Loading...
417 Sanford Ave; 18-3874; ROOFSEP 12 2018 Building & Fire Prevention Division PERMIT APPLICATION Application No: 1 s -- 38-1 Documented Construction Value: $ 4,900.00 Job Address: 417 Sanford Ave. S(((JIr'd ,jZ ( Historic District: Yes Noa Parcel ID: 25-19-30-5AG-060A-0060 Residential Commercial Type of Work: New Addition Alteration Repair Demo Change of Use Move Description of Work: Re -Roof 29 gauge galvaloom rib panel n I n Plan Review Contact Person: Saundra Bracken Title: Office Manager Phone: 407-878-3750 Fax: 407-960-2612 Email: BrianSikesRoofing@cfl.rr.com Property Owner Information Name 417 Sanford LCC Phone: 407-448-9471 Street: 417 Sanford LCC Resident of property? : Owner City, State Zip: Sanford, FL 32771 Contractor Information Name Brian Sikes Roofing Phone: 407-878-3750 Street: 1550 S HWY 1792 Fax: 407-960-2612 City, State Zip: Longwood, FL 32750 State License No.: CCC1325977 Architect/Engineer Information Name: Phone: Street: Fax: City, St, Zip: E-mail: Bonding Company: Address: Mortgage Lender: Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: 6' Edition (2017) Florida Building Code Revised: January 1, 2018 Permit Application NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal. The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value, credit will be applied to your permit fees when the permit is issued. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. gnature of Owner/Agent Date l Print Oy&Qf/Agent's Name 4P ft,4V Notary Public State of FloridaStevenCampbell 7 My Commission FF 990959 OF ao Expires 05/10/2020 Ito /I Signature of Contractor/Agent Date JW—c Print S/tJC Name Notary Public State of Florida Steven Campbell y My Commission FF 990959 aa Expires05/10/2020 Owner/Agent is personally Known to Me or Contractor/Agent is j Personally Known to Me or Produced ID Type of ID Produced ID 11 Type of ID BELOW IS FOR OFFICE USE ONLY Permits Required: Building Electrical Mechanical Plumbing[] Gas[] Roof Construction Type: Total Sq Ft of Bldg: Occupancy Use: Min. Occupancy Load: New Construction: Electric - # of Amps. Fire Sprinkler Permit: Yes No # of Heads APPROVALS: ZONING: ENGINEERING: COMMENTS: UTILITIES: FIRE: Flood Zone: of Stories: Plumbing - # of Fixtures Fire Alarm Permit: Yes No WASTE WATER: BUILDING: Revised: January 1, 2018 Permit Application r rian Sikes nG Inc. 1550 S. Hwy 17 92 Ph: (407) 960-2611 Longwood, FL 32750 Fax: (407) 960-2612 NAME/ADDRESS Land Mark Building & Construction 417 Sanford Ave. Sanford, FL 32771 Fax#407-323-5571 ATTN: *JIM* PROPOSAL DATE PROPOSAL; 6/11/2018 8968 Contractor submits this proposal for work on the property herein described. Upon acceptance, Contractor agrees to furnish labor and materials necessary to improve the above premises in a good, workmanlike and substantial manner according to the terms, specifications, prices and plans (if any). Start and Completion: The approximate start date of and approximate completion date of are subject to permissible delays as per provision (5) on the reverse side. Submitted by X Approved and Accepted (Contractor) Date DESCRIPTION OF WORK AND MATERIALS QTY RATE TOTAL;I Remove rib panels from Ix4 batten strips, and batten strips (4sq.) 4,900.00 4,900.00 Install 4ply 1/2in. plywood over trusses. Install new 2x6 subfascia and 1 x6 fascia board over plywood. Install high temp peal and stick. Install new galvanized rib panels over high temp peal and stick. Flash and counter flash head wall and around stove vent. Ground will be swept with a magnet at the end of each working day. Clean entire work area and haul away all debris. 7 YEAR LEAK WARRANTY (LABOR AND MATERIALS) Price includes labor, materials, taxes and all permitting fees. Contractor shall provide all releases of lien from contractor, subcontractors, and material suppliers. TOTAL 4,900.00 ACCEPTANCE OF PROPOSAL This Proposal is approved and accepted. There are no oral agreements. The written terms, specifications, provisions, prices and plans (if any) are the entire agreement. Changes will be X made by written change order only. Credit cards may be subject to a 3% convenience charge. pproved and Accepted(Owner) Date You, the Buyer, may cancel this transaction at any time prior to midnight of the third business day after the date of this transaction. See Owner's Right to Cancel on the reverse side for details. Grant Maloy, Clerk Of The Circuit Court & Comptroller Seminole County, FL Inst #2018104107 Book:9208 Page:1105; (1 PAGES) RCD: 9/12/2018 2:51:36 PM REC FEE $10.00 THIS INSTRUMENT PREPARED BY: Name: Saundra Bracken Address: 1550 S Hwy 17 92 Longwood, FI 32750 NOTICE OF COMMENCEMENT Permit Number. Parcel ID Number: 25-19-30-5AG-060A-0060 The undersigned hereby gives notice that improvement will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement. 1. DESCRIPTION OF PROPERTY: (Legal description of the property and street address if available) 417 S SANFORD AVE SANFORD FL 32771- LOT 6 BLK 6 TR A TOWN OF SANFORD PB 1 PG 56 & LOT 3 BLK 6 2. GENERAL DESCRIPTION OF IMPROVEMENT: Re -Roof 29 gauge gaivaloom rib panel roof 3. OWNER INFORMATION OR LESSEE INFORMATION IF THE LESSEE CONTRACTED FOR THE IMPROVEMENT: Name and address: 417 SANFORD LLC - 559 E HIGHLAND ST ALTAMONTE SPRINGS, FL 32701 Interest in property: Owner Fee Simple Title Holder (if other than owner listed above) N 4. CONTRACTOR: Name: Brian Sikes Address: 1550 S Hwy 17 92 Longwood FI 32750 5. SURETY (If applicable, a copy of the payment bond is attached): Name: Phone Number. 407-878-3750 Address: Amount of Bond: 6. LENDER: N Address: Phone Number: 7. Persons within the State of Florida Designated by Owner upon whom notice or other documents maybe served as provided by Section 713.13(1)(a)7., Florida Statutes. Name: Phone Number: 8. In addition, Owner designates to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b), Florida Statutes. Phone number: 9. Expiration Date of Notice of Commencement (The expiration is 1 year from date of recording unless a different date is spercified) WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. signature of Owner a L s , or Owners or Lessee's (Print Name and Provide Signatories TitlelOffice) Authorized Otfrcer/Director/Partner/Manager) c State of YL County of 7;&I/LCG OL& The foregoing instrument was acknowledged before me this it day of f t r !/ if f2 0 by --N +(yV &- / uL/y J Who is personally known to me O OR Name of pelon_qgdng stateent hh who has produced identificationemofidentificationproduced: LpATPQ,* Notary Public Stets OIFbriraStevenCampbell My Commission FF 9909M9Notary signature Expires 05/10/2020- 4 y< .yam Lip N S rfu—nud DUllu111g %_Uut; 11111111E 31r • ' rags 1 L)1 fflt SIT h yi i Y• . 5, ^l rS..Fikss'w. H H.s'13..f'' Ssx-""-_.ter_.-+' ..... , . r , . • , . - - , . ,. , BCIS Home Log In User Registration Hot Topics .' Submit Surcharge stats & Facts Publications FBC Staff''' BCIS Site Map Links ! Search e j Product Approvaldbrk9USER: Public User Product Approval Menu > Product or Application Search > Application List > Application Detail r FL # FL17401-R4 PERMITApplicationTypeRevision Code Version 2017 Application Status Approved Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Mid -States Asphalt & Cant Strip, Inc. 1637 51st Avenue Tuscaloosa, AL 35401 205) 345-6634 moises@msaroof.com Moises Rached moises@msaroof.com Eric Bailey 1637 51st Avenue Tuscaloosa, AL 35401 205) 345-6634 erlc@msaroof.com Eric Bailey 1637 51st Avenue Tuscaloosa, AL 35401 205) 345-6634 eric@msaroof.com Roofing Underlayments Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed Zachary R. Priest the Evaluation Report Florida License PE-74021 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 12/31/2019 Validated By Locke Bowden Validation Checklist - Hardcopy Received Certificate of Independence FL17401 R4 COI MSA17001 FBC 2017 Evaluation Report OUIK-Stick FINAL.Pddf Referenced Standard and Year (of Standard) Standard ASTM D1970 TAS 103 UL 1897 Equivalence of Product Standards Certified By Year 2015 1995 2012 https://www.floridabuilding.org/pr/pr_app_dtl. aspx?param=wGEV XQwtDgtCUGgvj Qiz6G... 2/5/2018 rlurlua I)Uliulllg wue vrnlne Sections from the Code rage z of z Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Summary of Products Method 1 Option D 08/12/2017 10/11/2017 08/16/2017 10/12/2017 FL # Model, Number or Name Description 17401.1 QUIK-Stick IW, QUIK-Stick IWS, Self -Adhered Underlayments QUIK=Stick HT, QUIK-Stick HT -Pro, QUIK-Stick FS Limits of Use Installation Instructions Approved for use in HVHZ: No FL17401 R4 II MSA17001 FBC 2017 Evaluation Report OUIK-Stick FINAL.pdfApprovedforuseoutsideHVHZ: Yes Impact Resistant: No Verified By: Zachary R. Priest PE-74021 Design Pressure: +0/-52.5 Created by Independent Third Party: Yes Other: Refer to Evaluation Report for Limitations of Use. Evaluation Reports Wind uplift applicable to QUIK-Stick HT only. FL17401 R4 AE MSA17001 FBC 2017 Evaluation Report QUIK-Stick FINAL.Pdf Created by Independent Third Party: Yes Back Next Contact Us :: 2601 Blair Stone Road. Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida Is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. -Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address If they have one. The emalls provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: eC M Credit Card Safe https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtCUGgvj Qiz6G... 2/5/2018 Certificate ofAuthorizationion bur Drive 9824 CREEK17520 Edinburgh Drive Tampa, FL 33647 TECHNICAL SERVICES, LLC (813) 480-3421 EVALUATION REPORT FLORIDA BUILDING CODE, 6T" EDITION (2017) Manufacturer: MID -STATES ASPHALT AND CANT STRIP, INC. Issued October 11, 2017 1637 5151 Street Tuscaloosa, AL 35401 800) 489-2391 www. msaroof.com Manufacturing Location: Tuscaloosa, AL Quality Assurance: UL LLC (QUA9625) SCOPE Category: Roofing Subcategory: Underlayments Code Sections: 1504.3.1, 1507.1.1 Properties: Physical properties PRODUCT DESCRIPTION AND LIMITS OF USE QUIK- Stick Ice & Water QUIK-Stick Ice & Water Granular is an ASTM D 1970 self-adhesive underlayment Granular constructed from SIBS modified asphalt, a fiberglass mat reinforcement and surfaced with granules. The product is supplied in 2-sq. rolls with nominal dimensions of 3-ft x 66. 8-ft and has a nominal thickness of 50 mils. QUIK- Stick Ice & Water Granular is permitted to be used as prescribed in FBC Section 1507. 1.1 for mechanically attached roofing coverings. Exposure on the roof deck shall be limited to a maximum 30 days. QUIK- Stick Ice & Water QUIK-Stick Ice & Water Sand is an ASTM D 1970 self-adhesive underlayment Sand constructed from SBS modified asphalt with a fiberglass mat reinforcement and surfaced with sand. The product is supplied in 2-sq. rolls with nominal dimensions of 3-ft x 66.8-ft and has a nominal thickness of 50 mils. QUIK- Stick Ice & Water Sand is permitted to be used as prescribed in FBC Section 1507. 1.1 for mechanically attached roofing coverings. Exposure on the roof deck shall be limited to a maximum 30 days. QUIK- Stick HT QUIK-Stick HT is an ASTM D 1970 self-adhesive underlayment constructed from SIBS High Temperature) modified asphalt with a fiberglass mat reinforcement and poly -fabric surface. The product is supplied in 2-sq. rolls with nominal dimensions of 3-ft x 66.8-ft or 3-ft 3-in x 61- ft and has a nominal thickness of 60 mils. QUIK- Stick HT is to be used as prescribed in FBC Section 1507.1.1. QUIK-Stick HT is permitted to be used with adhered clay or concrete tile roofing using either ICP Adhesives Polyset AH-160 (ICP Adhesives and Sealants, Inc.). Exposure on the roof deck shall be limited to a maximum 90 days. The maximum roof slope shall be 6:12 when used with clay or concrete tile installations without battens. Tile shall be stored on battens for roof slopes greater than 6:12. Tiles shall not be stacked greater 10 tiles per stack. . MSA17001 FL17401-R4 Page 1 of 4 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. MID -STATES ASPHALT AND CANT STRIP, INC n7 E CREEK Self -Adhering Underlayments TECHNICAL SERVICES, LLC QUIK-Stick HT Pro QUIK-Stick HT Pro is an ASTM D 1970 self-adhesive underlayment constructed from High Temperature) SBS modified asphalt with a fiberglass mat reinforcement and poly -fabric surface. The product is supplied in 2-sq. rolls with nominal dimensions of 3-ft x 66.8-ft and has a nominal thickness of 60 mils. QUIK-Stick HT Pro is permitted to be used as prescribed in FBC Section 1507.1.1 for mechanically attached roofing coverings. Exposure on the roof deck shall be limited to a maximum 30 days. QUIK-Stick FS QUIK-Stick FS is an ASTM D 1970 self-adhesive underlayment constructed from SBS Film Surface) modified asphalt with a fiberglass mat reinforcement and textured film surface. The product is supplied in 2-sq. rolls with nominal dimensions of 3-ft x 66.8-ft and has a nominal thickness of 45 mils. QUIK-Stick FS is permitted to be used as prescribed in FBC Section 1507.1.1 for mechanically attached roofing coverings. Exposure on the roof deck shall be limited to a maximum 30 days. PRODUCT APPLICATION Min. Roof Slope: 2:12 or in accordance in with the FBC Application: All underlayments shall be installed in accordance with the FBC. Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck shall be checked for protrusion and corrected prior to underlayment application. Prior to beginning installation, the underlayment shall be unrolled and allowed to relax for a minimum of 3-5 minutes. The underlayment shall be installed with the release backer removed and pressed firmly into place to ensure complete contact with the deck. The underlayment shall be installed With the roll length parallel to the eave, starting at the eave, and with minimum 3" side laps and minimum 6" end laps staggered min. 6-ft.from preceding course. It is permissible to back nail the underlayment 12-inches on -center as needed (nails shall be installed perpendicular to deck with the nail heads flush to the top surface of the underlayment). Min. Application 40°F; Contact the manufacturer when installing at temperatures below the minimum Temperature: application temperature. WIND RESISTANCE The Maximum Design Pressures shown below were calculated using a 2:1 margin of safety per FBC Section 1504.9. Underlayment System No.1 — QUIK-Stick HT only Roof Deck: Min. 15/32-inch CDX plywood attached to wood supports spaced a maximum 24" o.c. Underlayment: QUIK-Stick HT shall be fully adhered to the optionally primed plywood deck. Maximum Design -52.5 psf Pressure: MSA17001 FL17401-R4 Page 2 of 4 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK PY w TECHNICAL SERVICES, LLC GENERAL LIMITATIONS MID -STATES ASPHALT AND CANT STRIP, INC Self -Adhering Underlayments 1) This evaluation report is not use in the HVHZ. 2) Fire Classification is not within the scope of this evaluation. 3) Installation of the evaluated product shall comply with this report, the FBC, and the manufacturer's published application instructions. Where discrepancies exist between these sources, the more restrictive and FBC compliant installation detail shall prevail. 4) The roof deck shall be constructed of closely fitted plywood sheathing for new or existing construction. 5) The space under the deck area shall be properly ventilated in accordance with the FBC requirements. 6) All side lap seams shall be installed to shed water from the deck. 7) The underlayment may be used as described in other current FBC product approval documents. 8) Design wind load pressures shall be determined for components and cladding in accordance with FBC 1609. 9) The roof deck shall be designed by others in accordance with FBC requirements to resist the design wind load pressures for components and cladding. 10) Maximum Design Pressures for a given underlayment shall meet or exceed the design wind loads determined for the roof assembly. 11) All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61 G20-3. REFERENCES Eafty Report No. Standard Year PRI Construction Materials Technologies (TST5878) BWR-514-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies (TST5878) BWR-522-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies (TST5878) BWR-533-02-01 TAS 103 1995 PRI Construction Materials Technologies (TST5878) BWR-534-02-01 ASTM D 1970 2015a ASTM D 4798 2011(2016) PRI Construction Materials Technologies (TST5878) BWR-543-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies (TST5878) WRMI-011-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies (TST6049) MSA-007-02-01 UL 1897 2012 PRI Construction Materials Technologies (TST6049) MSA-026-02-01 ASTM D 1970 2015a MSA17001 FL17401-R4 Page 3 of 4 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC COMPLIANCE STATEMENT MID -STATES ASPHALT AND CANT STRIP, INC Self -Adhering Underlayments The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building Code, 6t' Edition (2017) as evidenced in the referenced documents submitted by the named manufacturer. 01111111111 No 74021 tit STATE OF :IJJOR s 10 N A11 E CERTIFICATION OF INDEPENDENCE 2017.10.11 04'00' Zachary R. Priest, P.E. Florida Registration No. 74021 Organization No. ANE9641 CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. END OF REPORT MSA17001 FL17401-R4 Page 4 of 4 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. City of Sanford Building and Fire Prevention Product Approval Specification Form Permit # Y p 7 9 Project Location Address 417 Sanford Ave. Sanford, FL 32771 i13LkNq rQ- As required by Florida Statute 553.842 and Florida Administrative Code 9N-3, please provide the information and product approval number(s) on the building components listed below if they are to be utilized on the construction project for which you are applying for a building permit. We recommend that you contact your local product supplier should you not know the product approval number for any of the applicable listed products. Be aware that windows, skylights, and exterior doors must be tested in accordance with the Florida Building Code, Section 1714.5. More information about Statewide Product Approval can be obtained at www.floridabuilding.org. The following information must be available on the jobsite for inspections: 1. This entire product approval form 2. A copy of the manufacturer's installation details and requirements for each product. Category/Subcategory Manufacturer Product Description Florida Approval # include decimal) 1. Exterior Doors Swinging Sliding Sectional Roll U Automatic Other 2. Windows Single Hun Horizontal Slider Casement Double Hun Fixed Awning Pass Through Projected Mullions Wind Breaker Dual Action Other June 2014 r Category/Subcategory Manufacturer Product Description Florida Approval # including decimal 3. Panel Walls Siding Soffits Storefronts Curtain Walls Wall Louver Glass block Membrane Greenhouse E.P.S Composite Panels Other 4. Roofing Products Asphalt Shingles Underla ments Mid -States QUIK-Stick High Temp FL17401.1 Roofing Fasteners Grip -Rite Hex -head Neo-Prene Screws F1667-95 Nonstructural Metal Roofing Millennium Metals Rib Panel FL5211.2 R7 Wood Shakes and Shingles Roofing tiles Roofing Insulation Waterproofing Built up roofing System Modified Bitumen Single Ply Roof Systems Roofing slate Cements/ Adhesives / Coating Liquid Applied Roofing Systems Roof Tile adhesive Spray Applied Polyurethane Roofing E.P.S. Roof Panels Roof Vents Other June 2014 Category / Subcategory Manufacturer Product Description Florida Approval # include decimal) 5. Shutters Accordion Bahama Colonial Roll u Equipment Other 6. Skylights Skylights Other 7. Structural Components Wood Connectors / Anchors Truss Plates Engineered Lumber Railing Coolers/Freezers Concrete Admixtures Precast Lintels Insulation Forms Plastics Deck / Roof Wall Prefab Sheds Other 8. New Exterior Envelope Products Applicant's Signature - ---- Applicant's Name gv ijw, s;rzs Please Print) June 2014 9/11/2018 Florida Building Code Online gg A; BCIS Home Log In User Registration Hot Topics j Submit Surcharge j Stats & Facts Publications Contact Us BCIS Site Map Links Search dlFlorida p r s Product Approval t,' r 0USER: Public User PERMIT # c rAt:xt isx: t- Product pproval Menu > Product or Apollcation Search > epollcat(on Llst > Application Detail FL # FL5211-R7 Application Type Revision Code Version 2017 Application Status Approved Comments Archived Product Manufacturer MILLENNIUM METALS INC. Address/Phone/Email 10200 Eastport Road Jacksonville, FL 32218 904)358-8366 tonyac@mmi2000.net Authorized Signature James Buckner jimmy@cbuckinc.net Technical Representative Tonya Steele Address/Phone/Email 10200 Eastport Road Jacksonville, FL 32218 904)358-8366 tonyac@mmi2000.net Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Metal Roofing Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the James L. Buckner Evaluation Report Florida License PE-31242 Quality Assurance Entity Keystone Certifications, Inc. Quality Assurance Contract Expiration Date 09/22/2026 M. - U icfi;--PE -------- ---- --- --- Validated By Steven -- - -- — Validation Checklist - Hardcopy Received Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By FL5211 R7 COI COI CertOf Indeo James BUCkner,P.E. sc.PDF Standard Year TAS 125 2003 UL1897 2012 UL 580 2006 Florida Licensed Professional Engineer or Architect FL5211 R7 Eauiv 5211 Test Standard Eauiv.p_df Sections from the Code https://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgvWKGCdrv%2fKmeCAr4mW8KzZEApSgUEivtl%3d 1/2 9/11/2018 Florida Building Code Online Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Summary of Products Method 1 Option D 10/20/2017 10/27/2017 10/29/2017 12/12/2017 FL # Model, Number or Name Description 5211.1 1- "5-V Crimp" and "Millennium-V" Lapped Roof Panel, 26 Gauge (Minimum Thickness) Steel, 24" Wide Panel Attached to Wood Deck Limits of Use Installation Instructions Approved for use in HVHZ: No FL5211 R7 II 17-196-1-5V WoodDeck-ER.pdf Approved for use outside HVHZ: Yes Verified By: James L. Buckner, P.E. @ C-Buck, Inc. P.E. Impact Resistant: No 31242 Design Pressure: +See/ -Report Created by Independent Third Party: Yes Other, Refer to Evaluation Report for Limitations and Evaluation Reports Conditions of Use. Refer to manufacturer's installation FL5211 R7 AE 17-196-1-5V WoodDeck-ER.pdf instructions as a supplemental guide for attachment. Created by Independent Third Party: Yes 5211.2 2- "Rib Panel" Lapped Roof Panel, 29 Gauge (Minimum Thickness) Steel, 36" Wide Panel Attached to Wood Deck Limits of Use Installation Instructions Approved for use in HVHZ: No FL5211 R7 II 17-196-2-Rib WoodDeck-ER.pdf Approved for use outside HVHZ: Yes Verified By: James L. Buckner, P.E. @ C-Buck, Inc. P.E. Impact Resistant: No 31242 Design Pressure: +See/ -Report Created by Independent Third Party: Yes Other: Refer to Evaluation Report for Limitations and Evaluation Reports Conditions of Use. Refer to manufacturer's installation FL5211 R7 AE 17-196-2-Rib WoodDeck-ER.pdf instructions as a supplemental guide for attachment. Created by Independent Third Party: Yes 5211.3 3- "M-Seam" Snap Lock Roof Panel, 26 Gauge (Minimum Thickness) Steel, 16" Wide Panel Attached to Wood Deck Limits of Use Installation Instructions Approved for use in HVHZ: No FL5211 R7 II 17-196-3-MSeam WoodDeck-ER.pff Verified By: James L. Buckner, P.E. @ CBUCK, Inc. RE/ Approved for use outside HVHZ: Yes Impact Resistant: No 31242 Design Pressure: +See/ -Report Created by Independent Third Party: Yes Other: Refer to Evaluation Report for Limitations and Evaluation Reports Conditions of Use. Refer to manufacturer's installation FL5211 R7 AE 17-196-3-MSeam WoodDeck-ER.pdf Created by Independent Third Party: Yesinstructionsasasupplementalguideforattachment. BacF Next Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyljght 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. 'Pursuant to Section 455.275(1), Florida'Statutes,-effective October* 1, 2012,-licensees-licensed-underChapter 455-F.S.-must-provide the Department with -an email -address If they -have one: The-emails-- provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: RR N Credit Card Safe https:// www.floridabuilding.org/prlpr app_dtl.aspx?param=wGEVXQwtDgvWKGCdrv%2fKmeCAr4mW8KzZEApSgUEivU*/a3d 2/2 SpeciaN Structural Englnel=rinq Evaluation Report Rib Panel" Metal Roof Assembly Manufacturer: CBUCK, Inc. Certificate of Authorization #8064 Millennium Metals, Inc. 10200 Eastport Road Jacksonville, FL 32218 877) 358-7663 for Florida Product Approval FL 5211.2 R7 Florida Building Code 6th Edition (2017) Per Rule 61G20-3 Method: 1- D Category: Roofing Sub - Category: Metal Roofing Product: "Rib Panel' Material: Steel Panel Thickness: 29 gauge, Minimum Facsimile of digital copy signed by Panel Width: 36" James L. Buckner, P.E. Support: Wood Deck Electronically signed and sealed documents shall comply with the provisions of FAC Rule 61G15-23. 111 liiirrriiiSLBUC p -_ y; --------- -------------------- Pre ared-b------------ CEN sF •• ----_---- James L. Buckner, P.E., SECB No31242 Florida Professional Engineer # 31242 W Florida Evaluation ANE ID: 1916 STATE OF 4U Report No. 17-196-Rib-S9W-ER•F ORIDP.• p 0 N Revises 15-104-Rib-SW-ER) AX- Date: 10 / 16 / 17 f { Contents: Evaluation Report Pages 1— 9 2017.10.19 20:13:36-04'00' CBUCK, Inc. — Palm Beach County, Florida Phone: (561) 491-9927 • Email: cbuck@cbuckinc.net • Website: www.cbuckinc.net Main Office: 1374 Community Drive, Jupiter, Florida 33458 i__ Zrwwl I Specialty Structural Engineering Manufacturer: Millennium Metals, Inc. Product Name: "Rib Panel" FL #: FL 5211.2-117 Date: 10 / 16 / 17 Report No.: 17-196-Rib-SM-ER Page 2 of 9 CBUCK, Inc. Certificate of Authorization #8064 Product Category: Roofing Product Sub -Category Metal Roofing Compliance Method: State Product Approval Rule 61G20-3.005 (1) (d) Product/System Rib Panel" Description: 29 gauge (Minimum Thickness) Steel roof panel mechanically attached to Plywood Deck with screws. Product Assembly as Refer to Page 4 of this report for product assembly components/materials & standards: Evaluated: 1. Roof Panel 2. Fasteners 3. Underlayment 4. Insulation (Optional) 5. Barrier Board (Optional) Support: Type: Wood Deck Design of support and its attachment to support framing is outside the scope of this evaluation.) Description: 15/32 (min.) or 19/32" (min.) or greater plywood, or Wood plank (min. specific gravity of 0.42) inimum-slope _shall -be _in_compliance with_FBC Chapter 15_Section_1507.4.2,_applicable__ code sections and in accordance with manufacturer's recommendations. Performance: Wind Uplift Resistance: Design Uplift Pressure: Refer to Table "A" Refer to "Table A" attachment details herein) FL M FL 5211.2-117 Date: 10 / 16 / 17 Report No.: 17-196-Rib-S9w-ER Page 3 of 9 Specialty Structural Engineering CBUCK, Inc. Certificate of Authorization #8064 Performance Standards: The product described herein has demonstrated compliance with: UL580-06 - Test for Uplift Resistance of Roof Assemblies UL 1897-12 - Uplift test for roof covering systems Standards Equivalency: • The UL 580-94 standard version used to test the evaluated product assembly is equivalent to UL580-06 standard version adopted by the Florida Building Code 6th Edition (2017). The UL 1897-98 standard version used to test the evaluated product assembly is equivalent to UL1897-12 standard version adopted by the Florida Building Code 6th Edition (2017). Code Compliance: The product described herein has demonstrated compliance with Florida Building Code 6th Edition (2017), Section 1504.3.2. Evaluation Report Scope: This product evaluation is limited to compliance with the structural requirements of the Florida Building Code, as related to the scope section to Florida Product Approval Rule 61G20-3.001. Limitations and • Scope of "Limitations and Conditions of Use" for this evaluation: Conditions of Use: This evaluation report for "Optional Statewide Approval' contains technical documentation, specifications and installation method(s) which include "Limitations and Conditions of Use" throughout the report in accordance with Rule 61G20-3.005. Per Rule 61G20-3.004, the Florida Building Commission is the authority to approve products under "Optional Statewide Approval'. Option for application outside "Limitations and Conditions of Use" Rule 61G20-3.005(l)(e) allows engineering analysis for "project specific approval by the local authorities having jurisdiction in accordance with the alternate methods and materials authorized in the Code". Any modification of the product as evaluated in this report and approved by the Florida Building Commission is outside the scope of this evaluation and will be the responsibility of others. This report is a building code product evaluation per FLPE rule (FAC) 61G15-36 to comply with Florida product approval rule (FAC) 61G20-3. This evaluation report is part of the Florida Building Commission approval for the listed code related criteria. This report by James Buckner, P.E. and CBUCK Engineering is not a design certification of codecompliance construction submittal documentation, per FBC section 107,-for-any individual structure, site specific or permit design. All metal components and fasteners shall be corrosion resistant in accordance with applicable sections of FBC, including but limited to Sections 1504.3.2, 1506.6 and 1507.4.4. Design of support system is outside the scope of this report. Fire Classification is outside the scope of Rule 61G20-3, and is therefore not included in this evaluation. This evaluation report does not evaluate the use of this product for use in the High Velocity Hurricane Zone code section. (Dade & Broward Counties) Quality Assurance: The manufacturer has demonstrated compliance of roof panel products in accordance with the Florida Building Code and Rule 61G20-3.005 (3) for manufacturing under a quality assurance program audited by an approved quality assurance entity through Keystone Certifications, Inc. (FBC Organization M QUA 1824). FL #: FL 5211.2-117 Date: 10 / 16 / 17 Report No.: 17-196-Rib-M-ER Page 4 of 9 Specialty Structural Engineering CBUCK, Inc. Certificate of Authorization #8064 Components/Materials Roof Panel: by Manufacturer): Product Identification: Rib Panel Material: Steel Thickness: 29 gauge (min.) Panel Width: 36" (max.) Coverage Rib Height: 3/4" Yield Strength: 40 ksi min. Corrosion Resistance: In compliance with FBC Section 1507.4.3: ASTM A792 coated, or ASTM A653 G90 galvanized steel Fastener: Type: Hex -Head Wood Screw with WSW Size: #10 (x length to meet min. penetration through deck) Penetration Through: 3/16" min. through wood deck Corrosion Resistance: Per FBC Section 1506.6 and 1507.4.4 Standard: Per ANSI/ASME B18.6.4 Components/Materials Underlayment: by Others): Material and application shall be in compliance with FBC Section 1507.1.1 and in accordance with applicable code sections and manufacturer's recommendations. Insulation (Optional): Type: Rigid Insulation Board Thickness: 3" (max.) Properties: Density: 2.25 pcf (Ibs/ft3) min. Insulation Notes: Rigid Insulation shall meet minimum density OR compressive strength. Insulation shall comply with FBC Section 1508. When insulation is incorporated, fastener length shall conform to penetrate thru bottom of support a minimum of 3/16". Barrier (Optional): Barrier Board: Approved Barrier, up to 1/2" thick FL #: FL 5211.2-117 Date: 10 / 16 / 17 Report No.: 17-196-Rib-59W-ER Page 5 of 9 Specialty Structural Engineering CBUCK, Inc. Certificate of Authorization #8064 Installation: Installation Method: Refer to drawings on Pages 6-8 of this report.) Fastener spacing: Refer to Table "A" Below along the length of the panel) Row Spacing: Refer to Table "A" Below along the row, across the panel profile) Rib Interlock: Lapped Minimum fastener penetration thru bottom of support, 3/16". For panel construction at the end of panels, refer to manufacturer's instructions and any site specific design. TABLE "A„ ALLOWABLE LOADS Deck Thickness Fastener Spacing Row Spacing Refer to Drawings Design Pressure PSF) METHOD 1 15/32" 9" 24" A 47.5 METHOD 2 15/32" 9" 12" A 95 METHOD 3 15/32" 5",4",5",4",... Pattern 16" B 113.75 METHOD 4 19/32" 9" 16" A 71 METHOD 5 19/32" 5",4",5",4...... Pattern 16" B 144.25 Allowable design pressure for allowable stress design (ASD) with a margin of safety of 2 to 1. Install the "Millennium Rib" roof panel assembly in compliance with the installation method listed in this report and applicable code sections of FBC 6th Edition (2017). The installation method described herein is in accordance with the scope of this evaluation report. Refer to manufacturer's installation instructions as a supplemental guide for attachment. Referenced Data: 1. UL580-94 & UL 1897-98 Uplift Test By Hurricane Test Laboratory, LLC (FBC Organization #TST ID: 1527) Report #: 0232-0321-03, Report Date: 8/27/03, Specimens #1-2 Report.#:A232-0510-03,_Report_Date:_8/27/03,.Specimen#2_____ 2. UL580-94 & UL 1897-98 Uplift Test By Hurricane Test Laboratory, LLC (FBC Organization #TST ID: 1527) Report #: 0232-0911-05, Report Date: 9/27/04, Specimen #1 3. Engineering Analysis By CBUCK Engineering 4. Quality Assurance By Keystone Certifications, Inc. (QUA ID: 1824) Millennium Metals Licensee # 423 5. Equivalency of Test Standard Certification By James L. Buckner, P.E. @ CBUCK Engineering FBC Organization # ANE 1916) 6. Certification of Independence FL #: FL 5211.2-R7 Date: 10 / 16 / 17 Report No.: 17-196-Rib-M-ER Page 6 of 9 Specialty Structural Engineering CBUCK, Inc. Certificate of Authorization #8064 By James L. Buckner, P.E. @ CBUCK Engineering FBC Organization # ANE 1916) Installation Method Millennium Metals Rib Panel" Roof Panel Attached to Wood Deck 91 Profile Drawings 95 Typical Panel Profile View (Not To Scale) T 3141 TABLE "A" ALLOWABLE LOADS Deck--- Thickness Fastener—— Spacing Row-------Refer-to--- Spacing Drawings Design-Pressure-- PSF) METHOD 1 15/32" 9" 24" A 47.5 METHOD 2 15/32" 9" 12" A 95 METHOD 3 15/32" 5",4",5",4",... Pattern 16" B 113.75 METHOD 4 19/32" 9" 16" A 71 METHOD 5 19/32" 5",4",5",4",... Pattern 16" B 144.25 Allowable design pressure for allowable stress design (ASD) with a margin of safety of 2 to 1. FL #: FL 5211.2-R7 Date: 10 / 16 / 17 Report No.: 17-196-Rib-SM-ER Page 7 of 9 SpPclalty Structural Engineering CBUCK, Inc. Certificate of Authorization #8054 Installation Method Millennium Metals Rib Panel" Roof Panel Attached to Wood Deck 9" 1 9" 1 g' 1 g' Fastener Spacng Across Panel Wdth 10 Hex Head Mod Screwwith V\SVV 311 Fmin penetration thru deck Spaoed T as across the panel Detail A - Typical Assembly Profile View (Not To Scale) Specialty Structural Engineerinq r M:T2% FL #: FL 5211.2-117 Date: 10 / 16 / 17 Report No.: 17-196-Rib-S9W-ER Page 8 of 9 CBUCK, Inc. Certificate of Authorization #8054 Refer to Table "A" for Mnimimn- idoiess Detail A - Typical Assembly Isometric View (Not To Scale) Installation Method Millennium Metals Rib Panel" Roof Panel Attached to Wood Deck 5' 14' 5' 41 5' T— Fastener Spadng Across Panel Wdth 10 Hex -Head Wood Screvvwith VVSW 3116' rrin. penetration t m deck Spaced in a 5', 4', 5', 4', F, 4', S', 4' Pattern FL #: FL 5211.2-R7 Date: 10 / 16 / 17 Report No.: 17-196-Rib-S9W-ER Page 9 of 9 Specialty Structural Engineering CBUCK, Inc. Certificate of Authorization #8054 Detail B - Typical Assembly Profile View (Not To Scale) Pcv-4onor Detail B - Typical Assembly Isometric View (Not To Scale) INSPECTION SEQUENCE BP# 18-3874 ADDRESS: 417 Sanford Avenue BUILDING PERMIT Min Max Ins ection Description Footer / Setback Stemwall Slab / Mono Slab Lintel / Tie Beam / Fill / Down Cell Sheathing — Walls Sheathing — Roof 10 Roof Dry In Frame Insulation Rough Firewall Screw Pattern Drywall / Sheetrock Lath Inspection Building Ceiling Air Barrier Insulation Roof (Com'1) Building Ceiling Grid 1000 Final Roof Final Stucco / Siding Final Insulation Final Firewall Final Door Final Window Final Utility Building Final Screen Structure Final Pool Screen Enclosure Pre -Demo Final Demo Final Single Family Residence Final Commercial — Final Commercial — Addition / Alteration Final Commercial — Change of Use Final Building (Other) ELECTRICAL PERIVIIT Min Max Inspection Description Electric Underground Footer / Slab Steel Bond Electric Ceiling Rough Electric Wall Rough Electric Rough Pre -Power Final Temporary Pole Electric Final PLUMBINGPERI Ti Min Max Ins ection Description Rough Plumb Plumbing Underground Plumbing 2"a Rough Plumbing Tubset Plumbing Sewer Plumbing Grease Trap Rough Plumbing Steam / Chill Water Rough Plumbing Final ME& NIltM PERMIT g "17:411,111 - ':at Min Max Inspection Description Mechanical Rough Mechanical Fire Damper Framing Mechanical Ceiling Rough Mechanical Fire Damper Annular Space Mechanical Insulation Wrap Mechanical Fire Damper Angle Light / Water Test Ck Welds Mechanical Grease Duct Wrap Mechanical Final REVISED: June 2014