Loading...
2437 Marshall Ave 05-4151 SFRPERMIT ADDREQ CONTRACTOR ADDRESS METRO DEVELOPMENT GROUP INC 129 ROBIN RD ALTAMONTE SPRINGS, FL 32701 PHONE NUME 407 599-4711 CBC1251965 PROPERTY 04, ADDRESS John B Muroski 732 Keaton Pkwy. Ocoee, FI 32761 PHONE NUMBER 407-654-1594 ELECTRICAL CONTRACTOR MECHANICAL CONTRACTOR PLUMBING CONTRACTOR MISCELLANEOUS CONTRACTOR PERMIT NUMBER MISCELLANEOUS CONTRACTOR PERMIT NUMBER FEE FEE %ONAJ 1 14Nd" SUBDIVISION a Qflq'*. %A.>4* % Ok • 'm PERMIT # os �' DATE COXXI qk, PERMIT DESCRIPTION ('N eAO S I F PERMIT VALUATION SQUARE FOOTAGE 10 City of Sanford Certificate of Occupancy This is to certify that the building located at 2437 Marshall Ave for which permit number 05-4151 has heretofore been issued on August 28, 2005 and has been completed according to plans and specifications filed in the office of the Building Official prior to the issuance of said building permit, to wit as New Single Family Residence subdivision regulations ordinances of the City of Sanford with the provisions of these regulations. Staff Approval Building: R Addison Engineering & Planning: G. Hyatt Public Works: M Watson Utilities: Date 08/30/06 08/31 /06 08/30/06 R Blake 08/30/06 Fire Department: Conditions (if blank, no condition$ apply) John B Muroski Yv� .� .� _ 09/12/06 Property Owner Building Official Date �__--- — —--- __------ --— _— ---_. -- BUILDING DEPARTMENT - Re: 2437 Marshall Avenue 1 From: RUBEN HYATT To: BUILDING DEPARTMENT Date: 8/31/2006 12:48 pm Subject: Re: 2437 Marshall Avenue passed 08-31-06 >>> BUILDING DEPARTMENT 08/30/06 8:07 AM > Single family Metro Development Larry 407-470-2116 BP05-4151 - _ _...................... ___---- ---- BUILDING DEPARTMENT - Re: 2437 Marshall Avenue 1 From: CATHY LOTEMPIO To: DEPARTMENT, BUILDING Date: 8/30/2006 4:12 pm Subject: Re: 2437 Marshall Avenue Approved 8.30.06 Mike Watson Cathy J. LoTempio Customer Service Rep Public Works Department 407-330-5627 fax# 407-330-5601 >>> BUILDING DEPARTMENT 8/30/2006 8:07 am >>> Single family Metro Development Larry 407-470-2116 BP05-4151 - ----- --------------- -_._.. BUILDING DEPARTMENT - Re: Fwd. 2437 Marshall Avenue CLEAR 8/30/06 1 _.._.,—.....�........_.... _ _ . _ ........_.__ — _ _---------------- _--------- _ - --- ---- _ __ From: RICHARD BLAKE To: BUILDING DEPARTMENT Date: 8/30/2006 4:01 pm Subject: Re: Fwd: 2437 Marshall Avenue CLEAR 8/30/06 CLEARED 8/30/06 Richard Blake City of Sanford Utility Engineer 407-330-5609 >>> ED WOODS 1:10 pm Wednesday, August 30, 2006 >>> >>> RICHARD BLAKE 08/30/06 8:45 AM >>> Richard Blake City of Sanford Utility Engineer 407-330-5609 >>> BUILDING DEPARTMENT 8:07 am Wednesday, August 30, 2006 >>> Single family Metro Development Larry 407-470-2116 BP05-4151 IMPt —KYANT: In these spaces, copy the corresponding information from Section A. I For Insurance Company Use: I ) or P.O. Route and Box No. 2437 Marshall Avenue City Sanford StateFLZIP Code 32771 SECTION D - SURVEYOR, ENGINEER, OR ARCHITECT CERTIFICATION (CONTINUED) Copy both sides of this Elevation Certificate for (1) community official, (2) insurance agenticompany, and (3) building owner. Comments Item e) in Section C2 is Air Conditioner on Concrete Pad Signature Date 47' Check here H attachments SECTION E - BUILDING ELEVATION INFORMATION (SURVEY NOT REQUIRED) FOR ZONE AO AND ZONE A (WITHOUT BFE) For Zones AO and A (without BFE), complete Items E1-E5. If the Certificate is intended to support a LOMA or LOMR-F request, complete Sections A, B, and C. For Items E1-E4, use natural grade, if available. Check the measurement used. In Puerto Rico only, enter meters. El. Provide elevation information for the following and check the appropriate boxes to show whether the elevation is above or below the highest adjacent grade (HAG) and the lowest adjacent grade (LAG). a) Top of bottom floor (including basement, crawl space, or enclosure) is ❑ feet ❑ meters ❑ above or below the HAG. b) Top of bottom floor (including basement, crawl space, or enclosure) is ❑ feet ❑ meters ❑ above or ❑ below the LAG. E2. For Building Diagrams 6-8 with permanent flood openings provided in Section A Items 8 and/or 9 (see page 8 of Instructions), the next higher floor (elevation C2.b in the diagrams) of the building is ❑ feet ❑ meters ❑ above or ❑ below the HAG. E3. Attached garage (top of slab) is ❑ feet ❑ meters ❑ above or ❑ below the HAG. E4. Top of platform of machinery and/or equipment servicing the building is ❑ feet ❑ meters ❑ above or ❑ below the HAG. E5. Zone AO only: If no flood depth number is available, is the top of the bottom floor elevated in accordance with the community's floodplain management ordinance? ❑ Yes ❑ No ❑ Unknown. The local official must certify this information in Section G. SECTION F - PROPERTY OWNER (OR OWNER'S REPRESENTATIVE) CERTIFICATION The property owner or owner's authorized representative who completes Sections A, B, and E for Zone A (without a FEMA-issued or community -lashed BFE), or Zone AO must sign here. The statements in Sections A, A and E are correct to the best of my knowledge. Property Owner's or Owner's Authorized Representative's Name Address City . State ZIP Code Signature Date Telephone Comments oft hem I NW&HO SECTION G - COMMUNITY INFORMATION (OPTIONAL) The local official who is authorized by law or ordinance to administer the community's floodplain management ordinance can complete Sections A, B, 1C (or E), and G of this Elevation Certificate. Complete the applicable item(s) and sign below. Check the measurement used in Items G8. and G9. G1. ❑ The information in Section C was taken from other documentation that has been signed and sealed by,a licensed surveyor, engineer, or architect who is authorized by law to certify elevation information. (Indicate the source and date of the elevation data in the Comments area below.) G2. ❑ A community official completed Section E for a building located in Zone A (without a FEMA-issued or community -issued BFE) or Zone AO. G3. ❑ The following information (Items G4.-G9.) is provided for community floodplain management purposes. G4. Permit Number G5. Date Permit Issued G6. Date Certificate Of Compliance/dccupancy Issued G7. This permit has been issued for: ❑ New Construction ❑ .Substantial Improvement G8. Elevation of as -built lowest floor (including basement) of the building: _❑ feet ❑ meters (Pk) Datum G9. BFE or (in Zone AO) depth of flooding at the building site: ❑ feet ❑ meters (PR) Datum Local Official's Name Title Community Name Telephone Signature Date Comments 171 Check here i<attat�Iffleifta FEMA Form 81-31, February 2006 Replaces all previous editlons SCALE 1" = 20' BOUNDARY SURVEY LOT 15 FND 1 /2" IRC "PLS 5238' 6' CHAIN LINK FENCE^aY o^ 'o CERTIFIED TO: Nancy V. Sanchez Absolute Title Agency Fidelity National Title Insurance Company �o Central Florida Educators FCU 1-1 a- O � LEGAL DESCRIPTION �'0 LOT 5, BLOCK 5, 3RD SECTION DREAMWOLD, ACCORDING TO THE PLAT THEREOF AS RECORDED IN PLAT BOOK 4, PAGE 70 OF THE PUBLIC RECORDS OF SEMINOLE COUNTY, FLORIDA. LOT 6 0Y10 Z9� rQ, WOOD POWER POLE Q CLEAN OUT @ IRON ROD & CAP .+ SPOT ELEVATION --ii /. XI•1 :' CONC CONCRETE CB CONCRETE BLOCK WF WOOD FRAME WM WATER METER COV COVERED IRON ROD AND CAP IRC PIPE FND FOUND OHW OVER HEAD WIRE P PLAT M I MEASURED N&D NAIL AND DISK ID IDENTIFICATION NOTES SET 5/8" IRC "LB 6771" LOT 16 6' WOOD FENCE N00'09'34"W (M) 59.63' (M) 60.00' (P) 7' unurY EASEMENT SEPTIC TANK DRAIN FEILD LOT 5 BLOCK 5 D' 21.70' 0 LOT 17 FND 1/2" IRC "PLS 5238" n �9ry �E a c� 00 COV I CONC to to to U7 #2437 1 STORY CB & WF RESIDENCE FINISHED FLOOR= 37.37' m � N O 13.70' I lal N 3.00' AC ON do u CONC PAD I n rn 00 Z 21,34' CONC N DRIVE I LOT 4 SW CORNER BLOCK 5 60.00' (P)wM �eN0012'59' (M) 59.90' (M) O 252.54' (M) FND 1 /2" IRC OHW "PLS 5238' M� �y. MAILBOX ON ASPHALT PAVEMENT CONC PAD MARSHALL AVENUE 1. DATE OF FIELD SURVEY: 8/23/06 REVISED: 9/7/06 ADDED NOTE 7. 2. BEARINGS SHOWN HEREON ARE REFERENCED TO THE WEST LINE OF LOT 1, SAID BEARING BEING N00'27.56"W (ASSUMED DATUM). 3. ELEVATIONS SHOWN HEREON ARE REFERENCED TO SEMONOLE COUNTY BENCH MARK #5085201, BEING A NAIL & DISK HAVING AN ELEVATION OF 34.626' NAVD 1988. 4. UNDERGROUND IMPROVEMENTS AND/OR UTILITIES, IF ANY, WERE NOT LOCATED DURING THE CONDUCT OF THIS SURVEY. 5. THIS SURVEY ONLY REFLECTS MATTERS OF RECORD AS PROVIDED BY THE CLIENT. THE SURVEYOR HAS MADE NO INVESTIGATION OR INDEPENDENT SEARCH FOR EASEMENTS, RIGHTS OF WAY, ENCUMBRANCES OR RESTRICTIONS THAT MAY BE FOUND IN THE PUBLIC RECORDS OF SEMINOLE COUNTY, FLORIDA. 6. SUBJECT LAND SHOWN HEREON LIES IN FLOOD ZONE "X" (AREAS OUTSIDE THE 500—YEAR FLOODPLAIN) ACCORDING TO THE FEDERAL EMERGENCY MANAGEMENT AGENCY, FLOOD INSURANCE RATE MAP, COMMUNITY No.120294, PANEL 0045, SUFFIX E, HAVING AN EFFECTIVE DATE: APRIL 17,1995. 7. THE FINISHED FLOOR ELEVATION OF THE STRUCTURE LOCATED ON THE SUBJECT PROPERTY SHOWN HEREON MEETS OR EXCEEDS THE REQUIREMENTS SET FORTH IN CHAPTER 18. SECTION 18-4 (a) OF THE SANFORD CITY CODE. CPR Go CENTRAL FLORIDA CONSULTING SURVEYORS 629 Maitland Avenue - Altamonte Springs, FL 32701 Tel: (407) 767-0166 Fax: (407) 767-8558 email: cfcs6771@cfi.rr.com Certificate of Authorization #LB6771 1 HEREBY CERTIFY THAT THIS BOUNDARY SURVEY MEETS THE MINIMUM TECHNICAL STANDARDS SET FORTH BY THE FLORIDA BOARD OF PROFESSIONAL SURVEYORS AND MAPPERS IN CHAPTER 61G17-6, FLORIDA ADMINISTRATIVE CODE RSUANT%TOO SECTION 472.027, FLORIDA STATUTES. 74 PAUL D. WATKINS PSM # 6315 NOT VALID WITHOUT THE SIGNATURE AND RAISED SEAL OF A FLORIDA LICENSED SURVEYOR AND MAPPER 0 MTV MIKE TANNOVS ENGINEERING IN CORPORATE D 261 Live Oaks Boulevard - Casselberry • Florida • 32707 Tel: 407-332-8688 • Fax: 407-332-9598 • Email: MTEincorporated@aol.com FIELD REPORT Project Name/ 7 /hA"OW1. AU C Project Number: Client: Y 1' 7 . iJ Date: 1-e� MTE, Inc. Representative: 0 T 7?1F1AL--x/ A. to U.S. DEPARTMENT OF HOMELAND SECURITY Federal -Emergency Management Agency National Flood Insurance Program Al ELEVATION CERTIFICATE Important: Read the instructions on pages 1-8. SECTION A - PROPERTY INFORMATION Metro Development Group, Inc. OMB No.1660-0008 Exoires February 28.2009 For 1 A2. Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. I Company NAIL Number I 2437 Marshall Avenue 11 City Sanford State FL ZIP Code32771 A3. Property Description (Lot and Block Numbers, Tax Parcel Number, Legal Description, etc.) Lot 5, Block 5, 3rd Section Dreamwold, Plat Book 4, Page70, Seminole Co.,FL A4. Building Use (e.g., Residential, Non -Residential, Addition, Accessory, etc.) Residential A5. Latitude/Longitude: Lat. N28°47'15" Long. W81°16'45" Horizontal Datum: ❑ NAD 1927 ® NAD 1983 A6. Attach at least 2 photographs of the building if the Certificate is being used to obtain flood insurance. A7. Building Diagram Numberl A8. For a building with a crawl space or enclosure(s), provide A9. For a building with an attached garage, provide: a) Square footage of crawl space or enclosure(s) sq ft a) Square footage of attached gartrge i AM eq ft b) No. of permanent flood openings in the crawl space or b) No. of permanent flood openings in the attached garage enclosure(s) walls within 1.0 foot above adjacent grade walls within 1.0 foot above adjacent grade c) Total net area of flood openings in A8.b sq in c) Total net area of flood openings in A9.b _ sq In SECTION B - FLOOD INSURANCE RATE MAP (FIRM) INFORMATION 61. NFIP Community Name & Community Number B2. County Name B3. State { City Of Sanford 120294 Seminole FL B4. Map/Panel Number B5. Suffix B6. FIRM Index Date B7. FIRM Panel Effective/Revised Date B8. Flood Zone(s) B9. Base Flood Elevatfoh(s) (Zone AO, use base flood depth) 0045 E April 17, 1995 April 17, 1995 X N/A B10. Indicate the source of the Base Flood Elevation (BFE) data or base flood depth entered in Item B9. ❑ FIS Profile ® FIRM ❑ Community Determined ❑ Other (Describe) 611. Indicate elevation datum used for BFE in Item B9: ❑ NGVD 1929 ❑ NAVD 1988 ® Other (Describe) !3 B12. Is the building located in a Coastal Barrier Resources System (CBRS) area or Otherwise Protected Area (OPA)? ❑Yes ONo Designation Date [] CBRS ❑ OPA SECTION C - BUILDING ELEVATION INFORMATION (SURVEY REQUIRED) C1. Building elevations are based on: ❑ Construction Drawings' ❑ Building Under Construction' 0 Finished Construction •A new Elevation Certificate will be required when construction of the building is complete. C2. Elevations -Zones Al-A30, AE, AH, A (with BFE), VE, VI-V30, V (with BFE), AR, AR/A, AR/AE, AR/A1-A30, AR/AH, AR/AO. Complete Items C2.a-g below according to the building diagram specified in Item A7. Benchmark Utilized Seminole County #5065201Vertical Datum NAVD 1988 Conversion/Comments 3r; Check the measurement used. a) Top of bottom floor (including basement, crawl space, or enclosure floor)_ 37.4 ® feet ❑ meters (Puerto Rico only) b) Top of the next higher floor _ - ❑ feet ❑ meters (Puerto Rico only) c) Bottom of the lowest horizontal structural member (V Zones only) _ ❑ feet ❑ meters (Puerto Rico only) d) Attached garage (top of slab) 2§1 ® feet ❑ meters (Puerto Rioo only) e) Lowest elevation of machinery or equipment servicing the building 2Z.9 ® feet ❑ meters (Puerto Rico only) (Describe type of equipment in Comments) f) Lowest adjacent (finished) grade (LAG) 36.4 ® feet ❑ meters (Puerto Rico only) g) Highest adjacent (finished) grade (HAG) 36.2 ® feet ❑ meters (Puerto Rico only) SECTION D - SURVEYOR, ENGINEER, OR ARCHITECT CER ICATION This certification is to be signed and sealed by a land surveyor, engineer, or architect authorized by law to certify elevation information. I certify that the information on this Certificate represents my best efforts to interpret the data adellab/e. I understand that any false statement may be punishable by fine or imprisonment under 18 U.S. Code, SecNor► 1001. Check here if comments are provided on back of form. �E \ Certifier's Name Paul D. Watkins License Number PSM 631 Title Professional Surveyor and Mapper Company Name Central Florida Consulting Surveyors, Inc Address 629 Maitland Avenue City Altamonte Springs State FL ZIP Code 32701 Signature Date Telephone (407) 767-0166 FEMA Form 81-31, February 2006 See reverse side for continuation. Replaces all previous editions w CITY OF SANFORD PERMIT APPLICATION Lo+ 5- Permit #: UJ J— 'f'I Job Address: 7— L4 Description of Work: I Square Footage Historic District: Zoning: Value of Work: S r Sir . co Permit Type: Building Electrical Mechanical Plumbing Fire Sprinkler/Alarm Pool Electrical: New Service — # 4 AMPS Addition/Alteration Chapge of Service Temporary Pole Mechanical: Residential Non -Residential Replacement New — (Duct Layout & Energy Calc. Required) 0 -�r7 Plumbing/ New Commercial: # of Fixtures # of Water & Sewer Lines # of Gas Lines Plumbing/New Residential: # of ,�4er Closets Plumbing Repair — Residential or Commercial Occupancy Type: Residential Commercial Industrial Construction Type: # of Stories: # of Dwelling Units: Flood Zone: (FEMA form required ) Owners Name & Address: Phone: Contractor Name & Address: Phone & Fax: Bonding Company: Address: Mortgage Lender: Address: Architect/Engineer: Address: Phone: Fax: Application is hereby made to obtain a permit to do the work and installations as indicated. 1 certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, and AIR CONDITIONERS, etc. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY, IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE: In addition to the requirements of this permit, there may be additional restrictions aplkable to this this county, and there may be additional permits required from other governmental eplities s h as)water. man Acceptance of permit is verification that I will notify the owner of the Signature of Owner/Agent Date Print Owner/Agent's Name Signature of Notary -State of Florida Date Owner/Agent is _ Personally Known to Me or _ Produced ID APPROVALS: ZONING: UTIL: _ FD: Special Conditions: Rev 03/2006 of of Signature Contractor/Agent is Produced ID _ that may be found in the public records of tgement istricts, state agencies, or federal agencies. Lien La . FS 713. Date o Florida Date 4,, P`*e Dawn A. Canada * : Commission # DD356104 Expires October 11, 2008 Personally Kno %nWTroyFain -jnwmm# inc WO-3 s7019 ENG: BLDG: • TRI-TECH AIR CONDITIONING, INC. -"'R Gll Al'R i;oat �WKO. W. 100 HOW BLVD. CASSEIBERRV, El. 31707 Power of Attorney Hereby name and appoint. V V kq&---- ' Vn _ -------- of Tri-Tech Air Conditioning, Inc. to be my lawful attorney. In fact to act for me and apply to the� t� _ _—vA�C--------- for an H. V.A.C. permit for work to be performed at in L01 -- ------------------------------------- L1L I_- I a.L4&t-u _.UUc - - - ----------------------- And to sign my name and do Charles T. Trier CAC04264E :) this appointment. Acknowledged: Sworn to and subscribed before me this ----------- day of Notary Public - State of Florida - cSc'r ocl e ��.1._(f� My Commission Expires oPP pva�� Dawn A. Canada Commission # DD356104 Expires October 11, C1F W. %r4W Tmy Fain • InWr/nc•. Inc lop. 5101i CITY OF SANFORD PERMIT APPLICATION Permit # ki\5 � Date: w -,),k 'aL Job Address:�'� c S�s4l\ Description of Work: ' p �~�' ` ±h Total Square Footage Historic District: Zoning: Value of Work: Sz3te:z�j Permit Type: Building Electrical Mechanical Plumbing Fire Sprinkler/Alarm Pool Electrical: New Service — # of AMPS Addition/Alteration Change of Service Temporary Pole Mechanical: Residential Non -Residential Replacement New (Duct Layout & Energy C:alc. Required) Plumbing/ New Commercial: # of Fixtures _ # of Water & Sewer Lines # of Gas Lines Plumbing/New Residential: # of Water Closets Plumbing Repair — Residential or Commercial Occupancy Type: Residential 44- Commercial Industrial Construction Type: # of Stories: \ # of Dwelling Units: Flood Zone: (FEMA form required) Owners Name & Address: Phone: A6) Contractor Name & Address: "^ ^c '.x►<-pu �, �. c tl�%1 i State License Number:- _ Phone & Fax: Contact Person: Phone: Als-1 1L Bonding Company: Address: Mortgage Address: Architect/ Address: Fax: Application is hereby made to obtain a permit to do the work and installations as indicated. 1 certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, and AIR CONDITIONERS, etc. OWNER'S AFFIDAVIT: 1 certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such a?-wat,,r management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requiremen%s off n�a L`3 , FS 713. Signature of Owner/Agent Print Owner/Agent's Name Date Signature of Notary -State of Florida Date Owner/Agent is _ Produced ID APPROVALS: ZONING: Special Conditions: Rev 0312006 Personally Known to Me or L1y1111 FD: Date Name Signature of Notary -State of Florida Date Contractor/Agent is Personally Known to Me or Produced ID ENG: BLDG: c:>(- Permit # : �5 5 Job Address: A Description of Work: Historic District: Zoning: CITY OF SANFORD PERMIT APPLICATION � Date: 3 .4 d v Total Square Footage N6 Value of Work: $ 9000 Permit Type: Building Electrical " Mechanical Plumbing Fire Sprinkler/Alarm Pool Electrical: New Service — # of AMPS 150 Addition/Alteration Change of Service Temporary Pole Mechanical: Residential Non -Residential Replacement New (Duct Layout & Energy Calc. Required) Plumbing/ New Commercial: # of Fixtures # of Water & Sewer Lines # of Gas Lines Plumbing/New Residential: # of Water Closets Plumbing Repair — Residential or Commercial Occupancy Type: Residential X Commercial Industrial Construction Type: 1JIv- # of Stories: # of Dwelling Units: Flood Zone: (FEMA form required ) Owners Name & Address: ^ Phone: Contractor N � /^► & Address: /lE tv l o4 L �rI State License Number: itQ�`_ _ Phone & Fax: t 7 - 47 • ontact Person: r' iv L✓ i Phone: Y07-.d/ %! J Bonding Company: Address: Mortgage Lender: Address: Architect/Engineer: Address: Phone: Fax: Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. 1 understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, and AIR CONDITIONERS, etc. OWNER'S AFFIDAVIT: 1 certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that 1 will notify the owner of the property of the require 7zra Lien Law, 7 3. Signature of Owner/Agent Date Signature of Contractor/Agent Date 446 1.1 WTIr Print Owner/Agent's Name Print tractor�/Age 's Name Signature of Notary -State of Florida Date Signature of Notary -State of Florida Date Owner/Agent is _ Personally Known to Me or Produced ID APPROVALS: ZONING: Special Conditions: Rev 03/2006 UTIL: FD: Contractor/Agent is _ Personally Known to Me or Produced ID ENG: BLDG: Q REVISION PERMIT # O. - / 5/ DATE �3 �Z& lD G PROJECT ADDRESS Qz137 A eneve CONTRACTOR /i%jryc vc%arr�e �rOUI7, roc. PHONE # 7-�5 -�7// FAX # �7-.599- 733 DESCRIPTION OF REVISIONc . �SCd �i tSS ,�r,Gli/ICG /i�ri UTILITY DEPT FIRE PREVENTION PLANNING BUILDING I I II I 1 1 I p p p 0 I I TRUSSWAY, LTD TR Build Right From The Start! www. trusswa y. com ROOF TRUSS ENGMEERING FOR: SANFORD HOUSING PROJECT SANFORD, FLORIDA 3UILDING TYPES: LDG I�'J MANUFACTURING, SALES AND DESIGN LOCATIONS LOCATION _ACWORTH, GA _ _ _ OFFICE NUMBER 770) 975-5777 ._ FAx NUMBER.,. A770) 975-3322_ _ CHANDLER AZ 602 273-7323 4$096i-0729 CLINTON NC (910) 299-0690 910 299-0692 Co_WP_ENS, SC 864) 463-2914 t864) 463.2917 FRED_ERICKSBURG, VA (540) 898-3477 _. �5410) 898-3885 HOUSTON TX (713) 691-6900 (7i 3) 691-2064� HURST TX (817) 589-1467 (817) 595-1097 ! JACKSON MI (517) 764,1405 (435) 603-3756 LIBERTY NC _ _ _ MICHIGAN CITY, IN ORLANDO, FL (336) 622_-2244 (219) 872-3608 (407) 857-2777 (336) 622-3111 (800) 859-1166 (407) 851-7899 _ SPARTA, MI (616) 887-8264 (800) 748-0202 SALES AND DESIGN LOCATIONS 7• • • A_STIN� TX_ E_W_EE VALLEY, CHARLOTTE, NC HIGH POINT, NC INGELSIDE IL PATCHOUE, NY 7 1 (815) 344-4740 (631) 363_-0151 H 336L883-6939 815 344-4740 631) 363-0054 I.\ 6h,�1b,-.MA 885o Trussway Blvd. Orlando, FL 32824 Phone: (407) 857-2777 Fax: (4o7) 851-7899 Operations Mgr. Jim Thomas Design Mgr. Rene Pena Sales Rep. FRANK RODRIGUEZ ROOF TRUSS ENGINEERING FOR: SANFORD HOUSING PROJECT SANFORD, FLORIDA BUILDING TYPES: BLDC 1-7 TRUSSWAY JOB NUMBER: 53107 TRANSMITTED TO: METRO DEVELOPMENT JOBSITE CONTACT: MR. GARYHUGGINS 0 ---------------------- VERSION 1.01 - 06/24/03 Trussway, Ltd. Southeastern Division 8850 Trussway Blvd. Orlando, FL 32824 Ph. (407) 857-2777 Fax (407) 857-7855 Project: Metro Development Sanford Housing City of Sanford, Florida, Seminole County Truss Design Loads (Individual Drawings may show Special Loading Conditions) Gravity - Roof 40 psf Total Load Wind: 120 mph as per ASCE 7-98 & FBC2001, Truss design software: Mitek202O Trusses are designed for an Enclosed building condition as per building designer, assuming doors and windows are protected from windborne debris impact as per Fla. Bldg. Code 1606.1.4 Name, Address and License # of Structural Engineer of Record for the Building: Name: Kenneth H. Ehlers License # 18243 Address: 6034 Falconbridge Place, Mount Dora, FL 32757 This package includes truss design drawings with individual date of design. These trusses are listed below and on the attached spreadsheet. These truss designs have been prepared by Trussway Ltd., under my direct supervision based on the parameters provided and shown on the truss drawings. The seal on this letter indicates acceptance of professional engineering responsibility solely for the truss drawings attached. The suitability and use of these components for any particular building is the responsibility of the building designer, per ANSI/TPI-1995 Sec.2. This is in accordance with Rule 61 G5-31.003, Section 5 of the Florida Board of Professional Engineers. R01-RG2, HR01-3, J01-J210A, V01-V2-4 March 10, 2006 Delegated Truss Design Engineer Date Registered Professional Engineer, State of Florida Iqbal H.A. Gagan, PE / FL License Number # 25389 8850 Trussway Boulevard Orlando, Florida 32824 407-857-2777 TRUSSWAY, LTD. - ROOF SPREAD SHEET PROJECT: SANFORD HOUSING Job #: 53107 Builder: METRO DEVELOPMENT rev: City: SANFORD Notes: State: FL Plant: Orl Dwn By: Bc Chk By: Salesmen: ds Item Count: 40 Pitch Span Description BLDG 1 2 3 4 5 6 7 Total LVL 1 1 1 1 1 1 1 TYPE FCTR REV I I I I I I I 4.00 38-00-00 ROOF TRUSS R01 59.81 1 1 1 1 1 1 1 7 4.00 38-00-00 ROOF TRUSS R01A('2F 56.08 2 2 2 2 2 2 2 14 4.00 38-00-00 ROOF TRUSS R02 49.41 1 1 1 1 1 1 1 7 4.00 38-00-00 ROOF TRUSS R02A 48.63 1 1 1 1 1 1 1 7 4.00 38-00-00 ROOF TRUSS R03 48.63 1 1 1 1 1 1 1 7 4.00 38-00-00 ROOF TRUSS R03A 47.84 1 1 1 1 1 1 1 7 4.00 38-00-00 ROOF TRUSS R04 50.19 1 1 1 1 1 1 1 7 4.00 38-00-00 ROOF TRUSS R04A 49.41 1 1 1 1 1 1 1 7 4.00 38-00-00 ROOF TRUSS R05 50.19 1 1 1 1 1 1 1 7 4.00 38-00-00 ROOF TRUSS R05A 51.76 1 1 1 1 1 1 1 7 4.00 38-00-00 ROOF TRUSS R06 52.55 1 1 1 1 1 1 1 7 4.00 38-00-00 ROOF TRUSS R06A 52.55 1 1 1 1 1 1 1 7 4.00 38-00-00 ROOF TRUSS R07 48.24 5 5 5 5 5 5 5 35 4.00 21-04-00 ROOF TRUSS R20 32.16 1 1 1 1 1 1 1 7 4.00 21-04-00 ROOF TRUSS R21 25.88 1 1 1 1 1 1 1 7 4.00 21-04-00 ROOF TRUSS R22 24.31 2 2 2 2 2 2 2 14 4.00 21-04-00 ROOF TRUSS R23 23.53 3 3 3 3 3 3 3 21 4.00 24-04-00 ROOF TRUSS R30 30.98 1 1 1 1 1 1 1 7 4.00 24-04-00 ROOF TRUSS R31 34.51 1 1 1 1 1 1 1 7 4.00 24-04-00 ROOF TRUSS R32 30.59 1 1 1 1 1 1 1 7 4.00 24-04-00 ROOF TRUSS R33 32.55 1 1 1 1 1 1 1 7 4.00 07-00-00 ROOF TRUSS R40 8.24 1 1 1 1 1 1 1 7 4.00 07-00-00 ROOF TRUSS R41 7.45 1 1 1 1 1 1 1 7 4.00 07-00-00 ROOF TRUSS RG1 10.39 1 1 1 1 1 1 1 7 4.00 06-04-00 ROOF TRUSS RG2 10.39 1 1 1 1 1 1 1 7 2.83 09-09-05 ROOF TRUSS HR01 11.76 5 5 5 5 5 5 5 35 2.83 04-01-07 ROOF TRUSS HR02 5.10 2 2 2 2 2 2 2 14 2.83 03-11-05 ROOF TRUSS HR03 3.92 1 1 1 1 1 1 1 7 4.00 01-00-00 ROOF TRUSS J01 2.35 16 16 16 16 16 16 16 112 4.00 03-00-00 ROOF TRUSS J03 3.92 12 12 12 12 12 12 12 84 4.00 05-00-00 ROOF TRUSS J05 5.10 10 10 10 10 10 10 10 70 4.00 07-00-00 ROOF TRUSS J07 T45 22 22 22 22 22 22 22 154 4.00 02-10-08 ROOF TRUSS J210 3.92 1 1 1 1 1 1 1 7 4.00 02-10-08 ROOF TRUSS J210A 3.14 1 1 1 1 1 1 1 7 4.00 03-10-08 ROOF TRUSS Vol 3.14 2 2 2 2 2 2 2 14 4.00 07-10-08 ROOF TRUSS V02 6.28 1 1 1 1 1 1 1 7 4.00 03-11-04 ROOF TRUSS V2 3.92 1 1 1 1 1 1 1 7 4.00 05-11-04 MONO TRUSS V3 5.49 1 1 1 1 1 1 1 7 4.00 03-11-04 MONO TRUSS V4 3.92 1 1 1 1 1 1 1 7 RH3 7 7 7 7 7 7 7 49 Print Date: 11/04/2005 08:46:58 AM Job iTruss Truss Type 'QtY Ply 153107 / METRO DEW Sanford Housing / Bc 53107 HR01ROOF TRUSS 1 1 j Job Reference (optional) j Trussway, Orlando, FI 6.100 a Sep 17 2004 MiTek Industries, Inc. Wed Oct 26 17:00:06 2005 Page 1 i -1$ 8 5-11-14 9-9-5 1-8-8 5-11-14 3-9-7 Scale = 1:19.5 2x3 11 D 2.83112 2x3 Z� I--" EV2 2 j I F B� E 4x6 = 3x4 = I 5-11-14 + 9-9-5 5-11-14 3-9-7 _ LOADING (psf) SPACING 2-0-0 CSI DEFL in (Inc) I/defl Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.57 Vert(LL) 0.35 B-E >315 240 I MT20 244/190 TCDL 10.0 Lumber Increase 1.25 SC 0.83 Vert(TQ -0.56 B-E >201 180 I BCLL 0.0 ! Rep Stress Incr NO WB 0.24 j Horz(TL) 0.01 E n/a n/a BCDL 10.0 Code FBC2001/ANSI95 I (Matrix) I Weight: 41 lb LUMBER 5) "Fix heels only" Member end fixity model was used TOP CHORD 2 X 4 SYP No.2 in the analysis and design of this truss. BOT CHORD 2 X 4 SYP No.2 6) In the LOAD CASE(S) section, loads applied to the WEBS 2 X 4 SYP No.3 face of the truss are noted as front (F) or back (B). 7) NOTE: Refer to yellow bracing and/or T-1 sheet for BRACING more information. TOP CHORD 8) NOTE: The seal on this drawing indicates Sheathed or 6-0-0 oc purlins, except end verticals. acceptance of professional engineering BOT CHORD responsibility solely for the truss component design Rigid ceiling directly applied or 8-6-11 oc bracing. shown. 9) NOTE: Trusses are designed for an Enclosed REACTIONS (lb/size) building condition as per building designer, E = 603/Mechanical assuming doors and windows are protected from j B = 440/0-11-0 windborne debris impact as per Fla. Bldg. Code Max Horz 1606.1.4 B = 264(load case 3) Max Uplift LOAD CASE(S) E _-309(load case 3) Standard B =-281(load case 3) 1) Regular: Lumber Increase=1.25, Plate Increase=1.25 FORCES (lb) Uniform Loads (plf) Maximum Compression/Maximum Tension Vert: A-F=-60 TOP CHORD Trapezoidal Loads (pif) A-F = 0/18 B-F = 0/18 Vert: F=0(F=30, B=30)-to-D=-147(F=-43, B=-43), B-C=-792/247 C-D=-110/33 B=-2(F=9, B=9)-to-E=-49(F=-14, B=-14) D-E _-2001120 j BOT CHORD B-E _-470/758 WEBS C-E _-8041427 I NOTES (7-9) i 1) Wind: ASCE 7-98; 120mph (3-second gust); h=15ft; TCDL=S.Opsf; BCDL=5.Opsf; Category ll; Exp B; enclosed; MWFRS interior zone; cantilever left and right exposed; porch left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33. j 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. L- --� 3) Refer to girder(s) for truss to truss connections. 14) Provide mechanical connection (by others) of truss to IQBAL H.A. GAGAN P.E. # 25389 bearing plate capable of withstanding 309 lb uplift at 8860 Trussway dot l24vard joint E and 281 lb uplift at joint B. Orlando, FL L., o 4 24UG JJob Truss Truss Type otv Ply 53107 / METRO DE V/ Sanford Housing / Bc 53107 HR02 ! ROOF TRUSS 1 1 j Job Reference (optional) Trussway, Orlando, F1 6.100 a Sep 17 2004 MiTek Industries, Inc. Wed Od 26 17:00:32 2005 Page 1 4-1-7 i 1-8-8 4-1-7 i Scale = 1:9.8i C 2.83 12 ~ E B T1 iy I^!^_ D 3x3 4-1-0 4-,1-7 4-1-0 0-0-7 LOADING (psf) SPACING 2-0-0 CSI I DEFL in (loc) I/deft L/d PLATES GRIP TCLL 20.0 Plates Increase 1.25 i TC 0.26 Vert(LL) 0.02 B-D >999 240 MT20 244/190 TCDL 10.0 Lumber Increase 1.25 BC 0.11 Vert(TL) -0.02 B-D >999 180 BCLL 0.0 Rep Stress Incr NO ( WB 0.00 Horz(TL) -0.00 C BCDL 10.0 Code FBC2001/ANS195 (Matrix) IWeight: 151b LUMBER 4) Provide mechanical connection (by others) of truss TOP CHORD 2 X 4 SYP No.2 to bearing plate capable of withstanding 12 lb uplift at BOT CHORD 2 X 4 SYP No.2 joint C, 185 lb uplift at joint B and 42 lb uplift at joint D. 5) Beveled plate or shim required to provide full BRACING bearing surface with truss chord at joint(s) C. TOP CHORD 6) "Fix heels only" Member end fixity model was used Sheathed or 4-1-7 oc purlins. in the analysis and design of this truss. BOT CHORD 7) In the LOAD CASE(S) section, loads applied to the Rigid ceiling directly applied or 10-0-0 oc bracing, face of the truss are noted as front (F) or back (B). 8) NOTE: Refer to yellow bracing and/or T-1 sheet for REACTIONS (lb/size) more information. C = 48/0-3-8 9) NOTE: The seal on this drawing indicates B = 196/0-11-5 acceptance of professional engineering D = 27/Mechanical responsibility solely for the truss component design Max Horz shown. B = 40(load case 3) 10) NOTE: Trusses are designed for an Enclosed Max Uplift building condition as per building designer, C =-12(load case 4) assuming doors and windows are protected from B =-185(load case 3) windborne debris impact as per Fla. Bldg. Code i D =-42(load case 3) 1606.1.4 Max Grav C = 48(load case 1) LOAD CASE(S) B = 196(load case 1) Standard D = 64(load case 2) 1) Regular: Lumber Increase=1.25, Plate Increase=1.25 FORCES (lb) Uniform Loads (plf) Maximum Compression/Maximum Tension Vert: A-E=-60 TOP CHORD Trapezoidal Loads (plf) A-E = 0/18 B-E = 0/18 Vert: E=-O(F=30, B=30)-to-C=-62(F=-1, B=-1), B-C = -20/7 B=-2(F=9, B=9)-to-D=-21(F=-0, B=-0) BOT CHORD B-D = 0/0 NOTES (8-10) 1) Wind: ASCE 7-98; 120mph (3-second gust); h=15ft; TCDL=5.Opsf; BCDL=5.Opsf; Category Il; Exp B; enclosed; MWFRS interior zone; cantilever left and right exposed ; porch left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33. l IQBAL N.A. GAGAN L#25389 2) This truss has been designed for a 10.0 psf bottom 8850 Trussw chord live load nonconcurrent with any other live loads. Orlando, R. 32824 3) Refer to girder(s) for truss to truss connections. 7flf I Itu, Job ;Truss Truss Type ocy Plv 53107 /METRO DEV/ Sanford Housing / Bc -- 53107 i HR03 i ROOF TRUSS 1 1 Job Reference (optional) Trussway, Orlando, FI 6.100 a Sep 17 2004 MiTek Industries, Inc. Wed Oct 26 17:00:32 2005 Page 1 i i 1-8-8 3-11-5 1-8 8 3-11-5 Scale = 1:9.51 C 2.83 ;12 B N E T7 i B1 d J. I 3x3 = I 3-11-5 - J 3-11-5 j LOADING (psf) I SPACING 2-0-0 I CSI I DEFL in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.46 Vert(LL) -0.01 B-D >999 240 i MT20 244/190 TCDL 10.0 Lumber Increase 1.25 BC 0.17 Vert(TL) -0.01 B-D >999 180 BCLL 0.0 Rep Stress Incr NO WB 0.00 Horz(TL) -0.00 C n/a n/a BCDL 10.0 Code FBC2001/ANS195 (Matrix) I Weight: 15lb --, LUMBER 5) "Fix heels only" Member end fixity model was used j TOP CHORD 2 X 4 SYP No.3 in the analysis and design of this truss. j BOT CHORD 2 X 4 SYP No.3 6) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). BRACING 7) NOTE: Refer to yellow bracing and/or T-1 sheet for TOP CHORD more information. Sheathed or 3-11-5 oc purlins. 8) NOTE: The seal on this drawing indicates BOT CHORD acceptance of professional engineering Rigid ceiling directly applied or 10-0-0 oc bracing. responsibility solely for the truss component design shown. REACTIONS (lb/size) 9) NOTE: Trusses are designed for an Enclosed C = 39/Mechanical building condition as per building designer, B = 192/0-11-5 assuming doors and windows are protected from D = 24/0-3-8 windborne debris impact as per Fla. Bldg. Code Max Horz 1606.1.4 B = 38(load case 3) Max Uplift LOAD CASE(S) C =-10(load case 4) Standard B-130(load case 3) 1) Regular: Lumber Increase=1.25, Plate Max Grav Increase=1.25 C 39(load case 1) Uniform Loads (plf) B 192(load case 1) Vert: A-E=-60 D - 58(load case 2) Trapezoidal Loads (plf) j Vert: E=-0(F=30, B=30)-to-C=-59(F=O, B=0), FORCES (lb) B=-2(F=9, B=9)-to-D=-20(F=O, B=0) Maximum Compression/Maximum Tension TOP CHORD A-E = 0/18 B-E = 0/18 B-C = -19/5 BOT CHORD B-D = O/0 NOTES (7-9) 1) Wind: ASCE 7-98; 120mph (3-second gust); h=15ft; TCDL=S.Opsf; BCDL=S.Opsf; Category 11; Exp B; enclosed; MWFRS interior zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33. 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Refer to girder(s) for truss to truss connections. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 10 lb uplift at joint IQBAL H.A. GAGAN P.E. IV25389 C and 130 lb uplift at joint B. 8850 Trusswa boulevard -- - - ---_ __-_-- Qdando>.FL^32824------- MAR �+ �w i russ i cuss type i my NI 9 i y ! DEV/ Sanford Housing / Bc 53107 'J01 ;ROOF TRUSS 11 1 I Job Reference (optional) Trussway, Orlando, FI 6.100 a Sep 17 2004 MiTek Industries, Inc. 1Ved Oct 26 17:00:32 2005 Page 1 i -1-2-8 1-0-0 1-2-8 1.0-0 r/ Scale = 1:4.61 A I 1 LOADING (psf) SPACING 2-0-0 TCLL 20.0 Plates Increase 1.25 TCDL 10.0 Lumber Increase 1.25 BCLL 0.0 Rep Stress Incr YES BCDL 10.0 Code FBC20011ANS195 LUMBER TOP CHORD 2 X 4 SYP No.3 BOT CHORD 2 X 4 SYP No.3 BRACING TOP CHORD Sheathed or 1-0-0 oc pudins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) C = -20/Mechanical B = 161/0-4-0 D = 10/Mechanical Max Horz B = 36(load case 4) Max Uplift C =-20(load case 1) B =-128(load case 4) D =-9(load case 4) Max Grav C = 29(load case 4) B = 161(load case 1) D = 19(load case 2) FORCES (lb) Maximum Compression/Maximum Tension TOP CHORD A-B = 0/21 B-C = -27/19 BOT CHORD B-D = 0/0 NOTES (6-8) 1) Wind: ASCE 7-98; 120mph (3-second gust); h=15ft; TCDL=S.Opsf; BCDL=S.Opsf; Category Il; Exp B; enclosed; MWFRS interior zone and C-C Interior(1) zone; cantilever left and right exposed ; porch left exposed; Lumber DOL=1.33 plate grip DOL=1.33. This truss is designed for C-C for members and forces, and for MWFRS for reactions specified. 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Refer to girder(s) for truss to truss connections. CSI DEFL in (loc) I/defl TC 0.23 Vert(LL) -0.00 B >999 BC 0.02 Vert(TL) -0.00 B >999 WB 0.00 Horz(TL) 0.00 C n/a (Matrix) 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 20 lb uplift at joint C, 128 lb uplift at joint B and 9 lb uplift at joint D. 5) "Fix heels only" Member end fixity model was used in the analysis and design of this truss. 6) NOTE: Refer to yellow bracing and/or T-1 sheet for more information. 7) NOTE: The seal on this drawing indicates acceptance of professional engineering responsibility solely for the truss component design shown. 8) NOTE: Trusses are designed for an Enclosed building condition as per building designer, assuming doors and windows are protected from windborne debris impact as per Fla. Bldg. Code 1606.1.4 LOAD CASE(S) Standard e Ud PLATES GRIP 240 MT20 244/190 180 n/a Weight: 5 lb IQBAL H.A. GAGAN, P.E. # 25389 8860 Trussway Boulevard 28 Orlando MAR 1 11 ZUUU 53107 LOADING (psf) TCLL 20.0 TCDL 10.0 BCLL 0.0 BCDL 10.0 Truss J03 1-2-8 B SPACING 2-0-0 Plates Increase 1.25 Lumber Increase 1.25 Rep Stress Incr YES Code FBC2001/ANS195 LUMBER TOP CHORD 2 X 4 SYP No.3 BOT CHORD 2 X 4 SYP No.3 BRACING TOP CHORD Sheathed or 3-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) C = 63/Mechanical B = 214/0-4-0 D = 28/Mechanical Max Horz B = 61(load case 4) Max Uplift C _ -27(load case 4) B = -147(load case 4) D = -28(load case 4) Max Grav C = 63(load case 1) B = 214(load case 1) D = 55(load case 2) FORCES (lb) Maximum Compression/Maximum Tension TOP CHORD A-B = 0/22 B-C = -35116 BOT CHORD B-D = 0/0 ROOFTRUSS NOTES (6-8) 1) Wind: ASCE 7-98; 120mph (3-second gust); h=15ft; TCDL=5.Opsf; BCDL=5.Opsf; Category II; Exp B; enclosed; MWFRS interior zone and C-C Interior(1) zone; cantilever left and right exposed ; porch left exposed; Lumber DOL=1.33 plate grip DOL=1.33. This truss is designed for C-C for members and forces, and for MWFRS for reactions specified. 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Refer to girder(s) for truss to truss connections. 3x3 = Q1y Ply 53107 / METRO DEV/ Sanford 1 1 Job Reference (optional) 6.100 a Sep 17 2004 MiTek Industries, Inc. Wed Oct 26 3-0-0 3-0-0 4.00 12 T1 B1 ng C It) 3-0-0 CSI DEFL in floc) I/deft Ud PLATES GRIP TC 0.27 Vert(LL) 0.01 B-D >999 240 MT20 244/190 BC 0.19 Vert(TL) 0.01 B-D >999 180 WB 0.00 Horz(TL) -0.00 C n/a n/a (Matrix) i Weight: 11lb 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 27 lb uplift at joint C, 147 lb uplift at joint B and 28 lb uplift at joint D. 5) "Fix heels only" Member end fixity model was used in the analysis and design of this truss. 6) NOTE: Refer to yellow bracing and/or T-1 sheet for more information. 7) NOTE: The seal on this drawing indicates acceptance of professional engineering responsibility solely for the truss component design shown. 8) NOTE: Trusses are designed for an Enclosed building condition as per building designer, assuming doors and windows are protected from windborne debris impact as per Fla. Bldg. Code 1606.1.4 LOAD CASE(S) Standard IGBAL H.A. GAG P.E. # 6389 8850 Trusswayy boulevard Orlando, FL. 32824 I] MAR 14 Z05 Job iTruss — Truss Type oty Ply 53107 / METRO DEV/ Sanford Housing / Bc — ! 53107 J05 ROOF TRUSS 1 1 Job Reference (optional) Trussway, Orlando, FI 6.100 a Sep 17 2004 MiTek Industries, Inc. Wed Oct 26 17:00:33 2005 Page 1 j 1-2 8 5-M 1-2-8 5-0-0 10.7t 4.00 12 'a i I fi B 3x3 = 5-0-0 5-0-0 LOADING (psf) TCLL 20.0 SPACING 2-0-0 Plates Increase 1.25 CSI DEFL in (loc) I/deft Ud TC 0.26 Vert(LL) 0.10 B-D >564 240 PLATES GRIP MT20 244/190 TCDL 10.0 Lumber Increase 1.25 BC 0.31 Vert(TQ 0.09 B-D >652 180 BCLL 0.0 Rep Stress Incr YES WB 0.00 I Horz(TL) -0.00 C n/a n/a BCDL 10.0 Code FBC2001/ANSI95 (Matrix) Weight: 17lb LUMBER 4) Provide mechanical connection (by others) of truss TOP CHORD 2 X 4 SYP No.2 to bearing plate capable of withstanding 68 lb uplift at BOT CHORD 2 X 4 SYP No.2 joint C, 183 lb uplift at joint B and 47 lb uplift at joint D. 5) "Fix heels only" Member end fixity model was used BRACING in the analysis and design of this truss. TOP CHORD 6) NOTE: Refer to yellow bracing and/or T-1 sheet for Sheathed or 5-0-0 oc purlins. more information. BOT CHORD 7) NOTE: The seal on this drawing indicates Rigid ceiling directly applied or 10-0-0 oc bracing. acceptance of professional engineering responsibility solely for the truss component design REACTIONS (lb/size) shown. C = 131/Mechanical 8) NOTE: Trusses are designed for an Enclosed B = 285/0-4-0 building condition as per building designer, D = 48/Mechanical assuming doors and windows are protected from Max Horz windborne debris impact as per Fla. Bldg. Code i B = 86(load case 4) 1606.1 A Max Uplift C =-68(load case 4) LOAD CASE(S) B =-183(load case 4) Standard D =-47(load case 4) Max Grav C = 131(load case 1) B = 285(load case 1) D = 95(load case 2) FORCES (lb) Maximum Compression/Maximum Tension TOP CHORD A-B = 0/22 B-C = -51/34 BOTCHORD B-D = 0/0 NOTES (6-8) 1) Wind: ASCE 7-98; 120mph (3-second gust); h=15ft; TCDL=S.Opsf; BCDL=S.Opsf; Category 11; Exp B; enclosed; MWFRS interior zone and C-C Interior(1) zone; cantilever left and right exposed ; porch left exposed; Lumber DOL=1.33 plate grip DOL=1.33. This j truss is designed for C-C for members and forces, and for MWFRS for reactions specified. 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Refer to girder(s) for truss to truss connections. IQBAL H.A. GAGAN P.E. # 25389 Orlando, FL. 32824 MAR 1 ng / Bc 53107 1-2-8 J07 B 3x3 LOADING (psf) SPACING 2-0-0 TCLL 20.0 Plates Increase 1.25 TCDL 10.0 Lumber Increase 1.25 BCLL 0.0 Rep Stress Incr YES BCDL 10.0 I Code FBC2001/ANS195 LUMBER TOP CHORD 2 X 4 SYP No.2 BOT CHORD 2 X 4 SYP No.2 WEBS 2 X 4 SYP No.3 BRACING TOP CHORD Sheathed or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) D = 154/Mechanical B = 367/0-8-0 E = 99/Mechanical Max Horz B = 112(load case 4) Max Uplift D = -92(load case 4) B = -230(load case 4) E _ -73(load case 4) Max Grav D = 154(load case 1) B = 367(load case 1) E = 112(load case 2) FORCES (lb) Maximum Compression/Maximum Tension TOP CHORD A-B = 0122 B-C = -61/0 C-D = -59/42 BOT CHORD B-F = 0/0 E-F = 0/0 WEBS C-F = -71/43 ROOFTRUSS 1 I 1 6.100eSep 1 7-0-0 7-0-0 4.00 12 2x3 I I C i !�W4 F 2x3 11 -0-0 CSI DEFL in (loc) I/defl TC 0.48 Vert(LL) 0.29 E-F >273 BC 0.44 Vert(TL) 0.24 E-F >327 WB 0.01 Horz(TL) -0.01 D n/a (Matrix) L/d PLATES GRIP 240 MT20 244/190 180 n/a Weight: 25 lb NOTES (6-8) 1) Wind: ASCE 7-98; 120mph (3-second gust); h=15ft; TCDL=5.0psf; BCDL=5.0psf; Category II; Exp B; enclosed; MWFRS interior zone and C-C Interior(1) zone; cantilever left and right exposed ; porch left exposed; Lumber DOL=1.33 plate grip DOL=1.33. This truss is designed for C-C for members and forces , and for MWFRS for reactions specified. 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Refer to girder(s) for truss to truss connections. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 92 lb uplift at joint D, 230 lb uplift at joint B and 73 lb uplift at joint E. 5) "Fix heels only" Member end fixity model was used in the analysis and design of this truss. 6) NOTE: Refer to yellow bracing and/or T-1 sheet for more information. 7) NOTE: The seal on this drawing indicates acceptance of professional engineering responsibility solely for the truss component design shown. 8) NOTE: Trusses are designed for an Enclosed building condition as per building designer, assuming d664'*hd windows are protected from windborne debris impact as per Fla. Bldg. Code 1606.1.4 LOAD CASE(S) Standard R E -t-� GAGAN, P.E. # 2! Joli Truss— Truss Type Q1Y PIY 53107 / METRO DEV/ Sanford Housing / Bc 53107 J210 ROOF TRUSS 1 1 Job Reference (optional) Trussway, Orlando, FI 6.100 a Sep 17 2004 MiTek Industries, Inc. Wed Oct 26 17:00:34 2005 Page 1 _1I -1-2-8 2-10-8 C 1-2-8 2-10-8 ea1e, 1:1.01 4.001 1 2 B T1 B1 I D 2-10-8 — 2108 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.33 Vert(LL) -0.00 B-D >999 240 MT20 244/190 TCDL 10.0 Lumber Increase 1.25 I BC 0.10 Vert(TL) -0.00 B-D >999 180 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(TL) -0.00 C n/a n/a BCDL 10.0 Code FBC2001/ANSI95 (Matrix) Weight: 11 lb LUMBER 4) Provide mechanical connection (by others) of truss TOP CHORD 2 X 4 SYP No.3 to bearing plate capable of withstanding 23 lb uplift at BOT CHORD 2 X 4 SYP No.3 joint C and 118 lb uplift at joint B. 5) "Fix heels only" Member end fixity model was used BRACING in the analysis and design of this truss. TOP CHORD 6) NOTE: Refer to yellow bracing and/or T-1 sheet for Sheathed or 2-10-8 oc purlins. more information. BOT CHORD 7) NOTE: The seal on this drawing indicates Rigid ceiling directly applied or 10-0-0 oc bracing. acceptance of professional engineering responsibility solely for the truss component design REACTIONS (lb/size) shown. C = 46/Mechanical 8) NOTE: Trusses are designed for an Enclosed B = 220/0-8-0 building condition as per building designer, D = 25/Mechanical assuming doors and windows are protected from Max Horz windbome debris impact as per Fla. Bldg. Code B = 59(load case 4) 1606.1.4 Max Uplift C =-23(load case 5) LOAD CASE(S) I B =-118(load case 4) Standard Max Grav C = 46(load case 1) B = 220(load case 1) D = 50(load case 2) FORCES (lb) Maximum Compression/Maximum Tension TOP CHORD A-B = 0/22 B-C = -37111 BOT CHORD B-D = 010 NOTES (6-8) 1) Wind: ASCE 7-98; 120mph (3-second gust); h=15ft; TCDL=5.Opsf; BCDL=5.Opsf; Category II; Exp B; enclosed; MWFRS interior zone and C-C Interior(1) zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33. This truss is designed for C-C for members and forces, and for MWFRS for reactions specified. 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Refer to girder(s) for truss to truss connections. IQBAL H.A. GAGAN P.E. # 26389 Orlando, FL. 32824 MR1f71t10?5 Job I Truss Truss Type Qty Ply 153107 J210A i ROOF TRUSS (1 1 6.100 a Sep 17 2004 MiTek Industries, Inc. LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/defl Ud TCLL 20.0 Plates Increase 1.25 TC 0.15 Vert(LL) -0.00 A-C >999 240 TCDL 10.0 Lumber Increase 1.25 BC 0.10 Vert(TL) -0.00 A-C >999 180 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(TL) -0.00 B n/a n/a BCDL 10.0 Code FBC2001/ANS195 (Matrix) LUMBER TOP CHORD 2 X 4 SYP No.3 BOT CHORD 2 X 4 SYP No.3 BRACING TOP CHORD Sheathed or 2-10-8 oc pudins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) A = 99/0-8-0 B = 74/Mechanical C = 25/Mechanical Max Horz A = 37(load case 4) Max Uplift A = 15(load case 4) B = -42(load case 4) Max Grav A = 99(load case 1) B = 74(load case 1) C = 50(load case 2) FORCES (lb) Maximum Compression/Maximum Tension TOP CHORD A-B = -28/22 BOT CHORD A-C = 0/0 NOTES (6-8) 1) Wind: ASCE 7-98; 120mph (3-second gust); h=15ft; TCDL=S.Opsf; BCDL=S.Opsf; Category II; Exp B; enclosed; MWFRS interior zone and C-C Interior(1) zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33. This truss is designed for C-C for members and forces, and for MWFRS for reactions specified. 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Refer to girder(s) for truss to truss connections. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 15 lb uplift at joint A and 42 lb uplift at joint B. 5) "Fix heels only" Member end fixity model was used in the analysis and design of this truss. 6) NOTE: Refer to yellow bracing and/or T-1 sheet for more information. 7) NOTE: The seal on this drawing indicates acceptance of professional engineering responsibility solely for the truss component design shown. 8) NOTE: Trusses are designed for an Enclosed building condition as per building designer, assuming doors and windows are protected from windborne debris impact as per Fla. Bldg. Code 1606.1.4 LOAD CASE(S) Standard PLATES GRIP MT20 244/190 Weight: 9 lb Scale = 1:7.0! P.E. # MAR 14 NfJ6 53107 IR01 ROOF TRUSS 1 ng Trussway s Sep 17 2004 MiTek 2005 11-2-8 5-5-12 7 0 0 11-8-15 1 16-7-9 1 21-4-7 26-3-2 31_ 0-0 � 2_-6-� 38-M a9-2-8 1-2-8 5-5-12 1-6-4 4-8-15 4-10-10 4-8-14 4-10-10 4-8-15 1-6-4 5-5-12 1-2-8 Scale = 1:67.7 2x4 11 4.00 12 6x7 = 3x7 = 3x10 M1120H = 2X4 " D E F G 3x9 = 3x6 = 3x5 = 6x7 = H 1 .I . 2x4 4x6 = V U T S R Q P 0 47 = 4x5 = 45 = 5x6 = 6x12 = 6x8 = 5x6 = 45 = 4x5 = 7-0-0 11-8-15 16-7-9 16z8-0 21-4-7 26-3-2 31-0-0 + 38-M 7-0-0 4-8-15 4-10-10 0-0-7 4-8-7 4-10-10 4-8-15 7-0-0 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) Vdefl Ud PLATES GRIP TCLL 20.0 Plates Increase 1.. 5 TC 0.98 Vert(LL) 0,17 0-P >999 240 MT20 244/190 TCDL 10.0 Lumber Increase 1.25 BC 0.59 Vert(TL) 0.26 O-P >967 180 M1120H 187/143 BCLL 0.0 Rep Stress Incr NO WB 0.97 Horz(TL) 0.07 M n/a n/a BCDL 10.0 Code FBC2001/ANSI95 (Matrix) Weight: 210lb LUMBER TOP CHORD 2 X 4 SYP No.1 'Except' T1 2 X 4 SYP No.2, T1 2 X 4 SYP No.2 BOT CHORD 2 X 6 SYP No.2 WEBS 2 X 4 SYP No.3 BRACING TOP CHORD Sheathed or 3-1-2 oc purlins. BOT CHORD Rigid ceiling directly applied or 6-10-5 oc bracing WEBS 1 Row at midpt E-S, H-S, J-R REACTIONS (lb/size) S = 4146/0-4-0 M = 1438/0-8-0 B = 906/0-3-0 Max Horz B = -52(load case 6) Max Uplift S = -1730(load case 3) M = -681(load case 4) B = -453(load case 3) Max Grav S = 4146(load case 1) M = 1447(load case 8) B = 918(load case 7) FORCES (lb) Maximum Compression/Maximum Tension TOP CHORD A-B = 0/26 B-C =-2013/804 C-D =-18161753 D-E =-448/190 E-F =-1130/2819 F-G =-1130/2819 G-H =-1130/2819 H-1 =-9301429 W =-930/429 J-K =-300411276 K-L =-3341/1396 L-M =-3506/1433 M-N = 0/26 BOTCHORD B-V =-735/1862 BOT CHORD U-V =-616/1636 T-U =-116/448 S-T =-116/448 Q-R =-1161/300 P-Q =-1161/3004 O-P = 41191/309 M-0 =-1285/3262 R-S = 2322/930 WEBS C-V =-261/148 D-V =-358/888 D-U =-1346/555 E-U =-269/821 E-S =-3539/1457 G-S =-670/335 H-S =-4092/1712 H-R =-442/1189 J-R =-2311/936 J-P =-61/371 K-P =-120/83 K-0 =-328/823 L-0 =-181/116 NOTES (11-13) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-98; 120mph (3-second gust); h=15ft; TCDL=5.Opsf; BCDL=5.Opsf; Category II; Exp B; enclosed; MWFRS interior zone; cantilever left and right exposed ; porch left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33. 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) All plates are MT20 plates unless otherwise indicated. 6) Bearing at joint(s) S considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1730 lb uplift at joint S, 681 lb uplift at joint M and 453 lb uplift at joint B. 8) "Fix heels only" Member end fixity model was used in the analysis and design of this truss. J 1c; 6 9) Special hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 5131b down and 1441b up at 31-0-0, and 5131b down and 1441b up at 7-0-0 on bottom chord. The design/selection of such special connection device(s) is the responsibility of others. 10) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). 11) NOTE: Refer to yellow bracing and/or T-1 sheet for more information. 12) NOTE: The seal on this drawing indicates acceptance of professional engineering responsibility solely for the truss component design shown. 13) NOTE: Trusses are designed for an Enclosed building condition as per building designer, assuming doors and windows are protected from windborne debris impact as per Fla. Bldg. Code 1606.1.4 LOAD CASE(S) Standard 1) Regular: Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: A-D=-60, D-K=-131(F=-71), K-N=-60, B-V=-20 , R-V=-44(F=-24), O-R=-44(F=-24), M-O=-20 Concentrated Loads (lb) Vert: V=-513(F) 0=-513(F) P.E. f# 25389 Orlando, FL. 32824 MaR 14, ZU06 goo 53107 I Truss R01A Truss Type ROOF TRUSS Qty 1 1 Ply 53107 / METRO DEW Sanford Housing / Bc 1 Job Reference (optional) Trussway, Orlando, FI 6.100 s Sep 17 2004 MiTek Industries, Inc. Thu Oct 27 08:46:48 2005 Page 1 7-0-0 11-8-14 1 16-7-9 21-4-7 26-3-2 31-0-0 38-0-0 39-2-8 t1-2-8 1-2-8 7-0-0 4-8-14 4-10-10 4-8-14 4-10-10 4-8-14 7-0-0 1-2-8 Scale = 1:67.7 4,00 12 6x7 = 3x5 = 3x5 = 3x6 = 2x4 11 3x6 = 6x7 zz C D E F G H I i 3 -� �n J B ii �� i 1 i f - i G 0 5x7 = S R Q P O N M L 4x6 = 2x4 1; 5x12 M1120H = 4x9 = 4x6 = 2x4 11 4x6 = 6x6 = 5x12 M1120H = 7-0-0 11-8-14 1 16-7-9 21-4-7 26-3-2 31-0-0 38-0-0 7-0-0 _ 4-8-14 4-10-10 4-8-14 4-10-10 4-8-14 7-0-0 LOADING (psf) I SPACING 2-0-0 CSI DEFL in floc) I/deft Ud PLATES GRIP TCLL 20.0 Plates Increase 1,25 TC 1.00 Vert(ILL) 0.65 O-P >691 240 MT20 244/190 TCDL 10.0 Lumber Increase 1.25 BC 0.99 Vert(TL) -1.29 O-P >348 180 M1120H 187/143 BCLL 0.0 Rep Stress Incr NO WB 0.74 Horz(TL) 0.16 J n/a n/a BCDL 10.0 Code FBC20011ANS195 i (Matrix) I I Weight: 4091b LUMBER TOP CHORD 2 X 4 SYP No.2 BOT CHORD 2 X 6 SYP No.1 WEBS 2 X 4 SYP No.3 BRACING TOP CHORD Sheathed. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except: 9-8-12 oc bracing: P-R 8-11-11 oc bracing: O-P. REACTIONS (lb/size) B = 3472/0-8-0 J = 261610-8-0 Max Horz B = 52(load case 5) Max Uplift B =-939(load case 3) J =-700(load case 4) FORCES (Ib) Maximum Compression/Maximum Tension TOP CHORD A-B = 0126 B-C =-9584/2413 C-D = -13049/3383 D-E =-1529813957 E-F = -13160/3359 F-G =-13160/3359 G-H = -13160/3359 H-1 =-10250/2600 I-J = -6985/1695 J-K = 0/26 BOT CHORD B-S = -2237/8995 R-S =-2232/8951 Q-R = -3309113049 P-0 =-3309/13049 O-P = -3882/15298 N-0 =-2493110250 M-N = -2493/10250 L-M =-1520/6526 J-L = -1517/6536 WEBS C-S = -66/687 C-R =-1218/4620 D-R = -1747/627 D-P =-656/2530 E-P = -1481626 E-O =-2424/675 G-O = -259/121 WEBS H-O =-862/3262 H-M =-1699/518 I-M =-1095/4204 I-L = 0/256 NOTES (13-15) 1) Special hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 15641b down and 4391b up at 16-8-0, and 5131b down and 1441b up at 7-0-0 on bottom chord. The design/selection of such special connection device(s) is the responsibility of others. 2) 2-ply truss to be connected together with 1 Od Common(.148"x3") Nails as follows: Top chords connected as follows: 2 X 4 - 1 row at 0-9-0 oc. Bottom chords connected as follows: 2 X 6 - 2 rows at 0-7-0 oc. Webs connected as follows: 2 X 4 - 1 row at 0-9-0 oc. Special hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 15641b down and 4391b up at 16-8-0, and 5131b down and 1441b up at 7-0-0 on bottom chord. The design/selection of such special connection device(s) is the responsibility of others. 3) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 4) Unbalanced roof live loads have been considered for this design. 5) Wind: ASCE 7-98; 120mph (3-second gust); h=15ft; TCDL=5.Opsf; BCDL=5.Opsf; Category 11; Exp B; enclosed; MWFRS interior zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33. 6) Provide adequate drainage to prevent water ponding. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) All plates are MT20 plates unless otherwise K IC; 6 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 939 lb uplift at joint B and 700 lb uplift at joint J. 10) Girder carries hip end with 7-0-0 end setback. 11) "Fix heels only" Member end fixity model was used in the analysis and design of this truss. 12) Special hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 15641b down and 4391b up at 16-8-0, and 5131b down and 1441b up at 7-0-0 on bottom chord. The design/selection of such special connection device(s) is the responsibility of others. 13) NOTE: Refer to yellow bracing and/or T-1 sheet for more information. 14) NOTE: The seal on this drawing indicates acceptance of professional engineering responsibility solely for the truss component design shown. 15) NOTE: Trusses are designed for an Enclosed building condition as per building designer, assuming doors and windows are protected from windborne debris impact as per Fla. Bldg. Code 1606.1.4 LOAD CASE(S) Standard 1) Regular: Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: A-C=-60, C-E=-125(F=-65), E-I=-60, I-K=-60, B-S=-20, P-S=-42(F=-22), J-P=-20 Concentrated Loads (lb) Vert: S=-513(F) P=-1564(F) tyAGAN. P.E. # 2 MA 1 4 7LT0 Job Truss ;Truss Type oiy �Plr 53107 1 METRO DEV/ Sanford Housing 53107 R02 iROOFTRUSS 1 1 FI 6.100 s Sep 17 2004 2005 Page 11-2-8 5-3-2 9-0-0 15-4-3 22-7-13 + 29-0-0 I 32-8-14 38-0-0 �9- -8 1-2-8 5-3-2 3-8-14 6-4-3 7-3-10 6-4-3 3-8-14 5-3-2 1-2-8 Scale = 1: 4.00 12 6x6 = 3x5 = 3x6 = 49 = 6x6 zz 45 = Q P O N M L 45 = 4x9 = 3x6 = 5x5 = 2x4 // 3x6 = 49 = 9-0-0 LOADING (psf) I SPACING 2 TCLL 20.0 Plates Increase TCDL 10.0 Lumber Increase BCLL 0.0 Rep Stress Incr BCDL 10.0 Code FBC2001/AN LUMBER TOP CHORD 2 X 4 SYP No.2 BOT CHORD 2 X 4 SYP No.2 WEBS 2 X 4 SYP No.3 BRACING TOP CHORD Sheathed or 4-11-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 1 Row at midpt G-O REACTIONS (lb/size) B = 53610-3-0 O = 1868/0-3-8 J = 771/0-8-0 Max Horz B = 59(load case 6) Max Uplift B =-393(load case 4) O =-697(load case 4) J =-218(load case 5) Max Grav B = 560(load case 8) 1 O = 1868(load case 1) J = 790(load case 9) FORCES (lb) Maximum Compression/Maximum Tension TOP CHORD A-B = 0/22 B-C = -88 C-D =-474/685 D-E = -40 E-F =-472/1089 F-G = -47 G-H =-10301237 H-1 = -11 1-J =-1495/364 J-K = 0/22 BOT CHORD B-Q =-774/806 P-Q = -68 O-P =-6831345 N-0 = 0157 M-N = 0/527 L-M = 0/52 J-L =-255/1375 SI95 16-7-9 16P-0 21-4-0 29-0-0 7-7-9 0-0-7 4-8-0 7-8-0 J_ -0-0 CSI DEFL in (loc) I/deft 1.25 TC 0.74 Vert(LL) 0.29 B-Q >691 1.25 BC 0.65 Vert(TL) -0.23 B-Q >864 YES WB 0.85 Horz(TL) 0.03 J n/a :, (Matrix) 4/894 8/662 2/1089 38/225 3/345 3 7 BOT CHORD B-Q =-774/806 P-Q =-683/345 O-P =-683/345 N-O = 0/573 M-N = 0/527 L-M = 0/527 J-L =-255/1375 WEBS C-Q =-444/302 D-Q =-116/42 E-Q =-927/1129 E-O =-10201737 H-L = 0/195 I-L =-376/207 G-N = 01245 G-L =-182/599 G-0 =-1762/561 NOTES (7-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-98; 120mph (3-second gust); h=15ft; TCDL=5.Opsf; BCDL=5.Opsf; Category II; Exp B; enclosed; MWFRS interior zone and C-C Interior(1) zone; cantilever left and right exposed ; porch left exposed; Lumber DOL=1.33 plate grip DOL=1.33. This truss is designed for C-C for members and forces , and for MWFRS for reactions specified. 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 393 lb uplift at joint B, 697 lb uplift at joint O and 218 lb uplift at joint J. 6) "Fix heels only" Member end fixity model was used in the analysis and design of this truss. 38-0-0 9-M Ud PLATES GRIP 240 MT20 244/190 180 n/a Weight: 178 lb u C% r 1M 6 7) NOTE: Refer to yellow bracing and/or T-1 sheet for more information. 8) NOTE: The seal on this drawing indicates acceptance of professional engineering responsibility solely for the truss component design shown. 9) NOTE: Trusses are designed for an Enclosed building condition as per building designer, assuming doors and windows are protected from windborne debris impact as per Fla. Bldg. Code 1606.1.4 LOAD CASE(S) Standard t— GAN, P.E. # M,.2 JOD 1 russ i l russ I ype I aty Ply i 53107 / METRO DEV/ Sanford Housing / Bc '... 53107 R02A ROOF TRUSS 1 1 _ Job Reference (optional) Trussway, Orlando, FI 6.100 s Sep 17 2004 MiTek Industries. Inc. Thu Oct 27 08:46:49 2005 Paae 1 I 1 �l 6 11-2� $_ 5-3-2 9-M 15-4-3 22-7-13 29-0-0 32-8-14 38-0-0 1-2-8 5-3-2 3-8-14 6-4-3 7.3-10 6-4-3 3-8-14 5-3-2 Scale = 1:67.9 4.00112 12 3x5 = 6x6 = 6x6 3x10 M1120H = 4x9 = zz 4x7 = P O N M L K 4x7 = 4x9 = 5x12 M1120H WB = 5x12 M1120H WB = 49 = 3x5 = 2x4 // 9-0-0 16-M + 21-4-0 i 29-0-0 38-M 9-0-0 7-8-0 4-8-0 7-8-0 9-0-0 1M 0 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/defl Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.85 Vert(LL) 1.03 N-P >437 240 MT20 244/190 TCDL 10.0 Lumber Increase 1.25 BC 0.97 Vert(TL) -0.84 M-N >535 180 M1120H 187/143 BCLL 0.0 Rep Stress Incr YES WB 0.57 Horz(TL) -0.25 J n/a n/a BCDL 10.0 Code FBC2001/ANSI95 (Matrix) Weight: 176lb LUMBER TOP CHORD 2 X 4 SYP No.2 'Except' T2 2 X 4 SYP No.1, T3 2 X 4 SYP No.1 BOT CHORD 2 X 4 SYP No.1 *Except* B2 2 X 4 SYP No.2 WEBS 2 X 4 SYP No.3 BRACING TOP CHORD Sheathed or 2-7-5 oc purlins. BOT CHORD Rigid ceiling directly applied or 2.7-5 oc bracing. WEBS 1 Row at midpt E-P, G-K REACTIONS (lb/size) J = 1500/0-8-0 B = 1583/0-3-0 Max Horz B = 65(load case 6) Max Uplift J = -890(load case 5) B = -959(load case 4) FORCES (lb) Maximum Compression/Maximum Tension TOP CHORD A-B = 0/22 B-C =-3957/3583 C-D =-3622/3438 D-E =-3351/3236 E-F =-4581/4388 F-G =-4581/4388 G-H =-3306/3201 H-1 =-3573/3401 I-J =-3856/3506 BOT CHORD B-P =-334613704 O-P =-4162/4534 N-O =-4162/4534 M-N =-4253/4574 L-M =-4156/4524 K-L =-4156/4524 J-K =-326213594 WEBS C-P =-345/214 D-P =-937/882 E-P =-1404/1166 E-N =-239/245 H-K =-926/865 WEBS I-K =-276/176 G-M =-244/252 G-K =-1441/1196 G-N = -81/95 NOTES (8-10) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-98; 120mph (3-second gust); h=15ft; TCDL=5.Opsf; BCDL=5.Opsf; Category 11; Exp B; enclosed; MWFRS interior zone and C-C Interior(1) zone; cantilever left and right exposed ; porch left exposed; Lumber DOL=1.33 plate grip DOL=1.33. This truss is designed for C-C for members and forces , and for MWFRS for reactions specified. 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) All plates are MT20 plates unless otherwise indicated. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 890 lb uplift at joint J and 959 lb uplift at joint B. 7) "Fix heels only" Member end fixity model was used in the analysis and design of this truss. 8) NOTE: Refer to yellow bracing and/or T-1 sheet for more information. 9) NOTE: The seal on this drawing indicates acceptance of professional engineering responsibility solely for the truss component design shown. 10) NOTE: Trusses are designed for an Enclosed building condition as per building designer, assuming doors and windows are protected from windborne debris impact as per Fla. Bldg. Code 1606.1.4 LOAD CASE(S) Standard >? N, P.E. # 2538 I fu55 I ype sty i v1y 1.53107 / METRO DEV/ Sanford Housing / Bc 53107 j R03 !ROOF TRUSS 1 1 Job Reference (optional) j Trussway, Orlando, FI i 6.100 a Sep 17 2004 MiTek Industries, Inc. Thu Oct 27 08:46:50 2005 Page 1 11.2-8 5-0-6 11-0-0 i + 19-0-0 27-M 32-11-10 38-M $9-2-8 1-2-8 5-0-6 5-11-10 8-0-0 8-0-0 5-11.10 5-0-6 1-2-8 Scale = 1:68.0i = 4.00 12 6x7 3x5 = 3x6 6x7 D E F G \ 2x4 wal 2x4 i W,' / �N1 %/ `.W3 H - 4 /7y '' W '1 i J rt �/ Gam- 1M d " 05 = p � O N M L K 4x5 = 3x5 = 3x6 = 5x5 = 3x5 = 3x6 = 3x5 I, 7-5-5 I 16-M 21-4-0 30-6-11 38-0-0 7-5-5 I I 9-2-11 4-8-0 9-2-11 75-5 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/defl Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.90 Vert(LL) 0.34 N-P >587 240 MT20 244/190 TCDL 10.0 Lumber Increase 1.25 BCLL 0.0 Rep Stress Incr YES BCDL 10.0 Code FBC2001/ANSI95 BC 0.66 Vert(TL) 0.27 N-P >730 180 WB 0.66 Horz(TL) 0.02 1 n/a n/a (Matrix) Weight: 174lb i UMBER TOP CHORD 2 X 4 SYP No.2 'Except' BOT CHORD LOAD CASE(S) T2 2 X 4 SYP No.1 B-P =-765/794 O-P =-241/41 Standard BOT CHORD 2 X 4 SYP No.2 N-O =-241/41 M-N =-460/434 WEBS 2 X 4 SYP No.3 L-M = 0/644 K-L = 0/644 I-K =-205/1388 BRACING WEBS TOP CHORD C-P =-479/299 D-P =-710/639 ! Sheathed or 4-10-1 oc purlins. D-N =-1238/879 E-N =-1374/528 BOT CHORD E-M =-83/660 G-M =-778/374 Rigid ceiling directly applied or 6-0-0 oc bracing. G-K =-74/608 H-K =-425/265 WEBS 1 Row at midpt D-N NOTES (7-9) 1) Unbalanced roof live loads have been considered REACTIONS (lb/size) for this design. B = 474/0-3.0 2) Wind: ASCE 7-98; 120mph (3-second gust); N = 1979/0-4-0 h=15ft; TCDL=5.Opsf; BCDL=5.Opsf; Category II; Exp 1 = 723/0-8-0 B; enclosed; MWFRS interior zone and C-C Interior(1) Max Horz zone; cantilever left and right exposed ; porch left B =-68(load case 7) exposed; Lumber DOL=1.33 plate grip DOL=1.33. ' Max Uplift This truss is designed for C-C for members and forces B =-376(load case 6) , and for MWFRS for reactions specified. N =-727(load case 4) 3) Provide adequate drainage to prevent water 1 =-201(load case 5) ponding Max Grav 4) This truss has been designed for a 10.0 psf bottom B = 518(load case 8) chord live load nonconcurrent with any other live N = 1979(load case 1) loads. I = 758(load case 9) 5) Provide mechanical connection (by others) of truss i to bearing plate capable of withstanding 376 lb uplift FORCES (lb) at joint B, 727 lb uplift at joint N and 201 lb uplift at Maximum Compression/Maximum Tension joint 1. TOP CHORD 6) "Fix heels only" Member end fixity model was used A-B = 0/22 B-C =-865/884 in the analysis and design of this truss. C-D =-484/715 D-E =-521/1192 7) NOTE: Refer to yellow bracing and/or T-1 sheet for E-F =-195/108 F-G =-1951108 more information. G-H =-1158/155 H-1 =-1512/293 8) NOTE: The seal on this drawing indicates I-J = 0/22 acceptance of professional engineering BOT CHORD responsibility solely for the truss component design i B-P =-765/794 O-P =-241/41 shown.' N-0 =-241/41 M-N =-460/434 9) NOTE: Trusses are designed for an Enclosed L-M = 0/644 K-L = 0/644 building condition as per building designer, 1-K =-205/1388 assuming doors and windows are protected from windborne debris impact as per Fla. Bldg. Code IQBAL H.A. GAGAN P.E. # 25389 1 ���0r;ando,r FL. 32324 QI M Job Truss Truss Type oty Pb ,;53107 / METRO DEV/ Sanford Housing / Bc 153107 j R03A ROOF TRUSS 1 1 Job Reference (optional) j I Trussway, Orlando, FI 6,100 s Sep 17 2004 MiTek Industries, Inc. Thu Oct 27 08:46:50 2005 Paae 1 I .4 o 11-2-$ 5-0-6 11-0-0 19-0-0 21.4-4 27-M 32-11-10 38-0-0 1-2-8 5-0-6 5-11-10 8-0-0 2-4-4 5-7-13 5-11-10 5-0-6 Scale = 1:67.8 i 6x7 = 6x7 = 4.00 (12 3x5 = 3x6 = D E F G 4x7 = O N M L K J 4x7 = 3x5 = 3x10 M1120H = 3x5 = 3x5 = 3x5 = 3x10 M1120H = 7-5-5 6-6-11 16-M 21-4-0 24-0-0 30-6-11 38-0-( 2-8-0 4-8-0 2-8-0 6-6-11 7-5-5 LOADING (psf) SPACING 2-0-0 I CSI DEFL in (loc) Vdefl Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.97 Vert(LL) 0.36 L-M >999 240 MT20 244/190 TCDL 10.0 Lumber Increase 1.25 BC 0.96 Vert(TL) -0.73 M-O >617 180 M1120H 187/143 BCLL 0.0 Rep Stress Incr YES WB 0.29 ( Horz(TL) 0.18 1 n/a n/a BCDL 10.0 Code FBC2001/ANSI95 i (Matrix) I Weight: 172lb LUMBER NOTES (8-10) TOP CHORD 2 X 4 SYP No.2 'Except' 1) Unbalanced roof live loads have been considered T2 2 X 4 SYP SS, T3 2 X 4 SYP SS for this design. BOT CHORD 2 X 4 SYP No-2 2) Wind: ASCE 7-98; 120mph (3-second gust); WEBS 2 X 4 SYP No.3 h=15ft; TCDL=5.Opsf; BCDL=5.Opsf; Category 11; Exp B; enclosed; MWFRS interior zone and C-C Interior(1) BRACING zone; cantilever left and right exposed ; Lumber TOP CHORD DOL=1.33 plate grip DOL=1.33. This truss is Sheathed. designed for C-C for members and forces, and for BOT CHORD MWFRS for reactions specified. Rigid ceiling directly applied or 5-8-9 oc bracing. 3) Provide adequate drainage to prevent water ponding. REACTIONS (lb/size) 4) This truss has been designed for a 10.0 psf bottom 1 = 1491/0-8-0 chord live load nonconcurrent with any other live B = 1588/0-8-0 loads. Max Horz 5) All plates are MT20 plates unless otherwise B = 74(load case 6) indicated. Max Uplift 6) Provide mechanical connection (by others) of truss I =-323(load case 5) to bearing plate capable of withstanding 323 lb uplift B =-402(load case 4) at joint I and 402 lb uplift at joint B. 7) "Fix heels only" Member end fixity model was used FORCES (lb) in the analysis and design of this truss. Maximum Compression/Maximum Tension 8) NOTE: Refer to yellow bracing and/or T-1 sheet for TOP CHORD more information. A-B = 0/22 B-C =-3904/1222 9) NOTE: The seal on this drawing indicates C-D =-3616/1099 D-E =-3699/1241 acceptance of professional engineering E-F =-3701/1244 F-G =-3701/1244 responsibility solely for the truss component design G-H =-3639/1136 H-1 =-3927/1271 shown. BOT CHORD 10) NOTE: Trusses are designed for an Enclosed B-O =-1105/3633 N-0 =-893/3034 building condition as per building designer, M-N =-893/3034 L-M =-1200/3885 assuming doors and windows are protected from K-L =-907/3043 J-K =-907/3043 windborne debris impact as per Fla. Bldg. Code 1-J =-1157/3667 1606.1.4 WEBS C-0 =-324/226 D-0 =-35/544 LOAD CASE(S) D-M =-225/902 E-M =-421/221 E-L =-419/217 G-L =-212/896 Standard G-J =-60/550 H-J =-337/247 goo ; truss Truss Type IQty IPly 153107 / METRO DEV/ Sanford Housing / Bc 53107 R04 ! ROOF TRUSS 1 1 Job Reference (optional) Trussway, Orlando, FI 6.100 a Sep 17 2004 MiTek Industries, Inc. Thu Oct 27 08:46:51 2005 Page 1 11-2-8 5-7-1 13-0-0 19-0-0 25-0-0 32 4-15 38-0-0 39-22--8 1-2-8 5-7-1 7-4-15 6-0-0 6-M 7-4-15 5-7-1 1-2-8 Scale = 1:68.0I 6x7 3x5 = 6x7 = 4.00;12 D E F 2x4 /.:' `\ , / \ VU2 W Y W 1 W� �3 2x4 C= �/ j i, G \ al Ln B /� y h \` t� i R2 / i H �A� I� � 4x5 = O N M L K o J 4x5 = 3x5 = 3x6 = 6x6 = 3x5 6x6 = 3x6 = 7-4-13 15-1-9 155---3 22-9-13 30-7-3 — I 38-0-0 —� 7-4-13 7-8-12 0-0-10 7-7-9 7-9-6 74-13 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.72 Vert(LL) 0.19 M-O >974 240 MT20 244/190 TCDL 10.0 Lumber Increase 1.25 BC 0.53 Vert(TL) 0.16 M-O >999 180 BCLL 0.0 Rep Stress Incr YES WB 0.86 Horz(TL) 0.01 H n/a n/a BCDL 10.0 Code FBC2001/ANS195 (Matrix) i Weight: 178lb LUMBER TOP CHORD 2 X 4 SYP No.2 WEBS BOT CHORD 2 X 4 SYP No.2 F-L =-492/270 F-J =-199/772 WEBS 2 X 4 SYP No.3 G-J = 472/294 BRACING NOTES (7-9) TOP CHORD 1) Unbalanced roof live loads have been considered Sheathed or 3-11-15 oc purlins. for this design. BOT CHORD 2) Wind: ASCE 7-98; 120mph (3-second gust); Rigid ceiling directly applied or 6-0-0 oc bracing. h=15ft; TCDL=5.Opsf; BCDL=5.Opsf; Category 11; Exp B; enclosed; MWFRS interior zone and C-C Interior(1) REACTIONS (lb/size) zone; cantilever left and right exposed ; porch left B = 340/0-3-0 exposed; Lumber DOL=1.33 plate grip DOL=1.33. M = 2072/0-3-8 This truss is designed for C-C for members and forces H = 764/0-8-0 , and for MWFRS for reactions specified. Max Horz 3) Provide adequate drainage to prevent water B --78(load case 7) ponding. Max Uplift 4) This truss has been designed for a 10.0 psf bottom B =-329(load case 6) chord live load nonconcurrent with any other live M =-721(load case 4) loads. H =-211(load case 5) 5) Provide mechanical connection (by others) of truss Max Grav to bearing plate capable of withstanding 329 lb uplift B = 409(load case 8) at joint B, 721 lb uplift at joint M and 211 lb uplift at M = 2072(load case 1) joint H. H = 808(load case 9) 6) "Fix heels only" Member end fixity model was used in the analysis and design of this truss. FORCES (lb) 7) NOTE: Refer to yellow bracing and/or T-1 sheet for Maximum Compression/Maximum Tension more information. TOP CHORD 8) NOTE: The seal on this drawing indicates A-B = 0/22 B-C =-519/601 acceptance of professional engineering i C-D =-184/470 D-E =-521/1200 responsibility solely for the truss component design E-F =-386/34 F-G =-1336/226 shown. G-H =-1645/335 H-1 = 0/22 9) NOTE: Trusses are designed for an Enclosed BOT CHORD building condition as per building designer, B-O =-497/470 N-0 =-766/449 assuming doors and windows are protected from M-N =-766/449 L-M =-286/376 windborne debris impact as per Fla. Bldg. Code K-L = 0/583 J-K = 0/583 1606.1.4 H-J =-243/1526 WEBS LOAD CASE(S) C-O =-523/329 D-O =-898/839 Standard D-M =-970/660 E-M =-1390/560 E-L =-185/791 IQSAL H.A. C A � .E'er' %f 25:339 i 8850 T rus ,,, f ouievard Orlando, .32324 M AD, 1 r 53107 R04A ROOF TRUSS 1 1 s Sep 17 2004 MiTek Industries, Inc. Thu Oct 27 1-2-� 5-7-1 13-0-0 19-0-0 25-0-0 32-4-15 38-0-0 1-2-8 5-7-1 7-4-15 6-0-0 6-M 7-4-15 5-7-1 Scale = 1:67.E 6x7 = 3x5 = 6x7 = d nn 119 L� 0 4x7 = N M L K J I 4x7 = 3x5 3x6 = 3x5 = 3x5 = 3x5 = 3x6 = 7-4-13 15-2-3 22-9-13 30-7-3 38-0-0 7-4-13 7-9-6 7-7-10 7-9-6 7-4-13 LOADING (psf) SPACING 2-0-0 TCLL 20.0 Plates Increase 1.25 TCDL 10.0 Lumber Increase 1.25 BCLL 0.0 Rep Stress Incr YES BCDL 10.0 Code FBC2001/ANSI95 CSI TC 0.95 BC 0.83 WB 0.25 (Matrix) DEFL in (loc) I/deft Vert(LL) 0.30 K >999 Vert(TL) -0.57 K-L >786 Horz(TL) 0.17 H n/a Ud 240 180 n/a PLATES GRIP MT20 2441190 Weight: 176 lb LUMBER NOTES (7-9) - TOP CHORD 2 X 4 SYP SS 'Except' 1) Unbalanced roof live loads have been considered T2 2 X 4 SYP No.2 for this design. BOT CHORD 2 X 4 SYP No.2 2) Wind: ASCE 7-98; 120mph (3-second gust); WEBS 2 X 4 SYP No.3 h=15ft; TCDL=5.Opsf; BCDL=5.Opsf; Category 11; Exp B; enclosed; MWFRS interior zone and C-C Interior(1) BRACING zone; cantilever left and right exposed ; Lumber TOP CHORD DOL=1.33 plate grip DOL=1.33. This truss is Sheathed. designed for C-C for members and forces, and for BOT CHORD MWFRS for reactions specified. Rigid ceiling directly applied or 5-10-2 oc bracing. 3) Provide adequate drainage to prevent water REACTIONS (lb/size) ponding. 4) This truss has been designed for a 10.0 psf bottom H = 1491/0-8-0 chord live load nonconcurrent with any other live B = 1588/0-8-0 loads. Max Horz 5) Provide mechanical connection (by others) of truss B = 84(load case 6) to bearing plate capable of withstanding 316 lb uplift Max Uplift at joint H and 395 lb uplift at joint B. H =-316(load case 5) 6) "Fix heels only" Member end fixity model was used B =-395(load case 4) in the analysis and design of this truss. FORCES (lb) 7) NOTE: Refer to yellow bracing and/or T-1 sheet for more information. Maximum Compression/Maximum Tension 8) NOTE: The seal on this drawing indicates TOP CHORD acceptance of professional engineering A-B = 0/22 B-C =-3915/1219 responsibility solely for the truss component design C-D =-3641/1118 D-E =-3034/1013 shown. E-F =-3037/1018 F-G =-3665/1156 9) NOTE: Trusses are designed for an Enclosed G-H =-394411264 building condition as per building designer, BOT CHORD assuming doors and windows are protected from B-N =-1103/3659 M-N =-791/2843 windborne debris impact as per Fla. Bldg. Code L-M =-791/2843 K-L =-949/3228 1606.1.4 J-K =-800/2849 1-1 =-800/2849 H-1 =-1150/3690 LOAD CASE(S) WEBS Standard C-N =-401/265 D-N =-152/684 D-L =-76/519 E-L =-408/187 E-K =-405/181 F-K =-67/516 F-1 =-186/706 G-I =-411/281 — IQSAL H.A. GAGAN, P.E. # 25389 MAD -Job Truss -FP-1y 53107 _7 METRO DEV/ Sanford Housing Bc ' 53107 R05 ROOF TRUSS Job Reference (optional) Trussway, Orlando, FI 6.100 e Sep 17 2004 MiTek Industries, Inc. Thu Oct 27 08:46:52 2005 Page 1 8-3-7 15-0-0 23-M i 29-8-9 38-M. 1-2-8 8-3-7 6-8-9 8-0-0 6-8-9 8-3-7 1-2-8 Scale = 1:68.0 4.00 15-2 6x7 6x7 E F 3x5 3x6 3x6 3x5 D C G H 1 W,1 VV2 74 3 W 114 U1. ur) A B J C? = Q 045 P 0 N M L K 45 2x4 3x6 = 3x5 = 5x5 = 2x4 5x5 = 3x6 k 6-11-3 L 12-10-12 "_0 24-7-7 31-0-13 38-0-0 6-11-3 5-11-9 -1 I 6-1-4 5-7-7 6-5-6 6-11-3 LOADING (psf) SPACING 2-0-0 CS1 DEFIL in (loc) I/defl Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.91 Vert(LL) 0.15 B-Q >999 240 MT20 244/190 TCDL 10.0 Lumber Increase 1.25 BC 0.54 V JQ -0.17 I-K >999 180 BCLL 0.0 Rep Stress Incr YES WB 0.79 Horz(TL) 0.02 1 n/a n/a BCDL 10.0 Code FBC2001/ANS195 (Matrix) Weight: 178 lb LUMBER TOP CHORD 2 X 4 SYP No.2 WEBS BOT CHORD 2 X 4 SYP No.2 E-N = -251/967 F-N = -828/351 WEBS 2 X 4 SYP No.3 F-L = -109/530 H-L = -809/333 H-K = 0/325 BRACING TOP CHORD NOTES (7-9) Sheathed or 3-11-6 oc purlins. 1) Unbalanced roof live loads have been considered BOT CHORD for this design. Rigid ceiling directly applied or 6-0-0 oc bracing. 2) Wind: ASCE 7-98; 120mph (3-second gust); h=15ft; TCDL=5.Opsf; BCDL=5.Opsf; Category 11; Exp REACTIONS (lb/size) B; enclosed: MWFRS interior zone and C-C Interior(l) B = 276/0-3-0 zone; cantilever left and right exposed ; porch left P = 2018/0-5-11 exposed; Lumber DOL=1.33 plate grip DOL=1.33. 1 = 882/0-8-0 This truss is designed for C-C for members and forces Max Horz , and for MWFRS for reactions specified. B =-87(load case 7) 3) Provide adequate drainage to prevent water Max Uplift ponding. B =-298(load case 6) 4) This truss has been designed for a 10.0 psf bottom IP =-650(load case 4) chord live load nonconcurrent with any other live I =-245(load case 5) loads. Max Grav 5) Provide mechanical connection (by others) of truss B = 357(load case 8) to bearing plate capable of withstanding 298 lb uplift P = 2018(load case 1) at joint B, 650 lb uplift at joint P and 245 lb uplift at 1 = 9 11 (load case 9) joint I. 6) "Fix heels only" Member end fixity model was used FORCES (lb) in the analysis and design of this truss. Maximum Compression/Maximum Tension 7) NOTE: Refer to yellow bracing and/or T-1 sheet for TOP CHORD more information. A-B = 0/22 B-C = -150/442 8) NOTE: The seal on this drawing indicates C-D = -436/1006 D-E = -423/1108 acceptance of professional engineering E-F = -168/23 F-G = -867/202 responsibility solely for the truss component design G-H = -947/185 H-i = -1783/357 shown. I-i = 0/22 9) NOTE: Trusses are designed for an Enclosed BOT CHORD building condition as per building designer, B-Q = -389/75 P-Q = -469/43 assuming doors and windows are protected from O-P = -542/439 N-0 = -542/439 windbome debris impact as per Fla. Bldg. Code M-N = 0/660 L-M = 0/660 1606.1.4 K-L = -261/1529 I-K = -230/1615 WEBS LOAD CASE(S) C-Q = -348/336 C-P = -876/762 Standard E-P = -1557/588 103AL H.A. GAG AN, P.E. .4 25339 1 8850 Trusvvvaw BoWevard i Orlan 4P—EL =24�1 1Job ;Truss ;Truss Type ioty Ply '53107 / METRO DEV/ Sanford Housing / Bc 53107 R05A j ROOF TRUSS 11 1 j iJob Reference (optional) T ay, Orlando, FI 6.100 s Sep 17 2004 MiTek Industries, Inc. Thu Oct 27 08:46:52 2065 Page 1 I 1-2-8 8-3-7 15-0-0 23-0-0 29-8-9 38-0-0 1-2-8 8-3-7 6-8-9 8-M 6-8-9 8-3-7 Scale = 1:67.9 I 4.00 , 12 6x7 = 2x4 11 6x7 Zz E F G 3x5 3x6 3x6 H WW"V3kr,/ <:�:::-- W W\Gy5 Ln B A o �! T jM 4x7 = Q 0 P O N M L K 4x7 = 2x4 /i 3x6 = 4x9 = 3x5 = 2x4 \N 3x5 = 3x6 = 6-11-3 13-1-9 130-9 19-0-0 24-7-7 24-410-7 31-0-13 � 38-0-0 6-11-3 6-2-7 1 0-3-0 5-7-7 5-7-7 0-3-0 6-2-7 6-11-3 Plate Offsets X Y : B:0-2-2 0-0-2 [J:0-1-14,0-0-2) LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) 1/defl Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 1.00 Vert(LL) 0.29 N >999 240 MT20 244/190 TCDL 10.0 Lumber Increase 1.25 BC 0.94 Vert(TL) -0.54 L-N >834 180 BCLL 0.0 Rep Stress Incr YES WB 0.49 Horz(TL) 0.17 J n/a n/a ` BCDL 10.0 Code FBC2001/ANSI95 I (Matrix) Weight: 183 lb LUMBER NOTES (7-9) TOP CHORD 2 X 4 SYP No.2 'Except' 1) Unbalanced roof live loads have been considered T4 2 X 4 SYP No.1 for this design. BOT CHORD 2 X 4 SYP No.2 2) Wind: ASCE 7-98; 120mph (3-second gust); i WEBS 2 X 4 SYP No.3 h=15ft; TCDL=5.Opsf; BCDL=5.Opsf; Category 11; Exp B; enclosed; MWFR5 interior zone and C-C Interior(1) BRACING zone; cantilever left and right exposed ; Lumber TOP CHORD DOL=1.33 plate grip DOL=1.33. This truss is Sheathed. designed for C-C for members and forces, and for BOT CHORD MWFRS for reactions specified. Rigid ceiling directly applied or 6-0-14 oc bracing. 3) Provide adequate drainage to prevent water ponding. REACTIONS (lb/size) 4) This truss has been designed for a 10.0 psf bottom B = 158810-8-0 chord live load nonconcurrent with any other live J = 1491/0-8-0 loads. Max Horz 5) Provide mechanical connection (by others) of truss j B = 93(load case 6) to bearing plate capable of withstanding 387 lb uplift Max Uplift at joint B and 308 lb uplift at joint J. B =-387(load case 4) 6) "Fix heels only" Member end fixity model was used J _-308(load case 5) in the analysis and design of this truss. 7) NOTE: Refer to yellow bracing and/or T-1 sheet for FORCES (lb) more information. Maximum Compression/Maximum Tension 8) NOTE: The seal on this drawing indicates TOP CHORD acceptance of professional engineering A-B = 0/22 B-C =-3805/1094 responsibility solely for the truss component design C-D =-3016/937 D-E =-2937/954 shown. E-F =-27891961 F-G =-2789/961 9) NOTE: Trusses are designed for an Enclosed I G-H =-2942/962 H-1 =-3021/945 building condition as per building designer, 1-J =-383011133 assuming doors and windows are protected from i BOT CHORD windborne debris impact as per Fla. Bldg. Code B-Q =-961/3522 P-Q =-994/3441 1606.1.4 O-P =-691/2631 N-0 =-691/2631 M-N =-695/2633 L-M =-695/2633 LOAD CASE(S) K-L =-1026/3462 J-K =-1000/3547 Standard WEBS C-Q = 01316 C-P =-757/313 E-P =-95/510 E-N =-95/400 G-N =-92/397 G-L =-1051516 I-L =-776/341 I-K = 0/319 '2-5� =-2-8--8-/182 A GNA, A, F,E.� #- (Q313- 819 8350 trussa-1 Coulvard —F--N- ----_---- Orlando,.F11,. 328-4 1 - — --- ----- Job ;Truss Truss Type ,Qty Ply 53107 / METRO DEV/ Sanford Housing / Bc 153107 R06 ' ROOF TRUSS 1 1 _ 1 Job Reference (optional Trussway, Orlando, FI 6.100 a Sep 17 2004 MiTek Industries, Inc. Thu Oct 27 08:46:53 2005 Page 1 1-2-8 5-1-6 11-4-0 17-0-0 j 21-0-0 26-8-0 32-10-10 38-0-0 39-2-8 1-2-8 5-1-6 6-2-10 5-8-0 4-0-0 5-8-0 6-2-10 5-1-6 1-2-8 Scale = 1:68.0 4.00 F12 6x7 = 6x7 = F G 3x6 2x4 If l \ 2x4 11 E �� \\ /� H 3x6 1 vul7/ 3x5 pJ// Jjl w2 I 3x5 W _ I� W4 �, ; / / W4 O 4x5 = S o R Q P O N M 05 = 2x4 II 09 = 3x6 = 3x5 = 3x6 = 4x9 = 2x4 II 5-1-6 11-1-9 19-0-0 26-10-7 32-5-3 38-0-0 5-1-6 6-0-3 7-10-7 7-10-7 5-6-13 I 5-6-13 LOADING (psf) I SPACING 2-0-0 CSI DEFL in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.62 Vert(LL) -0.10 M-N >999 240 MT20 244/190 TCDL 10.0 Lumber Increase 1.25 BC 0.60 Vert(TL) -0.21 N-P >999 180 BCLL 0.0 Rep Stress Incr YES WB 0.83 Horz(TL) 0.04 K n/a n/a BCDL 10.0 Code FBC2001/ANS195 (Matrix) Weight: 193lb LUMBER TOP CHORD 2 X 4 SYP No.2 BOT CHORD LOAD CASE(S) BOT CHORD 2 X 4 SYP No.2 K-M =-429/2072 Standard WEBS 2 X 4 SYP No.3 WEBS C-S =-237/213 C-R =-744/727 BRACING E-R =-422/267 F-R-1683/522 TOP CHORD F-P =-141/682 G-P =-511/245 Sheathed or 4-0-11 oc purlins. G-N =-366/1058 H-N =-421/265 BOT CHORD J-N =-606/194 J-M = 0/205 Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS NOTES (7-9) 1 Row at midpt F-R 1) Unbalanced roof live loads have been considered for this design. REACTIONS (lb/size) 2) Wind: ASCE 7-98; 120mph (3-second gust); B = 201/0-8-0 h=15ft; TCDL=5.Opsf; BCDL=5.Opsf; Category II; Exp R = 1948/0-5-11 B; enclosed; MWFRS interior zone and C-C Interior(1) K = 102310-8-0 zone; cantilever left and right exposed ; porch left Max Horz exposed; Lumber DOL=1.33 plate grip DOL=1.33. B =-97(load case 7) This truss is designed for C-C for members and forces Max Uplift , and for MWFRS for reactions specified. B =-247(load case 6) 3) Provide adequate drainage to prevent water R =-586(load case 4) ponding. K =-272(load case 5) 4) This truss has been designed for a 10.0 psf bottom Max Grav chord live load nonconcurrent with any other live B = 289(load case 8) loads. R = 1948(load case 1) 5) Provide mechanical connection (by others) of truss K = 1023(load case 1) to bearing plate capable of withstanding 247 lb uplift I at joint B, 586 lb uplift at joint R and 272 lb uplift at FORCES (lb) joint K. Maximum Compression/Maximum Tension 6) "Fix heels only" Member end fixity model was used TOP CHORD in the analysis and design of this truss. A-B = 0/22 B-C =-1311397 7) NOTE: Refer to yellow bracing and/or T-1 sheet for C-D =-400/912 D-E =-383/982 more information. E-F =-282/923 F-G =-586/196 8) NOTE: The seal on this drawing indicates G-H =-1663/541 H-1 =-1571/427 acceptance of professional engineering I-J =-1625/415 J-K =-2249/544 responsibility solely for the truss component design K-L = 0/22 shown. BOT CHORD 9) NOTE: Trusses are designed for an Enclosed B-S =-355/83 R-S =-355/83 building condition as per building designer, Q-R = 0/361 P-Q = 0/361 assuming doors and windows are protected from O-P = 0/755 N-O = 0/755 windbome debris impact as per Fla. Bldg. Code IQBAL H.A. GA N P.E, # 25389 1 M-N =-429/2072 111 1606.1.4 8850 Tr0Z: V�y boulevard Orlando, FL. 32824 53107 / METRO DEV/ 53107 1 R06A I ROOF TRUSS 11 1 1 e 5ep 17 2004 MiTek Industries, Inc. Thu Oct 27 08:46:53 0-2-8 5-1-6 11-4-0 + 17-M 21-0-0 26-8-0 32-10-10 38-0-0 39-2-8 1-2-8 5-1-6 6-2-10 5-8-0 4-0-0 5-8-0 6-2-10 5-1-6 1-2-8 Scale = 1:67.9 4.0011,12 6x7 = 6x7 = F G 4x7 = S R Q P O N M 4x7 = 2x4 11 4x9 = 3x6 = 3x5 = 3x6 = 4x9 = 2x4 11 5-1-6 11-1-9 19-0-0 26-10-7 32-5-3 38-0-0 I 5-1-6 6-0-3 7-10-7 7-10-7 5-6-13 5-6-13 Plate Offsets (X,Y): [B:0-2-2 0-0-2] [K:0-2-2,0-0-2] LOADING (psf) SPACING 2-M ! CSI DEFL in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.58 Vert(LL) 0.27 P >999 240 i MT20 244/190 TCDL 10.0 Lumber Increase 1.25 BC 0.81 Vert(TL) -0.56 P-R >800 180 BCLL 0.0 Rep Stress Incr YES WB 0.41 Horz(TL) 0.16 K n/a n/a BCDL 10.0 I Code FBC2001/ANS195 (Matrix) Weight: 193lb LUMBER TOP CHORD 2 X 4 SYP No.2 BOT CHORD 2 X 4 SYP No.2 WEBS 2 X 4 SYP No.3 BRACING TOP CHORD Sheathed or 2-11-10 oc purlins. BOT CHORD Rigid ceiling directly applied or 6-5.15 oc bracing REACTIONS (lb/size) B = 158610-8-0 K = 1586/0-8-0 Max Horz B =-97(load case 7) Max Uplift B =-378(load case 4) K =-378(load case 5) FORCES (lb) Maximum Compression/Maximum Tension TOP CHORD A-B = 0/22 B-C =-3871/1083 C-D =-33351981 D-E =-32821993 E-F =-3375/1108 F-G =-2432/812 G-H =-3375/1108 H-1 =-3282/993 I-J =-3335/981 J-K =-3871/1083 K-L = 0/22 BOT CHORD B-S =-936/3596 R-S =-936/3596 Q-R =-545/2402 P-Q =-545/2402 O-P =-545/2402 N-O =-545/2402 M-N =-936/3596 K-M =-936/3596 WEBS C-S = 0/198 C-R =-529/162 E-R =-424/266 F-R =-350/1033 F-P =-68/244 G-P =-681244 G-N =-350/1033 H-N =-424/266 J-N =-529/162 J-M = 0/198 NOTES (7-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-98; 120mph (3-second gust); h=15ft; TCDL=5.Opsf; BCDL=5.Opsf; Category II; Exp B; enclosed; MWFRS interior zone and C-C Interior(1) zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33. This truss is designed for C-C for members and forces, and for MWFRS for reactions specified. 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 378 lb uplift at joint B and 378 lb uplift at joint K. 6) "Fix heels only" Member end fixity model was used in the analysis and design of this truss. 7) NOTE: Refer to yellow bracing and/or T-1 sheet for more information. 8) NOTE: The seal on this drawing indicates acceptance of professional engineering responsibility solely for the truss component design shown. 9) NOTE: Trusses are designed for an Enclosed building condition as per building designer, assuming doors and windows are protected from windborne debris impact as per Fla. Bldg. Code 1606.1.4 LOAD CASE(S) Standard GAGAN P.E. # 25389 tswrav boulevard Job jTruss Truss Type Qtr 'Ply 153107 / METRO DEV/ Sanford Housing / Bc� 53107 R07 ROOF TRUSS 1 1 Job Reference (optional) Trussway, Orlando, FI 6.100 a Sep 17 2004 MiTek Industries, Inc. Wed Oct 26 17.00:41 2005 Page 1 1-2•$ 5-9 3 13-4-2 19-M 24-7-14 32-2-13 38-0-0 39-2- 1-2-8 5-9-3 7-6-15 5-7-14 5-7-14 7-6-15 5-9-3 1-2-8 I Scale = 1:66.6 6x6 = I 4,00 12 F 3x5 5- 3x5 i G 3x6 ; i 3x6 2x4 p C i; �\ \W3 W ! \\\ \ 5 / W6 H 2x4 I . K o L. 1 4x7 = P O N M L 4x7 = 3x5 = 3x10 M1120H = 49 = 3x10 M1120H = 3x5 = 9-1-14 19-0-0 28-10-2 38-M 9-1-14 9-10-2 9-10-2 9-1-14 Plate Offsets X Y ; B:0-2-2 0-0-2 J:0-2-2 0-0-2 LOADING (psf) SPACING 2-0-0 CSI j DEFL in (loc) Vdefl Ud PLATES GRIP TCLL 20.0 Plates Increase 1,25 TC 0.87 Vert(LL) 0.28 L-N >999 240 MT20 244/190 TCDL 10.0 Lumber Increase 1.25 I BC 0.98 Vert(TL) -0.61 L-N >731 180 M1120H 187/143 BCLL 0.0 Rep Stress Incr YES WB 0.77 Horz(TL) 0.16 J n/a n/a BCDL 10.0 Code FBC2001/ANSI95 (Matrix) Weight: 179lb LUMBER NOTES (7-9) TOP CHORD 2 X 4 SYP No.2 1) Unbalanced roof live loads have been considered BOT CHORD 2 X 4 SYP No.1 *Except* for this design. B3 2 X 4 SYP No.2 2) Wind: ASCE 7-98; 120mph (3-second gust); WEBS 2 X 4 SYP No.3 h=15ft; TCDL=5.Opsf; BCDL=5.Opsf; Category II; Exp B; enclosed; MWFRS interior zone and C-C Interior(1) BRACING zone; cantilever left and right exposed ; Lumber TOP CHORD DOL=1.33 plate grip DOL=1.33. This truss is i Sheathed or 2-4-4 oc purlins. designed for C-C for members and forces, and for BOT CHORD MWFRS for reactions specified. Rigid ceiling directly applied or 6-6-1 oc bracing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live REACTIONS (lb/size) loads. B = 1586/0-8-0 4) All plates are MT20 plates unless otherwise J = 1586/0-M indicated. Max Horz 5) Provide mechanical connection (by others) of truss B =-106(load case 7) to bearing plate capable of withstanding 368 lb uplift Max Uplift at joint B and 368 lb uplift at joint J. B =-368(load case 4) 6) "Fix heels only" Member end fixity model was used J =-368(load case 5) in the analysis and design of this truss. 7) NOTE: Refer to yellow bracing and/or T-1 sheet for FORCES (lb) more information. Maximum Compression/Maximum Tension 8) NOTE: The seal on this drawing indicates TOP CHORD acceptance of professional engineering i A-B = 0/22 B-C =-3847/1126 responsibility solely for the truss component design C-D =-3462/943 D-E =-3391/961 shown. E-F =-23951753 F-G =-2395/753 9) NOTE: Trusses are designed for an Enclosed G-H =-3391/961 H-1 =-3462/943 building condition as per building designer, I-J =-3847/1126 J-K = 0/22 assuming doors and windows are protected from BOT CHORD windbome debris impact as per Fla. Bldg. Code B-P =-974/3591 O-P =-705/2854 1606.1.4 N-O =-705/2854 M-N =-705/2854 L-M =-705/2854 J-L =-97413591 LOAD CASE(S) WEBS Standard C-P =-444/277 E-P =-34/610 E-N =-834/353 F-N =-344/1231 G-N =-834/353 G-L =-34/610 I-L =-4441277 IQSAL H.A. GTCANI fa 8350 Truosw— , �t;isvard Orlas sdo, . 32824 Ma;"� t �. ZUIC5 Job iTruss i7russType Oty Ply 153107 / METRO DEV/ Sanford Housing / Bc 53107 R20 ROOF TRUSS 1 1 Job Reference (optional) Trussway, Orlando, FI 6.100 a Sep 17 2004 MiTek Industries, Inc. Wed Oct 26 17:00:42 2005 Page 1 i ! -1-2-8 4-2-5 7-0-0 10-8-0 144-0 17-1-12 21-4-0 22-6-8 1-2-8 4-2-5 2-9-12 3-8-0 3-8-0 2-9-12 4-2-5 1 2-8 Scale = 1:39.8 I 5x5 = 2x3 ! i 5x5 = 4.00i12 D E F 1 2x3 2x3 ! � yj C G i 2 8 v5 1 \ / W B % /� H 04 4x8 = M L K J 4x8 = i3x4 = 3x10M1120H= 3x4 = 4x8 = i 1 _ 7-0-0 F 14-4-0 21-4-0 7-0-0 7.4-0 7-M 1 Plate Offsets (X,Y): [B:0-1-6,0-0-2] [H:0-1-6 0-0-21 i LOADING (psf) SPACING 2-0-0 j CSI DEFL in floc) I/deft Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.55 Vert(LL) 0.19 K >999 240 MT20 244/190 TCDL 10.0 Lumber Increase 1.25 BC 0.91 Vert(TQ -0.39 K >635 180 M1120H 187/143 BCLL 0.0 Rep Stress Incr NO WB 0.23 Horz(TL) 0.12 H n/a n/a BCDL 10.0 Code FBC2001/ANS195 (Matrix) Weight: 99 lb LUMBER 2) Wind: ASCE 7-98; 120mph (3-second gust); TOP CHORD 2 X 4 SYP No.2 h=15ft; TCDL=S.Opsf; BCDL=S.Opsf; Category 11; Exp Standard BOT CHORD 2 X 4 SYP No.2 B; enclosed; MWFRS interior zone; cantilever left and Uniform Loads (pit) WEBS 2 X 4 SYP No.3 right exposed ; Lumber DOL=1.33 plate grip Vert: A-D=-60, D-F=-125(F=-65), F-1=-60, B-M=-20, i DOL=1.33. J-M=-42(F=-22), H-J=-20 BRACING 3) Provide adequate drainage to prevent water Concentrated Loads (lb) TOP CHORD ponding. Vert: M=-513(F) J=-513(F) Sheathed or 2-7-5 oc purlins. 4) This truss has been designed for a 10.0 psf bottom j BOT CHORD chord live load nonconcurrent with any other live Rigid ceiling directly applied or 6-4-11 oc bracing. loads. 5) All plates are MT20 plates unless otherwise REACTIONS (lb/size) indicated. B = 1753/0-8-0 6) Provide mechanical connection (by others) of truss H = 1753/0-8-0 to bearing plate capable of withstanding 488 lb uplift Max Horz at joint B and 488 lb uplift at joint H. j B =-50(load case 6) 7) Girder carries hip end with 7-0-0 end setback. Max Uplift 8) "Fix heels only" Member end fixity model was used B =-488(load case 3) in the analysis and design of this truss. H =-488(load case 4) 9) Special hanger(s) or other connection device(s) shall be provided sufficient to support concentrated FORCES (lb) load(s) 5131b down and 1441b up at 14-4-0, and 5131b Maximum Compression/Maximum Tension down and 1441b up at 7-0-0 on bottom chord. The TOP CHORD design/selection of such special connection device(s) A-B = 0122 B-C =-4253/1057 is the responsibility of others. C-D =-4149/1019 D-E _-4408/1127 10) In the LOAD CASE(S) section, loads applied to j E-F = 4408/1127 F-G = 4149/1019 the face of the truss are noted as front (F) or back (B). I G-H =-4253/1057 H-1 = 0/22 11) NOTE: Refer to yellow bracing and/or T-1 sheet ' BOT CHORD for more information, B-M =-968/3944 L-M =-901/3874 12) NOTE: The seal on this drawing indicates K-L =-901/3874 J-K =-874/3874 acceptance of professional engineering H-J =-930/3944 responsibility solely for the truss component WEBS design shown. i C-M =-40/139 D-M =-95/681 13) NOTE: Trusses are designed for an Enclosed ! F-J =-95/681 G-J =-40/139 building condition as per building designer, E-K =-537/280 D-K =-211/710 assuming doors and windows are protected from F-K =-211/710 windbome debris impact as per Fla. Bldg. Code 1606.1.4 1 NOTES f 1) Unbalanceded roof live loads have been considered for LOAD CASE(S) this design. Standard IQLSAL H.A. G;^_,Cn 9, P.E. �} 25389 1) Regular: Lumber Increase=1.25, Plate 8850 I r t1^3 +/ t oulevard t— --- ----- Increase=1 25—-----„- — Orlando. FI_. 32824 Vey Job 'Truss Truss Type Qty—'!Ply 53107 / METRO DEV/ Sanford Housing / Bc 53107 ' R21 j ROOF TRUSS 1 1 Job Reference (optional) Trussway, Orlando, FI 6.100 a Sep 17 2004 MiTek Industries, Inc. Wed Oct 26 17:00:42 2005 Page 1 t i 7-4-9 9 0-0 12-4-0 13-11 8 21 -0 22-" 1-2-8 7-4-9 1-7-8 3-4-0 1-7-8 7-4-9 1-2-8 Scale = 1.39.81 i 5x5 = 5x5 = 4.00112 2x3 D T2 E 2x3 l .W6CA u� H 82 MiA 45 = J 1 45 = 46 = 5x 10 = 9-0-0 __-- — -- -- -- 12-4-0 21-4-0 r 9-0-0 3-4-0 9-0-0 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) Vdefl Ud PLATES GRIP TCLL 20.0 Plates Increase 1,25 TC 0.50 Vert(LL) -0.20 B-J >999 240 MT20 244/190 TCDL 10.0 Lumber Increase 1.25 BC 1.00 Vert(TL) -0.44 B-J >564 180 BCLL 0.0 Rep Stress Incr YES WB 0.15 Horz(TL) 0.05 G n/a n/a BCDL 10.0 Code FBC2001/ANSI95 (Matrix) Weight: 90lb LUMBER 2) Wind: ASCE 7-98; 110mph (3-second gust); TOP CHORD 2 X 4 SYP No.2 h=33ft; TCDL=S.Opsf; BCDL=S.Opsf; Category 11; Exp BOT CHORD 2 X 4 SYP No.2 B; enclosed; MWFRS interior zone and C-C Interior(1) WEBS 2 X 4 SYP No.3 zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33. This truss is BRACING designed for C-C for members and forces, and for TOP CHORD MWFRS for reactions specified. Sheathed or 4-1-0 oc purlins. 3) Provide adequate drainage to prevent water BOT CHORD ponding. Rigid ceiling directly applied or 10-0-0 oc bracing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live REACTIONS (lb/size) loads. B = 919/0-8-0 5) Provide mechanical connection (by others) of truss G = 919/0-8-0 to bearing plate capable of withstanding 184 lb uplift Max Horz at joint B and 184 lb uplift at joint G. B =-51(load case 7) 6) "Fix heels only" Member end fixity model was used Max Uplift in the analysis and design of this truss. B =-184(load case 4) 7) NOTE: Refer to yellow bracing and/or T-1 sheet for G =-184(load case 5) more information. i 8) NOTE: The seal on this drawing indicates FORCES (lb) acceptance of professional engineering Maximum Compression/Maximum Tension responsibility solely for the truss component design TOP CHORD shown. A-B = 0/22 B-C =-1752/395 9) NOTE: Trusses are designed for an Enclosed C-D =-1349/289 D-E _-1437/300 bilding condition as per building designer, E-F =-1349/289 F-G =-1752/395 assuming doors and windows are protected from G-H = 0/22 windborne debris impact as per Fla. Bldg. Code BOT CHORD 1606.1.4 B-J =-281/1594 1-1 =-281/1594 10) NOTE: Trusses are designed for an Enclosed G-1 =-281/1594 building condition as per building designer, WEBS assuming doors and windows are protected from C-J =-464/191 F-J =-464/191 windborne debris impact as per Fla. Bldg. Code D-J =-64/443 E-J =-64/443 1606.1.4 NOTES (7-10) LOAD CASE(S) I, 1) Unbalanced roof live loads have been considered for Standard this design. I ZIAL H !1 CAGr,lt P.E. # 25389 Il_.. f1'i'»0 i i i5 'e'd 'i 32Vc']Pt'f Oriao, .----------- sic82 r�. 282d ---'---------------- -- -- Job !Truss Truss Type iQty 1Ply 153107 / METRO DEV/ Sanford Housing / Bc 53107 ! R22 ROOF TRUSS I 1 1 Job Reference (optional) Trussway, Orlando, FI 6.100 a Sep 17 2004 MiTek Industries, Inc. Wed Oct 26 17:00:43 2005 Page 1 , `r-1-2-8 7-4-14 F 10-8-0 , 13-11-2 � 21-4-0 22-6-8 1-2-8 7-4-14 3-3-2 3-3-2 7-4-14 1-2-8 Scale = 1:39.0 5x5 = D ( 4.00 F12 2x3 Zx3 i C E G 4x5 = I H 4x5 = 4x8 = 3x6 = 10-8-0 21-4-0 + 10-8-0 10-8-0 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) Vdefl Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.51 Vert(LL) -0.20 F-I >999 240 MT20 244/190 TCDL 10.0 Lumber Increase 1.25 BC 0.82 Vert(TL) -0.44 F-1 >567 180 BCLL 0.0 Rep Stress Incr YES WB 0.24 Horz(TL) 0.05 F n/a n/a BCDL 10.0 Code FBC2001/ANSI95 (Matrix) Weight: 86lb LUMBER 2) Wind: ASCE 7-98; 120mph (3-second gust); TOP CHORD 2 X 4 SYP No.2 h=15ft; TCDL=5.Opsf; BCDL=5.Opsf; Category 11; Exp BOT CHORD 2 X 4 SYP No.2 'Except' B; enclosed; MWFRS interior zone and C-C Interior(1) B 1 2 X 4 SYP No.1 zone; cantilever left and right exposed ; Lumber WEBS 2 X 4 SYP No.3 DOL=1.33 plate grip DOL=1.33. This truss is designed for C-C for members and forces, and for BRACING MWFRS for reactions specified. TOP CHORD 3) This truss has been designed for a 10.0 psf bottom Sheathed or 4-0-12 oc purlins. chord live load nonconcurrent with any other live BOT CHORD loads. Rigid ceiling directly applied or 10-0-0 oc bracing. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 240 lb uplift REACTIONS (lb/size) at joint B and 240 lb uplift at joint F. i B = 919/0-8-0 5) "Fix heels only" Member end fixity model was used F = 919/0-8-0 in the analysis and design of this truss. Max Horz 6) NOTE: Refer to yellow bracing and/or T-1 sheet for B =-67(load case 7) more information. Max Uplift 7) NOTE: The seal on this drawing indicates B =-240(load case 4) acceptance of professional engineering F =-240(load case 5) responsibility solely for the truss component design shown. FORCES (lb) 8) NOTE: Trusses are designed for an Enclosed Maximum Compression/Maximum Tension building condition as per building designer, TOP CHORD assuming doors and windows are protected from A-B = 0/22 B-C =-1745/498 windborne debris impact as per Fla. Bldg. Code C-D =-1361/369 D-E =-1361/369 1606.1.4 E-F =-1746/498 F-G = 0/22 BOT CHORD LOAD CASE(S) B-1 =-366/1587 H-1 =-366/1588 Standard F-H =-366/1588 WEBS C-1 =-437/240 E-1 =-439/239 D-1 =-1721752 NOTES (6-8) 1) Unbalanced roof live loads have been considered for this design. n _ IQS i_ I" -- — - 6ti50 Truz n^l, vyaid Job Truss Truss Type oty Ply 53107 / METRO DEV/ Sanford Housing / Bc 53107 R23 !ROOF TRUSS 1 1 Job Reference (optional) Trussway, Orlando, FI 6.100 s Sep 17 2004 MiTek Industries, Inc. Wed Oct 26 17:00:43 2005 Page 1 I 1-2 8 7-4-14 10-8-0 , 13-11-2 21-4-0 1-2-8 7-4-14 3-3-2 3-3-2 7-4-14 Scale = 1:38.0I 5x5 = D 4.00112 2x3 2x3 � E C i B F /j . 45 = H G 45 = 48 = 3x6 = 10-8-0 21-4-0 10-8-0 10-8-0 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) Vdefl Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.55 Vert(LL) -0.20 F-H >999 240 MT20 244/190 TCDL 10.0 Lumber Increase 1.25 BC 0.82 Vert(TL) -0.45 F-H >554 180 BCLL 0.0 Rep Stress Incr YES WB 0.25 Horz(TL) 0.05 F n/a n/a BCDL 10.0 Code FBC2001/ANS195 (Matrix) Weight: 84lb LUMBER 2) Wind: ASCE 7-98; 120mph (3-second gust); TOP CHORD 2 X 4 SYP No.2 h=15ft; TCDL=S.Opsf; BCDL=S.Opsf; Category 11; Exp BOT CHORD 2 X 4 SYP No.2 'Except* B; enclosed; MWFRS interior zone and C-C Interior(1) B1 2 X 4 SYP No.1 zone; cantilever left and right exposed ; Lumber WEBS 2 X 4 SYP No.3 DOL=1.33 plate grip DOL=1.33. This truss is designed for C-C for members and forces, and for BRACING MWFRS for reactions specified. TOP CHORD 3) This truss has been designed for a 10.0 psf bottom Sheathed or 3-11-11 oc pudins. chord live load nonconcurrent with any other live BOT CHORD loads. Rigid ceiling directly applied or 9-2-7 oc bracing. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 159 lb uplift REACTIONS (lb/size) at joint F and 240 lb uplift at joint B. F = 823/0-8-0 5) "Fix heels only" Member end fixity model was used B = 923/0-8-0 in the analysis and design of this truss. Max Horz 6) NOTE: Refer to yellow bracing and/or T-1 sheet for B = 73(load case 6) more information. Max Uplift 7) NOTE: The seal on this drawing indicates F =-159(load case 5) acceptance of professional engineering B =-240(load case 4) responsibility solely for the truss component design shown. FORCES (lb) 8) NOTE: Trusses are designed for an Enclosed Maximum Compression/Maximum Tension building condition as per building designer, TOP CHORD assuming doors and windows are protected from A-B = 0/22 B-C =-1757/516 windborne debris impact as per Fla. Bldg. Code C-D =-13731389 D-E _-1375/391 1606.1.4 E-F =-1754/531 BOT CHORD LOAD CASE(S) B-H =-419/1598 G-H =-437/1611 Standard F-G =-437/1611 WEBS C-H =-437/238 E-H =-452/260 D-H =-1901764 NOTES (6-8) 1) Unbalanced roof live loads have been considered for this design. A. c:. ,GA , . . P. 253 3 3 FL. 32024 Mai 1 cuuv 53107 R30 ROOF TRUSS 11 1 107 / METRO DEV/ Sanford Housing / Bc 1-2-8 , 4-6-5 10-8-0 15-0-0 1-2-8 4-6-5 6-1-11 4-4-0 LOADING (psf) TCLL 20.0 TCDL 10.0 BCLL 0.0 BCDL 10.0 LUMBER TOP CHORD 2 X 4 SYP No.2 BOT CHORD 2 X 4 SYP No.2 WEBS 2 X 4 SYP No.3 BRACING TOP CHORD Sheathed or 3-4-6 oc purlins. BOT CHORD Rigid ceiling directly applied or 7-10-7 oc bracing. REACTIONS (lb/size) G = 951/Mechanical B = 1050/0-8-0 Max Horz B = 73(load rase 6) Max Uplift G =-192(load case 5) B =-253(load case 4) FORCES (Ib) Maximum Compression/Maximum Tension TOP CHORD A-B = 0/22 B-C =-2380/711 C-D =-2036/559 D-E _-2800/853 E-F =-2552/746 F-G =-2157/655 BOT CHORD B-J =-63112208 1-1 =-372/1531 H-1 =-372/1531 G-H =-559/1990 WEBS C-J =-414/254 D-J =-501500 D-H =-395/1402 E-H =-1095/396 F-H =-118/703 NOTES (8-10) 1) Unbalanced roof live loads have been considered for this design. 4.00 12 5x5 = D e 18-0-0 24-4-0 3-M 6-4-0 Scale = 1:44,9 3x6 = J I H 3x6 = 3x4 = 3x5 = 48 = F 7-0-1 15-0-0 18-0-0 21-4-12 24-4-0 7-0-1 7-11-15 3-M 3-4-12 2-11-4 SPACING 2-0-0 CSI I DEFL in (loc) I/defl Ud r— PLATES GRIP Plates Increase 1.25 TC 0.66 Vert(LL) -0.17 G-H >999 240 MT20 244/190 Lumber Increase 1.25 BC 0.77 Vert(TL) -0.41 G-H >705 180 Rep Stress Incr YES WB 0.45 Horz(TL) 0.06 G n/a n/a Code FBC2001/ANSI95 I (Matrix) Weight: 104lb 2) Wind: ASCE 7-98; 120mph (3-second gust); h=15ft; TCDL=5.Opsf; BCDL=5.Opsf; Category II; Exp B; enclosed; MWFRS interior zone and C-C Interior(1) zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33. This truss is designed for C-C for members and forces, and for MWFRS for reactions specified. 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 192 lb uplift at joint G and 253 lb uplift at joint B. 7) "Fix heels only" Member end fixity model was used in the analysis and design of this truss. 8) NOTE: Refer to yellow bracing and/or T-1 sheet for more information. 9) NOTE: The seal on this drawing indicates acceptance of professional engineering responsibility solely for the truss component design shown. 10) NOTE: Trusses are designed for an Enclosed building condition as per building designer, assuming doors and windows are protected from windborne debris impact as per Fla. Bldg. Code 1606.1.4 LOAD CASE(S) Standard LO IM 0 Orlando,�.824ard f+ 32 Job (Truss Truss Type my IPly 53107 / METRO DEV/ Sanford Housing / Bc 53107 R31 ROOF i TRUSS 1 1 Job Reference o tional Trussway, Orlando, FI 6.100 a Sep 17 2004 MiTek Industries, Inc. Wed Oct 26 17:00:44 2005 Page 1 1-2-8 5-11-0 10-8-0 13-0-0 16-0-0 18-6-13 , j 24-4-0 1-2-8 5-11-0 4-9-0 2-4-0 3-0-0 2-0-13 5-9-4 Scale = 1:44.9! i 5x5 = I 4.00j12 D 5x5 = 5x5 = 2x3 E F 3 2x3 ,..,...,\\�3 C �, j / G j 17 �j ,� W11 / u,A j ! j N n C ,J a 3x6 L K J I 3x6 3x4 = 3x5 = 48 = 3x4 = i— 5-10-12 13-0-0 _+ 16-0-0 24-4-0 6-10-12 6-1-4 3-" 8-4-0 LOADING (psf) SPACING 2-0-0 CSI j DEFL in (loc) Vdefl Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.39 Vert(LL) 0.13 J-L >999 240 MT20 244/190 TCDL 10.0 Lumber Increase 1.25 BC 0.62 Vert(TL) -0.29 H-1 >998 180 BCLL 0.0 Rep Stress Incr YES WB 0.29 Horz(TL) 0.07 H n/a n/a BCDL 10.0 Code FBC2001/ANSI95 (Matrix) Weight: 110lb LUMBER 2) Wind: ASCE 7-98; 120mph (3-second gust); TOP CHORD 2 X 4 SYP No.2 h=15ft; TCDL=5.Opsf; BCDL=5.Opsf; Category 11; Exp BOT CHORD 2 X 4 SYP No.2 B; enclosed; MWFRS interior zone and C-C Interior(1) WEBS 2 X 4 SYP No.3 zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33. This truss is BRACING designed for C-C for members and forces, and for TOP CHORD MWFRS for reactions specified. Sheathed or 3-9-5 oc purlins. 3) Provide adequate drainage to prevent water BOT CHORD ponding. Rigid ceiling directly applied or 7-10-7 oc bracing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live REACTIONS (lb/size) loads. H = 951/Mechanical 5) Refer to girder(s) for truss to truss connections. B = 1050/0-8-0 6) Provide mechanical connection (by others) of truss Max Horz to bearing plate capable of withstanding 192 lb uplift B = 73(load case 6) at joint H and 252 lb uplift at joint B. Max Uplift 7) "Fix heels only" Member end fixity model was used H =-192(load case 5) in the analysis and design of this truss. B =-252(load case 4) 8) NOTE: Refer to yellow bracing and/or T-1 sheet for more information. FORCES (lb) 9) NOTE: The seal on this drawing indicates Maximum Compression/Maximum Tension acceptance of professional engineering TOP CHORD responsibility solely for the truss component design A-B = 0/22 B-C =-2273/645 shown. C-D =-2116/630 D-E =-2175/709 10) NOTE: Trusses are designed for an Enclosed i E-F =-2004/637 F-G =-2008/609 building condition as per building designer, G-H =-2292/711 assuming doors and windows are protected from BOT CHORD windborne debris impact as per Fla. Bldg. Code B-L =-554/2091 K-L =-374/1533 1606.1.4 J-K =-374/1533 1-1 =-462/1848 H-1 =-621/2131 LOAD CASE(S) WEBS Standard C-L =-302/185 D-L =-128/600 D-J =-279/905 E-J =-840/317 F-I =-60/352 G-1 =-336/194 F-J =-76/225 NOTES (8-10) i 1) Unbalanced roof live loads have been considered for this design.25389 / LZ avard C 3izn O, FL. 32624 — __- goo truss truss type I utv 1 riv 153107 / METRO DEV/ Sanford Housing / Bc 53107 R32 ROOF TRUSS 1 1 1 ; Job Reference (optional) Trussway, Orlando, FI 6.100 a Sep 17 2004 MiTek Industries, Inc. Wed Oct 26 17:00:45 2605 Page 1 j 1-2 8 i 6-9-3 10-8-0 11-Q-0 14-0-0 18-0-9 19-2-0j 24-4-0 1-2-8 6-9-3 3-10-13 0-4-0 3-0-0 4-0-9 1-1-7 5-2-0 j Scale = 1:44.9 I 5x8 = 10-8-0 5x5 = 4.00 j 12 E 2x3 / 2x3 \\ C_�F `\W13 W� / NVj1 I I tar ram) \` 12 i / \., I WI \\ �� G B ^� \ -A ��i 62 1 ( - ____vi lLn o d 46 = J 1 H 4x5 = i 3x4 = 3x5 = 48 = 10-0-0 111-0-q 14-8-13 18-0-9 19-2-0+ 24-4-0 10-0-0 1-M 3.8-13 r 3-3-12 1-1-7 5-2-0 Plate Offsets X Y : E:0-2-8 0-2-11 G:0-2-14 0-0-2 LOADING (psf) SPACING 2-0-0 I i CSI DEFL in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 I TC 0.47 Vert(LL) -0.22 B-J >999 240 MT20 244/190 TCDL 10.0 I Lumber Increase 1.25 BC 0.73 j Vert(TL) -0.49 B-J >584 180 BCLL 0.0 1 Rep Stress Incr YES I WB 0.15 I Horz(TL) 0.07 G n/a n/a BCDL 10.0 Code FBC2001/ANS195 (Matrix) i Weight: 105lb J LUMBER TOP CHORD 2 X 4 SYP No.2 BOT CHORD 2 X 4 SYP No.2 WEBS 2 X 4 SYP No.3 BRACING TOP CHORD Sheathed or 3-8-4 oc purlins. BOT CHORD Rigid ceiling directly applied or 7-9-15 oc bracing. REACTIONS (lb/size) G = 951/Mechanical B = 1050/0-8-0 Max Horz B = 73(load case 6) Max Uplift G = 191(load case 5) B = -253(load case 4) FORCES (lb) Maximum Compression/Maximum Tension TOP CHORD A-B = 0/22 B-C =-2151/662 C-D =-1809/537 D-E =-1634/538 E-F =-18331553 F-G =-22401713 BOT CHORD B-J =-560/1988 1-1 =-365/1580 H-1 =-365/1580 G-H =-619/2083 WEBS F-H =-462/260 D-J =-47/385 E-H =-48/350 C-J =-396/219 D-H =-86/192 NOTES (8-10) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-98; 120mph (3-second gust); h=15ft; TCDL=5.Opsf; BCDL=5.Opsf; Category II; Exp B; enclosed; MWFRS interior zone and C-C Interior(1) zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33. This truss is designed for C-C for members and forces, and for MWFRS for reactions specified. 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 191 lb uplift at joint G and 253 lb uplift at joint B. 7) "Fix heels only" Member end fixity model was used in the analysis and design of this truss. 8) NOTE: Refer to yellow bracing and/or T-1 sheet for more information. 9) NOTE: The seal on this drawing indicates acceptance of professional engineering responsibility solely for the truss component design shown. 10) NOTE: Trusses are designed for an Enclosed building condition as per building designer, assuming doors and windows are protected from windborne debris impact as per Fla. Bldg. Code 1606.1.4 LOAD CASE(S) Standard Odando, FL. 32824 Housing 153107 j R33 !ROOF TRUSS e Sep 17 2004 MiTek Industries, Inc. Wed Oct 26 17:00:45 2005 1-2 8 6-9-0 1 12-2-0 �_ 17 8-0 24-4-0 1-2-8 6-9-0 5-5-0 5-6-0 6-8-0 A nnli7 5x5 = C• Scale = 1:45.411 3x6 = J I H G 3x4 = 3x5 = 4x9 = 2x4 II LOADING (psf) I SPACING 2-0-0 TCLL 20.0 Plates Increase 1.25 TCDL 10.0 Lumber Increase 1.25 BCLL 0.0 Rep Stress Incr YES BCDL 10.0 Code FBC2001/ANS195 LUMBER TOP CHORD 2 X 4 SYP No.2 'Except' T3 2 X 4 SYP No.1 BOT CHORD 2 X 4 SYP No.2 WEBS 2 X 4 SYP No.3 BRACING TOP CHORD Sheathed or 3-1.15 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 7-11-0 oc bracing. REACTIONS (lb/size) G = 951/Mechanical B = 1050/0-8-0 Max Horz B = 134(load case 6) Max Uplift G = -189(load case 5) B = -257(load case 4) FORCES (lb) Maximum Compression/Maximum Tension TOP CHORD A-B = 0/22 B-C =-2254/611 C-D =-2107/613 D-E =-2231/661 E-F =-2010/555 F-G =-9061318 BOT CHORD B-J =-613/2069 1-1 =-406/1356 H-1 =-40611356 G-H = 0/0 WEBS C-J =-353/222 D-J =-165/794 D-H =-217/901 E-H =-1055/421 F-H =-588/2132 NOTES (8-10) 1) Unbalanced roof live loads have been considered for this design. 17-8-0 0-0-10 CSI I DEFL in floc) Vdefl TC 0.83 ( Vert(LL) -0.24 H-J >999 BC 0.85 Vert(TL) -0.53 H-J >539 WB 0.68 Horz(TL) 0.04 G n/a (Matrix) 2) Wind: ASCE 7-98; 120mph (3-second gust); h=15ft; TCDL=5.Opsf; BCDL=5.Opsf; Category II; Exp B; enclosed; MWFRS interior zone and C-C Interior(1) zone; cantilever left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33. This truss is designed for C-C for members and forces, and for MWFRS for reactions specified. 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 189 lb uplift at joint G and 257 lb uplift at joint B. 7) "Fix heels only" Member end fixity model was used in the analysis and design of this truss. 8) NOTE: Refer to yellow bracing and/or T-1 sheet for more information. 9) NOTE: The seal on this drawing indicates acceptance of professional engineering responsibility solely for the truss component design shown. 10) NOTE: Trusses are designed for an Enclosed building condition as per building designer, assuming doors and windows are protected from windborne debris impact as per Fla. Bldg. Code 1606.1.4 LOAD CASE(S) Standard Ud ( PLATES GRIP 240 MT20 244/190 180 n/a Weight: 113 lb H.A. GnC,,-) P.E. ..._ !. 7'1 53107 1R40 Trussway, Orlando, FI I 1-2-8 4.00 1 12 u� ROOFTRUSS 3-0-0 3-0-0 Qty Ply 53107 / METRO DEV/ 1 1 Job Reference (optional) 6.100 a Sep 17 2004 MiTek Industries, Inc. 4-0-0 7-M 1-M 3-0-0 3x3 = 3x3 C D ng 2005 Page 1-2-8 i Scale = 1:15.8 jt2 JA 16 4x4 = 4x4 = 3-M LOADING (psf) SPACING 2-0-0 TCLL 20.0 Plates Increase 1.25 TCDL 10.0 Lumber Increase 1.25 BCLL 0.0 Rep Stress Incr NO BCDL 10.0 Code FBC2001/ANSI95 LUMBER TOP CHORD 2 X 4 SYP No.2 BOT CHORD 2 X 4 SYP No.2 BRACING TOP CHORD Sheathed or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) B = 409/0-8-0 E = 409/0-8-0 Max Horz B =-31(load case 6) Max Uplift B =-154(load case 3) E _-154(load case 4) FORCES (lb) Maximum Compression/Maximum Tension TOP CHORD A-B = 0122 B-C =-425/96 C-D =-387/98 D-E =-425/96 E-F = 0/22 BOT CHORD B-G =-601387 G-H =-60/387 E-H =-60/387 NOTES (10-12) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-98; 120mph (3-second gust); h=15ft; TCDL=5.Opsf; BCDL=5.Opsf; Category 11; Exp B; enclosed; MWFRS interior zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33. 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 154 lb uplift at joint B and 154 lb uplift at joint E. 4-0-0 1-0-0 CSI DEFL in (loc) I/defl TC 0.25 Vert(LL) -0.03 B-E >999 BC 0.35 Vert(TL) -0.09 B-E >867 WB 0.00 Horz(TL) 0.00 E n/a (Matrix) 6) Girder carries hip end with 3-0-0 end setback. 7) "Fix heels only" Member end fixity model was used in the analysis and design of this truss. 8) Special hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 601b down and 171b up at 4-0-0, and 601b down and 171b up at 3-0-0 on bottom chord. The design/selection of such special connection device(s) is the responsibility of others. 9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). 10) NOTE: Refer to yellow bracing and/or T-1 sheet for more information. 11) NOTE: The seal on this drawing indicates acceptance of professional engineering responsibility solely for the truss component design shown. 12) NOTE: Trusses are designed for an Enclosed building condition as per building designer, assuming doors and windows are protected from windborne debris impact as per Fla. Bldg. Code 1606.1.4 LOAD CASE(S) Standard 1) Regular: Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: A-C=-60, C-D=-65(F=-5), D-F=-60, B-G=-20, G-H=-22(F=-2), E-H=-20 Concentrated Loads (lb) Vert: G=-60(F) H=-60(F) 3-M Ud PLATES GRIP 240 MT20 244/190 180 n/a Weight: 25 lb H.A,. C:�CgiJ p� 8,20 Tres; E• 25389 OrtardoU� �ffltltevard . 32824 'Job 'Truss Truss Type - 'Oty Ply 153107 / METRO DEV/ Sanford Housing / Bc 53107 R41 I ROOF TRUSS 1 1 Job Reference (optional) Trussway, Orlando, FI 6.100 a Sep 17 2004 MiTek Industries, Inc. Wed Oct 26 17:00:46 2005 Paget j -1-2-8 3-6-0 7-" 8-2-8 l 1-2-8 3-6-0 3-6-0 1-2-8 i Scale = 1:15.51 3x3 C 4.00 12 YJ's T2 D E I, 3x3 = 3x3 = I 3-6-0 7-0-0 3-6-0 3-" Plate Offsets X Y : C:0-1-8 Edge] PLATES GRIP LOADING (psf) SPACING 2-M CSI DEFL in floc) I/deft Ud TCLL 20.0 Plates Increase 1.25 TC 0.20 Vert(LL) -0.08 B-D >900 240 MT20 244/190 TCDL 10.0 Lumber Increase 1.25 BC 0.38 Vert(TL) -0.17 B-D >450 180 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(TL) 0.00 D n/a n/a BCDL 10.0 Code FBC2001/ANSI95 (Matrix) Weight: 25 lb LUMBER 5) "Fix heels only" Member end fixity model was used TOP CHORD 2 X 4 SYP No.2 in the analysis and design of this truss. BOT CHORD 2 X 4 SYP No.2 6) NOTE: Refer to yellow bracing and/or T-1 sheet for more information. BRACING 7) NOTE: The seal on this drawing indicates TOP CHORD acceptance of professional engineering j Sheathed or 6-0-0 oc purlins. responsibility solely for the truss component design BOT CHORD shown. Rigid ceiling directly applied or 10-0-0 oc bracing. 8) NOTE: Trusses are designed for an Enclosed building condition as per building designer, ; REACTIONS (lb/size) assuming doors and windows are protected from B = 346/0-8-0 windbome debris impact as per Fla. Bldg. Code D = 346/0-8-0 1606.1.4 Max Horz B =-33(load case 7) LOAD CASE(S) Max Uplift Standard B = 134(load case 4) D = 134(load case 5) FORCES (lb) Maximum Compression/Maximum Tension TOP CHORD A-B = 0/22 B-C =-247/82 C-D =-247/82 D-E = 0/22 BOT CHORD B-D =-44/192 NOTES (6-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-98; 120mph (3-second gust); h=15ft; TCDL=5.Opsf; BCDL=5.Opsf; Category II; Exp B; enclosed; MWFRS interior zone and C-C Interior(1) zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33. This truss is designed for C-C for members and forces, and for MWFRS for reactions specified. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) Provide mechanical connection (by others) of truss to IC ".t I-I.A CAGAN P.E. # 25389 bearing plate capable of withstanding 134 lb uplift at L85J i ra t.'<:'/t3t3"ward joint B and 134 lb uplift at joint D. Gr'fando, FL. 32824 53107 RG1 ROOF TRUSS 1 1 Sanford Housing Project i Job Reference (optional) Trussway, Orlando, FI 6.100 s Sep 17 2004 MiTek Industries, Inc. Wed Oct 26 17:00:46 w a 3-6-0 7-0-0 3-6-0 3-6-0 2x3 II C 45 = 45 = Scale = 1:1 3-6-0 7-M 3-6-0 3-6-0 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/defl Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.22 Vert(LL) 0,03 D-E >999 240 MT20 244/190 TCDL 10.0 Lumber Increase 1.25 BC 0.80 Vert(TL) -0.07 D-E >999 180 BCLL 0.0 Rep Stress Incr NO WB 0.62 Horz(TL) 0.01 D n/a n/a BCDL 10.0 Code FBC2001/ANSI95 i (Matrix) Weight: 36 lb LUMBER TOP CHORD 2 X 4 SYP No.2 BOT CHORD 2 X 6 SYP No.2 WEBS 2 X 4 SYP No.3 BRACING TOP CHORD Sheathed or 3-9-12 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) A = 1503/0-8-0 D = 1503/Mechanical Max Horz A = 85(load case 3) Max Uplift A = -327(load case 3) D = -356(load case 3) FORCES (lb) Maximum Compression/Maximum Tension TOP CHORD A-B =-2536/535 B-C = -26/25 BOT CHORD A-E =-566/2369 D-E =-566/2369 WEBS C-D =-100/47 B-E =-270/1421 B-D =-2496/596 NOTES (8-10) 1) Wind: ASCE 7-98; 120mph (3-second gust); h=15ft; TCDL=5.Opsf; BCDL=5.Opsf; Category II; Exp B; enclosed; MWFRS interior zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33. 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Refer to girder(s) for truss to truss connections. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 327 lb uplift at joint A and 356 lb uplift at joint D. 5) Girder carries tie-in span(s): 21-4-0 from 0-0-0 to 7-0-0 6) "Fix heels only" Member end fixity model was used in the analysis and design of this truss. 7) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). 8) NOTE: Refer to yellow bracing and/or T-1 sheet for more information. 9) NOTE: The seal on this drawing indicates acceptance of professional engineering responsibility solely for the truss component design shown. 10) NOTE: Trusses are designed for an Enclosed building condition as per building designer, assuming doors and windows are protected from windbome debris impact as per Fla. Bldg. Code 1606.1.4 LOAD CASE(S) Standard 1) Regular: Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: A-C=-60, A-D=-401(F=-381) M1JYIuiiN�� FL 3 824 1153107 N r 'Truss Truss Type i oty Ply 53107 RG2 i ROOF TRUSS Job Refere Orlando, FI 6.100 a Sep 17 2004 MiT 2_10-8 6-4-0 2-10-8 35-8 5x5 = B 4.00 2 nford 261 Scale = 1:10.8 C 2x3 i I 45 = 45 = 2-10-8 LOADING (psf) SPACING 2-0-0 TCLL 20.0 Plates Increase 1.25 TCDL 10.0 Lumber Increase 1.25 BCLL 0.0 Rep Stress Incr NO BCDL 10.0 Code FBC2001/ANS195 LUMBER TOP CHORD 2 X 4 SYP No.2 BOT CHORD 2 X 6 SYP No.2 WEBS 2 X 4 SYP No.3 BRACING TOP CHORD Sheathed or 3-7-13 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) A = 1538/0-8-0 D = 1534/0-4-0 Max Horz A = 35(load case 5) Max Uplift A = -349(load case 3) D = -353(load case 3) FORCES (lb) Maximum Compression/Maximum Tension TOP CHORD A-B =-2850/621 B-C = 0/0 C-D =-105/49 BOT CHORD A-E =-599/2663 D-E =-555/2432 WEBS B-E =-286/1462 B-D =-2522/575 NOTES (10-12) 1) Wind: ASCE 7-98; 120mph (3-second gust); h=15ft; TCDL=5.Opsf; BCDL=5.Opsf; Category II; Exp B; enclosed; MWFRS interior zone; cantilever left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33. 2) Provide adequate drainage to prevent water ponding. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 349 lb uplift at joint A and 353 lb uplift at joint D. 5) Girder carries tie-in span(s): 24-4-0 from 0-0-0 to 3-5-8 CSI DEFL in (loc) Vdefl Ud TC 0.18 Vert(LL) 0.04 D-E >999 240 BC 0.97 Vert(TL) -0.08 D-E >906 180 WB 0.63 Horz(TL) 0.01 D n/a n/a (Matrix) 6) Girder carries hip end with 2-10-8 end setback. 7) "Fix heels only" Member end fixity model was used in the analysis and design of this truss. 8) Special hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 531b down and 151b up at 2-10-8 on bottom chord. The design/selection of such special connection device(s) is the responsibility of others. 9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). 10) NOTE: Refer to yellow bracing and/or T-1 sheet for more information. 11) NOTE: The seal on this drawing indicates acceptance of professional engineering responsibility solely for the truss component design shown. 12) NOTE: Trusses are designed for an Enclosed building condition as per building designer, assuming doors and windows are protected from windborne debris impact as per Fla. Bldg. Code 1606.1.4 LOAD CASE(S) Standard 1) Regular: Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: A-B=-60, B-C=-63(F=-3), A-E=-453(F=-433), D-E=-454(F=-434) Concentrated Loads (lb) Vert: E=-53(F) PLATES GRIP MT20 244/190 Weight: 31 lb i Job Truss i Truss Type oty Ply 53107 1 METRO DEV/ Sanford Housing Bc �53107 ivol i ROOF TRUSS i Job Reference (optional) Trussway, Orlando, FI 6.106 e Sep 17 2004 MiTek Industries, Inc. Wed Oct 26 17:00:4-72005—P­age 1 3x3 1-11-4 3-10-8 1-11-4 1-11-4 4.00,71-2 B Scale = 1:6.41 C A B1 Ic 3x3 3x3 z�- 3-10-8 3-10-8 Plate Offsets (X,Y): IB:0-1-8,Edgel LOADING (psf) SPACING 2-0-0 Csl j DEFL in (loc) Vdefl Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.03 Vert(LL) n/a n/a 999 MT20 244/190 TCDL 10.0 Lumber Increase 1.25 BC 0.04 Vert(TL) n/a n/a 999 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(TL) 0.00 C n/a n/a BCDL 10.0 Code FBC2001/ANSI95 (Matrix) Weight: 9 lb LUMBER TOP CHORD 2 X 4 SYP No.3 3) This truss has been designed for a 10.0 psf bottom live load live BOT CHORD 2 X 4 SYP No.3 chord nonconcurrent with any other loads. 4) Gable requires continuous bottom chord bearing. BRACING 5) Provide mechanical connection (by others) of truss TOP CHORD to bearing plate capable of withstanding 7 lb uplift at Sheathed or 4-0-0 oc purlins. joint A, 7 lb uplift at joint C, I lb uplift at joint E and 1 BOT CHORD lb uplift at joint D. Rigid ceiling directly applied or 10-0-0 oc bracing. 6) "Fix heels only" Member end fixity model was used in the analysis and design of this truss. REACTIONS (lb/size) 7) NOTE: Refer to yellow bracing and/or T- I sheet for A = 84/3-10-8 more information. C = 84/3-10-8 8) NOTE: The seal on this drawing indicates E -0/3-10-8 acceptance of professional engineering D =-0/3-10-8 responsibility solely for the truss component design Max Horz shown. E -5(load case 7) 9) NOTE: Trusses are designed for an Enclosed Max Uplift building condition as per building designer, A =-7(load case 4) assuming doors and windows are protected from C =-7(load case 5) windborne debris impact as per Fla. Bldg. Code E 1 (load case 2) 1606.1.4 D = 1 (load case 2) LOAD CASE(S) FORCES (lb) Standard Maximum Compression/Maximum Tension TOP CHORD A-B = -77/45 B-C = -77/45 BOT CHORD A-E = -5/5 A-C = -31/64 C-D = 010 NOTES (7-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-98; 120mph (3-second gust); h=15ft; TCDL=5.Opsf; BCDL=5.Opsf; Category 11; Exp B: enclosed; MWFRS interior zone and C-C Interior(l) zone; cantilever left and right exposed ; Lumber 1 DOL=1.33 plate grip DOL=1.33. This truss is designed C--, i for C-C for members and forces, and for MWFRS for reactions specified, 4,rd goo I i russ Truss Type oty Ply 53107 / METRO DEV/ Sanford Housing / Bc 153107 V02 ROOF TRUSS 1 1 1 ' Job Reference (optional) Trussway, Orlando, FI 6.100 a Sep 17 2004 MiTek Industries, Inc. Wed Oct 26 17:00:47 2005 Page 1 3 11-4 7-10-8 3-11.4 3-11-4 Scale = 1:12.9 3x3 = 4.00 ,72 B 1 VT C A y r/ B 1 O O 3x3 3x3 7-10-8 7-10-8 Plate Offsets X Y : B:0-1-8 Ed e LOADING (psf) SPACING 2-M CSI DEFL in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.11 Vert(LL) n/a - n/a 999 MT20 244/190 TCDL 10.0 Lumber Increase 1.25 BC 0.33 Vert(TL) n/a - n/a 999 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(TL) 0.00 C n/a n/a BCDL 10.0 Code FBC2001/ANSI95 (Matrix) I Weight: 21 lb LUMBER 2) Wind: ASCE 7-98; 120mph (3-second gust); TOP CHORD 2 X 4 SYP No.2 h=15ft; TCDL=S.Opsf; BCDL=S.Opsf; Category 11; Exp BOT CHORD 2 X 4 SYP No.3 B; enclosed; MWFRS interior zone and C-C Interior(1) zone; cantilever left and right exposed; Lumber BRACING DOL=1.33 plate grip DOL=1.33. This truss is TOP CHORD designed for C-C for members and forces, and for Sheathed or 6-0-0 oc purlins. MWFRS for reactions specified. BOT CHORD 3) This truss has been designed for a 10.0 psf bottom Rigid ceiling directly applied or 10-0-0 oc bracing. chord live load nonconcurrent with any other live loads. REACTIONS (Ib/size) 4) Gable requires continuous bottom chord bearing. A = 292/7-10-8 5) Provide mechanical connection (by others) of truss C = 292/7-10-8 to bearing plate capable of withstanding 8 lb uplift at E _-55/7-10-8 joint A, 8 lb uplift at joint C, 109 lb uplift at joint E and D =-5517-10-8 109 lb uplift at joint D. Max Horz 6) "Fix heels only" Member end fixity model was used E = 15(load case 6) in the analysis and design of this truss. Max Uplift 7) NOTE: Refer to yellow bracing and/or T-1 sheet for A =-8(load case 4) more information. C =-8(load case 5) 8) NOTE: The seal on this drawing indicates E _-109(load case 2) acceptance of professional engineering D =-109(load case 2) responsibility solely for the truss component design Max Grav shown. A = 306(load case 2) 9) NOTE: Trusses are designed for an Enclosed C = 306(load case 2) building condition as per building designer, assuming doors and windows are protected from FORCES (lb) windbome debris impact as per Fla. Bldg. Code Maximum Compression/Maximum Tension 1606.1.4 TOP CHORD A-B =-262/147 B-C =-262/147 LOAD CASE(S) BOT CHORD Standard A-E _ -15/15 A-C =-110/223 C-D = 0/0 NOTES (7-9) 1) Unbalanced roof live loads have been considered for this design. I i nl.Pr.i`2-,Z80 ! to t� Ugg ] E ,-.• °�vuad G I4t:... i 3 L JiV2W r;, . / ZuU6 53107 / METRO DEV/ 53107 IV2 Q 0 ROOFTRUSS �1 1 i 6.100 a Sep 3-11-4 3-11-4 B 2x3 I i 3x3 % 2x3 II LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) Well Ud TCLL 20.0 Plates Increase 1.25 TC 0.09 Vert(LL) n/a n/a 999 TCDL 10.0 Lumber Increase 1.25 BC 0.09 Vert(TL) n/a n/a 999 BCLL 0.0 Rep Stress Incr YES WB 0.02 Horz(TL) -0.00 A n/a n/a BCDL 10.0 Code FBC2001/ANS195 (Matrix) LUMBER TOP CHORD 2 X 4 SYP No.2 BOT CHORD 2 X 4 SYP No.3 WEBS 2 X 4 SYP No.3 BRACING TOP CHORD Sheathed or 8-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) A = 136/3-11-4 D = -10/3-11-4 C = 100/3-11-4 Max Horz D = 38(load case 4) Max Uplift A = -1(load case 4) D = -21(load case 2) C = -34(load case 4) Max Grav A = 140(load case 2) C = 100(load case 1) FORCES (lb) Maximum Compression/Maximum Tension TOP CHORD A-B = -29/22 BOT CHORD A-D = -47/0 A-C = 0/0 WEBS B-C = -79/58 NOTES (6-8) 1) Wind: ASCE 7-98; 120mph (3-second gust); h=15ft; TCDL=S.Opsf; BCDL=S.Opsf; Category II; Exp B; enclosed; MWFRS interior zone and C-C Interior(1) zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33. This truss is designed for C-C for members and forces, and for MWFRS for reactions specified. 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Gable requires continuous bottom chord bearing. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1 lb uplift at joint A, 21 lb uplift at joint D and 34 lb uplift at joint C. 5) "Fix heels only" Member end fixity model was used in the analysis and design of this truss. 6) NOTE: Refer to yellow bracing and/or T-1 sheet for more information. 7) NOTE: The seal on this drawing indicates acceptance of professional engineering responsibility solely for the truss component design shown. 8) NOTE: Trusses are designed for an Enclosed building condition as per building designer, assuming doors and windows are protected from windborne debris impact as per Fla. Bldg. Code 1606.1.4 LOAD CASE(S) Standard 7 PLATES GRIP MT20 244/190 Weight: 11 lb 2005 Page Scale = 1:9.0 .__ ...L. 25Z 14- Iru55 truss type duty 1Fly 53107 / METRO DEV/ Sanford Housing / Bc 153107 1V3 MONO TRUSS �1 1 Job Reference (optional) Trussway, Orlando, FI 6.100 s Sep 17 2004 MiTek Industries, Inc. Wed Oct 26 17:00:48 2005 Page 1 5-11-4 —i 5-11-4 2x3 II Scale: V=1' B v 0 0 3x3 % 2x3 II LOADING (psf) SPACING 2-0-0 TCLL 20.0 Plates Increase 1.25 TCDL 10.0 Lumber Increase 1.25 BCLL 0.0 Rep Stress Incr YES BCDL 10.0 Code FBC2001/ANS195 LUMBER TOP CHORD 2 X 4 SYP No.2 BOT CHORD 2 X 4 SYP No.3 WEBS 2 X 4 SYP No.3 BRACING TOP CHORD Sheathed or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) D =-40/5-11-4 C = 171/5-11-4 A = 248/5-11-4 Max Horz D = 63(load case 4) Max Uplift D =-81(load case 2) C =-57(load case 4) Max Grav C = 171(load case 1) A = 270(load case 2) FORCES (lb) Maximum Compression/Maximum Tension TOP CHORD A-B = -48/37 BOT CHORD A-D = -78/0 A-C = 0/0 WEBS B-C =-135/98 NOTES (6-8) 1) Wind: ASCE 7-98; 120mph (3-second gust); h=15ft; TCDL=5.Opsf; BCDL=5.Opsf; Category 11; Exp B; enclosed; MWFRS interior zone and C-C Interior(1) zone; cantilever left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33. This truss is designed for C-C for members and forces, and for MWFRS for reactions specified. 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5-11-4 CSI DEFL in (loc) I/defl TC 0.28 Vert(LL) n/a n/a BC 0.28 Vert(TL) n/a n/a WB 0.03 Horz(TL) -0.00 C n/a (Matrix) 3) Gable requires continuous bottom chord bearing. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 81 lb uplift at joint D and 57 lb uplift at joint C. 5) "Fix heels only" Member end fixity model was used in the analysis and design of this truss. 6) NOTE: Refer to yellow bracing and/or T-1 sheet for more information. 7) NOTE: The seal on this drawing indicates acceptance of professional engineering responsibility solely for the truss component design shown. 8) NOTE: Trusses are designed for an Enclosed building condition as per building designer, assuming doors and windows are protected from windborne debris impact as per Fla. Bldg. Code 1606.1.4 LOAD CASE(S) Standard Ud PLATES GRIP 999 MT20 244/190 999 n/a Weight: 18 lb 53107 iV4 MONO TRUSS 1 1 1 Housing / Bc c a 0 2-9-12 2-9-12 4.00112 6.100 s Sep 17 Scale = 1:6.E 3x3 % 2x3 11 3-11-4 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft Ud TCLL 20.0 Plates Increase 1.25 TC 0.09 Vert(LL) n/a n/a 999 TCDL 10.0 Lumber Increase 1.25 BC 0.10 I Vert(TL) n/a n/a 999 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(TL) 0.00 D n/a n/a BCDL 10.0 Code FBC2001/ANS195 (Matrix) LUMBER TOP CHORD 2 X 4 SYP No.3 BOT CHORD 2 X 4 SYP No.3 WEBS 2 X 4 SYP No.3 BRACING TOP CHORD Sheathed or 4-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) E _ -42/3-11-4 D = 99/3-11-4 A = 176/3-11-4 Max Horz E = 25(load case 4) Max Uplift E _ -42(load case 1) D = -26(load case 4) A = -33(load case 4) Max Grav E = 14(load case 4) D = 99(load case 1) A = 176(load case 1) FORCES (lb) Maximum Compression/Maximum Tension TOP CHORD A-B = -97/27 C-D = -67/50 B-C = -67/32 BOT CHORD A-E _ -32/0 A-D = -32/67 NOTES (8-10) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-98; 120mph (3-second gust); h=15ft; TCDL=S.Opsf; BCDL=S.Opsf; Category II; Exp B; enclosed; MWFRS interior zone and C-C Interior(1) zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33. This truss is designed for C-C for members and forces, and for MWFRS for reactions specified. 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Gable requires continuous bottom chord bearing. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 42 lb uplift at joint E, 26 lb uplift at joint D and 33 lb uplift at joint A. 7) "Fix heels only" Member end fixity model was used in the analysis and design of this truss. 8) NOTE: Refer to yellow bracing and/or T-1 sheet for more information. 9) NOTE: The seal on this drawing indicates acceptance of professional engineering responsibility solely for the truss component design shown. 10) NOTE: Trusses are designed for an Enclosed building condition as per building designer, assuming doors and windows are protected from windborne debris impact as per Fla. Bldg. Code 1606.1.4 LOAD CASE(S) Standard PLATES GRIP MT20 244/190 Weight: 11 lb i 2:7S^3 0 Agchb ROOF LOADING TCLL TCLL 20 24" O.C. 10 1.25% OF TCLL 0 TRUSSWAY. LM. TCLL 10 ru =dr. �Mifrl PSF 40# (407) 857-2777 PH (407) MI-7809 PAX WIND ASCE.7-98 0 120 MPH iwrmaw I www. blmwav cmn ROOF HANGER SCHEDULE MARK DESCRIPTION SIMPSON USP I RH.3 HUS26 THD26 I' Y P C'A lL 1-11, P !'�UAILIN'-1 ROOF TRUSS PLACEMENT cr w REFER TO SHT."T-I"&(nN FOR IMPORTANT 00 INFORMATION! 0 DATE : 10-27-5 DRAWN BY: 8c co CHECK BY: JOB NO. 53I07 SCALE NTS 3: 5310zdwg SHEET ALL BEAMS ARE DE9GNE0 BY OTHERS RE: S7RUCAIRA PLANS FOR BEAM -92rS DBBo=DRop BEAM BY OTHERS T Fb?80=FlU5H BEAU BY OTHERS �C, STA RD RoOP ILS R 1.0 - JUNE 2003 STRUCTURAL COORDINATION REFER TO ARCHITECTURAL/ENGINEERING PLANS FOR STRUCTRAL ENTITIES (BEAMS, HEADERS, SEISMIC/WINO REQUIREMENTS, ETC.) THAT ARE NOT INDICATED ON TRUSSWAY'S PLACEMENTS. CONTINUOUS SUPPORT (STUDS, BLOCKING BETWEEN FLOORS, ETC.) MUST BE PROVIDED, BY BUILDER, TO TRANSFER LOADS FROM BEAMS, GIRDERS, HEADERS, ETC. TO FOUNDATION. SEE TRUSS PLACEMENTS & ARCHITECTURAL/ENGINEERING PLANS FOR LOCATIONS OF BEAMS, GIRDERS, HEADERS, ETC. __­1 --o DROP iOP CHORD HIP �2x4l RUNNERS PT.C. TRUSS EXTERIOR V4 UL T ! I � ' k' Scissor Cobh Truss Sc' li f a Truss Scissor Truss f� 4) iI I y L; • d I I vault Line i Bollojo Framed I w0. by others) Vault Noi j •n9 Pbtcrna (beZondZ------- on Interior terior Interior Exterior CAUTION:. EXERCISE CAUTION IN PLACEMENT OF SELECTED HANGERS. TYPE A REFER TO TRUSS PLACEMENT FOR DESIGNATED HANGER AND LOCATION. HANGERS MUST BE ADEQUATELY ATTACHED. SEE HANGER MANUFACTURER'S SPECIFICATIONS FOR INSTALLATION INFO. TRl1SSIMAY• LTD_ CAUTION" REFER TO 8 1/2"01" TRUSS DIAGRAMS FOR UPLIFT FORCES ON TRUSSES EXPOSED TO WINO. PROVIDE INTEMST ADEQUATE ANCHORAGE FOR TRUSSES, AT SUPPORT POINTS, wwo•pusswylco"& AS NOTED ON TRUSS DIAGRAMS. SPECIAL ATTENTION SHOULD BE GIVEN TO ANCHORAGE OF ALL BEAMS & COMPONENTS THAT SUPPORT TRUSSES AFFECTED BY WIND UPLIFT. CAUTION: REFER TO TRUSSWAY'S ROOF, FLOOR AND/OR COMPONENT SPREAD SHEETS FOR A LISTING OF ALL MATERIALS (AND QUANTITIES THEREOF) SUPPLIED BY TRUSSWAY. ALL OTHER MATERIALS ARE TO BE SUPPLIED BY OTHERS. CAUTION: TRUSS GIRDERS MAY CONSIST OF MORE THAN ONE TRUSS MEMBER.MULTI-PLY GIRDERS ARE SHIPPED UNATTACHED FOR EASE OF INSTALLATION. BUILDER/TRUSS SETTER IS RESPONSIBLE FOR REVIEWING 8 1/2"x11" TRUSS DIAGRAMS TO DETERMINE PROPER NUMBER OF PLYS & NAIUNG/CONNECTION METHOD AND MAKING PROPER CONNECTIONS IN THE FIELD. CAUTION: CONNECTING HARDWARE IS NOT INCLUDED IN THIS CONTRACT. CAUTION SHOULD BE EXERCISED WHEN SELECTING CONNECTING HARDWARE. SPECIAL. ATTENTION SHOULD BE GIVEN TO CONNECTOR CAPACITY (i.e. GRAVITY, UPLIFT & LATERAL LOADING), CONFIGURATION & CONNECTION SURFACES. TRUSSWAY IS AN AUTHORIZED SIMPSON STRONG -TIE & USP CONNECTOR DISTRIBUTOR AND WILL BE PLEASED TO QUOTE ALL YOUR CONNECTOR REQUIREMENTS. PLEASE CONTACT YOUR TRUSSWAY REPRESENTATIVE FOR DETAILS. CONTRACTOR IS TO PROVIDE ADEQUATE WATERPROOFING TO PROTECT TRUSSES FROM ANY MOISTURE ACCUMULATION. NON—COMPLIANCE COULD AFFECT THE STRUCTURAL INTEGRITY OF THE TRUSS, REQUIRING REPLACEMENT OR REPAIR. CAUTION: CONTRACTOR TO BE AWARE OF LARGE LINEAR AND CONCEN— TRATED LOADS OCCURING IN BEARING WALLS. IN ORDER TO PREVENT CRUSHING, CONTRACTOR IS TO PROVIDE VER— TICAL BLOCKING IN LOAD PATHS, TO FOUNDATION, AS PER CODE REQUIREMENTS. CONVENTIONAL ROOF BRACING SHALL BE EVENLY DISTRIBUTED ONTO INDICATED "LOAD BEARING" WALLS ONLY. EXCESSIVE DEFLECTION, OR FAILURE, MAY OCCUR IF LOADS ARE PLACED ON WALLS OTHER THAN THOSE SPECIFIED. BOTTOM CHORD IS TO BE CONTINOUSLY BRACED. IN AREAS WHERE A RIGID CEILING IS NOT APPLIED DIRECTLY TO THE BOTTOM CHORD, LATERAL BRACING IS REQUIRED, AT 10'-0" O.C., AT BOTTOM CHORD. WHEN VALLEY TRUSSES ARE PARALLEL WITH SUPPORTING TRUSSES, FIELD BLOCK, WITH 2x4's AT 36"o.c., BETWEEN THE TOP CHORDS OF THE SUPPORTING TRUSSES. NAL STUDS MAY BE REQUIRED AT EACH SIDE OF COMPONENT CONSULT WITH ENGINEER OF RECORD. (E.O.R.) cd h W q TRUSS HANDLING, INSTALLATION AND BRACING DRAWING APPROVAL "*d 9 PROPER PRECAUTIONS SHALL BE TAKEN WHILE HANDLING, INSTALLING & BRACING TRUSSES. TRUSSWAY'S FINAL PREPARATION OF TRUSS DRAWINGS WERE PERFORMED WITH DUE CARE SEE T.P.I. "HIB-91 SUMMARY SHEET" AND W.T.C.A. "WARNING POSTER." FOR ACCURACY AND ARE A DIRECT INTERPRETATION OF THE ARCHITECTURAL PLANS PROVIDED. �� Q TRUSSWAY CANNOT BE RESPONSIBLE FOR THE STRUCTURAL INTEGRITY OF TRUSSES THAT HAVE APPROVAL BY OWNER, ARCHITECT, OR RELATED PROFESSIONS WILL IMPLY THAT TRUSSWAY'S •CJ C BEEN DAMAGED DUE TO IMPROPER HANDLING, STORAGE OR BRACING PROCEDURES. SHOULD DAM- PLACEMENTS, SPREADSHEETS, AND DRAWINGS ARE ACCURATELY DRAWN AND CONCEPTUS TO THE AGE OCCUR, AN ANALYSIS BY A REGISTERED PROFESSIONAL ENGINEER WILL BE REOVIRED & CER- ARCHITECTURAL DRAWINGS. APPROVAL WILL INCLUDE, BUT NOT BE LIMITED TO, DESIGN CRITERIA, (T TAIN FIELD MODIFICATIONS, REPAIRS AND/OR REPLACEMENT OF PRODUCT MAY BE NECESSARY. DETAILS, DIMENSIONS AND QUANTITIES. IN LIEU OF WRITTEN APPROVAL, JOBSITE ACCEPTANCE OF PRODUCT SPECIFIED ON TRUSSWAY DRAWINGS ACKNOWLEDGES APPROVAL. JOB COORDINATION TRUSS DESIGNS DRAWING OWNERSHIP DOCUMENT EXAMINATION THE LOCATION OF TRUSSES IN CERTAIN AREAS MUST BE COORDINATED WITH "ON TRUSSES ARE DESIGNED TO SUPPORT VERTICAL LOADS AS DETERMINED BY OF LOADING, THIS DRAWING, AND RELATED DOCUMENTS, IS THE PROPERTY OF TRUSSWAY AND ARE NOT TO BE REPRODUCED OR COPIED, IN THE CONTRACTOR & ALL RELATED TRADES ARE TO EXAMINE ALL DOCUMENTS IN THIS PACKAGE PRIOR TO ERECTION OF TRUSSES & REFER TO ALL PLACEMENT NOTES & OTHER TRADES (MECHANICAL, PLUMBING, FIREPLACE, ETC.). IF CENTER" SPACING OF ANY TRUSS EXCEEDS DIMENSIONS SHOWN ON TRUSSWAY'S LAY— OTHERS AND NOTED IN CONTRACT DOCUMENTS. VERIFICATION DEFLECTION LIMITS, FRAMING METHODS, WIND & LATERAL BRACING IS THE WHOLE OR IN PART, OR USED FOR UNAUTHORIZED MANUFACTURING, DETAILS, TRUSS INSTALLATION AND BRACING NOTES (YELLOW SHEETS), T.P.I. "WARNING OUTS AND/OR ENGINEERED DRAWINGS, AN ANALYSIS WILL BE REQUIRED AND RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD (E.O.R.). OR IN ANY OTHER EXPLOITATION OF THE ITEMS DISCLOSED THEREIN, COMMENTARY & RECOMMENDATIONS (HIB-91 ORANGE SHEET) AND W.T.CA CERTAIN FIELD ALTERATIONS AND/OR REPAIRS MAY BE NECESSARY. CONNECTIONS OF TRUSSES TO BEARINGS, STRUCTURAL ADEQUACY OF OR IN ANY OTHER WAY DISCLOSED OR USED FOR FURNISHING INFORMATION TO UNAUTHORIZED PARTIES WITHOUT THE EXPRESS POSTER" (WALL POSTER). ANY CONFLICTS, ERRORS OR DEVIATIONS SHALL BE REPORTED TO TRUSSWAY FOR MODIFICATION. NO FIELD ALTERATIONS OR REPAIRS ARE ALLOWED WITHOUT WRITTEN AUTHORIZATION FROM TRUSSWAY. BEARINGS (WALLS, COLUMNS, ETC.) & OVERALL STRUCTURAL INTEGRITY OF THE BUILDING IS THE RESPONSIBILITY OF THE ENGINEER OF RECORD. WRITTEN CONSENT OF AN OFFICER OF TRUSSWAY. NO UNAUTHORIZED FIELD MODIFICATIONS ARE ALLOWED. ROOF DETAILS T- I SHEET GENERAL NOTES NOTAS GENEMLES HAND ERECTION — LEVANTAMIENTO A MANO Trusses are not marked in any way to identify Los trusses no estAn marcados de ningLin modo aue F-I lrl,.��,es 201 ru or Asses 30' or the e frequency or location of temporary bracing. identificlue la frecuencia o localization de los arriostres Lv. I ls�, yj��)o t ess, suppart at Follow the recommendations for handling, (bracing) temporales. Use las recomendaciones de manejo, a! rxl;�k qcarter Point!; Refer to BC51 1-0 Levante de installing and temporary bracing of trusses. listalackIn y arriostre temporal de IDS trusses. Vea el (Q[[& Levame Handlina. Installina & Bracino of Metal Pla BCS1 1-03 Guia Buena P[acVa Data el MaaQQjaAWff& � "", "N () l)� -7� os cuartas Connected Wood Trusses for more detailed v Arricistre de los Trusses de Madera Connectado5 cQn de tra-ro los Placas de Metalpal para mayor inforini information. 1�11 01 'Cil 'S' trusses de 310 Truss Design Drawings may specify Of compression locations Los dibui de disefio de IDS trusses pueden especificar .4-Trusses up to 20' ♦ Pic,", 0 memos. ♦ Trusses up to 30' permanent bracing on individual las localizations de los amostres peirmanentes en IDS Trusses pasta 20 pies Trusses hastar 30 pies members. Refer to the BCSI-63 Summary intembros individuales en compresiciii. Vea la hoja res6merl Sheet -Web Member Permanent 'Web BC51-53 Odra los amostres permarientes v ref g�iaos de fos Reinforcement for more information. All other intembross secundanos (webst para mayor information. El HOISTING — LEVANTAMIENTO permanent bracing design is the responsibility recto de amostres permanentes son la responsabilidad del Hold �a, r' hc, iyositron ��vtli ter�ecl;on unttl temporary ,racingi, ng instalfed and, of the Building Designer. Disefiador del Edificio. As.eto ti cle"Inliq pl)ints, sos;o-oa (0,oa iruss en pnslion coo. la g,tia hasta que, ej imostre, ternpora! ete "Istalado y el A The consequence,.; of imprnper handling, nstallirig and Dearing may be a coflalp-,ti. i-Ifthe',t1ructure, 01 worse, serious personal injury of death Inadecuados, puede. ser !a caida dela esouctilra 0 Do not lift trusses over 30' by the peak. El resuftado de un marlejo, instaiacon yanjostre 10: a6n Peor, fro olhendo�. No evan'r, del Pico los trusses de mAs de 30 pies. Greater than 30' 'As de 30 tiles Banding and truss oliates nay il sharp ecges. Wear gloves virien 1,and, rig arro safezy gia,,SEAS whe" cutting banding. Empaqu,s y plats de mr-tal tienen bordes afirlados. Use guantes y entes p otectones cuando corte l(Y.s ernpaques. HANDLING - MANE)0 lus/e, siaecial care rn wffldy or near power ines a, id hi,Ports. egx"aai en cras cables v1&'m-:os ii, di, aeropucrtol'. HOISTING RECOMMENDATIONS BY TRUSS SPAN RECOMMENDACIONES DE LEVANTAMIENTO POR LONGI3`UD DEL TRUSS Spreader bar for N<,, truss bundles Tagline 4t, YAIv0,4 V LAd arera' bend nc Evitela t'iev6n alefal, &Do ne)". s!"Gre No almacene, unbraced bundles verticalmente Isis upright, trusses sueltos, AN Do rot store on No almaa,,ne en �-y unewen g,uur,,-. terra desugua.l. Toe -in . Tagline Spreader bar 1/2 to 2/3 truss length TRUSSES UP TO 60' TRUSSES HASTA 60 PIES 60' or less Approx. 1/2 truss length TRUSSES UP TO 30' TRUSSES HASTA 30 PIES Locate Spreader bar Attach above or stiffback A 1max. � EFF 1& 17-15 M Spreader bar 2/3 to 314 truss length Tagline TRUSSES UP TO AND OVER 60, TRUSSES HASTA Y SOBRE 60 PIES BRACING - ARRIOSTRE Peter to tdwj, and TerrPvrary!3.fac!ng for more lliformation. Vea e ru$y YArInQ,51tt TertflIdral Data mayor informao6n. 0 Do Nafk on unbraced trusses. No cainfnc en trusses sueftos lgi­d' brace5 foe 41's, trus" !�!�r,'�%;rh oularcivis of top chord lemoofary n'aci, gi, C�., a! riosl!�.,s d4n tiara el p le, , a e eel can d "aaa d<- as f'ia5 de Lmotres laterae's d I &upenof, Brace first truss well before erection of additio nal trusses. Top Chord Temporary Lateral Bracing (TCTLB) min. BRACING FOR THREE PLANES OF ROOF EL ARRIOSTRE EN TRES PLANOS DE TECHO 17h This braong method s for aii trusses exceal 3Y2 and 4x2 par fief s�_ e� chord tr" sS, E, s od t Iste rne�todo fre arnostre, e- Para t o trusses exce,, o I.,,, sses de cuerdas iaraliz'as 33,x It, i' 1) TOP CHORD — CUERDA SUPERIOR Truss Span Top Chord Temporary Lateral Brace (TCTLB) Spacing Longlitucl de Tramo Espaidamiento del Aniostre Temporal de la Cuerda Superior Up to 30' 10' D.C. max. Hasta 30 pies 10 pies m6ximc, 30' to 45' 8' D.C. max. 30 a 45 pies 8 pies mSximo 45' to 60' 6'o.c. max. 45 a 60 pies 6 pies mSximo 60' to 80' 4'o.c. max. r 60 a 80 pies* 4 pies m6ximo :ConSU:t a Professional Engineer for trusses longer than 60'. Consu te a un ingeniero para trusses de mas de 60 pies. See BCSI-K for -1 C7L3 opl,o­, Vea el BCSI-B2 parlasopoorieis de . TCTLB. f rroPr I,5f U, Sul Yr>-1�.r15he Qalblkl End Flarli'll vea el K51-55 - 0"2 1 te,msnai de un Kr; a, leas agaa* N diagonai h 13e,es, Snit hist fiie, "'usse" 'wr&, SDacer peces, the", add c,aqona'_, Re%P,-al, P'oces,; on gioup's of four unt"I aJ­,nisi Soti r`lr(` Srt j nst al 1os n"o Pei me, r os I russes c. sD r 7 rE qo I al? than ona,7es, Repita e te pi-oceofirniento en qujix,tio hasta que tondos (s tnisses ester, insialados, 2) BOTTOM CHORD — CUERDA INFERIOR Lateral braces 2x4x12' length lapped over two trusses. , 10'-15' max. Diagonal braces every 10 truss spaces (20' max.) Some chord and web members not shown for clarity. 3) WEB MEMBER PLANE — PLANO DE LOS MIEMBROS SECUNDARIOS Web Diagonal braces every 10 truss spaces (20' max.) 10 max. same spacing as bottom chord Some chord and web members not shown for clarity, lateral bracing DIAGONAL BRACING IS VERY IMPORTANT iEL ARRIOSTRE DIAGONAL ES MUY IMPORTANTE! BRACING FOR 3x2 AND 4x2 PARALLEL CHORD TRUSSES EL ARRIOSTRE PARA TRUSSES DE CUERDAS PARALELAS 3x2 Y 4x2 Ref", to Bc,$J-87 Maximum lateral brace spacing 10' o.c. for 3x2 chords 15' o.c. for 4x2 chords iii) Diagonal braces of every 15 truss spaces (30' max.) ni`oiiiialuori, ve li ,a f:i resurn, ae The end diagonal truss( de brace for cantilevered pars llela5 Uara mayor trusses must be placed Lateral braces rifc,"maci6n, on vertical webs in line 2x4x12' length lapped with the support. over two trusses. INSTALLING - INSTALACION i � 71 Tol,,ranc,s for Oul-or Pfame. Tole,ancos Para 'Jera de-Pianc, iy-j lvtu Bow Max. Truss Bow Length --in or �_, 12.6 ��_j — Length 3/4 _j Length Max Elo. 7/8' 14.6' T 01 D/50 0 (ft.) 1 16.7' o"erances f L01 1-1/8, 18.8' 1/4" 11 Tolfas par 1/2" 21 1-1/4"l­/4' F 208' ,api,, Fue!,a de Prorerada. 1-3/8' 22 9T Plumb 3/4" 3' 1 bob 1 - 4' 1-1/2' 25.0'1 1-1/4" 5'_ 1-3/4' 1 29.2'- D/50 max 1-112" 6' 2' 1 2:33.3- 1-3/4" 7' 2" z 81-1 CONSTRUCTION LOADING CARGA DE CONSTRUCCION lX Do not proce+wrth all hracvrlg is WK.urejy Maximum Stadc Height and Pfopxdy in otacin. for Materials on Trusses Nc prcy.eda ,..on a (or.strUca6c hasta que. os an lostree, 110111"rial Height (h) e_ _'n crrixacxs: er) to, ma acroprada y sf`(�Rlea. Gypsum Board 12" Plywood or OSS 161, air Shingles 2 bundles role Block 8" Tile 3-4 tiles high Do -rof exce��d maxirrum Slack. heglits� Peter "', FC51 1�41 ASPI S�Jlnriijfy 5riect Con5lrua;on Loa�,ing for more nformatlon. con, No ey(eda 'as mJxlmas afturas recomendacias. Vea el clay OX-51 para mayorn:i;rma for D not (,,ve,-,k.,,ad snia'! grr, is or smete (11 -P g t usses, No Peque,ios gruUzos o tuusse� ridividual-s lai rl oadti o'e", ifs :niSses as P_ssiblf�_ cc,& as carr-is ta,"r rfses co ✓ sfa CIE C:r oao� ovi�, tica,�rg vralii- rlvooue, rargas sibre as, aredes soc:o,Iariles, I. ALTERATIONS — ALTERACIONES . ..... Refer to Bi-51 B5 sv.rnierlal y 5teet - Ttijss DaMirge, 3,90,fte MQdJfl(_a`jQf15 and li-,15,tla,31"3,t)o�,iErrQ,15, 0'a ell ie_,sl)rrLtn �CSJ Oz.. J)ahQ5 vQ trlr55C5, MC4 K. I a- i�l Qord Y, jr.Staj�_c Doncir;cjt, altef� of drill any ,tructirat member of a tr.us.s six."cificaliy per mitired by Truss Design Drawing. No crrte, aftere, o Pertorc. ning6n miemtro estructurall de los trussr,s, a men due estin l.F pefmitido er, ei jo de! dlseiio de' in ss. "nusse", -hat have, neen eDvlr1f,add d durilic constructOn or elterfKi vishout the Truss Manufacturers prior aprircival may ren(A-., the TrusstuanUfaCtureis warranty nrill and vord. Tr,j,.,,.,i­ q, e se ha,- r4)breca- aflo curante la con Sir jf-c-6,1 o hay i silo afterados sin una autonzac16r, do Fahricante, do Trusses, pueden reduer o eNminar la gatantfa del Fabricante de Trusses. NOTE: The Truss Manufacturer and Truss Designer must rely on the fact that the Contr.-tor and — operator (if applicable) are ca- pable to undertake the work they have agreed to do on a parMular project. The contractor should seek any required assistance regarding construction practices fn:,i,, a competent party. The methods and procedures outlined are intended to ensure that the overall conshtcMdri, tectirwqu" MpIOVW will put floor and roof trussesito place SAFELY, These reconinnerydrations for handling, rnst3l" and bracing wood t— are based upon the collective experience of leading technical personnt in the wood truss rdustrii, but ­t, due to the nature of responsibilities imolved, be presented only as a GUIDE for use by a qualified Building Designer or frectweIrstallation contractor. It is not intended that these re—datkins be interpreted as superior to ^ design spwif<abon (provided N either an Architect, Engineer, the Burpieng Designer, the Erectionanstsliation Cont—of or otherwise) for handling, installing &to bating wood busses and R does not preclude the � of other equivalent rreWds for bracing arid providing stability for the wells and colurrins, as may be determined by the truss Erection/Instagatm Contrik:tor. Thus, the Wood Truss C-1 of Amerka, and the Truss Plate Institute expressly disclaim any respon,ilpiKy for damages ansing from the use, application, or reliance on the �wtinendatrdns and Wornati.n contained herein. & 'A -n ih, WOOD TRUSS COUNCIL OF AMERICA TRUSS PLATE INSTITUTE 6300 Enterprise Lane - Madison, WI 53719 218 N. Lee St., Ste. 312 - Alexandira, VA 22314 608/274-4849 - vinwAy.woodbrus,s-corn 703/683- 1010 - —.txst.org B1WARN11x17 20050501 (3) — (0. 148 x 3 114" P—nail TOE —NAILS OP & BOTTOM CHORD CONNECTION. NAILS THROUGH BACK SIDE OF YRDER INTO END GRAIN OF (ONO TRUSS ARE NOr ALLOWED) Ca 3) - (0. 148 "x3 1/4 " P-nail TOE -NAILS @ TOP d, 'OTTOM CHORD CONNECTION FOR 'f IR " GIRDER NO (12) NAILS ALONG VERTICAL END WEB OF YR " GIRDER INTO THE HIP GIRDER TRUSS. 2) - (0. 148 "x3 1/4 " P-nail TOE -NAILS @ OP & BOTTOM CHORD CONNECTION. 0 R" ?DER TYPICAL HIP SET NAIL11 OPEN FACE I Allowable Holes for Uniformly Loaded Beams , , 3" minimum 1/3 depth diameter maximum 1/3 depth-V131" -- ,,Allowed Hole Zone 1/3 depth# � Allowable Hole Zone 1/3 span 1/3 span 1/3 span - ' r lyl Cutting, notching or drilling 1. This hole chart is for typical beam applications only, and covers uniform loads and span holes are N07 allowed, conditions provided in this brochure. except as noted. 2. No square holes are allowed. 3. For other hole configurations, contact your design professional or supplier for assistance. Multiple Member Connections 3 -11Z' 2':E 1 2Pc.1-3/4" I 2" fq4- 1-314" x 2 5-1/4" 5-1/4" 5-1/4" 1. Specific gravity for nail and bolt design is 0.44. 2"L 2. For 2 rows - 16-d nails @ 8" o.c. use 540 plf, 6" ox, use 720 plf and 4" o.c. use 1080 3 Pc. 1-3/4" olf. For 3 rows - 16-d nails @ 8" o.c. use 810 plf, 6" o.c. use 1080 plf and 4' o.c. use 2"T 1620 plf. 3. For 2 rows - .131" dia. gun nails @ 8" o.c. 1-374'x3 1-3/4"+3.5` 1-3/e-x3 use 428 plf, 6" o.c. use 570 plf and 4' o.c. use 855 plf. For 3-rows .131" dia. gun nails @ 8" o.c. use 638 plf, 6" o.c. use 850 plf 7" 7" 7" and 4" o.c. use 1275 plf. 4, For 1/2" bolts spaced 8' o.c. use 1125 plf, 2" 6" o.c. use 1500 plf and for 4" o.c. use 3 Pc. 1-3/4" 2250 plf. (BoR only) I 5. The beam must be sized to cart' the applied load, the connection can then be —I checked for adequacy. 1-3/4'xe 3.5'.2 —_1-3/1-12+3.5" -�—�-5 6. For 3 piece members, nailing is specified for both sides. for Side -Loaded Beams 7. Values listed are for 100% duration. Increase 15% for snow loaded roof condi- tions and 25% for non -snow loaded roof conditions. 8. All nail and bolting requirements use the 2001 edition of the P)DS® as a guideline. NDSO does not purely apply to this con- nection problem. Bolt design assumes a worst case mode I single or double shear failure. Nail design assumes a worst case mode III failure. 9. For beams greater than 7" wide see a design professional for the bolting and loading requirements. 10. Screws cqn be used in place of bolts as long as the screw capacity is identical or greater than the 1/2' bolt capacity. See screw manufactuer literature. Specification Guide 1.0 GENERAL MASTER PLANK® is a laminate construction of spruce veneers procured from forests managed and certified under the Finnish Forest Certification System audited by BVQI (Bureau Veritas Quality International) according to the IS014001 environ- mental standard and the ISO 9002 quality standard. It is composed of various qualities of veneer arranged to obtain optimum utilizes - lion of each veneer to develop maximum strength and reliability. All veneers are oriented with the grain parallel to the long dimension of the billet, and is commonly referred to as Laminated Veneer Lumber (LVL). 1 2.0 3.0 INTENDED USE This product is intended to be used as beams, joists, lintels or rafters under dry conditions of use, and for scaf- fold plank, staging, bleacher seats, cross arms, ladder rails and other industrial applications. DIMENSIONS AND COMPOSITION MATERIAL 4.0 Veneer Plies Face, back and inner plies are all of the same species and meet Pan European Forest Certification requirements. 4.1 Species Norway Spruce (Picea abies) 4.2 Grade The grade shall not be below Grade C, per American Product Standard PS 1. 4.3 Thickness The thickness of each veneer shall be nominal 3.0mm (0.110'J. CONSTRUCTION 5.0 Glue Bond Requirements The glue shall meet or exceed American Product Standard PS 1-Exterior Type, 6.0 Grain Direction All veneers shall be oriented with the grain parallel to the long dimension of the billet. 7.0 Veneer Joints All individual veneer joints shall be scarfed and staggered, with a distance between joints of not less than 4" (10.16 cm). 8.0 Tolerances Width < 8" (200 mm) t 1/16" r..,F.�.�1•^,� a�:(�oo�rnr,���,��'r�soo txlrr�)�,�it;`Vf8�3 a;>nrrp�.�,�" > 24" 600 mm f 0.5 % Bearing Information 4 / Bearing at Concrete Wall Protect wood from direct contact with concrete per code requirements. Consider concrete and masonry connectors for this type of application. MANUFACTURE &0 Finished Product 9.1 Widths Widths shall be cut within tolerances given, and with square clean edges, for each order. 9.2 Lengths Lengths shall be cut within tolerances given, and with square dear edges, for each order. 9.3 Surface Surface may be sanded or unsanded as required by order. 9.4 Surface Surface (face) veneer may be grade A (clear) if requested. 9.5 Surface To enhance dimensional stability, seal coating can be provided upon request QUALITY CONTROL 10.0 MASTER PLANK is manufactured under the ISO 9001 quality certification system. Quality control shall be under the supervision of the Technical Research Centre of Finland, Helsinki, Finland. IDENTIFICATION 11.0 MASTER PLANK 2 �P Per code H top Bearing for pole is not continuous „over header. Door or Window Header Trimmers. See page 4 item $5, and following 1/2, Plywood tables for minimum or OSB fiber number of binuners. 5 Bearing at Wood or Steel Column \ Verity required bearing area. M, YTr MW, W TrmCon sn LaFaaon Aoen,<,. z9ve F..z.aE LnwaU7ED vENEFR WNBEA Fl n nforest ManuAonr.d FW.Ab l USA In Fwand E�vb. d wood 0M.$.n Minimum of 2 rows 16d (3 1/27 nail 12' o.c. Minimum of 3 rows 16d (3 1/27 nails at 12- o.c. for 14", 16' and 18" beams. Multiple pieces of Master Plank can be nailed or bolted together to form a header or beam of the required size, up to a maximum width of 7'. Connection of Multiple Pieces of Top -Loaded Beams For side -loaded multiple member beams, see table on P9. 3 1 Feb 24 06 08:59a P. e GR4PWID* INC. February 23, 2006 Dan Florian City of Sanford Building Official 1'0 Box 1788 Sanford, F1 32772-1788 RF.: Residence at 2437 Marshall Ave. Sanford, Fl Dear Mr. Florian: We are hereby requesting a 90 day time extension for the permit application for this project due to the extensive amount of time required to procure the septic tank permit from Seminole County after the application was submitted. Thank you for your consideration in this matter. Regar , Ci - uggin� 129 ROBIN ROAD - AETAMONTL' SPRINGS, FLORIDA - 32701 PTION1_;: 407-599-4711 - FAX- 407-599-4733 Fgw,. 4, 06 00:59a r STATE: Oh' l'LORIDA y DE PARTMLNT OF HEALT11 ti ONSITE. �;EWAG*L TREATMENT AND D.T. ;PO3AT, SYSTEM * CONSTRUCTION PERMIT CONOTRUC:TTON PERMIT FOR: ( X j Nl?w ryat(vm ( ) Existincl Sy stem ( ) Holding Tank [ ( ) Rc.paiz [ )Abdndonm�nt. [ ) T'omporiry ( Un APPLICANT: Metro Devolopmont A(:FN`f: 00-0000, N/A PROPRR'fY OTRLET ADDRESS: 2437 Marshall Sanford FL 32771. p.9 CENTkAX II: 59-S2-09280 DATE PAID: Fr•T' PAIL) $ RECEIPT C�'1'U: NBR 05-927E—NW Irtnov,it,iv? Other LOT: 5 BLOCK: 5 ,'UBMVISION; Dreamwold ( Sect ion/ Town^))ip/Range/ Par.er:1. No.] PROPERTY ID 1): 36-19-30-524-0400-00 (Ok '(AX ID NUMBER] Sy:'ChM MUST DE CONSTRUCTED IN ACCORDANCE WITH SPr(.**r :'FCA9'):UNS AND STANDARDS OF CHAPTI?R P4h.-ti, i HC DE17ARTME•NT APPROVAL OF SY:'I'EM DOES NOT GUARANTEE SATISFACTORY PERFORMANCE FOR ANY SPECIFIC TIME PFRT.OD. ANY CHANGE IN MATF.RTAT, FACTS, WHICH SERVED AS A 13ASI3 FOR ISSUANCE OF TILTS PF,,RMTT, REQUIRE: THE APPT,T.CANT TO MODlt'Y THE PERMIT APPT.T.CATION. SUCH MOI)TFTCA'i'IONS MAY RLSULT 1N ThI6 PERMIT BEING MAUL NULL AND VOID. TSSOANCE OF THIS PERMIT DOT,0: NOT EXEMPT THE APPLICANT FROM COMPTJANCL WITH OTHER FEDERAL, STATE OR LOCAL PE• RMTTTTNG REOUTRED FOR PROPERTY DEVRT,OPMENT. SYSTEM DESICN AND SPECIFICATIONS '1. ( 900 j 1on:', SEPTIC TANK A ( 0 ) Cal lon^ N [ 0 1 GALLONS GREASE TN'1'k;1aCT1--PTOR CAPACITY K (, 225 ] (-.AI,I,ONS f)o ;JNU TANK CAPACITY ( 10p D R A I N F I E L D [ 462 )SQUARE FEET ( 0 J SQUARF. FRET TYPE; SYSTEM: CONFI(I)RATION: PRTMAKY URIIINFIELD SYSTEM SYSTEM mound bed MULTI-CHAM313RE;U/iN SERTT.S: [ Y MULTI-CHAMRFREIVIN SERIES. (Y J GAT LONS @ [1;3 ) DOLES PF:R 24 11RS 11 PUMP,-[ 1 1 LOCATION '1O BENCHMARK: Orange Dot Canter of Marshall Ave. Front l,ot 5 ELEVATION OF PROPOSED SYSTEM ' 11.'E ( 4.30 ) ( INCHES ) [ ABOVE ) BE• NCHMAPX/REFERE• NCE POINT BOTTOM 01i' URA1NFIELD TO DE [ 22.30 ) ( INCHES ) ( ABOVE j 13ENC11MARX/RFe'h;RE;NCE POINT FILL REOUIR70: ( 32.5 ) INCHES GXC)AVATTON REQUIRED: [ 36.0 1 INCHF..7, O'I HE:R REMARKS The licensed contractor installing the aystem is responsible for installing the minimum category of tank in accordance with s. 64E--6.013(3)(f), FAC. A minimum cat 3 tank is required with no more than 18 inchev of cover soil. Condition apply only to the area inveetigated.if other conditions are encountered dunning construction tbo eng should bo notified inanediately.(1) Sleeve potable water lines within 10 'feet of drainfield. Loavo uncovered for inspection. (4) Private potable wolly must be 75 ft from system, non -potable 50 ft/locate and mark wells. (9) Maintain 75 feet from surface water. (22► Spoil material from drainfiold repair shall not be used in system repair and shall be disposed of prior to inspection. If replaeoment drainfiold is going back in existing location, total removal of old drainfiold, regardless of dopth must be accomplished. (23) This office will conduct a site evaluation which will be conducted at time of inspection to confirm that soils found below the b.o.d. are conointant and in compliance with CH 64E-6 F.A.C. In addition any discrepancies will be corrected and this office will charge a fee of "PECIFICATIONS HY: Law, Donald 42 A!'PROVE•D BY: Dove, Kim � ��,1/�/ •�!)d ij� 1 DATE T; U):;U: 12/22/05 TTTT.F.: P 1, TITLE•: EH Suporvisor Seminolo Cl!D EX1'I[�TTON t)H'PI 6/22/07 UK 4016, W)t (Q"v4tes provious edition;; whit;h m,ay not be usuu) (Stork Number: 5744-001-401.6-0) »� •_n �r 11 Fagc 1 of F&Jb ?4. 06 08:53a p.10 57'.00 for a site evaluation.No portion of mound water she can drain onto adjacent lot. 12/23/2005:P.E. Design Required. Maximum Dose Cycle a 6 x per day. , Ono Pump Required. Dose Entire Grainfield each cycle. Pumps must be certified as suitable for distributing sewage effluent. SPECIrICAT:I:UNS BY: Law, Donald TITLE: AITROVED HY: Dove, Kim 'TITLE: ER Supervisor Seminolo CHD DATE, .ISSURD: 12/22/05 EXPIKATION DATE: 6/22/07 u11 401c,, 03/97 (0b:;9letc3 orcv.Wuj edir.'_w, which wv not by used) Numbor: n144-0n1-4010, 01 (it ` Feb a% 06 02:18p p.2 1' a STATE OF FLORIDA '••; ♦ TJFPARTMF.NT OF HEALTH ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM CONSTRUCTION PERMIT ,•Y•� CONSTRUCTION PERMIT FOR: ( X ) New System ( )EXiSLirlt) SyS�em ( )Holding 'tank f [ jRopair ( )Abandonment ( )'Temporary [ Un APPLICANT: Metro Development AGENT: 00-0000, N/A PROPERTY STREET ADDRESS: 2431 Marshall Sanford FL 32771 C.'ENTRAX J[: 59-S2-09280 DA'1'L•' PA U: FFF PAID $ RMCrrPT 05--9270—NW InnovatiVf: Ot.hr`T LOT: 5 r .00K: 5 SUDDIVISION: Droamwold (5e! Lion/'1'r�wr�rship/Kunt)�/1't�rcrsl No. J PROPERTY 10 #: 36-19-30-524-0400-00 (OR TAX ID NUMBER) SYSTEM MUST BE CONSTRUCTED IN ACCORDANCE WITH SPECIFICATIONS AND STANDARDS OF CHAPTER 61E-6,FAC DEPARTMENT APPROVAL OF SY ')'L;M DutS NOT GIIARAN'I i, SA'.PT FACTORY 11K), I1-'ORMANCE FOR ANY SPECIFIC 'TIMI, PERIOD. ANY CHANGE IN MATERIAL FACTS WHICH SL KV};D A;• A IA;:I$ FOR ISSUANCE OF THIS PERMIT, REQUIRE TUTS APPLICANT TO MODIFY T1116 PERMIT A121'L1CATION. S:IJCH MODIFICATIONS MAY RESULT IN TAIL' PERMIT BEING MAUL; NULL AND VOID. ISSUANCE OF TVIS PERMIT DOGS NOT EXEM1"1' THE AL'i'L1CANT FKOM COMPJ,TANCF WT.TR OTIIER FEDERAL, STATE OR LOCAL PERMITTING REOVIKED FOR PROPERTY DENF.T.OPMENT. >Y:i'1'LM DESIGN AND SPTECIFICATIONS T [ 900 ] C.i i 1 onn SEPTIC TANK MULTI-C:IIAM9IT RED/IN .SERIES: (y J A [ 0 ] (,7:,I I on re MULTI-CHAMHER60/1N "ERIGS: [ X J N [ 0 JGALLONS GREASE INTERCEPTOR CAPACITY K [ 225 ) GALLONS DOSING TANK CAPACITY [ 16D ) GALLONS P [.kj ) DOSES PER 24 HRS 11 rUMP; ( 1 ) D It A 1 N F I L•' L D ( 462 JSOUARE FEET ( 0 ) SQUARE 1'L:L;T TYPE SYSTL:M: CONFIGURATION: PRIMARY DRAINFIELD SYSTEM mound bed LOCATION TO BENCHMARK: Orange Dot Center of Marshall Ave. Front Lot 5 ELEVATION OF PROPOSED SYSTEM SITE ( 4.30 ] f INCHES ) ( A30VE j DENCHMARK/k►..)rPkF.NCF• POINT BOTTOM 01' DKAINFIL'LD TO 81: ( 22.30 ) [ INCHES ) [ AI30VE ) DENCfIMARK/RGCERL:NCE POINT FILL REQUIRED:[ 32.5 )INCHES EXCAVATION REQUIRED: 1 36.0 ] INCIII O''HF.k Rh,*MARKF:: The licensed contractor installing the system is responsible for installing the minimum catogory of tank in accordance with s. 64E-6.013(3)(f), FAC. A minimum cat 3 tank is required with no more than 16 inchee of cover soil.Condition apply only to the area investigated.if other conditions are encountered durning construction the eng should be notified immediately.(1) Sleeve potable water lines within 10 feet of drainfiold. Leave uncovered for inspection. (4) Privato potablo yells must bo 75 ft from system, non -potable 50 Pt/locate and mark wells. (7) Maintain 75 feet from surface water. (22) Spoil material from drainfield repair shall not be used in system repair and shall be disposed of prior to inspection. If replacement drainfield is going back in existing location, total removal of old drainfiold, regardless of depth must be accomplished. (23) This office will conduct a site evaluation which will be conducted at time of inspection to confirm that soils found below the b.o.d. are consistant and in comp"aneo with CH 64E-6 F.A.C. In addition any discrepancies will be corrected and this office will charge a foe of SPECIIICATIONS DY: Law, Donald APPROVED BY: Dove, Kim e /yu DATE ISSULD: 12/22/05 TITLE: 1) e TITLE: EH Supervisor Seminole ciin LXPIRATION DAT' :: 6/22/07 Uh 1016, 03/97 (Ub3olctei previous editions which may not; Ix u3k:u) Citock N%Uw4r: 5744 001 401E 0) Ioc .J� w�•c I:r, r•7t 1'a•.1 �..' 1 CSC Z Feb „, l 06 OZ: 18p P.3 + $75.00 for a site evaluation.No portion of mound water she can drain onto adjacent lot. 12/23/2005:P.E. Design Required. Maximum Dose Cycle m 6 x per day. , one Pump Required. Dove Entire Drainfield each cycle. Pumps must be certified av vuitable for distributing sewage effluent. SFCCI[.CATIONS BY: Law, Donald TTTT.F: AFPROM) L4Y: Dove, Kim TITLE: EH Supervisor Seminolo DATE .TSSUED: 12/22/05 D11 4016, 03/77 (Ut15Q1eCc6 PLUVIOUY N.d.1t10n5 which imy nnr hp n.gan) 0,L,�vh Mm,k, r: 474n 661 40I.G 01 1vvWu Whu 7V1V-11 EXP1 FtkT1ON DATT'.: 6/22/07 010 NL�t�t 1 ul 2 J CITY OF SANFORD PERMIT APPLICATION _ (Jl Permit # : r f Date: Job Address: 2437 Marshall Avenue Sanford Florida Description of Work: Construct Single Family Residence / J>/� '� > C..L/X.r Gxg Historic District: Zoning: SR-1 Value of Work: $ %� �- Permit Type: Building X Electrical Mechanical Plumbing Fire Sprinkler/Alarm Pool Electrical: New Service — # of AMPS Addition/Alteration Change of Service Temporary Pole Mechanical: Residential Non -Residential Replacement New (Duct Layout & Energy Cale. Required) Plumbing/ New Commercial: # of Fixtures # of Water & Sewer Lines # of Gas Lines Plumbing/New Residential: # of Water Closets Plumbing Repair — Residential or Commercial w Occupancy Type: Residential X Commercial Industrial Total Square Footage: f Construction Type: Block # of Stories: 1 # of Dwelling Units: 1 Flood Zone: X (FEMA form required for other than X) Parcel #: 36-19-30-524-0500-0040 (Attach Proof of Ownership & Legal Description) Owners Name & Address: John B. Muroski 732 Keaton Park -way, Ocoee, FL 32761 Phone: 407-654-1594 Contractor Name & Address: Metro Development Group, Inc., 129 Robin Road, Altamonte Springs, FL 32701 State License Number: CBC1251%5 Phone & Fax: 407-599-4711 Contact Person: GaryHuggins Phone: 407-468-9217 Bonding Company:__ Address: Mortgage Lender: BB&T Address: 255 South Orange Avenue, Orlando, Florida 32801 Architect/Engineer: Distinguished Designs/Rod Vermillio: Ken Ehlers, P.E. Phone: 407-772-7768 / 352-383-0760 Address: 216 Markham Woods Rd., Longwood / 6034 Falconbridge Place, Mt. Dora Fax: 407-772-2162 / 352-383-8650 Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, and AIR CONDITIONERS, etc. OWNER'S AFFIDAVIT: 1 certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. y Acceptance of pe 'verification that 1 will notify the owner of the property of the requpcents of orida Lien Law, FS 713. wig--12 — t wnerl t'se t 'ontrac is Name � �-- '' gn of otary- tale of Florida Date igna re of Not te of Fiatida roe a JUUA ANN NIEMANN .0,1tV PO,, e I HY 0�l1,diS8!0N S DD 299770 � th- , IN iEMANN * r F t y r I ,,� March 27, 2008 er//�ge` Person ly Known to Me or Contractor/Agent i Personal I Known =Y�t �r bonded Thru Budget Notary Services I �' h Produced ID APPLICATION APPROVED BY: Bldg:__ Zoning: (Initial & Date) f Initial & D te) (Initial & Date) (Initial & Date) Special 21�3L'11�1~ FEES SCE C'i cad :' 4 6-(5 .... 1. ... .. •.1.. - .1 •.. •.... 1. ". .1 - .1 YII .1 YII 11 .4. 1 44� THIS INSTRUMENT WAS PREPARED BY AND SHOULD BE RETURNED TO: LYNNE R. WILSON, ESQUIRE huffield, Lowman & Wilson, P.A. Post Office Box 2087 Orlando, Florida 32802-2087 PERMIT NO. MNHYRNNE MORSE, CLERK OF CIRCUIT COURT SEMINULE COUNTY BK 05827 FAGS 0557-0559 CLERK'S it 2005125557 HELUHUEU 07/26/2005 0214309 PM REWHUINU FEES 27.00 RELURUED BY D Thomas `�.\\0\j`,k\ MpRv n�\r. • C`�RK OF CO��Y. gEM\N TAX FOLI(7' °sPJ p t NOTICE OF COMMENCEMENT STATE OF FLORIDA COUNTY OF SEMINOLE The undersigned hereby gives notice that improvement will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement: Description of property: SEE EXHIBIT "A" ATTACHED HERETO AND INCORPORATED HEREIN BY THIS REFERENCE 2. General description of improvement: construction of seven single-family residences 3. Owner information: a. Name and address: JOHN B. MUROSKI 732 Keaton Parkway Ocoee, Florida 32761 b. Interest in property: fee simple c. Name and address of fee simple title holder (if other than Owner): 4. Contractor (name and address) METRO DEVELOPMENT GROUP, INC., a Florida corporation 129 Robin Road Altamonte Springs, FL 32701 a. Phone Number b. Fax Number (optional, if service by fax is acceptable). 5. Surety: N/A a. Name and address: b. Phone Number c. Fax Number d. Amount of bond: $ (optional, if service by fax is acceptable). S \CUENTS\B\B3&n1188 Metro Development Group, Inc\l 188aip.wpd 6. Lender: (Name and address) BRANCH BANKING AND TRUST COMPANY 255 South Orange Avenue, Suite 112 Orlando, Florida 32801 a. Phone Number (407)563-4017 b. Fax Number (optional, if service by fax is acceptable). 7. Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by Section 713.13(1)(a)7., Florida Statutes: (Names and addresses) a. Phone Number b. Fax Number (optional, if service by fax is acceptable). 8. In addition to himself, Owner designates CATHERINE W. MONTGOMERY, Vice President of BRANCH BANKING AND TRUST COMPANY, 255 South Orange Avenue, Suite 112, Orlando, Florida 32801 to receive a copy of the Lienor's Notice as provided in Section 713.13 (1)(b), Florida Statutes. a. Phone Number (407) 564-4017 b. Fax Number (optional, if service by fax is acceptable). 9. Expiration date of notice of commencement (the expiration date is one year from the date of recording unless a different date is specified): /J (Owner) STATE OF FLORMA COUNTY OF MUROSKI, Individually The foregoing instrument was executed, sworn to and acknowledged before me this July 02 , 2005, by JOHN B. MUROSKI, Individually. Nuu..................................... (SEAL MMY E SHUFFIELD 0µsitu t Corms 000352257 Mcw�I -. �ieId Name of Notary Public (Typed, Printed or stamped) Personally Known OR Produced Identification ✓ Type of Identification Produced: nrl Ve,l'J l it t_ rac- SACL:ENTS\B\BB&TU 188 Vetro Development Group, Inc\l188aip.wpd EXHIBIT "A" Legal Description Lots 1, 2, 3, 4, 5, 6 and 7, in Block 5, of 3`d SECTION DREAMWOLD, according to the plat thereof as recorded in Plat Book 4, page 70, of the Public Records of Seminole County, Florida. SACLIENTS\13\1319&7U 188 Metro Development Group, Inc\] 188legal wpd Seminole County Property Appraiser Get Information by Parcel Number Page 1 of 1 -AkCLL UL I'Ail! r, 4 17 117.0 17.0 3.0 17 4 17 3 00101a 18.0 to ,s �<! _ to ❑AVID JOHNSQN, CFA, ASA .'4 1 `'� 11 Aa' PROPERTY ," „ 1i - '� t' �12.0 `� 1' �11A is _ APPRAISER 5 1'y ; 4 5 5 V g ,9 SEMINOLE COUNTY FL. i{3 + 17 3-{j 17 4 r,? 3 17 3 ' 17 y 11.019.0 1101 E. FIRST ST 1218 ,1.O .ii 1.019.0 1 18.0 SANFORD, FL32771-1468 407-665-7506 _9 1 _ 24 '+ 3; 031.0 15.0 11A �a a 1 0 } 1 2005 WORKING VALUE SUMMARY Value Method: Market GENERAL Number of Buildings: 0 Parcel Id: 36-19-30-524-0500-0040 Depreciated Bldg Value: $0 Owner: MUROSKI JOHN B Depreciated EXFT Value: $0 Mailing Address: 732 KEATON PKWY Land Value (Market): $58,8 City,State,ZipCode: OCOEE FL 32761 $0 Ag: $0 Property Address: 2429 MARSHALL AVE SANFORD 32771 Land Value Just/Market Value: $58,800 Subdivision Name: DREAMWOLD 3RD SEC Assessed Value (SOH): $58,800 Tax District: S1-SANFORD Exempt Value: $0 Exemptions: Taxable Value: $58,800 Dor: 00-VACANT RESIDENTIAL Tax Estimator 2005 Notice of Proposed Property Tax SALES Deed Date Book Page Amount Vaclimp Qualified 2004 VALUE SUMMARY QUITCLAIM DEED 07/2005 05827 0522 $100 Vacant No 2004 Tax Bill Amount: $916 WARRANTY DEED 04/2005 05714 0557 $185,000 Vacant No 2004 Taxable Value: $44,688 WARRANTY DEED 03/1982 01388 0895 $64,000 Vacant No DOES NOT INCLUDE NON -AD VALOREM WARRANTY DEED 01/1973 00982 1964 $8,000 Vacant Yes ASSESSMENTS Find Comparable Sales within this Subdivision LAND LEGAL DESCRIPTION Land Assess Frontage Depth Land Unit Land PLATS: Pick... • Method Units Price Value FRONT FOOT & 3RD SEC 240 136 .000 250.00 DEPTH $58,800 D EAMWOLD PB 4 PG 70 NOTE: Assessed values shown are NOT certified values and therefore are subject to change before being finalized for ad valorem tax purposes. "* If you recently purchased a homesteaded property your next ear's property tax will be based on JusUMarket value. http://www.scpafl.org/pls/web/re_web.seminole_county_title?PARCEL=36193052405000... 9/28/2005 1 20' Lai= MARSHALL AVENUE 0 20 40 x 60' TOTAL R1W x .0 F X--CUT 252.50-(MM) SIR LOT 4 ch (x) ut O I. — CA) C) 0 SIR S 00`26'27" .0't, I 11.00' r! 60.00, -2&M) SIR L0 If C3) 0I ch c), T I.00, PORCH CD PROPOSED I cz RESIDENCE: I I I — UT �2 CD .0,1W 1.00' ILJ O (Y 0 u 0 Ll- LA C� r1i w x rL to t 7' LIE S 00"26"27" E 60-00'(R&M) LOT 16 SIR 1-01' 6 NOTE: BOUNDARY SURVEY AND SITE PLAN MAN tASI.If.I Ilk 101�1`1) OWN k0l) (IA) AIICA5041) tAiL IMAINAGI & I lJ w)ol, I(II, I I A/C Mil IN/H 10! li� NAI illjtl) c� I'L t S, I'MA-Lidy mutt FLOOD INFORMAJION: I IM vA1 It) "N"I 1 01'A :; 1:0N, Ill: :IHIVIN Al?l I-W 0y"I'li W, mw III), III it W0410 1 1) Dki-YiNl; MI31ANCL Ill IV11IN NMI A141,10k SIGNAMNIL AND I,AI1 0101.1CAl M 0 -0,i 1,111114W1 NO-) 41ILS' I:i:lll �1411 vi,01-01 ra IIAi 11, FLOOD ZONE i CAlt mm'll'il' (I, ohv'�' 11) 1) All'i mn h, ;x'l;t'FI1iIH 011 'pilllil COMMUNITY NO. it)M,ionor. W)"t SIWWN Ilf"(WN )ilil 1/0i; Wilt M, 'J, I? Ally. IAIW / NI Ill OPI— 0. M I,;" l. PANEL NO. �'b!ll 4M'I' IOR "01 il, IIIAJ� I !,t I I10.,1 I I M111 11114 :1 SUFFIX HLC ').WW 1,11('W�Iii,tAw I; No : ('�' I 1'I(,VjN Aj'j or, 01 1 111.1 PROPI . "I , A) 'I Rt OR Ahlil" 01"ll, i"l' Il. v".i W 0/, 1�0. Ak;LW`; ItUtili IJ4Ibll!AAlI— I<A.� Vi, DATE OF FIRM ADDRESS: DATE OF SURVEY MARSHALL AVENUE SURVEY NO. SANFORD, FLORIDA EGAL DESCRIPIN: 4 SM/? 1, � -Ol 5 . BLOCK 5,IODREAMWO10, ACCORDING 10 IHE FILM 'i, /1' CERTIFIED TO: TKREOF AS RECORDED IN FIAT BOOK 4, PAGE 70. Of ]III F 1 METRO O[VEt0FImCN1 GROUP, INC. PUBUC RECORDS OF SCmiwi-E COUNTY', FLOMDr'. Lill 'kR);sk'kqty I-I"t0j?Wj) kdItitik Ill I'lklH I, trff PROF'ESSIC)NAL SURVEYOR ��- "I (il IIit Aia 410 I ( 11-1' ("' I I IF At 3t)W !?It I)AI; Ul� S!lV(Vfy �„HOWN 11fr(ION A4111 AND Ok f14111 1[I Mi Cli-1 I Rtk x 120294 0045 1 4/17/95 6/21/05 28932 CLOSING SERVICES BY: Hy Hil, HOIINOA W) . ;1kf 1V AJJ282 I HMI !;MMI N', SHORT AVENUE. SUITE 124 LONGWOOD, FLORIDA 32750 70k, I I Ilr:ll"A I G ;3 --- ------ -- FAX: 407-331-9188 ------- ------------- DEVELOPMENT FEE WORK CITY OF SANFORD UTILITY — ADMIN P.O. BOX 1788 SANFORD, FL 32772-1788 Date $ rroj ect Name: !U Zz o� i Phone: Owner/Contact Person: wS Address: -Z v� Type of Development: 1) RESIDENTIAL Type of Units (single family or multi -family): multi -family): Total Number of Units: Type of Utility Connection (individual connections or central water meter & common sewer tap): Water Meter Size (3/4", 1", 2", etc.): REMARKS: 2) NON-RFSLD_E, IAL Type of Units (commercial, Industrial, etc.): Total Number of Buildings: Number of Fixture Units (each building): Type of Utility Connection (individual connections or central water meter & common sewer tap): Water Meter. Size (3/4", 1", 2", etc.) REMARKS: CONNECTION FEE CALCULAT70N.• S w 't l'� z� �7d wgrz G5_'0 / o0 Name Signature - Date vrvrcrn mina City of Sanford "The Friendly City" ; Application for Engineering Permit,, This permit shall authodae work to be done in the City of Sanford based on the approved construction plans and the information provided below: Check One: Right -of -Way Utilization K Driveway THIS APPLICATION IS SUBMITTED BY: PROPERTY OWNE,R(S)/APPLICANT: (� Applicant Name. p � 1r� ,� 11 h3 `A` 1�1 FCCCir,,m���y���...,,, �' �& V4 1164�4 ) Address. I o� 1 L�pl?OY7 \ 11\ Q WJ t V ► \T t5�� e� �s 1 l- L— 3 _s7 Phone. Lj 6-1 — "J \ \'�1 Fax: 4 O"1— � "\�' � �3 Date: 1. PROJECT LOCATI(? v OR ADDRESS: - -v7 J a, 3-1 rn c,, sko_ (I Ayq, v\,u e 2. TITLE OF APPROVED DEVELOPMENT PLANS: - - APPROVAL DATE: SCHEDULE OF WORK: FROM —7__' L7 TO +t0 EMERGENCY REPAIRS 3. 4. PROPOSED ACTIVITY: Driveway Installation Aerial Installation Underground Utilities Bore and Jack Open Cutting of Roadway Sidewalk Installation Other 5. SPECIFIC DESCRIPTION: C.V C Y� _( Y� fA��' 1' (Y�VJ%JA 6. EXCAVATION INFORMATION: Total Length (Feet) Number of Open Roadway Cuts 7. AERIAL INFORMATION: Length (Feet) Number of Poles - (Existing) (New) IT IS UNDERSTOOD AND AGREED THAT THE RIGHTS AND PRIVILEGES HEREIN SET OUT ARE GRANTED ONLY TO THE EXTENT OF THE CITY OF SANFORD'S JURISDICTION AND THE RIGHT, TITLE, OR INTEREST IN THE LAND TO BE ENTERED AND USED BY THE PERMITTEE. THE PERMITTEE SHALL AT ALL TIMES ASSURE ALL RISKS OF AND INDEMNIFY, DEFEND, SAVE HARMLESS THE CITY OF SANFORD FROM AND AGAINST ALL LOSS, COST, DAMAGE, OR EXPENSE ARISING IN ANY MANNER ON ACCOUNT OF THE PERMIT REQUEST BY SAID PERMITTEE OF THE AFORESAID RIGHTS AND PRIVILEGES. IN THE EVENT THAT ANY FUTURE CONSTRUCTION OF ROADWAYS, UTILITIES, STORMWATER FACILITIES, OR ANY GENERAL MAINTENANCE ACTIVITIES BY THE CITY BECOMES IN CONFLICT WITH THE ABOVE PERMITTED ACTIVITY, THE PERMITTEE SHALL REMOVE AND/OR RELOCATE AS NECESSARY AT NO COST TO THE CITY OF SANFORD, INSOFAR AS SUCH FACILITIES ARE IN THE PUBLIC RIGHT-OF-WAY. • CALL THE PBLIC WORKS DEPT. AT (407)330-5681 TO SCHEDULE A PRE -POUR INSPECTION ' 48 HOURS BEFORE YOU DIG CALL SUNSHINE 1-800-432-4770 Applicant Signature Date: Application No:__ - Reviewed: Public Works Utilities Approved: Eng OFFICI RUSE ONLY Fee: - C Clr.. .._.,y. _ * Date: -- --- - - DATE: _ DATE: -. -- DATE: 3..1_ 1 L-5_ En9_Prmpd1 ri� 1 f�US-T 0T KLoc c, �5-(o -i t,W r%- �j'� ii� AJk .kL-C��� (Zo��Dt,. Al <� NORTHO w J i • VARIES i 6, i 6" DRIVE i MAX SLOPE 10:1 MAX. Zb' PLAN CONCRETE CURBIF PAVEMENT AA A� LUSH EXPANSION JOINT SHALL 1q BE REQUIRED BETWEEN CURBING AND APRON. 12" I EDGE OF PAVEMENT SLOPE 1016" X 12" FLUSH CURB `• BOTTOM OF SWALE Sew I SECTION NOTEXSED IN DEVELOPMENTS WITH 1/2 ACRE LOT OR LARGER. J City of Sanford, Florida DRIVEWAY DETAIL FIGURE • Dept. of Engineering N-11 s F t and Planning WITH SWALE N-25 AvO -At <4lj -iV,a r 'r it 1 _ L"�� < r t. } -e - � �� ��' _- /� � � 5 ,� �I' . � �� .0 ma6�Y� yZ,:. g, SaF�. .�3� � _ 'fit - �*' �. ,, ��.+ _ ` �� � � � � p Ei y � � �7)�i�c�et��. �, I` � �I K*4.` n.c+�� 3 � - _. 4 - Z ! �� �,� G I VS �F ;_-- 4i' � e'�� �� -. y ara I c ,'�•� . � yL� :I,�N� - — 4 b 'd:� �. � .w�.. t; - i. _ _. _ _ -. _ .__ . i b i} a...: .— �.. :- FORM 60OA-2001 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs Residential Whole Building Performance Method A ..... .....-- Project Name: 5F08DIST Builder: Address: � _) � %`- Permitting Office: SANFORD City, State: S�NFORD, FL Permit Number: () � q / S' / Owner: SPEC HOME Jurisdiction Number: Climate Zone: Central �01 / c (I t) 1. New construction or existing 2. Single family or multi -family 3. Number of units, if multi -family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (ft') 7. Glass area & type Single Pane a. Clear glass, default U-factor 180.4 ft' b. Default tint 0.0 ft' c. Labeled U or SHGC 0.0 ft' 8. Floor types a. Slab -On -Grade Edge Insulation b. N/A c. N/A 9. Wall types a. Frame, Wood, Adjacent b. Concrete, Int Insul, Exterior c. N/A d. N/A e. N/A 10. Ceiling types a. Under Attic b. N/A c. N/A 11. Ducts a. Sup: Unc. Ret: Unc. AH(Sealed):Garage b. N/A New Single family 1 _ 3 _ No _ 1440 ft' Double Pane 0.0 ft' _ 0.0 ft' 0.0 ft' R-0.0, 139.4(p) ft R=11.0, 416.3 ft' R=4.1, 690.7 ft' R=30.0, 1440.0 ft' _ Sup. R=6.0, 50.0 ft _ 12. Cooling systems a. Central Unit b. N/A c. N/A 13. Heating systems a. Electric Heat Pump b. N/A c. N/A 14. Hot water systems a. Electric Resistance b. N/A c. Conservation credits (HR-Heat recovery, Solar DHP-Dedicated heat pump) 15. HVAC credits (CF-Ceiling fan, CV -Cross ventilation, HF-Whole house fan, PT -Programmable Thermostat, MZ-C-Multizone cooling, MZ-H-Multizone heating) Glass/Floor Area: 0.13 Total as -built points: 21299 PASS Total base points: 21989 I hereby certify that the plans and specifications covered by this calculation are i co pli 4hthe lorida Energy Code. PREPARED BY r, .DATE: os I hereby certify that this b ' ' , as designed, is in compliance with the Florida Energy Code. OWNER/AGENT: DATE: Review of the plans and specifications covered by this calculation indicates compliance with the Florida Energy Code. Before construction is completed this building will be inspected for compliance with Section 553.908 Florida Statutes. BUILDING OFFICIAL: DATE: Cap: 30.0 kBtu/hr _ SEER:10.00 Cap: 30.0 kBtu/hr HSPF: 7.50 Cap: 40.0 gallons _ EF: 0.88 PT, CF, _ we FORM 60OA-2001 SUMMER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS:, SANFORD, FL, PERMIT #: BASE AS -BUILT FGLASSPESditioned X BSPM = Points Overhang Floor Area Type/SC Ornt Len Hgt Area X SPM X SOF = Points .18 1440.0 25.78 6682.2 Single, Clear E 0.0 0.0 15.0 63.97 1.00 959.6 Single, Clear S 15.0 7.7 40.0 48.22 0.50 958.5 Single, Clear N 0.0 0.0 24.0 30.19 1.00 724.6 Single, Clear W 0.0 0.0 30.0 57.68 1.00 1730.4 Single, Clear S 0.0 0.0 30.0 48.22 1.00 1446.7 Single, Clear SE 18.0 6.0 16.0 61.07 0.41 397.4 Single, Clear SE 18.0 7.7 19.4 61.07 0.42 495.4 Single, Clear E 0.0 0.0 6.0 63.97 1.00 383.8 As -Built Total: 180.4 7096.4 WALL TYPES Area X BSPM = Points Type R-Value Area X SPM = Points Adjacent 416.3 0.70 291.4 Frame, Wood, Adjacent 11.0 416.3 0.70 291.4 Exterior 690.7 1.90 1312.3 Concrete, Int Insul, Exterior 4.1 690.7 1.18 815.0 Base Total: 1107.0 1603.7 As -Built Total: 1107.0 1106.4 DOOR TYPES Area X BSPM = Points Type Area X SPM = Points Adjacent 0.0 0.00 0.0 Exterior Insulated 20.0 4.80 96.0 Exterior 20.0 4.80 96.0 Base Total: 20.0 96.0 As -Built Total: 20.0 96.0 CEILING TYPES Area X BSPM = Points Type R-Value Area X SPM X SCM = Points Under Attic 1440.0 2.13 3067.2 Under Attic 30.0 1440.0 2.13 X 1.00 3067.2 Base Total: 1440.0 3067.2 As -Built Total: 1440.0 3067.2 FLOOR TYPES Area X BSPM = Points Type R-Value Area X SPM = Points Slab 139.4(p) -31.8 -4432.9 Slab -On -Grade Edge Insulation 0.0 139.4(p -31.90 -4446.9 Raised 0.0 0.00 0.0 Base Total: -4432.9 As -Built Total: 139.4 -4446.9 INFILTRATION Area X BSPM = Points Area X SPM = Points 1440.0 14.31 20606.4 1440.0 14.31 20606.4 EnergyGauge® DCA Form 60OA-2001 EnergyGauge®/FlaRES'2001 FLRCSB v3.30 FORM 60OA-2001 SUMMER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS:, SANFORD, FL, PERMIT #: ( BASE AS -BUILT Summer Base Points: 27622.6 Summer As -Built Points: _ 27525.6 _ Total Summer X System --- ............. = Cooling Total X Cap - - - X Duct X System X Credit = Cooling Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points (DM x DSM x AHU) 27525.6 1.000 (1.087 x 1.150 x 0.95) 0.341 0.902 10059.8 27622.6 0.4266 11783.8 1 27525.6 1.00 1.188 0.341 0.902 10059.8 EnergyGaugeTm DCA Form 60OA-2001 EnergyGaugeWlaRES'2001 FLRCSB v3.30 FORM 60OA-2001 WINTER CALCULATIONS Residential Whole Building Performance Method A - Details I ADDRESS:, SANFORD, FL, PERMIT #: I BASE AS -BUILT FGLASSPESditioned X BWPM = Points Overhang Floor Area Type/SC Ornt Len Hgt Area X WPM X WOF = Point .18 1440.0 5.86 1518.9 Single, Clear E 0.0 0.0 15.0 12.37 1.00 185.6 Single, Clear S 15.0 7.7 40.0 9.90 2.21 876.8 Single, Clear N 0.0 0.0 24.0 15.07 1.00 361.6 Single, Clear W 0.0 0.0 30.0 13.25 1.00 397A Single, Clear S 0.0 0.0 30.0 9.90 1.00 296.9 Single, Clear SE 18.0 6.0 16.0 10.59 1.94 328.4 Single, Clear SE 18.0 7.7 19.4 10.59 1.88 385.8 Single, Clear E 0.0 0.0 6.0 12.37 1.00 74.2 As -Built Total: 180.4 2906.8 WALL TYPES Area X BWPM = Points Type R-Value Area X WPM = Points Adjacent 416.3 1.80 749.3 Frame, Wood, Adjacent 11.0 416.3 1.80 749.3 Exterior 690.7 2.00 1381.4 Concrete, Int Insul, Exterior 4.1 690.7 3.31 2282.8 Base Total: 1107.0 2130.7 As -Built Total: 1107.0 3032.1 DOOR TYPES Area X BWPM = Points Type Area X WPM = Points Adjacent 0.0 0.00 0.0 Exterior Insulated 20.0 5.10 102.0 Exterior 20.0 5.10 102.0 Base Total: 20.0 102.0 As -Built Total: 20.0 102.0 CEILING TYPES Area X BWPM = Points Type R-Value Area X WPM X WCM = Points Under Attic 1440.0 0.64 921.6 Under Attic 30.0 1440.0 0.64 X 1.00 921.6 Base Total: 1440.0 921.6 As -Built Total: 1440.0 921.6 FLOOR TYPES Area X BWPM = Points Type R-Value Area X WPM = Points Slab 139.4(p) -1.9 -264.9 Slab -On -Grade Edge Insulation 0.0 139.4(p 2.50 348.5 Raised 0.0 0.00 0.0 Base Total: -264.9 As -Built Total: 139.4 348.5 INFILTRATION Area X BWPM = Points Area X WPM = Points 1440.0 -0.28 -403.2 1440.0 -0.28 403.2 EnergyGauge® DCA Form 60OA-2001 EnergyGauge®/FlaRES'2001 FLRCSB v3.30 FORM 60OA-2001 WINTER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS:, SANFORD, FL, PERMIT #: I BASE AS -BUILT Winter Base Points: =005.2 Winter As -Built Points: - ---_ _ ........... .........— 6907.8 - . — Total Winter X System = ---- --- Heating .......... Total X Cap _ X Duct X System X Credit = Heating Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points (DM x DSM x AHU) ............... - —......... ..... ..- 6907.8 1.000 (1.078 x 1.160 x 0.95) 0.455 0.950 3547.7 4005.2 0.6274 2512.9 1 6907.8 1.00 1.188 0.455 0.950 3547.7 EnergyGaugeTM DCA Form 60OA-2001 EnergyGauge®/FIaRES'2001 FLRCSB v3.30 FORM 60OA-2001 WATER HEATING & CODE COMPLIANCE STATUS Residential Whole Building Performance Method A - Details ADDRESS:, SANFORD, FL, PERMIT #: I BASE I AS -BUILT WATER HEATING Number of X Multiplier = Total Tank EF Number of X Tank X Multiplier X Credit = Total Bedrooms Volume Bedrooms Ratio Multiplier 3 2564.00 7692.0 40.0 0.88 3 1.00 2564.00 1.00 7692.0 As -Built Total: 7692.0 CODE COMPLIANCE STATUS BASE AS -BUILT Cooling + Heating + Points Points Hot Water Points = Total Points 11784 2513 7692 21989 1 10060 3548 7692 21299 PASS WE EnergyGaugeT" DCA Form 60OA-2001 EnergyGauge®/FlaRES'2001 FLRCSB v3.30 FORM 60OA-2001 Code Compliance Checklist Residential Whole Building Performance Method A - Details I ADDRESS:, SANFORD, FL, PERMIT #: 6A-21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST COMPONENTS ;.SECTION REQUIREMENTS FOR EACH,PRACTICE _ _;_CHECK Exterior Windows & Doors ! 606 1.ABC.1.1 Maximum:.3 cfm/sq.ft. window area; .5 cfm/sq.ft. door area Exterior & Adjacent Walls 606.1.ABC.1.2.1 foundation & wall sole or sill plate; joints between exterior wall panels at corners; utility penetrations; between wall panels & top/bottom plates; between walls and floor. from, and is sealed to, the foundation to the_top_plate. —. _ Floors 606.1.ABC.1.2.2 Penetrations/openings >1/8" sealed unless backed by truss or joint members. EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed to theperimeter, penetrations and seams. Ceilings 606.1.ABC.1.2.3 Between walls & ceilings; penetrations of ceiling plane of top floor; around shafts, chases soffits, chimneys, cabinets sealed to continuous air barrier; gaps in gyp board & top plate; I I installed that is sealed at the perimeter,_at penetrations and seams. -- .........._— Recessed Lighting Fixtures 606.1.ABC.1.2.4 ! conditioned space, tested. Multi -story Houses t 606 1.ABC.1.2,5 Air barrier on perimeter of floor cavity between floors. Additional Infiltration reqts ! 606.1.ABC.1.3 have combustion air. _ Re-99 f1TI4=D D0RQCRIhTIV11= MFOQI IRFS Imimt ha mat nr aYcandad hV all residences.) COMPONENTS REQUIREMENTS CHECK_ +SECTION Water Heaters 612.1 breaker_(electric or cutoff as _must be provided. External or built-in heat ----required. _. Swimming Pools & Spas 612.1 must have a pump timer. Gas spa & pool heaters must have a minimum thermal efficiency of 78%• — -- —— -- Shower_heads _ 612.1 - -{ Water flow must be restricted _tono more than 2.5 gallons per minute at 80 P51G _ fi...._ Air Distribution Systems ! 610.1 attached, sealed, insulated, and installed in accordance with the criteria of Section 610. I Ducts in unconditioned attics: R-6 min. insulation. ._....... .......- -- _ HVAC Controls 607.1 ; - ............ +_Separate readily accessible manual or automatic thermostat for each system. _ Insulation 604.1, 602.1 Ceilings -Min. R-19. Common walls -Frame R-11 or CBS R-3 both sides. Common ceiling & floors R-11. EnergyGaugeTM DCA Form 60OA-2001 EnergyGauge4D/FlaRES'2001 FLRCSB v3.30 DISPLAY CARD ESTIMATED ENERGY PERFORMANCE SCORE* = 84.1 The higher the score, the more efficient the home. 1. New construction or existing 2. Single family or multi -family 3. Number of units, if multi -family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (ft') 7. Glass area & type Single Pane a. Clear - single pane 180.4 ft' b. Clear - double pane 0.0 ft' c. Tint/other SHGC - single pane 0.0 ft' d. Tint/other SHGC - double pane 8. Floor types a. Slab -On -Grade Edge Insulation b. N/A c. N/A 9. Wall types a. Frame, Wood, Adjacent b. Concrete, Int Insul, Exterior c. N/A d. N/A e. N/A 10. Ceiling types a. Under Attic b. N/A c. N/A 11. Ducts a. Sup: Unc. Ret: Unc. AH(Sealed):Garage b. N/A SPEC HOME, , SANFORD, FL, New _ 12. Cooling systems Single family _ 1 a. Central Unit _ 3 _ b. N/A No v 1440 ft' c. N/A Double Pane _ 0.0 ft' _ 13. Heating systems 0.0 ft' _ a. Electric Heat Pump 0.0 ft' _ b. N/A R=0.0, 139.4(p) ft _ R=11.0, 416.3 ft' _ R=4.1, 690.7 ft' _ R=30.0, 1440.0 ft' _ Sup. R=6.0, 50.0 ft _ c. N/A 14. Hot water systems a. Electric Resistance b. N/A c. Conservation credits (HR-Heat recovery, Solar DHP-Dedicated heat pump) 15. HVAC credits (CF-Ceiling fan, CV -Cross ventilation, HF-Whole house fan, PT -Programmable Thermostat, MZ-C-Multizone cooling, MZ-H-Multizone heating) I certify that this home has complied with the Florida Energy Efficiency Code For Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: Address of New Home: Date: City/FL Zip: Cap: 30.0 kBtu/hr SEER: 10.00 Cap: 30.0 kBtu/hr _ HSPF: 7.50 Cap: 40.0 gallons _ EF: 0.88 _ PT, CF, _ TKE S £9r�D� a �, �1 r��c D WB_K *NOTE: The home's estimated energy performance score is only available through the FLARES computer program. TM your home may qualify for energy efficiency mortgage (EEM) incentives if you obtain a Florida Energy Gauge Rating. Contact the Energy Gauge Hotline at 3211638-1492 or see the Energy Gauge web site at www.fsec.ucf edu for information and a list of certified Raters. For information about Florida's Energy Efficiency Code For Building Construction, contact the Department of Community Affairs at 8501487-1824. EnergyGauge® (Version: FLRCSB v3.30) RIGHT-J LOAD AND EQUIPMENT SUMMARY Entire House CEE BEE AIR SYSTEMS, INC. Job: 5F08DIST 6-8-05 P.O. BOX 2247, APOPKA, Fl- 32704-2247 Phone: 407-886-5960 Fax: 407-886-6326 Email: ceebeeairsystems®cn.rr.com Web: ceebeeair.com Project! . • For: DISTINGUISHED DESIGNS "SPEC HOME" SANFORD/SEMINOLE CTY, FL Notes: 1440 SQ FT Design Information Weather: Orlando AP, FL, US Winter Design Conditions Summer Design Conditions Outside db 38 OF Outside db 93 OF Inside db 70 OF Inside db 75 OF Design TD 32 OF Design TD 18 OF Daily range M Relative humidity 50 % Moisture difference 43 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Building heat loss 24724 Btuh Structure 18240 990 Btuh Btuh Ventilation air Ventilation air loss 50 1760 cfm Btuh Ventilation Design temperature swing 3.0 OF Design heat load 26484 Btuh Use mfg. data Rate/swing multiplier n 0.98 Infiltration Total sens. equip. load 18845 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Fireplaces Average 0 Internal gains 920 Btuh Ventilation 1474 Btuh Heating Coolingg Infiltration 2795 5189 Btuh Btuh Area (ft2) 1422 1422 Total latent equip. load Volume (W) Air changes/hour 11372 1.00 11372 0.50 Total equipment load 24035 Btuh Equiv. AVF (cfm) 190 95 Req. total capacity at 0.70% SHR 2.2 ton Heating Equipment Summary Cooling Equipment Summary Make Make Trade Trade Efficiency 0.0 HSPF Efficiency Sensible cooling 0.0 EER 0 Btuh Heating input Heating output 0 Btuh @ 470F Latent cooling 0 0 Btuh Btuh Heating temp rise Actual heating fan 0 1000 OF cfm Total cooling Actual cooling fan 1000 cfm Heating air flow factor 0.040 cfm/Btuh Cooling air flow factor 0.055 cfm/Btuh Space thermostat Load sensible heat ratio 79 % Bold/italic values have been manually overridden C WPlght50ft Right -Suite ResidentialTM 5.5.06 RSR30434 2005-Jul-11 10:46:21 Page 1 F:\RIGHT J ARCHIVES\2005\5F08DIST.rsr RIGHT-J SHORT FORM Entire House CEE BEE AIR SYSTEMS, INC. Job: 5F08DIST 6-8-05 P.O. BOX 2247. APOPKA, Fl- 32704-2247 Phone: 407-886-5960 Fax: 407.886-6326 Email: ceebeeeirsystems@cfl.rr.com Web: ceebeeair.com Project• . • Make Trade For: DISTINGUISHED DESIGNS "SPEC HOME" SANFORD/SEMINOLE CTY, FL Design Information Htg Clg Infiltration Outside db (OF) 38 93 Method Simplified Inside db (OF) 70 75 Construction quality Average Design TD (OF) 32 18 Fireplaces 0 Daily range - M Inside humidity (%) - 50 Moisture difference (gr/lb) - 43 HEATING EQUIPMENT COOLING EQUIPMENT Make Trade Efficiency 0.0 HSPF Efficiency 0.0 EER Heating input Sensible cooling 0 Btuh Heating output 0 Btuh @ 47°F Latent cooling 0 Btuh Heating temperature rise 0 OF Total cooling 0 Btuh Actual heating fan 1000 cfm Actual cooling fan 1000 cfm Heating air flow factor 0.040 cfm/Btuh Cooling air flow factor 0.055 cfm/Btuh Space thermostat Load sensible heat ratio 79 % ROOM NAME Area (ft2) Htg load (Btuh) Clg load (Btuh) Htg AVF (cfm) Clg AVF (cfm) MAST BED 212 5817 4573 235 251 DINING 89 2492 1277 101 70 FOYER 56 1628 661 66 36 LAUNDRY 71 834 1018 34 56 KITCHEN 105 261 273 11 15 BATH 2 52 130 136 5 7 BED 3 174 4198 4200 170 230 BED 2 163 3651 2685 148 147 FAMILY 364 3324 2112 134 116 MAST BATH 74 1831 1081 74 59 ��1 9'A 12 MAST WIC 63 55 Sold/italic values have been manually overridden vvngrjtsoft Right -Suite Residential- 5.5.06 RSR30434 2005-Jul-11 10:4468; X& F:\RIGHT J ARCHIVES=05\5F08DIST.rsr 9 Entire House d 1422 24724 18240 1000 1000 Ventilation air 1760 990 Equip. @ 0.98 RSM 18845 Latent cooling 5189 T/17A1 C. AAnn 'InA OA nAnnG 4nnn 4AAA v II1LV ITLL LV-TVT �Tvvv �vvv •vv�r Boldlitalic values have been manually overridden wrightsoft Right -Suite Residential"" 5.5.06 RSR30434 F:\RIGHTJ ARCHIVES\2005\5F08DIST.rsr 2005-Jul-11 10:46:21 Page 2 RIGHT-J COMPONENT CONSTRUCTION REPORT Entire House CEE BEE AIR SYSTEMS, INC. Job: 5F08DIST 6-8-05 P.O. BOX 2247, APOPKA, Fl- 32704-2247 Phone: 407-886-5960 Fax: 407-886-6326 Email: ceebeeairsystems@cfl.rr.com Web: ceebeeair.com Project • • • For: DISTINGUISHED DESIGNS "SPEC HOME" SANFORD/SEMINOLE CTY, Fl- Design Information Htg Clg Infiltration Outside db (°F) 38 93 Method Simplified Inside db (°F 70 75 Construction quality Average Design TD (°) 32 18 Fireplaces 0 Daily range - M Inside humidity (%) - 50 Moisture difference (gr/lb) - 43 CONSTRUCTION DESCRIPTIONS AREA R-VAL A/R HTG HTM LOSS CLG HTM GAIN (ft') (ft'-'F/Btuh) (BtuhPF) (BtuhW) (Btuh) (Btuw) (Btuh) WALLS 13C Wd Fr Part, R-1 1, 1 /2" Gypsum,R0.5 Sheath 416 11 37.5 1.4 599 1.2 487 14B Masonry Wall,8" or 12" Block + R-5 691 6.9 99.5 4.6 3183 2.1 1422 IiIG1a9 *KVR 1 C Metal Frame, Single Pane, Clear Glass 121 0.9 140 9A Door,Wood Fr,Single Pane, Clr Glass 19 1.1 18.2 8C SGDoor,Metal Fr,Single Pane,Clear Glass 40 0.9 46.2 DOORS 11A Metal, Fiberglass Core 20 1.7 11.8 CEILINGS 16G Under Unconditioned room, R-30 insulation 1422 30 46.9 FLOORS 22A Slab Floor on Grade, No Edge Insulation 139 1.2 113 37 4472 58 7025 30 581 29 571 37 1477 29 1175 19 377 13 255 1.1 1501 26 3614 1.4 1970 0.0 0 wrightsoft Right -Suite Residential- 5.5.06 RSR30434 2005-Jul-11 10:46:21 )IM F:\RIGHT J ARCHIVES\2005\5F08DIST.rsr Page 1 Sheet Job #: 5F08DIST I CEE BEE AlR SYSTEMS, INC. I Scale: 1 : 86 Performed by JAS DISTINGUISHED DESIGNS "SPEC HOME" SANFORDISEMINOLE CTY FL P.O. BOX 2247 APOPKA, FL 32704-2247 Phone:407-886-5960 Fax:407-886-6326 Page 1 Right -Suite Residential (tm) 5.5.06 RSR30434 2005-Jul-I1 12:55:55 IT J ARCHIVES12005\5FO8DIST for: • DUCT SYSTEM SUMMARY Entire House CEE BEE AIR SYSTEMS, INC. Job: 5FO8DIST 6-8-05 P.O. BOX 2247, APOPKA, FL 32704-2247 Phone: 407-886-5960 Fax: 407-886-6326 Email: ceebeeairsystems@c8.rr.com Web: ceebeeair.com Project• • For: DISTINGUISHED DESIGNS "SPEC HOME" SANFORD/SEMINOLE CTY, FL External Static Pressure: Pressure Losses: Available Static Pressure: Friction Rate: Actual AVF: Total Effective Length (TEL): HEATING COOLING 0.00 in H2O 0.00 in H2O 0.00 in H2O 0.00 in H2O 0.00 in H2O 0.00 in H2O 0.000 in/100ft 0.000 in/100ft 1000 cfm 1000 cfm 359 ft Supply Branch Detail Table Name Htg (Btuh) Clg (Btuh) Htg (cfm) Clg (cfm) Dsn FR Vel (fpm) Dia (in) Rect Sz (in) Duct Matl Trnk MAST BED 5817 4573 235 251 0.000 0 0 9x 0 VIFx st1 DINING 2492 1277 101 70 0.000 0 0 6x 0 VIFx st1 FOYER 1628 661 66 36 0.000 0 0 5x 0 VIFx st1 LAUNDRY 834 1018 34 56 0.000 0 0 5x 0 VIFx st1 KITCHEN 261 273 11 15 0.000 0 0 5x 0 VIFx st1 BATH 2 130 136 5 7 0.000 0 0 4x 0 VIFx st1 BED 3 4198 4200 170 230 0.000 0 0 8x 0 VIFx st1 BED 2 3651 2685 148 147 0.000 0 0 7x 0 VIFx st1 FAMILY 3324 2112 134 116 0.000 0 0 7x 0 VIFx st1 MAST BATH 1831 1081 74 59 0,000 0 0 6x 0 VIFx st1 MAST WIC 557 223 23 12 0.000 0 0 4x 0 VIFx st1 Supply Trunk Detail Table Name Trunk Type Htg (cfm) Clg (cfm) Vel (fpm) Diam (in) Rect Duct Size (in) Duct Material Trunk st1 Peak AVF 1000 1000 0 0 12 x 0 RectFbg Sol0talic values have been manually ovenldden 1 vvnghtsoft Right -Suite Residential TM 5.5.06 RSR30434 /K,6 F:\RIGHT J ARCHIVES\2005\5F08DIST.rsr 2005-Jul-11 10:57:54 Page 1 Return Branch Detail Table Diffus Design Design Design Vel Dia Rect Sz Stud/Joist Duct Name Sz (in) AVF (cfm) (in H2O) FIR (fpm) (in) (in) Opening (in) Matl Trunk rb1 0 x 0 274 0.00 0.000 0 0 14 x 0 VIFx rt1 rb2 0 x 0 71 0.00 0.000 0 0 9 x 0 VIFx rt1 W 0 x 0 142 0.00 0.000 0 0 8 x 0 VIFx rt1 rb4 0 x 0 514 0.00 0.000 0 0 10 x 0 VIFx rt1 Name Trunk Type Htg (cfm) Clg (cfm) Vel (fpm) Diam (in) Rect Duct Sz (in) Duct Material Trunk rt1 Peak AVF 1000 1000 0 0 14 x 0 RectFbg A:. wrjghtsoft Right -Suite Residential- 5.5.06 RSR30434 FARIGHT J ARCHIVES\2005ZF08DIST.rsr 2005-Jul-11 10:57:54 Page 2 r ` 31 DUCT TREE DIAGRAM Entire House CEE BEE AIR SYSTEMS, INC. P.O. BOX 2247, APOPKA, FL 32704-2247 Phone: 407-886-5960 Fax: 407-886-6326 Email: ceebeeairsystems@cfl.rr.com Web: ceebeeair.com For: DISTINGUISHED DESIGNS "SPEC HOME" SANFORD/SEMINOLE CTY, FL Job:5FOSDIST 6-"5 HEATING COOLING External Static Pressure: 0.00 in H2O 0.00 in H2O Pressure Losses: 0.00 in H2O 0.00 in H2O Available Static Pressure: 0.00 in H2O 0.00 in H2O Friction Rate: 0.000 in/100ft 0.000 in/100ft Actual AVF: 1000 cfm 1000 cfm Total Effective Length (TEL): 359 ft Attn: lines indicate branches and trunks, numbers indicate AVF's SUPPLY TRUNKS AND BRANCHES - SCHEMATIC TREE DIAGRAM MAST BED —250. DINING —69. FOYER —36. LAUNDRY —55. KITCHEN —14. BATH 2 —7. BED 3 —230. BED 2 —147. FAMILY —115. MAST BATH —59. MAST WIC —12. RETURN TRUNKS AND BRANCHES rb1 —273, rb2 —70. rb3 —141. rb4 —513, Bold0tallc values have been manually overridden 1000 1000 A:. wrightsoft Right -Suite ResidentialT° 5.5.06 RSR30434 2005-Jul-11 10:57:54 /�, F:\RIGHT J ARCHIVES\2005\5F08DIST.rsr Page 1 Job #: 51F08DIST Performed by JAS for: DISTINGUISHED DESIGNS "SPEC HOME" SANFORD/SEMINOLE CTY FL Sheet 1 CEE BEE AIR SYSTEMS, INC. P.O. BOX 2247 APOPKA, FL 32704-2247 Phone:407-886-5960 Fax:407-886-6326 Scale: 1 : 117 Page 1 Right -Suite Residential (tm) 5.5.06 RSR30434 2005-Jul-11 10:57:45 IT J ARCHIVES\2005\5F08DIST 00: (KU V KMLJU) 1KOO vanywoo M WO I W JC. Top chord 2x4 SP #1 Sot chord 2x4 SP #1 Sub -fascia beam assumptions: 4-3-8 sub -fascia beam on the 0-3-8 cantilever side. 4.3-8 sub -fascia beam on the 0-3.8 cantilever side. 530 in 11 3X4(A1) LEFT RAKE = 1'11"4 LEFT JIG = 44"9 DESC. = CJ3C PLT. TYP: WAVE FBCITPI1 2.63 12 I� 4.15 — a'11 THIS UWG. PREPARED BY THE ALPINE JOB DESIGNER PROGRAM FROM TRUSS MFR'S LAYOUT 120 mph wind, 15.00 ft mean hgt. ASCE 7-98, CLOSED bldg, Located anywhere in roof, CAT II, EXP B, wind TC DL=5.0 psf, wind BC DL=5.0 pef. The following trusses need concentrated loads at the end of their overhangs: 2-11.8 spaNsetback member on the 0-3-8 cant side requires 27 Ibs and the 2-11-8 spantsetback member on the 0-3-8 cant side requires 27 Ibs. Hipjack supports 2-11-8 setback jades with 0-3.8 cantilever one face; 03-8 cantilever opposite face. TCt 6V13 2218� NAILED i - - -NNETN K FXET � n & Rv�213# u"teoa VWC15 �i JUN 06 R.-i0# (�18w NAILED QTY= 2 TOTAL= 2 THIS DRAWING SHOULD BE APPROVED BY A REGISTERED PROFESSIONAL ENGINEER BEFORE USE. SEEPAGE A100 FOR GENERAL NOTES,IMPORTANT SPECIFICATIONS AND WARNINGS. MOUNT OORA,K FLRE& 1013 REV. 7.02.0527.10 TC ILL 20.Opsf TC DL 10.Opsf BC DL 10.Opsf BC ILL O.Opsf TOT.LD. 40.Opsf DU R. FAC. 1.25 SPACING 24.0" RIGHT JIG = 60"13 SEQ = 30715 SCALE=1.3802 REF _ DATE 06-01-2005 O/A LEN. 40203 TYPE hipjack ob:(ROVRML30) /Rod Vermilic /Metro / CJ3 Top chord 2x4 SP #1 Bot chord 2x4 SP #1 Deflection meets L1360 live and L/240 total load. 5w 3X4(A1) tf LEFT RAKE = 1'11"4 LEFT JIG = 4'4"9 DESC. = CJ3 PLT. TYP.-WAVE 1'10"10 2.93 12 v 6"11 Rv"1870 U-leoa W-1019 SEAT PLATE REQUIRED THIS DWG. PREPARED BY THE ALPINE JOB DESIGNER PROGRAM FROM TRUSS 120 mph wind, 15.00 ft mean hgt, ASCE 7-98, CLOSED bklg, Located anywhere in roof, CAT II, EXP B. wind TC DL=5.0 lost, wind BC DL=5.0 psf. Hipjack supports 2-11-8 setback jacks with no webs. TCt 6713 Rv4500 U+IWX NAILED 11 FBCrrPI1995(STD) QTY= 1 TOTAL= 1 THIS DRAWING SHOULD BE APPROVED BY A REGISTERED PROFESSIONAL ENGINEER BEFORE USE. SEE PAGE A100 FOR GENERAL NOTES,IMPORTANT SPECIFICATIONS AND WARNINGS. 10 973 v 1 377 SC aEHMS,P.E. G034 FIECURMt— PLACE JUti 0 6 2005 MOUNT OORAIR 32757 FL. REG.'1 RIGHT JIG = 60"13 SEQ = 30674 REV. 7.02.0527.10 SCALE=1:3802 TC LL TC DL BC DL BC LL TOT.LD. 20.Opsf 10.0psf 10.Opsf 0.0psf 40.Opsf REF DATE 06-01-2005 DRWG O/A LEN. 40203 DUR.FAC. 1.25 SPACING 24.0" TYPE hipjack Top chord 2x4 SP !t1 Bot chord 2x4 SP 91 Webs 2x4 SP #3 Sub4asda team assumptions: 4-" sub-fasda beam on the 0-1-8 cantilever side. 444 sub -fascia beam on the 0.1-8 cantilever side. Deflection meets Lf360 five and L/240 total bad. 526 T 1 THIS UWG. PREPARED BY THE ALPINE JOB DESIGNER PROGRAM FROM TRUSS MFR'S LAYOUT 120 mph wired, 15.00 ft mean hgf, ASCE 7-98, CLOSED bldg. Located anywhere in roof, CAT 11. EXP B, wind TC DL=5.0 psf, wind BC OL=5.0 psf. The following trusaes need concentrated loads at the end of their overhangs: 3-M span/setback member on the 0.1-8 cant side requires 26 lbs and the 3A-0 sparUsetback member on the 0-1-6 cant side requires 26 bs. Hipjack supports 6-11-8 setback jades with 0-1-8 cantilever one face; G-1-8 cantilever opposite face. TC1 V V 12 1- 4'4*5 NAILED 10'4'3 Ir Fri F- 6'11 I W12 Rv=426N 2190 Nk6'„ BC,lat PLACE LEFT RAKE = 1'11"4 LEFT JIG = 1074 DESC.= CJ7C1 PLT. TYP.-WAVE FBC/TPI1 QTY= 1 TOTAL= 1 THIS DRAWING SHOULD BE APPROVED BY A REGISTERED PROFESSIONAL ENGINEER BEFORE USE. SEE PAGE A100 FOR GENERAL NOTES,IMPORTANT SPECIFICATIONS AND WARNINGS. JUN 0 ' 2005 MOUN i DORA, FL SM FL. REG.18243 RIGHT JIG = 11'8"11 SEQ = 30694 REV. 7.02.0527.10 SCALE =0.7142 TIC LL 20.Opsf REF _ TIC DL 10.0pSf DATE 06-01-2005 BC DL 10.OpSf DRWG BC LL O.Opsf TOT.LD. 40.0 DUR.FAC. 1.25 SPACING 24.0" O/A LEN. 91001 TYPE hipjack b:(RDVRML30) /Rod Verm do Watro / CJ7 DWG. PREPARED BY THE ALPINE JOB DESIGNER PROGRAM FROM TRUSS Top chord 2x4 SP #1 Bot chord 2x4 SP #1 Webs 2x4 SP 93 Deflection meets Li360 live and U240 total load 510 120 mph wind, 15.00 R meal hgt, ASCE 7-98, CLOSED bfdg, Located anywhere in roof, CAT II, D(P B, wind TC DL=5.0 psf, wind BC OL=5.0 psf. Hgadk supports 6-11.8 setback jade with no webs. VT12 } 4'4'5 NAILED �-6'11 I W12 }� 1'10'10 .i 71011 RV-4 U•217# VW-Wg BC1 SEAT PLATE REQUIRED LEFT RAKE = 1'11"4 LEFT JIG = 1074 DESC. = CJ7 PLT. TYP: WAVE FBC/TPi1 OTY= 4 TOTAL= 4 THIS DRAWING SHOULD BE APPROVED BY A REGISTERED PROFESSIONAL ENGINEER BEFORE USE. SEEPAGE A100 FOR GENERAL NOTES,IMPORTANT SPECIFICATIONS AND WARNINGS. 10'4'3 F H. EH+ =QS, P.E. 3000001DUk PLACE JUN 0 6 2005 }UNUDG ,Rl -- 3 M. F .. REG. M243 RIGH JIG = I VTI 1 SY0 = 30671 REV. 7.02.0527.10 SCALE =0.7142 TC LL 20.Opsf REF TC DL 10.0psf BC DL 10.Opsf BC LL O.Opsf TOT.LD. 40.Opsf DU R.FAC. 1.25 SPACING 24.0" DATE 06-01-2005 DRWG O/A LEN. 91001 TYPE hipjack Ne" f MC1 Top chord 2x4 SP #1 Bot chord 2x4 SP #1 THIS DWG. PREPARED BY TC1 PROGRAM FROM TRUSS MFR'S LAYOUT 120 mph wind, 8.27 ft mean hgL ASCE 7-98, CLOSED bldg. Located anywhere in roof, CAT It, EXP B. wind TC DL=5.0 psf, wind BC DL--5.0 psf. i'4'4 1'4" TWO R,a2 u=,el# , I 6034 FA�BRIDGE PLACE R6--7# L;zteoa MAILED " 'MATb 2005 MOM DOPA, R 32757 LEFT RAKE = 1',V14 M REG. M24 3 LEFT JIG = 176 RIGHT JIG = ti 4"`i DESC. = BJ1 Cl SEQ = 30707 PLT. TYP.-WAVE FBC/TP11995(STD) QTY= 2 TOTAL= 2 REV. 7.02.0527.10 SCALE =3.3790 TC LL 20.Opsf REF TC DL 10.Opsf DATE 06-01-2005 THIS DRAWING SHOULD BE APPROVED BY A REGISTERED PROFESSIONAL ENGINEER BEFORE USE. SEE PAGE A100 FOR GENERAL NOTES,IMPORTANT SPECIFICATIONS AND WARNINGS. WARNINGS. BC DL 10.Opsf BC ILL TOT.LD. 40.Opsf DRWG O/A LEN. 1 DU R. FAC. 1.25 SPACING 24.0" TYPE jack /Rod Vermdtio /Metro / BJ1 C THIS DWG. PREPARED BY THE ALPINE JOB DESIGNER PROGRAM FROM Top chard 2x4 SP #1 Bot chord 2x4 SP 91 i 1'4' LEFT RAKE = 1'4 14 LEFT JIG = 176 DESC. = BJ1 C PLT. TYP -WAVE FBC/TPI1 120 mph wind, 8.27 It mean hgt, ASCE 7-98, CLOSED bfdg, Located anywhere in root, CAT 11, EXP B, wind TC DL=5.0 pelf, wind BC OL=5.0 psf. TCi QTY= 4 TOTAL= 4 THIS DRAWING SHOULD BE APPROVED BY A REGISTERED PROFESSIONAL ENGINEER BEFORE USE. SEE PAGE A100 FOR GENERAL NOTES,IMPORTANT SPECIFICATIONS AND WARNINGS. 3'4"4 8' r �i�TH H. EH!'�S, P.E. Rr=324#zdo#�eOONERIDac PLACE R.--,ak U-18M "LED RV -150 U•1800 NAILED JUN 0 b 2005 MOUK DORAi R 3W RIGY319 z1 a143 SEQ = 30721 REV. 7.02.0527.10 SCALE=3.3792 TC LL 20.Opsf TC DL 10.Opsf BC DL 10.Opsf BC LL O.Opsf TOT.LD. 40.Opsf DUR.FAC. 1.25 SPACING 24.0" REF DATE 06-01-2005 DRWG O/A LEN. 1 TYPE jack a(KUVKMWU) ntoa Vermnno !Metro / t$J1 Top chard 2x4 SP #1 Bot chord 2x4 SP #1 TCt THIS DWG. PREPARED BY THE. ALPINE JOB DESIGNER PROGRAM FROM TRUSS MFR'S LAYOUT 120 mph wind, 8.27 It mean hgt, ASCE 7-98. CLOSED bldg, Located anywhere in roof, CAT II, EXP B, wind TC DL=5.0 psf, vAnd BC DL=5.0 Pat r4'4 T BC1 R"257# U-18M m*V SEAT PLATE REWIRED ETH No EHi� Si P.E. 6WIMMRINC PLACE JUN 0 6 2.005 MOUNT OOPA9 R 32757 LEFT RAKE = 1'4"14 LEFT JIG = 1'2"6 RI�JF'2'4 p DESC.= BJ1 PLT. TYP.-WAVE FBC/TP11995(STD) QTY= 10 TOTAL= 10 REV. 7,02.0527.10 SEQ = 30690 SCALE=3.3790 TC LL 20.OpSf REF DATE 0"1-2005 TC DL 10.Opsf THIS DRAWING SHOULD BE APPROVED BY A REGISTERED PROFESSIONAL ENGINEER BEFORE USE. SEE PAGE A100 FOR GENERAL NOTES,IMPORTANT SPECIFICATIONS AND WARNINGS. BC DL BC LL TOT.LD. 10.Opsf O.Opsf 40.Opsf DRWG O/A LEN. 1 DUR.FAC. 1.25 SPACING 24.0" TYPE jack THIS DWG. PREPARED BY THE ALPINE lob:(RDVRML30) /Rod Vermillio /Metro / BMC1 Top chord 2x4 SP #1 Bot chord 2x4 SP #1 ,"r LEFT RAKE = 1'4"14 LEFT JIG = V3"6 DESC. = BJ3C4 PLT. TYP: WAVE FBC/TPI1 TCt i - 4",4 %-252# U•1e0# v,-4" 120 mph wind, 8.61 R mean hpt. ASCE 7-98. CLOSED bldg. Locates anywhere in roof, CAT II, EXP B, wind TC OL=5.0 pef, wind BC DL=5.0 pelf. QTY= 2 TOTAL= 2 THIS DRAWING SHOULD BE APPROVED BY A REGISTERED PROFESSIONAL ENGINEER BEFORE USE. SEE PAGE A100 FOR GENERAL NOTES,IMPORTANT SPECIFICATIONS AND WARNINGS. Rw500 U•16010 NAILED f'0"4 W 2• "2 X� - 3 I H. EH! =9-S, P.E. �, ���f9c GLACE ,lUN 0.0 2005 MOM00CR^^A, �+ 32757 RIdf1�MGV4d243 SEQ = 30704 REV. 7.02.0527.10 SCALE=1.9320 TC LL TC DL BC DL BC LL TOT.LD. 20.Opsf 10.Opsf 10.Opsf O.Opsf 40.Opsf REF DATE 06-01-2005 DRWG O/A LEN. 3 DUR.FAC. 1.25 SPACING 24.0" TYPE jack BY THE ALPINE JOB DESIGNER PROGRAM FROM TRUSS MFR'S LAYOUT ob:(RDVRML30) /Rod Vermillio Top chord 2x4 SP #1 Bat chord 2X4 SP #1 M 3X4(At) T 1 1= 1'r RV-248# U-180# w=8" SEAT PLATE REQUIRED TC, 120 mph wind, 8.61 ft mean hgt. ASCE 7-98, CLOSED bldg. Located anywhere in rod, CAT II, EXP B, wind TC DL=5.0 psf, wind BC DL=5.0 psf. LEFT RAKE = 1'4"14 LEFT JIG = 3 3"6 DESC. - BJ3 PLT. TYP.-WAVE FBC/TPI1995(STD) QTY= 8 TOTAL= 8 THIS DRAWING SHOULD BE APPROVED BY A REGISTERED PROFESSIONAL ENGINEER BEFORE USE. SEE PAGE A100 FOR GENERAL NOTES,IMPORTANT SPECIFICATIONS AND WARNINGS. Rv=63# LI.18ON NAILED Y0`4 -31 F . EH C-QS$ P.E. Bc, -�� 034 ' kPLACE JUN 0 7005 MOUNT DURA, ft 32757 L. EG' 18210 RIGHT JIG = 4r4" SEQ = 30687 REV. 7.02.0527.10 SCALE=1.9320 TC, LL 20.Opsf TC DL 10.Opsf BC DL 10.Opsf BC LL O.Opsf TOT.LD. 40.Opsf DU R.FAC. 1.25 SPACING 24.0" REF DATE 06-01-2005 DRWG O/A LEN. 3 TYPE jack Job:(RDVRML30) /Rod V Top chord 2X4 SP 01 Bot chord 2X4 SP 01 a 3X4(A1) T v J: /B=1 DVvG.PREPARED BY 3 DESIGNER PROGRAM FROM TRt LAYOUT 120 mph wind, 8.94 ft mean hgt. ASCE 7-98, CLOSED bldg, not located within 4.50 ft from roof edge, CAT II, EXP B, wind TC DL=5.0 psf, wind BC DL=5.0 psf. Deflection meets U360 live and L1240 total bad. TC1 Rw020M U-11800 NAILED M4 r 1,4-._ �. � EH12Q, R1=3 B,1 U=180k YWI' �, AWN ' _ PL E �4 , JUN 0 � 2005 MOLIDOI' Avf 327 57 LEFT RAKE = 1'4"14 LEFT JIG B 6-Cl 0 564 DESC. = BJSC1 PLT. TYP: WAVE FBC/TPI19WSTD QTY= 2 TOTAL= 2 REV. 7.02.0527.10 SEQ - 30701 SCALE =1.3219 TC LL 20.Opsf REF THIS DRAWING SHOULD BE APPROVED BY A REGISTERED TC DL 10.OpSf DATE 06-01-20050.Ops DRWG PROFESSIONAL ENGINEER BEFORE USE. SEE PAGE A100 BC Dt 1f 0.Ops FOR GENERAL NOTES,IMPORTANT SPECIFICATIONS AND BC LL O/A LEN. 5 WARNINGS. TOT.LD. 40.Opsf OUR. FAC. 1.25 SPACING 24.0" TYPE jack bb:(RDVRML30) /Rod Vemilho /Metro / BJ5 Top chord 2x4 SP #1 Bot chord 2x4 SP #1 T 1 i. PREPARED BY THE ALPINE JOB DESK FROM TRUSS MFR'S LAYOUT 1[u mpn Mara, e.94 It mean hgt, ASC E 7-96, CLOSED blip, not located within 4.50 ft from roof edge, CAT 11, EXP B, wind TC DL=5.0 psf, wind BC DL=5.0 psf. Deflection meets L/360 five and L1240 total bad. r TCt Rv" 122# W 18W NAILED Y$"4 r I-- 4.14 } 47.2 F--- ra• Rv315# U-180M 1N•8' 1c1 �RW4iW� -WaSj P.E. SEAT PLATE REOU RED 6034 FA[ NBRjDGE PLACE AIN 0 v ?005 OWN DORA, R 32767 LEFT RAKE = 1'4"14 LEFT JIG = 5'4"10 q� RI ��r 10243 DESC.= BJS PLT. TYP: WAVE FBC/TPI1995(STD) QTY= 8 TOTAL= 8 REV. 7.02.0527.10 SEQ = 30684 SCALE=1.3219 TC LL 20.OpSf REF _ DATE 06-01-2005NG DL 10.OpSf THIS DRAWINGSHOULD BE APPROVED BY A REGISTERED BC DL 10. 0pS Ops f DRWG PROFESSIONAL ENGINEER BEFORE USE. SEEPAGE A100 FOR GENERAL NOTES,IMPORTANT SPECIFICATIONS AND BC LL O/A LEN. 5 WARNINGS. TOT.LD. 40.Opsf DUR.FAC. 1.255 SPACING 24.0" TYPE jack THIS DWG. PREPARED LPINE JOB DESIGNER PROGRAM FRO! Job:(ROVRML30) /Rod Verm@Io ANetro / EJ3C Top chard 2x4 SP #1 Bot Chord 2x4 SP #1 V4' i 4'14 Rv.2570 U•18M w ra TCt 120 mph wind, 8.61 It mean hpt, ASCE 7-98, CLOSED ft, Located anywhere in roof, CAT II, EXP B. wind TC DL=5.0 psf, wind BC DL=5.0 psf. LEFT RAKE =1 W14 LEFT JIG = 3'3 6 DESC. = EJ3C PLT. TYP.-WAVE FBC/TPI1995(STD) QTY= 2 TOTAL= 2 THIS DRAWING SHOULD BE APPROVED BY A REGISTERED PROFESSIONAL ENGINEER BEFORE USE. SEE PAGE A100 FOR GENERAL NOTESNPORTANT SPECIFICATIONS AND WARNINGS. Rw399 Lf:1800 NAILED 9'0'4 8' 27'2X -3' kffiE H.EHr-- S P.E. BC,111OMPIGEPLACE J► N o n zoo MOUt+ DDRA5 R 32757 FL AEG. 18243 RIGHT JIG = 44 SEQ = 30718 REV. 7.02,0527.10 SCALE=1.9321 TC LL TC DL BC DL BC LL TOT.LD. 20.Opsf 10.OpSf 10.Opsf O.OPSf 40.OpSf REF DATE 06-01-2005 DRWG O/A LEN. 3 DUR.FAC. 1.25 SPACING 24.0" TYPE ejack THIS DWG. DESIGNER PROGRAM FROM TRUSS MFR'S LAYOUT b:(RDVRML30) /Rod VemeBio /Metro / EJ3 Top chard 2x4 SP #1 Bot Chard 2x4 SP #1 M 3X4(A1) T v 1 i lr Rw248# U-18(W W-S' SEAT PLATE REQUIRED TC1 120 mph wind, 8.61 R mean hpt, ASCE 7-98, CLOSED bldp, Located anywhere in roof, CAT II, EXP B, wind TC DL=5.0 psf, wind BC DL=5.0 psf. RAKE = 1'4" 14 JIG = 376 rYP.-WAVE FBC/TPI1995(STD) QTY= 2 TOTAL= 2 THIS DRAWING SHOULD BE APPROVED BY A REGISTERED PROFESSIONAL ENGINEER BEFORE USE. SEEPAGE A100 FOR GENERAL NOTES,IMPORTANT SPECIFICATIONS AND WARNINGS. Rvw53# U•180N NAILED ro-4 r _3' --r Bc, i%24�, He G �i�.�,i�:. WNFAL J OI N 0 n 2005 RIGHT J �W4 SEQ = 30681 REV. 7.02.0527.10 SCALE=1.9321 TC LL 20.Opsf TC DL 10.0PSf BC DL 10.Opsf BC LL O.Opsf TOT.LD. 40.Opsf DUR.FAC. 1.25 SPACING 24.0" REF DATE 06-01-2005 DRWG O/A LEN. 3 TYPE ejack bb:(RDVRML30) /Rod Top chord 2x4 SP #1 Bot chord 2x4 SP 91 LEFT RAKE = 1'4"14 LEFT JIG = 75"14 DESC. = EJ7C1 PLT. TYP.-WAVE Rv=397#' u=tao# vo.4• FBC/TPI1 THIS DWG. ALPINE JOB DESIGNER PROGRAM FROM TRUSS MFR'S LAYOUT 120 mph wind, 9.27 It mean hgt, ASCE 7-98, CLOSED bldg. not located within 4.50 R from roof edge, CAT 11, EXP B. wind TC DL=5.0 psf, wind BC DL=5.0 psf. DefWtlon meets U360 Ive and 11240 trial load TCt NAILED QTY= 4 TOTAL= 4 THIS DRAWING SHOULD BE APPROVED BY A REGISTERED PROFESSIONAL ENGINEER BEFORE USE. SEE PAGE A100 FOR GENERAL NOTES,IMPORTANT SPECIFICATIONS AND WARNINGS. IDS sc1 i Duc PLACE rUN 0 6 20e5 mount RI IWOIJ0za3 SEQ = 30697 REV. 7.02.0527.10 SCALE=1.0047 TC LL 20.Opsf TC DL 10.Opsf BC DL 10.Opsf BC LL O.Opsf TOT.LD. 40.Opsf DUR.FAC. 1.25 SPACING 24.0" REF DATE 06-01-2005 DRWG O/A LEN. 7 TYPE ejack Top chord 2x4 SP #1 Bot chord 2x4 SP #1 THIS LED BY THE ALPINE JOB DESIGNER PROGRAM FROM TRUSS MFR 120 mph wind, 9.27 ft mean hgt, ASCE 7-98, CLOSED burp, not bcated within 4.50 ft from roof edge. CAT 11, EXP B, wind TC DL=5.0 pat, wind BC DL=5.0 psf. l7eHectbn meets U360 live and U240 total load. TCt NAILED 1174'4 r I•" 4.14 I B7'2 G� �� Rr: U -180N W=E' aC1 8015W14"AiN7 �i~-_ �� r .ua SEAT PLATE REQUIRED 6034 FALL@ 11iC3c PLACE UN 0 6 ZDD-D MOUNITOORAIR 32757 LEFT RAKE = 1W14 G � 1 43 LEFT JIG = 75"14 RIG9—f DESC. = EJ7 SEQ = 30678 PLT. TYP.-WAVE FBC/TPI1995(STD) QTY= 18 TOTAL=18 REV. 7.02.0527.10 SCALE=1.0047 TC LL 20.Opsf REF THIS DRAWING SHOULD BE APPROVED BY A REGISTERED PROFESSIONAL ENGINEER BEFORE USE. SEE PAGE A100 FOR GENERAL NOTES,IMPORTANT SPECIFICATIONS AND TC DL 10.Opsf BC DL 1 O.OpSf BC LL O.OpSf DATE 06-01-2005 DRWG O/A LEN. 7 WARNINGS. TOT.LD. 40.OpSf DU R. FAC. 1.25 SPACING 24.(r ITYPE ejack /Rod Vermdtlo Metro / E2 Top chord 2x4 SP #1 Bot chard 2x6 SP #1 Webs 2x4 SP #3 THIS GIRDER DESIGNED TO SUPPORT 21-2-8 SPAN FRAMING TO THE BOTTOM CHORD FROM ONE SIDE. OPPOSITE SIDE SUPPORTS 3-M JACKS. JACKS HAVE NO WEBS. TCt 31 3. 1701# ll=765# „4-V eC, SEAT PLATE REQUIRED THIS DWG. PREPARED BY THE ALPINE JOB DESIGNER PROGRAM FROM TRUSS MFR'S LAYOUT 120 mph wind, 15.00 ft mead hpt, ASCE 7-98, CLOSED bid0, Located anywhere in roof, CAT II, EXP B, wind TC DL=5.0 psf, wind BC DL=5.0 psf. H = recommended connection based on manufacturer tested capacitles and calculations. Conditions may exist that require different connections than indicated. Refer to manufacturer publication for additional information. Deflection meets U360 We and 1-1240 total load LEFT JIG = 33"6 DESC. = E2 PLT. TYP.•WAVE FBC/TPI19WSTD) QTY= 1 TOTAL= 1 THIS DRAWING SHOULD BE APPROVED BY A REGISTERED PROFESSIONAL ENGINEER BEFORE USE. SEE PAGE A100 FOR GENERAL NOTES,IMPORTANT SPECIFICATIONS AND WARNINGS. — TC2 _4. 5XS(R) .E. tea ;L�a~ I: ,�,tNEPC PLACE JUN 0 6 2005 Rw1581# U-6M H-Simpson HUS26 wp®) 10d Comman. 0.148 SC3.0- nexe UTDO13A FL 3275T Oder 8 ) 1 n 33, 30 3P ScUd�' FL. AEG.18243 RIGHT JIG = 4'2"9 SEQ = 30588 REV. 7.02.0527.10 SCALE=1.1960 TC LL 20.Opsf TC OL 10.0pSf BC DL 10.0psf BC LL 0.0psf TOT.LD. 40.Opsf DUR.FAC. 1.25 SPACING 24.0" REF DATE 06-01-2005 DRWG O/A LEN. 7 TYPE hipm b:(RDVRML30) /Rod Venmiflo Top chord 2x4 SP 01 Bat Chord 2x6 SP #1 Webs 2x4 SP 03 / Ef SPECIAL LOADS --{LUMBER DUR.FAC.=1.25 / PLATE DUR.FAC.=1.25) TC - From 60 PLF at 0.00 to 60 PLF at 7.00 BC - From 20 PLF at 0.00 to 20 PLF at 7.00 BC - 2345 LB Conc. Load at 1.46 BC - 968 LB Conc. Load at 3.40, 5.40 H = recommended confection based on manufacturer tested capacities and calculations. Conditions may exist that require different connections than indicated. Refer to manufacturer publication for additional information. THIS UAG. PREPARED BY 2 Complete Trusses JOB DESIGNER PROGRAM FROM TRUSS MFR'S I AYrx rT NAILING SCHEDULE: (10d box nails) TOP CHORD: i ROW 12` o.c. BOT CHORD: 2 ROWS 6" o.c. (EACH ROM WEBS 1 ROW 4 o.c. USE EQUAL SPACING BETWEEN ROWS AND STAGGER NAILS IN EACH ROW TO AVOID SPLITTING. 120 mph wind, 15.00 ft mean hgt, ASCE 7-98. CLOSED Bldg, not located within 4.50It from root edge, CAT 11. EXP B, wind TC OL=5.0 Pat, wind BC DL=5.0 par. Right end vertical not exposed to wind pressure. TCt 4'3'10 2'e'10 i-- 1'S8 1'11'4 Z iT4 zU>. rb" 3X4 Rv= 1M U=1083M LMB' BC1 SEAT PLATE REOURED LEFT JIG = 7614 DESC. = E1 PLT. TYP.-WAVE FBC/TPI19WSTD) QTY= 1 PLIES= 2 TOTAL= 2 THIS DRAWING SHOULD BE APPROVED BY A REGISTERED PROFESSIONAL ENGINEER BEFORE USE. SEE PAGE A100 FOR GENERAL NOTES,IMPORTANT SPECIFICATIONS AND WARNINGS. Rw18600 L0588M H-Sim son HHUS26-2 w/(6)10d Common, 0.148'14.0" mills In Truss 10d Common, 0A48W.0' nullsIn Glyder Gbdx Is (2) f.Wx 5.50 SP So#dSawn `IHE H H.atcaq D c SN"ArFALCONSIMEFUCE JUN 0 6 20r 5 �ItQUN3L#wBA,;.L 32757 FL. REG.18243 RIGHT JIG = TO"1 SEQ = 30637 REV. 7.02.0527.10 SCALE=1.0251 TC LL 20.Opsf TC DL 10.Opsf BC DL 10.Opsf BC LL O.Opsf TOT.LD. 40.Opsf DUR.FAC. 1.25 SPACING 24.0" DATE 06-01-2005 DRWG O/A LEN. 7 TYPE mono J 0.tMVVKM{LJUI/KOO VOrMOO/NJW0I 72 Top chord 2x4 SP #1 Bat chord 2x4 SP #1 Webs 2X4 SP #3 Left side jades have 3-M setback with 0-4-0 cant and 1-4-0 overhang. End jades have 3-0-0 setback with 0.0-0 cart and I -" overhang. Right side jacks have 3.40 setback with 0.4.0 cart and 1-4-0 overhang. THIS DA G. PREPARED BY THE ALPINE JOB DESIGNER PROGRAM FROM TRUSS MFR'S LAYOUT 120 mph wind, 15.00 ft mean hgt, ASCE 7-96, CLOSED bldg, Laded anywhere in roof, CAT II, EXP B, wild TC DL=5.0 psf, wind BC DL=5.0 psf. #1 hip supports 3-0-0jacks with no webs. Deflection meets U360 live and L/240 total load. TCf TC2 •�• TC3 3' 1• 3' 4X4 4X4 12 4 p w1 3X4(Al) � hk LLU 1 fa• ri 3X4 3X4 28'14 8'8 I 78.14 4'14 - jN u U D 1'4" r PlIf I 3' ion '' 10 6034 FALCO1+ RJC�E PLAC9 Ib- U-230 V03.8 BC1 "460 U=23aN w=78 JUN 0 fit 2005 LEFT RAKE = 1'414 LEFT JIG = 33*6 DESC. = D2 PLT. TYP.-WAVE FBC/TPI1 QTY=1 TOTAL= 1 THIS DRAWING SHOULD BE APPROVED BY A REGISTERED PROFESSIONAL ENGINEER BEFORE USE. SEE PAGE A100 FOR GENERAL NOTES,IMPORTANT SPECIFICATIONS AND WARNINGS. MOUK DiiOPAg R 32757 RIG1iTJ SEQ = 30712 REV. 7.02.0527.10 SCALE =0.8661 TC LL 20.Opsf REF TC DL 10.Opsf DATE 06-01-2005 BC DL 10.0psf BC ILL O.Opsf TOT.LD. 40.Opsf DRVVG O/A LEN. 7 DU R. FAC. 1.25 SPACING 24.0" TYPE hips 1ob:(RDVRML30) /Rod Vermi lio Top chord 2x4 SP # 1 Bot chord 2X4 SP 91 V*bs 2x4 SP #3 3X4(A1) LEFT RAKE = 11"1 LEFT JIG = 39'11 DESC. = D1 PLT. TYP: WAVE Iu THIS DWG, PREPARED BY DESIGNER PROGRAM FROM TRUSS MFFrS LAYOUT 120 mph wind, 8.77 ft mean hgt, ASCE 7-98, CLOSED bldg, not located within 4.50 ft from roof edge, CAT 11, EXP B, wind TC DL=5.0 psf, wind BC OL=5.0 psf. Deflection meets U360 live and U240 total load. TC1 TC2 I 3V 4- 3r 3r Te• I..- t(rs f` 4'h4 31'2 .+. 3'1Z 4'14..I KENMEM H. EH r 8.r P.E. BC, FQ34 F L IONBRIDGE PLACE Rw Lh180M W+3'8 Rv=336111 U=180# W�3'8 .SUN 0 6 2005 FBC/TPI1 QTY= 1 TOTAL= 1 THIS DRAWING SHOULD BE APPROVED BY A REGISTERED PROFESSIONAL ENGINEER BEFORE USE. SEE PAGE A100 FOR GENERAL NOTES,IMPORTANT SPECIFICATIONS AND WARNINGS. MOUNT DORA, R 32757 RIG&AREG"1lg43 RIGHT JIG = 3'9"11 SEQ = 30709 REV. 7.02.0527.10 SCALE=0.9568 TC LL TC DL BC DL BC LL TOT.LD. 20.Opsf 10.OpSf 10.0p8f 0.0psf 40.OpSf REF DATE 06-01-2005 DRWG O/A LEN. 7 DUR.FAC. 1.25 SPACING 24.0" TYPE Coma /Metro / C5 Tap chord 2x4 SP 91 Bot chord 2x4 SP #1 Webs 2x4 SP #3 Left side jades have 7." setback with 0-" cant and 1-4-0 overhang. End jacks have 7-0A setbackwith 0-(10 cant and 1-4-0 overhang. Right side jacks have 7-0-0 setback with 0-00 card and 14-0 overhang. 1— P4• TC1 I r r` 310'14 31.2 ♦ 3'g• r 4"A Rv=1754k U=61 Nk8' Sc1 SEAT PLATE REQUIRED LEFT RAKE = 1'4"14 LEFT JIG = 75"14 DESC. = C5 PLT. TYP -WAVE FBC/TPI1 THIS DWG THE ALPINE JOB DESIGNER PROGRAM FROM TRUSS MFR'S LAYOUT 120 mph wind, 15.00 ft mean hgt, ASCE 7-98, CLOSED bidg, Located anywhere in roof, CAT II, EXP B. wind TC DL=5.0 psf, wind BC OL=5.0 W #1 hip supports 7-0.0 jacks with no webs. Deflection meets LJ360 live and L/240 total load. TC2 TO r4• "+` r ♦ 3'6• 3'1.2 310'14 .{ 21'4•` '� . p� yy 'ri !i EHU.='��, P.E. ra• r ' � Fi�1�COMBRR1DUE PLACE 1 TOTAL= 1 THIS DRAWING SHOULD BE APPROVED BY A REGISTERED PROFESSIONAL ENGINEER BEFORE USE. SEE PAGE A100 FOR GENERAL NOTES,IMPORTANT SPECIFICATIONS AND WARNINGS. U•617A E B' JUN 0 too 2G05 Rv=1754# VVF+ SEAT PLATE REQUIRED REV. 7.02.0527.10 MOUNT ��DORA,,ggFL 33q2�Ti RIGI1T'JI1$�� SEQ = 30641 SCALE=0.3488 pSf REF psf DATE 06-01-2005 PSf DRWG psf (�f O/A LEN. 210400 TC LL 20.0 TC DL 10.0 BC DL 10.0 BC LL O.O TOT.LD. 40.0 DUR.FAC. 1.25 SPACING 24.0" TYPE 0:(KUVKML9U) lKOO Top chord 2x4 SP #1 Bot chord 2x4 SP #1 Web$ 2x4 SP #3 G4 THIS DWG. PREPARED BY THE ALPINE JOB DESIGNER PROGRAM FROM TRUSS MFR'S LAYOUT 120 mph wind, 9.61 ft mean hgt, ASCE 7-98, CLOSED burp, not located within 4.50 It from rod edge, CAT II, EXP B, wind TC DL=5.0 psf, wind BC DL=5.0 p14. Deflection meets V360 Rvve and LI240 total bad TCt TC2 TO I9 3'4' .I. 9 4'1a14 .}. VI'2 3'4' I 4'1'2 + rliru----.I VW14 i— 1'4' + Rw# 839# U=z5 n*e• SC1 SEAT PLATE REQUIRED LEFT RAKE = 1'4"14 LEFT JIG = 97"2 DESC. = C4 PLT. TYP: WAVE FBC/TPI1 374 ♦ 87'2 inNETH H. Eye LL'79 S, P.E.era• S a �+ �i ISRINE r LACE Rr-O3 L--51N OL-* SEAT PLATE REQUIRM It+N 0 6 20 05 QTY= 1 TOTAL= 1 THIS DRAWING SHOULD BE APPROVED BY A REGISTERED PROFESSIONAL ENGINEER BEFORE USE. SEEPAGE A100 FOR GENERAL NOTES,IMPORTANT SPECIFICATIONS AND WARNINGS. MOUNT DORA, F1 32757 FL. REG.18243 RIGHT RAKE=1'4"14 RIGHT JIG = 97"2 SEQ = 30645 REV. 7.02.0527.10 SCALE=0.3488 TC LL 20.0pSf REF TC DL 10.Opsf DATE 06-01-2005 BC DL 10.Opsf DRWG BC LL 0.Opsf TOT.LD. 40.Opsf DUR.FAC. 1.25 SPACING 24.0" O/A LEN. 210400 TYPE h IOO:kKNV KMIJUJ MOO VOM1440 IMSUO / UJ THIS MG. PREPARED BY THE ALPINE JOB DESIGNER PROGRAM FROM TRUSS MFR'S LAYOUT Top chord 2x4 SP 01 120 mph wind, 9.88 R mean hgt, ASCE 7-98, CLOSED b Idg, not located within 4.50 R from roof edge, CAT 11, EXP B. wind TC Bot chord 2x4 SP #1 DL=5.0 psf, wind BC DL=5.0 psf. VVebs 2x4 SP 93 Deflection meets L/360 five and L/240 total bad. SPECIAL LOADS /PLATE C.=1.25) PLF TC From 60LUMBER at� 1.33 to 60 PLF at 22.67 BC - From 4 PLF at -1.33 to 4 PLF at 0.00 BC - From 20 PLF at 0.00 to 20 PLF at 0, 81 BC - From 50 PLF at 0.81 to 50 PLF at 20.52 BC - From 20 PLF at 20.52 to 20 PLF at 21.33 BC - From 4 PLF at 21.33 to 4 PLF at 22.67 TCt TC2 i . 109' ♦ 10'8' 5'8'14 F. 4'11.2 I' 4'11'2 ♦ W14 3X4(A1) 11 T 1 21'4' 6'S'13 f"' p4• I 21'4•. Rv+234N LM42 vwa• BC, SEAT PLATE REO ARED LEFT RAKE = 1'4"14 LEFT JIG = 11'4"4 DESC. = C3 PLT.TYP-WAVE FBC/TPI1 QTY= 2 TOTAL= 2 THIS DRAWING SHOULD BE APPROVED BY A REGISTERED PROFESSIONAL ENGINEER BEFORE USE. SEEPAGE A100 FOR GENERAL NOTES,IMPORTANT SPECIFICATIONS AND WARNINGS. W2 Rv=,234p ,;W4 1ACCONBRIDGc PLACE SEAT PLATE RECURED JUN 0 6 2005 MOUNT DORA, FL 32757 RICMFAI RIGHT JIG = 11'4"4 SEQ = 30650 REV. 7.02.0527.10 SCALE=0.3488 TC LL 20.OpSf REF TC DL 10.0pSf DATE 08-01-2005 BC DL 10.Opsf DRWG BC LL O.Opsf TOT. LD. 40.Opsf DUR.FAC. 1.25 SPACING 24.T O/A LEN. 210400 TYPE comn bb: (RDVRML30) /Rod Vermillic !Metro / C2 Top chord 2x4 SP 91 Bot chord 2x4 SP #1 Webs 2x4 SP 93 SPECIAL LOADS —{LUMBER DUR.FAC.=1.25 / PLATE DUR.FAC.=1.25) TC - From 60 PLF at 0.00 to 60 PLF at 22.54 BC - From 20 PLF at 0.00 to 20 PLF at 0.69 BC - From 50 PLF at 0.69 to 50 PLF at 20.40 BC - From 20 PLF at 20.40 to 20 PLF at 21.21 BC - From 4 PLF at 21.21 to 4 PLF at 22.54 PROGRAM FROM TRUSS MFR'S LAYOUT 120 mph wind, 9.88It mean hgt, ASCE 7-98, CLOSED bldg, not located within 4.50 it from roof edge, CAT 11. EfP B, wind TC DL=5.0 psf, wind BC DL=5.0 psf. Deflection meets Lf360 live and L/240 total load. THIS DVVG. PREPARED BY THE ALPINE TC1 F= ta6'8 i 57"8 4'1 M 4'11"2 4X4 ir\ 0 b M 3X4(A1) 1 12 4 C�;,- Fu 1 6110"15 3X4 3X4 RV-1142# U= VO4r$ BCt SEAT PLATE REQUIRED LEFT JIG = 11713 DESC. = C2 PLT, TYP.-WAVE F13C/TPI1 law Me TC2 5'8"14 2178 c P + BC2 Rw-1231# U•425# AW SEAT PLATE REOt.MD J U N G b LOOS MUNI DOPAY �� 32751 R. REGA8243 RIGHT RAKE = 1'4"14 RIGHT JIG = 11'4"4 SEQ = 30655 QTY= 1 TOTAL= 1 REV. 7.02.0527.10 SCALE=0.3714 THIS DRAWING SHOULD BE APPROVED BY A REGISTERED PROFESSIONAL ENGINEER BEFORE USE. SEE PAGE A100 FOR GENERAL NOTES,IMPORTANT SPECIFICATIONS AND WARNINGS. TC LL 20.Opsf TC DL 10.Opsf BC DL 10.Opsf BC LL O.Opsf TOT. LD. 40.Opsf DU R.FAC. 1.25 SPACING 24.0" REF DATE 08-01-2005 DRWG O/A LEN. 210208 TYPE Coma yermillio /Metro / Cl THIS Top Chord 2x4 SP #1 Bot chord 2x4 SP 91 Webs 2x4 SP 93 SPECIAL LOADS --(LUMBER DUR.FAC.=1.25 / PLATE DUR.FAC.=1.25) TC - From 60 PLF at 0.00 to 60 PLF at 22.54 BC - From 20 PLF at 0.00 to 20 PLF at 0.69 BC - From 50 PLF at 0.69 to 50 PLF at 20.40 BC - From 20 PLF at 20.40 to 20 PLF at 21.21 BC - From 4 PLF at 21.21 to 4 PLF at 22.54 I 5T6 TC, 106'8 12 4 p 3X4 3X4 I scl RV-11390 3113# H•Slnpson HUS26 w/(6)10d Common, 0.148W.0' nalls In Truss w104)10d Cannon, 0.1481)0.0' nalls In Order Orderis (1) 1.50x 5.50 SP SoldSawn LEFT JIG = 11713 DESC. = C1 PLT. TYP.-WAVE FBC/TPI1 REPARED BY THE ALPINE JOB DESIGNER PROGRAM FROM TRUSS MFR'S LAY( i Zu mpn wlno, a. cuts n mean rpt, ASCE 7-98, CLOSED bide, not located within 4.50It from roof edge. CAT I I, EXP B, wind TC DL=5.0 pelf, wind BC OL=5.0 psf. H = recommended connection based on manufacturer tested capacities and calculations. Conditions may exist that require different connections than indicated. Refer to manufacturer publication for additional information. Deflection meets U360 live and 1-240 total load. TC2 1 10'8' 1'2 ♦ 4Y1'2 ♦ 66'14 4X4 3X4 vW � 3X4(Al) 'fir s 8' 5X6 21 88,13 ♦ ell"lt 91 uMUM, PS 2176 RIDGE PLACE Scz Rv=1234# u=420 Hae� A' (� V SEAT PLATE REQU RED J U N S 005 6s QUKT J)00 A J FL 32757 1 F, R.1$243 RIGHT RAKE = 1'4"14 RIGHT JIG = 11'4"4 SEQ = 30660 QTY= 3 TOTAL= 3 REV. 7.02.0527.10 SCALE=0.3714 TC LL 20.Opsf IREF THIS DRAWING SHOULD BE APPROVED BY A REGISTERED PROFESSIONAL ENGINEER BEFORE USE. SEE PAGE A100 FOR GENERAL NOTES,IMPORTANT SPECIFICATIONS AND WARNINGS. TC DL 10.0pSf BC DL 10.0pSf BC LL O.OPSf TOT. LD. 40.Opsf DUR.FAC. 1.25 SPACING 24.0" DATE 06-01-2005 DRWG O/A LEN. 210208 TYPE cornn /Rod Vermilko /Metro 163 THIS THE ALPINE JOB DESIGNER PROGRAM FROM TRUSS MFR'S LAYOUT Tap chord 2x4 SP #1 Bot chord 2x6 SP #1 :BC2 2x4 SP #1: Webs 2x4 SP 93 SPECIAL LOADS ---(LUMBER DUR.FAC.=1.25 / PLATE DUR.FAC.=1.25) TC - From 60 PLF at 0.00 to 60 PLF at 25.67 BC - From 20 PLF at 0.00 t o 20 PLF at 24.33 BC - From 4 PLF at 24.33 to 4 PLF at 25.67 BC - 1561 LB Conc. Load at 3.06 Deflection meets U360 Irve and U240 total load 2 Complete Trusses Required NAILING SCHEDULE: (10d box nails) TOP CHORD: 1 ROW 124 o.c. BOT CHORD: 1 ROW 12" o.c. WEBS :1ROW o.c. USE EQUAL SPACING BETWEEN ROWS AND STAGGER NAILS IN EACH ROW TO AVOID SPLITTING. 120 m h wind, 15.00 ft mean tgt, ASCE 7-98, CLOSED bldg. not located within 4.50 ft from roof edge, CAT 11. D(P B, wind TC DL=5.8 psf, wind BC 0L=5.0 Dsf H = recommended connection based on manufacturer tested capacities and calculations. Conditions may exist that require different connections than indicated. Refer to manufacturer publication for additional information. TC1 A_ TC2 - A TC3 }- 7 I 3' -Tr + 10'6" I Cr4 h z5"12 38" + C11z + TC4 ST14 —{ - . . �..}��" ►��I+—3'b'10-- —7i9--28'8—+{�-311' 24'4' 9 �}+ Urn -- �j�liNsRID 4�.G rtE IPd.jFCi/i.0 I I�3712 ,SS,. sc1 Rv--23450 916k H=Smpsm HGUS262 w1(4) 16d, 0.162*4.5" nel s In Truss w/(20)16d, 0.1625Q.5" nsis In Girder Gkdw is (2) 1.50x 5.50 SP SosdSewn LEFT JIG = TS"14 DESC. = B3 PLT. TYP: WAVE FBC/TPI1 21'3"4 QTY= 1 PLIES= 2 TOTAL= 2 THIS DRAWING SHOULD BE APPROVED BY A REGISTERED PROFESSIONAL ENGINEER BEFORE USE. SEEPAGE A100 FOR GENERAL NOTES,IMPORTANT SPECIFICATIONS AND WARNINGS. JUN 6 6 j00 a BC2 �T�TE R ��1 �iT DORA, F�. 3 757 F!" REG. i6243 REV. 7.02.0527.10 TC ILL 20.Opsf TC DL 10.Opsf BC DL 10.Opsf BC LL O.Opsf TOT.LD. 40.Opsf DUR.FAC. 1.25 SPACING 24.0" RIGHT RAKE = 1'4"14 RIGHT JIG = 11'4 3 SEQ = 30614 SCALE=0.3262 REF DATE 06-01-2005 DRWG O/A LEN. 240400 TYPE spec /Rod VermHHo /Metro / B2 THIS DING. PREPARED BY THE DESIGNER PROGRAM FROM TRUSS MFR'S Top chard 2x4 SP #1 Bot chord 2x4 SP #1 VAebs 2x4 SP #3 Deflection meets U360 live and LJ240 total load. 120 mph wind, 9.88 It mean hgt, ASCE 7-96, CLOSED Bldg, not located within 4.50 fl from roof edge, CAT II, EXP B. wind TC DL=5.0 psf, wind BC 01-=5.0 psf. H = recommended connection based on manufactiuer tested capacities and calculations. Conditions may exist that require different connections than indicated. Refer to manufacturer publication for additional information. TC1 TC2 —+ TC3 i 5 3' 1'8' t F 4'1(f14 I 4'1'2 I 3' --— 1'8' - I 4'11'2 FAT 8'8'14 4'8'4 -4 BC, RV-96810 249# H-Sh pson HUS26 w/(4)16d, 0.162-W,5' nds In Tnas w/(14)16d, 0.162' ia.5' nds In Girder Girder Is (2) 1.50x 5.50 SP SoIldSewn LEFT JIG = 9'T'2 DESC. = B2 PLT. TYP.-WAVE F BC/TPI1 24'4' QTY= 1 TOTAL= 1 THIS DRAWING SHOULD BE APPROVED BY A REGISTERED PROFESSIONAL ENGINEER BEFORE USE. SEE PAGE A100 FOR GENERAL NOTES,IMPORTANT SPECIFICATIONS AND WARNINGS. TC4 5V14 w S ,0'3-2 I�l� PLACE - BC2 Rv=,o64# U• e 1n fS' i u N 0 G 2105 SEAT PLATE REQUIRED MUMMA, FL 32757 erl'"REG. 15243 REV. 7.02.0527.10 TC LL 20.Opsf TC DL 10.0psf BC DL 10.Opsf BC LL O.Opsf TOT.LD. 40.Opsf DUR.FAC. 1.25 SPACING 24.0" RIGHT RAKE = V414 RIGHT JIG = 11'4"4 SEQ = 30619 SCALE=0.3262 REF DATE 06-01-2005 DRWG O/A LEN. 240400 TYPE SPeC Job:(RDVRML30) /Rod VenvAlo Mtetro / Bt Top chord 2x4 SP #1 Bot chard 2x4 SP #1 Webs 2x4 SP #3 Deflection meets U360 live and U240 total load. M 3X41A ]is THIS DWG, PREPARED BY E JOB DESIGNER PROGRAM FROM TF LAYOUT 120 mph wind, 9.94 ft mean hgt, ASCE 7-98, CLOSED bidg, not located within 4.50 It from roof edge, CAT 11, EXP B, wind TC DL=5.0 psf, wind BC OL=5.0 pall. H = recommended connection based on manufacturer tested capacities and calculations. Conditions may exist that require different connections than indicated. Refer to manufacturer publication for additional information. TC1 TC2 I 11' 2C "{ rL- W10 + 4'11'6 + 2C I" 4'11'6 1 scl RV-96W 250# HaShnpson HUS26 w/(4) led, 0.16M.5- nab in Truss wA14) led, 0.16ZaS'raft In Grder Girder fs (2) 1.50x 5.50 SP SofldSewn 6714 2'2'4 24'4' LEFT JIG = 11'87 DESC. = B1 PLT. TYP.-WAVE FBC/TP11995(STD) QTY= 1 TOTAL= 1 THIS DRAWING SHOULD BE APPROVED BY A REGISTERED PROFESSIONAL ENGINEER BEFORE USE. SEE PAGE A100 FOR GENERAL NOTES,IMPORTANT SPECIFICATIONS AND WARNINGS. — TC3 11' — .INEiH H. r- Iy te�P.L MIDGE Ilet SC2 %-10640 U=2649 'Aga- q w SEAT PLATE RE. `' U N O 01W--G 200 MOUNT DORA, FL 32787 FL, REG.18243 RIGHT RAKE = 1'4"14 RIGHT JIG = 11'8"7 SEQ = 30624 REV. 7,02.0527.10 SCALE =0.3262 TC LL 20.Opsf REF TC DL 10.0psf BC OL 10.0psf BC LL O.Opsf TOT.LD. 40.Opsf DUR.FAC. 1.25 SPACING 24.0" ' DATE 0"1-2005 O/A LEN. 240400 TYPE hips o:(KUVKMUM Nod Vermdho Metro / A14 Top chard 2x4 SP #1 Bot chard 2x4 SP #1 V*bs 2x4 SP #3 THIS DWG. PREPARED BY THE ALPINE JOB DESIGNER PROGRAM FROM TRUSS MFR'S LAYOUT 2 Complete Trusses Required F—=� 120 mph DLL 015.00 ft mean hgt ASCE 7-98, CLOSED bklg, Located anywhere in roof, CAT II, EXP B, wind TC DL=5.0 pal, NAILING SCHEDULE: (10d box nails) wind BCBOT CHORD: 1 ROW 12" o.c. 41 hip supports 7-M jacks with no webs. WEBS 1 ROW @@ Po.c. USE EQUAL SPACING BETWEEN RCM AND STAGGER NAILS Deflection meets U360 live and L/240 total bad. IN EACH ROW TO AVOID SPLITTING. r TC1 (A) #3 or better scab brace. Same site & 80% length of web member. Attach with 10d nails C 6" OC. Left side jacks have 7.0.0 setback with 0-2-0 cant and 1-4-0 overhang. End jades have 7-0-0 setbackwith 0.40 card and 1-4-0 overhang. Right side jacks have 7-&0 setback with 0.0.0 cant and 14-0 overhang. TC4 —� r zr T ..I 1----3'1a"14—.(�-3'1.2 } 87'5 ♦ 775 ♦ $75 - - Y1 2 .}. T10.14—�( 12 T 4 p � 3x6(A1) hm 16V I;r dw TC2 (A) TC3 T bs 7'10'13 ♦19'3 _ V5.3 4-r10'13 ♦ 6r2--� +;:7 Lan��n�� i��S(� 20 FlC1 BC2 Rv=1o21rr �zst# a• } Rva40450 t>=1o6e# t4l ec3 LEFT RAKE = 1W14 LEFT JIG = T5"14 DESC. = A14 PLT. TYP.-WAVE FBC/TPI1995(STD) QTY= 1 PLIES= 2 TOTAL= 2 THIS DRAWING SHOULD BE APPROVED BY A REGISTERED PROFESSIONAL ENGINEER BEFORE USE. SEE PAGE A100 FOR GENERAL NOTES,IMPORTANT SPECIFICATIONS AND WARNINGS.. UN 0 1*33 2045 BC4 Rv-1427# Lh39dM VY�fr SEAT PLATE REfNT' H { 'FL 3=%� FL. REG.1-243 REV. 7,02.0527.10 TC ILL 20.Opsf TC DL 10.0psf BC DL 10.Opsf BC ILL O.Opsf TOT.LD. 40.Opsf DUR.FAC. 1.255 SPACING 24.0" RIGHT RAKE=1'4"14 RIGHT JIG = T5"14 SEQ = 30666 SCALE=0.2059 REF DATE 06-01-2005 DRWG O/A LEN. 38 TYPE Vermdfio AMatro / Al 3 THIS PREPARED BY THE ALPINE JOB DESIGNER PROGRAM FROM TRUSS MFR'S LAYOUT Top chord 2x4 SP #1 :TC2 2x6 SP 91: Bot chord 2x6 SP #1 Webs 2x4 SP 93 SPECIAL LOADS --(LUMBER DUR.FAC.=1.25 / PLATE DUR.FAC.=1.25) TC - From 60 PLF at -1.33 to 60 PUP at 7.00 TC - From 127 PLF at 7.00 to 127 PLF at 13.54 TC - From 60 PLF at 13.54 to 60 PLF at 39.33 BC - From 4 PLF at -1.33 to 4 PLF at 0.00 BC - From 20 PLF at 0.00 to 20 PLF at 7.00 BC - From 44 PLF at 7.00 to 44 PLF at 13.54 BC - From 20 PLF at 13.54 to 20 PLF at 38.00 BC - From 4 PLF at 38.00 to 4 PLF at 39.33 SC - 484 LB Cow Load at 7.00 BC - 1860 LB Conc. Load at 13.54 TI T lM-5 2 Com Required NAILING SCHEDULE: (10d box nails) TOP CHORD: 1 ROW 12' o.c. BOT CHORD: 1 ROW 12" o.c. WEBS 1 ROW 4" o.c. USE EQUAL SPACING BETVNEEN ROWS AND STAGGER NAILS IN EACH ROW TO AVOID SPLITTING. 120 mph wind, 15.00 ft mean hgt, ASCE 7-96, CLOSED bidg, not located within 4.50 ft from roof edge, CAT 11, EXP B, wind TC OL=5.0 pst, wind BC DL=5.0 psf. (A) Continuous lateral txadng equally spaced on member. Deflection meets L/360 We and L1240 total load. Calculated vertical deflection is 0.52" due to five load and 0.51" due to dead bad at X = 1364. fL' TC1 TC2 TC3 r TC4 13w + 52 127 4'1'14 2'10'2 611'12 1 P VW4 @Tto Kpwi A. ETHKEHLEatl RE, 16 I`;- 6710 + 611'12 611'12 fir + B8'2 :t1/,J 510'!119 icy Ag _�IFLWEI ��/D L5"t T I6w 6 24'9'B uw 18 L scl IW-36370 U"1043K1VW6' SEAT PLATE REQUIRED LEFT RAKE = 1'4"14 LEFT JIG = T5"14 DESC. = Al PLT. TYP. WAVE FBC/TPI1 6C2 -}- BC3 RA SEAT PLATE �r W4 FL 32757 M AEG. low QTY= 1 PLIES= 2 TOTAL= 2 THIS DRAWING SHOULD BE APPROVED BY A REGISTERED PROFESSIONAL ENGINEER BEFORE USE. SEE PAGE A100 FOR GENERAL NOTES,IMPORTANT SPECIFICATIONS AND WARNINGS. REV. 7.02.0527.10 TC LL 20.Opsf TC DL 10.0psf BC DL 10.Opsf BC LL O.Opsf TOT.LD. 40.Opsf DUR.FAC. 1.25 SPACING 24.0" RIGHT RAKE = 1'4"14 RIGHT JIG = 12'11 "3 SEQ = 30632 SCALE=0.2059 REF DATE 06-01-2005 DRWG O/A LEN. 38 TYPE spec Job:(ROVRML30) /Rod Vemnillio /Metro / Al Top chord 2x4 SP #1 Bat chord 2x4 SP #1 ftbs 2X4 SP #3 Deflection meets L/360 live and L/240 trial bad. THIS DWG. D BY THE ALPINE JOB DESIGNER PROGRAM FROM TRUSS MFR'S 120 mph wind, 9.61 It mean hgt, ASCE 7-98. CLOSED bldg, not located within 4.50 ft from rod edge, CAT 11, EXP B, wind TC DL=5.0 psf, wind BC OL=5.0 psf. (A) Continuous lakmA bracing equally spaced on member. Or t x4 03 or better'T" brace. 80% length of web member. Attached with 8d nals Q 6" OC. r TC1 .I TC2 TC3 TC4 9 I 20 9 ---� F+— 4'10'14 . i 4'1'2 { 6712 + ed"8 + e9'12 + 4'1"2 + 410'14 4 12 USv 3X4 99 3X4 VV2 (A) (A) 3X4 Wl v%G VY6 3X6(A„ X6 } 1 }� 3X4 5 3X4 I I tee• 21,4• 6T*45712 + 6r4 + 972 3e H. EHL79% P.E. MR1DuE PLACE W=567# U=18Udi F lit Rv1848# U= # VY 4' BC? Rv790 t*2/20'� v Jj N 0 LUU� IA SEAT P?E REQr.".. ED LEFT RAKE = 1'4"14 LEFT JIG = 97'2 DESC. = Al2 PLT. TYP: WAVE FBC/TPi1 QTY= 1 TOTAL= 1 THIS DRAWING SHOULD BE APPROVED BY A REGISTERED PROFESSIONAL ENGINEER BEFORE USE. SEE PAGE A100 FOR GENERAL NOTES,IMPORTANT SPECIFICATIONS AND WARNINGS. MOUNT DORA, FL 32757 FL. REG. i 3243 REV. 7.02.0527.10 TC LL 20.OPSf TC DL 10.OPSf BC DL 10.0PSf BC LL O.OPSf TOT.LD. 40.OPSf DUR.FAC. 1.25 SPACING 24.0" RIGHT RAKE = 1 W 14 RIGHT JIG = 97"2 SEQ = 30725 SCALE =0.2059 REF DATE 06-01-2005 O/A LEN. 38 r Trc D. kmu V mmN ) MOO Vel 1110 /MBIIO / Al 1 THIS OWG. PREPARED BY THE ALPINE JOB DESIGNER PROGRAM FROM TRUSS MFR'S LAYOUT Tap chard 2x4 SP 91 120 mph wind, 10.13It mean hgt ASCE 7-96, CLOSED bldg, not located within 4.50 It from roof edge, CAT 11. EXP B. wind TC Bot chord (4 SP !Ki 3 DL=5.0 psf, wind BC DL=5.0 Webs 2x4 SP psf. Deflection meets L/360 live and L /240 trial load TCt + TC2 Tp TC4 4 ♦ 13T 37 ♦ 122' R10"14 ♦ 01'2 4'8"7 --4--- 4'6'11 — 4WIS 37 67'10 �{ 9C6 T T 4 12 SXa 3 X4 5X8 v VV10 3X4 If G 3X4 W4 3X6(Ai) �Vlfl23X8(At) 3-t6� 1 36 ICI 872 C4'15 ♦ 4'6'11 ♦ 44'15 ♦ 35'8 ♦ 58'2 WON H �y f ec, O RIDut-i Pi AAR RY-16080 1k4290 VV-r I z T BC3 Rv.151ft U-3W WW SEAT PLATE REQUIRED SEAT PL4TF.REQ+ 0 fj ' LEFT RAKE = 1W14 LEFT JIG = 97'2 DESC.= Al PLT. TYP.-WAVE FBC/TPI1 QTY= 1 TOTAL= 1 THIS DRAWING SHOULD BE APPROVED BY A REGISTERED PROFESSIONAL ENGINEER BEFORE USE. SEE PAGE A100 FOR GENERAL NOTES,IMPORTANT SPECIFICATIONS AND WARNINGS. REV. 7.02.0527.10 TC LL 20.Opsf TC DL 10.0psf BC DL 10.0pSf BC LL O.OPSf TOT. LD. 40.Opsf DUR.FAC. 1.25 SPACING 24.0" RIGHT JIG = 12'11"3 SEQ = 30746 SCALE=0.2129 REF DATE 06-01-2005 DRWG O/A LEN. 38 TYPE SP2C /Rod VermdRo Metro / All0 THIS DWG. PREPARED BY THE ALPINE JOB FROM TRUSS MFR'S LAYOUT Top chord 2x4 SP #1 Bat chard 2x4 SP #1 Webs 2x4 SP #3 Deflection meets U380 live and L/240 total load. TCt I+90'10 ♦ 4'11"6 ♦ 710'4 120 mph wind, 9.94 R mean hgt. ASCE 7-98, CLOSED bldg, not located within 4.50 It from roof edge. CAT 11, EXP B, wind TC DL=5.0 psf, wind BC DL=5.0 psf. (A) Continuous lateral bracing equally spaced on member. Or 1 x4 #3 or better "I" brace. 80% length of web member. Attached wwlifth 8d nails C G' OC. TC2 TM le +{ 1r 16V♦ 21,4" K At*14 .0IETH N. I- =H EHLr9S, P.E.1=}710'4 81'2-58 3e iJFC.VMR'0 ui_AE SCt R Rv=535# U-1800 4' w1905# U=504# VV-4' BC2 I tt T BC3 Rv=771# Uz20<'ii JY6JUI\ Q tf 208.1C SEAT PLATE RECURM LEFT RAKE = 1'4714 LEFT JIG = 11'8"7 DESC.= A10 PLT. TYP: WAVE FBC/TPI1 QTY= 1 TOTAL= 1 THIS DRAWING SHOULD BE APPROVED BY A REGISTERED PROFESSIONAL ENGINEER BEFORE USE. SEE PAGE A100 FOR GENERAL NOTES,IMPORTANT SPECIFICATIONS AND WARNINGS. MOUNT UDR, FL 3RO 57 FL. REG. 18243 REV. 7.02.0527.10 TC LL 20.Opsf TC DL 10.0PSf BC DL 10.0PSf BC LL O.OPSf TOT.LD. 40.Opsf DUR.FAC. 1.25 SPACING 24.17' RIGHT RAKE=1'4"14 RIGHT JIG = 11'8'7 SEQ = 30728 SCALE=0.2059 REF DATE 06-01-2005 DRWG O/A LEN. 38 TYPE hips /Rod Vermifio !Metro / A9 G. PREPARED BY THE ALPINE JOB DESIGNER PROGRAM FROM TRUSS MFR'S LAYOUT Top chord 2x4 SP 91 Bat chord 2x4 SP #1 Webs 2x4 SP #3 120 mph wind, 10.13 ft mean hgt, ASCE 7-96, CLOSED bidg, not located within 4.50 R from root edge, CAT 11. EXP B, wind TC DL=5.0 psf, wind BC DL=5.0 psf. Deflection meets L/360 live and L/240 total load. r TC1 �• TC2 i TC3 r TC4 11' ♦ 13'8' = ♦ 127 6710 4'1 I's 6'11'12 68'4-�}r=+}.--- 666 5'7^10 .{ 5X6 5X8lR) ,2 Op— '� 3X4 V�i >:4 O .. W4 VA M1 VV1 VJI W11 W(Al)3X8(Ai) 38 51'2 68.4 684 sa-2 " r+ 1 EHIMP .J ,? P.E. PLACE "18080 U-420 W+8' T' Rv=1518# l'=3950 Wig• SEAT PLATE REQUIRED SEAT PLATE R94jo Q ii r �.OQ LEFT RAKE = 1'4"14 LEFT JIG = 11'8'7 DESC. = A9 PLT. TYP.-WAVE FBCJTPII QTY= 1 TOTAL= 1 THIS DRAWING SHOULD BE APPROVED BY A REGISTERED PROFESSIONAL ENGINEER BEFORE USE. SEE PAGE A100 FOR GENERAL NOTES,IMPORTANT SPECIFICATIONS AND WARNINGS. MOUNT DORA, Ft &^75t FL. REG.18243 REV. 7.02.0527.10 TC LL 20.Opsf TC DL 10.0psf BC DL 10.0pSf BC LL O.Opsf TOT.LD. 40.Opsf DU R. FAC. 1.25 SPACING 24.0" RIGHT JIG = 12'11 "3 SEQ = 30749 SCALE =0.2129 REF DATE 06-01-2005 DRWG O/A LEN. 38 TYPE Spec 0:(KUVKML0Ut /K00 VWMAHO WWO / AO Top chord 2x4 SP # 1 Bot chord 2x4 SP 91 V*bS 2x4 SP #3 TH15 UWG. PREPARED BY THE ALPINE JOB UESIGNER PROGRAM FROM TRUSS MFR'S LAYOUT 120 mph wind, 10.27 ft mean hgt, ASC E 7-96, CLOSED bidg, not located within 4.50 ft from roof edge, CAT 11, EXP B, wind TC DL=5.0 psf, wind BC DL=5.0 psf. Deflection meets U360 live and U240 total bad fL-- TC1 I TC2 + TC3 I 13' } 12 I 13' TIM 610'4 6'1'12 5'11"6 I T0"10� 1. - 21'73 --+; i..f` ( t; j c 17; e'6' 6'1'2 �}�V4'13—+-ZW15-+--5'10'4 81'2 6G--- tom- f� PrH:rE i i s 36' ��, � �R�����. GLACE ES t;— BC1 + SC2 + SC3 Rv=472# U=1S0# 4' RV=1991# U-522# W-5'11 Rva747# U-21W, vr-r SEAT PLATE REG?i1{ N MOUNT DO A, F� 32?5T FL. REG.18243 LEFT RAKE = 1'4" 14 RIGHT RAKE = V4" 14 DE C. = A8 3'9"12 RIGHT SEQ 1 0731 PLT. TYP.-WAVE FBCfTPI1995(STD) QTY= 1 TOTAL= 1 REV. 7.02.0527.10 SCALE=0.2059 THIS DRAWING SHOULD BE APPROVED BY A REGISTERED PROFESSIONAL ENGINEER BEFORE USE. SEE PAGE A100 FOR GENERAL NOTES,IMPORTANT SPECIFICATIONS AND WARNINGS. TC LL TC DL BC DL BC LL TOT.LD. 20.Opsf 10.0psf 10.0pSf O.OPSf 40.Opsf REF DATE 06-01-2005 DRWG OJA LEN. 38 DUR.FAC. 1.25 SPACING 24.0" TYPE hips b:(RDVRML30) /Rod % Top chord 2x4 SP #1 Sot chard 2x4 SP #1 V*bs 2x4 SP 93 /Metro / A7 THIS DY,/G. PREPARED BY THE ALPINE JOB DESIGNER PROGRAM FROM TRUSS MFR'S LAYOUT 120 mph wend, 10.27 It mean hgt, ASCE 7-98, CLOSED bldg, not located within 4.50 ft from roof edge, CAT 11, EXP B, wind TC DL=5.0 pelf, wind BC OL=5.0 psf. Detlectiml meets L/360 five and L/240 total load. r TC, TC2 } TC3 I 13' } 12 I 13' I 7n'10 { sire I tr s sirs 70•,0---{ I:r �• + 61'2 + + + 6'1-2 + ee•— > T'H H.'EHL{'.S� P.EONB. BCI + BC2 A- DGE PLACE Rv=1606# U-421W ;;a- BO ---f RoI5189 U-A0 VJ S' SEAT PLATE REQUIRED SEAT PLATE RE-O>JJEMI (! 2005 FOUNT DOWL, 3275T FL REG.18243 LEFT RAKE = 1'4'14 LEFT JIG = 13712 DESC. = A7 RIGHT JIG = 13'9 12 PLT. TYP: WAVE FBClTPI1995(STD) QTY= 1 TOTAL= 1 REV. 7.02.0527.10 SEQ = 30752 SCALE=0.2129 TC LL 20.Opsf REF TC DL 10.0pSf DATE 06-01-2005 THIS DRAWING SHOULD BE APPROVED BY A REGISTERED BC DL DI 10.OpS f _ DRWG PROFESSIONAL ENGINEER BEFORE USE. SEE PAGE A100 O..Ops FOR GENERAL NOTES,IMPORTANT SPECIFICATIONS AND BC O/A LEN. 38 WARNINGS. TOT.LD. 40.Opsf DUR.FAC. 1.25 SPACING 24.0" ITYPE hips ":(KUVKMIJU) /KOO VerrMNO IMO O / Ad Tap chord 2x4 SP #1 Bot chord 2x4 SP #1 Vvebe 2x4 SP #3 Deflection meets U360 Gve and L/240 total load. THIS DVYG. PREPARED BY THE ALPINE JOB DESIGNER PROGRAM FROM TRUSS MFR'S LAYOUT 120 mph wind, 10.61 ft mean hgt, ASCE 7-96, CLOSED bidg, not located within 4.50It from roof edge, CAT 11, EXP B, wind TC DL=5.0 psf, wind BC OL=5.0 pet. (A) Continuous lateral bracing equally spaced on member. Or 1 x4 #3 or better'T" brace. 80% length of web member. Attached with 8d nails @ 6" OC. r TC1 .I+ TC2 + TC3 TC4 jam--8'0'5 } ett'11 I 8' G1P11 I=1= 7e' + es',s + &&7 Fes= I 38 8Ct SC2 Rv-390# U-180N 4' RV•19520 Ux503# t5wil LEFT RAKE = 1'4 14 LEFT JIG = 15"1" DESC. = A6 PLT. TYP.-WAVE FBC/TPI1 1 TOTAL= 1 THIS DRAWING SHOULD BE APPROVED BY A REGISTERED PROFESSIONAL ENGINEER BEFORE USE. SEE PAGE A100 FOR GENERAL NOTES,IMPORTANT SPECIFICATIONS AND WARNINGS. 15' TC5 Mrs +{ 7714 Tom- TH H.'ERFS, P.E. NENGE PLACE R-8110 U=237#' VO6 r SEAT PLATE REOL.9RECjUN 0' 9 2005 an MOUNT DGRA, FL 32MI FL. REG.18243 RIGHT RAKE =1 414 RIGHT JIG x 15`11" SEQ = 30734 REV. 7.02.0527.10 SCALE =0.2059 TC LL 20.OpSf REF TC DL 10.0PSf DATE 0"1-2005 BC DL 10.0PSf DRWG BC LL O.OPSf TOT.LD. 40.OPSf O/A LEN. 38 DUR.FAC. 1.25 SPACING 24.0" TYPE hips /Metro / A5 THIS DV%G. ALPINE JOB DESIGNER PROGRAM FROM TRUSS MFR'S LAYOUT Top chord 2x4 SP 01 Bot chard 2x4 SP #1 Webs 2x4 SP 93 120 mph wind, 10.61 It meld hgt, ASCE 7-98, CLOSED bldg, not located within 4.50 It from rod edge, CAT 11. EXP B, wind TC DL=5.0 psf, wind BC DL=5.0 psf. Deflection meets U360 live and 1-1240 total load. r TCt TC2 + TC3 I 19 I e I t- —875 I s1r1/ I 4- { r I elrs 12 4l7 1 �«Ail ]'16 1=r 7r I- Rv16080 U•427N1;;8• BC1 SEAT PLATE REQUIRED LEFT RAKE = 1'414 LEFT JIG = 15'11" DESC. = AS PLT. TYP.-WAVE FBC/TPI1 TC4 •16 8'0.10 —I /r ro 1<6(A1) 39 T1.2 4' —Tt•2 T8• ( _— �Iz w -K NNt I H. EHV--RS, F.E. + BC2 130 NH 1D- of QTY= 1 TOTAL= 1 THIS DRAWING SHOULD BE APPROVED BY A REGISTERED PROFESSIONAL ENGINEER BEFORE USE. SEE PAGE A100 FOR GENERAL NOTES,IMPORTANT SPECIFICATIONS AND WARNINGS. Rv—i'JS�. i4w f1 SEAT PLATF nE0U':':E0 jUN 9 6 2005 MOUNT DORA, FL 31-757 FL. REG.18243 RIGHT JIG = 1511" SEQ = 30755 REV. 7.02.0527.10 SCALE=0.2129 TC ILL 20.Opsf TC DL 10.0psf BC DL 10.0psf BC LL O.Opsf TOT.LD. 40.Opsf DUR.FAC. 1.25 SPACING 24.0" REF DATE 06-01-2005 DRWG O/A LEN. 38 TYPE Job:(RDVRML30) /Rod Vermft Metro / A4 Top chord 2x4 SP #1 Bot chord 2x4 SP #1 V*bS 2x4 SP #3 THIS DWG. JOB DESIGNER PROGRAM FROM TRUSS MFR'S LAYOUT 120 mph wind, 10.94 ft mean hgt, ASC E 7-98, CLOSED bldg, not located within 4.50 It from roof edge, GAT II, EXP B, wind TC DL=5.0 psf, wind BC DL=5.0 psf. Deflection meets L/360 live and L/240 total load. TCt .}. TC2 A. TM TC4 .+" TC5 ,T 4' ♦ 1T I �— 6 Y3 ♦ 55.1 ♦ 94.12 547 ♦ 678 - •{ 5JC6 12 3X 10 5X6 4 v ws vw 5xe 3x4 Inn W4 vw 0 3X8(At) 1 yiXB(A1)� 124'13 .{. 25 r3 1=1- —8'S• 3'5'1568.15 ♦ 3'10'4 }" 8'1'2 Mr EHL^QSi P.E. NBM tik'LADE R�321# U=180N Nh81 9C1 ecz + ec3 A. Rw991# LY264N 'JWB' SEAT PLATE REQt1iRED Rw1899# LW98lf N/ 5'11 SEAT PLATE REWREJU iN MQUKDORA, FL 32767 R..REG.18243 LEFT RAKE = 1'4"14 LEFT JIG = 160"5 RIGHT RAKE = 1'4"14 DESC. = A4 RIGHT JIG = 18'0"5 SEQ = 30737 PLT. TYP.-WAVE FBC/TPI1995(STD) QTY= 1 TOTAL= 1 REV. 7.02.0527.10 SCALE=0.2059 TC LL 20.Opsf REF DATE 06-01-2005 TC DL 10.Opsf THIS DRAWING SHOULD BE APPROVED BY A REGISTERED 0.OpS f BC DL 10.0pS DRWG PROFESSIONAL ENGINEER BEFORE USE. SEE PAGE A100 FOR GENERAL NOTES,IMPORTANT SPECIFICATIONS AND BC LL O/A LEN. 38 WARNINGS. TOT.LD. 40.Opsf DUR.FAC. 1.25 SPACING 24.0" TYPE hips [!.\RVYRMIJVr/RW YOlf wjffleQ !^a Top chard 2x4 SP 91 Bot chord 2x4 SP #1 V*bs 2x4 SP #3 N 3} fn THIS DWG. PREPARED BY THE ALPINE JOB DESIGNER PROGRAM FROM TRUSS MFR'S LAYOUT 120 mph wind, 10.94 It mean hgt, ASCE 7-98, CLOSED bldg, not located witfWl 4.50 It from root edge, CAT 11. EXP B, wind TC DL=5.0 pat, wind BC DL=5.0 psf. Deflection meets L/360 live and L/240 total load TC1 TC2 TC3 —.�-- TC4 TC5 1T 4' ♦ 1T 673 5'5'1 ♦ 514'124' 54'7 678 �{ 36 {'.1= 8'6' 8714 3'10"4 ♦ 8'1'2 {�= I 36 I-— Bc1 .}• BC2 Rv-16050 U-425# vwir SEAT PLATE REQUIRED LEFT RAKE = 1'4"14 LEFT JIG = 18'0"5 DESC. = A3 PLT. TYP.-WAVE FBC/TPI1 QTY=1 TOTAL= 1 THIS DRAWING SHOULD BE APPROVED BY A REGISTERED PROFESSIONAL ENGINEER BEFORE USE. SEE PAGE A100 FOR GENERAL NOTES,IMPORTANT SPECIFICATIONS AND WARNINGS. ST H.; Hrf99) P.E. BC3 BC4 —mayjj {� SEAT TEREOl1fRZ -N Q- 6 Zufl5 MOUNT DORA, AFL 327sy REV. 7.02.0527.10 FL REG.19243 RIGHT RAKE = 1'414 RIGHT JIG = 1875 SEQ = 30758 SCALE=0.2059 TC LL TC DL BC DL BC LL TOT.LD. 20.Opsf 10.Opsf 1 O.Opsf O.Opsf 40.Opsf REF DATE 06-01-2005 DRWG O/A LEN. 38 DUR.FAC. 1.25 SPACING 24.0" TYPE hips WtKUV KMLJU] IK013 Vlrm11110 /Metro / A2 Top chord 2x4 SP #1 Bot chord 2x4 SP 91 Webs 2x4 SP #3 TC1 THIS DAOG. PREPARED BY THE ALPINE JOB DESIGNER PROGRAM FROM TRUSS MFR'S LAYOUT 120 mph wind, 11.27 ft mean hgt, ASCE 7-98, CLOSED Mg. not located within 4.50 ft from root edge, CAT II, EXP B. wind TC DL=5.0 psf, wind BC DL=5.0 pal. Deflection meets U360 five and L/240 total load. TC2 --. i TC3 TC4 F---Sim ♦ sm erg erg sow -f- 61018--� 3) Ti3 L Rv=1818 U-1800 i;;-r- BC1 SEAT PLATE REWIRED LEFT RAKE = 1'4"14 LEFT JIG = 20'1 "10 DESC. = A2 PLT. TYP.-WAVE FBC/TP11 2r1U'4 — .r ♦ 9'1.2 ♦ 9'17 H (J 4 � P.E. + �2 + �, � . ONBRIDGE ?LADE SEAT PLATE U=lE E 11'13 SEAT PLATE REVUtRI: ( N 0 � j 005 SEAT PLATE REWIRED cVi+•1! QTY= 1 TOTAL= 1 THIS DRAWING SHOULD BE APPROVED BY A REGISTERED PROFESSIONAL ENGINEER BEFORE USE. SEE PAGE A100 FOR GENERAL NOTES,IMPORTANT SPECIFICATIONS AND WARNINGS. MOUNT DORA, F! 32757 FL REG.18243 RIGHT RAKE = V414 RIGHT JIG = 20'1"10 SEQ = 30740 REV. 7.02.0527.10 SCALE=0.2059 TC LL 20.Opsf REF TC DL 10.Opsf DATE 06-01-2005 BC DL 10.Opsf DRWG BC LL O.Opsf TOT.LD. 40.Opsf O/A LEN. 38 DUR.FAC. 1.25 SPACING 24.0" TYPE Comn i0:(KUVKMLJU) /KOO Verrtlrrro Metro / Al Top chord 2x4 SP # 1 Bot chord 2x4 SP 91 Webs 2x4 SP #3 TC1 THIS DWG. PREPARED BY THE ALPINE JOB DESIGNER PROGRAM FROM TRUSS MFR'S LAYOUT 120 mph wind, 11.27 ft mean hgt, ASCE 7-98, CLOSED bldg, not located within 4.50It from roof edge, CAT 11, EXP B, wind TC DL=5.0 psf, wind BC OL=5.0 psf. Deflection meets L/360 Gve and L/240 total Toad. TC2 + TC3 TC4 19 19, I---eloa 1. 6'0•7 ere "}- srl -}• 677 eloa-� fftt - 9T + 91'2 L RwlM# 11=424#!';—,w BC1 SEAT PLATE REQUIRED LEFT RAKE = 1'4"14 LEFT JIG = 20'1 "10 DESC. = Al PLT. TYP.-WAVE FBC/TPI1 1?w� 8' Tso+ BC` R�1 � AD S I Rg ?ACE SEAT PLATE REQUIRED JUN 0 b 2005 QTY= 4 TOTAL= 4 THIS DRAWING SHOULD BE APPROVED BY A REGISTERED PROFESSIONAL ENGINEER BEFORE USE. SEE PAGE A100 FOR GENERAL NOTES,IMPORTANT SPECIFICATIONS AND WARNINGS. MOUNT DORA, Ft .3275? RIM d♦♦� RIGHT JIG = 20'1 "l0 SEQ = 30743 REV. 7.02.0527.10 SCALE=0.2059 TC LL 20.Opsf REF TC DL 10.Opsf BC DL 10.Opsf BC LL O.OPSf TOT.LD. 40.Opsf DUR.FAC. 1.25 SPACING 24.0" DATE 06-01-2005 DRWG O/A LEN. 38 TYPE, comn