Loading...
127 Pine Isle Dr - BR18-002896 - SOLARa Building & Fire Prevention Division 8 2018 PERMIT APPLICATION Application No: a 9 U Documented Construction Value: $ y""" a I t Ili Job Address: 127 PINE ISLE DR, SANFORD Historic District: Yes No Parcel ID: 10-20-30-511-0000-0880 Residential Commercial Type of Work: New Addition Alteration Repair Demo Change of Use Move Description of Work: INSTALL ROOF MOUNTED SOLAR PV SYSTEM. 5AKW Plan Review Contact Person: CC) Ce.A Title: Phone: _:- '5 3Col Fax: Email:bc..pcjo e-Ci-Sow+' OnS cn_ GwMOwI. CVl Property Owner Information Name CLEMENTE, FRANK & KAREN Phone: 407.732.4682 Street: 127 PINE ISLE DR Resident of property? City, State Zip: SANFORD, FL 32773 Contractor Information Name OTTO CURBELO- BLUE SKY SOLAR ENERGY Phone: 727.648.4913 YES Street. 13747 65TH ST. Fax: N/A City, State Zip: LARGO, FL 33771 State License No.: EC13004873 Architect/Engineer Information Name: Phone: Street: City, St, Zip: Bonding Company: Address: Fax: E-mail: Mortgage Lender: Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. FBC 105.3 Shall be inscribed with the date of application and the code in effect as ofthat date: 6'" Edition (201 7) Florida Building Code Revised: January I, 2018 Pennit Application NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that 1 will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal. The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value, credit will be applied to your permit fees when the permit is issued. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Co- a . Signa f Owner/A Date Kc,r-e,n Print Owner/Agent'sName Signature of otary-State of Florida Datc ifs% STEPHANIE STEPHENS MY COMMISSION # FF218087 AEXPIRES April 07. 2019ifij`•Q'9: tonnaw"O•ySOryiceMr Owner/Agent is Personally own o e or Produced ID Type of ID DL Sigaturc ofConlraclor/Agent Datc 04-+o 6i r be t o Print Contractor/Agent's Name 4-4 m Signature of Florida Date 4•:MHENS ro.t 218087 April u, avt:•C e7ContracorLowntoMeor Produced ID V Type ofID DL BELOW IS FOR OFFICE USE ONLY Permits Required: Building Electrical Mechanical Plumbing Gas[] Roof Construction Type: Occupancy Use: Flood Zone: Total Sq Ft of Bldg: Min. Occupancy Load: # of Stories: New Construction: Electric - # of Amps, Fire Sprinkler Permit: Yes No APPROVALS: ZONING: ENGINEERING: COMMENTS: of Heads UTILITIES: FIRE: Plumbing - # of Fixtures Fire Alarm Permit: Yes No WASTE WATER: BUILDING: SF 3. n-% Revised: January 1, 2018 Permit Application LIMITED POWER OF ATTORNEY Altamonte Springs, Casselberry, Lake Mary, Longwood, Sanford, Seminole County, Winter Springs Date: cn• "- 1-4-- I hereby name and appoint: an agent of.- _ r .a o6d Name of pa y) to be my lawful attorney -in -fact to act for me to apply for, receipt for, sign for and do all things necessary to this appointment for (check only one option): I O The specific permit and application for work located at: i a-+ Street Address) Expiration Date for This Limited Power of Attorney: License Holder Name: C 4A-8 C,t f bfln State License Number: Ec i300 z4 f 7-3 Signature of License Holder: Gwr rk rju STATE OF FLORIDA COUNTY OF r` The foregoing instrument was acknowledged before me this aCOday of;lur. , 20A I E , by (\+-ro 0 ., e- be 10 who is o personally known to me or o who has produced (J L. as identification and who did (did not) take an oath. Notary Seal) Print or type name Rev. 08.12) Notary Public - State of t='L Commission No. Fe;kttf 0 P 7- My Commission Expires: c4q'lol STEPHANIE STEPHENS MY COMMISSION 9 FF218087 d EXPIRES April 07.2019 PHOTOVOLTAIC MODULE GENERAL NOTES: PTCORD Co) 1. APPLICABLE CODE: 2017 FLORIDA BUILDING CODE 6th ED. & ASCE 7.10 MINIMUM DESIGN LOADS FOR BUILDING AND OTHER STRUCTURES. 2. BOLT DIAMETER AND EMBEDMENT LENGTHS ARE DESIGNED PER NDS(2012) REQUIREMENTS. ALL BOLT CAPACITIES ARE BASED ON A SOUTHERN YELLOW PINE (SYP) WOOD ROOF TRUSS AS EMBEDMENT MATERIAL 3. ALL WIND DESIGN CRITERIA AND PARAMETERS ARE FOR HIP AND GABLE RESIENTIAL ROOFS, CONSIDERING FROM A 7* TO A MAXIMUM 27° (2/12 TO A MAXIMUM 6/12 PITCH) ROOF IN SCHEDULE. ALL RESIDENTIAL ROOFS SHALL NOT EXCEED 30'-0" MEAN ROOF HEIGHT. 4. ROOF SEALANTS SHAH CONFORM TO ASTM C920 AND ASTM 6511. 5. THIS SHEET REFLECTS STRUCTURAL CONNECTIONS ONLY. REFER TO MANUFACTURER MANUAL FOR ALL ARCHITECTURAL, MECHANICAL, ELECTRICAL, AND SOLAR SPECS. 6. ALL ALUMINUM COMPONENTS SHALL BE ANODIZED ALUMINUM 6105-T5 UNLESS OTHERWISE NOTED. 7. LAG BOLTS SHALL BE ASTM A276 STAINLESS STEEL UNLESS OTHERWISE NOTED. B. ALL IRONRIDGE RAILING AND MODULES SHALL BE INSTALLED PER MANUFACTURER INSTRUCTIONS. 9. I CERTIFY THAT THE INSTALLATION OF THE MODULES IS IN COMPLIANCE WITH FBC:BUILDING CHAPTER 16 AND FBGRESIDENTIAL CHAPTER 3. BUILDING STRUCTURE WILL SAFELY ACCOMMODATE CALCULATED WIND LATERAL AND UPLIFT FORCES, AND EQUIPMENT DEAD LOADS. ULTIMATE WIND SPEED VL*(MPH) WIND EXPOSURE B MAX SPAN, MAX CANTILEVER WIND EXPOSURE C MAX SPAN, MAX CANTILEVER WIND EXPOSURE D MAX SPAN, MAX CANTILEVER EMBED. DEPTH REQ. 110 6'-0" O.C. , V-4" O.C. 6'-0" O.C. , V-4" O.C. 4'-0' O.C., 1'-4" O.C. 3" * 120 6'-0" O.C. , 1'-4" O.C. X-C O.C., V.4" O.C. 4'-0' O.C. , 1'4" O.C. 3" * 130 4'-0" O.C. , VX O.C. 4'-0" O.C., 1'4" O.C. 4'-0" O.C. , V-4" O.C. 3" * 140 X-O" O.C. , l'-4" O.C. 4'-0" O.C., 1'4" O.C. 4'-0" O.C. , 1'4" O.C. 3" * 150 X-0" O.C. , 1'-4" O.C. 4'-0" O.C. , 1'4" O.C. 4'-0" O.C. , 1'4" O.C. 3" * 160 X-0" O.C., 1'-4" O.C. 4'-0" O.C., V-4" O.C. 4'-0" O.C. , V-4" O.C. 3" * 170 4'-0" O.C., 1'-4" O.C. 4'-0" O.C. , 1'-4" O.C. 2'-0" O.C., 9" O.C. 3" SCHEDULE REFLECTS COMPONENTS AND CLADDING (C&C) NOMINAL WIND PRESSURES WITH EXPOSURE "B" - "C" - "D", RISK CATEGORY 11, ENCLOSED BUILDING AND h < 30'41 PER ASCE 7-10 MINIMUM DESIGN LOADS FOR BUILDING AND OTHER STRUCTURES" AND 2017 F.B.C. 6th ED LAG BOLT DEPTH REQUIRED IN WOOD MEMBER EXCLUDES ANY ROOF DECKING THICKNESS. 3RD RAIL IS REQUIRED PER ROW OR COLUMN FOR SPECIFIED WIND SPEED AND EXPOSURE. INSTALLATION OF MODULES SHALL BE LOCATED IN ROOF WIND ZONE 1 AND 2. WIND ZONE 3 REQUIRES SITE SPECIFIC STRUCTURAL ENGINEERS APPROVAL. GABLE END BUILDING 0 ROOF WIND AREA ZONES 0 0 IT M DESCRIPTION OTY, I A FLANGE, HEX HEAD,5/16'-18 1 X 1' U -2 rPAW 8 ZINC 2 POST, 1-1/4. OD X 3-1/4', 16063-T5/6063-T6, MILL 3 WASHER, SEALING, 5/16' ID X 11-1/4' OD EPDM BONDED SS 4 LASHING, REPLACEMENT TILE, ALUMINUM MILL 1 5 COLLAR, COUNTERFLASHIN , 1-1/4' ID EPDM 1 6 WASHER, N / ' ID XVOD, 18-8SSWASHER 17 I8-8 SSLAP 18 SCREW, FETIHEAD,7716`18 X I' UNC-2A 18-8 SS I 8 6 AL ANGLE AVAILABLE IN RACKING COMPONENTS MILL, AND BLACK NOT INCLUDED FINISHES 3 4_ ; — 7 2 1 FLASHFOOT2 & QMOUNT TILE REPALCEMENT DETAIL REVIEWED FOR CODE COMPLIANCE W_ PLANS EXAMINER 7 1-7 -1 5 DATE CONCRETE TILE OR COPMPOSITION SHINGLE ROOF FINISH TYPICAL PHOTOVOLTAIC ARRAY PITCHED ROOF LAYOUT - WIC - SCHEDULE - PLAN C1 SCALE: NONE xS-O SANFoRD 18- 2896 A PERMIT ISSUED SHALL BE CONS LICENSE TO PROCEED WITH THE WC AUTHORITY TO VIOLATE, CANCEL, ASIDE ANY OF THE PROVISIONS OF CODES, NOR SHALL ISSUANCE OF A THE BUILDING OFFICIAL FROM 1 REQUIRING A CORRECTION OF ERF CONSTRUCTION OR VIOLATIONS I S. Y.P. 2X4 LOCATE BETWEEN TRUSSES AND NAIL WITH 2- 16D NAIL PATTERN AT EACH END TO WOOD TRUSS TO BE A AND NOT A' TER OR SEr IWIT PREVENT REAFTER tS IN PLANS. THIS CODE MISSED TRUSS CONNECTION DETAIL SCALE: 1 2'=1'-0" 10- 16x2" ST STL SELF TAPPING 12" ALUMINUM INTERNAL SC EW TYP 4 PLCS PER BEAM SPLICE SPLICE BAR (USE WHEN SPLICE AT MID -SPAN W/ e ( 4) #10-16X2' ST STL SELF TAPPING SCREWS TYP IR NRIDGE XR100 ALUM RAIL TYP. TYPICAL SOLAR RAIL BEAM SPLICE DETAIL 5 SCALE: 1 2"=1'-0" S- 1 CUT OUT OR REMOVE TILE TO INSTALL "ROOF ATTACHMENT. RE -INSTALL, RE - FILL AND RE -SEAL TILES AFFECTED WITH APPROVED ROOF M TERIALS ROOF ATTACHMENTS SHALL BE FASTENED TO ROOF TRUSS TYP 2 PLCS PER MODULE SIDE < 25% OF MODULE LENGTH USE ANTI -SEIZE AND TIGHTEN TO TORQUE PER MANUF. INSTRUCTIONS PHOTOVOLTAIC MODULE TYP, ALUM L-FOOT TYP EACH STANDOFF 8" - 16 HEX CAP ST STL BOLT AND ST STL SERRATED FLANGE NUT TYP. S. Y.P. 2X4 LOCATE BETWEEN TRUSSES AND NAIL WITH 2- 16D NAIL PATTERN AT EACF END TO WOOD TRUSS FLAT OR BARREL ROOF TILES TYP. WOOD WOOD ROOF SHEATHING TRUSS TYP. CONIC TILE CONNECTION DETAIL SCALE: 1 2"=1 '-0" 16 HEX CAP ST STL BOLT AND ST STL SERRATED FLANGE -NUT TYP. PHOTOVOLTAIC MODULE TYP, IRONRIDGE MID OR END CLAMP IRONRIDGE XR100 RAIL QMOUNT TILE REPLACEMENT FLASHING AMOUNT TILE REPLACEMENT ATTACHMENT 2) 16" ST STL LAG BOLT - SEE SCH FOR EMBED DEPTH REQ. END - CLAMP OR MID IRONRIDGE XR100 TYP. COMPOSITION SHINGLE/ METAL ROOF ( DET OMITTED FOR CLARITY) 5" - IRONRIDGE 1) 5" ST STL LAG BOLT - FLASHFOOT2 TYP, WOOD SEE SCH FOR SHEATHING WOOD ROOF EMBED DEPTH TRUSS TYP. REQUIRED COMPOSITI COPYRIGHTED BY CASTILLO ,ENGINEER,ING SERVICES, LLC Castillo Gr engineeringCESIGNED TO Fj*MIT' CASTILLO ENGINEERING SERVICES, LLC COA" 29345 2381 CREST RIDGE COURT SANFORD, Ft 32M R, " 07.47"-918ERMOCUTH E C9T1 LCI- R PE 32590 REVISIONS DESCRIPTION DATE REV PROJECT DEVELOPER JUN 252018 S•Do1w* . Thh S"I PROJECT NAME 0 c/ N 00 0 V oc Lu Z 0 J d Z 0 Vcle a W LE0 0 oc0 a.; LU Q 0 oA aZQSHEETNAME DATA SHEET ESHEET SIZE ANSI B l 1" X 17E' SHEET NUMBER S-01 DIRECTORY OF PAGES PV-1 PROJECT SUMMARY PV-2 SITE PLAN PV-3 SINGLE -LINE DIAGRAM PV4 SAFETY LABELS PV-5 ATTACHMENT PLAN PV-6 ATTACHMENT DETAILS PV4 FIRE SAFETY PLAN MODULE DATASHEET OPTIMIZER DATASHEET X INVERTER DATASHEET 0Z a MOUNTING SYSTEM DATASHEET MOUNTING SYSTEM ENGINEERING LETTER Q UL 1703 CLASS A FIRE CERTIFICATION UL 2703 GROUND AND BONDING CERTIFICATION ANCHOR DATASHEET m Nw-'" y xx- SCOPE OF WORK THIS PROJECT INVOLVES THE INSTALLATION OF SOLAR y,..a- PANELS. THE SOLAR PANELS WILL BE RACKED USING A PREENGINEERED RACKING SYSTEM. THE RACKED MODULESisleD, pine I. WILL BE ELECTRICALLY CONNECTED WITH DC TO ACPOWER INVERTERS AND INTERCONNECTED TO THE LOCAL UTILITY USING MEANS AND METHODS CONSISTENT WITH THE RULES ENFORCED BY THE LOCAL UTILITY AND PERMITTING JURISDICTION. PROJECT DETAILS 1 PLOT PV-1 SCALEATS PROPERTY OWNER 127 PINE ISLE DR. SANFORD, FLPROPERTYADDRESS32773US APN d ZONING RESIDENTIAL USE AND OCCUPANCY ONE- OR TWO-FAMILY DWELLING CLASSIFICATION GROUP (GROUP R3)I€I t' - AHJ UTILITY COMPANY FLORIDA POWER & LIGHT CO rro. - S ddndo -. ELECTRICAL CODE 2014 NEC (NFPA 70) FIRE CODE 2015 NFPA 1- CONTRACTOR INFORMATION COMPANY BLUE SKY SOLAR LICENSE NUMBER {y_ ADDRESS 4628 EAGLE FALLS PL, TAMPA, FL P r 33619 PHONE NUMBERr. CONTRACTOR SIGNATURE 2 LOCALE PV-1 SCALE:NTS THIS DOCUMENT HASBEEN PREPAREDFOR THE PURPOSE OF DESCRIBING THE DESIGN OF A PROPOSED PV SYSTEM WITH ENOUGH DETAIL TO DEMONSTRATE COMPLIANCE WITH APPLICABLE CODES AND REGULATIONS. THE DOCUMENT SHALL NOT BE RELIED UPON AS A SUBSTITUTE FOR FOLLOWING MANUFACTURER INSTALLATION INSTRUCTIONS. THE SYSTEM SHALL COMPLY WITH ALL MANUFACTURERS LISTING AND INSTALLATION INSTRUCTIONS, AS WELL AS ALL APPLICABLE CODES. NOTHING IN THIS DOCUMENT SHALL BE INTERPRETED IN AWAY THAT OVERRIDES THEM. CONTRACTOR IS RESPONSIBLE FOR VERIFICATION OF ALL CONDITIONS, DIMENSIONS, AND DETAILS IN THIS DOCUMENT, SYSTEM DETAILS DESCRIPTION NEW GRID -INTERACTIVE PHOTOVOLTAIC SYSTEM WITH NO BATTERY STORAGE DC RATING OF SYSTEM 5,400W AC RATING OF SYSTEM 5,000W AC OUTPUT CURRENT 21.0A INVERTERS) 1 X SOLAR EDGE SE5000H-US MODULE O.PEAK BLK-G4.1 300 ARRAY WIRING 1) STRING OF 18F(l) INTERCONNECTION DETAILS POINT OF CONNECTION NEW LOAD SIDE AC CONNECTIONPERNECSECTION705.12(D) UTILITYSERVICE 120/240V 10 ELECTRICAL PANEL MAIN SERVICE PANEL W1200A BUSBAR, 200A MAIN BREAKER SITE DETAILS ASHRAE EXTREME LOW 0"C(32-F) ASHRAE2%HIGH 33°C(91°F) CLIMATE DATA SOURCE VERO BEACH MUNICIPAL AIRPORTKVRB) WIND SPEED RISK CATEGORY It WIND EXPOSURE CATEGORY GROUND SNOW LOAD P-90329 m W n co ti Lu W M O J _J n u- d Z w a O U) N Z 0 Q W PROJECT Pv-1 P-90329 N L1J Z,. tO (N) INVERTER (I1), OUTDOOR N) TRANSITION BOX (JBiI,. OUTDOOR, OUTPUT OCI CULT CONDUCTORS SHALL BE RUN IN EMT2CONDUITOVERROOFNOCLOSERTHAN0.5' ABOVE ROOF SURFACE Cn LuLLJ 0 w W M c J J C/ LL W Q Z OC O ILL N ZrQ 3'. (N) PROPOSED ROOF -MOUNTED PHOTOVOLTAIC O3 ARRAY. 8:12 (34°) SLOPED ROOF,18PVMODULES 1 SITE PLAN AERIAL VIEW ( BLACK FRAME), 180°AZIMUTH01 PV-2 SCALE' 1' = 20' SITE PLAN DOC ID: 90329-112270-1 DATE: Brsn8 CREATOR: A.F. REVIEWER: REVISIONS PV-2 GENERAL NOTES EQUIPMENT LIKELY TO BE WORKED UPON WHILE 1 ENERGIZED SHALL BE INSTALLED IN LOCATIONS THATSATISFYMINIMUMWORKINGCLEARANCESPERNEC SECTION 770.26. 2 CONTRACTOR SHALL USE ONLY COMPONENTS LISTED 8Y A NATIONALLY RECOGNIZED TESTING LABORATORY FOR THE INTENDED USE. CONTRACTOR IS RESPONSIBLE FOR FURNISHING ALL 3 EQUIPMENT, CABLES, ADDITIONAL CONDUITS, RACEWAYS, AND OTHER ACCESSORIES NECESSARY FOR A COMPLETE AND OPERATIONAL PV SYSTEM. WHERE DC PV SOURCE OR DC PV OUTPUT CIRCUITS ARE RUN INSIDE THE BUILDING, THEY SHALL BE 4 CONTAINED IN METAL RACEWAYS, TYPE MCMETAL- CLAD CABLE, OR METAL ENCLOSURES FROM THE POINT OF PENETRATION INTO THE BUILDING TO THE FIRST READILY ACCESSIBLE DISCONNECTING MEANS, PER NEC SECTION 690.31(G). 5 ALL EMT CONDUIT FITTINGS SHALL BE LISTED A5 WEATHERPROOF FITTINGS AND INSTALLED TO ENSURE A RAINTIGHT FIT, PER NEC SECTION 358.42. w MootnE MODULESOPTIMIZERREFDTY. NNE ANDY PMAX PTC me 1 EV 1 VOC VMP TEIP.CEFF.OFVOC FUSEMTNG OCELIHOPFAKIILK04.1300 300W RM' VnA BSeA >Bry no I 0.111W'CIO—C) TDA PMT-1B INVERTERS JDOW 1 2 FOTYQQ MAKEANDMODFL AC VOLTAGE GROUND MAX OCPD RATING RATED POWER MAXOUTPUTCUREHT MAX9VUTCLIRREHT MAXNPUTVOLTAGE DECWEIGHTED EFFICIENCY IyKpi n NRSOEOGE SEWW. 1M6VK NOV LNUiOUNOEO 40A 6.WOW 21 CA 13 SA 46O, 990% A IPOWER OPTIM2ERS OCPDS REF. NDOl MATED NfttT POWER NAX d11PUf WRRERi YAJI INPUT I6C MAXOC VOLTAGE i11E0 Fi11Cl REF. I my I MTED cumEn CS, t 3pA MAX VOLTAGE34NA0P01-18 1 ie 1 5(XM EDGE P310 I 333W I tsA 11.M 4e4 M.IN{ SYSTEM SUMMARY NOTES STRING i PUVERS MAX OUTPUT CURRENT TIEOTPVTVOLTAGEOFTHEPOWENOPnMIffAS ARE REGUTATED I THE INVERTER. THEY ARE NOT 86VACIFOAACRONBOX Wk4ZERS INSERIES VOLTAGEINALSYTTE NUMBO OF MOOLYES IN THESTRNG. TIE CNUA)MSCMENT OF ASINGLESTRNG IS aEp1KTOTHEY1100.M OUTPUT CUI ENT OF THE OPTN R JBI Y OPEMTNG CURRENT 14.OARAY STC POWER SAWN THE SOLAR EDGE INVERTER IS EQUIPPED WRH A RAPIDSHUTDOWN FEATURE VABOI CONFORM TO NEC 2 MY PTCPOWER NVER ER A%AC, CURRENT4. BM IL SECTION S90.10.WHN0I REGIMESTRATARANDSNITOOWNFEATUREPOSTSTODE ENFAGUE wSOURCEZIA GRCUOS MOMALL SDURCESTOIESSTNNN 30VOLTSWDHIN 10 SECON06 AACPOUTER 5,600W115, 000W EMTFD ILECI AC POWERTHE SPECPIEDOPTWM CAN BESUSSTITUTEDNTH AP400. P405. MO. OR P505 THESEOPTINC RSNAVE 4.eNW u QS A,CURRENL AN INPUT VOLTAGE WINDOW WIDE ENOUGH TO ACCOMMODATE THE OUTPUT VOLTAGE RANGE OF THE MODULE ATTHEOESILNTEMPURAT1AES, NAVE AMAX INPUT CURREMMTNG TMTISABOVE THE MH OIPUTOIIDAWf THE MODALAAPOKERNPUi1MT BABOVEiNEMTEDPOWEI10UTRli OFTHE NODALQ ONGRCUNDEDS/ S7EM DC CONDUCTOP54ULL BE COLOR.CODED AS FOLLOWS, OC POWK SAL BE RED TOR MARKEDRED) 40 DC NEGATNE SMALL BE SLACK TOR MARKED BLAOO 441SSPAEPNEi NYILN IR 3W 911RYA191ENWI METER AsA TO MAX DC VOLTAGE OFARMY LS FIXED RYTHE INVERTER AT MV REGMCLESS OF TEMPERATURE. THE MAY DC VOLTAGEOFTIEMOWLEATO-CME) PECTFDTOBE425V(D-C 35'C)X4l,IIVMA3B.TSV.4ZSV)) TIESCLAREOEINVERIERIS N ISMATED.KMERTHENEO fT NMPOWI COAUMMIS GROUNDED AV0 THEREFORE NODC GEC IS REQUIRED. QWIEGRATED OC DISCONNECT ISPROVIDED WITH NJFATER OISCOIMCT IS LISTED FOR USE WITH SOLAR EDGE A. 1741L'VED STRINGNVEATEHS. W SYSTEM PONi.OFt,OVNEcnON ISON THE LOAD SIDE OF SERVICE DISCONNECT, OUTPUT IS RIOTED THROUGH WEAKER N MANPANEL THEW WEN{ERSMALLNOTBEM,AREDFOR-LINE' AND70AD'. THE W BREAKER SHALL BE LOCATED ATTHEOPPOSITE ENO OF THE WSW FROM THE MAIN WEMERCONDUCTOR AND CONDUIT SCHEDULE WIELECTRICAL CALCULATIONS TYPICAL CONDUCTOR CONDUITCOWUCTORSN LURPENfi'.NNYNGaPo EGL TEMP CON COHOIR FILL NE CO. MAYCAWNT RASE DERAMO TERM AI&.®TERM. COOLP FACTOR FACTOR CURRENT Tim) ACV. AAP TEBMF. RATING TOP. MATING I 10AWGC VRIKE. AIRWA WA 6 ANS BARE. COPPER 0.T6WC.) 10 15A A5A 56A 41 SA 15•C 56A 3 I 0 AW01H5NL2 COPPE0. 0.S OA EMTT NM 10 AWG TICOPPER 0.76(65'C) 1.0 15A STW 40A MA we 30A 3 1 COPPER2 75'DAEMT SAR 2 0.06 f33'CI 10 21A 2SA 5SA IMSA W-C 4DA COPPE GROUNDING NOTESALL EQUIPMENT SHALL BE PROPERLY GROUNDED PERTHE 1 REQUIREMENTSOFNECARTICLES250 & 690 PV MODULES SHALL BE GROUNDED TO MOUNTING RAILS USING MODULE LUGS OR RACKING INTEGRATED 2 GROUNDING CLAMPS AS ALLOWED BY LOCAL JURISDICTION. ALLOTHER EXPOSED METAL PARTS SHALL BE GROUNDED USING UL-LISTED LAY -IN LUGS. GROUNDING SYSTEM COMPONENTS SHALL BE LISTED FOR 3 THEIR PURPOSE IF THE EXISTING MAIN SERVICE PANEL DOES NOT HAVE A VERIFIABLE GROUNDING ELECTRODE, IT IS THE 4 CONTRACTOR'S RESPONSIBILITY TO INSTALL A SUPPLEMENTAL GROUNDING ELECTRODE. AC SYSTEM GROUNDING ELECTRODE CONDUCTOR (GEC) 5 SHALL BE A MINIMUM SIZE #6AWGWHEN INSULATED, #SAWG IF BARE WIRE. EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED ACCORDING TO NEC ARTICLE 690.45, AND BEA MINIMUM OF 6 #10AWG WHEN NOT EXPOSED TO DAMAGE, AND #6AWG SHALL BE USED WHEN EXPOSED TO DAMAGE GROUNDING AND BONDING CONDUCTORS, IF INSULATED, 7 SHALL BE COLOR CODED GREEN, OR MARKED GREEN IF 4AWG OR LARGER i SINGLE -LINE DIAGRAM PV-3 SCALE: NITS 1W660L6HBlTlN66®1 tlEAlID FM11E NbtlEE OF6F6LRRPN6,TE6EMON OFAPRpggpgpl6lAATA¢P6NFN S/SIFINMIHp101FA16E'NL TO pEY0x6*MT£CppLIWEWIfX µt APPIx:AYE CCOE.S ANU REPAATgvS. TIE WF1xEM LNIXIL NGT6E-U N AflRBrtMEFOR f(ALO/IIAT W.M6ACDRFR 6N6TN1ATd 4M41.LL8FTILLfRNN1x91NiM1E9lNFMx4'COM14AYATNYAAVFACPlERM61NUTgx MVNMLL6Ip11MGN1N966GAEI1t6N01ApWNIBPPETFDxAWAY 11M10V01RIpE6 P.EN61FNCfKQN6x WM1fAC11FE4 NNNJAnONWYJN9 m Lu H cn w UJI C) d O cn in LJLI m w V P- 90329 m cl Lu 1 S2 W z_ f` aN— SINGLE - LINE DIAGRAM PROJECT ID: 90329 DATE 06109118 CREATED BY: AF. CHECKED BY: REVISIONS PU M CV M I L1. 0 Q L. L z Q co DC RACEWAYS O O SEE NOTE NO, 4 (DCRACEWAYS) WARNINGJBt - TRANSITION BOX MODEL NOT SPECIFIED) PHOTOVOLTAIC POWER S( OO NEC SECTION 690.31(G)(3( AND IFC 605.11.1 ODC DISCONNECT (11 RATED MPP CURRENT:13.5A RATED MPP VOLTAGE: 380V MAX SYSTEM VOLTAGE: 480V NEC SECTION690.53 BO SOLAR BREAK=R(MSP) l W AMING I 3E O..Z rt r7 Cb `40i 41 7C Px NEC SECTION705.12(D)(2)(3)(8) OPOINT -OF -INTERCONNECTION OR AT MAIN SERVICE DISCONNECT (MSP) I CAUTMIN I POWER TO THIS BUILDING 15 ALSO FROM ROOF MOiWTED SOLKR ARRAY WITH SAFETY D'SCONNFCTS ASSHOWN SECTION 690 561BI OAC DISCONNECT (CB1 IN MSP) MAXIMUM AC OPERATING CURRENT: 21.OA MAXIMUM AC OPERATING VOLTAGE: 240V NEC SECTION 690.54 OANY AC ELECTRICAL PANEL THAT IS FED BY BOTH THE UTILITY AND THE PHOTOVOLTAIC SYSTEM (MSP) WARNING NEC SECTION 7D5.12(D)(3) O7 SEE NOTE NO.5 (MSP) NEC SECTION 690.56(C) AND IFC 605.11.1 10 ACSOLAR DISCONNECT (C137 INMSP) PHOTOVOLTAIC AC DISCONNECT NEC SECTION 690.13(B) LABELING NOTES 1 ALL PLAQUES AND SIGNAGE REQUIRED BY 2014 NECAND2015NFPA1WILLBEINSTALLEDASREQUIRED. LABELS, WARNINGS AND MARKING SHALL COMPLY WITH ANSI Z535.4, W ICH REQUIRES THAT DANGER WARNING, AND CAUTION SIGNS USED THE STANDARD 2 HEADER COLORS, HEADERTEXT, AND SAFETY ALERTSYMBOLONEACHLABEL. THE ANSI STANDARD REQUIRES A HEADING THAT IS AT LEAST 50%TALLER THAN THE BODY TEXT, IN ACCORDANCE WITH NEC SECTION 110.21(8). A PERMANENT PLAQUE OR DIRECTORY SHALL BE INSTALLED PROVIDING THE LOCATION OF THE SERVICE 3 DISCONNECTING MEANS AND THE PHOTOVOLTAICSYSTEMDISCONNECTINGMEANSIFNOTINTHESAME LOCATION IN ACCORDANCE WITH NEC SECTION 690.56(B). LABEL(S) WITH MARKING, 'WARNING PHOTOVOLTAIC POWER SOURCE,' SHALL BE LOCATED AT EVERY 10 FEET OF EACH DC RACEWAY AND WITHIN ONE FOOT OF 4 EVERY TURN ORBEND AND WITHIN ONEFOOTABOVEANDBELOWALLPENETRATIONSOFROORCEILING ASSEMBLIES, WALLS AND BARRIERS. THE LABEL SHALL HAVE 3l8' TALL LETTERS AND BEREFLECTIVE WITH WHITE TEXT ON A RED BACKGROUND LABELS) WITH MARKING,'PHOTOVOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN; SHALL BE LOCATED 5 AT POINT -OF -INTERCONNECTION OR AT MAIN SERVICEDISCONNECTTHELABELSHALLHAVE3/8' TALL LETTERS AND BE REFLECTIVE WITH WHITE TEXT ON A REDBACKGROUND P-90329 W H cn co C'7 ti W ch J JOU) LLd ZQ O cn C, Q coW H U SAFETY LABELS PV-4 P-90329 I H I I ! s I ) 1 RIDGE I 1 I w N 1 I i I ! I ! EAVE 0 OI C!i cl Lu v) LL_ Z EL Q 1 1 ATTACHMENT PLAN (OBLIQUE PROJECTION) F- PV-5 SCALE 1/8" = 1' p o ATTACHMENT PLAN DOC ID : 90329-112270-1 DATE: 619118 CREATOR: A.F. REVIEWER: REVISIONS PV-5 ROOF PROPERTIES ROOF MATERIAL COMPOSITION SHINGLE (1 LAYER) SLOPE 8112 (33.T) MEAN ROOF HEIGHT 26FT DECK SHEATHING 7lifi' OR THICKER OSB OR PLYWOOD CONSTRUCTION TRUSSES (2X4 TOP -CHORD), 241N OC MODULE MECHANICAL PROPERTIES MODEL Q-CELLS O.PEAK BLK-G4.7 300 DIMENSIONS (AREA) 66.71N X 39.41N X 1.31N (18.0 SO FT) 41.4L8 MOUNTING SYSTEM PROPERTIES MAX. AL10'N. RAIL SPAN 108.DIN (ZONES 1, 2, AND 3) MAX. MOUNT SPACING 48.OIN (ZONES 1, 2, AND 3) MAX. ALLCW. CANTILEVER 43.21N (ZONES 1, 2. AND 3) GROUNDING AND BONDING INTEGRAL GROUNDING CERTIFIED TO UL 2703 REQUIREMENTS NOTES RAFTER LOCATIONS ARE APPROXIMATE. ACTUAL 1 LOCATIONS MAY DIFFER AND CONTRACTOR MAY NEEDTOADJUSTMOUNTLOCATIONS. IN NO CASE SHALL THE MOUNT SPACING EXCEED WAX MOUNT SPACING' P-90329 XRI' RIDGE PV MRAfL UICKMOUNT QMLM COMP, SHINGLE C iROOFING MATERIAL W FLASHING INSTALLED >- RAIL CLAMPING ZONE ' BETWEEN UPPER AND cn ch LOWER COURSE OF Of tiSHINGLES LuLLJ c04 INTO ROOF O N STRUCTURAL MEMBER Lu OfZic ATTACHMENT DETAIL RANSVERSEVIE J O PV 6 SCALE: NTS 0 Ncf) ZMOUNTING NOTES p < FLASHING SHALL BE APPLIED IN ACCORDANCE WCM W AVsFIUFACTURERSPRINTED INSTRUCTIONS. IF THERE6 ANYCONFLICT BETWEEN WHATIS DEPICTED 2 HERE AND INSTRUCTIONS PROVIDED BY THE MANUFACTURER, MANUFACTURERS' INSTRUCTIONS SHALL SUPERCEDE. a RACKING ELEVATION (TRANSVERSEVEN Pv 6 SCALE: NTS PV MODULE IRONRIDGE XRIOG RAIL OUICKMOUNT QMLM COMP SHINGLE ROOFING MATERIAL ATTACHMENT DETAILS DOC ID: 90329-112270-1 DATE: 61 18 RAFTER SPACING )ATTACK'JW SPAN —? LAG SCREW INTO ROOF CREATOR: A.F. STRUCTURAL MEMBER REVIEWER: REVISIONS a RACKING ELEVATION (LONGITUDINALVIEM o ATTACHMENT DETAIL (LONGITUDINAL YKW _ F' V-6 SCALE' NTS P1 SCALE: SCALE PV- 6 FIRE SAFETY P-90329 N. N z. W O a M ti N LLI tM J J LL O ROOF ACCESSPOINT, PER NFPA111.12.2.2.13 O C LLf w p Z fY O N Q 3 02 3.0 FT. WIDE SMOKE -VENTILATION SETBACK PER NFPA J 111.101.2.2.2 PV MODULES INSTALLED ON ROOF WITH IRONRIDGE 1 FIRE SAFETY PLAN ROOF MOUNTING SYSTEM. THE MOUNTING SYSTEM IS O CLASS A FIRE RATED ON A8112 SLOPED ROOF WHEN Ur PV-7 SCALE: 1' = 20' INSTALLED WITH TYPE 1 OR 2 MODULES. THE 0- CELLS O.PEAK BLK-G4.1 3001S TYPE 1. o 1.5 FT. WIDE FIRE ACCESS PATHWAY 5 CABLES, WHEN RUN BETWEEN ARRAYS, SHALL BE ENCLOSED IN CONDUIT. FIRE SAFETY PLAN DOC ID: s032&11227D-1 DATE: 619/18 CREATOR: A.F. REVIEWER: REVISIONS PV-7 REQUIREMENTS EXTERIOR -MOUNTED DC CONDUITS, WIRING SYSTEMS, AND RACEWAYS FOR PHOTOVOLTAIC CIRCUITS SHALL BE LOCATED AS CLOSE AS POSSIBLE TO THE RIDGE, 1 HIP, OR VALLEY, AND FROM THE HIP OR VALLEY ASDIRECTLYASPOSSIBLETOANOUTSIDEWALLTO REDUCE TRIP HAZARDS AND MAXIMIZE VENTILATION OPPORTUNITIES (NFPA 1 11.12.2.2.4.1) ROOF ACCESS POINTS SHA With its top performance and completely black design the new Q.PEAK 9LK-G4. t is the ideal solution for all residential rooftop applications thanks to its innovative cell technology C.ANTUNI. The world -record cell design was developed to achieve the best performance under real condi- tions - even with low radiation intensity and on clear, hot summer days. LOW ELECTRICITY GENERATION COSTS Higher yield per surface area and lower BOS costs thanks to higher power classes and an efficiency rate of up to 18.3 %. A INNOVATIVE ALL-WEATHER TECHNOLOGY FSOptimal yields, whatever the weather with excellent low -light and temperature behavior. ENDURING HIGH PERFORMANCE Long-term yield security with Anti-PID Technology', u Hot -Spot -Protect and Traceable Quality Tra,QTA', opEXTREME WEATHER RATING i QCEUS High-tech aluminum alloy frame, certified for high snow 5400 Pa) and wind loads (4000Pa) regarding fEC. MAXIMUM COST REDUCTIONS Up to 10% lower logistics costs due to higher module capacity per box. - -- O A RELIABLE INVESTMENT,h,,,,T°ere° Inclusive 12-year product warranty and 25-year linear performance guarantee'. In. THE IDEAL SOLUTION FOR: w vm+.n ex Gndd:nge Engineered in Germany APT test condit-s: CeIIS at 1500V against grounded, with c.oduclaveme- tal foil covered module surface, 25'C. 168h See data sheet on rear for further Inr.rma0on. QCELLS MECHANICAL SPECIFICATION Form: t 65 7,n x 394.n . 1.261n (including frame) 0670 min . 1000mm . 32 W.rZId 41. E5'.bs(18.8I1i1- Front Cover 0.13.n (3.2mm) fir-.l.y pre Mooed glass ,V, .nil •ef ect.o technology r. rBachCoverCarnlwsilefilm Frame Oink anodised aluminum • w m r - Cel! 6 . 10 m.n nnitalline Q.ANTUM solarcells Junction boa 2.60 3.031n.4.37-3.54in< 0.59.0.75,n(66-77 min. 111-90r)m. 15-19mm), Protect:.. class IP57, wM b". diodes '• G,lid 4mrn2Sola cable: (.1a3937 to (t(IOOmml. 1-) x39.371n I1000mm) connector U Ib-Conh tU(.. or MCA rlamatea.le IP68 yF , rrrr : 'Turur ELECTRICAL CHARACTERISTICS POWER Dws 230 2fP4 300 MINIMUM PERFORMANCE AT STANDARD TEST CUROITIONS, STC:POWER TOLERANCE +5W14 W; Powa, at MPP' Pr, IWl 290 295 300 Short Cueui( Current. 4 IAl 9.63 9,70 9.77 E Op^-n circmt Yo ,U Ve IV) 39.19 39.48 39.76 --. Cement al MPP. Ira JAI 9.07 9.17 9.26 Von, alMPP • Vmr TV] 31.96 32. 19 3241 Elnc-cy' n l%1 z17.4 ;_;77 MINIMUM PaRFORMANCE A'+' NORMAL OPERAT IN6 CONDITIONS, NOV Pe at MPP' Pr, IWI - - _ 214.4 218.1 221.8 E Shan Cooint Corr."' 1. JAI / 71 _ 702 788 Open Cocoa V.Pure, vx IVl 36.65 36.92 37A9 9 Ciereul.!MPP• I_ JAI 712 720 727 I voltage atMPP' Vep IV) 30.12 19.30 30.49 w:, •.>. ,num..a ,....,, ,-- .,r. 1 a .,x saps uu. r., +Y ... QGEUv RRBfQRMARCE WAP.RAMY - - ^y - AA'AgiJ ¢ l : yi -- _,.'i arnmm.al raw. during tn_tY err •-_r____________ ______,____ ; and ma.fl.GR1 .odor -C Yea. e .... p' a. Y • A sr 92 6 r p , p I lO M.6 ye n E AI [ 93 6'a nopac p t 25 yea'. 1dma. 2n,,, neaw+e,neer taesnca.- rup r0 re, 0 InCELLS Ino pathOre pa:entydre, o egos ads «ganuaDun erraw r 9 r reaxrve:ounny - ,e r -- MaRIEArE1WNn Yraa Typical module parannence undo, I-Pradirs-cundina,sl. conga- to STC conadim, t25'C, I(11Ill rEMPERATUI E GINmCIERTS TemperaW, e n m f 1 . (x/N) r 04 Ta.pe,atu C I tof V. U Ix KI - 0.28 Tempaalur conkciao o. P,-, v IX/NJ Normal Op -no, cell Tampa: o" NOCT I'Fl 113 .5 4 05 z 3 `C) PROPERTIES FOR M4annun, syslesn Voltage V.•n IVI 100001101 'IOCOWL; Safety Cla.so II roamSeries Fir. Raring JA DO 20 nr. Rating r, IEC) i TYPE 1 (.11-; 0esgn load, push IUI), ribrith) 75 i3600Pa; Pomitted module te,nperaI- - 40'F .. to .185`1` An ca,nnucua duty 1-40'C up 11185'CI Oeslgn load, pull IDLY IbdMl 55.6 (2666Pa' see -tall, or manual UALIFICATION51 UL 1703: VAE Qudrly TedW: CE-mmplrant: Numhr 0Modules per P.H. 32 IEC 61215 IEd21: IEC 617M (Ed it appl-Ke. classA Mloop: a Pallets pe, 58 C.ob er 30 Number of Pallets Per 4Q' container 26 VE C EC116Paltel0, or ions IL. W.NI 687in. 45.31n . 46. tin 1745mm x 1150mm x 1170mm1 Pa1lat Weigh 14351. z (651 kg) All nstallatiae 1- rod 1 mud M Wined, See Oro lod0anon antl apart,.. main:.-. cr -.noel pu, --cal serptt ".room, ra °. . Inramatida, on apa..ed andenMm„ and use M Ims ado- Wn, O CELl3 -. I. Yc 300 Spectrum Center Odve, SP4e 1250, Irvine, CA 92618. USA t'I EL.I 9A9748 59 961 ETIAR mnuirYsua,.-xlls.com I WEE wr.9-eellsus solar=es SolarEdge Power Optimizer Module Add -On For North America P320 / P370 / P400 / P405 / P505 supartorefltctericyfig _5%I MiTilptes ailtype, ofmodWe murcaul3 losses, from,manufacturing tpteranceto partial shading Flexible system oesig for rnax murxF sate utlllxaflon Past Installation with a single bolt - - -` Next generation maintenancewith module -level monitoring Compliant with arc fault protection and rapid shutdown NEC requirements (when installed as part of the SolarEdge system) Module -level voltage shutdown for installer and firefighter sa"I USA-CANADkCARMMir+ Jx-iTAU(ME[if WWWSOtaredge.es Wfl.%WWUTH AFRMA-PUTAND-CZCCH REPVM IC solar=ee SolarEdge Power Optimizer Module Add - On for North America P320 ! P370 / P400 / P405 / P505 OF'Ft M(2ENMODEL P320 _ P370 P400 P405. tor highervpywuP503OYPka1 rcrcrhile <: nmPaH6AHY1 tor htahpower _ 6pAnd 72<erl (for 72N 96<.MI (Fa s9iin NrA - iFPrteDeall nxxWsos7 rt,aa„„c modul.rp ixdulest wr,.ra euAviesl W1e0,tna, OC Pmner'u 320 370 490 an 505 w Absolute Mankrnmt input vr*'Wr 725 83 Vdc YbC atbwe3tItmperitum) M?P?.° per>dRBw"d R-as 8.60 a eo 12-S 1D5 its 93 L wx Mid11NJIR Sheri tlTxull CwfeM (IX( 11 1 10.1i 14 4dc Madman OC Mput OxreM13 .75 .. 3. ,. .__ .... 3.2.63MiernRAn wMghhd Elnde.. q . 98.8 46 OrervoRage Cate or rl f..TPIR OUR NG OPERATION (POWER OPTIM17f.R CONNECTED TO OPFRAT`.N6'.rOLARFOGF}NVEIETERj'" 95 V OUTPUT DURING STAN09Y(POWEROPT{MUER OISCONWCTED FROMSOLAREDGE INVERTER. ORSOIARCDGE. INVERTEROF0Opt d I_, NDARO CORAPtbANCE. rig 4n EMC .............. FCC Parl75 flies B, IECb3000.b IEC61000-63 Y...... _... _ . ... I ................ .... IEC62109-1 (daa R safettrt, UL17H........--.................. I Maxnrwm Ai10- 10 Sy" V.ORW.. ............... 11.-......... .................. Cat patlhk Inverters ........ AN SWarCdae Sky(lePhase andThree PhaseuwertessOlmensiens(W xLxH) L78x152x7E/5 x5.97x11 128x151 x36/ 118x752x50/ 128x352x59( in 630 5a597x L42. _ Sx597x1% _ Wn ghL ( nJudns nhles)...... 14 a 0/ 7517 845 / L9 1064 f 2.3...(... N ........ Input CpxreUtx .. MC4P' Output Wire iype![-- don OoudelrrsrrWtE.vt .... Output Wirx L h i 095 / 3 0 L2 39 m ft Operating Tgmperature R! ng!.. ....1. 40.- 85 / -40.. .185 .... C Prdectlon Ratl.. t IP68/NFMA6P Relative..... y ase src r dx. x„px. seaa.d w a •sxw..rwertl..ee..e. 0-100 ._........... ...... in ra atM1er ronnnywprr.. ranrt igrFJEe7'W.$ S—_. IIWaSFGNUSING -.7 • ., 3LPiGLE PHASE A 9QUtAEOGErNV£RTER" QHO-WAVE S€HGLE'PNASE THREE PHASE 268V 5'iYltl3t5i MiMn1Urt151 nnqle R(ti 1 31U 1 )IU,PMJ Power Opdmirers( (P405 / P505 i 6 e 14 Maximum String Length 25 is W. Power Optlmiays(............................. ....... 57W(S000 wdth.._( Maximum Power per String SE'7600wus' 5250 600D127SO W SET 0(100H: UN ..... Par" Strings of Differe4 Lengths orQiarrt]tfans L!a a re, aw, nEemsxmerdorrxeex mr ro an*Ji+.,.r,dd.as.. mr r--,. ,m W her na dlewceb mk>A541 WI6P1X+/vittyViEC/PWC/rr6/E®fa M aw aM} at x MAn. ur t b+Nun m Arc. ..r. inn NEf r.yin rFur l vn -narwiw.n:lnY nal•..+. . . ••" •••.kW .Y+wrw solar=ee Single Phase Inverters for North America SE3000H-USiSE3800H-USISE5000H-USI SE600OH-US;'SE7600H-USiSE1000OH-US OpYionai, Revere grade data, ANSI f!.2.20 Class 0 5 !01,5% arc,rjc`ii VW:ANAIi ERM—uc-+:AIN: faNE! IifR—WVM H— A'3': n—AISPJtf! I RANC 3f-U.f:iaf.EYllCiq PVi'sM1A P(!MRMU MiMt ApyiKFMN 5 ' N AT"A PmN'f(1E<H RMN-NM1 solar=eeSingle Phase Inverters for North America SE3000H-US ! SE3800H-US / SE5000H-US / SE6000H-US/SE760OH-USISE1000UH-US Sf3f1UDIt US 5F3Niaktia5 SE900W1-IES.. ! SEb1100N DS SF 7600H u3 Sf1t100aK-US L Y. paledAC Paver Outputt Ah10 3LLOD 0DD 60M } 7 ,OD SOOW YA Max AC Power Uutpul V-W 3800 SE108 6000 7(if70 1COM VA putACOutYolligeMin. -Nam. I WC Max. j7lt 140 ;6+).......... J......... 1....... ACFtequetxy.(nondnpQ .... . Ma-Cormnuous Output 59.3.:60-6UM .... r entLM24fN„ 12536 21........ I.... ... 25 ..'I. 32...... I. - . a............ A GFDIThres1roW.........__.. utl8ty Monkoring, taanafng 1.......... .............................. A..... Pnotectfon. Country ConAgurah@ Tel IA _. i _...... ._...... .......... _....... .......... ...... A80.... .. ..... :.. . 380 ... ....... 400 Ydc 10V 8. 5 SUS ..) t6..... 20 I. 27.. i...!Mic gent .. .. ... . - aac wx Son 5001w 5etIsRFAix--... ....._........ :........... 2j.......... Inter............ Hs485. Ethernet, ZI9Bee (x7PWWI), Cellular (opftA revenue Grade Data, AN51 C1110-, ......... t?P..?.. Rapid Shutdown - NEC20tC andiAutomatic papown a Shutdupon ACGridDisconnect i-...... 2017 690.72-- fIt9PI, tA1NEE. ___ z.•t•- s. s, mxts'.^s - . Safety t .' ='' • n 5 38, CSA C72 2Canadian AfOacow6nafo TJ.L M-07 - GAaConnecT_nns- !arn If[ I t5a7, Rule 2l, pule t4 (HI} E(NSNM z f fs 1 Class8 wtQ%SpEC1AitOF75 - AC Output Coluluit Size / AGAVVG203/4' Innimum / 4Flaw. ........... _.... ..... _ DC Input Conduit Size / a of 5trif s AM Range 3(4' mbamum / i-2 sW tqc / t46 AWG 1-3sWngs / I......... ........_ _......... .......... ............ 9r?.a - DLmenslons with Safety Switch 17. 7.14.6.6.8/450x370x174 213 x 14,6 x 7.3/S40x370 in/mm HZWzOi Awth Saety Switch. ., ..... 27.I SU... _ L 251/SSA, 262/119 .. 38.8J176 Nalse<z5 i 11II c5U aea CooBnq -. ... Natural Comectl4n. l Natttfal COtweCiloO tiyeratu>8tempwature Raxt e, ..j. 1'i to e140{,-25 to e60u!('F/-40 CnptianN'I... F/ Plotectian Ratlng....................i.... ....... HEMA.3R( Imrcrter wHh SalelY Swlt[If%..... ......... I ............ .... ...................... M feaa.w.gb:ul4Mp pbflmrlslaxlr'EdR 0 lnan,elWxxnxrze. PM Sfaoa1fU900aNML'[ A. ponxr d fxxna x, wrnrlen Mw NNfx iww'dwe,w.•.,W eNV+aJ.NxNrimwnnu.,benu,,nr..,pdt a axrslm MN' Ymflll OrIINM AW IRONRIDGE Built for solar's toughest roofs. Flush Mount System IronRidge builds the strongest mounting system for pitched roofs in solar. Every component has been tested to the limit and proven in extreme environments. Our rigorous approach has led to unique structural features, such as curved rails and reinforced (lashings, and is also why our products are fully certified, code compliant and backed by a 20-year warranty. Strength Tested All components evaluated for superior structural performance. Class A Fire Rating Certified to maintain the fire resistance rating of the existing roof. UL 2703 Listed System Entire system and components meet newest effective UL 2703 standard. PE Certified Pre -stamped engineering letters available in most states. Design Assistant Online software makes it simple to create, share, and price projects. XR Rails XR10 Rall XR100 Rail XR1000 Rail Bonded Splices a:E A low -profile mounting rail The ultimate residential A heavyweight mounting All rails use internal splices for regions with light snow. solar mounting rail. rail for commercial projects. for seamless connections. 6' spanning capability 6' spanning capability 12' spanning capability Self -drilling screws Moderate load capability Heavy load capability Extreme load capability Varying versions for rails Clear & black anod. finish Clear & black anod. finish Clear anodized finish Forms secure bonding Clamps & Grounding UFOs Stopper Sleeves Universal Fastening Objects Snap onto the UFO to turn bond modules to rails. into a bonded end clamp. Fully assembled & lubed Bonds modules to rails Single, universal size 6 different sizes Clear & black finish Clear & black anod. finish Attachments C> Grounding Lugs Microinverter Kits to " Connect arrays to Mount Mls or POs to XR equipment ground. Rails. Low profile Bonds devices to rails Single tool installation Kit comes assembled Mounts in any direction Listed to UL 2703 FlashFoot2 Slotted L-Feet Bonding Hardware Flush Standoffs L-L Flash and mount XR Rails Drop in design for rapid rail Bond and attach XR Rails Raise Flush Mount System with superior waterproofing. attachment. to certified attachments. tovarious heights. Twist -on Cap eases install Secure rail connections T & Square Bolt options Works with vent flashing Wind -driven rain tested Slotfor vertical adjusting Nut uses 7/16" socket 4" and 7" lengths Mill & black finish Clear & black anod. finish Assembled & lubricated Ships assembled Resources Design Assistant NASCEP Certified Training 20-Year Warranty Go from rough layout to fully Earn free continuing education credits, engineered system. For tree. while teaming more about our systems. Twice the protection offered by competitors. Go to ironRidge.comtdosign Go to fronRidge.condtra'sning t RON RI DGE 1495 Zephyr Avenue Hayward, CA 94544 1-800-227-9523 IronRidge.com Attn: Corey Geiger, VP New Markets, IronRidge Inc. Date: December 20', 2017 Re: Structural Certification and Span Tables for IronRidge Flush MountSystem This letter addresses the structural performance and code compliance of IronRidge's Flush Mount System. The Flush Mount System is a proprietary rooftop mounting system used to support photovoltaic (PV) modules installed in portrait or landscape orientation and set parallel to the underlying roof surface. PV modules are supported by extruded aluminum XR Raiis and secured to the rails with IronRidge mounting damps. The XR Rails are side mounted to a selected roof attachment with 3/8" stainless steel bonding hardware and then attached directly to the roof structure or to a stanchion that is fastened to the underlying roof structure. Assembly details of a typical Flush Mount installation and its core components are shown in Exhibit EX-0015. The IronRidge Flush Mount System is designed and certified to the structural requirements of the following reference standards for the load conditions and configurations tabulated in the attached span tables: ASCE/SEI 7-10 Minimum Design Loads for Buildings and Other Structures (ASCE 7-10) 2015 International Building Code (IBC-2015) Florida Building Code 61' Edition (2017) Building 2015 Aluminum Design Manual (ADM-2015) The tables included in this letter provide the maximum allowable spans of XR Rails in the Flush Mount System for the respective loads and configurations listed, covering wind exposure categories B. C, & D, roof zones 1, 2 & 3, and roof slopes from 01 to451. The span tables are applicable provided that thefollowing conditions are met: 1. Span is the distance between two adjacent roof attachment points (measured at the center of the attachment fastener) 2. The underlying roof pitch, measured between roof surface and horizontal plane, is 45' or less. 3. The mean roof height, defined as the average of the roof eave height and the roof ridge height measured from grade, does not exceed 30 feet. 4. Module length shall not exceed the listed maximum dimension provided for the respective span table and module width shall not exceed 40". 5. All Flush Mount components shall be installed in a professional workmanlike manner per IronRidge's Flush Mount installation manual and other applicable standards for general roof construction practice. AW IRONRIDGE 1495 Zephyr Avenue Hayward, CA945" 1.800-227.9523 mriRfdge.com The span tables provided in this letter are certified based on the structural performance of IronRidge XR Rails only with no consideration of the structural adequacy of the chosen roof attachments, PV modules, or the underlying roof supporting members. It is the responsibility of the installer or system designer to verify the structural capacity and adequacy of the aforementioned system components In regards to the applied or resultant loads ofany chosen array configuration. ttL7rr sriry 7Sincerely, S0'yg9 % f, 2017 IronRidge, Inc. FL Flush Mount System Certification Letter - 1 M 2W Iror pkidg ' tno FL Flush Mount System Cert6cation Letter - 3 IRONRIDGE Background All roofing products are tested and classified for their ability to resist fire. Recently, these fire resistance standards were expanded to Include solar equipment as part of the roof system. Specfically, this requires the modules, mounting hardware and roof covering to be tested together as a system to ensure they achieve the same fire rating as the original roof covering. These new requirements are being adopted throughout the country in 2016. IronRidge Certification IronRidge was the first company to receive a Class A Fire Rating —the highest possible rating —from Intertek Group plc.. a Nationally Recognized Testing Laboratory. IronRidge Flush Mount and Tilt Mount Systems were tested on sloped and flat roofs in accordance with the new UL 1703 UL 2703 test standards. The testing evaluated the system's ability to resist flame spread, burning material and structural damage to the roof. Refer to the table below to determine the requirements for achieving a Class A Fire Rating on your next project. Class A Fire Rating Teat Setup Soto Modules Solar rrodules are given a Type ciassiftation based on their Wale and cwwhuction. e Mounting System IMountingmtestedaspartda systmn that inchOm rype-tesfea modules and fee -raced root covering. j Roof Gowning i Root covering products are giver, a Fire Class Rating of A, a or C based on theirtested fire resistance. ttt Surring Brand Test - - -- -' A burning wooden block is placed on module as a fan blows at12 mph. tFlarnscannotbeseenonundertWedroofrrMNn90minutes. FFFFf Spread of Flame Test i 4 Flame at southam edge of roof Is aimed up the rod as a fan blows at 12 mph Theflame cannot spread Ffeet a more in 10 minutes, is Flush Motet ae Any Slope Type 1, 2, & 3 Class A nit Mount s6 Degrees Type 1, 2, & 3 j Class A 1 t»+rrer.e oa ti Frequently Asked Questions What is a "module type"? The new UL1703 standard introduces the concept of a PV module type, based on 4 construction parameters and 2 fire performance parameters. The purpose of this classification is to certify mounting systems without needing to test it with every module. What roofing materials are covered? All fire rated roofing materials are covered within this certification including composition shingle, clay and cement tile, metal, and membrane roofs. What if I have a Class C roof, but the jurisdiction now requires Class A or B? Generally, older roofs will typically be "grandfathered in", and will not require re -roofing. However, 6 50 % or more of the roofing material is replaced for the solar installation the code requirement will be enforced. Where is the new fire rating requirement code listed? 201218C: 1509.7.2 Fire classification. Rooftop mountedphotovoltaic systems shallhave the same fire classification as the roofassembly required by Section 1505 Where is a Class A Fire Rating required? The general requirement for roofing systems in the IBC refers to a Class Cfire rating. ClassA or B is required for areas such as Wildland Urban Interface areas (WUI) and for very high fire severity areas. Many of these areas are found throughout the western United States. California has the most Gass A and B roof fire rating requirements, due to wild fire concerns. Are standard mid clamps covered? Mid clamps and end clamps are considered part ofthe PV "system", and are covered in the certification. More Resources Tech iitie# What attachments and flashings are deemed compatible with Class A? Attachments and their respective flashings are not constituents of the rating at this time. All codecompliant flashing methods are acceptable from a fire rating standpoint. What mounting height is acceptable? UL fire testing was performed with a gap of 5", which is considered worst case in the standard. Therefore, the rating is applicable to any module to roof gap. Am 1 required to install skirting to meet the fire code? No, IronRidge achieved a Class A fire rating without any additional racking components What determines Fire Classification? Fire Classification refers to a fire -resistance rating system for roof covering materials based on their ability to withstand fire exposure. Class A - effective against severe fire exposure Class B - effective against moderate fire exposure Class C - effective against light fire exposure What ifthe roof covering is not Class A rated? The IronRidge Class A rating will not diminish the fire rating of the roof, whether Class A, B, or C. What tilts is the tilt mount system fire rated for? The tiff mount system is rated for 1 degrees and up and any roofto module gap, ormounting height. Installation Manuals Engineering Certification Letters Visit our website for manuals that include UL We offer complete engineering resources 2703 Listing and Fire Rating Classification. and pre -stamped certification letters. Go to IronRidge.com Ga to iro inidge.com tn•.r<..eye, e. 'e a ,s.erved-b,sN , nn3,7 .. .,, t-2II.'2;-S523 me nrore hucm,rtwn, .eraY.m ' MODULE ! The Flush Mount System may be used to ground and/or mount a PV module complying with UL 1703 only when the specific module has been evaluated for grounding and/or mounting in compliance with the included instructions. Unless otherwise noted, "mot" refers to the module power rating and both black and silver frames are included in the certification. Modules with 35, 40, or 45mm frames and model identifier aaSM66yyPzz-xxx; where "as" is CH i Astronergy Solar orA;'j/tP is either 10 or 12; and "zz" is blank or (BL). Frameless modules with model identifier IICHSM6610P(DG)-xxx. j Axdec Modules with 35 or40mm frames and model identifier AC-xxxY/aa-ZZ; where'Y" is M or P; "aa' is 125 i or 156; and "ZZ" is 545, 60S or 72S. Canadian Solar Modules with 35 and 40mm frames and model identifier CSbY-xxxZ; where "b" can be 1, 3 or 6; "Y" can ' be K, P, U, V, or X; and "Z" can be M, P, AG, MS, PX , M-SD, P-AG, P-FG or P-SD, MS -AG, MS-FG, or MS -SD. Frameless modules with model Identifier CSbY-xxx-FG; where "b" can be 3 or 6; "Y" is K, X, or P; and 'W can be M-FG or P-FG. _ Solar Modules with 35, 40, or50mm frames and model identifier ET-Y6ZZxxxAA; where "Y" is P. L, or M; "ZZ'ET Is 60 or 72; and " is WB, WW, BB, WBG, WG, WBAC, WBCO, WWCO, WWBCO or BBAC. IsAA" W with 35, 40, or 50mm frames and model identifier FXS-)=YY-ZZ; where "xxx" is the module 3 Flex Illiii power rating; "YY" is BB or BC; and "ZZ" is MAA1 B, MAA1 W, MAB1 W, SAA1 B, SAA1 W, SAC1 B, 3 SAC1 W, SAD1 W, SBA1 B, SBA1 W, SBCt B, or SBC1 W. _ GCL Modules with 35 and 40mm frames and and model identifier GCL-a6/Yl' xxx, where "a" can be M orP and "W' can be 60, 72, or 72H. GigalWattSolarModuleswith40mmframesandmodelidentifierGWxXXYY; where "YY' Is either PB or MB. ^ it Modules with 40, 45, or 50mm frames and model identifier HSLaaP6-YY-1-xxxZ; where "aa" is either 60HanwhaSolaror72'YY" is PA or P8; and "Z" is blank or B. Modules with 32, 35, 40, and 42mm frames and model identifier aaYVZZ-xxx; where "aa" can be Q. or B.;'YY" can be PLUS, PRO, PEAK, LINE PRO, LINE PLUS, or PEAK D'JO; and "ZZ" can be G3, G3.1, Hanwha Q CELLS G4, G4.1, L-G2, L-G2.3, L-G3, L-G3.1, L-G3y, L-G4, L-G4.2, L-G4y, LG4.2/rAA, BFR-G3, BLK-G3, BFR-G3.1, BLK-G3.1, BFR-G4, BFR-G4.1, BFR G4.3, BLK-G4.1, G4/SC, G4.1/SC, G4.1/rAA, G4.1/ I MAX, BFR G4.1rrAA, BFR G4.1/MAX, BLK G4.1/rAA, BLK G4.1/SC, EC-G4.4, G5, BLK-G5, L-G5.2, or L-G5.2/H. Heliene Modules with 40mm frames and model identifier YYZZxxx; where "YY" is 36, 60, 72, or 96; and "ZZ" Is M, R or MBLK. Modules with 35, 40 and 50mm frames and model identifier HiS-YxxxZZ; where "Y" can be M or S; andHyundaiZZ' can be MI, MF, MG, SG, RI, RG(BF), RG(BK), TI, or TG. itek Modules with 40 or 50mm frames and model identifier fT-xxx-YY; where "YY" is blank, HE, or SE, or SE72. Modules with 35, 40 and 45mm frames and model Identifier JAyyzz-bb-xxx/aa; where "W can be M, P. M6 or P6; "zz' can be blank, (K), (L), (R), (V), (BK), (FA), (TG), (FA)(R), (L)(BK), (L)(TG), (R)(BK), (R) JA Solar TG), (V)(BK), (BK)(TG), or (L)(BK)(TG); "bb" can be 48, 60, 72, 60S01 or 72501; and "ae can be MP, SI, SC, PR, RE, 3BB, 4BB, 4BB/RE, SBB. - Modules with 40mm frames and model Identifier JKMYxxxZZ-aa; where 'Y" is blank or S; "ZZ" is P, Anko PP, M; and "aa" is 60, 608, 60-J4, 60B-J4, 60(Plus), 60-V, 72, or 72-V. Frameless modules with model identifier JKM)=PP-DV. Modules with 46mm frames and model identifier KYxxxZZ-AA; where "Y" is D or U; "ZZ" is blank, GX, or Kyocera SX; and "AA" is LPU, LFU, UPU, LPS, LPB, LFB, LFBS, LFB2, LPB2, 3AC, 313C, 3FC, 4AC, 413C, 4FC, 4UC, SAC, SBC, 5FC, SUC, BBC, 6FC, BBC, 6MCA, or 6MPA. LG Modules with 35, 40, and 46mm frames and model identifier LGxxxYaZ-bb; where "Y" is A, E, N, Q. S; a" is 1 or 2; "Z" is C, K, T, or W; and "bb" is A3, A5, B3, G3, G4, or K4. Longi Modules with 40mm frames and model identifier LR6-YY-xxxM; where "YY" can be 60, 72, or 72HV. Moduleswith 40mm frames and model identifier MSEx)o(Ma; where 'ZZ" can be MM, SE, SO orSQ; Mission Solar1 and "aa" can be 1J, 4J, 4S, 5K, 5T, 6J, 6S, or 6W. AWA MODUL66OMPATIBILITY Mitsubishi Modules with 46mm frames and model identifier PV-MYY=(ZZ; where "YY" is LE or JE; and "ZZ" is either HD, H02, or FB. Motech IM and XS series modules with 40, 45, or 50mm frames. _ Neo Solar Power Modules with 35mm frames and model identifier D6YxxxZZaa; where "Y can be M or P; "ZZ" can be 133A, B4A, E3A, E4A, H3A, H4A; and 'aa" can be blank, (TF), ME or ME (TF). Modules with 35 or 40mm frames and model identifier VBHNxxxYYzz; where "YY" is SA or KA; andPanasonicis01, 02, 03, 04, O6, 068, 11, 11B, 15, 15B, 16, 168, 17, or 18. a" Modules with 35, 40, or 45mm frames and model Identifier PS)=Y-27JA; where "Y" is M orP; "ZZ" Phono Solar is 20 or 24; and "A" is F, T or U. Prism Solar Frameless modules with model identifier BIYY xxxBSTC; where "YY" is 48 or 60. _ REC Solar Modules with 30, 38 and 45mm frames and model identifier RECXXXYYZZ; where "YY" is M, PE, I TP, or TP2S; and "ZZ" is blank, BLK, SLV, or 72. Modules with 35, 40 or 50mm frames and model identifier JCXxxY--ZZ; where "Y" is F, M or S; andRenesolaZZ' is Ab, Ab-b, Abli, Abh-b, Abv, Abv-b, Bb, Bb-b, Bbh, Bbh-b, Bbv, Bbv-b, Db, or Db-b. j R-enoo-g•-y- Modules with 40 or 50mm frames and model identifier RNG-xxxY; where "Y' is D or P. Modules with 40mmframes and model identifier SNxxxY-ZZ; where "Y" is M or P; and "ZZ" is 10, or S-Energy 15. Modules with 40mm frames and model identifier SEG-6YY-xxxZZ; where "YY" can be MA, MMPSeraphimEnergyGroupPB; and "ZZ" can be BB, WB, or WW I Modules with 40 and 50mm frames and model identifier SRP-xxx-6YY; where "YY" can be MA, MB, Seraphim USA PA, PB, QA-XX-XX, and QB-XX-XX. Sharp Modules with 35 or 40mm frames and model identifier NUYYxxx; where "YY" is SA or SC. _ Sitiab Modules with 38mm frames and model identifier SYY-Z-xxx; where "YY" is SAor LA; SG or LG; and M,P,orX. ._. r._---_.a Solaria Moduleswith 40mm frames and model identifier PowerXT)=YZZ; where "Y" can be R orC; and ZZ" is BX, BY, PX, PZ, WX or WZ SolarTech Modules with 42mm frames and model identifier STU-)=YY; where "YY' can be PERC or HJT, i Sunmodule Plus, Protect, XL, Bisun, Bisun XL, may be followed by mono, poly or duoand/or black ' SolarWorId or bk; modules with 31, 33 or 46mm frames and model identifier SW-xxx. Sfxm Thin film modules with 35mm frames and model identifier STO-xoor or STO-xxXA. Thin film frameless modules with model identifier STL-xxx or STL xxxA. Modules with 35, 40. or Somm frames and model identifier SE-YxxxZABCDE; where'T' is B, F, H, I SunEdison P, R, or Z; "Z" is 0 or 4; "A" is B. C, D, E. H,1, J, K, L, M, or N; "B" is B or W; "C" isAor C; "D" is3, i7, 8, or 9; and "E" is 0, 1 or 2. Modules with 35, 38, 40, 46, or 50mm frames and model identifiers OPTxxx-AA-B-YYY-Z Suniva or MVXxxx-AA-B-YYY-Z; where "AA" is either 60 or 72; "B" is either 4 or 5;'YYY" is either 100,101,700,160, or 1B1; and "Z' is blank or B. Modules with model identifier Ab-xxx-YY and standard (G3) or InvisiMount (G5) 46mm frame; Sunpower where "A" is either E, P or X; "b" can be 17, 18, 19, 20, 21, or 22; and "YY' can be blank, NE, BLK, COM, C-AC, D-AC, BLK-C-AC, or BLK-D-AC. Sunpreme Frameless modules with model identifier GXB-)=YY; where "YY' is blank or SL. Suntech Vd, Vem, Wdb, Wde, and Wd series modules with 35, 40, or 50mm frames. j Modules with 35,40 or 46mm frames and model identifier TSM-xxxYYZZ; where "YY" is PA05, PC05, PD05, PA4, PC14, PD14, PE14, or DDOS; and "ZZ" is blank, A, A.05, A.OB, A.10, A.18, .05, Trina 08, .10, 11 e, .OBD, .18D, 0.82, A.082(11), .002, .00S, OSS, OBS, A(11), A.08(II), A.05(II), A.10(ll), or A. 18(11). Frameless modules with model Identifier TSM-)=YY; and "YY" is either PEGS, PEG5.07, PEG14, DEGS(II), DEG5.07(11), or DEG14(II). 1 W nai Modules with 35 or 40mm frames and model identifier Wsy-XXKZ6; where "y" is either P or T; and e" is either M or P. Yingli Panda, YGE, and YGE-U series modules with 35, 40, or 50 mm frames. L-Mount I QMLM / QMLM2 Elevated Water Seal Technologye, THIS EDGE TOWARDS ROOF RIDGE NO, DESCRIPTION CITY. I FLASHING. ROUNDED CORNERS. r X IT X .040'. 5052, MILL 1 2 L-FOOT. 7 X 3.3T FOR AW' O.D. FASTENER. 606146/60DSA-761. MILL I 3 WASHER, SEALING. 5/16" ID X 3/4" OD. EPDM BONDED SS 1 LAGSCREW, HEX HEAD- 5116' x4". I88 SS 1 L-FOOT T X3.30', 2 X .7S' SLOT FOR .43W O.D. FASTENER, 6061- Tb 6005A-T61 MILL I 12.00 T 1 IE I ------ -- — 9.00 — -- 2.00 t— e>.397 3.30 < ^.90j I D40 3.Saj12501 , S... .. ..... .......... ... ...... . QMLM2: 2 X .75" SLOT VERSION OPTIONAL 0 0 o 2.00 0.397 TYP —I i — 1.0D l 75 T AVAILABLE IN MILL, AND BLACK FINISHES 25 i.la 75•1 - —— ... (kick Mount Fn/- ntLE QAUM2 QMLM: L-MOUNT, 5/16" LAG, 9" X 12" FLASHING m[xwge S'! SIZE - DRAoi a, PAD PE, uweID'-r:S.VEn F: A DAZE' emnov 5 a+Aaw oa, wwa. wuw rya. „ ...._ . nw 1 noen.ee wu :mr 4 3 2 Quick Mount Pv RESPECT THE ROOF L-Mount Installation Instructions Installation Tools Required: tape measure, roofing bar, chalk line, stud finder, caulking gun, sealant compatible with roofing materials, drill with 7/32" bit, drill or impact gun with 1/2" socket. WARNING: PV prciduct are NIOT dlesicincd for and hould NOT be Used tounchor tall pro' teclion eqUII)ITIOnt. Locate, choose, and mark centers of rafters to be Carefully liftcomposition roofshinglewith roofing Insert flashing between 1st and2nd course. Slid: mounted. Select the courses of shingles where bar, just above placement of mount. Remove up so top edge of flashing is at least 34" higher mounts will be placed. nails as required and backfill holes with aproved than the butt -edge ofthe 3rd course and lower sealant. See "Proper Flashing Placement" on nevt Flashingedgeis above the butt -edge of 1stcourse. page. Markcenter fordrilling. Using drill with 7/32" bit, drill pilot hole into roof Clean off anysawdust, and fill hole with sealant Place Ufoot onto elevated flute and rotate L-foot to and rafter. taking care to drill square tothe roof. compatible with roofing materials. desiredorientation. Donot use mount as a drill guide- Drill a 2" deep hole into rafter. Prepare lag bolt with sealing washer. Using a 112 You are now ready for the rack of your choice. inch socket on an impact gun, drive prepared lag Follow all the directions of the rack manufacturer bolt through L-Foot until L-foot can no longer easily as well as the modute manufacturer. NOTE Make rotate. DONOTover-torque. sure top ofL-Foot makes solid contact with racking. 817.2.3-44 Jun-2017 Rev 017.2.3-44 Jun-2017 Rev 2 8 ARE SUBJECT TO THENOTICE AND CURE PROVISIONS; ANY CLAIMS FOR CONSTRUCTION DEFECT 'PROV, 558 FLOFCk'AP-tEf( STATUTES. W7991A Scanned with. CarnScanner 6. CONTRACT; DOCUMENTS.; Thi s drawings andapeq fications and any to -as the Contract t)ocuments1. ,TI Documents. This Contract:and.the-i this'Contract and upersedoall prior by a written tlocument duly.executed 7. PRICING-AND;PRODUCTS:. Th significant price increases in constru of the Work,, shall cause,the Cgntra reservesafle right to make:adlustmei he final, construction , 14. TERMINATION: Ifyou cancel this agreement after the three business day right of rescission, Contractor may change a cancelation fee< equal to 25% of,ihe Contract:Price or the yalue ofthe labor and/or materials provided whichever is greater. 15. UTILITY RATES AND RATS STRUCTURES: Utility rates andut ty rate structures,ate sutiject to change.: ,These changes, cannot be v.t 1867s93.vr Scanned with CamScanner REQUIRED INSPECTION SEQUENCE IRIP0" I4 _loci_ - - i "]'UIQItdD1GNTQs I Min Max Footer / Setback Stemwall Foundation / Form Board Survey Slab /' Mono Slab Prepour Lintel / Tie Ream / Fill / Down Cell Sheathing- walls Sheathing- Roof' RoofIvry Ins Frame Insulation Rough In Firewall Screw Pattern Drywall / Sheetrock Lath Inspection Final Solar Final Roof Final Stucco / Siding . Insulation Final Final Utility Building Final Door Final window Final. Screen Room Final- Pool Screen, Enclosure Mobile Home Building Final. Pre - Demo Final Demo f Final Single Family Residence I Final Building. )(Other) Min Max1[ns De C ll®Il]l IDescII°ll DtIloIIIl Plumbing Underground Plumbing Sewer Plumbing Tub.Set Plumbing Final 4 k Q i m '" ..s 1 Mn Max I(ns ection DescCrijetion Mechanical. Rough Mechanical. Final. ip fi MM* Max Yms eetionn. )<Deseri Lion { Gas Underground Gas Rough Gas Final ft EWS ED: June 2014 IiII=1 5111110I 0li1-21l1]i 11IF:zIffy_ Altamonte Springs, Casselberry, Lake Mary, Longwood, Sanford, Seminole County, Winter Springs Date: Ta' 41 I hereby name and appoint: Ili6 e i Rwwgi an agent of: B P., A rto, (r1bJ e of Company) to be my lawful attorney -in -fact to act for me to apply for, receipt for, sign for and do all things necessary to this appointment for (check only one option): The specific permit and application for work located at: Street Address) Expiration Date for This Limited Power of Attorney: -0-Li. 19 License Holder Name:QiA-p Cyr(Oetr) State License Number: ECIa t)G U k-+3 Signature of License Holder: STATE OF FLORIDA COUNTY OF T irllc s The foregoing instrument was acknowledged before me this 6-14 day of , 200 / t , by &t-. a 0yr(otI o who is persona ly known to me or who has produced Y3 as identification and who did (did not) take an oath. Signat6rre----1 Notary Sea]) I-4 Print or type name Notary Public - State of Fc- Commission No. F dtgUB -4 My Commission Expires: l f a -(4 STEPHANIE STEPHENS Rev. 08.12) MY COMMISSION #t FF213087T EXPIRES April 07, 2019 i`_,F:'F,'5;% FbnAaYotayServicr_.com Permit Number. Folio/Parcel ID #: I U-2u-3u-b- Prepared by: Palm Bay Electric LLC 247 Rheine Rd Palm Bay FL 32907 Return to: STFPHA IIF ('fIFFFV 2512 BAY FIFI Q c:T HOLIDAY FL 34691 NOTICE OF COMMENCEMENT State of Florida, The undersigned hereby gives notice that improvement will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement. 1. Description of property (legal description of the property, and street address if available) LOT 98 STERLING WOODS PB 54 PGS 93 THRU 95 - 127 PINE ISLE DR SANF,ORQ- FL 32773 2. General description of improvement Install kw PV solar system 3- Owner ' ormatign or Lessee information if the Lessee contracted for the improvement Name P i Address VXVI Vine IS 7' Interest in Property Owner Name and address of fee simple titleholder (if different from Owner listed above) Name Address 4. Contractor Name BLUE SKY SOLAR ENERGY - OTTO CURBELO Telephone Number 321-243-4808 Address 247 Rheine Rd, Palm Bay FL 32907 5. Surety (if applicable, a copy of the payment bond is attached) Name Telephone Number Address Amount of Bond $ 6. Lender Name- Telephone Number Address 7. Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by §713.13(1)(a)7, Florida Statutes. Name Telephone Number Address 8. In addition to himself or herself, Owner designates the following to receive a copy of the Lienoes Notice as provided In §713.13(1)(b), Florida Statutes. Name Telephone Number Address 9. Expiration date of notice of commencement (the expiration date will be 1 year from the date of recording unless a different date is specified) WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE F YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON OB SI FORE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR O E ORE C MENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. FRANCIS CLEMENTE Signature of Owner or Lessee, or Owners or Lessee's Authorized OffloerlDireotor/PertneNManager Signalmy's TinetOffioe The foregoing instrument was acknowledged before me this 20 day of 7/2018 by FRANCIS CLEMENTE HOMEOWNER rwm9fPerson as for Type of sw ority. e.g., officer. trustee. attorney in fad Name cfparty on behalf of whOln Instrument was executed S ar NOlary Pu — State of Florida Personally Known OR Produced ID X Type of ID Producedd Form content revised: 01/23114 STEPHANIE STEPHENS Print, type. or stamp commissioned name of Notary PubtiC STEPHANIE STEPHENS MY COMMISSION # FF218087 T,a! EXPIRES Aprd 07.2019 p,K,K.o,a.yge,vluwn GRANT MALOY, CLERK OF CIRCUIT COURT SEMINOLE COUNTY FL CLERK'S # 2018085709 BK 9179 Pg 1995: (1pg) E-RECORDED 07/24/2018 03:20:11 PM 10.00