301 Towne Center Blvd 96-1910, 00-4126 Plans remodel Burger King;D T I. CONTRACTOR SHALL CHECK ALL CONDITIONS AND DIMENSIONS AT THE SITE BEFORE THE START OF CONSTRUCTION. THE ARCHITECT OF DESIGN SHALL BE NOTIFIED OF ERRORS AND/OR OMISSIONS PRIOR TO THE START OF WORK. 2' DRAWINGS ARE NOT TO BE SCALED. ALL WORK SHALL BE LAID OUT BY DIMENSION. ANY VARIATION IN DIMENSION FROM THE APPROVED ARCHITECTURAL PLANS AND/OR STRUCTURAL AND MECHANICAL PLANS SHALL Be CALLED TO THE ARCHITECTS ATTENTION IMMEDIATELY. ALL DISCREPANCIES SHALL BE CORRECTED BEFORE CONTRACTOR PROCEEDS WITH HIS PORTION OF THE WORK. CONTRACTOR SHALL BE HELD RESPONSIBLE FOR HIS RESPECTIVE PORTION OF THE WORK AND WILL 'BE REQUIRED TO MAKE ALL REQUIRED CORRECTIONS TO COMPLY WITH ALL DRAWINGS AT NO ADDITIONAL COST TO THE OWNER. 3• CONTRACTOR SHALL FILE ALL NECESSARY DRAWINGS AND SPECIFICATIONS WITH THE PROPER AUTHORITIES AND PAY FOR AND OBTAIN ALL PERMITS, CERTIFICATES OF APPROVAL AND OTHER LEGAL NOTICES REQUIRED FOR THIS WORK. 4° NO WORK SHALL COMMENCE UNTIL ALL NECESSARY PERMITS HAVE BEEN OBTAINED. 5. ALL WORK SHALL BE IN ACCORDANCE WITH THE GOVERNING BUILDING CODE, CODES AND REGULATIONS OF LOCAL AUTHORITIES HAVING JURISDICTION. CONTRACTOR SHALL BE RESPONSIBLE FOR THE APPROVAL OF ALL INSTALLED MATERIALS. SHOULD A DISCREPANCY OCCUR BETWEEN A SPECIFIED MATERIAL AND A CODE REQUIREMENT, THE GENERAL CONTRACTOR MUST NOTIFY THE OWNER AND ARCHITECT PRIOR TO THE COMMENCEMENT OF WORK. 6• ALL WORKMANSHIP AND MATERIALS SHALL BE GUARANTEED FOR A PERIOD OF ONE YEAR FROM THE DATE OF CERTIFICATE OF OCCUPANCY UNLESS SPECIFIED FOR A LONGER PERIOD OF TIME ON SPECIFIED ITEMS. THE CONTRACTOR SHALL Be RESPONSIBLE FOR REPLACING OR REPAIRING HIS OWN DEFECTIVE WORK, AS WELL AS PAY ALL COSTS INCIDENTAL THERETO, INCLUDING DAMAGE TO OTHER WORK, FURNISHINGS OR EQUIPMENT. 7• REMOVE ALL EXISTING WALLS, PARTITIONS, DOORS, FLOORING, CEILINGS, FIXTURES, ETC. AS SHOWN ON THE DRAWINGS OR AS REQUIRED TO INSTALL THE NEW WORK. S• PATCH AND REPAIR EXISTING CONSTRUCTION WHERE DISTURBED BY NEW WORK AND/OR 15 CALLED FOR ON THE DRAWINGS. q. WHERE EXISTING WORK IS DISTURBED BY NEW WORK. CONTRACTOR SHALL REPAIR WALLS, DOORS, THRESHOLDS, CEILING TILES, & GRID AND FLOORING TO INSURE THE PROPER INSULATION OF NEW WORK. 10. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR THE STORAGE OF ALL MATERIAL ON SITE. 11. THE GENERAL CONTRACTOR SHALL CLEAN UP AND HAUL AWAY ALL DEBRIS ON A REGULAR BASIS AND SHALL MAINTAIN THE SITE IN A CLEAN SAFE MANNER. ___ tT4,�'((Cj 7w Er=w— Rm I ""A m 71 6LL TR - - ML� 7 RK Is I I wRrp I 12. UNLESS OTHERWISE NOTED, THE GENERAL CONTRACTOR SHALL FURNISH AND INSTALL ALL MATERIALS SHOWN ON THE DRAWINGS. 13. ALL EQUIPMENT NOTED AS INSTALLED BY THE GENERAL CONTRACTOR, SHALL INCLUDE ALL UTILITY CONNECTIONS, LEVELING, AND FINAL INSTALLATION, INCLUDING START-UP. 14, DRAWINGS ARE THE PROPERTY OF THE ARCHITECT AND SHALL NOT BE COPIED OR DUPLICATED IN ANY MANNER, THEY SHALL BE USED WITH REFERENCE TO THE WORK UNDER CONSTRUCTION ONLY. MIS -USE OR THE LOAN OF THESE DRAWINGS SHALL OBLIGATE THE VIOLATOR FOR THE FULL FEE TO THE ARCHITECT. VARIATION OF OF THIS AGREEMENT SHALL BE PERMITTED BY WRITTEN CONSENT ONLY. 15. SAFETY DURING CONSTRUCTION: CONSTRUCTION SHALL BE PERFORMED IN SUCH A MANNER AS TO PROTECT WORKMEN AND THE GENERAL PUBLIC FROM INJURY AND THE ADJOINING PROPERTY FROM DAMAGE. 16, STANDARD INDUSTRY PRACTICES SHALL Be OBSERVED FOR FLASHING AND WATERPROOFING. 17. GENERAL CONTRACTOR SHALL PROVIDE STRUCTURAL SUPPORT FOR ALL ROOF MOUNTED OR SUSPENDED MECHANICAL AND FOOD SERVICE EQUIPMENT AND VERIFY HIS WORK SUCH THAT THE STRUCTURAL INTEGRITY OF THE BUILDING IS NOT LESSENED. Ig• GENERAL CONTRACTOR SHALL PROVIDE ALL NECESSARY BLOCKING AND OR PLYWOOD BACKING FOR ALL ATTACHMENTS TO WALLS AS REQUIRED. Iq. COORDINATE ALL WORK WITH BURGER KING SELECTED PLAYGROUND MANUFACTURER/INSTALLER, 20. CONTRACTOR SHALL VERIFY ALL EXISTING SITE CONDITIONS PERTINENT TO HIS WORK PRIOR TO SUBMITTING BIDS AND FABRICATION OF NEW BUILDING COMPONENTS. 21. THE CONTRACTOR SHALL BE RESPONSIBLE FOR JOB SECURITY WHILE JOB IS IN PROGRESS AND COMPLY WITH ALL O.S.H.A. STANDARDS. 22. EXISTING CONDITIONS: CONTRACTOR, BY AND THROUGH SUBMISSION OF HIS BID, AGREES THAT HE SHALL BE HELD RESPONSIBLE FOR HAVING EXAMINED THE SITE, THE LOCATION OF ALL PROPOSED WORK AND FOR HAVING SATISFIED HIMSELF FROM HIS OWN PERSONAL KNOWLEDGE AND EXPERIENCE OR PROFESSIONAL ADVISE AS TO THE CHARACTER AND LOCATION OF THE SITE. THE NATURE OF THE EXISTING CONDITIONS. THE LOCATION OF THE EXISTING UTILITIES AND ANY OTHER CONDITIONS SURROUNDING AND AFFECTING THE WORK. ANY OBSTRUCTIONS, THE NATURE OF EXISTING CONDITION, AND ALL OTHER PHISICAL CHARACTERISTICS OF THE JOB, IN ORDER THAT HE MAY INCLUDE IN THE PRICES WHICH HE BIDS ALL COSTS PRETAI NI NG TO THE WORK AND THEREBY PROVIDE FOR THE SATISFACTORY COMPLETION THEREFOR, INCLUDING THE REMOVAL, RELOCATION OR REPLACEMENT OF ANY OBJECTS OR OBSTRUCTION WHICH MAY BE ENCOUNTERED IN DOING THE PROPOSED WORK. R I i I I ` �'Ed)]) Dl,'Ea[ i ; G-el - -V ! �CJ1 TC�IWNE CENTEF-� BCJULEVARQ �A(�lFORD, FLC7F�1 a 327�'1 0"?)AV OOK�i ri gfMi F \ -w�.. -- ---•• -� ------R_ •-6l.`10._..,.. --ter OM�O ��' . JT_�� � t f• �. Y,� �, 7 l �ltffnSSl AIpMIIOi `V � . G r " a c 1 /a1 :ann l it I114GC(wal _a YA�tuTw 1 eatnx ev �� C •�• Nt 1)i Sj 4' I 1 ELL AS At (:i c. 1 LL �' I a CMAD OR •'1 �' ctIBKF t1 T t AoA AVA i oMAW DDVIII IOCP, a/ • ` tDwNa CVuNiAr i — �",^ 1 JAAtAY GMPGAOOtiO o YAAK lA DA >✓E I1 SAMDT lM _ ■ I : aIIAM+a,tM MMAND LAKE FOR ST _— 11 1[�AA 1, �OAtr�i• XIERS TI'-) l/ cmM ` O lutTTEA;O ARK LAKE MOq�OE (� c,," G 1:(fOAlS1-_,—. , yMtatVf AY i z IA ;•'1 S O 5i , � a fIN(O(v1,3< i o g ryQ 'M1 '{rj � � , jT pAIMa'AAC" ATalta r1l E3 R • 1 '�� �� a c • 1 �' B D a, (AMAI a i •' �� Ao i r t+ Koltl 29 MET un vA�Ata c, � at. r�� i nlnooA •,� / � yJ T Y / PAMM Mw, ! MSt0I1 �:' SEMtNO j, NFORO cAtATAX tM a low/ ENl(R a C NMAL � atltlr0001 UN 6a PARK N7ESOX ki, KMRI K4 � + cull Mt I ES 0TLtraain IYII�A AV YALaDM AY UNITjA VAAA �)/JA Ot MRD,M E 0`109 DIPIA,r+ lake I^ T�ENi UPSALA r a sten / t r' QO I u ,ruA, Ar fat al _may' / 't O� Pine La ' DERBY A .,.., E£J•17 „ •�� BC'' �....�t�t,a,a — PARK C BD-17 ' r ' Trout 1 i Rio( r A tr ' �EA4 take Twin Lakes to to A T PhOIA dlXUNN t O °(t 25TN mit 46A Wa ` m g _... ► .f � K 0rwwogo pE n"� 3 ■ ara A yMIA - -� erg a noAinloct � Iriana BB•16 €Lake mo B!? Q N�ti t CAM +lo uu nt l �i,4, � •r..;"yd � i�+rnu 4. "'rt� tni Dawson x A Dac„ iM1ll at0 SHEALTY AD c tAIA . tD Lake • ' 5 -. +iit'4 W090HOU W_ Hap CITY OF SANFORD TAX PARCEL # 29-19-30-503-0000-0040 IIBM, I • ! ,F-slifl,, AAumotl I 'To co VOU111F. �, ya a�� �c�adoQ cr��da�ooa� Q�� NJLa�1DL�C� � LaG3 �L�C�`�CI©Cry � DL�`L�C�dC�� tJl'/lJ r-4 o il [LOT REFLECTED LIGHTING POWER MECHANICAL PLANS & DETAILS Lz%-m1D1(;5MDLI1pm PR.Am Z� <IkG a -I l S c Q. I-^- ri ` 1_0 vA l '? 0. r✓� i t`' v -A T a v-\ v�\a �gvi5 (kh i a\ C vaT ,ir JA \'t� C W _a N z O (/) a mm z 4 1 S tLd I 6 O z Q W C 11 Ip 00 LAJO �� //"'�� ® N� t~ O x w z V i Lim ~' U - O tV�! Ld V / t V) c L O _ �p uj Q U rnncr U waU W t,- U LA ,,: o W Cz Z p W 62 U >— Z_ {� O = OL Q Hg, Q /ClN V� Z pl z JUO 0 C�z O _J Cn ~ h- o Lu ~ -Z O Of Ca5 X� d SHEET NO, T --1 o �- TO WNE CENTER BOULEVARD L 6' CONC MEDIAN 36,12 36,6 35.60 36.17 E 35.48 SOLID WHITE STRIPING uj ASPHALT PAVEMENT PAINTED 2' � STOP BAR `? SITE BENCHMARK 35.32 SOLID WHITE STRIPING SQUARE CUT IN CONCRETE WALK, ELEVATION=35.81 o CURB INLET STORM MANHOLE r TOP - 35.61 THROAT 34.78 TOP(N.RIM)-35.22 ... �� -'IA nn TYP F CURB 35.14 >l;i~P)-31.37 55.24 4 9� �Y7 33 x .,\ 29 28 26 27 2425 \ 23 9. EDGE F A ER. 1-1 - 6 3 ELEVATION = 29.1 3 3i TRA C ro C1 RE RV II RETENTII N ryg. INGRESG/R£SS, DRAINAGE &-IJTI,XfIES Mq. / 3.0 x'`a ol 'tiJry 2" X 2" WOOD OST MARKING SANITARY STUB -OUT x 32.7 32.5 TYP F 32.67 EXIST PVMT SANITARY TOP (N. F S.E. INV.( (NO LINE MARKER SITE) i ST 5' CONC SWK x32.46 i� co Co 0 _4 N 0017' 4Z. W 10' SETBACK 2' H B" RWM NOO'17'42"W 93.33' 00 1-1 R10,00' 12.00' 0 ui 45.50' T 37.10' wr .VV.VV JUA30 TS8 Elm 6"PVC mN � dP{KfJ9WAl)-gg;47 75.16, BURGER KING SANITARY "All DETACHED SIGM--1 RELEASE_ )LIGHT POLE R5.00' Rl .00' 45' 11 � 12.00' a c� LCV • M 1n.00' 0i IL JI a LLJ U a D0 a c> --20'00 a. cq �.00' BURGER KING LLUj{ R X R5,00 C 10 00 i � a ' � ';• '� r 1 ' W } Co ° 10. 0 -Tq f 0a .; ,roc U') U GAS METER •' ', ELEC. TRANS. r 45' -y -- + 41.50' 41.10' r vo n .• ..... • . ; co 20 ( R5A0 - 00 oou V' + 8, 0 LIGHT POLE M �: • " •' 1 K ` N4n'20`55 .W : 3 3 • . 0 3�.:. SHUT- VALVE R509 •,.' `►' ' 3/4" , ION METER .1rOfil :� p(I - RSAO 16.28' 12 � 0 16.19' 1 N 00'20'��r W GRATE TOP INLET TOP = 32.40 BOTTOM OF BOX = 24.32 (FULL OF DIRT & WATER) ram WNW EXIST PVMT TYP F CURB 34.34 35.02 EXI T PVM AS --BUILT SURVEY SCAL.E:. I" - 20' 3.5, .)asTltlG 0D AP A A I:CLAIN ED TER 4Af >. 0 to r x w 49.93 100 FT. WIDE FLORIDA POWER CORPORATION PAINTED EASEMENT O.R. BOOK 117, PAGE 32 10'X1' CROSSWALKS STORM MANHOLE TOP N. RIM - 35.79 N. I V. (3 "RCP) 27.18 S. INV. 30"RCP) = 27.19 FLOW --------« D 2' METAL TRAFFIC CHT SUPPORT POL 2.5' x METAL 0 ST P r� 11100 c° a UJI 1 Ln Do `n M 8"PVC -zRECLAIMED 1/2 �EOW PR -1 /2" WATE METER 1--1 /2" WET- 35.62 EXIST PVMT STORM MANHOLE TOP (N. RIM)-35.57 x 35.80 BOTTOM OF STRUCTURE - 2194 36.00 34.92 r 35.18 0 CURB INLET m THROAT - 34.40 BOTTOM OF STRUCTURE-22.57 0 20 40 SCALE: 1" 20' Q D CURVE TABLE CURVE 1 A = 67'50'13" R = 43.00' L = 50.91' CURVE 2 L = 26'49'00" R = 92.00' L = 43.06' CURVE 3 A = 89'56'47" R 13.00' L = 20.41' 0 DENOTES 2" OAK TREES TYP Q z Ln r m z 0 C� O � I a � d c z 0 10 1J / W � E31 C N o Cl O �, �- o U "o V)0�,� Q f %� i..Lw v ' U a Z f�w��Wo� QU O: LL1 W � U Q z � JJ � 0 w � ll1 Q � O V1 o i� a � L o Q �© w U >�� 0 Q5 MQ) Q d V) I I 3 N 1 U V Q 0 LL z 0 t N z Y IY ILLI 0 cz D 9 V LLI O tY CI Q Q i J LL r 0 4 Q O CL 1 l EDGE OF WA ER 1-17-96 ELEVATION =) 29.1 I TEA CT / 1 C � / RESERVED R ) RETENT19F / INGRESSZEGRESS, DRAINAGE & UTILITIES / EXIST PVMT T� YYN�" CENTER BOULEVARD SITE BENCHMARK SQUARE CUT IN CONCRETE WALK, ELEVATION=35.81 EXIST 5CONIC SWK ,K rµ 6' CONC MEDIAN ASPHALT PAVEMENT N 00'20'55" W 158.05' 4" SOLID WHITE HANDICAP P05T TRAFFIC PAINT SET BACK I D FROM E.O.P. BLUE WHEEL STOP TYPICAL - 1ID BLUE 0" TRAFFIC PAINT e' - 6" 111 12' 1 5' 1 (" RADI �-- -4" BLUE WHEN ADJACENT SPACE IS FOR HANDICAP PARKING 12 4" WHITE IF NON -HANDICAP �4.C. fA <1NGz 5TAL 5 N.T.5. 000-000 womoom Saloom womwom rrlr� 100 FT. WIDE FLORIDA POWER CORPORATION EASEMENT O.R. BOOK 117, PAGE 32 II t—r Mt WE BACK _s_T P_ _ _ METAL IGN 1 1 /2" PAINT: CHLORINATE RUBBER ALKYDE FS TT-P-115 TYPE III, FACTORY MIXED QUICK DRYING NON-i LEEDING COLOR PER LOCAL CODE. HANDICAPPED SYMBOL MUST BE BLUE IN COLOR. I 8'I ll� OF PARKING SPACE EXIST PVMT PARKING BY DISABLED PERMIT ONLY TOW AWAY ZONE &FINE TO $250.00 12" SEE DADE COUNTY PUBLIC WOl CRITERIA FOR ADDITIONAL SIG SPECIFICATIONS N.T.5. PAFHNO f)Y — MSABIPD PEAWT O"LY TON AWAY ZONE & FIFE TO #250.00 FLANGED POST PER DADE COUNTY STANDARD DETAIL R-18.1 FINISH GRADE f A I N G:; 5 1 G:; N TOTAL LAND AREA: .60 ACRES ZONING: GATEWAY PLAZA PD EXISTING LAND USE: BURGER KING RESTAURANT W/DRIVE THRU (2861 SF GROSS FLOOR AREA, WITH 80 SEATS) NEW PLAYGROUND ADDITION: 670 SF GROSS FLOOR AREA EXIST. RESTAURANT + PLAYGROUND ADDITION: 3490 SF WITH A TOTAL OF 80 SEATS (NO ADDITIONAL SEATING IS BEING ADDED WITH PLAYGROUND ADDTION) MINIMUM BUILDING SETBACKS: FRONT — 100' FT. FROM CENTER LINE OF STREET REAR — 5' FT. SIDE — 5' FT. GROSS SITE AREA: .068 AC. LESS IMPERVIOUS AREA: 0.52 AC. TOTAL OPEN AREA: 16 AC. 24% OPEN SPACE PARKING DATA: RESTAURANT REQUIRED: .04 SPACES PER SEAT (BASED ON MAX. CUSTOMER SEATING CAP.) 80 SEATS x .04 = 32 SPACE REQUIRED PARKING SPACES PROVIDED (ON SITE) 25 SPACES PARKING SPACES PROVIDED (OF SITE) 7 SPACES TOTAL PARKING PROVIDED: 32 SPACES INCLUDES 2 HANDICAP SPACES LEGAL DESCFRIFTION LOT 4, GATEWAY PLAZA SHOPPING CENTER, PER THE PLAT THEREOF AS RECORDED IN PLAT BOOK 49, PAGES 24, 25, & 26, OF THE PUBLIC RECORDS OF SEMINOL COUNTY, FLORIDA 5COFE OF UJORK ALL EXISTING SITE WORK, INCLUDING PARKING, PAVED AREAS, LANDSCAPING, CURB CUTS, ETC. TO REMAIN NEW INDOOR PLAYGROUND TO BE ADDED TO EXISTING BURGER KING RESTAURANT TO REPLACE EXISTING OUTDOOR PLAYGROUND. NO ADDITIONAL IMPERVIOUS AREA IS BEING ADDED TO SITE. EXISTING PARKING LOT TO BE SEALED AND STRIPED AFTER CONSTRUCTION OF NEW PLAYGROUND. 4 z h w r m z 3 0 0 � a 0 o � o z Q nn. � V , W a C 00 �N a � o Li �... O \ r o T w O C L. O x w O z LLv, NL c ``� O Li ~ -1 � (n UJI Q U <My ct: 44 'r- Z C�' Z 0 m(y) W "r � d ^Q c) �dUO z O LL < O j 0 CL LU O u) _ (17 rL I U) SHEET NO. �' C — NG z N 2 OP 2 0 WOOD TRUSS @ 24" O.G. 19/32" CDX PLYWOOD — W/3" X 15" SCREENED @ 6" O•C. 2x12 WOOD FASCIA TO MATCH EXISTING TOP OF GIRDER TRXJSS BUILT-UP STUCCO BAND—<, ON METAL LATH (TO MATCH EXISTING) 15# FELT ON lq/32" CDX PLYWOOD 2x FURRING @ 24" O.G. WOOD BLOCKING AS REQUIRED ,BOTTOM OF GIRDER TRUSS +14'-4 1/2" 2x WOOD BLOCKING----' 2x WOOD BLOCKING ALUM, BREAK METAL TO MATCH STOREFRONT Ix WOOD BLOCKING-- —, 51=ALANT .,.TOP OF SILL +3' -0"— 1/2" AIR SPACE, TYP. "HUGHES" WT-22 WALL TIES- @ 16" O.C. EACH WAY 4" FACE BRICK — (TO HATCH EXISTING} 15# FELT ON 19/32" CDX PLYWOOD- ---- CONT, GALV. METAL FLASHING OR 30 MIL MEMBRANE FLASHING EXT. 6" ABOVE AND 4" BELOW FIN. FLOOR.---- ,,TOP OF NEW 4 EXIST. 51-AB 01 —/ill 3/8" DIA. WEEP HOLE @ 24" O.G.--------- FINISH GRADE 12 ¢ 2x6 STUD WALL C OF 6" COLUMN I" WIDE X 14 GA. STRAP (16)METAL 16D NAILS W/ ---� OF 6" COLUMN 1---5/5" GYP. BD, CEILING ON I" X 2" WOOD FURRING @ 24" O.C. I" RIGID INSULATION BETWEEN 2x FURRING @ 24" O.C. WOOD BLOCKING AS REQUIRED STOREFRONT SYSTEM STOREFRONT SYSTEM TS Ax4x 1/4 FULLY WELDED TO VERT.TUSES, ALUM. BREAK METAL TO MATCH STOREFRONT ALL AROUND 8" TRACKS FASTENED TO TS 6x4x 1/4 HORIZONTAL TUBE W/ 1 1/2" DRIVE PINS EACH END AND REMAINING @ 6" O.C. (AND EACH SIDE OF VERT, MULLIONS) rSTOREFRONT SYSTEM OF 6" COLUMN C 2xG STUD WALL STOREFRONT SYSTEM CAULK CHAIR RAIL AND SILL TO MATCH EXISTING. DBL 2xG SILL FLASHING - "AFCO" COPPER FABRIC 502/SF OR EQUAL --HURRICANE CLIPS @ SILL-5 W/ 8-SD NAILS " --C 2x6 STUD WALL 5/61 5 " C OF 6" COLUMN 5 1/2" BATT INSULATION 5/8" GYP. WALL BOARD ON 2x6 STUDS @ 16" O.C. I"W. X 18 GA. STRAP (TOP BOTTOM) W/ 10-16D NAILS, (AT FULL HEIGHT PARTITIONS) ---------------- 2x6 P.T. STUD W/ 1/2"(P ANCHOR BOLT (4 i/2" END.) @ 32" O.C. 4" GONG. SLAB W/G"X 6" W.W,M. OVER 6 MIL VAPOR BARRIER \ _ (R�MNFW/ EXISTING DINING TOP OF SLAB Xd-- X X 4' • d a ° 12" CMU %( - FOUNDATION WALL A 8 C 23' 1 3/4" 3 3/4" 10'-8 1/2" 91-8. 2'-5 3/4 COLUMN F3 F2 � COLUMN F2 I F3 : COLUM FOUNDATION PLAN SCALE: 1/4" = 1' - 0" NORTH G" X 6" STEEL COLUMN WOOD BLOCKING 5/8" GYPSUM WALL BOARD 6"x0"X 3/8" CONCRETE FILLED STEEL COLUMN -ON 12"XI2"X 6/8" STL PLATE W/4-3/4"O X i'--4" EMB. A.B. +3" HK. ON 1 1/2" NON -SHRINK GROUT. PROVIDE 1/4"0 PRESSURE RELIEF HOLES WITHIN 6" OF TOP if BOTTOM it MIDPOINT. (TYP.) d 4: .•a d v a. 4. 8" THICKENED EDGE \—VISQUEEN VAPOR W/ (1) #5 CONT. E= BARRIER TYP. z 3" MIN. GONG, COVER z #5 @ 32" O.C. f OVER AROUND BASE PLATE ASSEMBLY IN GROUTED DELL PAINT COL. W/ 2 GOATS OF c EPDXY TAR (BELOW SLAB) - 12" CMU FOUNDATION WALL FILL SOLID W/GONG. I't NON SHRINK „ 4.q 4 v. 4 4 d - 4 4' 1 4 a q 4° 4 a d d • • Gi d 4. •a d c d a 4 fn v •v 4 a TYPICAL WALL SECTION 1 SCALE: 1 1/2" = 1' - 0'' H.S. GROUT. d it d O .4 d d• V a .q e s. a. d 4 d [] v: v d Q' a av . d 4 v v' . 1 d• - 4, 4 -1 4• •qd . 17 a a 4 a C 4 d ° 4. ..� ` 0, d 4 .14ro d a 4 REFER TO FOOTING (SEE SECTION #1 FOR ADDITIONAL NOTES) SCHEDULE FOR SIZE AND REINFORCING TYPICAL COLUMN SECTION SCALE: 1 1/2 I 011 l •EXISTING RESTAURANT - (TO REMAIN) o-- WOOD TRUSSES @ 24"- O.C. ENG. BY WOOD TRUSS MNFG., PIJOVID SHOP DRWG'5. FaR REVIEW Z D J V STRAP SCHEDULE Q HUGHES RT W/ (8) 16d UPLIFT = 7q2# []2 HUGHE5 RT W/ (16) 16d UPLIFT - 16 # 03 (2) HUGHES RT W/ (16) 16d UPLIFT - 3168# ROOF LOADS DL 20 P5F LL = 20 PSF UPLIFT = 22 P5F FOOTING SCHEDULE N0, SIZE REINF. REMARKS DEPTH WIDTH CONT, EA,WAY F1 I'-4" 4'-6" x 4'-6" 5-#5 TOP It BOTTOM F2 1'-4' 3'-6" x 3'-6" 4-#5 BOTTOM F3 I'-40 1'-a" CON[. 2-#5 BOTTOM COLUMN SCHEDULE NO. SIZE GI TS 10" x 6" x 1/2" (CONCRETE FILLED) G2 TS 6" x 6" x 3/6' (CONCRETE FILLED) A 4 COLUMN 2411II GIRDED TRU B COLUMN 24" I I / LL�� MANSARD TRUSSES, TYP. EXISTING MANSARD, TO REMAIN ROOF FRAMING PLAN SCALE: 1/4" 1' - 0" NORTH 1/4" 51DE PLATES (20" HIGH) CENTER LINE OF G.T. COLUMN AND BASE fl? BELOW- (4) 3/4"0 THRU BOLTS @ 5" O.C. TOP VIEW 3n 3" -:!<q 1/4" 51DE PLATES (20" HIGH) (4) 3/4"(P THRU BOLTS @ 5" O.C. VERT. 3/8" BOTTOM PLATE SHOP WELD ALL AROUND (TYP.)' TS 6x6x3/8 SIDE VIEW TYPICAL COLUMN COLUMN r 3 1 TRUSS CONNECTION YC 5' 4 3/4" F, V. C LUMN REMOVE EXISTING MANSARD TRUSSES UNDER PLAYGROUND ROOF. SEE SECTION A/A-5 EXISTING MANSARD, 7-TO REMAIN 2x4 CONT, HORIZ t 'X' BRIDGING NAILED TO TOP it BOTTOM CHORD OF EA. TRUSS W/ (2) 16d NAILS (TYPICAL) NEW 2" X 4" STUD WALL, BELOW (RE: A/A3) A\ [-EXISTING ROOF -� rx� EXISTING 2xG WOOD STUD BEARING WALL @ 16" O.C., BELOW NEVI ROOF TOP A/C UNIT, COORDINATE REQUIRED OPENINGS AS R Q'D 5n I/4" SIDE PLATES (20" HIGH) (4) 3/4"0 THRU BOLTS @ 5" O.G. CENTER LINE OF G.T. COLUMN AND BASE P BELOW (4) 3/4"(P THRU BOLTS @ 5" O.C. TOP VIEW 1/4" SIDE PLATES (20" HIGH)--'---, (4) 3/4"0 THRU BOLTS @ 5" O.G. VERT, 3/5" BOTTOM PLATE SHOP WELD ALL AROUND (TYP.) T510x6x I/2 COLUMN in SIDE VIEW �--� TYPICAL CORNER COL./ / � 1 TRUSS C'nNNF.f'TT(1N CL �vd �a Q i z 0 a m z 4 0 1 sp a kD 0 o z • • W �� 5 10 ON O WU? .,,... t1 Oc o c� c L O o � VI I V w A_ Z c� VI � �Q �o B2 B QU o� � Z W � ty f-- Z UQ C 5 > Q� 5 V 'u C2 \ a��Q o O z La } O I-- ^ 4-,l Ld ca °< wO w CL u, LL SCALE: 1 1/2" - 1' - 0" SCALE: 1 1/2" = 1' - 0" SHEET NO. S-1 z cs m 6- 0 5/8" GYPSUM WALL BOARD FINISH,TYP. 1' -5" EXISTING BRICK TO BE REMOVED, (F.V.) INTERIOR NEW STOREFRONT DOOR fa w O I= w z w g tTl �gY � v w _ Fy �w z x I_ EDGE OF I NEW SLAB EXISTING BRICK TO BE REMOVED AS REQUIRED FACE OF BRICK BELOW TO MATCH EXISTING SOLID SURFACE MATERIAL WINDOW SILL 5/8" GYP5UM WALL BOARD 5/8" PLYWOOD #12 TEK SCREW5 @ 16" O.C. MAX (STAGGERED) (TYPICAL) 6"X(o"X3/8" CONCRETE FILLED STEEL COLUMN (RE: COLUMN SCHEDULE, SHT. 5-1) ALUM. BREAK METAL COL. COVER (TYP.) FINISH TO MATCH STOREFRONT CAULK, TYP, FACE OF INTERIOR GYPSUM BOARD FINISH ALUMINUM/GLASS STOREFRONT SYSTEM, TO MATCH EXISTING ROWLOCK BILL V COLUMN DETAIL SCALE: 1 1/2 = I - 011 2 CORNER DETAIL SCALE: I I/2 = I 011 10 " r2:l�� 2 52" 3° NEW i.il 11 ni : n EXTERIOR 1' — 0" NEW BRICK EDGE OF EXISTING SLAB (F.V.) NEW TO EXISTING 3 CORNER DETAIL SCALE: 1 1/2 I 011 :HULK, l YP. :OWLOCK SILL _INE OF FACE BRICK, BELOW /2" AIR SPACE, TYP. =ACE OF 3/4" STUCCO, ABOVE SOLID SURFACE MATERIAL gNDOW SILL 1ATCH STOREFRONT STOREFRONT ASSEMBLY, TO MATCH XISTING 5/8" PLYWOOD 10"X/"XI/2" CONCRETE FILLED STEEL COLUMN 6/8" GYP. WALL BOARD WOOD BLOCKING AS REQUIRED, TYP. NEW BRICK ROWLOCK,TO MATCH EXISTING R-11 BATT INSULATION W/VAPOR BARRIER ON INSIDE FACE OF STUDS, TYP. 3/4" STUCCO ON METAL LATH, OVER (1) LAYER OF #I5 FELT ABOVE BRICK FACING, TO MATCH EXISTING FACING, TO MATCH EXISTING CENTER LINE OF EXISTING WOOD FRAME WALL EXISTING BRICK, TO, REMAIN WALL EXISTING PLYWOOD TO REMAIN, AS REQUIRED EXISTING DINING SLAB EXISTING PORTION OF STUCCO, AND BRICK BULKHEAD TO BE REMOVED AS NECESSARY. PATCH AND REPAIR ADJACENT FINISHES EXISTING PORTION OF STOREFRONT GLASS TO BE REMOVED AS NECESSARY. NEW DOOR TO BE INSTALLED, REWORK EXISTING STOREFRONT AS REQUIRED. 2 0- 0 10'-2 3/4" 9'-1 3/4" TYP. c 2'-9 3/4" " 2'-6 3/1 - 8 �— — — — — — — — _ CV i I �U- I � ' PROPOSED PLAYGROUND I R e co I PLAYGROUND STRUCTURE: 7 I 16'-4" MAX. HEIGHT FOR PLAY EQUIPMENT, THIS AREA � -3 00 4 i I I I I I i 1/2- MAX, I 7 Z M M L - _ z ca I J D LINE OF ROWLOCK BRICK O � S w LINE OF FACE OF BRICK I _j/ NEW ENTRY HANDLEBAR ELEMENT (RE: SHTEET A-4) 5 —' -4 I FLOOR PLAN (675 S.F.) SCALE: 1/4" = I' - 0" NORTH I PLAN NOTES O1 EXISTING, TO REMAIN Q2 REMOVE PORTION OF EXISTING STOREFRONT AND BULKHEAD FOR NEW 3'-0" X 7'-0" DOOR, TO MATCH EXISTING STOREFRONT DOORS. PATCH t REPAIR ALL ADJACENT FINISHES. O3 NEW PLAYGROUND STRUCTURE. COORDINATE ALL WORK W/ PLAYGROUND SUPPLIER/INSTALLER. O NEW STOREFRONT, TO MATCH EXISTING O STEEL COLUMNS, TYP. (RE: STRUCTURAL DRAWING) �6 ALL MASONRY, TO MATCH EXISTING O7 EXISTING WOOD COLUMNS TO REMAIN, TYP. ® LINE OF EXISTING MANSARD ROOF, ABOVE O NEW 3'-0" X 7'-0" ALUMINUM AND GLASS DOOR, PROVIDE PANIC HARDWARE ON DOOR W/ALARM. (NOTE: EXIST ONLY) 10 VERIFY PROPOSED NEW DIMENSION W/EXISTING CONDITIONS @ EXISTING PLAYGROUND PRIOR TO THE START OF CONSTRUCTION 11 NEW CERAMIC WALL TILE @ MENS AND WOMENS TOILET ROOMS. TO REPLACE EXISTING FRP PANELING. REFER TO DECOR DRAWINGS FOR TILE SPECS. 12 REPLACE EXISTING FLUSH VALVES IN TOILETS W/NEW BATTERY OPERATED FLUSH VALVES, 13 REPLACE EXISTING ENTRY DOORS. PATCH AND REPAIR ALL ADJACENT AREAS AFFECTED BY NEW WORK. 14 REPLACE EXISTING ENTRY FRONT COUNTER W/NEW SOLID SURFACE CONTER IN ACCORDANCE W/ "FLORIDA ACCESSIBILITY CODES" 15 INSTALL NEW DESERT CASE IN FRONT COUNTER, COORDINATE EXACT LOCATION W/BKC/ EQUIPMENT SUPPLIER. COORDINATE UNDERCOUNTER WORK W/ BKC, EXISTING BUILDING MEN I I WOMEN I 1 Nowe EXISTING DINING EXISTING RESTAURANT HAS 80 SEATS. EXISTING RESTAURANT W/NEW PLAYGROUND ADDITION TO MAINTAIN 80 SEATS. (DINING DOOM 72 SEATS + PLAYGROUND 8 5EAT5 - 80 5EAT5. �z 2� EXISTING KITCHEN i i i i i i i i i EXISTING i STORAGE � .AREA � i i i EXISTING EXISTING COOLER FREEZER Ocv_ ffJ �c C5" '3 d GO Ci goo OL inZ 0 W ix i� m a 0 I � o z Q • n L.J.. co V! � W c �E � - co OD Z QC U2 U) r N (L CO 0 _0 \U a O a)C L O = W O Z V/ V / L 1- WW_cV) to 0 O V <C U 09 a J Q a 1— Z W U p CL z Q J d�c\j O c=n CZ Q Q Q C� td Z 6% N Q W OL UO Z o d�L Q J a # Z O E (1� Q �Q y SHEET NO. A1 Z N m 7 15'-6" D �r T/O EXIST, LIGHT BAND WRAP FASCIA W/ BREAK METAL EXISTING _ DRIVE- THRU WINDOW EXISTING 4" DIA. STL. PIPE T D Cq i WEST ELEVATION SCALE: 114" = I' - 0" 4 SOUTH ELEVATION f Q SCALE: 1/4" - I' - 011 follull,R:�.E.�.I� ALIGN - EXISTING RESTAURANT PLAYGROUND ADDITION NEW CONT. PARAPET LIGHT BAND (TYP.) NEW STUCCO BAND, PAINT FINISH NEW ALUM. & GLASS STOREFRONT TO MATCH EXISTING STUCCO, PAINTED FINISH BRICK ROLOK COURSE (TYP.) NEW FACE BRICK (TYP.) TO MATCH EXISTING FIN. FLR. Fi-dWk9l'b9reWs-MiWWI113 URI � r 2 '-0" TOE OF PARAPET LIGHT 20=4" TOP OF ROOF 15'-6" TOP OF MAIN„ ENTRY ELEMENT -`� (ADD 3" IF BARREL TILE IS USED.) _s, 14--3" TOP OF STOREFRONT u t 9'-O" BOTf. OF SOFFIT EXISTING MANSARD 30 OU _0" TOPs7F SILL �. i i i • OF NEW PLAYGROUND ADDITION n EAST ELEVATION SCALE, 1/4 I 011 EXTERIOR FINISH SCHEDULE EXTERIOR BUILDING PAINT SPECIFICATIONS TYPE OF THOROSYSTEMSBENJAMIN PITTSBURGH SHERWIN USE PAINT THOROCOAT MOORE PAINT WILLIAMS STUCCO/ EXTERIOR LATEX BASE COLOR BRICK SEMI -GLOSS WHITE WATER SW2101 NTRY EXTERIOR LATEX N/A N/A N/A AWARD BLUE SW1812 CEMENT SEMI -GLOSS SOFFIT EXTERIOR LATEX N/A N/A N/A WHITE WATER SW2101 SEMI -GLOSS RED TILE BAND DALTILE 6"X6" GLAZED COLOR: RUBY RED. TAN GROUT ROOF MATERIALS STANDING SEAM ROOF BERRIDGE MFG. AEI-COR METAL INC. INSTALL OVER FELT UNDERLAYMENT CEE LOCK - 16" COLOR: SNAP CAP - 16" SS-3 COLOR: AND PLYWOOD SHEATHING LEAD COTE_ BRITE SILVER METAL FASCIA WRISCO INDUSTRIES, INC. INSTALL WRAPPED OVER EXISTING PRE -PAINTED ALUMINUM -- COLOR: WOOD FASCIA CAUTION YELLOW 1-800--753-1066 SOFFIT PANELING TEXTURE 1--1 1 SIDING EXISTING TO REMAIN. PAINT SHERWIN WILLIAMS #1665 "GOLD GLEAM" AT 1257. INTENSITY KEY: 1 FASCIA 2 SOFFIT 3 METAL SURFACES ELEVATION NOTES: Q EXISTING "BURGER KING" MANSARD SIGNAGE TO REMAIN.. INSTALL NEW ROUND LOGO SIGN. PAINT CABINET. -G" T,O. HANDLEBAR (SIGN TO BE DONE UNDER SEPARATE PERMIT) .EMENT 21 EXISTING RED PARAPET AND LIGHT BOXES TO REMAIN. REMOVE AS REQUIRED TO INSTALL NEW STANDING SEAM METAL ROOF. EX15TING TO REMAIN. ® EXISTING FIBERGLASS SHINGLES ON MANSARD ROOF TO BE REMOVED. EXISTING MANSARD FRAMING AND SHEATHING TO REMAIN. PATCH AND REPAIR AS REQUIRED. INSTALL NEW ENTRY ELEMENT STANDING SEAN METAL ROOF. (REFER TO EXTERIOR FINISH SCHEDULE) 3HT. A-3 FOR ILS. F6 REPLACE EXISTING 6'X6' SIGN WITH NEW 40 ROUND LOGO SIGN. ® ALL EXISTING EXTERIOR WALLS TO REMAIN AND TO BE PAINTED. REFER TO 5HT. A-2 FOR BURGER KING CORP. SPECIFICATIONS FOR COLOR. Q REPLACE ENTRY DOORS W/ NEW TO MATCH EXISTING. ® ALUMINUM BREAKMETAL, TO MATCH STOREFRONT ® PAINT EXISTING METAL FLASHING TO MATCH STANDING SEAM METAL ROOF. >TUCCO 'OND. 10 EXISTING METAL COPING, (PAINT BLUE) II ABLUE)RLLNN@ 6DSCORED -PINT AGE. LINE REFER SH. A-3 t A4 R DETAILS. 12 NEW PRE -FINISHED ALUMINUM FASCIA (YELLOW) OVER WOOD FASCIA 13 PATCH AND REPAIR ADJACENT WALL WHERE NEW ROOF STRUCTURE ENDS. FINISH TO MATCH EXISTING. 14 EXISTING D/T WINDOWS TO REMAIN, INSTALL NEW 6"XG" RED CERAMIC TILE. 16 EXISTING ENTRY ELEMENT TO BE SQUARED -UP. (RE: SHEET A4 FOR DETAILS) SHADED AREA INDICATES NEW PARAPET WALL TO MATCH EXISTING, ADDITION ADD 3/4" STUCCO AND PAINT FINISH TO MATCH. SEE SHT. A-3 FOR DETAILS. 5 ENTRY ELEMENT NEW ALUMINUM � GLASS STOREFRONT, TO MATCH EXISTING SCALE; 1/4" 1` - 0" 17 NEW ALUMINUM 4 GLASS ENTRY DOOR, TO MATCH EXISTING 1� NEW STUCCO ON METAL LATH, TO MATCH EXISTING J V N � v� m z 0 0 � I Q � w 0 z w a 0 1� 0 h V) Li � C7� � _ C ..�' % .�..rr IN' N LAJ ...... CL r 0 .,L c) �U Vw)o O o z w o Z U LLJ V) !E � �0 a V < u. Z LU U < C5 > O m �p > Q �Q W i=- CL L11 Q w X a 0W SHEET NO. A-2 zN CS' I DOUBLE WOOD TOP PLATE BUILT-UP ROOF, TO MATCH EXISTING 2" RIGID INSULATION 19/32" CDX PLYWOOD ROOF DECKING NAILED TO TRUSSES W/ 8D NAILS @ 6" O.C. THRUOUT. LAY --IN CEILING TILE 4ND GRID (RE: A/ME1) 1"WIDE X 14GA. M ETAL STRAP W/ (14) 16D NAILS (TYP.) WOOD GIRDER TRUSS 5/8" GYP. BD. CEILING ON 1 "X3" WOOD FURRING ® 24 O.C. CONT. WOOD BLOCKING AS REQUIRED / NEW 2' X 4" FRAMING / @ 24" O.C. i PORTION OF EXISTING \ MANSARD ROOF, TO BE REMOVED / 5/8" GYP. BOARD 4"X4"Xl/4 STEEL TUBE (RE: STRUCTURAL) ALUMINUM BREAKMETAL, MATCH STOREFRONT 6" X 6" STEEL COLUMN (BEYOI (RE: STRUCTUR, 5/8" GYP. BD. ON 19/32" PLYWD. NAILED TO WOOD STUDS "HUGHES" WT-22 WALL TIES @ 16" O.C. EACH WAY 5/8" GYP. BD. 4" CONC. SLAB W/ 6X6, 1.4W/1.4W W.W.M. (TYP.) ,'RE: STRUCTURAL) ........�) f- -i(^^-X x - x 1 f VISQUEEN V.B. 12" REINFORCED MASONRY (SEE FOUNDATION PLAN) GONC. FOOTING (SEE FOUNDATION PLAN) qBUILDING SECTION SCALE: 3/4" = I' - 0" LIGHT BAND BEYOND 20'--4" AFF TOP OF MANSARD ALUM, COPING, PAINT — FINISH LAY -IN CEILING & GRID 4" BATT INSULATION R-11 16'-4" CUT FASCA BOARD, AS NECESSARY STUCCO, PAINT FINISH, ON MTL. LATH ON 15# FELT 2 PCS. ALUM. FLASHING & STUCCO STOP 19/32" CDX PLYWOOD FOR ROOFING MATERIAL REFER TO SPECIFICATIONS g A-5 EXISTING STRUCTURE, TO REMAIN EXISTING STOREFRONT, TO REMAIN CONT. PARA BAND EXISTING PLYWOOD, ROOF STRU (TO REMAIN) ROOF FRAM EXIST. FACE BRICK ALUM. & G (TO BE REMOVED, RE: SHT. STOREFRON rl Al FOR LOCATION) LINE OF Pt EQUIPMENT p EXMAING CONCRETE FLOOR, TO RE: FLOOF RE FACE BRICP 1/2" P.M. FILLER FIN. FLR. STANDING SEAM METAL ROOF WOOD TRUSSES @ 24" O.C. ENGINEERED 8Y WOOD TRUSS MANUF. 24"WOOD GIRDER TRUSS ENGINEERED BY WOOD MANUF. METAL FASCIA ON 2X12 WOOD FASCIA PAINTED CONT. 2X4 WOOD — LEDGER 5/8" CDX PLYWOOD PAINTED DOUBLE WOOD PLATE, " GIRDER TUSS B MANSARD TRUSS SECTION SCALE: 3/4" = I' - 0" c SECTION SCALE: 314" = I' - 0" CT mc mo Q+ < Lo 0-� Q 1 O CVco co,� aL �o Lw CQ CL LL V) _ 0 Im Im 0 a a 0 i 0 -H fl o � W LLJ 00 r.�... G O "T \U a x V)0�C= s.,. O z ,^ V w 4� 0 LLJ /0 L_ o S c� V v � aoi a � W q L OH' a I,n t,. Q Z O C ~ �< W W QL lJ c >Q o Z LL �LZQ W w Z 0 V 0 SHEET NO, A-3 z T w o- Q TD 8"XIG GA, PROVIDE STUCCO DRIP TRACK CONN. TYP. AT BOTH 51DES I��,i� DOD BELTS 7/8" EMBOSSED TEXTURED @ 24" O.C. STAG, STUCCO W/ #15 FELT LAYER OVER MTL. LATH NAILED @ 8" O.0 SEE STUCCO DIET. ON SHT, A-5 VARIES I - LAYER' 5/8" PGGLYWOOD JOI NTSETTED YPP. CEE 8"XI6 GA. @ 24" O.C, TYP. LINE OF EXIST, WALL TOP OF PYLOP +18'-6" A.F. r -#12 TEKS @ 12" O.C. (TYP.) 7CEE 8" X 16 GA. MTL. STUD t- TD 8"XI6 GA. #12 TEKS @ 12"O.C. (EA. 51DE) r- 11" ELA5TOMERIC SEALANT WATERPROOFING ON HORZ. EXPOSED STUCCO nl-t SURFACES (SIKA OR EQ.) Nv �... I -LAYER 5/6" PLYWOOD STAGGERED JOINTS (ALL AROUND) 7/8" EMBOSSED TEXTURED STUCCO W/#15 FELT LAYER OVER MTL. LATH NAILED @ 8" O.0 I CEE 8"XI6 GA. + TD 8"XI(o GA. is HANDLE54f;:,) 5ECTION ! SCALE: 1 1/2"-1'-0" FULLY ADHERED• EPOM WALL COVERING TOP OF PARAPET ,Z41 22 GA. GALV. STEEL CONT. CLIP NAILED AT 12" O.G. STUCCO BAND W/ METAL LATH OVER 1-1/2" THICK RIGID INSUL. BOARD TO MATCH EXISTING #12 TEKS @ 12" O.C. TD4 X IG GA. CEE 4XI6 GA. @ 1G" O.C. METAL LATH W/ONE LAYER/#15 FELT ON 3/4" STUCCO OVER 19/32" PLYWD. (2) #12 TEKS Tp 4X1(o GA. W/ 1 /4' 4)X 2" LG HD SCREWS @ 81f O.C. REFER TO ADJACENT DETAILS FOR INTERNAL STRUCTURE 24 GA, PREFINISHED STEEL COPING CAP PER SPECIFICATIONS SLOPE SLOPE F;�oOf= A i SCALE: 3"=I'-0" �u : MEMBRANE TAP MASTIC 24 GA. (PAINTED- S.S. CONT.) MTL STUCCO TOP COUNTER FLASHING FASTENED @ 8" O.C. FIBER CANT SET IN BITUMEN CONT. BASE FLASHING SET IN MASTIC @ BASE AND WALL TAPERED PERLITE BOARD 8" GEE 16 GA MTL. STUD Iln TOP OF PYLON + . . rr-- --� TOP OF PARAPET CEE 4"XI6 GA. DIAG. I BRACE @ 16" O.C. I W/ (4) #12 E.E. I TOP OF TRU55 1 t I I t 24 GA. PREFINISHED STEEL 1 COPING CAP PER SPECS. 1 CEE 4"XI6 GA, HORIZ. 1 BRACING @ 16" O.C. 1 TOP NAIL FLASHINGS AT 4" O.C. FASTEN @ 16" D.C. WITH GROMMETTED FASTENERS MODIFIED BITUMEN FLASHING - SOLID MOPPED IN ASPHALT MODIFIED BITUMEN FLASHING BASE SHEET - SOLID MOPPED IN ASPHALT ON 19/32" CDX PLYWD. TYPE IV FELT NAILED TO WALL AT W D.C. IN BOTH DIRECTIONS USING I" GAP NAILS ((MOP OVER CAP SHEET ON SURFAGE OF CANT) MODIFIED BITUMEN FLASHING BASE SHEET NAILED AT 4" O.C. ON TOP AND SOLID MOPPED c IN ASPHALT MODIFIED BITUMEN FLASHING NAILED AT 4" O.C. ON TOP AND S ID MOPPED II�„ASPHALTfl 710N DETAIL NEW BUILT-UP ROOFING OVER PREVIOUS ANGLED ROOF. +i 171 NEW HANDLEBAR _" -- 5HADED AREA INDICATES NEW ELEMENT. SEE �- PARAPET TO MATCH EXISTING. DETAILS THIS ���' �O �L� 5EE THIS SHEET FOR DETAILS. SHEET. AREA OF NEW WORK ONLY SCALE: 3B A-4 Ii" j� TOP OF HANDLEBAR { �...�A.F.F. oz I EXTERIOR PYLON FINISH u REF. TO SHT. A-4 FOR ADDITIONAL INFORMATION ' ` NEW BUILT-UP ROOFING. SEE SHEET A-3 FOR SPECS. NEW 1q/32" CDX PLYWD (2) CEE 8"XI6 GA. @ END. RE.: SEC. , 3/A-3 / lq/32" CDX PLYWD.ROOF DECKING LINE OF EXISTING BEYOND. HIGH PARAPET DECKING SCREWED W/ #12 TEK5 @ 6" O.C. T.D. PARAPET LT. BAND (EXIST.),,, / CEE 8"X16 GA. HORIZ. SCREWED TO VERT. / H/ (5) #12STEKD5 AND W/ (6) #12 WOOD SCREWS TO EX. ROOF TRUSSES, / (SEE SECTION). NEW GEE 8"XI60A. / EXISTING WOOD VERT. FRAMING TRUSSES AND @16" O.G, / DECKING TO REMAIN (TYP.). `- L 6"X6"XI6 GA. X 0-4" W/ 5) #12 TEKS INTO COLD FORM STUD AND �6� #12 WOOD SCREW5 CUT EXISTING N 0 WOOD. TRUSSES AND REMOVE AS REQUIRED TO CLEAR FOR NEW COLD FORM STUD ASSEMBLY. g�44NDLE5 SCALE: 3/4"=1'-0" NOTE: NAILING PATTERN FOR PLYWOOD SHEATHING TO METAL STUDS IS: #10 TEK SCREWS @ 8" O.C. NEW PARAPET WALL TO MATCH EXISTING -` (BEYOND).------� 4fR SECTION CEE 8"XI6 GA. @ 24" O.C. CONN. TO TRACK TD 8 AT EA. END W/ (2) # 12 0 TEK SCREWS, N GEE 8"X16 GA. W/ (2) 1/4"(P TAPCONS INTO CONC. PAD. EXISTING PREFAB, ND. TRUSS (TYP.) (COORDINATE W/ EXISTING DBL. CORNER WOOD GIRDER TRUSS VERT. STUDS) 1/4"(P X 1 1/2" LAG BOLTS OR SCREWS + WASHERS @ 8" O.C.- - 7/8" EMBOSSED TEXTURED STUCCO - 5/8" PLYWOOD SHEATHING - 4" GONG. PAD W/ (2) #4's VERT. DOWEL EPDXIED INTO CONC. SIDEWALK 2" CLR. T.O. -SLAB (EXIST. ).L EL. +0 -0 A.F.F. _ F 4' --10 1/8" t 8'-511t VERIFi - - - V-6 7/8"t i HANpLE5/4tq< SECTION .� SCALE! 3/4"= I' -0" NEW GEE 8X16GA. TWO (�2) STUDS CEE 8' XI6 GA. + VERT. FRAMING TD WX16 GA. EXTERIOR PYLON FIN @16 O.C.-�--- 1 4 \ %^TO DETAIL5. I (jI rl t �r� I r r I r r r r I �.r.�...✓. ^ r r r I I 1 1 I I I 1 I I I I ! I ! 1 I I I 1 I I (I I I II \ I I I \ 1 \ ! , I I i I � 1 \ I I I \\ f I I I I \ I I \ I I \ 1 >I i I I I I ! INDICATES BUILDING EXTERIOR OUTLINE I i (6) 1/4"0 X 1 1/2" LAG BOLTS OR SCREWS + I"(P WASHERS OR SCREW 5A ! (2 @ 3" O.C. FROM - - CORNER) CONNECTING -` HORIZ. CEE 8" TO EX. TOP WOODEN PLATE. I EXTERIOR WOOD STUD I WALL. REMOVE STUCCO DOWN TO I PLYWOOD. ' I L. CEE 8X16 GA. @ I 24" O,C. CONN. TO I ESCREW52) ##12ATEKCK TD e"XI6 GA. TRACK CONN. TO WOOD W/ 1 1/4110 LAG BOLTS + I "<P WASHERS @ 24" I O.C. STAGGERED 'TOP OF HANDLEBAR fj + 3 L 4X4X16 GA. X 0-4" W/ (4) #12 TEKS EA. LEG. RELOCATED EXISTING ELECT. J-BOX FOR LOGO SIGN TO NEW LOCATION ON HANDLEBAR. COORDINATE WITH SIGN COMPANY ON EXACT LOCATION. TWO (12) STUDS GEE 8' (6 GA. + TD 8"46 GA. +q' -0" TO A.F.F. L 4X4X16GA.X0'-4" W/ (4) #12 TEKS EA. LEG. 6 (5)I I' #12 TEKS W(TO HORIZ. STEEL STUD CONN.) AND (5) 1/4"0 + I 1/2" LONG LAG BOLTS (OR WOOD SCREWS) TO VERT. STUD WALL (@ CORNER) NOTE: BOLTING 15 THRU THE EXT. PLYWOOD CLADDING). 4" GONG, PAD W/ #4's DOWEL EPDXIED INTO GONG. SIDEWALK @ 12" O.C. 4 244 HORIZ. (LONG WAY). 2" CLR. N15H FLOOR _. +0'-0 A.F.F. NOTE: 1. NEW HANDLEBAR HAS BEEN DESIGNED FOR 100 MPH WIND SPEED IN ACCORDANCE WITH THE SBC Igg7 EDITION, 1606. C, OL �. ZUcz CTffJ boo �.� Q3 r- _: QL�' _t !X Cfl�� CLL4L, H w w 2 Q > W Ld 3 N C4 QI � g a m In L O � • 8 W 0) 0)o 6 'C- c c - Z/T W \� �U) - U) 2 r N p0p Q O 0 C t O w z V / NN f^ I.L.. V 1 v �� z F- ` t� �8`°� to rnu O ms VQ <0 u� Q W L.1 i-- Z Q Lu Q (15 W � O � CL =ON o Lu !j'] Lu � ��" Io N Z OL � U � (a L1 LL � M p� j W �- LL �Q r Z Q caQ �3 oQ w� U) �444NDLE54R SECTION SCALE: 3/4"=I'-0" HANDLEBAR SECTION SCALE: 3/4" = I'-0" - - SHEET NO. 0 //0- Ut:l-lt:N I I tK UN SELF FURRING METAL LATH PAINTED BLUE TYP. SCORED CEMENT PLASTER ELEVATION SCALE: NONE NOT USED SCALE: SCALE: NORTH TannV 13T ANT PLY NG STANDING SEAM METAL LINE OF WALL BELOW 4" ROOF DRAIN. EXTEND LEADER TNRU ROOF TO EX15TINQ ROOF. PROVIDE SPLASH BLOCK. EX15TING ROOF ROOF ACCESS LADDER (RE: I/A5) STANDING SEAM METAL (RE: SHT, A2) 7/8" CEMENT PLASTER ON SELF FURRING METAL LATH SCORED DIAGONALLY. PAINTED BLUE 1/21' WIDE X 1/2" DEEP ROUTE CUT "V"-GROOVE 2" FROM FA(-" CORNER (TYP) TO '11NATE FIELD OF ;ONA L SCORING SCORED CEMENT PLASTER JOINT SCALE: NONE 1/2" WIDE X 1/2" DEEP ROUTER CUT "V"-GROOVE (TYP, ) H-MENT PLASTER ON `URRING METAL LATH :D BLUE: 2' -0" 1/2:12 TAPERED PERLITE EDGE STRIP SUMP - SOLID MOPPED IN ASPHALT 6" 30" X 30' LEAD FLASHING S IN MODIFIED BITUMEN CEMEI AND PRIMED FIELD TAPER EDGE FOR �/ SMOOTH TRANSITION LIP REFER TO STD. ROOFING SE TION UNDER DECK AND BASE FLASHING DETAIL CLAMP FOR ADDITIONAL INFORMATIO :7 ROOF DRAIN DETAIL SCALE: SCALE: 3"-1'-0'" 2'-0" MIN. TO ..- �p INSIDE OF PARAPET WALL CAST I RON STRAINER CAST IRON CLAMPING RING CAST IRON DRAIN BOWL METAL RAILINGS PARAPET BEYOND MIN 2", MAX, 4" ABOVE—\= LOW ROOF DRAIN FOR OVERFLOW. SLOPE 1/4" PER FT. (1 2X WOOD LEDGERS 4" BATT INSULATION R-II 24" WOOD GIRDER,- (RE: STRUCTURAL) 5/8" GYP. BD. STEEL COLUMN, BEYOND 2" X 4" STUD WALL (RE: A/A3) SELF FURRING METAL LATH SCORED DIAGONALLY. PAINTED BLUE SCORED CEMENT PLASTER CORNER DETAIL SCALE: NONE AIL FLASHING @ 4" D.C. MODIFIED BITUMEN FLASHING PER 'ICATIONS - SEAL LAPS CORNERS DIFIED BITUMEN CEMENT FABRIC ED BITUMEN FR CAP SHEET PECIFICATIONS - MOPPED IN LT ED BITUMEN BASE SHEET PER 'ICATION5 - MOPPED IN ASPHALT TO STANDARD ROOFING SECTION STD. BASE FLASHING CONFIGURATION SCALE: SCALE: 3"=1'-0" SMOOTH EDGES (TYP.) f Ez x= +�f Y 4 t� 7"x4"x3/8"x4" LONG U'D p 't BOLTED TO WALL W/ O U -- z tfJ 3 1/2" LONG 5/8" '/ O DIA, LAG SCREWS O LL o --- METAL LANDING _ tD �X Cl LL STANDING SEAM METAL MANSARD ROOF (BEYOND) +I(o'-4" ° 3/4"x2' -O" STL. RODS @ 12" O,G. VERT, SECURED TO 2"xl/4" STL. RAILS (STRINGER) STUCCO, PAINT FINISH, ON , MTL. LATH ON 15# FELT, TO J MATCH EXISTING 2 PC5, ALUM. FLASHING t STUCCO STOP 19/32" CDX PLYWOOD / --- FOR ROOFING MATERIAL - REFER TO SPECIFICATIONS l 4"x4"xl/4"x3" (I PER RAIL) W/ q/16" BOLT 1 A-5 1 SECTION Cs? ROOF ACCESS SCALE: 3/4" - I' - 0" A/C UNIT GASKET - SUPPLIED W/CURB A/C UNIT RAIL SECURE A/C UNIT TO CURB WITH (4) 3/5" THRU BOLTS EACH 511DE AND AT EACH CORNER OF EQUIPMENT AND MID --LENGTH OF LONG SIDE. Ix WOOD NAILER SUPPLIED W/CURB �---COUNTER FLASHING CANT STRIP ROOFING MATERIAL UNIT CURB TYP . A SCALE: NONE 2" x4" P.T. WOOD @ 24" O.C. CLAMP W/ HID, SC CONDENSATE PIPE ADDITIONAL LAYS SURFACE CAP SH" FROM ROOF SYST INSULATION AS NC ON ROOF PLAN STRUCTURAL SUB- I 1 -1 . , - DECK INSULATION PLYWOOD DECKING SECURE A/C CURB TO ROOF DECK W/1/2" LAG BOLTS 1 1/2" MIN. EMB,) @ 24" O.C. LL AROUND, (2) 2x8 PER ROOF PLAN TING DETAIL CONDENSATE PIPE DETAIL SCALE: NONE in z 0 rn m 0 CD M o� V/ W 00 C N LLJ .�... o U VU s o L.LJ V I $ is U O uj \./ <0 Ld ; W Z U Q Cj > — CL O CV v p Q � � z o > p� � a- w LLH- F- LL °o #-4-1 Q a Q w SHEET NO. A— Cs' 0 6.. REFLECT SCALE: 1/4" a I' 120/208V NEW PANEL P 100 M.C.B, 3PH, 4W CKT.# DESCRIPTION C\BTRI LOAD HIRE COND. REMARKS 113,5 A/C UNIT 3P-50 12000 3 #8-3/4"C. 2 PLAYGROUND LIGHT] IP-20 1000 #12-1/2"C 4 ROOF RECEPTACLE IP-20 600 #12-1/2"C 6 VIRTUAL FUN CENTS IP-20 1600 #12-1/2"C 8-12 SPARE IP-20 1000 #12-1/2"C 13-18 SPACE IP-20 300 #12-1/2"C TOTAL: 16500 (46A) ELECTRICAL NQTE: AS AN ALTERNATE OPTION, ELECTRICIAN TO REVIEW WITH LOCAL POWER COMPANY EXISTING LOADS ON EXISTING MAIN PANEL 'M' TO DETERMINE IF TI-IERE IS ANY SPARE CAPACITY IN MAIN PANEL 'M' SUFFICIENT TO TAKE NEW LOADS (46A) FOR NEW PLAYGROUND ADDITION. ELECTRICIAN TO ADVISE BKC CONSTRUCTION MANAGER/ARCHITECT/ELECTRICAL ENGINEER ON ABOVE, HCM EXISTING M.C.B,-600 A,(SEE PNL.GEN. SQD - HCM3686-6M-CU PANEL M NOTE A.) (NO CHANGE) VOLTS-120/208 30 4W 60 HZ. CCT NO. DESCRIPTION VOLTS PHASE POLE FRAME TRIP KVA AMPS 1 A/C UNIT #1 (PACKAGE UNIT ON ROOF) 208 3 3 100 50 * 10.6 29.4 2 A/C UNIT #2 (PACKAGE UNIT ON ROOF) 208 3 3 100 50 * 10.6 29.4 3 A/C UNIT .#3 (PACKAGE UNIT ON ROOF) 208 3 3 100 60 * 12.6 35.1 4 A/C UNIT #4 (PACKAGE UNIT ON ROOF) 208 3 3 100 60* 12.6 35.1 5 PANEL A 120/208 3 3 225 150 36 100 6 PANEL B 120/208 3 3 225 225 64 177 7 PANEL C 120/208 3 3 225 200 45 126 8 PANEL D 120/208 3 3 125 125 32 84 9 SPACE 120/208 3 3 100 -- — --- 10 1 SPACE 120/208 3 3 100 — -- — * ADJUST AS REQ'D. IF ELEC. TOTAL 616 AMPS HEATING UNITS ARE USED, LESS DEMAND COOKING LOAD - 49 AMPS SERVICE 4-#350 kcmil (CU) IN EACH OF 2- 3" CONDUITS 567 AMPS A-31,33 A-35,37 ROOF FIN. FLR. "P(9 o& F WP �F WP (';(��`j_� r r tip. `i ��`•y'�'C� y 1 , i P-6 1 1 t i� I I I i 1 1 1 i A/C UNIT I I P-4 1 1 I WP/GF i I i I t i i Li 3-#12 & 1-#12 GND. IN 1/2" C. B POWER PLAN SCALE 1/4 I 0 3--#8 & 1-#10 GND. IN 1" C. 4-2& 11 GN IN 1 1 /2"' C. SEE WIRING I MASTER DIAGRAM ON RELAY SEE RISER SHT. E-4 PANEL I NOTE #6 C I CONTROL I EXISTING PANEL F1 , PANEL I ANEL A L D I J L M-5 LOCATED IN KITCHEN EQUIPMENT 4-#1/0 & 1-#6 MORS. OFFICE MOUNTED PANEL- ONDD. IN 2"C. SEE SHT. E-2. CONTRACTOR CONNECT FEEDER, CONTROL WIRING TO MASTER CONTROL PANEL P1G�1 P`G�ti P1G,�^� P1G�>k C C C C 3 5o 3 50 3 so 360 �`�, F F F F I- r-I WP �WP WP WP M-1 _M-2—� M-3M EXISTING PANEL B TIME CLOCK FOR SPRINKLER SYSTEM (OPTIONAL) 4#1/0 & 1#6 GND. IN 2" C. TC EXISTING PANEL C M- GROUND BUS ---f- EXISTING PANEL "M" STRAP -- 3-#6 & 1-#10 GND. IN 1" COND. IN5TALL NEW PANEL 'P' ADJACENT TO PANEL 'M' GENERAL ELECTRIC THYRITE ARRESTOR 3-POLE, 4-WIRE 1 1 /2"C 91_156CC003 f_NEW7 OR PANEL CT WESTINGHOUSE 'P' WP CAN VALVE TYPE ARRESTOR S 634,A.217.AO1 T (INDOOR W W.P. BOX & CO ER) OR SQUARE D J-9200-9A L� 225' BARE CU -� - 2/p GROUND SEE RISER NOTE #7) . BOND TO METALLIC COLD WATER PIPE SEE NOTE 6 1 #6 ISOLATED GNND.IN 1 /2"C. EXISTING ELECTRICAL RISER DIAGRAM N.T.S. 4#3/0&1#6 GND, IN 2 1 /2 C. ABOVE GROUND 3/4"C �2(0 FOR GROUND. EN.E.C.250-81(C) BOND TO REBARS. LOCATE PER POWER CO. REQUIREMENTS PROVIDE MAIN BREAKER SHUNT TRIP BREAK GLASS SWITCH (ASCO OR EQUAL) - WHEN REQUIRED BY LOCAL CODE- MOUNT W.P. SWITCH FLUSH IN OUTSIDE WALL AT METER LOCATION, #6 COPPER SOLID (GROUND) 4#350 kcmil IN EACH OF .2 -- 3" C. TERMINATE RACEWAYS AND CONDUCTORS AS DIRECTED BY POWER CO. �4 #3 - 1 1/2" C. TO POWER COMPANY TRANSFORMER COORDINATE SERVICE INCREASE. DIFFUSER SCHEDULE SYMB, SIZE TYPE DUCT SIZE METAL-AIRE MODEL # FINISH BOOT SIZE OPEN'G. SIZE I 24X24 SUPPLY 4 WAY 12"(P 5000-MG-54 WHITE 12" T-BAR 2 24X24 RETURN 18" CC-5-TB WHITE 22X22 T--BAR A/C SCHEDULE A/C UNIT NUMBER I TYPE OF HEAT ELECTRIC QUANTITY REQUIRED I AREA SERVED PLAYGROUND MANUFACTURER CARRIER MODEL NUMBER 50HJ007 TOTAL COOLING CAPACITY BTU/HR 66,000/45,Boo TOTAL SEN51BLE CAPACITY BTU/HR 800/670 CFM SUPPLY AIR 2400 CFM OUTDOOR AIR 400 EXTERNAL STATIC PRESSURE 'N.G.' 10" FAN H.P. 2.4 E.E.R. 11.0 AMBIENT AIR TEMP D.B. 950 TOTAL HEATING REQ'D. KW (ELECTRIC) 15KW UNIT WEIGHT LBS. 520 ELECTRIC SERVICE AVAILABLE 208-240/3/60 MINIMUM CIRCUIT AMPS 27.5 MAXIMUM FUSE AMPS 35 1. 4 YEAR EXTENDED WARRANTY ON COMPRESSORS 2. MANUAL OUTSIDE AIR HOODS 3, PROVIDE A SMOKE DETECTOR IN THE SUPPLY AIR BEFORE DUCT BRANCHES, 4, VARISLIDE BAROMETRIC ECONOMIZER (OPTIONAL) I zU� Q) �x � Q a � � z o D } rr m 3 O h Q I O W 0 ti 6 az V / W 0)a, o 1— �� C Q N Wc rrrr Q.. O r O �o �. o Loo o z I..L.. V / V 0 f= ui 0 (AD � �o 0 V Q U m, c� �) M d�Wo 4 tP - W Q U CL Q ZJ� < SCUM Q �0 3 � — Q LL > ,O©L a (1(� Q O Q w li Lu it_1 a z u) !Y SHEET NO. lYU�. E 1 z � CITY OF &�JIFORD MAL INSPECTION REQUIREO SANFORD BUILDING DEPT. THESE PLANS ARE REVIEWED AND CONDITIONALLY ACCEPTED FOR PFRmrr. A PERMIT ISSUED SHALL BE CONSTRUED TO BE A LICENSE TO P ' Rc THE WORK AND NOT AS AUTHORI-I-y -)CEED WITH TO VIOLATE, CANCEL. ALTER, OR SET ASIDE ANY OF THE PROVISIONS OF THE TECHNICAL Cr-)C)F-� NOR SHALL ISSUANCE OF A PERMIT PPEVErqq- , ' DEPT FROP4 ?'HEREAFTER —E BUILDING -REAFTER REQUIRING A CORREC- TION OF ERRORS ON THE PLANS, CONSTRUCTION QF? 9THER VIOLATIONS OF THE CODF-s - . ) CiiY of Sanford Model Codes in effect: Standar(l Building Code 1997 ed. '-'tandard Plumbing "'ode 1997 ed. tc andard tvler,'11FArlicEll C'Ode 1997 ed. Natfon€tl Flertrioai Code 1996 ed. So-' ClItY Coda AMENOMENT8 FL, Accessibility 100des 1997 FL Ltnergy code 1997 T r L Mu.Er-,-5T I'Vlf,-.ET FLO 1,10 'A E CODEEN OF�ICL u�1�� 4 5 d 1 S - ✓� t t 4 ISSUE I SHEET DATE I N0. E�W�L 14H[MmPiF�HHNN FOR SITE DWGS., SEE SHTS. C-1 THRU C-12. ----------- f I I ��_T OR ullillillcm: "Till III I S-1 FOUNDATION PLAN S-2 ROOF FRAMING PLAN S-3 FOUNDATION &ROOF FRAMING DETAILS S-4 MISCELLANEOUS STRUCTURAL INFORMATION A —1 FLOOR PLAN & MISC. DETAILS A-2 EXTERIOR ELEVATIONS A — 3 BLDG. CROSS —SECT. & RESTRM . ELEVATIONS A-4 REFLECTED CEILING PLAN A — 5 ROOF PLAN AND DETAILS A-6 EXTERIOR WALL SECTIONS A-7 REAR & RESTRM, EXTERIOR WALL SECTIONS A — 8 DOOR AND FINISH SCHEDULES A-9 SEATING LAYOUT & INTERIOR ELEVATIONS A-10 DIRECTORY OF MANUFACTURERS & SUPPLIERS A —11 OPTIONAL FRONT BAY ADDITION r V . d -1R' itd ... •r' t. Lam.{ � ti: S�e''�i: at r a'`: S: � f'' i i. 8 t A, -3r %: t ly♦ y ,. x•..ss _ %' . _ ,d' . :-."` .. �,>E :'h r�.i i � ,,'t�t:1,r.�1.LL � i; �i�!�{,a, _ ,-{�, � # ;�- [��A}t � � . 1 ' e �•, "� r ,,. t�.`, Z.px..i, '�......' � to _< . J� „� tea [.1�N'�,. ��t� iySo }77}..��Q�•A„A� 4�qs }��. �-.�x5 `,� �.�.)j �i�`_ ) �Ji 4t� rl y�. �p>�.. � x '�+�< • 9'} } .�.•�+.T �Y't111.;'^ e'R}x Vd•r°n 'Y 1 t•. ,t`JSTJ` C.btt �,Y f. ,S '1'e:ex;-` f yir* {t f 1sk `�' z *ti r_ *�; ,,,<... ,, ;— �, .�4=9 +i f� ;''y i _• ;• %i # •�_'�'tr,•,� r," ;S, ,i , t . <s, .,{"., N•. .a,}..�;4..tt. S ^; � - . - '' -d ,n,'r— .„,, .,� §r. `'t 4• < `,'yw;a,..y.�,e-•,e�-."'s .'f`' - ,� N�.� } ire. �• t- _5koq11 hw m to Y WFx 0 � is X 0. 40 4 �AA it 7' UT111TY GGRNECTION EE+E / _? 57 r d v!�' ar r , y L F. I u i A Elam Effinismm mam V 1 1 .�.� [wimNS ISSUE DATE SHEET NO. 7 7 L YW PLYWOOD A.I.C. -ALT. INTERRUPTING CAPACITY I.U. -INTERIOR DESIGN INSUL. -INSULATION A.B. -ANCHOR BOLT I A.F.F. -ABOVE FINISHED FLOOR L.L.H. -LONG LEG HORIZONTAL © r� U LI TEXTURE ALT. -ALTERNATE ALUM. -ALUMINUM AUX. -AUXILIARY L.L.V. -LONG LEG VERTICAL L.P. -LOW POINT LAV. -LAVATORY B BD . -BOTTOM OF . -BOARD LOC.-LOCATE,4 s LG. -LONG EQ —1 EQUIPMENT LAYOUT PLAN AND SCHEDULE I GYPSUM BOARD BLK'G. -BLOCKING BOT. , BOTT. -BOTTOM BRZ . -BRONZE MAS. -MASONRY MAX. N. -MINIMUMM MOUNTED MTL . -METAL EQ — 2 EXHAUST HOOD & FIRE PROTECTION SYSTEM G —1 GAYLORD BROILER VENTILATOR F I N I SH v -CENTER LINE UIT ELG. . -CEDING N.I .C. -NOT IN CONTRACT G — 2 GAYLORD 6 BANK FRYER VENTILATOR WOOD COL. -COLUMN CONC. -CONCRETE CONN. -CONNECTION O.C. -91 CENTER O.D . -OUTSIDE DIMENSION O.H. -OVERHANG U DW[r—`� ROUGH CONT. -CONTINUOUS CONTR . -CONTRACTOR 0/0 -OUT TO OUT WOOD CTR. -CENTER C•W• -COLD WATER 0 -PHASE, DIAMETER d R_ -PLATE AC-1 HVAC FLOOR PLAN & SCHEDULES METAL GLASS BRICK -DIAMETER, PHASE DIA. -DIAMETER, DIAGRAM DBL. -DOUBLE D/T -DRIVE-THRU DWG. -DRAWING E.F. -EXHAUST FAN ELECT. -ELECTRIC ) EO.-EQUALTI°N EQUIP. -EQUIPMENT E.W. -EACH WAY EXT. -EXTERIOR PLYWD . ,PLWD . -PLYWOOD P.O.S. -POINT OF SALE y PREFAB. -PREFABRICATED P.S.F.-POUNDS PER 50. FOOT P.S.I. -PODS PER SO. INCH P.T. -PRESSURE TREATED PTN. -PARTITION P.V.C. -POLYVINYL CHLORIDE R.D. -ROOF DRAIN REINFT -REINFORCING REQ'D. -REQUIRED R.W.L. -RAIN WATER LEADER C —1 A HVAC FLOOR PLAN & SCHEDULES ( ALT .� AC-2 MISC. HVAC DETAILS P —1 SANITARY AND WASTE PLANS AND RISERS �• •° CONCRETE ' -FLOOR CLEAN OUT F.D.° -FLOOR DRAIN F.E. -FIRE EXTINGUISHER FIN.Fm F . 0 . M L. -FACE OFF FMASONRY F.O.S. -FACE OF STUD SQ.-SQUARE S/S.. -STAINLESS STL. S S-STEEL STEEL STRUC. -STRUCTURAL • MTD . _SAFE WASMOUNTED , SURFS.W. P-2 WATER AND GAS PLANS AND RISERS CONCRETE BLOCK F.R.P. -FIRE RATED PANELING F.S. -FLOOR SINK FT. -FOOT FTG.-FOOTING GA. -GAUGE T&G -TONGUE AND GROOVE T.O.S. -TOP OF SLAB TYP. -TYPICAL UR. -URINAL COMPACTED EARTH ► o p GRANULAR 4 - FILL BATT INSULATION RIGID INSULATION GALV. -GALVANIZED G.C. -GENERAL G.P.M. -GALLONS PER TMMAICNUTE TOR G W. . -GREASY OUNDD WASTE GYP. -GYPSUM HORIZ. -HORIZONTAL HT. -HEIGHT -HOT WATER H.D. -HAND DRYER H.P. -HORSE POWER, HIGH POINT VEN. -VENEER VERT. -VICAL VEST. -VESTIBULE V.T.R. -VENT THRU ROOF W. W/-WITDrE� , WASTE W.C. -WATER CLOSET W.C.O. -Way CLEAN OUT W.H. -WATER HEATER W.I B. -WALK IN BOX W.P. -WATER PROOF W.W.M.-WELDED WF. -WELDED IRE MESH _ F L I Q� E —1 ELECTRICAL LIGHTING PLAN E — 2 ELECTRICAL POWER PLAN E — 3 ELECTRICAL PANELS & RISERS E-4 MASTER CONTROL SYSTEM (BASE BID) E-5 P.O.S. SYSTEMS 1 m n. W. CA u w ZONE 'E' ZONE 'D'- Tx. �• S.C. IX. M. LONE lLl.' .' �°" • � tL, r. ��}� a,� _ it q _ R. ZONE 'E' g ' j ft <�. �.Vier, C"OLIMA010-olloomwo Boom mm� F 13 W 1= R BID ITEMS QQti4'r I.C. N.I.0 �t Na� GAS HEAT AND COOK 1" ' ELECTRIC HEAT & GAS COOK NATURAL GAS PROPANE GAS , 120/208V WYE _ r - 120 /240V DELTA = ; f ROOF SHINGLES CLASS "A" FIBERGLASS f BARREL TILE A GLAZING 1/4" FLOAT GLASS 1 INSULATED GLASS . BUILDING CODE '+`r OCCUPANCY CLASSIFICATION T � :�.-- _r: �`- �•,y TYPE OF - . 1. : ' , ... CONSTRUCTION F_ OR,1F, s """-Li'' • � r dt<} ,fY i c 1. ROOF OPENINGS FOR A/C UNITS ARE BASED ON 'CARRIER' EQUIPMENT. IF DIFFERENT MFR.IS USED. G.C.SHALL BE RESPONSIBLE FOR COORDINATION W/MFR.AND SUPPLY SHUT DRAWINGS FOR INSTALLATION. FOR ROOF OPENINGS REFER TO ROOF OPENING SCHEDULE THIS SHEET. 2. IF REMOTE COLKESSCAS ARE USED, CONTRACTOR SHALL COORDINATE INSTALLATION W/E(XIP'deJT MANUFACTURER. 3. SEE SHT.A-5 FOR DET.CF SCUPPERS. ROOF DRAINS, ROOF PEN-TRATILM. PITCH PANS AND SCUTTLE. 4. SEE SHEETS A/C-2 FOR MOWING DETAILS. 5. STRUCTURAL DESIGN CRITERIA= LIVE LOAD - P.S.F. DEAD LOAD • 14 P.S.F.o ACTUAL MECHANICAL LOADS. WHfN BARREL TILE IS USED, MANSARD TRUSS DEAD LOAD • 24 P.S.F. 6. TRUSS MAN F.TO SUBMIT SHOP DRAWINGS FOR APPROVAL, PRIOR TO FABRICATION. 7. SEE SHEETS A-6 & A-7 FOR DETAILS OF TRUSSES & MANSARD FRAMING. 8. ALL HCRIZ.FRAM'G LUMBER, INCLUDING 2X JOISTS, BEAMS AND HEADERS SHALL BE DENSE NO. 2 DOUGLAS FIR -LARCH OR BETTER. 9. ALL WD.STUDS SHALL BE NO. 2 DOUGLAS FIR -LARCH OR BETTER. 10. ALL WOOD CCLUklNS SHALL BE DENSE NO. 1 DOUGLAS FIR -LARCH OR BETTER. 11. ALL BEAM SPLICES SHALL OCCUR OVER SUPPORT COLUMNS. 12. IN ORDER TO ACCOUNT FOR DRIFTING SNOW, ROOF DEAD LOAD AND HNAC EOUIPtrENT LOADS, AN ECUIVALENT TOTAL UNIFORM ROOF LOAD OF P.S.F.NAY BE USED FOR ROOF TRUSS DESIGN. 13. ROOF TRUSSES TO BE 2'-8' MAX. IN DEPTH o LOW POINT. IF DEEPER RO F TRUSSES ARE REQUIRED, PLEASE NOTIFY ARCHITECT IMMEDIATELY. 64 4=4 ROOF OPENING SCHEDULE MARK SIZE LOCATION WEIGHT REMARKS AC-1 48'X37' DINING AREA 780 VERIFY W/ HNAC SUPPLIER AND SCHEDULE SHT. A/C-2. AC-2 48'X37' DINING AREA 780 AC-3 48'X37' ' KITCHEN 900 AC-4 46'X37' KITCHEN 900 EF-1 23'x23' BROILER 120 _ EF-2 22'X22' FRYER 120 EF-3 17'X17' RESTROOM 60 SCUTTLE 37 1/4'X31 1/4' CREW ROOM SEE DET. SHT. A-6 (0.H.) (FACE OF PLYWOOD �TOYFACE OF PLYWOOD) 76'-0° BEAM SCHEDULE MARK SIZE TOP ELEV. LOCATION REMARKS GT-1 1'-10' 11'-6 1/2' BLD'G PERIMETER OBL.PRE-FAB GIRDER TRUSSES GT-2 22' TO 31' VARIES BLD'G FRONT DBL.PRE-FAB GIRDER TRUSSES NOTE, GLUE LAMINATED BEAMS ARE AN ACCEPTABLE ALTERNATE. ROOF FRAMING PLAN SCALE: 1/4"=1'-0° I LL ��j (9 ( :,, i • 7 - .. . ur.4i&'� «. --.a . � -^ S may. �.. M..aY ' �> C`- � - + a.s+ �P.4�4 .Y `•a MN.f. �: i T` r ... � ^.�F,t C .�S y'9e . Y ',Y , " � .`.. .-Y •." ST•' PJ 4'.+,.�> ,. ..- v��y9 f�, •'�j("��u' , c� tRE :`����an�Y�i�' ''"'��1Cy[8y�."cs�t�`iC ice" ; +d'fi.�.�:i�+A'� r�.-...a'ai'+` �; _ �fi13.�y. �r ]SlitilS"�YX1r7�tK..i�C �t•.Cs•� i _-�i��L~��Y41�`�ftiYII.1�� '� to w�,�.-¢5'. � ...lik3iil 3.tr-"r' � - ' ..7t-s,,{t;��..t� d �� t 1' MM%�AQSF�A�?. i.�, . � , �, � • .l .P�Xii'�f. S�.di3�� �1S}4+/P. �. STANDARD SIZE FACE BRICK " SEE FIN. MATERIALS LIST FOR TYPE & MANUFACTURER. METAL FLASHING (30 MIL MEMBRANE --� FLASHING OPTIONAL) WEEP HOLES o 2'-0" O.C. TOP OF SLAB +0 ' -0 " 10 1/2"CDX PLYWD.OR 1/2" 2-M-W "V_ 2 1/2" WAFERBOARD (UBC SfD 25-25) (TYP.) 1l i Z - 5/8"GYP BD.ON 2X4 WD.SfUDS o 16"O.C. 5/8"OX81LG.A.B. 0 48"0.C.(TYP.) FULL BED OF SEALANT UNDER BASE PLATE (TYP.) 4"CONC.SLAB W/6X6 10/10 W.W.M.,OVERLAP MESH 24"(TYP.) x Y x x x TX o ' r ' f � P Y #3 STIRRUPS o 48" O.C. (TYPICAL) 6" LAYER OF WELL COMP. GFWULAR SOIL (TYP.) CD MIL VAPOR BARRIER, LAP AT END OF SLAB (TYP.) PROVIDE 2" STYROFOAM INSULATION (R-10.75) EXTENDED 3'-0" MIN. UNDER SLAB, TYP. FOR ZONES A&B, USE IN OTHER ZONES ONLY IF REQUIRED BY LOCAL CODES. SEE FOOTING SCHEDULE, SHT. S-1, FOR SIZE & REIN. OF FOOTING TYPICAL FOOTING DETAIL SCALE: 1. 1 ' -0 " COL. 4X4 WOOD COLUMN W/ "SIMPSON' LCB-44 X x\��l �X X ?MIL o o <D VAPOR BARRIER J'-- SEE SCHEDULE I SEE FTG . SCHED .SHT . S-1 FOR SIZE AND REINF.OF FOOTING (TYPICAL) WOOD COL. FOOTING DETAIL SCALE 1"-1'-0" SIMPSON STRAP TIE #ST6224 W/ 28-16d NAILS PRE-FAB GIRDER TRUSS I E h2 1/2" TYPICAL COLUMN FOOTING DETAIL SCALE: 1" 1'-0" 111111111111�1�111111111111 10"X1/4" "U" PLATE W/ 16 d NAILS (8 EA. SIDE TYP.) 4X6 WD. COLUMN — 10"X1/4" "U" PL,'T1 W/ 16 d NAILS co m 4X6 WD. POST TYPICAL BELOW ° �_ �a 0 0 0 0 COL. I ELEVATION PLAN VIEW E COL. C`T{in0n),I r_rnAn MOP SINK SLAB DETAIL SCALE: 1" =1'-0. 4" 10"— E 2 1/2" 7 1 2 REFER TO TO SHEET A-7 FOR TRIM DETAIL. _ 2X BLOCKING AS REQUIRED - SHOT k--,\. TO SLAB. I TOP OF SLAB -0'-0' R OPT. SIDEWALK 5'-0" HIGH 18 GA. S/S PANEL (2B FINISH) o ALL CAN WASH WALLS OVER 5/8" EXT. GRADE (MARINE) PLYWOOD. PROVIDE FULL HEIGHT FRP ABOVE 5'-0". S/S PANELS TO BE CAULKED ALL r AROUND AND SCREW FASTENED TO THE WALLS SILICONE SEAL ALL SEAMS & PENETRATIONS. CONT.2 1/2"X4"X1/4" STL.(LLV) PAINTED BLACK W/ ANCHORS Af 12" O.C. FLUSH W/ TILE I 2'-0" ' X ��—k—�-_X— -- 0 vc:�380 �O Till lit { . J r. Y. V. unt%II r 1rC 4"CONC.SLAB W/6X6 10/10 W.W.M.,OVERLAP MESH 24"(TYP.) GIRDER TRUSS ALONG FRONT OF BUILDING 0 I SEE FOOTING SCHEDULE, SHT. S-1, FOR SIZE & REIN. OF FOOTING FOOTING DETAIL @ RESTROOM SCALE: 1" 1'-0" ELEVATION MOP SINK SLAB DETAIL SCALE: 1" = 1'-0. FRONT CORNER ISOMETRIC N.T.S. FOR ADDITIONAL INFORMATION, REFER TO FRONT CORNER ISOMETRIC THIS SHEET. N `? GIRDER TRUSS N N 1k — T N 3X4 TOP PLATE BOTTOM OF 4'-6' EDGE OF SLAB TO ROUGH OPENING STD . ROOF I 4 ' -0 " - TRUSS & BOTTOM OF 3X4 TOP PLATE — r-t—r r- GIRDER TRUSS ALONG SIDE OF BUILDING 3 1/2"Lj_ _p 8N L 8 1/2"X 1/4" �I , 'U" PLATE W/ 8 1 /2" I ANCHORS-'�I 16 d NAILS BOLTS II • •I� - II II .I► y E COL. alv . 1-"-- i -r WOOD COLUMN TYPICAL BELOW `'' TrG-T-1 COL. PLAN VIEW %" CDX PLYWD BOTH SIDES 10d o 3 EDGES 10d o 12. FIELD BLOCK ALL EDGES. GIRDER TRUSS W/A' PLYWD. FILLER. FILL WEBS W/ BATT INSULATION (R-11) ST6236 STRAP BOTH SIDES 06 WOOD COLUMN (TYP) HD-20A W/ 1%"(D X 20" ANCHOR BOLT AND 4 - 1"m STUD BOLTS (TYPICAL) FOOTING TYP. GIRDER TRUSS CONN. TO WOOD COLUMN SCALE: 1 112' - 1'-0" 10 GIRDER TRUSS CONN. TO LOAD BEARING PARTITION SCALE: 1 1/2" - 1'-0" GIRDE;�, T�JSS END CONN. HOOD COLUMN SCALE: 1 SHEAR WALL _�G>ELE/ATION SCALE: 3/4' - 1'-0" v F-ei w:i: SHEAR WALL SCHEDULE touTICN SEISMIC ZONE WIFD LOAD - 24 P.S.F. PLYWOOD OR 'WAFERBOARD 1/2'COX " BOTH SIDES NAIL- BOUVARY & EDGES -FIELD 10 F&tfe AT 3'O.C. O1NG G 10 PENIY AT 12'O.C. ANCHOR BOLTS 1'0 A.B.AT 16'O.C. SIMPSCN FD.D-DOWN EACH DO FD-20A DETAIL / REMARK 3X4 STIRS (OR DaJBLE 2XV S) 0 16' O.C. - 4X6 COLLMIS EA. END PLYWOOD OR WAFERBOARD 1/2'CDX ' EXTERIOR SIDE NAIL- BUMARY & EDGES 8 PEMIY AT 6'O.C. F O ING FIELD 8 PENNY AT 12'O.C. ANCHOR BOLTS 5/8',P A.B.AT 32'O.C. SIMPSON HOLD-DOWN EACH END NONE DETAIL /REMARK PLYWOOD OR WAFERBOARD 1/2'CDX ' EXTERIOR SIDE NAIL- BWDARY & EDGES 8 PENNY AT 6'O.C. OIP'G E FIELD 8 PE lY AT 12'0.C. ANCHCR BOLTS 5/6'm A.B.AT 32'O.C. SIAf'SCN KLO-004N EACH c'TD FD-2A DETAIL / REMARK DBL. 2X4 STIRS EA. END PLYWOOD OR WAFERBOARD 1/2'CDX ' EXTERIOR SIDE PINAIL- BOI.PDARY & EDGES 8 PENNY AT 4'O.C. D O NG FIELD 8 P&VY AT 12'O.C. ANCHOR BOLTS 5/8'9 A.B.AT 24'O.C. SIWWI HOLD-DOWN EACH END HD-2A DETAIL / REMARK n.+u H m OR , _8 �5 EDGE OF STORE-' FRONT SYSTEM (TYP) IYP6��`4ffii�3�.`�tliS.�L3i12$1-'14Y.�fa:lA� 9138YRM;fw4taSAC�YI�Wh�Y6l5i�AYY:tva[arl.iiffi"i.+f.'SY�ibix"eliMr:•%+S'e':wd^:fk�T_aurtlaixurt.•auatvnaaur:x:'us:nw�wtw.�.4h.sxN.c•<aw�.�Yawrs�auu..a..tri".nu:x w.w..un�...r..:.w.,.. i' fi 3 9 OAK WIPlDON 5/8 P►_ WD. BLOCKING (FROM FACE OF BRICK TO FACE OF BRICK) SILL ON TWO SIDES OF POST o " AS REI ' . D �" i j _ w x ., 7 1/2" WA8LBOARD LINE OF GIRDER I 10'-6" 22'-0" 39'-8 1/2' TRUSS ABOVE 's 10 1/2 6" �0" '?x1- i 10'-0" 10'-01, 21 — 15'-7" 5'-4" 24'-4 1/2" 5'-4" I I M. 0. M. 0. ; -Or 29'-8 1/2" 4'-2" PROVIDE 10"X10" FINISHED OPENING THRU WALL CENTER AT 1'-1" A.F.F. FOR ROUTING OF B UTILITIES 24' -6 (TYP.) r— — — — — — — — — — — — — — — — — — — — — — — — — — — — — — �-- — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — I I I 1 B 3 1 1 -1 u iv R-3 -1 I I 3 4" STL. GUARD POST (TYP.) I I 7 r I A-1 SIM. — — — — — — — — - — If 11' - — — — — — — — — — — — — — — — — — — — — - r � c`t c� ZDRIVE-THRU II N� DRIVE-T."(D WINDOW "2 j r CENTER LINE OF WALL u_)m & EDGE OF SERV, COUNTER WINDOW "1 I jjp INSIDE MENU BOARD SOFFIT ABOVE D PROVIDE BLOCKING I -7 I O I FOR SHELVING I I I (SEE EQUIP. SHEET) FREEZER I i i I S RVINd i I CUSTOMER AREA �I KITCHEN I I DINING ROOM PICK-UP T r i II II 10, 10 1/21 32'-3" a -6Y 1'-1/2" I 35 4° I I I PROVIDE S/S ANGLE 2 = = I AT ENDS OF W.I.B. COOLER -3 II II AS REQUIRED (TYP) R-3 I I 4" Ill 15' I 5° 5" I „ I 1111 9Y 3'-4" i t 9- 1 1 o 12 O/2 10'-3" II I N o 0 I I I i i r H-' I PARTITION BELOW lI II ;SJFE ELECTRICAL PAtJELS" 6 COUNTER BY 4 COMPLETELY WRAP 8 RECE S FOR GAS 3 ccG.C. (REFER TO I I PROVIDE BLOCKING A_1 WALL ENDS 'N/ O S, JT- VALVE o0 mDETAILS ON IFOR WALL MOUNTED CORNER GUARDS o 60, A.F.F. oSHEET EQ-1.) SHELVING (TYP) (S SHT. P-2) r, U 0 — .ICE -, F�,CORRIDORI LOCKERS MQPSOFFIT AT " 45 �'�(N.I .C.) � SIrJK I I 7 0 A.F.F. 5�1 5" Lk-/ ,(_—,D'- ' .,� 3'1-6" I �ILECCABINET I ALTERNATE DOOR LOCATION. ;�' MEN'MEN'S CRT TOIL T[J—PN.I.C.FVERIFY DOOR SWING AND" I LOCATION WITH OWNER. H D. in � I II I = _ CONTROL A EL TRAINING RO CUTTLE EE 1 _ & STER- CABINET DET I 3 SHEE A-5 - R ► \ ftEA _ r , A I R-3 A51 �_� WOMEN �.� 8 N rN.C.' �;�.� `� Vi.0 5' 5" - - _ = ll TOILET r 7'-2. 21 7,1 _�1 2, 0" -6 r ,, JII STORAGE ,C I 01vc lAREA -2-io r i-- - — —( 11 CO PROVIDE BLOCKING BETWEEN STUDS T 1 {AT ALL PLUMBING FIXTURES FOR Ail SIM I ' A 3 ' 1 I 9 \ `'�` `' A-1 SUPPORT OF WATER LINES (TYP.) I O L—. — — � — — — — — — — — — — — — — — — — — — — I — — — — — — — — II SEALANT W/ BUTYL BACKUP (TYP) 1/4' SHIM AS REQ'D. (TYP.) LINE OF PLYWD. BELOW (TYP.) i ° r 1 FACE OF INT. WALL :i STOREFRONT SYSTEM - SEE SPECS. OAK WINDOWSILL 1X OAK TRIM 5' 4X6 WOOD COLUMN 3° lox, COLUMN AT WINDOW CORNER O I I 5" 5'-q" 5'-�" r n 10'-016 10'-0° 4'-8 1/2' 6'-4" 5" I (M. 0. I I 1 Y I I n 1 Y 10 -6 10 -6 11 -6Y 6 -0 72'-10" (FACE OF BRICK TO FACE OF BRICK) At riu ❑neev FLOOR PLAN SCALE: 1/4"=1'-O" (TOTAL GROSS AREA= 2820 SO. FT.) 3/4" STUCCO —iCASING BEAD (TYP.) BRICK ROLOCK COURSE SILL — — — — `n COLUMN AT WINDOW WALL 23,-9" " (BRICK) I 7" 33'-8 1/2" n n n n o y2ho X2h" X60" I16 GA. S/S ANGLE n N — — — SET IN MASTIC. n rrN ,r!/! ,n!! .r!/! x 1 n n 1X2 OAK TRIM ' W/RAD . EDGE R-11 BATT INSULATION WITH VAPOR BARRIEF ON INSIDE FACE OF STUDS (TYP) SEE DECOR DRAWINGS FOR WALL FINISHES DETAIL AT WINDOW WALL 3 ,OUNTERz)u,^ HEAD S/S )CREWS 0 16 " O . C . (,rYP ) FRP BOARD 5/8"TYPE"X" GYP. BD. QUARRY TILE BASE PLAN VIEW PROVIDE SILICONF FLEVAT I ON SEALANT ALONG BAsF [ . SCALE: 3'•1'-0" OF CORNER GUARD :KALE: 1 112'-1'-0' CYP.KITCHEN CORNER GUARD C -7 10 0 0 r t O VENTS SEE SHEET A-2 5' ROOF DRAIN LINE SEE SHEET P-1 i O f '11 MAIN ENTRANCE � ALTER' ArF SCALE: 1/4' - 1'-0' BRICK ROLOK COURSE (TYP.) EDGE OF BRICK BELOW N�� ..I. 4 / FACE OF INT. WALL STOREFRONT SYS"(EM -SEE SPECS. 5"Y DOUBLE WINDOW CORNER DETAIL SCALE: 1 1/2" •1'-0' ■■ ff fv �t r pe: '1 -r ORIVE- T}HU I •• ' I / WINDOW • • • . � / ( BEYOND) 4' DIA. STL. PIPE O• OF -PNOPET LIGHT ' •••+ TILE IS USED.) .�ww•�I awwME to 12 ENNEE u 121 .�wiwiw■ • /rw�wwwwwl MENNEN /wwwwww■I 1•E••I ©, 31 • OF SILL Iu111rrlrrrrlrlrl/trtl •wY.��a�.rr w�� rr wrrrw.ww.i •r w�.a.+w •+ww•i'•r r � r. • ..rww rrwr,w w�„•�Mrr��. r r�rrrr•M wr.wswr......r, .w�rr w�r•r •, r rMr•�•rl 0 /AV •ww•wrwvww� T. 0StA ` AJ.5'-6' T.O. PARAPET LIGHT BAND x r r ),"ARD SIGN (N.I.C.) G.C. SHALL PROVIDE ANY REQUIRED SUPPORT I 0 I 4'X12' 18 GA. GALV. MTL. SCUPPER(TYP.) ALL EXPOSED SURFACES SHALL BE PAINTED SHEET METAL CAP DARK BRO fZE . ALL JOINTS SHALL BE SOLDERED. SEAL ALL EDGES (TYP.). •- Y �.• (ADD 3' IF BARREL TILE IS USED) ' • LIGHT FIXTI.RE • (TYP.) 15'-6' TOP OF PARAPET I.IGNT BAIT IV (ADD 3' IF BARREL; :.� ' •. ' ,' TILE IS USED . ) 91 -on • : • E30T : CF SOFF I T li i11111111111/1111111111111111111111111I4illIs lli • 11 111111 • IIri1i11111i1111ii11i11i1 tt1i1 • Ur111111Ui1r11r1ir1i11i1111101/IIIIIr11iI111H1ir11//1/itfllr1111111/1/111111111U1H11i1111/11tIt111111rI1U1U iwrw•r3•irr�wi�'wwr •'� �� �'..� w�Y••ir•i••r�..ir���• •��r�w•.�rw�riw�i • w•�•rrwwrr..w��rw rsn..rwr r� r�wr �rwsrwrrarwrru.r.. - ::i ,.rrrr •..w;r`•ii .T.•rrw ter• �r••.��.w��i•.r��.wi•�•r.'�i�•�••ww� ••.�.r�a��•••iw���rwrwaw..�.rw..rr�•� ,Tr w�rr �. �w�rwrw•wl .wi' � .r ••rr•��.. r.rr 1 ;, iwrrr�ii�rrw�wrrrr•,+ • ��•• �•, .. ww •r�.s.w.wwrwsw•rr�r.T ri•� ..�i'• " �rrrw�.rw�rr�•w �1 w�Mr�•�.1�����•�� _�r1�l���r/�.��.y�w Y�w� .:",: irrr•rr���rrr�ww� r+ -- - �r wrwr�s.rrw�,,,s.�•iww, irw�ii�.rw�w.•rwr•wrww t•rr� rww.rw�.rrrrrr. VERIFY DOOR LOCATION - - -� AND SWING. FRONT ELEVATION S3 SIM. SCALE! 1/4' - 1'-0' J SHEET METAL CAP CONT. RED PARAPET LIGHT 2 BAND. (TYP.) SEE DETAIL "3 2 SHT. A-3. FIBERGLASS n n f SHINGLES (TYP,) ' I Pr METAL DIVERTER O BRICK ROLOK / COURSE (TYP.) FACE SAND FINISH FULL BRICK BRICK (TYP.) •718' STUCCO 1 (TYPICAL) MAIN ENTRANCE ELEVATION SCALEt 1/4' - 1'-0' ULU- VllIL. vn NUJ. 1 L1n LJLI . DRIVE - THRU ELEVATION SCALE, 1/4' • 1'-O' 5' -0'X5'-O'SI,.AFACE MOUNTED BURGER KING LOGO(N.I.C.) STUCCO CONTROL JOINT �_j SEE DETAIL BELOW. 2 STUCCO TRIM, SEE DETAIL THIS SHT. AND W . A-7. 2 0 Y O SLAB 8'X16' ST" PROOF MTL. 'LOUVERED BRICK VENTS, SEE SHEET A-1 FOR LOCATION 4 REAR ELEVATION SCALE: 1/4' 1'-0' O XTER10 AI PEG FTCAT._IONC� FOR St.FMfACE PF&ARATION AND PRIMING, PAINT CONTRA" %Wl VEER TO SECTION 'PAINTING AND WALLC0NEAINR' s , s OF BUILDING SPECIFICATIONS. �r OTHORO SYSTEM PRODUCTS, 2 COATS OK-200 T TAN JF! i lw (TEXT., COATG.) AND.2 COATS 'TF iIELD-(CLEM ) � Og&" PAINT - SCUD C ATEX STAIN COLCR� SC-56 lw MAD (2 COATS) LL O PCOL R 3 I'19ASsw0Ob I ( COATSCOLOR ) STAIN ODOM!COLORl PIB Aii TOW. ( TTWSM PAINTCOATS) 54-LINE 'GUItaC DRY CUFNESPQDING CCL" BY SHERWIN WILLIAMS CA BM7yUIN 2X4 *000 5/81 DRYWALL cc NOOK ARE APPROVED ALTE"TES. STUD —WALL . BAIT 1/2' COX PL YD NOTE INSULATION twin kaz FOR EXTERIOR MATERIAL FINISHES, FEFER TO 'FINISH MATERIALS LIST' 'fit r' - • � � _. _. S�TUCCO�At� r` � � . o 17 , y. / T ON 15" FELT 00 ol 10 dk i '1 1s41 r 1 1/2' COX PLWD .SEAL91T TO ►.•, �� •` 3/8' BACKER RGO STUCCO AND METAL LATH ON EDGE OF BRICK BELOW }. 1 1/2' THICK X 4' WIDE ' INSULATION BOARD EDGE OF ROLOK COURSE STUCCO TO BRI CK MUCCO CONNECTION DETAIL a MAIN ENTRY ELEMENT SCALE: 3 4.1 `0' METAL LATH 150 FELT BACKING PAPER 1/2' PLYWOOD SHEATHING- 1/4" I (� - �- -- 7/8 3 COAT STUCCO USG CONTROL JOINT 0100 STUCCO CONTROL JOINT SCALEt 12' - 1'-o' qua crnrt .:.¢.o-,.e�.rsda�ais +i �-:awg: ..�--. �tyrsaum�B.saw:7nai7_vr�ASaX+,+a£+'�7sWtFitmmiaCAi°ffi,e+.xr_�'#J4*wA:at�Y��.Y: 1 12 F(T j ---------- I { ' I BLDG. CROSS SECTION SCALE: 1/4" = 1'-O' CERAMIC TILE - SEE SHT. A-8 FOR SPECS. (TYP.) ELEVATION 1 ELEVATION 5 IJLI I rw L-U%J l I ntu I 1 . BLDG. CROSS-SECTION SCALE: 1/4" = 1'-0" ELEVATION 2 CONTINUOUS CERAMIC TILE ACCENT BANDS - SEE SHT. A-8 FOR COLOR & SPECS. I r _ 7 � 2 ELEVATION 3 N r +15'-6" A.F.F. r T.O. LT. BAND/PARAPE 3" IF BARREL TILE IS USED +14'-6 1/2" A.F.F T.O. PARAPET D 3" IF BARREL TILE IS USED N i Lo t9'-O" A.F.F. BO I OF�GOFFIT 0 +3'.-0" A.F.F. TOP -OF -SILL FOR FOR TYPE OF EXT. FINISH "o SEE SHTS. A-6 & A-7 -EL. 0'-0" �TOfsOF-FIIJ_F[_._ ELEVATION 4 ELEVATION 6 ELEVATION 7 RES TH- 00M ELEVATIONS ` SCALES 1/4" 1'-0" ri��g ELEVATION 8 LEGEND O GRAB BAR -250 LBF (36" MAX. HEIGHT) O2 WALL MOUNTED HANDSOAP DISPENSER (36" MAX. HEIGHT) �3 MIRROR (BOTTOM o 40" MAX. HEIGHT) ® TOILET PAPER HOLDER (19" HEIGHT TO E) O RECESSED HAND DRYER (40" MAX. HEIGHT) Nm : 1. ALL TOILET EQUIPMENT SHALL BE SUPPLIED BY THE G.C. 2. FOR FINISHES REFER TO INTERIOR FINISH SCHEDULE. RESTROOM PLAN SCALE: 1/4' - 1'-0" - '-6" A.F.F. PARAPET I" IF BARREL S USED . ) FOR TYPE OF FINISH SEE SHTS. A-6 & A-7 i0 , -0 " T-FCO OUTSIDE FACE OF STOREFRONT CAULK t o CifCL s s (o o co Y cn BRONZE 41WIZED ALUMINA FRAME 2"x2" SILL W/ BREAK METAL TO MATCH D/T WINDOW SILL TOP OF +3'-0" CA SILL A.F.F. BRONZE ANODIZED ALUM.WINDOW SI►_L PROVIDE BREAK MTL. FILL TO PLYWD. MANUFACTURER D/T #1&2 READ Y ACCESS 19 "x18 " SEMI -AUTOMATIC BO-2S M.C.E. WINDOWS "QUICKSERV" 15"X19' SEMI -AUTOMATIC PW-1 D RIVE-THRU WINDOWS MOUNTING DETAIL SCALE: 1"=1'-0" ROOFING SYSTEM (SEE SPECS.) WOOD DECKING SEE ROOF FRAMING PLAN 2x4 o 16'O.C. NAILED FLAT TO TRUSSES 9'-2" A.F.F. CLG. HGT. 6 PANEL PREFAB.MENU BOARD (N.I.C.) ATTACHED TO 1/2" PLYWOOD SHEATHING (SECURE AS REQUIRED) MENU BOARD DETAIL SCALE: 3/4" - 1'-O" TOP OF PARAPET 1 irUT RAAIn TOP OF PARAPET 14'-6 1/2"° SECTION SCALE: 3'- 1'-0" N Lo N WOOD TRUSSES (TYPICAL) 2X4 BRIDGING 5/8" TYPE"X' GYPSUM BOARD CLG.HEIGHT 8'-6"A.F.F. oo w 1X OAK TRIM _N � r O CO a_ O )_PARAPET CONT. BRONZE ANOD. ALUMINUM CAP FLASHING ANCHOR EACH FRAMING MEMBER TO WOOD PLATE. (TYP.) SEAL ALL PENETRATIONS DBL. 2X4 WD. TOP PLATE (TYP.) MET. CLIP ANGLE AT 4'-0" OC. (TYP.) BY AWNING INSTALLER. WIRING TO LIGHTING FIXTURES BY ELECT. CONTRACTOR. i BRONZE ANOD . ALUM. FLASHING (-[YP_: -) 1-PLY ROOFING MEMBRANE OVER { 112" COX PLYWOOD (SEE ROOF SPECS.) (TYP.) 2 1/8'X4" (2-GANG) WEATHERPROOF, CAST ALUM. OUTLET BOX WITH GASKETED BLANK COVER & THREADED CONDUIT OPENINGS. CONNECT TO EXISTING PARAPET LIGHTING CIRCUITS OR PROVIDE CIRCUITS AS SHOWN. LOCATE BOXES WHERE SHOWN ON SHT. E-1 (ELECT. ROOF PLAN), MOUNTING HEIGHT- 18' ABOVE FIN. ROOF (TYP.) SEAL ALL PENETRATIONS. t CONT. RED PARAPET LIGHT BAND (TYP.) T.O. LIGHT BAND r 15'-6" BURGER KING SIGN` (ADD 3' IF BARREL (N.I.C.). CONN. AS TILE IS USED) PER SIGN MANUFACTURER T.O. PARAPET REQUIREMENTS. (BEYOND) +14'-6 1/2' (ADD 3" IF BARREL TILE S USED) _N f BRONZE ANOD . ALUM. J 3"x3"x1/4" STL. ANGLE FLASHING (TYP.) OUTLOOKERS (3'-0' LONG) AT 4'-0' O.C. BY G.C. _ 0 T.O.TRUSS 12'-0'(o LOW POINTT) - 12'-9"(o HIGH POINT) FIBERGLASS SHINGLES ON 30# UNDERLAYMEN-r ON 1/2' PLYWD. SHEATHING (TYPICAL) METAL HALIDE J LIGHT FIXTURE (TYP.) T 1-11 SIDING, SEE SHT. A-8 FOR MATERIAL SPECS. 2X10 CEDAR (SMOOTH SAWN) SEE PAINT & FINISH NOTES ON SHT. A-2. 4'-0' (OVERHANG) 3/4' STUCCO ON MTL. LATH OVER 1 LAYER 15# FELT OVER 1/2' COX PLYWOOD (TYP.) ROLOK COURSE _ (TYPICAL) o� 3X4 P.T. WD. BASE PLATE W/ HOLD DOWN ANCHORS & ANCHOR BOLTS. SET PLATE IN FULL BED OF SEALANT �—� (TYPICAL) TOP OF SLAB =L.. -0'-0' NOTE o. 3 A-3 OPTIONAL VESTIBULE SECTION nD SCALE: 3/4'-1'-0" T.O. LIGHT BAND 13 GAGE HANG-UP HANGER 15'-6° -- - NAILED TO UNDERNEATH OF TOP (ADD 3" IF BARREL TILE IS USED) CHORD ® 16' O.C. MANUF. BY r PRO -WIRE CO. - (1-800) PRO -WIRE - T.O. PARAPET OR EQUAL. (TYP.) +14'-6 1/2' (ADD 3" IF BARREL TILE IS USED.) FOR ROOFING MATERIAL BETWEEN TUSBIS.ESKING REFER TO SPECIFICATIONS. FIELD ADJUST VERTICAL o 5/8' TYPE 'X' GYP. BOARD CHORD TO SLOPE. UIC. CENTER G(TYPICAL). co 5/8' TYPE 'X' GYP. BOARD FIRSTOPPING u 20'-0' O.C. CENTER (TYPICAL). BATT INSUIL . (R-30 ) (TYP. ) 11 �-- 1X2 OAK TRIM (CONTINUOUS) 1/2" COX PLYWOOD (BOTH SIDES) EXTEND INTERIOR TO UNDERSIDE OF ROOF DECK. SUSP. ACOUST. TILE �J CEILING (TYP.) I 3X4 WD.STUDS 2X4 WD.FIRESTOP I (TYPICAL) 5/84TYPE"X'GYP.BD. (TYPICAL) 3 1/2"BATT INSUL. (R-11) (TYPICAL) /(�i SIM. A 4°CONC.SLAB W/ 6X6-10/10W.W.M. (TYPICAL) x /x 2" STYROFOAM INS.(R-10.75) ADDITIONAL INFORMATION SEE FOUNDATION PLAN, SHT.S-1 ON FOUNDATION FOOTING _ _ _ (TYPICAL) AND FLOOR SLAB. TYP.FRONT DINING RM AALL SECTION SCALE: 3/4"-1'-0' T.O. GIRDER TRUSS 11'-6 1/2' O B.O. SOFFIT 9'-0" ° f o IT T.O. STOREFRONT WINDOW 8'-2" CONT. 2X4 (TYP.) PROVIDE PARAPET WALL VENTS IF REQUIRED BY LOCAL CODES. NOTE; SEE SECTION 'A', SHT. A-6 FOR TYPICAL NOTES. SIMPSON H2.5 FRAMING ANCHORS o EA. SIDE (TYPICAL). PREFAIT WD . TRL (TYP.) DBL. GIRDER TRUSS W/ 1/2' PLYWD: FILLER -FILL WEBS W/BATT INSUL.(R-11) 1X OAK TRIM (TYP.) 1/4' WD. SHIM (TYP.) 1X BLK'G. (TYP.) FOR GLASS TYPE SEE SPECS. BRZ.ANODIZED ALUM. MULLION 1 LAYER 150 FELT OVEH � 1/2' COX PLYWD. (TYP.)2 A-6 PROVIDE CORRUGATED NON- CORROSIVE METAL TIES o 24" O.C. HORIZONTAL & 16" O.C. VERTICAL, NAILED TO EACH STUD (TYPICAL) T.O.S.a0'-0" ( x age TYP. SIDE DINING RM AALL SECTION SCALE: 3/4"-1'-O" 2X° EDGE OF STORE- COLUMN FRONT SYSTEM (TYP.) i O STOREFRONT SYSTEM AK TRIM (BEYOND) SEE SPECS. (TYP.) PROVIDE 1X P.T. WOOD SHIM CAULK (TYP.) (TYP.) SEALANT (TYP) , FLASHING BY WINDOW SUPPLIER 1X4 WD. SILL(OAK) 3'-0" A.F.F. W/ RADIUS EDGE (TYP.) TOP OF SILL i 1X2 OAK TRIM W/ RADIUS EDGE (TYP) ROLOK COURSE SILL (TYP.) FLASHING - "AFCO' COPPER -� FABRIC 502/SF OR EQUAL " 2X BLOCKING 1 R-11 BATT INSULATION WITH VAPOR BARRIER ON EEZ INSIDE FACE OF STUDS (TYPICAL) 4' FACE BRICK SEE ROOM FINISH SCHEDULE (TYP.) , FOR INTERIOR FINISH 15# FELT ON 1/2' COX PLYWD. SHEATHING (TYP.) STANDARD SILL DETAIL SCALE: 3" 3 1'-0" NON-CORRISIVE METAL TIES AT 24' V O.C. VERTICAL & 16' O.C. HORIZONTAL. (TYP.) - STANDARD SIZE FACE BRICK oll- SEE ROOM FINISH SCHEDULE (SEE SHT A-8 FOR TYPE & FOR INTERIOR FINISH. r MANUFACTURER) (TYP.) - rn _ ol 5/8"( ANCHOR BOLTS 0 48' O.C.-SET IN CONT. GALV. METAL FLASHING PLATE IN FULL BED OR 30 MIL. MEMBRANE FLASH. OF SEALANT (TYP.) EXTENDED 6" ABOVE & 4' BELOW FINISH FLOOR (TYPICAL). NO F.R.P. OR CERAMIC TILE BEHIND BASE TILE. PROVIDE F.R Y. W/ TRIM PIECE OR TILE CUT TO FIT. PROVIDE 3/8" ROUND WEEP HOLES AT 24' O.C. (TYP.) - FINISH FLOOR PROVIDE EXP. JOINT AT ol EDGE OF BLDG. WHEN EXT. _- CONC. SLAB IS PRESENT. (NEOPREME BEAD & CAULK) _- c DENOTES PAVING WHEN I I FINISH GRADE IS NOT PRESENT. I I DENOTES FINISH GRADE WHEN CONC. -1 PAVING IS NOT PRESENT. TYPICAL FLASHING DETAIL 2 SCALE: 3' - 1' -0' M7 �, §j{� \ uj 0 V) ZQ . z 0 tr (L 0 Iff \ cr 0 C,Z z lz $§f�. to 06 GIV -1 g . : . .© �� \\ J N" STUCCO C MTL. LATH CASING BEAC SEALANT W/ BUTYL ROD BACKUP DOOR SCHEDULE DOOR FRAME NO , REMARKS SIZE DETAILS _ DETA_ILS SEE SPECS. W H _ T MAT, TYPE CLASS MAT. _ JAMB HEAD TFD. }D W•SET O PAIR. 7'-0' 1 3/4' AU.M. A T/E4' ALUM. A A A 1 SEE NOTES '2 .7 �2 3'-0' 7'-0' 1 3/4' ALUM. B 1/4* ALUM. A A A 2 SEE NOTES 02 ,7 O3 3'-8' 7'-0' 1 3/4' HOLLOWMETAL C - HOLLOW METAL C C C 3 W/ PEEP HOLE SEE NUTES '2 & '4 ® 3'-0' 81-8' 1 3/4' � D - ALUM. B B B 4 SEE NOTES d3.115.06 CORRIDOR SIDE= WILSONART 87850-13 BEIGEWOOD' HPL RESTROOM SIDE= WILSONART D-373-6 BERMLDA 0 3'-0' 6'-8' 1 3/4' � D - ALUM. B B B 4 48 CORRIDOR SITES DE, WILSONART 17850-13 BEIGE'WOOD` HPL RESTROOM SIDE= WILSONART D-309-6 FAWN ® 2'-10' 8'-8' 1 3/4' SOLID CORE E - ALUM. B 8 B 6 SEE NOTES '3,05,'6 17B50-13 HP[_ BOTH SIDES= WILSONART BEIGEWOOD' 0 2'-8' 8'-8' 1 3/4' SOLID G - ALUM. B B B 6 SEE NOTES '5,'8,'7 GORE BOTH SIDES: WILSCNART 07850-13 BEIGEWOOD' HPL ® 2'-0�= 4'-B' 1 3/4' SOLID CORE F - ALUM. B B B 7 SEE NOTE '8 BOTH SIDES= WILSCNART D-309-6 FAWN AT WOMEN'S TOILET HPL d SEE NSIDES; O 3'-0' 4'-8' 1 3/4' � F _ ALMA. B B B 7 BOTH WILSONART D-309-6 FAWN AT WOMEN'S TOILET HPL WILSONART D-373-6 BEFO"A AT MEN'S TOILET 10 2'-6' 8'-8' _ 1 3/4' SOLID D - ALUM. B B B 5 SEE NOTES '5,'8,'7 BOTH SIDES= 'WILSONAAT 117850-13 BEIGE'WOOD' NCORE ' AS AN ALTERNATE, USE FORMICA '115-58 DERBY HICKORY WITH N1ATUiAL. OAX AND MARLITE O L 2% ° 1 DOOR SCHEDULE NOTES 1- SEE SPECIFICATIONS FOR HARDWARE SCHEDLLE. (COMPLETE HARDWARE PACKAGE 8- AS AN OPTION, IN LIEU OF SOLID WOOD CORE DOORS & HOLLOW METAL FRAMES, AVAILABLE FROM UNIVERSAL MFG. INC.) PROVIDE MAFLITE HPL DOORS WITH ALUMItk M FRAMES FINISHED IN 'BRONZE 'TONE, WITH ACCENT STRIPES TO MATCH DOLT? FINISH. 2- CONTACTOR SHALL PROVIDE PANIC HARDWARE ON ALL EXIT DOORS. 7- ALL GLASS WITHIN 48' OF ANY DOOR SHALL BE TEMPERED GLASS. 3- SIGN PACKAGE TO INCLUDE THE FOLLOWING= (1) 'KITCHEN', (1) 'LADIES', (1) GENTLEMEN, MD CORRESPONDING SIGNAGE IN GRADE 2 BRAILLE PER 8- RESTROOM STALLS H.M. FRAMES SHALL BE PITTSBtfRGFi PAINTS 20-LINE A.D.A. REQUIREMENTS. SIGNS TO BE FURNISHED BY DECOR SUPPLIER AND LOW LUSTER ALKYD, COLOR: 'BRONZE TONE'. INSTALLED BY THE GENERAL CONTRACTOR. 9- ALUM. KICKPLATES ARE MOUNTED FLUSH TO THE BOTTOM OF THE DOORS. 4- H.M. DOOR 03 & FRAME SHALL BE PAINTED WITH PITTSBURGH PAINT! 54-LINE DRY ENAMEL, COLOR: 'BRONZE TONE'. 10- VERIFY LAMINATE COLORS WITH OWNER. 5- H.M. FRAMES SHALL BE PAINTED WITH PITTSBURGH PAINT 20-LINE LOW LUSTER ALKYD, COLOR: 'BRONZE TONE'. 4 HINGES _ PLUS CORNER 6" cD 6" OPEN N r 6" cD 6" PEEP 'REINFORCER" HINGE HOLE ao _ KICK PLATE ¢ r Lo ON D ES(T'tP SIDES Opal TEMP. GLASS DOOR _TYPES ------- - GIRDER TRUSS WALL FIN. 5/8" GYP.BD.TYPI BRZ. ANOD. ALUM. FRAME NOTE: SEE DET.5 SHT.A-1 FOR CONDITION AT WALL CONNECTION. BRONZE ANOD. • I / ' ALUM . FRAME m -E A 4 112' SCALE: 1/4' _ -1'-0" 5 3/4" 1 -HEAD--DETAILS SCALE: 3" = 1'-0' 5 3/4" WALL FIN. 5/8' GYP.BD.TYPE X 2- 2X4 HEADERS MTL .DOOR FRAME NO DOOR o TOILET STALL _.DOOR 4ME 2X4 STUDS JAMB DETAILS SCALE: 3" n 1'-0" I ALUMINUM L — J THRESHOLD BY WINDOW MANUF . c= FIN. FLOOR cr FIN. FLOOR s \ N — T THRESHOLD DETAIL ^^ SCALF= 3" - 1'-0' 6 3/4' ALUMINUM THRESHOLD FIN. FLOOR Ll \j N 15" BLD'G. FELT 1/2' CDX PLYWOOD 3/4' STUCCO 2- 2X6 WD. LINTEL W/ 1/2" SHIM STUCCO STOP CAULKING MTL. DOOR FRAME WOOD BLOCKING W/ LAG SCREWS .LOW MTL. )R FRAME ;ING BEAD 2-2X4 WOOD STUDS )RTHER INFO. :AD DET . C )CCO ON .. LATH ROOM FINISH SCHEDULE NOTE ALL INTERIOR FINISHES TO MEET CLASS 'C' FLAME SPREAD RATINGS CLG.HGT' ROOM FLOOR BASE WALLS CLG. REMARKS AFF . MARLITE DINING ROOM QUARRY TILE 1 QUARRY TILE 1 & WALLCOVERING ACOUST. TILE 1 91-1' ON GYP.BD. 1 WALLCOVERING BY DECOR SUPPLIER MARLITE CUSTOMER PICK-UP QUARRY TILE 1 QUARRY TILE 1 & WALLCOVERING ACCUST. TILE 1 9'-2' WALLCOVERING BY DECOR SUPPLIER ON GYP. BD. 1 MARLITE SERVING AREA QUARRY TILE 2 QUARRY TILE 2 & WALLCOVERING AMT. TILE 1 9'-2' WALLCOVERING BY DECOR SUPPLIER ON GYP. BD. 2 F.R.P. KITCHEN QUARRY TILE 2 QUARRY TILE 2 ON GYP.BD. 83 ACCOST. TILE 2 8'-8' F.R.P. OFFICE/CREW ROOM QUARRY TILE 2 QUARRY TILE 2 ON GYP. BD. '2 ACCUST. TILE 2 8'-6' CERAMIC TILE '1 WOMEN'S TOILET QUARRY TILE 1 QUARRY TILE 1 ON GYP. BD. '3 PAINTT 8'-0' WITH ACCENT BAND '1 ON GYP.BD. 1 MEN'S TOILET QUARRY TILE 1 QUARRY TILE 1 CON ERAMIC ILEx31 PAINT 8'-0. WITH ACCENT BALD '2 ON GYP.BD. 1 MARLITE CORRIDOR QUARRY TILE 1 QUARRY TILE 1 ON GYP.BD. 1 UP AC(X1ST. TILE 1 81-6' TO SILL HEIGHT F.R.P. ON GYP.BD.3/ STORAGE AREA QUARRY TILE 2 QUARRY TILE 2 F.R.P. ON 5/8' PLYWD. AUGUST. TILE 2 8'-6' o CREW AREA WALL ONLY 5' HIGH S/S PANELS OVER MOP SINK QUARRY TILE 2 QUARRY TILE 2 5/8' MARINE PLYWD FULL HEIGHTT W/ FRP ABOVE 5' ACCOST. TILE 2 1 FINISH MATERIALS LIST (REFER TO DIRECTORY OF MANUFACTURERS AND SUPPL..IERS) EXTERIOR T_NTERIOR EXTERIOR CONCRETE WALKS (STANDARD) :9 QUARRY TILE 1 s DINING ROOM QUARRY STREAM SERIES - 1-28' 'RAWHIDE' CONCRETE BROOM FINISH SURFACE FLOOR TILES BY AMERICAN OLEAN 'WITH COVE BASE EXTERIOR PAVER TILE (OPTIONAL) WITH BROWN ACID -RESISTANT GROUT. 4'XB'X1/2' W-200 'DESERT SAND' (WIRE CUT) SUNSHINE PAVERS (COLOR - 'L-48' 'SAGEBRUSH TAN' IS AN APPROVED ALTERNATE.) AS MANUFACTURED BY FLORIDA BRICK & CLAY COMPANY INC. OR OR '56 'APALOOSA' STRATA QUARRY TILE BY SUMITVILLE 4'XB'X1/2' '105 'BUCKSKIN' IRON ROCK CERAMIC TILE AS WITH COVE BASE AND BROWN ACID RESISTANT GROUT. MANUFACTURED BY METROPOLITAN CERAMICS. OO OR '54 'DRIFTWOOD' STRATA QUARRY TILE BY SLWITVILLE 4'X8'X1/2' '96 'WILLIAMSBURG' (WIRE-CLJT) OWE TOWN QUARRY AS WITH COVE BASE AND BROWN ACID -RESISTANT GROUT. MANUFACTURED BY SUMMITVIH E TILES INC. VERIFY SPECIFIC TILE SIZE W/ OWNER. 4'XB'X1/2' '750 'CADET GRAY' AS MANUFACTURED BY PEE DEE CERAMICS. QUARRY TILE 2 KI TCHEN MORTAR, THIN SET METHOD DING LATICRETE '4237 WITH ONE PART 6'X6'X1/2' 'C01-CANTON RED QUARRY TILE 'WITH ABRASIVE FINISH BY RICANACID- CLEAN TILE CO., WITH 5' HIGH COVE BASE AND FINE SAND AND ONE PART POTTLAND CEMENT. N BROWWN ACID-RESISTANTT GROUT. GROUT= LATICRETE 03701 GROUT AND MORTAR ADDITIVE WITH OR FACTORY PREPARED GROUT OR FIELD MIXED WITH TWO PARTS SAND 6'X6'X1/2' 'CONCOURSE' QUARRY TILE WITH ABRASIVE FINISH BY AND ONE PART CEMENT. COLOR OF GROUT: BROWN MID -STATE TILE CO., WITH 5' HIGH COVE BASE AND BROWN ACID -RESISTANT GROUT. NOTE: TILES SWILL BE LAID IN A BASKETWEAVE FIELD PATTERN OR AND ONE ROW STACK BOND BORDER AT BLDG. PERIMETER. 6'X6'X1/2' '10 SUMMITVILLE RED QUARRY TILE WITH ABRASIVE BRICK & MORTAR FINISH BY SU,MMITVILLE AND 5' HIGH COVE BASE AND 'HONEY DEN' PEP BLEND '13 ('WIRE CUT) BRICK AS MAN+UFACTI.RED BROWNACID-RESISTANT GROUT. OR BY ACME BRICK. OR 6'X8'X1/2' SUNSET RED QUARRY TILE 'WITH ABRASIVE FINISH BY '481-483 (WIRE CUT) BRICK AS MANUFACTURED BY BELDEN BRICK. UNIVERSAL TILE CO. W/ 5' HIGH BASE & BROWN ACID -RESISTANT GROUT. OR CERAMIC TILE 1 RESTROOMS WINTER WHITE AND '1-32' (WIRE CUT) BRICKS AS MANUFACTURED BY 4 3/8'x4 3/8'xl/4' BRIGHT GLAZE 03 BONE CERAMIC TILE GLEN-GERY BRICK. BY FLORIDA TILE WITH WHITE ACID -RESISTANT GROAT ALL MORTAR FOR FACE BRICK TO BE COLORED BUFF OR 4 1/4'x4 1/4'x1/4' GLAZED 'D-135 ALVaU CERAMIC TILE DIAGONAL SIDING BY DAL -TILE CORP. 'W/ WHITE ACID -RESISTANT GROUT. OR 12'X16'-0'X1/2' DROPSIDE TEXTURED PRIMED 'SIPERSIDE 4 3/8'x4 3/8'xl/4' (LAZED 11108 ALMOND CERAMIC TILE LAP SIDING' AS MANUFACTURED BY MASONITE CORP. BY MID -STATE TILE CO, W/ 'WHITE ACID -RESISTANT GROUT. WOOD TRIM/FASCIA ACCENT BAND tt1 WOMEN'S RESTROOM CEDAR, GRADE 'B' SELECT SMOOTH TEXTURE. 4 3/8'x4 3/8'x1/4' CRYSTAL GLAZE 0683 ROSE CERAMIC TILE FIBERGLASS ROOF SHINGLES BY FLORIDA TILE on G.A.F.= TIMBERLINE - CEDAR BLEAR OR 4 1/4'X4 1/4'x1/4' CRYSTALTEX 41288 WILD ROSE CERAMIC TILE BY DAL -TILE CORP. CELOTEX= DIMENSIONAL III - WOOD TONE OR OR CERTAINTEED = INDEPENDENCE - RESAWN SHAKE 4 3/8'x4 3/8'x1/4' (LAZED 11334 SOFT ROSE CERAMIC TILE BY MID -STATE TILE CO. BARREL ROOF TILE ACCENT BAND 32 MEN'S RESTROOM GORY ROOF TILE - VANGUARD ROLL - FC-22. BARREL TILE TO BE INSTALLED ON 1X2 P.T. 4 3/8'x4 3/8'xl/4' CRYSTAL GLAZE 0667 REG&CY BLUE BATTENS, NOT DIRECTLY TO PLYWOOD SHEATHING. CERAMIC TILE BY MID -STATE TILE CO. SOFFIT PANELING OR 4'-0'X9'-0'X7/16' (GROOVES 4' O.C.) RUF-X PRIMED SIDING 4 1/4'x4 1/4'x1/4' CRYSTAL BLUE ISM-07 CERAMIC TILE `3940 AS MFRD. BY MASONITE CORP., COMMERCIAL DIVISION BY DAL -TILE CORP. OR OR A.P.A. SERIES 303-8-W 1/2' TEXTURE 1-11 SIDING, CEDAR OR FIR FACE, ROUGH -SAWN WITH G90OVES 4' O.C. 4 3/6'x4 3/8'x1/4' (LAZED $722 BRIGHT HERON CERAMIC TILE BY MID -STATE TILE CO. PAINTED/STAINED FINISHES FCR PAINT SELECTION AND SURFACES TO BE PAINTED, REFER TO SHEET A-2 EXTERIOR BUILDING ELEVATIONS. INTERIOR CERAMIC TILE 2 (OPTIONAL) KITCHEN 4 1/4'X4 1/4'X1/4' D-154 MEXICAN SAND CERAMIC TILE BY DAL -TILE CORP. W/ WHITE ACID -RESISTANT GROUT. OR 4 3/8'X4 3/8'X1/4' BRIGHT GLAZE 425 MEXICAN SAND CERAMIC TILE BY FLORIDA TILE WITH WHITE ACID -RESISTANT GROUT. OR 4 3/8'x4 3/8'x1/4' WATERCOLOR BRIGHTS SERIES 4144 MEXICAN SAND) CERAMIC TILE BY MID -STATE TILE CO. OR 4 1/4'X4 1/4'X1/4' BRIGHT GLAZED 'U-776 MEXICAN SAND CERAMIC TILE BY UNITED STATES TILE CO. WALL PANELING DINING ROOM MARLITE TONGUE & GROOVED DESIGN PLANKS -(TYPE AND CCLCR AS PER DECOR DRAWINGS.) KITCHEN/STORAGE & CREW AREA/OFFICE F.R.P. - MARLITE BRAND F.R.P. BY MARLITE ARCHITECTURAL. PRODUCTS. CCLCR 'P-106 BEIGE. OR GLASBORD-P F.R.P. PANEL BY KEILITE DIVISION OF DYROTECH INDUSTRIES INC. CCLCR= SOFT BEIGE 170. OR STRUCTOGLAS F.R.P. PANEL BY SEQUENTTIA, INC. COLOR: '1726 BEIGE. GYPSUM BOARD 1 5/8' TYPE 'X' GYPSUM BOARD. GYPSUM BOARD 2 5/6' WATER-RESISTANT TYPE 'X' GYPSUM BOARD. GYPSUM BOARD 3 1/2' THICK 'DUROCK' TILE BACKING BOARD TO 3 FEET HIGH AS MANUFACTURED BY U.S. GYPSUM COMPANY. OR 7/18' THICK 'WONDER BOARD' TO 3 FEET HIGH AS MANUF. BY O.E.I. CORP. AND 1/2' WATER- RESI STANT TYPE X' GYPSUM BOARD FROM 3 FEET HIGH TO CEILING. ACOUSTICAL TILE 1 DINING ROOM 24'X24'X5/8' MINATONE 'CORTEGA-8704A' TEGULAR LAYIN CEILING PANELS BY ARMSTRONG (FLAMESPREAD 0-25- ASTM E 84). TO BE LAID IN AN EXPOSED (WHITE) METAL 'T' GRID SUSPENSION SYST. BY CHICAGO METALLIC CORPORATION. OR 24'X24'X5/8' USG GYPSUM CEILING PANEL, AURATONE TYPE III, FORM 2 OMNI FISStRED SHADOWLINE ' 323 TO BE LAID IN USG INTERIORS EXPOSED (PREFINISHED WHITE) GRID SUSPENSION SYSTEM ACOUSTICAL TILE 2 KITCHEN U.S.G. GYPSUM CEILING PANEL, FIRECODE 'C' NONCOM0.)STIBLE GYPSUM CORE LAMINATED WITH WHITE 2 NIL VINYL COVERING. MOISTURE RESISTANT AND CCIPLETELY 'WASHABLE WITH STIPPLE DESIGN 'G259 1-1/2 HOUR RATED FLAME SPREAD • 15 FUEL CONTRIBUTED - 0 SMOKE DEVELOPED - 0. WOOD FINISHES OAK TRIM - UtFINISHED SELECT RED OAK IN SIZES AS SHOWN ON PLANS. CONTACT NATIONAL SlX'PLIER - WHITTELSEY WOOD PRODUCTS. PAINTED/STAINED FINISHES OAK (UNFINISHED)- TO BE FINISHED AS FOLLOWS: -SAND WOW -APPLY SANDING SEALER -SAND WOOD -APPLY 2 COATS POLYURETHANE FLOOR TILE INSTALLATION= GLEAN SLAB, REMOVE DUST, AND MECHANICALLY REMOVE CURING gAfU rD AND SEALERS TO INSURE PROPER BONDING OF THINSET. USE 'MULTIPLff'GSE' TYPE THINSET - MINIMUM. 4 1_ cf:� pow J c ISO 0 A rI C D(A _ DC D QL----j D L @ .1 CHCP�l� AC ESS Q DO D011 lD(_nl RECOMMENDED SEATING LAYOUT SCALE* 1/4"-1'-O" (SEATING CAPACIT`( = 80) ELEVATION 1 SCALE: 1/4' - 1'-0" tLL V A I WIN � SCALE 1/4' • 1'-0" HCP ASSISTANCE SIGN ni TI T\In FRONT VIEW DIVIDER WALL ELEVATION SCALE 1/2'=1'-O' ELEVATION A SCALE: 1/4' - 1'-O" SCALE: 1/4' - 1777C wvwiUl nAU o.v.1U 11101MLL. ELEVATION 5 E 1 1/2' RAILING W SECTION AT LOW DIVIDER WALL SCALE: 1 1/2"=1'-0" ELEVATION SCALE: 1/4" - 1'-0° 3 REFERENCE ONLY SEE DECOR PLANS FOR FINAL LAYOUT AND SPECIFICATIONS. SEATING AND DECOR SCHEDULE DESCRIPTION NOTE UMBER SEATING A BOOTHS OAK SIDES W/ FIBERGLASS SEAT (TEXT) & VINYL (GRADE C OR ABOVE) BACK PAD 24' SINGLE BOOTH WITH STEEL 1 24' DOUBLE BOOTH WITH STEEL 42' SINGLE BOOTH WITH STEEL 42' DOUBLE BOOTH WITH STEEL. EXPOSED END UNITS W/ FINISHED BACK 'Y/ STEEL BOOTHS OPTIONAL OAK SIDES W/ OAK SEATS & VINYL (GRADE C OR ABOVE) BACK PAD 24' SINGLE BOOTH WITH STEEL 24' DOUBLE BOOTH WITH STEEL 42' SINGLE BOOTH WITH STEEL 42' DCL,BLE BOOTH WITH STEEL EXPOSED END UNITS W/ FINISHED BACK W/ STEEL B CHAIRS FREESTANDING LOWENSTEIN STYLE 2760 NAT. FIN. W/ UPHOLSTERED SEAT (GRADE C OR ABOVE) OR APPROVED EQUAL 1 C BARSTOOLS TO MATCH CHAIRS 0 TABLE TOPS OAK -ROUTED EDGE OR WOOD GRAIN VINYL W/ PLASTIC LAMINATE INLAY 21' X 24' TABLE TOP 1 24' X 24' TABLE TOP 42' X 24' TABLE TO' 1 26' X 28' TABLE TOP 1 TABLE BASES GROUT IN SUPPCRTS FOR 24' TABLES 1 FOR 42' TABLES 1 FOR 28' X 28' 1 D ECOR E DIVIDER WALLS MARLITE W/ OAK TRIM & OAK FRAMED ETCHED GLASS W/ BRASS RAILS (PER SPECS) 1 DIVIDER WALL ADD-CN SCREEN & BRASS FOR SINGLE CCLNTER & GREENHOUSE DIVIDER DINING COUNTERS OAK -ROUTED EDGE W/ PLASTIC LAMINATE INLAY F FLOOR PLANTERS MARLITE W/ OAK TRIM & TILE ACCENT BOND IF REQUIRED FOR LIVE PLANTS 1 G TRASH UNITS PLASTIC LAMINATE W/ OAK TRIM SINGLE UNIT DOUBLE UNIT 1 H SERVICE COUNTER PLASTIC LAMINATE W/ OAK TRIM 1 I 1. QUEUEING SYSTEM OAK TOP RAIL W/ BRASS OR STEEL POSTS 1 2. WALLCOVERING COMMERCIAL GRADE/FIRE RETARDANT 2 3. POSTERS/ARTIFACTS PACKAGE 1 4. WALL SHELVES/WALL PLANTERS OAK AS REQUIRED 5. SIGNAGE RESTROOMS/KITCHEN BRASS OR UNIVERSAL 2 - RESTROOMS 1 1 OR 2 (AS REQ'D.) - KITCHEN 1 6. WINDOW VALANCES (OPTICN.) VINYL UPHOLSTERED VALANCE W/ 16' DROP FLAME RETARDANT 1 J HANGING PENDANT LIGHTS & WALL SCONCES 2 K CH ILING FANS 3 L BRASS PLANTERS HANQING OR FLOOR - W/ PLANTS 4 M MARLITE 3 N PLASTIC LAMINATE DOOR SPECIFIED BY DECOR SUPPLIER 3 0 JOAK MOLDING, TRIM & CHAIR RAIL 3 P DECORATIVE CERAMIC TILE (CPT) G.C. TO COORD. COLOR W/ DECOR SUPPLIER Q 1/4' THICK CLEAR MIRROR 1 SELF -SERVE DRINK UNIT - STAINLESS STEEL CAN ALSO BE PURCHASED FROM A K.E.S. PLASTIC LAMINATE & OAK TRIM (PER SPECS) 1 1 DRINK( SIGN - OAK FRAME/PLEX MIRROR (OPT) NOTES: THIS IS A TYPICAL SCHEDULE. ACTUAL WORKING S(HEDU-E AND SPECIFICATIONS. TO BE PROVIDED BY DECOR SUPPLIER. NOTEt 1. FURNISHED AND INSTALLED BY DECOR SUPPLIER (OR REGION TO PROVIDE INSTALLATION). 2. FURNISHED BY DECOR SUPPLIER AND INJSTALLED BY GENERAL.. CONTRACTOR. 3. FURNISHED AND INSTALLED BY GENERAL. COUTRACTOR. 4. FURNISHED BY OWNER. �ceria�ia;Ks+usJSr�ris:42�r/�l.�lYfle%�fd®&.'k'art±�ta8&%r,Y�dSali�75!Dsok iids4A:sFJ�:P€5.st7r7,Yt'�iY�riti�4W� Y f O 7 M s t.. ., - ..... .._ lr rv' .+ '. L a '.. 1 .. .s<:. :.:: .- .... ♦: - .. .. t`'.tiF.i15' ' ¢ . L ... .., ...... ♦ _ f...... a d �. ,. s f.. .. }`.. ... .. .. _ is -... .tr - .. -...s> -.. :. ..,�. -:- .}.. r �c.. .... .. _. .. .�_ ,�,. J.9 ,. ..._ r ... .. ., _..t ,.... �. ,.:... ., , _ .. .. F a � p :•^,; .:. .., ., ,., u.... ,. e, x..-:, �t. .. rt. ,.. t s ,�+...n v.. ::s. a. y ,. ,.. Z._,. .. - s :a?. _'� v ...,. :� �. t,_ A. »� v c.. :R:esi 3'. -i>t ', ... r ,_. �.. .. .. _.. , S3. t d s- �:' . .. r . ...s .t m .., pp .., s' .. _..., . .,_ ,^ �. 5 .. ....,. �.�r +: , t} _.a. .. .,.. .d-.. �,tx.R .4. ,..�. 3.a ,f _. �.^, _ ..i <. ... �Jz-. _.a .z' §..a,_ t ... ,..,1 .. S_.� ... ,. ., ,...., rt �. .i .�..... �L .. i... i3 ., . r^..+ to f...¢ ...... .. � , , .. , , ,..r. � . . _, . ,. . . r~ � . 1 ..rt . :;..% . , ., x ,�_ [ art �,- ? . 4:. - ,. ,e-� .. �. ri.. .. .a. :, ! v r .t.. sU..n. .. .. -t!.. l ... ,. a, :t. _. .., t i r. 1 ,.fi., _ v .*i -. «..,.k.. ,_., ,..�. t. ,:h«+• .,.. .. .. -.k. r _�{.. vy. .. . yE.. A <v , 4 N .:P. r _e .• ,. ., $t .:. ... � . _.. ,. ry S +1'., .. A.. .. .. r.. ., .. _..' R' 'K...,. :rY.... c.. ., .... �. .a _4r.. ,P. ,�._s ,.� �. ..- ,. ,:.r �.-,..,..3a�, ... � ... _,. _ s.. �...� � r-�... ..i.t t .�3 M � :.;;,, r v r i........,..0 1rt.�k ._...._..�. .�... z.: .,,_ �....k r'-: ..:.�. �. t+...r a.. �_. 3 . _��. ..«r..,,...,.u�Y:'.a,r,..i.n. n r.�-,...a.:, €.. r._t' �. «.- ,�. vY �x-. .,..�.. r,t. � Y. i,: .r. E,r �:. .. .. _n..,.:... �: .. .. .. :.1�':vt7'.. .,.>,x.,. .,. _�'..,.y J 3.:...,-.,.,b,^,�,._1._.� .-.,..,;±e._t, `�`� ��. .. t.:i'«3.•t'.3.ca<.K. S's L: li. ,:kti 'r� r.y: }{ y-« �, 41 I LIMIT OF 1 FRONT BAY I ADDITION I 1 I 50o I a5o I � I A/C-1 i MATCH LINE -- I FOR ADDITIONAL NOTES AND DIMENSIONS, REFER TO SHEETS AC-1 & 2. STANDARD PARTIAL H.V.A.C. PLAN SCALE: 1/4"a1'-0" 1 LIMIT OF I FRONT BAY I ADDITION i I I I _ I 1 I 1 500 I 450 I I I I AC-1 12"0 AC-1 TO INCREASE TO 6 TON UNIT. I CONTR. TO COORD. I ELEC. CHANGES. 12"(D I 1 / I 1 I a5o - i F I � I �00 I FOR ADDITIONAL NOTES AND I DIMENSIONS, REFER TO 1 SHEETS AC-1A & 2. A/C-1 MATCH LINE—�� I 1 , ALT . PARTIAL H . V . A . C . PLAN PLENUM CUHB )- OhAI C. 1 /A"-11 n" 32x14 TO 18x14 SUPPLY RISER 8"(0 0 Rp I Q I 0 I 0 i I I 1 LnA i i I I i LIMIT OF FRONT BAY ADDITION I I — ALIGN CENTERLINE T-GRID WITH OF TRUSSES I 9'-1 ° A.F.F. 1 i I i MATCH LINE — I I I FOR ADDITIONAL NOTES, DIMENSIONS, AND CIRCUITING, REFER TO I SHEETS A-4, E-1, AND E-2. I I I I I PARTIAL REFLECTED CEILING PLAN SCALE: 1/4"=1'-O" �i Fj.coDC]oD J Cl,—,D n QI-JDODC� FROF I bNT BAY -� ADDITION MATCH �� Cl nn n �C7 gC7�JC� Q nn n ❑i 0 CI' Cl D Cl D FOR ADDITIONAL INFORMATION, NOTES, AND INTERIOR ELEVATIONS. SEE SHT. A ILI u a 0 D Cl [[d- D Cl D ❑❑ v �I RECOMMENDED PARTIAL SEATING LFlYOUf Qr'AI G r 1 /A ".1 ' _n" t Ann 'I QrATTKIP- r ADAPTTV - 'IA 1 / 1/2" 10' 13 FACE _ A-1�— OF PLYWD. r I I END COLUMN OF STD. z `D II I( I BUILDING MUST BE c; TURNED 90 ° 4X6 WOOD COLUMN 13 s-3 I I I I i I it I 1 II I� I I II I f i III I I o II I I I 1 0o I LIMIT OF FOR FOUNDATION INFORMATION, f ui I I I I FRONT BA`( ADDITIONAL NOTES AND DIMENSIONS, I ` _ LL I I I ADDITION SEE SHEETS S-1 AND A-1 . oCD I I o N W� °° rn CD MATCH LINE---i- ��5 I I a i II II I 1 � II 4X6 WOOD COLUMN I I i I I I 'o I B DLDING MUCOL OF STD. II I I BE TURNED 90° i N ' 1 f- *- CO A-6 o — — - - — — — — — — — — — I — — — — — — _ — — — — — — — — A11 SIM. 1 A21 1 O 1 ° 0 / 10'-0" V 10'-0" 6" 7 1/2" 10'-6" z 83'-4" (OUTSIDE FACE OF FOUNDATION WALL AND FACE OF BRICK TO FACE OF BRICK) °o PARTIAL FLOOR & FOUNDATION PLAN SCALE: 1/4"=1'-0" ADDITIONAL AREA - 388.5 SO. FT. vn, nvvl, tv,v SCALE: 1/4" - 1'-0" F /1rl i-r1L U fn 1 V L- I I InU LLL V /-1 11 UI V I REFER TO SHEET A-2. rrrA,C. AJA° - 1'-n" 1 . 1 . x F. F / O.C.}. m s. I FGT--Tl I I ADDITIONAL 2X4 WOOD BRACING ( BOTTOM FHORD ) 1 I 1 ? 1 I EL12'-9" A.F.F. I TOP OF USS o H.P. I I ADDITIONAL 2X4 WOOD BRACING (BOTTOM CHORD) I LIMIT OF i FRONT BAY I ADDITION I 1 I 1 d I I _. w MATCH LINE ADDITIONAL 2X4 WOOD BRACING ( BOTTOM C HORD ) I 1 — I I i " S-3 EL. 11 -6 1/2 FOR ADDITIONAL NOTES AND DIMENSIONS, SEE SHEET S-2 } TOP OF GIRDER "!RUBS U CL 0o ' -a (on , (n�i7 4� � PAR -DIAL F ROO FRAMING PLAN Q A('7� `-� (n 'vQ��� o SCALE: 1/4"=1'-0"-oc3m'c�u. Q COUK Jai AIR BALANCE SCHEDULE LNIT W . RET" AIR OUTSIDE AIR EXHAUST AIR MAKE -LP AIR A/C-1 1715 625 A/C-2 1376 625 A/C-3 1775 625 A/C-4 1715 625 EF-1 1000 300 EF-2 1350 EF-3 360 TOTALS L 6700 CF11 •2600 CF61 -2700 CF11 •300 CF11 BUILDING POSITIVE PRESSURE - •100 CF11 83'-4" 10'-6" 72'-10" 61'-8 1/2" KEY PLAN N.T.S. mli III k' js1 Zrsr r . . ' - .. r :. ,.rd ^" a.."• .K+" RC ` ' _T' 9 .� `�'.. P�• p$," t� �t #,�!"'i.55�J '{yf $ �`-: �` t H `g+ KITCHEN EQUIPMENT SCHEDULE I-. ►'- o DESCRIPTION NOTES ELECTRICAL PLUMBING REMARKS A B C VOLT PH HP KW AMP DRN HW CW GAS BTUH x1000 1I J SELF -SERVE DRINK COU'lTER X 11 ' -0LCtNG 1A 2 1 ICE DISPENSER X 115 l 0.35 3.0 1B 2 SODA DISPENSER X 115 1 0.15 1.3 PART OF DRINK SYSTEM (ITEM •26) 1C 1 COFFEE MAKER X 208 1 6.3 29.0 1/4' 1D 1 ICE TEA DISPENSER _ X lE 1� SELF -SERVE CONDIMENT DISPENSER X IF I 1 STRAY DISPEiiJSER X 2 1 SERVICE CCUNTER X SEE DETAILS THIS SHEET. 2A 1 CUP DISPENSER 2B 7 CASH DRAWER X PC LOT PKG.-WIRE SHELVING X 3 1' DRIVE-THRU BEVERAGE COUNTER X 2'-10' X 3'-0' 3A 1 AUXILIARY ICE AND BEVERAGE STATION x_ 3/4' 3$ 1 SODA DISPENSER X 116 1 0.15 1.3 PART OF DRINKS SYSTEM (ITEM •26) 3C 1 COFFEE MAKER X 120 11 1 2.2 18.3 1/4' 30 1 ICE TEA DISPENSER X 3E 1 CUP DISPENSER X 3F 1 LID DISPENSER }( 3G 1 1 UDERCOUNTE_R REFRIGERATOR �{ 116 1 1/4 0.52 4.5 3H LOT PKG.-WIRE SHELVING X 3I 1 S/S SERVICE CHASE (12 1/8'x6 1/8') X SEE MOTE 86 THIS SHEET 3J 1 HOT CHOCOLATE MACHINE (OPTIONAL) X 115 1 1.7 15 114' 4 1 D/T P.O.S. / EXPEDITING COUNTER X I I I I i 3'-3' X 3'-3' 4A 2 CUP DISPENSER (OPTIONAL) X 48 1 CASH DRAWER x 4C LOT PKG.-DRY STORAGE SHELVING X 40 1 TICKET HOLDER X 5 1 SHAKE MACHINE X 208 3 2-1FP 2.5 12.0 1/2' 1/2' DRAIN TO F.S. UNDER ICE MACHINE 8 1 ICE MACHINE X 208 1 1 1/2 3.9 119.0 1/2' 6A 1 ICE BIN X 3/4' 7 1 3-COMP. SINK X 2' 1/2' 1/2° W/ 24' DRAINBOARDS 8 1 ICASHIER STAND X 3/4' PLASTIC LAM. PLYWD COUNTERTOP - 36'AFF 8A OT PKG.-WIRE SHELVING x8B 1 ICASH DRAPER X KEY OPERATED 8C 1 1DRIVE THRU EXPEDITING COUNTER X 10'x24'x3/4' PLASTIC LAM. PLYWD. g 1 SANDWICH HOLDING STATION X PRE -WIRED LOAD CENTER 9A 2 SANDWICH CHUTES X 115 1 1.31 11.4 10 1 ERGONOMIC PREP. BOARD / MAIN PREP. BOARD X CONECT TO LOAD CENTER IN ITEM •9 10A 4 MICROWAVE OVEN) X 208 1 3.2 15.4 108 1 UD ERCOUNTER REFRIGERATOR (OPTIONAL) X 115 1 1/4 0.62 4.5 10C 1 SS SERVICE CHASES X SEE NOTE •6 THIS SHEET 10D 1 TOPPINGS WARMER X 115 1 0.5 1 4.35 11 1 STEAMER X 208 1 4.96 23.8 CONNECT TO LOAD CENTER IN ITEM '9 12 1 BROILER X 208 1 3.6 17.5 3/4' 96 12A 1 BROILER STAND X 128 1 MEAT FREEZER X 116 1 1/4 1.04 4.7 13 1 BROILER HOOD X I FOR DETAILS AND SPECS SEE SHT. EO-2 14 1 FRY HOLDING STATION X 115 1 0.5 4.3 14A 1 HEAT LAMP ASSEMBLY X 115 1 1.5 13.0 15 4 DEEP FAT FRYER X 120 1 0.8 7.0 3/4' 122 15A 1 BUILT-IN FILTER X 120 1 0.9 6.0 15B 3 FRY COMPUTER X 115 1 1 0.04 0.35 16 1 FRIES THAW RACK X 17 1 FRYER HOOD X FOR DETAILS ANJD SPECS SEE SETT. EQ-2 18 1 SPECIALTY SANDWICH TABLE X SERVICE CHASE - OPTIONAL. 18A 1 HOLDING CABINET X 115 1 1.13 9.6 18BI 1 I BUN GRILL X 115 1 1.5 12.5 18C 2 REACH -IN FREEZER X 115 1 1/4 0.7 6.3 180 1 CHICKEN TENDER FEAT LAKE' x 115 1 0.9 8.0 18E 1 S/S SERVICE CHASE (3'x8') X SEE NOTE $8 THIS SHEET 18F 1 MICROWAVE OVEN (OPTIONAL) X 1208 1 3.2 16.4 180 2 MJL.TI-PRODUCT HOLDING UNIT X 115 1 0.72 6.25 POWER IDENJTIFIED IS PER UNIT 19 1 1CROISSANT TOASTER X 208 1 - 4.22 20.3 19A 1 IMOBILE TABLE X I I 3'-o'x2'-2' 20 1 JBISCUIT OVEN (OPTIONAL) X 208 1 1/4 6.6 4-12-16 21 1 BISCUIT WARMER (OPTIONAL) X 1115 1 0.5 4.3 22 1 WORK TABLE (OPTIONAL.) X 4'-0'x2'-6' 23 1 'NO HANDS' SINK X 1 1 1/2' 1/2' 1/2' SEE DETAIL SHEET 24 1 VEGETABLE PREP SINK X 1 2' 1/2' 1/2' W/ 24' DRAINJBOARD 24A 1 GARBAGE DISPOSAL (OPTIONAL) X 206 1 4.0 19.2 25 1 VEGETABLE CUTTER X 1115 1 1/3 0.6 5.7 26 1 DRINK SYSTEM X 208 1 4.5 22.0 1/2' 1/2' SEE NOTE 08 THIS SHEET 27 1 BAG -IN -BOX SYRUP RACK X RUN HOSES ABOVE SUSPENDED CEILING 28 LOT PKG.-DRY STORAGE SHFIVINJG X STATIONARY & MOVABLE (SEE PLAN) 29 1 WALK-IN REFRIGERATOR / FREEZER X SEE NOTE 13 THIS SHEET 29A 1 EVAPORATOR SYSTEM / REMOTE CONDENSING UNIT X 29B LOT PKG.- REFRIGERATOR SHELVING x 29C LOT PKG.-FREEZER SHELVINJG X 30 1 BREAKFAST GRILL X 116 1 0.33 1 2.0 3/4' 82.5 31 0 DIVIDER PANEL. X 32 2 CONDIMENT PAN HOLDER X MOUNT 2' ABOVE SINK BACKSPLASH 33 0 WAREWASHER (OPTIONAL) X 208 1 1 7.7 36 1/2' 34 1 THAW UJIT(OPTIONAL) X 115 1 0.68 4.9 35 1 BUN RACK X 36 1 IREFRIGERATED DISPENSING UNIT X 115 1 0.68 4.9 40 5 P.O.S. DEVICE X 116 1 1.2 ISOLATED GROUND CIRCUIT 40A 2 P.O.S. PRINTER DEVICE X 115 1 1.2 ISOLATED GROUND CIRCUIT 41 1 MEND BOATO X 115 1 7.8 42 1 STOCK LEVEL SYSTEM X 115 1 0.35 42A 1 STOCK LEVEL LIGHT CONTROL X 43 1 SPEED OF SERVICE TIMER X 115 1 1.2 43A 1 SPEED OF SERVICE PRINTER X 116 1 1.2 44 2 FIRE PROTECTION SYSTEM Y/ REMOTE PULLS X SEE SHT. EQ-2 FOR DETAILS AND SPECS. 46 1 ABC FIRE EXTINGUISHER X 10 LBS MIN. 46 1 BC FIRE EXTINGUISHER X 10 LBS MIN. 47 1 OFFICE COUNTER TOP }( 3/4' PLASTIC LAMINATE PLYWOOD - 34' HIGH 48 1 CREW R0061 CCLNTFA TOP X 314' PLASTIC LAMINATE PLYWOOD - 30' HIGH 49 1 CREW TRAINING MODULE CABINJET X MTG. HT. 20' MIN. ABOVE CREW ROOM COUNTERTOP 50 1 SAFE X 61 1 FILE CABINET X 62 1 TIME CLOCK xi 115 1 5.0 63 12 LOCKER x - - 54 0 IVIDEO DRIVE-THRU SYSTEM X 55 1 IWATER FILTER SYSTEM X - 3/4' SEE SHT. P-2 FOR MORE INFORMATION 68 2 WALL MOUNTED SHELVING >{ - A MOUNT 90' A.F.F. UNLESS OTHERWISE INDICATED 57 1 C%RJTER SHELVING COMPONENT SET (UNDER DESK) _ _ 8.4 - -„ -- SUPPLIED BY P.O.S. SUPPLIER QUICK DISCONNECT 58 0 VERTICAL CONTACT TOASTER X 208 1.16T 59 0 BUJ HOLDING CABINET X - 120 _ -- 20 - ` 60 0 REFRIGERATED CONDIMENT UNIT X 120 120 LEGEND ® SAFE WASTE FLOOR SINK SERVICE CHASE ®EXAUST/SUPPLY PLENUMS - - - OPTIONAL NOTES: 1 . COLUklN 'A' = EQUIPMEINT TO BE FURNISHED & INSTALLED BY EQUIPMENT/DECOR SUPPLIER. '(SEE NOTE 2) COLUMN 'B't EQUIPMENJT TO BE FURNISHED BY EQUIPMENT/DECOR SUPPLIER AND INSTALLED BY GENERAL CONTRACTOR. CCLUIaJ 'C'. EQUIPMENJT TO BE FURNISHED AND INSTALLED BY G.C. 2. GENERAL CONTRACTOR TO COORDINATE WORK AND PROVIDE FINAL MECH. & ELEC. HOCK -UPS TO ALL EQUIPMENT AS REQUIRED. EQUIPMeTT SUPPLIERS TO MATCH THESE PLANS FOR FLOOR SINK AND/OR DRAIN LOCATIONS. 3. GENNERAL. CONTRACTOR TO VERIFY W.I.B. SIZE MWJU ACTURER, & POWER REQUIREMENTS. 4. REFER TO APPROVED EQUIPMENT INDEX FOR APPROVED SUPPLIERS. 5. CONTRACTOR SHALL PROVIDE SOLID WOOD BLOCKING BETWEEN STUDS FOR SUPPORT OF ALL WALL HUNG FIXTURES. WATER LINES, SHELVES, ETC. 6. RUN ELECTRICAL, GAS, AND WATER LINES THRU CHASES FROM CEILING. 7. ALL DIV&ISIONJS ARE TO BE VERIFIED BEFORE EQUIPMENT FABRICATION. 8. RUN SYRUP LINES ABOVE CEILING TO DRINKS STATION. 14' - WALL PROVIDE SHELF SUPPORTS AT EACH END AND AT MIDSPAN (TYP. 3 SUPPORTS PER SHELF) WALL MOUNTED SHELVING SCALE: 1/2"-1'^0"^" SECTION SCALE: 1 1/2"=1'-0" u, NUIE d G.C. TO VERIFY LENGTH AND WIDTH OF UU) ALL COUNTERS W/FIELD MEASUREMENTS. 0 �- --le - 0 z z z o 8 STUD PROVIDE 2-1/4"X3". LAG BOLTS PER SUPPORT (TYP.) PROVIDE 2X6 BLOCKING BETWEEN STUDS (TYP) cn m TRAFFIC GUIDANCE SYSTEM NG SEPARATOR -AMINATE �P (BY DECOR MFR.) 1 X2 WD . MOULDING 3/4" PLASTIC LAM. PLYWOOD SERVICE COUNTER (BY DECOR SUPPLIER) 2X4 STUD BLOCKING CHASE FOR P.O.S. CABLE 2X4 BLOCKING 2X4 WD. STUD WALL STUDS o 16' O.C. FRP OVER 5/8" GYP. BD. INTERIOR FINISH (SEE INT. DECOR DWGS. FOR FINISHES) )P SHELF ONLY f OFFICE. 14' PLYWD W/ PLASTIC kMINATE FIN. AT EXPOSED JRFACES. 2'-6" O.C. 12-2X4 WD. STUDS (ONE AT EACH END.) 2' 0" AT D/T AND CREW ROOM PROVIDE C 0 METAL BRACING o MIDPT. OR AS REO'D. Lu `_ IN OFFICE PROVIDE METAL BRACING 26" 3` FROM END COVERING COMPUTER SHELVING COMPONENT SET. o 'F 3/4' PLASTIC LAMINATED CI n, PLYWOOD SHELF TO MATCH DECOR (SUPPLIED AND INSTALLED BY GEN. CONTR.) CONT . 2X 4 WD . BLOCKING TO FIN. FLOOR SECURED TO WALL SECTION AT_COUNTER �OP ANDIDET EXPEDITING COUNTER 1 30 " 3C OF COLUMN OR WALL 4 (W/ 10"X16" EXPEDITING SHELF) 43 32 TT IF V slim .; 6A �4 -8" 7 31 3A,B •40A 4A,B,C,D = _ 3E , F 56 (30 "X 14 ") I � I BUNS I - - -� L - .J -'12'-10 1/2" 3'-8" r - -' " 36 I� 42A 3 1 18' +< 2'-10" -F 6'-8' f- 3' 5' 2'-g" MIL- 3G 12A8 J K I i14 f l 1/2" 7 40A 9A r I zs I - 3 -6 1g I BUNS I -g" , 4'-6" L = O 3'-4" co ' OA'B' I 14 m18E C� 14,_ - 19A C 1 -- - 53 c� I II I II � I I� 24" it 48" f ,- HCPi ACCESS II II i0A I I 18G 30 ' 46 16 ' 56 (24"X14") r 51 I l \ 43A I J TOP SHELFI MOUNT 78" AFF nl� 57 29C � 29A r -i 20'-6 1/2" 17'-10 296 I I L J ELECTRICAL PANELS 49 I 4 R 1 S 25 -50 I / \ DI 2a 24A C\j __ . _ i 11 II EOUIf'IvIFNT LAYOUT PLAN & SCHEDULE SCALE: 1/4"-1'-0" 19'-4" III 28 II I N 4 5,-g" ti r----1 r----1 r---� r - - - -1 r I I I ( Pk I I P.O.S P.O.S I ' I i ' I I P.O.S I �, r I ' I I TER 1 I I I L - - - J L - - - J I I I L L - - - J I I PROMOTIONAL D I SPLAY w �--- AREA UNDERCOUNTER REFRIGERATOR r UNDERCOUNTER FREEZER PLAN VIEW SERVING COUNTER SCALE: 1/2"•1'-O' 2'-6" 1 '-6" - I P.D.S. I L COMPUTER (TYP) 3'-6' 8" 3'-0' 3'-6" ELEVATION A SCALE: 1/2"=1'-0" STAGING AREA FOR: BREAKFAST CONDIMENT 1 SALAD PLATES & LIDS EQ-1 DRINKS LID S(SM.LG.) FORKS,KNIVES,LINED TRAYS. 19'-4° I 3'-0' 8'-10" EQUAL - EQUAL -- 36" r - - 5 _9" P.O.S. I 1PRINTER CASH - -� DRAWER REACH -IN UNDERCOUNTER FREEZER L CUP DISPENSER REFRIGERATOR C NDIMENT D SPENSER 3'-6°--2'-6'---2'-6'-1'-p",, 2,_6 2" 52 BULK CO2 Pl d rye '- � , x , . �,• 6� . JL, 4 v: • • T �. 55 e,r: r;iY v D r 18 GA. FURNISHf & INSTAI CONTRAC 2X WOOD MENU BOARD 7"X7' ACCESS PANEL TOP OF i HOOD FIN. FL T.O.S. . 'aw r... .,o �...v�. .tom.: �,.. � sr,als+? �. +'�'.eX,* ..s+eF,,.�. y� . ..•.�'.,.:�. h"a:.°"iti .�rS�: s;':i`% �.ss�r.r . ?_.7".._ ifCS:�; 4"x9" OPEN'G. FOR GAS LINE AND COMPUTER CABLE. A EQ-2 STAINLESS STEEL DUCT ENCLOSURE (36°) FRYER HOOD PLAN (6 BANK) SCALE: 3/4"=1'-0' 4---- CTR.LINE nF n1 ir.T FRYER HOOD SECTION SCALE: 3/4'-1'-0' CALCULATIONS BROILER HOOD SUPPORT 162.50 28 " 28 ° u n n WEIGHT OF HOOD: 650 LBS./4 HANGERS -162.5 LBS./R00 M-1950 IN.LBS. REO'D S- 1950/20,000=.10 IN. 3 S FURN.BY 2X2X3/16 =.19 IN 3 DUCT VELOCITIES BROILER HOOD: B.K. (EXHAUST) SPECS = 1000 CFM DUCT VELOCITY 1000 - 1600 FPM (9 X 10) 144 FRYER HOOD: B.K. (EXHAUST) SPECS = 1300 CFM DUCT VELOCITY = (9 X�13 5) = 1600 FPM 144 IAUST FAN I'D ACCESS OPENING I GASKETED COVER. )VIDE VENTED COVER z _Y WHEN REQ ' D BY � ,AL CODES. DF CURB 'X' GYP. BD. RATED ENCLOSURE. ;OUST.TILE _G . AL AREA TIGHT SOUND DUCT W/ LAYERS TYPE X 'P. BD. (TYP. ) S DUCT ENCLOSURE IYER HOOD 18 GA.S/S) EXHAUST FAN- - SUPPLY DUCT _ INTAKE N 2 LAYERS 5/8' TYPE "X" GYP". BD. ( TYP .) 1 HR . FIRE RATED ENCLOSURE FIRE DAMPER W/ U.L. LISTED FUSIBLE LINK (280') ACOUST.TILE CLG. BROILER HOOD (18 GA. S/S) 4'-0' --- (48") BROILER HOOD PLAN SCALE: 3/4'=1'-0' CTR.LINE OF DUCT �` I i CL AR 6 96"- MIN. T BROILER HOOD SECTION SCALE = 3/4'-1'-0' BURGER KING APPROVED HOODS SCHEDULE CONTAINS ITEMS NOT USED IN THIS BUILDING. CONTRACTOR TO VERIFY REQUIRED FOODS AND SIZES WITH SHEET EQ-1. MANUFACTURER BROILER MODEL NO. FRYER REMARKS MODEL NO. GAYLORD EAST CORP. 37 VREELAND RD. FLORHAM PARK, N.J. CGX-BOL-MA-ID-BK W. CGX-AB-3-BBC U.L." MH 13522 ICBU- 2064 BOCA- 084-24 NlFPA- 96 78' CGX-AB-4-BK 94' CGX-AB-5-BK 108, CGX-AB-6-BK HOOD NOTES: 1- ALL SEAMS AND JOINTS OF HOODSSHALL HAVE A LIQUID TIGHT CCNTINUCRJS EXTERNAL WELD.EXHAUST DUCTS SHALL HAVE AT LEAST 18 INCH CLEARANCE TO COMBUSTIBLE MATERIAL UNLESS PROTECTED FOR LESSER CLEARANCES WITH APPENDIX 'A' OF WPA-96-1984. ALL EXTERIOR DUCTS,EXCEPT STAINd FSS,TO BE PROTECTED BY PAINT OR OTHER SUITABLE WEATHER COATING. 2- FILTERS: TO BE U.L.CLASSIFIED GREASE FILTERS. 3- A PRE-ENGINEERED ANSUL R-102(WET)FIRE EXTINGUISHING SYSTEM MUST BE PROVIDED W/BOTH AUTOMATIC & MANUAL ACTUATION OF THE SYSTEM.MANUAL STATION SHALL BE ILKUffED NOT LESS THAN 4'-B" AND NOT MORE THAN 5' FROM FLOM AND SHALL BE CONVENIENTLY LOCATED IN THE PATH OF EXIT. 4- THE OPERATION OF THE EXTINGUISHING SYSTEM SHALL AUTOMATICALLY SNIT OFF ALL SUPPLY TO GAS OR ELECTRICAL OPERATED EQUIPMENT LOCATED UNDER THE HOOD. 5- EXHAUST FANS TO BE INTERLOCKED WITH ELECTRICAL CONfTACTCRS AND/OR ELECTRICALLY OPERATED SAFETY VALVE FOR GAS OPERATED APPLIANCE. 6- GENERAL CONTRACTOR AND/OR HVAC SUBCONTRACTOR IS RESPONSIBLE FOR MEETING ALL LOCAL HOOD/SHAFT INSTALLATION REQUIREMENTS AND THE WAC SUBCONTRACTOR IS RESPONSIBLE FOR ALL REQUIRED MECkANICAL PERMITS. 9"x10" EXH. DUCT 18 GA. S/S FURNISHED BY HOOD WAJF. & INSTALLED BY MECHANICAL CONTRACTOR. - REO'D ACCESS OPENING W/ GASKETED COVER. PROV. VENTED COVER ONLY WHEN REO'D BY LOCAL CODES. 2"X2"X3/16" _ SUPPORTING ANGLE SECURED TO 2'X2"X3/1 " STL. ANGLES BY G.C. HANGING BRACKET IN. FLR. r-T.O.S. N N i BY G.0 HANGIr & ROD FIRE PROTECT ION NOTES 1. N1 ET IDSM PIPE ` BE UflM PLATED. 2. ALL 1/2' & 3/4' FITTINGS SHALL BE WATERPROOF. 3. EACH HOW SHALL HAVE A SEPEERATE ANa.I R-102 (LIQUID CHEMICAL) FIRE EXTINGUISHING SYSTEM. EACH SYSTEM SHALL WORK INDEPENDENTLY. 4. FOR N A&R CF FIRE B(TINWISHING SYS104 SEE SHT.EO-1. 5. THE INSTALLATION AND OPERATION OF THE AUTO. FIRE PROTECTION SYS. SHALL BE CHECKED AND APPROVED BY RE LOCAL FIRE DEPARTMENT HAVING LRISDICTION. 6. ALL EQUIPMENT AND ITS INSTALLATICH SHALL BE AS PER WPA-96 AND LOCAL CODES. 7. INSTALLATION TO BE COORDINATED W/HOOD mFR. TO DETECTOR BRACKET W/ 500'F PREVENT SYSTEM'S INTERFERENCE WITH OPERATION AND PEFORMANCE OF VENTILATORS. FUSIBLE LINK GLOBE P/N.3236 OR EQUIV.PROVIDED BY HOOD B. FIRE PROTECTION SYS. CONTR. TO FURNISH & INSTALL TWO PRE-PRINTED PLASTIC FACED PLC PLATES W/ 1/2' MANUFACTURER & INSTALLED BY HIGH LETTERING. PLATES SHALL BE ADHESIVE APPLIED LIQUID -CHEMICAL CONTRACTOR. TO 'PALL & MOUNTED DIRECTLY BELOW REMOTE PULLS AND LABELRESPECTIVED ASAND 'FRYER' FOR THEIR ACCESS PANEL ` OPERATION.'BROILER' / 9. THE PRE -PIPED HOODS ALL COME COMPLETE WITH ALL DUCT NOZZLE ( 90OF T�E FIRE F4NOZZLES 9,0 BLOW -OFF CAPS, DETECTOR WW1 500' FUSIBLE INK AND POLYSHED 1 /2" D IA. LINE FROM CHROME -PLATED SCHEDULE-40 PIPES & FITTINGS. FUSIBLE LINK TERMINATIONS FOR SUPPLY & DETECTION LINE SHALL EXTEND 1' ABOVE HOOD FOR FINAL CCftfCTICNS BY FIRE PROTECTION SYSTEM CONTRACTOR. B OF 3/8" SUPPLY LINE TO � �� � I( F� 10. ACCESSORIES SUPPLIED BY THE FIRE PROTECTION LIQUID CHEMICAL TANK SYSTEM CONTRACTOR - EACH SYSTEM SHALL INCLUDE, (1) 4 U.. AUTObAN REGULATED RELEASE SYSTEM ASSEMBLY - P/N.71825 (1)PRE-PRINTED ADHESIVE BACKED NAMEPLATES PLENUM NOZZLE-� \� / (BROILER kD FRYER) (OREMOTE MANUAL PULL STATION- P/N.4835 (1)SNAP-ACTION SWITCH ASSEMBLY -P/N 15549 BROILER NOZZLES \ / ELECTR. AND PLU1,1B. CONTR. TO INSTALL AND/OR MAKE FINAL_ C:CaECTION TO ACCESSORIES AS REQUIRED. 11. PLUaB. CCNTR. TO FURNISH & INSTALL MECHANICAL GAS SHUT-CFF VALVES FOR FIRE PROTECTION SYS. VALVES CAN BE OBTAINED FROM THE FIRE PROTECTION SYSTEM SUPPLIER. ANISUL P/N - 55607 - 1 112'. HANGING BRACKET W BROILER HOOD ISOMETRIC NOT TO SCALE BROILER HOOD ELEVATION SCALE: 3/4'-1'-0' NOTE: THESE HOODS COME PRE -PIPED BY HOOD MANUFACTURER AS SHOWN BY HOOD MANUFACTURER ._.._--.----_...,-----_,._..- BY CONTRACTOR 1 /2"(V LINE FROM FUSIBLE LINK DETECTOR BRACKET W/ 500' F �� 3/8' LINE TO LIQUID FUSIBLE LINK GLOBE P/N 3236 '' T CHEMICAL TANK OR EQUIVALENT PROV . BY HOOD MANUFACTURER & INSTALLED BY ' FIRE EQUIPMENT SUPPLIER. �M ACCESS PANEL PLENUM NOZZLE DUCT NOZZLE NOZZLES (6) REO'D.-6 BANK HOOD (5) REO'D.-5 BANK HOOD'=��\ ' (4) REO'D.-4 BANK HOOD (3) REO'D.-3 BANK HODD VERIF`( HOOD SIZE WITH EQUIPMENT LAYOUT SHT. EQ-1. FRYER HOOD ISOMETRIC NOT TO SCALE TO FAN RELAY PANEL (SEE WIRING DIAGRAM 4X4 JUNCTION BOX TO GAS VALVE (TYPICAL FOR 2) TO DETECTION LINE OF HOOD (FUSIBLE LINK) (TYPICAL FOR 2 ) 1/2' CONDUIT CEILING AT 8'-6" TO MANUAL REMOTE PULL ,,,, }I ,, ( TYPICAL FOR 2) II II Till �-=- II I! r I111'�-=/� FJUL1LWL LJLUIl I f I I I { I TO SUPPLY LINE OF I I I I( I I I HOOD (TYP.FOR 2) I I I I I I L.-_-.J }- L__- J I I I I I I i I I ( I AGENT TANK 4" EDGE OF PARTITION STUD ( TYP ) II I I RECESSED REMOTE CABLE PULLS 40 COVERS BY I I LIQUID CHEM.CONTRACTOR I RECESSED 4 "X1 1/2' NOTE: ' OCTAGONAL J-BOX co 'o I I I #5415-1 /2 " BY ELEC . SHOWN IS PROTEANSULCTION R-102 8' —# 4 CONTRACTOR.ORIENTATION FIRE PROTECTION SYST OF MOUNTING SCREWS TO TO FIN. I I BE COMPATIBLE: W/REMOTE FLOOR , CABLE PULL COVER PLATE. TYPICAL LIOUID CHEMICAL SYSTEM SCALE 1"=1'-0' YM �y i' r c x*: .r AIR VOLUME: 20 - EXHAUST FROM SPACE- I00 ACFM EXH/SUP. INDUCED SUPPLY: .300 ACFM _ TOTAL E1(HAUST: 1000 ACFM 14 VEN T. SP: 1.50' 6 d IINSTALLATIONINSTRUC TION, 4 12 2 1/2 ! - -� ( L t. Hang ventilator at 6'-5' front Finish ed he�J floor to front lower edge of ventilator at Inlet end. (Refer to sheet 1) NOTE: IAake -- - R r GAYLORD---.- sure that the ventilator is positioned to align with the broiler ROOF CURB B GA LO D- 3 as illustrated on sheet I. - 10 FUSE LINK MFR. SEE SHT 2 FOR `� 4 ' - INLE I ' 48 _�--- 'BIRD SCREEN_ 2 Install Root Curb - IMPOR"tArJT Be sure to position curb So DE (AILS.' that the opening in the side for the supply inlet faces in the 28 sawn; direction as the ou^tiet end of the broiler - CHEMICAL INLEI ACCESS i Slide supply duct dC'trn through roof curb and angle it into Z ;apply duct collar. Push supply duct inlet through the '7' 1 ► ° r r opening in the side of the curb. ; :OTE. To accortirdate ID h ::W NOZZLE oos building con'5gurattons, the duct is ap plioxirnately 6' ~s'% N --- — agar than norrrra..j r quj,,c-J. ri.:, eng:h as necessary. 1 ' 4 SUPPLY U PLAN VIEW EXHAUST DUCT BY GA`t'!ORD MFR. — SUPPLY DUCT BY GAYLORD MFR. INLET - „ :�? ex-aust duct it J j 1 C'-.r:, aria c o �. Si Q tX vT HPF r _ _� G .r = U) I EXHAUST DUCT -\, IRE DAMPER PER NFPA PIPE 9 -.10 10" X TO ID, DUCT MUST BE FULLY 'MELDED 96 REQUIREMENTS pp ?nNC� PLENUM F- _ 0tig 1000 CFM TO DUCT COLLAR.' / 1/2- FLANGE NOZZLE y E-+M Q ! SUPPLY DUCT DUCT 14' x 5" 1D. �` NOZZLE MTG. RODS BY -ACCESS r0 CHECK OUT INSTRUCTIONS Q t t VENT. INSTALLERS FIRE DAMPER c \ QUICi( SEAL - _ E------� - r-- MTG. TABS BY 8 ACCESS PANEL — , 7 i1PT i GAYLORD MFR. `' 'cs e C� -� .. .. r`2re P. "eSj. 0 1P '.- tD�..'G._ ,c-el on t'? 1 _n.'ia:or. I PLENUM FUSE LINK BRACKET I ACCESS , NOZZLE PANEL - PANEL 26 MFP - FUSE LINK ,_ ` i _ --` DAMPER - •.er r�ar'�.? f.I.. ?t+ndic2:a_d on •�a c z • :s. 20 36 I HPF t�,ty a voyua^e c`y . e - : =fie �t j:stng as f GREASE f DRAWER 12.-4" �-,,f zs s F,. T P d:era;a MAINTENANCE INS-- Dc j S _;t+. ; Q R-102 -- TRUC[ION LABEL. ( - -. --e F,;.a.�'cn e�.Z e, -• N00.E 10 1 NOTE. HPF-U.L. LISTED HOOD - APPLIANCES PENA(RATION Fl(TING a ? _' = `' NOZZLES / ANSUL R-102 F , NOTE: FRONT OF BROILER PRE -PIPED BY 4, 75 FLUSHES WITHFRONT OF �-- 20.75 GAYLORD MFR. - I VENTILATOR AS SHOWN, BROILER 8'-6"(102") NIECO OUTLET 30 FIN CLC HT. INLET 960 -� M i G. I H T. i> A�SUL PIPING DETAIL _ BROILER + j i NIECO 960 ' ' f I ` 1 i ? 36 n o t:r. r'Lor l 1 FIGURE 1 C� � � Q-_ 1 . I -- 40" O.D. --� SECTIO�J VIEW ELEVATION i LISTING AND APPROVAL REFERENCES GASKETED COVER ACCESS PLATE ROOFING, 1N5ULATION be CANT ,------ 25.5 -- -, STRIP FIELD INSTALLED BY `.� ROOFING CONfRAC(OR. I Underwriters Laboratories, Inc. File Number MH13522 3/4 X 3 5/8 PRESSUER TREATED I - -- IC60 International Contzrence of yt FArr - WOOD NAILER ` Building Officials I I 28" PRINCIPLE OF OPERATION Ftse3r_ne_crr:o 2 �,1 1 14 1/8 X 4 1/4 X 2 — -- —' fF INDUCED DRAFT - ,i FLANGED OPENING —_ GREASE EXfFIACTIOrT BOCA - Building Officials & Code �J� t'rL FOR SUPPLY DUCI `-f The Gaylord 'CGX•BUl•h1A-ID(3K)' Ventilator extracts Adrrlinistrators International, Inc. E;Kri%,UST DUCT I 1 tt, 4 \ ' 90°b of the grease particles from the air s:rearn by ;zs ar:r Fa o^. No 57 3 { -- 1'4DUCED L I 25-5 centrifugal force_. This is accomplished by unique, f f oucf removable stainless steel 'extractor inserts' whtcn 1`13tional Fire Protection Association incorporate a series of horizontal bates. As the a:( maces through the extractors at high speed, f. is Well's 3:1 f-?�, re�ena cr Ni r ,-S5 � forced to maKe a series of turns around these baf!:es, .a.cr Fe -.:'.a; trcrn Coca:n, EG;.iiarr,r,;•- i forcing the heavier-than-air particles of grease to t? thro•hn out of :,he air s'rearn by cer:rifugat force. ine NS= - National Sanitation Foundation r I I s:,Cky'grease rerlalns in the extractor and the Iiqu, eC r.'ea:s a 1 raC e ;s cf N=5 StanCa , No. 2 �..� grease drains dov;n into the Grease cuaer and into , ? -__ Sr. _.- ,9f?as='.cup -,--- '— - -- --" Tnd ventita:Or also incor Orates an induced Ord self City Of Los Angeles r,lechanical / ROOF Le Aj§Y DUC T BY GAYLORD MFR. — - \ �\ / talancing sys ern (no r1ake-up air far• require) f�i r y -_� �. GAYLORD MFR. 9 / 'l dfa out toe m ,r r ,n Testing L.aborator ` 'f.3 3 l.nt? ?•'?d a d, ?Ct,j (O t^a lD'w?' % ,_. = .�.,-•'- ^..:.i+:_ v ,, i = - enGlatof c ia'n er Tn.s cooler air mixes wlrn t` a rvr ^ai23...`t P.a,... , h.,. 7:iG , .— - _ _ .-•�rr+�'� . grease laden air rerg d'a o_ an:; bf'er an ROOF CURES ISOMETRIC VIEW PLAN VIEW-he%i •`^' r -^Sc`- -� _w� reduces t^e :?rrP9'� -j'e of - ,e a r e':(? en:e•ng :"9 rlev: York City Board or Standards inse^s T'-.s is not a Cc'-"er.sd: g '(:? and Appeals • d (BY GAYLORD MFR) rna:ca•vo atr Ter,,._:Df as -e tnduc 2' niece cDr•?s in Cor:aC: '.v:n I`? 2 .^? ra •, a•?dT.^9- . D;J•'POS? of '-e Ind ed air t3 : reduce me a'c--�� ti :?r'lpefd:Cf? b?f7'? ,t ?r e(S I'. a °,!-a:: D( ir.S?r: :S hSF / V L r EiING I i BURIC - 25.50 i^e^ynacts n; ?a3? Et: a_, or a �i;/ ,i? _ GREASE EXTRACTION j: CLEANING 25 / • 1 8 3/8 - 8 7/8 - 8 3/8 A:,.-),- end of th kIn j j, t-? e a� irse:a ar• 1 (� I it e �D < dz- x; or 1 4 GRID CALL removed a-tc 'fresh2d or rak%d' a-ra men (.-:sed o.4 rt et'' BIRD SCREEN 1.25 _ ana re^!aced. To ease in a am.:a 1.25 r tn_ r_ Or t.`.9 extractor t I ,r.sers. an 'extra:'.or removal rcDt• is rrcvidaj wr ich 1 et:rnina:as tn? nee,', for kiLChan p3•sonnel t� roll t`)a 'r FIRE PROTECTION OD. 13 ^ - ` 1�jAy T-.e /° 3 ( is f3 : / rr°'y'�== `:r d^ A:-;: .= C< FACTOR T f1�7' -? + ill GA. F,fe Pr tz on j�s'?r Tr? _ z ? 25' ANGLE - r_ n 't _ -v F r-/,c 7�z GALL F z yr ..i1 t °e �x re�s.o ur :r , ,- T as r ` r. ' .si TOa -1 5a�,r� - - Aoff f/ 2 5 8 _ ���r, t,? �� �tf'•-- ?s, ?~ GENERAL SPECIFICATIONS too � l� zTs .s ,r• aid„ �_—,- ,• , ►.t s CLEANING ��� �• Z. 28 4 _ .4 1/4 C.,PTURc FFG TI /Err°SS - G-, y . _ _ _ , 1. 't, a vL .-_ C ra^ _,_ _ , f 'r, . :ram( Cr IarS. Y?'t'. 7'• , -- �. r- .:w ^'a3S2 ?t.. __. •ai _'1-1t -.vO (?t'C.dD'a ie.c:'a::pr ,�. T-5Gd'iO'-ftrC�; '.i',h.r.•�J�•}•t'•:a is 2., 2,, fa• is a r. � •-y' 4 f. `fl air f it C ritr�al v\I— •, `i NOTE: PROVIDE -' _ -e a •m / sz;ir_ vet:l. - - Las Les- .1 I _� \ r n: i� - - 2 Sd':S• ^a a C"dse et••i.`:iOn of cienrj of 9l�'.0 i, .t•r,' ._-_ DIiC( N07µ F 3 7/8" CASKETEU ACCESS 3s -?d s_e- aiy !:n'r9}: _ :'S ti.' d;--�vi` r±'^o.?'a:' c;:-e s^::a a r_re2sd ta'_':.^ �I - •�� COVER PLATE ( - � T``d ^:`e ,a.., E d .. 4S ^ UC:?d Of. �:d,r1ICSS�i: `at .. 4•' _ - _ 2-4 are �,-,:w:, a . 1 L t -� DRAWN BY: TEAIE: fj� 12 zna a: -? r� pr.�o;g g.n c !;!- t o art tr.0 r r r Ft N fd N 18 GA. S/S t2 2' C's.y .aC'� 1 -aS Tre Vo _r5 fir^.Bn C ?•'1. rCC '.�...^ 5 - i ,d ' 3._ O:C a:ei d = U t?Z�LE JD _? al -f7r r.?S ir,C c3:?d f_r, '? f,i3.:5. C' t od 'rr' ?.DrC.rd a�`: '-1 W �..t?rnperad outside a.r i` ALL WELDED t, b Cu° ^._ , e S•t'3~cr _. ar^oer reducing the [> O O� 0� Q�' s -- - SUPPLY DUCT BY GAYLORD a s - c _ -a . e� .a_s: a to ^ce a: e Tne induced air duci cola ' 1� �, f�•J.E / _, C.?' _ : -na,< r-t ,._, ;nclud?s a tuse Iu:, t.'tl Ca. -per to Comply with NFPA• EXNAUSi DUCT BY GAYLORD re r-1an:s Ire,en:ila:or is constructed of 19 gauge sm :a es:-? typd 04 number a finish and es t`; t — SGAI 1: t CHECKED BY: pre-p,ped for \n;:,I R-1C� Fire Prpt?ct.on System. All f ► � � p j 4 _ exposed piptr.t� r, chi^me sleeved and Gt ings chrome -- fi•tO1tf:R f10Z�LE \r la:ed. Tie verb:a or ;s U L. Classified, recognized b. ( �l i NUfE: DUCT IS APPROXIMATELY SUP. DUCT g � j�-^ 1 I �: J .S, rC60, BOCA & f15F .Ind rneet3 a!I requirements of ( _ BROILER I 1 4" LONGER THAN REQ'Q. CON IRAC TOR n I NFPA-,6 An tE� r�,1t.31e all welded stainless steel. --_•-- I f0 cut OFF TO SUIT JOB EXH. DUCT e.haust dent r; 1t,nrj and an 19 gauge all welded 1 1 13 7 /8' CONOI ICONS. supply duct 11 10fl 1 1,0 5 , ptit,ct FIRE PROTECTION t o D.' 23------__-__ d • r : � `llrAtiylNE� N0: t• {{ 8 •' 8• O.U/8" O.D, sEC rION A- A �c t D FILE NO: E`01AU`_i,r r91JC I PI'I-`( t1LIC. r - (BY 0A)iLORD MF P) (,Es'r C,l: rI C)fll> tAf F:1 ! • NA 0 D E L: C G X B D L- VIA- I D"- (R.K,)' , t , 5 n.. lily } r : { .- - . �,' .. '.. ...• _ .' -, try Y , t' - -sF uEr l'•"L •r�aa mom AIR VOLUME: LISTING AND APPROVAL REFERENCES , TOTAL EXHAUST. 1350 ACFM V -N L SP.: 1.25' ------ ACCESS HOLE FOR GAS LINE Underwriters Laboratories; Inc. ; I AND COMPUTER CABLE. rc� exrtAusr Far! ---- ( ! _ _ 1 ' EXH ,% r rile Number MH13522 _ \ 1 • �J�: J-BOXES FOR C)-- °-J ° ° • - B� ELECTRICAL ICBO - International Conference of (-- I CONNECTIONS •Building Officials r+LZriZSST` 1( I is l 24 I , Research Report No. 2':6' CHEMICAL INLET BOCA - Building Officials & Code ! ! I Administrators International, -Inc. L�'-I --13.5 F ----- J-BOX W/ BLANK COVER W / Research Fer�r, Plc. 07•;3 -- FUSE UNK ir 120 V. 20 AMP. CIRCUIT INLET WIRED TO J-BOX C EXHAUST DUCT BY —�, National Fire Protection Association rt_ n DUPLEX RECEPTACLE - C GA'rt ORD MFR. _ -- 120 V. 20 AMP, FOR Meets a!I requirefr ^;s o_! ki COMPUTERS.(NOT PRE-'MRED _ `-���`-�C"C�l i Vapor P.emova! from Cooking E �5 Gv prn?n;' f` N 24 j NSF - National Sanitation Foundation S/S DUCT ENCLOSURE Meets a re^, aof N :a -ard Nc 2✓ C \� 1 jn� N 1 >2h ✓r^e t; ti �--1 a �r 3'- 0' BY CAYLORD MFR, 'i ooC r/ H r 1 l ^ a FxTRAGrORIPlSERi-- J / % r! Z� h. PLAN VIEW i City of Los Angel..s Mechanical / If'j 16 - 16 -i- 4 Testing Laboratory I !! i t 3'- 0' ; ; ] a Lt. u: Resea•zn ne�ort ":c ,_ G EAS J r R `i �'' 00 m o o T''' 'N r f DUCT NOZZLE ----------- •---------- 4.5 9 ! r .. n E G� r E --- � t NOTE., r LE. SLO -''�'�, S S DUCT CiiASE 1 UV DUPLEX RECEPTACLE 3 t 2" FLANGE a °D / Z ECE GLE I / New York City Board of Standards =.RYER � to OPENING 97.75' LONG BY GAYLORD MFR. FOR FRYER COMPUTER• tD and Appeals GREASE EXTRACTION (5) GX-20 EXTRACTOR `��0 INSERTS REO'D. COMPUTER OPENING BS�� ^:c 53;-c- S v 0oo: I�i COVER FRYER COMPUTER-- r iz� v E- \ �! (IF USED) ' ACCESS PANEL 9 s : I ! o x O ° n I Pai 7'X 7'H. �i$6URGER ,----� 1 wv)Q u4.PLENUM t—KING x 0- NOZZLE t� '_ --- :� a: ( ----- _ _ ---- J in (2) ANSUL FUSE - J i �l LINK BRACKET PRINCIPLE OF OPERATION -J _ }d r r �j" COMPUTER a \• / I ( HPF ----"f I CABLE GREASE EXTRACTION 33 The Gaylord 'CGX-Ai3(BK)' Series Ventilator extracts EXTRACTOR INSERft T G x � i it 90% of the grease particles from the air stream by ANSUL I I i i• centrifugal force. This is accomplished by unique, 8'- 6" 24 NOZZLE I �, removable stainless steel 'extractor inserts' which ;' t-) CREASE 16 16 16 -16 16 14 -- FIN. CLG. H T. , 1 I INSULATION incorporate a series of horizontal barites. As the air CUP - 1 rtloves through the extractors at high speed, 4 is 16 j-�----27 18.50 25 - • 7 -+ `---- CENTER LINE LEFT r j I t t20 V DUPLEX forced to mace a series of turns around these baffles, =' -- --- 4t 4L it OF NOZZLES END t I 1 RECEPTACLE forcing the heavier-than•arr particles of grease to be , ` F f I thrown out of the air stream by centrifugal force. The FRYER J-BOX W/ BLANK COVER PLATE ___ _ _ _ _ _ _ _I-! `-r--r 5'- y" sticky r + + r _ --___� l / grease remains in the extra. or a, .d the liquified CLEANING } _ FOR FRY DUMP NEAT BLANKET 'N/ 1 , grease drains dorm into the grease guy: er and into the CC) 120 V. 20 AMP. CIRCUIT I ! ! grease cup. 4'x 3.5" HOLE IN -x RIGHT I I t SINGLE RECEPTACLE FOR WIRED TO J-BOX B THREE DUPLEX BOTTOM FOR GAS LINE END r FILTER MAGIC UNIT W ( I t 'r —DUCT NOZZLE RECEPTACLES AND COMPUTER CABLES. r / , CLEANING � � •?�-- 120 V. 20 AMP. CIRCUIT I W/ SEPARATE t At the end of the cooking day, the ex•ractor inserts are WIRED TO J-BOX B j REMOVABLE 28 k u-�-J 120 V. 20 AMP. FRYER - I removed and wished or soaked an^� men rinsed off -, _ - - �. CIRCUITS WIRED - 6 I j BACK PANEL and replaced. The grease cup is a;so ernNtled at this _ 1 ?; ji TO J-BOX A ( time. i + r PLENUM NOZZLE 1.5 --- ! f FIRE PROTECTION r �� C ff 11 j I The ventilator is factory pre piped for an Ansul R• 102 r `% '- .. +- Fire Protection System. There is one nozzle protecting FRYER NOZZLE a 9 + each fryer, one for the ventilator pl2n -n and one for IIr_11J Q .� ` REMOVABLE 8 the exhaust dut-t collar. The system meats all require- I � . ' O KICK PLATE ments of NFPA-96 and NFPA-17A• f I I j t i n C7 G p ---------W O CAPTURE EFFECTIVENESS - 1.50 8'-9" EXTRACTOR LENGTH 1.50 - r The Gaylord Model 'CGX•AB(BK)' is a low air volume t^ W � rn SECTION VIEW energy g FIRE PROTECTION .�1 9'-0' 108' "• - ener saving ventilator which has beer, designed � - � � t2: ( ) specifically for gas fryers and will effectrrely remove all of the smoke and grease laden air generated by the r, • Q O ELE VA TI ON cooking process when operated at designed volumes. r� -1- The N ventilators, when operated at the air volumes indicated on the plans, capture 1C0% of a c0 second smoke bomb with the fryer, opera:;•-� a: maximum output. r s GENERAL SPECIFICATIONS Gaylord Ventilator Model 'CGX-AB(BK)' is designed CHECK OUT INSTRUCTIONS specifically for gas fryers. The ventilate( is a high INSTALLATION INSTRUCTIONS velocity, low air volume, centrifugal grease extractor 1. Ensure that the ventilator is installed in the proper utilizing removable 'extractor inserts' having a grease relationship to the fryers as shown on the 1. Position ventilator in proper location_ Level the ventilator by 4. Install gas pipe down through opening behind exhaust duct.P extraction ef;icienc/ of S The extractor inserts are drawings. constructed of stainless steel and are easily removed 2. Check to make sure that the extractor inserts are turning the adjustable legs. for cleaning. The ventilator is free-standing and has a 5, Make electrical connections to J-Boxes A & B, located removable back kick in laceproperly. Rafe( to the maintenance CL panel and Fick plate for easy access P 2. Slide exhaust duct down through roof curb and Into the duct behind duct collar. to the rear of the fryers. A stainless steel duct instruction label on the ventilator). collar. NOTE: To accomodate various building confic ura- enclosure is provided which conceals the exhaust ` J 3. Ensure that the air volurne of the ventilator is no �°''`� tions, the duct is approx. 6' longer than normally required. 6. Make all Ansul connections. (Must be done by authorized dud, gas lines and conduit between the ventilator and 3/8° PIPE lower than the volume indicated on the drawings Cut if necessar/, fully weld exhaust duct to duct collar. Ansul Installer). finished ceiling. The ventilator includes duplex or the ventilator name pla:e, recepticals At bottom of unit for plugging in fryers and '" " �• a duplex receptical at one end for the heat lamp. It DUCT NOZZLE The exhaust volume can be checked by taking a 3. Mount exhaust fan. 7. Install stainless steel duct enclosure. a!so has a raceway built into the front of the unit for velocity reading across the inlet slot using an j mounting fr/er computers if desired. The raceway has anomometer as shown in Fig. 1. The average pre-cut holes for mounting the computers and a velocity should be no less than 350 FPlI �� duplex receptical for plugging them in. An opening is CHEMICAL SUPPLY ,�.•.y 24 24 J provided through the top of the ventilator far running INLET Smoke capture and grease extraction effir_iency i......J the gas line. The ventilator is constructed of 18 gauge are dependent upon the proper air velocity at the ........ \_ stainless sleet �''°� type 304 number 4 finish, and is pre PLENUM N01ZLE inlet slot of the ventilator. piped for Ansul R-102 Fite Protection System. All l� exposed piping is chrome sleeved and fittings chrome HPF i plated. The ventilator Is U.L Classified, recognized by ICBO, BOCA & NSF and meets all requirements of „�, <-oT ter_ �� �,..�,,� NFPA-96. An 18 gauge all welded stainless steel s"s''''� ""� 18 CA S/S DUCT exhaust dud 8'-6' long is supplied. ENCLOSURE BY CHEMICAL 1 4. CAYLORD MFR, . ch, a - INLET MAINTENANCE INSTRUCTION oe LABEL. • ACCESS PANEL t r+ SLOT p�+� ?CSTCN :;cN$iN; NFD ON 10' HIGH APPLIANCE NOZZLE o (TYP. OF 6 I COMPU TER ) OPENING COVER ® OPENING FOR GAS LJ�t.Ga LiD Cf LINE & COMPUTER wLET SAC r REMOVABLE CABLES. BACK PANEL FIGURE 1 8'-6. RECESSED f HANDLE HPF _ r (NP. OF o� 18 GA S/S ALL WELDED KICK PANE NOTE: HPF-PEN TRAnON FIL LISTED � NG a ;. FURNISHED BY CAYLURD KICK PANEL � MFR. PLENUM NOZZLE - NOTE: - Npc-----�_ DRAWN BY: DUCT IS APPROXIMATELY 6' LONGER T}LAN RE 08 COPIT'R TO CUT OFF TO JOB R.IP. { ;/ / CONDI TIONS, 1 k jt - . SCALE: -.-_ 'CHECKED BY ��- AI\jSUL PIPINC DETAIL N. S'. (t 13 3/8 8 7/8 O.D. -- ! O.D. DRAWING NO: FROM -I 1`-10METRIC VIEW BACK ISOMETRIC VIEW EXHAUST DUCT C_ J 11. FILE NO MODEL. C GX AB-6 BK i 4 E 3 - - �► 8 0 1775 -- NOTE : t 0 " �q 8 _ INSTALL FIRESTAT IN RETURN �� 500 UNITS AIR PLENUM OF A/C UNITS 1 & 2. 184r� TO 20x-131 r _ , RETURN RISER 525 (A:1 C-3 ��. y �---� I I I I 7 #0 EF- i 450 � " 1. 32x14 TO 19x14 II 12 SUPPL ( RISER • 1 1 I ( - --- -- 1 500 12"(0 12"� 10 "0 %1375 0 `r° 60,I- - - - NOTE32x14 II I l 18 GAUGE CONTINOUS WELD EXHAUST d I r 18 � TO 18 14 �' I I DUCT UP TO EF 1 AND EF-2 REFER TO FAN SCHEDULE UNIT NUM'19ER EF-1 EF-2 EF-3 AREA SERVED BROILER FRYER R/R MANUFACTURER . GREDKCK GREENHEC< GREDI-ECK ALT. FAN ?&M ACME ENGINEERINNG & MFG. COFP., PENN VENTILATOR CO., INC. (SEE SUPPLIERS LIST MODEL NNUTAREFI fxA3E-140HP 14-7G (BK) a-BE-140FP 14-70 (BK) ;G-80-D CFM 1000 1350 b O Q •' STATIC PRESSURE 1.25' 1.25' 25' FAN H.P. 3/4 3/4 1/20 DRIVE BELT BELT DIRECT RPM 1811 2050 15W ELECTRICAL SERVICE 206/1/60 208/l/60 116/1/60 ROOF OPENING REQUIRED 23X23 22X22 17'X17', ROOF CURB' YES YES YES BACKDRAFT DAMPER No - No YES BIRDSCREEN NO No YES GREASE TROUGH YES YES NO INTERLOCK YES YES YES r �s Al Y �� / i-•# (L ` n x � U E vz; j 00 �- S r g�oyy.() cc: z CU t►J w r. z�1 � Z ryc Z . ; # w : 3 , �1� � to � ✓b�' fd�f,d�j � X `- SUPPLY RISER EF-2 I I ! ►I ( SHEET EQ-2`FOR ADDITIONAL DETAILS. ! i I # ell ;c� U 12"� -� u - Zotk :i A THRU D A TRlRU D E E z r AC-1 I I fil - _I-Eling _^ TYPE OF HEAT S HEAT GAS FEAT ELECTRIC ELECTRIC n r 18 "� TO 20X13Y I I I # y_-h, 8 UNI f N C 1& 2 A/C 3& 4 A/C 1& 2 A/C 3& 4 RETURN RISER 18"lA TO 2Ox13Y 8 �P AC� I I ! I R RETURN RISER 1 " - 9 550 MODEL NTUMBER JE008 48DJEo07 SODJoo6 60DJ007 A/C-2 I III I 12 COCi INNG CAPACITY BTU/Ffi (ARI) ,500 71,000 59,500 71.000ij fi 7 r. L - - 18"� 400 LIJ CFM s�L Y AIR o 400 2000 2400,. J 12"�' 12"gyp ) 9 I I O I I CC CE E.E.R. 9. ' .4 9.3' 8.7 ' HEAT INPUT (BTU/HR. R. OR KW,) 11 ,000 11 ,000 -75 12.0 KY! 12.0 KW t{ A/C- 4 �--- r' OPTIONAL _ I I OPTIONAL � : MINI" CIRCUIT AMPs 30. 3 .2 47.5 47.0 �r DUCT I I DUCT `b B�c6 ° 10 °�D MODEL NUid3ER YCO 60A FiOA YCD 76A A TCD080A300A TCD075A300A HEATER - HEATER �r � �t-' � COOLING CAPACITY BTU/FFN (ARI) ttfi E-- F - II 1 6 -; 6 so , oo 7z o0 60 ,000 72.000 k ?� j Z CFM SUPPLY AIR 2000 2 2000 2500 �{ 650 650 500 T 125 E.E.R. 9.0' 8.8 9.5' 8.55 f� �---J SD HEAT INPUT (BTU/FV. OR KW.) 135,0 tzo, 00 7:45 KW 6.75 KW , 4 -T AC-4 ������ �- 6 " 5 125 I `/� MINIMUM CIRCUIT AMPS 32 38 36 37.3 ' ` " Q < A$ 75 l 18"� TO 20X13Y MODEL NUMBER ZCtX1 10325 D2CG0 10325 D2CEO60A25 D2CE076A25 A� 2 10 - -, RETURN! R I SER T A/C-1 200 T - ^� COOLING CAPACITY BTU/HR (ARI) 58,0 0 75 00 59,000 75,000 - 20o z o 2000 2400 „ " 6 " 10 ' LL EUIT �- CFM SUPPLY AIR `� 12 X12 I 7 E.E.R. 9.0 8 4 9.15' 8.4 EF-3 EXHAUST 5 j �2X14 7 9X14 450 >_ i DUCT UP 100 5 ! UPPLY I�ER HEAT INPUT (BTU/HR. OR Kw.) 12 ,000 F5.000 8.0 KW 8.0 KW i 6'� TO EF-3 ; � . 175 I - 30 5 �- MINIMUM CIRCUIT AMPS �37.9 35,9 37.9 I MODEL HIABER 16-653 NGC516-8 CHA10-663 CHA16-823% (� r` 7� TEMPERATURE SENSOR COOLING CAPACITY BTU/FEN (BTLH) 8 ,zoo 76,400 60,100' 76,400 LOCATION FOR OPTIONAL z CFM SUPPLY aIR Too,2600 2000 2600 R/R MID VESTIBULE DUCT HEATER. z ' 9 9.0 8 4 r, - NOTE: MAXIMUM 12 -0 FLEX � E.E.R. • 9.0 • r„ DUCT TO EACH DIFFUSER HEAT INPUT (BTU/HR. OR KW.) 25,000 135,000 /.5 KW 7.5 KY Lu y f MINI" CIRCUIT AMPS 36.0 29,0 31.0 39.0 ELECTRICAL SERVICE - 208III IPA • SEER STANDARDH VA.C, PLANACCESSORIES - SUPPLY ALL UNITS WITH DISPOSABLE FILTERS, OA.H000 DAMPER$ THET'JAOSTATS. CONTRACTORS NOTES SCALE: 1/4"=1, _0" LEGEND �-tC f C5 ; A I u I li' . ARe, _ C,t,C-7Pi( c AIR CONDITIONING CONTRACTOR LEGEND MAY CONTAIN ITEMS NOT USED IN THIS BUILDING. 1 THE AIR CONDITIONING CONTRACTOR SHALL FURNISH AND INSTALL Al AIR CODITIONIN G 4 EXHAUST FAN OPENINGS ARE BASED ON GREENHECK EQUIPMENT IF OTHER UNITS, EXHAUST FANS, DUCTWORK, INSULATION, DIFFUSERS, THERMOSTATS, SMOKE DETECTORS, FANS ARE USED VERIFY ROOF OPENING REQUIREMENTS. FIRE DAMPERS (IF REQUIRED BY LOCAL CODES), AND ELECTRIC HEATERS. (THERMOSTATS 5. ANY FRAMING REQUIRED FOR DIFFUSER INSTALLATION IN CEILING SHALL BE BY SHALL BE PROVIDED UNDER MASTER CONTROL SYSTEM BASE BID CN_Y) . CONTRACTOR TO VERIFY. FIRE DAMPER (FD ) THE GENERAL CONTRACTOR. 2. THE AIR CONDITIONING CO TTRACTOR SWILL INSTALL ALL HOODS AND WELDED 6GENERAL CONTRACTOR SHALL SUPPLY AND INSTALL COMBUSTION AIR LOUVERS FOR GAS EXHAUST DUCTWORK PER LOCAL CODES. ALL HOOD EXHAUST DUCTWORK SHALL . ( VOLUME DAMPER (VD) 'HAVE CONTINUOUS WELDED SEAMS AND CONNECTIONS. (HOOD SUPPLIED BY OTHERS) WATER HEATER. (D TEMPERATURE SENSOR 3, ALL AIR CONDITIONING UNIT CURBS SHALL'BE SUPPLIED BY THE AIR CONDITIONING 7. IT IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR TO TEMPORARILY STORE ALL AIR CONTRACTOR. CONDITIOYNING CONTROLS 'WHICH ARRIVE AT THE "SITE PRIOR TO INSTALLATION! DATE. r SUPPLY DIFFUSER - 4. ALL AIR CONDITIONING UNNIT CAM DESIGN SHALL COMPLY 'WITH NATIONAL ROOFING FI FFC,T_RI ,CAL CONTRACTOR ONE WAY BLOW CONTRACTORS ASSOCIATION REQUIREMENTS. CURBS SHALL BE A MIN. OF 14' HIGH. 5. LEVEL FRAMES SHALL BE PROVIDED WITH A/C UNIT CUBS TO CGMPENSATE FOR 1. THE ELECTRICAL CONTRACTOR SWILL FLRNISH AND INSTALL PITCH PANS FOR POWER AND CONTROL HIRING AND MAINTAIN 12' MINIMUM CLEARANCE FROM BACK PANEL OF RE -TURN AIR DIFFUSER - J TS RCAF PITCH (BY TFE AIR CONDITIONING CONTTRACTOR). AIR CONDITIONING UNITS. 6. AIR CONDITIONING CONTRACTOR SHALL SUPPLY FULL SIZE 'P' TRAPS (USING PLUGGED TEES FOR CLEANING) FOR ALL CONDENSATE PAN CONECTIONS. 2. THE ELECTRICAL CONTRACTOR SHALL INSTALL ALL LOW VOLTAGE CONTROL 'HIRING (UNLESS A/C UNIT CONTAINS INTERNAL TRAP.) FOR AIR CONDITIONING UNITS AND ALL FANS. COORDINATE 'WITH AIR CONDITIONING AND ELECTRICAL PLANS. (LOW VOLTAGE WIRE SUPPLIED BY ELECTRICAL CONTRACTOR). 7. ALL FLEX DUCT SHALL BE U.L. LISTED, CLASSIFIED AS A CLASS 1 AIR DUCT. AND MEET LOCAL CODE REQUIREMENTS. 3. THE ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL DISCONNECTS FOR AIR CONDITIONING UNITS. 8. ALL SUPPLY AIR DUCTWORK SHALL BE INSULATED WITH 2' X 1 1/2 LB. (OR EQUAL) DENSITY DUCT INSIA_ATION WITH FIRE RATED VAPOR BARRIER (R-6). 4. THE ELECTRICAL CONTRACTOR SHALL USE A MINIMUM OF 4'-6' SEALTITE FLEXIBLE FLAW AND SMOKE RATING - 25 AND 60 RESPECTIVELY. CONDUIT *-&I WIRING, KITCHEN HOOD EXHAUST FANS ON ROOF SO THAT FANS MAY BE 9. ALL DUCTWORK TO BE INDEPENDENTLY HUNG FROMSTRUCTURALMEMBERS. REMOVED FROM CUfM AND PLACED ON ROOF FOR CLEANING EXHAUST DUCTWORK. 10.ALL DUCTWORK SHALL BE FABRICATED AND INSTALLED PER SMACNA LOW VELOCITY 5. NFPA (NATIONAL. FIRE.CODE) REQUIRES A FIRE INTERLOCK SYSTEM BE INSTALLED DUCT MANUAL.(LATEST ISSUE) ON HOOD EXHAUST FANS AND GAS FIRED APPLIANCES. tHEREFORE, THE ON/OFF PANEL AND MASTER RELAY PANEL ARE THE MINI" REQUIRED EQUIPMENT NECESSARY 11.ALL DOVETAILS INSTALLED IN A/C DUCTS/PLENUMS SHALL HAVE A VOLUME COtffRCL TO MEET CODE, DAMPER. 12.AIR CODITIONING CONTRACTOR SHALL COORDINATE DIFFUSER LOCATIONS WITH THE PLUMBING CONTRACTOR REFLECTED CEILING PLAN. 1. THE PLUMBING CONTRACTOR SHALL PROVIDE & INSTALL FLUE GAS EXHAUST VENT FOR HOT 13. THE AIR CONDITIONING CONTRACTOR SWILL FURNISH A WRITTEN GUARANTEE COVERING WATER HEATER. A ONE YEAR PERIOD FOR ALL PARTS, LABOR AND SHIPPING COSTS, AND AN ADDITIONAL 2. PLUM•lBING CONTRACTOR TO PROVIDE & INNSTALL CONDENSATE DRAINS FOR ALL A/C UNITS FOUR YEAR PERIOD FOR THE A/C COMPRESSOR AND HEAT EXCHANGER PARTS. ACCORDING TO LOCAL CODE REQUIREMENTS. ' 14.THE AIR CONDITIONING COTTRACTOR.SHALL, UPON COMPLETION OF PROJECT, PERFORM 3. PLUMBING CONTRACTOR TO COORDINATE PLU9BING VENT STACKS 'WITH OUTSIDE AIR INTAKES A COMPLETE TEST AND BALANCE OF ALL EQUIPMENT. REFER TO SECTION 1691.00 OF OF A/C UNITS & SUPPLY FANS. MAINTAIN AT LEAST 10'-0' MIN. CLEARANCE OR PER BURGER KING SPECS. BOOK FOR TESTING FORMS AND PROCEDURES. LOCAL CODE REQUIREMENTS. 15.WHEN 'WELDING STAINLESS STEEL(OR GALVANIZED) EXHAUST DUCTWORK, USE EVERDOR 4. PLUMBING CONrR. SWILL PROVIDE & INSTALL GAS SHUT-OFF VALVES FOR BROILER, FRYERS, RODS o 3/32 AND CARBON ROD A.C. HOLLOW CENTERS o 3/16'. AND BREAKFAST Hi000 (WHERE BREAKFAST HOOD IS USED.) 16.PROVIDE DUCT MOLNfTED SMOKE DETECTOR FOR IN SUPPLY PLENUM FOR A/C UNITS WITH OVER.2000 CFM Cr SUPPLY AIR. FIRESTAT SHALL BE PROVIDED FOR ALL OTHER UNI SEE BURGER KING SPECS BOOK FOR MANUFACTUPERS' MODEL MASERS. 17. AIR CODITIONING CONTRACTOR SHALL FURNISH MASTER RELAY PANEL. AND .CONTROL PANEL. REFER TO MASTER CONTROL SYSTEM SHEET. QENFERAI- CONTRACTOR 1. rtr- GENERAL CONTRACTOR SHALL LOCATE, CUT, AND FRAME ROOF CPENINGS AS'SHOWN FOR ALL AIR CODITIONING EQUIPMENT AND EXHAUST FANS. SEE ROOF FRAMING PLAN. 2. IT IS VERY IMPORTANT THAT ACCURATE MEASUREMENTS ARE USED WHEN LOCATING EXHAUST FAN ROOF OPENINGS TO INNSURE THAT NO OFF -SETS ARE REQUIRED IN THE EXHAUST DUCTWORK FROM THE KITCHEN HOODS. COORDINATE ROOF OPENINGS WITH -THE KITCHEN EQUIPMENT PLAN AND EXHAUST HOOD PLANS. OBTAIN THE CORRECT PLANS FROM THE KITCHEN EQUIPMENT SUPPLIER. 3. AIR CODITIONING ROOF OPENING SIZES AND ROOF CURBS ARE, BASED ON CARRIER 'GAS HEAT' EQUIPMENIT. IF ELECTRIC HEAT IS REQUIRED OR OTHER EQUIPMENNT IS USED, VERIFY ROOF OPENING REQUIREMENTS. NOTE: .FOR ICEMOTE MACHIONDENSER o r -�- -1 e EXHAUSTFANS1 & 2 SHALL DISCHARGE F 40" ABO/E FINISHED ROOF OR AS PER L - J LOCAL. CODE REQUIREMENTS. FIELD VERIFY EXACT LOCATIONS OF EF-1 & EF-2 W/ KITCHEN EQUIPMENT SUPPLIER. EF-1 GAS CONNECTION CTYP. EACH A/C UNIT) -y REMOTE CONDENSING A/C-1 A/C-2 UNIT FOR COOLER & r - FREEZER BY OTHERS aL - - J PITCH FOR FIELD POWER SUPPLY CONNECTION FUTURE - ANTENNA (TYP. EACH A/C UNIT) O FIELD -CO NTROL WIRING CONNECTION NOTE (•TYP. EACH A/C UNIT) MAINTAIN A MIN, OF 10 ' -0 " CLEARANCE FROM ROOF SCUTTLE - ANY EXHAUST FAN TO ANY FRESH AIR INTAKE. - - ° %EFA/C-4 ALT.' REMOTE - 3 corDENISER ZI FOR "SOD A ME FACTORY r MASTER RE►_AY }PANEL/ CONTROL PANEL (44" A.F.F, MIN,) DIFFUSER OR GRILL NUMBER I CFM Q A/C UNIT OR FAN NUMBER ROUND FLEX DUCT ROUND METAL DUCT AIR BALANCE SCHEDULE - UNIT NUMBER RFILRN AIR OUTSIDE AIR EXHAUST AIR MAKE-UP AIR A/C-1 1375 626 A/C-2 1375 625 A/C-3 1775 625 A/C-4 1775 825 EF-1 1000 300 EF-2 1350 EF-3 350 TOTALS 630o CFM -2600 CFM -2700 CFM 6300 CFM BUILDING POSITIVE PRESSURE - -100 CFM I �xf � SD DUCT SMOKE DETECTOR ' ( SEE NOTE 16) 3 KW OPTIONAL DUCT HEATER (ZONES A & B ONLY) OUTDOOR WALLMOUNT GRILLE DIFFUSER SCHEDULE g �L SYMBOL NECK TYPE SIZE DUCT CONNECTION SIZE MODEL NUMBER FINISH GRILLE BOOT SIZE OPENING FRAME TYPEcl REMARKS QTY { 1 15x15 SUPPLY 4 WAY 12'm 5000-MI6-54 ALUTAINAAA , 15X15 T-BAR ti 3A. r 2 12X12 SUPPLY CORNER 8'm 6000-MO-SC ALUMIt&M 12X12 T-BAR_ 1 Cr 3 12X12 SUPPLY 3 WAY 101m 5000-M48-S3 ALUMINUM ., 12X12 T-BAR 4 6X6 SUPPLY 1 WAY 8'0 5000-Mt-S1," ALUMINUM 6X6 9 3/4' SQ. 2 -_ 5 10X10 EXHAUST 610 F4i ALUMINUM 10X10 10 1/4, SQ. 4 6 6,(6 SUPPLY 1 WAY 6 5000-M1-S1 ALUM1INdid 6X6 9 3/4' $Q. 2 � , ;,.•.. 7 24X24 SU1 R Y PERFORATED loll 7500-6 At IJUTN M INCLUDED T-RAP 4 8 12X12 SUPPLY PERFORATED 7500-6 ALUMINUM INCLUDED. T-BAR ,4 9 24X24 RETURN 18'� CC Gf1-ff1 ALUMINUM 22(22 T-BAR 4 f ' HVAC ROOF PLAN - - - ._ �Cn AI r. .1 it)A .1 4 AY r.1 _ f. • .. 1. ',: , r . .: ,.- • 9•'sr s. a .. .. .. .. • ,.d`e r.. a.., _ _ .- [ , 7. a . . C P i '�iw• va. , 1. i ... .. 176,111, ' E. .-.. . .. ti .. ... ... ..i. Jr'• -:Y. '.9'. _ J L _ x ll...a _Y-. , .� F r '�" K. t - .. • � t/ a. !' - . rx•' . .�§` .. y,-, .. .'r» 'Fi , , < _ .' *, r ... . t .. .y .3 • tr . .r t . z - r yj i K .' .. . ,:. : ... .. 1 -.•r^, '•. ..y. _.., .. _ t�..i' n .> .. . � . a. .,- - t. ,. .D. • .a t S" a j,� �ad,' „r r �.• s r ,. 3 , � -C .Y . f 6. +, ,. .. x r i< .. .. . J. -.c! •�. ., ,. }. _ t� to �t' � .ram ... �su- -.. G a• .. ..'.. D- a -a �""_ e. ,- .... a E .. _. ._ tt .X ..a : )�, .F ��y} r s ,.v i v� . 'Sfi . .ri F + }} .4 r:. A v5• '". r.c �( ^:�... 3" , _.R"t i � f. u s ✓ _ , t. .J' {# i .- r , P ,=G i- l� ! .e Si s, . • L :C. ..` _ i _ ,. , _ , .. i. .,.�.-.• - -'J ti •^l•%••' <-, J s 3 a l< o ., „f , ar _ .• _ r F .. .> � . ,., . .. ': >+ +.. .... :.. .J„ r r, ,. _ . -.. ,. .._,a.' ..., .. , .• y � r .- .. .•.> H .. .: 3 t .. .. L - t7• ,.<�.. . � ..� d*". #i" ..'# rs .+1w, ,... < & .aY _ _.. .... c .,, ... _. �F, _s .<.. -... r.,-,.,. .,.,•_ ., ..a ..... . _ ,>.. ,.r .. ,. ,,u t J >T.. ... , r J t. 1:.. .t ._ < s. SS . > �' -,.• .-, . .. f r , _ , .,z,.. . > . �..ge. a• �`-e« ,.,. -., _. :, � a ' ' • -� -�� //''-=< .. . �: -^*'Y` t ((�f ) s, •=3�?.. .� Y .. � .. 3'3 ?" .-.: t' .�, . ..:. Y .. �}''.., 'x .L• �„i'. hf i' �. ,. d - • k .t ,.G i de «'� /'..,r� 5,..... T .y •-..< ° ,. .. _ 'l1 .,,..�' Y .• i. .. � 1. < .. M` }. ,..�+. '.. '8 •r ' �"'';,. <. .. .. #' i' ° � . � . •:.�.. .„. •F: !r4. ✓. .... � .. e h� . d ,c. 6. ,. t�, F f ,. '� .<-. , , .., l r z•`' , ..f,• y ,,.xP. ... _.._ -. .. +f°Fx .,, , _ .. � _.c �."� dt6 t.. ... rM�t.. _. ,. .. ^`i -. ,r. ., ,.s _�F.. 3 � .., .. .r.. �`, _. ..,. „a .s ,. ,a..S• ,� � .., ..a _..., t.. ., .,.<. .�•.a._r...: a_..a .....•.�. ..,. c... ._ _.i'`t".., ,. ,dr.n}. �: .<•,... ,.., t�. .., ,., ta. d' .* .d .? ,-% e`:,. Tt..r,. -z.G' .:�c r...r,. k-`'.. i., : 'e a.�x... .i,.Y.t�k�<� fu.,,V,f n�j-rt;fi-� �•'i���- a "% ib v Y.�",:d �` ,rs%? 12"� 525 r 1775 T TE NOTE: 5�*ED �0 -- - INSTALL FIRESTAT I'N) RETURN 7 10"(P - - AIR PLENUM OF A/C UNITS 1 & 2. /C-3 400 18"(P CT) FsD - - -� -� 12"� 1 1 - 700 500 II I ---� E - -� 50o I I i I I 7 EF-1 � 12 " (C -. _ --12 " �b 1375 II Ii 1 3 NOTE: II II 18 GAUGE CONTINOUS WELD EXHAUST DUCT UP TO EF-1 AND EF-2. REFER TO 18"� - AC-1 AC-2 II I 1 I SHT EO-2 FOR ADDITIONAL DETA S IV Y 24X18X22 PLENUM -�-�- EF-2 I �I W/ END CAP . -� -�- I i > 2 " SEE TYP. DETAIL fil ' - � SHEET AC-2, -► 18"� OPT. HEATER { I { it i 8 9 8 SEE LEGEND. I I 550 1775 -12',V 550 12'o-- 12"(�-- 9 T 400 1375 8"0 A/C-4 �- -- - �- 1 II 6 6 • `� � 100 t 6 r W -I �- II OPT. HEATER SEE LEGEND . 100 6 " t 650 650 r 6"0 4 SO • .� 5 125 4 EF-3 75 D-4 10 "IT - 2 125 , ,10" A/C 1 200 T � y .. •�- OIT 12 X 12° 7 6"(p E10"� XHAUST 5 �'"� DUCT UP 450 TO EF-3 100 175 TEMPERATURE SENSOR _ LOCATION FOR OPTIONAL - R/R AND VESTIBULE DUCT HEATER. J) NOTE : MAXIMUM 12' -0' FLEX DUCT (0 EACH DIFFUSER.ALr. H.V.A.C. PLAN (PLENUM CURB SCALE 114'-1 ' -0'" FAN SCHEDULE UNIT N A43ER EF-1 EF-2 EF-3 AREA SERVED BROILER FRYER R/R M1AN(FACTLffR GREENHECK _ YCU3E-14OW GREFNdECK GREENFECK &T FAN MFRS= ACME ENGINEERING & MFG..Cff., PENN VENTILATOR CO., INC. (SEE SUPPLIERS LIST MODEL NUMBER 14-70 BK CU-E-140Ff CLAN (BK G-80-D CFM 1000 1350 350 STATIC PRESSURE 1.25' 1,25' .25' FAN H.P. 3/4 3/4 1/20 DRIVE BELT BELT DIRECT RPM 1811 2050 15W ELECTRICAL SERVICE 208/1/60 208/l/60 115/1/60 ROOF OPENING REQUIRED 23X23 22X22 17'X17' ROOF CURB YES YES YES BAWRAFT DAMPER NO NO YES BIRDSCREEN NO NG YES CREASE TROUGHI YES YES NO INTERLOCK YES YES YES CONTRACTORS NOTES LEGEND AIR CONDITIONING CONTRACTOR LEGEND MAY CONTAIN ITEMS NOT I. THE AIR CONDITIONRING CONTRACTOR SHALL FURNISH AND INSTALL ALL AIR CONDITIONING 4. EXHAUST FAN OPENINGS ARE BASED ON GREEttECK EQUIPMENT. IF OTF£R USED IN THIS BUILDING, PACKAGE A / C UNIT SCHEDULE ZONE A TFffl D A TFW D E E' _TYPE OF HEAT GAS HEAT GAS HEAT ELECTRIC ELECTRIC UNIT NUMBER A/C1 &2 A/C 3&4 A/C1 &2 A/C 3&4 MODEL NAff-R 480JE000 48DJE007 600J006 50DJO07 COOLING CAPACITY BTU/HR (ARI) 59,500 71.000 59,500 71.000 H CFM SUPPLY AIR 2000 2400 2000 2400 CIE E.E.R. 9,3° 8.4 9.3' 8.7 U FEAT INPUT (BTU/FR. OR KY.) 115,000 115,000 12.0 KW 12.0 KW MINIMUM CIRCUIT AMPS 30.3 .34.2 - 47.6 47.0 MODEL NUMBER YCDO60A3HOA YCDO75A3HOA TCD06OA300A TC007WOOA COOLING CAPACITY BTU/FR (ARI) 60.000 72.000 60,000 72,000 Z CFM SUPPLY AIR 2000 2500 2000 2500 E.E.R. 9.0' 8.6 9.51, 8.65 FEAT IN'F'IUT (BTU/FR. OR KW.) 135,000 120,000 7.45 KW 6.76 KW MINI" CIRCUIT AMPS 32 38 36 37.3 MODEL NUMBER D2CGOOON10326 D2CGO76N10325 D2CE06OA25 D2CE076A25 COOLING CAPACITY BTU/HR (ARI) 58,000 75.000 59.000 75,000 .! CFM SUPPLY AIR 2000 2400 2000 2400 0 r E.E.R. 9.0' 8.4 _ 9.15' 8.4 FEAT INPUT (BTU/FR. OR Kilt) 125,000 125,000 8.0 KW 8.0 KW MINIMUM CIRCUIT AMPS 30•5 37.9 36.9 37.9 MODEL N)MBER GCS1B-653 GC516-823 CHAIB-663 CHA16-823 COOLING CAPACITY BTU/FR (BTUR) 61,200 76,400 60.100 76,400 0 CFM SUPPLY AIR 2000 2600 2000 2600 J E.E.R. 8.9 9.0 8.4 9,0 HEAT INPUT (BTU/Fit, OR KW.) 126.000 135.000 7.5 KW 7.6 KY MINIMUM CIRCUIT AMPS 29.0 36.0 31.9 39.0 SERVICE -208/3/60 EACCES - SUPPLY ALL UNITS WITH DISPOSABLE FILTERS, CA HOOD DAMPER & THERMOSTATS. UNITS, EXHAUST FANS, DUCTWORK. imu- TICN, DIFFUSERS, THERMOSTATS, SMOKE DETECTORS, FMS ARE USED VERIFY ROOF OPENING REQUIREMENTS. CONTRACTOR TO VERIFY. FIRE DAMPERS (IF REQUIRED BY LOCAL CODES). AND ELECTRIC (EATERS. (THERMOSTATS SHALL 8E PROVIDED UNDER MASTER CONTROL SYSTEM BASE BID ONLY). 5 ANY FRAMING REQUIRED FOR DIFFUSER INSTALLATION IN CEILING SHALL BE BY THE GENERAL. CONTRACTOR. EEE] FIRE DAMPER (FD ) 2. THE AIR CONDITIONING CONTRACTOR SHALL INSTALL HA HOODS AND 'WELDED "PER LOCAL CODES. ALL Hi00D EXHAUST DUCTWORK SHALL 6. GENERAL CONTRACTOR SHALL SUPPLY AND INSTALL COMBUSTION AIR LOUVERS FOR GAS F-- VOLUME DAMPER (VD) HAVE CO TINUOUSDUCTWOR -HAVE CONTINUOUS WELDED SEAL AND CCNvECTICNS.(FROOO SUPPLIED BY OTHERS) WATER HEATER. 3. ALL AIR CONDITIONING UNIT CURBS SHALL. BE•SUPPLIED BY THE AIR CONDITIONING 7. IT IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR TO TEMPORARILY STORE ALL AIR T TEMPERATURE SENSOR O CONTRACTOR. CONDITIONING CONTROLS WHICH ARRIVE AT THE JOBSITE PRIOR TO INSTALLATION DATE. SUPPLY DIFFUSER 4. ALL AIR CONDITIONING UNIT CURB DESIGN SHALL COWLY WITH NATIONAL ROOFING FI F•.CTRICA1_ CONTRACTOR , ONE WAY BLOW CONTRACTORS ASSOCIATION! REQUIREMENTS. CU48S SHALL BE A MIN. OF 14' HIGH. 5. LEVEL FRAMES SHALL BE PROVIDED WITH A/C UNIT CUFRBS TO GATE FOR 1. THE ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL PITON PANS FOR POWER •WIRING HOOF PITrI.i (BY TFE AIR CONDITIONING CONTRACTOR) AND CONTROL AND MAINTAIN 12' MINIMUM CLEARANCE FROM BACK PANEL OF _ AIR CONDITIONING UNITS. 6. AIR CONDITIONING CONTRACTOR SHALL SUPPLY FULL SIZE 'P' TRAPS (USING PLUGGED TEES FOR CLEANING) FOR ALL CONDENSATE PAN CONNECTIONS. 2. THE ELECTRICAL CONTRACTOR SHALL INSTALL ALL LOW VOLTAGE CONTROL WIRING (UNLESS A/C UNIT CONTAINS INTERNAL TRAP.) FOR AIR CONDITIONIING UNITS AND ALL FANS• COORDINATE WITH AIR CONDITIONING AND. ELECTRICAL PLANS. (LOW VOLTAGE WIRE SUPPLIED BY ELECTRICAL CONTRACTOR). 7. ALL FLEX DUCT SHALL BE U.L. LISTED. CLASSIFIED AS A CLASS 1 AIR DUCT, AND _ MEET LOCAL CODE REQUIREMENTS, 3. THE ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL DISCONNECTS FOR AIR CONDITIONING UNITS. 8. ALL SUPPLY AIR DUCTWORK SHALL BE INSULATED WITH 2''X 1 112 LB. (OR EQUAL) DENSITY DUCT INSULATION WITH FIRE RATED VAPOR BARRIER (R-8). 4. THE ELECTRICAL CONTRACTOR SHALL USE A MINIMUM OF 4'-6' SEALTITE FLEXIBLE FLAME AND SMOKE RATING - 25 AND 50 RESPECTIVELY. CONDUIT WHEN 'MIRING KITCHEN HOOD EXHAUST FANS ON ROOF SO THAT FANS MAY BE `s 9. ALL DUCTWORK TO BE INDEPENDENTLY FUNG FROM STRUCTURAL MEMBERS. REMOVED FROM CURBS AND PLACED ON ROOF FOR CLEANING EXHAUST DUCTWWA . 10.ALL DUCTWORK SHALL BE FABRICATED AND INSTALLED PER SMACNA LOW VELOCITY 5. NFPA (NATIONAL. FIRE CODE) REQUIRES A FIRE INTERLocK SYSTEM BE INSTALLED DUCT WANUAL.(L.ATEST ISSUE) ON1HOOD EXHAUST FANS AND GAS FIRED APPLIANCES. tFEREFORE, THE ON/OFF PANEL AND MASTER RELAY PANEL. ARE TFE MINIMUM REQUIRED EQUIPMENT NECESSARY 11.ALL DOVETAILS INSTALLED IN A/C DUCTS/PLENUMS SHALL HAVE A VOLUME C(NT(R[>< TO MEET CODE. DAMPER. 12.AIR CONDITIONING CONTRACTOR SHALL COORDINATE DIFFUSER LOCATIONS WITH THE PLUMBING CONTRACTOR REFLECTED CEILING PLAN. 1. THE PLUMBING CONTRACTOR SHALL PROVIDE & INSTALL FLUE GAS EXHAUST VENT FOR HOT 13.THE AIR CONDITIONING. CONTRACTOR SHALL FURNISH A WRITTEN GUARANTEE COVERING WATER HEATER. A ONE YEAR PERIOD FOR ALL PARTS, LABOR AND SHIPPING COSTS, AND AN ADDITIONAL. 2. PLUMIBING CONTRACTOR TO PROVIDE & INSTALL CONDENSATE DRAINS FOR ALL A/C UNITS FOUR YEAR PERIOD FOR THE A/C COMPRESSOR AND HEAT EXCHANGER PARTS. ACCORDING TO LOCAL CODE REQUIREMENTS" 14.THE AIR CONDITIONING CONTRACTOR SHALL, UPON COMPLETION OF PROJECT, PERFORM 3, PLUMBING CONTRACTOR TO COORDINATE PLUBING VENT STACKS WITH OUTSIDE AIR INTAKES A COMPLETE TEST AND BALANCE OF ALL EQUIPMENT. REFER TO SECTION! 1691,00 OF OF A/C UNITS & SUPPLY FANS. MAINTAIN AT LEAST 10'-0' MIN. CLEARANCE OR PER BUKa KING SPECS. BOOK FOR TESTING FORMS AND PROCEDURES. LOCAL CODE REQUIREMEENTS. 15.WFEN WELDING STAINLESS STEEL(OR GALVANIZED) EXHAUST DUCTWORK, USE EVERDOR 4, PLUMBING CONTR. SHALL PROVIDE & INSTALL GAS SHUT-OFF VALVES FOR BROILER, FRYERS, RODS o 3/32' AND CARBON ROD A.G. HOLLOW CENTERS o 3/16'. AND BREAKFAST HOOD (WHERE BREAKFAST HOOD IS USED.) 16.PROVIDE DUCT MOUNTED SMOKE DETECTOR FOR IN SUPPLY PLENUM FOR A/C UNITS WITH OVER 2000 CFM OF SUPPLY AIR. FIRESTAT SHALL BE PROVIDED FOR ALL OTHER UNITS. SEE BURGER KING SPECS BOOK FOR MANLF-ACTIJM' MODEL NUMBERS. 17.AIR CONDITIONING CONTRACTOR SHALL FUFNISH MASTER RELAY PANEL AND CONTROL PANEL. REFER TO MASTER CONTROL SYSTEM SHEET. 6 N ,ER I CONTRACTOR •TOR 1. THE GENERAL, CONTRACTOR SHALL LOCATE, CUT, AND FRAME ROOF OPENINGS AS SF10WN FOR ALL AIR CONDITIONING EQUIPMENT AND EXHAUST FANS. SEE ROOF FRAMING PLAN. 2. IT IS VERY IMPORTANT THAT ACCURATE MEASUREMENTS ARE USED 'WHEN LOCATING EXHAUST FAN ROOF OPENINGS TO INSURE THAT NO OFF -SETS ARE REQUIRED IN THE EXHIAUST DUCTW%X FROM THE KITCHEN HOODS. COORDINATE ROOF OPENINGS WITH THE KITCHEN EQUIPMENT PLAN AND EXHAUST HOOD PLANS. OBTAIN THE CORRECT PLANS FROM THE KITONEN EQUIPMENT SUPPLIER. 3.AIR CONDITIONING ROOF OPENING SIZES AND ROCS CURBS ARE BASED ON CARRIER 'GAS HEAT' EQUIPMENT. IF ELECTRIC HEAT IS REQUIRED OR OTHER EQUIPMENT IS USED. VERIFY ROOF OPENING REQUIREMENTS. : OR ICEMACHINECONDENSER NOTE EF EXHAUST FANS 1 & 2 SHALL DISCHARGE 40' ABOVE FINISHED ROOF OR AS PER LOCAL CODE REQUIREMENTS. FIELD VERIFY EXACT LOCATIONS OF EF-1 & EF-2 W/ KITCHEN EQUIPMENT SUPPLIER. EF-1 - GAS CONNECTION (TYP. EACH A/C UNIT) REMOTE CONDENSING UNIT FOR COOLER & FREEZER BY OTHERS oL--J L- J PITCH FOR FIELD POWER SUPPLY CONNECTION FUTURE (TYP. EACH A/C UNIT) EF-2 ANTENNA FIELD CONTROL WIRING CONNECTION NOTE: O (TYP, EACH A/C UNIT) MAINTAIN A MIN. OF 10 ' -0 " CLEARANCE FROM ROOF SCUTTLE -- / ANY EXHAUST FAN TO ANY FRESH AIR INTAKE. r L - J • d EF-3 A/C-4 ALT. REMOTE CONDENSER FOR SODA FACTORY RETURN AIR DIFFUSER MASTER RELAY PANEL/ CONTROL PANEL (44' A.F.F. MIN,)' DIFFUSER OR GRILL NUMBER CFM A/C UNIT OR FAN NUMBER ROUND FLEX DUCT ROUND METAL DUCT AIR BALANCE SCHEDULE UNIT NiUBER RETURN AIR OUTSIDE AIR EXHAUST AIR MAKE-UP AIR A/C-1 1375 825 A/C-2 1375 625 A/C-3 1775 625 A/C-4 1775 625 EF-1 1000 300 EF-2 1350 EF-3 350 TOTALS 6300 CFM 12600 CFM -2700 CFM +390 CFM- BUIL.DING POUSITIVE PRESSURE " +100 CFM = E 1.3 ,x 5 x p ur , • p_ tir 0 to v's p �wx ¢„ Ix cc O� F co a E INGtUU 2D DUCT SMOKE DETECTOR (SEE NOTE 16) j 3 KW OPTIONAL DUCT HEATER EIEI ( ZONES A & ' B ONLY) OUTDOOR 'WALLMOUNT GRILLE .: DIFFUSER SCHEDULE '. SYMBOL NECK SIZE TYPE DUCT CONNECTION SI MODEL NUMBER FINISH (f_ : OPENING REMARKS QTY BOOTT SIZE FRAME TYPE _ZE ; 1 15xl5 SUPPLY 4 WAY 12'm 5000-MG-S4 ALUMINUM 16X15 T-BAR 6 U_ 2 12X12 SUPPLY CUM 8'm 5000-MB-sC ALUMINJA 12X12 T-BAR 1 3 T 12X12 SUPPLY 3 WAY 10 5000-M6-S3 ALUMINA,L 12X12 T-BAR 1 4 6X6 SUNNILY 1 WAY 8'm 5000-M1-S1 ALUUMINUd 6X6 9.3/4' SO. 2' 1 .'cl 6 1OX10 EXHAUST 8.0 TRH ALUMIPAM tOX10 10 R/4' SQ. 4 _ a, 6 6X8 SUPPLY 1 WAY 610 5000-MI-Si ALUMINAM BX$ 9 3/4' SO. 2 7 24X24 SUPPLY PERFORATED in 7500-6 ALUMINUM T-BNR ED t 8 12X12 SUPPLY PERFORATED 7500-6 ALUMINUM INCLU)ED T-BAR 4 s: 9 2024 RETURN 18''D GC-5R- TB ALUMINUM W22 T-HAFT 4 ` HVAC ROOF PLAN 1, SCALES 1/8'•1'-0" is0191yorall S sk 07,11.17111 i • 1 1• r�:E s • r; i k t i i 1 1 �x 1 f e'. �r > 116 v. ..'Icy, .. .. .. ... .l , s'•n. .{ :.._ , .. .. .«r- .. Yt J • '-i _ . a f :_ Gf' R.. ,*, .:•1 ,t � .. ..1 •.:t� f 3r I0184 ... 3-- ... ... ...., .. _. .. r.. t#. .. .r .... . _ 3 z. .. .. � 1..-.. >s.<;. .. ',. c,. .'Y.P 5t i ,eG. .• F•32 •[' - f 4 - .., s. ,. ... .. ., _. -. .. _ �� 2. t..: -' r ,•-:e%- 3. �•i _ ,� x . .. -. r _. C' r • _. , c ,-...:.: a k �a.. Odra Ia ... � .. S ',' .<. N .. s J d. i .`. 1.•F.. f•k*' �t .£,-_. J s .t F. +.+ ..L,n r. ,o n:. .. .. • .. .. �. .k w. �. >7='rx .fi _ ., e a_ , :. ,. .. .. •. ._ .. ._ r xt. .tR 1 , � ;•. Y .. 't, .. .. .. _ f P ^'i .. p:, { {'.'� .,h !.x S^^. .. f', •h.}'r t <'�f ,1 i:. >.. '4. _ ,> r i• r. p. L. .. ,+..Gt- k... 1i[ _-_,,.... ->.< ., - :? :�+° i"it _.: z "''� ,]. .,d.. F4, �., 5• �,_.{ r � 'P , +. k .... .-< _.. 4 . i .. ,+r ,. ._ < s _ _ •' -F,r b { r '.3�� .7 �.: tx �.+�' 1 . s. C.:s° S ., e _s ,,. G. .. i. -t. .. w 3. s ., ,... :. � } .. .. e ._ ra._- .. .-3 4 >'�• ¢,�.. Y, .. •.-c ';�.r 4 x .'�' u n .Y.,... � .x-..,..., .,+._ ,•' S' ... k.#.. � f r �- _. -�. a r - _. `4 a t•• ,. 7...3 ,. .-.. `i..... i, .' x. .. _ ,.. >.. , .:�•e.: _9 1'r r.+ s d. .,�. .. r. a � d , a ✓ _-# Y �. Y, f s _'D ,n a, ::'��� .aJ_•_ ,s r- t _< 'i . .. .i, .. .� R-�„r...., ... -.• o.- .t ,,.,...: �. a ..� fir. e-a. =r .L rt. t .- •i .. C•_ s. � ,:> : <, .//r y. + r r., Y, ±4x, �. d.. .-I. �.a �. } }:Yrti " r.r.-.. .t. � '. ,-.a f. �'' �' ., .. ,•n. ...t....r ':.: r P "•'.r -'. �. .. _•Y' I l..a x �' 2'° .:#-... t, r....,- ,.-.n�,!:,,, . .^r,+.r.«-✓, .'rfi-.,s. .t5, :,G..F.. �:.Y.T.;:.r<eY >n� rr4,t'-< ^,.�. ., .r: �..,i DUCT INSULATION HOOFING CON r ' R , SUPPLY AIR PLENUM FLEXIBLE INSULATED DUCT (TYP.) SIZE VARIES. DOVETAIL WITH DAMPER (TYP.) ' ROOFING (SEE SPECS.) \ - PLYWOOD DECK RETURN AIR PLENUM — -- — (SEE DETAIL BELOW.) WOOD TRUSS CLASS I FLEX DUC,r (TYP.) TYPICAL SECTION THRU STANDARD CURD SCALE: 3/4' a 1'-0' NOTE: REFER TO SHEET S-2 FOR EXACT LOCATION OF TRUSSES. 32' 2' 1211 13Y" 24 GA. MIN. GALV. SHEET METAL I. I 14" 14' -+- — — — — — I -- '* RETURN AIR PLENUM — — CURB ADAPTOR FOR { CARRIER UNITS. 26' TO BE SUPPLIED W/ " 1183� I CURB. RETURN AIR PLENUM ADAPTOR PAN DETAIL SCALE: 3/4' - 1'-0" y r F. DECK INSULA PLYWOOD DEC B/ D( W( TYP. SECTION THRU ALTERNATE PLENUM CURB TYPICAL A/C UNIT MOUNTING SCALE: 3/4"=1'-O" (NOTE: REFER TO SHEET S-2 FOR N.T,S. ` EXACT LOCATION OF TRUSSES.) / t{Agg 5"x7" CUT -OUT WITH GASKETED COVER, J NOTE: PROVIDE VENTED COVER `Js ONLY IF REO'D . BY LOCAL CODES. A/C UNITS ROOF CURB SCHEDULE MANUFACTURER UNIT SIZE Q L�DDEL NO, DIMENSIONS ROOF OR A B C REO'D.. 1 REFER TO MA UACTU ER'S 5 AND 6 TON 50DU900771 67 3/8' 37 3/16' 14' 46' X 37' DATA CATALOGS/SPECS FOR \ CARRIER INTERIOR CCPFIGURATICN 10 TON 50DJ901371 78 1/4' 50' 14' 55' X 47' OF CURB' I� \ rRAr� �5 TON BNACUM1A 73 518' 39 3/8' 14' 48, X 39, U 6.25 TON BNACURB202A 78 5/8' 42 3/6' 14' 52' X 42' 5 TON IRC0427 69, 33 1/414' 44' X 33' i YCPoC WOOD NAILER \ 6.25 TON IRC0427 69' 33 1/4' 14' 44' X 33' + 5 TON RLF16-65 69' 46 7/8' 14' 49' X 25' LENNOX 6 AND 7.5 TON RW16-95 87 1/6' 46 5/8' 14' 54' X 32' P TROPIC-KOOLl 5 APD 6 TON TKECURB © 67' 37' 14' 67' X 37' `(i) WHEN CONCENTRIC DIFFUSER IS USED IN EXPOSED DINING ROOM. ROOF OPENING TO B BE LIMITED TO THE SIZE OF DIFFUSER CONVERTER BOX. GENERAL CONTRACTOR TO \ VERIFY OPENING SIZE 'WITH HVAC EQUIPMENT SUPPLIER. ( TFF ALTERNATE AIR CONDITIONING PLENUd L41IT ROOF CURB IS PROTECTED UNDER PATENT RIGHTS (PAT. 04, "403, #481) AND CANNOT BE WJUFACTUNED WITHOUT PERMISSION FROM THE TROPIC-KOOL ENGINEERING CORPORATION. Q3 CONTRACTOR TO VERIFY REQUIRED SIZE WITH PACKAGE A/C UNIT SCHEDULE. ytE yj i�fT y •T'h � t r�• �'7�F%: 4 i 'C • r ,.p 1 . - s ... f , ., • .. .. n r ,,. £' ., .. !'- `,Z ,. F T 2' r . < F a- 4 rs o. ..... . ..t• : .. h., ... ... "t.,v .G. a Y,f . l v .,. f Y~. ♦ r. +� e'w" _r.. - i a o .. _ .. �: .. !. X a.. / n r.�' } ,w f .. 'f. • M. ' ti.. M1 � r. .. >>,�} r. e ♦ _ , ,s 4 .. .. .. .. > ... ,.. •. .r. ,. �. b. .. : of r,._ ram. 'tA. , < �.. 4 ,.f.. r _�' F >�. .. � .: a.. ?i 't ) ✓!� , � .. �y �/�. , .. ♦ . . .+. 'a. ,.,.. .n .x t "it S F, .!i < t,. t•£t. ,f r1, - . r _ •.. � ,•... ,r v s 5. w .r,. .. ..a.. .. > .. r. � •.. - , -:... S .. ... -� . -� .. �.,. .- i., �. $ W ,,.. .4. A ..rr .•Y.ei k 4. F �1#. ,•, . .r`. ,�. , r �. ... . ,.,. , .. , r .. r <. s r a• � ,.. . , 's+ .r. .. �... _.... .. � .i '�. .. u�'... ,. .. a.. .S `F _ .. ,. 'e ,•}f` _. .. t.3., �,- .,r. .. ,. •kz. .... � 1 r.. _1, r.. r.. .. h. F s ::. '# 1.. ...Y :°4 _ ,. :. .. r . .... t r.- _ :'.+. ... ..a':A ti,,. ... ?� n S a r.. a'*w • r:. qy _: t �...� *-.-3•?J;+j¢ e 4 .'l, n'.}te.N- t a" s „! ..a. s,.,, >� .,r �W .X. ♦ , v , }` t {'t ' . r.. � . �T S F E i:f .... .4 .. ., ,r 9 R .: ♦ ,. . . .,. h ... .� ,. ,.. � ...-.x •L -e L M ^'i .- t _ J_ .:•- r. -.'' ih { i x "t'• .. .. .i = Qtizw x'd33 >3 � .,. � ♦ ..tt 1� .. V`,. .x ,. ,.. ... .. r ,. .n.. ,i�. .w.':"t... -.; ti.. . i a. . �' . : Y *aF s.. .-s ... at .. xa,{., . .,. _�...-..1� .. it ♦ z.x,....[.1...,,,.,...,'�,.�>k->..e:m,....x,,..t.�.:�..,_,.r,k',::=rr,.__.:_ i��_......"?r�:._r,. .:,r=sx:'d:..rt,,.rt,rt n� ,f!c�•,.xr!r:,, %4u'I/L•IYJnit- PHOVIDEU B'f . e : tj -! — - — PLUMBING CONTR. SEE NOTES 11 AND 12 a •tea d 1 II II I I I II ! • � 1 I I L Pff 4' LAV. M1•�,. I ^ NO HANDS W.C.O. SINK W.C.O. 3' F.Q. Ci / 1 2. 31. 4 • i � � � � 3' � � FOR CONT. SEE GREASY WASTE � � 1 RISER DIAGRAM r� L W LAI/. I -3- 3' F.D. � . c . I I SALAD PREP. SINK UI.0 F.C.O. HALL y C.. 1 SAN I TAR`( WASTE RISER D I AGRAM SCALE: N.T.S. ---- ��� ► F.��o. � PLUMBING37.8. I �FLOOR PLAN MAC I � � G(SANITARY AND • GREASY iVAo_E 3' 4• 1 SCALE: 1/4"=1'-0' Cy I 3• I • W.C.O. 3'F.D. 3' �J G�► NOTES 3' V.T.R. 4' 1. PLING CONTR. TO COORDINATE VENT STACKS WITH OUTSIDE AIR INTAKES [ 3-COMP, LMBCF A/C UNITS AND SUPPLY FANS & MAINTAIN AT LEAST 10 ' -0' WIN. CLEARANCE . (SEE NOTE 1) ���I� ROOF am • STEAMER ,� E `'. _ CR AS PER LOCAL CODE REOUIRB&ffS. G 2 INCREASE V T R 'S TO SIZE REQUIRED BY LOCAL CODES AFa tx Fj x 4 a- • CONUI iIONS 1 3'F.S. AS REQUIRED FOR FROST ENCLOSURE. - 1 3• PROVIDE 2' COPPER SAFEWAsTE LINE FROM SODA FACTORY TO FLOOR DRAINS. _ 13'F.D . GA 4. RUN SYRLP LINES FROM SCOA FACTORY TO DRINK DISPENSER ABOVE CEILING. 5. PROVIDE SAFEWASTE LINE FOR HOT CHOCOLATE AND TEA DISP&C-a IF REO'D. =a I 3 , 2' LOOP VENT FREEZER Ip FOR CONT. SEE SA71AQRAYM ABOVE CEILING v 8. PROVIDE CONDENSATE LINES FROM A/C UNITS ABOVE CEILING ACCORDING RISER D3' V.T.R. TO LOCAL CODE REaJIFiEJ/FNfs.� 1 (SEE NOTE 1) 7. RESEAL FLOM DRAINS ACCORDING TO LOCAL REQUIREIENTS. � f✓ 3 HUB 8. SAFEWASTE PIPING ABOVE AND ALONG FLOOR SHALL BE SIZED IN ACCORDANCE WITH LOCAL CODE REQUIREk&ffS. II ROOF �4LEf3 9. COORDINATE SAFEWASTE LItF- COt4NECTIONS WITH EQUIPMENT ROUGH -IN. J 4 ' RO . (663.50 al ; X.C.O. 4' 3' 1 1%4' COPPER CONDENSATE 1 `10. P.Y.C.(SCHEDLLE 40) PIPE CAN BE USED FOR VENTS Anil WASTE ONLY IF LINE PROVIDED BY PLUMBING �I 4 RO . (663.50 (] — —�- APPROVED BY LOCAL BUILDING CODES, SEE SPECS. FOR ADD'L. INFO. f% C� CONTRACTOR. SEE NOTES 11 & 12 4 of/4'/FT. 11. SEE FOUNDATION PLAN FOR EXACT LOCATION OF FLOOR DRAINS AND FLOOR SINKS. C� 3' I ,,� 12, IF VALK-IN-BOX CONDENSATE LINE IS REQUIRED BY LOCAL CODE,13` •� Tl I PyL 4 0l /4 /F f . y PLL&I31N1G CONTRACTOR SHALL FLRNIISH AND INSTALL 1 1/4' C%UENSATE 2' - LINE, AND SEAL ARMU ALL PENETRATIONS THROUGH ffE WALK -IN -BOX. 4' RD. (663.50 (;!1 4'o1/4'/FT. H 13. HEAT TAPE IS PROVIDED BY WALK -IN -BOX MANUFACTURER AND P NSTALLED BY ELECTRICAL CONTRACTOR. IT IS TO BE SELF-LIMITINU fi INDIRECT WASTE LINE �w I TYPE. ' ROSTEX' OR EQUAL. FROM SODA FACTORY 4' AD. (663.50 �p P THRU WALL. w W.C.O. 3'F.D. 3'F.D. t 5' 3. • ru THRU CURB TO PAVING GREAS`r WASTE R Z SEA DIAGRAM _ _ _ RAIN WA TER D RA I f�IAGE RISER DIAGRAM k kl �Y SCALE N.T.S. SCALE: N.T.S. (SEE ROOF FRAMING PLAN) 1 � k l • INY f 1. , r f : i Z- 12y A.F.F. 48" A.F.F. . . W SELF -SERVE COFFEEICE DRINKS °o MAKER 1 DRINK� Z. 3-COMP. o D T SP . SINK 1--__---_._:-.r-----_ C C C °� I /A� I'I 3/4" LINE ABOVE CLG. - F CF r. .a 4zx I TO HOSE BIBB W/VACUUM I UP (0 I o>'7? i BREAKER AT FRONT'OF BLDG. II I STEAMER BROILE A/C UNITQ j TO GAS SERVICE • BELOW GRADE A/C UNIT "4 MANUAL GAS SHUT-OFF I I �- I 1: i p z.� GAS METER RIG. VALVE IN '!TALL BOX I _ _ �-Z (60 A.F.F.) r ROOF I I I I I sa GAS SERVICE x :. I GRADE 2 1/2' 3/4' r- — — — — — -� — — —ABOVE ROOF I I I G 1`1 G i I I I i I I 1 vj m 1• / 2 1/2' WATER HEATER I A/C-1 ' I A/C-2 I i( I HOLD I NG G 100.000 BTUH I I I ' CABINET-_ �— GAS METER' 1 L — — — — — J L — — — — JZ - (I UP TO MAIN SHUT-OFF VALVE 1 MECH. GAS SHUT-OFF RAF CF I �' MANUAL SHU70FFVAL VALVE ABOVE CLG. 2, G �� ,p �`� G G i 1 G 1 FRYERS I VALVE (60' A.F.F.) z z , (SEE NOTE 9 THIS-� SHEET -TYP) BROILER SEDIMENT 1--�� WAL ,o° I I - I - I - GROUNDC °.GAS SHUTOFF 96,000 e TRAP (TYP) •CF G VALVE BTU/HR 1' ROOF I I I i 2 1/2" 1 1/2' 1 1/4' I I 1 ll �/ I G �. G G A/C UNIT 43 1 1/4' c' G 140cl 1 1/2' 1 II II 2 ° y VEG. CD 6, ° �, N HANDS PREP. ROOF a 1 I I{ utr,. S I S T NK MOP `I A/C UNIT 42 SINK 1' 1 1/2' _._. -_.. 1 I I GAS. A%CTUNIT ° r �- -► � � ; NOTE I i/ I r Q A/C UNIT "1 1' (TYP) FOR A/C UNITS BTU/HR �v C/C REQUIREMENTS REFER TO r 4 4 SINGLE POT SHT. A/C-1 SCHEDULE. SODA FAC DORY I FRYERS 122,00 BTU/HR -EACH BREAKFAST GRILL 'j - - - CF CF_ (BREAKFAST GRILL o W.C. �c w. t,� C 82,500 BTU/HR) 1 1/4 ' ���� . 120 ° 140 ° WATER FILTER LL a _. �. V- ILING MIXING VALVE c SYSTEM (OPT.) GAS RISER DIAGRAM c ! ----� � 1.au. �) i � SEE NOTE tt10. , SCALE' N.T.S. • LAY. _.140° 3/4 H.B. WITH W. . _ C C VACUUM BREAKER WATER HEATER Ulow, 1 1/2" TO LAWN SPRINKLER SYSTEM (PROVIDE SEPARATE I © CCox PLUMBING ��OO� PLAN METER WHEt`J ALLOWED' BY CODEI L1 IAAIN C.'�(. SHUT-OFF VALVE SCALE: 1/4'=1'-O" (GAS, HOT AND COLD WATER) Z 2'r`- W x r) N CIE 3/4' ��, 1 1/2' WATER METER 'R r�I PROVIDE STUB -OUTS FOR OPTIONAL WATER FILTER SYSTEM FURNISHED SHAKE -MACHINE PLUMB. CONN. 1 1/4' BY EQUIP. MFR. MOUNT -TOP q y� y� y� �} /� I✓ t r `(,�^t�j TR�iI �l^� Tuts 1�F `.0 too 1/2 " 3/4 r OF FILTER MANIFOLD �' t / r, 2° S�PERATE CF LINE 8 -0 A.F.F. t AIE,'P, c�11 � `/ ` c �r}A.',aJ;. t-ioT �� cow -id�� �O C' TO SODA FACTORY 4' 0 FLUE THRU ROOF, m W/ VENT CAP TO -iN . EjG?t l t�. bye--j TE:lA A`� ,A PiRt_l0T VtIA ST'E � �x "�o-R°°►. ICE -C3 OMP. `\, 1' ELECTRIC GRND . -- SODA FACTORY MAKER SINK �c .� 3l4' C' \ 1 1 /4' 36' HIGH mv�q�-4.. " `� 1 1/2' 3/4' 1/2 i1 i� • `\ I ' �c / ROOF VEG . PREP . `o SHAKE MACHINE - 112' \ SINK I \ \ \ _ 3/4' - � �� �C/ 4°�b VENT - /to I � NOTES — \ V 1/2' xG 1. STEAMER "'/ • 3/4 3/4' NO HANDS .OFFEE SINK 1/2' HOLDING DRINK `• D ISP . SELF -SERVE DRINKS {3/4' LINE ABOVE CLG. TO HOSE BIBB W/ VACUUM BREAKER (TYP) CABINET 1/2' c\ 3/4' i 3/4' l2 ° � \i �J � LAV c.� W.C. LAV T MOP 1 �Z G N SHOCK ABSORBER •� (TYPICAL) W.C. VALVEOFF (TYP) VACUUM BREAKER }- ------ ( (TYP) I 1 1/2' LAWN SPRINKLER SYSTEM MAIN SHUT-OFF VALVE 1 1/2' WATER METER 3/4' HOSE BIBB/ VACUUM BREAKER 1. DO NOT SCALE DRAWINGS 2. GENERAL CONTRACTOR AND PLUMBING CONTRACTOR SHALL VERIFY GAS REQUIREMENTS OF THIS PROJECT BEFORE BIDDING AND PROCEEDING WITH NOW. SEE SHEET A/C-1 FOR GAS REQUIREMENTS OF A/C UNITS. 3. ALL HOT & COLD WATER PIPING LOCATED ABOVE CEILING AREAS BUT BELOW ROOF INSULATION SHAD. BE INSU..ATED WITH 3/4' FIBERGLASS LOW PRESSURE TYPE WITH DUAL TEMPERAPURE JACKET. ALL HOT MD COLD WATER PIPING LOCATED OUTSIDE OF BUILDING INSULATION ENVELOPE SHALL BE INSULATED TO THICKNESS SPECIFIED IN INST,LATION SCHEDULE SHOWN ON THIS SHEET. ALL. UNDERGROUND PIPES LOCATED INSIDE BUILDING TO BE ENCASED IN FLEXIBLE POLYETHYLENE. 4. LOCATE C.W. PIPES IN FUIRED OUT SPACES AT TOILET RMS.-ZONES A&B (ONLY). 5. PROVIDE FROST PROOF HOSE BIBBS IN ZONES A,B,C & D. 6. PROVIDE SEPARATE SHUT-OFF VALVES FOR ALL EQUIPMENT REQUIRING WATER CDIINS. SEE EQUIP. SCkEDUL & SERVICE LOCATIONS IN SHT. EQ-1. 7. PROVIDE COUPLINGS TO ALL EQUIPMENTf AS REQUIRED. 6. PROVIDE 1/4' DIAMETER AIR LINE ABLE TO WITHSTAND 608 PRESSURE TO RUN OVFFrtEAD FROM SODA FACTORY DOWN TO TAYLOR 5454 SNAKE MACHINE. 9. FILMING CONTRACTOR TO FURNISH & INSTALL MECHANICAL GAS SHUT-OFF VALVES FOR FIRE PROTECTION SYSTEM. VALVES CAN BE OBTAINED FROM THE FIRE PROTECTION SYSTEM UPPLIER. AN✓SI.L P/N-56W7-1 1/2'. 10. PROVIDE 4'0 FLUE VENT TYPE'B', SHEET STEEL 16 GA. LAST PORTION OF PIPE SHALL EXTEND A MIN, OF 36' ABOVE BUILT-UP ROOF. 11. PROVIDE BACKFLOW PREVENTTCR ON WATER LINES WHERE REQUIRED BY LOCAL CODES. 12. PROVIDE WOOD BLOCKING AS REQ'D. FOR FIXTURES AND PIPING. (SEE SHT. A-1.) 13. CONTRACTOR TO PROVIDE 3/4'tO HOT AND COLD 'HATER LINES AT TRASH ENCLO&M N/ MIXING VALVE AT CAN WASH INSIDE OF BUILDING. 14. THE PALOMA 6DL."24MDN INSTANTANEOUS GAS 'HATER HEATER 15 NOT RECOMMENDED FCR USE IN EXTREMELY COLD CLIMATES (Z%E A) DUE TO ITS INABILITY TO PRODUCE LARGE QUANTITIES OF �OT WATER Oft MAINTAIN WATER TEMPERATLRES IN EXCESS OF 130 F. LC,VCINU ►----- C COLD WATER 0 CF COLD WATER FILTER SYSTEM �---- 120° HOT WATER (120°) ----- 140° HOT WATER (140') G GAS PIPING GATE VALVE G --- G --- GAS SHUT-OFF VALVE ' CHECK VALVE HOSE BIBB W/ VACUUM BREAKER G _ .. MECHANICAL GAS . ---- G--Q---- G - SHUT-OFF VALVE 0- 4 GLOBE :VALVE INSULATION SCHEDULE,,",., ZONE PIPE SIZE. UNDER 1'DIA. PIPE SIZE OVER 1DIA. AW 4' THICK 3` THICK C 3'.THICK' 2' THICK. O&E -3/4' THICK 1' THICK 4a� i ' a 1'A �' :��-{ 2 �� � IJ�3„R �".31'T,•.r;�P S �' .� 3 44 r ii f{� F�. !V^ "'� Y"'C }.lam :.'SJ fi r �k�� i� f d>. t'•�e .1 3 . }Yr ,y /y'-t k- + '�,�t+-�t - h_�'1FT+ ST3.�. }lii,&i I?t.r�aY.--3�•ti�.. J: 7; s r y i fA!� SYMBOL. LEGEND" SYMBOL DESCRIPTION FLUORESCENT LIGHTING FIXTURE Q A-1 INCANDESCENT LT. FIXTURE (CEILING MT'D.) WIRED TO PANEL 'A' CKT. 1 FQ, INCANDESCENT LT, FIXTURE (WALL MT'D J CONTROLLED BY SWITCH 'a' Eno EQUIPMENT/SERVICE CHASE �+ LIGHTED EXIT SIGN - CEILING & WALL MT'D. - PROVIDED W/ BATT. PACK O LIGHT FIXTURE TYPE 'A' - SEE LIGHTING FIXTURE SCHEDULE L:J PADDLE FAN - SEE LIGHT FIXTURE SCHED . FOR SPECS. $ a SINGLE POLE TOGGLE SWITCH (20A, 125/27M +48", SWITCH 'a' $2 DOUBLE POLE TOGGLE SWITCH (20A, 125/271V) 448". $3 THREE-WAY TOGGLE SWITCH (20A, 125/27711) -48" $4 FOUR-WAY TOGGLE SWITCH (20A, 125/277V) +48" $P SWITCH WITH LIGHTED HANDLE WHEN -HANDLE IS IN THE 'ON' POSITION IT IS LIT $F FAN. DISC. SWITCH (FURNISHED WITH FAN CONNECTED BY CONTRACTOR) $ M MOTOR RATED TOGGLE SWITCH WITH HEATERS (MANUAL STARTER) $PR TOGGLE SWITCH WITH PILOT LIGHT FURNISHED PRE -WIRED WITH WALK=IN REFRIGERATOR/ FREEZER $ ST MAIN BREAKER SHUNT TRIP, BREAK GLASS STATION - ASCO OR EQUAL. (FOR FIRE FIGHTERS DIS. WHEN REO'D, BY LOCAL CODE AUTHORITY -) - SC CONTROL SWITCH FOR STOCK LEVEL SYSTEM PROVIDED BY FIXTURE MANUF. H R WALK-IN REFRIGERATOR/FREEZER DOOR HEATER, PRE- WIRED IN DOOR FRAME h R, WALK-IN,REFRIGERATOR/FREEZER WALL MOUNTED LIGHT PRE -WIRED IN WALL COORDINATE LAMP WITH SUPPLIER DUPLEX RECEPTACLE OUTLET, 20A, 125V, 3W, SPEC. GRADE, WALL MT'D., -18" DUPLEX RECEPTACLE OUTLET, 20A, 125V, 3W, SPEC. GRADE, CEILING MOUNTED SINGLE RECEPTACLE OUTLET, 20A, 125V, 3W, SPEC. GRADE W.P. INDICATES "WEATHER PROOF" R.T. INDICATES "RAINTIGHT" E.W.H. INDICATES 'ELECTRIC WATER HEATER" INDICATES "GROUND FAULT INTERRUPTING" DEVICE FG.I. .P. MASTER RELAY PANEL (SEE WIRING DIAGRAM) C. EMPTY CONDUIT NL NIGHT LIGHT - UNSWITCHED ® SPECIAL PURPOSE OUTLET -TO MATCH EQUIPMENT PLUG Q Q-J JUNCTION BOX -CEILING AND WALL LJj PRE -WIRED J-BOX IN EQUIPMENT - SUPPLIED BY EOUIPT. MANUFACTURER PREWIRED OUTLETS BY EQUIPMENT MANUFACTURER {� TELEPHONE OUTLET Pe PUSH BUTTON - EDWARDS "B52 B[J{ BELL - EDWARDS -17-4 ❑T TRANSFORMER - EDWARDS "99B © CLOCK OUTLET DUCT STRIP HEATER WITH DISC, (FUSED) SWITCH & CONTACTOR -SIZE FUSES AS PER MANUFACTURER'S DIRECTION MOTOR - CONNECTED BY ELECTRICIAN ® MOTOR STARTER -.MOUNTED AND CONNECTED BY ELECTRICIAN 6o HEAVY DUTY SAFETY (DISC.) SWITCH: 3=3 POLE: 60=60 AMP: F=FUSE SIZE AS DIRECTED BY EQUIP,MANUF.(FUSED IF REQ'D. BY CODE GOVERNING AUTHORITY). �-Q JUNCTION BOX ON STUBBED UP CONDUIT DISTRIBUTION PANEL OR GUTTER LIGHTING OR GENERAL.PANELBOARD Q EMERGENCY BATTERY LIGHT/REMOTE HEAD (WALL.MT'D.) t---- BRANCH CIRCUIT HOMERUN TO PANEL �ivvv� FLEXIBLE METAL CONDUIT CONDUIT RUN CONCEALED IN WALL OR CEILING — — — CONDUIT RUN UNDERGROUND, IN OR BELOW FLOOR SLAB B \\ CONDUIT RUN CONCEALED, TO VIEW, ABOVE EXPOSED WOOD BRIDGING AND PAINTED TO MATCH WOOD —DC— DIRECT CURRENT WIRING (12 V. ) SD DUCT SMOKE DETECTOR -FURNISHED & INSTALLED BY H.V.A.C, CONTRACTOR SELF -POWERED (24V) TO SHUT DOWN A/C UNIT UPON SMOKE DETECTION. -� SMOKE DETECTOR ALARM PANEL FURNISHED BY H.V.A.C. CONTRACTOR 48"A.F.F. PROVIDE IDENTIFICATION ENGRAVED PLATE OR SIGN. 2 - 1'(V E.C. FOR (,• .a 24' — - COMMUNICATIONS SYSTEM. 2 - 1 E.C. TO BASE II OF D/T. ORDER STATION FOR 10 I D/T COMMUNICATIONS SYSTEM 54.(rt 3$E 8- 4 B-25 B-2 A.F.F. a " AF 4 a Y: 13,15 p B-17 19 _48" 14 o(t .� B-1 -8 8-8,10, 13,15,40 — �iOTE�[]5 rl =" B_4 C-2 , 4 , 6 NOTE ® POWER & CONTROL FROM o . z C-8,10,12 REMOTE ( REE (SEE NOTES & © ) NOTE 4❑ o B. 0 , I .. g-9 DISC. (TYP.) r �N 1- 2 I 1 (TIE) PANEL "D" r i, D -12 ,14 SEE NO 14 FREEZER to Q REFER TO SHEET E-5 FOR I I I J rD 17 �,, _9 , 1 �-� EVAPORATOR/BLOWER (TYP .) ; P.O.S. SYSTEMS ELECTRICAL -- D -16.18 , INFORMATION . 1 I A . F . FI. D 5 , 7 8 +7 13 "' Q 0 II 1 B-�2, SEE NOTES fi 4 r ,�J, I WALK-INBOXES z 3 LJ�— , 0&0 B-30,32,34 �`-NOTE 6❑ W • I .B B. (TYPICAL) NOTE 1I 1 8-14 I -30,32 i g- ,a5.37 _, r POWER & CONTROL FROM REMOTE ROOF B-16 -3 ,� �I 1 L COOLER REFRIGERATION UNIT ON 0 i -3 �� I (SEE NOTES 11 & 1[ D J 24 - 3 , 37 f, ll - - B- 7 _ OT1�`I3.6 , 38 , 41 POWER CO. DINING ROOM I -2 31.( METER, SEE II B-12,14,2 ,A, B, rC. ,Ml N' RISER I SEE ! I B 33 NOTES 1' B-20 I B m & ® I 1 B-11 I( I L $-16,18,20 B-9 TIE NOTE 16 60" FOR REAR DOOR ALARM 0 II SEE NOTES T A.F.F. f s C 1 108" A.F.F. 48" A.F.F. _jj_ 2 48 " �s r 42' ' I I -. r> A.F.F A.F.F. 1` so' A.F.F. r �c TO MASTER RELAY PANEL. B-2,6 I I I/\ I G B-39 SEE SHEETS E-3 AND 'v-- LL B-26,2II 42" I/ \I C-20,22 PROTECQRONINFOSOEMFIRE M.R.P. 1 A.F.F C7 ry•1 ' C-9,11 M.C.P. A-18 NOTE 17 C-5,7 ❑ (NOTE ❑7 l C-15,17 C_3 48 " , . A.F.F' 36" A.F.F. a n F i5 � r L l } x� NOTE: ALL OUTLETS TO BE MOUNTED z 18' A.F.F. UNLESS OTHERWISE NOTED, r� wz r ELECTRICAL POWER PLAN SACLE: 1/4"=1'-0" EQUIPMENT NOTES �10° u► urn t � J�4IE_ 1 CONDUITS,WIRES & RECEPTACLES PROVIDED IN EQUIPMENT BY EQUIPMENT t- *Oct SEE SITE PLAN FOR BLDG. ❑ !A N-FACTURER & TERMINATED AT J-BOX PROVIDED INSIDE OF EQUIPMENT. to x *Oct . ORIENTATION ON SITE " ELECTRICAL CONTRACTOR TO RUN CONDUITS AND WIRE TiRU EQUIPMENT °: i r a�a142m x CHASE AND co"uT TO CIRCUITS PROV.IN Jcc -BOX BY EQUIPMIENT MAPU�F. EMPTY J-BOX AND SINGLE OUTLET INSIDE FRYER HDOO BY EQUIPMENT ❑3 MAN,FACTURER TO BE USED FOR CONtECTION OF HEAT BLANKET AND SHORTENING FILTER LOCATED AT FRY DUMP STATION. ELECTRICAL CONTRACTOR TO PROV.3 POLE 4 WIRE GROUNDED RECEPTACLE ® AND CORDS WITH PLUGS TO SHAKE MACHINE. (SJO CORD WITH 4#10-NEMA TYPE RECEPTACLE "L18-30R AND "LIO-30P PLUG). ❑PERMke1 LY CC",ECTED KITCHEN EQUIPME7'fr NOT SUPPLIED WITH CIN/OFF UNIT SWITCH (WHICH IS PART OF THE APPLIANCE) TO SERVE A5 A DISCT�tNECTINIG MEANS SHALL BE SUPPLIED W/ DISCONNECT AS PER N.E.C.-THE LATTER FURNISHED BY THE CONTRACTOR. F ELECTRICAL CONTRACTCR TO PROVIDE WIRING AND CONDUITS TO FECEF'TACLES OPT. WP OUTLET © FURNISHED AND MOUNTED IN WIREWAY BY EQUIPMENT MANUFACTURER. f 30" A.F.R. FOR -TV ! FOR MULTIPLEX & CWELIUS PROVIDE: 1- 120/205V 10.30A VIDEO CAMERA. RUN ❑ CIRCUIT (NEMA L18-3OR AND L18-30P PLUG). CONDUIT TO BLDG. INT., VERIFY SIZE & HEAT TAPE IS PROVIDED BY 'NALK-IN BOX MANUFACTUfER AND INSTALLEQ e ® BY ELECTRICAL wirRACTOR. CONTRACTOR SHALL COORDINATE INSTALLATION �� LOCATION W / OWNER. AND SUPPLY 120V CKT ." RECEPTACLE AS DIRECTED BY BOX MNUF . C- T � ^ � 'G 9 STUB -LP CGDUIT ADJ.TO RCCF CURB AND PPTN.SEAL IINT CCPt•ECTIQJ TO DISCU+ECT 'WITH SLFFICIINT SLACK TO AIffA FfrJd(NAL CF FAN FOR SERVICING. STAINLESS STEEL SERVICE CHASE TO CEILING FURNlISHED BY EQUIPMENT !' F1_01 MANUFAC TL) ER . CONTRACTOR SHALL OBTAIN WIRING DIAGRAM FROM V.I.B. MAMFACTLRER t1 AND INSTALL AS DIRECTED. CONTRACTOR SHALL COORDINATE EQUIPMENT INSTALLATION W/EQUIPI,ENT 13 12 MANIACTURER'S INSTALLATION PERscaa . PRE -WIRED BRANCH CIRCUITS DISCONNECTED FOR SHIPMENT TO BE RE- ' 13 CCitECTED BY MANUFACTURER'S INSTALLATION PERSONNEL ON SITE. ELECTRICAL CONTRACTOR TO PROVIDE CORD WIfH PLUG AND FIRE TO + — 14 BROILER. (SJO CORD 1/4 210-NEMA TYPE PLUG "L18-30P). CONTRACTOR SHALL COORDINATE CONDUIT RUN BETWEEN FREEZER, COOLER. I r; 15 EVAPORATORS, AND ROOF TOP REFRIGERATION UNIT WITH MANUFACTURER'S FURNISHED 'WIRING HARNESS. 18 EL ECTRICAL CONTRACTOR TO PROVIDE JUNx;TION BOXES WITH STUB -UPS TO CEILING FOR ANSUL PULL. SYSTEM. (SEE SHT. EQ-2) 17 REFER TO SHEET A/C-1 FOR LOCATION OF A/C UNITS W/ SMOKE DETECTORS. a ROOF POWER FLAN SCALE: 1/8"-1'-0" - r AX now, • r tom., P r , a. '. i _.::_. _'-. _..__.-.._.._._._....._.....:...�..:___..._...._....�.....,_.......`.,....,.:..,,.r,..—....a..,.::..e.,�-..,».�:..v..i......:.a�,.e:...:.v:,ea..,ear.+r....,::,.....:.n...--a.,.....�.-,.v:-:a..........,,....-.�..,......�...;,.�....:,..;.,��,v :.a .{. t Q -NOOD MAINS: M.L.0. 225A GE -NLAB PANEL "A " ' -W22B VOL 120/208V, 30, 4W 60 HZ CF1- 8 P WW ZBP C C T J0` VOLTS -AMPS — C C T N0 C L LOAD -. A _ ___QPLOAD �B l2SC AREA LIGHTS w - "10 20 1 920 1800 920 760 920 '1800 920 1000 1700 900 1050 900 1000 72Q 1750 1000 1750 woo 1800 1200 1750 720 720 920 720 177200 1000 720 800 800 — 800 — 800 — 1000 1000 — _ - 20 1 912 y DINING RM .EIGHTS N Y;:- •, 2 3 20 1 DINING ROOM DECOR LIGHTS 4 ,� AREA LIGHTS 20 5 /20 KITCHEN AREA LIGHTS 6 2 7 20 1 DINING ROOM/KITCHEN DAY & NIGHT LIGHTS 8 `PYLON SIGN •° 20 1 _ 9 20 1 MENU SIGN 10 SECONDARY PYLON SIGN.. & LOGO SIGN, 20 1 11 20 1' TOILET LIGHTS/EF-3 12 DRIVE-THRU .. ORDER STATION/SIGN #12 20 1 20 1 DISPLAY SIGN & D/T GUIDANCE SIGN 14 RED PARAPET LIGHT ,, BAND 20 1 1 20 1 STORAGE ROOM/OFFICE CREW ROOM LIGHTS -16 RED PARAPET LIGHT .. BANG 20 1 17- 20 1 SMOKE DETECTOR ALARM PANEL 18 MANSARD SIGN �_ 20.1 19 1 CEILING FANS 20 RED PARAPET LIGHT r. =BAND 20 1 21 20 1 RELAY PANEL _ 22 4 . r - 20 1 23 20 1 SECURITY LIGHTS 24 EXT:,SOFFIT LIGHTS 'a "12 20 1 25 1 TELEPHONE REC. 26 EXT. SOFFIT LIGHTS "� 1 2 1 - SPARE 28 SPARE' _ 20 y1 29 1 1 30 EF-1 "a -012 31 1 SPACE 32 •s /21 33 1 — 34 • ■ -2 20 35 1 — 36 �� al. 2 37 1 _ 38 SPARE - Y39 1 40 20 1 41 1 — 42 SUBTOTAL 13480 13620 12580 120 _ 120 120 AMPS 112 114 105 TOTAL: 39,680 VA 40 KVA 111 AMPS PANEL -.'A' NOTES. ELECTRICAL CONTRACTOR TO WIRE THESE CIRCUITS THRU MASTER RELAY PANEL. SEE WIRING DIAGRAMS SHT, E-4. V.2. ALL BREAKERS SHALL BE RATED FOR SWITCHING DUTY, 3, ` VERIFY CIRCUIT REQUIREMENTS FOR PYLON SIGN, -NQOD MAINS M. L. 0:'= 225A GE -NLA6 PANEL ' ii i, iEsco W22B - VOLTAGE: .: 12o/208V, 310, 4N 60 HZ � CH-PB /BP C C N0 VOLTs-►s BO pLOAD L W LOAD: �A �B- �CN ROOM R DINING 0 M ECP. 1� ZO 1 1 10 720 1320. 720 1320 720 720 T1800 720 520 720 1500 1925 1500 1925 1610 2060 1610 2060 1610 3150 1000 3150 720 1860yi 2300 1500 2300 1600, 2800 • 1600 2800 1765 1620 210p 1440 2100 1280 860 700 700 1000 y " 12 SERVICE COUNTER, HALLWAY &ROOF'. 2 _ P,O,S.RECEPTACLES q 20 1 3 1 D-T SPEED OF SERVICE COUNTER / CAMERA 4 P,O.S.RECEPTACLES �: 20 1 5 2U 1 OFFICE OUTLETS 6 SPARE _ 20 1 7 20 1 HOT CHOCOLATE - $ / V CLOCK/STOCK STOCK LE EL/BELL "1 2 20 1 9 20 1 IJNDERCOi�JTER REFRIGI 10 TIME 'CLOCK/ DOOR ALARM 20 1 11 20 1 HEAT LAMP 12 COFFEE MACHINE 410 30 13 20 1 HEAT BLANKET & FILTER MAGIC 14 N N _ 2 15 20 1 FRYER CONTROL 16 ICE MACHINE "10 30 17 20 1 FRYER CONTROL 18 N <" 2 9 20 .i GRILL COrJTRQL " .. 20 COFFEE MACHINE "g 40 21 20 1 -' SPARE 22 N _ 2 23 20 1 "12 FRY COMPUTER 24 ICE DISPENSERS & DRINK DISPENSERS "12 yi 25 "10 HAND DRYER 26 BUN GRILL yi 27 30 1 HAND DRYER 28 MICROWAVE OVEN 20 29 40 "8 BISCUIT OVEN (OPT.) 30 U 11 2 3.) 2 —•- N N Y It 3211 HOLDING CABINET & HEAT LAMP 20 1 33 20/1112 1 MULTI PRODUCT HOLDING/ WARMING CABINET 34 TOASTER 010 30 35 yi MULTI PRODUCT HOLDING I CABINETS (2) 36 N 37 �/l2 THAW UNIT 38 VEGETABLE CUTTER 4'i2 F1 39 20 1 REACH -IN FREEZER 40 REACH -IN UNDER COUNTER FREEZER 20 1 41 20 1 _ SPARE 42 SUB -TOTAL 22995 19710 21440 — 120 120 1 120 AMPS 192 164 179 TOTAL: .64,145 VA 64 KVA PANEL 'B' NOTES: 178 AMPS fl'PROVIDE ISOLATED GROUND BUS "CONTRACTOR SHALL WIRE THESE CIRCUITS THRU MASTER RELAY PANEL . 3) ® PROVIDE HLO-1 HANDLE LOCK -OFF .f -.f�k.rti'S'i} .ry"/3 l",�. �Gs�S i� IV: 4\:3/ PlJ�F.,,. {'Si.. i{F ✓/'V. Y,lt J �'lyeS t r}'ti4 SIl�} . y. y a- j ILjit i :?7.,1rE '�fS''Z O 1'•.i r 53. {T i ::'% _.> 5 ( y ., :...r 7 r. .. .•y. -- . ,.t .;N✓. ,. d. .« .) -. a . .: z .r. fi 3 r•. x Y _ .;t' � ., .. .. _ J,.. _ y; .. _.. .n.. esc. d ... •n - - nh ,$ t. ft C . 0 A Pi FICM OR . M , . B 60 A.(SEE !L . GEN . �i ii i NOTE A x sco-w A OR ro E 1 E G 1M PAWL - - - GE-CC6 VOLTS 120/208 3(D 4W 60 HZ. CH-MP4o CCT- DESCRIPTION. VOLTS PHASE POLE FRAME TRIP KVA .AMPS No. 1 A/C UNIT.#1 (PACKAGE UNIT ON ROOF) 208 3 3 100 50 r 11,5 32 2 A/C UNIT #2 (PACKAGE UNIT ON ROOF) 208 3 3 100 50 ` 11.5 32 3 A/C UNIT 03 (PACKAGE UNIT ON ROOF) 208 3 3 100 60' 13.7 38 4 A/C UNIT,44 (PACKAGE UNIT ON ROOF) 208 3 3 100 60° 13.7 38 5 PANEL A 120/208 3 3 225 150 40 111 6 PANEL B 120/208 3 3 225 200 64 178 7 PANEL C 120/208 3 3 225 160 46 126 8 PANEL D 120/208 3 3 125 100 32 87 9 SPACE 120/208 3 3 100 - - - 10 SPACE 120/208 3 3 100 - - - ° ADJUST AS REO'D, IF ELEC. TOTAL 642 AMPS HEATING UNITS ARE USED. LESS DEMAND COOKING LOAD - 50.5 AMPS SERVICE 4-11350 kcmil (CU) IN EACH OF 2- 3" CONDUITS 591.5 AMPS A. MAIN BREAKER SHUNT TRIP PROV DEO ONtYWFEAE REQUIRED 8Y16CAL ECOD. ►� n „ "c • B. ALL PANEL BUSSES AND (UNECTICNS TO BE COPPER. ►°- ' z. 4kN; r P C. A CIRCU BREAKERS I BREAK N S �! ' A C 0 V'' ALL I PANELS B & D T HARATING. B. , UI.. FOR .' a� �. 22000 A.I A.I.C. (MIN.). If IS ELECT.CONTRACTORSRESPONSIBILITY 'TO .CONTACT THE ELECTRICAL` ^ c� • w ., .� a UTILI"fY W.AND OBTAIN WRITTEN COhFIRMATIOtJ OF T},E AVAILABLE- FAULT CUCURRENTo THE SIT ES.CIRCUIT A.I HATING 0' BREAKER. .C.. SW1Ll. BE INCREASED . OR LOWERED FROM THE 22000 A.I.C. BASED ON THE TOTAL FAULT Wf&ff AT : CF ;, x �� w - TFiE LINE SIDE T7-F IMIN CIRCUIT BREAKER. PRESENT IPF�IATION TO BURGER ,. ac-z w KING FOR APPROVAL OF REVISED RATINGS AND INDICATE CtiAP)GE ON st:gUC;; AS -BUILT DRAWINGS. ALL CIRCUIT BREAKERS MUST BE RATED AT OR ABOVE RATED FAULT CURRENT. N� D. PROVIDE GROIND BUS IN ALL PANELS. E. CONTRACTOR SHALL RUN A '10 UIEEN G9UD CONDUCTOR FROM PANEL 'A' GFiO u BUS TO mom LUG AT 'VASTER RELAY PANEL'. � w ►- ' �°�. i � DEMAND - ELEC rR I CAL COOKING LOADS (GAS COOKING LINE-UP AND OTHER ELECTRICAL KITCHEN COOKING EQUIPMENT) CIRCUITS PANEL "B" VA B-8 HOT. CHOCOLATE 1800 m a B-13,15 COFFEE MACHINE ' 3850 B-21,23 COFFEE MACHINE 6300 r B-27 BUN GRILLE 1500 B-29,31 MICROWAVE OVEN 3200 B-30,32 HALF-SIZE OVEN 5600 3r 'TOASTER B-35,37 4200 PANEL "D D-1,3 BROILER 3640 r D-2,4 TOASTER 4220 0-5,7 MICROWAVE OVEN 3200 MASTER RELAY PANEL D-6,8 MICROWAVE OVEN 3200 BROILER HQOD ANSUL INTERLOCK D-9,11 MICROWAVE OVEN 3200 SYSTEM IN MASTER RELAY PANEL D-12,14 MICROWAVE OVEN 3200 ;.`. D-16,18 STEAMER 4950 FRYER HOOD ANSUL INTERLOCK ® TOTAL- 52060 SYSTEM IN MASTER RELAY PANEL ; 1:r (52.1 KVA = 208V X 4-3- 144.E AMPS 24V AC POWER FROM DEMAND LOAD = 65% X 52.1 KVA 33.9 KVA = 94.1 AMPS MASTER RELAY PANEL (PER N.E.C. ART, 220.20) •--- J-BOX ABOVE CEILING TOTAL - 144.6 AMPS. 765% = 94.1 AMPS REDUCTION 50.5 AMPSWillow t ANSUL SNAP ACTION SWITCH P/N 155549 (3) REO'D. DRY CONTACTS (TYP . ) ---- --- I i ---- -----' CIRCUIT.A-26 � ,3 BROWN I I BROWN I. LL \, I 9011AFF " L NOR. I I NOR. I P.O.S. 3/4 E.C. Y:F CLOSED CLOSED I MODEM • ` 42"AFF 12"X12"X4" RECESSED MT'D, I ! I I MGR. o a TEL. CAB. LOCATE AS DIRECTED ,> NOR, RED RED I I NOR' I AREA BY B,K. FIELD REP, I nnc�i I I npc7m I A O Y COORD . W/ TEL . COMPANY YlESi 18 "AFF QD -NOOD MAINS M. L. 0. = 225 A GE -NLAB PANEL "C 11 WESCO -W228 VOLTAGE 120/208V, 3(P, 4W 60 HZ CH=PB LOAD W y C C T N 0 VOLTS -AMPS CCT NO C B W LOAD g 8 r6 C RECEPTACLES #12 201 1 1400 600 •1440 19000 (9040 ' 150012 1440 1500 1440 720 1000 1500 1000 1500 _ 1000 1975 2000 1975 2000 1070 3848 1400 3848 825 720 540 720 72032 -- — — — 30 "10 SHAKE MACHINE 2 AIR COMPRESSOR "12 20 1 tl Y 4 SODA',FACTORY "10 30 5 3144 _ N 6 "10 2 7 30 "10 SHAKE MACHINE 8 VESTIBULE DUCT HEATER rrr " 20 9 10 " N 2 11 3 12 SPARE 20 1 13 20 1 - SPARE 14 RESTROOM DUCT HEATER` 20 15 20 1 _ N 16 Y Y d 2 17 1 18 W.I.B. REMOTE FREEZER REFRIG. SYSTEM "10 30 19 30 "10 GARBAGE DISPOSER (OPT.) 20 Y 21 2 22 tl M 3 23 50 SPARE 24 W.I.B. REMOTE COOLER REFRIG. SYSTEM "12 20 25 2 _ N 26 2 27 20 1 - SPARE 28 COOLER/FREEZER LIGHTS DOOR HEATER, HEAT TAPE 20 1 29 20 1 _ 30 SPARE - 1 31 1 - SPACE SPACE 1 33 - 1 35 1 36 /37 1 3$ - 1 39 T 1 _ 40 _ 41 1 _ - 42 SUB -TOTAL` 17163 13000 14958 120 120 120 AMPS 143 109 125 45,121 VA 46 KVA 126 AMPS PANEL 'C' NOTES ZONES A & B ONLY - SEE,SHEET A/C-1. - - - - - - - - - - - - - - - - - - - - - 2 W A.F.F. I I 0 00 PANEL "D " NOTEFURNISHED BY EQUIP,MFG, IN EQUIP.. MAINS: M. L. 0. = 125A VOLTAGE 120/208V, 3V, 4W 60 HZ I LOAD W C B P CCT N O VOLTS -AMPS CCT NO C B L W LOAD A B C L BROILER °" ' "10 30 1 1820 2110 1820 2110 1600 1600 �0 1600 1600 552 1600 720 2475 1310 2475 1310 1280 30 "10 TOASTER I 2 Y tt 4 . I # 10 2 2 _ N Y 4 MICROWAVE OVEN "12 20 5 30 "10 MICROWAVE OVEN N Y 2 7 /2, N l 8 I, MICROWAVE OVEN 20 9 201 TOPPING WARMER " " 2 11 20 MICROWAVE OVEN 12 I PREP; BOARD REFRIG. 20 1 13 2 N " 14 SPARE 201 75— 30 910 STEAMER 16 UPPER SANDWICH HOLD STATION AND HEAT LAMP 20 1 17 2 "10 1. " 8 LOWER SANDWICH HOLD STATION AND HEAT LAMP 1 20 1 19 20 11 "12 MEAT FREEZER/REFRIG, DISPENSING UNIT 20 SUB -TOTAL I AMPS 11872 120 9225 120 10185 120 TOTAL 31,282 VA 32 KVA 99 77 8r --I A-35,37 F F 350 350 3 360 I WP WP WP WP WP WP I 3-"8 & 1-10 GND, 3-46 & 1-#10 GND. IN 1" C. IN 1" COND. ROOF-"12 & 1-"12 GND. LINE IN1 /2" C. - - - hl-1 !d-2 M-3 M-4 - - — - - - - I 87 AMPS I r - - - - -� GND. IN1 "8 TIME CLOCK FOR NOTES I I I 1 1/2" C. --{ SPRINKLER SYSTEM SEE WIRING ( MASTER I (OPTIONAL) _ 1) EQUIPMENT OUTLETS & CONNECTIONS INDICATED FOR PANEL D DIAGRAM ON RELAY SEE RISER 4"1/0 & 1"6 ` ARE INSTALLED AND WIRED IN MAIN PREP BOARD BY EQUIPMENT I SHT, E-4 PANEL I NOTE "6 GND. IN 2" C, ;. ✓ ` MANUFACTURER. ELECTRICAL CONTRACTOR SHALL PROVIDE AND I I I GENERAL ELECTRIC CONNECT FEEDER `A'IRE & CONDUIT TO PANEL "D " BROUGHT DOWN a T �1 3-POLE, 4-WIRE THYRITE ARRESTOR I THRU EQUIPMENT SERVICE CHASE. I I C � � \ "'J Ll 1 1/24C 9L15BCCO03 2) THIS SCHEDULE SHOWN FOR REFERENCE ONLY. I I I _OR 3) PREP, BOARD EQUIP, MFR. SHALL PROVIDE GROUND BUS IN PANEL AND EQUIP, GROUND CONDUCTOR I I CONTROL I I I PANEL PANEL PANEL N CT YtESTINGHOUSE PANEL IPANELI NAN ,BN NC1. PANEL CAN VALVE TYPEARRESTORI FROM PANEL TO RECEPTACLE DEVICES. (TO BE RUN WITH BRANCH CCT. TO DEVICE) I I I I D I !d 7 YMN yyp g 634.A 217,A01 ` (INDOOR W/ W.P. 4) "CONTRACTOR SHALL WIRE THESE CIRCUITS THRU MASTER RELAY PANEL I ( I ` - - -` T BOX &COVER) h= SEE SCHEMATIC DRAWINGS THIS SHEET AND SHEET E-4. I STRAPOR L - - - - --- _---------- _---- - - - - -- ----� - ----� GROUND BUS SQUARED doom Fi M-5 I )d-6 L - - J-9200-9A , LOCATED IN KITCHEN EQUIPMENT 4-91 /0 & 1-'16 Lj 4tt3/0&1 "6 GND . C MGRS. OFFICE MOUNTED PANEL- GND. IN 211C• IN 2 1/2" C. i r RISER NOTES: SEE SHT . E-2. CONTRACTOR CONNECT LOCATE PER POWER CO. REQUIREMENTS 4 11 ALL FUSED DISCONNECT .SWITCHES FEEDER. ABOVE GROUND 3/4 "C PROVIDE, MATH BREAKER SHUNT TRIP TO BE PROVIDED BY CONTRACTGfi. x2/O FOR GROUND . BREAK GLASS SWITCH (ASCO OR EQUAL) 2 , SEE PANEL. NOTES. „ SEE N. E . C. 250 -81(C ) WHEN REQUIRED BY LOCAL CODE-. MOUNT;. 3, SEE GENERAL NOTES. BOND TO KEBABS. W,P,'SWITCH FLUSH IN OUTSIDE WALL 4. 'T.C,' INDICATES TIME CLOCK'(CR TIME SWITCH) 5, SEE MASTER CONTRCL SYSTEM WIRING DIAGRAM AT METER LOCATION..,; FOR ADDITIONAL CIRCUITS FROM PANEL 'A' THAT ARE CONTROLLED THRU THE M.R.P. " 2/0 2/0 06 COPPER SOLID (GROUND) F. 25 BARE CU ' 6, PROVIDE AN ISOLATED GROUND BUS IN P4EL & GROUND (SEE ' 4"350 kern i l IN EACH OF 2 � RUN CIRCUIT GROUND WIRE TO THIS BLS. RUPi A FIN. _ °6 GREFN GROUND FROM TNLS BUS TO MAIN SERVICERISER NOTE "7) FLR.'a4 rxm&n'antKrr i , 3,. H r r , .. _' .. ... _. :. :., .. _ .,. � .,- . . .. .. '. .- � ,.. _ ..: �� •: pit, — , r > T77- L 'T L_ RV I TL R �A . I C PTrV-1 IP f�n 1 ( rn 1Film 1 N r it Ful , T ERVING I ARE A < I ► ' CUSTOMER BB. J - r�Tw in' 7 J n LEGEND SINGLE:125V-20A TWIST -LOCK RECEPTACLE (NEMA L5-20R) " 0 W/ -ISOLATED GROUND (HUBBELL ,SIG-2310-A OR EQUAL) P.O.S. PRINTER DEVICE DUPLEX 125V-15A TWIST -LOCK RECEPTACLE.(NEMA L5-15R) W/ ISOLATED GROUND (HUBBELL #IG-4700.OR.EQUAL) �❑ P.O.S. CASH REGISTER DEVICE SINGLE 125V-20A=2-POLE-3,WIRE STRAIGHT BLADE r RECEPTACLE OUTLET - 'BALL MTD. (90" A.F.F., - U.O.N,) C,R:T. DISPLAY DEVICE (CETLING MTD.)Y. W/ ISOLATED GROUND ' DUPLEX 125V-20A-2 POLE-3 WIRE, STRAIGHT BLADE RECEPTACLE OUTLET- WALL MTD. (18" A.F,F.,"- U.O.N.) BUMP -BAR ; W/ ISOLATED GROUND. " DUPLEX 125V-20A-2 POLE- 3 WIRE, STRAIGHT BLADE ' TELEPHONE OUTLET FOR P.O.S.MODEM RECEPTACLE OUTLET - CEILING MTD. (9 -6" A.F,F., - U.O.N; ) (ALL OUTLETS HOt'dERUN IN 3/4° CONDUIT W/ ISOLATED GROUND TO TELEPHONE BACKBOARD) MOUNT 90" A,,F,F.' SINGLE 125V-20A`POLE-3 WIRE STRAIGHT BLADE T RECEPTACLE OUTLET - CLG . MTQ .. (9 ' -6 " A;, F . F ., = M.N..) , / A ,'O . S , CABLE W/ ISOLATED GROUND c (BY P.O,S.,SYSTEM SUPPLIER) DOUBLE .GANG JUNCTION BOX. W/ BLANK COVER PLATECQ & 2:1/2" t, EMPTY,, CONDUIT TO 4" ABOVE CEILING U.O.N: .UNLESS OTHERWISE NOTED FOR COMMUNICATION CABLE; r �.f^3,.'�� S Y rm IN p -A {t Ir ;� t3 } s.tr -1 i� >q 'IN E'. }