Loading...
2549 Palmetto Ave; 18-3777; GENERATORo SEP Ai9 PERMIT APPPLICATION Application No: Documented Construction Value: $— Job Address:6 P(10 w 90 ^ J' Parcel ID: Historic District: Yes NO[] • fj(04 CID Residential Commercial ElTypeofWorkNew dition Alteration [I RepairRe t P [IDemon Change of Use ElMove Description of Work: Plan Review Contact Person: Title: Phone: Fax: Email: P erty Owner InformationName~ 1 a t.3'hdne: Street 4 '\t'\T Resident of property? : City, State Zip: I I Contractor Information Name s42 ,,_} W ci ( '2ri L- Co Ir Phone:— 407 - Z2- 16, Street: F W11 Fax: 07-33—l76 City, State Zip: ? 71 State License No.: Architect/ Engineer Information Name: —_ ;/ UliQ Phone: Street: Fax:. City, St, Zip: E- mail: Bonding Company: !// % y', Mortgage Lender: _ / yy Address: Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICEFORIMPROVEMENTSTOYOURPROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior totheissuanceofapermitandthatallworkwillbe,perform ed to meet standards of all laws regulating construction in this jurisdiction. I understand thataseparatepermitmostbesecuredforelectricalwork, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: 6ie Edition (2017) Florida Building Code NOTICE: In addition to the requirements of this permit, there maybe additional restrictions applicable to this property that maybe found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713 The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated construction value of the)ob at the time of submittal. The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in accordance with local ordinance. Should calculated charges figured ,off the executed contract exceed the actual construction value, credit will be applied to your permit fees when the permit is issued. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. CS S- q A_TA_WU N-0 na re of Contractor/Agent e Print Contractor/Agent's Name Signature of Notary -State of Florida Date Contractor/Agent is _ Personally Known to Me or Produced ID Type of ID BELOW IS FOR OFFICE USE ONLY Permits Required: Building Electrical Mechanical Plumbing Gas Roof Construction Type: Occupancy Use: Flood Zone: Total Sq Ft of Bldg:_ Min. Occupancy Load: # of Stories: New Construction: Electric - # of Amps Plumbing - # of Fixtures Fire Sprinkler Permit: Yes No # of Heads Fire -Alarm Permit: Yes No APPROVALS: ZONING: UTILITIES: WASTE WATER: ENGINEERING: FIRE: BUILDING: COMMENTS: Ok to install generator as shown on plan meets area and dimension regulations for MR-2 zoningdistrict. O/'?/LV 10 SCPA Parcel View: 01-20-30-506-0000-0490 i,,cra Property Record Card Parcel: 01-20-30-506-0000-0490 rco avry r1csrA Property Address: 2549 S PALMETTO AVE SANFORD, FL 32771 Parcel Information Value Summary Parcel 01 20-30 506-0000-0490 -- 2018 Working = ValuesOwner(s) CAMERON, RICHARD R Values CAMERON, JOAN A Valuation Method Cost/Market Cost/Market Property Address 2549 S PALMETTO AVE SANFORD, FL 32771 — - Number of Buildings Mailing 2549 S PALMETTO AVE SANFORD, FL 32773-5143 Depreciated Bldg Value i $60,253 $52,625 Subdivision Name WOODRUFFS SUBD FRANK L--— — - - Depreciated EXFT Value $3,821 $3,871 Tax District S1-SANFORD Land Value (Market) $22,000- $166,000___w____- 000 DOR Use Code 01-SINGLE FAMILY -- Land Value Ag Exemptions 00-HOMESTEAD(1994) Just/Market Value ** ; $86,074 ; $72,496 Portability Adj i Save Our Homes Ad l $18,601 $6,411 Amendment 1 Adt $0 n Cn P&G Adj $0-$O__..--- --- _--- i Assessed Value- !--85 -_- 66,085 f Tax Amount without SOH: $623.00 2017 Tax Bill Amount 581.00 i Tax Estimator Save Our Homes Savings: $42.00 C) e TRIM Notice ,Help 59d* Does NOT INCLUDE Non Ad Valorem Assessments Legal Description LOTS + 51 w_._---.-- FRANK L WOODRUFFS SUBD PB 3 PGG 44 Taxes Taxing Authority I Assessment Value Exempt Values County General Fund 67,473 ; 42,473 Schools 67, 473 ' 25,000 City Sanford__-_- 67,473 i 42,473 SJWM( Saint Johns Water Management) 67, 473 42,473 County Bonds 67, 473 42,473 Sales Description Date Book Page Amount Qualified WARRANTY DEED 8/1/1978 01184 1085 18,500 No arind C ra I s Land Method Frontage Depth U 't Taxable Value 25; 000 42 473 251000 25; 000 25, 1000 Vac/ Imp y Improved ni s LOT Units Price Land Value j 0.00 ' ' 0.00 '. 1 j $22,000.00 22,000 Building Information Is -- _ _ Bed/B h c Lrgct? Click Here Description Year Built eclive P Fixtures Bed Bath Base Area Total SF Living SF Ext Wall Adj Value Repl Value Appendages Actual/Eff I- -- - - - — 1 SINGLE 1955/1958 6 3 2.0 ,` 1,268 1,856 . 1,604 j CONIC$60,253 FAMILYBLOCK $ 102, 559 Description Area http://parceldetail.scpafl.org/Parcel Detail I nfo.aspx?PI D=01203050600000490 1/ 2 f lu- 17 1Cnnrt7S Ln74Zn/n4n rn-7^, ..,. P 2/5 SIB_ l a.rfiiQ2!{c - j STATE zw L• Yu — !>. Gr C1 C Y 1 2vr r e rs ! J ea.f,.:-, r=+•a ., p i .'`, ^ { ,p„ ! •lSb. 0 ar NOyfCE TO CUSTOMER — P E CALCULATIONS: In order to properly perlortn the installation of certain Gonda, the Contract Prxe may include moreGoodsthen COnt a will be iulatedd based on the me isurad square footage of the Project Area. As a result, the parties agree that the lump -sum PricestatedinthisContrasiscalculateduponboththevalueofestimatedGoodsrequiredtofulfilltheContract (including waste), which may emceed theodualsquarefaolageoftheProjectArea, and the labor which may be estimated based On the amount of Goods required to fulfill the Contract (including waste), no signing this Contrail below, Customer ices ar per raceipt Of this notice and agrees and understands that the Price includes these costs which maynotberefundedoncetheInstallationServicesareperformed. NOTICE TO CUSTONIER• r-ederal tayr requires Lowe s to11 provide you with thePamphletRenovateRight13ysigningthisContras, Customer acknowledgeshavingreceivedacopyofthispamphletbeforeworkbeganinformingCustomer Contract Total of the potential risk of the lead hamrd exposure from renovation activity to be •applicable taxes included ri) ` f' t rrfomtedinCustomer'$ dwelling unit. . ; terra . .- NOTE: If rotted woo is discovered during inst Iatton a (tonal c agges wi 1 apply. You will be given a quote and a change ordermustbecompletedandsfgredbytinecustomerforanyadditionalcharges. Customer must initial. My want or material not specified l9 not Included in this contract,. Any changes or additions will be at an addiaonel charge for the me niit and tabor. NOTICE TO OWNER: - ACCORDING TO FLORIDA'S CONSTRUCTION LIEN LAW {SECTIONS 713.001-713.37, FLORIDASTATUTES , THOSE WHO WORK ON YOUR PROPERTY OR PROVIDE MATERIALS AND SERVICES AND ARE NOT PAID INFULLHAV A RIGHT TO ENFORCE THEIR CLAIM FOR PAYMENT AGAINST YOUR PROPERTY. THIS CLAIM IS KNOWN AS ACONSTRUCTIONLIEN. IF YOUR CONTRACTOR OR A SUBCONTRACTOR FAILS TO PAY SUBCONTRACTORS, SUB -SUBCONTRACTORS, OR MATERIAL SUPPLIERS, THOSE PEOPLE WHO ARE OWED MONEY MAY LOOK TO YOURPROPERTYFORPAYMENT, EVEN IF YOU HAVE ALREADY PAID YOUR CONTRACTOR IN FULL. IF YOU FAIL TO PAY -YOURCONTRACTOR, YOU R CONTRACTOR MAY ALSO HAVE A LIEN ON YOUR PROPERTY. THIS MEANS IF A LIEN IS FILED YOURPROPERTYCOULDBESOLDAGAINSTYOURWILLTOPAYFORLABOR, MATERIALS, OR OTHER SERVICES THAT YOURCONTRACTORORASUBCONTRACTORMAYHAVEFAILEDTOPAY. TO PROTECT YOURSELF YOU SHOULD STIPULATEINTHISCONTRACTTHATBEFOREANYPAYMENTISMADE, YOUR CONTRACTOR IS REQUIR 6 TO PROVIDE YOU WITH AWRITTENRELEASEOFLIENFROMANYPERSONORCOMPANYTHATHASPROVIDEDTOYOUA "NOTICE TO OWNER" FLORIDWS CONSTRUCTION LIEN LAW IS COMPLEX, AND IT IS RECOMMENDED THAT YOU CONSULTAN ATTORNEY. PHOTO RELEASE: Customer grants to LowiI and Lowe's employees end Independent contractors the right to take photographs of the Premises whereInstallationServiceswillbeperformedandanworkperformedatthePremisesrelatedtothisContract, and Irrevocably grants to Lowe's all right, Site andinterestinandtothephotographsforuseinallmarketsandmedia, worldwide, in perpetuity. Customer authorizes Lowe's to copyright, use and publish thephotographsinprintand/or eiectronicaliy, and agrees that10I may use such photographs foe any lawful purpose, inducing, but not limited to, marketsadvertising, publicity, Illustration, training and Web content. By Initialling here, Customer agrees to the foregoing. [Customer to initial to the ten). Work is to corgrneltca upon reasonable availability of Contractor and/or any special order omer made d(s) which Is anticipated to be till In date]. Estimated completion date Is— [till in date]. Said estimated subslantiat completion &Ant,of Ihe•asse A t meM apy Wltingencles that ki'n_ wteAaltyl change said saiirq$ted substantialcompletiondateIsasfotlowat_s3r ?., tr of aAc", Insert a statement of sdiikii cwntingencles). This Contract provides that all claims by Customer or Lowe's will be resolved by BINDING ARBITRATION. Customer and Lowe's GIVE UP THE RIGHTTOGOTOCOURTtoenforcethisContras (EXCEPT for matters that may be taken to SMALL CLAIMS COURT). Lowe's and Customer's rights will bedeterminedbyaNEUTRALARBITRATORandNOTajudgeorjury. Lowe's and Customer are entitled to a FAIR HEARING. But the arbitration procedures are SIMPLER AND MORE LIMITED THAN RULES APPLICABLE IN COURT. Arbitrator decisions are as enforceable as any court order andaresubjecttoVERYLIMITEDREVIEWBYACOURT. FOR MORE DETAILS: Review the section titled ARBITRATION AGREEMENT, WAIVER OF JURY TRIAL. AND WAIVER OF CLASS ACTION ADJUDICATION found In the Terms and Conditions of this Contract. DO NOT SIGN THIS CONTRACT UNTIL COMPLETE AND YOU HAVE READ THE TERMS AND CONDITIONS CONTAINED ON ALL PAGES OF THIS CONTRACT. BY SIGNING BELOW, YOU ARE ACKNOWLEDGING THAT YOU HAVE READ, UNDERSTAND AND AGREE TO THE TERMS AND CONDITIONS SET FORTH ON ALL PAGES OF THIS CONTRACT. YOU ARE ENTITLED TO A COPY OF THIS CONTRACT AT THE TIME OF SIGNATURE. a ... iWITNESSOURHANDS) AND SEAL(S) BELOW THIS DAY OF Lowe's Home Centers, LLC lavner Lcwe's Authored Representative Co-owner 6r Witness i>- --1-- a u•p Fy ui "-Gunc wncnwas compitmw mea in prior to Customers execution hereof. You, the buyer, may Ancelthistransactionatanytimepriortomidnlghtofthethirdbusinessdayafterthedateofthistransaction. See the attached notice of cancellation nn for an explanation of this right REV. , 12113 FILE COPY o 2004 by L ."'1161 8111''s*w, amrpn m meMeW umlom eft a LF wryonoxi. . Grant Maloy, Clerk Of The Circuit Court & Comptroller Seminole County FLInst #2018101530 Book:9204 Page:1030; (1 PAGES) RCD: 9/5/2018 2:46:16 PM REC FEE $10.00 vrRTll'' M t OIN (AN" CLERK, t THE (JRCl'IT CiJtJF,T 84('dD0 4PT rRvt'.:R THIS IN TR MENT I' EPARED BY: SE(dlfNOL, - u ! e" f OR Name: Cl ('o" Address: BYJi z Date -- NOTICE OF COMMENCEMENT Permit Number: Parcel ID Number. ^a-3y ' 13l)(0-0buz)- og `icy The undersigned hereby gives notice that improvement will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement. 1. DESCRIPTION OF PROPERTY: (Legal description of the property and street address if available) 2. 3. OWNER INFORMATION OR Name and address: GA Interest in property: Cr4 E INFORMATIONAF THE LESSEE CONTRACTED FOR THE IMPROVEMENT: rToart.. L c it_'+- o25Y9 R.,sJ,.7_%'. `l.x Fee Simple Title Holder (if other than owner listed above) Name: Address: " i) "9 4. CONTRACTOR: Name: Jr rW.1 L-0 Phone Number. 467- 32-2.- is c? Address: / OZ evcol" U%, S&mCa ,rr 37-771 5. SURETY (If applicable, a copy of the payment bdnd is attached): Name: Address:_ y4-11-4 _ Amount of Bond: 6. LENDER: Name: ./Id Phone Number. Address: 7. Persons within the State of Florida Designated by Owner upon whom notice or other documents maybe served as provided by Section 713. 13(1)(a)7., Florida Statutes. Name: /!% 4 Phone Number: 6. In addition, Owner designates of to receive a copy of the Uenor's Notice as provided In Section 713.13(1)(b), Florida Statutes. Phone number. 9. Expiration Date of Notice of Commencement (The expiration is 1 year from date of recording unless a different date is specified) WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART I, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. SiYinature of Owner or Lessee, or Owners or Lessee's (Print Name and Provide Signatory's Tale/Office) Authorized Offim/Dlrector/Partner/Manager) State of County of / f bt Th f e of in nt as acknowledged before me this O day of T' 20 l by f fOkA . Who is personally known tome OR Name of person making statement / who has produced identification type of identification produced: C a- ` % C-4 r/ THOMAS SANDIFORD a?'" •` h MY COMMi0910N #GG126650 tie EXPIRES: JUL 23, 2021 Bonded through 1st State Insurance ff Parcel: 01-20-30-506-0000-0490 Nu y,rUUtNtuttraye.a5px rrlu=U lZUsubUbUUUUU49U&BLDGN0=1&PAGEN0=1 Building No.: 1 Page No: 1 Sketch by Ape„ Sketch RECORD COPY A' 65_- DATE SANFORD BUILDING DIVISION A PERMIT ISSUED SHALL BE CONSTRUED TO BE A ICENSE TO PROCEED WITH THE WORK AND NOT Al ASIDE ANY OF THE PROVISIONS OF THE TECHNICAL CODES, NOR SHALL ISSUANCE OF A PERMIT PREVENT THE BUILDING OFFICIAL FROM THEREAFTER REQUIRING A CORRECTION OF ERRORS IN PLANS, CONSTRUCTION OR VIOLATIONS OF THIS CODE 1 8 - 3 7 7 7 http://parceldetail.scpafl.org/FootprintPage.aspx?PID=01203050600000490&BLDGNO=1 &PAGEN0=1 1/1 Generator Installation Check List Per National Electrical Code, Article 702 OptionalSiandbXS st„ems Contractor. 'ban c-YcL Cv t 1' Property Address A 5 q T AJ vu.e_ ff-6 .4ue SERVICE SIZE A9P5 GENERATOR SIZE c> KW GENERATOR AMPS SWCH TYPE MANUAL Permit #: EXAMPLES: 200 AMPS 20 KW .r 85 AMPS Full pad° Ik 311 d h,Mrhee s a BDA li'sa ° tAne iP ulA.litsd 4An 4rate2ffkmanlymrmmen MOC I[, aeacA sacuaAn>tfi® 4'0 Lew_iew G1Qia®naafi A elErrd ®da* 22083 ]Essus9daaa DvveAUA& uere Feet of Livia Am 60Y S . Ft. Ft. m9 Living Argo x 3va Z Kamn.1pulm a 1 500 Q 60c. Laundri I Sva Range gc vp dater Haler C ishweeber Stothee ® Faces c t ACIAHU Outer 6® ede 1 C First Ob 100% ROOLM 2 4M s alntar Totes a4 5 a 40% 7 EXAMPLES: 3726 S0. Ft 19178 2 Kitchen special @ 3.000 1 Refrigerator 9 500 1 Laund 1500 1 Range Q 8,000 4,500 1,440 960 5, 000 Shedding — Sae Below° 37,078 First Ok 90 1000A m 8,000 Remaining 29078 40% =11,631 19,631 196311240 m 81.79 amps ltvide Load hadding dasCrlotl®n andl®P scbetnnti The A/ C systems are not included in these calculations because they will be added to the load shed portion of the transfer switch. Note: ManualTransferEquipmentNationat,Electricai Code 702.5(8)(1) l Boundary Survey LOT 47 Trw .'71} •' •- :-x-.:.N89°43'46"ELL Q 124.00'(P) y FOUNDIr 1,•FND YIC tiAI,L"'-•.'... - z IRON ROD 124.00'(M PSM 0332 — EN ACHMENT .TON O O Z O C] O O C -f -U O 0to A $ 18.D A In (n N r 02 o ^ 4u !I T RI mP-- ------------- — — — — b $ § i O o 0 0 4.01 20COVERED R7S45 O D I "e DIRT 0 as O' n r r Mg. c:CON 8 O O Z $ M COVERE8.0' DIRT 20.V 4 12r TON ouND , r S89°4346"W 124.00'(P) rP$- M: I? IRON ROD r iS89°42'25"W 124.00'(M) oOD 352LOT 53 z ml 3; 779 FouNo12' r IRON RW . IL SW BLOCK CORNER TROV:U PLANS, t: 7 ,11,r.: Ok to install generator as shown on plan Z meets area and dimension regulations for GRAPHIC SCALE LOT; MR-2 zoning district. D Is D IN PLI )A. BASIS OF BEARINGS: BEARINGS SHOWN HEREON ARE BASED ON THE WEST LINE OF LOTS 49 AND 51, BEING N 00'16'14- W, PER PLAT LIST OF POSSIBLE ENCROACHMENTS: NEIGHBORS CONCRETE ENCROACHES, COVERED CARPORT AND OTHER COVERED AREA EXTEND OFF LOT AS SHOWN DLS #: 18-04-0105 LEGEND FLOOD ZONE INFORMATION CLIENT P.2549 S PALMETTO (FOR INFORMATIONAL PURPOSES ONLY) FIELD DATE: 04124f2018 DRAFTER: CMF MC -Ak Cenddmer P -Pfm APPROVED: BHH C Ca Ia10 PS R. Boek SUBJECTPROPERTY SHOWN HEREON APPEARS TO BE LOCATED IN Ca 11— PG -Pbkdd FLOW ZOIIE X AREA OUTSIDE OF THE 100YEAR FLOOUPLAN, CERTIFIED TO: AS FURNISHED C8-Corerele Bock PI -Poedof Oil.—Abri PER F.I.RM PANEL NUMBER 12117G W70F CM-CaxrNe Monometd POB of BeSeedng JOAN CAMERON CON C-ConvNe Poe •POlntolc—eno Nd LAST REVISION DATE D=82 7 RICHARD CAMERON COV -Covered PP -Power Pd. D- Deecdo'W PRC -Pokd orRevmse CurvaWre DE Dreb geEe—em PRM -Perr—ttRee m SURVEYOR'S CERTIFICATE DUE- Diaheq &MYEvm R NOTES ES DdvevraY RAD -Radkd 1 HEREBY CERTIFY THAT THIS SKETCH OF SURVEY WAS MADE UNDER MY t . var6lwm> pim.mtM ESMT- Eeseroenl RyC _Ry8 RESPONSIBLE CHARGE AND TO THE BEST OF MY KNOWLEDGE AND BELIEF SAID Ned. FFE - FkdW dFbv Eleva4n RFD -R." SURVEY MEETS THE MNMUMTECHNM-.AL STANDAP.DS SET FORTH BY THE FLORIDA xk: u+roYrc"b,FAGmCI;-4mil+e.Ikob°l e,..ee nnuv FM " FOB UE - LWW Easma,i BOARD OF PROFESS"AL LAND SURWVM. i1 CHARTERS-17FLORIDA M 1tmmmtl muYbW,NnMmN as waywantlmappmA'm4M.ttM P -Le 7ti (Arc} 'A • Watx M,..' ADMINISTRATIVE CODE. FURTHER, THIS DOCUMENT IS ELECTRONICALLY SKV UAND evevmm• M krNi e"°nrA,.a M • Measured ' Della (Ge," A.96) SEALED PURSUANT TO SECTION 472.027 OF THE FLORIDA STATUTES AND CHAPTER l Wurdarppumlmp°wm"n v°wm,na vmn lrsm Mels m.wY. N8D •NBDSDsk-WoodIPVC Fvica SJ-17 OF THE FLORIDA ADMINISTRATIVE CODE uHen " imrabe rose NR -N-FR d a - Char LhkFmm Tw avwrampH me. a..e roramauwnpvp°.. OHU :0-heed UdMYLIne 4 r""•^^011"e1`w4 O°i"'0I'^'FP°"^F ORS -Ontdd Record. Book DATE OF FIELD WORK: 04/2412/118 \ Pmpmryewavadm.tl°rmMe.rom.... pnyaGeyrvame DATE SIGNED: 04I26/2018 c. nree n...,e kAamrmn .. nova W rc1 e, wwymma`mam,e sem.nakna..,em."., rc) " 4 , m.m mw.a k, aw raMT ma P«a 4m. y.ak r f Mm,. Aupen) t'F rme,(mmm,WOt'H r44Y SURVEYOR'S NAME: BILL KWATT 154636 mm . Ar mm m we° mPw cow DEAL LAND SURVEYING, LLC LB 8121 MmavkvapnadypeM• rneay rokrDer aia,.redm p4v ; mdb M°h+amarwvN, yeptM.Nb x nvYy.dm.._y ropy k,ep4ae,• rcpm,i MPmrt FOR ALL INQUIRIES CONTACT: ne°'" wineybnuAiO v"°°""'"ia wbau1tlioiavjieport°' Deal Lend Serveyl.%, LLC NOT VAUD WITHOUT AN AUTHENTICATED ELECTRONIC SIGNATURE TITS SURVEY IS PREPARED FOR THE EXCLUSIVE $04SF—Avenue AND AUTHENTICATED ELECTRONIC SEAL USE AND BENEFIT OF THE PARTIES LISTED HEREON. Sanford, FL 32711 DATE REVISION DATE REVISION LIABILITY TO THIRD PARTIES MAY NOT BE 407.673.3726 TRANSFERRED OR ASSIGNED. INF00helande—yk,q— 16 20 22 kW INCLUDES: True Power" Electrical Technology Two Line LCD Multilingual Digital Evolution TM Controller (English/Spanish/ French/Portuguese) Two Transfer Switch Options Available: 100 Amp Pre -Wired Switch or 200 Amp Smart Switch. See Page 4 for Details. Electronic Governor GENERAL' akllmm GUARDIAN® SERIES Residential Standby Generators Air -Cooled Gas Engine Standby Power Rating Models 006459-0, 006461-0, 006462-0 (Steel - Bisque) - 16 kW 60 Hz Model 006721-0 (Aluminum - Gray) - 16 kW 60 Hz Models 006729-0, 006730-0 (Steel - Bisque) - 20 kW 60 Hz Models 006551-0, 006552-0 (Aluminum - Gray) - 22 kW 60 Hz External Main Circuit Breaker, System Status & Maintenance Interval LED Indicators GFCI Duplex Outlet Sound Attenuated Enclosure Flexible Fuel Line Connector Composite Mounting Pad Natural Gas or LP Gas Operation 5 Year Limited Warranty Capability to be installed within 18" (457 mm) of a building* c STED us LISTQ QUIEHEST- Note: CUL certification only applies to unbundled units and units packaged with pre -wired switches. Units packaged with the Smart Switch are UL certified in the USA only. Only if located away from doors, windows and fresh air intakes, and unless otherwise directed by local codes. FEATURES O INNOVATIVE DESIGN & PROTOTYPE TESTING are key components of GENERAC'S success in "IMPROVING POWER BY DESIGN." But it doesn' t stop there. Total commitment to component testing, reliability testing, environmental testing, destruction and life testing, plus testing to applicable CSA, NEMA, EGSA, and other standards, allows you to choose GENERAC POWER SYSTEMS with the confidence that these systems will provide superior performance. O SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION. This state-of-the-art power maximizing regulation system is standard on all Generac models. It provides optimized FAST RESPONSE to changing load conditions and MAXIMUM MOTOR STARTING CAPABILITY by electronically torque -matching the surge loads to the engine. Digital voltage regulation at ±1%. O TRUE POWER" ELECTRICAL TECHNOLOGY: Superior harmonics O SINGLE SOURCE SERVICE RESPONSE from Generac's extensive dealer and sine wave form produce less than 5% Total Harmonic Distortion for network provides parts and service know-how for the entire unit, from the utility quality power. This allows confident operation of sensitive electronic engine to the smallest electronic component. equipment and micro -chip based appliances, such as variable speed HVAC systems. O TEST CRITERIA: 0 GENERAC TRANSFER SWITCHES. Long life and reliability are synonymous with GENERAC POWER SYSTEMS. One reason for this PROTOTYPE TESTED NEMA MG1-22 EVALUATION confidence is that the GENERAC product line includes its own transfer SYSTEM TORSIONAL TESTED MOTOR STARTING ABILITY systems and controls for total system compatibility. GENERAC® GENERAC® 16/20/22 kW features and benefits Engine Generac (OHVI) design Maximizes engine "breathing" for increased fuel efficiency. Plateau honed cylinder walls and plasma moly rings helps the engine run cooler, reducing oil consumption resulting in longer engine life. Quiet Test'" Greatly reduces sound output and fuel consumption during bi-weekly exercise, compared to other brands. Spiny-lok" cast iron cylinder walls Rigid construction and added durability provide long engine life. Electronic ignition/spark advance These features combine to assure smooth, quick starting every time. Full pressure lubrication system Pressurized lubrication to all vital bearings means better performance, less maintenance and longer engine life. Now featuring up to a 2 year/200 hour oil change interval. Low oil pressure shutdown system Shutdown protection prevents catastrophic engine damage due to low oil. High temperature shutdown Prevents damage due to overheating. Generator Revolving field Allows for a smaller, light weight unit that operates 25% more efficiently than a revolving armature generator. Skewed stator Produces a smooth output waveform for compatibility with electronic equipment. Displaced phase excitation Maximizes motor starting capability. Automatic voltage regulation Regulates the output voltage to ±1 % prevents damaging voltage spikes. UL 2200 listed For your safety. Transfer Switch Fully automatic Transfers your vital electrical loads to the energized source of power. Pre -wired, color -coded conduits Ensures the easiest, trouble -free installation. Pre -wired switches only) DPM Technology Digital Power Management Technology allows for the smart control of two air conditioners without any additional Smart Switch only) items. Remote mounting Mounts near your existing distribution panel for simple, low-cost installation. Evolution— Controls Auto/Manual/Off illuminated buttons Selects the operating mode and provides easy, at -a -glance status indication in any condition. Two-line LCD multilingual display Provides homeowners easily visible logs of history, maintenance and events up to 50 occurrences Sealed, raised buttons Smooth, weather -resistant user interface for programming and operations. Utility voltage sensing Constantly monitors utility voltage, setpoints 60% dropout, 80% pick-up, of standard voltage. Generator voltage sensing Constantly monitors generator voltage to ensure the cleanest power delivered to the home. Utility interrupt delay Prevents nuisance start-ups of the engine, adjustable 2-1500 seconds from the factory default setting of 5 seconds by a qualified dealer. Engine warm-up Ensures engine is ready to assume the load, setpoint approximately 5 seconds. Engine cool -down Allows engine to cool prior to shutdown, setpoint approximately 1 minute. Programmable exerciser Operates engine to prevent oil seal drying and damage between power outages by running the generator for 5 minutes every other week. Also offers a selectable setting for weekly or monthly operation providing flexibility and potentially lower fuel costs to the owner. Smart battery charger Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature. Electronic governor Maintains constant 60 Hz frequency. Unit SAE weather protective enclosure Sound attenuated enclosure ensures quiet operation and protection against mother nature, withstanding winds up to 150 mph. Hinged key locking roof panel for security. Lift -out front for easy access to all routine maintenance items. Electrostatically applied textured epoxy paint for added durability. Enclosed critical grade muffler Quiet, critical grade muffler is mounted inside the unit to prevent injuries. Small, compact, attractive Makes for an easy, eye appealing installation, as close as 18" away from a building.` Installation System 1 ft (305 mm) flexible fuel line connector Absorbs any generator vibration when connected to rigid pipe. Composite mounting pad Eliminates the need to pour a concrete pad unless required by local municipalities 16/20/22 kW Generator GENERAC® specifications Model 006459-0, 006461-0, 006462- 006729-0, 006730-0, 006551-0, 006552-0 01 006721 0 (16 kW) 20 kW) 22 kW) tWRated MaximumContinuous PowerCapacltyy_(lR) 1fi,000 Watts - 20,D00 Watts` 22,000 Watts* Rated Maximum Continuous Power Capacity (NG) 16,000 Watts' 18,000 Watts' 19,500 Watts` Rated Voltage _ _ _ 240 w 240 Rated Maximum Continuous Load Current — 240 Volts (LP/NG) 66.6/66.6 83.3/75 91.6/81.3 Total Harmonic Distortion Less than 5% Less than 5% Less than 5%( Main Line Circuit Breaker 65 Amp 90 Amp 100 Amp Phase rt M .: 1 1 Number of Rotor Poles 2 m 2 2 Rated AC Frequency 60 Hz 60 Hz 60 Hz + Power Factor 1.0 1.0 1.0 u. B attery Requirement (not included) Group 26R, 12 Volts and 525 CCA Minimum Unit Weight (lb/kg) 513/232.7 (Steel); 448/203.2 (Aluminum) 516/234.1 526/238.6 Dimensions (L x W x H):in/min w 48 x 25 z`29/1218 z638 x 732' l Sound output in dB(A) at 23 If (7 m) with generator operating at normal load" 66 66 67 60m 60 58. Exercise duration 5 min 5 min 5 min Engine Type of Engine GENERAC OHVI V-TWIN GENERAC OHVI V-TWIN GENERAC OHVI V-TWIN Number of Cylinders 2 2 2 Ris lacement PHt 992 cc 999 cc:-_' ` 999 cc Cylinder Block Aluminum w/ Cast Iron Sleeve Valve Arrangement Overhead Valve Overhead Valve Overhead Valve ^ j Ignition System Solid-state w/ Magneto Solid-state w/ Magneto Solid-state w/ Magneto GavernorSystem Electronic-' Electrontd Electronic Compression Ratio 9.5:1 9.5:1 9.5:1 Starter 12 Vdc w 12 Vdc : _ 12 Vdc Oil Capacity Including Filter Approx. 1.9 gt/1.8 L Approx. 1.9 gt/1.8 L Approx. 1.9 gt/1.8 L Operating rpm 3,600 3,600 3,600 Fuel Consumption Natural Gas fta/hr (m3/hr) 1/ 2 Load 193 (5.47) 205 (5.8) 184 (5.21) Full Load 312 (8.83) 308 (8.72) 281 (7.96) Liquid Propane ft3/hr (gal/hr) [I/hr] 112 Load 72.4 (1.99) [7,53] 75.6 (2.08) [7.87] 83 (2.16) [8.16] Full Load 130 (3,57) [13.53] 140 (3.85) [14.57] 127 (3.68) [13.99] Note Fug elpipemustbeszedforfullload. Required fuel pressure to generator fuel inlet at all load ranges3 5; 7 water column (7 13 mm mercury) for natural gas 10 12' water column (19 22 mm_.. -I Controls L2 Line Plarn'Text Multilingual LCD Display M Simple useriiterface for ease of operation. Mode Buttons: Auto Automatic Start on Utility failure. 7 day exerciser. anual M _ Start with starter control, unit stays on. If utility fails, transfer to load takes place. Off Stops unit. Power is removed. Control and charger still operate. T Ready to Run/Maintenance Messages Standard 3 Engine Run Hours Indication Standard Programmable start delaybetween 2.1500 seconds,,:: _ µ Standard (programmable by dealer only) Utility Voltage Loss/Return to Utility Adjustable (Brownout Setting) From 140-171 V/190-216 V Future Set Capable Exerciser/Exercise Set Error Warning Standard Run/ Alarm/Maintenance Logs 50 Events Each Engine Start'Sequence'" ' ° _ ' : 'Cyclic cranking 16 sec•on 7 rest (90"sec maximum duration).' Starter Lock -out Starter cannot re-engage until 5 sec after engine has stopped. Smart Battery Charger Standard Charger Fault/Missing AC Warning Standard Low Batter%/Battery Problem Protection and Battery Condition Indication Standard Automatic Voltage Regulation with Over and Under Voltage Protection Standard Under- Frequency/Overlo d Stepper Overcurrent Protection min Standard i Safety Fused/Fuse Problem Protection Standard Automatic Lowil Pressure/H OighOil Temperature Shutdown _ v+_ _ Overcrank/ Overspeed (@ 72 Hz)/rpm Sense Loss Shutdown Standard Mi, Engines- erature-Shutdown I Standard " t Internal Fault/Incorrect Wiring Protection Standard Common External Fault Ca abilit --. AY „. T r,. w-..,,..„;;,„ n Standards:. Field Upgradable Firmware Standard Sound levels are taken from the front of the generator. Sound levels taken from other sides of the generator maybe higher depending on installation parameters. Rating definitions -Standby: Applicable for supplying emergency power for the duration of the utility power outage. No overload capability is available for this rating. (All ratings in accordance with B55514, IS03046 and DIN6271). *Maximum wattage and current are subject to and limited by such factors as fuel Btu/megajoule content, ambient temperature, altitude, engine power and condition, etc. Maximum power decreases about 3.5 percent for each 1,000 feet (304.8 meters) above sea level; and also will decrease about 1 percent for each 6 T (10 T) above 16 T (60 T). GENERAC® 16/20/22 kW switch options Pre -wired Features available on Steel 16 kW models only Electrically operated, mechanically -held contacts for fast, positive connections. Rated for all classes of load, 100% equipment rated, both inductive and resistive. 2 pole, 250 VAC contactors. 30 millisecond transfer time. Dual coil design. Main contacts are silver plated or silver alloy to resist welding and sticking. NEMA 1 (indoor rated) enclosure is standard on the pre -wired switch. Pre -wired 30 foot (9.1 meter) whip to connect to the provided 5 foot pre - wired whip and external connection box. Pre -wired 2 foot (0.61 meter) whip, color coded to connect into the existing electrical panel. Dimensions Model 006461-0 (16 kW) No. of Poles 2 Current Rating (Amps) 100 Voltage Rating_(VAC) 120/240 10 Utility Voltage Monitor (Fixed)` Pick-up 80% Dropout B0% Return to Utility ,: , t" approx. 15 secl 4, Exercise weekly for 12 minutes' Standard UL Listed Y Standard Total of Pre -wired Circuits 16 No, 15 A 120 V 5 No. 20 A 120 V 5 No. 20 A 240 V 1 No. 30 A 240 V No. 40 A 240 V 1 No. 50 A 240 V 1 Circuit Breaker Protected Available RMS Symmetrical Fault Current 250 Volts@ 10.000 Function of Evolution Controller Mechanical Dimensions Height Width Depth H1 H2 W1 W2 in 23.5 26.4 8.3 12.6 6.3 mm 597 671.7 211 320.7 159.6 Wire Ranges Conductor Lug Neutral Lug Ground Lug 2/0-#14 210-#14 2/0-#14 Smart Switch Features Includes Digital Power Management Technology standard (DPM). Intelligently manages two air conditioner loads with no additional hardware. Up to four more large (120/240 VAC) loads can be managed when used in conjunction with Power Management Modules (PMM"). Electrically operated, mechanically -held contacts for fast, clean connections. Rated for all classes of load, 100% equipment rated, both inductive and resistive. 2 pole, 250 VAC contactors. Service equipment rated, dual coil design. Rated for both aluminum and copper conductors. NEMA/UL 3R aluminum outdoor enclosure. Main contacts are silver plated or silver alloy to resist welding and sticking. Note: PMM starter kit is required prior to using the modules. Dimensions 200 Amps 120/240, 1e Open Transition Service Rated Height Width H1 H2 W1 W2 Depth in 27.24 30.0 11.4 13.5 1 7.09 mm 692.0 1 762.4 289.0 1 343.0 1 180.0 Model 006462.0 (16 kW)/006729-0 (20 kW)/006551-0 (22 kW) No. of Poles 2 Current Rating (Amps) 200 Voltage'Rating_(VAC) a120/240,1010:° Utility Voltage Monitor (Fixed)" Pick-up 80% Dropout 60% IReturn-t'oUtility' W approx. 13sic."'- ®' ' Exercise weekly for 12 minutes' Standard UL Listed n Standard; Enclosure Type NEMA/UL 3R Withstand Rating_(Amps) 22,000 Lug Range 250 MCM - #6 Function of Evolution Controller Wt - H2 Ht sDEPTH I W2 GENERAC® 16/20/22 kW available accessories Model # Product Description Generac's Mobile Link allows you to check the status of your generator from anywhere that you have 006463-1 Mobile Link'" access to an Internet connection from a PC or with any smart device. You will even be notified when a change in the generator's status occurs via e-mail or text message. 005819-0 26R Wet Cell Battery Every standby generator requires a battery to start the system. Generac offers the recommended 26R wet cell battery for use with all air-cooled standby product (excluding PowerPact®). I If the temperature regularly falls below 32 °F (0 °C), a cold weather kit is required to maintain optimal E' 006212-0 Cold Weather Kit battery and oil temperatures. Kit consists of a battery warmer and oil filter heater with built-in thermostats. f 005621-0 Auxiliary Transfer Switch Contact The auxiliary transfer switch contact kit allows the transfer switch to lock out a single large electrical Kit load you may not need. Not compatible with 50 amp pre -wired switches. ! 005839-0 - Bisque Fascia Base Wrap Kit* The fascia base wrap snaps together around the bottom of the new air cooled generators. Thiss offers H 005666-0 - Gray (Standard on 22 kW) a sleek, contoured appearance as well as offering protection from rodents and insects by covering the lifting holes located in the base. 005703-0 - Bisque If the generator enclosure is scratched or damaged, it is important to touch-up the paint to protect 005704-0 - Gray Paint Kit* from future corrosion. The paint kit includes the necessary paint to properly maintain or touch-up a IIr generator enclosure. 006484-0 - 16 kW t Generac's scheduled maintenance kits provide all the hardware necessary to perform complete 006485-0 - 20 & 22 kW Scheduled Maintenance Kit routine maintenance on a Generac automatic standby generator. r Completely wireless and battery powered, Generac's wireless remote monitor provides you with 006664-0 Wireless Remote Monitor instant status information without ever leaving the house. Not compatible with CorePower or EcoGen systems. The PMM Starter Kit consists of a 24 VAC, field installed transformer that enables the use of the 24 006199-0 PMM Starter Kit a VAC Power Management Modules (PMMs)and one PMM. The standard controller (without starter kit) can control two HVAC loads with no additional hardware. Not compatible with pre -wired switchess..--i Power Management Module (50 Power Management Modules are used in conjunction with the Smart Switch to increase its power I 006186-0 Amps) management capabilities. It gives the Smart Switch additional power management flexibility not found in any other transfer switch. Not compatible with pre -wired switches. Note: PMM Starter Kit required. j m.r Note: Bisque kits are used in conjunction with steel enclosures. Gray kits are used in conjunction with aluminum enclosures. 731. 28, dimensions & UPCs Dimensions shown are approximate. Refer to installation manual for exact dimensions. DO NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES. LEFT SIDE VIEW 1218 mr 47.9 in] 1226 mm 48.3 in) - FRONT VIEW Model UPC 006459-0 696471064599 0064610 696471064612 006721-0 696471067217 006729-0 696471067293 006730-0 696471067309 006551-0 696471065510 006552-0 696471065527 006462-0 1 696471064629 GENERAC® Generac Power Systems, Inc. • S45 W29290 HWY. 59, Waukesha, WI 53189 • generac.com 02014 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice. Bulletin OK8458-D Printed in U.S.A. 06/19/14 Transfer Transfer Switches Go Now, SORIO- and non"Oervic_te rated Automat , Smart Transfer .S wi tches 100 - 400 Amps, Single Phase 1111'' b t 8mt1etmIW1is"Omrme naroiaoogrt; TUL only applies to non -service rated switches . Description Generac Automatic Transfer Switches are designed for use with single phase generators that utilize an Evolution- or Nexus - Controller. The 100, 200, and 400 amp open transition switches-.are_available in-sing.le phase in bothservice equipment rated and non -service equipment rated configurations, The 150-and 30.6amp.open transition -switches are only available in a service rated equipment configuration. Standard Features Service rated ( RTSW) Generac Automatic Transfer Switches are housed in an aluminum NEMA/,UL Type 3R enclosure*, with electrostatically appliedandbakedpowderpaint. The Heavy Duty Generac.Contactor is a UL recognized device, designed for years ofservice. The controller at the generator handles all the timing, sensing, exercising functions, and transfer commands. All switches arecoveredbya5yearlimitedwarranty. Non -service rated (RTSC) switches are housed in a steel enclosure. DPM Technology Through the use of digital power technology (DPM), these switches have the capability to manage up to 4 individual HVAC (24 VAC controlled) loadswithnoadditionalhardware. When used in tandem with Smart Management Modules, up to 8 more loads can be managed aswell, providing the most installation efficient power management options available. SO 10.04- 0.0 Amps, Sin! Smart 5 iNIN . Functions _ All timing and sensing functions originate in the generator controller Utility voltage drop -out ................................................ Timer to generator start .............................................................................. ctor...set, ....justble................................................................<60% Engine warm up delay ................................ 10 second factory set, adjustable,between 2-1500 seconds by a qualified dealer* Standby voltage sensor ...........................................................................•............ .5 seconds Utility voltage pidwp.........................................•..............................................................60% fo Re - transfer time -delay ..... for 5.seconds Enginecool - down timer.......•.•..•......................................•...•...••...••..........•.•..•.•.........•..•..........•.....•..............................:....•...•..•.•.•..•.•...••..••,.,.•.......•.....................sewn s Exerciser.•.•...................................................•.••..,.....,...•...............•...........•••.••.....•......•...•.•.•..,...•..••............................................. ..... 15 seconds 60 seconds 12 minutes every 1 days Thetransferswitchcanbeoperatedmanuallywithoutpowerapplied. When used in conjunction with units utilizing Evolution- controls specifications - moaei Amps100 Voltage Load Transition Type Automatic) Enclosure Type YPUL Rating Wi withstandRating RTSC100A3 flTSW10OA3 100 120/ 240.10 120/240,1a Open Transition Open Transition Service Rated NEMANL 3R NEMAAIL 3R UL/ CUL UL RTSW150A3. RTSC200A3 RTSW20OA3 150 200 200 120/ 240, 7a. 120/240,1e 120/240,1m Open Transition Open Transition Open Transition Service Rated Service Rated NEMA/ UL 3R NEMA[UL.3R NEMNUL 3R UL UL/CUL UL RTSW3OOA3 300 120/ 240,1e OpgrlImnsltjon Seivlca Rated RTSC400A3 400 120/ 240,10, RTSW400A3 400 120/ 20, 1e Open Transition Open Transition Service Rated NEMNUL. 3R NEMNUL 3R NEMA[UL 3R UL UL/CUL UL Amps) Lug Range 10, 000 10,000 1/ 0 - #14 22, 000 10,000 22,000 250. MCM - #6 22, 000 22,000 22,000 600 MCM 4 or 1/0 - 250-MOM Dimensions Model RTSC10CA3 RTSW10OA3 MU160A3 RTSC20OA3 RTSW20OA3 RTSW30OA3 RTSC40OA3 RTSW400A3 H1 17,24/437.9 17.24/437.9 28.75/679.4 1724/437.9 26.75/679.4 2.91/MO89.9.31.25/793.8 Height2.91/1089.9 in mm) H2 20/508 20/508 30/762 20/508 30/762 48/1219.2 36/914.4 48/1219.2 Width Wi 12.5/317.5 12.5/317.5 10.5/268.7 12.5/317.5 10.5/266.7 16.69/423.919.18/.487.2 16.69/423.9 In rn) W2 14.6/370.8 14.6/370.8 13.5/342.9 14.6/370.8 13.5/342.9 21.82/554.2 24/609.6 21.82/554.2 Depth ( InJmm) 7.09/180.1 7.09/180.1 UA60.1 7.09/180.1 6.3/16o.1 10.06/255.5 10.06/255.5 10.OW55.5 Weight ( WIC110s) 20/9.07 225/10.21 39/17.69 20/9.07 39/17.69 140/83:5 133/60.33 140/63.5 MRNERACGenerac Power Systems, Inc. • S45 W29290.HWY, 5.9, Waukesha, WI 531,89 • generac.com 02015 eenerao Power Systems; inc. Ali dilhis reserved. Ali specifications are;sublect te,chsnpe WOW notke. 9ulldn CIM5.9 .R hM In U.SA 07/28/15 Smart Management Modules (SMM) GENERAC® ACCESSORIES Model G006873-0 LISTED DESCRIPTION Generac's Smart Power Management System is designed to optimize the performance of a standby generator. The system can consist of up to 8 IndividualSmartManagementModules (SMM). Unlike other load management systems that depend on another control device, the SMM modules are actually self - aware and operate autonomously. Frequency is the true measure of generator engine performance and does not need to factor in increased ambient temperatures, elevation changes orgeneratorfueltype. The modules monitor the frequency (Hz) of the power being produced by Generac's standby generators and if it falls below a certainthreshold, the module will automatically follow a power management algorithm to ensure that the generator is not overloaded. The modules can be set to a load priority between 1-8 or be set in a lock out only mode for loads that just simply do not need to run in an outage, thereforereducingthenecessarysizeofthegeneratorforamorecosteffectivesolution. SMM SPECIFICATIONS Power Supply Source....................................................- I .......... I.................. Supported Voltages .................................................... Contactor Coll Voltage.......................................................... .... Coil VA Inrush ....................................... .................................................. Coil VA Sealed.......................................................................................................................... Poles......................................................................: Resistive Amps ....................................................... F/L Inductive Amps........................................................................................................................................ ...... Locked Rotor Amps.................................................................................................................................................... UI 50.................... Enclosure Rating............................................................. Wr r 240 VAC (from Line input) 240 VAC 240 VAC 30 6.5 2 50 240@240V Yes NEMA 3R Smart Management Modules (SMM Model G006873-0 Height (iNmm) H1 6.17/156.8 H2 2.36/60 Width (iNmm) W1 7.06/179.4 4.72/120 Depth (INmm) 3.7/94 Weight (IbWlos) 2.06/0.94 Shipping Weight (lbs/kiios) 2.44/1.11 UPC Code 696471068733 SMM Controls (located behind the cover of the module) I LED ON - LOAD CONNECTED A PRIORITY LOCKOUT LED FLASH, S - LOAD SHED a LOAD ON LED FLASH 33 = 30 MIN LOCKOUT LED OFF a NO MODULE POWER s( D7OENEBATOB LED HASH !S = GEN LOAD LOCKOUT 0 O 0 LOCKOUT TEST DISABLED Priority Dial (A) — Sets module priority. Lockout Switch (B) — Prevents load from operating when system is operating under generator power. Test Button (C) — Disables contactor output for a specified time. LED (D) — Provides module status with easy viewing through the external viewing windowlocatedintheupperrightcornerofthemodule. GEAe Dimensions and UPC a Generac Power Systems, Inc. • 845 W29290 HWY. 59, Waukesha, WI 53189 • generac.comGENERAC' _ 02016 Generac Power Systems, Inc. All rights reserved. AII specifications are subject to change without notice. Bulletin OL1500•C 03/10/te REQUIRED INSPECTION SEQUENCE i au ! - dYING pswur Iy11 Iln 1 J C lnns ecfnonIl 1(Descri anon Footer / Sefbacic Stemwall Foundation / Form Board. SulCellSlab /' Mono Slab Pre our Lintel / Tie Beam / FilI / Do Sheathing— Walls- Sheathing-! Roof Roof .)ry In Frame Insulation. Rough In Firewall Screw Pattern Drywall / Sheetrock Lath Inspection Final Solar Final Roof Final Stucco / ,Siding Insulation Final Final Utility', Building - Final Door j I1 Inn Max eetnon IIDesern2non Electric" Underground Footer / Slab Steel Bond Electric Rough T.U.G. Pre -Power Final Electric Final min Mkx— NtitwK t1, f 1c+ry InsCrAp On Plumbing Underground Plumbing Sewer ; Plumbing Tub Set Plumbing Final Final Window Final Screeri.Room Final. Pool Screen Enclosure Mnn j I<n e Il®nn IIDe.s Mobile Home Building Final Mechanical Roug Pre -Demo Mechanical. Final Final Demo j Final Single !Family; Residenceti Final. Building Other ; min Max ICns ec¢n.®n.IlDeser, Gas Underground Gas Rough i Gas Final REVISED: Yune 2014