Loading...
2730 River Landing Dr 17-2536 (screen room)ECEIE CITY OF SANFORD BUILDING & FIRE PREVENTION A 8 2017 PERMIT APPLICATION BY: Application No: 7 S 2(o Documented Construction Value: $ 2200.00 Job Address: 2730 River Landing Drive Historic District: Yes No Parcel ID: 26-19-30-5SY-0000-1530 Residential ® Commercial Type of Work: New Addition Alteration Repair Demo Change of Use Move Description of Work: screen room with 3" Elite panel roof on existing slab Plan Review Contact Person: Donald G. Geissler, Jr Phone: 407 461-9929 Name Frank & Tracey Martinko Street: 2730 River Landing Drive Title: President Fax: 407 365-3194 Email: sunstatesiding@aol.com Property Owner Information City, State Zip: Sanford, FL 32771 Phone: 407 754-4973 Resident of property? : yes Contractor Information Name Donald G. Geissler, Jr Sun State Siding, Inc Phone: 407 830-7778 Street: 510 Lake Lenelle Drive Fax: 407 365-3194 City, State Zip: Chuluota, FL 32766 State License No.: SCC048423 Architect/ Engineer Information Name: Craig Gunderson Florida Engineering LLC Phone: 941 391-5980 Street: 4456 Tamiami Trail, B14 Fax: 941 979-8195 City, St, Zip: Port Charlotte, FL 33980 E-mail: contact@flengineeringllc.com Bonding Company: Address: Mortgage Lender: Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. 4 FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: 5' Edition (2014) Florida Building Code Revised: June 30, 2015 Permit Application 777"' NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713, The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal. The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value, credit will be applied to your permit fees when the permit is issued. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. C : M., < .0 -7 a t r--7 Signatureoo ' — e_r/Agen at P7inOwn'er/ice shame 46, - 71///l Signature of Notary -State of Florida Date ANOREA SANDERS My COMMISSION 0 FF921054 EXPIRES NovQmber 08. 2019 Ik/)3se-0+53 Fw.M.nu ays«Nes.:on Owner/Agent is V Personally Known o e or Produced fD Type of ID Signature of Contractor/Agent Date Print Contractor/Agent's Name 7 Notary Public State of Florida Lori A Forrest My Commission FF 993138 or w Expires 07/09/2020 Contractor/Agent is Personally Known to Me or Produced ID Type of ID BELOW IS FOR OFFICE USE ONLY Permits Required: Building Electrical Mechanical Plumbing Gas Roof Construction Type: Total Sq Ft of Bldg: Occupancy Use: Min. Occupancy Load: New Construction: Electric - # of Amps. Fire Sprinkler Permit: Yes No # of Heads APPROVALS: ZONING: 2.. - UTILITIES: ENGINEERING: COMMENTS: f19. Flood Zone: of Stories: Plumbing - # of Fixtures Fire Alarm Permit: Yes No WASTE WATER: BUILDING: 'OF Ok to install screen room with 3" elite panel roof on existing slab as shown on plan. The screenenclosureshallbeconstructedwithsamedesign, material and -style as the others in the nearby and adjacent building. Revised: June 30, 2015 Permit Application SCPA Parcel View: 26-19-30-5SY-0000-1530 http://parceldetail.scpafl.org/ParcelDetaillnfo.aspx?PID=2619305 SYO... 1utn m, CFA 1 s oau Jr, a.oa plpla% Parcel Information Property Record Card Parcel: 26-19-30-5SY-0000-1530 Owner: MARTINKO FRANK W & TRACEY L Property Address: 2730 RIVER LANDING DR SANFORD, FL 32771 Parcel 26-19-30-5SY-0000-1530 Owner MARTINKO FRANK W & TRACEY L Property Address 2730 RIVER LANDING DR SANFORD, FL 32771 Mailing 2730 RIVER LANDING DR SANFORD, FL 32771 Subdivision Name RIVERVIEW TOWNHOMES PHASE II Tax District S1-SANFORD DOR Use Code 0103-TOWNHOME Exemptions 00-HOMESTEAD(2016) Value Summary Valuation Method Number of Buildings Depreciated Bldg Value Depreciated EXFT Value Land Value (Market) Land Value Ag T — Just/Market Value ** Portability Adj Save Our Homes Adj Amendment 1 Adj P&G Adj Assessed Value Tax Amount wi 2016 Tax Ta Save Our Hom, Does NOT INCLUDE Nor j Legal Description LOT 153 RIVERVIEW TOWNHOMES PHASE II PB75PGS51-58 Taxes Taxing Authority Assessment Value Exempt Values County General Fund 148,054 i --- - --- -- _.------_-- - Schools 148,054 j iCitySanford 148,054- SJWM(Saint Johns Water Management) 148,054 County Bonds 148,054 j Sales 1 of 2 5/30/17, 11:40 AM L. SUN STATE SIDING, INC. 510 LAKE LENELLE DRIVE CHULUOTA, FL 32766 407 830-7778 phone 407 365-3194 fax Submitted to: Tracey Martinko 2730 River Landing Drive Sanford, FL 32771 407 764-4973 ticmartinko(agmail.com State License SCC048423 PROPOSAL# 1 DATE 2/02/2017 Job Location: SAME Riverview Lot 153 We propose to furnish all the materials and perform all the labor necessary for the completion of: Furnish and install screen room on existing slab with 3" Elite panel roof $ 2,200.00 with 12" overhang, extruded drip edge fascia, 14' of 6" gutter and (1) 3 x 4 downspout, 1) 3' 0" x 6' 8" screen door, 18 x 14 charcoal screen, finish caulk. Chair rail height is 36" Site specific, engineer stamped plans & City of Sanford permit $ 300.00 All material is guaranteed to be as specified and the above work to be performed in accordance with the drawings and specifications submitted for the above work and completed in a substantial workmanlike manner for the sum of: $ 2,500.00 With payments to be made as follows: FULL PAYMENT UPON COMPLETION (we accept CASH or CHECK only) Any alteration or deviation from the above specifications involving extra cost will be executed only upon written orders and will become an extra charge over and above the estimate. All agreements contingent upon strikes, accidents or delays beyond our control. Owner to carry fire, tornado, and other necessary insurance upon the above work. Workman's Compensation and Public Liability insurance on above work to be taken out by Sun State Siding, Inc. THERE WILL BE A $50.00 BOOKKEEPING CHARGE IF THE INVOICE IS NOT PAID IN 30 DAYS. Submitted by DONALD G. GEISSLER, JR., PRESIDENT This proposal may be withdrawn by us if not accepted within 90 days. ACCEPTANCE OF PROPOSAL The above prices, specifications and conditions are satisfactory and are hereby accepted. You are authorized to perform the work specified. Payment will be made as outlined above. U J Printed Name -(`G C i - 4"t c- CONTRACTOR: SUN STATE SIDING DESIGN CRITERIA: RECORD COPY APPLICABLE CODES, REGULATIONS & STANDARDS: IT HE 2014 FLORIDA BUILDING CODE, 5TH EDITION SPECIFICALLY CHAPTER 16 STRUCTURAL DESIGN, CHAPTER 20 ALUMINUM & CHAPTER 23, WOOD AND AA ASM 35 and AA ADM 1 2. ASCE 7-10. WIND LOADS 1. BUILDING OCCUPANCY CATEGORY, PARAGRAPH 1604.5 & TABLE 1604.5: RISK CATEGORY 1. 2. BASIC WIND SPEED, TABLE 1609C, STATE OF FLORIDA DEBRIS REGION & BASIC WIND SPEED, PARAGRAPH 1609.3.1 & TABLE 1609.3.1 EQUIVALENT BASIC WIND SPEED: 130 MPH EXPOSURE CATEGORY, PARAGRAPH 1609.4.3: C 3. SCREENED ROOF ENCLOSURE TABLE 2002.4 FOUNDATION DESIGN FOOTING SIZE EXISTING CONCRETE SLAB. NO ADDITIONAL FOOTING OR FOUNDATION SYSTEM IS REQUIRED BY THE PROPOSED CONSTRUCTION IF A MINIMUM 4" CONCRETE SLAB IS PROVIDED IN SOUND CONDITION, FREE FROM STRUCTURAL CRACKING, SPALLING OTHER DETERIORATION. SPECIFICATIONS THE FOLLOWING SPECIFICATIONS ARE APPLICABLE TO THIS PROJECT: 1. WHERE CONCRETE SPECIFICATIONS ARE REQUIRED, WHETHER IN THE SCREEN ENCLOSURE SCOPEOF NOT, BY ONE OR MORE REGULATORY AGENCY, THE FOLLOWING SPECIFICATIONS ARE APPLICABLE: a. CONCRETE SHALL CONFORM TO ASTM C94 FOR THE FOLLOWING COMPONENTS: i. PORTLAND CEMENT TYPE 1 - ASTM C 150 ii AGGREGATES - LARGE AGGREGATE 3/4 MAX. - ASTM C 33 iii. AIR ENTRAINING+/- 1%-ASTM C 260 iv. WATER REDUCING AGENT - ASTM C 494 V. CLEAN PORTABLE WATER vi. OTHER ADMIXTURES NOT PERMITTED b. METAL ACCESSORIES SHALL CONFORM TO: i. REINFORCING BARS - ASTM A615, GRADE 60 ii. WELDED WIRE FABRIC - ASTM A185 c. CONCRETE SLUMP AT DISCHARGE CHUTE NOT LESS THAN 3" OR MORE THAN 5. WATER ADDED AFTER BATCHING IS NOT PERMITTED. d. PREPARE & PLACE CONCRETE PER AMERICAN CONCRETE INSTITUTE MANUAL OF STANDARD PRACTICE, PART 1, 2, & 3 INCLUDING HOT WHEATHER RECOMMENDATIONS. e. MOIST CURE OR POLYETHYLENE CURING PERMITTED. f. PRIOR TO PLACING CONCRETE, TREAT THE ENTIRE SUBSURFACE ARE FOR TERMITES 1N COMPLIANCE WITH THE FBC. g. CONCRETE SHALL BE PLACED OVER A POLYETHYLENE VAPOR BARRIER. 2. ALUMINUM EXTRUSIONS SHALL BE 6005T5 ALLOY. 3. FASTENERS ARE REQUIRED TO BE SAE GRADE 2 OR BETTER ZINC PLATED. 4. IT IS THE OWNERS RESPONSIBILITY TO MAINTAIN THE SCREENS, FASTENERS AND SCREENS TO MANUFACTURING SPECIFICATIONS. 5. ALL SELF MATING.BEAM SECTIONS ARE TO BE STITCHED WITH 12 SCREWS 6" FROM ENDS & 24" CENTER TO CENTER 6. THE MINIMUM NORMAL THICKNESS OF PROTECTOR PANELS KICKPLATES) SHALL BE AN INDUSTRY STANDARD OF 0.024 INCHES. 7. SCREENED ENCLOSURES CONTAINING SWIMMING POOLS SHALL COMPLY WITH THE APPLICABLE REQUIREMENTS OF FBC R4101.17 RESIDENTIAL SWIMMING BARRIER REQUIREMENTS. 8. SCREEN MATERIAL SHALL BE 18/14 SCREEN UNLESS APPROVED BY FLORIDA ENGINEERING LLC. 9..DOOR LOCATION SHALL BE DETERMINED BY CONTRACTOR IN THE FIELD. 10. ROOF BRACING SHALL BE A MINIMUM 2°x2"x.050". 11. WHEN PAVERS ARE UNDER ALUMINUM MEMBERS, CONTRACTOR SHALL EPDXY TO DECK OR GROUT TO DECK w/3000 PSI GROUT WITH BONDING AGENT 12. WHEN APPLICABLE FOR NEW FOOTER TO EXISTING, DRILL & EPDXY NEW STEEL INTO EX. FOUNDATION WITH 1" MIN. HOLE, EMBED 4" MIN W/ NON -SHRINKING SIMPSON EPDXY -TIE OR EQUAL) TYP. ALL LOCATIONS 9'-4" m 8'-6" Fn Z 1 X2 N O N N N N N Q 0 1X2 X fllj x 1 x2 u, n N 2x3 m 0 1 x2 ' x m 2x2 Z REVIEWED FOR CODE COMPLIANCE PLANS EXAMINER s- n' 11 DATE 13. INTEGRITY OF STRUCTURE SHALL NOT BE SANFORD BUILDING DIVISIONCOMPROMISEDw/ THE ATTACHMENT OF THE PROPOSED STRUCTURE A PERMIT ISSUED SHALL BE CONSTRUED TO BE A LICENSE TO PROCEED WITH THE WORK AND NOT AS SCALE: NTS AUTHORITY TO VIOLATE, CANCEL, ALTER OR SET ASIDE ANY OF THE PROVISIONS OF THE TECHNICAL CODES, NOR SHALL ISSUANCE OF A PERMIT PREVENT THE BUILDING OFFICIAL FROM THEREAFTER REQUIRING A CORRECTION OF ERRORS IN PLANS, CONSTRUCTION OR VIOLATIONS OF THIS CODE v1t-DING SANFORD 0 Al 1 7 - 2 5 3 6 Q o Z co o O p; w C)w Q= a r O Z O W a 0 el cl LL. O O cr Z CD U W N ZxL N N AN Zx L cJ EXISTING 12 O/H 3"x.024"x1 LB Zx I I N N N 4"-1` SLOPE (MIN.) 0 N N x 12 O/H TYP. 6" SUPER GUTTER Zxz i 14'-0" 3" ELITE PANEL EXISTING ROOF XTRA TRIM 2x3 24 X X X N N N o0 00 2x2 2x2 F-1 x2 1x2 O 6-2" 6'-2" ' N 12'-4" U o J r m rn Nc M fn co co r Z z Q C) D oo Q U LLLI J O Lo Z Ljw M Z 2 O r— W Q i 0 Q U O D F- O',O u_ a Z_ 0 cn N r w w w w ~ o =H C) U) 1 z SHT. OU Z_ cl Z J —I ILL. w owoY > o Z— F O w Z GNU) a ALUMINUM MEMBERS DIMENSIONS HOLLOW SECTIONS 2 X 2: 2"X2"X0.044" 2 X 3: 2"X3"X0.050" 2 X 4: 2"X4"X0.050" 2 X 5: 2"X5"X0.050". OPEN BACK SECTIONS 1 X 2: 1 "X2"X0.044" 1 X3: 1"X3"X0.045" SNAP SECTIONS 2 X 2 SNAP 2"X2"X0.045" 2 X 3 SNAP: 2"X3"X0.050" 2 X 4 SNAP: 2"X4"X0.045" SELF MATING (SMB) 2 X 4 SMB: 2"X4"X0:044"X0.100" 2 X 5 SMB: 2"X5"X0050"X0.100" 2 X 6 SMB: 2"X6"X0.050"X0.120" 2 X 7 SMB: 2"X7X0.057X0.120" 2 X 8 SMB: 2"X8"X0.072"X0.124". 2 X 9 SMB: 2"X9"X0.072"X0.124" 2 X 10 SMB: 2"X10"X0.092"X0.398" CHANNELS 1. 5"x2.125"x 1.5"x.045 2" x3.125"x2"x.045 DETAIL A ALUMINUM INTERNAL OR EXTERNAL RECEIVING CHANNEL w/(4) #10x.75" INTO GIRT OR PURLIN & (2) #14x.75" 4) # 10 x 1-1/2" SMS INTO INTO BEAM OR UPRIGHT 0.062 ANGLE SCREW BOSSES CLIPS MAYBE USED PURLIN, GIRT, HEADER OR SILL UPRIGHT, BEAM -SNAP, I. SELF MATING, OR HOLLOW DETAIL " C GIRT OR PURLIN TO BEAM OR POST DETAIL SCALE: NTS HOST ROOF PER PLAN m CO. PER PL," J J3 _ CHAIR RAIL PER PLAN cn O x x 1/4"X2-1/4" TAPCONS @ 24" 0. C. 2" X2" PER PLAN ATTACH TO ROOF PANELS W/# 12 X 2-1/2" SMS 12" O/C ALTERNATES FOR C TO 2"X2"AT HEADER: 1- DETAIL C 2 ( 4) # 10 X 3" SMS THROUGH MEMBER, INTO COL SCREW_B( 3 NOTCH COL TO RE BEAM FASTEN W/ 2) YV THRU-BOLT l" X 2" FASTEN TO ADJOINING WALL W 12 X 1-1/2" SMS 18" O/C -- EXISTING CONCRETE TYPICAL SIDE WALL DETAIL: SCREEN ROOM END WALL SCALE: NTS 1/ 8"x2"x2"x ANGLE -SELF- MATING OR SNAP SECTION TYP. 5032 H-32 ANGLE 2 -# 12 SMS INTO COLUMN Vx2" O.B. BASE PLATE-TYP. \ 1/ 4" MASONRY ANCHOR EACH o o ANGLE - EACH SIDE COL o o - 2-%" MIN. CONC.' ANCHOR. EMBEDMENT I MIN 4"SLAB 3000 PSI 2" MIN. INCREASE DISTANCE CONC. w/FIBERMESH WHEN GREATER THAN 2x4 UPRIGHT IS USED, CONC. FOOTING BELOW SIDE VIEW NOTE: WHERE PAVERS ARE PRESENT USE 5/16" TAPCON XL (RED HEAD MFG.) MASONRY ANCHORS TO PENETRATE UNDERLYING CONCRETE FOOTING 2-1/4" (MIN.) 1/ 4" MASONRY ANCHOR AT EACH ANGLE 2 - #12 SMS 1/ 4' TAPCON XL (RED HEAD MFG. OR EQUAL) 2 @ lx2 BASE 2 @'SLAB (BEYOND) 1 k2" BASE PLATE ANCHORED TO CONC w/ 1/4" MASONRY X Tg i ANCHOR 6" MAX EACH SIDE OF POS'AND 24" O.C. MAX t. CONC. FOOTING BELOW FRONT VIEW - NOTE: FOR 2Sc3 UPRIGHT TO DECK USE DETAIL " B" - 2"X4" OR LARGER SELF MATING (1) 1/4" MASONRY ANCHOR @ BASE PLATE E/S UPRIGHT TO DECK DETAILS SCALE: NTS NING BEARING WALL o 0; Lu W 0 V> > Z c b • V 0111111100 uj o U FORALUMINUMPANS - 12 X 2" SMS THROUGH BOXED END": INTO WD FASCIA - 3) PER PAN FOR PANS 12 X 9/16" SMS W/ FOR COMPOSITE PANELS SMS 5/ 8" NEO-WASHER-(3) PER PAN 12" /C 12" O/C FOR COMPOSITE PANELS 12 x PANEL THICKNESS SMS PLUS 1" LG.) W/ 1- ld' NEO- WASHER @ 12" O/C 12 x 2" SMS 12' O/ C (internal) COVER END PANEL 040 x 3" BEAM PER PL U-header" 2) 1/ 4" THRU-BOLT COL. PER PI AN WHERE MIDPOINT ALTERNATES FOR DECK ATTACHMENT COL. IS INDICATED SMB -PER DETAIL B CHAIR RAIL PER PLAN FASTEN PER DE AI 1/8" X 3" RECEIVING CHANNEL WHERE PAVERS ARE PRESENT INSURE 2) 1/4" X 2" QUICKSET INTO CONC. PENETRATION INTO UNDERLYING CONC. OF 1 1/2" MI 2) #14 X 9/16" EIS COL. WHERE KICK PLATE IS INDICATED 1/8" X 2 X 2 X COL SIZE ANGLE FASTEN W/# 10 X 9/16" SMS. 2) 1/4" X 2" QUICKSET INTO CONC. 8" O/ C AT PERIMETER 2)#14 X 9/16" E/S COL. FORWOODDECKALL. .. FASTENERS TO DECK 1/4" X 2 1/2" GALV. LAG BOLT DETAIL: SCREEN ROOM FRONT WALL SCALE: NTS 4 t 153 q% I fferx 64 Ins Land Surveyors 769 Douglas Avenue, Altamonte Springs, Florida 32714 (407)788-8808 Aismber of the Ronda Swveykfg and kf pm Soo* and Ameriean congress on Surveying and MwPbs Map of Survey Lot 152> 0 Tract A' dk1` y- t Tract C' ty Drainage & Retention } 1, , ` f ' Ar -7- La115B or Lot 160 N 89'57104' W 190.00 425. 50 N 89 57'04' W 494.74 PCP CIL River Landing Drive 34' R/W)Tract B•Access RV I- 2—r-.36 DESCRIPTION y E G DEPT. Lots5M, 157, 158, 159, 6 v n Riverview Townhomes Phase ll', acmdng b Me plat 8f mass ramided in p)at book 75 atPoWs) 51- 58 offtpudfic minds aSemkrola CMW Raride Ok to install screen room with 3" elite panel FLOW p" z'RD°"T"n"p.°"st.%-lammhes WdnFbodZ w'X' as shown on plan. The a000rd gA) Me Flood ksNartda Rafe Map Mwx#*P&W —rber roof on existing slab g 12aMOOWded& 2&2W7. screen enclosure shall be constructed with Food zone debmltrw W way perbrmW byVWW PbMV 6om Food AbflaMsurMwwwwpwknnsdbY same design, material and style as the others in ku sAsmhWspmdbyFM& Mrs find b dewn"Ous zone. The emdzone bcabon an my be &*mdned krardaf &v&% g the nearby and adjacent building. byanabvaBonsWdy. µy&ssaranomspons)b Genets/ NoDas. pR OPO$ED 1. ThisisaBOUNDARY &,.w eikrmed kr the field avl Lewd ew ZNo. aaln.sudaea orsubsrbm u&W aa end krro b nft orralyorary earMwk aRa rR.W ftexk saswrrd M'" J sto N/8cooter r encmachumts ff WW, were bamd. I &O* 4 Bes showy are to ON Ww wUnfanaw b,aWWW 31HUM or MafbOard. Pe Pbt800k Do r. ' aa'Ok PcFbW a OLnuhn 4. Ebvsfions shown hereon, eany are asaamed and ware obbbed from approved a cabal orfDegf Argfa PM!k> K of Conhowld Cuwbaa P.nm GP. Aemarc "Wpo" CNIIU fw PWs P'ded by Ma Gems Unless 00MWIaa /kind and am MWM CALC Calafabd wW b dep,d Ma pmposid oracW dBfieencs if ekwadw mAsUve to the aBE~ ce Crord 9- ft RAr fMMnWO RaftmWe AAxaamm S T7ls par0els areA au[yeClto ae eess/nenl; rs+YefiOr>S, reSkfcYlona. end C".N C.W'Cho'd.*Abnurwnt P "ua P. O. B. f LaELEV SWRO nrMP-0W Po"Orowwwwp R1QAtftsm ydreoofdwydePcWtarotOnMd=HnenL No waxh of fie FWAL EL Bmeaon (Aeeepss4 P.O. C. orCO rmv orne r PuW Raanb has been made by Mrs office. paw AL fbrtorA,ere2& C POW dAsensLtwbsed The IWd d850V rt at101m haW is as Amd$hed by chant RLF! Ba. Fvsened FbW8wehon Fr.PRC 7. PWdad and owaaured dbferwrs end c0mchons are the same UMM oalerwim noted I.P. son Pips p 8. copias or Ms SNvey may be made forfhe ariOmi i ins0on aW LR ban Rd RAD Rbdd tba DwWss X' kw rod wah pbsfic cap marked L840.37, orM' ion red wO L AMLWVMRE3 rid pNsae eap nfarked'WBfeaa Corner•. urMass atAerw,Ise noted d BeaMa apy-area Ls Land&.. yer BY r Banc+wark I Derwde P.C-P. (Fbrmawrd corard paidl Abe Abaauad TIMM Dafotes ParnerferR RererBrfca MonuoleM NOW) AW aw Disk -Alf- Fanw+3 ' ' f ad O 20r211a/ x d AasoWbs brc Al rpMa reaMved N.R No R." ,K ( F&M wave pas daaiq) klstwW.Alkovt rd 0. ,A d..•r Dma fry GM . of* peaasad9nrywsW Chwindby. DLP dw " Prapvsd Aar. AN Norxa N SWXW*• uW terACada r Sketch of Legal Description Job Number. 07- 00.0 sak 1'-,W This is Not a Surrey pfbWbt Udf 01"-11 rod 51" D1vasL prare:rLka . PauNa am fatal safYey kn A AMMWN tnc. $1W&&FbX Rovftb= TOTAL P.01 PreventionCityofSanford Building and Fire Product Approval Specification Form Permit # Project Location Address 2730 River Landing Drive Sanford, FL 32771 As required by Florida Statute 553.842 and Florida Administrative Code 9N-3, please provide the information and product approval number(s) on the building components listed below if they are to be utilized on the construction project for which you are applying for a building permit. We recommend that you contact your local product supplier should you not know the product approval number for any of the applicable listed products. Be aware that windows, skylights, and exterior doors must be tested in accordance with the Florida Building Code, Section 1714.5. More information about Statewide Product Approval can be obtained at www.floridabuilding.org. The following information must be available on the jobsite for inspections: 1. This entire product approval form 2. A copy of the manufacturer's installation details and requirements for each product. Category / Subcategory Manufacturer Product Description Florida Approval # include decimal 1. Exterior Doors Swinging Sliding Sectional Roll U Automatic Other 2. Windows Single Hun Horizontal Slider Casement Double Hun Fixed Awning Pass Through Projected Mullions Wind Breaker Dual Action Other June 2014 Category / Subcategory Manufacturer Product Description(including Florida Approval # decimal 3. Panel Walls Siding Soffits Storefronts Curtain Walls Wall Louver Glass block Membrane Greenhouse E.P.S Composite Panels Other 4. Roofing Products Asphalt Shingles Underla ments Roofing Fasteners Nonstructural Metal Roofing Wood Shakes and Shingles Roofing tiles Roofing Insulation Waterproofing Built up roofing System Modified Bitumen Single Ply Roof Systems Roofinq slate Cements/ Adhesives / Coating Liquid Applied Roofing Systems Roof Tile adhesive Spray Applied Polyurethane Roofing E.P.S. Roof Panels Elite Aluminum Corp 3" foam core 5500-R4.1 Roof Vents Other June 2014 Category / Subcategory Manufacturer Product Description Florida Approval # include decimal 5. Shutters Accordion Bahama Colonial Roll u Equipment Other 6. Skylights Skylights Other 7. Structural Components Wood Connectors / Anchors Truss Plates Engineered Lumber Railing Coolers/Freezers Concrete Admixtures Precast Lintels Insulation Forms Plastics Deck / Roof Wall Prefab Sheds Other 8. New Exterior Envelope Products Applicant's Signature Applicant's Name Please Print) June 2014. Pow 441.,D G . 61iFl 5 st-CR ax Florida Building Code Online https:Hfloridabuilding. org/pr/pr_app_dtl.aspx?param=wGEV XQwtDq... a7:c+ra asa i erot a Business & rofessional RegufalIion rA f}8 'Ii liBbUT lei:8- 81! BCIS Home I Log In I User Registration I Hot Topics I Submit Surcharge I Stats & Facts I Publications I FBC Staff I BCIS Site Map a a f} Product Approvalr . USER: Public Userdo Product Approval Menu > Product or Application Search > Application List > Application Detail FL # FL5500-R4 Application Type Revision Code Version 2014 Application Status Approved Comments Archived Product Manufacturer Elite Aluminum Corporation Address/Phone/Email 4650 Lyons Technology Parkway Coconut Creek, FL 33073 954)949-3200 dk@dokimengineering.net Authorized Signature Frank Bennardo frank@engexp.com Technical Representative Bruce Peacock Address/Phone/Email 4650 Lyons Technology Parkway Coconut Creek, FL 33073 954)949-3200 bpeacock@elitealuminum.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Metal Roofing Compliance Method Evaluation Report from a Florida Registered Architect or Florida Professional Engineer 11Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed Frank L. Bennardo, P.E. the Evaluation Report Florida License PE-0046549 Quality Assurance Entity QAI Laboratories Quality Assurance Contract Expiration Date 12/31/2018 Validated By Jorge A. Pomerantz, P.E. Certificate of Independence Validation Checklist - Hardcopy Received FL5500 R4 COI Indep.pdf 1 of 2 5/30/17, 12:04 PM Florida Building Code Online https:Hfloridabuilding.org/pr/P _app_dtl.aspx?param=wGEVXQwtDq... Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Summary of Products Florida Licensed Professional Engineer or Architect FL5500 R4 Equiv Equiv.pdf 104.11.2 1709.3 Method 2 Option B 02/26/2015 03/08/2015 03/09/2015 04/15/2015 FL # I Model, Number or Name I Description 5500.1 I Aluminum / Aluminum Roof Panels l EPS Foam Core Composite Patio Roof Panels Limits of Use Installation Instructions Approved for use in HVHZ: No FL5500 R4 II Dwg.pdf Approved for use outside HVHZ: Yes Verified By: Frank L. Bennardo, P.E. PE00465 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: For outdoor patio construction only. For use outside FL5500 R4 AE Eval.pdf the HVHZ. See installation drawing for allowable span/load FL5500 R4 AE NOA 11092607.pdf combinations. FL5500 R4 AE Test _Reports l.pdf FL5500 R4 AE Test Reports_2.pdf Created by Independent Third Party: Yes Back Next Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Ref Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records requ electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1: Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you Chapter 455, F.S., please click here . Product Approval Accepts: MM EC heik Credit Card Safe 2 of 2 5/30/17, 12:04 PM EPS FOAM CORE ROOF PANELS ALUMINUM / ALUMINUM SKIN J MAXIMUM ALLOWABLE CLEAR SPAN TABLES: 3" Panels 4" Panels 6" Panels Live Load Deflection 0.024" 0.032" 0.024- I 0.032" 0.024" 1 0.032" tor Upliftl Limit Alum Skin Alum Skin Alum Skint Alum Skin Alum Skin Alum Skin I 1-lb EPS 1-Ib EPS 1-Ib EPS 1-Ib EPS 14b EPS 1-lb EPS 1OP-f 1 L / 120 14'-0" 16'-3" IT-O" 19'.0" 23'-2" i 23'-9" 12 psf L / 120 13'-2" 15'-3" 1T-12" 1T-11" 21'-1" 22' S" 14 Ps f L 1120 12'-7" 14' 6" W'-V 17.-0" 20'-8" 21'4" 16 Psf L 1120 11'-12" IT-10" 16'-4" 16-3" 191AT 20'4" 18 Psf L / 120 11'-6" 13'-4" 15'-8" ! 15'-8" 19'-0" 19W" 20 psf L / 120 11'-2" 12'-10" 15'-2" 16-l" 18'-4" I 18,-11" 24 psf L 1120 10'-fi' 12'-l" 14'-3" 1 14'-3" 17'-3" i T-5" 28 psf 1 120 9'-11" 11' 6" 13-5" 13'-6" 16'-5' 1 16'-2" 32 Psf L / 120 T-3" 1 V-0" IT-S" 12'-7" 15'.5" 1 15'-1" CLEAR SPAN TABLE USE INSTRUCTIONS: 1. DETERMINE TYPE OF ENCLOSURE TO BE COVERED (OPEN, SCREENED WALLS, OR FULLY ENCLOSED), 2. DETERMINE THE SITE SPECIFIC REQUIRED DESIGN WIND PRESSURE PROVIDED BY SEPARATE ENGINEERING, BY A LICENSED ENGINEER OR REGISTERED ARCHITECT, IN ACCORDANCE WITH THE FLORIDA BUILDING CODE FIFTH EDITION (2014). 3. FIND ALLOWABLE COMPOSITE PANEL CLEAR SPAN IN TABLES FOR APPROPRIATE PANEL DEPTH, FACING THICKNESS, AND EPS CORE DENSITY SELECTED. SEAL JOINT CONTINUOUS ` CAULKING I l- awp 000000aoo o°aoo a0000 CROSS SECTION AT TYPiCAr1A19ECiNTERCOCK EPS ROOF PANEL SPAN DETAIL: 0.024" OR 0.032" ALUM 4' MAX WIDTH PER INTERLOCKING PANELTOP & BOTTOM FACINGS (1/4" PER FOOT MIN SLOPE) DEFLECTION NOTES: 1. USE L/120 FOR ALL MEMBERS SUPPORTING ROOFS OVER AN OPEN OR SCREEN -WALLED ROOM. 2. USE L/180 FOR ALL MEMBERS SUPPORTING ROOFS WITH A NON -PLASTERED CEILING OVER AN ENCLOSED ROOM. 3. USE L/240 FOR ALL MEMBERS SUPPORTING ROOFS WITH A PLASTERED CEILING OVER AN ENCLOSED ROOM, PER FLORIDA BUILDING CODE FIFTH EDITION (2014) TABLE 1604.3. OTHER CONSIDERATIONS: 1. FRONT OVERHANG MAY BE UP TO 3'-0" WITH VALUES LISTED HEREIN. MAXIMUM UNSUPPORTED SIDE OVERHANG IS 25% OF LAST PANEL WIDTH (i.e. 12" MAX FOR 48" PANEL WIDTH). 2. ROOF PITCH SHALL BE AS PER BUILDING CODE REQUIREMENTS CLEAR SPAN (L) INSIDE TO INSIDE PANEL REFER TO ADDITIONAL ENGINEERING SHEETS DEPTH FOR To ROOF CONNECTIONS, &SUPPORTING STRUCTURE DETAILS (BY OTHERS). THIS SHEET CERTIFIES ALLOWABLE ROOF SPANS ONLY. OPTIONAL GUTTER OR DRIP CAP 36" MAX O/H AT FRONT & 25% OF LAST PANEL WIDTH AT SIDES UP TO 12" MAX O/H AT SIDES) aaacaliti lt+lierr,,,!/ ' I,a/JBEPdNAk MAXIMUM ALLOWABLE DESIGN PRESSURES: AS NOTED IN CLEAR SPAN TABLES l'ATE DESIGN NOTES: 'F POSITIVE AND NEGATIVE DESIGN PRESSURES CALCULATED FOR USE WITH F r 11r THIS SYSTEM SHALL BE DETERMINED BY OTHERS ON A JOB -SPECIFIC 4,Np>8rc` 1 ClJj `r101 E zBASISINACCORDANCEWITHTHEGOVERNINGCODE. SITE -SPECIFIC rrnn O PRESSURE REQUIREMENTS AS DETERMINED IN ACCORDANCE WITH ASCE 7-10 AND CHAPTER 1609 OF THE FLORIDA BUILDING CODE FIFTH EDITION w ^, W VJ ] w P U 0 J3 2014) SHALL BE LESS THAN OR EQUAL TO THE POSITIVE OR NEGATIVE Z f}.. w DESIGN PRESSURE CAPACITY VALUES LISTED HEREIN FOR ANY ASSEMBLY L > G w a AS SHOWN. a = m W 0GENERALNOTES: z% 1. THIS SPECIFICATION HAS BEEN DESIGNED AND SHALL BE booW FABRICATED IN ACCORDANCE WITH THE REQUIREMENTS OF THE FLORIDA BUILDING CODE FIFTH EDITION (2014) FOR USE OUTSIDE THE HVHZ. COMPOSITE ROOF PANELS SHALL COMPLY WITH CHAPTER 7 SECTION 720, V7 y aCHAPTER8SECTION803, CLASS A INTERIOR FINISH, AND CHAPTER 26 SECTION 2603 OF THE FLORIDA BUILDING CODE FIFTH EDITION (2014). p CONTRACTOR SHALL INVESTIGATE AND CONFORM TO ALL LOCAL BUILDING a CODE AMENDMENTS WHICH MAY APPLY. DESIGN CRITERIA BEYOND AS ySTATEDHEREINMAYREQUIREADDITIONALSITE -SPECIFIC SEALED ENGINEERING. 2, NO 33-1/3% INCREASE IN ALLOWABLE STRESS HAS BEEN USED IN 3 THE DESIGN OF THIS SYSTEM, 3, THE ARCHITECT/ENGINEER OF RECORD FOR THE PROJECT iSUPERSTRUCTUREWITHWHICHTHISDESIGNISUSEDSHALLBEzZ o RESPONSIBLE FOR THE INTEGRITY OF ALL SUPPORTING SURFACES TO THIS DESIGN WHICH SHALL BE COORDINATED BY THE PERMITTING f...l O z CONTRACTOR. 4. SEPARATE 'SITE -SPECIFIC SEALED ENGINEERING SHALL BE i- i F- 0 Q z k LL p x LL REQUIRED IN ORDER TO DEVIATE FROM LOADS, DEFLECTIONS, OR SPANS J U Y O V' CONTAINED HEREIN. LINEAR INTERPOLATION OF THE ALLOWABLE SPAN Q ~ TABLES LISTED HEREIN SHALL NOT BE PERMITTED. CONTACT THIS O Z OwENGINEERFORALTERNATESPANCALCULATIONSASMAYBEREQUIRED. 5. THE SYSTEM DETAILED HEREIN IS GENERIC AND DOES NOT PROVIDE INFORMATION FOR A SPECIFIC SITE. FOR SITE CONDITIONS DIFFERENT w 0 zO U uki f o O j z FROM THE CONDITIONS DETAILED HEREIN, A LICENSED ENGINEER OR J O o a w OU 0-0 REGISTERED ARCHITECT SHALL PREPARE SITE SPECIFIC DOCUMENTS FOR W V 0 u gUUSEINCONJUNCTIONWITHTHISDOCUMENT. THE CONTRACTOR SHALL CAREFULLY CONSIDER POSSIBLE IMPOSING a O p (- 6. LOADS ON ROOF, INCLUDING BUT NOT LIMITED TO ANY CONCENTRATED LULOADSWHICHMAYJUSTIFYGREATERDESIGNCRITERIA. THIS ADDITIONAL ROOF LOAD CRITERIA SHALL BE PROPERLY ANALYZED BY A c 0 G 0 O LICENSED ENGINEER OR REGISTERED ARCHITECT. a7, EPS CORE COMPOSITE PANELS SHALL BE CONSTRUCTED USING TYPE 3105-H354 ALUMINUM FACINGS, EXPANDED POLYSTYRENE FOAM SHALL c vt p w w HAVE TYPICAL DENSITY OF 1.0 PCF AND SHALL BE MANUFACTURED BY DYPLAST PRODUCTS, LLC PER MIAMI-DADE NOA #11-0926.07 (OR Q W a CURRENT VERSION OF THIS NOA. THE EPS FOAM SHALL BE ADHERED TO THE ALUMINUM FACING WITH ISOGRIP SP 202 ADHESIVE (BY ASHLAND SPECIALTY. FABRICATION SHALL BE IN ACCORDANCE WITH APPROVED FABRICATION METHODS BY MANUFACTURER FOR ALL PANELS, INSULATES.THE CONTRACTOR IS RESPONSIBLE TO OR PROTECT ALL MEMBERS FROM DISSIMILAR MATERIALS TO PREVENT ELECTROLYSIS. o a S @ 9. ENGINEER SEAL AFFIXED HERE TO VALIDATES STRUCTURAL DESIGN m AS SHOWN ONLY. USE OF THIS SPECIFICATION BY CONTRACTOR, et. al. INDEMNIFIES & SAVES HARMLESS THIS ENGINEER FOR ALL COST & d DAMAGES INCLUDING LEGAL FEES & APPELLATE FEES RESULTING FROM MATERIAL FABRICATION, SYSTEM ERECTION,& CONSTRUCTION PRACTICES BEYOND THAT WHICH IS CALLED FOR BY LOCAL, STATE, & FEDERAL CODES a v rc c 3 FROM DEVIATIONS OF THIS PLAN. i 10. EXCEPT AS EXPRESSLY PROVIDED HEREIN, NO ADDITIONAL CERTIFICATIONS OR AFFIRMATIONS ARE INTENDED.'e@ 11. ALTERATIONS, ADDITIONS, HIGHLIGHTING, OR OTHER MARKINGS TO LL R5 THIS DOCUMENT ARE NOT PERMITTED AND INVALIDATE THIS CERTIFICATION. x v p fn sdNBe TABLE VALUE DERIVATIONS: E13 11 14-a` PANEL PROPERTIES: C0Pn1cnTFWKL85W 14-14381. PANEL STRUCTURAL PROPERTIES DERIVED FROM CERTIFIED TEST REPORTS Nos. HETI-05-1985,-05-1987,-05-1988,-05-1989, 05-1990,-05:1991,-05-1992,-05-1993,-05-1994,-05-1995, 05-1996,-051997,-06-2066,-06-2067,-06-2068,-06-2069, scalE: N.T. s. SAGE DESCRISTION 06-2070,-06-2071,-06-2072,-06-2073, &-06-2074 BY HURRICANE ENGINEERING & TESTING, Inc, 2. PANEL DEAD LOADS HAVE BEEN FACTORED INTO CALCULATIONS FOR GRAVITY LOADS AS WELL AS CALCULATIONS FOR PANEL PROPERTIES. REQUIRED INSPECTION SEQUENCE address: 3"1 3 PUILIDING PERMIT Min Max .. Inspection Description Footer / Setback Stemwall Foundation / Form Board Survey Slab / Mono Slab Prepour Lintel / Tie Beam / Fill / Down Cell Sheathing — Walls Sheathing — Roof Roof Dry In Frame Insulation Rough In Firewall Screw Pattern Drywall / Sheetrock Lath Inspection Final Solar Final Firewall Final Roof Final Stucco / Siding Insulation Final Final Utility Building Final Door Final Window Final Screen Room Final Pool Screen Enclosure Final Single Family Residence Final Building (Other) ELECTRICALPERMIT Min Max Ins ection Descri tion Electric Underground Footer / Slab Steel Bond Electric Rough T. U.G. Pre - Power Final Electric Final Min Max Inspection DeselCi tion Plumbing Underground Plumbing Sewer Plumbing Tub Set Plumbing Final miCHAIVICAi, . PERMIT . Min Max Ins ection Description Mechanical Rough Mechanical Final min 1Max Gas Unde Gas Roug Gas Final REVISED: June 2014