3085 St Johns Pkwy 04-389 New construction Sanford Auto dealers Fire inspectionj0` 0 ell, SANFORD FIRE DEPARTMENT FIRE PREVENTION DIVISION 300 N. Park Ave., Sanford, FI. 32771 / P. O. Box 1788, Sanford, Fl. 32772 407 302-2520 / FAX (407) 330-5677 Pager (407) 918-0395 Plans Review Sheet Date: October 15, 2003 Business Address: 2353 JEWETT Lane Occ. Ch. Business Occupancy 38 Business Name: Sanford Auto Dealers Exchange, Ph. (407) 322-1755 FAX O Contractor: McKee Construction Ph. (407) 323-1150 FAX (407) 323-9304 Architect: Architectural Dynamics Reviewed [] Ket eW,ed Wlth C011rileri tWX Rejected [] Reviewed by: Timothy Robles, Fire Protection Inspector/plans Examiner —/;; Comment: Plans reviewed as Business Occupancy. FD reserves right to require applicable code requirements if occupancy use changes. Sprinkler System require per local city ordinance. Fire sprinkler system shall be monitored per City of Sanford local ordinance. Fire sprinkler contractor to submit design criteria for sprinkler system. 1.1 Application — New Building. 13,400 sq. ft. , Type IV- fire sprinkler protected 1.2 Mixed — N/A 1.3 Special Definitions — Meets F.F.P.C.- 6.1.11.1 (Record keeping/Business transactions). 1.40assification of Occupancy — Business F.F.P. C. 1.5 Classification of Hazard of Contents — Ordinary/6.2.2.2. 1.6 Minimum Construction — N/R 2.2 Means of Egress Components — 2.3 Capacity of Egress — One person per 100 sq ft (50 or more occupants shall comply with 44' isle ways) 2.4 Number of Exits — O.K. SANFORD FIRE DEPARTMENT FIRE PREVENTION DIVISION 300 N. Park Ave., Sanford, FI.32771 / P. O. Box 1788, Sanford, FI. 32772 ` 407 302-2520 / FAX (407) 330-5677 Pager (407) 918-0395 2.5 Arrangement of Egress — Two separate EXITS 2.6 Travel Distance — O.K., Does not exceed 129' ft 4" inches 2.7 Discharge from Exits — O.K., will field verify 2.8 Illumination of Means of Egress — O.K.; will field verify 2.9 Emergency Lighting =0k, will field verify 2.10 Marking of Means of Egress — O.K.; will field verify 2.11 Special Features —N/A 3.1 Protection of Vertical Openings — Shall be constructed as a smoke barrier with degree of compartments 3.2 Protection from Hazards — N/N 3.3 Interior Finish - Class "A "or 'T " 3.4 Detection, Alarm and Communications Systems Required fire sprinkler monitoring per City Fire Code 3.5 Extinguishing Requirements — as per NFPA 10 — Three (3) 4A rated fire extinguishers required in this building mounted at 36" from floor to bottom one (1) 2A IObc fire extinguisher required in brake room. (See blue prints) 3.6 Corridors - One -hour fare rated corridors (exception Fire Sprinkler System) 4 Special Provisions 5 Building Services 5.1 Utilities — Additional fare hydrant required per L.D.R. (250' FTfrom principle building 5.2 HVAC - shall comply with N.F.P.A. # 90 A & #90B over 2000 C.F.M. duct detectors required (blue prints show none over 1,200 c. f ) 5.3 Elevators, Escalators, Conveyors: 5.4 Rubbish Chutes, Incinerators, and Laundry Chutes — N/A Sanford City Code — Chapter 9 Fire Sprinklers: blue prints required; 2 t, SANFORD FIRE DEPARTMENT FIRE PREVENTION DIVISION 300 N. Park Ave., Sanford, FI.32771 / P. O. Box 1788, Sanford, Fl. 32772 a 407 302-2520 / FAX (407) 330-5677 Pager (407) 918-0395 Monitoring: Required by a U.L. listed Central Station for all mandated fire Sprinklered properties, per city code chapter #9 Other: NFPA 1 3-5.1 Fire Lanes — Not Required 3-6.1 Key Box —Required; will field verify, see application, and see blue prints for location 3-7.1 Bldg. Address Number Posted and Legible — Required; will field veri , see blue print for visible location 3