408 E Mattie St 03-2864 Fire system for paint booths CITY OF SANFORD PERMIT APPLICATION p Permit # : I 0 ^ ` Date: Job Address: -IC) £ YV1 Q } -f-7 e- s f Description of Work: G t YL-. Sv S 4 M \ h ONl a-'r Q CQ cS''V Historic District: Zoning: Value of Work: $ o`l400 Permit Type: Building Electrical Mechanical Plumbing Fire Sprinkler/Alarm Pool 1=vte SY S_ Electrical: New Service - # of AMPS Addition/Alteration Change of Service Temporary Pole Mechanical: Residential Non -Residential Replacement New (Duct Layout & Energy Cale. Required) Plumbing/ New Commercial: # of Fixtures # of Water & Sewer Lines # of Gas Lines Plumbing/New Residential: # of Water Closets Plumbing Repair - Residential or Commercial Occupancy Type: Residential Commercial Industrial Total Square Footage: Construction Type: # of Stories: # of Dwelling Units: Flood Zone: (FEMA form required for other than X) Parcel #: (Attach Proof of Ownership & Legal Description) Owners Name & Address: 1-fUwr3 1q__14.-f-v &d-V Phone: Contractor Name & Address: P DV /4CC;r (^ I YLC C,ZL-kE 1KeA'I- 5-• L-4urel av S 'ry-, c v State License Number: U Q t{ o-i ` S 6-15 u Phone & Fax: 32 i — (o (. Contact Person: Pa t^ Ny l u v > Phone: Bonding Company: _ Address: Mortgage Lender: Address: Architect/Engineer: Phone: Address: Fax: Application is hereby made to obtain a permit to do the work -and i2taticU 8 J@Qa. 1 cerdtf, ihaino work or installation has commenced prior to the issuance of a permit and that all work will be performed-to:meet standards of all laws regulating construction -in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES-;B.OILERS; HEATERS, TANKS, and AIR CONDITIONERS, etc. s; OWNER'S AFFIDAVIT: I certify that all of the foregoing in io is ur e a work'willbe.done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR ARE O ICE OE`C04iMENCEMENT MAY RESULT IN Y I1;)?. PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING',. CONSULT WITH YOUR LENDER Olt AI'T ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the require m nts of Florida Lin La IFSIII Signature of Owner/ Agent Date Qiature of Contractor/Agent Date V-,eCt V-\ NtJVa r Print Owner/Agent' s Name Print ntract r/Agent s ame Signature of Notary - State of Florida Date Sign ture of Notary -State of orida S0"' P*e JUSTIN EARLY MY COMMISSION # DO 242141 EXPIRES: August 23, 2007 Owner/Agent is _ Personally Known to Me or Contractor/Agent is _ Personally Known to FMAb' r a Bonded Thru Budget Notary Services Produced ID MM Q Produced ID APPLICATION APPROVED BY: Bldg:„ % —Zoning: Utilities: FD: U3 Initial & Date) (Initial & Date) (Initial & Date) (Initial & Date) Special Conditions: W<-( i,0 SANFORD FIRE DEPARTMENT FIRE PREVENTION DIVISION 300 N. Park Ave., Sanford, Fl. 32771 / P. O. Box 1788, Sanford, FI.32772 407 302-2520 / FAX (407) 330-5677 Pager (407) 9I8-0395 Plans Review Sheet Date: September 9, 2003 Business Address: 408 E. Mattie Street Paint Booth Business Name: Hunts Auto Body Ph. ( ) Contractor: Advance Fire Equipment Ph. (407) 699-6990 FAX (407)324-8266 Reviewed [ ] Revtewedwth eollllment (mX'J Rejected [ I Reviewed by: Timothy Robles, Fire Protection Inspector/Plans Examin Comment: Install new Paint booth Fire Suppression system. 1. PCI-70 ABC 2. PCI-17 ABC 3. #300 PIPE Dump /Function test required 1 VA a.. F . tF/R_E='EQ[//P, MENtT, /NC a ` •> HUNT AUTOBODY SHOP 408 E. MATTIE SANFORD, FL. PLANS TO INSTALL A PYRO CHEM FIRE SYSTEM USING PCI 70 ABC AND PCI 17 ABC CYLINDERS. BOTH CYLINDERS WILL ACTIVATE AT THE SAME TIME. THE PCI 70 WILL PROTECT THE WORK AREA AND THE PCI 17 WILL PROTECT THE EXHAUST DUCT AND THE PLENUM AREA. TEFLON TAPE WILL BE USED ON THE PIPE THREADS. 300 # PIPE FITTINGS WILL BE USED. AkBELL WILL RING WHEN THE SYSTEM IS ACTIVATED. D SEP 0 115 S. Laurel Ave. • Sanford, FL 32771 - (407) 699-6990 • (888) 324-8303 • FAX (407) 324-8266 r Large Full Back Draf t Piant Spray Booth Center Nozzle Placement No, Equipment 1 PCI-70ABC 2 PCI-17ABC 3 NV -WA Nozzle 4 NV-P1 Nozzle 5 NV-DP2 Nozzle 6 T-10 Time Delay 7 4' X 6' Nozzle Placement Zone For All NV -WA Nozzles BRAVING Tr" d_.ing and all d.slgns arm dots th.r.an sh.a rot ee duptkatud, w.d. or Ifettas.d to °tlrrsSIZEforpracur.n.nt r eny oth.r purpose. eae.pt as °thrr.ise autharte.e by contr..tthout A Britten permission of Pyro Chen, Inc. As nproductbns fhetl Mar tNa roues. UMess athereise specined Pyro Chen dlnensbns are M inches 301 Division St. Boonton, NJ 07005 Date Draum 8/1/9a 1I11e Large Full Back Draft Taterances are Paint Spray Booth 2 Ptoce d.cirot •/- .BI Scale: None Center Nozzle Placement3PtocedreWQ1 •/- A03 fractions VPSB-98003A ev. Angtes •/- t DWrI. RCK APP THE PCI 70 ABC WILL FOLLOW PAGE 3-13 PIPING REQUIRMENTS. THE PCI 17 ABC WILL FOLLOW PAGE 3-7 PIPING REQUIRMENTS Chapter 2 —.Components Page 2-2 NOZZLES Nozzles have been developed for Vehicle Paint Spray Booth protection. Each nozzle has been designed for use in certain areas of the booth. The Model NV -WA nozzle is used for overhead application in the booth work area. The Model NV-P1 nozzle is used for overhead application in the back - draft plenum or downdraft pit area. The Model NV-UF nozzle is used for overhead application in the underfloor plenum area. The Model NV-D/P2 nozzle is used for horizontal (end position) application in the pit/duct area. The Model NV-D/P2 nozzle is also used for end position application for exhaust duct protection. The Model N-DCT nozzle is also an alter- nate nozzle used for exhaust duct protection. The Model N-DCT nozzle can only be used on 15 lb. and 25 lb. Cylinders. See Figure 2-3. MO I V4WN PMMO I NUDCT O Q NV-D/P2 Nozzle N-DCT Nozzle 002984PC 002985PC Figure 2-3 Nozzles CYLINDER BRACKETING Vertical wall mounting for the PCIA5ABC, PCIA7ABC, and PCI-25sABC, is provided by the Model MB-15 mounting bracket kit. Vertical wall mounting for the PCI-35ABC, and PCI-70ABC is provided by the Model MB-1-mounting brack- et kit. See Figure 2-4. For vertical floor mounting of the PCI-17ABC and PCI- 25sABC, an 8" unistrut type mounting bracket is available, the Model MB-U8. For vertical floor mounting of the PC[-35ABC, a 10" unistrut type mounting bracket is available, the Model MB-1.110. For vertical floor mounting of the PCI-70ABC, a 12" unistrut type mounting bracket is available, the Model MB-U12. ULEX 3437 CEx732 September 29, 1998 a 0 Figure 2-4 Mounting brackets MB-15 and MB-1 002843PC MODEL MCH - MECHANICAL CONTROL HEAD The Model MCH mechanical control head is a fully mechanical control head which can be connected to the PCI-15/17/25s/35/70 cylinder valve. This control head will support a fusible link detection system, a remote mechanical pull station (Model RPS-M), and a mechanical or electric gas shutoff valve. A miniature electric switch (Model MS-SPDT or MS-DPDT) can be ordered separately and field installed. It is equipped with a local manual control handle that allows for mechanical system actuation. Operation of the local manual control requires removing the pull pin and rotating the handle clockwise. The Model MCH control head can actuate a maximum of three (3) cylinders. See Figure 2-5. 0 0 O MLPINlnm TURN NAIIXE ro asrwSE nraE Oo0acau0 Model MCH 911.4ControlHead m ® i Figure 2-5. Mechanical Control Head. 002844PC Chapter 2 — Components Page 2-10 PRESSURE SWITCHES 1. Model PS-SPDT. The Model PS-SPDT is a water -tight (NEMA 4) electrical pressure switch which can be field mounted in the discharge piping as shown in Figure 2-22. The switch is UL Listed CCN: VOXZ) and must be installed in accordance with the instructions contained with the switch and this manual. The switch provides one set of NO/NC dry contacts. It is intend- ed for use with electric power shutoff devices (dealer sup- plied), electric gas valves, alarms, bells, lights, contactors, and other electrical devices designed to shut off or turn on upon system actuation. It is rated for 10 amps ® 125/250 VAC. 2. Model PS-SPDT XP. The Model PS-SPDT-XP is an explosion proof (NEMA 4; 7; 9) electrical pressure switch which can be field mounted in the discharge piping as shown in Figure 2-22. The switch is UL Listed (CCN: NOWT) and must be installed in accor- dance with the instructions contained with the switch and this manual The switch provides one set of NO/NC dry con- tacts. It is intended for use with electric power shutoff devices (dealer supplied), electric gas valves, alarms, bells, lights, contactors, and other electrical devices designed to shut off or turn on upon system actuation. It is rated for 15 amps Q 125/250 VAC. Figure 2-22. Pressure Switch Piping 003025PC ULEX 3437 CEx732 September 29, 1998 TIME DELAY The Model T-10 Tim Delay is required to be installed on all Pyro-Chem Vehicle Paint Spray Booth Fire Suppression Systems. The Model T-10 Time Delay is a factory pre-set mechanical time delay which retards the system discharge for a period of 10-20 seconds after actuation to allow for exhaust fan wind -down. The time delay is field mounted between the Pyro-Chem control head (Models MCH, NMCH, ECH-24, or ECH-120) and the discharge valve assembly of the agent cylinder(s) and/or pneumatic actuating cylinder(s). NNE A Figure 2-23. Time Delay 003150PC Chapter 3 — System Design Page 3-3 f. Nozzle Coverages: Protection Nozzle Protection Specifications Nozzle Nozzle Zone/Nozzle Maximum Nozzle Location within Offset** Orientation L W Ht Protection Zone Work Area NV -WA See Table 3-1 Volume 1344 cu ft Shortest side-2' max. off 0" - 6" Vertical Area 112 sq. ft center (each side) Diagonal 16.12 ft Longest side-3' max. off center (each side) Backdraft NV-P1 4' 14' 12' Volume 672 cu ft Shortest side -center 0" - 6" Vertical Plenum Area 56 sq ft Side 14 ft Longest side-3 inch off center (each side) Pant Leg NV-P1 4' 14' 12' Volume 672 cu ft Shortest side -center 0" - 6" Vertical Plenum* Area 56 sq ft Side 14 ft Longest side-3 inch off center (each side) Pit (Option 1) NV-P1 24' 4' 4' Volume 384 cu It Shortest side -center 0" - 6" Vertical Area 96 sq ft Side 24 ft Longest side -center Pit (Option 2) NV-DP2 24' 4' 4' Volume 384 cu ft Shortest side -center 2" - 8" Horizontal Area 96 sq ft Side 24 ft Height -center Under Floor NV-UF 16' 14' 4' Volume 896 cu ft Shortest side -center 0" - 6" Vertical Plenum Area 224 sq ft Side 16 ft Longest side -center Exhaust Duct NV-DP2 3' 3' 24' Volume 216 cu ft Shortest side (cross-section) 0" - 6" Horizontal for Area 9 sq ft center horizontal Side 3 ft Longest side (cross-section) ducts Round Duct 2'-11" Vertical for diameter) vertical ducts Pant leg dimensions 4" minimum x 24" maximum Nozzle offset is the maximum distance from the tip of the nozzle to the closest edge of the protection zone. ULEX 3437 CEx732 September 29, 1998 Chapter 3 - System Design Page 3-4 TABLE 3-1 Work Area - Paint Spray Booth Nozzle Protection Chart Maximum Dimensions in feet/nozzle for one (1) Model NV -WA Nozzle Maximum Nozzle Maximum Nozzle Maximum Side 1 Height Side 2 Side 1 Height Side 2 Side 1 Height Side 2 feet) feet) feet) feet) feet) feet) feet) feet) feet) 3 12 15.84 8 12 14.00 13 12 8.62 11 15.84 11 14.00 11 8.62 10 15.84 10 14.00 10 8.62 9 15.84 9 14.00 9 8.62 8 15.84 8 14.00 8 8.62 4 12 15.62 9 12 12.44 14 12 8.00 11 15.62 11 12.44 11 8.00 10 15.62 10 12.44 10 8.00 9 15.62 9 12.44 9 8.00 8 15.62 8 12.44 8 8.00 5 12 15.33 10 12 11.20 15 12 5.92 11 15.33 11 11.20 11 5.92 10 15.33 10 11.20 10 5.92 9 15.33 9 11.20 9 5.92 8 15.33 8 11.20 8 6 12 14.97 11 12 10.18 16 12 2.00 11 14.97 11 10.18 11 2.00 10 14.97 10 10.18 10 2.00 9 14.97 9 10.18 9 2.00 8 14.97 8 10.18 8 2.00 7 12 14.53 12 12 9.33 11 14.53 11 9.33 10 14.53 10 9.33 9 14.53 9 9.33 8 14.53 8 9.33 ULEX 3437 CEx732 September 29, 1998 Chapter 3 — System Desig Page 3-1 PCI-70ABC with 4 nozzles NOZZLE 002864PC Cylinder Size Nozzle Quantity Nozzle Type Piping Section Size Length Maximum Elbows Maximum PCI-70ABC 4 NV -WA Cylinder to T1 1" 20' 3 T1 to T2 1" 9' 2 T2 to Nozzle 3/4" 7' 2 Cylinder Size Nozzle Quantity Nozzle Type Piping Section Size Length Elbows Maximum Maximum PCI-70ABC 4 3 - NV -WA Cylinder to T1 1" 20' 3 and 1 of: NV-P1 (See Note 6) NV-UF NV-DP2 T1 to T2 1" 9' 2 T2 to Nozzle 314" 7' 2 ULEX 3437 CWT September 29. 1991 Chapter 3 — System Design Page 3-7 PCI-17ABC with 2 nozzles NOZZLE 002863PC Cylinder Size Nozzle Quantity Nozzle Type Piping Section Size Length Maximum Elbows Maximum PCI-17ABC 2 Any combination of Cylinder to T1 3/4" 36' 4 NV-P1 (See Note 5) NV-UF NV-DP2 T1 to Nozzle 3/4" 14' 2 NOTE: 1. These limitations apply to PCI-17ABC using two nozzles (any combination of either NV-P1, NV-UF, or NV -DP). 2. System piping must be balanced. Balanced piping is that in which the difference between the shortest actual pipe length from T1 to nozzle and the longest actual pipe length from T1 to nozzle does not exceed 10% of the longest actual pipe length from T1 to nozzle. The number and type of fittings for all T1 to nozzle sections must be equal. 3. A Main/Reserve Tee Check, Model TC-1, may be located between the cylinder and T1, and counts as two elbows in that section. 4. All systems protecting vehicle paint spray booths require a factory pre-set time delay. 5. When using an NV-P1 nozzle, the two largest discharge orifices in the nozzle body must be positioned parallel to the longest dimension of the hazard being protected. ULEX 3437 CEx732 September 29, 1998 Chapter 3 .System Design Page 3-16 Detector Placement Thermal detectors are required in all hazard areas protected by the Pyro-Chem Vehicle Paint Spray Booth Industrial Fire Suppression System if automatic system operation is required. Either mechanical or electrical thermal detectors can be used for automatic system operation. Mechanical detectors (fusible links) are used in conjunction with the Pyro-Chem Models MCH, NMCH, and EN-MCU control devices. Electrical detectors are used in conjunction with the Pyro-Chem Models ECH-24 and ECH-120 Control Heads. A temperature survey must be performed to determine the maximum ambient temperature of the hazard survey. The detectors used to protect a hazard area must be at least 70OF above the maximum ambient temperature. The minimum number of thermal detectors (either mechani- cal or electrical) required for each hazard area is one detec- tor for each twenty-five (25) pounds of agent required in that hazard area. To determine the number of detectors required in a particular hazard area, divide the total amount of agent required for that hazard area by 25 and round up. Keep in mind that at least one detector is required in every protected hazard area. Additional detectors may be used to achieve faster system response; however, do not exceed the detector limitations outlined in this manual. For detector location, evenly divide the protected hazard area into protected zones, with the number of protected zones equal to the number of detectors. Located a detector at the top center of each protected zone. ULEX 3437 CEx732 September 29, 1998 CITY OF SANFORD FIRE DEPARTMENT - q FEES FOR SERVICES PHONE # 407-302-1091 * FAX #: 407-330-5677 DATE: PERMIT #: o3-9 3 te `t BUSINESS NAME / PROJECT: ADDRESS: Z-/D(R- 144 R 4 15—— / PHONE NO.: FAX NO.: CONST. INSP. [ ] C / 0 INSP.:[ J REINSPECTION [ ] PLANS REVIEW [ ] F. A. [ ] F.S. ] HOOD [ ] PAINT BOOTH BURN PERMIT 1 TENT PERMIT ,k ] TANK PERMIT [) OTHER S TOTAL FEES: $ C ` — (PER UNIT, SEE BELOW) COMMENTS: Address / Bldg. # / Unit # 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. Square Footage Fees per Bldg. / Unit Fees must be paid to Sanford Building Department, 300 N. Park Ave., Sanford, FI. 32771 Phone # -407- 330-5656. Proof of Payment must be made to Fire Prevention division before any further services can take place. I certify that the above is true and correct and that I will comply with all applicable codes and ordinances of the City of Sanford, Florida. Sanfor Fire Prevention Division Applicant's Signature