Loading...
105 McKay Blvd 17-1272; REMODEL AND HVAC71 ZotBJN1 CITY OF sANI=c RI. r BUILDINGING & FIREPREVENTION PERMIT APPLICATION A, pi cation ,No: . Documented Construction Value: T Job Address r HistoricDistrei: Yes Io Parcel IID: 31 (q 31 S Z i QjSQ(D Z, Q Residential Commercial F Type of Work: New Q Addition El Aiteration 14 Repair[] Demo E] Change of Use Emove E. Description of Work: .. r Y' 7- Plan Review Contact Person: Title: Phone: Fax: Property Owner Information Name ~ 4 t_ (} 12 1 i f J U S u P € ne: 0 - 5 } 5°_ St-P4 0 Street: I Z. 3 - .5 +7D N { Resident of property? : N 0 City, State Zip: 0, ty rs/2 c21_;y FL C6ntr'act0"r. lhf6 ' n0ionName ,Phone: C Street; Fad: City, State Zip: / r ,( _75 State License -,No.: Architect/Engineer Intortna ion Name., Phone Street: Fax: City, St, Zip: E-irtail: Bonding Company: (Mortgage - Lender: Address: Address: WARNING TO OWNER: ' SOUR FAILURE TO RECORD A 'NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR I I MPROVEMENTS TO YOURPROPERTY. A NOTICE OF COMMENCEMENT MUSTRE RE CORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. l[)F' YOU :INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR -,LEN DER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF' COMMENCEMENT. Application is hereby made to obtain a permitto do the work and installations as indicated. I certify that no Work or installation has commenced prior to the issuance of a permit and that all work wiIH be performed to'rneet standards of all laws regulating congruction in this jurisdiction- I understand that a separate permit trust be secured for electrical work, plumbing, signs, wells, Pools, furnaces, boilers, heaters, tanks, and air conditioners, etc, _ FBC 105.3 Shall be inscribed With the date of application and the code in effect as of that date: 51" Edition (2014 da Building Code . Revised: June30, 2015 Permit Application O NOTICE': In addition to the requirements of this permit; there may be additional restrictions applicable to this property that maybe found in the public records of this county, and there .may be additional permits required from other governmental entities such as water management districts, state agencies, or federal ,agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated cOnstruction.value of'the job at the time of submittal. The actual construction value will be figured based or, the current ICC Valuation Table in effect at the time the permit is issued, in accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value, credit will be applied to your permit fees when the permit is issued. OWNER'S AFFIDAVIT: J certify that all of the foregoing information is accurate and that all work will be doate in compliance with all applicable laws regulating construction and zoning. Sig cureo£OwnerlAgent Date $ aturc Contrac-tmlA rratc Print OwncrfAgcni s Name i[ii Cditi' C t:71t'S, Qte: 301--,) an re of Notary=State rfg TEPHAWE SALAS Nni- Saiy Public, M I FlorU9a OcmmisSiottA GG 25748 M d rtm. axPlt03 A00,29, 2020 Owner/ Agertt is Peronally t „v , or vntractnrlAgentnj , . ersona ly Known to lY1e of Produced ID 7 ? e of ID 1' { T Z Lc L . Produced ID _ type of"ID ELL W IS FOR OFFICE USE, ONLY Permits : Required: Building Electrical Q Mechanical K Plumbingn Gas,[] Roof F Construction Type: Occupancy Use: Flood Zone: Total Sq la t of Bldg: _ 1!'.lixv Occupancy I,aad: # of;Stories% New Construction: Electric - # of Amps Plumbing - # of Fixtures Fire Sprinkler ,Permit: Yes' No 0 t# of :Heads Eire Alarm Permit: Yes Q Non APPROVALS: ZONING: UTILITIES: COMMENTS: Revised: tune 30, 20t5 WASTEWATER: ENGINEERING: FIFE: BUILDING- GE 4 RECORD COPY FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Durbin Builder Name: Air Design He=tin & F;C . gvILD//Uv Street: 105 McKay Blvd. Permit Office: i{TJ 7 L City, State, Zip: Sanford ; FL , 32771 Permit Number: SAPNFORD Owner: Jurisdiction: Design Location: FL, Sanford County:: Seminole (Florida Climate Zone 2) A RT4=t+ 1. New construction or existing Existing (Projecte 1. Wall Types (1280.0 sgft.) Insulation Area. 2. Single family or multiple family Single-family a. Concrete Block - Ext insul, Exterior R=5.0 1280.00 ft2 b. N/A R= ft2 3. Number of units, it multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 10. Ceiling Types (1330.0 sgft.) Insulation Area 5. Is this a worst case? No a. Under Attic (Vented) R=30.0 1330.00 ft2 6. Conditioned floor area above.grade (ft2) 1374 b. N/A R= ft2 Conditioned floor.area below grade (ftz) 0 c. N/A 11. Ducts R= ft2 R ft2 7. Windows(208.0 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Main 6 425 a. U'-Factor: Dbl, U=0.30 208.92 ft2 SHGC: SHGC=0.20 b. U-Factor: N/A ft2 12. Cooling systems kStu/hr Efficiency" SHGC: a. Central Unit 35.2 'SEER:1.4.00 c. U=Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Heal Pump 35.2 HSPF:9.00 SHGC: Area Weighted Average Overhang Depth: 2.000 It: Area Weighted Average SHGC: 0.200 14. Hot water systems a. Electric Cap: 50 gallons S. Floor Types '(1374.1 sgft) Insulation Area EF: 0.950 a. Slab -On -Grade Edge Insulation R=0.0 1374.10 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 15. Credits Pstat Total Proposed Modified Loads: 42.15 Glass/Floor Area: 0.152 PASS Total Baseline Loads: 45.58 a I hereby certify that the plans. and specifications covered by Review of the plans and 04t VHh ST4r` this calculation are in compliance with the Florida Energy specifications covered by this Qy Code. f calculation Indicates compliance with the Florida Energy Code. 1. rq,r{ PREPARED BY. - ____( _ Before construction is completed this building will be inspected for E0 '1tliDATE: compliance with Section;553.908 a_ I hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Energy Code. OWNER/AGENT:---- _____. _ .---___.. _.__,. _.__._-_._.-___._: BUILDING OFFICIA: DATE: -------_..-.._._... -- DATE: - --_ 1' 6 1---------- Compliance requires certification by the air handier unit manufacturer that the air handier enclosure qualifies as certified factory -sealed in accordance with R403.2.2.1. Compliance. requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. 9/3/2017 2:42 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software ,Page 1 of 4 r vi IIYr r PROJECT Title: Durbin Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 1374 Lot # Owner: Total Stories: 1 Block/SubDivision: of Units: 1 Worst Case: No PlatBook: Builder Name: Air Design Heating A/C Inc. Rotate Angle: 0 Street: 105 McKay Blvd, Permit Office: Cross Ventilation: No County: Seminole Jurisdiction: Whole House Fan: No City, State, Zip: Sanford . Family Type: Single-family FL. 32771 New/Existing: Existing (Projected) Comment: CLIMATE IECC Design Temp Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture RangeDesignLocationTMYSiteZone97.5 % 2.5 % FL Sanford FL-ORLANDO_SANFOR 2 39 93 70 75 677 44 Medium BLOCKS Number Name Area Volume Biockl 1374 10992 SPACES Number Name - Area Volume, Kitchen T Occupants Bedrooms- "-Infil 1D- Finished Cooled T Heated 1 Main 1374 1.0992 Yes 4 3 l: Yes Yes Yes FLOORS 77 # FloorT a Space Perimeter . R-Value Area ^ Tile Wood Carpet I Slab -On -Grade Edge Insulatio Main 160 ft 0 0 1`12 ____ 0 0 1 ROOF J Roof Gable Roof Solar SA Emitt Emitt Deck Pitch Tested Tested Insul. (deg) Type Materials Area Area Color Absor. 1 Hip Composition shingles 1448 ft2 0 ft2 Light 0.75 N 0.9 No 0 18.4 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 1374 ft2 N N CEILING Type Space R-Value Ins Type Area — Framing Frac _ Truss Type _ 1 Ceiling Under Attic (Vented) Main 30 Blown 1330 ft2 0.1 Wood 9/3/2017 2:42 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 4 FORM R405-2014 WALLS:-- Adjacent Cavity Width Height Sheathing Framing Solar Below Ornt-._, To ------Wall T-ype--._____-.____ Space Area. _..._.... R-Value-Fraction---Absor-GradeP/o- 1 N Exterior Concrete Block - Ext Insul Main 5 51 0 8 0 408:0 W 0 0 0.8 0 2 E Exterior Concrete Block - Ext Insul Main 5 29 0 8 0 232:0 ft2 0 0 0.8 0 3 S Exterior Concrete Block - Ext Insul Main 5 51 0 8 0 408.0 ft2 0 0 0.8 0 4 W Exterior Concrete Block - Ext Insul Main 5 29 0 8 0 232.0 ft2 0 0 0.8 0 DOORS Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 S Insulated Main None 29 3 7 21 ft2 WINDOWS 0fie ntation shown is the entered, Pro 'osed orientation. Wall Overhang v # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int.Shade Screening 1 n 1 Vinyl Double (Clear) Yes; 0.3 0.12 9.0 ft2 2 It 0 in 2 ft 0 in None Exterior 5 2 n 1 Vinyl Double (Clear) Yes 0.3 0:2 7.9 ft2 2 ft 0 in 2 ft 0 in None Exterior 5 3 n 1 Vinyl Double (Clear) Yes 0.3 0.2 15.0 ft2 2 ft 0 in 2 ft 0 in None Exterior 5 4 n 1 Vinyl Double (Clear) Yes 0.3 0.2 42.0 ft2 2 ft 0 in 2 ft 0 in None Exterior 5 5 e 2 Vinyl Double (Clear) Yes 0.3 0.2 15.0 ft2 2 It 0 in 2 ft.0 in None Exterior 5 6 s 3 Vinyl Double Clear) Yes 0.3 0.2 90.0 ft2 2 ft 0 in 2 ft 0 in None Exterior 7 W 4 Vinyl Double (Clear) Yes 0.3 0.2 30.0 ft2 2 It 0 in 2 ft 0 in Norie Exterior 5 INFILTRATION Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000254 916 50.29 ^ 94.57 1855 5 HEATING SYSTEM System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump Split HSPF:9 35.2 kBtu/hr 1 sys#1 COOLING SYSTEM System Type _ Subtype Efficiency -Capacity Air Flow SHR Block Ducts 1 Central Unit Split SEER: 14 35.2 kBtu/hr cfm 0.7 1 sys#1 HOT WATER SYSTEM System Type SubType Location - EF Cap Use SetPnt J Conservation 1 Electric None Main 0.95 50 gal 60.9 gal 120 deg None M 9/ 3/2017 2:42 PM EdergyGauge(D USA - FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 4 FORM R405-2014 NERDY PERFORMANCE LEVEL (EP,L) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX*= 92 The lower the EnergyPerformance Index, the more efficient the home. 105 McKay Blvd., Sanford, FL, 32771 1. New construction or existing Existing (Projecle 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=5.0 1280.00 ft2 b. N/A R= ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 10. Ceiling Types Insulation Area 5. Is this a worst case? No a. Under Attic (Vented) R=30.0 1330:00 ftz 6. Conditioned floor area (ftz) 1374 b. N/A R= ft2 7. Windows— Description Area c. N/A R= ft2 R ft2 a. U-Factor: Dbl, U=0.30 208.92 ft2 11. Ducts a. Sup: Attic, Ret: Attic, AH: ,Main 6 425 SHGC: SHGC=0:20 b. U-Factor:. N/A ft2 SHGC: 12. Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ft2 a. Central Unit 35.2 SEER:14.00 SHGC: d. U-Factor: N/A ft2 13. Heating systems kBtu/fir Efficiency SHGC: ra. Electric Heat Pump 35.2 HSPF:9.00 Area Weighted Average overhang Depth: 2.000 ft. Area Weighted Average SHGC: 0.200 8. Floor Types Insulation Area 14. Hot water systems Cap: 50 gallons a. Slab -On -Grade Edge Insulation R=0.0 1374.10 ft2 a. Electric EF: 0.95 b. N/A R= ft2 i. Conservation features c. N/A R= ft2 None 15: Credits Pstat 1 certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: Address of New Home: Date: City/FL Zip: Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 9/3/2017 2:43 PM EnergyGauge® USA - FlaRes2014 - Section R405.4.1 Compliant Software ESE Page 1 of 1 Project Summa Job: Air Design Heating & A/C Inc. By: P08ox 729„ Ocala. FI 34418 Phone: 352.629.2626 Fax 352.368.V88 Email: salesQairdesignac.com Web: www:airdesignae.com License: cAc1814997 For'. Notes: Weather: Ocala Muni (AWOS), FL, US Winter Design Conditions Summer Design Conditions Outside db 34 °F Outside db 92 °F Inside db 70 °F Inside db 75 °F Design TD 36 °F Design TD 17 °F Daily range M Relative humidity 50 % Moisture difference 41 gr/lb Heating Summary Structure 20866 Btuh Ducts 5810 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Piping 0 Btuh Equipment load 26675 Btuh Infiltration Method Construction quality Fireplaces Simplified Average 0 Neatip Coolin Area (ft 1374 Volume (113) 10993 10093 Air changes/hour 0.45 0.23 Equiv. AVF (cfm) 82 42 Heating Equipment Summary Make Rheem Trade RHEEM; RUUD Model RP1436AJ1 AHRI ref 7489178 Efficiency 9 HSPF Heating input Heating output 34800 Btu h @ 47-'F Temperature rise 27 °F Actual air flow 1173 cfm Air flow factor 0.044 cfm/Btuh Static pressure 0.55 in H2O Space thermostat Backup: Input = 7 kW, Output = 25190 Btuh, 100 AFUE Sensible Cooling Equipment Load Sizing Structure 18948 Btuh Ducts 7272 Btuh Central vent (0 cfm) 0 Btuh Blower 0 Btu,h Use manufacturer's data n Rate/swing multiplier 0.96 Equipment sensible load 25302 Btuh Latent Cooling Equipment Load Sizing Structure 4778 Btuh Ducts 1313 Btuh Central vent (0 cfm) 0 Btuh Equipment latent load 6151 Btuh Equipment total load 31453 Btuh Req. total capacity at 0.70 SHR 3.0 ton Cooling Equipment Summary Make Rheem Trade RHEEM; RUUD Cond RP1436AJ1 Coil RH1T3617STAN AHRI ref 7489178 Efficiency 11.5 EER, 14 SEER Sensible cooling 24640 Btuh Latent cooling 10560 Btuh Total cooling 35200 Btuh Actual air flow 1173 cfm Air flow factor 0.045 cfm/Btuh Static pressure 0.55 in H2O Load sensible heat ratio 0.81 Capacity balance point = 27 ° F Calculations approved by ACCA to meet all requirements of Manual J 8th Ed 2017-Sep-0510:14:21 wrigt t t3ft' Right -Suite© Universal 2017 17.0.04 RSU06384 ge1Pa W:1PlanstLoad Calcs\Advantage - DurbinOurbin.rup Cale = MJB Front Door faces: N Job: Entire House Air Design Meeting & A/C Inc. ey: PO Box 729. Ocala. F134478 Phone: 352.629.2626 Fax: 352.368.67W Email: sales@airdesignae.com Web: www.airdesignac.com License: CAC1814997 y mix n n 9 YJ ' "'v" .- i. W r ' 1 1. , . , R " r t r wf k, For: External static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual air flow Total effective length (TEL) Heating 0.55 in H2O 0.31 in H2O 0.24 in H2O 0.188 / 0.052 in H2O 0.097 in/100ft 1173 cfm 248 Cooling 0.55 in H2O 0.31 in H2O 0.24 in H2O 0.188 / 0.052 in H2O 0.097 in/100ft 1173 cfm fAN£ : e © o ' RiV Name Design Btuh) Htg cfm) cig cfm) Design Fk Diam in) H x W in) Duct Matl Actual Ln (ft) Ftg.Egv Ln (ft) Trunk Bath c 1156 42 52 0.098 4.0 Ox 0 VIFx 40.8 150.0 st4 Bedroom 2 h 3830 168 145 0.098 7:0 Ox 0 VIFx 42.4 150.0 st4 Bedroom.3 h 4264 188 152 0.097 8.0 Ox 0 VIFx 44.3 150.0 st4 Dining c 2794 109 125 0.114 6.0 Ox 0 VIFx 34.8 130.0 st3 Family Room -A c 4176 123 187 0.113 8.0 Ox 0 VIFx 36.6 130.0 st3 Kitchen C 3276 102 147 0.144 7.0 Ox 0 VIFx 20.4 110.0 st2 Laundry h 2161 95 58 0.186 5.0 Ox 0 VIFx 11.0 90.0 stl Master h 4397 193 148 0.189 8.0 Ox 0 VIFx 9.4 90.0 st1 Master Bath c 1169 5 52 0.140 4.0 Ox 0 VIFx 23.9 110.0 st2 Office h 2910 128 100 0.137 6.0 Ox 0 VIFx 26.8 110.0 st2 wic h 465 20 7 0.189 4.0 Ox 0 VIFx 9.2 90.0 st1 Q upply Truink Deta Table wl. Trunk Htg Clg Design Veloc Diam H x W Duct Name Type cfm) cfm) FIR fpm) in) in) Material Trunk st2 Peak AVF . 864 960 0.097 688 16.0 0 x 0 VinlFlx SO st3 Peak AVF 630 661 0.097 618 14.0 0 x 0 VinlFlx st2 st4 Peak AVF 398 349 0.097 506 12.0 0 x 0 VinIFIx st3 st1 Peak AVF 1173 1173 0.097 664 18.0 0 x 0 Vin]Flx Bold7italic values have been manually overridden 2017-Sep-05 10:14:11 f' Wright.so t' Right -Suite® Universal 2017 17.0.04 RSU06384 Paget' W:\Plans\Load CalcsWdvantage - DurbinlDurbin.rup Calc = MJ8 Front Door faces: N AQ - Grill Htg c1g, TEL Design Veloc Diarn H x W Stud/Joist Duct MatlNameSize (in) cfm) Cfm) ft) FIR fpm) in) in) Opening (in) Trunk rbIl 30x 16 955 966 53.9 0.097 692 16.0 Ox 0 VI x rb2 12x 12 218 207, 34.7 0.150 626 8.0 fix 0 VlFx Boteflitalic values have beat? manually overridden A_+ wrightSOft' N17-Sep-OS 10:1a4geRight-Suited..Page 2 W:\Plans\Load CalcsWdvantage - DurbinOurbin.rup Calc = MJ8 Front Door faces; N Bath 8x4 Bedroom 2 52 cfm 12x8 168 cfm 7 „ 12" 12x12_ _ C2 C3 8 j11 C 12x8 188 cfm Bedroom 3 4" C I KM 8x8 125 cfm a 14 x 14 1211 30x16 966 cfm 12 ic 12 8 I Family om 10x10 1 ' 187 cfm 12x1I) 9n m 10x10 Laundry 147 cfm 18 Kitc en 5 '` 7 of 1611 14" Mast Bath IN 52 cfm 8x4 12x12 C5 Office 128 cfm 4 L 16 87 20 cfm I 193 cfm 218 cfm 12x8 12x12 Master Job #: Air Design Heating & A/C Inc. Scale: 1 : 51 Performed for: Page 1 PO Box 729 Right -Suite® Universal2017 Ocala, FI 34478 A 17.0.04 RSUG6384 Phone:352.629.2626 Fax:352.368.6788 2017-Sep-0510:1628 www.airdesignae.com sales@airdesignac.com csuldvantage - Durbin\Durbin.rup