517 Myrtle Ave; 17-2821; WINDOW REPLACEMENTSEA' CITY OF SANFORD BUILDING & FIRE PREVENTION PERMIT APPLICATION Application No: / 9' d 4 Documented Construction Value: $ 000 Job Address: S rl Historic District: Yes,® No Parcel ID: Residential Commercial Type of Work: New Addition Alteration Repair Demo Change of Use Move Description of Work: EQtJo\ 5 tXO DO-V8"w OCW Plan Review Contact Person: Title: Phone: 140-(- ZG5 - 'Zq 14 Fax: Email: V6 l (3gS It Q 0. 93 , (-a-I Property Owner Information I - Name rfA- ICE QELQ 6L'rY2S Phone: 4Cq— ZSCc - 2q (4- Street: )V? y (L t Resident of property? : ES City, State Zip: 5&M Name Street: City, State Zip: Name: Street: City, St, Zip: _ Contractor Information Phone: Fax: State License No.: Architect/Engineer Information Phone: Fax: E-mail: Bonding Company: Mortgage Lender: Address: Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: 5" Edition (2014) Florida Building C , 5 Revised: June 30, 2015 Permit Application NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal. The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value, credit will be applied to your permit fees when the permit is issued. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done ' liance with all applicable laws regulating construction and zoning. 1'y) C7 /z` // I Signature of Owner Agent Date I Signature of Contractor/Agent Date Owner/Agent is Personally KjwNkn to Me or Produced ID Type of ID L_ e - evd S//7 Print Contractor/Agent's Name Signature of Notary -State of Florida Date Contractor/ Agent is Personally Known to Me or Produced ID Type of ID BELOW IS FOR OFFICE USE ONLY Permits Required: Building Electrical Mechanical Plumbing[] Gas Roof Construction Type: Total Sq Ft of Bldg: Occupancy Use: Min. Occupancy Load: New Construction: Electric - # of Amps Fire Sprinkler Permit: Yes No # of Heads APPROVALS: ZONING: c , 2-g OJT LITIES: Flood Zone: of Stories: Plumbing - # of Fixtures Fire Alarm Permit: Yes No WASTE WATER: ENGINEERING: FIRE: BUILDING: 'F t1-i6-t? Revised: June 30, 2015 Permit Application JWmnon, CFA ps LscwatoouTV. a.ocmw Parcel Information PMPe[j . Record Card Parcel: 25-19-30-5AG-0705-0100 Owner: MACPHEE JAMES W & GIBBS DENNY H Property Address: 517 S MYRTLE AVE SANFORD, FL 32771 Parcel 25-19-30-5AG-0705-0100 Owner MACPHEE JAMES W & GIBBS DENNY H Property Address 517 S MYRTLE AVE SANFORD, FL 32771 Mailing 517 S MYRTLE AVE SANFORD, FL 32771-1820 Subdivision Name SANFORD TOWN OF Tax District S1-SANFORD DOR Use Code 0102-SINGLE FAMILY - SANFORD HISTORICAL DISTRICT Exemptions 00-HOMESTEAD(2000) o Legal Description LOT 10 BILK 7 TR 5 TOWN OF SANFORD PB 1 PG 59 Taxes Taxing Authority County General Fund Schools City Sanford SJWM(Saint Johns Water Management) County Bonds Value Summary 2017 Working 12016 Certified Values Values Valuation Method Cost/Market Cost/Market Number of Buildings 1 1 Depreciated Bldg Value 86,717 83,459 Depreciated EXFT Value 1,113 1,145 Land Value (Market) 19,380 15,390 Land Value Ag Just/Market Value ** 107,210 99,994 Portability Adj Save Our Homes Adj $32,812 $27,126 Amendment 1 Adj P&G Adj $0 $0 Assessed Value $74,398 $72,868 Tax Amount without SOH: $1,191.09 2016 Tax Bill Amount $673.96 Tax Estimator Save Our Homes Savings: $517.131TRIMNoticeHelp Does NOT INCLUDE Non Ad Valorem Assessments Seminole County GIS _3 irl Assessment Value Exempt Values 74,398 74,398 74,398 74,398 74,398 Taxable Value 49,398 25,000 25,000 49,398 49,398 25,000 49,398 25,000 49,398 25,000 Sales Description Date o Book Page Amount Qualified Vac/Imp WARRANTY DEED WARRANTY DEED WARRANTY DEED WARRANTY DEED 9/1/1999 5/1/1999 3/1/1995 4/1/1993 03731 1584 03664 1907 02898 0985 02573 0439 86,000 72,500 67,900 42,000 Yes Yes Yes Yes Improved Improved Improved Improved Land Method Frontage Depth Units Units Price Land Value FRONT FOOT & DEPTH 57.00 117.00 0 340.00 1 $19 380 Building Information Is Bed/Bath count incorrect? Click Here. http://parceldetaii.scpafl.org/ParcelDetailinfo.aspx?PID=2519305AGO7050100 9/20/17, 2:05 PM Page 1 of 2 C I agree that, as the party legally and financially responsible for this proposed construction activity, I will abide by all applicable laws and requirements that govern owner -builders as well as employers. I also n understand that the construction must comply with all applicable laws, ordinances, building codes, and zoning regulations. I am of aware of construction practices and I have access to the Florida Building Codes. I understand that I may obtain more information regarding my obligations as an employer from the Internal Revenue Service, the United States Small Business Administration, the Florida Department of Financial Services, and the Florida Department of Revenue. I also understand that I may contact the Florida Construction Industry Licensing Board at 1-850-487-1395 or at www.myflorida.com/dbpr/pro/cilb/ for more information about licensed contractors. I am aware of, and consent to, an owner -builder building permit applied for in my name and understand that I am the party legally and financially responsible for the proposed construction activity at the address listed below. I agree to notify the building department immediately of any additions, deletions, or changes to any of the information that I have provided on this disclosure or in the permit application package. Licensed contractors are regulated by laws designed to protect the public. If you contract with a person who does not have a license, the Construction Industry Licensing Board, the Department of Business and Professional Regulation and the building department may be unable to assist you with any financial loss that you sustain as a result of a complaint. Your only remedy against an unlicensed contractor may be in civil court. It is also important for you to understand that, if an unlicensed contractor or employee of an individual or firm is injured while working on your property, you may be held liable for damages. If you obtain an owner -builder permit and wish to hire a licensed contractor, you will be responsible for verifying whether the contractor is property licensed and the status of the contractor's workers' compensation coverage. Property Address: 1 7 i. S 0yr2-R_C A JE I, 7 1-y t s do hereby state that I am qualified and capable of performing the requested construction involved with the permit application filed and agree to the conditions specified above. Signature of Owner -Builder Form of Identification Must be Photo ID) Date A violation of this exemption is a misdemeanor of the first degree punishable by a term of imprisonment not exceeding 1 year and a $1,000.00 fine in addition to any civil penalties. In addition, the local permitting jurisdiction shall withhold final approval, revoke the permit, or pursue any action or remedy for unlicensed activity against the owner and any person performing work that requires licensure under the permit issued. Rev. 9.14.2009 C OWNER BUILDER STATEMENT/AFFIDAVIT Altamonte Springs, Casselberry, Lake Mary, Longwood, Oviedo, Sanford, Seminole County, Winter Springs Florida Statutes are quoted here in part for your information to indicate the authority for exemptions for homeowners from qualifying as contractors and to express any applicable restrictions and responsibilities. OWNERS MUST PERSONALLY APPEAR AT THE BUILDING DIVISION TO SIGN THIS DOCUMENT BY SIGNING THIS STATEMENT, I ATTEST THAT: (Initial to the left of each statement) I understand that state law requires construction to be done by a licensed contractor and have applied for an owner -builder permit under an exemption from the law. The exemption specifies that I, as the owner of the property listed, may act as my own contractor with certain restrictions even though I do not have a license. I understand that building permits are not required to be signed by a property owner unless he or she is responsible for the construction and is not hiring a licensed contractor to assume responsibility. I understand that, as an owner -builder, I am the responsible party of record on a permit. I understand that I may protect myself from potential financial risk by hiring a licensed contractor and having the permit filed in his or her name instead of my own name. I also understand that a contractor is required by law to be licensed in Florida and to list his or her license numbers on all permit and contracts. I understand that I may build or improve a one -family or two-family residence or a farm outbuilding. I may also build or improve a commercial building if the costs do not exceed $75,000. The building or O residence must be for my own use or occupancy. It may not be built or substantially improved for sale or lease. If a building or residence that I have built or substantially improved myself is sold or leased within in 1 year after the construction is complete, the law will presume that I built or substantially improved it for sale or lease, which violates this exemption. I understand that, as the owner -builder, I must provide direct, onsite supervision of the construction. I understand that I may not hire an unlicensed individual person to act as my contractor or to supervise persons working on my building or residence. It is my responsibility to ensure that the persons whom I employ have the licenses required by law and by city ordinance. I understand that it is a frequent practice of unlicensed persons to have the property owner obtain an owner -builder permit that erroneously implies that the property owner is providing his or her own labor and materials. I, as an owner -builder, may be held liable and subjected to serious financial risk for any injuries sustained by an unlicensed person or his or her employees while working on my property. My homeowner's insurance may not provide coverage for those injuries. I am willfully acting as an owner - builder and am aware of the limits of my insurance coverage for injuries to workers on my property. I understand that I may not delegate the responsibility for supervising work to a licensed contractor who is not licensed to perform the work being done. Any person working on my building who Is not licensed must work under my direct supervision and must be employed by me, which means that I must comply with laws requiring the withholding of federal income tax and social security contributions under the Federal Insurance Contributions Act (FICA) and must provide workers' compensation for the employee. I understand that my failure to follow these laws may subject me to serious financial risk. Rev. 9.14.2009 Revision City of Sanford Response to comments 1l1 Lol Building & Fire Prevention Division I Z . Ph: 407.688.5150 Fax: 407.688.5152 Email: building@sanfordfl.gov Permit - vM a 1 Project Address: M w Contact:. Ph: Submittal Date. OUA.- f— Fax: Email: Q 1 Trades encompassed in revision: General description of revision: Building Plumbing Electrical Mechanical Waste Water ROUTING INFORMATION Department Approvals Utilities Waste Water Planning Engineering Fire Prevention Building 0M FIRE DEPARTMENT PLAN REVIEW COMMENTS Building & Fire Prevention Division Application Number: 17-2821 Date: 10/05/2017 Project Description: Windows/Siding Contact Name: Denny Gibbs Job Address: 517 S Myrtle Ave Contact Email: DGibbsl(&lI.rr.com This is a general overview for code compliance in accordance with the minimum plan review required by the Florida Building Code. It is not a complete detailed review. The comments noted in this review must be addressed before the plans can be approved. Changes to plans shall be submitted on the same size format as the original submittal — changes in letter form are not permitted. All references to FBC Chapter 1 are as amended by City of Sanford ordinance viewable on our website at www.sanfordfl.gov. Provide two copies of affected plan sheets and/or supplemental information as requested. Permit submittals will not be accepted without two copies. COMMENTS: 1. The permit application description of work states "remove old window and replace with new jeld-wen windows (2)". The Certificate of Appropriateness grants approval to "place windows on east elevation and decrease the size of the window opening. Further clarification is required as to the exact scope of work that will be conducted at this property. If you are simply swapping out windows, size for size (meaning no openings are being modified), then the only requirement needed to achieve a plan review approval is two copies of a floor plan showing the exterior walls and the location and size of the windows being replaced. This floor plan can be hand -drawn. If you are modifying a window opening, signed and sealed engineering from a design professional will be required as this is considered a structural modification. The engineering must include all framing requirements needed to modify the opening. In addition, a floor plan will also be required showing the location of the window replacements and modification. FBC 107 2. The permit application description of work also states to replace bad siding. Please provide an exterior wall floor plan (same as above) showing the location of the siding replacement. FBC 107 No Review has been conducted* Any error or omission in this plan review shall not be construed to grant approval of any violation of any of the adopted codes or municipal ordinances of this jurisdiction. Office meetings with the plans examiner to discuss comments will require an appointment, arranged by phone or email prior to arrival. Respectfully, Steve Fiorey, CBO Residential Plans Examiner M! RC Engineering, LLC Residential, Commercial, Multi -Family Consulting Engineering 2381 Crest Ridge Ct November 14, 2017 Sanford, FL 32771 407-474-9181 Fax 407-328-5397 City of Sanford Building Department 300 North Park Ave Sanford, Florida 32771 Re: Gibbs Residence 517 So. Myrtle Ave Dear Building Official: The following responses address your comments from review letter dated 10/5/17. 1) See attached engineered plan showing location and size of window replacement. See plan's scope of work The new windows will require larger openings, see plan. Plans are signed and sealed for new window openings. 2) See plan for window installation, siding replacement and floor plan. The Jeld Wen Window installation instructions has been included (FL. Approval 17594.4). Please call Jack Reynolds at 407-262-9176 or me at 474-9181 if you have any questions. Sincere 4 Dd# A@ e i4/$ooRoo e i a s a!,5 , LPL nse #:5K590 a 9 STATE OF% 0OOOOD0000 'k gip J RC Engineering, LLC 407-474-9181 FAX 407-688-1898 City of Sanford r 5 Historic Submittal Guidelines F U Window & Door Replacement The following information is meant as a general guideline to assist with meeting Florida Building Code and Historic Preservation requirements when replacing or altering windows or doors on a home or business located in the Sanford Historic District. GENERAL RULES FOR HISTORIC PRESERVATION COMPLIANCE A Certificate of Appropriateness must be applied for prior to obtaining a Building Permit FLORIDA BUILDING CODE COMPLIANCE If Florida Product Approval cannot be obtained due to the proposed window or door being custom made or refurbished, the following alternative method is required: A product -evaluation report or certification based upon testing or comparative or rational analysis, or a combination thereof, developed and signed and sealed by a Florida professional engineer or Florida registered architect, which indicates that the product complies with the code. 553.8425(1)(d) Florida Statute The following information must be included on the submittal from the engineer or architect: Detailed and dimensioned drawing of the window or door Installation requirements for the window or door (type and size of fasteners, spacing of fasteners) Substrate of existing structure where window or door will be installed Maximum design pressure (positive & negative) of the window or door Signed and sealed The following statement must also be provided by the engineer or architect: The (window/door) has been designed to meet ultimate wind speed of 139mph and complies with current Florida Building Code requirements." Revised: September 2016 REQUIRED INSPECTION SEQUENCE Address: OUILIDING (PERMIT Min Max .. Inspection Description Footer / Setback Stemwall Foundation / Form Board Survey Slab / Mono Slab Prepour Lintel / Tie Beam / Fill / Down Cell Sheathing — Walls Sheathing — Roof Roof Dry In Frame p Insulation Rough In Firewall Screw Pattern Drywall / Sheetrock Lath Inspection Final Solar Final Firewall Final Roof Final Stucco / Siding Insulation Final Final Utility Building Final Door Zo 3o Final Window Final Screen Room Final Pool Screen Enclosure Final Single Family Residence Final Building (Other) Min Max Ins ection Descri Lion Electric Underground Footer / Slab Steel Bond Electric Rough T.U.G. Pre -Power Final Electric Final 1, t . 1 v. tM X 1 •/;{ C at.:y n.r.. 1.ax;,s ys,y_l v{,i9';a[/+H^ m q `.i f , T.4Kl'.blG M ?pV' i• _ 'Y:'??.,r`. °' Min Max Inspection Descri Lion Plumbing Underground Plumbing Sewer Plumbing Tub Set Plumbing Final e Inspection Description Mechanical Rough i ..:$ ( p• i...ylllrvw,1,;'41. j a•. t i 5 j7j'i; Tx«7«. P f"vYe. [iAt G" l_ n .N 5 PK 30 [Z rc r i £i °:" 1 n^fi ' (i':,. y :v 1 C r .. ,..>. j1 ,:ry£. 7 i•'v (i•7 :r• r;'i„ ..f•G ram'•.4,`if:l, L^s;,.n'1 1:_t'.a"+riC,7/?fLi.IL•...1 t iC, 3.5:sT.:..7f3._.u.S fn.o.'+..1.:.._c•ti msecfion _ _ . . 4110- REVISED: June 2014 r-- KITCHEN l r- DECK i EMOVE (3)WINDOWS ND INSTALL (2) EW WINDOWS LAUNDRY ROOM BATHROOM — HISTORIC PERMIT All work must be done in strict accordance with the Approved Certificate of Appropriateness wilding does not approve any work outside this scope permit Applicant is coley responsible for compliance RECORD COPY LIVING ROOM DINING ROOM 1,200 S.F. HOUSE FRONT PORCH 130' CLO ETS ` r— I III OFFICE BEDROOM II II ATHROOM 40'-0" EXISTING HOUSE FLOOR PLAN Irn,,_ A"=1 ' SANFORD BU11 DING DIVISION I " --- II ;II; Iil; ;I-1---7 SAPS I; ;II I I; ;IPERMITISSUEDSHALLBECONSTRUEDTOBE 1 _ I 1II1 _ _ III I _ I 1 ENSE TO PROCEED WITH THE WORK AND NOTL _ JL _ _ JL _ J AUTHORITY TO VIOLATE, CANCEL, ALTER OR SET SIDE ANY OF THE PROVISIONS OF THE TECHNIC DES, NOR SHALL ISSUANCE OF A PERMIT PREVE NT THE BUILDING OFFICIAL FROM THEREAFTER _ _ L 1 - -LL -JA CORRECTION IN PLANS, OF CONSTRUCTIONEQUIRINGORVIOLATIONSOFTHISCODE— EXISTING REAR ELEVATION & DEMO PLAN i„=1 EXISTING SIDING TO BE REPLAC IN COMPLIANCE WITH CAO EWED POR CODE COMPLIANCE PLANS EXAMINER Ix-k( e-I 1 F,F ;TF_, DATE IIII IIII li ill i i Ili ill i i Ili IL II L___ IILJ NEW 1x6 SIDING (EXTENT TO BE DETERMINED IN FIELD) & COMPLIANCE WITH GAO PROPOSED PLAN 1 3036 WINDOWS SIDING TO REMAIN ROOF & WALL SHEATHING NAILING PATTERN 8D (RING SHANK) NAILS 8" O/C IN FIELD 8D (RING SHANK) NAILS 4" O/C EDGE 1-/2I SHEATHING W/1 x6 SIDING L_ — _ _ — — EXIST. BOT. - --- PLATE 1 PROP. DBL. 2x12 HDR. PROP. WINDOW PROP. SILL I d- H2. 5 CLIP EA. NEW STUD TO PLATE 2) HDR. STUDS & (1) FULL LENGTH STUD EA. SIDE OF OPENING FXLSLF)B1_- IOP_P-1 TF --- RETA I STII[ S OR,IREFRXI I I PROP. DBL. 12x12 HEADER M ')LSTA 12 PER HHSIDE & CENTER\ FRAME OPENING FOR NEW WINDOW n AME OPENING R NEW WINDOV I. EXIST. [ 1 PLATE BOT. ---JJ _____ 1111------ 11______1 ___ill1.11_____]1______ Ill EXIST. BOTTOM PLAT PROP. 2x4 STUDS H3 CLIP EA. NEW 2 SPF, 16"O/C STUD TO PLATE PROPOSED WALL SECTIONS DEMO SCOPE OF WORK 1) REMOVE ( 3) EXISTING WINDOWS AND TRIM 2) REMOVE 1x6 SIDING AND SHEATHING ABOVE AND BELOW WINDOW OPENING. HOMEOWNER TO DETERMINE EXTENT OF SIDING REMOVAL 3) REMOVE ANY ROTTEN 2x4 STUDS, SHEATHING AND SIDING PROPOSED CONSTRUCTION SCOPE OF WORK F-03 I i I I I I I I I I I I I I I I II I I I I I I I I I I 1) FRAME IN NEW OPENING TO ACCOMONDATE (2) NEW 3036 WINDOWS INSTALL WINDOWS PER MANUFACTURERS SPECS. 2) ADD STUDS AS NECESSARY. ALL NEW STUDS TO BE #2 SPF, 16" 0/C. ALL NEW STUDS TO BE CLIPPED TO EXISTING TOP AND BOTTOM PLATES 3) ADD NEW DBL. 2x12 HEADER OVER NEW WINDOW OPENING. USE (2) HEADER STUDS AND ONE FULL LENGTH STUD EACH SIDE OF NEW OPENING. STRAP HEADER TO STUDS W/(2) LSTA 12 EACH SIDE 4) ADD NEW 1 /2" CDX PLYWOOD SHEATHING AND TYVEK OR 1 /2" GREEN BOARD ZIP SYSTEM) W/O TYVEK. 5) ADD NEW 1x6 SIDING TO MATCH EXISTINGCAULK AND PAINT. EIV e WIND LOAD NOTE I 0 ,.° a` NOV 1 5 2017 THIS STRUCTURE HAS BEEN DESIGNED TO MEET OR EXCEED THE 140 M.P.H.(Vult) WIND wM LOAD REQUIREMENTS OF CHPT. 3 OF THE 2014 ERMOCRATS,CASffLLO, P.E. DATE FLORIDA RESIDENTIAL BLDG. CODE, 5th ED. FL. REG. # 52590 o E 8 Z 0 E Fr E FT oHLLrn E QCO c7 o0 J toF LU Ujo0v U = p 0 d' a. N ~ J M Q H LL W 8 U Z Q tl Z Q W M to moo Q OJZo Z=" Z F- WOE O 000 0 0 z z rj) w Z E U. a DESIGNED: JHR I REVIEWED BY: RC SCALE: 1 /4"=1' DATE: 11 /12/17 Al 1 OF 1. VL # 1-15g4.4 4" MAX. 16" O.C. MAX. FROM THRU FRAME CORNERS 1 1 H F H F H (r I WINDOW WIDTH 45.375" MAX.) 16" O.C. MAX. TYe 9THRUit FRAME 1 C6 yR I Tog,' Is Rai b g co TYPICAL ELEVATION WITH FASTENER SPACING MIN. DISTANCE FROM EDGE: 3/4" 1 2X WOOD FRAME 2 1 1/4" MIN. EMBEDMENT 4" MAXSHIMSPACE CLAD FRAME SECTION (TYP) TF'rIl' VERTICAL SECTION Installed Fastener Schedule: 1. Seal flange/frame to substrate. 2. All windows: install corrosion resistant #8 fasteners no more than 4" from each corner and 16" o.c. through the nail fins on all sides of the window. Fasteners must be long enough to penetrate at least 1 1/4" into framing members. a 0 0 This schedule addresses only the fasteners required to anchor the window to achieve the rated design pressure up to the size limitations noted. It is not intended as a guide to the installation process and does not address the sealing consideration that may arise in different wall conditions. For the complete installation procedure, see the instructions packaged with the door or go to www.jeld-wen.com/resources/installation. DISCLAIMER: This drawing and its contents are confidential and are not to be reproduced or copied in whole or in part or used or disclosed to others except as authorized by JELD-WEN Inc. MAXISPACE 2X WOOD FRAME THROUGH FRAME INSTALLATION 1 1/4" MIN. 1/4" MAX EMBEDMENT SHIM SPACE 2X WOOD FRAME 2 MIN. DISTANCE FROM EDGE: 3/4" FRAME JAMB SECTION (TYP) 1 HORIZONTAL SECTION Frame oo„s"Max DP Ratin Impact 45 3 8" x 92" 35 NO General Notes: 1. The product shown herein is designed, tested and manufactured to comply with the wind load criteria of the adopted International Building Code (IBC), the International Residential Code (IRC), the Florida Building Code (FBC) and the industry standard requirement for the stated conditions. 2. Buck, framing and masonry by others and is responsibility of architect or engineer of record. 3. All glazing shall conform to ASTM E1300. 4. At minimum, glazing shall be double strength annealed insulating glass. ROJECi ENGINEER: DATE: 01/19/2015 3737 Lakeport Blvd RAWN BY: SCALE: JEL&WENKIamath Falls, OR. 97601 D. Vezo NTS Phone: (541) 882-3451 Jones Siteline Wood Double Hung Window PDbP1204b IDENTIFIER Na. PLANT NAME AND LCIG4TION: N/A Rantoul, IL This Instrument Prepared By Lonnie N. Groot, Esquire Stenstrom, McIntosh, Colbert, Whigham, P.A. 1001 Heathrow Park Lane, Suite 4001 Lake Mary, Florida 32746 Return To: Ms. Christine Dalton Community Planner/Historic Preservation Officer Planning and Development Services Department City Hall 300 North Park Avenue Sanford, Florida 32771 Tax Parcel Identification Number: 25-19-30-5AG-0705=0100. s ssss ,ss ssae_< n;sss s,s s s `i is.s a lD i11 17 1 M. O i O l i'II FL.,fUMPT EM" PC CLERK'S `1 201 7075400 1 Irla.0F, I - HISTORIC PERMIT theAllworkmustbedoneinstrictaccordance Approved Certificate of Appropriateness Building does not approve any work outside this scopePemtitApplicantissoleyresponsibleforcompliance HISTORIC PRESERVATION BOARD OF THE CITY OF SANFORD DEVELOPMENT ORDER RELATING TO 51.7 SOUTH MYRTLE AVENUE AND ISSUING CERTIFICATE OF APPROPRIATENESS On June 21, 2017, the Historic Preservation Board of the City of Sanford issued this Development Order issuing a Certificate of Appropriateness relating to and touching and- concerning the following described property: 517 South Myrtle Avenue, Seminole County Tax Parcel Identification Number: 25-19-30-5AG-0705-0100. FINDINGS OF FACT Property Owners: James W. Macphee and Denny H. Gibbs 517 South Myrtle Avenue Sanford, Florida 32771 Applicant: Denny H. Gibbs 517 South Myrtle Avenue Sanford, Florida 32771 Project: To place windows on east elevation and decrease the size of the, window opening on the real property located at 517 South Myrtle Avenue. - Requested Development Approval: To place windows on east elevation and decrease the size of the window opening on the real property located at 517 South Myrtle Avenue. - J LDING Additional Findings: None. OFPAR- HISTORIC PERMIT All work must be done in strict accordance with the Approved Certificate of AppropriatenessCONCLUSIONSOFLildingdoesnotapproveanyworkoutsidethis scope Permit Applicant is soley responsible for compliance a). Under Schedule "S" of the. City's Land Development Regulations as set forth in the Code of Ordinances of the City of Sanford, windows, frames, glass, muntins, mullions, sills, lintels and pediments in good condition or repairable and in character with the style and period of the building shall be retained. Window types that are no longer permitted by law, such as jalousies, may be replaced with another style of window that is in character with the style and period of the building. (S-33). The existing windows are not original and are not in character with the period of the building. If windows or window details are determined to be irreparable, they may be replaced provided that on the primary facades of contributing buildings, replacement windows shall match .the existing original windows in size; configuration, material, design and placement. A window survey and specifications for each window must be submitted with the Certificate of Appropriateness application. On secondary facades, replacement windows may be of a different design or type provided the windows are consistent with the style of the building. (S-33). The proposed windows are consistent with the style of the building. Only when a change is .appropriate to the style and period of the building may a window be relocated,, enlarged, reduced or introduced. (S-33). The reduction of the window opening is appropriate to the style and period of the building. When replacing existing windows that are inappropriate to the style and period of the building, they shall be replaced with new windows that are appropriate to the style and period of the building. (S-33). The proposed windows are appropriate to the style and period of the building. Windows on additions shall have the same orientation and be of a similar size to the existing or original windows of the principal fagade except if the addition is HISTORIC PERMIT All work must be done in strict accordance witl Approved Certificate of Appropriatettoss Building does not approve any work outside this on the same plane as the existing principal fagade, then the wind8 ik dk4en rdditilDtVsponsibteforcompli shall match the original windows in orientation, size, materials and configuration. (S-33). The proposed windows are similar to the original windows in orientation, size, materials and configuration. Windows shall be proportioned such that the height shall be equal to or greater than the width, with the exception of historically, appropriate window groupings. (S-34).The proposed windows are in a historically appropriate grouping. b). The purpose and intent of Schedule "S" have been met in the context of the approval set forth herein. c). To the extent that a conclusion of law as set forth herein also constitutes a factual finding, then such shall be taken to be so as part of this Development Order d). The proposed Certificate of Appropriateness is hereby found and determined to comply with the aforestated requirements. e). Additionally, the Certificate of Appropriateness sought is hereby found and determined to be consistent with the City of Sanford Comprehensive Plan and development of the property as proposed would be consistent with and in compliance to applicable land development regulations and all other applicable regulations and ordinances as set forth in the Code of Ordinances. of the City of Sanford. A0 NOW, THEREFORE, IT IS ORDERED THAT: 1). The aforementioned application for a Certificate of Appropriateness is APPROVED. 2). Development shall occur in accordance with the provisions of Schedule S" of the City's Land Development Regulations as set forth in the Code of Ordinances 3 of the City of Sanford. HISTORIC PERMIT All work must be done in strict accordance with the Approved Certificate of Appropriateness Building does not approve any work outside this scope Permit Applicant is soley responsible for compliance 3). This Development Order touches and concerns the aforedescribed subject real property and shall be a burden that runs with and burdens the subject real property and all matters set forth herein may be enforced by any code enforcement process available to the City. Done and Ordered on the date first written above. As approved and authorized for execution by the Historic Preservation Board of the City of Sanford at its meeting of June 21, 20.17. ATTEST.'' . alpB' G HISTORIC PRESERVATION BOARD OF THE CITY OF SANFORD yl ry .- f ' f Tam A ni , Chai anCynisPorter, City C lrk F y 9 Date: 1g -1 i City Seal ' n F r' -- Nunc pro tunc to June 21, 2017. Witness: Jennifer Go way PROPERTY OWNERS SIGNATURE BLOCK FOLLOWS: HISTORIC PERMIT All worts must be done in strict accordance with the Approved Certificate of Appropriateness Building does not approve any want outside this scope Permit Y PROPERTYY WN for cot tiatece JOINDER AND APPROVAL OF CONDITIONS BY P IN WITNESS WHEREOF, the subject Property Owner has signed and sealed these presents, through its authorized officer and representative, the day and year written below and AGREES to all of the terms and conditions of this Development Order approving a Certificate of Appropriateness. ATTEST.' JAMES W. MACPHEE AND DENNY H. GIBBS STATE OF FLORIDA ) COUNTY OF SEMINOLE The foregoing was sworn to and subscribed before me this2lLday of June, A.D. 2017, by James W. Macphee and Denny H. Gibbs, who are personally known to me or who produced A.9n identification. WITNESS my hand and official seal in the C my and State aforesaid this Z-w day of June, A.D. 2017. JENNIFER M. GOLLOWAY Notary Public - State of Florida My Comm. Expires Nov 3, 2017 Commission FF 043230 N ota ry P l is Nglor`il Norte' Assn. My Commission Expires: 5 fiilS INSTRUMENT PREPARED BY: Address: NOTICE OF COMMENCEMENT GRANT MALOYf SEMINOLE COUNTY - CLERK OF CIRCUIT COURT t, COMPTROLLER State of Flori BK 9031Ps 452 (1 P3 S ) County of emin/ol e ,c a ?i1 7 Permit Nu ber: I L ( rcel ID Number: B ev w_- o i5 FG to certain real property; The undersig d hereby gives notice provement will be made and in accoraalt owing information is provided in this Notice of Commencement. Chapter713, Flo g ' . ••• -. 4; nESCRIPTION OF PROPERTY: (Legal de rip of the property and street address if available)n DESCRIPTION OF OWNER INFOEMATION: ' p Name: Address: Fee Simple Title Holder (if other than owner) Name: Address: CONTRACTOR: / Name: Address: Persons within the State of Florida Designated by Owner upon whom notice or other documents may be served as provided by Section 713.13(1)(b), Florida Statutes. Name: Address: of In addition to himself, Owner Designates To receive a copy of the Lienor's Notice as Provided in Section 713.130)(b), Florida Statutes. Expiration Date of Notice of Commencement (The expiration date is 1 year from date of recording unless a different date is specified) WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENTARECONSIDEREDIMPROPERPAYMENTSUNDERCHAPTER713, PART 1, SECTION 713.13, FLORIDASTATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICEOFCOMMENCEMENTMUSTBERECORDEDANDPOSTEDONTHEJOBSITEBEFORETHEFIRSTINSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORECOMMENCINGWORKORRECORDINGYOURNOTICEOFCOMMENCEMENT. Under enalties of perjury, I declare that I have read the foregoing and that the facts stated in it are true tot a best f my knowledge and belief. S Owners Signature Owner' s Pnmed Name 1 The owner must sign the notice of commencement and no one else may be permitted to sign in his or her stead' FloridaStatute713.13(1)(g): - ''0 1yM State of _ County of t z The foregoing instrument was acknowledged before me this 6 day of l e m i . Ile- 20 1 ' o w by U I Who is personally known to me m w Q i Name of person making statem t 7 " m OR who has produced identification type of identification produced: 1, q cn y w. C, 0 arrr4q, k s" "s••, ANNETTE BLAND °' c = 0 Notary Public - State of FloridaUo w n Commission # GG 060623 Notary Signature W oafs My Comm. Expires Jan 16. 2018 rr