Easterbrook - Palmer Electric Print Name of El. Contractor ignature of El. Contractor EC0003096 El. Contractor License # Progress Energy Florida Power and Light on / Grant Maloy, Clerk Of The Circuit Court & Comptroller Seminole County, FL Inst #2018098861 Book:9200 Page:912; (1 PAGES) RCD: 8/27/2018 12:50:33 PM REC FEE $10.00 THIS INSTRUMENT PREPARED BY: Name: NVR Inc. dba Ryan Homes r7t-rt r, Address: 4307 Vineland Rd, Suite H-20 Orlando FL 32811 NOTICE OF COMMENCEMENT Permit Number: 18-2854 Parcel ID Number: 17-20-31-5VC-0000-0280 D CCPV l'irr—' f qc U., t .. AUG.27 2018 The undersigned hereby gives notice that Improvement will be made to certain real property, and In accordance with Chapter 713, Florida Statutes, the following Information Is provided In this Notice of Commencement. 1. DESCRIPTION OF PROPERTY: (Legal description of the property and street address If available) Lot # 28 of Kensinqton Reserve 3733 Hanworth Loop 2. GENERAL DESCRIPTION OF IMPROVEMENT: Construction of Single Family Home Residential 3. OWNER INFORMATION OR LESSEE INFORMATION IF THE LESSEE CONTRACTED FOR THE IMPROVEMENT: Name and address: NVR Inc. dba Ryan Homes- 4307 Vineland Rd, Suite H-20 Orlando FL 32811 Interest In property: Fee Simple Title Holder (if other than owner listed above) Name: NA Address: 4. CONTRACTOR: Name: NVR, Inc dba Ryan Homes Phone Number: 407-692-9820 Address: 4307 Vineland Rd, Suite H-20 Orlando FL 32811 6. SURETY (If applicable, a copy of the payment bond Is attached): Name: NA Amount of Bond: 6. LENDER: Name: Phone Number: Address: Persons within the State of Florida Designated by Owner upon whom notice or other documents may be served as provided by Section 713.13(1)(a)7., Florida Statutes. Name: Dayna Mitchell Phone Number: 407-692-9820 Address: 4307 Vineland Rd Suite H-20, Orlando FL 32811 8. In addition, Owner designates to receive a copy of the Llenor's Notice as provided In Section 713.13(1)(b), Florida Statutes. Phone number: 9. Expiration Date of Notice of Commencement (The expiration Is 1 year from date of recording unless a different date Is specified) WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART I, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. Dayna Mitchell Assistant Secretary 519naLuiyof Owner or Lessee, or Owners or Lassoe' (Print Name and Prmlda signatory's Tide/ORce) Authorized OracedDtrector/Partner/Manager) State of_ Florida County of Orange The foregoing instrument was acknowledged before me this day of 20 18 by _ Dayna Mitchell Who Is personally own to me Q(OR Name of person melting statement who has produced Identification O type of Identification produced: o, ; TRACY LEIGH MCDONALD i, MY COMMISSION # FF925012 9EXPIRESOctoberOo. 201 Iap7: 39! C 53 FronoalloMlYSowKo Corr Notary signature C CITY OF SANFORD BUILDING & FIRE PREVENTION Jul 2 6 2018 PERMIT APPLICATION Application No: ) 0 ` _' 1 Documented Construction Value: $ —85'J26- V(5L4 I I . 00 Job Address: 3733 Hanworth Loop Historic District: Yes No ER Parcel ID: 17-20-31-5VC-0000-0280 Residential X Commercial Type of Work: New X Addition Alteration Repair Demo Change of Use Move Description of Work: New Single Family Residence Plan Review Contact Person: Tracy McDonald Title: Production Admin Phone: 407-692-9831 Fax: Name NVR INC. dba Ryan Homes Street: 4307 Vineland Rd #H20 City, State Zip: Orlando FL 32811 Email: trmcdonaCa)nvrinc.com Property Owner Information Phone: 407-692-9831 Resident of property? : Contractor Information Name NVR, Inc, dba Ryan Homes Phone: 407-692-9820 Street: 4307 Vineland Rd # H-20 Fax: 407-692-9821 City, State Zip: Orlando FL 32811 State License No.: CBC1257565 Architect/Engineer Information Name: AB Design Street: 1441 N Ronald Reagan Blvd City, St, Zip: Longwood FL Bonding Company: Address: N/A Phone: 407-774-6078 Fax: E-mail: brian@abdesigngroup.com Mortgage Lender: Address: N/A WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: 51' Edition (2014) Florida Building Code Revised June 30, 2015 Permit Application NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal. The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value, credit will be applied to your permit fees when the permit is issued. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. 6/21 /2018 6/21 /2018 Signature of er g t Date Sign atur n ctor/Agent Date Tracy McDonald Tracy cDonald Print Owner/Agent's Name Print Contractor/Agent's Name 6/21 /2018 Signature of NPu ry-State Date R My COMMISSION # GG 063253 EXPIRES: January 17,2021NlO TFOi FLOP Bonded Th- Budget Notary Servltas Owner/Agent is X Personally Known to Me or Produced ID Type of ID 6/21 /2018 Signature of Notary -State of Florida Date o rRY P e MEAGAN LYNNE FOWLER MY COMMISSION # GG 063253 EXPIRES: January 17, 2021 Bonded Thru Budget NotarySewlces Contractor/ Agent is _X Personally Known to Me or Produced ID Type of ID BELOW IS FOR OFFICE USE ONLY Permits Required: Building ® Electrical [9 Mechanical R[ PlumbingR] Gas Roof Construction Type: f_7 Occupancy Use: Flood Zone: X—S tY A r N Total Sq Ft of Bldg: 2' Min. Occupancy Load: 1 # of Stories: New Construction: Electric - # of Amps Z IV Plumbing - # of Fixtures Fire Sprinkler Permit: Yes No Z # of Heads APPROVALS: ZONING: 3 S UTILITIES: COMMENTS: ENGINEERING: NTG '1-fl—g FIRE: Ok to construct single family home with setbacks and impervious area shown on plan. 43,91, ''me. Se" ,.,e - b , 6-R ZI Fire Alarm Permit: Yes No "7 WASTE WATER: BUILDING: 1 w o Revised: June 30, 2015 Permit Application 1 CITY OF SANFORD BUILDING & FIRE PREVENTION D JUN 2 r 019 PERMIT APPLICATION Application No: Documented Construction Value: $ 85,926 Job Address: 3733 Hanworth Loop Historic District: Yes No X Parcel ID: 17-20-31-5VC-0000-0280 Residential Commercial Type of Work: NewEA Addition Alteration Repair Demo Change of Use Move Description of Work: New Single Family Residence Plan Review Contact Person: Tracy McDonald Title: Production Admin Phone: 407-692-9831 Fax: Email: trmcdona@nvrinc.com Property Owner Information Name NVR INC, dba Ryan Homes Phone: 407-692-9831 Street: 4307 Vineland Rd #H20 Resident of property? : City, State Zip: Orlando FL 32811 Name NVR, Inc, dba Ryan Homes Street: 4307 Vineland Rd # H-20 City, State Zip: Orlando FL 32811 Contractor Information Phone: 407-692-9820 Fax: 407-692-9821 State License No.: CBC1257565 Architect/ Engineer Information Name: AB Design Street: 1441 N Ronald Reagan Blvd City, St, Zip: Longwood FL Bonding Company: Address: N/ A Phone: 407-774-6078 Fax: E- mail: brian@abdesigngroup.com Mortgage Lender: Address: N/ A WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: 51h Edition (2014) Florida Building Code Revised: June 30, 2015 Permit Application NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal. The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value, credit will be applied to your permit fees when the permit is issued. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. 6/21 /2018 6/21 /2018 Signature of er g t Date Signatur n ctor/Agent Date Tracy McDonald Tracy cDonald Print Owner/Agent's Name Print Contractor/Agent's Name 6/21 /2018 6/21 /2018 Signature of Notary -State oAE fOWLER Date Signature of Notary -State of Florida Date roltpr vua, MEAD MY COMMISSION # GG 53 2o rR' °j'e. MEAGAN LYNNE FOWLER EXPIRES: January 17, 2021 * MY COMMISSION # GG 063253 ServicesrEOFFpBondedThruBudgetNotary Services EXPIRES: January 17, 2021 OF f%Z; Bonded Thru Budget Notary Services Owner/Agent is _x Personally Known to Me or Contractor/Agent is X Personally Known to Me or Produced ID Type of ID Produced ID Type of ID BELOW IS FOR OFFICE USE ONLY Permits Required: Building Electrical Mechanical Plumbing Gas[] Roof Construction Type: Total Sq Ft of Bldg: Occupancy Use: Min. Occupancy Load: New Construction: Electric - # of Amps Fire Sprinkler Permit: Yes No # of Heads APPROVALS: ZONING: ENGINEERING: COMMENTS: Flood Zone: of Stories: Plumbing - # of Fixtures Fire Alarm Permit: Yes No UTILITIES: " & 6 Zf WASTE WATER: BUILDING: Revised: June 30, 2015 Permit Application CITY OF SJ NFORD PLANNING & DEVELOPMENT SERVICES DEPARTMENT Flood Zone Determination Request Form Name: Tracy McDonald Firm: NVR, Inc. Address: 4307 Vineland Road #H20 City: Orlando State: FL Zip Code: 32811 Phone: 407.692.9831 Fax: 407.692.9821 Email: trmcdona@nvrinc.com Property Address: 3733 Hanworth Loop Property Owner: NVR, Inc. dba Ryan Homes Parcel identification Number: 17-20-31-5VC-0000-0280 Phone Number: 407.692.9820 Email: trmcdona@nvrinc.com The reason for the flood plain determination is: New structure Existing Structure (pre-2007 FIRM adoption) Expansion/Addition Existing Structure (post 2007 FIRM adoption) Pre 2007 FIRM adoption = finished floor elevation 12" above BFE Post 2007 FIRM adoption = finished floor elevation 24" above BFE (Ordinance 4360) OFFIC IAL USE ONLY Flood Zone: X Base Flood Elevation: N/A Datum: N/A FIRM Panel Number: 120294 0090 F Map Date: Sept. 28, 2007 The referenced Flood Insurance Rate Map indicates the following: The parcel is in the: floodplain floodway A portion of the parcel is in the: floodplain floodway The parcel is not in the: M floodplain floodway The structure is in the: floodplain floodway The structure is not in the: floodplain floodway If the subject property is determined to be flood zone 'A', the best available information used to determine the base flood elevation is: BP# 18-2854 Reviewed by: Michael Cash, CFM Date: July 9, 2018 I Application for Paved Driveway, Sidewalk or Walkway0IncludingRight -of -Way Use & 9 9 Y F -1877- Landscaping in Right IIJ -Way www.sanfordfl.gov Department of Planning & Development Services 300 North Park Avenue, Sanford, Florida 32771 Phone:407.688.5140 Fax:407.688.5141 This permit authorizes work to be done on the subject property or in the City of Sanford's right-of-way in accordance with the City's regulations and the attached construction plans approved as part of this permit. The permit is required for driveway or • sidewalk construction over 100 square feet of concrete or other material on the subject parcel and / or any construction of a driveway, walkway or landscape improvements Within the city right-of-way. It does not approve any work within any other jurisdiction's right-of-way. All requested information below as well as a current survey, site plan or plat clearly identifying the Krawaduflbelow. size and location of the existing right—of-way and use shall be provided or application could be delayed. Call beta* you dig. 1. Project Location/Address: 3733 Hanworth Loop, Sanford, FL 32773 2. Proposed Activity: 0 Driveway Walkway Other: 3. Schedule of Work: Start Date Completion Date Emergency Repairs 4. Brief Description of Work: Construction of New Single Family Home This application is s Property Owner: Signature: Address: 4307 in by: H-20 Orlando, FL 32811 Phone: (407) 692-9831 Fax: Print Name: Tracy McDonald Email: trmcdona@nvrinc.com Date: 06/21/2018 Maintenance Responsibilities/Indemnification The Requestor, and his successors and assigns, shall be responsible for perpetual maintenance of the improvement installed under this Agreement. This shall include maintenance of the improvement and unpaved portion of right-of-way adjacent thereto. Requestor may, with written City authorization, remove said installation/improvement fully restoring the right-of-way to its previous condition. In the event that any future construction of roadways, Utilities, stormwater facilities, or any general maintenance activities by the City becomes in conflict with the above permitted activity, the perrnittee shall remove, relocate and/or repair as necessary at no cost to the City of Sanford insofar as such facilities are in the public right-of-way. If the Requestor does not continuously maintain the improvement and area in accordance with previously stated criteria, or completely restore the right-of-way to its previous condition, the City shall, after appropriate notice, restore the area to its previous condition at the Requestor's expense and, if necessary, file a lien on the Requestor's property to recover costs of restoration. To the fullest extent permitted by law, Requestor agrees to defend. indemnify, and hold harmless the City, its councilpersons, agents, servants, or employ- ees (appointed, elected, or hired) from and against any and all liabilities, claims, penalties, demands, suits, judgments, losses, expenses, damages (direct, indirect or consequential), or injury of any nature whatsoever to person or property, and the costs and expenses incident thereto (including costs of defense, settlement, and reasonable attorney's fees up to and including an appeal), resulting in any fashion from or arising directly or indirectly out of or connected with the use of the City's right-of-way. I have Signature: the above statement and by signing this application I agree to its terms. Date: 06/21 /2018 This permit shall be posted on the site during construction. Please call 407.688.5080 24 hours In advance to schedule a pre -pour Inspection. Pre -pour Inspection by: Date: Official Use Only Application No: Fee: Date: Reviewed: Public Works Date: Utilities Date: Approved: 7 n Engineering Date: — u/ Site Inspected by: Date: Special Permit Conditions: November 2015 ROW Use Driveway.pdf 6/21 /2018 SCPA Parcel View: 17-20-31-5VC-0000-0280 Oav10Jotnson, CFA ce eooisJry rt.oret Legal Description LOT 28 KENSINGTON RESERVE PB 81 PGS 86-92 Taxes Property Record Card Parcel: 17-20-31-5VC-0000-0280 Property Address: 3733 HANWORTH LOOP SANFORD, FL 32773 Value Summary 2018 Working Values 2017 Certified Values Valuation Method Cost/Market Cost/Market Number of Buildings 0 0 Depreciated Bldg Value Depreciated EXFT Value Land Value (Market) 67,000 14,000 Land Value Ag Just/Market Value " 67,000 14,000 Portability Adj Save Our Homes Adj 0 0 Amendment 1 Adj 0 0 P&G Adj I $0 0 Assessed Value —{I 67,000 14,000 Tax Amount without SOH: $266.58 2017 Tax Bill Amount $266.58 Tax Estimator Save Our Homes Savings: $0.00 Does NOT INCLUDE Non Ad Valorem Assessments Taxing Authority Assessment Value Exempt Values Taxable Value County General Fund 67,000 0 67,000 Schools 67,000 0 67,000 City Sanford 67,000 0 67,000 SJWM(Saint Johns Water Management) 67,000 0 67,000 County Bonds 67,000 0 67,000 Sales Description Date Book Page Amount Qualified Vac/Imp No Sales Find Comparable Sales Land Method Frontage Depth Units Units Price Land Value LOT 10.00 I 0.00 I 1 I $67,000.00 I $67,000 Building Information Permits Permit # Description I Agency Amount CO Date Permit Date http://parceidetaii.scpafl.org/ParceiDetaillnfo.aspx?PID=1720315VC00000280 1 /2 REQUIRED INSPECTION SEQUENCE RYAN HOMES SFR-DETACHED Permit # BUILDING PERMIT Min Max Inspection Description 10 Form board / Foundation Survey 10 Slab / Mono Slab Pre our 20 Lintel / Tie Beam / Fill / Down Cell 30 Sheathing — Walls 30 Sheathing — Roof 30 50 Final Window 40 Roof Dry In 50 Frame 60 Insulation Rough In 70 Drywall / Sheetrock 40 70 Lath Inspection 50 1000 Final Roof 50 1000 Final Stucco / Siding 80 1000 Insulation Final 1000 Final Single Family Residence Address: ELECTRICAL,EERIVII•T.'' `3;;::, :_ .r,:;',`' ;s {_ <.,.::;;- Min Max Inspection Description 10 Electric Underground 10 Footer / Slab Steel Bond 20 30 Temporary Underground Power (TUG) 30 Electric Rough 1000 Electric Final Min Max Inspection Description 10 Plumbing Underground 20 Plumbing Tubset 10 1000 Plumbing Sewer 1000 Plumbing Final Qr'.L'•¢^_V.Yt1,:i'ynLW-.:JY.....v.. bY MECHACA NIOPWAM.IT,L: rr•.. " nSS".;:n i j 'G''Io jMyr '::,•t"Kr.. T+/.^_ 1-1'• `a! r.,. •; 3:,r,, ': Min Max Inspection Description 10 Mechanical Rough 1000 Mechanical Final REVISED: June 2014 LIMITED POWER OF ATTORNEY Altamonte Springs, Casselberry, Lake Mary, Longwood, Sanford, Seminole County, Winter Springs Date: (o Z 1 I \ I hereby name and appoint: Tracy McDonald an agent of: NVR Inc., dba Ryan Homes Name of Company) to be my lawful attorney -in -fact to act for me to apply for, receipt for, sign for and do all things necessary to this appointment for (check only one option): The specific permit and application for work located at: Expiration Date for This Limited Power of Attorney: License Holder Name: Robert Lattanzi State License Number: CBC12575 Signature of License Holder: STATE OF FLORIDA COUNTY OF Orange May 20,2018 The foregoing instrument was acknowledged before me thiqcQLI_day of TLL4 A 200 18 , by Robert Lattanzi who is ®(person t y7 t me or who has produced identification and who did (did not) take an oath. Notary Seal) r 1 Ar ?u' MEAGAN LYNNE FOWLER MY COMMISSION # GG 063253 ac EXPIRES: January 17, 2021 eOF FL6- Bonded Thru Budget NotarySWm Rev. 08.12) Signature KOA- Ghh FO IN l-JE I - Print or type name Notary Public - State of _ Commission No. My Commission Expires: as SQ.FT. CALC.'S LIVMG 2034 50. Ff. GARAGE 429 50. FT. ENTRY 30 SQ. Ff. LANAI W 50. FT. TOTAL 2581 50. FT. EXTERIOR MASONRY NOTE, PRIOR TO DRYWALL WALL BFY. HEIGHTS MSTALLATION ON ALL FRAMING MEMBERS 7'-0' FROM THE FINISH FLOOR WILL BE SPRAYED AND TREATED W/ 'BORATE' A TERMITE V-4' ENPC& TREATMENT SPRAT LOAD BF r- WALL COLIIINM T AND C LAMNO MRD LAADB SABO YRD EX-09/E FOR 3 BEOOID SIB cmki smiw mle YMOoFOWAM I IQ 16 - 1.1 _01 5 74.9/ -30.5 7 71 30M DR 4 71D0/ -3020 3 19 cpr eb 5 7820/ -3695 3A is 0P,pp 5 7820/ -3695 35 1 TEMP4 78AV -30.9 4 n EGRESS 4 784V -30.5 4A n 75-514 4 78AV -30.9 45 n 75-844 5 78AV -3131 5 n 75-SW 5 78AV -3131 6 n 75-614 4 78AV -305 1 48 6090-8GD. 5 303/ -400 8 n 75-SW 4 70AV -30.9 9 n 75-SH 4 78AV-309 l0 n 7OW 4 78AV -30.9 II n GRESS 5 78AV -3131 D n 7E E 4 29" -30.9 I7A 4 TRANSOM 4 7343/ -3LW 0 n 7EC 1 5 78AV _3131 WIND DESIGN CRITERIA A BAN C UDlD 6PEID I•Di[ [! 6EG070 fiUST) iLT. 60 / VA60•Db MPA B. INTE)WOL PR286L/E CDE FI[ENT.. JO 4 R15K CATEGORY.TYT-E II D. E) CATEGORY C NOTE, VALVE5 FOR COMPC ENTS . C3ADDIFG PIREaOLIRE ARE BASED CN TIE "A DEWW4 WIND 6P®. FBCR 6TN ED' (2011) ALLOW5 THERE PRE-58URE8 TO BE MILTIPL® BY 0,6 TO Ili TFE ALLOULABLE OR NOMDCAL TESTED VALUES USED BY PAOOUCT MANFACTUREW. AA CABINET SECTION c Y 9 Q ARCH DETAIL 2 ARCH DETAIL 3) ARCH DETAIL ARCH DETAIL 7'- 8' 0= 00R-, KROEN pm- mim M= vE TO EXTERIOR - X- 7 9•- 8 4'-4' Y-10' G 9 10 II 75- 844 75-SH 75-8H 75-5H LANAI l I EGRESS EGRESS 114•- 7' I I'° 5 6 m 0 m GREAT RM, 14'- 0'xIS'-0' OWNER'S SUITE 75-5H 75_SH M 0 11 V V-4- CLG. 1 Of= I 9 4' CLG r V- 4' CLG. 1 mm m w I5'- 5' I7'-4- X-10' CABI I'ETCROWMLm 1 11 Ir- OMCEIEN I I I III I I 9 _!' Cm• 1 I Ov. 150A _ J mmin 5 ING pp4 . III IIl RO s-0s-0 3'_0' a III V-4' CLG. U e V-0 s a ~ mRUT 10 C6'- 0' 10' 4'-4' 5-_8. I._4. 4) 4'-10' l'-10' Y• 44' HKaFI I m g I C I7 7 UL1LL B'1 8-O'x4'_S' 9'-4'CLG. ALL' ate. I4 Q1 a CABNET CRMN 6] O K1 Itp(A Z e,_b.LAV. I 4' EIDRM.94 _ m 10'-m5c10'-0' 1 D atiee I s• Y HDRM. 13 10'- O'x17'_ 8• 9'-4' CLG. 1 c,- V-4' CLG. 10'-10' 7'- 4 I 10'u 1'-7' 3•-8' 0 I 5- 0 • .c 7 - II BF. ; Y r--lr-- 1 OPT OPT IInw I-D.11WC. 9 W. 1 I + pFr PNFl O n GLQ' -1-1 J LA HATHl1 ° II Y w-I O b•-Io•m'-r 7 3 O Y-4• CLG. I 1 0 UTLLIn YJ' Clfi f y Si73' l 5w Q I I 9 ILAGCEaBJ ATTIC I YITdEJBFILR1d FQT H 2- CAR GARAGE O 5-0 BF. 10' b' I'_4• HDRM•, 62 7 T. i7'-4' xl0'- 0' 7'-b m Y 76- 6I4 76-SH ARGHT OP v- i+b'-s' 3A EGRESS EGRESS O a-WaA TONE VO4EER e- b' X- 10' S'- 1. 4'-0' 40'-0. FLOOR PLAN SCALE}' . I'-V ELEVATION V' a A I C N I T E C T 8 GDesfn rou Ina iM1NNONALD RGGAN •LVD LONG WOOD, FL 37170 w FAL407-77- 073 MaILNVDND com Mf0003] 37 r 8 CD E O L C 9UHDIV. de LOT•. KENSINGTON RESERVE CAT # 28) MODElz SEAGATE VERSION# 04) P"' oJZCT/I: 02997.000 02BR1 PAGIC: FLOOR PLAN DATM 5/ 24/ 18 9CAum 1/4'= 1'-0' Bill= 2 07r 6 FORM R405-2017 RECORD COPY FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Lot28KensingtonReserveSeagateDGRE Builder Name: RYAN HOMES Street: 3733 HANWORTH LOOP Permit Office: ,b64 O D_ 2 8 5 4 BU/1,0 City, State, Zip: SANFORD , FL, 32773 Permit Number. S G" Owner: Jurisdiction: 691500 q i/, 0 Design Location: FL, Orlando County:: Seminole (Florida Climate Zo) R A E 1. New construction or existing New (From Plans) 9. Wall Types (1936.7 sqft.) Insulate rea 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=4.1 1614.70 ft2 b. Frame - Wood, Adjacent R=13.0 322.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 4 d. N/A R= ft2 10. Ceiling Types (2048.0 sqft.) Insulation Area 5. Is this a worst case? No a. Under Attic (Vented) R=38.0 2048.00 ft2 6. Conditioned floor area above grade (ft2) 2034 b. N/A R= ft2 c. R= ft2 Conditioned floor area below grade (ft2) 0 11. Ducts R ft2 7. Windows(268.5 sqft.) Description Area a. Sup: Attic, Ret: Main, AH: Main 6 406.8 a. U-Factor. Dbl, U=0.35 216.60 ft2 SHGC: SHGC=0.29 b. U-Factor. Dbl, U=0.62 48.00 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.29 a. Central Unit 34.8 SEER:15.00 c. U-Factor: Dbl, U=0.34 3.85 ft2 SHGC: SHGC=0.31 13. Heating systems kBtu/hr Efficiency d. U-Factor. N/A ft2 a. Electric Heal Pump 32.6 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 3.932 ft. Area Weighted Average SHGC: 0.290 14. Hot water systems a. Electric Cap: 50 gallons 8. Floor Types (2034.0 sqft.) Insulation Area EF: 0.950 a. Slab -On -Grade Edge Insulation R=0.0 2034.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 15. Credits Pstat Glass/ Floor Area: 0.132 Total Proposed Modified Loads: 58.28 PASS Total Baseline Loads: 61.87 I hereby certify that the plans and spe ifications covered by Review of the plans and gliE Sr'4?' 0this calculation are in compliance wi the Florida Energy specifications covered by this pti. Code. calculation indicates compliance FOB, with the Florida Energy Code. O N PREPARED BY: ' " T- Before construction is completed DATE: 5-99-111 Srnff Pratt this building will be inspected for compliance with Section 553.908 I hereby certify that this buildin9las designed, is in compliance Florida Statutes. COD withtheFloridaEnergyCode. WE T¢J OWNER/ AGENT: BUILDING OFFICIA DATE: 5/29/2018 DATE: Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 5/ 29/2018 2:20 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 5 C.none onnt_'n17 PROJECT Title: Building Type: Owner Name: of Units: Builder Name: Permit Office: Jurisdiction: Family Type: New/Existing: Comment: Lot28KensingtonReserveSea Bedrooms: 4 User Conditioned Area: 2034 Total Stories: 1 1 Worst Case: No RYAN HOMES Rotate Angle: 0 SANFORD Cross Ventilation: No 691500 Whole House Fan: No Single-family New (From Plans) Address Type: Street Address Lot # 28 Block/Subdivision: KENSINGTON PlatBook: Street: 3733 HANWORTH LO County: Seminole City, State, Zip: SANFORD , FL. 32773 CLIMATE Design Location Design Temp TMY Site 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, Orlando FL_ORLANDO_INTL_AR 41 91 70 75 526 44 Medium BLOCKS Number Name Area Volume 1 Blockl 2034 18916.2 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 2034 18916.2 Yes 5 4 1 Yes Yes Yes FLOORS Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 173.5 ft 0 2034 ft' 0.34 0 0.66 ROOF V # Type Roof Gable Roof Materials Area Area Color Solar Absor. SA Emitt Emitt Deck Pitch Tested Tested Insul. (deg) 1 Gable or Shed Composition shingles 2275 ft' 510 ft' Medium 0.85 N 0.85 No 0 26.6 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 2034 ft' N N CEILING Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) Main 38 Blown 2048 ft' 0.11 Wood 5/29/2018 2:20 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 5 moon onnr,_0n17 WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Space 0 1 E Exterior Concrete Block - Int Insul Main 4.1 4 7 9 4 42.8 ft2 0 0 0.6 0 2 E Exterior Concrete Block - Int Insul Main 4.1 14 5 9 4 134.6 ft2 0 0 0.6 0 3 N Exterior Concrete Block - Int Insul Main 4.1 28 2 9 4 262.9 ft2 0 0 0.6 0 4 N Exterior Concrete Block - Int Insul Main 4.1 15 4 9 4 143.1 ft2 0 0 0.6 0 5 N Exterior Concrete Block - Int Insul Main 4.1 6 10 9 4 63.8 ft' 0 0 0.6 0 6 W Exterior Concrete Block - Int Insul Main 4.1 14 11 9 4 139.2 ft' 0 0 0.6 0 7 W Exterior Concrete Block - Int Insul Main 4.1 10 11 9 4 101.9 ft2 0 0 0.6 0 8 W Exterior Concrete Block - Int Insul Main 4.1 13 11 9 4 129.9 ft2 0 0 0.6 0 9 S Exterior Concrete Block - Int Insul Main 4.1 20 3 9 4 189.0 ft2 0 0 0.6 0 10 S Exterior Concrete Block - Int Insul Main 4.1 9 3 9 4 86.3 ft' 0 0 0.6 0 11 S Exterior Concrete Block - Int Insul Main 4.1 17 3 9 4 161.0 ft2 0 0 0.6 0 12 S Exterior Concrete Block - Int Insul Main 4.1 17 2 9 4 160.2 ft' 0 0 0.6 0 13 Garage Frame - Wood Main 13 34 6 9 4 322.0 ft' 0 0.23 0.01 0 DOORS Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 E Insulated Main None 25 3 8 24 ft' 2 Wood Main None 25 2 8 16 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. Wall Overhang Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 E 2 Vinyl Low-E Double Yes 0.35 0.29 N 38.5 ft' 1 ft 0 in 3 ft 9 in Drapes/blinds Exterior 5 2 N 3 Vinyl Low-E Double Yes 0.35 0.29 N 32.4 ft2 1 ft 0 in 1 ft 2 in Drapes/blinds Exterior 5 3 N 4 Vinyl Low-E Double Yes 0.34 0.31 N 3.9 ft' 1 ft 0 in 1 ft 2 in Drapes/blinds None 4 W 6 Vinyl Low-E Double Yes 0.35 0.29 N 32.4 ft' 1 ft 0 in 1 ft 2 in Drapes/blinds Exterior 5 5 W 7 Vinyl Low-E Double Yes 0.35 0.29 N 32.4 ft' 9 ft 0 in 0 ft 4 in Drapes/blinds Exterior 5 6 W 8 Vinyl Low-E Double Yes 0.35 0.29 N 32.4 ft' 1 ft 0 in 1 ft 2 in Drapes/blinds Exterior 5 7 S 9 Vinyl Low-E Double Yes 0.35 0.29 N 48.6 ft' 1 ft 0 in 1 ft 2 in Drapes/blinds Exterior 5 8 S 10 Metal Low-E Double Yes 0.62 0.29 N 48.0 ft' 12 ft 0 in 0 ft 4 in Drapes/blinds Exterior 5 GARAGE Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 429 ft' 429 ft2 78 ft 9.3 ft 1 5/29/2018 2:20 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 5 rnDne Dnnr On-17 INFILTRATION Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) 000414 2206.9 121.16 227.85 .302 7 HEATING SYSTEM System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split HSPF:8.5 32.6 kBtu/hr 1 sys#1 COOLING SYSTEM System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 15 34.8 kBtu/hr cfm 0.75 1 sys#1 HOT WATER SYSTEM System Type SubTpe Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 50 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector Storage System Model # Collector Model # Area Volume FEF None None ft' DUCTS Supply -- Location R-Value Area Return — Air CFM 25 CFM25 Location Area Leakage Type Handler TOT OUT QN RLF HVAC # Heat Cool 1 Attic 6 406.8 ft Main 101.7 ft Default Leakage Main (Default) (Default) 1 1 TEMPERATURES Programablje ThermostatJan: jYFebj jHeating [X] Jan [X] Feb [X] Mar Venting [ ] Jan [ ] Feb [X] Mar j Ceiling Fans: CoolinjX] njX] j Oct Nov L 1 Pr I i Ma JunMay 11Jun [ j Jul Aug [ ]Sep L 1 NNov lxlJun [ ] Jul Aug [ ] Sep lxJOct ov Dec Dec Dec 5/ 29/2018 2:20 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 5 nDne DAnr_on!7 Thermostat Schedule: Schedule Type HERS 2006 Reference 1 2 3 4 5 Hours 6 7 8 9 10 11 12 Cooling (WD) AM PM 78 80 78 80 78 78 78 78 78 78 78 78 78 78 78 78 80 78 80 78 80 78 80 78 Cooling (WEH) AM PM 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM PM 66 68 66 68 66 68 66 68 66 68 68 68 68 68 68 68 68 68 68 68 68 66 68 66 Heating (WEH) AM PM 66 68 66 68 66 68 66 68 66 68 68 68 68 68 68 68 68 68 68 68 68 66 68 66 5/29/2018 2:20 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 5 of 5 FORM R405-2017 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 94 The lower the EnergyPerformance Index, the more efficient the home. 3733 HANWORTH LOOP, SANFORD, FL, 32773 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (ft') 7. Windows" Description a. U-Factor. Dbl, U=0.35 SHGC: SHGC=0.29 b. U-Factor. Dbl, U=0.62 SHGC: SHGC=0.29 c. U-Factor: Dbl, U=0.34 SHGC: SHGC=0.31 d. U-Factor. N/A SHGC: Area Weighted Average Overhang Depth: Area Weighted Average SHGC: 8. Floor Types a. Slab -On -Grade Edge Insulation b. N/A c. N/A New (From Plans) 9. Wall Types Single-family a. Concrete Block - Int Insul, Exterior b. Frame - Wood, Adjacent 1 c. N/A 4 d. N/A 10. Ceiling Types No a. Under Attic (Vented) 2034 b. N/A c. N/A Area 11. Ducts 216.60 ft2 a. Sup: Attic, Ret: Main, AH: Main 48.00 ft2 12. Cooling systems 3.85 ft' a. Central Unit ft' 3.932 ft. 0.290 Insulation Area R=0.0 2034.00 ft' R= ft' R= ft' 13. Heating systems a. Electric Heat Pump 14. Hot water systems a. Electric b. Conservation features None 15. Credits I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code comoliapt fr lures. Builder Signature: Address of New Home: 3733 Date: 5/29/2018 City/FL Zip: 32773 Insulation Area R=4.1 1614.70 ft2 R=13.0 322.00 ft' R= ft2 R= ft' Insulation Area R=38.0 2048.00 ft' R= ft2 R= ft' R ft2 6 406.8 kBtu/hr Efficiency 34.8 SEER:15.00 kBtu/hr Efficiency 32.6 HSPF:8.50 Cap: 50 gallons EF: 0.95 Pstat TKe sr' F SOD WE Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 5/29/2018 2:20 PM EnergyGauge® USA - FlaRes2017 - Section R405.4.1 Compliant Software Page 1 of 1 Florida Building Code, Energy Conservation, 6th Edition (2017) Mandatory Requirements for Residential Performance, Prescriptive and ERI Methods ADDRESS: 3733 HANWORTH LOOP Permit Number: SANFORD, FL, 32773 MANDATORY REQUIREMENTS See individual code sections for full details. SECTION R401 GENERAL R401.3 Energy Performance Level (EPL) display card (Mandatory)The building official shall require that an energy performance level (EPL) display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy. Florida law Section 553.9085, Florida Statutes) requires the EPL display card to be included as an addendum to each sales contract for both presold and nonpresold residential buildings. The EPL display card contains information indicating the energy performance level and efficiencies of components installed in a dwelling unit. The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans and specifications submitted to demonstrate code compliance for the building. A copy of the EPL display card can be found in Appendix RD. R402.4 Air leakage (Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of Sections R402.4.1 through R402.4.5. Exception: Dwelling units of R-2 Occupancies and multiple attached single family dwellings shall be permitted to comply with Section C402.5. R402.4.1 Building thermal envelope. The building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2. The sealing methods between dissimilar materials shall allow for differential expansion and contraction. R402.4.1.1 Installation The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance with the manufacturer's instructions and the criteria listed in Table R402.4.1.1, as applicable to the method of construction. Where required by the code official, an approved third party shall inspect all components and verify compliance. R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate not exceeding seven air changes per hour in Climate Zones 1 and 2, and three air changes per hour in Climate Zones 3 through 8. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g. (50 pascals). Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(0, (g) or (i) or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. Exception: Testing is not required for additions, alterations, renovations, or repairs, of the building thermal envelope of existing buildings in which the new construction is less than 85 percent of the building thermal envelope. During testing: 1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or other infiltration control measures. 2. Dampers including exhaust, intake, makeup air, backdraft and flue dampers shall be closed, but not sealed beyond intended infiltration control measures. 3. Interior doors, if installed at the time of the test, shall be open. 4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5. Heating and cooling systems, if installed at the time of the test, shall be turned off. 6. Supply and return registers, if installed at the time of the test, shall be fully open. R402.4.2 Fireplaces. New wood-buming fireplaces shall have tight -fitting flue dampers or doors, and outdoor combustion air. Where using tight -fitting doors on factory -built fireplaces listed and labeled in accordance with UL 127, the doors shall be tested and listed for the fireplace. Where using tight -fitting doors on masonry fireplaces, the doors shall be listed and labeled in accordance with UL 907. R402.4.3 Fenestration air IeakageWindows, skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm per square foot (1.5 Us/m2), and swinging doors no more than 0.5 cfm per square foot (2.6 Us/m2), when tested according to NFRC 400 or AAMA/ WDMA/CSA 101/I.S.2/A440 by an accredited, independent laboratory and listed and labeled by the manufacturer. Exception: Site -built windows, skylights and doors. 5/29/2018 2:20 PM EnergyGauge® USA - FlaRes2017 - FBC 6th Edition (2017) Complia Page 1 of 5 MANDATORY REQUIREMENTS - (Continued) R402.4.4 Rooms containing fuel -burning appliances. In Climate Zones 3 through 8, where open combustion air ducts provide combustion air to open combustion fuel burning appliances, the appliances and combustion air opening shall be located outside the building thermal envelope or enclosed in a room, isolated from inside the thermal envelope. Such rooms shall be sealed and insulated in accordance with the envelope requirements of Table R402.1.2, where the walls, floors and ceilings shall meet not less than the basement wall R-value requirement. The door into the room shall be fully gasketed and any water lines and ducts in the room insulated in accordance with Section R403. The combustion air duct shall be insulated where it passes through conditioned space to a minimum of R-8. Exceptions: 1. Direct vent appliances with both intake and exhaust pipes installed continuous to the outside. 2. Fireplaces and stoves complying with Section R402.4.2 and Section R1006 of the Florida Building Code, Residential. R402.4.5 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage between conditioned and unconditioned spaces. All recessed luminaires shall be IC -rated and labeled as having an air leakage rate not more than 2.0 cfm (0.944 Us) when tested in accordance with ASTM E283 at a 1.57 psf (75 Pa) pressure differential. All recessed luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering. SECTION R403 SYSTEMS R403.1 Controls. R403.1.1 Thermostat provision (Mandatory). At least one thermostat shall be provided for each separate heating and cooling system. R403.1.3 Heat pump supplementary heat (Mandatory). Heat pumps having supplementary electric -resistance heat shall have controls that, except during defrost, prevent supplemental heat operation when the heat pump compressor can meet the healing load. R403.3..2 Sealing (Mandatory) All ducts, air handlers, filter boxes and building cavities that form the primary air containment passageways for air distribution systems shall be considered ducts or plenum chambers, shall be constructed and sealed in accordance with Section C403.2.9.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria below. Duct tightness shall be verified by testing in accordance with ANSI/RESNET/ICC 380 by either individuals as defined in Section 553.993(5) or 7), Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(0, (g) or (i), Florida Statutes, to be "substantially leak free" in accordance with Section R403.3.3. R403.3.2.1 Sealed air handler. Air handlers shall have a manufacturer's designation for an air leakage of no more than 2 percent of the design airflow rate when tested in accordance with ASHRAE 193. R403.3.3 Duct testing (Mandatory). Ducts shall be pressure tested to determine air leakage by one of the following methods: Rough -in test: Total leakage shall be measured with a pressure differential of 0.1 inch w.g. (25 Pa) across the system, including the manufacturer's air handler enclosure if installed at the time of the lest. All registers shall be taped or otherwise sealed during the test. 2. Postconstruction test: Total leakage shall be measured with a pressure differential of 0.1 inch w.g. (25 Pa) across the entire system, including the manufacturer's air handler enclosure. Registers shall be taped or otherwise sealed during the test. Exceptions: 1. A duct air leakage test shall not be required where the ducts and air handlers are located entirely within the building thermal envelope. 2. Duct testing is not mandatory for buildings complying by Section 405 of this code. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. R403.3.5 Building cavities (Mandatory). Building framing cavities shall not be used as ducts or plenums. R403.4 Mechanical system piping insulation (Mandatory). Mechanical system piping capable of carrying fluids above 105'F (41°C) or below 55'F (13'C) shall be insulated to a minimum of R-3. R403.4.1 Protection of piping insulation. Piping insulation exposed to weather shall be protected from damage, including that caused by sunlight, moisture, equipment maintenance and wind, and shall provide shielding from solar radiation that can cause degradation of the material. Adhesive tape shall not be permitted. R403.5.1 Heated water circulation and temperature maintenance systems (Mandatory) Heated water circulation systems shall be in accordance with Section R403.5.1.1. Heat trace temperature maintenance systems shall be in accordance with Section R403.5.1.2. Automatic controls, temperature sensors and pumps shall be accessible. Manual controls shall be readily accessible. R403.5.1.1 Circulation systems. Heated water circulation systems shall be provided with a circulation pump. The system return pipe shall be a dedicated return pipe or a cold water supply pipe. Gravity and thermosiphon circulation systems shall be prohibited. Controls for circulating hot water system pumps shall start the pump based on the identification of a demand for hot water within the occupancy. The controls shall automatically turn off the pump when the water in the circulation loop is at the desired temperature and when there is no demand for hot water. R403.5.1.2 Heat trace systems. Electric heat trace systems shall comply with IEEE 515.1 or UL 515. Controls for such systems shall automatically adjust the energy input to the heat tracing to maintain the desired water temperature in the piping in accordance with the times when heated water is used in the occupancy. 5/29/2018 2:20 PM EnergyGauge® USA - FlaRes2017 - FBC 6th Edition (2017) Complian Page 2 of 5 MANDATORY REQUIREMENTS - (Continued) R403.5.5 Heat traps (Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have heal traps installed on both the inlets and outlets. External heal traps shall consist of either a commercially available heat trap or a downward and upward bend of at least 3 % inches (89 mm) in the hot water distribution line and cold water line located as close as possible to the storage tank. R403.5.6 Water heater efficiencies (Mandatory). R403.5.6.1.1 Automatic controls. Service water -heating systems shall be equipped with automatic temperature controls capable of adjustment from the lowest to the highest acceptable temperature settings for the intended use. The minimum temperature setting range shall be from 100'F to 140'F (38'C to 60'C). R403.5.6.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to electric service systems to be turned off. A separate valve shall be provided to permit the energy supplied to the main burner(s) of combustion types of service water -heating systems to be turned off. R403.5.6.2 Water -heating equipment. Water -heating equipment installed in residential units shall meet the minimum efficiencies of Table C404.2 in Chapter 4 of the Florida Building Code, Energy Conservation, Commercial Provisions, for the type of equipment installed. Equipment used to provide heating functions as part of a combination system shall satisfy all slated requirements for the appropriate water -heating category. Solar water heaters shall meet the criteria of Section R403.5.6.2.1. R403.5.6.2.1 Solar water -heating systems. Solar systems for domestic hot water production are rated by the annual solar energy factor of the system. The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of Certified Solar Systems. Solar collectors shall be tested in accordance with ISO Standard 9806, Test Methods for Solar Collectors, and SRCC Standard TM-1, Solar Domestic Hot Water System and Component Test Protocol. Collectors in installed solar water -heating systems should meet the following criteria: 1. Be installed with atilt angle between 10 degrees and 40 degrees of the horizontal; and 2. Be installed at an orientation within 45 degrees of true south. R403.6 Mechanical ventilation (Mandatory). The building shall be provided with ventilation that meets the requirements of the Florida Building Code, Residential, or Florida Building Code, Mechanical, as applicable, or with other approved means of ventilation including: Natural, Infiltration or Mechanical means. Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system is not operating. R403.6.1 Whole -house mechanical ventilation system fan efficacy.When installed to function as a whole -house mechanical ventilation system, fans shall meet the efficacy requirements of Table R403.6.1. Exception: Where whole -house mechanical ventilation fans are integral to tested and listed HVAC equipment, they shall be powered by an electronically commutated motor. R403.6.2 Ventilation air. When installed to function as a whole -house mechanical ventilation system, fans shall meet the efficacy requirements of Table R403.6.1. 1. The design air change per hour minimums for residential buildings in ASHRAE 62.2, Ventilation for Acceptable Indoor Air Quality, shall be the maximum rates allowed for residential applications. 2. No ventilation or air-conditioning system make-up air shall be provided to conditioned space from attics, crawlspaces, attached enclosed garages or outdoor spaces adjacent to swimming pools or spas. 3. If ventilation air is drawn from enclosed space(s), then the walls of the space(s) from which air is drawn shall be insulated to a minimum of R-11 and the ceiling shall be insulated to a minimum of R-19, space permitting, or R-10 otherwise. R403.7 Heating and cooling equipment (Mandatory). R403.7.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies, based on building loads for the directional orientation of the building. The manufacturer and model number of the outdoor and indoor units (if split system) shall be submitted along with the sensible and total cooling capacities at the design conditions described in Section R302.1. This Code does not allow designer safety factors, provisions for future expansion or other factors that affect equipment sizing. System sizing calculations shall not include loads created by local intermittent mechanical ventilation such as standard kitchen and bathroom exhaust systems. New or replacement heating and cooling equipment shall have an efficiency rating equal to or greater than the minimum required by federal law for the geographic location where the equipment is installed. TABLE R403.6.1 WHOLE -HOUSE MECHANICAL VENTILATION SYSTEM FAN EFFICACY FAN LOCATION AIRFLOW RATE MINIMUM CFM) MINIMUM EFFICACY a CFM/WATT) AIRFLOW RATE MAXIMU CFM) Range hoods Any 2.8 cfm/watt Any In -line fan Any 2.8 cfm/watt Any Bathroom, utility room 10 1.4 cfm/watt 90 Bathroom, utility room 90 2.8 cfm/watt Any For SI: 1 cfm = 28.3 Umin. a. When tested in accordance with HVI Standard 916 5/29/2018 2:20 PM EnergyGauge® USA - FlaRes2017 - FBC 6th Edition (2017) Complia Page 3 of 5 MANDATORY REQUIREMENTS - (Continued) R403.7.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less than the calculated total load but not more than 1.15 times greater than the total load calculated according to the procedure selected in Section 403.7, or the closest available size provided by the manufacturers product lines. The corresponding latent capacity of the equipment shall not be less than the calculated latent load. The published value for AHRI total capacity is a nominal, rating -test value and shall not be used for equipment sizing. Manufacturers expanded performance data shall be used to select cooling -only equipment. This selection shall be based on the outdoor design dry-bulb temperature for the load calculation (or entering water temperature for water -source equipment), the blower CFM provided by the expanded performance data, the design value for entering wet -bulb temperature and the design value for entering dry-bulb temperature. Design values for entering wet -bulb and dry-bulb temperatures shall be for the indoor dry bulb and relative humidity used for the load calculation and shall be adjusted for return side gains if the return duct(s) is installed in an unconditioned space. Exceptions: 1. Attached single- and multiple -family residential equipment sizing may be selected so that its cooling capacity is less than the calculated total sensible load but not less than 80 percent of that load. 2. When signed and sealed by a Florida -registered engineer, in attached single- and multiple -family units, the capacity of equipment may be sized in accordance with good design practice. R403.7.1.2 Heating equipment capacity. R403.7.1.2.1 Heat pumps. Heal pump sizing shall be based on the cooling requirements as calculated according to Section R403.7.1.1, and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load even if the design heating load is 1.15 times greater than the design cooling load. R403.7.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design requirements calculated according to the procedure selected in Section R403.7.1. R403.7.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners shall not be less than the design load calculated in accordance with Section R403.7.1. R403.7.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an intermittent basis, such as anticipated additional loads caused by major entertainment events, shall have equipment sized or controlled to prevent continuous space cooling or heating within that space by one or more of the following options: 1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas. 2. A variable capacity system sized for optimum performance during base load periods is utilized. R403.8 Systems serving multiple dwelling units (Mandatory). Systems serving multiple dwelling units shall comply with Sections C403 and C404 of the IECC—Commercial Provisions in lieu of Section R403. R403.9 Snow melt and ice system controls (Mandatory) Snow- and ice -melting systems, supplied through energy service to the building, shall include automatic controls capable of shutting off the system when the pavement temperature is above 50"F (10°C), and no precipitation is falling and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40'F (4.8"C). R403.10 Pools and permanent spa energy consumption (Mandatory). The energy consumption of pools and permanent spas shall be in accordance with Sections R403.10.1 through R403.10.5. R403.10.1 Heaters. The electric power to heaters shall be controlled by a readily accessible on -off switch that is an integral part of the heater mounted on the exterior of the heater, or external to and within 3 feet (914 mm) of the heater. Operation of such switch shall not change the setting of the heater thermostat. Such switches shall be in addition to a circuit breaker for the power to the heater. Gas -fired heaters shall not be equipped with continuously burning ignition pilots. R403.10.2 Time switches. Time switches or other control methods that can automatically turn off and on according to a preset schedule shall be installed for heaters and pump motors. Heaters and pump motors that have built-in time switches shall be in compliance with this section. Exceptions: 1. Where public health standards require 24-hour pump operation. 2. Pumps that operate solar- and waste -heat -recovery pool heating systems. 3. Where pumps are powered exclusively from on -site renewable generation. R403A0.3 Covers. Outdoor heated swimming pools and outdoor permanent spas shall be equipped with a vapor -retardant cover on or at the water surface or a liquid cover or other means proven to reduce heat loss. Exception: Where more than 70 percent of the energy for heating, computed over an operation season, is from site -recovered energy, such as from a heat pump or solar energy source, covers or other vapor -retardant means shall not be required. R403.10.4 Gas- and oil -fired pool and spa heaters. All gas- and oil -fired pool and spa heaters shall have a minimum thermal efficiency of 82 percent for heaters manufactured on or after April 16, 2013, when tested in accordance with ANSI Z 21.56. Pool heaters fired by natural or LP gas shall not have continuously burning pilot lights. 5/29/2018 2:20 PM EnergyGauge® USA - FlaRes2017 - FBC 6th Edition (2017) Complia Page 4 of 5 R403.10.5 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance with AHRI 1160, Table 2, Standard Rating Conditions -Low Air Temperature. A test report from an independent laboratory is required to verify procedure compliance. Geothermal swimming pool heat pumps are not required to meet this standard. R403.11 Portable spas (Mandatoryte energy consumption of electric -powered portable spas shall be controlled by the requirements of APSP-14. SECTION R404 ELECTRICAL POWER AND LIGHTING SYSTEMS R404.1 Lighting equipment (Mandatory). Not less than 75 percent of the lamps in permanently installed lighting fixtures shall be high -efficacy lamps or not less than 75 percent of the permanently installed lighting fixtures shall contain only high -efficacy lamps. Exception: Low -voltage lighting. R404.1.1 Lighting equipment (Mandatory)Fuel gas lighting systems shall not have continuously burning pilot lights. 5/29/2018 2:20 PM EnergyGauge® USA - FlaRes2017 - FBC 6th Edition (2017) Complia Page 5 of 5 FORM R405-2017 RESIDENTIAL ENERGY CONSERVATION CODE DOCUMENTATION CHECKLIST Florida Department of Business and Professional Regulation Simulated Performance Alternative (Performance) Method Applications for compliance with the 2017 Florida Building Code, Energy Conservation via the residential Simulated Performance Method shall include: This checklist A Form R405 report that documents that the Proposed Design complies with Section R405.3 of the Florida Energy Code. This form shall include a summary page indicating home address, a -ratio and the pass or fail status along with summary areas and types of components, whether the home was simulated as a worst -case orientation, name and version of the compliance software tool, name of individual completing the compliance report (one page) and an input summary checklist that can be used for field verification (usually four pages/may be greater). Energy Performance Level (EPL) Display Card (one page) HVAC system sizing and selection based on ACCA Manual S or per exceptions provided in Section R403.7 Mandatory Requirements (five pages) Required prior to CO for the Performance Method: Air Barrier and Insulation Inspection Component Criteria checklist (Table R402.4.1.1 - one page) A completed Envelope Leakage Test Report (usually one page) If Form R405 duct leakage type indicates anything other than "default leakage", then a completed Form R405 Duct Leakage Test Report (usually one page) EnergyGauge® - USRCSB v6.0 5/29/2018 2:19:22 PM Page 1 of 1 Manual S Compliance Report Job: LotMensingtonResetv... wrightsoft• p P Date: 09-12-11 Entire House By: Vw DEL -AIR HEATING & AIR CONDITIONING 531 CODISCO WAY, SANFORD, FL 32771 Phone: 407-333-2665 Fax: 407-333-3853 Web: WWW.DEL-AIR.COM ect 1n10rmduc For: RYAN HOMES 3733 HANWORTH LOOP, SAN FORD, FL 32773 Cooling Equipment Design Conditions Outdoor design DB: 92.5°F Sensible gain: 28442 Btuh Entering coil DB: 77.4°F Outdoor design WB: 76.2°F Latent gain: 5709 Btuh Entering coil WB: 64.1°F Indoor design DB: 75.0°F Total gain: 34151 Btuh Indoor RH: 50% Estimated airflow: 1160 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASH Manufacturer: Goodman Mfg. Actual airflow: 1160 cfm Sensible capacity: 29100 Btuh Latent capacity: 5741 Btuh Total capacity: 34842 Btuh Model: GSZ140361K+ASPT47D14A 1020/6 of load 101% of load 1020/6 of load SHR: 84% Heating Equipment Design Conditions Outdoor design DB: 42.3°F Heat loss: 27073 Btuh Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASH Manufacturer: Goodman Mfg. Model: GSZ140361K+ASPT47D14A Actual airflow: 1160 cfm Output capacity: 32600 Btuh 120% of load Supplemental heat required: 0 Btuh Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 1160 cfm Output capacity: 7.9 kW 99% of load Temp. rise: 50 OF Meets all requirements of ACCA Manual S. Entering coil DB: 68.1OF Capacity balance: 37 OF Economic balance: -99 OF wrightsoft' 2018-May-29 14-15-04 C Right -Suite® Universal 2018 18.0.13 RSU23828 Page 1 I'M...agateDGRE\Lot28KensingtonReserveSeagateDGRE.rup Calc = MJ8 Front Door laces: E ComponentCom Constructions Job: Lot28KensingtonReserv... Wrightsoft' P Date: 09-12-11 Entire House By: VMT DEL -AIR HEATING & AIR CONDITIONING 531 CODISCO WAY, SANFORD, FL 32771 Phone: 407.333-2665 Fax: 407.333-3853 Web: WWW.DEL-AIR.COM mmmect inTormapon For: RYAN HOMES 3733 HANWORTH LOOP, SANFORD, FL 32773 Design Conditions Location: Indoor: Heating Cooling Orlando/Jetport, FL, US Indoor temperature (OF) 70 75 Elevation: 105 ft Design TD (OF) 28 18 Latitude: 280N Relative humidity (%) 30 50 Outdoor: Heating Cooling Moisture difference (gr/lb) 0.8 45.8 Dry bulb (°F) 42 93 Infiltration: Daily range (OF) - 16 ( M) Method Simplified Wet bulb (OF) - 76 Construction quality Average Wind speed (mph) 15.0 7.5 Fireplaces 0 Construction descriptions Or Area U-value Insul R Htg HTM Loss Clg HTM Gain fe BNhM'--•F tP-'F/BNh BNhM' BWh BtuhM' Btu Walls Blk wall, stucco ext, r-4 ext bd ins, 8" thk, 112" gypsum board int fnsh: n 435 0.201 4.1 5.57 2420 4.37 1900 Blk wall, stucco ext, r-4 ext bd ins, 8" thk, 1/2" gypsum board int fnsh a 80 0.201 4.1 5.57 446 4.37 350 s 501 0.201 4.1 5.57 2788 4.37 2189 w 276 0.201 4.1 5.57 1538 4.37 1208 all 1292 0.201 4.1 5.57 7192 4.37 5647 Partitions 12C-Osw: Frm wall, stucco ext, r-13 cav ins, 1/2" gypsum board int fnsh, 2"x4" wood frm, 16" o.c. stud Windows 2A-2om: 2 glazing, clr low-e outr, air gas, mtl no brk frm mat, Or innr, 1/4" gap, 1/8" thk; NFRC rated (SHGC=0.29); 50% drapes, medium; 1 ft overhang (5.25 It window ht, 1.17 ft sep.); 6.67 It head ht 2B-2fm: 2 glazing, clr low-e outr, air gas, mtl no brk trm mat, clr innr, 1/4" gap, 1/8" thk; NFRC rated (SHGC=0.29); 1 ft overhang (1.25 ft window ht, 1.17 It sep.); 6.67 ft head ht 2A-2om: 2 glazing, clr low-e outr, air gas, mtl no brk frm mat, clr innr, 1/4" gap, 1/8" thk; NFRC rated (SHGC=0.29); 50% drapes, medium; 1 ft overhang (6.25 ft window ht, 3.75 ft sep.); 6.67 ft head ht 2B-2fm: 2 glazing, clr low-e outr, air gas, mtl no brk frm mat, clr innr, 1/4" gap, 1/8" thk; NFRC rated (SHGC=0.29); 1 ft overhang (6.25 ft window ht, 3.75 It sep.); 6.67 ft head ht 2A-2omd: 2 glazing, clr low-e outr, air gas, mtl no brk frm mat, clr innr, 1/4" gap, 1/8" thk; NFRC rated (SHGC=0.29); 12 ft overhang (8 It window ht, 0.33 ft sep.); 6.67 ft head ht 2A-2om: 2 glazing, clr low-e outr, air gas, mtl no brk frm mat, clr innr, 1/4" gap, 1/8" thk; NFRC rated (SHGC=0.29); 9 ft overhang (5.25 ft window ht, 0.33 ft sep.); 6.67 ft head ht 304 0.091 13.0 2.52 767 1.45 441 n 16 0.350 0 9.69 157 10.5 169 n 17 0.350 0 9.69 161 10.5 174 s 49 0.350 0 9.69 471 10.7 522 w 65 0.350 0 9.69 628 29.0 1875 all 146 0.350 0 9.69 1417 18.8 2740 n 4 0.350 0 9.69 37 12.2 47 e 39 0.350 0 9.69 374 29.0 1116 e 39 0.350 0 9.69 374 34.0 1310 s 48 0.620 0 17.2 824 16.9 812 w 32 0.350 0 9.69 314 12.2 395 2018-May-29 14:15:04 t +jd- wrightsofFt' Right -Suite® Universal 2018 18.0.13 RSU23828 page 1 AC(>, ...agateDGRE\Lot28KensingtonReserveSeagateDGRE.rup Calc = MJ8 Front Door faces: E Doors 11 DO: Door, wd sc type Ceilings 1613-38ad: Attic ceiling, asphalt shingles root mat, r-38 ceil ins, 1/2" gypsum board int fnsh Floors 22A-tpl: Bg floor, light dry soil, on grade depth e 20 0.390 0 10.8 217 12.0 242 n 18 0.390 0 10.8 193 12.0 215 all 38 0.390 0 10.8 410 12.0 457 2048 0.026 38.0 0.72 1475 1.41 2893 174 0.989 0 27.4 4753 0 0 wrightsoft• 2018-May-2914:15:04 t Right -Suite® Universal 2018 18.0.13 RSU23828 Page 2 4CCl...agateDGRE\Lot28KensinglonReserveSeagateDGRE.rup Calc = MJB Front Door laces: E Project Summary Job: LotMensingtonReserv... wri htsoft' Y Date: 09-12-11 9 Entire House By: VMT DEL -AIR HEATING & AIR CONDITIONING 531 CODISCO WAY, SANFORD, FL 32771 Phone: 407-333-2665 Fax: 407-333-3853 Web: WWW.DEL-AIR.COM Prooect Information For: RYAN HOMES 3733 HANWORTH LOOP, SANFORD, FL 32773 Notes: L.S. 10-9-17 SRP RVSD 12-15-17 SRP L.S. 5-29-18 SRP Design Information Weather: Orlando/Jetport, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 93 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 18 OF Daily range M Relative humidity 50 % Moisture difference 46 gr/lb Heating Summary Structure 21030 Btuh Ducts 4206 Btuh Central vent (61 cfm) 1837 Btuh Outside air Humidification 0 Btuh Piping 0 Btuh Equipment load 27073 Btuh Infiltration Method Construction quality Fireplaces Area (ft2 Volume (ft3) Air changes/hour Equiv. AVF (cfm) Simplified Average 0 He ilig2034 Cooling 2034 19110 19110 0.32 0.16 102 51 Heating Equipment Summary Make Goodman Mfg. Trade GOODMAN; JANITROL; AMANA DISTI Model GSZ140361 K A H R I ref 8242629 Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat Capacity balance point = 37 OF Backup: 8.5 HSPF 32600 Btuh @ 470F 26 0 1160 cfm 0.046 cfm/Btuh 0.30 in H2O Input = 8 kW, Output = 26830 Btuh, 100 AFUE Sensible Cooling Equipment Load Sizing Structure 20986 Btuh Ducts 6296 Btuh Central vent (61 cfm) 1161 Btuh Outside air Blower 0 Btuh Use manufacturer's data y Rate/swing multiplier Equipment sensible load 1.00 28442 Btuh Latent Cooling Equipment Load Sizing Structure 2580 Btuh Ducts 1252 Btuh Central vent (61 cfm) 1877 Btuh Outside air Equipment latent load 5709 Btuh Equipment Total Load (Sen+Lat) 34151 Btuh Req. total capacity at 0.75 SHR 3.2 ton Cooling Equipment Summary Make Goodman Mfg. Trade GOODMAN; JANITROL; AMANA DISTI... Cond GSZ140361 K Coil ASPT47D14A AHRI ref 8242629 Efficiency 12.5 EER, 15 SEER Sensible cooling 26100 Btuh Latent cooling 8700 Btuh Total cooling 34800 Btuh Actual air flow 1160 cfm Air flow factor 0.043 cfm/Btuh Static pressure 0.30 in H2O Load sensible heat ratio 0.83 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. ti- wrightsoft- 2018-May-29 14:15:04 Right -Suite® Universal 2018 18 0.13 RSU23828 Page 1 ACCP.... agateDGRENLot28KensingtonReserveSeagateDGRE rup Calc = MJ8 Front Door faces: E wrightsoftRight-M Worksheet Entire House DEL - AIR HEATING & AIR CONDITIONING 531 CODISCO WAY, SANFORD, FL 32771 Phone: 407-333-2665 Fax: 407-333-3853 Web: WWW.DEL-AIR.COM Job: Lot28Kensing ton ReserveSe... Date: 09- 12-11 By: VMT 1 Room name Entire House Bdrm 3 2 Exposed wall 173.5 11 13.5 If 3 Room height 9.3 1t 9.3 It heat/cool 4 Room dimensions 13.5 x 13.5 ft 5 Room area 2047.5 fie 182.3 fiz Ty Construction Ul-value Or HTM Area (ft Load Area (ft Load I number BtutUftZ°F) Btuhrft2) or perimeter (ft) Btuh) or perimeter (ft) Btuh) Heal Cool Gross WP/S Heat Cool Gross N/P/S Heat Cool 6 W Blk wall, stucco ext 0.201 n 5.57 4.37 471 435 2420 1900 126 110 611 480 2A-2om 0.350 n 9.69 10.46 16 0 157 169 16 0 157 169 2A-2om 0.350 n 9.69 10.46 17 0 161 174 0 0 0 0 213-21m 0.350 n 9.69 12.19 4 0 37 47 0 0 0 0 1 1 Vk Blk wall, stucco ext 0.201 a 5.57 4.37 177 80 446 350 0 0 0 0 2A-2om 0.350 a 9.69 28.96 39 0 374 1116 0 0 0 0 2B-2fm 0.350 a 9.69 33.98 39 0 374 1310 0 0 0 0 11DO 0. 390 a 10.80 1203 20 20 217 242 0 0 0 0 Vy 81k wall, stucco ext 0.201 s 5.57 4.37 597 501 2788 2189 0 0 0 0 2A-2om 0.350 s 9.69 10.74 49 39 471 522 0 0 0 0 14-G 2A-2omd 0.620 s 17.17 16.92 48 48 824 812 0 0 0 0 Vy Blk wall, stucco ext 0.201 w 5.57 4.37 373 276 1538 120E 0 0 0 0 2A-2om 0.350 w 9.69 1219 32 32 314 395 0 0 0 0 Lam{( 2A- 2om 0.350 w 9.69 28.96 65 0 628 1875 0 0 0 0 P 12C- 0sw 0.091 252 1.45 322 304 767 441 126 126 318 183 11 DO 0.390 n 10.80 12.03 18 18 193 215 0 0 0 0 C 16B- 38ad 0.026 0.72 1.41 2048 2048 1475 2893 182 182 131 258 F 22A- tpl 0.989 27.40 0.00 2048 174 4753 0 182 14 370 0 6 c) AED excursion 0 99 Envelope loss/ gain 17936 15859 1587 991 12 a) Infltralion 3094 977 241 76 b) Room ventilation 0 0 0 0 13 1ntemal gains: Occupants @ 230 5 1150 0 0 Appliances/other 3000 0 Subtotal (lines 6 to 13) 21030 20986 1828 1067 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 21030 209B6 182E 1067 15 Duct loads 20'/ 30% 4206 30% 366 320 Total mom load 25236 2 j 2193 1387 Air required ( cfm) 1160 101 59 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. Fl 6_ = F lghtsoTV- 2018-May-29 14:15:04 9f\ ^--- Right - Suite® Universal 2018 18.0.13 RSU23828 Page 1 agateDGRE\Lot28KensingionReserveSeagateDGRE. rup Calc - M.18 Front Door faces: E wrightsoft• Right-M Worksheet Entire House DEL -AIR HEATING & AIR CONDITIONING 531 CODISCO WAY, SANFORD, FL32771 Phone:407-333.2665 Fax:407-333-3853 Web: WWW DEL-AIR.COM Job: Lot28Ken sing ton ReserveSe... Date: 09-12-11 By: VMT 1 Room name Msir WIC Msir WC 2 Exposed wall 5.5 it 0 it 3 Room height 9.3 it heat/cool 9.3 it heal/cool 4 Room dimensions 14.0 x 5.5 it 7.0 x 3.5 it 5 Room area 77.0 ft2 24.5 ft2 Ty Construction U-value Or HTM Area (fig Load Area (fig Load number B1ulVft2-"F) Btuh/fig or perimeter (it) Btuh) or perimeter (it) Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 V I Blk wall, stucco ext 0.201 n 5.57 4.37 51 51 286 224 0 0 0 0 2A- 20m 0.350 n 9.69 10.46 0 0 0 0 0 0 0 0 2A- 2om 0.350 n 9.69 10.46 0 0 0 0 0 0 0 0 I{ GG 2B- 21m 0.350 n 9.69 1219 0 0 0 0 0 0 0 0 1 1 Vh Blk wall, stucco ext 0.201 a 5.57 4.37 0 0 0 0 0 0 0 0 2A- 2om 0.350 a 9.69 28.96 0 0 0 0 0 0 0 0 2B- 21m 0.350 a 9.69 33.98 0 0 0 0 0 0 0 0 11D0 0.390 a 10.80 1203 0 0 0 0 0 0 0 0 yl Blk wall, stucco ext 0.201 s 5.57 4.37 0 0 0 0 0 0 0 0 2A- 2om 0.350 s 9.69 10.74 0 0 0 0 0 0 0 0 Imo_ C,G 2A- 2omd 0.620 s 17.17 16.92 0 0 0 0 0 0 0 0 V Blk wall, stucco ext 0.201 w 5.57 4.37 0 0 0 0 0 0 0 0 2A- 2om 0.350 w 9.69 1219 0 0 0 0 0 0 0 0 L-_ G 2A- 2om 0.350 w 9.69 28.96 0 0 0 0 0 0 0 0 PII 12C-Osw 0.091 252 1.45 0 0 0 0 0 0 0 0 L- D 11D0 0.390 n 10.80 1203 0 0 0 0 0 0 0 0 C 16B-38ad 0.026 0.72 1.41 77 77 55 109 25 25 18 35 F 22A-tpl 0.989 27.40 0.00 77 6 151 0 25 0 0 0 6 c) AED excursion 31 3 Envelope loss/gain 492 302 18 32 12 a) Infiltration 98 31 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/ other 0 0 Subtotal ( lines 6 to 13) 1 590 333 18 32 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 590 333 18 32 15 Duct loads 209/6 300/6 118 100 209/6 30/6 1 4 10 Total room load 708 433 21 41 Air required (cfm) 33 18 1 2 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. a r wrLo 2018-May-29 14:15:04 ACC'. Right - Suite® Universal 2018 18.0 13 RSU23828 Page 2 agateDGRENLot28KensingtonReserveSeagateDGRE. rup Calc = MJ8 Front Door faces E wrightsoft• Right-M Worksheet Entire House DEL -AIR HEATING & AIR CONDITIONING 531 CODISCO WAY, SANFORD, FL32771 Phone:407-333-2665 Fax: 407-333-3853 Web: WWW.DEL-AIR.COM Job: Lot28Ken sing ton ReserveSe... Date: 09-12-11 6y: VMT 1 Room name Mstr Bthrm Mstr Bdnn 2 Exposed wall 9.5 it 31.0 it 3 Room height 9.3 it heat/cool 9.3 it heal/cool 4 Room dimensions 1.0 x 87.5 ft 1.0 x 259.0 ft 5 Room area 87.5 W 259.0 fR Ty Construction U-value Or HTM Area (fig Load Area (ftg Load number BtutVftz°F) Btuft/ftg or perimeter (it) Btuh) or perimeter (h) Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 VhBlk wall, stucco ext 0.201 n 5.57 4.37 89 85 472 371 159 142 791 621 2A- 20m 0.350 n 9.69 10.46 0 0 0 0 0 0 0 0 2A- 2om 0.350 n 9.69 10.46 0 0 0 0 17 0 161 174 2B- 2fm 0.350 n 9.69 1219 4 0 37 47 0 0 0 0 11 VhBlk wall, stucco ext 0.201 a 5.57 4.37 0 0 0 0 0 0 0 0 2A- 2om 0.350 a 9.69 28.96 0 0 0 0 0 0 0 0 2B- 21m 0.350 a 9.69 33.98 0 0 0 0 0 0 0 0 11 DO 0.390 a 10.80 12-03 0 0 0 0 0 0 0 0 Vjl Blk wall, stucco ext 0.201 s 5.57 4.37 0 0 0 0 0 0 0 0 2A- 2om 0.350 s 9.69 10.74 0 0 0 0 0 0 0 0 ll--G 2A- 2omd 0.620 s 17.17 16.92 0 0 0 0 0 0 0 0 V Blk wall, stucco ext 0.201 w 5.57 4.37 0 0 0 0 131 98 547 430 2A- 2om 0.350 w 9.69 1219 0 0 0 0 0 0 0 0 2A- 2om 0.350 w 9.69 28.96 0 0 0 0 32 0 314 938 PII 12C-0sw 0.091 252 1.45 0 0 0 0 0 0 0 0 D 11DO 0.390 n 10.80 1203 0 0 0 0 0 0 0 0 C 1613-38ad 0.026 0.72 1.41 88 88 63 124 259 259 187 366 F 22A-tpl 0.989 27.40 0.00 88 10 260 0 259 31 849 0 6 c) AED excursion 51 147 Envelope loss/gain 833 491 2849 2675 12 a) Infiltration 169 54 553 175 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 1 230 Applanceslother 0 600 Subtotal ( lines 6 to 13) 1002 544 3402 3680 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 1002 544 3402 3680 1T; z 2D'/ 30'/6 200 163 20% 30% 680 1104 load 1203 708 4082 4784 cfm) 1 1 55 30 188 203 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrlghtsoft- 2018-May-2914:15:04 Right - Suite® Universal 2018 18.0.13 RSU23828 Page 3 agateDGRE\ Lot28KensingtonReserveSeagateDGRE.rup Calc = MJ8 Front Door faces: E 1- wrightsoft' Right-JO Worksheet Entire House DEL -AIR HEATING & AIR CONDITIONING 531 CODISCO WAY, SANFORD, FL32771 Phone:407-333-2665 Fax:407-333-3853 Web: WWW.DEL-AIR.COM Job: Lot28Kensing ton ReserveSe... Date: 09-12-11 By: VMT 1 2 3 4 5 Room name Exposed wall Room height Room dimensions Room area GREAT RM 29. 0 It 9. 3 ft heaYcool 1. 0 x 658.6 It 658. 6 ft2 Kitchen/ Nook 34. 0 If 9. 3 ft heal/cool 1. 0 x 277.4 If 277. 4 ftz Ty Construction number U- value BtufditZ• F) Or HTM Btut1/ ftz) Area ( ftq or perimeter (ft) Load Btuh) Area ( III or perimeter (ft) Load Btuh) Heat Cod Gross N/P/S Heat Cool Gross I N/P/S Heat cool 6 11 Vjl Blk wall, stucco ext 2A- 2om 2A- 2om 2B- 2f m Blk wall, stucco ext 2A- 2om 2B- 21m 11 DO Blk wall, stucco ext 2A- 2om 2A- 2omd Blk wall, stucco ext 2A- 2om 2A- 2om 12C- Osw 11D0 16B- 38ad 22A- tpl 0. 201 0. 350 0. 350 0. 350 0. 201 0. 350 0. 350 0. 390 0. 201 0. 350 0. 620 0. 201 0. 350 0. 350 0. 091 0. 390 0. 026 0. 989 n n n n a a a a s s s w w w n 5. 57 9. 69 9. 69 9. 69 5. 57 9. 69 9. 69 10. 80 5. 57 9. 69 17. 17 5. 57 9. 69 9. 69 2. 52 10. 80 0. 72 27. 40 4. 37 10. 46 10. 46 12. 19 4. 37 28. 96 33. 98 12. 03 4. 37 10. 74 16. 92 4. 37 12. 19 28. 96 1. 45 12. 03 1. 41 0. 00 0 0 0 0 47 0 0 20 84 0 48 140 0 32 196 18 659 659 0 0 0 0 27 0 0 20 36 0 48 108 0 0 178 18 659 29 0 0 0 0 148 0 0 217 200 0 824 599 0 314 449 193 474 794 0 0 0 0 116 0 0 242 157 0 812 471 0 938 259 215 931 0 0 0 0 0 0 0 0 0 215 32 0 103 32 0 0 0 277 277 0 0 0 0 0 0 0 0 182 26 0 70 32 0 0 0 277 34 0 0 0 0 0 0 0 0 1015 314 0 391 314 0 0 0 200 931 0 0 0 0 0 0 0 0 797 348 0 307 395 0 0 0 392 0 I-- GG V L P C F 6 c) AED excursion 110 152 Envelope loss/gain 4214 4= 3165 2391 12 a) Infiltration b) Room ventilation 517 0 163 0 606 0 192 0 13 Internal gains: Occupants @ 230 Appliances/ other 4 920 0 0 0 1200 Subtotal ( lines 6 to 13) 4731 5113 3772 3783 14 15 Less external load Less transfer RedistnWion Subtotal Duct loads 20 M. 30° 0 0 0 4731 946 0 0 0 5113 1534 20°/ 30° 0 0 0 3772 754 0 0 0 3783 1135 Total room load Air required (cfm) 5677 261 6647 283 1 4526 1 208 4917 209 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wr gF!tsoft- 2018-May-29 14:15,04 A Right - Suite® Universal 2018 18.0.13 RSU23828 Page 4 agateDGRE1Lot28KensingtonReserveSeagateDGRE. rup Calc = MJ8 Front Door faces: E wrightsoft' Right-JO Worksheet Entire House DEL -AIR HEATING & AIR CONDITIONING 531 CODISCO WAY, SANFORD, FL 32771 Phone: 407-333-2665 Fax: 407-333-3853 Web: WWW.DEL-AIR.COM Job: Lot28Kensing ton ReserveSe... Date: 09-12-11 By: • VMT 1 Room name Bdrm 4 Bdrm 2 2 Exposed wall 10.5 ft 34.0 it 3 Room height 9.3 ft heat/cool 9.3 It heal/cool 4 Room dimensions 13.5 x 10.5 ft 1.0 x 195.0 ft 5 Room area 141.8 f12 195.0 f12 Ty Construction U-value Or HTM Area (ft Load Area (ft9 Load number Btuh/ftI'F) Btuhr1112) or perimeter (ft) Btuh) or perimeter (fl) Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W Blk wall, stucco exi 0.201 n 5.57 4.37 0 0 0 0 47 47 260 204 2A- 2om 0.350 n 9.69 10.46 0 0 0 0 0 0 0 0 2A- 2om 0.350 n 9.69 10.46 0 0 0 0 0 0 0 0 2B- 2fm 0.350 n 9.69 12.19 0 0 0 0 0 0 0 0 11 VhBlk wall, stucco exi 0.201 a 5.57 4.37 0 0 0 0 131 54 298 234 2A- 2om 0.350 a 9.69 28.96 0 0 0 0 39 0 374 1116 2B- 2fm 0.350 a 9.69 33.98 0 0 0 0 39 0 374 1310 11DO 0.390 a 10.80 12.03 0 0 0 0 0 0 0 0 Blk wall, stucco ext 0.2D1 s 5.57 4.37 98 82 456 358 140 140 779 612 2A- 2om 0.350 s 9.69 10.74 16 13 157 174 0 0 0 0 lit----- 2 2A-2omd 0.620 s 17.17 16.92 0 0 0 0 0 0 0 0 Blk wall, stucco ext 0.201 w 5.57 4.37 0 0 0 0 0 0 0 0 2A- 2om 0.350 w 9.69 1219 0 0 0 0 0 0 0 0 2A- 2om 0.350 w 9.69 28.96 0 0 0 0 0 0 0 0 P 12C-0sw 0.091 2.52 1.45 0 0 0 0 0 0 0 0 11D0 0.390 n 10.80 1203 0 0 0 0 0 0 0 0 C 16B-38ad O.026 0.72 1.41 142 142 102 200 195 195 140 276 F 22A-1p1 0.989 27.40 0.00 142 11 288 0 195 34 931 0 6 c) AED excursion 99 187 Envelope loss/gain 1002 633 3157 3939 12 a) .Irdiltration 187 59 606 192 b) Room ventilation 0 0 0 0 13 Intemal gains: Occupants @ 230 0 0 0 0 Appliances/ other 600 1 0 Subtotal ( lines 6 to 13) 1189 1292 3763 4130 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 1189 1292 3763 4130 15 Duct loads 20% 30% 238 388 2D'/ 309/6 753 1239 Total room load 1427 1680 4516 53119 Air required (cfm) 1 66 71 208 228 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrlgtitsofY- 2018-May-2914,15.04 Right - Suite® Universal 2018 18.0.13 RSU23828 Page 5 agateDGRElLot28KensingtonReserveSeagateDGRE. rup Calc - MJ8 Front Door faces: E F- wrightsoft' Right-J® Worksheet Entire House DEL -AIR HEATING & AIR CONDITIONING 531 CODISCO WAY, SANFORD, FL 32771 Phone: 407-333-2665 Fax. 407-333-3853 Web: WWW.DEL-AIR.COM Job: Lot Men sing tonReserveSe... Date: 09-12-11 By: VMT 1 2 3 4 5 Room name Exposed wall Room height Room dimensions Room area Bth 1 6.5 It 9.3 it heat/cool 1.0 x 106.0 ft 106.0 f12 Bih 2 0 It 9.3 It heat/cool 7.0 x 5.5 ft 38.5 ft2 Ty Construction number Ul-value Btutditz'F) Or HTM Btuhlftq Area (fig or perimeter (ft) Load Btuh) Area (fig or perimeter (ft) Load Btuh) Heat Co.[ Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6V[ jBlk 1 1 wall, stucco ext 2A-2om 2A-2om 2B-2fm Blk wall, stucco ext 2A-2om 2B-2fm 11 DO Blk wall, stucco ext 2A-2om 2A-2cmd Blk wall, stucco ext 2A-2om 2A-2om 12C-Osw 0.201 0.350 0.350 0.350 0.201 0.350 0.350 0.390 0.201 0.350 0.620 0.201 0.350 0.350 0.091 n n n n a a a a s s s w w w 5.57 9.69 9.69 9.69 5.57 9.69 9.69 10.80 5.57 9.69 17.17 5.57 9.69 9.69 2-52 4.37 10.46 10.46 1219 4.37 28.96 33.98 1203 4.37 10.74 16.92 4.37 1219 28.96 1.45 0 0 0 0 0 0 0 0 61 0 0 0 0 0 0 0 0 0 0 0 0 0 0 61 0 0 0 0 0 0 l0 0 0 0 0 0 0 0 338 0 0 0 0 0 0 0 0 0 0 0 0 0 0 265 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Vh Vy IG PI L--D 11D0 16B-38ad 22A-tpl 0.390 0.026 0.989 n 10.80 0.72 27.40 1203 1.41 0.00 0 106 106 0 106 7 0 76 178 0 150 0 0 39 39 0 39 0 0 28 0 0 54 0 C F 6 c) AED excursion 38 56 Envelope loss/gain 592 377 28 1 12 a) Infiltration 116 37 0 0 b) Room ventilation 0 0 0 0 13 Intemal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 600 Subtotal (lines 6 to 13) 708 413 28 599 Less external load 0 0 0 0 14 Less transfer Redistribution Subtotal 0 0 708 0 0 413 0 0 28 0 0 599 15 Duct loads 20% 3D9/6 142 124 200/6 309/6 6 180 Total room load Air required (cfm) 850 39 537 23 33 2 778 33 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. j.t wrlgt tsoTt- 2018-May-2914:15:04 A - Right -Suite® Universal 2018 18.0.13 RSU23828 Page 6 agateDGRBLot28KensingtonReserveSeagateDGRE.rup Calc - MJ8 Front Door faces: E Duct System SJob: LotMensingtonReserv... wrightsofte yem Summary Date: 09-12-11 Entire House By: VW DEL - AIR HEATING & AIR CONDITIONING 531 CODISCO WAY, SANFORD, FL32771 Phone:407-333-2665 Fax: 407-333-3853 Web: WWW.DEL-AIR.COM Project• • For: RYAN HOMES 3733 HANWORTH LOOP, SAN FORD, FL 32773 External static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual air flow Total effective length (TEL) Heating 0. 30 in H2O 0. 06 in H2O 0. 24 in H2O 0. 120 / 0.120 in H2O 0. 171 in/100ft 1160 cfm Cooling 0. 30 in H2O 0. 06 in H2O 0. 24 in H2O 0. 120 / 0.120 in H 20 0. 171 in/100ft 1160 cfm 140 ft Supply Branch Detail Table Name Design Btuh) Htg cfm) Clg cfm) Design FR Diam in) H x W in) Duct Mall Actual Ln ( ft) Ftg. Egv Ln ( ft) Trunk Bann 2 c 5369 208 228 0.212 9.0 Ox 0 VIFx 28.4 85.0 st2 Bdrm 3 h 2193 101 59 0.319 6.0 Ox 0 VIFx 5.1 70.0 Bdrm 4 c 1680 66 71 0.225 6.0 Ox 0 VIFx 21.7 85.0 st2 Btht- A h 850 39 23 0.221 4.0 Ox0 VIFx 23.5 85.0 st2 Bth 2 C 778 2 33 0.310 4.0 Ox 0 VIFx 7.4 70.0 GREAT RM c 2216 87 94 0.171 6.0 Ox 0 VIFx 40.0 100.0 st3 GREAT RM-A c 2216 87 94 0.171 6.0 Ox0 VIFx 40.3 100.0 st3 GREAT RM-B c 2216 87 94 0.214 6.0 Ox 0 VIFx 27.2 85.0 SO Ktchen/ Nook c 2459 104 105 0.207 7.0 Ox0 VIFx 31.1 85.0 st2 K; tchen/Nook-A C 2459 104 105 0.198 7.0 Ox 0 VIFx 36.2 85.0 st2 Mstr Bdrm c 4784 188 203 0.174 8.0 Ox 0 VIFx 37.9 100.0 st3 Mstr Bthrm h 1203 55 30 0.222 5.0 Ox 0 VIFx 23.2 85.0 st1 Mstr WC c 41 1 2 0.226 4.0 Ox 0 VIFx 21.2 85.0 st1 Mstr WIC h 708 33 18 0.226 4.0 Ox 0 VIFx 21.4 85.0 stl Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type cfm) cfm) FR fpm) in) in) Material Trunk st3 Peak AVF 362 392 0.171 499 12.0 0 x 0 VinlFlx SO st1 Peak AVF 537 536 0.171 503 14.0 0 x 0 VinlFlx st2 Peak AVF 520 532 0.198 497 14.0 0 x 0 VinlFlx V~+ Right - Suite® Universal 2018 18.0.13 RSU23828 ACCA... agateDGRE\Lot28KensingtonReserveSeagateDGRE.rup Calc = MJ8 Front Door faces 2018- May-29 14:15:05 Page 1 Return Branch. Detail Table Name Grille Size (in) Htg cfm) ClgI (cfm) TEL ft) Design FIR Veloc fpm) Diam in) H x W in) Stud/Joist Opening (in) Duct Matl Trunk rb1 Ox 0 1160 1160 0 0 0 0 Ox 0 VIFx wrightsoR• 2018-May-29 14:15:05 Right -Suite® Universal 2018 18.0.13 RSU23828 page 2 ACCK...agateDGRE1Lot28KensingtonReserveSeagateDGRE.rup Calc = MJ8 Front Door laces. E 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: Lot28KensingtonReserveSeagateDGRE Builder Name: RYAN HOMES Street: 3733 HANWORTH LOOP Permit Office: SANFORD City, State, Zip: SANFORD , FL, 32773 Permit Number: Owner: Jurisdiction: 691500 Design Location: FL, Orlando COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. requirements Breaks or joints in the air barrier shall be sealed. The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit Ceiling/attic the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. The junction of the foundation and sill plate shall be sealed. Cavities within comers and headers of frame walls Walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity with sealed. a material having a thermal resistance of R-3 per inch Knee walls shall be sealed. minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that on Narrow cavities installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spac 3s. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind D*D'no and wwrina. Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids betweenfire prinkler cover plates and walls or ce0I0nos--.-- .-- a. In addition, inspection of log walls shall be in accordance with the provisions or icc-4uu. 5/29/2018 2:20 PM EnergyGauge® USA - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 aa-ea ae-e l as -ea a-e I I IATAI I wee ECdMW I =''4- rr- I I 95 Pq I I0x6 Iwcd Z 61, 01 d A- a GRBA7 RY. M U w.-4. ci.0 Z 16x16 rn O p 14x Iwcd 01 O + e a - a 205 g L c O c 105 4' 8' O C$ L S 12x6 Iwcd o 99 3 \ O • I0x6 Iwcd z 3-P ('' 6- Jill = d Ij j II 12' X Y-4' • I III I t -4' J O I III I I V-4' OII I I DINING x S c x6 w III II12x6 1 rc = I I T-4' CLG. II 105 4' lOx6 Iwcd 6 95 I I 7' I 9'-4' CLGL 20 I w-a = I Bx4 Iwcd m ----- II u I ' I BDRM.#A V-4' Q.& I m -{• I W-4' 0.G: 70 I 4 6' I0x6 Iwcd d C P11 lox 6, I II 60 U d d $ I 4• 3 U( 4- I Z5 \ \0 20x6 rag 4- 3C7N O 0 I I P O [ --- Il -- d L 20x r = _ _ _ - - - 24 IB rag 4 1Z O 9'- 4' I I O PADS 4 A41 II I I wryer uc t0 roof c iwc /dr er vent bo A 2-cAit GARAGE J J 91 - e {• ate J Z vI Q 20x6 rag 3 z U Q A 3. 0 TON V/5KV @240V IPH Pqq 230 IBx13 plen LL- X 14 Iwcd platforn by >- (U zb-ew ae-ew i Z-1 bldr (U Pq 1 rsee sae WWCL&- - Ir' ok'- 0• ox NOTE TO BUDL DER,MUST PROVIDE UNRESTRICTED 1 INCH UNDERCUT BELOV DOIIRS TO HABITABLE ROOMS Transfer ducts/ grills sized In conpUance with Florida Residential Building Code-M1602.4 balanced return air. EXCEPTIONS 1- 3 Rating Must have a minimum clearance of 4 Inches around the air handler per the State Energy code. All duct has an r=6 insulation value. v o_ m N O CO Ctc,\ O O O S N m Z 0 O_ N 00 w w ON O W W 41 V Z a E z O d CU 0) V) r,- - d d Z o i, 01 00 W o LL- 0 0 ( LJ Y r-I V) z O N m LU z J Q H M Q D J O Z) QQ m CL J Vn 0 0 ef }, At B•Jb- prtosN / fry Ova Diu V 3 1 1 -- 4 Z n n 0 1 eo co f•l' `'A - o r • 3 s u RECORD COPY DESCRIPTION AS I FURNISHED: Lot 28, KENSINGTON RESERVE, os recorded in Plat Book 81, Poges 86 through 92, Public Records of Seminole County, Florida. PLOT PLAN FOR CERTIFIED TO: Ryan Homes/NVR Inc. LOT 27 A P.C.) 1 LOT 43 1 44 S 00°19'09" E 60.00' s. 24.80' 24.80' LOT 28 I 11.0' - 29.0 10.00' LANAI c6 10.00' 1 1.0 W o0 iri PROPOSED RESIDENCE 53 MODEL: SEAGATE ELEV.D 2CAR GARAGE RIGHT 0 o Into co U) A/C 5.0ENTRY o o 14. 0' Lo to. 00' 21.0' 10. 00' WAX 16' DRIVE 26. 20' 25.20 5.20' LOT 42 1 I W 7 6. 50' LOT 29 56'- ems u I 10' um. ESMT. WALK 11 1I I/_ CURR zOWN _ - :5- ^Tt-grr3 r8 IIS 00019'09" E 60. 00' Ok to construct single family home HANWORTH LOOP with setbacks and impervious area 50' PRIVATE ROAD shown on plan. 49 • q Seaga - " D , GR PROPOSED = FINSHED SPOT GRADE ELEVATIONS PLOT PLAN ONLY NOT A SURVEY FRONT•= 25'V PER DRAINAGE PLANS I PLOT PLAN AREA CALCULATIONS REAR = 20- Lr= PROPOSED DRAINAGE FLOW 0 IMPERVIOUS COVERAGE = 3,0261 SQUARE FEET OR 43.9R SIDE 5' FOR 40' LOTS LOT GRADING TYPE A Q05 LOT CONTAINS 6,900t SQUARE FEET SIDE 7.5' FOR 60' LOTS QO LIVING AREA CONTAINS 2,463t SQUARE FEET SIDE 10' FOR 75' LOTS PROPOSED FINISH FLOOR PE7 PLANS - 27.4 CONE LANAI/PORCH CONTAINS 563t SQUARE FEET SIDE STREET - 25' CR USLTNM T YE'R -,S'CO TT L.JL. A SASO C. , INC• - LAND SURVEYORS LEGEND - LEGEND - P . PLAT PDL. •POINT ON LINO 5400 E. COLONIAL OR. ORLANDO, FL. 32807 (407)-277-3232 FAX (407)-658-1436 F PLAT TYP. • TY ICAL NOTES: IP. IRON PIPE PRL POINT OT REVERS[ CURVATURE 1. THE UNDERSIGNED DOES HEREBY CERNY THAT THIS SURVEY MEETS THE STANDARDS OF PRACTICE SET FORTH BY THE FLORIDA BOARD OF IA. IRON ROD PL.- POINT OF COMPOUND CURVATURE PROFESSIONAL SURVEYORS AND MAPPERS UJ CHAPTER '.LT-17 FLORIDA ADMINISTRATIVE CODE PURSUANT TO SECTION 472.027, FLORIDA STATUES SE CONCRETE MONUMENT 459RAO RADIAL 2. UNLESS EMBOSSED WITH SURVEYOR'S SIGNATURE AND ORIGINAL RAISED SEAL THIS SURVEY MAP OR COPIES ARE NOT VALID. SET I.R. • 1/C E ./RCP 459i V NON - RADIAL REC. COVERED I vP. • vITNESi POINT J. THIS SURVEY WAS PREPARED FROM TITLE INFORMATION FURNISHED TO THE SURVEYOR THERE MAY BE OTHER RESTRICTIONS ROD. • PO[NT OF BEGINNING [AEG CALCULATED OR E:ISEMFNTS THAT AFFECT THIS PROPERTY. Par_ • POINT OF COMMENCEMENT PRx PERMANENT REFERENCE MONWICNT 4. NO UNDERGROUND IMPROVEMENTS HAVE BEEN LOCATED UNLESS OTHERWISE SHOWN. FF. FINISHED FLGOR ELEVATIW 5, iNUs SURVEY IS PREPARED FOIL ME SOLE BENEFIT OF THOSE CFRTIFlID ro AND SHOUlD NOT Bf RflIEO UPON BY ANY OTHER ENTITY. ItNAILLD1SKBSA • BUILDING SETBACK LING B, DIMENSIONS SHOWN FOR THE LOCATION OF IMPROVEMENTS HEREON SHOULD NOT BE USED TO RECONSTRUCT BOUNDARY LINES ItRIGHT-CT-VAY BA • BENCHMARK ESMT. • EASEMENT B.B. BASE BEARING 7. BEARINGS, ARE BASED ASSUMED DATUM AND ON THE LINE SHOWN AS EASE BEARING (B.B) DR' IM. • DRAINAGE E. ELEVATIONS, IF SHORN, ARE BASED ON NATIONAL GEODETIC VERTICAL DATUM OF 1929, UNLESS OTHERWISE NOTED. UTIL. UTILITY 9, CERTIFICLTE OF AUTHORIZATION No. 459E. CLFC. CHAIN LINK FCNCC VOFG • VOOD FENCE C/ B • CONCRETE ROCK SCALE N- 1 • 20 BYI ••• P, C, POINT OF CURVATURE P. T. • POINT OF TANGENCY CERTIFIED BY: DATE R SC. RADIUS TION PLOT PLAN 05-27 -18 3163- 18 L ARC LENGTH. D • DELTA GB. • G iORD BEARING NORTH TH15 BU1LOlNC/PROPERTY DOES NOT LIE WITHIN - rNTHE ESTABLISHED100YEARnowPLANEASPERFTRM- TO MEYER, R.L.S. j 4714 ZONE • X' MAP j 121170009OF (09-28-07) R.L.S j 480f RECORD COPY I n City of Sanford Building and Fire Prevention ProductnSANFORD Specification Form 2854Permit # Project Location Address As required by Florida Statute 553.842 and Florida Administrative Code 9N-3, please provide the information and product approval number(s) on the building components listed below if they are to be utilized on the construction project for which you are applying for a building permit. We recommend that you contact your local product supplier should you not know the product approval number for any of the applicable listed products. Be aware that windows, skylights, and exterior doors must be tested in accordance with the Florida Building Code, Section 1714.5. More information about Statewide Product Approval can be obtained at www.floridabuildin-g.org. The following information must be available on the jobsite for inspections: 1. This entire product approval form 2. A copy of the manufacturer's installation details and requirements for each product. Category / Subcategory Manufacturer Product Description Florida Approval # include decimal 1. Exterior Doors Swinging Therma Tru Smooth Star 20461-R3 Sliding Ply Gem 4780 SGD 14634-R3 Sectional Wayne Dalton 9100 - #0600 / #0607 9147.11 / 8174.2 - R12 Roll U Automatic Other 2. Windows Single Hung Ply Gem 1500 16103 Horizontal Slider Casement Double Hun Fixed Ply Gem 1500 16104 Awning Pass Through Projected Mullions Ply Gem 1500 16118 Wind Breaker Dual Action Other June 2014 Category/Subcategory Manufacturer Product Descri tion Florida Approval # includin decimal 3. Panel Walls Siding Soffits Aluminum Coils Inc. Aluminum Soffit Panels 12194 - R7 Storefronts Curtain Walls Wall Louver Glass block Membrane Greenhouse E.P.S Composite Panels Other 4. Roofing Products Asphalt Shingles CertainTeed Corp. CertainTeed Asphalt Roofing Shingles 5444 - R12 Underla ments InterWrap Inc. Rhino Roof Underlayment 15216 - R3 Roofing Fasteners Nonstructural Metal Roofing Wood Shakes and Shingles Roofing tiles Roofing Insulation Waterproofing Built up roofing System Modified Bitumen Single Ply Roof Systems Roofing slate Cements/ Adhesives / Coating Liquid Applied Roofing Systems Roof Tile adhesive Spray Applied Polyurethane Roofing E.P.S. Roof Panels Roof Vents Millenium Metals Inc. MMI - 213 Off Ridge Vent 19567 - R1 Other June 2014 Category / Subcategory Manufacturer Product Description Florida Approval # include decimal 5. Shutters Accordion Bahama Colonial Roll u Equipment Other 6. Skylights Skylights Other 7. Structural Components Wood Connectors / Anchors Truss Plates Engineered Lumber Railing Coolers/Freezers Concrete Admixtures Precast Lintels Lott's Concrete Products Lintel 17867 - R1 Insulation Forms Plastics Deck / Roof Wall Prefab Sheds Other 8. New Exterior Envelope Products Applicant's Signature Applicant's Name Tracy McDonald Please Print) June 2014 ad A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD.. FORT PIERCE, FL 34946 PH: 772-409-1010 FX: 772-409-1015 www.AlTruss.com TRUSS ENGINEERING BUILDER: RYAN HOMES o W% PROJECT: KENSINGTON RESERVE °D N o b COUNTY: SEMINOLE co L" LOT/BLK/MODEL: LOT.28 / MODEL:SEAGATE V4 / ELEV:D / GAR If JOB#: 72420 MASTER#: WRCSG4D9 OPTIONS: 9-4 CEILING Lumber design values are in accordance with ANSI/TPI 1-2007 section 6.3 t - A-1 ROOF These truss designs rely on lumber values established by others. TRUSSES A FLORIDA CORPORATION RE: Job WRCSG4D9 JOB #72420 Site Information: Customer Info: RYAN HOMES Project Name: Lot/Block: LOT #28 Address: City: Model: SEAGATE v4 "D" Subdivision: County: VARIES A-1 Roof Trusses 4451 St Lucie Blvd Fort Pierce, FL 34946 State: FL Name Address and License # of Structural Engineer of Record, If there is one, for the building. Name: License #: Address: City: General Truss Engineering Criteria Design Loads (Individual Truss Design Drawings Show Special Loading Conditions): Design Code: FBC2017/TP12014 Design Program: MiTek 20/20 8.1 Wind Code: ASCE 7-10 Wind Speed: 150 MPH Roof Load: 40.0 psf Floor Load: 0.0 psf This package includes -99 individual, dated Truss Design Drawings and 16 Additional Drawings. With my seal affixed to this sheet, I hereby certify that I am the Truss Design Engineer and this index sheet conforms to 61G15-31.003,section 5 of the Florida Board of Professional Engineers Rules. No. Seal # Truss Name Date No. Seal # Truss Name Date No. Seal # Truss Name Date 1 A0182836 A09 1/26/18 13 A0182848 C01 1/26/18 25 IA0182860 E04 1/26/18 2 A0182837 A10 1/26/18 14 A0182849 CJ1 1/26/18 26 A0182861 HJ3 1/26/18 3 A0182838 All 1/26/18 15 A0182850 CJ3 1/26/18 27 A0182862 HJ6 1/26/18 4 A0182839 Al2 1/26/18 16 A0182851 CJ3A 1/26/18 28 A0182863 HJ7 1/26/18 5 A0182840 A13 1/26/18 17 A0182852 CJ5 1/26/18 29 A0182864 J3 1/26/18 6 A0182841 A13H 1/26/18 18 A0182853 CJ5A 1/26/18 30 IA0182865 A 1/26/18 7 A0182842 A14D 1/26/18 19 A0182854 D01 1/26/18 31 A0182866 J7 1/26/18 8 IA0182843 A14H 1/26/18 20 IA0182855 D02 1/26/18 32 A0182867 J713 1/26/18 9 IA0182844 A15D 1/26/18 21 A0182856 D03 1/26/18 33 A0182868 VM2 1/26/18 10 A0182845 A15H 1/26/18 22 A0182857 D04 1/26/18 34 A0182869 VM4 1/26/18 11 A0182846 A16D 1/26/18 23 A0182858 1 005 1 1/26/18 11.3.5 IA0182870 I VM6 1 1/26/18 12 A0182847 A16H 1 1/26/18 24 A0182859 I E03 1 1/26/18 1136 1 STDL01 I STD. DETAIL 1 1/26118 The truss drawing(s) referenced have been prepared by MiTek Industries, Inc. under my direct supervision based on the parameters provided by A-1 Koot I russes, Ltd. Truss Design Engineer's Name: Anthony Tombo III My license renewal date for the state of Florida is February 28,2019. NOTE:The seal on these drawings indicate acceptance of professional engineering responsibility solely for the truss components shown. IIIIIIIIffff E N .0 The suitability and use of components for any particular building is the responsibility of the `3: • ` •' building designer, perANSI/TPI-1 Sec. 2. = i; NO 800e3 6,1 The Truss Design Drawing(s)(TDD[s)) referenced have been prepared based on the construction documents (also referred to at times as 'Structural Engineering Documents) provided by the Building Designer indicating the nature and character of the work. • The design criteria therein have been transferred to Anthony Tombo III PE by [Al Roof • Trusses or specific location]. These TDDs (also referred to at times as 'Structural Digitally signed by i '. • Engineering Documents) are specialty structural component designs and maybe 'q o n T. Tombo, III .• %10 'ON, pro]ecrs deferred or phased submittals. As a Truss Design Engineer (i.e., Specla yR " , 1 ly ON: c-US, st=Florida,o A •• ••••.•• , Pierce, o-Whole House 7 Engineer), the sepal here and on the TD9 represents an acceptance of professional TO m bo, Tornboelll9 cn=Anthony #i,s,otN of ` •`, engineering responsibility for the design of the single Truss depicted on the TDD o Th 1 1 1to Building Designer is responsible for and shall coordinate and review the TDDs for compatibility with their written engineering requirements. Please review all TDDs}¢ all Anthont'919R4d8gltlatP.E. SERIAL related notes. Date:2018.01.26 14:55: 8 05.00' 36 B A2 2100 00 00 00 4C 12 87 DF Page 1 of 2 Lumber design values are in accordance with ANSI/TPI 1-2007 section 6.3 A-1 ROOF These truss designs rely on lumber values established by others. 46#MTRUSSES ' A FLORIDA CORPORATION RE: Job WRCSG4D9 No. Seal # Truss Name Date 37 STDL02 STD. DETAIL 1/26/18 38 STDL03 STD. DETAIL 1/26/18 39 STDL04 STD. DETAIL 1/26/18 40 STDL05 STD. DETAIL 1/26/18 41 STDL06 STD. DETAIL 1/26/18 42 STDL07 STD. DETAIL 1/26/18 43 STDL08 STD. DETAIL 1/26/18 44 STDL09 STD. DETAIL 1/26/18 45 STDL10 STD. DETAIL 1/26/18 46 STDL11 STD. DETAIL 1/26/18 47 STDL12 STD. DETAIL 1/26/18 48 STDL13 STD. DETAIL 1/26/18 49 STDL14 STD. DETAIL 1/26/18 50 STDL15 STD. DETAIL 1/26/18 51 STDL16 STD. DETAIL 1/26/18 Page 2 of 2 Job Truss Truss Type Oty Ply RYAN HOMES / SEAGATE v4 A0182836 WRCSG4Q9 A09 Common 12 1 1 Job Reference (optional) Al Roof Trusses, Fort Pierce, FL 34946, design@allruss.cem Run: 8.120 s Nov a 2u1 / runt:. 8.1 zu s NOV 1z zui i mi I eK industries, Inc. noon Dec i i 1 1:35:2 i 20 i r rage I ID:UumEBPzOXokuwJ2P5W7E2TyuPl h-gMLhlvjgKBzmzmRgbhTZGV_5Uh3JIC51UZsGAGyA3Uq 7-2-2 14-2-2 20-0-0 25 9-14 32-9 14 40-0 0 1 0 7-2-2 6-11-15 5-9-14 5 9-14 6 11-15 7-2-2 - 010 5x6 = 5.00 12 Dead Load Defl. = 5/16 in 10 10 14 co t< 3x4 4x6 = 3x8 = 4x6 = 3x4 = 3x6 = 3x6 = 10-0-5 20-0-0 29-11-11 40-0-0 10-0-5 9-11-11 9-11-11 10-0-5 LOADING(psf) SPACING- 2-M CSI. DEFL. in (loc) Weft Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.74 Vert(LL) 0.33 14-16 999 240 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.71 Vert(CT) 0.63 14-16 757 180 BCLL 0.0 ' Rep Stress Incr YES WB 0.83 Horz(CT) 0.14 10 n/a n/a BCDL 10.0 Code FBC20171TP12014 Matrix -MS Weight: 196 lb FT = 0% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP M 30 WEBS 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 6-1-13 oc bracing. WEBS 1 Row at midpt 7-14, 5-14 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 2 = 1660/0-8-0 (min. 0-1-15) 10 = 1660/0-8-0 (min. 0-1-15) Max Horz 2 = 156(LC 13) Max Uplift 2 = 490(LC 12) 10 = 490(LC 13) Max Grav 2 = 1660(LC 1) 10 = 1660(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-23=-3488/1622,3-23=-3444/1642, 3-4=-3184/1508, 4-5=-3099/1524, 5-24=-2175/1157, 6-24=-2099/1177, 6-25=-2099/1177, 7-25=-2175/1157, 7-8=-3099/1524, 8-9=-3184/1508, 9-26=-3444/1642,10-26=-3488/1622 BOT CHORD 2-16=-1376/3179,16-27=-979/2485, 15-27=-979/2485, 14-15=-979/2485, 13-14=-997/2485, 13-28=-997/2485, 12-28=-997/2485,10-12=-1386/3179 WEBS 6-14=-618/1313, 7-14=-790/517, 7-12=-221/667, 9-12=-453/383, 5-14=-790/517, 5-16=-221/667, 3-16=-453/383 WEBS 6-14=-618/1313, 7-14=-790/517, 7-12=-221/667, 9-12=-453/383, 5-14=-790/517, 5-16=-221/667, 3-16=-453/383 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=150mph (3-second gust) Vasd=116mph; TCDL=5.Opsf; BCDL=5.Opsf; h=25ft; Cat. II; Exp C; End., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 20-0-0, Exterior(2) 20-0-0 to 23-0-0 zone;C-C for members and forces 8 MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Plates checked for a plus or minus 0 degree rotation about its center. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.Opsf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb) 2=490, 10=490. LOAD CASE(S) Standard tht rer Or lYl rrle.b71 loot fIRt6rS[llEnffEw TEN t01710egt01011S-01"rilruclilf la'hn rtAi pup p ndm dml un h,lm, ksp etr.glRO;dd1rMe I Itrlt4 I I hlxnt LenW ne rdn, Inntl tMd LNp,rj e0ldtarotpid,smMtWhblxl M dl. htlrnr kV lean.ps. Spf ug mdl b".O,InwTAlgnml.Our- d0.tdb L,tl"ln'hwW1r M en'P d 0—elnn I."..Ae 00,.* INN ftp mtgNq lAal a O wttmdR.1 Anthony T. Tombo Ill, P.E. I rntds!,Im, htgMxyhOtn,ptdYWttlOeP.m.40.ai,rnitdyexn6W/gGuryr,.0ettmnnoeQL6 d0,Yden'lryn4dlK1 lhr nNIh101d WlerdNlm 1.i Y Oiywtgt.o,nCMdYrt JtAwuny uLLnn a 80083 t x px, pndt mnrr n,o.eeloorrpa,,.eµe,amauycwprmfearen m.pip+uregrnduuntd.uud emmlr,omraaunrr,eann,av..In,k [,fi...rlm,ure+..s 4451St. Lucie Blvd. nrnoftaiqweip,n1 nfrmstgrwd rwg nn.wu.dge yerq.mghap.n.ealrr ssdud[.ergxmd:.eneae mi. Fort Pierce, FL 34946 Opliipht0101AAd6dlnsses•Anhayl.loehrlll,pf teprodadierofdisloroment,ionet luaisproliEeeleithenrhe.rineipermiuirohem Adleolhnus-Anthony 1.l mbs111,Ll. Job Truss Truss Type Qty Ply RYAN HOMES / SEAGATE V4 WRCSG4D9 A10 Hip Truss 2 1 A01$2837 Job Reference (optional) 00r r r uaaea, Fort Pierce, rL r,uffo, design ga rtruss.com Hun: 8.120 s Nov 12 2017 Font: 8.120 s Nov 12 2017 MiTek Industries, Inc. Mon Dec 11 11y35.22 2017 Page.1 ID:UumEBPzOXokuwJ2P5W ?E2TyuP1 h-JYv4zFkl5V6dbwOt90_oojWGf4MkUmiujDc4iiyA3Up06-1-3 12-7-7 18-10-8 21-1-8 27-9 33-10-13 40-0 0 41 0 0 6-1-3 6.6-3 6-31 2-3-0 63-1 6-6-3 6-1-3 3x4 = 3x6 = LOADING(psf) SPACING- 2-" TCLL 20.0 Plate Grip DOL 1.25 TCDL 10.0 Lumber DOL 1.25 BCLL 0.0 Rep Stress Incr YES BCDL 10.0 Code FBC2017/TP12014 LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP M 30 'Except' B2: 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied or 2-8-7 oc pudins. BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. WEBS 1 Row at midpt 5-16, 8-15 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 2 = 1660/0-8-0 (min.0-1-15) 11 = 1660/0-8-0 (min.0-1-15) Max Horz 2 = 147(LC 12) Max Uplift 2 = 482(LC 12) 11 = 482(LC 13) Max Grav 2 = 1660(LC 1) 11 = 1660(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-25=-3560/1731, 3-25=-3525/1746, 3-4=-3243/1589,4-5=-3104/1603, 5-26=-2278/1266, 6-26=-2195/1287, 6-7=-2037/1246, 7-27=-2195/1287, 8-27=-2278/1266, 8-9=-3104/1603, 9-10=-3243/1589, 10-28=-3525/1746, 11-28=-3560/1731 BOTCHORD 2-18=-1501/3253,18-29=-1162/2637, 29-30=-1162/2637,17-30=-1162/2637, 16-17=-1162/2637,15-16=-759/2037, 14-15=-1173/2637, 14-31=-1173/2637, 31-32=-1173/2637, 13-32=-1173/2637, 11-13=-1513/3253 5.00 12 Sx6 = 5x6 = 4x6 = 3x4 = 3x4 = 4x6 = 3x4 = 18-10-8 21-1$, 30-8-10 9-7-2 2-3-0 ' 9-7-2 CSI. DEFL. in (loc) I/deb Ud TC 0.65 Vert(LL) 0.3713-15 999 240 BC 0.95 Vert(CT) 0.7213-15 670 180 WB 0.36 Horz(CT) 0.15 11 n/a n/a Matrix -MS BOT CHORD 2-18=-1501/3253, 18-29=-1162/2637, 29-30=-1162/2637, 17-30=-1162/2637, 16-17=-1162/2637, 15-16=-759/2037, 14-15=-1173/2637, 14-31 =-1 173/2637, 31-32=-1173/2637, 13-32=-1173/2637, 11-13=-1513/3253 WEBS 3-18=-412/353,5-18=-135/601, 5-16=-828/543, 6-16=-298/618, 7-15=-298/618, 8-15=-828/543, 8-13=-135/601, 10-13=-412/353 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=150mph (3-second gust) Vasd=116mph; TCDL=5.Opsf; BCDL=5.Opsf; h=25ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) -1-0-0 to 2-M, Interior(1) 2-0-0 to 18-10-8, Exterior(2) 18-10-8 to 21-1-8, Interior(1) 25-4-7 to 41-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) Plates checked for a plus or minus 0 degree rotation about its center. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-" wide will fit between the bottom chord and any other members, with BCDL = 10.Opsf. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 2=482, 11=482. LOAD CASE(S) Standard Dead Load DeB. = 3/8 in nN 6 a 12 3x6 = 6 PLATES GRIP MT20 2441190 Weight: 203 lb FT = 0% 6q.MuengYs mY.h'sl txln9SS5rRu[1)09ll ltmifOF711C11(1117xrIGTIY;INCRt1:slR tor, lit hop l.oemder to.. ft.I— ,gh,.gtrw.noihlfhq l lrY4r I. hour Sim wbn Widow—WrrMil/.r1 rld,t v,lo,Iglhrtrh 611ihMNJ s,rirar hvp ltp,up,. Steyrerhpeeyh,We.l lODrr'em.avtrm an lrb,ut rgau7q rey.Wilry h, hr lisp sl 4,q,Ivu cgnnle sh M odyvow IN fY h,p.-Pees. waluommeL m" dn„l en lmlhrg l.ugxor„q.eum.aa0ne.e,o..i,mvr yarr htlaWgaxprt,.h, ixne Aht alto ut almhd la7al rr, .f iM1l 1, gp,dlh,Iwd Fndl e,darm, atria rrY}arq,..mw rYrzy lH 6dr,gruun Anthony T. Tombo Ill, P E ushxalhtlimeod( ., .lA.a, l.rl.etTMalte pms dl.Urt,ade, 4m Gmar® sthgMwtWlJ prr,W ll rod sxs m rd—ut. xpe, d,,Egae rnirnsYnlr.+.u, see z80083tip.er Inlrs I.,npmlan.laerole,a oat 4451 St. Lucie Blvd. no,nutm.try,ttr,agdq..malp,uln.11n,na Irlavdurtyrml,sere.uialwnp.,eleusM,atqu,ar.ss.estq rnmss,ra•nnaraatnml. Fort Pierce, FL 34946oppilh102016A•Itadhoists -Arlmmy1.Thalia Ill, p.E.teprda0iad0rom isleol,inulfry,Ispsaiihud.rt6cntm litWitspe,missinhAdtoolhoists•Anthony1.lambsill,H. Job Truss Truss Type Oty Ply HOMES / SEAGATE v4 A0182838 WRCSG4Dt9 A11 Hip Truss 2 1 RYAN Job Reference (optional) Al Roof Trusses, Fort Pierce, FL 34946, design@altruss.com Run: 8.120 s Nov 12 2017 Print: 8.120 s Nov 12 2017 MiTek Industries, Inc. Mon Dec 11 11:35,22 2017 Page 1 ID:UumEBPzQXokuwJ2P5W9E2TyuP1 h-JYv4zFkl5V6dbwOt9O_oojWDX4PjU16ujDcgiiyA3Up 1-0 0 9-8-8 16 10 8 23-1-8 30-3-8 40-0-0 4,1_-Os0 9-8-8 7-2-0 6-3-0 7-2-0 9-8-8 3x6 = 5 00 12 5x6 = Sx6 = 5 a 1 5x4 II 3x8 MT20HS=3x4 = LOADING(psf) SPACING- 2-M TCLL 20.0 Plate Grip DOL 1.25 TCDL 10.0 Lumber DOL 1.25 BCLL 0.0 ' Rep Stress Incr YES BCDL 10.0 Code FBC2017frP12014 LUMBER - TOP CHORD 2x4 SP No.2 'Except' T1: 2x4 SP M 30 BOT CHORD 2x4 SP M 30 WEBS 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 5-10-0 oc bracing. WEBS 1 Row at midpt 3-14, 8-13 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 2 = 1660/0-8-0 (min. 0-1-15) 9 = 1660/0-8-0 (min.0-1-15) Max Horz 2 = 133(LC 13) Max Uplift 2 = 465(LC 12) 9 = 465(LC 13) Max Grav 2 = 1660(LC 1) 9 = 1660(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-23=-3378/1680,3-23=-3288/1710, 3-4=-2500/1385, 4-24=-2432/1394, 5-24=-2400/1411, 5-25=-2225/1363, 25-26=-2225/1363, 6-26=-2225/1363, 6-27=-2400/1411,7-27=-2432/1394, 7-8=-2500/1385, 8-28=-3288/1710, 9-28=-3378/1680 BOT CHORD 2-16=-1424/3035,15-16=-1424/3035, 14-15=-1424/3035,13-14=-922/2225, 12-13=-1435/3035,11-12=-1435/3035, 9-11=-1435/3035 WEBS 3-16=0/382, 3-14=-1041/592, 16-10-8 7-2-0 CSI. TC 0.85 BC 0.76 WB 0.40 Matrix -MS 13 11 3x4 =3x8 MT20HS= 1 Sx4 II DEFL- in (loc) 1/defl Ud Vert(LL)-0.7011-13 >683 240 Vert(CT) -0.9011-13 >531 180 Horz(CT) 0.15 9 n/a n/a WEBS 3-16=0/382, 3-14=-1041/592, 5-14=-216/606, 6-13=-216/606, 8-13=- 1041/592, 8-11 =0/382 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=150mph (3-second gust) Vasd=116mph; TCDL=S.Opsf; BCDL=S.Opsf; h=25ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 16-10-8, Exterior(2) 16-10-8 to 274-7, Interior(1) 274-7 to 41-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) Plates checked for a plus or minus 0 degree rotation about its center. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-" wide will fit between the bottom chord and any other members, with BCDL = 10.Opsf. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb) 2=465, 9=465. LOAD CASE(S) Standard Dead Load Defl. = 5/16 in 3x6 = PLATES GRIP MT20 244/190 MT20HS 187/143 Weight: 182 lb FT = 0% ar,q MvM,.dll re•h.h'11100F IIISStSrS41(rj(le;LL(ffU1Sl(JIDIIIte1(RIOY(IY17;UnCn1NE11'Wa lerf, Yvr Mntlm dmlurnnmLnl ksp Yr.l([4, dIY 4]e1 Wen It L hhenlleow-, U.'sowr.iu d"n"TH,.j b liZt mid rat, pft seen eul te, eh TM ll.U. If lhni"hiineaOr. SPOM hpn;tlYt n Or IU I¢neett edrYl-t a lO lllstew V 1n.4.011t bno 1.udN RLl Inv.[ de hwed a do dl,aen t?H Nn(p s.*m hdsq.m> wra1 Anthony T. Tombo 111, P.E. 0lmshr l hdlq lr 6ltrlwriW dhl Atn.M O.an'rntraN oftr lhl svp•,ab,lmn the RLWGdhbd laSlaA all ed .ih dlhid. f„dthell nedhelm4.ri.0 en6yu•b mr,0 w dh,ul di 1,nersWlllt 380083 0.lafal hfp,dha: err, eanaf rdIn•hIOD lel6l,lmur ed rteaelrtYpaq(Igwld(deR Ib'aebe(i61!plh4ldh Adsr(A—d—dtit p,fp6u ml s1Yr4nyendtael eMnfLbons hap,IlnsAnye[gaa ofImr aalrwx, a'ns la-WltalYmt. ortSt. Lucie Blvd. mps.— Fort Pierce, FL 3a9a6 lppipht07016A-lfoalhours -Wirogl.lomhlIlLrl. tepnhoiaadtiislotonem,inall form, is ploiihite6 irhemthernnespermission hem bl tool bases-Anhoofl lemia111,FI Job Truss Truss Type Qty Ply RYAN HOMES / SEA ATE v4 WRCSG409 Al2 Hip Truss 2 1 A01$2839 Job Reference (optional) i Roor trusses, ron 1-lerce, FL 34946, design@aitruss.com Hun: 8.120 s Nov 12 2017 Print: 8.120 s Nov 12 2017 MiTek Industries, Inc. Mon Dec 11 11 35:23 2017 Pagel ID:UumEBPzQXokuwJ2P5W?E2TyuP1 h-nkTSAblwsoETC4b3i6V1 Lw3R7UjCDE12ytLNF9yA3Uo 1-0 7-3 13 15-0-0 20-" 25-0 0 32-8-3 40-0 0 1 7-3 13 783 5 0 0 5 0 0 74 3 7-3 13 I 5.00 12 5x6 = 3x4 = 3x6 = 11-4-5 11-4-5 LOADING(psf) SPACING- 2-M TCLL 20.0 Plate Grip DOL 1.25 TCDL 10.0 Lumber DOL 1.25 BCLL 0.0 ' Rep Stress Incr YES BCDL 10.0 Code FBC2017/TP12014 LUMBER - TOP CHORD 2x4 SP M 30 'Except' T3: 2x4 SP No.2 BOT CHORD 2x4 SP M 30 'Except' B2: 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied or 3-3-10 oc purlins. BOT CHORD Rigid ceiling directly applied or 5-8-5 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 2 = 1660/0-8-0 (min.0-1-15) 10 = 1660/0-8-0 (min.0-1-15) Max Horz 2 = 119(LC 16) Max Uplift 2 = 447(LC 12) 10 = 447(LC 13) Max Grav 2 = 1660(LC 1) 10 = 1660(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-23=-3479/1838,3-23=-3444/1860, 34=-3044/1603,4-24=-2961/1606, 5-24=-2943/1622, 5-25=-2568/1524, 6-25=-2568/1524,6-26=-2568/1524, 7-26=-2568/1524,7-27=-2943/1622, 8-27=-2961/1606, 8-9=-3044/1603, 9-28=-3444/1860,10-28=-3479/1838 BOT CHORD 2-16=-1599/3179,16-29=-1066/2392, 15-29=-1066/2392, 15-30=-1066/2392, 14-30=-1066/2392, 14-31=-1077/2392, 13-31=-1077/2392, 13-32=-1077/2392, 12-32=-1077/2392,10-12=-1610/3179 WEBS 3-16=-576/514, 5-16=-232/662, 1.5x4 II 5x6 = Dead Load Deft. = 3/8 in 74 4x6 = 3x8 — 4x6 = 3x4 = 3x6 = 28-7-11 CSI. DEFL. in (loc) I/defl L/d PLATES GRIP TC 0.67 Vert(LL) 0.31 16-19 999 240 MT20 244/190 BC 0.87 Vert(CT) 0.71,16-19 679 180 WB 0.31 Horz(CT) 0.15 10 n/a n/a Matrix -MS Weight: 194 lb FT = 0% WEBS 3-16=-576/514, 5-16=-232/662, 5-14=-147/448, 7-14=-147/448, 7-12=232/662, 9-12=-576/514, 6-14=316/253 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=150mph (3-second gust) Vasd=116mph; TCDL=5.Opsf; BCDL=5.Opsf; h=25ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 15-0-0, Exterior(2) 15-0-0 to 29-2-15, Interior(1) 29-2-15 to 41-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) Plates checked for a plus or minus 0 degree rotation about its center. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-" wide will fit between the bottom chord and any other members, with BCDL = 10.Opsf. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 2=447, 10=447. LOAD CASE(S) Standard o.y.nn n.t lrt r. Ilnornrssa;umriarulnuulrotancli(nlox;atn;Imecuo:urrrtilrNrryr..,daerrl.ntua,rear.yl¢odrw111.rrtrLhi m%m sre, u+n,wwr OdNnmti lw,. m, lr.a.ra„mrrwnrlsur.uarl,amps,Apr.s ett.p.,mw.elm,i.mo.y„Ior euugwngrrq.w+nMd(r+a Wr1,,,MaN mlro.hd r4t.lrmn,ra.W., mini Anthony T.Tombo111,PE dn,ddhI.,taathlligl,ring,YMd6A+n.MO.n',HavNrptahWligGevryr,piupnAdnLV dMhdlays{WrdMI. Mgpntl.IhID0.WM R dWlivi—d ylrl3Sw,q,.h,M*..WYrcq,roI.r se-d }d a 80083 k, INWAVp,d(ICIOIII nmo n. III toW. d rm po,dpddw,ArkNq(rgaaa ldr lfi d[Wpi'mb IA d 1111 m rd.n,lrpndpd—In]Islas LnspnNsnd W,.!b1— h.q., I,n, kip faro allaw urd,aru, .!.1AIsdu ldd lrrtafia grNwormylrdptnmdrtiOrlnakptfpwhl0idillapknpr,nl:u,Sry>t Fgn,n dar rly NtoJdaN b.ur nl,hN dittl 4451 L Blvd Fort Pierce, FFL 34946 Oppiph10?OltA•IReel bran-AnllagLbmbeIII, l.l. teprdoaiaaoltlilloronem,is.gfrailproYhildrirhemihrwrinapermitsinhim A•Ilaallnnn-Aa16.n}LbntoIII, }.l Job Truss Truss Type Oty Ply HOMES / SEAGATE v4 A0182840 WRCSG4D9 A13 Hip 1 1 RYAN r. Job Reference (optional) Al KOOT I russes, ron rierce, rL 34J410, eeSlgn(ga I1n155.00M 5x8 = mull. O.14v5 llvV +L Lv+I e'I-. v.+GV.—V .L—I ID.IhohHggcR51lhi7ZLgIIoUviKGArv-Fx. 1eg'Yode6eMaKgnEwA. F,GpO„Gvle8+.ceOu,5XsyaX.xeB+BeXv5',x. nt. 4 1A 2x4 II 5x8 = 5 9a A Dead Load Dell. = 3/8 in 19 10 17 16 " 12 11 10 1.5x4 II 4x6 = 3x4 = 5x6 = 3x6 3x6 1. Sx4 II = 6x8 = 7-8- 8 LOADING(psf) SPACING- 2-M CSI. DEFL. in (loc) I/dell Ud TCLL 20.0 Plate Grip DOL 1.25 TC 0.57 Vert(LL) 0.34 15 999 240 TCDL 10.0 Lumber DOL 1.25 BC 0.74 Vert(CT) 0.69 13-14 695 180 BCLL 0.0 ' Rep Stress Incr YES WB 0.95 Horz(CT) 0.23 8 n/a n/a BCDL 10.0 Code FBC2017/TPI2014 Matrix -MS LUMBER - TOP CHORD 2x4 SP M 30 BOT CHORD 2x4 SP M 30 'Except' 133: 2x4 SP No.3, 82: 2x4 SP No.2 WEBS 2x4 SP No.3 'Except' W8: 2x4 SP No.2 BRACING - TOP CHORD Structural wood sheathing directly applied or 3-1-9 oc purlins. BOT CHORD Rigid ceiling directly applied or 4-8-15 oc bracing. Except: 10-0- 0 oc bracing: 14-16 WEBS 1 Row at midpt 14-17 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 2 = 1668/0- 8-0 (min. 0-1-15) 8 = 1671/0- 8-0 (min.0-2-0) Max Horz 2 = 104(LC 13) Max Uplift 2 = 443(LC 8) 8 = 442(LC 9) Max Grav 2 = 1668(LC 1) 8 = 1671(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2- 26=-3518/ 1793, 3-26=-3445/1815, 3-27=-2902/ 1575, 4-27=-2877/1593, 4-28=-3953/ 2159, 5-28=-3953/2159, 5-29=-3986/ 2164,6-29=-3986/2164, 6-30=-3769/ 2005, 7-30=-3793/1986, 7-31=-3456/ 1809,8-31=-3529/1787 BOTCHORD 2-19=- 154313180, 18-19=-1543/3180, 17-18=-1543/ 3180,13-14=-1581/3478, 8-10=-1550/ 3190, 5-14=-482/413 WEBS 7-10=- 612/ 433, 3-17=-671/438, WEBS 7-10=- 612/ 433, 3-17=-671/438, 6-13=334/ 830,10-13=-1572/3236, 7-13=-44/ 446, 14-17=-1129/2498, 4-14=-783/ 1577, 6-14=-348/766, 3-19=0/ 269 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=150mph (3-second gust) Vasd=116mph; TCDL= 5.Opsf; BCDL=5.Opsf; h=25ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) -1-0-0 to 2-M, Interior(1) 2-0-0 to 13-0-0, Exterior(2) 13-0-0 to 31-2-15, Interior(1) 31-2-15 to 41-0-0 zone;C-C for members and forces 8 MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1. 60 3) Provide adequate drainage to prevent water ponding. 4) Plates checked for a plus or minus 0 degree rotation about its center. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6- 0 tall by 2-M wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except ( jt=lb) 2=443, 8=442. LOAD CASE(S) Standard PLATES GRIP MT20 244/190 Weight: 216 lb FT = 0% U.411—derM mle.Ill 'A 11006111311 Risks 1[oe7DC13(IS101rVIT; x11C1111MAr l e I.* lydp poem me dn nt1-Dr+p hmglT[Q d nh'hl l Tell, ql l tests+ SlM tt'n nt WIl An.m wr. 14 ND,y YlldrtmNil'O+AaYtull hlADah. ee htlrnthvp[tp elir,Sp.dghpr;n.tees, W,ptstmm efx diet+rttaltgwlgnywWtlqh.ainot gte+ythenlyml•m11Dtl..6MI Ihhopea pne1d.1<lewle"eel" Anthony T. Tornbo 111, P.E. I dntANlmtln r 16g1+h+espwt rAhAm.hO. aierasDdy fudNtlyDn,pr,bitmeAotO(.itTdO+W/litgit4dlRl.lhgpindliDta80083 Y tx'lath+qmd(rta+.elo+M.6111dhptdttdphNt+dmW q(tq m wet etr m(tCJ!pWYtIH IIId YUmrdxnN'ptnep.lu lM1l A]nnnyylindlmetdnhmp+q44515t. Lucie Blvd. AtMuldnd lrefaet7ttl qtt+Rtq gtll l'.n Ydu111tlmt atrt[gmtbr01 tr1a1.y ksgo.n lm+ Src,Eepmroll.Llq M mMa el• .Imsd ml. Fort Pierce, FL 34946 eprti1At0101{Adbdluttet lutlarl.lem601,r.1. IepnbnleedltnAemaem,ieall him, itpr Ai1ue1 il{e/1lit vnneelermnmeehem Ad lead hates•A,Ihe,r1.feats Ill, L[. Job Truss Truss Type Qty Ply RYAN HOMES / SEAGATE V4 WRCSG4D9 A13H Hip 1 1 AOf82841 Job Reference (optional) Al Roof Trusses, Fort Fierce, FL 34946, design a@altruss.com Run: 8 120 s Nov 12 2017 Print: 8.120 s Nov 12 2017 MTek Industries, Inc. Mon Dec 11 11;35,252017 Page 1 ID: UumEB PzOXokuwJ 2P5W?E2Tyu P 1 h-j7bCbGmA000BSNkRgXXVOL8k61 RGh6SLPBgUJh yA3U m 1-0 7 0 1 13 0 0 20-0-0 27-0-0 32-11-15 40-0 0 1-0 7-0-1 5111-15 7-0 0 7-0 0 5-11-15 7-0-1 -0 3x4 = 3x6 = LOADING(psf) SPACING- 2-M TCLL 20.0 Plate Grip DOL 1.25 TCDL 10.0 Lumber DOL 1.25 BCLL 0.0 Rep Stress Incr YES BCDL 10.0 Code FBC2017/TP12014 LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP M 30 WEBS 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied. BOT CHORD Rigid ceiling directly applied or 5-8-11 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation quide. REACTIONS. (lb/size) 2 = 1660/0-8-0 (min.0-1-15) 8 = 1660/0-8-0 (min. 0-1-15) Max Horz 2 = 104(LC 12) Max Uplift 2 = 447(LC 8) 8 = 447(LC 9) Max Grav 2 = 1660(LC 1) 8 = 1660(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-21=-3495/1851, 3-21=-3451/1870, 3-22=-3192/1706, 4-22=-3113/1727, 4-23=-3006/1729, 5-23=-3006/1729, 5-24=-3006/1729, 6-24=-3006/1729, 6-25=-3113/1727, 7-25=-3192/1706, 7-26=-3451/1870,8-26=-3495/1851 BOT CHORD 2-14=-1606/3186,14-27=-119612577, 27-28=-1196/2577, 13-28=-1196/2577, 12-13=-1196/2577, 11-12=-1208/2577, 11-29=-1208/2577, 29-30=-1208/2577, 10-30=-1208/2577,8-10=-1618/3186 WEBS 3-14=-437/416, 4-14=-224/622, 4-12=-277/692, 5-12=-481/407, 6-12=-277/692,6-10=-224/622, 7-10=-437/416 Sx6 = 1.5x4 11 5x6 = 12 rr ca av ry 4x6 = 3x8 = 4x6 = 3x4 = 20.0-0 30-1-0 10-1-0 10-1-0 CSI. DEFL. in (loc) I/deft Ud TC 0.89 Vert(LL) 0.32 12-14 999 240 BC 0.71 Vert(CT) 0.6510-12 741 180 WB 0.42 Horz(CT) 0.15 8 n/a n/a Matrix -MS NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=150mph (3-second gust) Vasd=116mph; TCDL=5.Opsf; BCDL=5.Opsf; h=25ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 13-0-0, Exterior(2) 13-0-0 to 31-2-15, Interior(1) 31-2-15 to 41-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) Plates checked for a plus or minus 0 degree rotation about its center. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.Opsf. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 2=447, 8=447. LOAD CASE(S) Standard Dead Load Dell. = 5116 in 3x6 = PLATES GRIP MT20 244/190 Weight: 189 lb FT = 0% Wcdq•llnnd.r.dhrr rm'AIn01ilFMrfNlnGl1ilrlltlr.I11RLRfLh1mlheW,., W,ar..uwN.mmo,so YII. Yummipa,WlY.ulhhi7lbwr.E1I,ILn1161plglYtt111, 11UfJ([./.(..J,budNg100.gn.momles.dbKdnd..d.q.eslq ny vllq Erbhtpdo.,r/.Irn, L uNr.610D , NxIKI hhup,ssmpaLlmqu""UL,.NNR Anthony T. Tombo 111, P.E dn.ra,lm,hryl.,Uigl,o.mrwutdmdhA.n.MO.vi,.rbNd.vrYl.tlig0uipr,r,b,wort.lo,Itl,a,6:d46dlrf M,rflFl 1.q>,nd lYlWdnhelln.dhlmLdyglaCi}nh,Mrh..dku.9s OMorny Uwj!d r80083 APnsum. nI,r,02,han(uNmS/Mis"O. 1Jr4NN411.9sllmrd—cf.p-die MiMost 4n,rni/bi'mio i%!Is1 ,O.up,ln otvEq—odI.,rnrna.alm M.ry Nod ll.(a d q.N gr.•meglSAlrn ndni a.In„hu[qun,al01 C. 17'J>)Mup,n In„Sre.a Egwn dr.(Wq IO wiraNYnnn NiloRIl 4451 St. Lucie Blvd. OP1,i1h107D1dA•1[ oil lnssn4og AuLLmblIll, l.E. teprolodioulthis ihonem,inglnh,iSproh6ud BhenlEernrtopermm is,ixhbltaollnne,-IrlArerl.ImbIII,LE. Fort Pierce, FL34946 Job Truss Truss Type City Ply HOMES / SEAGATE v4 A0182842 WRCSG4Q9 A14D Hip 1 1 RYAN dr Job Reference (optional) Al Roof Trusses, Fort Pierce, FL 34946, design@altruss.com Sx10 = Run, 8.120 s Nov 12 2017 Print: 8.120 s Nov 12 2017 MiTek Industries, Inc. Mon Dec 11 11:35,26 2017 2x4 II 3x6 = S 3x8 = x6 = Dead Load Dell. = 9/16 in 23 " 21 1714 13 12 3x6 = 3x6 = 2x4 II 6x6 = 3x6 = 4x8 = LOADING (psf) SPACING- 2-M TCLL 20.0 Plate Grip DOL 1.25 TCDL 10.0 Lumber DOL 1.25 BCLL 0.0 Rep Stress Incr YES BCDL 10.0 Code FBC2017/TPI2014 LUMBER - TOP CHORD 2x4 SP No.2 'Except' T3: 2x4 SP M 30, T2: 2x4 SP M 31 BOT CHORD 2x4 SP No.2 'Except' B1,B4: 2x4 SP M 30, 133: 2x4 SP No.3 WEBS 2x4 SP No.3 'Except' W9,W4: 2x4 SP No.2 BRACING - TOP CHORD Structural wood sheathing directly applied. Except: 3-3-0 oc bracing: 7-8 BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. Except, 10-0-0 oc bracing: 19-21 WEBS 1 Row at midpt 19-23, 4-19 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 2 = 1689/0-8-0 (min.0-2-0) 10 = 1691/0-8-0 (min.0-2-0) Max Horz 2 = 89(LC 12) Max Uplift 2 = 458(LC 8) 10 = 457(LC 9) Max Grav 2 = 1689(LC 1) 10 = 1691(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (Ib) or less except when shown. TOP CHORD 2-31=-3538/1773, 3-31=-3496/1794, 3-32=-3177/1593,4-32=-3087/1608, 4-33=-5001/2482, 5-33=-5001/2482, 5-6=-5001/2482, 6-7=-5027/2480, 7-34=4038/2059, 8-34=4038/2059, 8-35=4218/2111, 9-35=4277/2096, 9-36=-3569/1773, 10-36=-3634/1755 BOT CHORD 2-23=-1521/3227,18-19=-2139/4890, 16-18=-2139/4890, 15.16=-2139/4890, 10-12=-1527/3294, 6-19=-408/349 29-0-0 CSI. DEFL. in loc) I/defl Ud TC 0.91 Vert(LL) 0.54 20 896 240 BC 0.97 Vert(CT) 1.04 20 462 180 WB 0.90 Horz(CT) 0.31 10 We n/a Matrix -MS BOT CHORD 2-23=-1521/3227,18-19=-2139/4890, 16-18=-2139/4890,15-16=-2139/4890, 10-12=-1527/3294,6-19=408/349 WEBS 9-12=-809/475, 3-23=-420/359, 8-15=-572/1385,12-15=-1566/3361, 9-15=-186/755, 19-23=-1166/2779, 4-19=-1083/2335,7-19=-73/276, 7-15=-1122/500,7-18=0/255 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=150mph (3-second gust) Vasd=116mph; TCDL=5.Opsf; BCDL=5 Opsf; h=25ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) -1-0-0 to 2-", Interior(1) 2-0-0 to 11-0-0, Exterior(2) 11-0-0 to 32-0-0, Interior(1) 32-" to 41-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate gnp DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are 1.5x4 MT20 unless otherwise indicated. 5) Plates checked for a plus or minus 0 degree rotation about its center. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb) 2=458, 10=457. 9) Graphical pur in representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. LOAD CASE(S) Standard PLATES GRIP MT20 244/190 Weight: 229 lb FT = 0% 4r1a1 My Mwpllr n+•a h'1111L1 nlssls ('Yuen fifJll ffu6 A f7r 11ICA fIS1dYj tT7; ltOCREKRR 6ia le-Ir y pntlm d id ohr wnt hnr Gegi nq (IN!wi r eEl I I Ir.f. q I l trhne Led Mn nr Cdoe dlnnv viol w N IOl.aj mid rrwmrrY,f tlfl.u1Wrn7h M,W1 lr rlydrlmpfpw.pr.Spdrhpe rWw r l0liyoemom doi prnu d gveml nywulilrykplwpdrre InulgeRluhlDD wl}. w6IRI lY lwp drngba.hLLq wnwt uadRr Anthony T. Tofnbo Ili, P E. IrudlM1lm Wglal/nllrhnipuYWdoeena.he.rirdasiiM.IdrNNgAuip,•teiwhndradL6R'IM6d1.Js1 Mi IfM1I lh(rnddhfWd!Oetlnrdhlm d l IYArn,YddlewrkagJ Mrmr uHnd v80083 r laLar ldpe wl leeroa Vuswedarit0 1r us f}ddmrdr M41(graa 4drp lA-aNji0lJ rlhflelhtndYU wrrdar rpmdrdsu lRl fmrn,edelan 1 Kydrhnrhgr,i:nshn.p [apa ernu Oa•had•, w'nr 4451 St. Lucie Blvd. nude ldlnlln (cored Ord qu•Ih nnn lwdrt! mfnuhut[pmueetr ld'Jay ptyr,nrmslyfia hN•rd r erl mr sfad Y.nndldadntnl Fort Pierce. FL 34946 bppiphr0}OIdAIAdLunn-Amlagl lemhelll,l1. tepndemianofibis duomem,inuyfilm, itpidiMed.ilEenthevrideepermissionhim A -I fool buses-Acheny1.bmhoill,p.l. v4 A0182843 1 4D9 A14H Hip a1Wss.cAm Run:8.120s Nov: u 2017Print: ku s Fort Pierce, FL 34946, design@ ID:UumEBPzOXZ9-0-0 Roof Trusses, nn-A-n tin 5x8 = 5x8 = 6x8 = 6 5x6 W8= 3x6 = 30 = SPACING- 2-" LOADING psf) te Grip 1.25 TCLL 20.0 Lumber DO LLumber 1.25 TCDL 10.0 Rep Stress Incr YES BCLL 0.0 Code FBC2017rrP12014 BCDL 10.0 LUMBER - TOP CHORD 2x 2* Except* x4 SP M 3 BOT CHORD 2 2 2 4 SP No2CePt' WEBS 20 SP No.3 OTHERS 20 SP No.3 BRACING - TOP CHORDStructuralwood sheathing directly applied. BOT CHORD lied or 5-0-15 oc bracing. Rigid ceiling directly app MiTek recommends that Stabiliz eruss erems ndrsand cuon,an cross bracing be installed duringaccordancewithStabilizerInstallation guide. REACTIONS. lb/size) 1660/0-8-0 (min.0-1-15) 2 1660/0-8-0 (min.0-1-15) 8 = Max Horz 89(LC 17) 2 = Max Uplift 473(LC 8) 2 - 473(LC 9) 8 = Max Grav 1660(LC 1) 2 1660(LC 1) 8 = 5x6 WB= J Iocin ( ) I/defl Lid CSI. DEFL. Vert(LL) 0.31 12 999 240 160TC0.90 0.89 Vert(CT) 0.7110-20 8 675 n/a n/aBC WB 0.98 Horz(CT) 0.17 Matrix -MS NOTES- 1) Unbalanced roof live loads have been considered for this design. rid ust 2) Wind: ASCE 7-10; Vult=150mph (3-seco 9 Vasd=116mph; TCDL=5.0psf; BCDL=S.Opsf; h=25ft; Cat. 11; Exp C; End., GCO O o•ZA-0Wn1eor(1) 2-0 0 to S (envelope) and - , Ex Exterior(2) 11 0-0 to 33-3-12, Interior(1) 11- 3-1 to41- r(2) forces & MWFRS for reactions shown; Lumber DOLzone;C-C for members 1 60 plate grip DOL=1.60 prevent water3) Provide adequate drainage to ponding. plus or minus 0 degree4) Plates checked for a p rotation about its center. .0 psf bottom5) This truss has been designed for a 10chordliveloadnonconcurrentwithanyother live loads. 6) ' This truss has been designed for a live load o20.0psf on the bottom chord in all areas where arectangle3-6-0 tall by 2-00 wide will fit between the bottom chord and any other members. 7) provide mechanical connection (by others) of truss to bearing plaatete capableable of withstanding 100 lb uplift ata joint(s) except (jt=lb) 2=473, 8=473. FORCES. (lb) Max. Comp.IMax. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD2-21=-346411881,3 21=-3422/1902, 3-4=-3102/16964-22=-3580/2034, 5-22=-3580/20 2034, 6-23=-3580/2034, 6-7=-310201696, 7-24=-3422/1902,8-24=-3464/1881 BOT CHORD2-14=-1633/3159,13-14=-1308/2825, 12-13=-1308/2825, 11-12=-131912825, 10-11=-1319/2825,8-10=-164413159 WEBS 3-14=-414/389, 4-14=-116/540, 6-10=-116/540,7-10=-414/389, 4-12=-519/988, 5-12=-6301534, 6-12=-519/988 LOAD CASE(S) Standard Dead Load Dell. = 318 in PLATES GRIP MT20 244/190 Weight: 190 lb FT = 0'1° IrddhlAril l,ar 4lL la,rn, ll,a Mre u, Can, Auf aay twti nlm dssd dnrn,lm, Me4 a.wl ,brit hoa,InMlOD rlf. du Rl Ir lnP r,.Mr+ ' a w rn,nr r,p 3 nwevll4 M n os} d inrui rdl r n mlr+n+l annan'IIr7GI nRs6tsn33rl aru3irnu uaantnrmomY runad+o.wP a+nm dr!i.0 rnami,,.rr6a M'•I r1i10br'+r Lue1.iL uN!r i ir,Sindry lr}r oe,rnnanllL*, It:d6,6AlaYgid,dlF1 it P' la„r10m„rLlln, Mara. YILSnwfniSn"Mr,dlubi7Dnr•r1. I,e0n, Marti Yk'4q MuP'.• ITd W.imrhedyroaFm.iryl Y'n,a,mrd3 rl ruab,Im,h,q WL I,h inpaMla!!dp"'a.60•rr,dr'a u„ I,sNaN Sdul rh•amr3tryi r a'Ih trl a 44 mo,alaMam nnl,Meldilil d laaa3 h,p d[w:un. lr ra,meuadlGDdhrrne, r3 Ni1oi I, ICinll7q Mape,ulnss 31taa 3apuu Aualu Wd ll a I.t 4d 9r o.nrl M NM1^ ninL irinu du} 1}rIppipNOlDl6klbdhotsuIwlYalyLlaabllll.rf.bp,odediaadtlblomnelt.°Ir11°a'tp'olilitelwilleN16erunelpe,mistinhanA•Iloo11n1urAl16wrl.laeloill,r.. Anthony T. Tombo Boo83 111, P E 4451 St. Lucie Blvd. Fort Pierce. FL 34946 Job Truss Truss Type Oty Ply RYAN HOMES / SEAGATE v4 A0182844 WRCSG4Da A15D Hip 1 1 1 Job Reference (optional) At Roof Trusses, Fort Pierce, FL 34946, design@altruss.com Run- 8.120 s Nov 12 2017 Print: 8.120 s Nov 12 2017 MiTek Industries, Inc. Mon Dec 11 11:35:28 2017 Page 1 ID:IhohHggcR5jfhi7ZLg11oUyiKGA-7iHLElp3hLsmJrTOVf5C2 mGhVQ7uN6n5938wMyA3Uj 6 9 2 9 0 0 1,2-2 20 6 0 25-9-14 2 -0 31-0-0 35-0 14 40 0 41-0 6-9-2 2-2-14 6 2-2 53 14 5 3 14 2 4 10-0 4 6 14 4-5 2 3x6 = 27 — 25 4x8 = 3x6 = 3x4 = 2x4 II 2x4 II 22 21 5x6 = 2x4 11 5x6 = 18 15 14 1.5x4 II 1.5x4 II 1.5x4 II LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/dell Ud TCLL 20.0 Plate Grip DOL 1.25 TC 0.81 Vert(LL) 0.64 22-25 748 240 TCDL 10.0 Lumber DOL 1.25 BC 0.89 Vert(CT) 1.18 22-25 407 180 BCLL 0.0 ' Rep Stress Incr YES WB 0.81 Horz(CT) 0.41 11 n/a n/a BCDL 10.0 Code FBC2017/TPI2014 Matrix -MS LUMBER - TOP CHORD 2x4 SP No.2 'Except' T3,T2: 2x6 SP 2400F 2.0E BOT CHORD 2x4 SP No.2 'Except' B1: 2x4 SP M 30, B4: 2x4 SP M 31 B3: 2x4 SP No.3 WEBS 2x4 SP No.3 *Except* W9,W11,W4,W3: 2x4 SP No.2 BRACING - TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins. Except: 3-10-0 oc bracing: 7-8 4-8-0 oc bracing: 8-9 BOT CHORD Rigid ceiling directly applied or 4-74 oc bracing. Except: 4-7-0 oc bracing: 20-23, 17-19 WEBS 1 Row at midpt 4-24, 8-16 JOINTS 1 Brace at Jt(s): 8 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 2 = 167910-8-0 (min. 0-2-0) 11 = 1687/0-8-0 (min. 0-2-0) Max Horz 2 = 74(LC 12) Max Uplift 2 = 489(LC 8) 11 = 485(LC 9) Max Grav 2 = 1679(LC 1) 11 = 1687(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-37=-3549/1809, 37-38=-3502/1815, 3-38=-3438/1827, 34=-3328/1743, 4-39=-6338/3186,5-39=-6340/3186, 5-6=-6900/3409, 6-7=-6900/3409, 7-8=-6900/3409, 8-40=-4678/2388, 9-40=-4676/2389, 9-41=4999/2491, TOP CHORD 2-37=-3549/1809, 37-38=-3502/1815, 3-38=-3438/1827, 3-4=-3328/1743, 4-39=-6338/3186,5-39=-6340/3186, 5-6=-6900/3409, 6-7=-6900/3409, 7-8=-6900/3409, 8-40=-4678/2388, 9-40=-4676/2389, 9-41=-4999/2491, 10-41=-5051/2480, 10-42=-3710/1870, 11-42=-3751/1860 BOT CHORD 2-27=-1552/3232, 26-27=-138/293, 25-26=-138/293, 23-24=-2973/6435, 20-23=-2973/6435, 19-20=-2868/6256, 17-19=-2868/6256, 16-17=-2868/6256, 11-13=-1649/3425,5-24=-627/422 WEBS 10-13=-893/517, 4-27=-310/133, 3-27=-316/303, 9-16=-703/1664, 13-16=-1665/3439,10-16=-465/1258, 24-27=-124512801,4-24=-1721/3556, 5-20=-207/599, 8-20=-343/792, 7-20=-358/272, 8-16=-1843/865 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=150mph (3-second gust) Vasd=116mph; TCDL=5.Opsf; BCDL=5.Opsf; h=25ft; Cat. II; Exp C; End., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) -1-0-0 to 2-0-0. Interior(1) 2-0-0 to 9-0-0, Exterior(2) 9-M to 34-0-0, Interior(1) 34-0-0 to 41-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) Plates checked for a plus or minus 0 degree rotation about its center. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. Dead Load Defl. = 5/8 in l 3x4 10 42 2 0 1 g1 1-2 13 6x6 = 3x6 = PLATES GRIP MT20 244/190 MT20HS 187/143 Weight: 262 lb FT = 0% 7) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-M wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=1b) 2=489, 11=485. 9) Graphical puriin representation does not depict the size or the orientation of the puriin along the top and/or bottom chord. LOAD CASE(S) Standard tu. hs•MvM,rtlh rrh.nr'lln0f n3SSn(Snitrj QltllI RUISIffipllCR nslhrj lGl7;uuCflfl:rl(P ra sent o#pmLndrt/etet.t>rslrm lrs'pom l:dr4llwrl IwhRtt. hlrm SlM Mxr.s m+merrnu wrwrlu.ry tddmmtr,retw.d h,rlWnw.tl l,rhns kMp [.p,r (1 r. Sr.nmr tr/-s,+,bud--rlW-rmem-rtvre.drKdsstdr,pw q nywulryror lwpdr s.yr lt., LrymlwrlAD Wr.wh Ttil llttmis—apsw.lwrgrson s.-dttl Anthony T. Tornbo 111, P.E. d.-d-Imsh,.7kenthr,-psrtrdra.m.r0.-f„d.vd.red.rWenlh.p•,.rmMalt- in. i.snWas hnd Y.{r.lydnN 1,appwddr Wdmhdlw,drlms.d,dqh -A-Frngr.-rtft-dM.nsJtwtwntpWlnd a80083 raayw,;,- doe.r 4451 St. Lucie Blvd. m.art-n.rsWd xtundp rrdruagoy.msedtasw.payh,u.rttitndsulmrd-.a.pdp e Intrs.ro,.t.aAu„dw eLuwro. ..lt.,r ps4.-drmrnrra.,wnr Armuldn. 11l.f r4 grd.p..rm.t li rOrnn Y,t.i rot.uhsrpltyw. isenr W.1lrup v,n1 ufra. 6pa f-r MDR m,A3tnM rtn .-tad Ynll Fort Pierce, FL 34946 opp lht 0 7016 A I lost bosses- AsAosy I. Tombs 111,7.1. lepudrmifuf this simmers, if e7lwm, is ptohihiied .idea the nine permission has A-f loof lrrsxs - Anthony l lmlo 111,1`1 Job Truss Truss Type Oty, Ply RYAN HOMES / SEAGATE v4 WRCSG4D9 A15H Hip 1 1 A01$2845 Job Reference (optional) 1 mu0j 1 ruses, rdrs rlerce, rc 34946, design@aiiruss.com Run: 8.120 s Nov 12 2017 Print: 8.120 s Nov 12 2017 MiTek Industries, Inc. Mon Dec 11 11;35:29 2017 Page,1 ID:UumEBPzOXokuwJ2P5W?E2TyuP1 h-bugjRephRe_dw?2D3McRaBJOKvmAdvEwKpoiSoyA3U 1-0 9-" 1fi 5-13 23-6-3 31-0-0 40-0-0 1 0 9-0-0 7-513 7-0-7 7-513 9-0-0 Dead Load Detl. = 3/8 in 5x6 = 3x4 = 4x6 = 3x4 = 5x6 = 5.00 12 3 91 e a c e 7 14 13 12 11 10 3x6 = 3x4 = 5x10 MT20HS= 3x4 = 5x10 MT20HS= 3x4 = 3x6 = Ste; LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.88 Vert(LL) 0.37 12 999 240 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.84 Vert(CT) 0.74 12-14 651 180 MT20HS 187/143 BCLL 00 ' Rep Stress Incr YES WB 0.50 Horz(CT) 0.19 8 Was n/a BCDL 10.0 Code FBC2017/TPI2014 Matrix -MS Weight: 174 lb FT = 0% LUMBER - TOP CHORD 2x4 SP M 31 *Except* T2,T3: 2x4 SP M 30 BOT CHORD 2x4 SP M 30 WEBS 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied. BOT CHORD Rigid ceiling directly applied or 5-0-0 oc bracing. WEBS 1 Row at midpt 4-14, 6-10 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 2 = 1660/0-8-0 (min.0-1-15) 8 = 1660/0-8-0 (min.0-1-15) Max Horz 2 = 74(LC 13) Max Uplift 2 = 498(LC 8) 8 = 498(LC 9) Max Grav 2 = 1660(LC 1) 8 = 1660(LC 1) FORCES. (Ib) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-21=-3392/1747, 21-22=-3300/1758, 3-22=-3297/1774, 3-23=-3075/1755, 4-23=-3075/1755, 4-5=-4216/2254, 5-6=-4216/2254, 6-24=-3075/1755, 7-24=-3075/1755,7-25=-3297/1774, 25-26=-3300/1758,8-26=-3392/1747 BOT CHORD 2-14=-1472/3044,13-14=-2051/4122, 12-13=-2051/4122, 11-12=-2053/4122, 10-1 1=-2053/4122, 8-10=-1483/3044 WEBS 3-14=-262/821, 4-14=-1313/705, 4-12=0/298,6-12=0/298,6-10=-1313l705, 7-10=-262/821 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=150mph (3-second gust) Vasd=116mph; TCDL=5.Opsf; BCDL=5.Opsf; h=25ft; Cat. II; Exp C; End., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) -1-0-0 to 2-M, Interior(1) 2-0-0 to 9-0-0, Exterior(2) 9-0-0 to 35-2-15, Interior(1) 35-2-15 to 41-" zone;C-C for members and forces 8 MWFRS for reactions shown; Lumber DOL=1.60 plate gnp DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise Indicated. 5) Plates checked for a plus or minus 0 degree rotation about its center. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) ' This truss has been designed for a live load of 20 Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-" wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb) 2=498, 8=498. LOAD CASE(S) Standard eedq•Ph. nnlgslI—.1le'A IIXf IdSS(SI-SUnid;tILRW 1(Oep11G1(IfI0xj 14L1-;L([eCR[K4AP Ars.rer/i YYr r.onm wm oln.mlint0ls lanyl(LQdW Le* I WaRlEhhm SimHrl nl UdnrdMnu ddY nlle lDl,wj YlhYrvMrrissA/IY.vlhbixlhM du,As•Irru kvplquw(le,f(e fghp.Y,hWu.(IDlrrrnenom dbr8lmmlq.eiq rty.Wtl>I tnb ln#del rajl(nuM'+hIn01 IN alIN h imp nuvpu.lwlar rlmin vae e',} Anthony T. Tombo 111, P.EIdeudWtmsbrl.ILglshngnuWnd.l0.n.40.risrAvdy dehl.ILgGuip•,.hinbndC11R.61R'dolYdl.YgidldlM1l ThIFF 1916W.AFhanldrdI.w ldgk oj.M'gl.hhdhndYrtq"Isto fruWlg0 a 80083 eadedlaLprnpidf.olnnN.nsnlwwhmowhprimr.(yddnldoldAlq(I.NmSed}hh.mnitNpe4lYrRldSidmrdnn tipme s.ARSII1ns4rnre.Wlxn IMsdLLnsAepn,lnsksp[afa.rnuwh.,a'ns 4451St. Lucie Blvd. Av.lu lhwlref.xv yeN qw. mtq lr elMr ndld rMlnu Nophian 111016 lilgelup.,n lnusro. Eq.n ear" IO rgCerll x:nnnlirl hip 1. Fort Pierce, FL 34946 oppilh107011Aliedhesses- Ankeny1.bmhe111.1.1. tepidenioelskisdemnem,inglmeLisprokikildwidenIlewrinespermissnebee AdIced irises-Asrhuy1.lemhoIII, Ll. w Job Truss Truss Type Oty Ply RYAN HOMES / SEAGATE v4 WRCSG4g9 A16D ROOF SPECIAL 1 2 A0182846 0 Job Reference (optional) Al rcoor I russes, r•ort merce, rL sq:wo, oesrgntaanruss.com 1-010 8-0-0 13t 5.00 12 5x6 = 3 35 o 34 1 2 23 3x6 = 3x4 = Run: 8.120 s Nov 12 2017 Print: 8.120 s Nov 12 2017 MiTek Industries, Inc. Mon Dec 11 11:35:30 2017 Page 1 5x6 = 2x4 11 1.5x4 = 14 zz 2x4 I I 2x4 11 5x6 _ N 5x8 — — 0 2x 5x8 11 N 6 8 9 36 37 a 39 8 1 Dead Load Dell. = 9116 in 40 11 6x 2 = 17 6x10 — 22 21 20 19 1.5x4 II 15 14 13 3x6 = 5x8 = 2x4 11 2x4 11 4x4 = 3x6 = 19-5-14 20-7 p 23-6-15 26 6 8 27 8 p 33-0-0 5-5-14 -1-1 2-11-7 2-11-9 -1 5-4-0 LOADING(psf) SPACING- 2-M CSI. DEFL. in loc) I/defl Ud TCLL 20.0 Plate Grip DOL 1.25 TIC 0.60 Vert(LL) 0.65 19 742 240 TCDL 10.0 Lumber DOL 1.25 BC 0.93 Vert(CT) 1.16 19 413 180 BCLL 0.0 ' Rep Stress Incr YES WB 0.99 Horz(CT) 0.30 11 n/a n/a BCDL 10.0 Code FBC2017/TPI2014 Matrix -MS LUMBER - TOP CHORD 2x4 SP No.2 'Except' T4,T6: 2x6 SP 2400F 2.0E BOT CHORD 2x4 SP No.2 'Except' B4: 2x4 SP M 30, B3: 2x4 SP No.3 WEBS 2x4 SP No.3'Except* W11: 2x4 SP No.2 BRACING - TOP CHORD Structural wood sheathing directly applied or 5-3-8 oc puriins. BOT CHORD Rigid ceiling directly applied or 7-4-4 oc bracing. Except: 2-2-0 oc bracing: 18-20 10-0-0 oc bracing: 14-16 JOINTS 1 Brace at Jt(s): 9, 8 REACTIONS. (lb/size) 2 = 1679/0-8-0 (min. 0-1-8) 11 = 1687/0-8-0 (min. 0-1-8) Max Horz 2 = -67(LC 13) Max Uplift 2 = -467(LC 9) 11 =-541(LC 13) Max Grav 2 = 1679(LC 1) 11 = 1687(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-34=-3494/1787, 34-35=-3411/1797, 3-35=-3393/1810,3-36=-3187/1775, 36-37=-3187/1775, 4-37=-3187/1775, 4-5=-5438/2866, 5-0=-9947/4983, 6-7=-10334/5154,7-8=-10334/5154, 8-9=-8868/4393, 9-38=-8518/4236, 10-38=-8517/4236, 10-39=-3528/1814, 39-40=-3537/1802, 11-40=-3606/1795 BOT CHORD 2-23=-1510/3147,22-23=-2030/4229, 21-22=-2030/4229, 20-21=-234/515, 17-18=-4700/9916,16-17=-4700/9916, 13-14=-164/380,11-13=-1552/3265, BOT CHORD 2-23=-1510/3147, 22-23=-2030/4229, 21-22=-2030/4229, 20-21=-234/515, 17-18=-4700/9916, 16-17=-4700/9916, 13-14=-164/380,11-13=-1552/3265, 6-18=-396/305, 9-16=-357/285 WEBS 3-23=-350/953, 4-23=-1379/663, 5-21=-3612/1870,5-18=-2491/5200, 13-16=-1449/2998,10-13=-5701381, 10-16=-2618/5459, 18-21=-2212/4575, 8-18=265/447, 8-16=-1120/562, 4-21=1315/2695 NOTES- 1) 2-ply truss to be connected together with 10d 0.131'x3') nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc, 2x6 - 2 rows staggered at 0-9-0 oc. Bottom chords connected as follows: 2x4 - 1 row at 0-9-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or B), unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-10; VuIt=150mph (3-second gust) Vasd=116mph; TCDL=5.Opsf; BCDL=5.Opsf; h=25ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 8-M, Exterior(2) 8-M to 14-M, Interior(1) 14-0-0 to 41-0-0 zone;C-C for members and forces 8 MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 5) Provide adequate drainage to prevent water ponding. 6) Plates checked for a plus or minus 0 degree rotation about its center. 7) This truss has been designed for a 10.0 psf bottom chord live load noreconcurrent with any other live loads. PLATES GRIP MT20 244/190 Weight: 492 lb FT = 0% 8) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-M wide will fit between the bottom chord and any other members. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except at --lb) 2=467, 11=541. 10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. LOAD CASE(S) Standard ebsgm.ee.w ymw.ell pnrsm slwrlar:wrtrxsewrana3ml tr(Imr;l[(1pRe:all trclulikd rorendmlunwtifOnikupYn IROdhlrJwrlls441lhi.—WoMnneTO, ins nldtwnMrllfl. OMweldhllhbM.eelereLrOelef¢.pe,SyoeOt[¢ ..urweglDDlptumwfe/teiaYrb dellwbingwvltlghMle lib5t 11n1lh.NMwOefaDrr,ee6ltil.M1hLpnU.pm.hwgrw..ee4uwlRy Anthony T.Tombo111,PE 80083 wlewbLrbwlNWelh6,wpee61me1tlAm.hO.wite,eLirdp.r6Mx:elhngwr,wpereeen uetll,Ae0.'d0ehdla aln4dllN Ih rnW 6lGdtnhttlnedWlmt.alyghfi}a,g6Y1n7brwlYttghY>aMYnyrttlln h pup Mlp,dhcx,. lOwnlaM dlhhdtY efe ul wlrJ eud6 pd41hgwm 4dtq MamwP6lJ htl,Ih I11 c1 U(I mrhnNY pnd pAae ml btn,nr.esemr.ewsrtiunso<s,..trnsres t.a<av as r,nr,+mw,,,u 4451 St. Lucie Blvd. eu. hwt"llotunm+q+•rhaerwiwend the hearWitw n.,wI—SrMywmdnr" aM*I wW.s s.lraidhDy. Fort Pierce, FL 34946 6pyrilht02016Adhnllnsses• Anthony1.limboIII,P.1 tepobaiauithsdoeonew,inaeyIwo,ispml3itdrithaatherrineyermissioohemAdPootlresses-A.rb.ayI.BntoIII,P.1. Job Truss Truss Type Qty Ply RYAN HOMES / SEAGATE v4 WRCSG4D9 A16H Hip Girder 1 1 A0182847 Job Reference (optional) Al Roof Trusses, Fort Pierce, FL 34946, design@altruss com Run, 8.120 s Nov 12 2017 Print: 8.120 s Nov 12 2017 MiTek Industries, Inc. Mon Dec 11 11435:31 2017 Page-1 ID.UumEBPzOXokuwJ2P5W9E2TyuP1 h-YHyTsKrxzGELAICbAnevgcOlbiXg5hHDo7HoAyA3Ug 1-0-0 7-0 0 14-2-11 21-7-1 28-8-0 33-0-0 40-0-0 41-0,p 1-0-0 7-0-0 7-2-11 7-4-6 7 0 15 -0 7-0-0 4x6 = 6x6 = LOADING (psf) SPACING- 2-M TCLL 20.0 Plate Grip DOL 1.25 TCDL 10.0 Lumber DOL 1.25 BCLL 0.0 ' Rep Stress Incr NO BCDL 10.0 Code FBC2017/TP12014 LUMBER - TOP CHORD 2x4 SP M 30 'Except' T2: 2x4 SP M 31 BOT CHORD 2x6 SP 2400F 2.0E WEBS 2x4 SP No.3 *Except* W2: 2x4 SP M 30 BRACING - TOP CHORD Structural wood sheathing directly applied. BOT CHORD Rigid ceiling directly applied or 5-7-8 oc bracing. WEBS 2 Rows at 1/3 pts 5-12 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 2 = 2016/0-8-0 (min.0-1-11) 12 = 4799/0-8-0 (min.0-4-0) 9 = 92/0-8-0 (min.0-1-8) Max Horz 2 = 59(LC 13) Max Uplift 2 = 818(LC 4) 12 = 2251(LC 4) 9 = 354(LC 24) Max Grav 2 = 2020(LC 19) 12 = 4799(LC 1) 9 = 137(LC 17) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-4658/1890, 3-21=-4294/1797, 21-22=-4294/1797, 22-23=-4294/1797, 4-23=-4294/1797,4-24=-4001/1309, 24-25=-4001/1309, 25-26=-4001/1309, 26-27=-4001/1309, 5-27=-4001/1309, 5-6=-1233/3020, 6-28=-1233/3020, 28-29=-1233/3020,7-29=-1233/3020, 7-30=-22/1144,8-30=-22/1144, 8-9=-62/1220 BOT CHORD 2-16=-1654/4239,16-31=-1904/4901, Dead Load Dell. = 5/16 in 406 = 6x10 = ' 4x6 = 6x8 = 6x6 = 5x8 = 4x6 = CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TC 0.96 Vert(LL) 0.2914-16 999 240 MT20 244/190 BC 0.52 Vert(CT) 0.5514-16 621 180 WB 0.91 Horz(CT) 0.08 12 n/a n/a Matrix -MS Weight: 211 lb FT = 0% BOT CHORD 2-16=-1654/4239,16-31=-1904/4901, 31-32=-1904/4901, 32-33=-1904/4901, 33-34=-1904/4901,15-34=-1904/4901, 15-35=-1904/4901, 14-35=-1904/4901, 14-36=-837/2356, 36-37=-837/2356, 37-38=-837/2356, 13-38=-837/2356, 13-39=-837/2356, 39-40=-837/2356, 12-40=-837/2356, 12•41=-3020/1358, 11-41=-3020/1358, 9-11=-1111/111 WEBS 3-16=-268/1088, 4-16=-751/256, 4-14=-1147/915, 5-14=443/2095, 5-12=-5775/2363, 7-12=-2065/1368, 7-1 1=-1553/2393, 8-1 1=-698/191 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=150mph (3-second gust) Vasd=116mph; TCDL=5.Opsf; BCDL=5.Opsf; h=25ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (envelope); porch right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) Plates checked for a plus or minus 0 degree rotation about its center. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads 6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except at=lb) 2=818, 12=2251, 9=354. 8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 222 lb down and 251 lb up at 7-0-0, 123 lb down and 139 lb up at 9-0-12, 123 lb down and 139 lb up at 11-0-12 123 lb down and 139 lb up at 13-0-12, 123 lb down and 139 lb up at 15-0-12, 123 lb down and 139 lb up at 17-0-12, 123 lb down and 139 lb up at 19-0-12, 123 lb down and 139 lb up at 20-11-4, 123 lb down and 139 lb up at 22-11-4. 123 lb down and 139 lb up at 24-11-4, 123 Ill down and 139 lb up at 26-11-4, 123 lb down and 139 lb up at 28-11-4, and 29 lb down and 53 lb up at 30-11-4, and 105 lb down and 165 lb up at 33-0-0 on top chord, and 399 lb down and 315 lb up at 7-M, 88 lb down at 9-0-12, 88 lb down at 11-0-12, 88 lb down at 13-0-12, 88 lb down at 15-0-12, 88 lb down at 17-0-12, 88 lb down at 19-0-12, 88 lb down at 20-11-4, 88 lb down at 22-11-4, 88 lb down at 24-11-4, 88 lb down at 26-11-4, and 192 lb down and 183 lb up at 30-11-4, and 520 lb down and 513 lb up at 32-11-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25 Plate Increase=1.25 Uniform Loads (plf) Vert: 1-3=-60, 3-8=-60, 8-10=-60, 2-9=-20 Concentrated Loads (lb) Vert: 3=- 1 75(F) 6=- 1 23(F) 8=-58(F) 16=-399(F) 7=-123(F) 11=-520(F)21=-123(F)22=-123(F) 23=-123(F)24=-123(F) 25=-123(F)26=-123(F) 27=-123(F) 28=-123(F) 29=-123(F)30=-6(F) 31 =-71 (F) 32=-71 (F) 33=-71 (F) 34=-71 (F) 35=-71 (F) 36=-71(F) 37=-71(F) 38=-71(F) 39=-71(F) 40=-71(F) 41=-192(F) odq Mu MgYI irk.hYIIJfiI arssa rSrllEl jQI'.LLI IIW1(Oipllig(glpxj tYf7';1(ntiltgl[RIN.hill rinip pwtm dml olnnhr Ln% lnpk"(TW, d rrhr I InaN4f I W—LMMnnr NlmdMnvddYnb Weeir YlllYtnwmtr'nflMM.u1MhIMglr,rfl hrlmtNslplgrapr.SlrudkhprM,mudunlpligrsmrorrupticrdmpdnYwdnlwagngnlAelbbinpiD.SrJehn54l dInM10Dw¢,dnfM1l M1lnpnngnitl.IdquunnliNYl1? Anthony T. Tombo 111, P.E I d.ud rlmlWgNufighmnqwdkkrdmAmme.i.non:dgdnmNdligNuryr,prmm dmutmxdmkdMlgn4dlFl iNgrndd0.TGdn.Namdmrm..dMgkrdYM1aigr.inbldandk,,gddikrrnF.'"urd s90083 h t Lq N.pcd(omn Nrar In ru tr NDdbl rd phlmrdm Nag lwlwmSdq Ml dln(I(LJrdh+4lh lHd Lll midrnw pmtlfdsu rnlnSrrbrry.w/an dYlnlL hm Nu l— drmrl'nittwu, n'm r2e.lu lduM ll l (ail qrd qr .mq lr dl lnn bdid. b lnu dui Ini— k lei Y ldq Nup, n lmr Sp+Iqum.1.1 Was; le gfllzd to n n liW k llll 4451PieSt.rce, F le Blvd. Fort Pierce, FL 34946 6ppiph107016Adilellnsus AtlYaorLhMEN lll,r[.teproluOuullYisloconem,ilullro,ispmli6iledriAlNlhlmienpermiunlhlol•Ihcllnua-Mthurl.Im6cIII,R. Job Truss Truss Type Qty Ply RYAN HOMES / SEAGATE v4 A0182848 WRCSG449 C01 Hip Girder 1 1 d Job Reference (optional) Al Roof Trusses, Fort Pierce, FL 34946, design@altruss.com Run: 8.120 s Nov 12 2017 Print: 8.120 s Nov 12 2017 MiTek Industries, Inc. Mon Dec 11 11:35:32 2017 Page 1 I D:IhohHggcR5jfhi7ZLg 1 IoUyiKGA-0TWs3gsZkZMCnSnokVABCgxwg6n7gHxNOn 1 M37yA3Uf 1-0-0 6-0-0 10-6-0 15-0-0 20-7-12 1-0 0 6-0-0 4-6-0 4-641 5-7-12 Dead Load Dell. = 3/8 in 5x6 = 5x10 MT20HS= 3x4 = 3x6 = 4x6 = LOADING (psf) SPACING- 2-M TCLL 20.0 Plate Grip DOL 1.25 TCDL 10.0 Lumber DOL 1.25 BCLL 0.0 Rep Stress Incr NO BCDL 10.0 Code FBC20171TPI2014 LUMBER - TOP CHORD 2x4 SP N0.2 BOT CHORD 2x4 SP M 31 'Except' B2: 2x4 SP M 30 WEBS 2x4 SP No.3 WEDGE Right: 2x4 SP N0.3 BRACING - TOP CHORD Structural wood sheathing directly applied. BOT CHORD Rigid ceiling directly applied or 5-10-13 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 6 = 1550/0-3-12 (min.0-1-13) 2 = 1571/0-8-0 (min. 0-1-8) Max Harz 2 = 65(LC 27) Max Uplift 6 = 617(LC 9) 2 = 616(LC 8) Max Grav 6 = 1550(LC 1) 2 = 1571(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-3443/1303, 3-16=-3169/1250, 16-17=-3169/1250,4-17=-3169/1250, 4-18=-3071/1249,18-19=-3071/1249, 5-19=-3071/1249, 5-0=-3354/1311 BOT CHORD 2-9=-1158/3115,9-20=-1526/3641, 20-21=-1526/3641, 21-22=-1526/3641, 8-22=-1526/3641,8-23=-1526/3641, 7-23=-1526/3641,6-7=-1151/3018 WEBS 3-9=-287/972, 4-9=-643/423, 4-7=-733/418, 5-7=-256/937 CSI. DEFL. in loc) I/deft L/d TC 0.93 Vert(LL) 0.28 7-9 889 240 BC 0.95 Vert(CT) 0.66 7-9 377 180 WB 0.37 Horz(CT) 0.09 6 n/a n/a Matrix -MS NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=150mph (3-second gust) Vasd=116mph; TCDL=5.Opsf; BCDL=5.Opsf; h=25ft; Cal. 11; Exp C; Encl., GCpi=0.18; MWFRS (envelope); Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) Plates checked for a plus or minus 0 degree rotation about its center. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrenl with any other live loads. 7) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 6=617, 2=616. 9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 95 lb down and 119 lb up at 7-0-12, 95 lb down and 119 lb up at 9-0-12, 95 Ib down and 119 lb up at 10-6-6, 95 Ib down and 119 Ib up at 11-11-4, and 95 lb down and 119 lb up at 13-11-4, and 67 lb down and 105 lb up at 15-0-0 on top chord, and 304 lb down and 218 lb up at 6-0-0, 69 lb down at 7-0-12, 69 lb down at 9-0-12, 69 Ib down at 10-6-6, 69 Ib down at 11-11-4, and 69 lb down at 13-114, and 304 lb down and 218 lb up at 15-0-0 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 10) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25 Plate Increase=1.25 Uniform Loads (plf) Vert: 1-3=-60, 3-5=-60, 5-6=-60, 10-13=-20 Concentrated Loads (lb) PLATES GRIP MT20 244/190 MT20HS 187/143 Weight: 87 lb FT = 0% Standard Vert: 5=-38(B) 8=-58(B) 9=-304(B) 4=-95(B) 7=-304(B) 16=-95(B) 17=-95(B) 18=-95(B) 19=-95(B) 20=-58(B) 21 =-58(B) 22=-58(B) 23=-58(B) q rb..er. nwd rirmn115ABruuu•larturam1013MISMIONI ¢tmuu[aEurrdabnr" Ktd-eirwnild-1 rnnb.aw.mmr,.y YII.Yr. amrrurltila sk, ir. rbegrrqurp i.Wdy(.w.rdelura q 111rgrbmr arv. AM FMWd",ftjnyauldgbrbr Mede. sipWrr heave f.T100.,id. Ml hbLp nugmn.btqum.t umlRl AnthonyT Tombo 111, P.E. a80083 Ylw' igMfpad( wr¢tN.>,rrMr6I0Dd6pmn.f rltlntdo. bdlq(q.m4hglMrpdJpWrWhnldUllnrdrmi'r pN la[M1l tlrrLrry.nitan.rYnf4linr Avry.lmrin#fgr.lfmrl+Ma*r,ant 4451 St. Lucie Blvd lr.lu bfbdlr.(.t.a -alga re d rrarb.drrine In duttq.b b 161 btWerik4w, nrn:tsrm3 peer any rllq 11mil.db:or.elt.dbrlllFort Pierce, FL 34946 GppiphrlDlDlhAliullnsser nhagl. l.mhlIII, LE. hprd.GialdAislrronem,iratINC, itprohiledriAetlthe ninelpermittiuhim Adlodh.un-Willey l.foots III, L[. Job Truss Truss Type Qty Ply RYAN HOMES / SEAGATE V4 WRCSG4D9 CJ1 Comer Jack 10 1 A0192849 Job Reference (optional) r.00 Fusses. run —erce, rL sv O, uesign(a a IU rrr nun. o. r cv b rvuv r z cu i r Prim: 6.1.1u s NOV iz zui r mi I ex Inaustnes, Inc. Mon Dec 11 11.,35:33 2017 Page-1 ID: UumEBPzQXokuwJ2P5W?E2TyuP 1 h-Ug4EH?sCVtU3PcM_IChNl1 THKW HzZpOWFRmvbrayA3Ue 1-0-0 0-111-11 1-0-0 0-1-11 2x4 LOADING(psf) SPACING- 2-M CSI. DEFL. in loc) I/defl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.17 Vert(LL) 0.00 5 999 240 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.21 Vert(CT) 0.00 5 999 180 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(CT) 0.00 3 n/a n/a BCDL 10.0 Code FBC20171TPI2014 Matrix -MP Weight: 5 lb FT = 0% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 BRACING - TOP CHORD Structural wood sheathing directly applied or 0-11-11 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 3 = 24/Mechanical 4 = 37/Mechanical 2 = 198/0-3-8 (min. 0-1-8) Max Horz 2 = 38(LC 8) Max Uplift 3 = 24(LC 1) 4 = 37(LC 1) 2 = 125(LC 8) Max Grav 3 = 25(LC 8) 4 = 37(LC 8) 2 = 198(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=150mph (3-second gust) Vasd=116mph; TCDL=5.Opsf; BCDL=5.Opsf; h=25ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (envelope) and C-C Comer(3) zone; porch left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Plates checked for a plus or minus 0 degree rotation about its center. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-" wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3, 4 except (jt=lb) 2=125. LOAD CASE(S) Standard r.,q.nnnn.04rruuln .r.•rlrnsam rillinanTIMA(anrnmT011r;lr[rolltKrERhmhrilYJrMndmd-Jinn hrlrnr*IV hnglfrCddoIA.,II hglLtdn.WwW-.eU.,M —vwdrmTN, q WlrYrrrrorrrn rM.nNM nr Inisk'N b.1..r hsrye hprr[n,1tr.Wrleper;Mrr rr r lOD nynnsravpararp6xurdgw:gngrW lqNnlnpdh se;fe liar RgnNn NND rll wla PFl. lh letpnuaprn lrrytaLawytrJrl I derdr ImrWgMLgh6rnphm dvr0'u 60.airnRCdglnhMUgOapr,.br hnrvellLde0.IOrlydlafalide AIM1I.IIrglrN/hfDldo Adlnrdnrrm tldgl 6}aigr,YmEerdYrugJ Ytyngood".1 Anthony 80083 Ili, P. E. h tala h, rt rr.-rn. U ril id ed a I* TM rnr .rd fie. M1 OW Mr 80083 a w p.nnadpYmsdmpulq(ryrW4drglrndu(f0 NnMhrltaUlemrdarNY nrerdeanrenndLlmhdra.nnroy[q.a rrmrr„d,n..r r ndauwdrgecu-nRrdquo„mgtrnrnn.' d d nrmdhur.rq.nrhrclorlrrarouy.,rrnds algnrnd rruq mmx dd runnardnnsr. 4451 St. Lucie Blvd. A iNOf01A#Ifedhassn- Aetlea Llem6eltl,ll. reralaaieedtiislomrem,iau Im Fort Pierce. FL 34946 Pnl l P 1 skisrraltihd.itbmtitvnnnrermissitshemAdleaflmses-Aetitarl.leertalll,Ll. Job Truss Truss Type Qb Ply RYAN HOMES / SEAGATE V4 A0182850 WRCSG4g9 CJ3 Comer Jack 7 1 Job Reference (optional) All Root Trusses, Fort Pierce, FL 3494b, des(gn(galtnlss.com Kun: a.izu s Nov (z zu 1 / rnnr. o. i4u b Nuv Iz zu, r —cm Cn 11—bui—I nib. 1-11 — 1 1 1 1. . U. r ID: UumEBPzQXokuwJ2P5W 9E2TyuP 1 h-ysecULlgGBcw1 mwAswCcH FORQwd71GGfU4 WSBOyA3Ud 1 0 0 2-11-11 1 0 0 2-11-11 3x4 = 2-11-11 2-11-11 LOADING (psf) SPACING- 2-" CSI. DEFL. in loc) I/defl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.21 Vert(LL) 0.02 4-7 999 240 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.22 Vert(CT) 0.02 4-7 999 180 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 3 n/a n/a BCDL 10.0 Code FBC2017/TPI2014 Matrix -MP Weight: 11 lb FT = 0% LUMBER - TOP CHORD 2x4 SP N0.2 BOT CHORD 2x4 SP No.2 BRACING - TOP CHORD Structural wood sheathing directly applied or 2-11-11 oc puriins. BOT CHORD Rigid ceiling directly applied or 10-M oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 3 = 70/Mechanical 2 = 187/0-8-0 (min.0-1-8) 4 = 36/Mechanical Max Horz 2 = 75(LC 12) Max Uplift 3 = 48(LC 12) 2 = 119(LC 8) 4 = 35(LC 9) Max Grav 3 = 70(LC 1) 2 = 187(LC 1) 4 = 51(LC 3) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=150mph (3-second gust) Vasd=116mph; TCDL=5.Opsf; BCDL=5.Opsf; h=25ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (envelope) and C-C Comer(3) -1-0-0 to 2-0-0, Exterior(2) 2-0-0 to 2-10-15 zone; porch left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Plates checked for a plus or minus 0 degree rotation about its center. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-M wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3, 4 except Qt=lb) 2=119. LOAD CASE(S) Standard rely MvO.MYt rrN.h'11 nOf 1ilffli'Mlln9r;1411MA(010111CISMO11j Wrr;4UCV11KKR SO.hrelY,ir pnnmdrrJ do ntl n, 7ngahr.q(wmilhlhl I. lull Cl lC tft.'%en Mnn, kilns Gr.m wMnAl To' rj nmu.mlri,mirnddo117DaMrrJlistrn,AeL lgx(II,SK aftsisswuYwqlODrgnm.ayundWMtnuldgxe llnlnUllghminVi4uiloNisbM.1blWO.aYTRllrtr pn,upwKgrmwuW41 Anthony T.TomboIII, P.E I d.u antm,'u Wlnlhtrrup,dale!rJtrAae.hO.an,o0tl:d¢arbinllnlhxryr,rrYlr.Lnr 414i,IirdalYdlrilsln4dlF1 ihq nJdnerndr.!WIn,dMfmtdl4lldlr tai 6o,nhmdkq,MhbnynuWd 280083 d O.Wgh,j.OMn C. W•a„ao.trihd At.Fidd isdrhn,S111O r(yn oulMtM'amr(tWllYnldhrfldSLLlnhnlf4pnnp ndinh. INift,6Nlandionf4tin,htgn,hniW*fq ndTins rvu, mi 4451 St. Lucie Blvd. 1mnu l dlfa(nnd4d go.rOgh p:n lmhel hlnu hOrtr/+InhtCitr Wghtry.,almtfnRa Erpn Eert M!>f NgOIaM:unnld dofill Fort Pierce, FL 34946 opplia 02011AIbdb.sso- Whirl l.lamhalll,p.1. ttpnlbosoul(hsArooem, ill Oil lorr,ispickiAutArithtatlit wine. peraissieharAd[oaf haues•Aathtoll.l.nhoIII, l.l. Job Truss Truss Type Oty Ply RYAN HOMES / SEAGATE V4 WRCSG4D9 CJ3A Comer Jack 1 1 A0182851 Job Reference (optional) wr „wa , u'iatow, -u or ar . it. In Run: 8.120 s Nov 12 2017 Print: 8.120 s Nov 12 2017 MiTek Industries, Inc. Mon Dec 11 11;35:35 2017 Page 1 ID.UumEBPzQXokuwJ2P5W?E2TyuP1 h-Q2C_ihuS1 UkmewVMPdjrgSZduK_3ljWpikFOg$yA3Uc 2-7-7 2-7-7 2x4 = 2-7-7 LOADING(psf) SPACING- 2-" CSI. DEFL. in loc) I/de0 Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.17 Vert(LL) 0.01 3-6 999 240 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.17 Vert(CT) 0.01 3-6 999 180 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(CT) 0.00 2 n/a n/a BCDL 10.0 Code FBC2017/TPI2014 Matrix -MP Weight: 8 lb FT = 0% LUMBER - TOP CHORD 2x4 SP No.2 SOT CHORD 2x4 SP No.2 BRACING - TOP CHORD Structural wood sheathing directly applied or 2-7-7 oc purlins. BOT CHORD Rigid ceiling directly applied or 104)-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 1 = 10210-3-12 (min. 0-1-8) 2 = 68/Mechanical 3 = 35/Mechanical Max Horz 1 = 51(LC 12) Max Uplift 1 = 22(LC 12) 2 = 49(LC 12) 3 = 1(LC 12) Max Grav 1 = 102(LC 1) 2 = 68(LC 1) 3 = 48(LC 3) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=150mph (3-second gust) Vasd=116mph; TCDL=5.Opsf; BCDL=S.Opsf; h=25ft; Cat. II; Exp C; End., GCpi=0.18; MWFRS (envelope) and C-C Comer(3) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Plates checked for a plus or minus 0 degree rotation about its center. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) a This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-M wde will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 2, 3. LOAD CASE(S) Standard mry.nnnn.,qy,Mn,l.•elfurnamruuEnar n«wsecoeanuimfDx;mr;llnCi![EWllli•feahrfrlrupfandrndrnlunwnrlimhnphuglff4ldrle ll.ietrGlfLldnarflmMrnr wurmn.uwdnmml,.ry ruulromrt ar unrret.ri»r.rt arirn,r.p lrp..(tr,sp.,af hpn,mww.,rm upevo,o.upardrpdnu.d npn,rey.wulroreropder la7r inss gmenmfho.ar. r. rFi nr pnnyero.irgemn>.uumT I dnrdkslmfhrglW,gBrrnprd4t.dea0.ur,rOnriresllNyzfnmlrr«nfhniprr,ameuhnd1a0t4{:rmbdeaY n4rIFl, i6gMnddrNOis!ydenrdhrim irldlglrh}mgr,mhCdwWit" lrrrupid"ed Anthony TOmt10111, P.E. 80083rr.dayrfpndfeere..lh.asNMarlhDdrp.ms pddmtdrrNq(ryrmWrpFA m.IRflJrl4JethfgdlLLlmrd.wehpmlplrat Mltl.trrryreiit9nrMerdriintrup.,hnfrtpG..rtrntteWi.,a'nr4451 St. Lucie Blvd. I"byI(". rol". mehatree.nnahI..NU,I*.rrnenrw.lnum,.,1— Sims bp.d Iwq mmid:,t:m rnrtmrin1. Aepyiphi0IDldAdbdhessts- Aothtay1.ltd# III, PLteprodoci000fthsdommem,itnyfore,isprohih4edsilliest the sn«etptimissitthot Adtoollnset-AttheoyllomtoIII, t.l. Fort Pierce, FL 34946 Job Truss Truss Type Qty Ply RYAN HOMES / SEAGATE v4 A0182852 WRCSG4D9 CJ5 Comer Jack 7 1 Job Reference (optional) At Roof Trusses, Fort Pierce, FL 34946, design@allruss.com Run: 8.120 s Nov 12 2017 Print: 8.120 s Nov 12 2017 MiTek Industries, Inc. Mon Dec 11 11:35:36 2017 Page 1 I D: UumEBPzQXokuwJ2P5WTE2TyuP 1 h-uEIMvl v400sdG44ZzLE4Mg5iMkESmAmyxOTZCuyA3Ub 1-0-0 4-11-11 1 0 0 4-11-11 2x4 = LOADING(psf) SPACING- 2-M CS1. DEFL. in loc) I/dell Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TIC 0.57 Vert(LL) 0.13 4-7 462 240 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.54 Vert(CT) 0.11 4-7 532 180 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(CT) 0.00 3 n/a n/a BCDL 10.0 Code FBC20171TPI2014 Matrix -MP Weight: 17 lb FT = 0% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 BRACING - TOP CHORD Structural wood sheathing directly applied or 4-11-11 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-" oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 3 = 126/Mechanical 2 = 263/0-8-0 (min. 0-1-8) 4 = 64/Mechanical Max Horz 2 = 115(LC 12) Max Uplift 3 = 89(LC 12) 2 = 157(LC 8) 4 = 61(LC 9) Max Grav 3 = 126(LC 1) 2 = 263(LC 1) 4 = 90(LC 3) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=150mph (3-second gust) Vasd=116mph; TCDL=5.Opsf; BCDL=5.Opsf; h=25ft; Cat. ll; Exp C; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) -1-0-0 to 2-M, Interior(1) 2-0-0 to 4-10-15 zone; porch left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Plates checked for a plus or minus 0 degree rotation about its center. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-M wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3, 4 except (jt=lb) 2=157. LOAD CASE(S) Standard f ryitblY S.'kh rr..hYI IM II S{6r0Lr1rtl.lxI11W{[ocantntmOxs-WT9';llC{C0.1WRhs. Ilrh kOppm ndnal mn h,Ln, G,prnq 'uhIrJrr I Irk0.t I b1—%WW ,Otn, r,.nr o dnOr IOl,ry ntauumrlra,rmkrultur.104kwAnthony T.Tombo111,PE I d,wdILIIrviiwin kulliIsOrinpl3d!dC.Nm.doQ—,WwUni psw0.Ir 1,9k p,,.Worst, lr,RLisCrlhb.1Whgn4dMy a 80083 h tuglnsmdL . m.„aM.atoodrrpu„drean,edkati W.m snrtm m.LwL[{ra,uhtndsul o rmrewk pa"p - tnl4451 St. Lucie Blvd r!dv Wuk l!aLaxa 4eb gr rreq l!ALu,nrlui frlm,G,er[ynrhlcl C.IrPI.I rup,rtlmssina[q,fri Mlrl N]i,lbmrnlld ml, Fort Pierce, FL 34946 AppijM07hldAllwlhntn Anlagll.mh. IL1.p.1. 11plododial W ibis looristro, in fly how, is inciMed willstor list written Fermissiom how A4 loaf hinses - Anthony 1. Inds III, P.I. 30 = SPACING- 2-0-0 LOADING psf) Plate Grip DOL 1.25 TCLL 20.0 Lumber DOL 1.25 TCDL BCLL 10.0 0.0 Rep Stress Incr YES FBC2017ITP12014 BCDL 10.0 Code LUMBER - TOP CHORD 2x4 SP No-2 BOT CHORD 2x4 SP No.2 BRACING- TOP CHORD or 4-7-7 ocStructuralwoodsheathingdirectlyapplied pudins. iggggff] lied or 10-0-0 oc bracing•ectly appairedends that StabiliziNss ereclon, inbeinstalledduringithStabilizerInstallationaide. REACTIONS. (lb/size0-3-12 (min. 0-1-8) 1 122/Mechanical 2 601Mechanic3l 3 Max Horz 92(LC 12) 1 Max Uplift 42(LC 12) 1 = 89(LC 12) 2 Max Grav 182(LC 1) 1 = 122(LC 1) 2 - 85(LC 3) 4- 7-7 4- 7-7 in loc) Well Ltd CSI. DEFL. Vert( 0.06 3-6 894 240 180 TC 0.56 Vert(C-1 -0.05 3-6 999 nla SC 0.50 Horz(CT) O.Ot 2 n/a WB 0.00 Matrix - MP 6) Provide mechanical connection (by others) of truss tobearingplatecapableofwithstanding100lbupliftatioint( s) 1, 2• FORCES. ( lb) Max. Comp.IMax. Ten. - All forces 250 (lb) or less except when shown. LOAD CASE(S) Standard NOTES - second gust 1) Wind: ASCE 7-10; Vult=150mp h (3 Vasd=116mph; TCDL=5.0psf; BCDL=5.Opsf; h=25ft; Cat. 11; Exp C; End., GCpi=0.18; MWFRS (envelope) andC-C COrrler(3) 0-0-0 to 343-0, Exterior(2) 3-0-0 to 4- 6-11 zone;C-C for members and forcesate gnpWFRS for reactions shown; Lumber OOL=1.60 p DOL= 1.60 tee rotation 2) Plates checked for a plus or minus 0 deg about its center. 3) This truss has been designed for a 10.0 si bottom pchord live load nonconcurrent with any other live loads. 4) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-" wide will fit between the ther members. PLATES GRIP MT20 244/190 Weight: 14 lb FT = 0% bottom chord and any o connections. min.+h 5) Refer to girder(s) for truss to truss co r n+r I[p;d5.hS-1l.1"eL LlMrsr y;M,rxrns pmdM,ar ^ nUtililidlR W. lr't16,1V Nmdrndrd rn ^nsultar n ld,.p Inn ttldd nml0p wh•^t PFI Ilreropm,aP,n Qlilll flUlSt(OF'fltll (7S171s114t(r; do 6sssd q+t'bi ^M^ rddyln d^,bu.i.dm IM,-144ldl,lai9r•hsrdnr dYn.isM n00"""eS+dtud4 nnum h,y,ty•11 eTCl fllSsuFs(ulrl .rsn,d w+l lo{i4^d'^nsr r itudlFl Thel>t, errtd Mend"11M^llmt a I.wy{nira a^"ndy eim R( Inddstl oAdrrnd5r prd rlaa. Rslrytmrnl,nu d1LIrr+NrPas sm 11 Ita 16'1 hbW1° W aO.m ll(Ir IdhtMhd+l MSM ep ¢erarinnnn wine h IM. d Ndhol;nsd(tEdl nsrM.d NOd^r rrWs+f pdraass d m W" I 11 d11 woni lb Ines hup [Wm n s 11 t Idtlq n all t n 6 isplcec bp^ n d nl'!i) t15Q1 d^du Iscd II a(rtsd(appipbl0 ?oil Allnttn-Aa11o.1Llambl ill, p.l. tepnbdio.dlYis{nanem, in all bra is pso{ibitel ril6cdl the+nllt.p^miuuaban bl lad lnssn Aalhnyl.b^to Anthony T. Tombo 111, P.E. s 80083 44515t. Lucie Blvd. Fort Pierce. FL 34946 Job Truss Truss Type Qb Ply HOMES /SEAGATE v4WRCSG4g9D01CommonSupportedGable1A0182854 AN Reference (optional) Al Roof Trusses, Fort Pierce, FL 34946, design@al truss.com Faun: B.WU S NOV 12 zui i vnni: mizu s nov iz zui r ivn t etc inausures, inc. Mon um; , i , ,.55.5r zu, r rdsu , ID'UumEBPzQXokuwJ2P5W?E2TyuP1 h-MRJ16NwiZ6_UuEflX2lJvtezh7iAVcm6A2k7kLyA3Ua 1-0-0 7-0-0 1440-0 15-" 1 0 0 7-" 7-0-0 1 0 0 4x4 = 5.00 15 _ i i J' 12 lam, •' 3 TY .../ ST1 I I 4 16 ST I I ST3 6 I ST2 17 7 71 ., ST1 I 18 e 9 Qto 3x4 = 14 13 12 11 10 3x4 = 14-0-0 14-0-0 LOADING(psf) SPACING- 2-" CSI. DEFL. in loc) I/deft Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.15 Vert(L-) 0.00 8 n/r 90 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.06 Vert(CT) 0.00 9 n/r 80 BCLL 0.0 Rep Stress Incr YES WB 0.08 Horz(CT) 0.00 8 n/a n/a BCDL 10.0 Code FBC2017frP12014 Matrix-S Weight: 60 lb FT = 0% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 OTHERS 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc puriins. BOT CHORD Rigid ceiling directly applied or 10-M oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. All bearings 14-". lb) - Max Horz 2= -59(LC 13) Max Uplift All uplift 100 lb or less at joint(s) 2, 8, 13, 11 except 14=-102(LC 12), 10=-102(LC 13) Max Grav All reactions 250 lb or less at joint(s) 2, 8, 12, 13, 14, 11, 10 FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 4-13=-115/266, 3-14=-163/265, 6-1 1=-1 15/266, 7-10=-163/265 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=150mph (3-second gust) Vasd=116mph; TCDL=S.Opsf; BCDL=S Opsf; h=25ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (envelope) and C-C Comer(3) -1-M to 2-0-0, Exterior(2) 2-0-0 to 7-0-0, Comer(3) 7-0-0 to 10-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) All plates are 1.5x4 MT20 unless otherwise indicated. 5) Plates checked for a plus or minus 0 degree rotation about its center. 6) Gable requires continuous bottom chord bearing. 7) Gable studs spaced at 2-0-0 oc. 8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrenl with any other live loads. 9) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-" wide will fit between the bottom chord and any other members. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 8, 13, 11 except Qt=lb) 14=102, 10=102. 11) Beveled plate or shim required to provide full bearing surface with truss chord at joint(s) 2, 8. LOAD CASE(S) Standard m.qd•11¢4r ilm rwlrt¢utu mla i camroa tmc rWruuaniow:rrr. ret Nub pnaaf rltdru,rMG.n Eng trr.gjt001rmrogl 1"ll1IW nAm 4Y. nr. liue.n,c4lrMig rl! 141dr: ddmddlr.WI.%40% t"i AN Anthony T Tombo 111, P.E. dne/ d,M,dqh:itbbnyrdli.dYD.w,t.D.ri,rYuA .nah Wiyhv7o.ate+r 4n(.r1.IXrdhtd rY uarlM fY gln.VdE. iMrghll n,/rim,,.M1ie,rgr,.4M rYcq udrany W1.1 180083 dar k.,rtnenao.mM.n.dtmrrrou,rt.riu,4mueeht r,.nsed wse.leWtr,mharsutntr.mNrt dt,w, Initr ,o.mw+aanrw,adinuti *.,trn,on[y.mrim,w.ne.u.rn, 4451 St. Lucie Blvd. da•,. tr' ilh.(.bdgrcl q...,rghap, rand Irum A,*tgraorat .tay on... hn,sJr. [q—d.1 w.1 111,gUd W.,orm Fort Pierce, FL 34946 ptrgM0f11{1- IN IL.,u,ktY r7l.ieal.N.I.L leptdmwdiki,l rnmra,i utln,nr Y hBrlyd6wnR nntnpn iuiuhuA ItwlLnu,A 0 gf.bWlO,I.E. Job Truss Truss Type Qty Ply RYAN HOMES / SEAGATE V4 WRCSG4D9 D02 Common 1 1 A01$2855 Job Reference (optional) uuss.aulrr nun. o. rzu s Nov lz 20i r rnnc tl.1zu s Nov 11 zu1 y MI lek Industnes, Inc. Mon Dec 11 11;35:38 2017 Page'1 ID:UumEBPzQXokuwJ2P5W7E2TyuP1 h-rdt7KjwKKP7LVNEx51GYS5BzRXwWE30FPiUgFfnyA3UZ 1-0-0 7-0-0 8 0 0 9 6 o 11 6 0 13-7-12 1-0-0 7-0-0 1-0 0 1--2-0-0 2-1-12 4x4 = 4x4 = 3x4 = 7-M LOADING (psf) SPACING- 2-" CSI. DEFL. in loc) I/deft Ud TCLL 20.0 Plate Grip DOL 1.25 TC 0.79 Vert(LL) 0.12 5-17 999 240 TCDL 10.0 Lumber DOL 1.25 BC 0.57 Vert(CT) 0.17 5-17 981 180 BCLL 0.0 Rep Stress Incr YES WB 0.12 Horz(CT) 0.01 4 n/a n/a BCDL 10.0 Code FBC2017/TPI2014 Matrix -MS LUMBER - TOP CHORD 2x4 SP No.2 'Except' T3,T4: 2x4 SP No.3 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied or 5-0-8 oc puriins. Except: 54-0 oc bracing: 3-4 BOT CHORD Rigid ceiling directly applied or 6-11-9 oc bracing. MiTek recommends that Stabilizers and requiredcrossbracingbeinstalledduringtrusserection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 4 = 544/0-3-12 (min. 0-1-8) 2 = 608/0-8-0 (min. 0-1-8) Max Horz 2 = 72(LC 12) Max Uplift 4 = 155(LC 13) 2 = 188(LC 12) Max Grav 4 = 544(LC 1) 2 = 608(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-18=-858/691, 3-18=-790f710, 3-19=-790/704,4-19=-863/690 BOT CHORD 2-5=-484f729,4-5=-484/729 WEBS 3-5=-49/314 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=150mph (3-second gust) Vasd=116mph; TCDL=S.Opsf; BCDL=S.Opsf; h=25ft; Cat. II; Exp C; End., GCpi=0.18; MWFRS (envelope) and C-C Comer(3) -1-M to 2-M, Exterior(2) 2-0-0 to 13-7-12 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are 1.5x4 MT20 unless otherwise indicated. 5) Plates checked for a plus or minus 0 degree rotation about its center. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-M wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb) 4=155, 2=188. 9) Graphical pudin representation does not depict the size or the orientation of the pudin along the top and/or bottom chord. LOAD CASE(S) Standard Dead Load Dell. = 1/16 in PLATES GRIP MT20 244/190 Weight: 67 lb FT = 0% rq hrus—voi, n-1113marmn inQ141lNisafOt7 asaslouj4mi ,unC awirtrwIneihop ".dmdrdc n nt1-"b" IN, dhle-11.Woo g11.blu.,SeenMirn, mlr„ b...e rnneln, 1 W11Y rsmi Itf,,tll h r W W 61'J{ n M n11 h, — Oran Iger p r, 51c,ar Intm ;m ur u q a i p—h uFC, r 4 prn WN q mN ny vlary Pit no irh1, A M teJr In„ MnJ oft IOa roll, d m1, N 6up nvgmn 1,q r Cany uatorn ow. 4Oct;T—enroll.Ohm,up-stf.ra,o.nr.%0-1rermdI'd .11od,"or,p,r,.C.Im"d11Lm;dml,dl.r>a11hdMiThgandolPAINCAD! 151r61fen,dygldb 1wrq,,b,naYdbrq,MMlnny Wlnd And'onyT.7ombolll,P.E. of dygrspn dl axf m.s„a,..6rlro aldp,musd eamden bap cq®srn.r,m.Pan pbdrsg rnwvunrd.msr. prr mlrfrsrrr,r.wcsl,danruon,ono.. u.,,onp [q,.dr.0 r,.brx, s,s a 80083 rf. hr ldurl , fitn ,r l up,lrru slrr 6p,m rol WAR mmsvd r..,nnlad l,ml 4451 5t. Lucie Blvd. 1 4 •Ihl*w,hr1.14fnuhu Iq:rnbinY{L!a M Fort Pierce, FL 34946 opyilhl07016A-I Roof bosses-h1hoey1.Tombs 111,t.f. teprdodia.ofAir ioronerd,ionllun,ispmhibilel itheatthe.rineepermission horA-0foul lrnses-AlAoorl.Imh 111,L1. Job Truss Truss Type Qty Ply RYAN HOMES / SEAGATE v4 A0182856 WRCSG4D9 D03 Half Hip 1 1 A. Job Reference (optional) Al Roof Trusses, Fort Pierce, FL 34946, design@altruss.com Run: 8.120 s Nov 12 2017 Print: 8.120 s Nov 12 2017 MiTek Industries, Inc. Mon Dec 11 11:35:38 2017 Page 1 ID:UumEBPzQXokuwJ2P5W9E2TyuP1 h-rdt7KjwKKP7LVNEx51GYS5B7KXxXEuNFPiUgHnyA3UZ 1-0-0 6-8-7 + 9-4-0 13-7-12 1 0 0 6-8-7 2-7-9 4-3-12 3x4 = 3x3 II Dead Load Defl. = 1 /16 in 12 3x4 = 1.5x4 II 5x6 = LOADING(psf) SPACING- 2-" TCLL 20.0 Plate Grip DOL 1.25 TCDL 10.0 Lumber DOL 1.25 BCLL 0.0 ' Rep Stress Incr YES BCDL 10.0 Code FBC2017/TP12014 LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied or 5-10-2 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-5-4 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 2 = 602/0-8-0 (min.0-1-8) 6 = 538/0-3-12 (min.0-1-8) Max Horz 2 = 204(LC 12) Max Uplift 2 = 182(LC 12) 6 = 171(LC 9) Max Grav 2 = 602(LC 1) 6 = 538(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-11=-880/551, 3-11=-769/569 BOT CHORD 2-7=-729/777,6-7=-729l777 WEBS 3-7=0/311, 3-0=-800/755 NOTES- 1) Wind: ASCE 7-10; Vult=150mph (3-second gust) Vasd=116mph; TCDL=S.Opsf; BCDL=S.Opsf; h=25ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (envelope) and C-C Comer(3) -1-" to 2-0-0, Exterior(2) 2-0.0 to 13-6-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Provide adequate drainage to prevent water ponding. 3) Plates checked for a plus or minus 0 degree rotation about its center. 13-7-12 CSI. DEFL. in floc) I/deft Ud TIC 0.67 Vert(LL) 0.10 7-10 999 240 BC 0.50 Vert(CT) 0.11 7-10 999 180 WB 0.82 Horz(CT) 0.02 6 n/a n/a Matrix -MS 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) ' This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-M wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 2=182, 6=171. LOAD CASE(S) Standard PLATES GRIP MT20 244/190 Weight: 63 lb FT = 0% fedq•Mu NegTh rrh•h'sII=ni11[trolj GtlW 111115 e(Ot'ailen MI9%CKTT,'I1[1C1UVJf1[•Wa lerfr k+Ir po.mdrd bM.oll«10np MugllOP,d I. 1rJq I. Ir4 R IL ld—SkM16-enr WoldWnv dN oMNI, Fj dltdloMlrtlset.nd bl ee nebie.dd s111ln1 k1yllq dpl, Srndry 4pe mudngf0lrgrmem.Glredh(.dnd tl rgwulny Werybblbyeddrs>belms Eem1.h100 rdr.d. P4l Rlnplu.gesnldlq ude.>. ublle's Anthony T. Tombo 111, P.E. deudNtmlfugl IAghhmrwlLLWdes Dm.Mbdl. Misr Itd1hWWi34u4dMI. lhgpnddhNld.!bdd d6,1—rldgb ftwq..bddme—War qW6IN.,Msub,d a80083 b inlay DelQldAe: mn hrxlm.I bl l00dhlndusd pllLesldmba q(qrm Sdnr hY-m!(I NIL+1Hhigdtlll mld.nmh lrmlpd.0 mlpA.lMny«eJian dlmndLL«lput,Lnl Wap 6.n ffmtn d Aib, w'nr 4451 St. Lucie Blvd. M.lu edwllle( e-ogd qu aeghdlln*s l.drtf lwl.0 puptg.wueclrl.r'lq trap,«I:ntSlneF.q wdq efq NmilmlMnnnlddb ml. Fort Pierce. FL 34946 OppilY102011AIlrlhisses -Amloy1.Ier- 6eIll. r.1 tegadaioecfibis d m erd,iley f,ispokiEeeddihe ltire rritteepermissin hem Adleaf hesus-Aelheny1.lea!III,p.I. Job Truss Truss Type Qty Ply RYAN HOMES / SEAGATE V4 WRCSG4D9 D04 Half Hip 1 1 A0182857 Job Reference (optional) Al Roof Trusses, Fort Pierce, FL 34946, design@altruss.com Run: 8.120 s Nov 12 2017 Print: 8.120 s Nov 12 2017 MiTek Industries, Inc. Mon Dec 11 11i35:39 2017 Pagc,1 ID:UumEBPzQXokuwJ2P5W?E2TyuPl h-JpRVX3xz5jFC7Xp8eTon_ljA_xHlzLaPdMDDpbyA3UY 1 0 0 6-8-7 11-4-0 13-7-12 1-0 0 6-8-7 4-7-9 2-3-12 3x4 = 3x3 11 3x4 = 1 5x4 11 5x6 = LOADING (psf) SPACING- 2-0-0 TCLL 20.0 Plate Grip DOL 1.25 TCDL 10.0 Lumber DOL 1.25 BCLL 0.0 ' Rep Stress Incr YES BCDL 10.0 Code FBC2017frP12014 LUMBER - TOP CHORD 2x4 SP N0.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied or 5-10-4 oc puriins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-4-3 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 2 = 602/0-8-0 (min.0-1-8) 6 = 538/0-3-12 (min. 0-1-8) Max Horz 2 = 245(LC 12) Max Uplift 2 = 177(LC 12) 6 = 195(LC 12) Max Grav 2 = 602(LC 1) 6 = 538(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-11 =-879/500, 3-11 =-767/518 BOT CHORD 2-7=-751/775, 6-7=-751/775 WEBS 3-7=0/311. 3-6=-802/775 NOTES- 1) Wind: ASCE 7-10; Vult=150mph (3-second gust) Vasd=116mph; TCDL=5.Opsf; BCDL=5.Opsf; h=25ft; Cat. 11; Exp C; End., GCpi=0.18; MWFRS (envelope) and C-C Comer(3) -1-" to 2-0-0, Exterior(2) 2-0-0 to 13-6-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Provide adequate drainage to prevent water ponding. 3) Plates checked for a plus or minus 0 degree rotation about its center. CSI. DEFL. in loc) 1/defl L/d TC 0.67 Vert(LL) 0.10 7-10 999 240 BC 0.50 Vert(CT) 0.11 7-10 999 180 WB 0.83 Horz(CT) 0.02 6 n/a n/a Matnx-MS 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrenl with any other live loads. 5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb) 2=177, 6=195. LOAD CASE(S) Standard Dead Load Defl. = 1/16 in PLATES GRIP MT20 244/190 Weight: 65 lb FT = 0% 4rq rb.uar'qµre•orlr'1IIM1111mrslufnQ111AriN s(OI.tIICY1(IslomjmTir;llucriu Urb,s.(erliYJlpMmdminln hrLmGnpMmylRPdh4Lll IrY41f Ift- nsWr•nr arune•.uwwnmm,.y a1lrYuoemrllnrrMnrullrbfiDbMnut IrrhnrhvpfeporOF. weft gWrt,muaurrTwgnnno-pcuanep8rrmolut—Iquipind"Wobrprlarsr•IinrhpM.1hu"'Mool41 Nkfo ooprn.Ideloamnuorl0'y Anthony T. Tombo 111, P.E. I olnrdbolmrWglrWghhrupd•N!a4Ao.4(IrnrralrharofchlrllnlAupr,ro•uanrinl((W0.'dhbdlrYgn4dlFl il glnul h101dwEdln da•imtrii{IriiFwgr,ufiA6.dYrt JrfMorrtyuNLf a 80083 h hrLal hrpo dli nr. dl oar to lno YtObdar lndur al pdrMrdm berq(rgrm 4dey bbsw(t01J plhrM ll lid Q(l nrdrnrlW porn p•qn RNb1rr»ntrralNu I Innl Lhnr Mupr.lmrinp Igor Irmrrnl¢+•u, a'nr4451 St. Lucie Blvd. do.. Wood IF I[mo met 9.o.og4/I pen lnrhri hlnu coup fW."Is 1o; age Wool ht4w., lnu SIM 1,4—ear" la mtlml r:n rrn MaN a Mi. Fort Pierce, FL 34946 oPTi lif 0 7016 A I lost hissel -Ankly 1. tombs Ill, ?.I. le iododics of this dognment, in soy form, is libifelrifheotlhe ieopaoieoheoAteoflues Aofhoayl.lmbolll,L[. Job Truss Truss Type QtY Ply HOMES / SEAGATE v4 A0182858 WRCSG4DP D05 Half Hip 1 1 RYAN Job Reference (optional) Al Roof Trusses, Fort Pierce, FL 34946, designQa a1truss.com Run: 8.120 s Nov 12 2017 Print: 8.120 s Nov 12 2017 MiTek Industries, Inc. Mon Dec 11 11:35:39 2017 Page 1 ID:UumEBPzQXokuwJ2P5W7E2TyuP1 h-JpRVX3xz51FC7Xp8eTon_lj9pxHhzKEPdMDDpDyA3UY 7ZOOQ 6-8-7 13-4-0 13r 12 1-0-0 6-8-7 6-7-9 0 2 3x3 II 4 3x4 = 1.5x4 II 5x6 = M3 LOADING (psf) SPACING- 2-" CSI. DEFL. in loc) 1/defl Ud TCLL 20.0 Plate Grip DOL 1.25 TIC 0.75 Vert(LL) 0.09 6-9 999 240 TCDL 10.0 Lumber DOL 1.25 BC 0.51 Vert(CT) 0.11 5-6 999 180 BCLL 0.0 ' Rep Stress Incr YES WB 0.85 Horz(CT) 0.02 5 n/a n/a BCDL 10.0 Code FBC2017frP12014 Matrix -MS LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied or 5-10-1 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-3-3 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 2 = 602/0-8-0 (min.0-1-8) 5 = 538/0-3-12 (min. 0-1-8) Max Horz 2 = 288(LC 12) Max Uplift 2 = 163(LC 12) 5 = 247(LC 12) Max Grav 2 = 602(LC 1) 5 = 538(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-10=-882/435, 3-10=-771/453, 4-5=-165/362 BOT CHORD 2-6=-807/779, 5-6=-807/779 WEBS 3-6=0/313, 3-5=-825/847 NOTES- 1) Wind: ASCE 7-10; Vult=150mph (3-second gust) Vasd=116mph; TCDL=5.Opsf; BCDL=5.Opsf; h=25ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (envelope) and C-C Comer(3) -1-0-0 to 2-0-0, Exterior(2) 2-0-0 to 13-6-0 zone;C-C for members and forces 8 MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Plates checked for a plus or minus 0 degree rotation about its center. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) ' This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-" wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 2=163, 5=247. LOAD CASE(S) Standard eo c6rh Dead Load Defl. = 1116 in PLATES GRIP MT20 244/190 Weight: 66 lb FT = 0% ory Mu Mwdlr rr.h.nr'1I Im R=(V1In61I;11ITI NSIfOF IIICN(RI(Ixj wl.T;lweRErJ[II• I& Iedl hop Pmrmrrrmr. IV, I—" 1.1.4(norr eNr I lrra I I hhmSlM Mhvm Wrr, diff.nr uWnd IN. rh OhYr rmrr[n,M.ndM6lol b taro nr has kw lrp.e p r, wet hyFV4W wee "rr 11111'4 mr..F-t or ptrsud'n-"I rs"W rr 'ew I" Id Ims * hn, L7nd ntr no r¢, k TNI. III, enp nrgern he1gr.0a."'4d" Anthony T. Tombo ill, P.E. I rnrtb,ImsWgl.xnp 1,h rnpruYW!thD.srr.k0.n,ribmdr)<trb Nty h,Tr,.trundtbr oL SrCr Mhd I.Slg NrrlRL lk xndthlCld.!kll nr Is Ar Irs" 1rq l.nti myr. Wall. r k.q deo k rnyruun t 2 80083 rorwgkspnr(r sn to o„o M.dmornpmu,rAe&u, d INb gcgr,nU"b"M(AMPWIM4IM.9 fLL1 wdswrld*Al-trrlr rt l—MI YSr,yrnHn ad Mn atlblFn, kup.,I—AIM brem as rm,t rti v,.,u 4451 St. Lucie Blvd. nv.iu ltirll rfrn7 yrd rwo.rq lr tl prtn bird Or Inss hutlreurnl,IAt r. ltlghup.,. Ns sro. hprrnd.lrq L11cmd W.1lanetnibilll Fort Pierce, FL 34946 GppipN07(IIAAIbdLosse- Aelrgl.loml/lll,l.t. tristwod'roddisbmnem,msly firm, ispolil'drA ilYeNthe tinnee permissive hem A-Itool lmsn-Anbnrl.lwloIII, p.l. Job Truss Truss Type City Ply RYAN HOMES / SEAGATE V4 WRCSG4D9 E03 Half Hip Girder AOf82859 JobRefer nce o tional Ay Roof Trusses, Pon Pierce, FL 34946. design@attruss.com Run: 8.120 s Nov 12 2017 Print: 8.120 s Nov 12 2017 MiTek Industries, Inc. Mon Dec 11 11;35:40 2017 Page 1 ID:IhohHggcR5jfhi7ZLg 1 IoUyiKGA-nO?tlPybs 1 N3lhOKCAJOXWGSwLYvi_3YsOzntgyA3UX 1-0-0 3-0-0 6-0-0 1 0 0 3-0-0 3-" 4x4 = Dead Load Defl. = 1/8 in 2x4 = 1.Sx4 11 10-4-0 0-4-0' 3-0-0 2-841 6-0-0 3-" LOADING(psf) SPACING- 2-" CSI. DEFL. in loc) I/defl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.21 Vert(LL) 0.19 6 365 240 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.76 Vert(CT) -0.18 6 395 180 BCLL 0.0 ' Rep Stress Incr NO WB 0.04 Horz(CT) -0.00 2 n/a n/a BCDL 10.0 Code FBC2017/TP12014 Matnx-MP Weight: 23 lb FT = 0% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP N0.2 WEBS 2x4 SP No-3 BRACING - TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc puriins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 5 = 252/0-3-8 (min. 0-1-8) 2 = 333/0-3-8 (min. 0-1-8) Max Horz 2 = 77(LC 8) Max Uplift 5 = 183(LC 5) 2 = 224(LC 4) Max Grav 5 = 252(LC 1) 2 = 333(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=150mph (3-second gust) Vasd=116mph; TCDL=5.Opsf; BCDL=5.Opsf; h=25ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (envelope); porch left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) Provide adequate drainage to prevent water ponding. 3) Plates checked for a plus or minus 0 degree rotation about its center. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-M wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb) 5=183, 2=224. 7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 82 lb down and 107 lb up at 3-0-0, and 41 lb down and 53 lb up at 5-0-12 on top chord, and 99 lb down at 3-0-0, and 23 lb down at 5-0-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25 Plate Increase=1.25 Uniform Loads (plf) Vert: 1-3=-60, 3-4=-60, 5-7=-20 Concentrated Loads (lb) Vert: 3=-11(B) 6=-11(B) 12=-17(B) 13=-19(B) r.aq•rye.,q,r.tl.n.•rIimrirrirumnmlmTEN& e"y hop" .mr,db.n,.n'I""o.,jlrW,.Wb1eWj1I.ra11IrI. Skfflksrtl, nmmrm rtt„mrnNa a.I>t.r.0 hoplq.tlpr.spalbpmr,mw..Ialrq,r.r,.*up-dINpd.,.dow,vinWA01r,nrlwpdm,grincrrardnINTM,dI.NWMi. Irb.pm-pranry,.m.>.carry I dNrMlm,hr.i{ralnlh6rnpaNar,d4Am.M0.ar,uMrrl r ln Or ldLgdupr,t6r.rn rlW liLL d Wbd lnY rW dlM1l ih gpmlr6lGDdmCdl nrdnrfmr. kirOq 1.fJry Aigr, hrnM.dktul'a r.r"ouokjJl d ony T.2 Tomb80083 III, PI: a f10083 rrwyOnptldcaernn. l0.t„tlatltbNDd.,r r,.lpWnndM.dtq(y.mtdrgllr.m.imllpWJelpllldUUnrdtrtrarpndpJ>d.IM1IrS.,Lrnpn laain.lrtnd4li.,hope, hmrnpFq.ndlmt6tar,tl,am 4451St. Lucie BNd. e..,.bi-01 iGtaarpdq.. a.gloomly a. III, . mu naaial If.reldr.n, In IIIfu hs proki t wr. I w>, wuy,d.t..r. rdmb lni Fort Pierce, FL 34946 OppitMOt0lfAlbd Lnse, Amlaryl hm6r lll, H. tep,oioaiar dllia iamnem,mutlur,i, pratilitd.rflatl the rrirtea pemissin hm Ad laalhn,e,•ArlhmrLbnkoIII, f.l. Job Tn,ss Truss Type aty Ply RYAN HOMES / SEAGATE V4 A0182860 WRCSG4W E04 Half Hip 1 1 u Jab Reference (optional) A7 Roof Trusses, Fort Pierce, FL 34946, design@altruss.com Run: 8.120 s Nov 12 2017 Print: 8.120 s Nov 12 2017 MiTek Industries, Inc. Mon Dec 11 11:35:41 2017 Page 1 ID:I hohHggcRSjfhi7ZLg 1 IoUyiKGA-FCZFykzDdKVwMrzW mugF3jpRMlyxRR7h5giKt6yA3U W 1W 5-0-0 5-" 100 LOADING( psf) SPACING- 2-M TCLL 20.0 Plate Grip DOL 1.25 TCDL 10.0 Lumber DOL 1.25 BCLL 0.0 ' Rep Stress Incr YES BCDL 10.0 Code FBC20171TPI2014 LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 9-11-9 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, In accordance with Stabilizer Installation guide. REACTIONS. ( lb/size) 5 = 211/0-3-8 (min.0-1-8) 2 = 317/0-3-8 (min.0-1-8) Max Horz 2 = 117(LC 12) Max Uplift 5 = 156(LC 9) 2 = 193(LC 8) Max Grav 5 = 211(LC 1) 2 = 317(LC 1) FORCES. ( lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 3- 4=-103/272, 4-5=-133/274 BOT CHORD 2- 12=-272/103, 12-13=-272/103, 5- 13=-272/103 NOTES- 1) Wind: ASCE 7-10; Vult=150mph (3-second gust) Vasd= 116mph; TCDL=S.Opsf; BCDL=S.Opsf; h=25ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (envelope) and C-C Comer(3) -1-0-0 to 2-0-0, Exterior(2) 2-0-0 to 5- 10-4 zone; porch left and right exposed;C-C for members and forces 8 MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Provide adequate drainage to prevent water ponding. 3) All plates are MT20 plates unless otherwise indicated. 4) Plates checked for a plus or minus 0 degree rotation about its center. Jx — 3x4 = 3x8 MT20HSII 500 MT20HSII CSI. DEFL. in loc) I/deft Ud TC 1.00 Vert(LL) 0.09 5-10 789 240 BC 0.46 Vert(CT) 0.08 5-10 908 180 WB 0.00 Horz(CT) -0.00 2 n/a n/a Matrix - MR 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) ' This truss has been designed for a live load of 20. 0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-" wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint( s) except Qt=lb) 5=156, 2=193. LOAD CASE(S) Standard PLATES GRIP MT20 244/190 MT20HS 187/143 Weight: 23 lb FT = 0% an• n.nendrah.tr•IIIMn3smruuu3a0uRub U41Md[rpnenndrtdedn.ne .,7e}Qug(TIVd6le.11ln4grf Idun,Yen4ken, udn,dknudawnalol,.q Mlleluumrlo„ e114 edh trnt.4rdA 1,eLn, kvp ley.apr, Srudrytepr;mudnnna u nm,..npodnrdnwd q e:utrty.wary br o,ln'dl4 raj, Intt lgnNnMl06 rry, d.IM1I, hLwpnvapw.Iwq,rmxt,mdlF1 Anthony T. Tombo III, P.E. tdeudbfm,funlalAerhtriur.,hlardtrUen.trOm,ealrtrelef•ntr Wlnr tnMer,atri.nndtr1440tdtriedlaYaa,e/,dlFl i4 atn,ddtr[Malin nne ledtrIns—d"W4 nigd e.inhIanYnar" Islia rtqu%Us! d z80083 trwar4s4sudend,wtiidµ. 0 rte.san„nw.rlrodtr ,afn,dtr4ag4y.mfadlm... ru4lhlndsul,.4451St. Lucie Blvd. n e.ldaelileftaad geel a. mryal. 0 nd ei f4on dur[e nrhltld satear.,.In„57eRa fe e.dn pdfer Nafla l4rnnnldaal4RII Fort Pierce, FL 34946 eppitMO7011A4loaf hessn-Amiasy1.Iambs Ill, b 1.1 hpomaednisdnoneai,usay Iva, isp,olill4driAenitrnneeptlmissiuhissAdloafLases-AalieayLlentoIII, L1. Job Truss Truss Type Dty Ply RYAN HOMES / SEAGATE v4 WRCSG4D9 HJ3 Diagonal Hip Girder 1 1 A0182861 Job Reference (optional) Al Roof Trusses, Fart Pierce, FL 34946. design@altruss.com Run: 8.120 s Nov 12 2017 Print: 8.120 s Nov 12 2017 MiTek Industries, Inc. Mon Dec 11 l li35:41 2017 Pagel I0:agpjYE3xuPBoBiIH6PrSYazz2of-FCZFykzDdKVwMrzWmugF3jpcCl l SRR?h5giKttyA3UW 1-5-0 4-2-3 1-5-0 4-2 3 — 2x4 = 0-5-11 3-8-8 1- LOADING (psf) SPACING- 2-" CSI. DEFL. in (loc) 1/deft Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.31 Vert(LL) 0.01 4-8 999 240 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.17 Vert(CT) 0.01 5 999 180 BCLL 0.0 ' Rep Stress Incr NO WB 0.00 Horz(CT) 0.00 3 n/a n/a BCDL 10.0 Code FBC20171TPI2014 Matrix -MP Weight: 15 lb FT = 0% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 BRACING - TOP CHORD Structural wood sheathing directly applied or 4-2-3 oc puriins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 3 = 73/Mechanlcal 2 = 262/0-5-12 (min. 0-1-8) 4 = 8/Mechanical Max Horz 2 = 88(LC 4) Max Uplift 3 = 58(LC 8) 2 = 214(LC 4) 4 = 25(LC 5) Max Grav 3 = 73(LC 1) 2 = 262(LC 1) 4 = 46(LC 3) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=150mph (3-second gust) Vasd=116mph; TCDL=S.Opsf; BCDL=S.Opsf; h=25ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (envelope); porch left exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) Plates checked for a plus or minus 0 degree rotation about its center. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-" wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3, 4 except (jt=lb) 2=214. 7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 62 lb down and 52 lb up at 1-4-9, and 62 lb down and 52 lb up at 1-4-9 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25 Plate Increase=1.25 Uniform Loads (plf) Vert: 1-3=-60, 4-5=-20 Concentrated Loads (lb) Vert: 9=71(F=36, B=36) eq•nwn.le.re.b.d'111srnlsml•uu(nm:wnuulroealrcnmlo farruu¢ntrutrrd lwlrull w endRdun.ml n,mr e.,lrradrlrrn l hal(.h(.e.ewaw.,ne u+n,en.ma r mm, y mlbsesen eti, seflrmekhe gD MNd U.1-Dedp lees ore, sMamlEnw,;mwwnmupn.b mji-xne+nmed rgHrlgn+e.vlWrd ln*aa,gr un,M.Henn. Me" re MI. nines es.*mAnthony T. Tombo ill, P.E. dn, dan1.,'vmrl ley1,dinrw kW!d40.en.oeD.wr,t AevNep vhMWgOnipeSetriwnndWDYWR.'dMbdl'Ign4edlFl Ihgpnddw101eeeeqbdenedmlm,eeddgW4mrgr.b,h or 1Yngwlhneiul dlllyd a80083 h l,r'ly Dngn d (eerar. ell ores rd o a be ND ed ra peon, ns redo., d N heYq (ryorm Sdrlr eQe mor (i01J pm,w h fll eee II(A en du and fa pnd pj ml Lrs L n,pnbeen.eeeen e' 4 bm hvpr, tin, hsp Fe v of fMt rMrtrv, aen Avdu ldnw lr e(e ia eped nrrrrmglr dl pan .ehri lh N. hppfwu 1, e01 no lilq hsgr,n hn, srns hp. e.1 odlg W feaM :snnlehd boll 4451 er Lucie Blvd. For( Pierce, FL 34946 I Gppipb1 0 2016 A 111411 lmses • Aesboq 1. lembe U01. tepreleaial of dis I mmem, in al form, is problbild rilkerl rise vdirn permission hem A-1 IM Tresses - Aolhoar 1. lido III, P.I. Job Truss Truss Type QN Ply RYAN HOMES / SEAGATE V4 A0182862 WRCSG4D,g HJ6 Diagonal Hip Girder 2 1 Job Reference (optional) Al Roof Trusses, Fort Pierce, FL 34946, design@altruss.com Run: 8.120 s Nov 12 2017 Print: 8.120 s Nov 12 2017 MiTek Industries, Inc. Mon Dec 11 11:35:42 2017 Page 1 ID.UumEBPzQXokuwJ2P5W?E2TyuPl h-j07eA4zrOedn_?YjKbLUcxLiiBEeAslrJKSuQYyA3UV 1-5-0 4-10-11 8-5-1 1-5-0 4-10-11 3-6-7 Drd Load efl. = 1/8 in c N N N 4x4 = 8-5-1 8-5-1 3x4 = LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in loc) I/deb Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.58 Vert(LL) 0.16 6-9 616 240 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.75 Vert(CT) 0.29 6-9 349 180 BCLL 0.0 ' Rep Stress Incr NO WB 0.19 Horz(CT) 0.01 6 n/a n/a BCDL 10.0 Code FBC2017/rP12014 Matrix -MP Weight: 34 lb FT = 0% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 9-0-13 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 4 = 123/Mechanical 2 = 397/0-10-15 min. 0-1-8) 6 = 333/Mechanical Max Horz 2 = 149(LC 4) Max Uplift 4 = 98(LC 4) 2 = 270(LC 4) 6 = 190(LC 8) Max Grav 4 = 123(LC 1) 2 = 397(LC 1) 6 = 333(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-10=-569/299, 3-10=-518/307 BOT CHORD 2-12=-381 /541, 12-13=-381 /541, 13-14=-381/541, 6-14=-381/541 WEBS 3-6=-580/409 NOTES- 1) Wind: ASCE 7-10; Vult=150mph (3-second gust) Vasd=116mph; TCDL=S.Opsf; BCDL=S.Opsf; h=25ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (envelope); Lumber DOL=1.60 plate grip DOL=1.60 2) This truss is not designed to support a ceiling and is not intended for use where aesthetics are a consideration. 3) Plates checked for a plus or minus 0 degree rotation about its center. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) - This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-M wide will fit between the bottom chord and any other members. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4 except Qt=lb) 2=270, 6=190. 8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 38 lb down and 47 lb up at 4-2-8, 41 lb down and 47 lb up at 4-2-8, and 68 lb down and 97 lb up at 7-0-7, and 71 lb down and 98 lb up at 7-0-7 on top chord, and 16 lb down and 52 lb up at 1-4-9, 16 lb down and 52 lb up at 1-4-9, 10 lb down and 14 lb up at 4-2-8, 13 lb down and 49 lb up at 4-2-8, and 32 lb down at 7-0-7, and 36 lb down and 85 lb up at 7-0-7 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25 Plate Increase=1.25 Uniform Loads (plf) Vert: 1-4=-60, 5-7=-20 Concentrated Loads (lb) Vert: 11=-84(F=44, B=-40) 12=71(F=36, B=36) 13=-17(F=-9, B=-9) 14=-68(F=-36, B=-32) rhq.l— 139 nrtsarsnsnry rtrus rtuls IM11 US1011 Vm;l(UCVOWFr ha Tail hYp Nndmdroluln.Mlint rn}b"(wd Y hY111Kh411.1bitnn Slownt adma .n'dW. *Iww? YthlurmnlaitmY hb r.dd 11,1.,kgrlgrllr r or.Abpvl'mrug101 tp dnom. t¢mr rdotpOtdrdr P.Inntp,Ndg M V.lnp d.r wo rnu ltrmd. ar l00all, wM na drum or mor hdqummn—" Anthony T. Tombo III, P E I i ydlxO.nhO.Tit,.svdgfrorhJlgkaprr,. orc,mndh,ll(,NComl.dlrLgidrdlRl.Thgpuldnr110dr!Oddnrdm(n1t..7dglx7fSgtq,,hthMdqtngr rY."irhAd+(d 280083 h t".1 hip. d(a+xM.l- nts'st'so 11-] so "a lk TODdr. lrm,.d pldntd.r hum(rgrtn sday tb.m.(01)*tlal 4 IN d Stilt tdunl'h. pid pilau MlYin inntpWurt rdimn d 6 lint kupr. lint ky, l•pr adlnv.., W., 4451 St. Lucie Blvd. in nndddi.1n1.For( Pierce. FL 349a6 lbd- An uTL1dx6.11l,r.1.teptdmia.dAitireonem, io.glertiiiptol3dd illende+nslnpermi(six6mA-Ilodlnun-ArArer(.bokolll,l.(. Job Truss Truss Type City Ply RYAN HOMES / SEAGATE V4 WRCSG4D9 HP Diagonal Hip Girder 2 1 A0182863 Job Reference (optional) Al Roof Trusses, Fort Pierce, FL 34946, design@allruss.com Run: 8.120 s Nov 12 2017 Print: 8.120 s Nov 12 2017 MiTek Industries, Inc. Mon Dec 11 11 35:43 2017 Page ID:UumEBPzQXokuwJ2P5W?E2TyuP1 h-BbhONQ_T8ylec96vtJsj98uwsYeZvF7_Y_BRyyA3UU 1-5-0 5-2-9 9-10-1 1-5-0 5.2-9 4-7-8 2x4 = 1.5x4 II 5 3x4 = 5.2-9 4-7-8 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in loc) I/defl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.42 Vert(LL) 0.09 6-7 999 240 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.51 Vert(CT) 0.08 6-7 999 180 BCLL 0.0 Rep Stress Incr NO WB 0.41 Horz(CT) 0.01 5 n/a n/a BCDL 10.0 Code FBC2017/TPI2014 Matrix -MS Weight: 41 lb FT = 0% LUMBER - TOP CHORD 2x4 SP N0.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied or 5-11-13 oc puriins. BOT CHORD Rigid ceiling directly applied or 6-7-9 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed dunng truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 4 = 137/Mechanical 2 = 474/0-10-15 (min. 0-1-8) 5 = 356/Mechanical Max Horz 2 = 169(LC 4) Max Uplift 4 = 101(LC 4) 2 = 356(LC 4) 5 = 297(LC 4) Max Grav 4 = 137(LC 1) 2 = 474(LC 1) 5 = 356(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-11=-934/621, 3-11=-868/629 BOT CHORD 2-13=-700/867, 13-14=-700/867, 7-14=-700/867, 7-15=-700/867, 6-15=-700/867 WEBS 3-7=-183/275, 3-6=-923/744 NOTES- 1) Wind- ASCE 7-10; Vult=150mph (3-second gust) Vasd=116mph; TCDL=5.Opsf; BCDL=5.Opsf; h=25ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (envelope); porch left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) Plates checked for a plus or minus 0 degree rotation about its center. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-M wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb) 4=101, 2=356, 5=297. 7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 41 lb down and 47 lb up at 4-2-8, 41 lb down and 47 lb up at 4-2-8, and 71 lb down and 98 lb up at 7-0-7, and 71 Ib down and 98 lb up at 7-0-7 on top chord, and 62 Ib down and 52 lb up at 1-4-9, 62 lb down and 52 lb up at 1-4-9, 17 lb down and 49 lb up at 4-2-8, 17 lb down and 49 lb up at 4-2-8, and 40 lb down and 85 lb up at 7-0-7, and 40 lb down and 85 lb up at 7-0-7 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25 Plate Increase=1.25 Uniform Loads (plf) Vert: 1-4=-60, 5-8=-20 Concentrated Loads (lb) Vert: 12=-83(F=-42, B=-42) 13=71(F=36, B=36) 14=-17(F=-9, B=-9) 15=-71(F=-36, B=-36) r..eq.n„ullm.gllrrn.WAIIMTIMru n CEIR11. tibu A Wmcis WOKCtOrr; Lluclu"Ir his, T,,tr 64 p—vmdrdornr.rest—aspauryJI'MWrrL1wr11rYRll.hhrnrSWW—r 0,.y tulh uo.mirrft shah.:.lhdiw ok'&I Anthony T. Tombo 111, P.E. d.udLitmrA+yWL.{h6iup.1lWdheanrt.MO.+rirrx•¢MrxfrorWlnrpup.•.vhreinAarl4VSWOrhdlr,Y drWIFI 1.pndraM1101d Ydln.dr.ImtdM ls(iyvi.rr.bmArlr.Wkn+aJfllrlrrv{roMr0 a80083 rt. h.yay kWW Ew". N etafm M e se mh W to V w,rV ptlon hh•emr. nedIh"femam Srim(KSOPUsedh in me SIU mrfrn.e•F-alPAW. MI Ybtpet rlr. neoW MM V 1,1w0...yr.1— kup(qu. rN imt rwu ldud lr. (.xaagdep.tarmq It rn pnn iwd.N ih lnv t.set[ymrtleCld{i tar hupr,nimsl(oa E.ywvfor Mir, NwtJml R:n rr a/reaN bll{I 4451 Lucie Blvd. Fort Pierce, FL 34946 rP1TipMO7hl{Ad ialImttet Aehoty I. ImAe III,1.1. lepnleaic. of this domeent,ie ny luo, is pidiluel ritheel the+riaee permissin hen bI Icol hesses• Asiheoy I Leto III, r.I. Job Truss Truss Type Oty Ply HOMES /SEAGATE v4WRCSG4D9J3Jack -Open 21AO182864CANReference (optional) Al Roof Trusses, Fort Pierce, FL 34946, design@altruss.com Run: 8.120 s Nov 12 2017 Print: 8.120 s Nov 12 2017 MiTek Industries, Inc. Mon Dec 11 11:35:44 2017 Page 1 ID:UumEBPzOXokuwJ2P5W?E2TyuP1 h-fnEOam?5vFIVDlh5RONyhMRBgy2Feok8nex_URyA3UT 1-0-0 3-0-0 1-0 0 3-0-0 3x4 = LOADING(psf) SPACING- 2-M CSI. DEFL. in loc) I/deb Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.22 Vert(LL) 0.02 4-7 999 240 MT20 2441190 TCDL 10.0 Lumber DOL 1.25 BC 0.23 Vert(CT) 0.02 4-7 999 180 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) 0.00 3 n/a n/a BCDL 10.0 Code FBC2017/TPI2014 Matrix -MP Weight: 11 lb FT = 0% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SIR No.2 BRACING - TOP CHORD Structural wood sheathing directly applied or 3-0-0 oc puriins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 3 = 71/Mechanical 2 = 188/0-8-0 (min.0-1-8) 4 = 37/Mechanical Max Horz 2 = 75(LC 12) Max Uplift 3 = 49(LC 12) 2 = 119(LC 8) 4 = 36(LC 9) Max Grav 3 = 71(LC 1) 2 = 188(LC 1) 4 = 52(LC 3) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=150mph (3-second gust) Vasd=116mph; TCDL=5.Opsf; BCDL=5.Opsf; h=25ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (envelope) and C-C Comer(3) -1-M to 2-0-0, Exterior(2) 2-0-0 to 2-11-4 zone; porch left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Plates checked for a plus or minus 0 degree rotation about its center. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-" wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3, 4 except Ot=lb) 2=119. LOAD CASE(S) Standard mdg mnrn.ndy,h. r eitwrnnsafs[wrtartuna[srt0ea M(1111011[cm;t(ncrawisrkwlney6JrNndmdrnlmin M1ttins MrpYugIN, dhedlyl.links RILhhrtarSkmWins ne e+nren.r.wdnalor..y nta.enter,,uartutmrt»hhrddhetnsteapt¢ rap..spa(t.wnuwnglotrgmno v dnpdndwnFwarmr•wegMnen*drrgt(n:ratmtom(rotd(.r.r}(lrewpnugew(rque uadu Anthony T. Tombo 111, P.E. I Inedblmebgl.4nth4rty rMlndnPrur. MOmrooavdrpn6NW hvpr,.y tndorRl,WC IhbdlrYgWtdfM1( ingp dddMinil ! L.ndAmT., WqW4mnp.YrhM yh, grHl orny vllnd a 80083 ottwgn,g nd(eema. tu nraen.dmod pmr.t*udm,dmo-aq(.petdsdmm m.(tagtdasWegrndsusntrd ewrp idp.time.l yrs t tnynwtntrutw,dulinenur..finsDelp,f.n.arMrv,..tr,.,r 4451St. Lucie Blvd. dr'la ldud lia Gtedq Iq.rl0g tr dl Finn indnL lW in. tot Y t"39 Wsgr, a limn s(ma F tn d q on" in wtlud trn at n taut h RN Fort Pierce. FL 34946 eppillo 0701d Abellnstes Aatloq l. lacba111.1.1. Ittpubdiaadthis dem,oeal, is all fares, is prol3hd ritletl litrnttes pemissieoben Ad heilasses-An6enyt. boloill, P.I. Job Truss Truss Type City Ply RYAN HOMES / SEAGATE V4 WRCSG4D9 J6 Jack -Open 5 1 A0182865 Job Reference optional Al Roof Trusses, Fort Pierce, FL 34946, design@altruss.com Run: 8.120 s Nov 12 2017 Print: 8.120 s Nov 12 2017 MiTek Industries, Inc. Mon Dec 11 11(35:44 2017 Paged 1 ID:UumEBPzQXokuwJ2P5W?E2TyuP1 h-fnEOam?5vFIVDlh5RONyhMR2Xyzleok8nex_t1RyA3UT 1-M 6-)-0 6.0-0 1 2x4 = 6-0-0 Dead Load Den. = 1/16 in Plate Offsets (X,Y)— 2:0-1-2,0-041 LOADING (psf) SPACING- 2-" CSI. DEFL. in loc) I/deft L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.62 Vert(LL) 0.11 4-7 653 240 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.51 Vert(CT) 0.13 4-7 559 180 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(CT) 0.00 3 n/a n/a BCDL 10.0 Code FBC2017/TPI2014 Matrix -MP Weight: 20 lb FT = 0% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 BRACING - TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be Installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 3 = 155/Mechanical 2 = 303/0-8-0 (min. 0-1-8) 4 = 78/Mechanical Max Horz 2 = 135(LC 12) Max Uplift 3 = 110(LC 12) 2 = 90(LC 12) Max Grav 3 = 155(LC 1) 2 = 303(LC 1) 4 = 109(LC 3) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=150mph (3-second gust) Vasd=116mph; TCDL=5.Opsf; BCDL=5.Opsf; h=25ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 5-11-4 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Plates checked for a plus or minus 0 degree rotation about its center. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-" wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2 except Qt=lb) 3=110. LOAD CASE(S) Standard ndq-hers Arso.rrn.tt.'A I na IU1s6 rumnanuIrRAS A ferdrhdppmm!.drd mes. It, lmr hip h1.rg1ft0!d!reA.tl trh4rl ddnn AMMrsnl binsdkm dddnsrlhl,.d mhYroemreritsNlnrsdlubf7hhkdd hrhnrhup19-01.Will1r"'S.endreirnomptsm.mpudriephutieslul agrntrNa fW0.I.vdmremhnsdreotdr.MfODwlt,nol.MI eds pnUaplu h11g11wwLt.miln Anthony T. Tombo 111, P.E. ZtrdnedhahmshrnrinlhgntkinpvkfmdwQmi'lle ri sedkvd rpin b ham Dupr,ntrnWn dirt llt44 dde W Wgde d lFl lh prndddi00daYetlnrdmfmi airCglref; aigl. hurAor dknq srdlk or nyrWtttd =80083 of hrFq hrp dfan.rr m.srwln adl ippddrtlmnsad pdemisdm hdlq(grm sdtlr Flnm.It611pYnkehllld4nl merlhrN h pndpdu RFlmYrr lrrrspsdfan WYlndlrhmsh Iimrin rllrns daMr. u..hst p'' p'O 4451 er Lucie Blvd. rlu. lu Mnd 111[aY.t rlltl ap n.rmghdl pn lndrri Nhnv hup [apenh 101YId lg hvp,nL :s siee+ER.radq Mlg Ifl uddzd h•nnn Mad.Irll Fort Pierce, FL 34946 bptTilhi0tll6AdAdGusses AmkagLbmhr111,r.I, teprod+dionofikisdommem,inall firm, isprolihiledeirheotihe.rine+termissie hem A-Iled hisses -Aerhoar1.lamtoIII, l.l. Job Truss Truss Type Qty HOMES / SEAGATE v4 A0182866 WRCSG4D9 J7 Jack -Open 12 Fy 1 RYAN Job Reference (optional) Al Roof Trusses, Fort Pierce, FL 34946, design@altruss.com Run: 8.120 s Nov 12 2017 Print: 8.120 s Nov 12 2017 MITek Industries, Inc. Mon Dec 11 11:35:45 2017 Page 1 ID: UumEBPzQXokuwJ2P5W?E2TyuP 1 h-7zomo60igZ?MrSGH?kuBEZz9mMHzNF_HOIgY1 tyA3US 1 0 0 7-0-0 1-0-0 7-0-0 3x4 = 7-0-0 Dead Load Dell. = 1/8 in LOADING(psf) SPACING- 2-M CSI, DEFL. in floc) Well LJd PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.85 Vert(LL) 0.18 4-7 462 240 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.64 Vert(CT) 0.24 4-7 349 180 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) 0.00 3 n/a n/a BCDL 10.0 Code FBC2017/TP12014 Matnx-MP Weight: 23 lb FT = 0% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 BRACING - TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc puriins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 3 = 183/Mechanical 2 = 342/0-8-0 (min.0-1-8) 4 = 91/Mechanical Max Horz 2 = 156(LC 12) Max Uplift 3 = 129(LC 12) 2 = 99(LC 12) Max Grav 3 = 183(LC 1) 2 = 342(LC 1) 4 = 128(LC 3) FORCES. (lb) Max. Comp /Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=150mph (3-second gust) Vasd=116mph; TCDL=S.Opsf; BCDL=5.Opsf; h=25ft; Cat. 11; Exp C; Enc1., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) -1-0-0 to 2-M, Interior(1) 2-0-0 to 6-11-4 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Plates checked for a plus or minus 0 degree rotation about its center. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrenl with any other live loads. 4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-" wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2 except at --lb) 3=129. LOAD CASE(S) Standard y MuNpYi rwh.hYl I= nyffir anal-UrEwlIrM4lLrrhmsisow—, mudw"GtY hO sej ruhlr emrl'd„tilYeulhhlAD k W h,lrn,AISQ,I,/.I,,SII.m1l,p,r Oru nolfeDl4ae.,.II a hp1„W Iq.„vpny u111ryAihln}ihuyr4n,tryfilnhIDD h,,W.IN1 IYWp6ir,n.1 equmo tum" I AnthonyT. Tombo 111, P.E. n1aAb, Im,heryWtepMhn,1,iWlhO.en.h0.ai,nr vNn fahldlnGeupr,.hrwptl hnLSrC IO,Iw11.1>tinlr illll ll,r,N/hlGOdm ellnrdhlmt.i3O bliy,ai 6mMEin IYn{,M OrnquYlUd a80083 hru. rn,Qndtwm..to a,w.+.hmodh n,.lydr.nampa yt r.mtegm.m. rwodglnwvumrd,ad%F.Wpaa. 4451St. Lucie Blvd. drr.w wr ll e t x.a q,d ..me y a r.:n 1 4ra the 1n„ hoplop. ¢I h rrig k4ots.I..- S" t a nr rtq In gd,d erns n rr d ml. Fort Pierce, FL 34946 oppqA101616AIled better • Wool, l.led* [I),p.1. fepnlraics81 Air duntal, is all INC, it proltiliatil eifice the witice permissive hem A -I lost livises - Arrhosy T. logo III, P.L. Job Truss Truss Type Qty Ply RYAN HOMES / SEAGATE V4 WRCSG4D9 J7P Jack -Open 2 1 A0182867 Job Reference (optional) n r nwr r ruaaea, rent rrer ex, rr- .>v*qo, uesign(,cua rrruss.com Run: 8.i2u s Nov 12 201 r Print: 8.120 s Nov 12 2017 MiTek Industries, Inc. Mon Dec 11 1 35.46 2017 Page 1 ID:UumEBPzQXokuwJ2P5W?E2TyuP1 h-cAM8?Sl MRt7DTcrUZRQQmnWOCmbr6gHREyQ5'1JyA3UR 1-0-0 4-0-6 7-0-0 1 0 0 4-0-6 2-11-10 Dead Load Dell. = 1/16 in 4x4 = 3x4 = LOADING (psf) SPACING- 2-M CS1. DEFL. in loc) I/defl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.61 Vert(LL) 0.26 6-9 317 240 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.73 Vert(CT) 0.22 6-9 375 180 BCLL 0.0 Rep Stress Incr YES WB 0.19 Horz(CT) 0.00 5 n/a n/a BCDL 10.0 Code FBC2017/TPI2014 Matrix -MP Weight: 28 lb FT = 0% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc pudins. BOT CHORD Rigid ceiling directly applied or 5-1-7 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, to accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 4 = 61/Mechanical 2 = 342/0-8-0 (min.0-1-8) 5 = 212/Mechanical Max Horz 2 = 156(LC 12) Max Uplift 4 = 56(LC 12) 2 = 198(LC 8) 5 = 163(LC 9) Max Grav 4 = 61(LC 1) 2 = 342(LC 1) 5 = 212(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-10=-310/325, 10-11=-286/329, 3-11=-251/336 BOT CHORD 2-0=-550/280 WEBS 3-6=-323/635 NOTES- 1) Wind: ASCE 7-10; VuIt=150mph (3-second gust) Vasd=116mph; TCDL=5.Opsf; BCDL=5.Opsf; h=25ft; Cat. 11; Exp C; End., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) -1-0-0 to 2-", Interior(1) 2-0-0 to 6-11-4 zone; porch left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Plates checked for a plus or minus 0 degree rotation about its center. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4 except Qt=lb) 2=198, 5=163. LOAD CASE(S) Standard r1(OrCltltll(1119Rj 61:1",1((rCaltKa(Rtrr. lent Rsgpndmdrd rdn nrhnsRy Rn ItIQdsY 1A rl t le4ft. "ww%Mk% nr dn!rtrr.iv dder.M161, sy s11h1roroitYfrsMhndhhllD.MnW Is, tins les4(rp.p!,1h m([ep s;mud r r(N.(rEech wNOW first trbrdr I rrprebf.y Wdry I'Mdn{edars pri.0 0Mco rkr tlttr!h, W. Mi. 1 rwpmrgar lownsp rows. uaeltry Anthony T. Tornbo 111, P E. IInrdintrn!h!yl 4ylnfmr!ddnd4Arn.40r irEo6mntde>:f.rYl IO gvp!r,YndrndsaQl,WRtdhbdl Ygrdrd(FI l!r(r!uldo!fWdo.hellnrdWtme.idyl fi}wr!,nhM dk!utsY YYm(" W a 80083 rYI.Ia1 Orspu d frx:rgi. li n sn!n. d IAD r rSr pmrr N NVols d M 4dR!t (rysrra Sd!q l>S rra [<61J rWJd h RI d Sttl ar rdnu/ h tr rd Ala.. fit 5 t 4 rrstr drmr r rnn d4 has huio, tins RrQ [qr. i tins 4N!Enu, aksr ne. uedndl(e(!rue edq!!o.myltat n dra mt.0Drop l4!mhlei e!r.x.t6ny.,nlm!stm.(Tursenq y mmsiad.!!n(cwbmL 4451 St. Lucie Blvd. 1ptiipit01616AIloci hosses•AmiaoyI. Tomb@ III, p.l.trprododiouhAir dom errs,ioulIwo, ispraiiiitdaitie.ttit writteopermissioobe. Adtooflr.sses-Awlsoatl.Incite, 1ILL1. Fort Pierce, FL 34946 Job Truss Truss Type Qty Ply RYAN HOMES / SEAGATE V4 A0182868 WFCSG4DB VM2 Valley 1 1 Job Reference (optional) Al Roof Trusses, Fort Pierce, FL 34946, design@altruss.com Run: 8.120 s Nov 12 2017 Print: 8.120 s Nov 12 2017 MiTek Industries, Inc. Mon Dec 11 11:35:46 2017 Page 1 I D: UumEB PzQXokuwJ2P5W?E2TyuP 1 h-cAM87S 1 MRt7DTcrUZRQQmnWXEmm?6iE REyQSZJyA3U R 2-0-0 2-M LOADING(psf) SPACING- 2-M CSI. TCLL 20.0 Plate Grip DOL 1.25 TC 0.03 TCDL 10.0 Lumber DOL 1.25 BC 0.02 BCLL 0.0 Rep Stress Incr YES WB 0.00 BCDL 10.0 Code FBC2017/TPI2014 Matrix-P LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 BRACING - TOP CHORD Structural wood sheathing directly applied or 2-0-0 oc puriins. BOT CHORD Rigid ceiling directly applied or 10-M oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation quide. REACTIONS. (lb/size) 1 = 50/2-0-0 (min.0-1-8) 2 = 37/2-0-0 (min.0-1-8) 3 = 12/2-0-0 (min.0-1-8) Max Horz 1 = 26(LC 12) Max Uplift 1 = 12(LC 12) 2 = 29(LC 12) Max Grav 1 = 50(LC 1) 2 = 37(LC 1) 3 = 25(LC 3) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=150mph (3-second gust) Vasd=116mph; TCDL=S.Opsf; BCDL=S.Opsf; h=25ft; Cat. II; Exp C; End., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Plates checked for a plus or minus 0 degree rotation about its center. 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-M wide will fit between the bottom chord and any other members. 2x4 5.00 12 DEFL. in (loc) I/de0 L/d PLATES GRIP Vert(LL) n/a n/a 999 MT20 244/190 Vert(CT) n/a n/a 999 Horz(CT) -0.00 2 n/a n/a Weight: 5 lb FT = 0% 6) Bearing at joint(s) 2 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 2. LOAD CASE(S) Standard t0. 4•n,w0."*1-.d'ulw9TOWrWInrtuulTroet MOTORS RMSrtkMr)uo3nrad<1rIv. r.r.wlo,rrrr m,Imra,yo-..y ra Llw or[Idum*ur.weavdrawmar wPLmh, wrN— dmr-ll--rwb-Im.s.ndA 1,.i-ab}p..A-o It•1d.ud wtrcfonu.cn>udS-I-Mr.,nr+wrrydr.un aNcr.rle.n,d inI hh nv.Y YM1IuW I din Anthony T. Tombo 111, P.E. rmdas, h.,higbwgIlanywslAqdO.Om'rO.r'Iwoerd .,Nro.4Y htQr..b'M.mlitas¢lr4hid OEour aIM.hgmddrlYrgWnid M.d.iyrrld..p,.ar.rtgmarnr.agN :80083 e-bdfgkyn rl-r.r L.r id w.4iNrYr.nndp Iwd61d/glgw+4dd. YYec '.t iQrY,Y14111 rS1(In idr iNY1 nd piu nFi rlw dn:rmun.rw dnu.uby., h.0 hux ry artm r.d e..,.4u 4451 St. Lucie Blvd. An•G M4Ny-fdstgd w.•-1Y I. Qph-IMN hhnf hs*f7.-nbIIIMIry h.p.wi-n1f.IM [4--e dw}W.1. 1/u.YUN trnnn4M.1111. FOIL Pierce, FL 34946 Fr-ipMUtIIAA-Ihdhnul Actbryl.lemA.liLL1. I. F-d.niu.lfAmm isd..I,iugl.tm,isplAJitdo'diraltic-IM"Fames-..h.mAlt..11nanh .A...yl.Tomball],1.1. Job Truss Truss Type Qty Ply RYAN HOMES / SEAGATE v4 WRCSG4D9 VM4 Valley 1 1 A0182869 Job Reference (optional) Al Roof Trusses, Fort Pierce, FL 34946. design@artruss.com g 2x4 i Run: m izu s Nov 1z zul r Pnnt: tt.1Zu S NOV 1Z ZUl / MI IeK mOUstnes, Inc. Mon Dec 11 11f35:47 2017 Pag@ 1 I D:agpjYE3xuP8oBil H6PrSYazz2of-4MwXDo l_CAF34mQg68xfJ_3fL96Ur9UaTc9f5AyA3UQ 4-0-0 4-0-0 1.5x4 II 3x6 11 LOADING (psf) SPACING- 2-" CSI. DEFL. in (loc) I/defl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.20 Vert(LL) n/a n/a 999 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.06 Vert(CT) n/a n/a 999 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(CT) 0.00 3 n/a n/a BCDL 10.0 Code FBC2017/TP12014 Matrix-P Weight: 12 lb FT = 0% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied or 4-0-0 Oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-M oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 1 = 88/4-0-0 (min.0-1-8) 3 = 74/4-0-0 (min. 0-1-8) 5 = 273/4-0-0 (min.0-1-8) 4 = 27/4-0-0 (min.0-1-8) Max Horz 1 = 66(LC 12) Max Uplift 1 = 13(LC 12) 3 = 74(LC 1) 5 = 123(LC 12) 4 = 54(LC 3) Max Grav 1 = 88(LC 1) 3 = 58(LC 12) 5 = 273(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-5=-217/579 NOTES- 1) Wind: ASCE 7-10; Vult=150mph (3-second gust) Vasd=116mph; TCDL=5.Opsf; BCDL=5.Opsf; h=25ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (envelope) and C-C Comer(3) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Plates checked for a plus or minus 0 degree rotation about its center. 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrenl with any other live loads. 5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Bearing at joint(s) 3 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verity capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3, 4 except at --lb) 5=123. LOAD CASE(S) Standard Yoq Mu4rwdlrwN.4'Il ICUI IIOSS(STStlltrl ptWtlNot(01DIIpeS(OSiCY ('M(fj t([t0/t[DHlrtr 4e Phil ptq ryenwf elyd Wtt.411rn143q tro-v{jl0Clw4tdhll.Irek lLOF.IdewtlJrn Mer nt Wt10e.. V&i r kr nt W! Wld ueedr llmr dJ k.u1k 4103uhriltrrlrnrA lyeenpr-Srreu'ifel4rwr.q@]nFrun arrkw d4 rrrkued gernq nyrr07nk MYdl.dw dqh MrlylaDew MICi W., dnIM1I. Ik 4rrp nvgya, t4 ar w,leeYrt Anthony T. Torllbo III, D.E. W. d4r lwr 4gAWln4nywd1q den 0m440-'r eWad qwe M LA* Im.. M IMAI MIFL40,(r4 kd hWq MwIN 14 grnrd 4lpl ee eq lrtl nrdM lnx, edeq Mel trr[r.nWtra ralkq tldlN4rty ejLA1* n4efg0,. pW(MM temrwwerwINW&Mnmrdl.6Wd41c 8lfeepwlMrtlesaXA*0dlllAedWIn &m,41.{ewdldeer rM1lMar4nu+Atdnwhwd4lrnrdup,LwDnpheewdfmrYedrCee,.kn = 80083 4451 St. Lucre Blvd. ree•Fx k4rlhr(dq dal qe •.r hgreen whd Ik Lnr ksl Fgwrng141eW14e a.irnr4;dn fyw doh dlg4Ud krnnnlded•011 Fort Pierce, FL 34946 GpilipM01p16Llddhnut ttlleeyLleeJe l, lE. tepmbniudwsleaertel,ieeltoo, hpmkikilde8keelEke nrtlnpaniuieehow 4d4ollrnurAtlhgl.lotke(11,f.E. Job Truss Truss Type Qty Ply RYAN HOMES / SEAGATE v4 A0182870 WRCS1Q4D9 VM6 Valley 1 1 Job Reference (optional) At Roof Trusses, Fort Pierce, FL 34946, design@altruss com Run: 8.120 s Nov 12 2017 Print: 8.120 s Nov 12 2017 MiTek Industries, Inc. Mon Dec 11 11:35:48 2017 Page 1 I D:agpjYE3xuP8oBil H6PrSYazz2of-YYUvQ82czU NYAw?sgsSusCbfoZNdabkjiGvCdCyA3U P 6-0-0 , 6-0-0 1.5x4 II 2 3 2x4 1.5x4 II LOADING (psf) SPACING- 2-M CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.92 Vert(LL) n/a n/a 999 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.33 Vert(CT) n/a n/a 999 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(CT) 0.00 n/a n/a BCDL 10.0 Code FBC2017/TPI2014 Matrix-P Weight: 20 lb FT = 0% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No-3 BRACING - TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc puriins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation uide. REACTIONS. (lb/size) 1 = 204/6-" (min.0-1-8) 3 = 204/6-" (min.0-1-8) Max Horz 1 = 103(LC 12) Max Uplift 1 = 51(LC 12) 3 = 94(LC 12) Max Grav 1 = 204(LC 1) 3 = 204(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-162/333 NOTES- 1) Wind: ASCE 7-10; VuIt=150mph (3-second gust) Vasd=116mph; TCDL=S.Opsf; BCDL=S.Opsf; h=25ft; Cat. 11; Exp C; End., GCpi=0.18; MWFRS (envelope) and C-C Comer(3) 0-9-1 to 3-9-1, Exterior(2) 3-9-1 to 5-10-4 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Plates checked for a plus or minus 0 degree rotation about its center. 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to beanng plate capable of withstanding 100 lb uplift at joint(s) 1, 3. LOAD CASE(S) Standard m.nm.o..din.trul4lnnusf(1(tuulPwrc6,umn(MCI I'MrIjIiuUMANrl..r.rra,pI lb Utr1krim—WuonmrudrMllksh, WldordiY, ad h.w In tr Ina It a h.lm,ln}hrnpr-l d G¢)4 mlrglinnuefmcgrfu tr Alnttr/rpnlmlmilA Yi rmNinmN YEN 1.,Y,dmYI'J.I., dnlhl, hhsip—afatl lrti uEfrti trlin Anthony T. Tombo 111, P.E. t 80083 dge nlTilrun,6n*t nl,nttrl.ugh,.,.nn,s.m.ter.a.lw4uvauwmm.,.,.,ri..tlrl. 4515t Lu3lvd. Anal. adhnr,. rydpate—nd Fort Pierce, FFL L 34946 6ppio6169t016A-1 tool h.ises Ae16.q LIea6. iIL 1.L Iryfo rd.n. all llis der.mral, in ay form, isp,o6i6ild n 6ael the r0e. pemswm Its. A l lal banes A.lharl.lmh .111,r.1. JANUARY 17, 2017 TYPICAL HIP / KING JACK CONNECTION I STDTL01 A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772-409-1010 CORNERSET GENERAL SPECIFICATIONS MAX LOAD: 55 psf Roof Load, 175 mph, ASCE 7-10, Exp. B, C up to 60' Mean Roof Height and Exposure D up to 30' Mean Roof Height. Attach End Jack's w/ (4) 16d Toe Nails @ TC 3) 16d Toe Nails @ BC Attach King Jack w/ (3) 16d Toe Nails @ TC & 24" Strap w/ (6) 10d x 1.5" ea. end @ BC 0 ttach Corner Jack's r/ (2) 16d Toe Nails @ TC & BC (Typ) Attach Corner Jack's w/ (2) 16d Toe Nails @ TC & BC (Typ) i..,,•n.0 lrr*IIrt..•b'f[17'7[II/r[,q(YI(Iln 0lil11 filYll(Cip7L15 (1:f0.1RfI l;uOc;IK.I}p W. fahktpr. ndid. —Us., elm" l fl bi.artke b..ry r rn rn.,,. rw.brll. rf ufelura ,tlisn.fihr Ys// ttrl:ru rur tgrsb r.4 W MMw+h[,rrr„m.rt:,rn b entr..r.•grty.>tuc,rrryr rt:rr,.ur,ae.r e r,..d nu. nrvrm.pe r+q ue.twwn rruolr,itn,rn 11 y i. loml Ill, P.E. ri'l YrrlryNlq YrrD+e.bO.r,i.e.nl gr.MNegrusn.s Ntskn b Y.,baldb`ilf.lbgtrYdlM.[Y OIs.d.bUde; MYaf Ylmi CrbllaVgtYQ,.R7YdYuy tYYYbirtrredll stifw83 b f/I kcp.dl}e.i Aims temew mod" 01%ls "' MlntM11 ri4 fegMlM Wtp.(if fkWr11r 1lldy(e nrEfr,ssr Pee pdeb [M1I6!if4rt rriktr,dWr}/b lfnr leq.., iro 7m}ltpm dAnlYepan sY51 A451 St lucle Blvd. rtr-rm hr+l l.r(rn bra gw.nygifnn ednl In r.n I'm 1q.n n Cl brigr, ...[m,f Vvoiq n/n Mq ggdiz:Irnnned.r. (IfI Fat Pierce. cl Blvd. OrytiehONlIAdledhnurlf3e.l1.hci*19,11. bprdeoiso41Woiw.eu,iYa,fora hrYkiii,d.nite( rig wines Ind,wfbee A-1WIote}•4cileY,1.I 1U.M. FEBRUARY 17, 2017 1 ALTERNATE GABLE END BRACING DETAIL 1 STDTL03 A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772409-1010 ALTERNATE DIAGONAL BRACING TO THE BOTTOM CHORD I' - 3' MAX. DIAG. BRACE AT 1/3 POINTS IF NEEDED IT IS THE RESPONSIBILITY OF THE BLDG. DESIGNER OR THE PROJECT ENGINEER/ARCHITECT TO DESIGN THE CEILING DIAPHRAGM AND ITS ATTACHMENT TO THE TRUSSES TO RESIST ALL OUT OF PLANE LOADS THAT MAY RESULT FROM THE BRACING OF THE GABLE ENDS. HORIZONTAL BRACE SEE SECTION A -A) TRUSSSES e 24' O.C. 2X6 DIAGONAL BRACE SPACED 4B' O.C. ATTACHED TO VERTICAL WITH 4) - 16d NAILS, AND ATTACHED TO BLOCKING WITH (5) - 10d COMMONS. NAIL DIAGONAL BRACE TO PURLIN WITH TWO 16d NAILS. 2X4 PURLIN FASTENED TO FOUR TRUSSES WITH (2) - 16d NAILS EACH. FASTEN PURLIN TO BLOCKING W/ (2) - 16d NAILS (MIN.). PROVIDE 2X4 BLOCKING BETWEEN THE TRUSSES SUPPORTING THE BRACE AND THE TWO TRUSSES ON EITHER SIDE AS NOTED. TOENAIL BLOCKING TO TRUSSES WITH (2) - 10d NAILS AT EACH END. ATTACH DIAGONAL BRACE TO BLOCKING WITH 5) - 10d COMMON WIRE NAILS. END WALL CEILING SHEATHING BRACING REQUIREMENTS FOR STRUCTURAL GABLE TRUSSES STRUCTURAL GABLE TRUSSES MAY BE BRACED AS NOTED: METHOD 1: ATTACH A MATCHING GABLE TRUSS TO THE INSIDE FACE OF THE STRUCTURAL GABLE AND FASTEN PER THE FOLLOWING NAIL SCHEDULE. METHOD 2: ATTACH 2X_ SCABS TO THE FACE OF EACH VERTICAL MEMBER ON THE STRUCTURAL GABLE PER THE FOLLOWING NAILING SCHEDULE. SCABS ARE TO BE OF THE SAME SCAB ALONGSIZE, GRADE, AND SPECIES AS THE TRUSS VERTICALS. VERTICALNAILINGSCHEDULE: FOR WIND SPEEDS 120 MPH (ASCE 7-9B, 02, 05), 150 MPH (ASCE 7-10) OR LESS, NAIL ALL MEMBERS WITH ONE ROW OF 10d (.131' X 3') NAILS SPACED 6' O.C. FOR WIND SPEEDS GREATER 120 MPH (ASCE 7-98, 02, 05), 150 MPH (ASCE 7-10) NAIL ALL MEMBERS WITH TWO ROWS OF 10d 131'X3') NAILS SPACED 6' Or.(2X4 STUDS MINIMUM). STRUCTURAL GABLE TRUS! MAXIMUM STUD LENGTHS ARE LISTED ON PAGE 1. ALI BRACING METHODS SHOWN ON PAGE I ARE VALID AND ARE TO BE FASTENED TO THE SCABS OR VERTICAL STUDS OF THE STANDARD GABLE TRUSS ON THE INTERIOR SIDE OF THE STRUCTURE. NOTE: THIS DETAIL IS TO BE USED ONLY FOR STRUCTURAL GABLES WITH INLAYED / STUDS. TRUSSES WITHOUT INLAYED S ARE NOT ADDRESSED HERE. / STANDARD GABLE / TRUSS / UKAL TRUSS Ti R1 AN ADEQUATE DIAPHRAGM OR OTHER METHOD OF BRACING MUST BE PRESENT TO PROVIDE FULL LATERAL SUPPORT OF THE BOTTOM CHORD TO RESIST ALL OUT OF PLANE LOADS. THE BRACING SHOWN IN THIS DETAIL IS FOR VERTICAL/STUDS ONLY. STANDARD PIGGYBACK TRUSS DULY 17, 2017 STDTL04 CONNECTION DETAIL THIS DETAIL IS APPLICABLE FOR THE FOLLOWING WIND CONDITIONS: ASCE 7-98, ASCE 7-02, ASCE 7-05, ASCE 7-10 WIND STANDARDS UNDER ALL ENCLOSURE AND EXPOSURE CONDITIONS AS LONG AS NO UPLIFT EXCEEDS 377 LBS. REFER TO ACTUAL PIGGYBACK TRUSS DESIGN DRAWING FOR UPLIFTS. NOTE: THIS DETAIL IS VALID FOR ONE PLY TRUSSES SPACED 24- O.0 OR LESS. A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772-409-1010 PIGGYBACK TRUSS REFER TO ACTUAL TRUSS DESIGN DRAWING FOR ADDITIONAL PIGGYBACK TRUSS INFORMATION. SPACE PURLINS ACCORDING TO THE MAXIMUM SPACING ON THE TOP CHORD OF THE BASE TRUSS SPACING NOT TO EXCEED 24' D.C.) A PURLIN TO BE LOCATED AT EACH BASE TRUSS JOINT. ATTACH PIGGYBACK TRUSS TO THE BASE TRUSS WITH 2' X 8' TEE -LOCK MULTI -USE CONNECTION PLATES SPACED 48' O.C. PLATES SHALL BE PRESSED INTO THE PIGGYBACK TRUSS AT 48' O.C. STAGGERED FROM EACH FACE AND NAILED TO THE BASE TRUSS WITH FOUR (4) 6d (1.5- X 0.099-) NAILS IN EACH PLATE TO ACHIEVE A MAXIMUM UPLIFT CAPACITY OF 377 LBS. AT EACH 2' X 8' TEE -LOCK MULTI -USE CONNECTION PLATE. (MINIMUM OF 2 PLATES) ATTACH EACH PURLIN TO THE TOP CHORD OF THE BASE TRUSS PURLINS AND CONNECTION BY OTHERS) BASE TRUSS REFER TO ACTUAL TRUSS DESIGN DRAWING FOR ADDITIONAL BASE TRUSS INFORMATION. ne,n.rs/,rtw.b'u1 llaus w¢r}onulm srroronnHtKwr(trtriuoarirmrra r r4.on. r,rrl .r ua,trr.ItMwibls i.Mf.1t WmIlknM4r.v.6,ndnuur/.bIID..1 biJ,.Wb 001/dh"abbrp.11 nil 11,IM,trM(atre(i 1-1N7[II jrr+,,,}bNiw IAIN r,,N rter,/bF/IWr/,y,wqu'r.ulApYb Y./bu{,b,gtrpd.bmM,,.tr, ml 14try,l,ykf1(iu(tr1[a, u,a//ll wp , u/enfmlWn.IJk,ubinHW!!i/rOnn,bOm1,.Wq,/.hWYy01c,.bodndb0(,bQ(.IM a11.J7 uhHfM1LO,,//bllEd.INiNI6lnnaAlyhCglryL.tdlo lYoyadlhbi,VrtkY1/ Anthony ll,D.E. trp.mtma.. 01w me W. elq.1,/w.b eLtldrtr(l.1.1/Q ren,1(V}r/.0d 4 IM1. W N.m*mmM lo.i rim IN r6r11r n•.r1rL n.1 641/b l.ntr j 8 83 c..n,W-weyllraT/ar.ngll l.a,mhdA6.utrpte^.nr:ibl.Y Apr,.1m1 p.,Fmtrallfp,nmMtOedsv..I,n 44515t Luck Blvd. ga.t.r./e> tr/Aq n pA era,.enw.e.ml Fort Pletce, FL 34946 ryylit;10191YAIWILnuf lu3atLfubl4t.1. fepoldASI n/m.rnaatMa,opr6lmti.datiOrwmniucilirbmA•]ledhews.Ad.ryl.lwtsIII,fi JULY 17, 2017 1 TRUSSED VALLEY SET DETAIL - SHEATHED I STDTL05 er_ A-1 ROOF TRUSSES 44°4 cr 1 urlc 01 vn FOF SECURE VALLEY TRUSS W/ ONE ROW OF 10d NAILS 6' O.C. ATTACH 2X4 CONTINUOUS #2 SYP TO THE ROOF W/ TWO USP WS45 (1/4- X 4.5-) WOOD SCREWS INTO EACH BASE TRUSS. DETAIL A GENERAL SPECIFICATIONS: 1. NAIL SIZE = 3' X 0.131' = 10d 2. WOOD SCREW = 4.5' WS45 USP OR EQUIVALENT. 3. INSTALL SHEATHING TO TOP CHORD OF BASE TRUSSES. 4. INSTALL VALLEY TRUSSES (24- O.C. MAXIMUM) AND SECURE TO BASE TRUSSES AS PER DETAIL'A'. 5. BRACE VALLEY WEBS IN ACCORDANCE WITH THE INDIVIDUAL DESIGN DRAWINGS. 6. NAILING DONE PER NDS - 01. 7. VALLEY STUD SPACING NOT TO EXCEED 48.O.C. E END, COMMON 3S, OR GIRDER TRUSS TRUSS CRITERIA: WIND DESIGN PER ASCE 7-98. ASCE 7-02, ASCE 7-05: 146 MPH WIND DESIGN PER ASCE 7-10: 170 MPH MAX MEAN ROOF HEIGHT = 30 FEET ROOF PITCH = MINIMUM 3/12 MAXIMUM 6/12 CATERGORY II BUILDING EXPOSURE C WIND DURATION OF LOAD INCREASE: 1.60 MAX TOP CHORD TOTAL LOAD = 50 PSF MAX SPACING = 24.O.C. (BASE AND VALLEY) MINIMUM REDUCED DEAD LOAD OF 6 PSF ON THE TRUSSES. n.a n.,,mr.yy....b•rauofn sstti l[r amuflFrsuoanr,cusn.ftrae,cwe:eauerr. e.yr.,rr..m,.b,u,,,k,4r..yl rrrf.,.11 l.rirtu:•,.rlrnee.0 r,,..Nucce.bno,.w fL d,latle.,,rtr mebbttowr nll netaftFngfgr. (., ir lyw.Abe.rJ..!IFOe¢!u/1.tl,.r.r hIW.d FPnign:rJ4rib4y1rllrf.eLn{irF.M.M1Y.if,eY lM1l, fL pV'n,sef..i Mdl debl,,.rtr1 Anthony T. Tombo ill, P.E. I dagas Tmb rt,Wwhbrrym+r.0"wamye.btnkyk9r...mmWdbm.bedbhWWhg1wrrnf80083 klanksmdGeu no" saw.kfAdb'/3ndrkWnibbon U.P wsdrfM1don kmp.AlWsdesesiblm,kgef.4ns"tgondinsbshfrn,.lr,s 4451 St. Lucie Blvd. s.•.eh.ld,dgedq..n[ ghdr.Moi.d Ikt.,,Mql,pennellkt.M k.a..Fnsfy,a.tymnMeq+t FnrNil.^.1fn,.,mkif.mt Fat Pierce, FL 34946 Gppitlrm}016AIfodlmsn Am6oTl.lee6eol,li. Fe/ndeoiuef6isdufinem,inmykm,6vskifiled.kbalthesi,nnpemninhim AlRoof hesses-AadoryLbod.III, l.l. JULY 17, 2017 1 TRUSSED VALLEY SET DETAIL I STDTL06 GENERAL SPECIFICATIONS: 1. NAIL SIZE = 3' X 0.131' = 10d 2. WOOD SCREW = 3' WS3 USP OR EQUIVALENT. 3. INSTALL VALLEY TRUSSES (24- O.0 MAXIMUM) AND SECURE PER DETAIL A'. 4. BRACE VALLEY WEBS IN ACCORDANCE WITH THE INDIVIUAL DESIGN DRAWINGS. 5. BASE TRUSS SHALL BE DESIGNED WITH A PURLIN SPACING EQUIVALENT TO THE RAKE DIMENSION OF THE VALLEY TRUSS SPACING. A-1 ROOF TRUSSES 6. NAILING DONE PER NDS - 01. 4451 ST. LUCIE BLVD. GABLE END, COMMON 7. VALLEY STUD SPACING NOT TO EXCEED 48' O.C. FORT PIERCE, FL 34946 TRUSS, OR GIRDER 772-409-1010 TRUSS SECURI W/( VALLEY TRUSS —v II II II II II BASE TRi SSES TYPICAL) NO SHEATHING) N.T.S. GABLE END, COMMON TRUSS, OR GIRDER P F-1 2 VALLEY TRUSS TRUSS TYPICAL) SEE DETAIL'A' BELOW (TYP.) WIND DESIGN PER ASCE 7-98, ASCE 7-02, ASCE 7-05: 146 MPH WIND DESIGN PER ASCE 7-10: 170 MPH MAX MEAN ROOF HEIGHT = 30 FEET ROOF PITCH = MINIMUM 3/12 MAXIMUM 6/12 CATERGORY II BUILDING EXPOSURE WIND DURATION OF LOAD INCREASE: 1.60 ATTACH 2X4 CONTINUOUS #2 MAX TOP CHORD TOTAL LOAD = 50 PSF SYP TO THE ROOF W/ TWO USP MAX SPACING = 24' O.C. (BASE AND VALLEY) WS3 (1/4- X 3-) WOOD SCREWS MINIMUM REDUCED DEAD LOAD OF 6 PSF ON THE TRUSSES. INTO EACH BASE TRUSS n• .,YnOCT it14mTmtte'}almTills e(o.mr.stesta (-%rrlu00vr"erti T h4gr•n.v,r,drnwr,kmhr &-4jibhrwub. T,1I..rnlI Urmtk.bV1 r , biJ,w,t• r lbl. ,fr N,NI I. •, f01•I.,w1 I,.Im. hur 6,u lr1, INdN tyMS M.9.. M,wrw..'p../v Fi,.w*r..1,r.uW Y 6, iq d6yL G,Y fiedw 0- A1W,". A! T.fips— n a u. Anthony T. Tombo III, P.E. r.u r.tu„w.tt.iquyuydutara.a,,rc.w'„r.cNe vdwrko,cre.•e„ru,brut,e.rcr,ttdwu„ ,rtnt.lbonsi tetmlwmbm gwIn rwyery my,.rp•.r.c,.t,.filue,,,ur,r, a 80083 NL.II AfrorlY• 9,-l1.glfOM.YIArMl1(k,frMllWn<ril'J U•rMf tf.e)Y4,W.,uvl W,r nseruu rakn,dt,+.0 mtea.,rnu.ti+•,.rw.en i.,.eur•w•s,k.r5t+woet,m..u.wu "515t Lucie Blvd. u..,ua .eh, t.e,r,r..wyprr.r,ennw dn.nd,*bow.•.;I,vw.twr.,.t.uqu,.t.p..r4w«, ttyru+,r.,.,.re.t.nu Fort Pierce, FL 34946 foprg1fO111 A II• elGnu.•letkwk Llnb N, LI. iepduun•t ibis(msed is in him, op•Aftd.ak•ek tbe.,iotyerrhim kin Red h•sses-$zk,q 1. Itak• 61./.E. JULY 17, 2017 1 1VY'%LLL_ 1 %.?L- HIGH WIND VELOCITY) STDTL07 A- 1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772409- 1010 ATTA( WIND DESIGN PER ASCE 7-98, ASCE 7 WIND DESIGN PER ASCE 7-10: 170 MPI MAX MEAN ROOF HEIGHT = 30 FEET CATERGORY II BUILDING EXPOSURE B OR C WIND DURATION OF LOAD INCREASE: MAX TOP CHORD TOTAL LOAD = 50 PSI MAX SPACING = 24' O.C. (BASE AND VA OUrrUR 1 IN%L 1R00000 U1Mr%-I LT UNUCR VHLLCT IRUOOC.I. MUO1 OC DESIGNED WITH A MAXIMUM UNBRACED LENGTH OF 2' - 10' ON AFFECTED TOP CHORDS. NOTES: 1. SHEATHING APPLIED AFTER INSTALLATION OF VALLEY TRUSSES. 2. THIS DETAIL IS NOT APPLICABLE FOR SPF-S SPECIES LUMBER. FOR BEVELED BOTTOM CHORD, CLIP MAY BE APPLIED TO EITHER FACE. CLIP MAY BE APPLIED I TO THIS FACE UP TO ANON -BEVELEDMAXIMUM6/12 PITCH NON -BEVELED BOTTOM CHORD BOTTOM CHORD o CLIP MUST BE APPLIED TO THIS FACE WHEN PITCH EXCEEDS 6/12 (MAXIMUM 12/ 12 PITCH) a. rrtrr.rµrna.r•oftI]tJlItrtlsIZRt[ry4.rotnlwfccm.roKI nc,fnmrlunoluwlurr. Task "sonUnofferwe aToss hap b.g6MIrrrdnI hrr111FI femrshellbe.m W A.—and.Ir111,.q WWr V. 1,Yrnrlr Arftl. r.rl lrrMlburt.npr, l xA,l.y+w;d uduu,idlgrvm.argl.rl r Fblrwdepur7ny.di rh+p raa uf. hrq J arJ.r dr,.rl rra mrap nvyrr.,ua,owo,ulxain Androny T. Tombo Ill, P.E. rrnrl.nirmr.! WlyornyrWgdk0-n.dy111#1kwin,y.,.rlEwdaot.rucetrarge.:.urrrmgmaranw+e:>,I r800S3 rwarua4orhmu urwlsaw rmratmm'srp* lrj411*bWWWSde WruwKgptlkiNMWWJnran;erpW*pKLD1Ii .rarepzswcrwrartauMIup ,Imkupt"lnrtmi4.m.n,den 4451 St. Lucie Blvd. k+.r dylc.+ei...haser. ra rrMltiwlell(m1r ,.4 nSnnL um yhJby f1aHSYnikmoreL ad.RF1 Fort Pierce, FL 34946 FEBRUARY 17, 2017 I STANDARD GABLE END DETAIL I STDTLO$ n, A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772-009-1010 TYPICAL 2X4 L-BRACE NAILED TO 2X4 VERTICALS W/IOd NAILS, 6' O.C. V ERT STUD SECTION B-B TRUSS GEOMETRY AND CONDITIONS SHOWN ARE FOR ILLUSTRATION ONLY. DIAGONAL BRACE 4' - 0' O.C. MAX. SEE INDIVIDUAL ENGINEERING DRAWINGS FOR TRUSS DESIGN CRITERIA. v DIAGONAL BRACING icicL - BRACING REFER REFER TO SECTION A -A TO SECTION B-B 24' MAX. NOTE: 1. MINIMUM GRADE OF N2 MATERIAL IN THE TOP AND BOTTOM CHORDS. 2. CONNECTION BETWEEN BOTTOM CHORD OF GABLE END TRUSS AND WALL TO BE PROVIDED BY PROJECT ENGINEER OR ARCHITECT. 3. BRACING SHOWN IS FOR INDIVIDUAL TRUSS ONLY. CONSULT BLDG. ARCHITECT OR ENGINEER FOR TEMPORARY AND PERMANENT BRACING OF ROOF SYSTEM. 4. 'L' BRACES SPECIFIED ARE TO BE FULL LENGTH, SPF OR SP #3 OR BETTER WITH ONE ROW OF 10d NAILS SPACED 6' O.C. 5. DIAGONAL BRACE TO BE APPROXIMATELY 45 DEGREES TO ROOF DIAPHRAGM AT4'-0'D.C. 6. CONSTRUCT HORIZONTAL BRACE CONNECTING A 2X6 AND A 2X4 AS SHOWN WITH 16d NAILS SPACED 6' D.C. HORIZONTAL BRACE TO BE LOCATED AT THE MIOSPAN OF THE LONGEST GABLE STUD. ATTACH TO VERTICAL GABLE STUDS WITH (3) IOd NAILS THROUGH 2X4 (REFER TO SECTION A -A) EEEDS 1/240 VERTICAL 2X6 SP OR SPF STUDVBRACE 2 DIAGONAL BRACE 4) - 16d NAILS16d NAILS SPACED 6' D.C. 2) 10d NAILS INTO 2X62X6 SP OR SPF #2 2X4 SP ORORLSPF HORIZONTAL NAILED TO ERTICALS SECTION A -A V/(4) - 10d NAILS PROVIDE 2X4 BLOCKING BETWEEN THE FIRST TWO TRUSSES AS NOTED. TOENAIL BLOCKING TO TRUSSES WITH (2) - IDd NAILS AT EACH END. ATTACH DIAGONAL BRACE TO BLOCKING WITH (5) - 10d NAILS 4) Bd NAILS MINIMUM, PLYWOOD SHEATHING TO 2X4 STD SPF BLOCK 12' MAX. 1. GABLE STUD DEFLECTION MEETS OR EXC DIAG. BRACE B. THIS DETAIL DOES NOT APPLY TO STRUCTURAL GABLES. AT 1/3 POINTS 9. DO NOT USE FLAT BOTTOM CHORD GABLES NEXT TO SCISSOR TYPE IF NEEDED TRUSSES. 10. 10d AND 16d NAILS ARE 0.131'X31r AND 0.131'X3.S' COMMON WIRE NAILS RESPECTIVELY. 11. SOUTHERN PINE LUMBER DESIGN VALUES ARE THOSE EFFECTIVE 06-01-12 BY SPIB/ALSO. MINIMUM STUD SIZE SPECIES AND GRADE STUD SPACING WITHOUT BRACE 2X4 L - BRACE DIAGONAL BRACE 2) DIAGONAL ATBRACES T1/3 POINTS MAXIMUM STUD LENGTH 2X4 SP #31 STUD 12' O.C. 3.8-10 5-6-11 6-6-11 11-1-13 2X4 SP #31 STUD 16' O.C. 3-3-10 4-0-12 6-0i-11 9-10.15 2X4SP#31STUD 24'0.C. 2-8-6 3-11-3 5-4-12 8-1-2 2X4 SP #2 12' O.C. 3.10-15 5-&l 1 6-6-11 11-8-14 2X4 SP #2 16' O.C. 3.6-11 4-9-12 6-&I l 10-8-0 2X4 SP #2 24' O.C. 1 3-14 1 3-11-3 1 6-2.9 9.3-13 DIAGONAL BRACES OVER 6' — 3' REQUIRE A 2X4 T—BRACE ATTACHED TO ONE EDGE. DIAGONAL BRACES OVER 12' — 6' REQUIRE 2X4 I —BRACES ATTACHED TO BOTH EDGES. FASTEN T AND I BRACES TO NARROW EDGE OF DIAGONAL BRACE WITH IOd NAILS 6' O.C., WITH 3' MINIMUM END DISTANCE. BRACE MUST COVER SOX OF DIAGONAL LENGTH. T OR I BRACES MUST BE 2X4 SPF #2 OR SP M2. ROOF SHEATHING VIMFI41 TRUSSES 0 24' O.C. 2X6 DIAGONAL BRACE SPACED 48' O.C. ATTACHED TO VERTICAL WITH (4) - 16d NAILS, AND ATTACHED TO BLOCKING WITH (5) - 10d NAILS. HORIZONTAL BRACE SEE SECTION A -A) END WALL MAX MEAN ROOF HEIGHT = 30 FEET EXPOSURE B OR C ASCE 7.10 190 MPH STUD DESIGN IS BASED ON COMPONENTS AND CLADDING. DURATION OF LOAD INCREASE :1.60 CONNECTION OF BRACING IS BASED ON MWFRS. DETA FEBRt1ARY 17, 2017 I T WITH 2XIBRACE ONLY IL I STDTL09 VOTES: f-BRACING / I -BRACING TO BE USED WHEN CONTINUOUS LATERAL BRACIN( IS IMPRACTICAL. T-BRACE / I -BRACE MUST COVER 90% OF WEB LENGTH. PHIS DETAIL NOT TO BE USED TO CONVERT T-BRACE / I -BRACE WEBS T( ONTINUOUS LATERAL BRACED WEBS. A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD FORT PIERCE. FL 34946 772-409-1010 NAILING PATTERN T-BRACE SIZE NAIL SIZE NAIL SPACING 2X4 OR 2X6 OR 2XB 10d 6' O.C. NOTE NAIL ALONG ENTIRE LENGTH OF T-BRACE / I -BRACE (ON TWO-PLY TRUSSES NAIL TO BOTH PLIES) NAILS SPACING BRACE SIZE FOR ONE -PLY TRUSS SPECIFIED CONTINUOUS ROWS OF LATERAL BRACING WEB SIZE 1 2 2X3 OR 2X4 2X4 T-BRACE 2X4 I -BRACE 2X6 2X6 T-BRACE 2X6 I -BRACE 2X8 2X8 T-BRACE 2X8 I -BRACE BRACE SIZE FOR TWO-PLY TRUSS SPECIFIED CONTINUOUS ROWS OF LATERAL BRACING WEB SIZE 1 2 2X3 OR 2X4 2X4 T-BRACE 2X4 I -BRACE 2X6 2X6 T-BRACE 2X6 I -BRACE 2X8 2X8 T-BRACE 2X8 I -BRACE T-BRACE / I -BRACE MUST BE SAME SPECIES AND GRADE (OR BETTER) AS WEB MEMBER. NAILS WEB NAILS I -BRACE NAILS WEB T-BRACE SECTION DETAILS FEBRUARY 17, 2017 LATERAL BRACING RECOMMENDATIONS I STDTL10 TO MINIMIZE VIBRATION COMMON TO ALL SHALLOW FRAMING SYSTEMS, 2X6 'STRONGBACK' IS RECOMMENDED, LOCATED EVERY B TO 10 FEET ALONG A FLOOR TRUSS. C N 0 T E 1: 2X6 STRONGBACK ORIENTED VERTICALLY MAY BE POSITIONED DIRECTLY UNDER THE TOP CHORD OR DIRECTLY ABOVE THE BOTTOM CHORD, SECURELY FASTENED TO THE TRUSS USING ANY A-1 ROOF TRUSSES OF THE METHODS ILLUSTRATED BELOW. 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 NOTE 2: STRONGBACK BRACING ALSO SATISFIES THE LATERAL BRACING REQUIREMENTS FOR THE 772409-1010 BOTTOM CHORD OF THE TRUSS WHEN IT IS PLACED ON TOP OF THE BOTTOM CHORD, IS CONTINUOUS FROM END TO END, CONNECTED WITH A METHOD OTHER THAN METAL FRAMING ANCHOR, AND PROPERLY CONNECTED, BY OTHERS, AT THE ENDS. INSERT WOOD SCREW THROUGH OUTSIDE FACE OF CHORD INTO EDGE OF STRONGBACK (DO NOT USE METAL FRAMING ATTACH TO VERTICAL ATTACH TO VERTICAL USE DRYWALL TYPE SCREWS) ANCHOR TO ATTACH VEB WITH (3) - IOd SCAB WITH (3) - IOd TO TOP CHORD NAILS (0131' X 3') NAILS (0131' X 3'). r ATTACH TO VERTICAL BWITH LS ) ( 01313X 3 ) NAILSBLOCKING BEHIND THE VERTICAL WEB IS RECOMMENDED WHILE NAILING THE STRONGBACK USE METAL FRAMING - ATTACH TO VERTICAL ANCHOR TO ATTACH WEB WITH (3) - IOd TO BOTTOM CHORD NAILS (0131' X 3') ATTACH 2X4 VERTICAL TO FACE OF TRUSS. FASTEN TO TOP AND BOTTOM CHORD WITH 2) - 10d NAILS (0131' X 3) IN EACH CHORD ATTACH TO VERTICAL SCAB WITH (3) - 10d NAILS ( 0.131' X 3') TRUSS 2X6 4' - WALL STRONGBACK ( TYPICAL SPLICE) (BY OTHERS) ATTACH TO CHORD WITH ( 2) N12 X 3' WO00 SCREWS 0216' OIA1 INSERT SCREW THROUGH OUTSIDE FACE OF CHORD INTO EDGE OF STRONGBACK (DO NOT USE DRYWALL TYPE SCREWS) THE STRONGBACKS SHALL BE SECURED AT THEIR ENDS TO AN ADEQUATE SUPPORT, DESIGNED BY OTHERS. IF SPLICING IS NECESSARY, USE A 4' - 0' LONG SCAB CENTERED ON THE SPLICE AND JOINED WITH (12) - 10d NAILS (0.131' X 3') EQUALLY SPACED. ALTERNATE METHOD OF SPLICING: OVERLAP STRONGBACK MEMBERS A MINIMUM OF 4' - 0' AND FASTEN WITH (12) - 10d NAILS (0131' X 3) STAGGERED AND EQUALLY SPACED (TO BE USED ONLY WHEN STRONGBACK IS NOT ALIGNED WITH A VERTICAL). BLOCKING BY OTHERS) FEBMARY 17, 2017 A•1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE. FL 34946 772409-1010 LATERAL TOE -NAIL DETAIL NOTES: 1. TOE -NAILS SHALL BE DRIVEN AT AN ANGLE OF 45' WITH THE MEMBER AND MUST HAVE FULL WOOD SUPPORT (NAIL MUST BE DRIVEN THROUGH AND EXIT AT THE BACK CORNER OF THE MEMBER END AS SHOWN). 2. THE END DISTANCE, EDGE DISTANCE, AND SPACING OF NAILS SHALL BE SUCH AS TO AVOID UNUSUAL SPLITTING OF THE WOOD. 3. ALLOWABLE VALUE SHALL BE THE LESSER VALUE OF THE TWO SPECIES FOR MEMBERS OF DIFFERENT SPECIES. TOE -NAIL SINGLE SHEAR VALUES PER NOS 2001 (LB/NAIL) DIA SP OF HF SPF SPF-S 131 88.0 80.6 69.9 68.4 59.7 z 135 93.5 85.6 74.2 72.6 63.4 0J 162 108.8 99.6 86.4 84.5 73.8 pi 128 74.2 67.9 58.9 57.6 50.3 0 131 75.9 69.5 60.3 59.0 51.1Z0J in 148 81.4 74.5 64.6 63.2 52.5 N M VALUES SHOWN ARE CAPACITY PER TOE -NAIL. APPLICABLE DURATION OF LOAD INCREASES MAY BE APPLIED. EXAMPLE: 3) - 16d NAILS (0162' DIA. X 35') WITH SPF SPECIES BOTTOM CHORD FOR LOAD DURATION INCREASE OF 115: 3 (NAILS) X 845 (LB/NAIL) X 115 (DOL) = 2915 LB MAXIMUM CAPACITY ANGLE MAY VARY FROM 30' TO 60• 45.00' STDTL11 THIS OETAIL IS ONLY APPLICABLE TO THE THREE END DETAILS SHOWN BELOW. VIEWS SHOWN ARE FOR ILLUSTRATION PURPOSES ONLY. SIDE VIEW 2X3) 2 NAILS NEAR SIDE NEAR SIDE SIDE VIEW 2X4) 3 NAILS NEAR SIDE NEAR SIDE NEAR SIDE 0° SIDE VIEW 2X3) 2 NAILS NEAR SIDE NEAR SIDE NEAR SIDE NEAR SIDE l0° FEBRUARY 17, 2017 UPLIFT TOE -NAIL DETAIL STDTL12 A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FEBRUARY 5, 2016 A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772-409-1010 I.0x4 TYP 2x2 NAILER ATTACHMENT I STDTLI3 2x2 NAILER ATTACHMENT GENERAL SPECIFICATIONS MAX LOAD: 55 psf Roof Load, 170 mph, ASCE 7-10, 29'-0" Mean Height, Exp. B, C or D. April 11, 2016 TYPICAL ALTERNATE BRACING DETAIL FO EXTERIOR FLAT GIRDER TRUSS STDTL 14 A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772-409-1010 4) 12d TRUSS 2411 O.C. UPLIFT CONNECTION SEE ROOF TRUSS) EXTERIOR FLAT GIRDER 12 VARIES 4) 12d MAX 3011 (21-611) 2x6 #2 SP (Both Faces) 24" O.C. SIMPSON H5 r..n•rr,y,mnr•lir:7 nC5IfIVtBr'lHmulu.lr¢W17.4f/{r0•rj grrenllwrt'r• r.h•,•r..•.rnr rr..,rmhn.4•r irq llQrrla.l, Inw rl unr.tw.r... l.l.0 rn.ir,r.rwr ry r; WIN,rwb,Yr.lA Y.YI h wlfo.Y nY r,rhn,Mu/l7wn(.•1,r,l Ir,wjb,M•r11M,g.... .;golwp/nurl rlwnlnyruWlY wly/r u. Ln, Irr alr4fr d1,.4r f41 IA M,*nwr,r,,YY iwta•H) AnthonyT. Torrbo III. G.E. rl.u/btlm,rglil no nyai/r0..r7.,p.uMr.rMY11ry...r.e/rVl.rr(wlrfrd4/rro•w1IM11. M1rrw//6171 r1 w•Mlw/w h.n. r Wh hq rcr• .u.nm..w r7rr m,rr+M/sl+rrl+rr.+s/.A rbrttvlwrNhthrmr..ib..Mr : E0683 r• tl, Mrlbrtrao l„/,.Ir. RI Ye•,rn,rnYb,wl4•n/whm /nww, h.n MCr,wrrr lm, vr. w, w' n :451 $ L CIKIC Blvd. M7r. nr,lrawn,and I.4n,rylr..n10Ir WI•,r,*r,.hw,fr,•r 14rn J., l.+y lc.r•l.rrnanur•Iwl Fort Glence, F! 34946 HI/ b I lul hart • Arhery I. b W 14. 1,l. lep•4niu d di, Awrwra r rry Iww. n prliln:l •i;l.d ae ainr• prwnw hm A I lul Lou, Asrlut I, IrwM 111.11. EERUARY 17, 2017 STANDARD REPAIR DETAIL FOR BROKEN CHORDS, WEBS, AND I STDTL15DAMAGEDORMISSINGCHORDSPLICEPLATES A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE. FL 34946 772409-1010 TOTAL NUMBER OF NAILS EACH SIDE OF BREAK * X INCHES) MAXIMUM FORCE (LBS) 15% LOAD DURATION SP OF SPF HF 2X4 2X6 2X4 2X6 2X4 2X6 2X4 2X6 2X4 2X6 20 30 24' 1706 2559 1561 2342 1320 1980 1352 2028 26 39 30' 2194 3291 2007 3011 1697 2546 1738 2608 32 48 36' 2681 4022 2454 3681 2074 3111 2125 3187 38 57 42" 3169 4754 2900 4350 2451 3677 2511 3767 44 66 48' 3657 5485 3346 5019 2829 4243 2898 4347 DIVIDE EQUALLY FRONT AND BACK ATTACH 2X_ SCAB OF THE SAME SIZE AND GRADE AS THE BROKEN MEMBER TO EACH FACE OF THE TRUSS ( CENTER ON BREAK OR SPLICE) WITH 10d NAILS (TWO ROWS FOR 2X4, THREE ROWS FOR 2X6) SPACED 4' O.C. AS SHOWN (131' DIA. X 3'). STAGGER NAIL SPACING FROM FRONT FACE AND BACK FACE FOR A NET 2' O.C. SPACING IN THE MAIN MEMBER. USE A MIN. 3' MEMBER END DISTANCE. THE LENGTH OF THE BREAK (C) SHALL NOT EXCEED 12'. (C=PLATE LENGTH FOR SPLICE REPAIRS) THE MINIMUM OVERALL SCAB LENGTH REQUIRED (L) IS CALCULATED AS FOLLOWS: L = (2) X + C TRUSS CONFIGURATION AND BREAK LOCATIONS FOR ILLUSTRATIONS ONLY THE LOCATION OF THE BREAK MUST BE GREATER THAN OR EQUAL TO THE REQUIRED X DIMENSION FROM ANY PERIMETER BREAK OR HEEL JOINT AND A MINIMUM OF 6' FROM ANY INTERIOR JOINT (SEE SKETCH ABOVE). DO NOT USE REPAIR FOR JOINT SPLICES NOTES: 1. THIS REPAIR DETAIL IS TO BE USED ONLY FOR THE APPLICATION SHOWN. THIS REPAIR DOES NOT IMPLY THAT THE REMAINING PORTION OF THE TRUSS IS UNDAMAGED. THE ENTIRE TRUSS SHALL BE INSPECTED TO VERIFY THAT NO FURTHER REPAIRS ARE REQUIRED. WHEN THE REQUIRED REPAIRS ARE PROPERLY APPLIED, THE TRUSS WILL BE CAPABLE OF SUPPORTING THE LOADS INDICATED. 2. ALL MEMBERS MUST BE RETURNED TO THEIR ORIGINAL POSITIONS BEFORE APPLYING REPAIR AND HELD IN PLACE DURING APPLICATION OF REPAIR. 3. THE END DISTANCE, EDGE DISTANCE, AND SPACING OF NAILS SHALL BE SUCH AS TO AVOID UNUSUAL SPLITTING OF THE WOOD. 4. WHEN NAILING THE SCABS, THE USE OF A BACKUP WEIGHT IS RECOMMENDED TO AVOID LOOSENING OF THE CONNECTOR PLATES AT THE JOINTS OR SPLICES. S. THIS REPAIR IS TO BE USED FOR SINGLE PLY TRUSSES IN THE 2X_ ORIENTATION ONLY. 6. THIS REPAIR IS LIMITED TO TRUSSES WITH NO MORE THAN THREE BROKEN MEMBERS. FEBRUARY 17, 2017 SCAB APPLIED OVERHANGS I STDTL16 -e A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772-409-1010 TRUSS CRITERIA: LOADING: 40-10-D-10 DURATION FACTOR: 115 SPACING: 24' O.C. TOP CHORD: 2X4 OR 2X6 PITCH: 4/12 - 12/12 HEEL HEIGHT: STANDARD HEEL UP TO 12' ENERGY HEEL END BEARING CONDITION NOTES: 1. ATTACH 2X-SCAB (MINIMUM #2 GRADE SPF, HF, SP, OF) TO ONE FACE OF TRUSS WITH TWO ROWS OF 10d COMMON WIRE NAILS (148' DIA. X 3') SPACED 6' O.C. 2. THE END DISTANCE, EDGE DISTANCE, AND SPACING OF NAILS SHALL BE SUCH AS TO AVOID UNUSUAL SPLITTING OF THE WOOD. 3. WHEN NAILING THE SCABS, THE USE OF A BACKUP WEIGHT IS RECOMMENDED TO AVOID LOOSENING OF THE CONNECTOR PLATES AT THE JOINTS OR SPLICES. 2X SC NOTE: TRUSS BUILT WITHOUT AN OVERHANG. THIS DETAIL IS NOT TO BE USED WHEN OVERHANG HAS BEEN BROKEN OFF. IMPORTANT THIS DETAIL TO BE USED ONLY WITH TRUSSES (SPANS LESS THAN 4D) SPACED 24' O.C. MAXIMUM AND HAVING PITCHES BETWEEN 4/12 AND 12/12 AND TOTAL TOP CHORD LOADS NOT EXCEEDING 50 PSF. TRUSSES NOT FITTING THESE CRITERIA SHOULD BE EXAMINED INDIVIDUALLY. REFER TO INDIVIDUAL TRUSS DESIGN FOR PLATE SIZES AND LUMBER GRADES 1 tr l eD2 ri£;:5'"::n:;:rl.>::*c L.G x4w'<a;'u.*X:?lCLca;;:,`;:!nl::fb:zF laY;£A3"<8;:rw;isi,`'iQ>GY'!i..574A%>•?'Gti>3:A;;+N.d'c GI iP K v 5` F, iia wxxxx-.z a s;c r1i:.e:1lYi:rfir'o'fi?'r,:\'h i vG`>:: HATCH LEGEND 16" RECESS 9- 4` A.F.F. 12'-WAY F Gravity (> 5.0000) / Uplift (> - Horizontal (> 350#) Note: Trusses are designed for SHINGLE material. Notify Truss manufacturer it material t A iM1E'.•D 1,or+0 IIIE90*31T I ;l v0 ROOF tOr• y1y. ••JQT HIP UNE 139. Mwruh t VAUEY UNE 25. S67!AL :: 3aaCA1210000WmCC12a2arl••. - NUI t: ALL MUDS I WALL"' UH IHUJJ IU LEDGER CONNECTIONS BY BUILDER e a r (UNLESS NOTED OTHERWISE) NOTE: ALL CEILING DROPS BELOW BEAM ARE BY BUILDER (UNLESS NOTED OTHERWISE) - NOTE THIS TRUSS PLACEMENT DIAGRAM IS TO ass i SHOW TRUSS I.D. AND TRUSS LOCATION ONLY. THE BUILDING DESIGNER IS REPSONSIBLE FOR THE STRUCTURAL STABILITY OF THE ENTIRE STRUCTURE. = 5 b REFER TO THE INDIVIDUAL TRUSS ENGINEERING DRAWINGS FOR GRAVITY AND UPLIFT LOADS. FOR BRACING 6 ERECTION DETAILS REFER = i L n TO BCSI-03 AND/OR ENGINEER OF RECORD e _ _ a x aa •C S a ^ REPRESENTS THE LEFT SIDE OF = _ EACH TRUSS DRAWING s' s i S s JUS24 I H) THD46 - Z. Se- `9'+_ 8)I JUS26 hill MSH422 c L c - C THD26 Ik K;l MUS26 a_ i 8 a5 _ E OD THD28 EO THD26-2 OF THD28-2 OG 1US48 OO .. 3, a = a. 4 HANGER BY BUILDER - __ r _ _ _ LOADING ROOF FLOOR WIND LOAD : _ ` _ d 0 LIVE LOAD 20 - ASCE 7.10 s 6 C 1 0 0 = E e x p C u DEAD LOAD SO - ISO MPH I EXP C L-E_i ems_ F a LIVE LOAD 10• - CATEGORY II a m 0 DEAD LOAD 10 - ENCLOSED TOTAL LOAD 40 FBC-2017 = e e e F DURATION FACTOR 1.25 - TPI-2014 REV DATE BY REMARKS - >' 1 12/11/17 HPR CODE UPDATE z= It Is understood that above conditions have been reviewed APPROVED e - - d are acceptable for the -X _ fabrication al trusses, APPROVED AS NOTED elevabons,paches, overhangs, REVISE AND RESUBMIT _ . s S. fasaas.ow in9 - c elevatbns/pitches, bearing RE1ECfED ° - - condining itons6alldetailperta' - - - to this truss placement plan. No "e •+ - - L back charges will be accepted = _ - _ c- = e without previous vmhen DATE _ e A approval from an A-1 Roof 8 - - TrD5se5 representative. REVIEWED BY i + ` J. PLAN DATE ARCH: -/--/— STRUCT: CUSTOMER RYAN HOMES c i JOB NAME SEAGATEA'D' e oPT10N( S) 9,4-CfILAYGS COMMNTY LOT LOT 28 - o - : i BLDG _ BLDG TYPE # _ = JOB # 72420 MASTER WRCSG4D9 = E e- = DRAWN SCALE ? _ - E ° a DATE 09/28/2015 R N7.S. j A- 1 ROOF f b: TRU55E5 = = ti _` = E = '• a `. = a A FLORIDA CORPORATION i Ph 772-409-1010 / Fax 772409.1015 zt hVYAvww. alfrusscom — _ 3 CITY OF SANFORD t k BUILDING & FIRE PREVENTION PERMIT APPLICATION a Application No: D ' a514 v') Documented Construction Value: $ 3 V Job Address: Historic District: Yes Nq7' Parcel ID: ResidentiCommercial, Type of Work: New ddition Alteration Repair Demo Change of Use Move El Description of Work: Plumbing New Residential Construction Plan Review Contact Person: Jamie Blackwell Title: Clerical Phone: 407-323-7515 Fax: 407-323-8954 Email: info u a i-orlando.co Property Owner Information Name Kiwi 140W S Phone: ,/ Street: Resident of property? : / 0 City, State Zip: Contractor Information Name Advantage Plumbing, Inc. Phone: 407-323-7515 Street: PO Box 1117 Fax: 407-323-8954 City, State Zip: Sanford, FL 32772 State License No.: CF-0057881 Name: Street: City, St, Zip: Bonding Company: Address: Architect/ Engineer Information Phone: Fax: E- mail: Mortgage Lender: Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: 50 Edition (2014) Florida Building Code Revised: June 30, 2015 Permit Application NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may befoundinthepublicrecordsofthiscounty, and there may be additional permits required from other governmental entities such as watermanagementdistricts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford mqui es payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal. The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value, credit will be applied to your permit fees when the permit is issued. OWNER'S AFFIDAVIT: I certify that all of the foregoing information b accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Signature of Owner/ABA Data Print Owner/Agent's Name Sigoatiae ofNGW3State of Florida pate Owner/ Agent is Personally Known to Me or Produced ID Type of iD Signnme of CamdtactorlAgerrt A. Thomas Smith print Connactor/Agmt's Name p 3gnarcoY- Meredith ftenwk.- mtRi Data NOTARY PUBLIC VC,; STATE OF FLORVA Ca ntil GG136M E) Vres 8,2112021 Contractor/ Agent is X Personally Known to Me or Produced ID Type of 11) BELOW IS FOR OFFICE USE ONLY Permits Required: Building Electrical Mechanical D Plumbing Gag Roof Construction Type: Total Sq Ft of Bldg: Occupancy Use: Flood Zone: Min. Occupancy Load: # of Storles: New Construction: Electric - # of Amps Plumbing - # of Fixtures Fire Sprinkler Permit: Yes No # of Heads Fire Alarm Permit: Yes No El APPROVALS: ZONING: ENGINEERING: COMMENTS: UTILITIES: FIRE: WASTE WATER: BUILDING: Revised: June 30. 2015 Permit Application or CITY OF SANFORD BUILDING & FIRE PREVENTION PERMIT APPLICATION Application No: 18 - 954 Documented Construction Value: $ _ t4D ` b Job Address: 3733 Qr ,r-}-{-, Historic District: Yes No Parcel ID: Residential Commercial Type of Work: I\'eW14 Addition Alteration Repair Demo Change of Use Move Description of Work: I ,t k ) I !"TI—) n r-, , A . C":,o t t , r• n Plan Review Contact Person: Phone: Fax: Email: Property Owner Information Title: Name (,i ,s Phone: — ( Street: (1-7HM77Resident of property? : 7 City, State Zip: 3asj r Contractor Information Name al rnp ec h-It A r 11 rr'' Phone: %-1-(7 Street: g'l 'l; 1 Q Fax: 44')F7 - n4-7-QOC 1 City, State Zip:' ) t afpv-_l b.rk F-4 lag State License No.:fEc.(Oo n[,oil D Name: Street: City, St, Zip: Bonding Company: Address: Architect/ Engineer Information Phone: Fax: E- mail: Mortgage Lender: Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYINGTWICEFORIMPROVEMENTSTOYOURPROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction inthisjurisdiction. 1 understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: 5" Edition (2014) Florida Building Code Revised: June 30, 2015 Permit Application r NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may befoundinthepublicrecordsofthiscounty, and there may be additional permits required from other governmental entities such as watermanagementdistricts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713 The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is requiredinordertocalculateaplanreviewchargeandwillbeconsideredtheestimatedconstructionvalueofthejobatthetimeofsubmittal. The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, inaccordancewithlocalordinance. Should calculated charges figured off the executed contract exceed the actual construction value, credit will be applied to your permit fees when the permit is issued. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Signature of Owner/Agent Date Print Owncr/Agent's Name Signature of Notary -State of Florida Date Owner/Agent is Personally Known to Me or Produced ID Type of ID 1aI,gnature of Contractor/Agent Date AP'in C rkactor/Agent's Name fNota StatcofI'londa Date o FAMELASTERNUS y Commission # GG 110ii22 o` Expires August 7, 202.1 FOF Fl; Banded nuu Budget Notary Seri= Contractor/Agent is,>L Personally Known to Me or Produced ID Type of ID BELOW IS FOR OFFICE USE ONLY Permits Required: Building Electrical Mechanical Plumbing[] Gas Roof Construction Type: Total Sq Ft of Bldg: Occupancy Use: Min. Occupancy Load: Flood Zone: of Stories: New Construction: Electric - # of Amps Plumbing - # of Fixtures Fire Sprinkler Permit: Yes No APPROVALS: ZONING: COMMENTS: ENGINEERING: of Heads Fire Alarm Permit: Yes No UTILITIES: FIRE: WASTE WATER: BUILDING: Revised: June 30,2015 Permit Application UNIVERSAL ENGINEERING SCIENCES Consultants In: Geotechnical Engineering • Environmental Sciences Geophysical Services • Construction Materials Testing • Threshold Inspection Building Inspection • Plan Review • Building Code Administration 3532 M9ggie Blvd, Orlando, 32811 • P: 407.423.0504 • F: 407.423.3106 UES Project No: 0110.1700732.0000 Workorder No: 9400462-1 Report Date: 9/28/2018 In -Place Density Test Report Client: Ryan Homes 4307 Vineland Road, Suite H2O Orlando, FL 32811 Project: Kensington Reserve, House Lot Testing UES Technician: Sammie Edwards Date Tested: 09/28/2018 3998 Brisson Avenue, Sanford, Seminole County, FL 32773 Area Tested: 3733 Hanworth Loop (Lot 28) Type of Test: Material: Native Field: ASTM D-2937 Drive Cylinder Method Reference Datum: 0 = Bottom of Footing Laboratory: ASTM D1557 Modified Proctor The tests below meet the minimum 95% relative soil compaction requirement of Laboratory Proctor maximum dry density. Test No. Location of Test Range aximum Density per ptimum Moisture I%t Field Dry Density pcf) Field Moisture Soil Compaction 1%) Native Depth inch) Pass or Fail 1 North Footing 0-1 ft 105.4 12.2 103.4 5.2 98 N/A Pas: 2 South Footing 1-2 ft 105.4 12.2 102.7 3.8 97 N/A Pas: 3 East Footing 1-2 ft 105.4 12.2 100.2 3.0 95 N/A Pas: 4 South East Corner of Pad (TOF) 1-2 ft 105.4 12.2 102.4 11.3 97 N/A Pas: 5 Center of Pad (TOF) 2-3 ft 105.4 12.2 110.6 7.4 105 N/A Pas: Remarks: TOF= Top Of Fill Tn nnlnhl:nl..s m..{. •.sl nn+Mnl:nn M 1 /n:.•mm l n r/:nnln oh- 0..1.1:n n 4 n.....nh• ..II _n #. n.n r..h...:/In•I n•. •.n nr•4nnG: I nn+nn A.• ni n... nl:nn/r nn•4 EESORIPTION AS FURNISHED: Lot 28, KENSINGTON RESERVE, as recorded in Plat Book 81, Pages 86 through 92, Public Records of Seminole County, Florida. BOUNDARY FOR / CERTIFIED TO: Ryan Homes/NVR Inc. LOT 43 LOT 44 LOT 42 S 0019'09" E I 60.00' 0. i i rye. 24.80' 24.80' LOT 28 10.00' 29.0' 0 10.00' w w o000 LOT 29 LOT 27 d' En i' An M 00 FORMBOARD FOUNDATION TOP OF FORMS - 27.48' 0 o e co 5.0' o 0 10.00' 14.0' 21.0' 7 0.00' 26.20' 25.20' 75.20' 10' UTIL. ESMT. 292.86' ry 0 o---_jI--————— - - -- -- S 00019'09" E (B.B.) 60: 00' tib k'1 G HANWOR TH LOOP 50' PRIVATE ROAD PROPOSED = FlNSHEO SPOT GRADE ELEVATIONS BUILDING SETB4CKS: AS FURNISHED FRONT = 25PERDRAINAGEPLANSPLOTPLANAREACALCULATIONSREAR - 20' fir= PROPOSED DRAINAGE FLOW 4 G IMPERVIOUS COVERAGE = 3,0261 SQUARE FEET OR 43.9R SIDE - 5' FOR 40' LOTS LOT GRADING TYPE A LOT CONTAINS 6,9001 SQUARE FEET SIDE - 7.5' FOR 60' LOTSQO PROPOSED FlN15H FLOOR PER PLANS 27.4' UWNG AREA CONTAINS 2,4631 SQUARE FEET SIDE - 10' FOR 75' LOTSQQCONCLANAIPORCHCONTAINS583tSQUAREFEETSIDESTREET = 25' CRUSEINMETYE'R-SCOTT & ASSOC, INC. - LAND SURVEYORS Imo_ LEGDID_ P - PLAY ral. • POW ON LINE 5400 E. COLONIAL DR. ORLANDO, FL. 32807 (407)-277-3232 FAX (407)-658-1436 FIELD TYP. - TYPICALNorm II. . am PPE PAL POINT It REVERSE CURVATURE IF. - CON ROD CL • PODIA or COPm1ND QRVATURE 1. THE UNDERSIGNED DOES HEREBY CERTIFY T!W INS SURVEY UEEP' THE STANDARDS OF PRACTICE SET FORTH BY THE FLORIDA BOARD OF TE SET LA . VILD45% NR Na*-RADIALTRAILPSURVEYORSANDMAPPERSNCHAPTERSJ-17 FLORIDA ADMINISTRATIVE COVE PURSUANT TO SECTION 472.027. FLORIDA STATUES 2. UNLESS EDfBOSSFD WITH SURVEYORS SR:NATVRE AND OPoCOW. RAISED SEAL. INS SURVEY MAP OR COPIES ARE NOT VAUD. RM REcavERED W.P. . WITNESS POINT 3, 1701 SURVEY WAS PREPARED FROM W E DUURAMT10N RMISHED TO THE SURVEYOR. THERE MAY SE OTHER RE57R R;TIONS Pax . POINT OT BEGINNING CALL • CALCULATED OR EASSIENTS TMT AFFECT THIS PROPER'N. P.O.C. . POINT OY CONME1L'EI[NT PAX . PERMANENT REFERD= IOADRNT N - XArLCCNTIIS FF. • FINISHED SETBACK MAD . RAR a DISK K LINE BENCHMOSETIACIELDR 4. NO UHOERCROUND 0/PROVEUENIS HAVE MEN LOCATED UNLESS OTHERWISE SHOWN. I PO SST 6 PREPARED RJR THE SOIE BENEFIT OF 71105E CERTIFIED TO AND SHOULD NOT BE RELIED UPON Or ANY OTHER ENTITY. 3ARN . RIIiR-OT-VAT tIL - BENCHMARK B. L1IAIFNSIO/'IS SHORN FOR THE LOCATION OF WPROVfllEN15 HEREON SHOULD NOT BE USED TO REOONSIRIACT BOUNDARY LINES. ITN EASEMENT B.S. - RASE BEARING DRA DRAINAGE 7. BEARD= ARE BASED ASSUMED OATIDI AND ON THE LINE SHOWN AS SAW BCARDIG (REL) UTIL • UTILITY A ELEVATIONS RN. WSHOWARE ELASED ON 94TXNM CEDOETNC VERTICAL OATUU OF 1929. UNLESS OIHERW6E NOTED. CLEC. - CHAIN LRMa FEE¢ P. CERIFRATE OF AV/IgRRAT10N W 4596 VOEG - V® FENCE C/ R • CONCRETE BLOCK P. C. • POINT I! CU VATIO L SF.V.E 1" 20 — DRAWN BY: ••P P. T. • POINT I3 TANGENCY DCSL - DESCRIPTION GATE COMFTEDBY: R ' RADIUS L ARC LENGTH PLOT PLAN 05-21-18 3163-18 D w FORM80ARD FOUNDATION/ELEVS. 10-01-2018 6626-18 CB. - CHORD BEARING NORTH 5---- THISBUILDMC/PROPERTY DOES NOT UE WITHIN THE ESTABLISHED 100 YEAR FLOOD PLANE AS PER 'FIRM' M CR ISBN R.LS. / 47I4 W. , R.LS / 4ER01 ZONE 7C' MAP 1 12117CO09OF (09-28-07) A CITY OF SANFORD BUILDING & FIRE PREVENTION t *:}• {, PERMIT APPLICATION r Application No: Documented Construction Value: $ Job Address: _1, _5 61 f Historic District: Yes NoK Parcel ID: ResidentiaQ Commercial Type of Work: New Addition Alteration Repair Demo Change of .Use Q Move Description of Work: n . - Plan Review Contact Person: ` ,-_1 I ,l s I- Title:. Phone: Phone: `t-1-j$j 001 Fax:p'1- Email: kyrxke. Can,\ Property Owner Information Name ly N Phone: Street: Q Resident of property? . City, State Zip: Namele- L-4 Street: 53 City, State Zip: Name: Street: City, St, Zip: _ Coritraidtofi Information hono- g 5 - Soo C/ eoarsco Fax: 0 - 3 Q r` State License No.: CACo5 QcILI O Bonding Company: Address: Architect/ Engineer Information Phone: Fax: E- mail: Mortgage Lender: Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST 69 RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Application is hereby made to obtain a permit to do the work and installations as indicated. 1 certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: 51b Edition (2014) Florida Building Code Revised: June 30, 2015 Permit Application a O t 1 10 NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal. The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value, credit will be applied to your permit fees when the permit is issued. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate be done in compliance with all applicable laws regulating. construction and zo g. Signature of Owner/Agent Print Owner/Agent's Name Date Signature.of Notary -State of Florida Date Owner/Agent is Personally Known to Me or Produced ID Type of ID of Contractor/Agent Name at-a4fwork will Signature of No ry-State of Florida Date i%"" CHERYL D AKERS MY COMMISSION # FF998962 dk n EXPIRES June 05, 2020 ao7ja'JaLtS] FloddaPtotaryServke.wn Contractor/Agent is _1,::fPersonall' Known to<Me or Produced ID Type of ID BELOW IS FOR OFFICE USE ONLY Permits Required: Building Electrical Mechanical Plumbing Construction Type: Occupancy Use: Total Sq Ft of Bldg: Min. Occupancy Load: Gas[] Roof Flood Zone: of Stories: New Construction: Electric - # of Amps Plumbing - # of Fixtures Fire Sprinkler Permit: Yes No # of Heads Fire Alarm Permit: Yes No APPROVALS: ZONING: UTILITIES: WASTE WATER: ENGINEERING: FIRE: BUILDING: COMMENTS: Revised: June 30. 2015 Permit Application r) STATEWIDE 1-888-831-2665 D E L-AIR State Cert CAC032448 HEATING • AIR CONDITIONING SAWGRASS OPT POOL BATH SHOWER 3.5 / 2.0 15.0 5 9,373.00 SAWGRASS OPT STUDY 3.5 / 2.0 15.0 4 9,332.00 SEAGATE VERSION III 3.0 15.0 3- 4,977.00 A l I V-R SEAGWI L VERSIbN III OPT BONUS 3.5 ' 0 3 6,530.11(1 SEAGATE VERSION III OPT BONUS BATH 3.5 15.0 4 6,592.00 SEAGATE VERSION III OPT BONUS BDRM 3.5 15.0 4 1$6.702.00 SEASIDE 4.0 15.0 4 5,779.00 SEASIDE OPT OFFICE 4.0 15.0 4 5,926.00 SEASIDE OPT POWDER 4.0 15.0 5 5,901.00 SUMMERLAND 3.5 15.0 4 5,747.00 SUMMERLAND OPT BATH 2 3.5 115.0 5 5,896.00 SUMMERLAND OPT BDRM 5 13.5 115.0 1 5 1$6,019.00 NOTE: PRICING BASED ON NEW CODE. THE DUCT LEAKAGE TEST WAS REQUIRED TO PASS NEW CODE. Pricing valla Tor (b) months JOB NAME: Standard Series - Revised Page 3 of 4 Equipment to be GOODMAN 15 SEER Heat Pump Pricing includes bath duct with standard bath fans, (1) dryer vent box, (1) dryer venting through roof, programmable thermostat (TH6320Ul OOODAG), and a 2nd year warranty. plans with asterisk also have 2-zone damper systems. Add Price for Breakered Heat Strips, Add $35.00 for each unit. Option Price to Add 7" Range Vent, Add $150.00 each. Add Price for Combustion Air for Gas Dryers, Add $90.00 per dryer. For any interior kitchen hood that has a fan greater than 400cfm - Please add $ 475.00 for a Broan MD8TU. For any interior kitchen hood that has a fan greater than 1000cfm - Please add $ 875.00 for a Broan MD8TU and M D6S. For any interior kitchen hood that has a fangreater than 1500cfm - Special provisions must be made. Add $235.00 for increased range vent size if any makeup air is necessary. DEL -AIR must be notified of any interior hood that greater than 400cfm BEFORE rough -in. IN W 31 COnIS('4) %%.%Y s:mr," d. 11. 2771 4117) }1i.(,001 Cust Initials r FIRE INSPECTIONS CITY OF SANFORD 407.562.2786 BUILDING & FIRE PREVENTION BUILDING INSPECTIONS 300 N PARK AVE 855.541.2112 SANFORD FL 32771 DRIVEWAYS -SIDEWALK 407.688.5080 Application Number . . . . . 18-00002854 Date 11/01/18 Application pin number . . . 616308 Property Address . . . . . . 3733 HANWORTH LP Parcel Number . . . . . . . . 17.20.31.SVC-0000-0280 Application type description NEW SINGLE FAMILY HOME - DETACHED Subdivision Name . . . . . . Property Zoning . . . . . . . PUD Application valuation . . . . 275411 Application desc need noc Owner Contractor RYAN HOMES RYAN HOMES 4307 VINELAND RD H20 ORLANDO FL 32811 407) 692-9820 Structure Information 000 000 ---------------------- Construction Type . . . . . VB Occupancy Type . . . . . . RESIDENTIAL USE GROUP Flood Zone . . . . . . . . NONE Other struct info ELEC - # AMPS 200.00 PLUMBING FIXTURES 21.00 NUMBER OF STORIES 1.00 SQUARE FOOTAGE 2581.00 Permit . . . . . . MECHANICAL - NEW RESIDENTIAL Additional desc . . Phone Access Code 1085596 Permit pin number 1085596 Sub Contractor DEL AIR HEATING A/C & REFRIGER Permit Fee . . . . 110.00 Issue Date . . . . 11/01/18 Valuation . . 5139 Expiration Date . . 4/30/19 Qty Unit Charge Per Extension BASE FEE 110.00 Special Notes and Comments All projects within the City shall use WastePro for debris removal. Please contact WastePro at 407.774.0800. Normal hours for inspections are from 7:30 through 4:30 Monday through Thursday. Please be aware you must contact the Building Official to schedule a Friday or after hours inspection. This is required since not every inspector is licensed to do every type inspection. Communication is the key, so please contact the Building Official if you have any questions at 407.688.5058 or at dave.aldrich@sanfordfl.gov Water impact fee $1343.00 Sewer impact fee $3025.00 Other Fees . . . . . . . . . 01-APPLCTN FEE -ELECTRIC 25.00 O1-APPLCTN FEE -BUILDING 25.00 O1-APPLCTN FEE -MECHANIC 25.00 O1-APPLCTN FEE -PLUMBING 25.00 O1-BLDG PLAN REVIEW 1053.00 02-CURB CUT/DRIVE - S/F 40.00 FAILURE TO COMPLY WITH MECHANIC'S LEIN LAW CAN RESULT IN THE PROPERTY OWNER PAYING TWICE FOR BUILDING IMPROVEMENTS. NOTE: ALL FEES MUST BE PAID PRIOR TO C.O. BEING ISSUED. NOTE: PLEASE BE ADVISED ALL PERMITS MUST BE INSPECTED. FIRE INSPECTIONS CITY OF SANFORD 407.562.2786 BUILDING & FIRE PREVENTION BUILDING INSPECTIONS 300 N PARK AVE 855.541.2112 SANFORD FL 32771 DRIVEWAYS -SIDEWALK 407.688.5080 Page 3 Application Number . . . . . 18-00002854 Date 11/01/18 Property Address . . . . . . 3733 HANWORTH LP Parcel Number . . . . . . . . 17.20.31.5VC-0000-0280 Application description . . . NEW SINGLE FAMILY HOME - DETACHED Subdivision Name . . . . . . Property Zoning . . . . . . . PUD Permit . . . . . . MECHANICAL - NEW RESIDENTIAL Additional desc . . Phone Access Code 1085596 Permit pin number 1085596 Required Inspections Phone Insp Seq Insp# Code Description Initials Date 10 409 MHO1 MECHANICAL ROUGH IN 1000 410 MH02 MECHANICAL FINAL / / 15 lightyears, Inc 776 Bennett Drive Longwood, Florida 32750 June 1, 2018 , . To: Local Building Department RE: Blower Door Test & Duct Leakage Test Reports To whom it may concern, 151ightyears This letter is to request that the attached forms be accepted for compliance of the 2017 Florida Building Code statute R402.4.1.2 Envelope leakage testing (Blower Door Testing) and R403.3.3 Duct testing. The attached forms were provided by the Florida Building Commission as the accepted forms to be submitted. These forms are listed on the 2017 Florida Building Code, Energy Conservation Technical Assistance Manual, Document Number: TAM-2017-1.0, released February 02, 2018, pages R-78 through R-80 (page numbers 159-161). Web link provided for quick access to the TAM document https://tinyuri.com/2017FBC-TAM These forms meet all three required Residential Energy Efficiency Compliance Paths listed under R401.2, Prescriptive, Performance, and Energy Rating Index (ERI) paths. We are working with building departments across Florida to standardized the form submittal process and would like your department to allow these forms to meet compliance. If there are any issues with accepting these forms, please reach out to me directly and I will ensure that we submit any specific form that you will require. Tim Smith (407)-951-3236 tsmith@151ightyears.com Respectfully, 2 Timothy fiiith 15 Lightyears, Chief Operations Officer Energy Technical Advisor RESNET Quality Assurance Designee IECC Residential Energy Inspector/ Plans Examiner Member, Building Officials Association of Florida Member and Code Development Committee participating member. Also, representative to the Florida Building Commissions, Energy Technical Advisory Committee for the BOAF- CDC Envelope Leakage Test Report (Blower Door Test) Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Permit #: Job Information Builder: %61ko Community: 1ze r\S'tn +or-\ Lot: Z Address: 3733 k A-, unit: City: State: F( Zip: 32?73 Air Leakage Test Results Passing results must meet either the Performance, Prescriptive, or ERI Method OPRESCRIPTIVE METHOD- The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g. (50 pascals) in Climate Zones 1 and 2. ERFORMANCE or ERI METHOD- The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50) value, as shown on FORM R405-2017 (Performance) or R406-2017 (ERI), section labeled as Infiltration, sub -section ACH50. ACH(50) specified on Form R405-2017-Energy Colc (Performance) or R406-2017 (ERI): = 154? x 60 _ 2o3gZ) = 44 Method for calculating building volume: CFM(50) Building Volume ACH(50) O Retrieved from architectural plans ASS (Mechanical Ventilation is not required) Code software calculated PASS (with Mechanical Ventilation) O Field measured and calculated11FAIL R402.4.1.2 Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure or 0.2 inch w.g. (50 Pascals). Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statues, or individuals licensed as set forth in Section 489.105(3)(f), (g), or (i) or an approved third parry. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or other infiltration control measures. 2.Dampers including exhaust, intake, makeup air, back draft and flue dampers shall be closed, but not sealed beyond intended infiltration control measures. 3.Interior doors, if installed at the time of the test, shall be open. 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5.1-leating and cooling systems, if installed at the time of the test, shall be turned off. 6.Supply and return registers, if installed at the time of the test, shall be fully open. Testing Company Company Name: 15 Lightyears, Inc Phone: (855)438-1515 1 hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requiremen rding to the omp is method selected above. Signature Tester: Date Test: of of Printed Name of Tester: Aaron Overholt License/Certification #: 2DNAB7 Issuing Authority: RESNET Copy of License / Certificate of the tester must be attached) Duct Leakage Test Report Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Permit #: Job Information Builder: RV -A, ^-) Community: ,t 51+-o Lot: 2$ Address: 3 7 33 {-(,a r ua r-k- Unit: City: c5Ar J State: }= ( Zip: 32777 Duct Leakage Test Results System 1 cfm25 System 2 cfm25 System 3 cfm25 Sum of any additional systems cfm25 Total of all systems cfm25 OPrescriptive Method cfm25 (Total) - To qualify as "substantially leak free" Qn Total must be less than or equal to 0.04 if air handler unit is installed. If air handler unit is not installed, Qn Total must be less than or equal to 0.03. This testing method meets the requirements in accordance with Section R403.3.3. Is the air handler unit installed during testing? YES (oa) []NO (s ) 9- Performance / ERI Method cfm25 (out or Total) To qualify using this method, Qn must not be greater than the 3? . 00341 = o •o ( Qn proposed duct leakage Qn specified on Form R405-2017 or R406-2017. Total of all Total Conditioned systems Square Footage Leakage Type selected on Form Qn specified on Form R405-2017 R405- 2017 (Energy Calc) or R406-2017 (Energy Calc) or R406-2017 OASS e r. - % Duct tightness shall be verified by testing in accordance with ANSI/RESNET/ICC380 by either individuals as defined in Section 553. 993(5) or (7), Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(0, (g) or (i), Florida Statutes. Testing Company Company Name: 15 Lightyears, Inc Phone: (855 ) 438-1515 I hereby verify that the above duct leakage testing results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to thence method selected above. Signature of Tester: ( Date of Test: 2- \ t$ Printed Name of Tester: Aaron Overholt License/ Certification #: 2DNAB7 Issuing Authority:: RESNET Copy of License / Certificate of the tester must be attached) LL 1= W z N W Certificate of Achievement THIS ACKNOWLEDGES THAT Aaron Overholt HAS MET THE STANDARD REQUIRED BY RESNET, AS A CERTIFIED RATING FIELD INSPECTOR Certification Date: 08/07/2018 Certification Expires: 08/07/2021 R F I # 2GNAB7 2 ' Tim Smith, RESNET Quality Assurance Designee 15 ears RESNET QA Provider # (1998-199)