107 Pine Isle Dr - BR18-002897 - SOLARt z , R`ulding & Fire Prevention DivisionJUN282018PERMITAPPLICATION Application No: l Documented Construction Value: $ Job Address: 107 PINE ISLE DR, SANFORD Historic District: Yes No Parcel ID: 10-20-30-511-0000-0980 Residential Commercial Type of Work: New—] Addition Alteration Repair Demo Change of Use Move Description of Work INSTALL ROOF MOUNTED SOLAR PV SYSTEM. 7.2KW Plan Review Contact Person: &-}-- OJ-,,Z C (Uri ref Title: Phone: c;i'g3 93&( Fax: Email: tA pro eC-1- n\y c nS tiG Property Owner Information Name ARTHUR, JOSEPH Phone: 832.549.8989 Street: 107 PINE ISLE DR Resident of property? : YES City, State Zip: SANFORD, FL 32773 Contractor Information Name OTTO CURBELO- BLUE SKY SOLAR ENERGY Phone: 727.648.4913 Street: 13747 65TH ST Fax: N/A City, State Zip: LARGO, FL 33771 State License No.: EC13004873 Architect/Engineer Information Name: Phone: Street: Fax: City, St, Zip: E-mail: Bonding Company: Mortgage Lender: Address: Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating constructioninthisjurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools furnaces, boilers, heaters, tanks, and air conditioners, etc. FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: 611 Edition (2017) Florida Building Code Revised: January 1, 2018 Permit Application NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the,public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal. The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in. accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value, credit will be applied to your permit fees when the permit is issued. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. G - Signature of 5 rida Date EPHANIETEPHENS2F218087MY'ko2019"" corr Owner/Agent is Personally Known to Me or Produced ID d Type of ID DL uo C"6tt-- (-a-4 ig Signature of Contractor/Agent Date Print Contractor/Agent's Name Si MPersona Date NIE— S ZynaISSIONSApril otaySerContractor/APersn to Me or Produced ID, d Type of ID DL BELOW IS FOR OFFICE USE ONLY Permits Required: Building Electrical[] Mechanical Plumbing Gas Roof Construction Type: Total Sq Ft of Bldg: Occupancy Use: Min. Occupancy Load: New Construction: Electric - # of Amps Fire Sprinkler Permit: Yes No # of Heads APPROVALS: ZONING: ENGINEERING: COMMENTS: UTILITIES: FIRE: Flood Zone: of Stories: Plumbing - # of Fixtures Fire Alarm Permit: Yes No WASTE WATER: BUILDING: -5C' 1.17 • t g Revised: January 1, 2018 Permit Application Altamonte Springs, Casselberry, Lake Mary, Longwood, Sanford, Seminole County, Winter Springs Date: G • S I hereby name and appoint: Zxba • ckh --•1-h.T an agent of Name of to be my lawful attorney -in -fact to act for me to apply for, receipt for, sign for and do all things necessary to this appointment for (check only one option): The specific permit and application for work located at: icy P V-e- kSV& (QC - Street Address) Expiration Date for This Limited Power of Attorney: G • '2 —+ .19 License Holder Name: (AA: 0-11 ( (QQI b State License Number: E C 13 00 W q Signature of License Holder: Q—'VQV' STATE OF FLORIDA COUNTY OF •-L- The foregoing instrument was acknowledged before me this day of, _urg_ 200 1 , by h 6 ) (- tp who is pe sonY ally known to me or who has produced (QL-- as identification and who did (did not) take an oath Situr > Notary Seal) - Mio Print or type name Notary Public - State of FL - Commission No. F 69 1906 My Commission Expires:--4-19 Rev. 08.12) PHOTOVOLTAIC MODULE GENERAL NOTES: ' RrcoRco,,.. 1. APPLICABLE CODE: 2017 RORIDA BUILDING CODE 6th ED. & ASCE 7-10 MINIMUM DESIGN LOADS FOR BUILDING AND OTHER STRUCTURES. 2. BOLT DIAMETER AND EMBEDMENT LENGTHS ARE DESIGNED PER NDS(2012) REQUIREMENTS. ALL BOLT CAPACITIES ARE BASED ON A SOUTHERN YELLOW PINE (SYP) WOOD ROOF TRUSS AS EMBEDMENT MATERIAL. 3. ALL WIND DESIGN CRITERIA AND PARAMETERS ARE FOR HIP AND GABLE RESIENTIAL ROOFS, CONSIQERING FROM A 7° TO A MAXIMUM 27- (2/12 TO A MAXIMUM 6/12 PITCH) ROOF IN SCHEDULE. ALL RESIDENTIAL ROOFS SHALL NOT EXCEED 30'-0" MEAN ROOF HEIGHT. 4. ROOF SEALANTS SHALL CONFORM TO ASTM C920 AND ASTM 6511. 5. THIS SHEET REFLECTS STRUCTURAL CONNECTIONS ONLY. REFER TO MANUFACTURER MANUAL FOR ALL ARCHITECTURAL, MECHANICAL, ELECTRICAL, AND SOLAR SPECS. 6. ALL ALUMINUM COMPONENTS SHALL BE ANODIZED ALUMINUM 6105-T5 UNLESS OTHERWISE NOTED. 7. LAG BOLTS SHALL BE ASTM A276 STAINLESS STEEL UNLESS OTHERWISE NOTED. 8. ALL IRONRIDGE RAILING AND MODULES SHALL BE INSTALLED PER MANUFACTURER INSTRUCTIONS. 9. 1 CERTIFY THAT THE INSTALLATION OF THE MODULES IS IN COMPLIANCE WITH FBC:BUILDING CHAPTER 16 AND FBGRESIDENTIAL CHAPTER 3. BUILDING STRUCTURE WILL SAFELY ACCOMMODATE CALCULATED WIND LATERAL AND UPLIFT FORCES, AND EQUIPMENT DEAD LOADS. ULTIMATE WIND SPEED V" R(MPH) WIND EXPOSURE B MAX SPAN, MAX CANTILEVER WIND EXPOSURE C MAX SPAN, MAX CANTILEVER WIND EXPOSURE D MAX SPAN, MAX CANTILEVER EMBED. DEPTH REQ, 110 6'-0" O.C., V-4" O.C. 6'.0" O.C., V-4" O.C. 4'-0" O.C., V-4" O.C. 3" * 120 6'.0" O.C. , VX O.C. 4'-0" O.C., V-4" O.C. 4'-0" O.C., 1'4" O.C. 3" * 130 4'-0" O.C., V-4" O.C. 4'-0" O.C., V-4" O.C. 4'-0" O.C., V-4" O.C. 3" * 140 4'4' O.C., V-4" O.C. 4'-0" O.C., VX O.C. 4'-0" O.C., V-4" O.C. 3" * 150 4'-0" O.C., VX O.C. 4'-0" O.C., V-4" O.C. 4'-0" O.C. , V-4" O.C. 3" * 160 4'-0" O.C., VX O.C. 4'.0" O.C., V-4" O.C. 4'-0" O.C., 1'4" O.C. 3" * 170 4'-0" O.C., V-4" O.C. 4'-0" O.C., 1'4" O.C. T-0" O.C., 9" O.C. 3" SCHEDULE REFLECTS COMPONENTS AND CLADDING (C&C) NOMINAL WIND PRESSURES WITH EXPOSURE " B" - "C" - "D", RISK CATEGORY II , ENCLOSED BUILDING AND IT < 30'4- PER ASCE 7-10 MINIMUM DESIGN LOADS FOR BUILDING AND OTHER STRUCTURES" AND 2017 F.B.C. 6th ED LAG BOLT DEPTH REQUIRED IN WOOD MEMBER EXCLUDES ANY ROOF DECKING THICKNESS. 3RD RAIL IS REQUIRED PER ROW OR COLUMN FOR SPECIFIED WIND SPEED AND EXPOSURE. INSTALLATION OF MODULES SHALL BE LOCATED IN ROOF WIND ZONE 1 AND 2. WIND ZONE 3 REQUIRES SITE SPECIFIC STRUCTURAL ENGINEERS APPROVAL. ITEM DESCRIPTION UTY, 1 SCREW, kRRA D1 ICAPFLANGE, HEX HEAD5/16'-18 X 1' N - A. GRADE 8, ZINC 2 POST, 1-1/4. OD X 3-1/4', 1 6063-T5/6063-T6, MILL 3 WA R, SEALING, 5/16' ID X 1 1-1/4' ODEPDM BONDED SS 4 FLASHING, REPLACEMENT TILE, 1 625' CONE, ALUMINUM MILL 5 COLLAR, COUNT R FLASHING, 1-1/4' I EPDM 1 6 VA N / ' 1 X1' OD, 18-8 SS 7 18-8 SS 1 8 X 1' UNC-2A I8-8 SS 1 8 to 6 U AFL AVAILABLE IN RACKING COMPONENTS MILL, AND BLACK NOT INCLUDED FINISHES 3 2 1 FLASHFOOT2 & QMOUNT TILE REPALCEMENT DETAIL l, EV1EWEDPOR CODE COMPUANCE /I S. Y.P. 2X4 LOCATE BETWEEN PLANS TRUSSES AND NAIL WITH 2- 16D NAIL PATTERN AT EACH 1 - % b END TO WOOD TRUSS DATE - V'* - 10- 16x2' ST STL SELF TAPPING 12" ALUMINUM INTERNAL SC EW TYP 4 PLCS PER BEAM SPLICE SPLICE BAR (USE WHEN SPLICE AT MID -SPAN W/ o ( 4) #10-16X2" ST STL SELF TAPPING SCREWS TYP IR NRIDGE XR 100 ALUM RAIL TYP. TYPICAL SOLAR RAIL BEAM SPLICE DETAIL 5 SCALE: 1 2"=1'-0" CUT OUT OR REMOVE TILE TO INSTALL "ROOF ATTACHMENT. RE -INSTALL, RE - FILL AND RE -SEAL TILES AFFECTED WITH APPROVED ROOF MATERIALS LE SIDE < 25% OF MODULE LENGT TIGHTEN TO TORQUE PER MANUF. INSTRUCTIONS PHOTOVOLTAIC MODULE TYP. ALUM L-FOOT TYP EACH STANDOFF 8" - 16 HEX CAP ST STL BOLT AND ST STL SERRATED FLANGE NUT TY P. 3 2 2 4' TYP. 3 1 I4' TYP. y GABLE END BUILDING 1 HIP END BUILDING ROOF -- ROOF WIND AREA ZONES WIND AREA ZONES 1 2 3 2 2 _- 223 3 2 O O SANFORD BUILDIN DIV I S. Y.P. 2X4 LOCATE BETWEEN A PERMIT ISSUED SHALL BE CONSTRU TO BE A TRUSSES AND NAIL WITH IGENSE TO PROCEED WITH THE WORK ND NOT AS 2-16D NAIL PATTERN AT EACF AUTHORITY TO VIOLATE, CANCEL, ALT R OR S END TO WOOD TRUSS 3 ' 322SIDE ANY OF THE PROVISIONS OF THE E ICA.L CONCRETE TILE OR CODES, NOR SHALL ISSUANCE OF A PER iT PREVENT COPMPOSITION SHINGLE THE BUILDING OFFICIAL FROM TH FTER REQUIRING A CORRECTION OF ERROR IN PLANS. ROOFFINISHCONSTRUCTIONORVIOLATIONSOFHISCODETYPICAL PHOTOVOLTAIC ARRAY PITCHED ROOF LAYOUT - WI NES - SCHEDULE - PLAN 1 MISSED TRUSS CONNECTION DETAIL SCALE: NONE S-0I SCALE: 1 2"=1'-0" FLAT OR BARREL ROOF TILES TYP. WOOD WOOD ROOF SHEATHING TRUSS TYP, CONIC TILE CONNECTION DETAIL SCALE: 1 2"=1'-0" 8" - 16 HEX CAP ST STL BOLT AND ST STL SERRATED FLANGE -NUT TYP. PHOTOVOLTAIC MODULE TYP. IRONRIDGE MID OR END CLAMP IRONRIDGE XR100 RAIL QMOUNT TILE REPLACEMENT FLASHING QMOUNT TILE REPLACEMENT ATTACHMENT 2) 16' ST STL LAG BOLT - SEE SCH FOR EMBED DEPTH REQ. END - CLAMP OR MID IRONRIDGE XR100 TYP, COMPOSITION SHINGLE/ METAL ROOF ( DET OMITTED FOR CLARITY) 1) 6' ST STL IRONRIDGE LAG BOLT - FLASHFOOT2 TYP, WOOD SEE SCH FOR SHEATHING WOOD ROOF EMBED DEPTH TRUSS TYP. REQUIRED COMPOSITION SHINGLE METAL ROOF FINISH 3 CONNECTION DETAIL SCALE: 12"=l'-0" S-01 Sq IFORD# 1 8 - 2 8 97 COPYRIGHTED BY CASTILLO ENGINEERING SERVICES, LLC Castillo ngineering CASTILLO ENGINEERING SERVICES, LLC COA a 28315 2381 CREST RME COURT SANFORD, F132771 EL" I'll"I IER110MT11E CA8"l10-1 PE11111 REVISIONS DESCRIPTION DATE REV PROJECT NAME Cie cn OO F= O V oc Lu z O fl- O cle Va w LLJ 0 N E2 O w w CieQ Oo z Q SHEET NAME DATA SHEET SHEET SIZE ANSI B 1 1" X 17" SHEET NUMBER S- 01 DIRECTORY OF PAGES PV-1 PROJECT SUMMARY PV-2 SITE PLAN P.V-3 SINGLE -LINE DIAGRAM PVA SAFETY LABELS PV-5.1 ATTACHMENT PLAN 5.1 PV-5.2 ATTACHMENT PLAN 5.2 PV-5.3 ATTACHMENT PLAN 5.3 PV-6 ATTACHMENT DETAILS PV-7 FIRE SAFETY PLAN MODULE DATASHEET OPTIMIZER DATASHEET X INVERTER DATASHEET Z MOUNTING SYSTEM DATASHEET a MOUNTING SYSTEM ENGINEERING LETTER Q UL 1703 CLASS A FIRE CERTIFICATION UL 2703 GROUND AND BONDING CERTIFICATION ANCHOR DATASHEET PROJECT DETAILS PROPERTY OWNER PROPERTY ADDRESS 107 PINE ISLE DR, SANFORD, FL 32773 US APN ZONING RESIDENTIAL USE AND OCCUPANCY CLASSIFICATION ONE- OR TWO-FAMILY DWELLING GROUP (GROUP R3) AHJ UTILITY COMPANY FLORIDA POWER & LIGHT CO ELECTRICAL CODE 2014 NEC (NFPA 70) FIRE CODE 2015 NFPA 1 CONTRACTOR INFORMATION COMPANY BLUE SKYSOLAR LICENSE NUMBER ADDRESS 4628 EAGLE FALLS PL, TAMPA, FL 33619 PHONE NUMBER CONTRACTORSIGNATURE k#4: do* awls f vo- L-] 1 PLOT PV-1 SCALE NTS 8 Pr raF ri5irt t' Cmm. saD ford x Hbatt+ro r UrC ics p I(s;te national r t ,I*q-Luke. Lake Mwv _ i A,eWl rLmkeJesup i0RAr2s g{Ky, fMll r`FE iio+•r Hamm, 4 tw iduC mNw M'231'?.sxi 2 LOCALE PV-1 SCALE: NTS SCOPE OF WORK P-90327 THIS PROJECT INVOLVES THE INSTALLATION OF SOLAR PANELS. THE SOLAR PANELS WILL BE RACKED USING A PREENGINEERED RACKING SYSTEM. THE RACKED MODULES WILL BE ELECTRICALLY CONNECTED WITH DC TO AC POWER INVERTERS AND INTERCONNECTED TO THE LOCAL UTILITY USING MEANS AND METHODS CONSISTENT WITH THE RULES ENFORCED BY THE LOCAL UTILITY AND PERMITTING JURISDICTION. THIS DOCUMENT HAS BEEN PREPARED FOR THE PURPOSE OF DESCRIBING THE DESIGN OF A PROPOSED PV SYSTEM WITH ENOUGH DETAIL TO DEMONSTRATE COMPLIANCE WITH APPLICABLE CODES AND REGULATIONS. THE DOCUMENT SHALL NOT BE RELIED UPON AS A SUBSTITUTE FOR FOLLOWING MANUFACTURER INSTALLATION INSTRUCTIONS. THE SYSTEM SHALL COMPLY WITH ALL MANUFACTURERS LISTING AND INSTALLATION INSTRUCTIONS, AS WELL AS ALL APPLICABLE CODES. NOTHING IN THIS DOCUMENT SHALL BE INTERPRETED IN AWAY THAT OVERRIDES THEM. CONTRACTOR IS RESPONSIBLE FOR VERIFICATION OF ALL CONDITIONS, DIMENSIONS, AND DETAILS IN THIS DOCUMENT. SYSTEM DETAILS DESCRIPTION NEW GRID -INTERACTIVE PHOTOVOLTAIC SYSTEM WITH NO BATTERY STORAGE DC RATING OF SYSTEM 7.20OW AC RATING OF SYSTEM 7,60OW AC OUTPUT CURRENT 32 OA INVERTER(S) 1 1 X SOLAR EDGE SE760CH-US MODULE Q-CELLS Q.PEAK BLK-G4.1 300 ARRAY WIRING 11) STRING OF 10 1) STRING OF 14 INTERCONNECTION DETAILS POINT OF CONNECTION NEW LOAD SIDE AC CONNECTIONPERNECSECTION705.12(D) UTILITY SERVICE 120/240V 1Q ELECTRICAL PANEL MAIN SERVICE PANEL WI200A BUSBAR, 200A MAIN BREAKER SITE DETAILS ASHRAE EXTREME LOW O-C (32`F) ASHRAE 2%HIGH 33-C(91°F) CLIMATE DATA SOURCE VERO BEACH MUNICIPAL AIRPORTKVRB) WIND SPEED RISKCATEGORY II WIND EXPOSURE CATEGORY GROUND SNOW LOAD 2 w n M w CN w ch JOCn JLL w cz Q Z J rZ O O ILL Q U) w F- ct CD PROJECT Pv-1 1 SITE PLAN AERIAL VIEW PV-2 SCALE: 1" = 20' GENERAL NOTES EQUIPMENT LIKELY TO BEWORKEDUPON WHILE ENERGIZEDSHALL BE INSTALLED IN LOCATIONS THAT1SATISFYMINIMUMWORKINGCLEARANCESPERNEC SECTION 110.26. CONTRACTORSHALL USE ONLY COMPONENTS LISTED 2 BY A NATIONALLY RECOGNIZED TESTING LABORATORYFORTHEINTENDEDUSE. CONTRACTOR IS RESPONSIBLE FOR FURNISHING ALL 3 EQUIPMENT, CABLES, ADDITIONAL CONDUITS, RACEWAYS, AND OTHER ACCESSORIES NECESSARY FOR A COMPLETE AND OPERATIONAL PV SYSTEM. WHERE OC PV SOURCE OR DC PV OUTPUT CIRCUITS ARE RUN INSIDE THE BUILDING, THEY SHALL BE CONTAINED IN METAL RACEWAYS, TYPE MC METAL - 4 CLAD CABLE, OR METAL ENCLOSURES FROM THE POINTOFPENETRATIONINTOTHEBUILDINGTOTHEFIRST READILY ACCESSIBLE DISCONNECTING MEANS, PER NEC SECTION 690.31(G). ALL EMT CONDUIT FITTINGS SHALL BE LISTED AS5WEATHERPROOFFITTINGSANDINSTALLEDTOENSUREARAINTIGHTFIT, PER NEC SECTION 358.42. tOARRAY N) PROPOSED ROOF -MOUNTED PHOTOVOLTAIC 8 12 (34-) SLOPED ROOF, 3 PV MODULES BLACK FRAME), 272- AZIMUTH OARRAY N) PROPOSED ROOF -MOUNTED PHOTOVOLTAIC 8.12 (34") SLOPED ROOF,14 PV MODULES BLACK FRAME),180°AZIMUTH O3 WROPOSED ROOF -MOUNTED PHOTOVOLTAIC AY. 8:12 (34-) SLOPED ROOF, 7 PV MODULES BLACK FRAME), 89- AZIMUTH O N) INVERTER (11), OUTDOOR OC14GUIT N TRANSITION BOX (JB1`, OUTDOOR, OUTPUT CONDUCTORS SHALL BE RUN IN EMT CONDUIT OVER ROOF NO CLOSER THAN OS ABOVE ROOFSURFACE O PUT CIRCUITCONDUCTOSITIONBOXRSSHALLBERUNINEMTCONDUIT OVER ROOF NO CLOSER THAN 0.5" ABOVE ROOF SURFACE P- 90327 m Lu cn n M j w M 0 fn u- z O d O 0 Q ocoW0_ SITE PLAN PV- 2 NMOWLE E MODULES Oi MMEANONWEL PNAX PfC ISO OF YOC VYP TEMP. COEFF OFVOC IMRATINGOPTIIMIgR PMI N N OLHLSO.PEAIl BlX64.1000 30IN 277W OnA B.26A YBV B2.4V 4L111V1•C PMI-24 INVERTERS 3DOW © F NAIEANO HNDOEL ACVOLTAGE I GROUND MA%OCPD RATNG MAXOUTWCURpENT MAXPPUTCURRIENr MAXIPWVTATAGE CECWEJ(YREDFFFXxENCV It 1 SOLAR EDGE SE7NMRAGS 124" NIV ummuMOED I IDA I TrMKW V.0A 20M 48W I6I.D% POWER OPTIMIZERS 1 OCPDS O ON, RATED CIRIET7T NAX VOLTARE REF MDOEL RAIID INPUTPONER MA%w, CLRRENT NA%IN"ISO NA%OCVOLTA(E EFFICIENCYREF1X11 1 AOA z4ovAc POt-N I N I SOLAR EDGE pDID I — 1 1. 111.IIA 4BV BB6% YSTEM SUMMARY NOTES MINGIM STRINGt2 THEODUWVOLTMEOFTHEPONERDPT01IxERSAREREGRATMBYTWMaTER. THEYARENOTVAXOUTPUTCURRENTRSA15ARpm® BY THE NUMBER OFMODULES WTHE MING. THE CONTINUOUS CURRENT OFASINGLE STRING IS JUNCTION ROXES SERIESNGVOLTAGE 14400V 104OW EOW M THE MAXIMUM OUTPUT CURRENT OFTHEOPTIMIZER. JBI.2 MG CURRENTw I05A TSA OWER T,DOW TIESOIMEDGE INVERTER IS EOUPPED WITH ARAPID S2NTDOWN FEATTRE MICH CONFORMSTO NECeFEATUREEJLLSTSTODE81ERGxEWSOURCEOWER6.BTFw SECTION 660.12, MICH REQUITES THAT ARAPID SMITODWN CRCUITS FROM AU SOURCES TO LESS MAN W VOLTS WRHM IU SECOM05. INVERTERNTR 74MWTHESPEC6EOOPTIMIxERCANBESUBSTITUTEOWTTHAP{00PWSPSALOR FISTS.R¢SEOFTMIIDiSNAVEC)AD pOVAi 8,49]W AN INPUT VOLTAGE WIDOW WIDE ENOUGH TOACCOAWOATE THE OUTPUTVOUTAGE RANGE OF THE MODULE ISASOVETHE MAX OUTPUTA\A ATTIEDESIGN TEMPERATURES, HAVE AMAX MPA CURRENT RATINGTHAT DIIRENT OFTHE MODULE AND AMAX POWER INPUT THAT IS ABOVE THERATED POWER OUTPUT OFTHE I uODULE. 0 MGRW91DEOGYMMD000NDUCTORSSFV KCCLOR,COOEDASFOLLOWS. OCPOSRNE SHALLBERFDORMNOEDRED) AND DCNEGATIVE SHALL BE BUCK TOR MARKED BLAM MAX DC VOLTAGE OF ARRAY IS M)CEDBY THE INVERTER AT 4MV KWDLESS OFTEMPERATUEE TIE MAX OC v TAGEOFTHEMODULEATO•CEEXPECTEOTOBE42.9V(D-C-25T)X4I.111VJLIN,7W-42.M. THE SOAR EDGE INVERTER 16 NONNSOATED. NEITHER THE NEGATIVE NOR POSITIVE CONDUCTOR IS GROUNDED ANT) THEREFORE NO DCDEC ISREQUIRED e WMDRATED DC OW"I NECTEPROVIDED WITH MVERTER DISCONNECT ELISTED FOR USEMH SOLAREDGEUL1741LISTEDSTRINGINVERTERS. PV SYSTEM POINT-OFCNNECTION E ONTHE LOAD S1IDE OF SERVICE DISCONNECT. OUTPUT 16 BACKFEDTHROUGH BREAKER N MAINPANEL THE PV BREAEERSHALL NOT BE MARKEDFOR lWE• AND IOAO. i • + THE PJ BRF_AMERSNAIL BE LOCATED AT THEOPPOSITE END Of THE BUSBM FROM THE MAIN BREAKER, CONDUCTOR AND CONDUIT SCHEDULE WIELECTRICAL CALCULATIONS CURITENr{ MRYMG TEMP. CORR. CONDUIT FILL GOUT MAX CVRRENi BASE DERATED TERN ANP.a TERN. TYPICALCONDUCTORCOIDURCONDUCTORSINLONOUR OCPD EGC FACTOR FACTOR CURENT 125%) AMP. AMP TEIJP.RATING TEMP. RATING I 1 tO AWGP RE, FREEEM WA WA 6 AWGBARE. COPPER 0TB(55.0 1.0 15A 1575A SEA 414A 75•C SIA 2 1 10 AWDi 2, COPPER O.SDIAEMT2 WA 10AWGTHWW2, COPPER070(SS'q 10 15A 16.75A 40A JOAA III90A D 1 ITICOP ER FREEAR WAWA TANG BARE. COPPER 075(55'C) 1.0 15A 1075A SSA 41.M1 75•C EGA 4 1 tO AWO TGWNICOPPER O.S OIAEMTx WA 1DAMTMWR2, COPPER 0.75(55•C) 1.0 15A 1615.A 40A 3GM 60'C 90A 5 1 1AWG 111. 06.OAEMT 2 RDA 10AWGTHWH-x. O.BB(9YCy 1.0 IIA 40A fiW S2.8A 60'C AM COPPER COPPER GROUNDING NOTES ALL EQUIPMENT SHALL BE PROPERLY GROUNDED PER THE 1 REQUIREMENTS OF NEC ARTICLES 250 & 690 PV MODULES SHALL BE GROUNDED TO MOUNTING RAILS USING MODULE LUGS OR RACKING INTEGRATED 2 GROUNDING CLAMPS AS ALLOWED BY LOCAL JURISDICTION. ALL OTHER EXPOSED METAL PARTS SHALLBE GROUNDED USING UL• LISTED LAY -IN LUGS. GROUNDING SYSTEM COMPONENTS SHALL BE LISTED FOR 9 THEIR PURPOSE IF THE EXISTING MAIN SERVICE PANEL DOES NOT HAVE A VERIFIABLE GROUNDING ELECTRODE, IT IS THE 4 CONTRACTOR'S RESPONSIBILITY TOINSTALL A SUPPLEMENTAL GROUNDING ELECTRODE. JAC SYSTEMGROUNDING ELECTRODE CONDUCTOR (GEC) 5 SHALL BE A MINIMUM SIZE #8AWG WHEN INSULATED, #6AWG IF BARE WIRE. EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED ACCORDING TO NEC ARTICLE 690.45, AND BE A MINIMUM OF 6 #10AWG WHEN NOT EXPOSED TO DAMAGE, AND #6AWG SHALL BE USED WHEN EXPOSED TO DAMAGE GROUNDING AND BONDING CONDUCTORS, IF INSULATED, 7 SHALL BE COLOR CODED GREEN, OR MARKED GREEN IF 4AWG OR LARGER SINGLE -LINE DIAGRAM PV-3 SCALE: NTS 1NIT ODCGBITHA9 MHI GATEDFpRTHEPBI@D9Iif DEAfABPIGMDEMMOFAROF'!®RbNf WLTAKIWNFR Srb164M11HFNXIGMOETIATo0FY0NtiTHAIECIIINLHCE wTmKLWft1LVLECOf1EL.W0 .MXAnOH5.1FE00LlW6Nr6xalA0 NUT6FREIFI]NPD11 /5A sLBSTI1MfE FORFl11liWPqNANDFA'IDRERMBTAMAM6IMWINIMBTMLFRNVIIMTALLALLEgIIPIENTKACL0110W.E WmWNIIFALTIRBI wSFNurIDrNMWUALS. NORMGNRtlDODIIENi6HMA06E NIERPETFD W AWAY R4T 091NpF9TtiM61RNODttR6 WNNPIFACRRA M6TWIA11(MAWWMSm Lu cn co fif Lu C3 d J O co m uj II' T ALL V P- 90327M Q' ti Q ^. CV Lu M J J co Ll LU c z a O T` Z co SINGLE -LINE DIAGRAM PROJECT ID: 90827 DATE: VA9118 CREATED BY: AF. CHECKED BY: REVISIONS PV-3 DC RACEWAYS O SEENOTE N0.4 (DC RACEWAYS) O JBi - TRANSITION BOX MODEL NOT SPECIFIED O O JB2 - TRANSITION BOX MODEL NOT SPECIFIED O O I1- INVERTER SOLAR EDGESE7SWH-US) 0(D MSP MODEL NOT SPECIFIED O O O O O 10 WARNING PHOTOVOLTAIC POWER SOURCE 3 EACH DISCONNECTING MEANS FORPHOTOVOLTAICEOUIPMENT (JB1, JB2, 11) NEC SECTION 590.17(E) OEACH DEVICEWHERE ENERGIZED, UNGROUNDED CIRCUITS MAY BEEXPOSED DURING SERVICE (At „B2, 11) NEC SECTION 690.35(F) ODC DISCONNECT 01) RATED MPP CURRENT: 18.OA RATED MPP VOLTAGE: 400V MAX SYSTEM VOLTAGE: 480V NEC SECTION690.53 OSOLAR BREAKER (MSP) NEC SECTION786.12PAI'(Sj(9) O2 POINT -OF -INTERCONNECTION OR AT MAIN SERVICE DISCONNECT (MSP) r 1 CAUTION 1 PO'LNtRTOTHIS BULDINGISf C',FROMROOFMOUNTED SOLAR ARRAYS V1 HSAF6i'DtSCON1+ECTS NECSECTION 690.*% OB AC DISCONNECT(CBI IN MSP) MAXIMUMAC OPERATING CURRENT: 32.1A MAXIMUM AC OPERATING VOLTAGE: 240V NEC SECTION MMOANY AC ELECTRICAL PANEL THAT IS FED BY BOTHTHE UTILITY AND THE PHOTOVOLTAIC SYSTEM (MSP) NEC SECTION 706:12P)M O PHOTOVOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN 10 AC SOLAR DISCONNECT (CB1 IN MSP) PHOTOVOLTAIC AC DISCONNECT NEC SECTION 600,1303) LABELING NOTES 1 ALL PLAQUES AND SIGNAGE REQUIRED BY 2014 NEC AND 2015NFPA1WILLBEINSTALLEDASREQUIRED. LABELS, WARNING( S) AND MARKING SHALL COMPLY WITH ANSI Z535.4, WHICH REQUIRES THAT DANGER, WARNING, AND CAUTION SIGNS USED THE STANDARD 2 HEADER COLORS, HEADER TEXT, AND SAFETY ALERT SYMBOL ONEACHLABEL. THE ANSI STANDARD REQUIRES A HEADING THATIS AT LEAST 50%TALLER THAN THE BODY TEXT, IN ACCORDANCE WITH NEC SECTION 110. 21(B). A PERMANENT PLAQUE OR DIRECTORY SHALL BE INSTALLED PROVIDING THE LOCATION OF THE SERVICE 3 DISCONNECTING MEANS AND THE PHOTOVOLTAIC SYSTEM DISCONNECTINGMEANSIFNOTINTHESAMELOCATIONIN ACCORDANCE WITH NEC SECTION 690.56( B). LABEL(S) WITH MARKING,' WARNING PHOTOVOLTAIC POWER SOURCE; SHALL BE LOCATED AT EVERY 10 FEET OF EACH OC RACEWAY AND WITHIN ONE FOOT OF 4 EVERY TURN ORBEND AND WITHIN ONEFOOT ABOVEAND BELOWALLPENETRATIONSOFROORCEILINGASSEMBLIES, WALLS AND BARRIERS. THE LABEL SHALL HAVE 3/ 1Y TALL LETTERS AND BE REFLECTIVE WITH WHITE TEXT ON A RED BACKGROUNDLABEL(Sj WITH MARKING, 'PHOTOVOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN,' SHALL BE LOCATED 5 AT POINT -OF -INTERCONNECTION OR AT MAIN SERVICE DISCONNECT THELABELSHALLHAVE3/8' TALL LETTERS AND BE REFLECTNE WITH WHITE TEXT ON A REDBACKGROUND P- 90327 W Cn co W W O J cn J a Z 1 O LL 0 0 Qo c WHSAFETY LABELS PV-4 P-90327G RIDGE WIII l I I I I W CIO p N W c) NOTES ilrQ y/q11oil I milli a U) o J J Vi LL W p Z_ m a O O Z RAFTER LOCATIONS ARE APPROXIMATE. ACTUAL 1 LOCATIONS MAY DIFFER AND CONTRACTOR MAY NEEDIII I p TO ADJUST MOUNT LOCATIONS. IN NO CASE SHALL THE MOUNT SPACING EXCEED "MAX. MOUNT SPACING' SAVE ATTACHMENT PLAN (OBLIQUE PROJECTION) V-5.1 SCALE: 3/16' = 1' ATTACHMENT PLAN DOC ID: 90327-112269-1 DATE: 619f18 CREATOR: A.F. REVIEWER. REVISIONS PV-5.1 ROOF PROPERTIES ROOF MATERIAL COMPOSITION SHINGLE (1 LAYER) SLOPE 8112 (33.7°) MEAN ROOF HEIGHT 26FT DECK SHEATHING 7116' OR THICKER OSB OR PLYWOOD CONSTRUCTION TRUSSES (2X4 TOP -CHORD), 241N OC MODULE MECHANICAL PROPERTIES MODEL D-CELLS O.PEAK BLK-G4.1 300 DIMENSIONS (AREA) 66.71N X 39.41N X 1.31N (18.0 SO FT) WEIGHT 41.4L8 MOUNTING SYSTEM PROPERTIES MAX. ALLOW. RAIL SPAN 108.OIN (ZONES 1, 2, AND 3) MAX. MOUNT SPACING 48.OIN (ZONES 1, 2, AND 3) MAX. ALLOW. CANTILEVER g3.21N (ZONES 1, 2. AND 3j GROUNDING AND BONDING INTEGRAL GROUNDING CERTIFIED TO UL 2703REQUIREMENTS P-90327 LLI I 1 C/) Lu ti Q Mw i i I O a_ J l U) LL. Z ot I i O vJ LL Q Q I E I I I I EAVE ATTACHMENT PLAN (OBLIQUE PROJECTION) ATTACHMENT V-5 SCALE: 1/4" = 1' PLAN DOC ID: 90327-112269-1 DATE. 619/18 CREATOR: A.F. REVIEWER: REVISIONS F1 PV-5.2 ROOF PROPERTIES ROOF MATERIAL COMPOSITION SHINGLE (1 LAYER) SLOPE 8112 (33.7') MEAN ROOF HEIGHT 25.4FT DECK SHEATHING 711fi' OR THICKER OSB OR PLYWOOD CONSTRUCTION TRUSSES (2X4 TOP -CHORD), 241N OC MODULE MECHANICAL PROPERTIES MODEL 0-CELLS O.PEAK BLK-G4,1 300 DIMENSIONS (AREA) 65.71N X 39.41N X 1.31N (18.0 SO FT) WEIGHT 41.4LB MOUNTING SYSTEM PROPERTIES MAX. ALLOW. RAIL SPAN 108.OIN (ZONES 1, 2, AND 3) MAX. MOUNT SPACING 48.OIN (ZONES , 2, AND 3) MAX. ALLOW. CANTILEVER 43.21N (ZONES 1, 2, AND 3) GROUNDING AND BONDING INTEGRAL GROUNDING CERTIFIED TO UL 2703 REQUIREMENTS NOTES RAFTER LOCATIONS ARE APPROXIMATE. ACTUAL 1 LOCATIONS MAY DIFFER AND CONTRACTOR MAY NEEDTOADJUSTMOUNTLOCATIONSINNOCASESHALLTHE MOUNT SPACING EXCEED "MAX. MOUNT SPACING" ROOF PROPERTIES ROOF MATERIAL COMPOSITION SHINGLE (1 LAYER) SLOPE 8112(337°) MEAN ROOF HEIGHT 23.5FT DECK SHEATHING 7116' OR THICKER OSB OR PLYWOOD CONSTRUCTION TRUSSES (2X4 TOP -CHORD), 241N OC MODULE MECHANICAL PROPERTIES MODEL Q-CELLS O.PEAK BLK-G4.1 300 DIMENSIONS (AREA; 65.71N X 39.41N X 1.31N (18.0 SO FT') WEIGHT 41.4L8 P-90327 i iE LLJ U) i MOf Q ( yea W ui M J J 1 I I I I d CANTILEVER Cn LL f I j Q W I I E i < _z O 0 I I u) o z I I I j Lu ( ATTACHMENT PLAN (OBLIQUE PROJECTION) (O V5 3 SCALE: 1/4° = 1' ATTACHMENT PLAN DOC ID'. 90327-112269-1 DATE. 619118 CREATOR: A.F. REVIEWER. REVISIONS PV-5.3 LFAVE L MOUNTING SYSTEM PROPERTIES MAX. A P-90327 IRONRIDGE PV MODULE XR1DO RAIL QUICKMOUNT QMLM COMP, SHINGLE ROOFING MATERIAL i .. Lu f } FLASHING INSTALLED RAIL CLAMPING ZONE — / BETWEEN UPPER AND C/) tiLOWERCOURSEOFolf SHINGLES w cv c') 3: Lu LAG SCREW INTO ROOF OLLJJ STRUCTURAL MEMBER w L1J i Z a-- c ATTACHMENT DETAIL (TRANSVERSE VIEW) a O PV-6 SCALE: NTS 0 z l G Q NLu s— 0_ RACKING ELEVATION (TRANSVERSEVIEW) Pv 6 SCALE: NTS PV MODULE IRONRfDGE XRiDDRAIL D QUICKMOUNT QMLM o COMP SHINGLE ROOFINGMATERIAL ATTACHMENT tDETAILS DOC ID: 90327-112269.1 DATE: 619118 CREATOR: A.F. ffi---- RAFTERSPACNG ATTACH6 NT SPAN — LAGSCREWkMENTO ROOF REVIEWER: STRUCTURAL MEMBEP. REVISIONS s ] RACKING ELEVATION (LONGITUDINAL VIEW) _ D ATTACHMENT DETAIL (LONWUDINALVIEWj PV 0 SCALE: NTS PV 8 SCALE SCALE PV-6 MOUNTING NOTES FLASHING SHALL. BE APPLIED M ACCORDANCE WITH MANlffACYURERS PRINTED MS7RUCTIDNS. tFTHERE 15 ANY CONFLICT BETWEEN WHAT IS DEPICTED HERE AND INSTRUCTIONS PROVIDED BY THE MANUFACTURER, MANUFACTURERS'INSTRUCTNNiSSHALL 5UPERCEDE z 2 3 2 P-90327 N L W I- i 1 1 1 Ix W O Q N W ch J J C LL I 1O ROOF ACCESS POINT, PER NFPA1 11.12.2.2.1.3 o Fl Q W W Q Z c' a O ZQ PV MODULES INSTALLED ON ROOF WITH IRONRIDGE ROOF MOUNTING SYSTEM. THE MOUNTING SYSTEM IS OCLASS A FIRE RATED ON A 8/12 SLOPED ROOF WHENINSTALLEDWITHTYPE1OR2MODULES. THE Q- 1 FIRE SAFETY PLAN CELLS Q.PEAK BLK-G4.1 300 IS TYPE 1. Q CD PV-7 SCALE' 1 ° = 20' O 3.0 FT. WIDE SMOKE -VENTILATION SETBACK, PER NFPA 111.10.2.2.2.2 4 CABLES, WHEN RUN BETWEEN ARRAYS, SHALL BE ENCLOSED IN CONDUIT. FIRE SAFETY PLAN DOC ID: 90327-112269-1 DATE: 19118 CREATOR: A.F. REVIEWER: REVISIONS PV-7 FIRE SAFETY REQUIREMENTS EXTERIOR -MOUNTED DC CONDUITS, WIRING SYSTEMS, AND RACEWAYS FOR PHOTOVOLTAIC CIRCUITS SHALL BE LOCATED AS CLOSE AS POSSIBLE TO THE RIDGE, 1 HIP, ORVALLEY, AND FROMTHE HIP OR VALLEYASDIRECTLYASPOSSIBLETOANOUTSIDEWALLTO REDUCE TRIP HAZARDS AND MAXIMIZE VENTILATION OPPORTUNITIES (NFPA 1 11.12.2.2.4.1) ROOF ACCESS POINTS SHALL BE DEFINED AS AREAS WHERE FIRE DEPARTMENT LADDERS ARE NOT PLACED 2 OVER OPENINGS (WINDOWS OR DOORSI, ARE LOCATED AT STRONG POINTS OF BUILDING CONSTRUCTION, AND ARE IN LOCATIONS WHERE THEY WILL NOT CONFLICT WITH OVERHEAD OBSTRUCTIONS (TREE LIMBS, WIRES, OR SIGNS). (NFPA 1 11.12.2.2.1.3) PHOTOVOLTAIC MODULES SHALL BE LOCATED IN A MANNER THAT PROVIDES A 3 FT WIDE CLEAR ACCESS PATHWAY FROM THE EAVE TOTHE RIDGE OF EACH 3 ROOF SLOPE WHERE THE PHOTOVOLTAIC MODULES ARE LOCATED. THE ACCESS PATHWAY SHALL BE LOCATED AT A STRUCTURALLY STRONG LOCATION OF THE BUILDING, SUCH AS A BEARING WALL, EXCEPT WHERE ADJOINING ROOF PLANES PROVIDE A 3 FT WIDE CLEAR ACCESS PATHWAY. (NFPA 1 11.10.2.22.1.1) 4 PHOTOVOLTAIC MODULES SHALL BE LOCATED NO LESSTHAN3FTBELOWTHERIDGE. (NFPA 1 11.10.2.2.2.2) M perEer. d ' MM With its top performance and completely black design the new 0,PEAK BLK-G4.1 is the ideal solution for all residential rooftop app!ications thanks to its innovative cell technology UNTUM. The world -record cell design was developed to achieve the best performance under real condi- tions - even with low radiation intensity and on clear, hot summer days. LOW ELECTRICITY GENERATION COSTS Higher yield per surface area and lower BOS costs thanks to higher power classes and an efficiency rate of up to 18.3%. INNOVATIVE ALL-WEATHER TECHNOLOGY Optimal yields, whatever the weather with excellent low -light and temperature behavior. ENDURING HIGH PERFORMANCE Long-term yield security with Anti-PIO Technology', Hot -Spot -Protect and Traceable Quality Tra.QTM. EXTREME WEATHER RATING QGfLLS 3 High-tech aluminum alloy frame, certified for high snow arspR,aRAmespY' 540OPa) and wind loads (4000Pa) regarding IEC. 20t6 MAXIMUM COST REDUCTIONS Up to 10% lower logistics costs dueto higher module capacity per box. phnenn O A RELIABLE INVESTMENT Inclusive 12-year product warranty and 25-year l linear performance guarantees. APT test conditions: CNIs M .1500V Against grounded, with conductive no- tal fail covered module surface, 25'C. THE IDEAL SOLUTION FOR: 168h See data had on rear for further Irformalon. Engineered in Germany Q CELLS SPECIFICATIONMECHANICAL Fomwl 65.7in , 39.4 n x 1.26in (including /reme) G 670 mm IOOOmm x 32nm) r - r Weigtd 41.45 lb,(18.8 kill a•ersrrnm•xar From Co., 0.13in (3 2mm) thermalty prestressed glaswith an!i-flation technology Back Col., Crmposite film w.r aawr-i ' Frame Black anal zutl aluminum Cell 6 x 10 monovystalline QANTUM solar cells - •. rr I uncle. bus 2,60-3.031, . 4 37 3.54 r x 0.59-0.75m (66-77 mm x L1:-90nm x 15-19mm). Protection class IP67, with bypass diodes •...r,...a. """" a' I Cable 4mm-Sal r,able (+)a39.371 (1000-1 1- 1a39.37,n GCOOmm) --' Lmmecier Nulh-Contact NC4 or MC4 intdateable. IPGB eao•.r I ?"sur MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS. S TC(POWER TOLERANCE +5W / -aW, Power at MW Pe„ Iwl 290 295 300 Seen CbcaN Consul I,, Al 9.63 9.70 9-77 - 6 open circuit Village- Vw IV] 39.19 _. 39.48 39.76 s Commit at MPP• _ - _ _ I- IA) 9.07 9.17 9,26 Yaibie al MPP' V_ IV) 31,96 32.19 32.41 Efficiency, 9 1%1 17.4 217.7 _ _ 218.0 MINIMUM PERFORMANCE AT NORMAL OPERATIVE CONOI 1i0N5, NOC' Power m AIPp' P,„. Im 214.4 218.1 221.8 E Shan chusil Co... Ix [Al - 7.77 7.82 788 m . Open Cilceit YuOage' Vw IVI 36.6°.... -. 36.92 .'7 19 Carters at MPP' I_ [A] 7.12 720 7.27 Voltage at Al Vwr IV]. _.. 30.12 30.3C 30.49 bDO ' z aN i s M slc a a sac eosw Na7 hol., ,> ,iwwm n.yeme iZ A.. least 98% rA.withal Pew, dunna nm Year. e` aw - - -- . 1 $3AIt -tor , .6% nominal powup 110 mare. y At 03.bxainw.inaeb up l ppl. 25 ywrs. Alldata with.n rrwamx, nMltpl,anpes 5 - - .. _ .... - ..... ._ _. R Full wermordes In ace,dante with the wawanlyW eemm of the D CELLS sales aPnisatlan W yourrespechw countr!c wcaewAYiWM Typical mpduk TC can once urdes low irndlance cend:lions in efAP' p,mp,narirmsicr<rlamonar2s•c.lolmwmlry. 1ffMPEitATUall COEFF, C ii T ,-Is G flnotlac v 1%/KI +064 Tempulame L fl tatY d I%/Kl 028 Temporal C efirciei I of P„„ y (%/K) -0,39 Normal op -brit Call iempernme MOCT I'F) : i3 z 5 4 (45 x3'C) ' PROPERTIES FOR SYSTEM DESIGN Ms.:mom system Voltage V_, IVI I COO (IEC)1 1000 (UL) Safely Class . _ _ _ _ _ _ 11 Mavem, Series Fuse Ill IA DCI 20 Fire Rating CiiECi1''PE 1(JLi nes g. load, push (UL)l Ilbs/,V 75 i3600P 1 Permitted module temparalma -40 F up to +1a5`F an "Mims... 4uty (-40'C up to+85'Cl Denlgn load, pull WILY [Ill 56. 6 !2666Pa. see in tat a or man'aal . AND CERTIFICATES PACKAGING INFORMATION UL 1703: VIDE Ouahty Tested, CE compliant: Number at Modules par Pallet 32 IEC 612151Ee.21: IEC 61730 (Ed 1) application class A Humber or Pallets per 53' Cainainer 30 AeNumber or Pallets per 40' Container 26 COVE \ E CU,S PalletDimensions (I x Wx H 1 68.7 in 45.3in x 46.rim 1745mm x 1150mm x1170mm) Partial W a gM 1435lbs (651 Ile) NOrFInsWlatirn insWplloiu nazi be' allawetl. See Iha installation and Dooming menus! , amend wr taeaniul servxe departmem for turth, InfamaHanon eppaved inmallehrn and use or 1ba pmduct. Plural a CE L3 America me 300Spectrum Cent, Rive, Suite 1250, brine, CA 92618, USA I I a 1 949 74859961 EMMLI WEa wow. a-Wisus Superior effid Wiligat" au types of rnadiiTcsr sinatchlo's5e4, ommarf tiuri gt ra Ftex4ble system design for 0,41(tmum space u0blation r Fast installation with a single bolt - Next generation maintenance with module -level monitoring Compliant with arc fault protection and rapid shutdown NEC requirements (when instalied as Da rt of the so arEdge system) Module -level voltage shutdown for installer and firefighter safety USA (.ANADA-GLRMANY IIx-ITAIMM NETHLRIANDS-*ANLHiNA-AVSTNALIA-rSRAE1: FRANCI. RL.LOW ILIRYEY-IN0IAAVLGARIA ROMANIA HI3N(5ARr w.vw.soiarcdge. SWEDEN-50UTH AFRICA-POWYD{2EO1 REPVeUC solar=eeSolarEdge Power Optimizer Module Add On for North America P320 / P370 / P400 / P405 / P505 P320-_-P370 P400 P405 OPTIMIZER MODEL if," Nitrlroumr (lorfi r`POMiOf i (fa72&gF-it frrfh!n Sim P505 rwhlitt— pYF+Icalnwduie..en PatlSAn'!i GP<t-( 60-d 71 elle`ud;tiP J nvidYlrf) nbMlirf} nnM moEltnroEl.bal FatediApuF.DC POWIfI. ...-. 370 I 4011 4(li.. W .... Absolute Maximum Input VMtage la 60 W 125 e3 tNc t7oc at bwest ltmperatum) ....; MPPTOPtgtIn6.RaABe .... v..r= ............ 9_•a0 525 10.5 _ 125 -6i... 1A0[--. Mmmum Start Circuit eflt (ift! 10 t 14 .........A-.... Mawmum DC Input QNrent f.. S it fs ... l. - .17.5 .... Etfiden(7Maim wngnree 99S _ Elfirkncy _. ...... i.. 9dg _. E. 986. . 0vervdta Cat - N i (PnWF.Rn>'T'IMIXE'tt YDMMFGTEn'1'873PfgATtJdF+5Qfl4kED6EINVYNTER} °: r IN%TP,{iE tAUiQ $711{I1ROW(POWER. O> 71MI7FA WSCONNECTEP FROMSOIAAEC-CF WVi'RTEAOR SniAREDGE INVERT-tR OFP safety output vorlage W Puwer vd o t5lrdsr EMC ECC Par115 Class B IEC61000b2 IEC'6100063 Safety .... .1•• IEC6210S1(d—Ilij y) UL7741 I.... AMIC 1!A MadnAnf Albw(M SysKm Vcllige t000ATZOWAN CUIrIpalibk rrNerleR I ARSolarEOge Sxl lePhaseaM Tthee Ptrake irkrerters Ormensions(W x Lx H) 12.. 152xffi lSx 5.91 x11 f2ax1-i21.42 k- 6 12gx15x232 1 tmrlin I Sx591x147 5. S.972Sx597x L46_ 5a5.97x13I.-- WnBM').^dr 6les........... ............ 750/1. . MS/1.9 ..... 1064/23-....1. input CawrtUa ....... 1 .... ... output Wire Type/Canrxxtw I Double hovlatetl MCA Output Wire Length 095/3.0,. L2/39 ..... mtfr Operatirrp Tempenturs Ranpe 185.... ......... C('F- Praerbon N0-0. ....... ......... P6a%REMA6P.. Relative NurnWty......... ............i uarasrr.Ae rm dkre nodk. ra.IhAedgn.9Nra+xr;e...e,e...e. ra aM m..®rriotfA ma.a saYrEAp MiNmumString Length lP32QP3H;P4U(I .............. .---._. lo._...... 5... ...... .. Power optimirersi......IPA_O5./P505 ...... .........- . `. ............................................... AAadmum string Length 25 25 5001Powerpptlmirers).................... _..... ..-----.................,.... _..-__...... -... ................----. 570D(600D w)tlt l Marinkun Power perString SEM001F17s, I 5250 600D 12750 W SE10000E4 ....................--......-.- ........ Para1W Strings of LMeerenf tengLlrs YesaOYIenUliunS fpbrflAd .nNEGiry infanr bnrNerM MrAJ/vn....arWeennr`JINAAaw/Nn/anrrl fMt_..odl. Kkh ear albwpu inn arlA:r5e5 wRNv)m/v.lomim/WW, .W rrN9.YA mr. rMn 30 yNMm.oem .n mrw by r krt..-. a ... +w ..lfWbrve.Fr Mvr+w .m1 solar=@@ Single Phase Inverters for North America SE300OH-US/SE3800H-USiSE500OH-USi SE600OH-US/SE7600H-USiSE10000H-US 1 i -A-Mr.-Jo i Opt1!'Elixed 1n5tailation with KD Wave techno Extremely small High retiabliq without any 64ect7tstytte capacitors Built-in module -level monitoring Outdoor and Indoor Installadon t`. Optional: Revenue grade data, ANSI C12.20 Gass 0.5 t0.5% acsurac now WOVl tK#(ANAOA dfANANT 011TAlt IMF NETIITNrAxOS MVANt MA A±STHAUA [SRAkL1xMMt'rNCl letOar,FY 6rnIF 4M!kxO4MN MVYK.nIIiiWEMN w .s leredg-s kQnM MOVA-POEM0 CHOI It"01RH solar=@a Single Phase Inverters for North America SE3000H-US!SE3800H US/SE500GH-US/ SE6000H-US!SE760OH-US/SE10000H-US S£3IX0011 US SF3600H US SESIMOH-US S1,60001f tfS 5E760UN-US 5Ei000DN-US Rat dAfPower9!!tpot Max 300c 1a00 ' ,oW 6000 I 7600 IOOIX VA . AC POvrer Output. 3tMNf Mo 000 E000 76D0 100IX] VAACOutputYoRagcMinJtorrr. I f I. Maxxnrmi Continuous Ompul 12 5 ES.. I........ Curten[ir2a0V_ ..... 21 32 I 42I251I A GFDI_Threshold I. .. ......: ty ng, tslarxlirtgUti' Monitwi PrOteCtian. CWnlry Configulable yg . M?.— DC Power 4650 i..... 5900 _ ...1...... 7750 l 9300 [ 11800— lmer-Mss Ungrounded - - .. _ yrs M., s NlaxxFnum Input votage 4e0 - ....... Vx NIpWrIA DC Mpul voltage fiBO ...... ... 400Max4nummpulCureM®240Y e 5 IO S .I. 135 20 27 1 Ack Max Input short Urcutt Gxre t I ........ 45 Adc ReveTxcPoUdty Plotechon .. 9es GrourxlFau813oW0onOEKection Mxmum Inverter ER99 99.. M hitlme Power Consum 2 5 Supparhd Communiudon Mtertaes R5485, Ethemel, Lg8r4 (oPdonatl. CaT8u1Tr (oplianall Revenue Grade Data, A1751 C12 20 RapidShudown - NEC 2014and 90 12 2o1763.1 Autumahc Rapid Shutdown upon AC Gild OkrOrlrtect ety ,_ ... ... _ Ui141 Ut14l SA lA1E098C5A C221, Carudfan AFOaccwdingto ri! t ] Cxid ConneCdnn Standards I .. ......... IEEE1547 Ruk 2l, tWk EmtuiomFCCPart15ansBAC output Conduit Sim /AWG axe 3/4"MM. "/20.4 A1NGDC Input ConduitSize/4 of strigc TAWG Rorie 3/4'ma4mdm/1-I 9hMp/14-6AWG Ii nYdmun 1- 3 *kW / IIb..+. i......-.... Mmensi pq with5ar Sviitot, 21.3 x4.6xj 11xWxD1 17.7x14.6x6.e /450x370x174 73/540x370 In/mm W.. gM WMSakly Switch ._ -.. 22/26 ....I. 25 /.11A I_ .26.2/11.9 3&6(17:6..1..9i..... NO[ se 1...&. NaturatConvectlon ClpepahngT+.? fnperXrwe aerie_ .. NatunlcmFeecdon t:+ m.i4D(25 to so^"(w0•F/a0'C_pt!mC• PTotectianRating ... ..... . I NEMA 3NJInverter wHh SaFay 9witd!............................ NFsoWrr M / 0+0 lse mwrCSYrEde+.npen ary m+4rrM mrlemxl.r xxUNFrdMwwrabWFmMmaJWi:.nlrikM..-im.*.w.. 9.m,w. Ww.rM.rylr MiJ0ysimrYm.Y>dN®INM IRONRIDGE Flush Mount System — XRRailsC Built for solar's toughest roofs. IronRidge builds the strongest mounting system for pitched roofs in solar. Every component has been tested to the limit and proven in extreme environments. Our rigorous approach has led to unique structural features, such as curved rails and reinforced flashings, and is also why our products are fully certified, code compliant and backed by a 20-year warranty. Strength Tested All components evaluated for superior structural performance. Class A Fire Rating Certified to maintain the fire resistance rating of the existing roof. UL 2703 Listed System Entire system and components meet newest effective UL 2703 standard. PE Certified Pre -stamped engineering letters available in most states. Design Assistant UOnline software makes it simple to create, share, and price projects. XR10 Rail Qa A low -profile mounting rail for regions with light snow. 6' spanning capability Moderate load capability Clear & black anod. finish Clamps & Grounding r' Universal Fastening Objects bond modules to rails. Fully assembled & tubed Single, universal size Clear & black finish Attachments , XR100 Rail XR1000 Rail Bonded Splices Ellm - The ultimate residential A heavyweight mounting All rails use internal splices solar mounting rail. rail for commercial projects. for seamless connections 8'spanning capability 12'spanning capability Self -drilling screws Heavy load capability Extreme load capability Varying versions for rails Clear & black anod. finish Clear anodized finish Forms secure bonding Stopper Sleeves Snap onto the UFO to turn into a bonded end clamp. Bonds modules to rails 6 different sizes Clear & black anod. finish Grounding Lugs Connect arrays to equipment ground. Low profile Single tool installation Mounts in any direction Micraimetter Kits Mount Mls or POs to XR Rails_ Bonds devices to rals Kit comes assembled Listed to UL 2703 FlashFoot2 Slotted L-Feet Bonding Hardware Flush Standoffs Flash and mount XR Rails Drop -in design for rapid rail Bond and attach XR Rails Raise Flush Mount System with superior waterproofing. attachment. to certified attachments. to various heights. Twist -on Cap eases install Secure rail connections T & Square Boft options Works with vent flashing Wind -driven rain tested Slot for vertical adjusting Nut uses 7/16" socket 4" and 7" lengths Mill & black finish Clear & black anod. finish Assembled & lubricated Ships assembled nesources Design Assistant . NASCEP Certified Training 20 Year Warranty Go from rough layout to fully A` F; Earn continuing education credits, f Twice the protection offered by engineered system. For free. while learning more about our systems. competitors. Go to IronRidge.com/desigtn Go to tronRidge.comttzaining ae20?B k(43131&i'.Sn^ AHi,g§1e3EtY•s(7.Yiri w•vwxonts9¢p.P,OIfl arCak 7-B9b$',tT-372. w+ir rttGleinfiWmRS,o.Jhsn+It2*3 IRON RIDGE 1495 Zephyr Avenue 1Hayward, CA 495 Zephyr Avenue 94544 AML Hayward, CA 94544 IRONRIDGE 1800-Zi795 13 I IronRidge.comIronRidge.com Attn: Corey Geiger, VP New Markets, IronRidge Inc. Date: December 20", 2017 Re: Structural Certification and Span Tables for IronRidge Flush Mount System This letter addresses the structural performance and code compliance of IronRidge's Flush Mount System. The Flush Mount System is a proprietary rooftop mounting system used to support photovoltaic (PV) modules installed in portrait or landscape orientation and set parallel to the underlying roof surface. PV modules are supported by extruded aluminum XR Rails and secured to the rails with IronRidge mounting clamps. The XR Rails are side mounted to a selected roof attachment with 3/8" stainless steel bonding hardware and then attached directly to the roof structure or to a stanchion that is fastened to the underlying roof structure. Assembly details of a typical Flush Mount installation and its core components are shown in Exhibit EX-0015. The IronRidge Flush Mount System is designed and certified to the structural requirements of the following reference standards for the load conditions and configurations tabulated in the attachea span tables: ASCE/SEI 7-10 Minimum Design Loads for Buildings and Other Structures (ASCE 7-10) 2015 international Building Code (IBC-2015) Florida Building Code 6' Edition (2017) Building 2015 Aluminum Design Manual (ADM-2015) The tables included in this letter provide the maximum allowable spans of XR Rails in the Flush Mount System for the respective loads and configurations listed, covering wind exposure categories B, C. & D, roof zones 1, 2 & 3, and roof slopes from 01 to 45°. The span tables are applicable provided that the following conditions are met 1. Span is the distance between two adjacent roof attachment points (measured at the center of the attachment fastener) 2. The underlying roof pitch, measured between roof surface and horizontal plane. is 450 or less. 3. The mean roof height, defined as the average of the roof eave height and the roof ridge height measured from grade, does not exceed 30 feet. 4. Module length shall not exceed the listed maximum dimension provided for the respective span table and module width shall not exceed 40". 5. All Flush Mount components shall be installed in a professional workmanlike manner per IronRidge's Flush Mount installation manual and other applicable standards for general roof construction practice. 0 2017 IronRidge, Inc. FL Flush Mount System certification Letter - 1 The span tables provided in this letter are certified based on the structural performance of IronRidge XR Rails only with no consideration of the structural adequacy of the chosen roof attachments, PV modules, or the undertying roof supporting members. It is the responsibility of the installer or system designer to verify the structural capacity and adequacy of the aforementioned system components in regards to the applied or resultant loads of any chosenarray configuration Sincerely, No Gang Xuan, PE, LEER AP Senior Structurai Engineer 02017 ImnRidge, inc R.L. 0 f; 1 O p• $ I22o i j FLFlush Mount System Centicaiwn Letter - -s 1/r IRONRIDGE Background All rooting products are tested and classified for their ability to resist fire. Recently, these fire resistance standards were expanded to Include solar equipment as part of the roof system. Specifically, this requires the modules, mounting hardware and roof covering to be tested together as a system to ensure they achieve the same fire rating as the original roof covering. These new requirements are being adopted throughout the country in 2016. lronRidge Certification IronRidge was the first company to receive a Class A Fire Rating —the highest possible rating —from Intertek Group plc., a Nationally Recognized Testing Laboratory. IronRidge Rush Mount and Tilt Mount Systems were tested on sloped and flat roofs in accordance with the new UL 1703 UL 2703 test standards. The testing evaluated the system's ability to resist flame spread, burning material and structural damage to the roof. Refer to the table below to determine the requirements for achieving a Class A Fire Rating on your next project. Class A Fire Rating Frequently Asked Questions Test Setup Sitar Module, Solar modules are siren a Type classification based on their matehale and corretnrNon. MounOng system Mourifing a tested as part of a system that includes type -tested nodules and tiro -rated roof mvenng Roof Covering Rod covering products are given a Fire Class Rating d A. B or C based do "r rested fire esiswce. Burning Brand Test A burning woodenblockis placedon module as aIwt blows 0 12 mph Flame sand be saes on urdetslda of roofwitMn 90 minutes. Spread of Flame Test s- Flame at souther, edge ofroot a aimed up the rod as a tan blows a! 12 mph The Name canrd spread 6 feet or more n 10 mrsrtea. Flush Mount Any Slope Lai 1 Type 1, 2, & 3 j ClassA Tilt Mount 56 Degrees III Type 1, 2, & 3 i Class A LOJ i nova AtreeW eygsra an0e eMlaamQ®eA, B, What is a "module type"? The new UL1703 standard introduces the concept of a PV module type, based on 4 construction parameters and 2 fire performance parameters. The purpose of this classification is to certify mounting systems without needing to test it with every module. What roofing materials are covered? All fire rated roofing materials are covered within this certification including composition shingle, clay and cement tile, metal, and membrane roofs What if I have a Class C roof, but the jurisdiction now requires Class A or S? Generally, older roofs will typically be "grandfathered in", and will not require re -roofing. However, 6 50% or more of the roofing material is replaced for the solar installation the code requirement will be enforced. Where is the new fire rating requirement code listed? 2012 IBC: 1509.7.2 Fire classification. Rooftop mounted photovoltaic systems shall have the same fire classification as the root assembly required by Section 1505. Where is a Class A Fire Rating required? The general requirement for roofing systems in the IBC refers to a Class C fire rating. ClassA or B is required for areas such as Wildland Urban Interface areas (WUI) and for very high fire severity areas- Many of these areas are found throughout the western United States. California has the most Class A and B roof fire rating requirements, due to wild fire concerns Are standard mid clamps covered? Mid clamps and and clamps are considered part of the PV "system", and are covered in the certification More Resources Installation Manuals Visit our webs to for manuals that include UL 2703 Listing and Fire Rating Classification. Go to IronRidge.com Tech Brief What attachments and flashings are deemed compatible with Class A? Attachments and their respective flashings are not constituents of the rating at this time. All code -compliant flashing methods are acceptable from a fire rating standpoint. What mounting height is acceptable? UL fire testing was performed with a gap of 5", which is considered worst case in the standard. Therefore, the rating is applicable to any module to roof gap. Am 1 required to install skirting to meet the fire code? No. IronRidge achieved a Class A fire rating without any additional racking components. What determines Fire Classification? Fire Classification refers to a fire -resistance rating system for roof covering materials based on their ability to withstand fire exposure. Class A - effective against severe fire exposure Class B - effective against moderate fire exposure Class C - effective against light fire exposure What if the roof covering is not Class A rated? The IronRidge Class A rating Yell not diminish the fire rating of the roof, whether Class A, B, or C What tilts is the Litt mount system fire rated for? The tilt mount system is rated for 1 degrees and up and any roof to module gap, or mounting height_ Engineering Certification Letters We offer complete engineering resources and pre -stamped certification letters. too to Irfln lidge.com I Ie i+'d rCJ'.44 ':..A!, rigi:.s. ,fu.Yr:Lcvwwirsh„dgt .o r. rr c:+ll:r-Y(+. : NODULE i The Flush Mount System may be used to ground and/or mount a PV module complying with UL 1703 only when the specific module has been evaluated for grounding and/or mounting in compliance with the included instructions. Unless otherwise noted, "xxx" refers to the module power rating and both black and silver frames are included in the certification. Modules with 35. 40, or 45mm frames and model identifier aaSM66yyPzz-xxx; where "Wis CH f, Astronergy Solar or A; "W is either 10 or 12; and "zz" is blank or (BL). Frameless modules with model identifier CHSM6610P( DG)-xxx. r-- Axhec Modules with 35 or 40mm trainee and model identifier AC-xxxY/aa-ZZ; where "Y" is M or P; "as" is 125 f or 156; and "ZZ" is 54S, 60S or 72S. Modules with 35 and 40mm frames and model identifier CSbY-xxxZ; where "b" can be 1, 3 or 6; "Y" can Canadian Solar be K. P. U, V, or X; and "Z" can be M, P, AG, MS, PX , M-SD, P-AG, P-FG or P-SD, MS -AG, MS-FG, or I MS - SD. Frameless modules with model identifier CSbY-xxx-FG; where "b" can be 3 or 6; "Y" is K. X, or P; and "Z" can be M-FG or P-FG. ET Solar Modules with 35, 40, or 50mm frames and model identifier ET-Y6ZZxxxAA; where Y' is P, L, or M; "ZZ" Is 60 or 72; and "AA" is WB, WW, BB, WBG, _WW_G, WBAC, WBCO, WWCO, WWBCO or BBAC. Modules with 35, 40, or 50mm frames and model identifier FXS-i=YY--ZZ; where "xxx" is the module Flex power rating; "YY" is BB or BC; and "ZZ' is MAA/ B, MAA1 W, MASI W, SAA1 B, SAA1 W, SACi B, SAC1 W, SAW W, SBA1 B, SBA1 W, SBC1 B, or SBC1 W. j Modules with 35 and 40mm frames and and model identifier GCL-a6A Y xxx; where "a" can be M or P; GCLand 'YY" can be 60. 72, or 72H.- GigaWatt Solar Modules with 40mm frames and model Identifier GWxxxYY; where -re is either PB or MB. j Hanwha SolarModules with 40, 45. or 50mm frames andmodel identifier HSLaaP6-YY-1-xxxZ; where'aa" is either 60 L or. 72; "YY" is PA or PB; and "Z" is blank or B. Modules with 32, 35, 40, and 42mm frames and model Identifier aaYY-ZZ-xxx; where "as" can be O. or B.: ' YY" can be PLUS, PRO, PEAK, LINE PRO, LINE PLUS, or PEAK DUO; and "ZZ" can be G3, G3.1, Hanwha 0 CELLS G4 G4.1, L-G2, L-132.3, L-G3, L-G3.1, L-G3y, L-134, L-G4.2, L-G4y, LG4.2/TAA, BFR-G3, BLK-G3, i BFR- G3.1, BLK-G3.1, BFR-G4, BFR-G4.1, BFR G4.3, BLK-G4.1, G4/SC, G4.1/SC, G4.1/rAA, G4.1/ MAX, BFR G4.1rrAA, BFR G4.1/MAX, BLK G4.1frAA, BLK 04.1/SC, EC-G4.4, G5, BLK-05, L-G5.2, or L- G5.2/H. Helfehe Modules with 40mm frames and model identifier YYZZxxx; where "YY" is 36, 60, 72, or 96; and "ZZ' is 1 M. P, or MBLK Hyundai Modules with 35, 40 and 50mm frames and model identifier HiS-YxnU; where "Y" can be M or S; and 3 ZZ" can be MI, MF, MG, SG, RI, RG(BF), RG(SK), TI, or TO. Itek Modules with 40 or 50mm frames and model identifier IT-xxx-YY; where W' is blank, HE, or SE, or SE72. Modules with 35, 40 and 45mm frames and model Identifier JAyyzz-bb-xxx/aa; where W can be M. P, JA Solar M6 or P6; "zz" can be blank, (K), (L), (R), (V), (BK), (FA), (TO), (FA)(R), (L)(BK), (L)(TG), (R)(BK), (R) TG), ( V)(BK), (BK)(rG), or (L)(BK)(TG); "bb" can be 48, 60, 72, 60SO1 or 72501; and "aa' can be MP, SI, SC, PR, RE, 313B, 488, 48B/RE, SBB. Modules with 40mm frames and model Identifier JKMYioo2Z-aa; where "Y" Is blank or S; "ZZ" is P, Jinko PP, M; and "as" is 60, 60B, 60-J4, 606.14, 60(Plus), 60-V, 72, or 72-V. Frameless modules with model identifier JKMxxxPP-DV. Modules with 46mm frames and model identifier KYxxxZZ-AA; where "Y" is D or U; "ZZ" is blank, GX, or Kyocera SX; and "AA" is LPU, LFU, UPU, LPS, LPB, LFB, LFBS, LP82, LP82, 3AC, 3BC, 3FC, 4AC, 48C, 4FC, 4UC, SAC, 58C, SFC, 5UC, 68C, 6FC, BBC, 6MCA, or 6MPA. LG Modules with 35, 40, and 46mm frames and model identifier LOxxxYaZ-bb; where' 1"' is A. E, N. O, S; a" Is 1 or 2, "Z" is C, K, T, or W; and "bb" is A3, A5, B3, G3, G4, or K4. Longi Modules with 40mm frames and model Identifier LR6-YYxxxM; where "YY" can be 60, 72, or 72HV. Mission Solar Modules with 40mm frames and model identifier MSExxxZZaa; where "ZZ' can be MM, SE, SO or SO; and 'as" can be 1J, 4J, 4S, 5K, 5T, 6J, 6S, or 6W. MODULE COMPATIBILITY r Modules with 46mm frames and model identifier PV-MYY=tZZ; where "YY" is LE or JE; and Mitsubishi IiseitherHD, HD2, or_F_B. mat _ € IM and XS series modules with 40, 45, or 50mm frames.T Neo Solar Power { Modules with 35mm frames and model identifier D6YxxxZZaa; where "Y" can be M or P; "22" can ((( a 83A, 84A, E3A, E4A, H3A, H4A; and "as!' can be blank, (TF), ME or ME (TF). Panasonic Modules with 35or 40mm frames and model identifier VBHNxXXYYzz; where "YY" is SA or KA; and zz" is 01, 02, 03, 04, O6, 06B, 11, 118, 15, 158, 16, 16B, 17, or 18.- Modules with 35, 40, or 45mm frames and model identifier PSxxxY--ZZ/A; where "Y'Is M or P; -Zr i Phono SolarIis20or24; and 'A' is F. T or U. Prism Solar Frameless modules with model identifier BiYY-xxxBSTC; where "YY" is 48 or 60. Modules with 30, 38 and 45mm frames and model identifier RECxxxYYZZ; where "YY" is M, PE, REC SolarTP, or TP2S; and "ZZ" is blank, BLK, SLV, or 72. Renesola Modules with 35, 40 or 50mm frames and model identifier JCxxxY--ZZ; where "Y" is F, M or S; and ZZ" is Ab, Ab-b, Abh, Abh-b, Abv, Abv-b, Bb, Bb-b, Bbh, Bbh-b, Bbv, Bbv-b, Db, or Db-b. i Renogy Modules with 40 or 50mm frames and model identifier RNG-)=Y; where'Y' is D or P. 3 S-Energy Modules with 40mm frames and model identifier SN)=Y--ZZ; where 'Y" is M or P; and "ZZ" is 10, or + 15. Seraphim Energy Group Modules with 40mm frames and model identifier SEG-6YY-x&27_- where "YY" can be MA, MB, PA, PB; and " ZZ" can be BB. WB, or WW. Modules with 40 and 50mm frames and model identifier SRP-xxx-6YY; where "YY' can be MA, MB, Seraphim USAPA, PB, OA•XX-XX, and OB-XX-XX. , Sharp -_ I Modules with 35 or 40mm frames and model identifier NUYYxxx; where 'YY" is SA or SC. Silfab Modules with 38mm frames and model identifier SYY-Z-xxx; where "YY" is SA or LA; SGor LG; and i 2"isM, P,orX. j Solaria Modules with 40mm frames and model identifier PowarXT)=Y ZZ; where'Y' can be R or C; and 1 ZZ" is BX, BY, PX, PZ, WX or WZ. j SolarTech Modules with 42mm frames and model identifierSTU-xxxYY; where "YY" can be PERC or HJT. j SolarWorld Sunmodule Plus, Protect, XL, Bisun, Bisun XL, may be followed by mono, poly or duo and/or black { or bk; modules with 31, 33 or 46mm frames and model identifier SW-xxx. I Stlon Thin film modules with 35mm frames and model identifier STO-xxx or STO-xxxA. Thin film frameless modules with model identifier STL-xxx or STL-xxxA. Modules with 35, 40, or 50mm frames and model identifier SE-Y=cZABCDE; where' Y" is B, F, H. SunEdison P. R, or Z; "Z' is 0 or 4; "A" Is B. C, D. E, H, I, J, K. L, M, or N;'B" is B or W; "C" is A orC; "D" is 3, 7, 8, or 9; and "E" is 0, 1 or 2. Moduleswith 35, 38, 40, 46, or 50mm frames and model identifiers OPTxxx-AA-B-YYY-Z Suniva or MVXxxx-AA-B-YYY-Z; where "AA" is either 60 or 72; *B" is either 4 or 5; "YYY" is either 100,101, 700,1SO, or 1131; and "Z" Is blank or B. Modules with model identifier Ab-xxx-YY and standard (G3) or InvisiMount (G5) 46mm frame; Sunpower where " A" is either E, P or X; "b' can be 17, 18, 19. 20, 21, or 22; and'YY' can be blank, NE, BLK, COM, GAC, D-AC, BLK-GAC, or BLK-D-AC. Sunpreme Frameless modules with model identifier GXB-xxxYY; where "VY" is Wank or SL. Suntech .._.. Vd, Vem, Wdb, Wde, and Wit series modules with 35, 40, or 50mm frames. Modules with 35, 40 or 46mm frames and model identifier TSM-xxxYYZZ; where "YY' is PA05, ` PC05, PDO5, PA14, PC114, PD14, PE14, or DD05; and "ZZ" is blank, A, A.05, A.08, A.10, A.18, .05, I Trina 08, . 10, .18, .OBD, .18D, 0.82, A.082(I), .002, .00S, 05S, 085, A(li), A.OB(il), A.O5(ll), A.10(II), or A.18( 11). Frameless modules with model identifier TSM-xxxYY; and 'YY" is either PEGS, PEG5.07, PEG14, DEGS( fl), DEG5.07(II), or DEG14(11). Winaico Modules with 35 or 40mm frames and model identifier Wsy-xxxz6; where "y" is either P or T; and Y"is either M or P. Yingli Panda, YGE, and YGE-U series modules with 35, 40, or 50 mm frames. L-Mount I QMLM / QMLM2 Elevated Water Seal Technology- 5 ITEM DESCRIPTION 01Y. EDGE TOWARDS ROOF RIDGE NO. I FLASHING. ROUNDED CORNERS. VX IT' X .04(r, SOS2, MILL I 2 L-FOOT, 2' X 3.301' FOR .438.O.D. FASTENER. 6061-16/600SA461. Mitt I 3 WASHER, SEALING. 5/16" ID X 3/4' OD. EPDM BONDED SS I 4 LAG SCREW. HEX HEAD. 5116" x 4", 18-6 SS I L-FOOT 2' X 3.3012 X .7S SLOT FOR .438" O.D. FASTENER, 6061- 1T640DSA-T61 MILL 12 QMLM2: S 2 X .7S' SLOT VERSION 7— I ' OPTIONAL T 14.2a:) E v 0 8 2 4 1___ F T-T 3-30 575 — U _. T AVAILABLEILL BLACK FINISHES TITLE, lC QMILM2 QMLM: L-MOUNT, 5/16" LAG, 9" X IT FLASHING iiitss orr:xw5e s-i.:mo SIZE MA" BY' RXD REVu.eeus.rrr,.+c s as a A ogre 6mmi7 5 m,w.n. on.orc...e.A.n ++roe.ceaF.,.. .r...........____..__._...__.._..._.___. n/LErA:Jvu :M, SGIE Iv wYGrR:1.0>» iseFl?. 3 2 wick Mount PV, RESPECT THE ROOF L-Mount Installation Instructions Installation Toots Required: tape measure, roofing bar, chalk line, stud finder, caulking gun, sealant compatible with roofing materials, drill with 7/32" bit, drill or impact gun with 1/2" socket. Locate, choose, and mark centers of rafters to be :arefully liftcomposition roof shingle with roofing insert flashing between 1st and 2nd course. Slide mounted. Select the courses of shingles where bar, just above placement of mount. Remove up so tap edge of fashing is at least 3/4" higher mountswill beplaced. nails as required and backfill holes with aproved than the butt -edge of the 3rd course and lower sealant. See "Proper Flashing Placement" on next Bashing edge isabove the butt -edge of 1st course. page. Mark center fordritting. Using drill with 7/32" bit, drill pilot hole into roof Clean off any sawdust, and fill hole with sealant Place L-foot onto elevated Bute and rotate L-footto and raker, taking care to drill square to the roof, compatible with roofing materials. desiredorientation. Do not use mount asa drill guide. Drill a 2" deep hole Into rafter. Prepare lag bolt with sealing washer. Using a 1/2 you are now ready for the rack of your choice. inch socket on an impact gun, drive prepared lag Follow all the directions of the rack manufacturer boltthrough L-foot untilL-footcan nolonger easily as well as themodule manufacturer. NOTE: Make rotate. DO NOT over -torque. sure top ofL-Foot makes solid contact with racking. 8172.3-44 Jun-2017 Rev 2 BI 7.2.3-44 Jun-2017 Rev 2 PURE ENERGY GROUP, LLC 407.955A543 THIS into CRC 1331820 SERVICE AND INSTALLATION AGREEMENT 5323 Millenia Lakes Blvd. Suite 300 Orlando, FL 32839 day of a 20 by and between Pure Energy Group LLC ('PE') and f c (hereinafter; _ 'Owner']_ for work to be completed street address) ! (city, state, zip) TERMS AND CONDITIONS: 1. SCOPE OF WORK: PE agrees to supply all necessary supervision, labor, and materials required.to complete the following scope of work Panels: ) Quantity ( lln wA+ a C e ) Brand and Model Inverters: () Quantity ( C A E,19 er ) Brand and Model Roof Modifications: ( } Service Entrance Modifications: Main Breaker Derate Service panel change ( ) 2. ADDITIONAL DETAILS OF CONTRACT: 3. SUBCONTRACT PRICEw]p' I PAY 1E T,/ PE frees to pe orm the Work described above for the sumof WC.tf ic. //6 a c/G/lc+rt rllf/e+Y[ldf/arrfSa/94 )(the 'Contract Price").The payment schedule is deft ed in hibit "B'. If the utility company rebate is as igned by Owner to PE,.then<the utility rebate will be deducted from the contract price. PE has no control over changes to applicable state or federal tax credits, and thus, PE is not responsible/liable for any such changes. PE, at its discretion, may provide Owner with a Preliminary 20-Day Lien Notice to secure PE's right to payment. 4. TIME: PE.estimales that the Work may be completed within %Q dayslweekslmonths;from the date: project,permit(s) are fully, issued by the applicable authority. This is a good,faith; non-bintJmg est m— tf a Gme shall be extended in the"eVent the Work is impacted by weather, acts ofodG, stokes, matenal shortages delivery delays or delays m obtammg permits'ordelays due to unforeseen events or conditions as descnbed in_Sections 7, 8 and•9 of this Contract 5. WARRANTIES, DISCLAIMERS}AND GUARANTEESPE expes`sly warrants'mmor system components for a penod oftwo (2) yearsanp major system components fora period of two `(2) years,or as designated by the. product manufacturer. Trior'to commencement of the Work, PE shall designate in the final construction drawings the areas] where the Work shall be; performed; including the areas] over which PE andlor its subcontractors must ingress and egress to access the area[s] where the Work will be'performed. Owner waives any claims arising out of roof defects or leaks located outside this designated area. Owner waives any claims against PE arising out of pre-existing roof defects or leaks. All warranties shall be voided if Owner or a third party modifies PE's work or the products installed by PE in any manner. Owner is solely responsible for securing the system, products, or other materials from theft or damage prior to completion. Owner is solely responsible for ensuring compliance with any applicable restrictions or requirements of their HOA, and any fines that may be imposed. Owner is advised to notify their insurance company immediately upon execution of this Contract of the solar system being installed and secure insurance coverage for the system. PE guarantees that the Work, when completed, will pass inspection by the applicable state agency or body. PE makes no guarantee of a specific tax benefit to Owner in connection with the installation of the solar system, and PE recommends that Owner hire a licensed accountant or tax attomey to determine the tax implications of the installation. PE makes no guarantees regarding the processing of any rebates in connection with the installation of the solar system. This warranty may transferred or assigned to a third. party at PE discretion. Owner may transfer this warranty to a new owner within 60 days of a transfer of ownership as long as the new owner pays for a system inspection to verify the system has not been modified and is still in working order. ACCORDING TO FLORIDA'S CONSTRUCTION LIEN LAW (SECTIONS 713.001.713.37, FLORIDA STATUTES), THOSE WHO WORK ON YOUR PROPERTY OR PROVIDE MATERIALS AND SERVICES AND ARE NOT PAID IN FULL HAVE A RIGHT TO ENFORCE THEIR CLAIM FOR PAYMENT AGAINST YOUR PROPERTY. THIS CLAIM IS KNOWN AS A CONSTRUCTION LIEN. IF YOUR CONTRACTOR OR A SUBCONTRACTOR FAILS TO PAY SUBCONTRACTORS, SUB -SUBCONTRACTORS, OR MATERIAL SUPPLIERS,THOSE PEOPLE WHO ARE OWED MONEY MAY LOOK TO YOUR PROPERTY FOR PAYMENT, EVEN IF YOU HAVE ALREADY PAID YOUR CONTRACTOR IN FULL. IF YOU FAIL TO PAY YOUR CONTRACTOR, YOUR CONTRACTOR MAY ALSO HAVE A LIEN ON YOUR PROPERTY. THIS MEANS IF A LIEN IS FILED YOUR PROPERTY COULD BE SOLD AGAINST YOUR WILL TO PAY FOR LABOR, MATERIALS, OR OTHER SERVICES THAT YOUR CONTRACTOR OR A SUBCONTRACTOR MAY. HAVE FAILED TO PAY. TO PROTECT YOURSELF, YOU SHOULD STIPULATE IN THIS CONTRACT THAT BEFORE ANY PAYMENT IS MADE, YOUR CONTRACTOR IS REQUIRED TO PROVIDE YOU WITH A'WRITTEN RELEASE OF LIEN FROM ANY PERSON OR COMPANY THAT HAS PROVIDED TO YOU A " NOTICE TO OWNER." FLORIDA'S CONSTRUCTION LIEN LAW IS COMPLEX, AND IT IS RECOMMENDED THAT YOU CONSULT AN ATTORNEY 57- 2 d/f— Owner' s Sign a Date ANY CLAIMS FOR CONSTRUCTION DEFECTS ARE SUBJECT TO T1IE NOTICE AND CURE PROVISIONS OF CHAPTER 558, FLORIDA STATUTES. 1967893. 0 iScanned by CamScanner 6. CONTRACT DOCUMENTS, The Contract documents shall consist of. this Contract,:all exhibits attached hereto; the final construction drawings and specifications end,any other documents which are specifically incorporated herein by reference (hereinafter collectively referred to as the "Contract Documents"). The terms of this Contract shall control in the event of any in or conflicts with other Contract Documents. This Contract and the exhibits attached hereto contain the entire; agreement of the parties with respect to the subject matter of this Contract, and supersede all prior negotiations, agreements and understandings with respect thereto. This Contract may only be amended by a written document duly executed by all parties. 7. PRICING AND PRODUCTS: The Contract Price is based upon construction material prices as of the execution of this Contract. Any significant price increases in construction material that occurs during the period of time between contract execution and substantial completion of the Work, shall cause the Contract Price to be equitably adjusted by an amount reasonably necessary to cover any increase. PE also reserves the right to make adjustments to the Contract.Price due to errors, product discontinuation or typographical errors in advertisements. Any change to the Contract Price or the products installed by PE must be agreed upon in writing by both Owner and PE prior to commencement of the Work. 8. DIFFERING SITE CONDITIONS. If conditions at the job site are (1) conditions which are materially different from the conditions identified in the Contract Documents, or (2) unusual or unknown conditions that are materially different than conditions typically encountered in the work provided for in the Contract Documents; PE shall immediately cease working and notify Owner of said condition. PE shall not be required to Perform any further work unless and until the Parties reach a mutual written agreement with respect to the unknown condition and any changes in the contract price resulting therefrom. 9. WAIVER OF CONSEQUENTIAL DAMAGES. Owner waives claims against PE for any and all consequential damages arising out of or relating to this Contract, including but not limited to, damages incurred by Owner for loss of use, rental expenses related to the Project, loss of profit or revenue, financing, business and reputation, and for loss of management or employee productivity or of the service of such persons. 10. LIMITATION OF LIABILITY. Owner hereby agrees that, to the fullest extent permitted by law, PE's total liability to Owner for any and all injuries, claims, -losses, expenses ordamages whatsoever arising out ofor in any way related tothe project or this Contract from any cause or causes including but not'limited to PE's negligence, errors;'omissions,_strict liability, breach of contract or breach of warrantyshall not exceed the total fees actually paid by Owner to PE for services rendered by PE in connection with this Contract. 11. DISPUTE RESOLUTION: All claims of Owner relating to the interpretation of the Contract Documents, the performance of PE under the Contract Documents, any changes in scope, or payment of the Contract Price shall be referred promptly in writing to PE :via certified mail at the address above, or such other address as PE may designate. Such written notice shall include a detailed description of Owner's claim[s). PE shall then have seven(7) days:from its receipt ofthe written notice•to begin to cure any alleged deficiencies. In the event that Contractor is. unable to resolve Owners claim[s) after being given the notice and an opportunity,to cure outlined herein,'or'jf any other dispute arises between the parties, the parties shall submit the dispute to`a mutually agreed -upon mediator. If, the parliesrare unable to resolve the claim[s]. through mediation, the dispute shall be resolved by litigation in"a court of competent jurisdiction in the State of Florida unless the parties t mutually agree to binding arbitration, in which event ,smh.arbitration shall be conducted by,a private arbitrator pursuant to the Construction , Industry, Arbitration Runes of the American Arbjtration Association unless otherwise ageed upon by the parties Anyiaward.reidered by they` arbitratorshall be final, and judgment maybe entered inaccordance with applicable law in ahy court having jurisdiction thereof: 12. ATTORNEY FEES: In the event it becomes necessary for either Contractor or Owner to employ legal counsel or to bring action at law, arbitration or other proceeding to enforce any of. the terms of this Agreement, the prevailing party in any such action or proceeding shall beentitledtorecoveritscostsandexPensesincurred, including its reasonable attorneys' fees, from the other party. 13. RIGHT TO RESCIND: You may cancel this agreement without any penalty or obligation within three business days of the dated agreement. Cancellation afterthe three days ofcontract execution, but prior to commencement of installation, will result in billing of the actual costs incurred upthe'date Pure Energy Group LLC receives notice ofthe cancellation. 14. TERMINATION: If you cancel this agreement after the three business day right of rescission, Contractor may charge a cancelation fee equal to 25% of the Contract Price or the value of the labor and/or materials provided, whichever is greater. 15. UTILITY RATES AND RATE STRUCTURES: Utility rates and utility rate structures are subject to change. These changes cannot be accurately predicted. Projected savings from your distributed energy generation system are therefore subject to change. Tax incentives are subject to change or terminate by executive, legislative, or regulatory action. _ Owner's Initials I understand that in order to receive my federal and state tax credits, I must have an equal or greater amount of tax liability. Owner's Initials Owner's Signature Signature for Pure Energy Group, LLC Printed Name Printed Name and Title r 867893-vr Scanned by CamScanner J Rpii_ REQUIRED P4SPECTION SEQUENCE f4c' - -2 — --ft A AA g Tlh Max intbtNd. 1P.- Inspection Descri2flon. Footer / Setback Stemwall Foundation / Form Board-SurveySlabMonoSlab, Pre our Lintel / Tie; Beam / Fill Down Cell Sheathing —Walls, Sheathing— Roof Roof Dry In Frame Insulation. Rough In Firewall Screw Pattern Drywall / Sheetrock Lath Inspection kzm Final Solar Final Roof Final Stucco / Siding insulation Final Final Utility Building Final Door Final Window - Final Screen.Room Final. Pool Screen Enclosure Mobile Home Building- Final. D— Pre: Demo Final. Demo Final Single Family Residencew Final Building. (Other) 777, Max: Ins2ection. Descri2flon Electric, Under -ground Footer / Slab Steel Bond Electric Rough T.U.G. Pre -Power Final C>M) Electric Final min Max, MINE Inspecdon Descri2flon Plumbing Underground Plumbing Sewer Plumbing Tub, Set Plumbing Final b Max-. M _101_ 11_ 111 -7 Inns sullen Descid2flon Mechanical Rough Mechanical. Final, NJft"'Offism— Ma L-s-op, r4 11111. W. 1-51 Min max Gas Underground Gas- Rough Gas Final REVISED: June 2014 LIMITED POWER OF ATTORNEY Altamonte Springs, Casselberry, Lake Mary, Longwood, Sanford, Seminole County, Winter Springs Date: -4 •aL4, N f, I hereby name and appoint: gX\;m}c^ an agent of- 'gam..,, .Ac-e o, RCa.ee.4- ne.S NMe of Company) to be my lawful attorney -in -fact to act for me to apply for, receipt for, sign for and do all things necessary to this appointment for (check only one option): The specific permit and application for work located at: Street Address) Expiration Date for This Limited Power of Attorney: 7 e - 9 License Holder Name: 0+4 o Co fipt l0 State License Number: F-C1300Lt t33 Signature of License Holder: Cv6W CRrt be4 - STATE OF FLORIDA COUNTY OF P'% The foregoing instrument was acknowledged before me this day of V'.4 , 20V 1 L , by ()ti-o C ,hQco who is personally known to me or o who has produced 04- as identification and who did (did not) take an oath. Signatur Notary Sea]) S+Who-t t (SA-C ws Print or type name Notary Public - State of re. Commission No. jFM%Tor-4 My Commission Expires: L4- c STEPHANIE STEPHENS Rev. 08.12) Nly COMMISSION # FF213087YF':'vCoeAf` EXPIRES April 07, 2019 u: , _ay;;_p , f ronaatvo;arySe vice.cOrr THIS INSTRUMENT PREPARED BY: Name: STEPHANIE COFFEY Address: 2512 BAY FIELD CT HOLIDAY FL 34691 Permit Number: 18 00002897 Parcel ID Number: 10-20-30-511-0000-0980 The undersigned hereby gives notice that improvement will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement. 1. DESCRIPTION OF PROPERTY: (Legal description of the property and street address if available) I OT QA STGRI ING WOODS PR Rd EGS 93 THRI 1 9..9 JUZ PIXIE ISI P DR S-AbIPnRD PI 32773 2. GENERAL DESCRIPTION OF IMPROVEMENT: SOLAR 3. OWNER INFORMATION OR LESSEE INFORMATION IF THE LESSEE CONTRACTED FOR THE IMPROVEMENT: Name and address: ARTHUR, JOSEPH. 107 PINE ISLE DR SANFORD, FL 32773 Interest in property: 100% Fee Simple Title Holder (if other than owner listed above) Name: 4. CONTRACTOR: Name: OTTO CURBELO- BLUE SKY SOLAR ENERGY Address: 13747 65TH ST, LARGO, FL 33771 6. SURETY (If applicable, a copy of the payment bond is attached): Nam Address: 6. LENDER: Address: Phone Number: 727.648.4913 Phone Number: Amount of Bond: 7. Persons within the State of Florida Designated by Owner upon whom notice or other documents maybe served as provided by Section 713.13(1)(a)7., Florida Statutes. Name: Phone Number: 8. In addition, Owner designates of to receive a copy ofthe Lienor's Notice as provided in Section 713.13(1)(b), Florida Statutes. Phone number: 9. Expiration Date of Notice of Commencement (The expiration is 1 year from date of recording unless a different date is specified) WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART I, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. r1oae,E/JOSEPH ARTHUR Signature of Own ror Lessee, or Owner'sor Lessee's (Print Name and Provide Signatorys Title/Office) Authorized Officer/oirectortPanner/Manager) State of FLORIDA County of SEMINOLE The foregoing instrument was acknowledged before me this 20 day of JULY , 2018 by JOSEPH ARTHUR Who is personally known to me O OR Name of person making statement who has produced identification X type of identification produced: DL pig ' • STEPHANIE STEPHENS MY COMMISSION # FF218087 ary Signature EXPIRES April 07, 2019 t en'sgt=-0' OY GRANT MALOY, CLERK OF CIRCUIT COURT SEMINOLE COUNTY FL CLERK'S # 2018085711 BK 9179 Pg 1997; (1pg) E-RECORDED 07/24/2018 03:20:40 PM 10.00 THIS -INSTRUMENT PREPARED BY: Name: STEPHANIE COFFEY Address: 2512 BAY FIELD CT HOLIDAY FL 34691 NOTICE OF COMMENCEMENT Permit Number: 18 00002897 Parcel ID Number: 10-20-30-511-0000-0980 The undersigned hereby gives notice that improvement will be made to certain real properly, and in accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement. 1. DESCRIPTION OF PROPERTY: (Legal description of the property and street address if available) I OT qR STERI Inlf, WOODS PR 54 EGS 93 THRI 195 m piniF ict is nR cnn(FnRD Ei 32773 2. GENERAL DESCRIPTION OF IMPROVEMENT: SOLAR 3. OWNER INFORMATION OR LESSEE INFORMATION IF THE LESSEE CONTRACTED FOR THE IMPROVEMENT: Name and address: ARTHUR, JOSEPH. 107 PINE ISLE DR SANFORD, FL 32773 Interest in property: 100% Fee Simple Title Holder (if other than owner listed above) Name: 4. CONTRACTOR: Name: OTTO CURBELO- BLUE SKY SOLAR ENERGY Address: 13747 65TH ST, LARGO, FL 33771 6. SURETY (If applicable, a copy of the payment bond is attached): Narr 6. LENDER: Address: Phone Number. 727.648.4913 Phone Number: Amount of Bond: 7. Persons within the State of Florida Designated by Owner upon whom notice or other documents may be served as provided by Section 713.13(1)(a)7., Florida Statutes. Name: Phone Number: Address: 8. In addition, Owner designates of to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b), Florida Statutes. Phone number. 9. Expiration Date of Notice of Commencement (The a)piration is 1 year from date of recording unless a different date is specified) WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST, INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. r"Set/ AW.L JOSEPH ARTHUR Signature of Own ror Lessee, or Owner's or Lessee's (Print Name and ProvideSignatory's Title/Office) Authorized Officer/Director/Partner/Manager) State of FLORIDA Countyof SEMINOLE The foregoing Instrument was acknowledged before me this 20 day of JULY 2018 by JOSEPH ARTHUR Who is personally known to me OR Name ofperson making statement who has produced identification Kl type of identification produced: DL R STEPHANIE STEPHENS MY COMMISSION # FF218087 a y Signature EXPIRES April 07, 2019 7,?!;;t• • tlondaNda'YServke.cofrirerr3SiC-0' D'S GRANT MALOY, CLERK OF CIRCUIT COURT SEMINOLE COUNTY FIL CLERK'S # 2018085711 BK 9179 Fig 1997; (1pg) E-RECORDED 07/24/2018 03:20:40 PM 10.00 I