340 San Lanta Cir - BR18-002865 - RENOVATIONSCITY OF Building &Fire Prevention DivisionORD _ UN 2 6 PERMIT APPLICA TION FIRE OEPARTMEN7 Application No: O 6 Documented Construction Value: S 55,370 Job Address: 340 San Lanta Circle Sanford, FL 32771 Historic District: Yes No Parcel ID: 31-19-31-505-0000-1110 Residential Commercial Type of Work: New[] Addition Alteration Repair Demo Change of Use Move Description of Work: Rehab-, new windows and exterior doors, Plumbing - new shower/tub/ hotwater heater Electrical- replace all switches/outlets/fixtures. HVAC- switchout painting/drywall repairs Plan Review Contact Person: pat lynch Title: Ares Phone:407-227-7715 Fax:407-228-1338 Email•plynch7@cfl.rr.com` Property Owner Information Name Ella Jones Street: 340 San Lanta cr City, State Zip: Sanford, FL 32771 Name Pat Lynch Construction Street: 909 Dennis ave City, State zip: Orlando, FL 32807 Phone: Resident of property? : owner Contractor Information Phone: 407-896-2776 Fax: 407-228-1338 State License No.: CGC043429 Architect/Engineer Information Name: Phone: Street: Fax: City, St, Zip: E-mail: Bonding Company: Address: Mortgage Lender: Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE' RECORDING YOUR NOTICE OF COMMENCEMENT. Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit roust be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. FBC 105.3 Shall be inscribed with the date ofapplication and the code in effect as of that date: 61° Edition (2017) Florida Building Code Revised: January I, 2018 ' ' S q . 3S Permit Application NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner ofthe property ofthe requirements ofFlorida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal. The actual construction value will be figured based on the current 1CC Valuation Table in effect at the time the permit is issued, in accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value, credit will be applied to your permit fees when the permit is issued. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating constsutt o ano io - Signature ofOwner/Agent Date ature of ni gent Date W 1 aHrtU. • 1111PrintOwner/A entsName Print Contractor/Agent's Name \\\\\\% yi SQ(f j5 ON XAj ••,y C` Signature o 0 on = Fate • o_ Signe late ofFlorida ate ar• i4 BorArA : p BL 40 >\. Owner/Agent is ersonally Known to Contractor/Agent is Personallyto a or Produced ID Produced ID BELOW IS FOR OFFICE USE ONLY Permits Required: Building pf Electrical V Mechanical N Plumbing Gas Roof Construction Type: Occupancy Use: Flood Zone: Total Sq Ft of Bldg: Min. Occupancy Load: of Stories: New Construction: Electric - # of Amps Plumbing - # of Fixtures Fire Sprinkler Permit: Yes No # of Heads APPROVALS: ZONING: ENGINEERING: COMMENTS: UTILITIES: FIRE: Fire Alarm Permit: Yes No WASTE WATER: BUILDING: SF 9-Zo•t:?, Revised: January 1, 2018 Permit Application l Revision O Response to Comments AUQ 0 201$ T I Permit # —/.r//;//i'D Submittal Date Project Address: Contact: City of Sanford Building & Fire Prevention Division Ph: 407.688.5150 Fax: 407.688.5152 Email: building@sanfordfl.gov 6 Jo l Ph: Z 7— -e-ell Fax: 7-ZZ Email: Trades encompassed in revision: General description of revision: a (es Building p s rH G v1' 3 /ai¢ -i Plumbing Electrical Mechanical Life Safety Waste Water Department Utilities Waste Water Planning Engineering Fire Prevention ROUTING INFORMATION Approvals 0 Building 5"S' Z-0'(a CITY OF SkNF0RD BUILDING DIVISION PLAN REVIEW COMMENTS Application Number: 18-2865 Date: 08.06.18 Project Description: Residential Alteration Contact Name: Pat Lynch Job Address: 340 San Lanta Circle Contact Email: plynch7(a)cfl.rr.com This is a general overview for code compliance in accordance with the minimum plan review required by the Florida Building Code. It is not a complete detailed review. The comments noted in this review must be addressed before the plans can be approved. Changes to plans shall be submitted on the same size format as the original submittal — changes in letter form are not permitted. All references to FBC Chapter I are as amended by City of Sanford ordinance viewable on our website at www.sanfordfl.gov. Provide two conies of affected plan sheets and/or supplemental information as requester. Permit subnunals will not be accepted without two copies. COMMENTS: 1. Two (2) copies of an exterior wall floor plan showing the location of each window & door that will be replaced. FBC 107 2. Two (2) copies of Florida Product Approval and corresponding installation instructions for the windows and exterior doors. FBC 107 Any error or omission in this plan review shall not be construed to grant approval of any violation of any of the adopted codes or municipal ordinances ofthis jurisdiction. Office meelinps wills the plans examiner to discuss comments will require an appointment, arranged by phone or email prior to arrival. Respectfully, Steve Fiorey, CBO Deputy Building Official 11111111111111111111111111111111 fill 1111 THIS INSTRUME PREPARED BY: Name: v Address: 7 NOTICE OF COMMENCEMENT GRANT CLERK, OFLCIRCUITIGOLEURTC UCTY OMPTROLLERBK, 9159 P9 2 (1P9s) CLERK'S : 2018072294 RECORDED 06/25/201E 08:14:35 AllRECORDINGFEES $10.00 RECORDED BY hdevore Permit Number. Parcel ID Number — " The undersigned hereby gives notice that improvement will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice ofCommencement. Fee Simple Title Holder (f other than owner listed above) Name: S. SURETY (If applicable, a copy of the payment bond is attached): Name* Address: Amount of Bond: S. LENDER: Name: Phone Number. Address: T. Persons within the State of Florida Designated by Owner upon -whom notice or other documents maybe served as provided by Section 713.13(1)(a)7., Florida Statutes. Name: Phone Number. Address: S. In addition, Owner designates Of to receive a copy of the Lienors Notice as provided in Section 713.13(1)(b), Florida Statutes. Phone number. 9. Expiration Date of Notice of Commencement (The expiration Is 1 year from date of recording unless a different date is specified) WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13. FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. E -W VIZJ7 we-4 Signature o1Owner or lessee• or Owners or Lessees Prinr Name and OrovWs Signatory s Ttgd019ce) Auftitted0fter ractor/PartnedManager) State of Countyof -W The foregoing instrument was acknowledged be re me by U-pt Name ofPerson makingNa' J who has produced identification 0 type of ide ": CERTIFCOPY GPa1TMALOY, CLERK OF iE CIRC SIT COURT 8oi`a' ANDOMPTRf ',%;,t` ji ; T 9Tf111'` SEMI' OLEC' f FI , Il7:a I ALIC, r BY _ ;? UiY CLERK day of 24Z Wh rs personally known to me OR Notary 6/19/2018 SCPA Parcel View: 31-19-31-505-0000-1110 o,.lo ianre,t rn PPr Record R iPAPP pady Card Parcel: 31-19-31-505-0000-1110 scnavo toounnv ntx. I. I Property Address: 340 SAN LANTA CIR SANFORD, FL 32771 t Parcel Information — -- .--- --- -- - - -.- -- -- -- — - — Parcel 31-19-31505-00001110 - -- -- — — - I ' Owner(s) JONES. ELLA L Property Address 1340 SAN LANTA CIR SANFORD, FL 32771 Mailing 1340 SAN LANTA CIR SANFORD, FL 32771-2983 — JSubdivisionName' SAN LANTA 3RD SEC j Tax District St-SANFORD , I DOR Use Code 101SINGLE FAMILY Exemptions 00-HOMESTEAD(1996) WAO` - 75.12 47.46 O h e- nole County GIS. Value Summary Certified2018Working I ValuesValues97Values Valuation Method Cost/Market Cost/Market iNumberofBuildings Depredated Bldg Value 68,130- 58,949 Depredated EXFT Value Land Value (Market) 18,000 15,000 Land Value Ag Js s Market Value -• - S86,130 73,949 Portability Adj --- - Save Our Homes Adj • 28,150 17,162 I Amendment 1 Adj 0 P&G Adj `$0 0 -1 Assessed Value - - 57,980 56,787 - Tax Amount without SOH: $633.37 i 2017 Tax Bill Amount $520.63 Tax Estimator Save Our Homes Savings: $112.74 Does NOT INCLUDE Non Ad Valorem Assessments Legal Description - - - - - - - - - - LOT 111 SAN LANTA 3RD SEC i PS 13 PG 75 Taxes ITaxingAuthorityAssessmentValue- Exempt values Taxable Value County General Fund Schools 57,980 32.980 25.000 +' 57,980 25.000 32.980 1jCitySanford57,980 - 32,980 25,000 fSJWM(Selnt Johns Water Management) 57,980 32,880 County Bonds - - 57' 25,0 980 32.980 . 25,000 Sales IDescriptionDate Page Amount—TOualfiedWARRANTYDEED- - 3/1/1995 02900 1331$49,000 Yes Vac/Imp= Improved I1WARRANTYDEED7/1/1978 01178 - 049 -- - - $23,000 Yes Improved Land-- Method Frontage I DeptA Units Units Price LLOT 00- 1 Land Value0. 0 00 - - 18.000.00 $18,0OOD Building Information n__in : r c Cli k_Here. - - i Description I Year Built F 8 i IAttuTectiveBath Base Area Total SF Living SF Ext Wall Adj Value Repl Value Appendage1SINGLE1971IFAMILY 5 3 y5 : 1,050 1,477 1,270 BRICK+WOOD ' 68,130' $92,067 i 1 I COMBO Description Area I UTILITY 99.00 Ihnp://Parceldetail.SCpafl.org/ParcelDetaillnfo.aspx?PID=31193150500001110 1/2 StA. INOL E COUNT)., l hIL TOC IR ISDIC-TICWA L LIMITED POWER OF ATTORNEY Altamonte Springs, Casselberry, Lake Mary, Longwood, Sanford, Seminole County, Winter Springs Date:dil I hereby nan an agent of: to be my lawful attomey-in-fact to act for me to apply for, receipt for, sign for and do all things necessary to this appointment for (check only one option): All pen -nits and applications submitted by this contractor. Or ' The speck permit and application for work located at: Street Address) Expiration Date for This. Limited Power of Attorney: License Holder N State License Number. CT C 1 Z 17 6 I ' C SC I 7S'3c7 Signature of License Holder. STATE OF FLORIDA COUNTY OFC_ , The foregoing instrument was acknowledged before me this day of 20, by ('' who is persotrall now- o or 0 who has produced as identification and who did (did not) take an oath. ig atun; of NotarM Print or type No name Notary Public - State of Commission No. My Commission Expires: 2 Board of County Commissioners WORK ORDER SEMINOLE COUNTY FLORIDA Work Order Number: 6 Master Agreement No.: RFP-1294-17/TAD Dated: Auaust 9. 2017 Master Agreement Title: MSA for Community Services Residential HOME, SHIP. NSP. & CDBG Rehabilitations Project Title: Rehab HOME Project at 340 San Lanta Circle, Sanford FL. 32771 Contractor: Pat Lynch Construction, LLC. Address: 909 Dennis Avenue Orlando FL 32802 ATTACHMENTS TO THIS WORK ORDER: METHOD OF COMPENSATION: X] Scope of Services — Attachment "A" X] Fixed fee basis X] Addenda — Attachment "B" Time basis -not -to -exceed X] Bid/Pay Items— Attachment "C" Time basis -limitation of funds X] Reconstruction Standards — Attachment "D" Retainage shall be withheld TIME FOR COMPLETION: The Work to be provided by the CONTRACTOR shall be substantially comp!eted as described in subsection 14.13 of the General Conditions, within one hundred twenty (120) calendar days after the date when the Contract Time begins to run as provided in subsection 2.2 of the General Conditions. The Work shall be finally completed, ready for Final Payment in accordance with subsection 14.9 of the General Conditions, within thirty (301 calendar days after the -actual date of Substantial- Completion. Failure to meet the completion time shall be grounds for Termination of both the Work Order and the Master Agreement for Default. WORK ORDER AMOUNT: FIFTY FIVE THOUSAND THREE HUNDRED SEVENTY AND NO DOLLARS 001100 ($55,370.00) IN W S WHEREOF a parties hereto have made and executed this Work Order on this Z—day of 20 for the purposes stated herein. 1 ATTEST/WITNESS: By: Secretary at )n CORPORATE SEAL) Dat : J, BOARD OF COUNTY COMMISSIONERS SEMINOLE COUNTY, FLORIDA WITNESSES: By: Prmra rznt AM") Diane Reed, Procurement Administrator Prowrement Analyst) 03 # 811969 Date: As authorized by Section 3.554 Seminole County Administrative Code. OM # of OC# 812004 Work Order —Contracts, Rev 11/14/11 Page 1 of 3 itCITY OF SWORD FIRE DEPARTMENT Building & Fire Prevention Division HVAC (NEWAND CHANGEOUT) PERMIT GUIDELINES All permit application packages must be complete prior to acceptance. You must check each box to the left or indicate n/a on this submittal. A complete application package shall include the following: O Building Permit Application completed, signed and notarized. Application must include correct address and complete parcel I.D. number. O Copy of a contract, signed by the contractor and the property owner, indicating the documented construction value O Copy of applicable contractor's license issued by the State of Florida (if the contractor is the applicant). O A site specific notarized power of attorney shall be required from the licensed contractor if he/she appoints an employee of his/her company to sign the permit application as the contractor. O Certificate of insurance indicating worker's compensation insurance coverage and naming the City of Sanford as certificate holder, or a copy of a worker's compensation exemption issued by the State of Florida (must be submitted with each application if contractor is the applicant). O Owner Builder Statement / Affidavit (if the owner is the applicant). Must be signed in person at the Building Department) O One (1) copy of equipment sizing calculations — for new construction installations: o Residential - ACCA Manual J-2003 or other approved heating and cooling calculation methodology. o Commercial - ACCA Manual N-2005 or other approved heating and cooling calculation methodology. O Addition or alteration of duct work, including new construction installations, requires two (2) copies of a floor plan (duct layout) showing the location of the ducts, the size of the ducts and the register sizes. This will require a plan review These guidelines were compiled to assist the applicant in preparing a HVA C change out permit application and may not be complete. The applicant is required to meet all City ofSanford, state, andfederal code requirements. Effective: August 1, 2017 RECORD COPY U REVIEWED FOR CODE COMPLIANCE PLANS EXAMINER PATE SANFORD BUILDING DIV1 PION A PERMIT ISSUED SHALL BE CONSTRUED TO BE A a LICENSE TO PROCEED WITH THE WORK AND NOT ASAUTHORITYTOVIOLATE, CANCEL, ALTER OR SET ASIDE ANY OF THE PROVISIONS OF THE TECHNICAL CODES, NOR SHALL ISSUANCE OF A PERMIT PREVENTTHEBUILDINGOFFICIALFROMTHEREAFTER REQUIRING A CORRECTION OF ERRORS IN PLANS, CONSTRUCTION OR VIOLATIONS OF THIS CODE Stt IErJ`EN;Tt SBcTtol.1S 9 Atz aS Szt..9 2.-E to SPEctto,J 1, I q\ r\ G W Attachment A" COMMUNITY SERVICES DEPARTMENT SL;1,111\JC 1T_ COUNTY COMMUNITY DEVELOPMENT DIVISION \ 7 ,"1 f SCOPE OF WORK / REHAB ESTIMATE FOR: 340 SAN LANTA CIR-SANFORD, 32771 YEAR BUILT:1971 EXTERIOR WALL: CONC BLOCK PARCEL NO. 31-19-31-505-0000-1110 THE SCOPE BELOW BRIEFLY DESCRIBES THE WORK TO BE PERFORMED AND SHALL MEET ALL TECHNICAL SPECIFICATIONS AND REHABILITATION STANDARDS SET FORTH BY SEMINOLE COUNTY COMMUNITY DEVELOPMENT DIVISION Each Division of Work requested must include all labor, material, overhead, profit, insurance, permits, variances, and subcontractor cost associated with performing the work. DIVISION 2 - EXTERIOR SURFACES: PRESSURE WASHING 2 00 Pressure Wash all exterior surfaces clean regardless of whether it is a painted surface body or not. Driveways, sidewalks, porches, eves, soffits, carports etc. Sub -total: $.00 DIVISION 2 EXTERIOR SURFACES: Wood work Repair rotted sections of sidine on front and right side of home. Install hardie paneling over existing sidine and paint. Remove and replace rotted section of soffit covering on roof with hardie board. Sub -total: $.00 DIVISION 3 - OPENINGS AND PROTECTION: EXTERIOR DOORS AND FRAMES 3 00 Remove and replace all exterior doors. Two in front, right side, and closed in carport doors shall be six 6) panel pre -hung type, with no glass in these doors. Main entry door to include lever type lockset nickel/satin finish), deadbolt and peephole. Doors to be keyed alike. Install new sliding glass door, must be LOW E glass with white frame. Install vertical blinds for slider. Repair any exterior wood, plaster, or drywall affected by this work as necessary. Sub -total: $.00 Seminole BCC Scope of Work Keith Welty/340 San Lanta Circle -Sanford, FL Revised: May 10, 2018 Attachment A" COMMUNITY SERVICES DEPARTMENT COMMUNITY DEVELOPMENT DIVISION SL-i1-l wc L f Couiv7-Y is '•'il .. \_+, , •, •I : u, DIVISION 3 - OPENINGS AND PROTECTION: INTERIOR DOORS AND FRAMES 310 Remove and replace all interior doors (prehung) including bedroom, bathrooms, utility room, and AC air handier door. Remove replace all closet doors with bi-folds or sliding pass through style. Include for all new hardware and lever type privacy locksets (nickel/satin finish). Any resulting damage to walls or floors is to be repaired to match adjacent areas in material and texture. Sub -total: $.00 DIVISION 3 - OPENINGS AND PROTECTION: WINDOWS 3 20 Remove and replace in original size and location all windows. Windows shall be white vinyl framed, single hung with LOW-E glass. All bathroom windows shall be obscure Blass. Each window shall receive a half inch (W) thick marble or wood window sill. New sill must protrude past the interior wall finish by at least one inch (1"). All windows are to receive 1" blinds. Windows inside closed in carport are not being changed. Remove bars on windows and sliding Glass door and leave near shed for the homeowner. Windows shall meet all current code requirements pertaining egress, hurricane wind born debris, accessibility and minimum Energy Star Rated classifications. Contractor shall repair any damage to interior or exterior returns, walls or floor resulting from this job. Sub -total: $.00 DIVISION 4—FINISHES: FLOORING 4 00 Remove and replace all ceramic tile floors throughout home including kitchen, bathrooms, hallways, bedrooms, and utility room. Sub -total: $.00 DIVISION 4 — FINISHES: GENERAL DAMAGED AREAS 410 Repair any damaged drywall areas (gouges, holes, scrapes, nicks, cuts). Include removal of popcorn from all ceilings repair as needed, and apply knock down. All baseboards are to be replaced. Sub -total: $.00 DIVISION 4 FINISHES: Utility room/Enclosed carport Repair sections of paneling where needed in utility room and paint. Enclosed carport is to only be painted. Sub -total: $.00 Seminole BCC Scope of Work Keith Welty/340 San Lanta Circle -Sanford, FL Revised: May 10, 2018 Attachment A" COMMUNITY SERVICES DEPARTMENT COMMUNITY DEVELOPMENT DIVISION DIVISION 4 — FINISHES: PAINTING INTERIOR 4 20 All interior wall surfaces and ceilings to receive one (1) coat of primer and two (2) coats finish paint. Color to be selected by Homeowner. Ceilings to be white Sub -total: $.00 DIVISION 4 — FINISHES: PAINTING EXTERIOR 4 30 All exterior wood surfaces to receive one (1) coat of primer and two (2) coats finish paint. Color to be selected by Homeowner. Sub -total: $.00 DIVISION 5 — PLUMBING: WATER HEATER 510 Remove and discard the existing water heater and all related components. Provide and install a new, Enemy efficient 40 gallon GAS water heater in existing laundry room location. Need to add 4"ventilation pipe through exterior wall with wall cap. Sub -total: $.00 DIVISION 5 — PLUMBING: DRAIN LINES 5 20 All drain -lines to be snaked -out before and after rehab of home. All drains must be working properly at time of final inspection. Sub -total: $.00 DIVISION S PLUMBING Install new handle for rear hose bib. Sub -total: $.00 DIVISION 5 — PLUMBING: BATHROOMS / MASTER BATH 5 30 Remove all plumbing fixtures. Remove shower surround and install %" hardie backer board with tile. Replace toilet with HC toilet, replace vanity/sink, light fixture, medicine cabinet, and all plumbing accessories including angle stops. Vanity top will be cultured marble with built in sink and overflow. Relocate light switch and remove recessed towel rack to match adjacent walls. Add an exhaust fan for bathroom controlled by switch. Sub -total: $.00 DIVISION S — PLUMBING: BATHROOMS / HALL 5 40 Remove all plumbing fixtures including tub and tub surround. Replace tub surround with %" hardy backer board and tile. Remove and replace toilet with HC toilet, replace light fixture, vanity/sink, medicine Seminole BCC Scope of Work Keith Welty/340 San Lanta Circle -Sanford, FL Revised: May 10, 2018 Attachment A" COMMUNITY SERVICES DEPARTMENT S%'i1,//PVul.f COCIlvl Y COMMUNITY DEVELOPMENT DIVISION I;. \'•:t `"•< < cabinet, and all plumbing accessories including angle stops. Vanity top will be cultured marble with built in sink and overflow. Remove recessed towel rack and repair drywall to match adjacent walls. Add an exhaust fan for bathroom controlled by switch. Sub -total: $.00 DIVISION 6 — KITCHEN: APPLIANCES 6 00 Refrigerator shall be a minimum eighteen cubic feet (18 cu.ft.) 610 Range hood vent will be a recirculating type 6 20 Remove and replace a food waste disposal unit. Appliances will be either white or black as selected by homeowner. Gas ranee stays Sub -total: $.00 DIVISION 6 — KITCHEN: 6 00 Install a new Stainless steel double -basin 60 40 drop -in sink with a minimum 8" depth with retractable spray nozzle fixture. Kitchen faucet will be a single lever Moen brand product equal to or better and meet handicap approved requirements. Light fixture in kitchen stays. Any damage to existing cabinets or flooring will be repaired Sub -total: $.00 DIVISION 7 — HEATING, VENTILATING and AIR CONDITIONING: 7 00 Provide and install a new complete HVAC Heat Pump system of appropriate capacity to service this residence. Unit must be a minimum 15.0 SEER rating. Replace all registers (grills) throughout house. Repair or replace air handler platform with proper bracing, new plywood, and duct board. Install filter back grill. All installations to be in strict compliance with all applicable codes and specifications. Repair any damage to walls, ceilings or floors that may occur as a result of this installation. All repairs to match adjacent finished areas. Sub -total: $.00 DIVISION 7 CEILING FANS/LAMPS 710 Remove existing ceiling fans and replace with new combo fan/light fixtures. Repair any wall or ceiling areas affected by this work to match adjacent finished surfaces. Sub -total: $.00 Seminole BCC Scope of Work Keith Welty/340 San Lanta Circle -Sanford, FL Revised: May 10, 2018 Attachment A" COMMUNITY SERVICES DEPARTMENT COMMUNITY DEVELOPMENT DIVISION DIVISION 8 —ELECTRICAL: Remove and replace weather head. Re -install cover on electric panel and clean up panel. Wires exiting panel need to be incased in conduit (sleeved). Any wires exiting panel that aren't being used can be deleted or run new. Repair any damages caused by performing work Sub -total: S.00 DIVISION 8 — ELECTRICAL: INTERIOR/EXTERIOR WMINAIRES 8 00 Remove and replace all existing interior and exterior light fixtures throughout the home. Repair any wall or ceiling areas affected by this work to match adjacent finished surfaces. Light fixture in kitchen stays. Sub -total: $.00 DIVISION 8 — ELECTRICAL: RECEPTACLES 810 Remove and replace all receptacle outlets, general lighting switches and faceplates throughout the home. Install arc fault outlets if needed. Repair any damaged or distressed wiring. Bathrooms will need added switch for exhaust fans. Sub -total: $.00 DIVISION 8 — ELECTRICAL: GFCIs INTERIOR / EXTERIOR 8 20 Ensure that GFCI protected receptacles are adjacent to all wet areas in the kitchen and all bathrooms as per Code. Install one (1) exterior GFCI protected receptacle with approved box, either by condenser or near electrical panel. Sub -total: $.00 DIVISION 8 — ELECTRICAL: SMOKE / CARBON MONOXIDE ALARMS Seminole BCC Scope of Work Keith Welty/340 San Lanta Circle -Sanford, FL Revised: May 10, 2018 Attachment A" COMMUNITY SERVICES DEPARTMENT I Sl::/\//ll\IQl_ t coul\a Y' COMMUNITY DEVELOPMENT DIVISION 8 30 Provide and install new smoke / carbon monoxide alarm system for this house as required by Code. Alarms to be hardwired, equipped with battery back-up, and interconnected. Sub -total: $.00 LEAD -BASED PAINT: Year Built 2971 This home is a pre-1978 home. According to Federal requirements, Contractor will be responsible for obtaining a Lead -Based Paint Inspection. If work is over $25,000 : Documentation of a risk assessment or an inspection that presumes there was lead based paint Notice of Lead hazard evaluation or presumption Evidence of abatement activities by qualified workers Clearance and notice of lead hazard reduction activities before re -occupancy If needed, Contractor will be responsible for obtaining a Certified Asbestos Inspection if asbestos is suspected during pre -bid walk-thru. Allowance for 2 storage PODs. 3,000.00 GRAND TOTAL 1 $.00 of CW* Construction Manager Seminole BCC Scope of Work Keith Welty/340 San Lanta Circle -Sanford, FL Revised: May 10, 2018 7/11/2018' Florida Building Code Online Business & Professional Regulation.Cltl'S i'' ' Wale W aCIS Home I Log In I User Registration I Hot TOPICS I Submit Surdharge I Slats & Facts I Publications I contact Us I aces Site Map I links I Search I Florida I,, Product Approval l''t1EE00®//'//USER: Public User Product Ap ajXR Menu > Product or APMiwtion Search > ep> Appllotlon Detail FL # FL11136-117 Application Type Revision Code Version 2017 Application Status Approved Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Certification Agency Validated By Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By JELD-WEN 3737 Lakeport Blvd Klamath Falls, OR 97601 800)535-3936 fbcl@jeld-wen.com Jason Kantola fbcl@jeld-wen.com JELD-WEN Corporate Customer Service 3737 Lakeport Blvd. Klamath Falls, OR 97601 800)535-3936 customerserviceagents@jeld-wen.com Exterior Doors Swinging Exterior Door Assemblies Certification Mark or Listing National Accreditation & Management Institute National Accreditation & Management Institute Standard TAS 201 TAS 202 TAS 203 YM 1994 1994 1994 Florida Licensed Professional Engineer or Architect FL11136 R7 Equiv ASTM E84 Eguivalency Letter SS 2017-08-31.pAf Product Approval Method Method 1 Option A htip://www.floridabuilding.orglpr/pr appdtl.aspx?param=wGEVXQwtDgttaGsip3Gvui5HdIONaDpDipd9QRNWgEgAkNpKzvDC89%3d%3d 1/4 7/11/2018 , Florida Building Code Online Date Submitted 10/26/2017 Date Validated 10/30/2017 Date Pending FBC Approval Date Approved 11/08/2017 Summary of Products FL !l I Model, Number or Name Description 11136.1 Contours Steel, Steel Edge 3'-0" x 6'-8", Opaque, Single Door, Inswing Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL11136 R7 C CAC NI011233-112.pdf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: Yes 08/31/2020 Design Pressure: +80/-80 Installation Instructions Other: FL11136 R7 II DC9970-1 Installation.odf Verified By: National Accreditation & Management Institute Created by Independent Third Party: Evaluation Reports FL11136 R7 AE PER3389.p_ff Created by Independent Third Party: Yes 11136.2 Contours Steel, Steel Edge 3'-0" x V-8", Opaque, Single Door, Outswing Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL11136 R7 C CAC NI011233-112&ff Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: Yes 08/31/2020 Design Pressure: +80/-80 Installation Instructions Other: FL11136 R7 II DC9970 Installation.odf Verified By: National Accreditation & Management Institute Created by Independent Third Party: Evaluation Reports FL11136 R7 AE PER3390.Rdf Created by Independent Third Party: Yes 11136.3 Contours Steel, Steel Edge 3'-0" x 8'-0", Opaque, Single Door, Inswing Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL11136 R7 C CAC NI011232-R2.p f Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: Yes 08/31/2020 Design Pressure: +61/-65 Installation Instructions Other: FL11136 R7 II DC9970-1 Installation.odj Verified By: National Accreditation & Management Institute Created by Independent Third Party: Evaluation Reports FL11136 R7 AE PER3389.ad Created by Independent Third Party: Yes 111136.4 1 Contours Steel, Steel Edge 1 3'-0" x 8'-0", Opaque, Single Door, Outswing Limits of Use Certification Agency Certificate Approved for use In HVHZ: Yes FL11136 R7 C CAC NI011232-R2.gdf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: Yes 08/31/2020 Design Pressure: +61/-65 Installation Instructions Other: FL11136 R7 II DC9970 Installation.odf Verified By: National Accreditation & Management Institute Created by Independent Third Party: Evaluation Reports FL11136 R7 AE PER3390.p_df Created by Independent Third Party: Yes 111136.5 1 Contours Steel, Steel Edge 1 3'-0" x 7'-0", Opaque, Single Door, Inswing I Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL11136 R7 C CAC NI011401-113.odf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: Yes 10/31/2026 Design Pressure: +66/-66 Installation Instructions Other: FL11136 R7 II A008267-FL Installation.pdf Verified By: National Accreditation & Management Institute Created by Independent Third Party: Evaluation Reports FL11136 R7 AE PER3399.pdf Created by Independent Third Party: Yes 11136.6 1 Contours Steel, Steel Edge Limits of Use Approved for use in HVHZ: Yes 3'-0" x 7'-0", Opaque, Single Door, Outswing Certification Agency Certificate FL11136 R7 C CAC NI011401.02-R3.odf http://vwvw.floridabuilding.orglprlpr app dtl.aspx?param=wGEVXQwtDgttaGsip3Gvui5HdtONaDpDipd9QRNWgEgAkNpKzvDC89%3d%3d 214 7/11/2018 Florida Building Code Online Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: Yes 10/31/2026 Design Pressure: +66/-66 Installation Instructions Other: FL11136 R7 II A008267-FL Installation.odf Verified By: National Accreditation & Management Institute Created by Independent Third Party: Evaluation Reports FL11136 R7 AE PER3399.Ddf Created by Independent Third Party: Yes 11136.7 Contours Steel, Steel Edge 3'-0' x 7'-0", Opaque, Single Door, Inswing Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL11136 R7 C CAC N1011401.01-R3.odf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: Yes 10/31/2026 Design Pressure: +47/-47 Installation Instructions Other: FL11136 R7 II A008267-FL Installation.Ddf Verified By: National Accreditation & Management Institute Created by Independent Third Party: Evaluation Reports FL11136 R7 AE PER3399.Rdf Created by Independent Third Party: Yes 11136.8 Contours Steel, Steel Edge 3'-0" x 7'-0", Opaque, Single Door, Outswing Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL11136 R7 C CAC NI011401.03-R3.12df Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: Yes 10/31/2026 Design Pressure: +47/-47 Installation Instructions Other: FL11136 R7 II A008267-FL Installation, pSlf Verified By: National Accreditation & Management Institute Created by Independent Third Party: Evaluation Reports FL11136 R7 AE PER3399.12df Created by Independent Third Party: Yes 11136.9 Contours Steel, Steel Edge 3'-0' x 7'-0", Opaque, Single Door, Inswing and Outswing Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL11136 R7 C CAC NI011573.03-116.2df Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: Yes 04/30/2026 Design Pressure: +70/-70 Installation Instructions Other: FL11136 R7 11 A009423 Installation.p d Verified By: National Accreditation & Management Institute Created by Independent Third Party: Evaluation Reports FL11136 R7 AE PER3400.p1Z Created by Independent Third Party: Yes 11136.10 Contours Steel, Steel Edge 3'-0' x 8'-0", Opaque, Single Door, Inswing and Outswing Limits of Use Certification Agency Certificate Approved for use In HVHZ: Yes FL11136 R7 C CAC N1011574.03-R6.12df Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: Yes 04/30/2026 Design Pressure: +55/-55 Installation Instructions Other: FL11136 R7 11 A009424 Installation.odf Verified By: National Accreditation & Management Institute Created by Independent Third Party: Evaluation Reports FL11136 R7 AE PER3401.odf Created by Independent Third Party: Yes cash Next Contact Us :: 2601 Blair Stone Road. Tallahassee FL 32399 Phone: 8SO-487-1824 I The State of Florida Is an AA/EEO employer. _gxdght 2007-2013 State of Florida.:: Privacy statement :: Accessibility Statement :: Refund Statement i Under Florida low, email addresses are public records. It you do not want your e-matl address released In response to a public -records request do not send electronic mall to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. -Pursuant to Section 455.275(t), Florida Statutes, effective October 1, 2012, licenseeslicensed underChapter 455, F.S. must provide the Departmentwith an email address ifthey have one. The emalls provided may be used for official communication with the licensee. Hovrever email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which on be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please dick h=. Product Approval Accepts: EN http://www.floridabuilding.org/pr/pr app dU.aspx?param=wGEVXQwtDgttaGslp3GvuiSHdtONaDpDipd9QRNWgEgAkNpKzvDC8g%3d%3d 3/4 JE ® Steel s STEEL. STEEL EDGE DOOR 6'-r 6 0'•0' SINGLE INSWING OPAQUE IMPACT DOOR 0 fA Y-1 7/4' Ow cc MAX. FRAME WIDTH coGENERALNOTESY-1 s/4' Ow , 3 wmrH ' (6h 1. THIS PRODUCT IS DESIGNED TO COMPLY WITH THE FLORIDA MAX FRAME WIDTHF Z O J CURRENTBUILDINGCODEINCLUDING 'HIGH VELOCITY s' ow HURRICANEZONE' (HVHZ) REOUIREMENTS. 3, 0 rnoTM a LV 2. WOOD BUCKS, BY BOTHERS, MUST BE ANCHORED PROPERLY IZ Y TOTRANSFERLOADSTOTHESTRUCTURE. 3. PRODUCT ANCHORS SHALL H AS EMBEDMENT AND SPACED F AS SHOWN ON DETAILS. ANCHOR EMBEDMENT 10 BASE MATERIALSHALLBEBEYONDWALLDRESSINGORSTUCCO. 4. IMPACT RESISTANT SHUTTERS NOT REQUIRED.LU 5. DESIGN PRESSURE RATING SHALL BE AS FOLLOWS: lq Y d FOR 6'8' WOOD FRAMES - SEE TABLE SHEET 1 _ FOR 8'0' WOOD FRAMES - SEE TABLE SHEET 1 8. THIS SYSTEM WAS TESTED FOR 2.86 LOS. WATER PRESSURE re ly ASPERASTM-E331. 7. THIS PRODUCT DOES NOT MEET THE WATER REOUIREMENTS C FOR ' HVH2'. l 27 i INSWING IMPACT STEEL EDGE DOOR Common Io e0 cams eadlbnsl 0 0 e o SCr $ 2 p DOOR LEAF CONSTRUCTION: $ e" $ ^L„° W Foee sheets: LW 24 go. (0.020') minimum thickness. Galvanized a S' V J Steel A-525 commercial quality - AKDO per ASTM 620 with 1T g o oe W Z Q 2 minimumaverageyieldstrengthFy.28,240 psi. W'nIX IX F 0Pere de•ion• Expanded polystyrene with 1.0 to 1.25 lbs. u n density, by JELD-WEN. 1 t. J mO b 40W W2 Panel Construction: Steel face sheets glued to expanded W ;s a polystyrene ( EPS). with steel top and bottom rails and steelstileswithawoodlockblockreinforcement. The ` hinge stile contains a MDF board for added hinge support. j o Gy.2p O 1-CW'.1Frame Conslruclian (Both Frame Types): The head jambs L71 e A and aids tombs are mortised, butted and joined using (3) 7/8' x 2 wire stoples. An aluminum adjustable inswing threshold woo uniti6zed of the sill. An optional aluminum ADA threshold is available. 6' 8" SINGLE /NSA/NC UN/T (X) 4'0- S/NCLB /NSW/NC UNIT (X) o NND a TABLE OF CONTENTS SCALE: 11Z' =f'-D' SCALE.- //Z' =f'-O" t SHT IF DESCRIPTION L Q 1 IYPICA E ATI NS & GENERAL NOTES ALL DOOR MODELS ARE VIEWED I ZO VERTICRSCT10NhBOLLFROMTHEINTERIORSIOE3 NOR( SS S C110N5 I 4 ANCHORING ING0 '' 3 COMPONENTS > r NOTE: PRODUCT HAS NOT BEEN RATED FOR% N N O O N WATERINFILTRATION. IF AUTHORITY HAVING o o L.,JURISDICTIONREOUIRESTHATPRODUCTMEETSoonmDESIGN PRESSURE RATING THIS REOUIREMENT, PRODUCT SHALL BE USED $ N ^ ^ ^ m o WHEN INSTALLED AT LOCATION PROTECTED BY OVERHANG S libi ill*, OVER (OH) RATIO WHERE rutEil oattlutwm AIDE WATER aDUM00N o o ^ o OH L`Y H,,}0(F%ISb1.0 mmvna^O HERMES F. NORERO DATE: 12 07 07 i4776OFLORIDAP.E. N0. 73778 fjNAI ; wLeAS NOTED 7 * = M Or EAG 61. Opsf-65.Opsf +61.Opsf S F r Emit. iwS. SAFFEL Z ORN? DRaealc 110.: Digitally signedby HermesF. Norero. P.E. ilcsS'•••••' erD G` •Aa0a OWLMe. DC9970-1 Reason: I am approving this document Date. 15.04.10 W..10:29 -00 0p irrr fON11111E%I. WAM Ft. map s¢EIFOR 0.0mko. 1 J- IIEOIs1E. 10a IS m1>mm ISOIrNE1 lf B Not NEEDED 80. Opsf-BO.Opsl +BO.Opsf-BO.Opsl m 2 1/2" MIN, c i EDGE DIST. 10 XX i+t m 3/4" MIN. gorsmipilom OlciEDGEDIST. Y ^ LATCH JAMB Q 1 4 B 18 PONDEROSA FINGER J0UlIED PINE P HINGE JAMB 0 1 4 4 B 18 PONEROSA FlNCER JOINTED PIN N O 7 31 \_ . , . •p• 32 HEAD JAMB 1 1 4 4 6 1e PONDERSOA FlNCER JCN PIN NE m 0 InnN3231 3 4 PFH WOOD SCREW WOOD I HI TO DOOR Z 0 -J T+j3aFi11WOODSCREWWTIH1.50 MIN. EMB. INTO SUB-BUCI( d N 3 e 3106 2 PM WOOD . . 09ENT 1 1 4 INTO MASON W Y= 0 AOA EXT. ALUMWUM THRESHOLD MODEL 5063-15 M. Q Q r 1 INSwWG ADJUST tE 1HRESHOlO 1.25 • 4.36 - Q, •^ SEE DETAIL A SEE DETAIL A COMPR THERSIMP LE ON ODS 630 -J ON SHEET 5 t3 18 ON SHEET 5 13 t 8 12 s PM wood SDREw Y a 1 9 1 PFF1 WOOD SCREW iACE SHEEP 24CA. .020 710t. MIN. CALVANRED STEELSITU 6 PFH WOOD 1 TOP RAIL 1.73 1.21 0.021 1HKt• `; 1 BOTTOM RA0. 1.73 1.21 0.021 1HK 26 20 SIDE SIRES 1.73 1.21 0.021 111K r:. :., 26 : :•.•+ WOOD LOCK BLOCK 1.67 3.0 18.75 16 16 K M gz_ a 'per 6 4 D „ Q 2 pp pp EKPANDED POLYSTYRENE 1.0 to 1.25 ID. DEN BY JELO-WEN CIO < p Q I N • 1 p O 2 KWIKSET 79AN SERIES LATCH h DEADBOLT 200 k 660 1 'O.1 C `;V '• a10 OI .. 1 1 ~•. •^. I 1 a KWIKSET TITAN SCR IES LATCH 6 DEADBOLT 700 - W J wC v 1 .. t •.0.. rA vm LATCH SCREWS a 1 12 M wooD SCREW C C5 1... F 30 NOT USED LU V ti 15 = 9_ V tE 3 1K MAK. COMPRESSION SHIM W O-> W W_ W_ W W W 16 CA. 7 16 CROWN 2 LONG ST IW- 1 UO W (. 7 2 i W W 22 rjj. m W W= J J W W W-1 O W" m v bpCDcoIfuDM 10,10 CIO m t4 to mo 10 JIB 22 24 26 26 i_ d to q 0 La 0 19 w 19 vm 9 I`I`N N m c 24 w 2 1/2" MIN. P, 0 0 0 W 24 EDGE DIST. N'= m a Z ODNh' 0 00 O'• IL 11 11 CONCRETES AVERTICALLE: 3" =1'-O" m u1 v n N Za 31 ` ; G N§ :? Q HERMES F. NORERO aye 12 07 07 r/N 7 7 FLORIDA P.E. N0. 73778 SCAU AS NOTED 3/4" MIN. 7 2 1/2" MIN. = * * r m BY: EAG EDGE DIST. EDGE DIST. g : v . ?TA/T OF o eNIL eY 5. SAFFEL 0*'" -'$i O,R1UP ."' 4- GRAW04 NO.: 9VERTICAL CROSS SArTION TYP 9 s'S10NAl E' 3"rAST 6waDO'siuo iLWI DC9970-1 2 WOOD FRARE INSTALLATION SCALE 3" =1'-O" 2 CONCRETE INSTALLATION SCALE' 3" =1'-0" 0 ,YYYTTT 111117LW. tt.oA IL 3=4 SNEET 2 a 5 37 3/4- MAX. FRAME WIDTH G10 36' MAX PANEL WIDTH 32 31 22 4 > CC 21 25 26 1 C) 5 ED 20 23 Q (r z C? 2 U. CY 2 16 SEE OEIAIL 7 6 EXTERIO ON SHEET 5 Uj 1, 3f 27 1/4' MAX. SHIM 2 1 1/4- SPACE 1 1/2- MIN. EMB. 1 1/2' MIN. EMB. L JV0RlZQ)ffAL CBOSS M== TYP, 3 IVOOP INSTALLATION SCALE: 3" -/'-0" cr a. z L610 Q- V) RZU Ln d. 37 3/4- MAX. FRAME WIDTH 38' MAX PANEL VADTH L) 36* MAX PANEL WIDTH32 of -co Z31032a1113 64 C, 21 25 1,@26.1 INTERIOR 5 00 V) CO at20Ix 23 1 0 0130 ILI1313 003n27 j 2 1/2- MIN. SEE DE7,AlL A 16 26 81/jj 2 2* MIN. an an an 1311 mom men EDGE DIET. ON SHEET 5 EXTERIO EDGE DIET. 2 u 1/4- MAX. SHIM IQSPACE — cm x 1 1/4* —1 1/4* 1/4- an 00 mom gigMIN. EMB. MIN. EMB. u BORLWATAL CROSS SMM& TYP, 3 CONCRETE INSTALLATION SCALE: 3" -/'-0" c.S F. I , :,/ 7 /... u - 7'i FLORIDA P.E. NO. 73778 SOUL- AS NOTED DWG. ft. EAG I W-TAAI OF : T ,E CRL Ims. SAFFE C, DRAWING NO, 4,- % 9/ONAL orm w- DC9970-1MK%MEMWM arLw" KV& K4M3MnotCerOMIN "N.Amm, ft MU SHM or Is.—[ IB" 9 15 16' I 91516' co to1, coI N 9 15 16' v 9 15 16' 9 15 16' 9 15M16- A 9 15 8 9/16' 8 9/16" SEE DETAIL D I I _ 7 9 io Map. n r, CD I M 7 9 \ TW in DETAIL B - A 7 9 B 6"--IP 6" SEE DETAIL C ANCHORING LOCATIONS 6'8•' INSWING SINGLE UNIT (X) SCALE: 11Z' -1'-0" SEE DETAIL A I. 6" 1'-0 5%1K 1'-A%16• 1'-0 3%16• L 1'-0 %1 1'-0 3%16- 6=-1 fi -{ j SEE DETAIL D I M/,--SEE DETAIL A 8 3/4" II II II 1 _,,- Typ-- 7 9 SEE DETAIL B J 7 9 - C ]72. 6t- iAAC6' NS 8' 0" INSWIN SIN LENIT (XJ SCALE: 1/2' =1'-O" DETAIL C DETAIL D SCALE: 3" =1'-0" SCALE` 3" =1'-O" M F. 2' 2' SEE DETAIL C i V 7 FLORIDA P.E. NO. 73778 MAU: AS NOTED t * = owc er EAG 4% E 9P ,btu cm& er.S. SAFFELL OR10 , wl," own, et DPAWM NO.. DC9970- 1 0111111`,, KCH WOOketFtUMsmm 4 OF 5 4" O n 3/4" o[ MggE; f- 2 3/16" -) Z O Q 1 /2" a U. NI--1/16" (Min) T— 4 9/16" --I W Y 2: c? 1 Q 10 1 Ti/RESHOLD 11 /SA/NC TfIR6SHOLD LU ^ g = SCALE.- 6" =f'-0" SCALE:• 6" =f'-O" Y a Z 3 9/16" 1 3/4" og 1 3/4" b ? 1_L 1 3/16" W11/4" — 7 W v—i~ a13/16" 1 1/8" W 6 a„ ipWEU W DOOR TOP RAIL & SIDE STILE W 41a 7 j ,CO=PRESS/OA+ AML- RSTRIP i ov STEEL 19 BOTTOA/ RA/L 23 ' 1 0 SCALE.E6" =1'-O" SCALB 6" =f'-0" SCALE? 6" e1'-0" SCALE 6" =1'-O" .I v 1 I 0 VINYL BOT91D= DOOR SAEEP SCALE• 6" =f'-O" 18' for 8'-0" DOOR 11 3//a4" FOR 6'-8" DOOR 1I/ 4" 0 J W. VARIES WITH HARDWARE USED @@= SCA&L,6=3j" =1'-0" 1 23/32" 1 3/ 16" C-SINK. — DETA/ L A SCALE- 1/4" =1'-O" E u too,, v v v F. tiG N'• P' O HERMES F. NORERO FLORIDA P.E. N0. 73778SCALE W E:12 07 07 AS NOTED IgVOr FAG pS%TE OP aac. er.S. SAFFE Or. nen 8/7/2018 Florida Building Code Online usiness & Professional Regulationsly C r, SOS Home 1 Log In 1 User Registration I Hot Topics Submit Surcharge I Stats tl Facts Publications Contact Us SCIS Site Map Links search FI rich r Product Approval a USER: Public Userd . Product Aooroval Menu > Product or Aooiication Search > ApoliWtion Ust > Application Detail FL # FL26012 Application Type New Code Version 2017 Application Status Approved Approved by DBPR. Approvals by DBPR shall be reviewed and ratified bythePOCand/or the Commission if necessary. Comments Archived Product Manufacturer MI Windows and Doors Address/Phone/Email 650 West Market Street Gratz, PA 17030 717)365-3300 Ext2560 bsitlinger@miwd.com Authorized Signature Brent Sitlinger bsitlinger@miwd.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Exterior Doors Subcategory Sliding Exterior Door Assemblies Compliance Method Certification Mark or Listing Certification Agency American Architectural Manufacturers Association Validated By Steven M. Urich, PE d Validation Checklist - Hardcopy Received Referenced Standard and Year (of Standard) Standard Year AAMA 506 2011 AAMA/WDMA/CSA 101/I.S.2/A440 2011 AAMA/WDMA/CSA 101/I.S.2/A440 2008 Equivalence of Product Standards Certified By Product Approval Method Method 1 Option A Date Submitted 02/05/2018 Date Validated 02/06/2018 Date Pending FBC Approval http://www.floridabuilding.org/prIpr app 00.aspx?param=wGEVXQwtDgsH88r2%2fJKYUokQHKbl2T9%2fHJReS6QDv4VLDrLN%2fGEzKQ%3d%3d 1/3 8n/2018 Date Approved Florida Building Code Online 02/10/2018 Summary of Products FL # Model, Number or Name Description 26012.1 1615/1617 SGD 14096 w/Insulated Laminated Glass Limits of Use Certification Agency Certificate i Approved for use in HVHZ: No FL26012 Ro C CAC AP (16613)H0o79.01-109-47-R1 1615- Approved for use outside HVHZ: Yes 1617 SGD( 401722),pd Impact Resistant: No Quality Assurance Contract Expiration DateDesignPressure: +50/-50 04/17/2022 Other: LC-PG50 Installation Instructions FL26012 RO 11 08-03131A.odf Verified By: Luis R. Lomas, PE PE-62514 Created by Independent Third Party: Yes Evaluation Reports FL26012 RO AE 514040A 3131pd Created by Independent Third Party: Yes 26012. 2 1615/1617 SGD 106x96 Insulated Glass Limits of Use Certification Agency Certificate ApprovedforuseinHVHZ: No FL26012 RO C CAC APC(16245)AI-04220-A1 1615-1617 Approved for use outside HVHZ: Yes SGD(050519),pdf Impact Resistant: No Quality Assurance Contract Expiration Date Design Pressure: +40/-40 05/05/2019 Other: R-PG40 Installation Instructions FL26012 RO II 08-03132A.I?d Verified By: Luis R. Lomas, PE PE-62514 Created by Independent Third Party: Yes Evaluation Reports FL26012 RO AE 514041A 3 32.pd Created by Independent Third Party. Yes 26012. 3 1615/1617 SGD 71x82 Insulated Laminated Glass Limits of Use Certification Agency Certificate Approved for use In HVHZ: No FL26012 RO C CAC APC(16465)AI-03810-V1-R3 1615-1617 Approved for use outside HVHZ: Yes 5M(091520),pda ImpactResistant: No Quality Assurance Contract Expiration Date DesignPressure: 60/-60 09/15/2020 Other: R-PG60 Installation Instructions FL26012 RO II 08-03129A odf Verified By: Luis R. Lomas, PE PE-62514 Created by Independent Third Party: Yes Evaluation Reports FL26012 RO AE 514038A 3129.odf Created by Independent Third Party: Yes 26012. 4 1615/1617 SGD 187x80 Insulated Glass Limits of Use Approvedlforuse in HVHZ: No Certification Agency Certificate FL26012 RO C CAC APC(16607)G7944.01-109-47-RO 1615- Approved Ifor use outside HVHZ: Yes 1617 5GD(030922),p j ImpactResistant: No Quality Assurance Contract Expiration Date DesignPressure: +20/-20 03/09/2022 Other: R-PG20 Installation Instructions FL26012 RO II 08-03133A.pdf Verified By: Luis R. Lomas, PE PE-62514 Created by Independent Third Party: Yes Evaluation Reports FL26012 RO AE 514042A 3133 odf Created by Independent Third Party: Yes 26012. 5 I 1615/1617 SGD 144x96 Insulated Laminated Glass, Impact Limits of Use Certification Agency Certificate ApprovedforuseinHVHZ: No FL26012 R0 C CAC APC(16612)H0079.02-109-47-R1 1615- Approved for use outside HVHZ: Yes 1617 5GW041322),Rd ImpactResistant: Yes Quality Assurance Contract Expiration Date DesignPressure: +50/-50 04/13/2022 Other: LC-PG50, Missile Level D, Wind Zone 3 Installation Instructions FL26012 RO II 08-03127A odf Verified By: Luis R. Lomas, PE PE-62514 Created by Independent Third Party: Yes Evaluation Reports FL26012 RO AE 514036A 3127 edf Created by Independent Third Party: Yes 26012. E I 1615/1617 SGD 96x96 Insulated Glass Limits of Use Certification Agency Certificate http:/ Avww.floridabuilding.org/pr/pr app dU.aspx?param--wGEVXQwtDgsH88r2%2fJKYUokQHKbl2T9%2fHjReS6QDv4VLDrLN%2fGEzKQ%3d%3d 2/3 8f7/2018 Florida Building Code Online Approved for use In HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-50 Other: LC-PG50 FL26012 RO C CAC MI Windows - 1615-1617 Scan Ila Jan. 2 ILP- if Quality Assurance Contract Expiration Date 03/23/2022 Installation Instructions FL26012 RO II 08-03130A pdf Verified By: Luis R. Lomas, PE PE-62514 Created by Independent Third Party: Yes Evaluation Reports FL26012 RO AE S14039A 3130 r,rlf Created by Independent Third Party: Yes Sic:: Next Contact Us :: 2601 Blair Stone Road. Tbllahassee Fl. vovoo Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copvriaht 2007-2013 State of Florida :: Prhmcv Statement :: ArMslbility Statement :: Re Under Florida law, email addresses are public records. If you do not want your e-mail address released In response to a public -records request, do not send electronicmalltothisentity. Instead, contact the office by phone or by traditional mall. If you have any questions, Please contact 850.487.1395. -Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address If they have one. The emailsprovidedmaybeusedforofficialcommunicationwiththelicensee. However email addresses are public record. If you do not wish to supply a personal address, pleaseprovidetheDepartmentwithanemailaddresswhichcanbemadeavailabletothepublicTodetermineifyouarealicenseeunderChapter455, F.S., please click here . Product Approval Accepts: Tr. U RM ¢rxr MEN Credit Card Safe http://www.floridabuilding.org/pr/pr app dll.aspx?param=wGEVXQwtDgsH88r2%2fJKYUokQHKb12T9%2fHJReS6QDv4VLDrLN%2fGEzKQ%3d%3d 3/3 NOTES: 1 THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH REQUIREMENTS OF THE FLORIDA BUILDING CODE. 2. WOOD FRAMING AND MASONRY OPENING TO BE DESIGNED AND ANCHORED TO PROPERLY TRANSFER ALL LOADS TO STRUCTURE. FRAMING AND MASONRY OPENING IS THE RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. 3. IX BUCK OVER MASONRY/CONCRETE IS OPTIONAL. 4. WHERE SHIM OR BUCK THICKNESS IS LESS THAN 1-1/2" WINDOW UNITS MUST BE ANCHORED THROUGH THE FRAME IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS. ANCHORS SHALL BE SECURELY FASTENED DIRECTLY INTO MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE MATERIAL. 5. WHERE WOOD BUCK THICKNESS IS 1-1/2' OR GREATER, BUCK SHALL BE SECURELY FASTENED TO MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE. WINDOW UNITS MAY BE ANCHORED THROUGH FRAME TO SECURED WOOD BUCK IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS. 6. WHERE 1X BUCK IS NOT USED DISSIMILAR MATERIALS MUST BE SEPARATED WITH APPROVED COATING OR MEMBRANE. SELECTION OF COATING OR MEMBRANE IS THE RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. 7. BUCKS SHALL EXTEND BEYOND WINDOW INTERIOR FACE SO THAT FULL FRAME SUPPORT IS PROVIDED. 8. FOR FIN INSTALLATION SHIM AS NEEDED. FOR FRAME INSTALLATION SHIM AS REOUIREO AT EACH ANCHOR LOCATION WITH LOAD BEARING SHIM. SHIM WHERE SPACE OF 1/16" OR GREATER OCCURS. MAXIMUM ALLOWABLE SHIM STACK TO BE 1/4' 9. SHIMS SHALL BE LOCATED, APPLIED AND MADE FROM MATERIALS AND THICKNESS CAPABLE OF SUSTAINING APPLICABLE LOADS. 10. WIND LOAD DURATION FACTOR Cd-1.6 WAS USED FOR WOOD ANCHOR CALCULATIONS. 11. FRAME MATERIAL: EXTRUDED RIGID PVC. 12. UNITS MUST BE GLAZED PER ASTM E1300-04/09, WITH SAFETY GLAZING. 13. APPROVED IMPACT PROTECTIVE SYSTEM IS REQUIRED FOR THIS PRODUCT IN WIND BORNE DEBRIS REGIONS. 14. FOR ANCHORING THROUGH FRAME INTO WOOD FRAMING OR 2X BUCK USE #12 WOOD SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 3/8' MINIMUM EMBEDMENT INTO SUBSTRATE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. TABLE OF CONTENTS SHEET NO. DESCRIPTION 1 NOTES 2 ELEVATION AND GLASS DETAIL 3 - 6 INSTALLATION DETAILS REV I DESCRIPTION CATE I APPROVED A I ADDED SILL INSTALLATIONS 01/11/18 1 R.L. 15.FOR ANCHORING THROUGH FRAME INTO MASONRY/CONCRETE USE 1/4" ELCO ULTRACON TAPCONS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE WITH I" MINIMUM EDGE DISTANCE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. 16. FOR ANCHORING THROUGH FRAME INTO METAL STRUCTURE USE #12 SMS OR SELF DRILLING SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE 3 THREADS MINIMUM BEYOND STRUCTURE INTERIOR WALL. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS 17. FOR ANCHORING THROUGH CLIP INTO WOOD FRAMING OR 2X BUCK USE N8 WOOD SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. 18. FOR ANCHORING THROUGH CLIP INTO MASONRY/CONCRETE USE 1/4" ELCO ULTRACON TAPCONS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE WITH 1" MINIMUM EDGE DISTANCE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. 19. FOR ANCHORING THROUGH CLIP INTO METAL STRUCTURE USE 18 SMS OR SELF DRILLING SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE 3 THREADS MINIMUM BEYOND STRUCTURE INTERIOR WALL. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. 20. ALL FASTENERS TO BE CORROSION RESISTANT. 21. INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BELOW: A. WOOD: MINIMUM SPECIFIC GRAVITY OF G-0.42 B. CONCRETE: MINIMUM COMPRESSIVE STRENGTH OF 2.000 PSI. C. MASONRY: HOLLOW/FILLED BLOCK PER ASTM C90 WITH Fm-2,000PSI MINIMUM. D. METAL STRUCTURE: STEEL 18GA (.048") FY=33KSI/FU=52KS1 OR ALUMINUM 6063-T5 FU=30KSI 060" THICK MINIMUM 22. APPROVED CONFIGURATIONS: XO, OX SIGNED: 01/1112018 MI WINDOWS & DOORS LLC. uul rq 650 WEST REET GRTZ, MPAK17030ET J S`CEN,S Z*• I0 5 *= SERIES 1615/1617 PVC SLIDING GLASS DOOR NON -IMPACT XO o GaENOTESD • TAT OF OAF 0R10P• DRAWN: OK NO. REV OB 9 A II aG` LUIS R. Lomas P.E. sulE NTS aTE 06/2-- 7 -ET 1 OF 6 L ROBERTO LOMAS P.E. IIJ2WOWFORO RO LEWISVRLE, MC270M p&U4804dm p,mm FL No.: 62514 81 1 FE HE 4.. MW V //a MAX FRAME WIDTH r r--r 12" MAX O.C. -• 4 MAX 12" MAX O.C. 7/8" IAX XAMEQ GHIGHi L 4 MAX C* 1 4" MAX 1) ANCHOR PER LOCATION SEE CHART #1 FOR NUMBER OF ANCHOR LOCATIONS REQUIRED SERIES 161511617 PVC SLIDING GLASS DOOR NON -- IMPACT ANCHORSTOBEINSTATA SILLLLED EXTERIOR VIEW THROUGH ANCHOR CLIPUPTOPANEL0ONFIOURA77ONSAREQUALIFIED AS LONGASPANEL AREA DOESNOTEXCEED 19.3F77, SEENOTE 22 DESIGN PRESSURE RATING IMPACTRATING t60.OPSF NONE HARDWARE SCHEDULE HANDLE (9748) 1 POINTMORTISE LOCKWITH KEEPER (9149) 2 POINT MORTISE LOCK WITH KEEPERS (9249) ROLLERS (9732) EEL REINFORCEMENT (9599) AT MEETING STILES EEL REINFORCEMENT (9598) ATLOCKING STILES REVISIONS REV I OESCRIPTION 011E I APPROVED A I ADOED SILL INSTALLATIONS 01/11/16 1 R.L. NOTES: 1. MAXIMUM PANEL SIZE: 35 S18' x 779116' 2. MAXIMUM D.LO.: 293/16' x7171I6' CHART a1 Numberofanchor locationsrequired Fame eight in) Fame Width n 36.00 H IS S Jamb 48.00 N d S Jamb 8100 H a S Jamb 1 70.88 H IS S Jamb 81.88 4 8 5 8 1 7 1 8 1 e 1 6 3 3/16" 1 i/8" 1/12' O®O o O 16" T J_ L 1/4" CLIP GALVANIZED STEEL (.051- THICKJ MI WINDOWS & DOORS, LLC. 650 WEST MARKET STREET GRATZ, PA 17030 SERIES 1615/1617 PVC SLIDING GLASS DOOR NON — IMPACT XO ELEVATION AND GLASS DETAIL A.R. 1 08-03129 w'E NTS I-E 06/28/17 _S"Efl2 OF 6 L. ROBERTO COMMIS AE 14M WOWFOR0 REPLEWISVW, NC 27M 434.6664609 Nbm&S&b,Imsp&=m SIGNED: 0111112018 A0;.4TAAT0 OF 01YA11 aG`` Luis R. Lomas P.E. FL No.: 62514 WOOD FRAMING OR 2X BUCK BY OTHERS BACKER ROD do APPROVED SEALANT EXTERIOR BACKER ROD do APPROVED SEALANT WOOD FRAMING OR 2X BUCK BY OTHERS 1/2" MIN EDGE DISTANCE r VERTICAL CROSS SECTION WOOD FRAMING OR 2X BUCK INSTALLATION 1 MIN EMBEDMENT 1/4" MIN SHIM SPACE 12 WOOD SCREW INTERIOR 1 3/8" MIN EMBEDMENT 1/2" MIN EDGE DISTANCE 12 WOOD SCREW WOOD FRAMING OR 2X BUCK BY OTHERS RENSIONS REV DESCRIPTION DATE APPROVED A ADDED SILL INSTALLATIONS 01/11/18 R.L. 1/4" MINrSHIMSPACE INTERIOR EXTERIOR BACKER ROD do APPROVED SEALANT JAMB INSTALLATION DETAIL WOOD FRAMING OR2XBUCKINSTALLATION ANCHOR CLIP d8 WOOD SCREW NOTES: 1. INTERIOR AND EXTERIOR FINISHES. BY OTHERS NOT SHOWN FOR CLARITY. 1 /4" MAX 2. PERIMETER ANDJOINTSEALANT BY OTHERS TO BE SHIM SPACE DESIGNED WACCORDANCEWITHASTME2112 I SIGNED. 01/1112018 1 1/4" MIN MI WINDOWS & DOORS, LLC. EMBEDMENT 650 WEST 0%II11I/a// vJ SSP i GRATZ, MPAKE7030REET 1/2" MIN SERIES 1615/1617 PVC SLIDING GLASS DOOR NON — IMPACT XO f *• 0 5 * = EDGE DISTANCE INSTALLATION DETAILS tROTATE OF'.,-` oaAwN• A.R. owc No. aLv i'Fs;°[ORIO; GN'`. 08-03129 A NTS O'1E 06/28/17 1SNEE13 OF 6 L ROBERTO LOMAS P.E. 14= MR700FORDROLEWISVILLE. AC 2MM LUIS R. Lomas P.E. IJ481.0609 /0A1ataWmaw.00m FL No.: 62514 METAL STRUCTURE BY OTHERS BACKER ROD do APPROVED SEALANT BACKER ROO APPROVED SEALANT METAL STRUCTURE BY OTHERS 1/2" MIN I EDGE DISTANCE r 1/4" MIN SHIM SPACE 12 SMS OR SELF DRILLIGN SCREW EXTERIOR INTERIOR VERTICAL CROSS SECTION METAL STRUCTUREINSTALLATM NCHOR CLIP N8 SMS OR SELF DRILLING SCREW 1/4" MAX I- SHIM SPACE E1 1 /2" MIN EDGE DISTANCE I 1/2" MIN EDGE DISTANC 1T 12 SMS OR SELF DRILLING SCREW METAL STRUCTURE BY OTHERS REVISIONS REV DESCRIPTION DATE APPRMW A I ADOEO SILL INSTALLATIONS 01/11/18 1 R.L. 1/4" MINrSHIMSPACE do APPROVED SEALANT JAMB INSTALLATION DETAIL METAL STRUCTURE INSTALLATION NOTES: I. INTERIOR AND EXTERIOR FINISHES, BY OTHERS, NOT SHOWN FOR CLARITY. 2. PERIMETER ANDJOINT SEALANT BYOTHERS TO BE DESIGNED IN ACCORDANCE KIM ASTM E2112 MI WINDOWS & DOORS, LLC. 650 WEST MARKET STREET GRATZ, PA 17030 SERIES 1615/1617 PVC SLIDING GLASS DOOR NON - IMPACT XO INSTALLATION DETAILS DRAW ONG NO. A.R. 08-03129 slut NTS o+rE 06/28/17 —R4 OF 6 L ROSERTO LOMAS P.E. T172 WOWFORD RO LEWISVIUS, AC DOPE IJ -MO-0601 Abmaf®Obmavemm ERIOR RIOR SIGNED: O1/1112018 vGENs'4s.i oA.8126 •• * = A* TTAftT irrE OF ; P O0R1,0 G\ v\ LuisR. Lomas P. E. FL No.: 62514 I. MIN LEDGE DISTANCE CONCRETE/ , MASONRY BY OTHERS ••' ° ° 1 1/4" MIN EMBEDMENT 1 I OPTIONAL 1X BUCK SEE NOTES 3-7 1/a" MINSHEET1SHIMSPACE 0 O C3 BACKER R00 APPROVED SEALANT 1/4" ELCO ULTRACON00f _ _ TAPCON EXTERIOA INTERIOR REV15WNs REV OESCRIPNpn A ADDEO SILL INSTALLATIONS 1 1/4" MIN 1/4 MIN EMBEDMENT SHIM SPACE I" v MIN , EDGE DISTANCE p 1/4" ELCO ULTRACON TAPCON v CONCRETE/ MASONRY v BY OTHERS OPTIONAL 1 X BUCK SEE NOTES 3-7 SHEET 1 BACKER ROD APPROVED SEALANT JAMB INSTALLATION DETAIL CONCRETEMASONRYINSTALLATION DATE I APPROVED 01/11/18 JR,L. INTERIOR EXTERIOR UI I U I I ANCHOR CLIP BACKER ROD 0 U1/4" ELCO ULTRACON NOTES: do APPROVED TAPCON 1. INTERIOR ANDEXTERIOR FINISHES, BY OTHERS, SEALANT DO NOT SHOWNFOR CL4RITY. p O 2. PERIMETER ANDJOINT SEALANTBYOTHERSTO BEO 1/4_ MAX DESIGNED IN ACCORDANCE WITH ASTM E2112 OPTIONAL 1X BUCK SIGNED: 17ill 1rh7113SEE NOTES 3-7 SHIM SPACE SHEET 1 MI WINDOWS & DOORS, LLC. 0111111111// 650 WEST MARKET STREET \\\\S;Z'.:0 1j i GRATZ. PA 17030 `v .-pENs. 94p COMASONRY NCRETE/ ISERIES 1615 1617 PVC SLIDING GLASS DOOR * 0 HERS ° °• , ° 1 1/4" MIN / _ 9AT 6°EMBEDMENT NON — IMPACT XO°i • INSTALLATIONDETAILS rA. N: OMO NO. REV 'OF •'O4ORIQP• t" MIN NTS°" O6/28/17 08L'S9 OF 6 A i sjONA"EaG` VERTICAL CROSSSECTIONEDGEMINCONCRETEMASONRYINS TALLATION LROBERTOLOAUSP.ELuis R. Lomas P.E. 1432 WOODFORD ROLEWISVILLE. NC 270M4N-680FL No.: 62514 Os09 Nbmes b+bnw>ar.rnm Allk BACKER ROD Qc APPROVED SEALANT 300 FRAMING OR 2X BUCK BY OTHERS' BACKER ROD APPROVED SEALANT METAL STRUCTURE BY OTHERS i EXTERIOR 1/2" MIN EDGE DISTANCE VERTICAL CROSS SECTION WOOD FRAMING OR 2X BUCK INSTALLATION 1/2" MIN EDGE DISTANCE VERTICAL CROSS SECTION METAL STRUCTURE INSTALLATION REVISIONS REV OEWRIPRON DATE APPROVED OPTIONAL SILL INSTALLATIONS A ADDEO SILL INSTALLATIONS 01/11/18 R.L. 12 WOOD SCREW 1/4" MAX SHIM SPACE 4w MIN EMBEDMENT 12 SMS OR SELF DRILLING SCREW 1/4- MAX SHIM SPACE BACKER ROD k APPROVED SEALANT OPTIONAL 1X BUCK SEE NOTES 3-7 SHEET 1 CONCRETE/ MASONRY BY OTHERS ICI 1 1!!J 1/4" ELCO ULTRACON TAPCON 1. / U- r 1/4" MAX L/r U SHIM SPACE 1 1/4" MIN 4. EMBEDMENT E 1" MIN EDGE DISTANCE L VERTICAL CROSS SECTION CONCRETE MASONRY INSTALLATION NOTES: 1. INTERIOR AND EXTERIOR FINISHES, BYOTHERA NOT SHOWN FOR CLARITY. 2. PERIMETER AND JOINT SEALANT BYOTHERS TOBE DESIGNED IN ACCOROANCE WITH ASTME2112 MI WINDOWS & DOORS, LLC. 650 WEST MARKET STREET GRATZ, PA 17030 SERIES 1615/1617 PVC SLIDING GLASS DOOR NON — IMPACT XO INSTALLATION DETAILS DRAWN: OWG N0. A.R. 08-03129 x NTS WE06/28/17 1s"EEl6 OF 6 L. ROBERTO LOMAS AE 14-V w?ODFORO RD LEMWLLE MC 27M 4-u-s xos &vw*&ftnwfxcM SIGNED: ow1P2we 0%11t 11L GEN'? TAT 5 ••*= AQ OF • C i'.• Lneltl•. ;14J IIIIIIIT`' Luls R. Lomas P.E. FL No.: 62514 Florida Building Code Online http://www.floridabuilding.org/pr/pr app dtl.aspx?param=WGEVXQ... IL 11E Business Professional Regulation, BCIS Home log in : User Registration Hot Topics Submit Surcharge Stats & Facts PubrcatiDns FBC Stair SCIS Site Map Urft Search bPr Product Approval I: USER: Public User I.QlKt9DR9Yd! MerJ1 > lio utt_grRap_k;it n - ar i > Arnim !9n Lst > Appaotlon Detall FL # FL15217-R5 Application Type Revision Code Version 2017 Application Status Approved Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Florida Engineer or Architect Name who developed the Evaluation Report Florida License Quality Assurance Entity Quality Assurance Contract Expiration Date Validated By Certificate of independence Referenced Standard and Year (of Standard) MI Windows and Doors 650 West Market Street Gratz, PA 17030 717)365-3300 Ext2560 bsitlinger@miwd.com Brent Sitlinger bsitlinger@miwd.com Windows Single Hung Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Luis Roberto Lomas PE-62514 National Accreditation and Management Institute 12/31/2018 Steven M. Urich, PE Validation Checklist - Hardcopy Received FL15217 RS COI FLCOI.Pddf Standard AAMA/WDMA/CSA 101/I.S.2/A440 AAMA/WDMA/CSA 101/z.S.2/A440 ASTM E1886 ASTM E1996 ASTM E330 Year 2005 2008 2005 2005 2002 1 of 5 4/ 17/2018, 8:57 AM r Florida Building Code Online http://www.floridabuilding.org/pr/pr app_dtl.aspx?parwn=wGEVXQ... Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Date Submitted Date Validated Date,Pending FBC Approval Date Approved Summary of Products Go to Page 0 Method 1 Option D 12/31/2017 12/31/2017 01/04/2018 0 Page 1 / 2' FL # i Model, Number or Name i Description SERIES SS00 PVC SH TWIN NI CONTINUOUS HEAD AND SILL115217.1 I SERIES 5500 PVC SH 84x84 1 Limits of Use I Installation Instructions I Approved for use in HVHZ: No FL15217 RS 11 08-0j9286.pdf Approved for use outside HVHZ: Yes Verified By: Luis Roberto Lomas 62514 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: REFER TO APPROVAL DOCUMENT FOR DESIGN FL15217 R5 AE 512636A.odf PRESSURE RATINGS. Created by Independent Third Party: YesL 15217.2 SERIES 5500 PVC SH SERIES 5500 PVC SH NI 42X84 i Installation InstructionsLimitsofUse — — Approved for use in HVHZ: No FL15217 R5 II 08-01927A.pdf Approved for use outside HVHZ: Yes Verified By: Luis Roberto Lomas 62514 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: REFER TO APPROVAL DOCUMENT FOR DESIGN FLIS217 R5 AE 512625A.pdf PRESSURE RATINGS. Created by Independent Third Party: Yes j 15217.3 i SERIES 5500 PVC SH SERIES 5500 PVC SH NI 48X72 Limits of Use Installation Instructions Approved for use in HVHZ: No FLIS217 R5 11 08-02719.pdf Approved for use outside HVHZ: Yes I Verified By: Luis Roberto Lomas 62514ImpactResistant: No Created by Independent Third Party: Yes I Design Pressure: N/A Other: REFER TO APPROVAL DOCUMENT FOR DESIGN Evaluation Reports FL15217 R5 AE 5135.0 PRESSURE RATINGS. _ — ---` —'1 j. Created by Independent Third Party: Yes SERIES GA 195 ALUMINUM SH NI 44X841115217.4 SERIES GA 195 ALUMINUM SH — Limits of Use Installation Instructions i Approved for use in HVHZ: No I FLIS217 R5 II 08-00261E.p Approved for use outside HVHZ: Yes FLIS217 R5 II 08-00262E.pdf Impact Resistant: No Verified By: Luis Roberto Lomas 62514 Design Pressure: N/A j Created by Independent Third Party: Yes Other: REFER TO APPROVAL DOCUMENT FOR DESIGN Evaluation Reports PRESSURE RATINGS FL15217 R5 AE 510338C.pdf If Created by Independent Third Party: Yes SERIES GA 195 ALUMINUM SH NJ 54X7215217.5 1 SERIES GA 195 ALUMINUM SH ' Limits of Use Installation Instructions Approved for use in HVHZ:'No FL15217 R5 II 08-01331B.pddf Approved for use outside HVHZ: Yes Verified By: Luis Roberto Lomas 62S14 i Impact Resistant: No I Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: REFER TO APPROVAL DOCUMENT FOR DESIGN FLIS217 RS AE 511943C.odf I PRESSURE RATINGS Created by Independent Third Party: Yes 15217.6 1 SERIES GA 195 ALUMINUM SH SERIES GA 19S ALUMINUM SH NI 44X84 2 of 5 4/17/2018, 8:57 AM Florida Building Code Online http://www. loridabuilding.org/pr/pr app_dti.aspx?param=wGEVXQ... Limits of Use I Installation Instructions I Approved for use in HVHZ: No FLIS217 R5 11 08.00265E.pdf I Approved for use outside HVHZ: Yes FL15217 R5 11 08-00266E.Ddf iImpactResistant: No 1 Verified By: Luis Roberto Lomas 62514 Design Pressure: N/A Created by Independent Third Party: Yes I Other: REFER TO APPROVAL DOCUMENT FOR DESIGN Evaluation ReportsIPRESSURERATINGS. FL15217 R5 AE 510340D.Ddf ! Created by Independent Third Party: Yes 15217_7 1 SERIES GA 195 ALUMINUM SH SERIES GA 195 ALUMINUM SH NI 54X72 Y---- of Use Installation InstructionsiLimitsApprovedforuseinHVHZ: No FLIS217 R5 II 08-01217B.odf i Approved for use outside HVHZ: Yes 1 1`1-15217 R5 11 08-01218B.pdf Impact Resistant: No Verified By: Luis Roberto Lomas 62514 ! Design Pressure: N/A I Created by Independent Third Party: Yes I Other: REFER TO APPROVAL DOCUMENT FOR DESIGN Evaluation Reports PRESSURE RATINGS. I FLIS217 R5 AE 511797C.Ddf Created by Independent Third Party: Yes 115217.8 ! SERIES GA 195 ALUMINUM TRIPLE SERIES GA 295 ALUMINUM TRIPLE SH NI CONTINUOUS SH HEAD AND SILL 108X72 NON IMPACT I Limits of Use Installation Instructions Approved for use In HVHZ: No I FL15217 RS_ 11 08-02247A.odf Approved for use outside HVHZ: Yes i Verified By: LUIS ROBERTO LOMAS 62514 Impact Resistant: No IIi Created by Independent Third Party: YesDesignPressure: N/A Evaluation Reports Other: REFER TO APPROVAL DOCUMENT FOR DESIGN I FL15217 R5 AE 512967A.pdfI PRESSURE RATINGS. ( Created by Independent Third Party: Yes 15217.9 SERIES GA 195 ALUMINUM TWIN ! SERIES GA 195 ALUMINUM TWIN SH NI CONTINUOUS HEAD SH ! AND SILL 88 1/8X72 Limits of Use Installation Instructions Approved for use in HVHZ: No FLI5217 R5 If 08-002 SD.pdf Approved for use outside HVHZ: Yes FL15217 RS II 08-002 6D.pdf Impact Resistant: No Verified By: Luis Roberto Lomas 62514 Design Pressure: N/A Created by Independent Third Party: Yes Other: REFER TO APPROVAL DOCUMENT FOR DESIGN I Evaluation Reports PRESSURE RATINGS. FL15217 RS AE 510335D.pdf Creates Dy 1ncepenoent Two Party: Yes 7 15217.10 SERIES GA 195 ALUMINUM TWIN I SERIES GA 195 ALUMINUM TWIN SH NI CONTINUOUS HEAD 1 SH ! AND SILL 105 3/8X71 ! Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: N/A Other: REFER TO APPROVAL DOCUMENT FOR DESIGN PRESSURE RATINGS. 1S217.11 SERIES GA 275 THERMALLY BROKEN ALUMINUM SH Limits of Use I Installation Instructions Approved for use in HVHZ: No FL15217 R5 11 08-00815D.odf Approved for use outside HVHZ: Yes FLIS217 R5 11 08.0QQ1_6D pdf Impact Resistant- No Verified By: Luis Roberto Lomas 62514 Design Pressure: N/A Created by Independent Third Party: Yes Other: REFER TO APPROVAL DOCUMENT FOR DESIGN Evaluation Reports PRESSURE RATINGS. FL15217 R5 AE 511360C,gdf I Created by Independent Third Party: Yes 15217.12 1 SERIES GA 275 THERMALLY ' SERIES GA 275 THERMALLY BROKEN ALUMINUM SH NI 55 I BROKEN ALUMINUM SH 11/8X90 5/8 r- - --- •------ — Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: N/A Other: REFER TO APPROVAL DOCUMENT FOR DESIGN PRESSURERATINGS.--------- Installation Instructions FLIS217 R5 11 08-00049D.pdf E4153 5 1I -01kq_ - Verified By: Luis Roberto Lomas 62514 Created by Independent Third Party: Yes Evaluation Reports FLIS217 R5 AE 510053D.p Created by Independent Third Party: Yes SERIES GA 275 THERMALLY BROKEN ALUMINUM TILT SH NI 48X72 Installation Instructions t1 FLIS217 R5 Ii 08-02735.Ddf 1VerifiedBy: Luis Roberto Lomas 62514 ! 1 Created by Independent Third Party: Yes Evaluation Reports FL15217 RS AE 511519.ndf i Created by Independent Third Party: Yes 3 of 5 4/17/2018, 8:57 AM Florida Building Code Online http://www.floridabuilding.org/pr/pr app_dti.aspx?param=wGEVXQ... I 15217.13 I SERIES GA 275 THERMALLY f SERIES GA 275 THERMALLY BROKEN ALUMINUM SH NI i BROKEN ALUMINUM SH 1 48X84 J Limits of Use ------------ -' .r. i Installation Instructions I Approved for use in HVHZ: No FL15217 R5 11 08-02715.pdf Approved for use outside HVHZ: Yes I Verified By: Luis Roberto Lomas 62514 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A i Evaluation Reports f Other: REFER TO APPROVAL DOCUMENT FOR DESIGN i FLIS217 R5 AE 513497.pdf i PRESSURE RATINGS. Created by Independent Third Party: Yes 15217.14 I SERIES GA 275 THERMALLY SERIES GA 275 THERMALLY BROKEN ALUMINUM SH NI I BROKEN ALUMINUM SH 36X60 FINLESS — I Limits of Use — - — IIII Installation Instructions Approved for use in HVHZ: No FLIS217 R5 11 08-02720.0f Approved for use outside HVHZ: Yes Verified By: Luis Roberto Lomas 62514 Impact Resistant: No Created by independent Third Party: Yes Design Pressure: N/A i Evaluation Reports Other. REFER TO APPROVAL DOCUMENT FOR DESIGN FLiS217 R5 AE 513504.pdf I PRESSURE RATINGS. Created by Independent Third Party: Yes 15217.15 j SERIES GA 275 THERMALLY i I SERIES GA 275 THERMALLY BROKEN ALUMINUM SH NI BROKEN ALUMINUM SH 48X72 FINLESS Limits of Use — Installation Instructions Approved for use in HVHZ: No FL15217 R5 II 08-02721.2df Approved for use outside HVHZ: Yes i Verified By: Luis Roberto Lomas 62514 Impact Resistant: No Created by Independent Third Party: Yes I Design Pressure: WA I Evaluation Reports Other. REFER TO APPROVAL DOCUMENT FOR DESIGN I FLIS217 R5 AE 513505.odf PRESSURE RATINGS. Created by Independent Third Party: Yes r 15217.16 I SERIES GA 275 THERMALLY SERIES GA 275 THERMALLY BROKEN ALUMINUM SH NI I BROKEN ALUMINUM SH 148X84 FINLESS Limits of Use i Installation Instructions i Approved for use in HVHZ: No FL15217 R5 11 08-02722.p Approved for use outside HVHZ: Yes I Verified By: Luis Roberto Lomas 62514 1 Impact Resistant, No I Created by Independent Third Party: Yes IDesignPressure: N/A Evaluation Reports Other: REFER TO APPROVAL DOCUMENT FOR DESIGN PRESSURE RATINGS. FLIS217 R5 AE 513506.p#f Created by Independent Third Party: Yes 15217.17 SERIES GA 275 THERMALLY i SERIES GA 275 THERMALLY BROKEN ALUMINUM TILT TWIN BROKEN ALUMINUM TWIN SH SH NI 88 1/2X72 1 Limits of Use j Installation Instructions for use in HVHZ: No i FLIS217 R5 11 08-00817D.edfApproved Approved for use outside HVHZ: Yes I FL1S217 R5 11 08-00818D.p4f Impact Resistant- No Verified By: Luis Roberto Lomas 62514 Design Pressure: N/A I Created by Independent Third Party: Yes Other: REFER TO APPROVAL DOCUMENT FOR DESIGN Evaluation Reports PRESSURE RATINGS. FLIS217 R5 AE 511361C.pdf Created by Independent Third Party: Yes 15217.18 ; SERIES GA 505 ALUMINUM SH SERIES GA 505 ALUMINUM SH NI 44X84 FINLESS Limits of Use Installation Instructions Approved for use in HVHZ: No FLIS217 R5 11 08-02723.pdf Approved for use outside HVHZ: Yes Verified By: Luis Roberto Lomas 62514 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: WA Evaluation Reports iOther: REFER TO APPROVAL DOCUMENT FOR DESIGN FL15217 R5 AE 513507.pdf PRESSURE RATINGS. Created by Independent Third Party: Yes ! 115217.19 1 SERIES GA 505 ALUMINUM SH SERIES GA 505 ALUMINUM SH NI 52 1/8X95 1/2 FINLESS Limits of Use Installation Instructions i Approved for use in HVHZ: No FL11217 R5 II 08-02724.p Approved for use outside HVHZ: Yes Verified By: Luis Roberto Lomas 62514IImpactResistant: No Created by Independent Third Party. Yes iDesignPressure: WA I Evaluation ReportsOther: REFER TO APPROVAL DOCUMENT FOR DESIGN FL15217 R5 AE 513508.odf j PRESSURE RATINGS. i Created by Independent Third Party: Yes 15217.20 — — ; SERIES GA 505 ALUMINUM SH j SERIES GA 505 ALUMINUM SH NI 53 1/2X71 1/2 FINLESS 4 of 5 4/17/2018, 8:57 AM Florida Building Code Online http://www.floridabuilding.org/pr/pr app_dti.aspx?param=wGEVXQ... Limits of Use Approved for use in HVHZ: No I Approved for use outside HVHZ: Yes iImpact Resistant: NoDesignPressure: N/A Other: REFER TO APPROVAL DOCUMENT FOR DESIGN PRESSURE RATINGS. Go to Page Installation Instructions FLIS217 RS II 08-02725.12df Verified By: Luis Roberto Lomas 62514 Created by Independent Third Party: Yes Evaluation Reports FL15217 R5 AE 513509.p_df Created by Independent Third Party: Yes Back O 10 O Page l/20 d Contact IJs :: 2601 91tir Stane Road_ Tabhassee Fl, 3j3" FAQ ¢3y-487-1,9 I The State or Florida is an AA/ffD employer. Coovrtoht 2007-2013 State or Florida .:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. U you do rot want your e-mall address released In response to a public -records request, do not send electronic mad to this entity. instead, contact the office by phone or by traditional mat 9 you have arty questions, please contact 850.487.1395. 'Pursuant to Section 455.275(1), Florida Statutes, efrect e October 1, 2012, licensees licensed uider Chapter 455, F.S. must provide the Department with an email address If they have one. The emads provided may be used for official communication with the licensee. However email addresses are public record. 9 you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the pubic. To determine Ir you are a licensee under Chapter 455, F.S., Pleaseclick hp . Product Approval Accepts: r1. ®trKn I Credit Card Safe I 5 of 5 i 4/17/2018, 8:57 AM IXTWMI COIF DISTARcm NOTES. 1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH REOUIREMENTS OF THE FLORIDA BUILDING CODE. 2. WOOD FRAMING AND MASONRY OPENING TO BE DESIGNED AND ANCHORED TO PROPERLY TRANSFER ALL LOADS TO STRUCTURE FRAMING AND MASONRY OPENING IS THE RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. J. IX BUCK OVER MASONRY/CONCRETE IS OPTIONAL WHERE IX SUCH IS NOT USED DISSIMILAR MATERIALS MUST BE SEPARATED WITH APPROVED COATING OR MEMBRANE. SELECTION OF COATING OR MEMBRANE IS THE RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. 4. ALLOWABLE STRESS INCREASE OF 1/3 WAS NOT USED IN THE DESIGN OF THE PRODUCT SHOWN HEREIN. WIND LOAD DURATION FACTOR C6-1,6 WAS USED FOR WOOD ANCHOR CALCULATIONS. 5. FRAME MATERIAL: EXTRUDED RIGID PVC. 6 UNITS MUST BE GLAZED PER ASIM E1300-04. 7. APPROVED IMPACT PROTECTIVE SYSTEM IS REOUIRm FOR THIS PRODUCT IN WIND BORNE DEBRIS REGIONS. B. SHIM AS REOUIRED AT EACH INSTALLATION ANCHOR WITH LOAD BEARING SHIM. SHIM WHERE SPACE OF 1/16- OR GREATER OCCURS MAXIMUM ALLOWABLE SHIM STACK TO BE 1/4', 9. FOR NAIL FIN INSTALLATION INTO WOOD FRAMING OR ZX BUCK USE /10 WOOD SCREWS WITH SUFFICIENT LENGTH TO A04MW A 1 1/4- MINIMUM EMBEDMENT INTO SUBSTRATE LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. 10. FOR FRAME INSTALLATION INTO WOOD FRAMING OR 2X BUCK USE /10 WOOD SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4- MINIMUM EMBEDMENT INTO SUBSTRATE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS 11. FOR FRAME UNSTALLATION INTO MASONRY/CONCRETE USE 3/16- TAPCONS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4- MINIMUM EMBEDMENT INTO SUBSTRATE WITH 2 1/2'' MINIMUM EDGE DISTANCE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. 12. FOR FRAME INSTALLATION INTO METAL STRUCTURE USE 110 SMS OR SELF DRILLING SCREWS YAM SUFFICIENT LENGTH TO ACHIEVE 7 THREADS MINIMUM BEYOND STRUCTURE INTERIOR WALL LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. 13. ALL FASTENERS TO BE CORROSION RESISTANT. DESCRIPTION NOTES 14. INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BF1OW: A WOOD - MINIMUM SPECIFIC GRAVITY OF 6-0.42 B. CONCRETE - MINIMUM COMPRESSIVE STRENGTH OF 3,192 PSI. C. MASONRY - STRENGTH CONFORMANCE TO ASTM C-90, GRADE N. TYPE I (OR GREATER). D. METAL STRUCTURE: STEEL ISGA, JJKSI OR ALUMINUM 6063-TS 1/8- THICK MINIMUM MI WINDOWS AND DOORS 1001 W. CROSBY RD. CARROLLTON, TX 75006 SERIES 5500 CHS SINGLE HUNG TWIN WINDOW NON -IMPACTNOTES J.L- 1 08-01928 SIGNED: O&IM015 Be' MAX FRAME WIDTH 9' MAX RY CNN rN2 /Iei1m J_ MAX rT OC. --1 J' NAx • ADOW EDGE DISTANCES 05/-e/I5 RL ANCHORS TO BE EOVALLY SPACED SEE CHART BELOW FOR NUMBER OF ANCHORS REOUIRED Bow a4' MAX FRAMEHEIGHT /( ,/ fir Mun0 YrntAY /rYOYrnOrbY RY 7AOIN MI NON NO AO AO 120 1 N tl0 tl0 720 r/0 SERIES 5500 CHSSINGLE HUNG TWIN WINDOW Naa . Nu wr Na2 are NNS ar. EXTERIOR VIEW MO FIN VWAUATION I00 7 7 r r 7 tl DESIONPRESSURE7N70ND I IMPAOTRATYVO rio r 7 r r r a + r ro a ro 15OPSF NONE ro + r r w r w ladmum g!gg;FnsyWNINM) mova NO a" AO 1 .20 MI me N00 72o rto ee Mq /Y N Ier NCO IY Mp o wo 7r w0 r 7a w no tl0 w0 7a0 w0 I 7a0 WO 7a0 tl0 7a0 tlo720 wo 7so w0 o w0 n+ w0 NA 0 7s 70 0 + MO w o nr 000 a17 w0 wA SIGNED: O&IS2015 MI WINDOWSwWcaosBOT DOORS `\`\S CARROLLTON. TX 75006 .J••GEN,pF'+p SERIES 5500 CHS SINGLE HUNG TWIN WINDOW S*• O •= NON —IMPACT NAIL FIN ELEVATION p • TATE NTS OI22I0TrcN2o oe-0 2e A iiis GNAl32OF6l\ \ tt 1 E.- MAY FRAME WIDTH 6' MAX 6• A Amm EORS OtSTANCCS 05/1E/15 ILL 6-MAX 11 ANCHORS TO BE EQUALLY SPACED SEE MB BELOW NUFORNUMBER OF ANCHORS REQUIRED MAX a.- FRAMEHEIGHT SERIES SSW CHS SINGLE HUNG TWIN WINDOW EXTERIOR VIEW FRAME 06TAL A71W OESIGNPRESSUREMTWG WPACTMTING t50PSF Np4E Ydmu dad n •.T w.••Wrm M MAP. 3.0 1 300 1 no I •10 Itil At0 tl0 Ro MO IAV P•• .tt0 ti Mq IMF oW D 7 500 1" 309SD mo no I tl0 tlo 0 tl0 500 tl0wOisSOND300Im720 tlt tl 700 tl0 0 D tl0 01 L f6 up wo I ram I WO o SIGNED.ON7&WI5 rAeo. r:.rr /wow ru• MI WINDOWS AND DOORS 5 O1 111111II1 a.•• wtm lM 1001 W. CROSBY RD. nw. S. tlo >tro N.oCARROLLTOH. TX 75006 •'GENy:y ro> . ao tlo no o F • I wY A•r wu Ar wu IA-1wAa A SERIES 5500 CHS SINGLE HUNG TWIN WINDOW _*• 0 /5 -11. r 7t w NON -IMPACT p • TATOF tl0 7tFRAMEELEVATION7so0 o u t u s Wuw. o.c •a icv %'FB:;OR10T: ? oa to t u tY to t to owc 03-0192E A ONA 11E HIS022220133OF6itu I WOOD FRAMING OR 2X BUCK BY OTHERS EXTERIOR I WOOD FRAMING OR 2X BUCK BY OTHERS 1/2 . EDCE DISTAMINNCE METAL STRUCTURE 1 1/A' MIN. BY OTHERS EYBE Eril 1/A' MAX. SMM SPACE 110 WOOD SCREW INTERIOR EXTERIOR TO BE SILL TO BE IN A BED OF SET IN A ROVED SEALANT BEO OF APPROVED u' MAX. SEALANT u SPACE METAL STRUCTURE BY oTHLRS VERTICAL CROSSSECTION WOOD FRAMING OR 20 SUCK INSTALLATION NOTES. I. INTERIOR AND EXTERIOR FwSIIEA BY017011 NOTSHOWNFOR CLARNY 2 PERIMETER AND JOINT SEALANT BYO"WRS TO BE DESNGAZO OJACCORDANCE WITNASTMEV 12 IXVDPIS 3/4' MIN. EDGE DISTANCE A ADDED FSCf LX51ARtY5 as I/A- MAX. SHIM SPACE 1/4- MAX. FSHIM SPACE Ylof INTERIOR 3/A' MIN. EDGE DISTANCE SMS OR SELF DRILLING 110 SMS OR SCREW SELF DRILLINGSCREWS METAL EXTERIOR STRUCTURE By OTHERS JAMBINSTALLATIONDETAIL INTERIOR METAL STRUCTURE INSTATIATON 1 1/4' MIN. 1/4' MAX. EMBEDMENTEMBEDrSHIM SPACE I INTERIOR 1/ 2' MIN. EDGE DISTANCE 110 WOOD SCREW WOOD FRAMING OR 2X BUCK EXTERIOR BYOTHERS1/ 4' MAX. JAMB INSTALLATION DETAIL i--ISHIM SPACE WOOD FRAMING OR 2A SUCKWSTALlATON VERTICAL CROSS SECTIONMETAL STRUCTIM 4AISTALLATION SIGNED. O&M2015 1 2 1 /2" YIN. EDGE DISTANCE CONCRETE/MASONRY BY OTHERS 1 1/1- YIN OPTIONALIX BUCK EMBEDMENT TO BE PROPERLY SECURED1 1/4" MIN, SEE NOTE 3 SHEET I 1 EMBEDMENT CONCRETE/ MASONRY 1/ a- MA74 BY OTHERS SHIP SPACE OPTIONAL Ix BUCK TO BE PROPERLY 3/ 16" TAPCON SECURED SEE NOTE 3 SHEET I 3/ 16" TAPCON EXTERIOR6INFERIORNIN, SILL TO BE SET IN A BED OF APPROVED SEALANT U 1/4- MAX. OPTIONAL BUCK SHIM SPACE TOBE TO BEPROPERLYSECURED SEENOTE } SHEET I CONCRETE/MASONRY '\ BY OTHERS \ • , VERTICAL CROSS SECTION CTNCRETEYASONIWINSTAWTTA N OW"ANOSu SHOWTVJMMSBaAR 1/4" 40, SHIM SPACE INFERIOR EXTERIOR JAMB INSTALLATION DETAIL ODNCREIDMASO/RYMbTALAW NOTES I. !/ TERIORAND EXTERIOR FINISHES, BYOTNM NOTSNOWNFORCARRY, L PERIYETERAND JOINT S& BY DRIERS TO BE OESICNEO IN ACCORDANCE YAMASTM EV It SIGNED: O/TS? OI7 1 BEHIND FIN 1 1/4' MIN. EMBEDMENT i10 WOOD W000 SCREW t-1NG BY OTHERS 1/4- MAX. SHIM SPACE 1/2- MIN EDGE DISTANCE EXTERIOR 11 16 INTERIOR 1/4- MAX HIM SPACE 1/2- MIN 1 EDGE DISTANCE 010 WOOD WOOD SCREW 1 1/4- NIN, BY OTHERS APPROVED SEALANT I EMBEDMENT BEHIND FIN VERTICAL CROSS SECTION WOOD FRAMING OR 2X BUCK Al4TAILA TTON MW AND SBL S"OWNJA IMSSUAR ADOM EDGE OISTANOM WOOD FRAMING 1/4- MAX SHIM SPACEByoTHERS 10 wo00 INTERIORSCREW 1 1/4' MW. EMBEDMENT APPROVED SEALANTBEHINDiW 1/2' NIN EXTERIOREDGEDISTANCE JAMB INSTALLATION DETAIL WOOD FRAMING OR VBUGTNLSTAILATION MOTES. 1, WTERIORAND EXTERIOR FW SNES BYOTHERS, hWSMOWNRORCLAAW. P PERYNEMPANO JOI TSEALANT BYORIERS TOSE oESIGNED INAOOOWGANGEWTMASTIM EI1Ta MI WINDOWS AND DOORS BOOB W. CROSBY RD. CARROLLTON, TIT 75006 SERIES 5500 CHS SINGLE HUNG TWIN WINDOW NON -IMPACT FIN INSTALLATION DETAILS A UC wp J.L 06-01926 SIGNS& W182015 s REQUIRED INSPECTION SEQUENCE lmmqi. 14 ftl wmc; P ERfir T I[nn Max' Inspection Description Footer / Setback Stemwall Foundation / Form Board. Survey Slab / Mono Slab Pre our Lintel / Tie Beam / Fill / Down Cell Sheathing — Walls- Sheathing— Roof Roof Dry In Frame Insulation Rough In Firewall Screw Pattern Drywall / Sheetrock Lath Inspection Final Solar Final Roof Final Stucco / Siding Insulation Final Final Utility Building Final Door. Final Window ' Final Screen.Room Final. Pool Screen Enclosure. Mobile Home Building Final Pre -Demo Final. Demo FinalSingle Famil' - Residence Final. Building Other Address: Nfln max IIns ecti®n.IIDescnitionn Electric Underground Footer / Slab Steel Bond Electric Rough T.U. G. Pre -Power Final Electric Final irJLIMpf _.. 7 1.: .p.,f .R. L.y ' •.:•. ..-':.o~• a t i! > T•i f-r :. .., _ . L ITV::!!JL•r7C ICill_GQC"4 `- X . 4•~K; .`p -C`-; r:' min Max. Inspection Description Mechanical Rough Mechanical Final. Maw rnsi2ection, IIDescsn Lion Gas Underground Gas Rough Gas Final REVISED: June 2014