Loading...
610, 614, 618, 622, 626, 630 Merry Brook Cir (fr sprnklrs) (a)N Irl N r-1 U N m 0 rn DETAILSPIGOT LOCATION BIRCH UNIT Garage ------------ I\ I I �2 �x\ I ' ` I BR I - ------------------- � a I U I I � I U REDWOOD UNIT SPIGOT LOCATION DETAIL 1/4" = 1`-0" 2' 1' 0 4' 8' I I I SCALE 1/4'= I' Garage ---------------------------------------- 11K ---------------------------------------h i ------------------------------- L_..._.-------- --- -----I �+v�> I U WILLOW UNIT SPIGOT LOCATION DETAIL OUI I L I FIRE SPRINKLER SPIGOT DETAIL SCALE, 1/2' = V Rre **Aclom bm • DESIGN AND INSTALLATION TO BE IN ACCORDANCE WITH 2010 EDITION OF NFPA 13D, LOCAL PLUMBING CODE AND ALL APPLICABLE LOCAL AND STATE CODES. • ALL PLASTIC PIPE 3/4" THROUGH 2Y2" SHALL BE UL LISTED OR FM APPROVED CPVC MANUFACTURED IN ACCORDANCE WITH ASTM F442. • ALL PLASTIC FITTINGS SHALL BE UL LISTED OR FM APPROVED CPVC MANUFACTURED IN ACCORDANCE WITH ASTM F438, ASTM F439 OR ASTM F1970. • ALL CPVC PIPE AND FITTINGS SHALL BE ASSEMBLED USING "ONE STEP" 500 CEMENT. • ALL STEEL PIPE WILL BE SCHEDULE 40 HOT DIPPED GALVANIZED MANUFACTURED IN ACCORDANCE WITH ASTM A795 OR ASTM A-53. • ALL THREADED FITTINGS SHALL BE GALVANIZED MALLEABLE IRON CLASS 150 OR CLASS 300 AND SHALL BE MANUFACTURED IN ACCORDANCE WITH ANSI 1316.3 AND ASTM A 153. • ALL GROOVED FITTINGS SHALL BE UL LISTED OR FM APPROVED AND MANUFACTURED IN ACCORDANCE WITH ASTM A-536 FOR DUCTILE IRON OR ASTM A-47 FOR MALLEABLE IRON. • BRASS PIPE AND FITTINGS WILL BE UTILIZED ONLY AS REQUIRED BY LOCAL WATER PURVEYOR. • WAFS TO PROVIDE CPVC COMPATIBLE AGAVE 14 GAUGE TRACING WIRE ON ALL UNDERGROUND PIPING. • UNDERGROUND MAINS AND LEAD—INS SHALL BE FLUSHED PER FLOW RATES IN NFPA 24 PRIOR TO CONNECTING TO OVERHEAD PIPING. • ALL PIPING SHALL BE BURIED A MINIMUM OF 30 INCHES BELOW GRADE TO THE TOP OF THE PIPE PER WAFS COMPANY STANDARDS. • ALL PIPING UNDER.ROADWAYS SHALL BE BURIED A MINIMUM OF 36 INCHES BELOW GRADE TO THE TOP OF THE PIPE. • ALL PIPING SHALL BE INSPECTED AND APPROVED BY PROPER AUTHORITIES PRIOR TO COVERING, • ALL PIPING SHALL BE TESTED AT 200 PSI FOR 2 HOURS PER WAFS STANDARDS. • VALVES SHALL NOT BE REQUIRED, TO BE MONITORED PER FLORIDA BUILDING CODE 903.4 (1). • ALL PAINTING OF PIPE AS REQUIRED IS BY OTHERS. • WAFS TO PROVIDE ALL NECESSARY SIGNAGE INCLUDING BUT NOT LIMITED TO VALVES, HYDRAULIC PLACARDS, AND INSPECTION TAGS AS REQUIRED BY F5. 633. • SEE CIVIL DRAWINGS FOR DETAILS OF PIPING PRIOR TO WAYNE AUTOMATIC'S POINT OF CONNECTION. • PER FLORIDA STATUTE 633.539, ALL UNDERGROUND FROM THE POINT OF SERVICE TO T-0" AFF SHALL BE INSTALLED BY ONE CLASS I, 11 OR V LICENSED CONTRACTOR. • ALL FERROUS PIPE AND FITTINGS SHALL BE EXTERNALLY WRAPPED AND COATED WITH A BITUMINOUS COATING. • CLEARANCES AROUND FIRE PROTECTION APPLIANCES SHALL BE PROVIDED AS REQUIRED BY LOCAL AUTHORITY. SPRINKLERS SPACING SYMBOL MAXIMUM U MINIMUM lCOMMENTS NFPA 130 2010 E FF. sprWa.rw ka r SPRINKLERS RINKLERS --1 P IST12ND13RD14THI SIN ISIZE1 K FEMd MODEL im 14GA. COPPER LOCATING WIRE (AGAVE WIRE) FINISHED GRADE 71; 1" MAX C-900 FIRE MAIN OR CPVC FIRE MAIN =1" MAX F --LOCATING WIRE F , T— NOTES: i 1. PVC PIPE SHALL REQUIRE INSULATED METALLIC LOCATING WIRE (14 GAUGE COPPER AGAVE WIRE) CAPABLE OF DETECTION BY A CABLE LOCATOR AND SHALL BE BURIED DIRECTLY ABOVE THE CENTERLINE OF THE PIPE. 2. LOCATING WIRE SHALL TERMINATE AT THE TOP OF EACH VALVE BOX AND BE. CAPABLE OF EXTENDING 12" ABOVE TOP OF BOX IN SUCH A MANNER AS TO a NOT INTERFERE WITH VALVE OPERATION. 3. USE FGG/BM COMPATIBLE DUCT TAPE AS NECESSARY TO HOLD WIRE DIRECTLY ON THE TOP OF THE PIPE, TYPICAL LOCATING WIRE DETAIL"VrW'' RYAi SCALE, NO SCALE Automtb Fire SwW&m km 00185N 0 WILKINS MANUFACTURER LIST I3 FPPI NIBCO 4; UNITED BRASS ' T@ SMITH COOPER II TYCO I154 5 PROVALUE NIBCO 14 ARGCO ANVIL SPEARS FPPI 6 SOUTHERN VALVE IMPORT VIKING 8 9 WARD 12 TYCO ASHCROFT ANVIL 10 VICTAULIC (IN ACCORDANCE W/ SHURJOINT ANSI/ASTM A-53) Y4' GALV, THREADED PLUG O 2' DOUBLE DETECTOR CHECK BACKFLOW Y4' BRONZE 3 -WAY PREVENTER W/ BUTTERBALL VALVES, VALVE 13 (SEE MANUF, SPEC SHEET FOR FRICTION 3Y2' WATER LOSS INFORMATION) PRESSURE GAUGE14 1 Y4' X 3' GALV. � 2' GALV, NIPPLE (D + _ 12 GRV, COUPLING �2' X y' GALV, BUSHING O - � 2' GALV, W,A,F,S, TO TIE INTO THE THREADED PLUG OCTAVE METER,I l 2' X3' 2' X 2' X �' O O GALV, NIPPLE GALV, REDUCING TEE 2' GALV, �� 2' X 4' GALV, 10 O TEE C,�� � 1in.,Tll-_,_r1-1 �r , THRD, X GRV, 2' X 3,_8, I-—III—I I —I I 1—III—I i— �. -IT_I=1 �-1TI=il 1=1 I 1=1 t5 GALV, SCH-40-IT_I=11—f—III —II I -III— F -1-r-1 01 IT —1 2' GALV. BFl W,A,F,S, POINT OF O 90° ELL CONNECTION, 2'X3' �2 GALV, NIPPLE TO 2' CPVC 1! , CPVC SYSTEM t1 FEMALE ADAPTER 2' x 1' ' CPVC BUSHING 2" WILKINS 950XLTDABF DOUBLE DETECTOR IAL NOTES CHECK BACKFLOW PREVENTER DETAIL SCALE, NONE ASE SCALE, 1/2" 1' AuWnetb Fin 4rW&m rw. 00675N REV, 2.0 00581L DATE SUBMITPAIS BY IMP0R'PAN1' O WN'�,R INF'QRMAT'IUJV woz'E FIRE SPRINKLER CONSTRUCTION DRAWINGS AND SHOP DRAWINGS MAY INCLUDE WATER SUPPLY INFORMATION DATE- DESIGN CRITERIA Ate' CITY OF SANFORD � CURRENTLY THIS llRAWING IS BASED ON OWNER'S ACCEPTANCE OF THE ,URR NTLY AD PT U E UW E S ADOPTED i r i BACKGR JN➢ DRAWINGS OR GRAPHLS R F M T A IV!_ O AUR OWED RU HE ARCHITECTURAL, G I NO, DATE REVISIONS BY EDITION (EITHER STATE OR LOCAL) OF NFPA 25 AS THEAPPLICABLE STANDARD FUR THE INSPECTION, TESTING AND MAINTENANCE OF WATER BASED FIRE PROTECTION STRUCTURAL, OR MEP DRAWINGS. THESE REFERENCE BACKGROUND ELEMENTS ARE FOR GENERAL INFORMATION OR CONTEXT ONLY AND THE FIRE SPRINKLER ENGINEER DOES DROUGHT OR FIRE PUMP DESIGN SYSTEM /AREA - SYSTEMS. PER SECTION 4.1, THE RESPONSIBILITY FOR PROPERLY MAINTAINING A NOr ACCEPT ANY RESPONSIBILITY FOR THESE ELEMENTS. THE FIRE SPRINKLER ACTUAL EXTRAPOLATED ! WATER BASED FIRE PROTECTION SYSTEM SHALL BE THAT OF THE OWNER,1F THE ENGINEER IS ONLY RESPONSIBLE FOR THOSE PORTIONS OF THE FIRE SPRINKLER (AS REQ D BY AHJ) SIZE, GPM @ PSI BUILDING OWNER HAS NOT RECEIVED COPY OF THIS PAMPHLET AND/OR IS NOT FAMILIAR WITH THE OPERATION AND MAINTENANCE OF THIS SYSTEM, PLEASE CONTACT DRAWINGS DEPICTING FIRESPRINKLER SCOPES OF WORK. REFER TO APPROVED ARCHITECTURAL, STRUCTURAL, MEP OR CIVIL DRAWINGS FOR AUTHORITATIVE EXPRESSIONS OF BACKGROUND INFORMATION THAT MAY BE UTILIZED IN FIRE HAZARD CLASS THE NEAREST OFFICE OF WAYNE AUTOMATIC FIRE SPRINKLERS, INC. SPRINKLER DRAWINGS OR DETAILS STATIC PRESSURE 66 PSI HYDRANT ELEV, 2' # OF SPRINKLERS IN DESIGN AREA RESIDUAL PRESSURE 56 PSI DATE OF TEST 09/06/16 MINIMUM DENSITY CPVC COMPATIBILITY NO'T'ICE CPVC FIRE SPRINKLER PIPING SYSTEMS HAVE BEEN USED SUCCESSFULLY FUR MORE FLOW IN GPM 1010 GPM TIME OF TEST 800 AM THAN 20 YEARS IN NEW CONSTRUCTION, RE -PIPE AND REPAIR. CPVC PRODUCTS ARE IDEALLY SUITED FUR THESE APPLICATIONS DUE TO THEIR OUTSTANDING CORROSION DESIGN AREA S,F, .RESISTANCE. OCCASIONALLY, HOWEVER, .CPVC CAN BE DAMAGED BY CONTACT WITHPITOTREADING 36 PSI NUMBER OF FLOWED 1 _ CHEMICALS FOUND IN SOME CONSTRUCTION MATERIALS (IEI SOME WIRES, FLUX, PETROLEUM BASED PRODUCTS, ETC.) AND ANCILLARY PRODUCTS SUCH AS 'THREAD PSI REWD @ BASR SEALANTS, LEAK DETECTORS, FIRESTOPS, ETC. ANY PRODUCT THAT COMES IN CONTACT WITH CPVC SPRINKLER PIPE MUST BE. EVALUATED 1N ACCORDANCE WITH GPM REQ'D @ BASR THE SYSTEM COMPATIBILITY PROGRAM AS FOUND Ar WWW,SYSTEMCOMPATIBLE.CUM `�. I TEST PROVI➢ED BY WAYNE AUTOMATIC FIRE SPRINKLERS, IMG PSI REQ'D @ TEST _�_�_______ _. -_ __ _ _ __— .., C r7 P YR I Cl =1'I' GPM REQ'D @TEST --^ a ALL DOCUMENTS, INCLUDING ORIGINAL DRAWINGS, SPECIFICATIONS, FIELD NOTES, ESTIMATES AND BATA, INCLUDING COMPUTER PROGRAMS PURSUANT TO THIS PROJECT ELEVATION @ HIGHEST CY) r! ARE AND WILL REMAIN THE PROPERTYOF WAYNE AUTOMATIC FIRE SPRINKLERS, INC. (WAFS) AS 1NSrRUMENTS OF SERVICE,THEY ARE NOT INTENDED, NOR REPRESENTED � SPRINKLER N TO BE SUITABLE FOR RE -USE BY THE CLIENT, OR OTHERS, ON EXTENSION OF THIS )OSE PROJECT, OR FOR ANY UrHER PROJECT, ANY REUSE, OR ADAPTATION OF THE HYDRANT NFORMATION CONTAINED HEREIN, WITHOUT SPECIFIC WRITTEN PERMISSION FROM WAFS WILL BE AT THE ILIENI'S SOLE RISK, WITHOUT LIABILITY, OR LEGAL EXPOSURE TO LOCATION OR TEST HYDRANT LOCATED ON WHITE CEDAR ROAD INSIDE/OUTSIDE Q0 WAFS, AND WILL ENTITLE WAFS TO FURTHER COMPENSATION AT RATES TO BE - NUMBER DOMESTIC DEMAND c-! CD AGREED ON BETWEEN WAFS AND THE CLIENT, THE CLIENT SHALL ALSO INDEMNIFY AND HOLD WAFS HARMLESS FROM ANY AND ALL CLAIMS DAMAGES, LOSSES ArID N EXPENSES, INCLUDING ATTORNEYS FEES RESULTING FROM ANY SUCH PERMISSIONS. t. r -I - rn • DESIGN AND INSTALLATION TO BE IN ACCORDANCE WITH 2010 EDITION OF NFPA 13D, LOCAL PLUMBING CODE AND ALL APPLICABLE LOCAL AND STATE CODES. • ALL PLASTIC PIPE 3/4" THROUGH 2Y2" SHALL BE UL LISTED OR FM APPROVED CPVC MANUFACTURED IN ACCORDANCE WITH ASTM F442. • ALL PLASTIC FITTINGS SHALL BE UL LISTED OR FM APPROVED CPVC MANUFACTURED IN ACCORDANCE WITH ASTM F438, ASTM F439 OR ASTM F1970. • ALL CPVC PIPE AND FITTINGS SHALL BE ASSEMBLED USING "ONE STEP" 500 CEMENT. • ALL STEEL PIPE WILL BE SCHEDULE 40 HOT DIPPED GALVANIZED MANUFACTURED IN ACCORDANCE WITH ASTM A795 OR ASTM A-53. • ALL THREADED FITTINGS SHALL BE GALVANIZED MALLEABLE IRON CLASS 150 OR CLASS 300 AND SHALL BE MANUFACTURED IN ACCORDANCE WITH ANSI 1316.3 AND ASTM A 153. • ALL GROOVED FITTINGS SHALL BE UL LISTED OR FM APPROVED AND MANUFACTURED IN ACCORDANCE WITH ASTM A-536 FOR DUCTILE IRON OR ASTM A-47 FOR MALLEABLE IRON. • BRASS PIPE AND FITTINGS WILL BE UTILIZED ONLY AS REQUIRED BY LOCAL WATER PURVEYOR. • WAFS TO PROVIDE CPVC COMPATIBLE AGAVE 14 GAUGE TRACING WIRE ON ALL UNDERGROUND PIPING. • UNDERGROUND MAINS AND LEAD—INS SHALL BE FLUSHED PER FLOW RATES IN NFPA 24 PRIOR TO CONNECTING TO OVERHEAD PIPING. • ALL PIPING SHALL BE BURIED A MINIMUM OF 30 INCHES BELOW GRADE TO THE TOP OF THE PIPE PER WAFS COMPANY STANDARDS. • ALL PIPING UNDER.ROADWAYS SHALL BE BURIED A MINIMUM OF 36 INCHES BELOW GRADE TO THE TOP OF THE PIPE. • ALL PIPING SHALL BE INSPECTED AND APPROVED BY PROPER AUTHORITIES PRIOR TO COVERING, • ALL PIPING SHALL BE TESTED AT 200 PSI FOR 2 HOURS PER WAFS STANDARDS. • VALVES SHALL NOT BE REQUIRED, TO BE MONITORED PER FLORIDA BUILDING CODE 903.4 (1). • ALL PAINTING OF PIPE AS REQUIRED IS BY OTHERS. • WAFS TO PROVIDE ALL NECESSARY SIGNAGE INCLUDING BUT NOT LIMITED TO VALVES, HYDRAULIC PLACARDS, AND INSPECTION TAGS AS REQUIRED BY F5. 633. • SEE CIVIL DRAWINGS FOR DETAILS OF PIPING PRIOR TO WAYNE AUTOMATIC'S POINT OF CONNECTION. • PER FLORIDA STATUTE 633.539, ALL UNDERGROUND FROM THE POINT OF SERVICE TO T-0" AFF SHALL BE INSTALLED BY ONE CLASS I, 11 OR V LICENSED CONTRACTOR. • ALL FERROUS PIPE AND FITTINGS SHALL BE EXTERNALLY WRAPPED AND COATED WITH A BITUMINOUS COATING. • CLEARANCES AROUND FIRE PROTECTION APPLIANCES SHALL BE PROVIDED AS REQUIRED BY LOCAL AUTHORITY. SPRINKLERS SPACING SYMBOL MAXIMUM U MINIMUM lCOMMENTS NFPA 130 2010 E FF. sprWa.rw ka r SPRINKLERS RINKLERS --1 P IST12ND13RD14THI SIN ISIZE1 K FEMd MODEL im 14GA. COPPER LOCATING WIRE (AGAVE WIRE) FINISHED GRADE 71; 1" MAX C-900 FIRE MAIN OR CPVC FIRE MAIN =1" MAX F --LOCATING WIRE F , T— NOTES: i 1. PVC PIPE SHALL REQUIRE INSULATED METALLIC LOCATING WIRE (14 GAUGE COPPER AGAVE WIRE) CAPABLE OF DETECTION BY A CABLE LOCATOR AND SHALL BE BURIED DIRECTLY ABOVE THE CENTERLINE OF THE PIPE. 2. LOCATING WIRE SHALL TERMINATE AT THE TOP OF EACH VALVE BOX AND BE. CAPABLE OF EXTENDING 12" ABOVE TOP OF BOX IN SUCH A MANNER AS TO a NOT INTERFERE WITH VALVE OPERATION. 3. USE FGG/BM COMPATIBLE DUCT TAPE AS NECESSARY TO HOLD WIRE DIRECTLY ON THE TOP OF THE PIPE, TYPICAL LOCATING WIRE DETAIL"VrW'' RYAi SCALE, NO SCALE Automtb Fire SwW&m km 00185N 0 WILKINS MANUFACTURER LIST I3 FPPI NIBCO 4; UNITED BRASS ' T@ SMITH COOPER II TYCO I154 5 PROVALUE NIBCO 14 ARGCO ANVIL SPEARS FPPI 6 SOUTHERN VALVE IMPORT VIKING 8 9 WARD 12 TYCO ASHCROFT ANVIL 10 VICTAULIC (IN ACCORDANCE W/ SHURJOINT ANSI/ASTM A-53) Y4' GALV, THREADED PLUG O 2' DOUBLE DETECTOR CHECK BACKFLOW Y4' BRONZE 3 -WAY PREVENTER W/ BUTTERBALL VALVES, VALVE 13 (SEE MANUF, SPEC SHEET FOR FRICTION 3Y2' WATER LOSS INFORMATION) PRESSURE GAUGE14 1 Y4' X 3' GALV. � 2' GALV, NIPPLE (D + _ 12 GRV, COUPLING �2' X y' GALV, BUSHING O - � 2' GALV, W,A,F,S, TO TIE INTO THE THREADED PLUG OCTAVE METER,I l 2' X3' 2' X 2' X �' O O GALV, NIPPLE GALV, REDUCING TEE 2' GALV, �� 2' X 4' GALV, 10 O TEE C,�� � 1in.,Tll-_,_r1-1 �r , THRD, X GRV, 2' X 3,_8, I-—III—I I —I I 1—III—I i— �. -IT_I=1 �-1TI=il 1=1 I 1=1 t5 GALV, SCH-40-IT_I=11—f—III —II I -III— F -1-r-1 01 IT —1 2' GALV. BFl W,A,F,S, POINT OF O 90° ELL CONNECTION, 2'X3' �2 GALV, NIPPLE TO 2' CPVC 1! , CPVC SYSTEM t1 FEMALE ADAPTER 2' x 1' ' CPVC BUSHING 2" WILKINS 950XLTDABF DOUBLE DETECTOR IAL NOTES CHECK BACKFLOW PREVENTER DETAIL SCALE, NONE ASE SCALE, 1/2" 1' AuWnetb Fin 4rW&m rw. 00675N REV, 2.0 00581L DATE SUBMITPAIS BY 09/13/16 QA REVIEW MPF TOTAL A/S, 110 DATE- SEPTEMBER 12, 2016 Ate' CITY OF SANFORD CONTRACT # 84196 oh CENTER OF TILE JOB? [] YES NO CENTER ON FIXTURES JOB? Q YES NO SHEET # CONSTRUCTION TYPE, V -B OCCUPANCY PS,2 R-3 NO, DATE REVISIONS BY WAI"W IE AUtumatic Fire Sprinklers, Inc. MAIN OFFICE — ORLANDO, FLORIDA 222 CAPITOL COURT OCOEE, FLORIDA 34761 PHONE: (407) 65B-3030 FAX: (407) 856-8026 JACKSONVILLE. FL TAMPA, FL POMPANO BEACH. FL 11326 DISTRIBUTION AVE WEST 3226 CHERRY PALM OWVE 13121 NW 16TH TERRACE JACKSONVLLE, FL 32256-2745 TAMPA, FL 33619-8337 POMPANO BEACH, FL 33064-140E PHONE: (904) 268-3030 PHONE: (813) 830-0303 PHONE: (954) 917-3030 FAX (904) 268-0724 FAX: (813) 630-0312 FAX: (954) 917-9424 FT. MYEFIS, FL CONCORD. NC STATE LICENSES: 4683 LAREDO AVE 4370 MOTORSPORT DRIVE NC SPRINKLER: 29745 CONCORD NC 2827 -BFT. FT. MYEAS FL 33905 02 977 4924 NC ALARM; 29222 SP LV PHONE (239) 433-3030 PHONE: (704) 782-3032 SC SPRINKLER: 1118 FAX. (239) 433-3283 FAX: (704) 795-6838 SC ALARM: 3385, . 0 LOTS 64-69 THO RN B E R00 KE TOW NHO MES WHITE CEDAR ROAD SANFORD FL 32771 TAYLOR MORRISON HOMES 151 SOUTHHALL LANE, SUITE 200 MAITLAND, FL 32751 SHEET TITLE, FIRE PROTECTION SITE NOTES & DETAILS PLAN DRAVN BY, MICKEY FERGUSON TOTAL A/S, 110 DATE- SEPTEMBER 12, 2016 Ate' CITY OF SANFORD CONTRACT # 84196 oh CENTER OF TILE JOB? [] YES NO CENTER ON FIXTURES JOB? Q YES NO SHEET # CONSTRUCTION TYPE, V -B OCCUPANCY PS,2 R-3 is ■ PIPE SIZE INCHES %' CURE 200 PSI TIMES WITH (MAXIMUM) ONE STEP SOLVENT CEMENT TEST PRESSURE (SEE NOTE 1) HR, PIPE SIZE INCHES AMBIENT TEMPERATURE DURING CURE 60°F TO 120°F 40°F TO 59°F PERIOD 0°F TO 39°F %' 45 MIN, 1,5 HR, 24 HR, 1' 45 MIN, 1,5 HR. 24 HR. 1Y4" 1.5 HR, 16 HR, 120 HR, lY2' 1.5 HR, 16 HR,. 120 HR, 2' 6 HR. 36 HR, SEE NOTE 2 22 8 HR, 72 HR, SEE NOTE 2 LL3' 8 HR, 72 HR. SEE NOTE 2 PIPE SIZE INCHES %' CURE TIMES WITH ONE STEP SOLVENT CEMENT 225 PSI (MAXIMUM) TEST PRESSURE (SEE NOTE U AMBIENT TEMPERATURE DURING CURE PERIOD 60°F TO 120°F 40°F TO 59°F 0°F TO 39°F 1 HR. 4 HR, 48 HR, 1' 1.5 HR, 4 HR, 48 HR, lY4' 3 HR. 32 HR, 10 DAYS ly' 3 HR, 32 HR. 10 DAYS 2" 8 HR. 48 HR, SEE NOTE 2 2Y2' 24 HR, 96 HR, SEE NOTE 2 3' 24 HR. 96 HR, SEE NOTE 2 NOTE 1: THESE CURE TIMES ARE FOR NEW CONSTRUCTION. IF GLUING INTO EXISTING PIPINA CU Irk AS IN TME CASE OF ['lP -&n C_I IRP TIMP m4ni it n RP A MINIMI IAA ALL MATERIAL APPLICABLE TO THIS PROJECT WILL R MAX ANY DISTANCE S AX HANGER DE INDICATED WITH A (V) (1/2 'S' MAX) OR CLAMP (TYP,) ALL PLASTIC PIPE 3/4" THROUGH 2)'2" SHALL BE UL LISTED OR FM APPROVED CPVC MANUFACTURED IN ACCORDANCE WITH ASTM F-442. ALL PLASTIC FITTINGS SHALL BE UL LISTED OR FM APPROVED CPVC MANUFACTURED IN ACCORDANCE WITH ASTM F43B, ASTM F439 OR ASTM F1970. V ALL CPVC PIPE AND FITTINGS SHALL BE ASSEMBLED USING 'ONE STEP' 500 CEMENT. �R UNHEATED CPVC PIPE SHALL BE ALLOWED TO BE USED IN ORDINARY HAZARD ROOMS OF 400 SQUARE FEET OR INSULATION ATTIC LESS OF OTHERWISE LIGHT HAZARD OCCUPANCIES (NFPA 13 SECTION 6.3.6.2 OR NFPA 13R SECTION (BY OTHERS) SPRINKLER TEE DROP SUPPORT SPACING WITH SPRINKLER DROP SUPPORT SPACING 5.2.2.3). ONE RESTRAINT POINT - SEE TABLE 1 BELOW WITH TWO RESTRAINT POINTSALL - ts6SS��Rsa coy SEE TABLE 2 BELOW ❑ 1" TO THREADED BLACK STEEL PIPE SHALL BE UL LISTED/FM APPROVED AND MANUFACTURED IN ACCORDANCE WITH ASTM A-135 OR A-795. ACCEPTABLE PIPE BRANDS ARE WHEATLAND CEILING R MAX 'MEGATHREAD', ALLIED 'OYNATHREAD', BULL MOOSE TUBE 'EODYTHREAD' AND WELDED TUBE -BERKELEY 19'-8" L FEET L MAX I 'STEADY -THREAD'. ALL PIPE SHALL BE CPVC COMPATIBLE. HEATED HEATED " ❑ ALL 1" T0.2" THREADED GALVANIZED PIPE WILL BE SCHEDULE 40 HOT DIPPED GALVANIZED UNIT UNIT MANUFACTURED IN ACCORDANCE WITH ASTM A-795 OR ASTM A-53. 2 ~ ` D ❑ ALL 1" TO 2" THREADED BLACK STEEL PIPE SHALL BE SCHEDULE 40 UL LISTED/FM APPROVED AND A - 0 329 d INCHES - MANUFACTURED IN ACCORDANCE WITH ASTM A-795. ACCEPTABLE PIPE MANUFACTURERS ARE D WHEATLAND, ALLIED, BULL MOOSE TUBE AND WELDED TUBE -BERKELEY. ALL PIPE SHALL BE CPVC = _ COMPATIBLE. SPRINKLER 90° ELL DROP SUPPORT SPACING WITH❑ ALL W4 TO 4" GROOVED BLACK STEEL PIPE SHALL BE UL LISTED/FM APPROVED AND MANUFACTURED MAXIMUM SUPPORT SPACING IN ACCORDANCE WITH ASTM A795. ACCEPTABLE BRANDS ARE BULL MOOSE 'EDDYFLOW', WHEATLAND ONE RESTRAINT POINT - SEE TABLE 1 BELOW SEE TABLE 3 BELOW 'MEGA -FLOW' ALLIED 'DYNA-FLOW' AND WELDED TUB CPVC COMPATIBLE. PERMISSIBLE BENDING DEFLECTIONS SDR 13,5 (ONE END RESTRAINED) (73°F) 3/ INCH 0'-9' PIPE SIZE INCHES 1 INCH F-0" LENGTH OF RUN (L) IN FEET 2' 5' 7' 10' 12' 2' 5' 7' 10' 12' 15' 17' 20' Y4' 113" 7,8' 15,4' 31,3' 45,1' 70,5' 90.6' 125.4' 1' 1,0' 6,3' 123' 25.0' 36,0' 563' 723' 100,1' 3, 0,8' 5.0' 9,7" 19,8" 28.5' 44,6' 57.3' 79.3' IV 0,7' 4,3' 8,5" 17,3" 243' 39,0' 50.1' 693' 2' 0,6' 3,5' 6,8' 13.9' 20,0' 31,2" 40,0" 55,4' 2V 0,5' 2,9' 5.6' 11,4' 16,5' 25,8 33.1' 45,8' 3" 0.4' 2,4' 4.6' 1 9,4" 1 13S' 21.2" 27,2' 37,6' ALL MATERIAL APPLICABLE TO THIS PROJECT WILL R MAX ANY DISTANCE S AX HANGER DE INDICATED WITH A (V) (1/2 'S' MAX) OR CLAMP (TYP,) ALL PLASTIC PIPE 3/4" THROUGH 2)'2" SHALL BE UL LISTED OR FM APPROVED CPVC MANUFACTURED IN ACCORDANCE WITH ASTM F-442. ALL PLASTIC FITTINGS SHALL BE UL LISTED OR FM APPROVED CPVC MANUFACTURED IN ACCORDANCE WITH ASTM F43B, ASTM F439 OR ASTM F1970. V ALL CPVC PIPE AND FITTINGS SHALL BE ASSEMBLED USING 'ONE STEP' 500 CEMENT. �R UNHEATED CPVC PIPE SHALL BE ALLOWED TO BE USED IN ORDINARY HAZARD ROOMS OF 400 SQUARE FEET OR INSULATION ATTIC LESS OF OTHERWISE LIGHT HAZARD OCCUPANCIES (NFPA 13 SECTION 6.3.6.2 OR NFPA 13R SECTION (BY OTHERS) SPRINKLER TEE DROP SUPPORT SPACING WITH SPRINKLER DROP SUPPORT SPACING 5.2.2.3). ONE RESTRAINT POINT - SEE TABLE 1 BELOW WITH TWO RESTRAINT POINTSALL - ts6SS��Rsa coy SEE TABLE 2 BELOW ❑ 1" TO THREADED BLACK STEEL PIPE SHALL BE UL LISTED/FM APPROVED AND MANUFACTURED IN ACCORDANCE WITH ASTM A-135 OR A-795. ACCEPTABLE PIPE BRANDS ARE WHEATLAND CEILING R MAX 'MEGATHREAD', ALLIED 'OYNATHREAD', BULL MOOSE TUBE 'EODYTHREAD' AND WELDED TUBE -BERKELEY 19'-8" L FEET L MAX I 'STEADY -THREAD'. ALL PIPE SHALL BE CPVC COMPATIBLE. HEATED HEATED " ❑ ALL 1" T0.2" THREADED GALVANIZED PIPE WILL BE SCHEDULE 40 HOT DIPPED GALVANIZED UNIT UNIT MANUFACTURED IN ACCORDANCE WITH ASTM A-795 OR ASTM A-53. 2 ~ ` D ❑ ALL 1" TO 2" THREADED BLACK STEEL PIPE SHALL BE SCHEDULE 40 UL LISTED/FM APPROVED AND A - 0 329 d INCHES - MANUFACTURED IN ACCORDANCE WITH ASTM A-795. ACCEPTABLE PIPE MANUFACTURERS ARE D WHEATLAND, ALLIED, BULL MOOSE TUBE AND WELDED TUBE -BERKELEY. ALL PIPE SHALL BE CPVC = _ COMPATIBLE. SPRINKLER 90° ELL DROP SUPPORT SPACING WITH❑ ALL W4 TO 4" GROOVED BLACK STEEL PIPE SHALL BE UL LISTED/FM APPROVED AND MANUFACTURED MAXIMUM SUPPORT SPACING IN ACCORDANCE WITH ASTM A795. ACCEPTABLE BRANDS ARE BULL MOOSE 'EDDYFLOW', WHEATLAND ONE RESTRAINT POINT - SEE TABLE 1 BELOW SEE TABLE 3 BELOW 'MEGA -FLOW' ALLIED 'DYNA-FLOW' AND WELDED TUB CPVC COMPATIBLE. PERMISSIBLE BENDING DEFLECTIONS SDR 13.5 (BOTH ENDS RESTRAINED) (73°F) 3/ INCH 0'-9' PIPE SIZE INCHES 1 INCH F-0" LENGTH OF RUN (L) IN FEET IY INCH 1'-4' 2' 5' 7' 10' 12' 15' 17' 20' Y4" 0,3' 2,0" 3.8' 7,8" 11,3' 17,6" 22,6' 31.3' 1' 0,3' 1,6' 3,1' 6.3' 9,0" 14,1' 1811' 25.0' 1' # 0,2' 1,2' 2,4' 5,0' TV 1112' 14.3' 19,8" 1ST" 0,2' 1,1' 2.1' 4,3" 6,2' 9,7' 12.5' 17,3' 2' 0.1' 0,9' 1,7' 3,5' 5,0' 7,$' 10,0' 13.9" 2V 0.1' 0,7" 1,4' 2,9' 4,1' 6,4" 8,3' 11,4' 3' 0.1" 0,6" 1.2' 2,4" 3,4" 5,3' 11 TABLE 1 - SPRINKLER SUPPORT SPACING DISTANCE WITH ONE RESTRAINT POINT NOM, PIPE SIZE 'R' @ LESS THAN 100 PSI 'R' @ GREATER THAN 100 PSI 3/ INCH 0'-9' 0'-6' 1 INCH F-0" 0'-9' IY INCH 1'-4' 1'-0' ly INCH 2'-0' 1'-0' AY INCH 2'-0' V-0' TABLE 2 - SPRINKLER SUPPORT SPACING DISTANCE WITH TWO RESTRAINT POINTS NOM, PIPE SIZE 3/4 INCH 'S' @ LESS THAN 100 PSI 4'-0' 'S' @ GREATER THAN 100 PSI 3'-0' 1 INCH 5'-0' 4'-0' 1Y INCH 6'-0' 5'-0' 1Y2 INCH 7'70' 7'-0' MY INCH 7'-0' 7'-0' E -BERKELEY STEADY -FLOW. ALL PIPE SHALL BE ❑ ALL W4" TO 4" GROOVED BLACK STEEL PIPE SHALL BE SCHEDULE 10, UL LISTED/FM APPROVED AND _ {�I} 2ND FLOOR MANUFACTURED IN ACCORDANCE WITH ASTM A-795. ACCEPTABLE MANUFACTURERS ARE BULL tr MOOSE, WHEATLAND, ALLIED AND WELDED TUBE -BERKELEY. ALL PIPE SHALL BE CPVC COMPATIBLE. CEILIN❑ 9'-4"G ALL GROOVED STEEL PIPE 6' AND LARGER SHALL BE UL LISTED/FM APPROVED SCHEDULE 10 AND MANUFACTURED IN ACCORDANCE WITH ASTM A-135. r ❑ ALL GROOVED STEEL PIPE IY4' AND LARGER SHALL BE SCHEDULE 10 HOT DIPPED GALVANIZED AND HEATED HEATED MANUFACTURED IN ACCORDANCE WITH ASTM A-795. UNIT UNIT ❑ ALL STEEL PIPE SHALL HAVE A CORROSION RESISTANCE RATIO (CRR) OF NOT LESS THAN 1.0 PER WAFS STANDARDS. [_] ALL BLACK THREADED FITTINGS SHALL BE DUCTILE IRON CLASS 150 OR CLASS 300 ANSI 816.3, CAST IRON CLASS 125 OR CLASS 250 ANSI BIBA OR MALLEABLE IRON CLASS 150 OR CLASS 300 ANSI B16.3. yr c'* rwvna, U ALL GALVANIZED THREADED FITTINGS SHALL BE MALLEABLE IRON CLASS 150 OR CLASS 300 ANSI L FEET �--�--- B16.3 WITH GALVANIZED COATING IN ACCORDANCE WITH ASTM A-153. NOTE 21 FOR THESE SIZES, THE SOLVENT CEMENT CAN BE APPLIED A7 TEMPERATURESi II [:] TABLE 3 -MAXIMUM SUPPORT SPACING .1ST FLOOR ALL WELDED OUTLETS SHALL BE UL LISTED OR FM APPROVED AND MANUFACTURED IN ACCORDANCE BELOW 32°F, HOWEVER, THE SPRINKLER SYSTEM TEMPERATURE MUST BE RAISED TO A WITH ANSI B16.11. TEMPERATURE OF 32°F OR ABOVE AND ALLOWED TO CURE PER THE ABOVE NOM, PIPE INCH 1 INCH 1� INCH l� INCH 2 INCH 2 INCH 3 INCH RECOMMENDATIONS PRIOR TO PRESSURE TESTING, \ D / SIZE ❑ GROOVED FITTINGS SHALL BE UL LISTED OR FM APPROVED AND MANUFACTURED IN ACCORDANCE WITH L2 \ \\ d INCHES /� / SUPPORT 6'-O' ASTM A-536 FOR DUCTILE IRON OR ASTM A-47 FOR MALLEABLE IRON. d = 0'0823 - 5'-6" 6'-6' 7'-O' 8'-O" 9'-O' 10'-O' D SPACING 'L' ❑ ALL GALVANIZED GROOVED FITTINGS SHALL BE UL LISTED OR FM APPROVED AND MANUFACTURED IN � � � � � � / \ ` / ACCORDANCE WITH ASTM A-536 FOR DUCTILE IRON OR ASTM A-47 FOR MALLEABLE IRON. f GALVANIZED COATING SHALL BE IN ACCORDANCE WITH ASTM A-153. ❑ ALL GROOVED STEEL PIPE SHALL B5 ROLL GROOVED PER PIPE MANUFACTURER REQUIREMENTS, TYPICAL CPVC CURE TIMES CPVC BENDING DEFLECTIONS TYPICAL CPVC HANGER/BRACE SPACING PIPE AND FITTINGS GENERAL NOTES TYPICAL RESIDENTIAL CROS � SCALE: NONE SCALE: NONE C�l SCALE= NONES SECTION - � F AYN� ��YRE\"V*WLYwNwiE TYPICAL NONE FLOOR mommenumomm Automatic Fire Sprinklore, Inc. Automatic Fire Sprinklers, Inc. Automatic Fire 5prinklere, Inc. AubwAtlo Fire Sprk4dam hw Y�E SCALEI NONE Automatic Fire Sprinklore, Inc. 00415N 00416N 00356N 00859N 00683N CEILING #12 X ly' HARDENED CPVC SPRINKLER CEILING STRAP MAY BE USED HEX HEAD >1 ALTERNATE USAGE OF TYPICAL CEILING IN THIS POSITION AS SELF -THREADING LINE (%' TO 2') A FIG. 24 PIPE HANGER DIFFUSER A RESTRAINER ONLY SCREW 1'-0' TOLCO FIG, #22C VIEW 'A' SOFFIT (CONSISTING OF (2} TYP TYP. _ TYP, (OBSTRUCTION) B TYPICAL PENDENT = TOLCO FIG, 22 PIPE SPRINKLER CPVC SPRINKLER STRAPS) 1'-0' 3 + WOOD FRAMING TYPICAL B TYP 'INTO MIEDIATV LINE (/4 TO 2) ® MEMBERPENENT SPRINKLER A TYPICAL TEMPER OBSTRUCTION < �� CLASSIFICATO VIEW A ALTERNATE USAGE OF FIG. 24 PIPE HANGER D------�-- A SEE DETAIL VIEW - DETAILVIEW WALL � F IH F) A A Z (D - 8 IN.)+ B (A > (D - 0,2M) + B} 0 0 d TOLCO FIG, 22 I °' ®� d PIPE STRAP WOOD FRAMING 0 X , E D S 30 IN, (0.8M) ®� `� (SIZED TO PIPE) MEMBER #12 X 1Y #1HARDENED PIPE TOLCO HANGER 4 CPVC SPRINKLER HEX HEAD LINE (%' TO 2') WOOD FRAMING SELF -THREADING SCREW HEAD SELF ARENED ING EX (X2) SCREW (X2) MEMBER DISTANCE FROM SPRINKLER TO SIDE OF OBSTRUCTION (A) MAXIMUM ALLOWABLE DISTANCE OF DEFLECTOR ABOVE BOTTOM OF OBSTRUCTION (INJ (B) LESS THAN 1 FT, 6 IN. 0 1 FT, 6 IN TO LESS THAN 3 FT, 1 3 FT. TO LESS THAN 4 FT, 3 4 FT, TO LESS THAN 4 FT. 6 IN, 5 4 FT, 6 IN, TO LESS THAN 6 FT, 7 6 FT, TO LESS THAN 6 FT, 6 IN, 9 6 FT, 6 1N, TO LESS THAN 7 FT, 11 7 FT, AND GREATER 14 NFPA 13R G 13D RESIDENTIAL PENDENT HANGER #04F HANGER #04J NFPA 13R 8 130 RESIDENTIAL PENDENT TYPICAL RESIDENTIAL CEILING MOUNTED HOT AIR SPRINKLER CLEARANCE W/ SOFFIT FOR 3/4" TO 2" CPVC PIPE HANGER #046 FOR 3/4" TO 2" CPVC PIPE FIG. 24 HANGER FOR 3/4" TO 2" CPVC PIPE SPRINKLER CLEARANCE W/ OBSTRUCTION DIFFUSER SPRINKLER MINIMUM CLEARANCES SCALE: NONE � SCALE: NONE � SCALE: NONE � I SCALE NONE A�� AYNE AYNE YNE SCALE: NONE ��� SCALE: NONE Automatic Fire Sprinklara, Ins. 00531N Autowitic Rn Irm 00251N Autuawtia �'" ��•• Iran 00250N Aubm" � mss. iw. 00282N Automatic Fire Sprinklera, Inc. 00527N Automatic Fire Sprinklura, Inc. 00702N IIvL1--1OR'I'ANT OWNER 1NF'ORNIAPI0N CRAPHICS ELEN1ENr'S NU PE 'WDINAR1f' FIRE SPRINKLER CONSTRUCTION DRAWINGS AND SHOP DRAWINGS MAY NCLJDF Y ] ED1l TON (EITHER BA K RUUND DRAWINGS OR GRAPHICS BORROWED FROM THE ARCHITECTURAL, CIVIL STRUCTURAL, OR MEP DRAWINGS. THESE REFERENCE BACKGROUND ELEMENTS AREFOR TEMPERATURE ' 111MIFICATIIN 2'-0' WATER BASED FIRE PROTECTION SYSTEM SHALL BE THAT OF THE OWNER, IF THE TYP, BUILDING OWNER HAS NOT RECEIVED A COPY OF THIS PAMPHLET AND/OR IS NOT I R2'-0' TYP, EXPRESSIONS OF BACKGROUND INFORMATION THAT MAY BE UTILIZED IN FIRE HAZARD CLASS TYP, NOTE: SPRINKLERS MUST BE LOCATED OUTSIDE OF SHADED AREA NFPA 13R G 13D RESIDENTIAL PENDENT HANGER #04F HANGER #04J NFPA 13R 8 130 RESIDENTIAL PENDENT TYPICAL RESIDENTIAL CEILING MOUNTED HOT AIR SPRINKLER CLEARANCE W/ SOFFIT FOR 3/4" TO 2" CPVC PIPE HANGER #046 FOR 3/4" TO 2" CPVC PIPE FIG. 24 HANGER FOR 3/4" TO 2" CPVC PIPE SPRINKLER CLEARANCE W/ OBSTRUCTION DIFFUSER SPRINKLER MINIMUM CLEARANCES SCALE: NONE � SCALE: NONE � SCALE: NONE � I SCALE NONE A�� AYNE AYNE YNE SCALE: NONE ��� SCALE: NONE Automatic Fire Sprinklara, Ins. 00531N Autowitic Rn Irm 00251N Autuawtia �'" ��•• Iran 00250N Aubm" � mss. iw. 00282N Automatic Fire Sprinklera, Inc. 00527N Automatic Fire Sprinklura, Inc. 00702N IIvL1--1OR'I'ANT OWNER 1NF'ORNIAPI0N CRAPHICS ELEN1ENr'S NU PE THIS DRAW BASED ON THE OWNERS ACCEPTANCE OF THE CURRENTLY ADOPTED INGLS FIRE SPRINKLER CONSTRUCTION DRAWINGS AND SHOP DRAWINGS MAY NCLJDF Y ] ED1l TON (EITHER BA K RUUND DRAWINGS OR GRAPHICS BORROWED FROM THE ARCHITECTURAL, CIVIL STRUCTURAL, OR MEP DRAWINGS. THESE REFERENCE BACKGROUND ELEMENTS AREFOR THE INSPECTION, TESTING AND MAINTENANCE OF WATER BASED FIRE PROTECTION GENERAL 1NFORMA'NON OR CONTEXT ONLY AND THE FIRE SPRINKLER ENGINEER DOES SYSTEMS. PER SECTION 4.1, THE RESPONSIBILITY FOR PROPERLY MAINTAINING A NOT ACCEPT ANY RESPONSIBILITY FOR THESE ELEMENTS. THE FIRE SPRINKLER WATER BASED FIRE PROTECTION SYSTEM SHALL BE THAT OF THE OWNER, IF THE ENGINEER IS ONLY RESPONSIBLE FOR THOSE PORTIONS OF THE FIRE SPRINKLER BUILDING OWNER HAS NOT RECEIVED A COPY OF THIS PAMPHLET AND/OR IS NOT DRAWINGS DEPICTING FIRE SPRINKLER SCOPES OF WORK, REFER TO APPROVED FAMILIAR WITH THE OPERATION AND MAINTENANCE OF THIS SYSTEM, PLEASE CONTACT ARCHITECTURAL, STRUCTURAL, MEP OR CIVIL DRAWINGS FUR AUTHORITATIVE THE NEAREST OFFICE OF WAYNE AUTOMATIC FIRE SPRINKLERS, INC. EXPRESSIONS OF BACKGROUND INFORMATION THAT MAY BE UTILIZED IN FIRE HAZARD CLASS SPRINKLER DRAWINGS OR DETAILS 4 / CONSTRUCTION TYPE, CPVC COMPArPIBILYPY NOTICE # OF SPRINKLERS IN CPVC FIRE SPRINKLER PIPING SYSTEMS HAVE BEEN USED SUCCESSFULLY FOR MORE THAN 20 YEARS IN NEW CONSTRUCTION, RE -PIPE AND REPAIR. CPVC PRODUCTS ARE CONCORD, NC 4370 MOTORSPORT DRIVE CONCORD, NC 28027-8977 PHONE (704) 782-3ME! FAX: (704) 795-6836 IDEALLY SUITED FOR THESE APPLICATIONS DUE TO THEIR OUTSTANDING CORROSION :SIDUAL PRESSOR RESISTANCE OCCASIONALLY, HOWEVER, CPVC CAN BE DAMAGED BY CONTACT WITH CHEMICALS FOUND 1N SOME CONSTRUCTII]N MATERIALS (IE- SOME WIRES, FLUX, MINIMUM DENSITY PETROLEUM BASED PRODUCTS, ETC.) AND ANCILLARY PRODUCTS SUCH AS THREAD 1010 GPM - SEALANTS, LEAK DETECTORS, FIRESTUPS, ETC. ANY PRODUCT THAT COMES IN TIME OF TEST 8:00 AM CONTACT WITH CPVC SPRINKLER PIPE MUST BE EVALUATED IN ACCORDANCE WITH JUT READING THE SYSTEM COMPATIBILITY PROGRAM AS FUUND AT WWW.SYSTEMCOMPATIBLE.COM NUMBER OF PORTS FLOWED 1 COF'YRIa1-1 u, ALL DOCUMENTS, INCLUDING ORIGINAL DRAWINGS, SPECIFICATIONS, FIELD NOTES, GPM REQ'D 8 BW ESTIMATES AND DATA, INCLUDING COMPUTER PROGRAMS PURSUANT TO THIS PROJECT WAYNE AUTOMATIC FIRE SPRINKLERS, INC. ARE AND WILL REMAIN THE PROPERTY OF WAYNE AUTOMATIC FIRE SPRINKLERS, INC. (WAFS) AS INSTRUMENTS OF SERVICE, THEY ARE NOT INTENDED, NOR REPRESENTED GPM REQ D 2 HYD TU BE SUITABLE FOR RE -USE BY THE CLIENT, OR OTHERS, ON EXTENSION OF THIS PROJECT, OR FUR ANY OTHER PROJECT. ANY REUSE, OR ADAPTATION OF THE NFORMATION CONTAINED HEREIN, WITHOUT SPECIFIC WRITTEN PERMISSION FROM WAFS SPRINKLER WILL DE AT THE CLIENTS SOLE RISK, WITHOUT LIABILITY, UR LEGAL EXPOSURE TO WAFS, AND WILL ENTITLE WAFS TO FURTHER COMPENSATION AT RATES TO BE ]CATION OR AGREED ON BETWEEN WAFS AND THE CLIENT. THE CLIENT SHALL ALSO INDEMNIFY INSIDE/wrslDE AND HULD WAFS HARMLESS FROM ANY AND ALL CLAIMS, DAMAGES, LOSSES "I') EXPENSES, INCLUDING ATTORNEYS FEES RESULTING FROM ANY SUCH PERMISSIONS. WATERUPP S LY IN I N INFORMATION DRAWN BY, MICKEY FERGUSON DROUGHT OR FIRE PUMP SYSTEM DESIGN - -..--OILMAIN ACTUAL EXTRAPOLATED BY AREA # IE � � CONTRACT # (AS REQ'D BY AHI SIZE, GPM R PSI HAZARD CLASS [ATIC PRESSI.RE 66 PSI CONSTRUCTION TYPE, HYDRANT ELEV, 2' # OF SPRINKLERS IN FT. MYERS, FL 4683 LAREDO AVE FT. MYERS, FL 33905-4924 PHONE (239) 433-3030 FAX: (239) 433-3253 CONCORD, NC 4370 MOTORSPORT DRIVE CONCORD, NC 28027-8977 PHONE (704) 782-3ME! FAX: (704) 795-6836 DESIGN AREA :SIDUAL PRESSOR 56 PSI DATE OF TEST 09/06/16 MINIMUM DENSITY -OW IN GPM 1010 GPM TIME OF TEST 8:00 AM DESIGN AREA SF, JUT READING 36 PSI NUMBER OF PORTS FLOWED 1 PSI REQ'D a BW GPM REQ'D 8 BW ST PROVIDED BY WAYNE AUTOMATIC FIRE SPRINKLERS, INC. PSI REWD R HYD GPM REQ D 2 HYD ELEVATION R HIGHEST SPRINKLER YDRANT HOSE ]CATION OR TEST HYDRANT LOCATED ON WHITE CEDAR ROAD INSIDE/wrslDE UMBER DOMESTIC DEMAND DESIGN CRITERIA SPRINKLERS SPACING, SYMBOL MAXIMUM MINIMUM COMMENTS f- L S QUANTITY SPRINKLERS 1ST PND I I SIN ISIZE ITEMPI MODEL TOTAL PER FLOOR TOTAL PER UNIT TOTAL THIS SHEET DATE SUBMMALS 09/13/16 QA REVIEW BY MPF LOTS 64-69 r THO RHES ROOKE TW 0 NHOM ES WHITE CEDAR ROAD )ANFORD FL 32771 WWAYNE TAYLOR MORRISON HOMES 151 SOUTHHALL LANE, SUITE 200 Automatic Fire Sprinklers Inc MAITI AND, FL 32751 4NELT TITLE, FIRE SPRINKLER DETAILS DRAWN BY, MICKEY FERGUSON OFFICE - ORLANDO, FLORIDA ---- - - 110 - -..--OILMAIN DATE, NO. DATE REVISIONS BY 222 CAPITOL COURT OCOEE, FLORIDA 34761 PHONE: (407) 555-3030 FAX: (407) 658-6026 IE � � CONTRACT # 84196 JACKSONVL.LE FL 11326 DISTRIBUTION AVE WEST JACKSONVILLE. FL 32256-2745 PHONE (904) 268-3030 FAX (904) 268-0724 TAMPA, FL 3226 CHERRY PALM DRIVE TAMPA. FL 33619-8337 PHONE: (813) 630-0303 FAX: (813) 630-0312 POMPANO BEACH, FL 3121 NW 16TH TERRACE POMPANO BEACH, FL 33064-1408 PHONE: (864) 917-3030 FAX: (954) 911 r CONSTRUCTION TYPE, OCCUPANCY R-3 FT. MYERS, FL 4683 LAREDO AVE FT. MYERS, FL 33905-4924 PHONE (239) 433-3030 FAX: (239) 433-3253 CONCORD, NC 4370 MOTORSPORT DRIVE CONCORD, NC 28027-8977 PHONE (704) 782-3ME! FAX: (704) 795-6836 STATE LICENSES: NC SPRINKLER; 29745 NO ALARM: 29222 SP LV SC SPRINKLER: 1116 SC ALARM; 3385 4NELT TITLE, FIRE SPRINKLER DETAILS DRAWN BY, MICKEY FERGUSON TOTAL A/S, 110 DATE, SEPTEMBER 12, 2016 AHJ CITY OF SANFORD CONTRACT # 84196 CENTER OF TILE JOB? ❑ YES NO I CENTER ON FIXTURES JOB? ❑ YES NO SHEET # r CONSTRUCTION TYPE, OCCUPANCY R-3 Storage II No_4/S Lj Lanai No A/S Family Rood 9'-4' Mg. • ICY a _ �ooa � Cafe /x\ 9'-4" Clg, 0_14•6f It � -4" Clg, ® i LY1 p4t­4 B!,i0'_-L 11 -n -t 43 Sq Ft__ --- 9'-4' CIO, 0 0- q Ft sp II No S CIO 4-fOor— o��� 0 9'-�Clg,- — 0 n 100 MAXIMUM Garage 2ND FLOOR ® 1616' U.N.O.SPRINKLERS S' BETWEEN No A/S ~ ' CONSTRUCTION TYPE, V_B 9'-4' Clg, I1�I I I BIRCH UNIT FIRE PROTECTION PLAN 1v1 I I I Int Ir 11 11 SCALE 1/4' = V (1,832 SVR. FT.) I) L_ t�r�S� \ of x S� ��� T��� ELE vIEN rs NC7TE FIRE DRAWINGS AND SHOP DRAWINGS MAY INCLUDE WATER SUPPLY INFORMATION r-01�� �I\ Max, DESIGN CRITERIA �. • 1 • 1 SPRINKLER CONSTRUCTION W i i" f AL CIVIL BACKGROUND llRAWlNGS OR GRAPHICS BORROWED FROM IRE ARChITEC UR , \ In -6WH 2n 9'-4' C 1 8'-4' Clg, I a Porch No A/S DESIGN AREA, #13-1 END FLOOR UNIT B HALLWAY 1COMPARTMENT DESIGN PER NFPA I= 2010 EDITION, SECTION 8.1.5 B1 16' X 16' SPACING 13,0 GPM @ 7,0 PSI O16' X 16' SPACING 13.0 GPM @ 7,0 PSI WN „,. 00853N DESIGN AREA #B-2 END FLOOR UNIT B OWNER'S SUITE COMPARTMENT DESIGN PER NFPA IM, 2010 EDITION, SECTION BAR B3 20' X 20' SPACING 20,0 GPM @ 16.7 PSI B4 16' X 16' SPACING \V� 13.0 GPM @ 7.0 PSI A.t` `E. -tk 00853N SPRINKLERS SPACING SYMBOL MAXIMUM IST FLOOR 2ND FLOOR ® 1616' U.N.O.SPRINKLERS S' BETWEEN 2' 1' 0 4'8' SHEET # F . 1 CONSTRUCTION TYPE, V_B occuPANCY� R-3 I I BIRCH UNIT FIRE PROTECTION PLAN SCALE 1/4' = V (1,832 SVR. FT.) TMI1?01,I'ANr' a WNER INF'O_RMA'I'IOl1T ��� T��� ELE vIEN rs NC7TE FIRE DRAWINGS AND SHOP DRAWINGS MAY INCLUDE WATER SUPPLY INFORMATION DESIGN CRITERIA THIS DRAWING IS BASED ON THE OWNER'S ACCEPTANCE OF THE CURRENTLY ADOPTED SPRINKLER CONSTRUCTION W i i" f AL CIVIL BACKGROUND llRAWlNGS OR GRAPHICS BORROWED FROM IRE ARChITEC UR , EDITION (EITHER STATE OR LOCAL) OF NFPA 25 AS THE APPLICABLE STANDARD FOR THE INSPECTION, TESTING AND MAINTENANCE OF WATER BASED FIRE PROTECTION STRUCTURAL, OR MEP DRAWINGS. THESE REFERENCE BACKGROUND ELEMENTS ARE FOR GENERAL INFURMANON OR CONTEXT ONLY AND THE FIRE SPRINKLER ENGINEER DOES DROUGHT OR FIRE PUMP SYSTEM/ DESIGN AREA f B -I B-2 SYSTEMS. PER SECTION 41, THE RESPONSIBILITY FOR PROPERLY MAINTAINING A NGT ACCEPT ANY RESPONSIBILITY FOR THESE ELEMENTS. THE FIRE SPRINKLER ACTUAL EXTRAPOLATED WATER BASED FIRE PROTECTION SYSTEM SHALL BE THAT OF THE OWNER, IF THE BUILDING OWNER HAS NOT RECEIVED A COPY OF THIS PAMPHLET AND/UR IS NOT ENGINEER IS ONLY RESPONSIBLE FOR THOSE PORTIONS OF THE FIRE SPRINKLER DRAWINGS DEPICTING FIRE SPRINKLER SCOPES OF WORK. REFER TO APPROVED (AS REQ'D BY ABU) SIZE, GPM @PSI HAZARD CLASS NFPA 13D NFPA 13D FAMILIAR WITH THE OPERATION AND MAINTENANCE OF THIS SYSTEM, PLEASE CONTACT THE NEAREST OFFICE GF WAYNE AUTOMATIC FIRE SPRINKLERS, INC.. ARCHITECTURAL, STRUCTURAL, MEP OR CIVIL DRAWINGS FGR AUTHORITATIVE EXPRESSIONS OF BACSPRINKLRIKL ERDRAWINGS OR DETAILS INFORMATION THAT MAY BE UTILIZED IN FIRE STATIC PRESSURE URE 66 PSI HYDRANT ELEV,. 2'. # QE sPRINKLERs IN 2 2 . DESIGN AREA - - RESIDUAL PRESSURE 56 PSI DATE OF TEST 09/06/16 1 MINIMUM DENSITY GPVG CONIPATIE3ILITY NOTICE .05 .05 CPVC FIRE SPRINKLER PIPING SYSTEMS HAVE BEEN USED SUCCESSFULLY FOR MORE THAN 20 'FEARS IN NEW CONSTRUCTION, RE-PtP% AND REPAIR, CPVC PRODUCTS ARE II FLOW IN GPM 1010 GPM TIME OF TEST Boo AM II DESIGN AREA Sf. 2 SPRKS 2 SPRKS IDEALLY SUITED FOR THESE APPLICATIONS DUE TO THEIR OUTSTANDING CORROSII]N RESISTANCE, OCCASIONALLY, HOWEVER, CPVC CAN BE DAMAGED BY CONTACT WITH I PITOT READING 36 PSI NUMBER OF PORTS FLOWED 1 PSI REQ'D @ BB 27,0 43,3 �I CHEMICALS FOUND IN SOME CONSTRUCTION MATERIALS (IE, SOME WIRES, FLUX, PETROLEUM BASED PRODUCTS, ETC.) AND ANCILLARY PRODUCTS SUCH AS THREAD SEALANTS, LEAK DETECTORS, FIRESTUPS, ETC, ANY PRODUCT THAT COMES IN CONTACT WITH CPVC SPRINKLER PIPE MUST BE EVALUATED IN ACCORDANCE WITH - ii - GPM REQ'D @ DB 26,3 403 THE SYSTEM COMPATIBILITY PROGRAM AS -FOUND AT WWW.SYSTEMCOMPATIBLE COM TEST PROVIDED BY WAYNE AUTOMATIC FIRE SPRINKLERS, INC, PSI REQ'D e HYD 36,7 56,4 C O P YFZ C G I I T FIELD NOTES, GPM REQ'D @ HYD 31.3 45,9 11 iiESTIMATES ALL DOCUMENTS, INCLUDING ORIGINAL DRAWINGS, SPECIFICAYIUNS, AND DATA, INCLUDING COMPUTER PROGRAMS PURSUANT TO THIS PROJECT ARE AND WILL REMAIN THE PROPERTY OF WAYNE AUTOMATIC FIRE SPRINKLERS, INC ! I' ELEVATION @ HIGHEST n p 1T_9' 19'-8' l V N + (WAFS) AS INSTRUMENTSOFSERVICE. THEY ARE NOT INTENDED, NOR REPRESENTED SPRINKLER TO BE SUITABLE FOR RE -USE BY THE CLIENT, OR OTHERS, ON EXTENSION OF THIS HOSE O nH PROJECT, OR FOR ANY OTHER PROJECT. ANY REUSE, OR ADAPTATICN OF THE NFURMATIGN CONTAINED HEREIN, WITHOUT SPECIFIC WRITTEN PERMISSION FROM WAFS I' �d HYDRANTN/A LOCATION OR TEST HYDRANT LOCATED ON WHITE CEDAR ROAD INSIDEAUTSIDE N/A " WILL BE AT THE CLIENTS SOLE RISK, WITHOUT LIABILITY, OR LEGAL EXPOSURE TO WAFS TO T AT RATES AND F'WAFS I; NUMBER DOMESTIC DEMAND f 5 GPM 5 GPM THE CLIENT ALSO INDEION AND THE CLIENTITI.E A REED OND rWEENMfN1 FY C� AND HOLD WAFS HARMLESS FROM ANY AND ALL CLAIMS, DAMAGES, LOSSESAND ` EXPENSES, INCLUDING ATTORNEYS FEES RESULTING FROM ANY SUCH PERMISSIONS. m r-1 rn DESIGN AREA, #13-1 END FLOOR UNIT B HALLWAY 1COMPARTMENT DESIGN PER NFPA I= 2010 EDITION, SECTION 8.1.5 B1 16' X 16' SPACING 13,0 GPM @ 7,0 PSI O16' X 16' SPACING 13.0 GPM @ 7,0 PSI WN „,. 00853N DESIGN AREA #B-2 END FLOOR UNIT B OWNER'S SUITE COMPARTMENT DESIGN PER NFPA IM, 2010 EDITION, SECTION BAR B3 20' X 20' SPACING 20,0 GPM @ 16.7 PSI B4 16' X 16' SPACING \V� 13.0 GPM @ 7.0 PSI A.t` `E. -tk 00853N SPRINKLERS SPACING SYMBOL MAXIMUM MINIMUM COMMENTS ® 1616' U.N.O.SPRINKLERS S' BETWEEN 8`4 MAX SPACING OFF WALL U.N.O. DEFLECTOR 10 BE INSTALLED 14-44 BELOW CEILING SHEET # F . 1 CONSTRUCTION TYPE, V_B occuPANCY� R-3 * DESIGN AND INSTALLATION TO BE IN ACCORDANCE WITH 2010 EDITION OF NFPA 130. • DESIGN AND INSTALLATION TO BE IN ACCORDANCE WITH ALL APPLICABLE LOCAL AND STATE CODES. * ALL PIPE AND FITTINGS USED ON THIS PROJECT TO BE IN ACCORDANCE WITH APPLICABLE CODES AND WAFS STANDARDS. SEE PIPE AND FITTINGS GENERAL NOTES (WAFS DETAIL #00593N). �` * ALL HANGERS SHALL BE DESIGNED AND INSTALLED IN ACCORDANCE WITH NFPA 130 AND 'THEIR LISTING. TO SPRINKLER SYSTEM • ALL PENETRATIONS THROUGH RATED BUILDING ASSEMBLIES SHALL BE SEALED WITH FIRE CAULK IN SEE UNIT PLANS FOR CONTINUATION ACCORDANCE WITH DETAILS PROVIDED, WAFS POLICY IS TO USE HILTI FS ONE OR STI LCI. IT * UNDERGROUND MAINS AND LEAD-INS SHALL BE FLUSHED AND SIGNED TEST CERTIFICATES PROVIDED 6' 120VAC BELL W/WEATHERPROOF BACK BEFORE A CONNECTION IS MADE TO THE SPRINKLER SYSTEM. BOX LOCATE ON OUTSIDE WALL OF WOOD FLOOR TRUSS * WHEN SYSTEM IS FED USING PLUMBING SERVICE, PIPING SHALL STILL BE FLUSHED PRIOR TO CONNECTING THE SPRINKLER SYSTEM. BUILDING (WIRED $Y OTHERS) _"y • ALL PIPING SHALL BE INSPECTED AND APPROVED BY PROPER AUTHORITIES PRIOR TO COVERING WITH DRYWALL. COPIES OF SIGNED TEST CERTIFICATES ARE TO BE FORWARDED TO THE PROPER RECIPIENTS, f- 3' SPLIT RING HANGER * ALL SYSTEMS SHALL BE TESTED AT 200 PSI FOR 2 HOURS PER WAFS STANDARDS. 3/8' A T;R, & HILTI DROP-IN ANCHOR • ALL SOFFITS REQUIRED TO CONCEAL SPRINKLER PIPING ARE BY OTHERS. * ALL WIRING OF DEVICES IF PROVIDED (FLOW SWITCHES, TAMPER SWITCHES, ETC) IS BY OTHERS. > • VALVES SHALL NOT BE REQUIRED TO BE MONITORED PER FLORIDA BUILDING CODE 903.4 (1). 14' X 114' X VCPVC REDUCING TEE-- LOCAL EQUIPPED APROVIDEDTERFLbW ALARMS SHALL BE, HOMES WITH SMOKE ALARMS OR SMOKEDETECT RS N ACCORDANCE WITH NFPA 772,NATIONAL FIRE NO SPARE SPRINKLERS ALARM CODE. 114' x 3' x CPVC REDUCING TEE W/ REQUIRED PER NFPA 13D * CONNECTION OF SPRINKLER DEVICES TO THE BUILDING ALARM OR MONITORING SYSTEM, IF PROVIDED, IS ' x 1 ' CPVC SPIG ADAPTER--`"— BY OTHERS. GALV, PLUG AND 300 PSI WATER GAUGE * ALL PAINTING OF PIPE AS REQUIRED IS BY OTHERS. & 3 -WAY VALVE * ALL INSULATION REQUIRED FOR FREEZE PROTECTION OF SPRINKLER PIPING IS BY OTHERS. • HEATING OF ROOMS TO MAINTAIN TEMPERATURES OF 40 DEGREES OR GREATER IS BY OTHERS. • SPRINKLERS SHALL NOT BE INSTALLED PRIOR TO THE FITTINGS BEING CEMENTED IN PLACE. 3'xI%'xl' CPVC REDUCING TEE—'- • ALL SPRINKLERS IN DWELLING UNITS SHALL BE UL LISTED OR FM APPROVED RESIDENTIAL SPRINKLERS. W/POTTER GLUE IN FLOW SWITCH • SPARE SPRINKLERS WILL NOT BE PROVIDED AS THEY ARE NOT REQUIRED BY NFPA 131). (WIRED BY OTHERS) CPVC BALL VALVE * REFER TO SPACING NOTES ON PLANS FOR MAXIMUM CALCULATED SPACING ALLOWANCES. 1 • SPRINKLERS SHALL BE INSTALLED IN ALL AREAS EXCEPT AS FOLLOWS: o BATHROOMS WHERE THE AREA DOES NOT EXCEED 55 SQ FT. 1f' CPVC CHECK VALVE--'--" o CLOTHES CLOSETS, LINEN CLOSETS AND PANTRIES WITHIN THE DWELLING UNITS THAT 00 NOT EXCEED 24 SQUARE FEET, THE LEAST DIMENSION DOES NOT EXCEED 3 FEET, AND THE WALLS AND CEILINGS ARE SURFACED WITH NONCOMBUSTIBLE OR LIMITED -COMBUSTIBLE MATERIALS AS DEFINED > BY NFPA 220, STANDARD ON TYPES OF BUILDING CONSTRUCTION. 7 C1 o ANY GARAGES, OPEN ATTACHED PORCHES, CARPORTS AND SIMILAR STRUCTURES. o ATTICS, PENTHOUSE EQUIPMENT ROOMS, ELEVATOR MACHINE ROOMS, CONCEALED SPACES DEDICATED 11 ' COUP & 11¢'X1 ' EXCLUSIVELY TO AND CONTAINING ONLY DWELLING UNIT VENTILAION EQUIPMENT, FLOOR/CEILING CPVC BUSHING SPACES, ELEVATOR SHAFTS, CRAWL SPACES, AND OTHER CONCEALED SPACES THAT ARE NOT USED OR INTENDED FOR LIVING PURPOSES AND DO NOT CONTAIN FUEL -FIRED EQUIPMENT. o COVERED UNHEATED PROJECTIONS OF THE BUILDING AT ENTRANCES/EXITS AS LONG AS THERE IS Bx V CPVC 90' OUT WALL ANOTHER MEANS OF EGRESS FROM THE DWELLING UNIT, TO %'A' SPIGOT ADAPTER o SPRINKLERS SHALL NOT BE REQUIRED FOR CEILING POCKETS THAT MEET THE FOLLOWING CONDITIONS: 1. THE TOTAL VOLUME OF UNPROTECTED CEILING POCKET DOES NOT EXCEED 100 CU. FT. OVERHEAD PERMIT T® & SAWN HEAD 2. THE ENTIRE FLOOR UNDER THE UNPROTECTED CEILING POCKET IS PROTECTED BY THE SPRINKLERS START AT �,-®� A.R.F. AT THE LOWER CEILING ELEVATION. 3. EACH UNPROTECTED CEILING POCKET IS SEPARATED FROM ANY ADJACENT UNPROTECTED CEILING a POCKET BY A MINIMUM OF 10 FT. HORIZONTAL DISTANCE, 4, THE INTERIOR FINISH OF THE UNPROTECTED CEILING POCKET IS NONCOMBUSTIBLE OR LIMITED -COMBUSTIBLE MATERIAL. 5. SKYLIGHTS NOT EXCEEDING 32 SQ. FT. SHALL BE PERMITTED TO HAVE A PLASTIC COVER. L - WAFS TO PROVIDE ALL REQUIRED SIGNAGE PER NFPA 130 INCLUDING BUT NOT LIMITED TO VALVES, DYNAFLOW SLEEVE -----HYDRAULIC PLACARDS, AND INSPECTION TAGS AS REQUIRED BY FS 633, DEVICES THAT RESTRICT THE FLOW OR DECREASE THE PRESSURE OR AUTOMATICALLY SHUT OFF THE FROM SUPPLY 1 1/2' PIPE ROTATED FOR CLARITY WATER TO THE SPRINKLER SYSTEM, SUCH AS WATER SOFTENERS, FILTRATION SYSTEMS, AND BY OTHERS AUTOMATIC SHUTOFF VALVES, SHALL NOT BE ADDED TO THIS SYSTEM WITHOUT A REVIEW OF THE CPVC FIRE SPRINKLER SYSTEM BY A FIRE PROTECTION SPECIALIST. TYPICAL EXPOSE® CPVC FIRE SPRINKLER RISER r NFPA 130 2010 GENERAL NOTES 0—k\"8M/Mr� SCALEI NONE AE SCALEI NONE Automatic Fire Sprinklore, Inc. Auto tic F" moo. km 00678N TYPICAL ` - TYPICAL LIGHT Sf SPRINKLER FIXTURE 36' MINIMUM'S IN ROOMS/COMPARTMENTS 400 CU, FT, OR LESS, (ANY MODEL IS ACCEPTABLE SPRINKLERS MAY BE PLACED REGARDLESS OF PROVIDED PLAN VIEW OF LOCATION OF OBSTRUCTIONS, BLADES IS 50% OPEN) NFPA 13R G 13® NFPA 13R Er 13D SPRINKLER CLEARANCE W/ LIGHT FIXTURE SPRINKLER CLEARANCE W/ CEILING FAN V q- AIfNE SCALEI NONE AYNE Automatic Fire Sprinklers, Inc. (1H5fl4N Automatic Fire Sprinklere, Inc. r--QUANTITY--i SPRINKLERS YMB 1ST 2ND 3RD 4TH SIN SIZE K TEMP MODEL 8 11 R3516 4.9 155' RELIAE WHITE 1 0 R3516 4.9 175 RELIAE � � WHITE 9111 TOTAL PER FLOOR 20 TOTAL PER UNIT 20 TOTAL THIS SHEET DATE SUBMI`1'I'AIS 09/13/16 QA REVIEW NO. DATE I REVISIONS Ai r K SCALE: NONE 00505N W R R W Willow Redwoo Redwood Willow 65 64 69 68' BY II, i MPF IIS WA"E Automatic Fire Sprinklers, Inc. - MAIN OFFICE — ORLANDO, FLORIDA BY 222 CAPITOL COURT OCOEE, FLORIDA 34751 PHONE: (407) 558-3030 FAX: (407) 558-9025 �E JACKSONVLLE, FL 7 TAMPA, FL PUMPANO BEACH. FL 11326 DISTRIBUTION AVE WEST 3226 CHERRY PALM DRIVE 3121 NW 16TH TERRACE JACKSONVILLE. FL 32256-2745 TAMPA, FL 33619-8337 POMPANO BEACH, FL 33064-1408 PHONE 19041 268-3030 PHONE: (813) 630-0303 PHONE: (954) 917-3030 FAX: (904) 268-0724 FAX: (813) 630-0312 FAX: (954) 9T7 - FT. MYERS, R =4GDREII. NC STATE LICENSES: 4883 LAREDO AVE 4370 MOTORSPORT DRIVE NO SPRINKLER: 29745 FT. MYERS. FL PHONE (238) 433- 3030 4 CONCORD. PHONE (704)288230327 NO SCO S RINKLER 1 29222 116P LV FAX: (239) 433-3263 FAX: (704) 795-8838 SC ALARM: 3385 LOTS 64-69 TH R S0 - E T OWNHO NE ROOKMES WHITE CEDAR ROAD SANFORD FL 32771 TAYLOR MORRISON HOMES 151 SOUTHHALL LANE, SUITE 200 MAITLAND, FL 32751 SHEET TITLE, BIRCH UNIT FIRE SPRINKLER LAYOUT DRAWN BY, MICKEY FERGUSON TOTAL nisi 110 DATE- SEPTEMBER 12, 2016 AHJ, CITY OF SANFORD CONTRACT 1 84196 CENTER OF TILE J0137 EjYESNO CENTER ON FIXTURES. JOB? [:]YES NO SHEET # F . 1 CONSTRUCTION TYPE, V_B occuPANCY� R-3 I F DESIGN AREA#R-1 IST FLOOR UrgT R FAMILY ROOM COMPARTMENT DESIGN PER NFPA 130, 2010 EDITION, SECTION 8.1.2 R1 20' X 20' SPACING 20.0 GPM @ 16,7 PSI R2 20' X 20' SPACING 20.0 GPM @ 16.7 PSI A\ `WAYNE 00853N 2' 1' 0 4' U' SCALE 1/4' = V 1ST FLOOR 2ND FLOOR REDWOOD UNIT FIRE PROTECTION PLAN (1,943 SQ. FT.) INIPOE2I'A'NI' OWNER INF'ORiVI��.'I'ION C}RAFHIC:�� FL�'IVI�N'I':� NO'I'�',,, FIR SPRINKLER CONSTRUCTION DRAWN N E L 1 DRAWINGS AND SHOP DRAWINGS MAY IAL CIE WATER SUPPLY THIS DRAWING IS BASED ON THE OWNER'S ACCEPTANCE OF THE CURRENTLY ADOPTED BACKGROUND DRAWINGS OR GRAPHICS BORROWED FROM THE ARCHITECTURAL CIVIL INFORMATION DESIGN CRITERIA ACTUAL EDITION (EITHER STATE DR LOCAL) OF NFPA 27 AS THE FlPPLICFlBLE STANDARD FORSTRUCTURAL, OR MEP DRAWINGS. THESE REFERENCE BACKGROUND ELEMENTS ARE FOR SIZE, GPM @ PSI THE INSPECTION, TESTING AND MAINTENANCE OF WATER BASED FIRE PROTECTION GENERAL INFORMATION OR CONTEXT ONLY AND THE FIRE SPRINKLER ENGINEER DOES 66 PSI MAXIMUM SYSTEMS, PER SECTION 41, THE RESPONSIBILITY FUR PROPERLY MAINTAINING A NOT ACCEPT ANY RESPONSIBILITY FOR THESE ELEMENTS. THE FIRE SPRINKLER RESIDUAL PRESSURE 56 PSI WATER BASED FIRE PROTECTION SYSTEM SHALL BE THAT OF THE OWNER, IF THE ENGINEER IS ONLY RESPONSIBLE FOR THOSE PORTIONS OF THE FIRE SPRINKLER 09/06/16 FLOW IN GPM BUILDING OWNER HAS NOT RECEIVED A COPY OF THIS PAMPHLET AND/OR IS NOT DRAWINGS DEPICTING FIRE SPRINKLER SCOPES OF WORK, REFER TO APPROVED TIME OF TEST HO AM FAMILIAR WITH THE OPERATION AND MAINTENANCE OF THIS SYSTEM, PLEASE CONTACT ARCHITECTURAL, STRUCTURAL, MEP OR CIVIL DRAWINGS FOR AUTHORITATIVE NUMBER OF PORTS FLOWED I 'THE NEAREST OFFICE OF WAYNE AUTOMATIC FIRE SPRINKLERS, INC. EXPRESSIONS OF BACKGROUND INFORMATION THAT MAY BE UTILIZED IN FIRE HYDRANT LOCATION OR NUMBER TEST HYDRANT LOCATED ON WHITE CEDAR ROAD 155 . SPRINKLER DRAWINGS OR DETAILS 42,1 U.N.O. i DEFLECT T INSTALLED p � OR 0 BE IN TA LED 1-4 BELOW CEILING PSI REQ'D @ HYD 55,1 TAMPA, FL 33619-8337 PHONE. (813) 630-0303 POMPANO BEACH, FL 33064-1408 PHONE: (954) 917-3030 CONTRACT # �� �� CPVC CONIPATIBILITY NOTIC-E, 47,1 WHITE W/ RECESSE ® CPVC FIRE SPRINKLER PIPING SYSTEMS HAVE BEEN USED SUCCESSFULLY FOR MORE ELEVATION @ HIGHEST SPRIKER 9'-4' SET # THAN 20 YEARS IN NEW CONSTRUCTION, RE -PIP% AND REPAIR, CPVC PRODUCTS ARE 175 , NSE S DE/OUTSIDE N/A IDEALLY SUITED FOR THESE APPLICATII]NS DUE TO THEIR OUTSTANDING CORROSION FPRN 1 DOMESTIC DEMAND RESISTANCE, OCCASIONALLY, HOWEVER, CPVC CAN BE DAMAGED BY CONTACT WITH CHEMICALS FOUND IN SOME CONSTRUCTIDN MATERIALS (IE- SOME WIRES, FLUX, PETROLEUM BASED PRODUCTS, ETC.) AND ANCILLARY PRODUCTS SUCH AS 'THREAD SEALANTS, LEAK DETECTORS, FIRESTUPS, ETC. ANY PRODUCT THAT COMES IN CONTACT WITH CPVC SPRINKLER PIPE MUST BE EVALUATED IN ACCORDANCE WITH THE SYSTEM COMPATIBILITY PROGRAM AS FOUND AT WWW.SYSTEMCOMPATIBLE.CUM COPYIzIG FI11' ALL DOCUMENTS, INCLUDING ORIGINAL DRAWINGS, SPECIFICATIONS, FIELD NOTES, i. CL ESTIMATES AND DATA, INCLUDING COMPUTER PROGRAMS. PURSUANT TO THIS PROJECT n ARE AND WILL REMAIN THE PROPERTY OF WAYNE AUTOMATIC FIRE SPRINKLERS, INC. (WAFS) AS INSTRUMENTS OF SERVICE, THEY ARE NOT INTENDED, NOR REPRESENTED 00 TO BE SUITABLE FOR RE -USE BY THE CLIENT, OR OTHERS, ON EXTENSION OF THIS Q PROJECT, DR FOR ANY OTHER PROJECT, ANY REUSE, OR ADAPTATION OF THE NFORMATION CONTAINED HEREIN, WITHOUT SPECIFIC WRITTEN PERMISSION FROM WAFS N WILL BE AT THE CLIENTS SOLE RISK, WITHOUT LIABILITY, OR LEGAL EXPOSURE TO � WAFS, AND WILL ENTITLE WAFS TO FURTHER COMPENSATION AT RATES TO BE li ri AGREED ON BETWEEN WAFS AND THE CLIENT. THE CLIENT SHALL ALSO INDEMNIFY O AND HOLD WAFS HARMLESS FROM ANY AND ALL CLAIMS, DAMAGES, LOSSES AND ` EXPENSES, INCLUDING ATTORNEYS FEES RESULTING FROM ANY SUCH PERMISSIONS, DESIGN CRITERIA ACTUAL DROUGHT OR EXTRAPOLATED (AS REQ'D BY AHJ) FIRE PUMP SIZE, GPM @ PSI HAZARD CLASS STATIC PRESSURE 66 PSI MAXIMUM HYDRANT ELEV, 2' RESIDUAL PRESSURE 56 PSI 2ND DATE OF TEST 09/06/16 FLOW IN GPM 1010 GPM MODEL TIME OF TEST HO AM PITOT READING 36 PSI NUMBER OF PORTS FLOWED I TEST PROVIDED BY WAYNE AUTOMATIC FIRE SPRINKLERS, INC, HYDRANT LOCATION OR NUMBER TEST HYDRANT LOCATED ON WHITE CEDAR ROAD DESIGN CRITERIA SYSTEM / DESIGN R-1 SPRINKLERS T HORNEBROOKE TOWNHOMES OMES HAZARD CLASS NFPA 13D SYMBOL MAXIMUM MINIMUM # OF SPRINKLERS IN DESIGN AREA 2 IST 2ND SIN j MINIMUM DENSITY 05 TEMP MODEL Q DESIGN AREA SF, 2 SPRKS 8'-0" MAX SPACING OFF WALL U.N.O, s O 7 PSI REQ'D @ DR 39,9 DATE, SEPTEMBER 12, 2016 4,9 155 . GPM REQ'D @ BR 42,1 U.N.O. SPRINKLERS DEFLECT T INSTALLED p � OR 0 BE IN TA LED 1-4 BELOW CEILING PSI REQ'D @ HYD 55,1 TAMPA, FL 33619-8337 PHONE. (813) 630-0303 POMPANO BEACH, FL 33064-1408 PHONE: (954) 917-3030 CONTRACT # �� �� GPM REWD @ HYD 47,1 WHITE W/ RECESSE ® 1 ELEVATION @ HIGHEST SPRIKER 9'-4' SET # 4,9 175 , NSE S DE/OUTSIDE N/A FPRN 1 DOMESTIC DEMAND 5 GPM T2- - TO SPRINKLER SYSTEM � �T SEE. UNIT PLANS FOR CONTINUATION 6' 120VAC BELL W/WEATHERPROOF BACK x BOX LOCATE ON OUTSIDE WALL OFWOOD FLOOR TRUSS BUILDING (WIRED BY OTHERS) - -- - f- 3' SPLIT RING HANGER 3/8' A.T.R. & HILTI DROP-IN ANCHOR U CL- I%' 1%' X 3' X V CPVC REDUCING TEE- 1�' x IV x V CPVC REDUCING TEE W/ NO SPARE SPRINKLERS V x V CPVC SPIG ADAPTER----`- REQUIRED PER NEPA 13D GALV, PLUG AND 300 PSI WATER GAUGE & 3 -WAY VALVE 1%'xl'%'xl' CPVC REDUCING TEE W/POTTER GLUE IN FLOW SWITCH (WIRED BY OTHERS)CPVC BALL VALVE W CPVC CHECK VALVE-!� 1! , COUP & 1' 'XIV' CPVC BUSHING Bx V CPVC 90' OUT WALL /- TO VA' SPIGOT ADAPTER OVERHEAD PERMIT TO f & SAWN HEAD START AT 1'-®", A.E.E. DYNAFLOW SLEEVE----'[ FROM SUPPLY 1 1/2' PIPE ROTATED FOR CLARITY BY OTHERS CPVC TYPICAL EXPOSED CPVC FIRE SPRINKLER RISER r E. Fire Sprinklers, Inc. TYPICAL J TYPICAL LIGHT SPRINKLER FIXTURE SI 36' MINIMUM SCALE: NONE • DESIGN AND INSTALLATION TO BE IN ACCORDANCE WITH 2010 EDITION OF NEPA 130. • DESIGN AND INSTALLATION TO BE IN ACCORDANCE WITH ALL APPLICAULE LOCAL AND STATE CODES. ik ALL PIPE AND FITTINGS USED ON THIS PROJECT TO BE IN ACCORDANCE WITH APPLICABLE CODES AND WAFS STANDARDS. SEE PIPE AND FITTINGS GENERAL NOTES (WAFS DETAIL #00593N). • ALL HANGERS SHALL BE DESIGNED AND INSTALLED IN ACCORDANCE WITH NFPA 130 AND THEIR LISTING. • ALL PENETRATIONS THROUGH RATED BUILDING ASSEMBLIES SHALL BE SEALED WITH FIRE CAULK IN ACCORDANCE WITH DETAILS PROVIDED. WAFS POLICY IS TO USE HILTI FS ONE OR STI LCL • UNDERGROUND MAINS AND LEAD–INS SHALL BE FLUSHES) AND SIGNED TEST CERTIFICATES PROVIDED BEFORE A CONNECTION IS MADE TO THE SPRINKLER SYSTEM. • WHEN SYSTEM IS FED USING PLUMBING SERVICE, PIPING SHALL STILL BE FLUSHED PRIOR TO CONNECTING THE SPRINKLER SYSTEM. • ALL PIPING SHALL BE INSPECTED AND APPROVED BY PROPER AUTHORITIES PRIOR TO COVERING WITH DRYWALL. COPIES OF SIGNED TEST CERTIFICATES ARE TO BE FORWARDED TO THE PROPER RECIPIENTS. • ALL SYSTEMS SHALL BE TESTED AT 200 PSI FOR 2 HOURS PER WAFS STANDARDS. • ALL SOFFITS REQUIRED TO CONCEAL SPRINKLER PIPING ARE BY OTHERS. Ik ALL WIRING OF DEVICES IF PROVIDED (FLOW SWITCHES, TAMPER SWITCHES, ETC) IS BY OTHERS. • VALVES SHALL NOT BE REQUIRED TO BE MONITORED PER FLORIDA BUILDING CODE 903.4 (1). • LOCAL WATERFLOW ALARMS SHALL BE PROVIDED ON ALL SPRINKLER SYSTEMS IN HOMES NOT EQUIPPED WITH SMOKE ALARMS OR SMOKE DETECTORS IN ACCORDANCE WITH NFPA 72, NATIONAL FIRE ALARM CODE. • CONNECTION OF SPRINKLER DEVICES TO THE BUILDING ALARM OR MONITORING SYSTEM, IF PROVIDED, IS BY OTHERS. • ALL PAINTING OF PIPE AS REQUIRED IS BY OTHERS. • ALL INSULATION REQUIRED FOR FREEZE PROTECTION OF SPRINKLER PIPING IS BY OTHERS. Ik HEATING OF ROOMS TO MAINTAIN TEMPERATURES OF 40 DEGREES OR GREATER IS BY OTHERS. • SPRINKLERS SHALL NOT BE INSTALLED PRIOR TO THE FITTINGS BEING .CEMENTED IN PLACE. • ALL SPRINKLERS IN DWELLING UNITS SHALL BE UL LISTED OR FM APPROVED RESIDENTIAL SPRINKLERS. • SPARE SPRINKLERS WILL NOT BE PROVIDED AS THEY ARE NOT REQUIRED BY NFPA 130. • REFER TO SPACING NOTES ON PLANS FOR MAXIMUM CALCULATED SPACING ALLOWANCES. ill SPRINKLERS SHALL BE INSTALLED IN ALL AREAS EXCEPT AS FOLLOWS: o BATHROOMS WHERE THE AREA DOES NOT EXCEED 55 SQ FT. o CLOTHES CLOSETS, LINEN CLOSETS AND PANTRIES WITHIN THE DWELLING UNITS THAT DO NOT EXCEED 24 SQUARE FEET, THE LEAST DIMENSION DOES NOT EXCEED 3 FEET AND THE WALLS AND CEILINGS ARE SURFACED WITH NONCOMBUSTIBLE OR LIMITED–COMBUSTIBLE MATERIALS AS DEFINED BY NFPA 220, STANDARD ON TYPES OF BUILDING CONSTRUCTION. o ANY GARAGES, OPEN ATTACHED PORCHES, CARPORTS AND SIMILAR STRUCTURES. o ATTICS, PENTHOUSE EQUIPMENT ROOMS, ELEVATOR MACHINE ROOMS, CONCEALED SPACES DEDICATED EXCLUSIVELY TO AND CONTAINING ONLY DWELLING UNIT VENTILAION EQUIPMENT, FLOOR/CEILING SPACES, ELEVATOR SHAFTS, CRAWL. SPACES, AND OTHER CONCEALED SPACES THAT ARE NOT USED OR INTENDED FOR LIVING PURPOSES AND DO NOT CONTAIN FUEL–FIRED EQUIPMENT. o COVERED UNHEATED PROJECTIONS OF THE BUILDING AT ENTRANCES/EXITS AS LONG AS THERE IS ANOTHER MEANS OF EGRESS FROM THE DWELLING UNIT. o SPRINKLERS SHALL NOT BE REQUIRED FOR CEILING POCKETS THAT MEET THE FOLLOWING CONDITIONS: 1. THE TOTAL VOLUME OF UNPROTECTED CEILING POCKET DOES NOT EXCEED 100 CU. FT. 2. THE ENTIRE FLOOR UNDER THE UNPROTECTED CEILING POCKET IS PROTECTED BY THE SPRINKLERS AT THE LOWER CEILING ELEVATION. 3. EACH UNPROTECTED CEILING POCKET IS SEPARATED FROM ANY ADJACENT UNPROTECTED CEILING POCKET BY A MINIMUM OF 10 FT. HORIZONTAL DISTANCE, 4. THE INTERIOR FINISH OF THE UNPROTECTED CEILING POCKET IS NONCOMBUSTIBLE OR LIMITED–COMBUSTIBLE MATERIAL, 5. SKYLIGHTS NOT EXCEEDING 32 SQ. FT. SHALL BE PERMITTED TO HAVE A PLASTIC COVER. • WAFS TO PROVIDE ALL REQUIRED SIGNAGE PER NFPA 130 INCLUDING BUT NOT LIMITED TO VALVES, HYDRAULIC PLACARDS, AND INSPECTION TAGS AS REQUIRED BY FS 633. • DEVICES THAT RESTRICT THE FLOW OR DECREASE THE PRESSURE OR AUTOMATICALLY SHUT OFF THE WATER TO THE SPRINKLER SYSTEM, SUCH AS WATER SOFTENERS, FILTRATION SYSTEMS, AND AUTOMATIC SHUTOFF VALVES, SHALL NOT BE ADDED TO THIS SYSTEM WITHOUT A REVIEW OF THE FIRE SPRINKLER SYSTEM BY A FIRE PROTECTION SPECIALIST. AIA E P" Sprkk". ho. 'IN ROOMS/COMPARTMENTS 400 CU, FT. OR LESS, CEILING FAN � SPRINKLERS MAY BE PLACED REGARDLESS OF (ANY MODEL IS ACCEPTABLE LOCATION OF OBSTRUCTIONS, PROVIDED PLAN VIEW OF BLADES IS 507 OPEN) NFPA 13R O 130NFPA 13R D 130 SPRINKLER CLEARANCE W/ LIGHT FIXTURE SPRINKLER CLEARANCE W/ CEILING FAN LAME SCALE: NONESCALE: NONE �E Fire Sprinklere, Inc. 00504N Automatic Fire 5prinklera, Inc, 00505N B 19 1 1 TOTAL PER FLOOR 17 TOTAL PER UNIT 34 TOTAL THIS SHEET DATE I SUBMITTAIS 09/13/16 1 QA REVIEW BY MPF NO. DATE REVISIONS BY /I\ x A NFPA 13Dr 2010 GENERAL NOTES SCALE: NONE 00678N IVA B B W a Birch Birch Willow 67 6 4 bmw` 164, SPRINKLERS SPACING SPRINKLERS T HORNEBROOKE TOWNHOMES OMES T -QUANTITY -1 WHITE CEDAR ROAD SYMBOL MAXIMUM MINIMUM COMMENTS SYMB IST 2ND SIN SIZE K TEMP MODEL Q 16X16 8 BETWEEN 8'-0" MAX SPACING OFF WALL U.N.O, s O 7 9 R3516 DATE, SEPTEMBER 12, 2016 4,9 155 . RELIABLE MODEL Fl ® U.N.O. SPRINKLERS DEFLECT T INSTALLED p � OR 0 BE IN TA LED 1-4 BELOW CEILING JACKSONVILLE, FL 32256-2745 PHONE (904) 268-3030 TAMPA, FL 33619-8337 PHONE. (813) 630-0303 POMPANO BEACH, FL 33064-1408 PHONE: (954) 917-3030 CONTRACT # �� �� FAX: (904) 268-0724 FAX: (813) 630-0312 WHITE W/ RECESSE ® 1 0 R3516 SET # 4,9 175 , RELIABLEMODEL F1 VWITC W/ orrrccr B 19 1 1 TOTAL PER FLOOR 17 TOTAL PER UNIT 34 TOTAL THIS SHEET DATE I SUBMITTAIS 09/13/16 1 QA REVIEW BY MPF NO. DATE REVISIONS BY /I\ x A NFPA 13Dr 2010 GENERAL NOTES SCALE: NONE 00678N IVA B B W a Birch Birch Willow 67 6 4 bmw` 164, LOTS 64-69 T HORNEBROOKE TOWNHOMES OMES WHITE CEDAR ROAD SANFORD FL 32771 WA'"E TAYLOR MORRISON HOMES Automatic Fire Sprinklers, Inc. 151 SOUTHHALL LANE, SUITE 200 MAITLAND, FL 32751 / MAIN OFFICE — ORLANDO, FLORIDA SHEET TITLE, REDWOOD UNIT FIRE SPRINKLER LAYOUT 222 CAPITOL, COURT OCOEE, FLORIDA 34761 DRAWN BY: MICKEY FERGUSON PHONE: (407) 6S6-3030 FAX: (407) 555-8026 TOTAL A/S- 1 1 0 DATE, SEPTEMBER 12, 2016 JACKSONVILLE, FL TAMPA, FL POMPANO BEACH, FL AH CITY OF SANFORD 11325 DISTRIBUTION AVE WEST 3226 CHERRY PALM DRIVE 3121 NW 16TH TERRACE JACKSONVILLE, FL 32256-2745 PHONE (904) 268-3030 TAMPA, FL 33619-8337 PHONE. (813) 630-0303 POMPANO BEACH, FL 33064-1408 PHONE: (954) 917-3030 CONTRACT # �� �� FAX: (904) 268-0724 FAX: (813) 630-0312 FAX: (954) 817-9424 CENTER OF TILE JqB? 0 YES NO CENTER DN FIXTURES J Q YES NO FT. MYERS, FL 4683 LAREDO AVE. FT. MYERS. FL 33905-4924 CONCORD, NC 4370 MOTORSPORT DRIVE CONCORD, NC 28027-8977 STATE LICENSES: NC SPRINKLER: 29745 NC ALARM; 29222 SP LV SET # CONSTRUCTION TYPE, V B PHONE (239) 433-3030 FAX: (239) 433-3263 PHONE: (704) 782-3032 FAX: (704) 795-6838 SC SPRINKLER; 1116 SC ALARM; 3386. FPRN 1 UCCUPANCYtR- t "I 1ST FLOOR 2ND FLOOR WILLOW UNIT FIRE PROTECTION PLAN �� '� � 1' $� (2,059 SQ. FT.) 1 SCALE 1/4' = 1' W_1 W-2 COMMENTS 0 ® HAZARD CLASS NFPA 13D NFPA 13D 155' I1[F'C7R :'ANT__ O WNER INF'ORMAUJOIV ElIc's ELEIvILN'TS �N<7'r FIRE SPRINKLER CUNSTRUCTIUN DRAWINGS AND SHOP DRAWINGS MAY INCLUDE WATER SUPPLY INFORMATION 1 THIS IS DRAWING IS BASED ON THE OWNER'S ACCEPTANCE OF 7HE CURRENTLY ADOPTED ''i (EITHER STATE UR LOCAL) 0F NFPA AS THE APPLICABLE STANDARD FOR i CKNDDRAWIN S GRAPHICS ➢❑ RUWED FROM THE ARCHITECTURAL rIEDIT1UN STRUCTURAL, OR MEP DRAWINGS. THESE REFERENCE BACKGROUND ELEMENTSARE FUR ,05 ,05 THE INSPECTION, TESTING AND MAINTENANCE OF WATER BASED FIRE PROTECTION GENERAL INFORMATION OR CONTEXT ONLY AND THE FIRE SPRINKLER ENGINEER DOES DESIGN AREA SF, 2 SPRKS DROUGHT OR FIRE -PUMP SYSTEMS. PER SECTION 4,1, THE RESPONSIBILITY FOR PROPERLY MAINTAINING A NOT ACCEPT ANY RESPONSIBILITY FOR THESE ELEMENTS. THE FIRE SPRINKLER 40,7 EXTRAPOLATED GPM REQ'D a DW 32,9 WATEBUILllINGASED THE OWNER. IF THE ENGINEER THE EFIRESIBLE ACTUAL (AS REQ'D BY AHJ) SIZE: GPM Q PSI OWNERRHAS NOTCTION RECEIVEDTAMCOPYLOFBTHISAPAMPHLET AND/OR IS NOT FAMILIAR WITH THE OPERATION AND MAINTENANCE OF THIS SYSTEM, PLEASE CONTACT DRAWINGSIDEPICTINGNLY SPRINkPERTHOSE SCUPES,OFIONS WORK.F REFER1RE TO APPROVLER ED ARCHITECTURAL, STRUCTURAL, MEP OR CIVIL DRAWINGS FUR AUTHORITATIVE 37,9 25,0 ELESPRINKLER R ON a HIGHEST THE NEAREST OFFICE OF WAYNE AUTOMATIC FIRE SPRINKLERS, INC. EXPRESSIUNS OF BACKGROUKD INFORMATION ORDETAILS MAYBE UTILIZED IN FIRE I STATIC PRESSURE 66 PSI SE IINNSIDUOUTSIDE HYDRANT ELEV, 2' N/A DOMESTIC DEMAND 5 GPM 5 GPM ` RESIDUAL PRESSUR 56 PSI DATE OF TEST 09/06/16 CPVC C;OMPATIBILITX NOTICE CPVC SYTEMS HAVE BEEN USEDFOR THAN ORYEARSI INLER NEW PIPING CONSTRUCTION, RE -PIPE AND REPAIR, G VCULLY PRUDUCTSMORE ARE FLOW IN GPM 1010 GPM TIME OF TEST 8:00 AM 12 IDEALLY SUITED FOR THESE APPLICATIONS DUE TO THEIR OUTSTANDING CORROSION TOTAL PER FLOOR 18 TOTAL PER UNIT 36 'i RESISTANCE, OCCASIONALLY, HOWEVER, CPVC CAN BE DAMAGED BY CONTACT WITH CHEMICALS FOUND IN SOME CUNSTRUCTIUN MATERIALS CIE, SOME WIRES, FLUX, PITOT READING 36 PSI NUMBER OF PORTS FLOWED I PETROLEUM BASED PRODUCTS, ETC,) AND ANCILLARY PRODUCTS SUCH AS THREAD SEALANTS, LEAK DETECTORS, FIRESTUPS, ETC. ANY PRODUCT THAT COMES IN CONTACT WITH CPVC SPRINKLER PIPE MUST BE EVALUATED IN ACCORDANCE WITH THE SYSTEM COMPATIBILITY PROGRAM AS FOUND AT WWW,SYSTEMCOMPATIBLE,COM e TEST PROVIDED BY WAYNE AUTOMATIC FIRE SPRINKLERS, INC. G CJ P YR I G FIIF CL ALL DOCUMENTS, I,NCLUDING ORIGINAL DRAWINGS, SPECIFICATIONS, FIELD NOTES, ESTIMATES AND DATA, INCLUDING COMPUTER PROGRAMS PURSUANT TO THIS PROJECT N ARE AND WILL REMAIN THE PROPERTY OF WAYNE AUTOMATIC FIRE SPRINKLERS, INC, N " (WAFS) AS INSTRUMENTS OF SERVICE. THEY ARE HOT INTENDED, NOR REPRESENTED TO BE SUITABLE FOR RE -USE BY THE CLIENT, OR OTHERS, ON EXTENSION OF THIS PROJECT, OR FOR ANY OTHER PROJECT. ANY REUSE, OR ADAPTATION OF THE HYDRANT N FROM WAFS rIFORMAE: CONTAINED HEREIN, RISK, SPECIFIC WRITLIABILITY, !' A W LEGAL E TO WILL BE AT THE CLIENTS SOLE RISK, WITHOUT LIABILITY, OR LEGAL EXPOSUREWAFS, LOCATION OR TEST HYDRANT LOCATED ON WHITE CEDAR ROAD � AND TITLE F O FURTHER T ILL NWAF RATES TO NIFY NUMBER (z)' AGREED ON BETWEEN S AND THE CLIENT, THE CL IENTTSHALLION ALSO INDEEM ND HOLD WAFS HARMLESS FROM ANY AND ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES, INCLUDING ATTORNEYS FEES RESULTING FROM ANY SUCH PERMISSIONS. 00 rn DESIGN CRITERIA SYSTEM / DESIGN AREA # W_1 W-2 COMMENTS 0 ® HAZARD CLASS NFPA 13D NFPA 13D 155' RELIABLE MODEL Fl RES, PEND. WHITE W/ RECESSED ESCS, # OF SPRINKLERS IN DESIGN AREA 2 1 MINIMUM DENSITY ,05 ,05 DESIGN AREA SF, 2 SPRKS 1 SPRKS PSI REQ'D e BW 39,5 40,7 GPM REQ'D a DW 32,9 20.0 PSI REQ'D e HYD 52,3 50,1 GPM REQ'D a HYD 37,9 25,0 ELESPRINKLER R ON a HIGHEST 19'_8' 31'_0' SE IINNSIDUOUTSIDE N/A N/A DOMESTIC DEMAND 5 GPM 5 GPM SPRINKLERS SPACING SYMBOL MAXIMUM MINIMUM COMMENTS 0 ® 16161 U.N.O. 8' BETWEEN SPRINKLERS 8'-0" MAX SPACING OFF WALL U.N.O. DEFLECTOR CEILING TALLED 155' RELIABLE MODEL Fl RES, PEND. WHITE W/ RECESSED ESCS, CONSTRUCTION TYPE, V -B OCCUPAN%-3 f 1 TO SPRINKLER SYSTEM TxSEE UNIT PLANS FOR CONTINUATION 6' 120VAC BELL W/WEATHERPROOF BACK BOX LOCATE ON OUTSIDE WALL OF WOOD FLOOR TRUSS BUILDING (WIRED BY OTHERS) -�: f-11&` SPLIT RING HANGER 3/8' A,T,R, & HILTI DROP-IN ANCHOR c� 7 3' X 3' X V CPVC REDUCING TEES_, Wx IX' x" CPVC REDUCING TEE W/ NO SPARE SPRINKLERS V x 1' CPVC SPIG ADAPTERREQUIRED PER NEPA 13D GALV PLUG AND 300 PSI WATER GAUGE &3 -WAY VALVE 3'xI%'xl" CPVC REDUCING TEE W/POTTER GLUE IN FLOW SWITCH (WIRED BY OTHERS) F----` CPVC BALL VALVE t It CPVC CHECK VALVE--------.- -:, ALVE—fir 1V COUP & 111411 CPVC BUSHING B V CPVC 90' OUT WALL TO VA' SPIGOT ADAPTER OVERHEAD PERMIT TO & SAWN HEAD START AT 1'-O" A.F.F. 7 DYNAFLOW SLEEVE---- FROM LEEVE)FROM SUPPLY 1 1/2' PIPE ROTATED FOR CLARITY BY OTHERS CPVC _ TYPICAL EXPOSED CPVC FIRE SPRINKLER RISER 111II�T E Fire Sprinklere, Inc. TYPICAL SPRINKLER 36' �— MINIMUM'S TYPICAL LIGHT Sf FIXTURE * DESIGN AND INSTALLATION TO BE IN ACCORDANCE WITH 2010 EDITION OF NFPA 13D, * DESIGN AND INSTALLATION TO BE IN ACCORDANCE WITH ALL APPLICABLE LOCAL AND STATE CODES. * ALL PIPE AND FITTINGS USED ON THIS PROJECT TO BE IN ACCORDANCE WITH APPLICABLE CODES AND WAFS STANDARDS, SEE PIPE AND FITTINGS GENERAL NOTES (WAFS DETAIL #00593N). t * ALL HANGERS SHALL BE DESIGNED AND INSTALLED IN ACCORDANCE WITH NFPA 13D AND THEIR LISTING. * ALL PENETRATIONS THROUGH RATED BUILDING ASSEMBLIES SHALL BE SEALED WITH FIRE CAULK IN ACCORDANCE WITH DETAILS PROVIDED. WAFS POLICY IS TO USE HILTI FS ONE OR STI LCI. * UNDERGROUND MAINS AND LEAD-INS SHALL BE FLUSHED AND SIGNED TEST CERTIFICATES PROVIDED BEFORE A CONNECTION IS MADE TO THE SPRINKLER SYSTEM. * WHEN SYSTEM IS FED USING PLUMBING SERVICE, PIPING SHALL STILL BE FLUSHED PRIOR TO CONNECTING THE SPRINKLER SYSTEM. * ALL PIPING SHALL BE INSPECTED AND APPROVED BY PROPER AUTHORITIES PRIOR TO COVERING WITH DRYWALL. COPIES OF SIGNED TEST CERTIFICATES ARE TO BE FORWARDED TO THE PROPER RECIPIENTS. * ALL SYSTEMS SHALL BE TESTED AT 200 PSI FOR 2 HOURS PER WAFS STANDARDS. # ALL SOFFITS REQUIRED TO CONCEAL SPRINKLER PIPING ARE BY OTHERS, #r ALL WIRING OF DEVICES IF PROVIDED (FLOW SWITCHES, TAMPER SWITCHES, ETC) IS BY OTHERS. * VALVES SHALL NOT BE REQUIRED TO BE MONITORED PER FLORIDA BUILDING CODE 903.4 (1). * LOCAL WATERFLOW ALARMS SHALL BE PROVIDED ON ALL SPRINKLER SYSTEMS IN HOMES NOT EQUIPPED WITH SMOKE ALARMS OR SMOKE DETECTORS IN ACCORDANCE WITH NFPA 72, NATIONAL FIRE ALARM CODE. * CONNECTION OF SPRINKLER DEVICES TO THE BUILDING ALARM OR MONITORING SYSTEM, IF PROVIDED, IS BY OTHERS. * ALL PAINTING OF PIPE AS REQUIRED IS BY OTHERS. * ALL INSULATION REQUIRED FOR FREEZE PROTECTION OF SPRINKLER PIPING IS BY OTHERS. * HEATING OF ROOMS TO MAINTAIN TEMPERATURES OF 40 DEGREES OR GREATER IS BY OTHERS,. I# SPRINKLERS SHALL NOT BE INSTALLED PRIOR TO THE FITTINGS BEING CEMENTED IN PLACE. * ALL SPRINKLERS IN DWELLING UNITS SHALL BE UL LISTED OR FM APPROVED RESIDENTIAL SPRINKLERS, #r SPARE SPRINKLERS WILL NOT BE PROVIDED AS THEY ARE NOT REQUIRED BY NFPA 130. * REFER TO SPACING NOTES ON PLANS FOR MAXIMUM CALCULATED SPACING ALLOWANCES. * SPRINKLERS SHALL BE INSTALLED IN ALL AREAS EXCEPT AS FOLLOWS: o BATHROOMS WHERE THE AREA DOES NOT EXCEED 55 SQ FT, o CLOTHES CLOSETS, LINEN CLOSETS AND PANTRIES WITHIN THE DWELLING UNITS THAT DO NOT EXCEED 24 SQUARE FEET, THE LEAST DIMENSION DOES NOT EXCEED 3 FEET, AND THE WALLS AND CEILINGS ARE SURFACED WITH NONCOMBUSTIBLE OR LIMITED -COMBUSTIBLE MATERIALS AS DEFINED BY NFPA 220, STANDARD ON TYPES OF BUILDING CONSTRUCTION. o ANY GARAGES, OPEN ATTACHED PORCHES, CARPORTS AND SIMILAR STRUCTURES, o ATTICS, PENTHOUSE EQUIPMENT ROOMS, ELEVATOR MACHINE ROOMS, CONCEALED SPACES DEDICATED EXCLUSIVELY TO AND CONTAINING ONLY DWELLING UNIT VENTILAION EQUIPMENT, FLOOR/CEILING SPACES, ELEVATOR SHAFTS, CRAWL SPACES, AND OTHER CONCEALED SPACES THAT ARE NOT USED OR INTENDED FOR LIVING PURPOSES AND DO NOT CONTAIN FUEL -FIRED EQUIPMENT. o COVERED UNHEATED PROJECTIONS OF THE BUILDING AT ENTRANCES/EXITS A5 LONG AS THERE IS ANOTHER MEANS OF EGRESS FROM THE DWELLING UNIT. o SPRINKLERS SHALL NOT BE REQUIRED FOR, CEILING POCKETS THAT MEET THE FOLLOWING CONDITIONS: 1. THE TOTAL VOLUME OF UNPROTECTED CEILING POCKET DOES NOT EXCEED 100 CU. FT. 2. THE ENTIRE FLOOR UNDER THE UNPROTECTED CEILING POCKET IS PROTECTED BY THE SPRINKLERS AT THE LOWER CEILING ELEVATION. 3. EACH UNPROTECTED CEILING POCKET IS SEPARATED FROM ANY ADJACENT UNPROTECTED CEILING POCKET BY A MINIMUM OF 10 FT, HORIZONTAL DISTANCE. 4. THE INTERIOR FINISH OF THE UNPROTECTED CEILING POCKET IS NONCOMBUSTIBLE OR LIMITED -COMBUSTIBLE MATERIAL. 5. SKYLIGHTS NOT EXCEEDING 32 SQ. FT. SHALL BE PERMITTED TO HAVE A PLASTIC COVER. * WAFS TO PROVIDE ALL REQUIRED SIGNAGE PER NFPA 130 INCLUDING BUT NOT LIMITED TO VALVES, HYDRAULIC PLACARDS, AND INSPECTION TAGS AS REQUIRED BY FS 633. * DEVICES THAT RESTRICT THE FLOW OR DECREASE THE PRESSURE OR AUTOMATICALLY SHUT OFF THE WATER TO THE SPRINKLER SYSTEM, SUCH AS WATER SOFTENERS, FILTRATION SYSTEMS, AND AUTOMATIC SHUTOFF VALVES, SHALL NOT BE ADDED TO THIS SYSTEM WITHOUT A REVIEW OF THE FIRE SPRINKLER SYSTEM BY A FIRE PROTECTION SPECIALIST. SCALE: NONE `J V r AYNE AutwoM Rn SprkidarR km *IN ROOMS/COMPARTMENTS 400 CU, FT OR LESS, L LILINLI r AN --• SPRINKLERS MAY BE PLACED REGARDLESS OF (ANY MODEL IS ACCEPTABLE LOCATION OF OBSTRUCTIONS, PROVIDED PLAN VIEW OF BLADES IS 50% OPEN) NFPA 13R & 13D NFPA 13R G 13D SPRINKLER CLEARANCE W/ LIGHT FIXTURE SPRINKLER CLEARANCE W/ CEILING, FAN AXt�E SCALE NONESCALE: NONE AYNE Fire Sprinklere, Inc. 00504N Automatic Fire Sprinklere, Inc. 00505N r-- QUANTITY --i SPRINKLERS SYMB IST 2ND SIN SIZE K TEMP MODEL O 6 12 DRAWN BY, MICKEY FERGUSON TOTAL A/& 110 R3516 AHJ CITY OF SANFORD 4.9 155' RELIABLE MODEL Fl RES, PEND. WHITE W/ RECESSED ESCS, CONSTRUCTION TYPE, V -B OCCUPAN%-3 6 12 1 TOTAL PER FLOOR 18 TOTAL PER UNIT 36 TOTAL THIS SHEET DATE SUBMITTAIS 09/13/16 1 16 QA REVIEW NO. LUTE I REVISIONS x BY MPF BY A NFPA 130 2010 GENERAL NOTES SCALE: NONE 00678N win a' a a imim 99,11m9liml A WA'"M IE Automatic Fire Sprinklers, Inc. MAIN OFFICE - ORLANDO, FLORIDA E 22 CAPITOL COURT OCOEE, FLORIDA 34761 PHONE: (407) 555®3030 FAX: (407) 85113-13020 JACKSONVLLE, FL TAWff'A, FL POMPANO BEACH, FL 11326 DISTRIBUTION AVE, WEST 3228 CHERRY PALM DRIVE 8121 NW 16TH TERRACE JACKSONVILLE, FL 32256-2745 TAMPA. FL 33618-8337 POMPANO BEACH, FL 33084-1408 PHONE: (904) 268-3030 PHONE: (013) 630-0303 PHONE; (864) 817-3030 FAX: (904) 268-0724 FAX: (813) 630-0312 FAX: (954) 917-9424 FT. MYERS, FL CONCORD, NC STATE LICENSES: 4683 LAREDO AVE. 4370 MOTORSPORT DRIVE NC SPRINKLER: 29745 FT. MYERS. FL 33905-4924 CONCORD, NC 28027-8977 NC ALARM: 29222 SP LV PHONE: (239) 433-303D PHONE: (7D4) 782-3032 SC SPRINKLER; 1116 FAX: (239) 433-3263 FAX: (704) 795-6838 SC ALARM: 3385 LOTS 64-69 i THOR NESR00 E K TOWNHOM S E WHITE CEDAR ROAD SANFORD FL 32771 � TAYLOR MORRISON HOMES 151 SOUTHHALL LANE, SUITE 200 MAITLAND, FL 32751 SHEET TITLE, WILLOW UNIT FIRE SPRINKLER LAYOUT DRAWN BY, MICKEY FERGUSON TOTAL A/& 110 BATE, SEPTEMBER 12, 2016 AHJ CITY OF SANFORD CONTRACT 1 84196 CENTER OF TILE JOB? [:] YES ND CENTER ON FIXTURES JOB? a YES UNQ SHEET It F Pw' 1 CONSTRUCTION TYPE, V -B OCCUPAN%-3