Loading...
1311, 1321 and 1331 Pine Oak Trl 07-647 SprinklerBUILDING PERMIT07-647 CITY OF SANFORD PF1011T APPt.ICAT10N t erntit Date: .lob Address: -MAGNOLIA PARK CONDOS, 1311,1321,1331 PINE OAK TRAIL LOTS (1, 2&3) Description of Work: _LNSTALL FIRF SPRI_NKI FR MONITORING STEM WITH REMQTE-5jAT_L0N MONITORING Historic District: �.� Zoning: Value of Work: 5—m- Permit Type: Building Electrical _ T Mechanical _ Plumbing Electrical: New Service — It of Ailv1PS iNlechanical: Residential Non -Residential Plumbing/ New Commercial tl of Fi,xnrres Plumbing/New Residential: # of Water Closets Occupancy Type: Residential Commercial Pool Addition/Alteration Chanbc of Scrvtcr ___� ' crnl� r"ary Pole Replacement New (Duct Layout & Energy Cale. Required) tt of' Water & Sewer Lines It of Gas Lines Plumbing Repair — Residential or Commercial ' Industrial _ Total Square Foota,,e: Construction 'Type: TM # of Stories: It of Dwelling Units: Flood Zone: (F@MA forat required for other than X) Parcel N: . (Attach Proof of Ownership & Legal Description) Osvncrs Name & Address: —DR- HO-RTON; 1NC- 5850 TG LH— TVD; STE-600, ORI ANDO-,---FL-3-28 2 --_ _ Phone: M7J-85.0-51Q0 Contractor Name&Address:.-__WA-TN.E-AUTOMATTC FIRE SPRINKLERINC....... ______- ---- 2.2.2_CAP .ITOL CT.__000EE, FL 34761 �--_ State Licensc Number.: EF20000358 _- Phone & Fax: -(407--�-M7- 5588; 407-656-802iontact Person:. JAMES BALIUS/ BECKY Phone.- 407-877-5588 13011ding Company: Address: Mortga�c Lcndcr: Address: ArchitccdF,ngirrccr: Address: Phone: Fax Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work wilt be perforated to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELF.CTRICAI-, WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, and AIR CONDITIONERS, etc. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING 1*0 OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that l will notify the owner of the property of the requimntcty f Florida Lien Law, FS 713./ 1-1-91-2-007 Signature of Owner/Agent Date Signature of " nlracwr/Agent Date Print Owner/Agent's Name Print Cc ntrac((A/Agent's Nam,- _ ' ' 41j8�2007 Signature of Notary -State of Florida Date na ure of NOnlr -State of Florida Date b Y g Y Owner/Agent is _..._.__ Personally Kno%�n to Nle or Produced ID APPLICA PION APPROVED BY! 13ldg: Zoning: (In,.ial fate) Special Conditions: C.'onnactor/Agent is X_ Personally Kno��n w N1c or".,, Produced ID ....... --- (Initial & Date) Luktics: (Inir'ai & Datc) FD:M4 -- (IrHli: GENERAL NOTES 1.) Electrical Contractor to supply AC power to fire alarm panel, on dedicated 20 amp breaker, with breaker lock. All conduit, boxes, & stub ups by electrical contractor. 2.) Raceways installed and permitted by others. 3.) Customer to provide 2 phone lines at panel location. Each with different long distance carrier. 4.) Monitoring by Marlin Central Monitoring 3600 Commerce Blvd. Ste 201 Kissimmee, Florida 34741 Ph. 407-582-9300, fax 407-582-9301 UL 293958-001 EF A00800 1" Conduit & SLC Pipe buried minimum 24' FIRE ALARM SITE PLAN_ SCALE , =.,n_o" FIRE ALARM SYMBOL LEGEND (NOTE: ALL SYMBOLS MAY NOT BE USED IN DRAWING) SYMBOL DESCRIPTION MOUNTING HEIGHT TYPE JUNCTION BOX R MANUAL PULL STATION 4' -O' AFF TO TOP 4' SQ. w/S. G. M, R, OA SMOKE DETECTOR w/AUX-RELAY CEILING 4' OCT. OSMOKE DETECTOR CEILING 4' OCT. DUCT SMOKE DETECTOR IN DUCT 4' SO. 24Vdc SOLENOID VALVE @DEVICE 4'SQ. LOW AIR PRESSURE SWITCH @DEVICE 4' SO. Qy SPRINKLER TAMPER SWITCH @DEVICE 4' SO, ►y FLOW SWITCH @DEVICE 4' SO. ® HEAT DETECTOR 13S` OR 194 CEILING 4' OCT. ❑M 1 MINI HORN 84" CEN. AFF. 4' SO. ❑1 SPEAKER SEE SPEC. PER MFG. \O STROBE LIGHT 84' CEN. AFF. 4' SQ, SPEAKER/STROBE LIGHT 84" CEN. AFF. 4'SO, I�f CM = CEILING MOUNT �O'R ELEVATOR WARNING LIGHT 4' SQ. w/S. G. M. R. C� BELL 84' CEN. AFF. 4' SQ. D DOOR HOLDER (FLUSH) 6' BELOW TOP OF DOOR 4'SO, w/S. G. M. R. DOOR HOLDER (SURFACE) SEE SPEC. PER MFG. - END OF LINE RESISTER @DEVICE N.A. RELAY(CONTROL) @DEVICE 4 11/16 SO. w/COVER FCP Fire Alarm 6' -0' AFF TO TOP ENCLOSURE Control Panel FAC Fire Alarm 6' -O' AFF TO TOP ENCLOSURE Communicator FSA Fire System 5' -O' AFF TO TOP PER MFG. Annunciator O U 6'xI20 VOLT DC BELL V/ �v 0- VEATIERPIZLDF BACKING __ - _ _ " _ BOX.(VIRED BY OTHERS) TIE IN OF SPRINKLER SYSTEM TO ALARM SYSTEM BY OTHERS HYDRAULIC DATA PLATE MOUNT AT RISER ,9 (1) 6 HEAD SPARE HEAD BOX V/ 3 OF EACH TYPE OF SPRINKLER V/ APPROPRIATE HEAD WRENCHES PER NFPA 13R 14' RESIDENTIAL SINGLE FDC V/ It' PLUG AND CHAIN V/ LETTERED SIGN -I$' SWING CHECK VALVE 3' PVC SLEEVE--' PIPE ROTATED FOR CLARITY 1' CONDUIT 1' CONDUIT 2'x2'x$' CPVC TAPPED TEE V/ $'Xr GALV. BUSHING AND 300 PSI WATER GAUGE POT IN FL 2'xCPVC RETEE - V/ POTTER GLUE 1N FLOW SNITCH r2' RUBBER FACED CHECK VALVE ADP _ �- l' BALL VALVE —I' x 0-2 GALVANIZED NIPPLE �— I' CPVC FEMALE ADAPTER 2' MILVAUKEE GRVD, BUTTERBALL VALVE BSR V/ TAMPER SWITCH 17- UG1 TYPICAL RISER DETAIL IN scaly \_OUT WALL V/ I' CPVC 45' V/ Ixk ADPT V/ SAWN SPRINKLER WITH THE SMALLEST (ISOFICE IN THE SYSTEM 6' X 6' X 4' Weottlerproof Junction Box mounted at supply side of back flow preventor (See Backbox Detail Above) 2' AIES MODEL 2000E DOUBLE CHECK BACKFLOV ASSEMBLY V/ (2) 2' MILVAIEKEE BUTTERBALL VALVES V/ TAMPER SWITCHES. A 7 PSI FIXED PRESSURE LOSS 1S INCLUDED AT BACKFLOV FOR ALL CALLS GROOVED COUPLING r r 0 O r 6" X 6" X 4" Weatherproof WLv r 'y �;, 2Ax2 Galy. Tee w/ txk Junction Box mounted of supply Gals Bushhg. In5tau f 0-4 Galy side of back flow preventor Fipple w/ 3 way valve, rouge & Plug (See Backbox Detail @ Left) 1' CONDUIT r 2' cPvc , / cPvc `2' GALV 90' 2' GALV 90' f BACKFLOW PREVENTION DETAIL MD sure ed at OFFICE REVIEWED anford Fire Prev pO S r Date oop To Next Device 1" Conduit & SLC Lo From Previous Device. with .M tape 6' above pipe. USE 1!' UNISTRUT OR EQUAL TO SUPPORT BOX TYPICAL AT ALL BACKFLOWS AND SPRINKLER RISERS PER NFPA 72, 2002 EDITION SECTION 10.2.2.1 — THE OWNER OR THE OWNER'S REPRESENTATIVE SHALL BE RESPONSIBLE FOR INSPECTION, TESTING, AND MAINTENANCE OF THE SYSTEM AND AND ALTERATIONS OR ADDITIONS TO THIS SYSTEM PERMIT #...� FIRE ALARM SYSTEM DIVISION License Number EF20000358 O O NICET-95925 U 0 0\ D NFL Fire Protection Engineer222 CAPITOL COURT OCO PH: (407) 877-5589 FAX: (407) 656-8026 Certificate of Authorization Number 7523 ALL DOCUMENTS, INCLUDING ORIGINAL DRAWINGS, SPECIFICATIONS, FIELD NOTES, ESTIMATES AND DATA, INCLUDING COMPUTER PROGRAMS PURSUANT TO THIS PROJECT ARE AND WILL REMAIN THE PROPERTY OF WAYNE AUTOMATIC FIRE SPRINKLERS,INC. (WAFS) AS INSTRUMENTS OF SERVICE. THEY ARE NOT INTENDED, NOR REPRESENTED TO BE SUITABLE FOR RE -USE BY THE CLIENT, OR OTHERS, ON EXTENSION OF THIS PROJECT, OR FOR ANY OTHER PROJECT. ANY REUSE, OR ADAPTATION OF THE INFO- RMATION CONTAINED HEREIN, WITHOUT SPECIFIC WRITTEN PERMISSION FROM WAFS MALL BE AT THE CLIENTS SOLE RISK, WITHOUT LIABILITY, OR LEGAL EXPOSURE TO WAFS, AND WILL ENTITLE WAFS TO FURTHER COMPENSATION AT RATES TO BE AGREED ON BETWEEN WAFS AND THE CLIENT. THE CLIENT SHALL ALSO INDEMNIFY AND HOLD WAFS HARMLESS FROM ANY AND ALL CLAIMS. DAMAGES, LOSSES AND EXPENSES,INCL- UDING ATTORNEYS FEES RESULTING FROM ANY SUCH PERMISSIONS. IMPORTANT OWNER INFORMATION THIS DRAWING IS BASED ON THE OWNERS ACCEPTANCE OF THE LATEST EDITION OF NFPA /25 AS THE APPLICABLE STANDARD FOR THE INSPECTION,TESTING,AND MAINTENANCE OF WATER BASED FIRE PROTECTION SYSTEMS, IF THE BUILDING OWNER HAS NOT RECEIVED A COPY OF THIS PAMPHLET AND OR IS NOT FAMILIAR WITH THE OPERATION AND MAINTENANCE OF THIS SYSTEM PLE SE CONTACT THE NEAREST OFFICE OF WAYNE AUTOMATIC FIRE SPRINKLERS,INC. NO. DATE REVISIONS BY 1 � I 3 4 SYSTEM INFORMATION MANUFACTURE SILENT KNIGHT BATTERY AH MODEL 5820 7 # OF ALARM ZONES # OF SIGNAL CIRCUITS DATE OF TEST TIME OF TEST TEST TAKEN BY PANEL & BREAKER SYSTEM NOTES SYSTEM DESIGN & INSTALLATION ACCORDING TO NFPA 72 2002 EDITION, NEC 2002 EDITION, NFPA 101 2003 EDITION, AND ALL STATE AND LOCAL CODES. INSTALL FIRE SPRINKLER MONITORING SYSTEM WITH REMOTE STATION MONITORING. INDICATING APPLINCES 11 SYMBOL TYPE I QTY I COMMENTS INITIATING DEVICES I� �I TOTAL THIS SHEET \"N/W AY N FE Automatic Fire Sprinklers, �Ic ORLANDO — JACKSONVILLE — FORT MYERS POMPANO — CHARLOTTE, NC CORPORATE OFFICE — ORLANDO, FLORIDA 222 CAPITOL COURT OCOEE, FL 34761 PHONE: (407) 656-3030 FAX: (407) 656-8026 PRO,ECT: MAGNOLIA MELLONVILLE AVENUE SANFORD, FLORIDA CONTRACT WITH: D.R. HORTON ORLANDO 5850 T. G. LEE BOULEVARD SUITE 600 ORLANDO, FL 32822 sYSTEM # SITE PLAN DRAWN BY- JAMES BALIUS CHECKED BY: DESIGNED BY: JAMES BALIUS DATE: 11-14-05 SCALE: 1" = 30' — 0" AHJ: CITY OF SANFORD CONTRACT # W C 0 5114 31 SHEET # A 1 OF o o�