417 12 St - BR18-003007 (a) Interior AlterationA SCITY OF JUL 0 9 201buildin & Fire Prevention Division ANFORD g PERMIT APPLICATION FIRE DEPARTMENT Application No: ' :i57;_810a# a CD / Documented Construction Value: S .. 417 12th ST., SANFORD FL 32771JobAddress: Historic District: Yes No Parcel ID: 25-19-30-5AG-1 407-0060 Residential Commercial[] Type of Work: New[] Addition Alteration Repair Demo[] Change of Use[] Move El Description of Work: INTERIOR ALTERATION: Electrical and Mechanical work. Replace drywall, baseboard, floor laminate, interior door, kitchen cabinets, interior & exterior painting. Plan Review Contact Person: Juan Vasquez Title:CGC Phone: 407-219-8252 Fax: Email: JUAN@3VDCONSTRUCTIONS.COM Property Own r I formation Name JESSICA CARRION (5q&5t_%56(*qg r i Phone: 407-301-7891/452-9356 Street: 2874 BERKSHIRE CIR. Resident of property? : NO City, State Zip: KISSIMMEE, FL 34743 tractor In or do Name JUAN A VASQUEZ MATA °'^I'YL' ne: 407-219-8252 Street: P.O. BOX 560172 Fax• N/A City, State Zip: ORLANDO, FL 32856-0172 State License No.: CGC1520470 Architect/Engineer Information Name: OSCIEL PLAZA Phone: 407-217-4464 Street: 2552 GREENWILLOW DR Fax: City, St, Zip: ORLANDO, FL Bonding Company: Address: N/A E-mail: Mortgage Lender: Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Application is hereby made to obtain a permit to do the work and installations as indicated. 1 certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. 1 understand that a separate permit must be secured for electrical work, plumbing, signs; wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: 611 Edition (2017) Florida Building Code Revised: January 1, 2018 h Permit Application NOTICE: In addition to the requirements of this pen -nit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance ofpermit is verification that I will notify the owner of the property of the requirements ofFlorida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal. The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value, credit will be applied to your permit fees when the permit is issued. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. 71 6-Alwv, Xi Owner/Agent Date Signature of ctor/Agent ate e , Name Signature o *flotary-State of Florida Owner/Agent is Personally Produced ID )C Type of ID C Date SANTOS ECHEVARRIA NOTARY PUBLIC STATE OF FLORIDA Comnsd OG 111802 NhMWnoz11 44Zd--X--hD -0 q of Notary -State of Florida Date ANNETTE BLAND Notary Publlt: State of Florida Commission # GG 060623 or F. My Comm. Expires Jan 16, 2018 tt>77 wn to Me or Type of ID BELOW IS FOR OFFICE USE ONLY Permits Required: Building ElectricalJ2(Mechanical Plumbing Gas Roof Construction Type: Occupancy Use: Total Sq Ft of Bldg: Min. Occupancy Load: New Construction: Electric - # of Amps, Fire Sprinkler Permit: Yes No # of Heads sdr r_ t'A'%04 APPROVALS: ZONING: ' I - UTILITIES: ENGINEERING: COMMENTS: F FIRE: Flood Zone: of Stories: Plumbing - # of Fixtures, Fire Alarm Permit: Yes No WASTE WATER: BUILDING: SC S-/6 - t t Revised: January 1, 2018 Permit Application SCPA Parcel View: 25-19-30-5AG-1407-0060 Page 1 of 2 CIA Parcel Information Property Record Card Parcel: 25-19.30-SAG-1407-0060 Property Address: 417 W 12TH ST SANFORD, FL 32771-2859 Parcel 25.19-30-SAG-1407-0060 Owner(s) SUZUKISERG98INC Property Address 417 W 12TH ST SANFORD, FL 32771-2859 Mailing 2874 BERKSHIRE CIR KISSIMMEE, FL 34743-5656 Subdivision Name SANFORD TOWN OF Tax District S4-SANFOR0. 17-92 REDVDST DOR Use Code 0112-RESD STRUCTURE W/COMM LAND Exemptions 117 6 a 5 r O U')_ r Value Summary 2018 Working 2017 Certified Values Valuation Method Cost/Market Cosl/Market Number of Buildings 3 3 Depreciated Bldg Value 161.864 148,904 Depreciated EXFT Value 600 600 Land Value (Market) 35,100 35.100 Land Value Ag Just/Market Value " 197,564 184,604 Portability Adj Save Our Homes Adj SO SO Amendment 1 Adj SO SO P&G Adj O SO Assessed Value 197,564 S184,604 Tax Amount without SOH: $3,515.13 2017 Tax Bill Amount $3,515.13 Tax Estimator Save Our Homes Savings: $0.00 Does NOT INCLUDE Non Ad Valorem Assessments Legal Description LOTS 6 + 7 BLK 14 TR 7 TOWN OF SANFORD PS 1 PG 57 Taxes Sales Find Comparable Sales Land Taxing Authority Assessment Value Exempt Values Taxable Value County General Fund 197,564 O 197,564 Schools 197,564 O 197,564 City Sanford 197,564 SO 197,564 SJWM(Saint Johns Water Management) 797,564 O 197,564 County Bonds 197,564 SO 197,564 Description Date Book Page Amount Qualified Vac/Imp WARRANTY GEED 12J1/2017 09039 1105 253,000 Yes Improved WARRANTY DEED 6/1/2017 08938 0708 227,000 Yes Improved QUIT CLAIM DEED 6/1/2014 08278 1461 100 No Improved QUIT CLAIM DEED 1l112014 08204 1294 5700 No Improved QUIT CLAIM DEED 9/1/1998 03863 0773 E75,000 No Improved WARRANTY DEED 6/1/1992 02445 0700 530,000 No Improved CERTIFICATE OF TITLE 9/1/1991 02333 0220 28,300 No Improved WARRANTY GEED 7/1/1987 01866 1886 543,000 Yes Improved WARRANTY DEED 5l1/1986 01733 0777 538,000 Yes Improved Method Frontage Depth Units Units Price Land Value SQUARE FEET 0001 0.00 11700 3.00 35,100 http://parceldetail.scpafl.org/PazcelDetailInfo.aspx?PID=2519305AG 14070060 7/9/2018 n DESIGN & CONSTRUCTION 3vn Co,YS'rRUCTIO:NS LAC CCRI'ITII:D GFURRAI. CON'rRACIOR I:GC1320470 1 CERTIFIED ROOFING CONTRACTOR CI;C1130851 OWNER & CONTRACTOR AGREEMENT Owner and Contractor enter into this agreement ("Agreement") on July 08, 2018. OWNER CONTRACTOR JESSICA CARRION JUAN A VASQUEZ MATA Name Full Company Name SUZUKISERG98 INC 3VD CONSTRUCTIONS LLC Address Address 2874 BERKSHIRE CIR. P.O. BOX 560172 City, State, Zip City, State, Zip KISSIMMEE, FL 32743 ORLANDO, FL 32856-0172 Phone Phone 407-301-7891 407-219-8252 For good and valuable consideration, the Parties agree as follows: 1. PROPERTY ADDRESS. The address on which the Project, as defined below, is to be performed is: 417 121h ST., SANFORD, FL 32771. 2. SCOPE OF WORK. Contractor will provide labor, materials, and equipment to perform the work on the Exhibit "A" Construction Specifications and Allowances and the following described architectural plans, if any: SEE ATTACH ENGINEERING PLANS. 3. PRICE OF WORK. Owner will pay Contractor $ 62,802.87("Price") per the payment schedule in' paragraph 5. The Price includes the costs of labor and materials to complete the Project and Contractor's compensation. 4. ALLOWANCES. An "allowance" is not a fixed amount, but rather Contractor's estimate of the cost of an item (e.g., paint, fixtures, and appliances) for standard grade materials. As Owner makes a selection having an allowance, the actual cost will be included in the Price without a Change Order. At any time, Owner may request Contractor to prepare an updated allowance statement showing variances between allowance estimates and actual allowance costs. 5. PAYMENTS TO CONTRACTOR. A) Deposit. Owner will deposit $1,000.00 with Contractor when this Agreement is signed and submit the Building Permit. B) 2nd Paymentt. Owner will deposit $20,498.00 when the Building Permit is issued C) Progress Payments. Owner will pay Contractor per the Exhibit "B" Payment Schedule. Failure to make progress payments in full when due will immediately excuse Contractor from continued work. Any delay in making a progress payment in full will extend Contractor's date for achieving Substantial Completion (defined below) " length of the delay. W 407.219.8252 0 4601 \cptunc Road. St. Cloud 11rida 34769 W luan 1, 3vdconstructiuns.com I w w%v.3vdcunstructioIn.coin Rn- DESIGN & consTRuc•rlon 3vu coms•rRUCTIOVs LLC CCRrIF11:D CF.NCRAI. CONTRMTOR CGCI320470 I CGR71FIF.D ROOFING CONTRACTOR Mr1.130553 Change Order Agreement Change Order # Exhibit "C" This Change Order, made , 20 , modifies the Construction Agreement Agreement") between the Parties. For the consideration below, Contractor will furnish all labor and materials necessary to complete the following: The total price of this work is $ the Price in the Agreement. Change Order Price"), which is in addition to Owner will pay the Change Order Price as follows: As a result of this Change Order, the estimated date for Substantial Completion is extended by days. All other terms of the Agreement apply to this Change Order. L/ 4/ice Owner's Signature Date Ownerr's Signature Contractor's Date Date 6 407.219.8252 0/601 Nleptune (toad. St. Cloud Florida 34769 W juan@3vdconstrtictions.cnn7 1 %v%v%v.3vdconstructions.cnln THIS Name:JINSTRUMENT ABQUEZ MAT ' GRANT MALOY r SEMINOLE COUNTY Address: CLERK OF CIRCUIT COURT & COMPTROLLER BK 9169•P9 353 (1P9s) CLERK' S T 2018078683 RECORDED NOTICEOFCOMMENCEMENTRECORDINGOFEES /$10.010I3:sv:oi PM State of Florida RECORDED BY tsm i th County of Seminole Permit Number: Parcel ID Number. 25-19-30-5AG-1407-0060 The undersigned hereby gives notice that Improvement will be made to certain real property, and In accordance with Chapter 713, Florida Statutes, the following information Is provided in this Notice of Commencement QE CRlPL0 1 DF LROP R L• (al description of the property and street address If avallable) L . ViENERAL JDE$ TYICIbI pHmP,,i4OVEMENT: IOWNER INFORMATION: Name:_SUZUKISERG98 INC (JESSICA CARRION) Address: 2874 BERKSHIRE CIRKISSIMMEE, FL 34743 Fee Simple Title Holder pf other then owner) Name: Address: CONTRACTOR: Name: JUAN A VASQUEZ MATA Address: P. O. BOX 560172, ORLANDO FL 32856-0172 Persons within the State of Florida Designated by -Owner upon whom notice or other documents may be served as providedbySection713.13(1)(b), Florida Statutes. Name: Address: In addition to himself, Owner Designates of To receive 9 copy of the Uenoes Notice as Provided in Section 713. 13(1)(b), Florida Statutes. Expiration Date of Notice of Commencement (The expiration date Is 1 year from date of recording unless a different dateIsspecified) WARNING TO OWNER: ANY -PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OFCOMMENCEMENTMUSTBERECORDEDANDPOSTEDONTHEJOBSITEBEFORETHEFIRSTINSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. Under penalties of perjury, 1 declare that I have read the foregoing and that the facts stated In it are true to thestofmyknowledgeandbelief. SS t Cet C","•r• Signature Owners Minted Name Flrnlda Statute 71313(1HOk -The owner must slpn the notice of oommmmoertmenl and no one else may be permitted to sign In his or her stead.' Stateof vF., County of (/JCm: c'o- The foregoing Instrument was acknowledged before me this G day of -,,J4( 2p / r- by \ ffrlc G i p17 •- ------- Name of person making statement OR who has produced Identification ® type of Identif SANTOS ECHEVARRIA NOTARY PUBLIC c STATE OF FLORIDA Cann# G1G111602 Expires 6WO21 REQUIRED INSpECTI[Olq- S]EQU]ElqCE. lmwh" AL Tr- 12a m Iza fB*k-99mG rkpt W'.. mar Footer Setback SternwaU Foundation• / Form Board. Survey Slab- IMono Sri& Pre our Lintel / Tie- Beam / Fill Down Cell Sheathing— Walls Sheathing— Roof Roof Dry In P Frame Z11> Insulation. Rough- In- FirewaU Screw Pattern Drywall / Sheetrock Lath Inspection Add min max D escn* 2don Electric. Underground Footer I Slab Steel Bond Electric Rough T.U.G. Pre -Power Final Electric Final a, .Um Mechanical Gas Unde Gas Ro Gas Final Final REVYSED: June 2014 RECORD COPY SUZUKISERG98 Inc 417 W 12th ST. SANFORD FL 32771 PARCEL ID #25-19-30-5AG-1407-0060 INTERIOR ALTERATION REVIEWED FOR CODE COMPLIANCE (Single Family Residence) S — PLANS EXAMINER ir- Icv- IS DATE ASPHALT 4-ADWAY Y CVx ec LD:X OF PAVEVEAT SL1 1p2' do CA L rouNo ho Irrn S2D7X o X PLA- N 89'25'44" E I17't:) 1r N NN I 1 0T 6n 4 TER ! irw Im METAL e FL iLDING I" N LI127-2 LOT 7 OCK 14 a• TIE` 7 1 N 85'25'44" E 117'lPi FOUND 1/2- IRON CAP, NO: LECII PROJECT INTERIOR ALTERATION SETBACKS — SITE PLAN SCALE 1/64- = V DO - I I SCOPE OF WORK INTERIOR ALTERATION. ELECTRICAL AND MECHANICAL WORK. DRYWALL, BASEBOARD, FLOOR LAMINATE, INTERIOR DOOR, KITCHEN CABINETS, INTERIOR AND EXTERIOR PAINT. INDEX SHEET DESCRIPTION G1 SITE PLAN. SETBACKS. NOTES. Al EXISTING FLOOR PLAN/DEMO. A2 PROPOSAL FLOOR PLAN. E1 ELECTRICAL PLAN. M1 MECHANICAL PLAN. D1 DETAILS. D2 DETAILS. SCHEDULE AREAtso SPACES LV I N V IGRM SINGLE FAMILY 1 1144 214 SINGLE FAMILY 2 486 P3! 8 STEEL/PRE ENG. 300000 TOTAL LIVING AREA 1630 TOTAL GROSS AREA 14844 i SETBACKS BUILDING LF FRONT 11.5 REAR 40.5' RIGHT SIDE 5.4' LEFT SIDE 74.3' row%o a NC fl tN, SANFORD BUILDING DIVISION A PERMIT ISSUED SHALL BE CONSTRUED TO BE A LICENSE TO PROCEED WITH THE WORK AND NOT AS - AUTHORITY TO VIOLATE, CANCEL, ALTER OR SETASIDEANYOFTHEPROVISIONSOFTHETECHNICALCODES, NOR SHALL ISSUANCE OF A PERMIT PREVENTTHEBUILDINGOFFICIALFROMTHEREAFTERREQUIRINGACORRECTIONOFERRORSINPLANS, CONSTRUCTION OR VIOLATIONS OF THIS CODE SUILD/4 SANFpRO 1 g- 3 0 0 7 o AAR' See survey attached 13><.7IMMMI SINGLE FAMILY 1 13M SF SINGLE FAMILY 2 486 SF STEEL/PRE ENG. INSULATED 3000 SF DRIVEWAY —SIDEWALK —ACCESS 400 SF LOT AREA 11700 SF IMPERVIOUS AREA 44 JUL 0 9 2018 Cv co N O ci z=_ w P j :V z EXPOSURE CATEGORY : B BASIC NAND SPEED 140 INTERNAL PRESSURE COEFFICIENTS BUILDING, ENCLOLSED +/— 0.18 NAND IMPORTANCE FACTOR 1 ROOF DESIGN NAND PRESSURE 30 PSF FBC, SECTION 1604.6 WINDOW DESIGN NAND PRESSURE: A. POSITIVE PRESSURE OF 22 P.S.F. B. NEGATIVE PRESSURE OF 30 P.S.F. DOOR DESIGN NAND PRESSURE: SLIDING GLASS DOORS : ALL SIZES A. POSITIVE PRESSURE OF 21 P.S F. B. NEGATIVE PRESSURE OF 28 P.S.F. ENTRY DOOR: ALL CONFIGURATIONS A. POSITIVE PRESSURE OF 20 P.S.F. B. NEGATIVE PRESSURE OF 25 P.S.F. MINIMUM DISTRIBUTED LIVE LOADS BALCONIES AND DECKS (EXTERIOR) 40 Psf GUARDRAILS AND HANDRAILS 200 Pef GUADRAILS IN —FILL COMPONENTS 50 Psf PASSENGER VEHICLE GARAGES 50 Psf ROOMS OTHER THAN SLEEPING ROOMM : 40 Psf SLEEPING ROOMS 30 Psf STAIRS 40 Pef NOTES THIS STRUCTURE HAS BEEN DESIGNED TO MEET OR EXCEED THE 140 MPH WAND LOAD REQUIREMENTS OF SECTION III OF THE FLORIDA BUILDING CODE 2017 EDITION RESIDENTIAL. THIS STRUCTURE HAS BEEN DESIGNED TO MEET OR EXCEED THE MECHANICAL, ELECTRICAL & PLUMBING REQUIREMENTS OF ALL APPLICABLE STATE AND LOCAL CODES AND ORDINANCE. ELECTRICAL PLAN : BASED IN NEC 2014 MOBILE/MANUFACTURED HOME SET—UP, REPAIR AND REMODELING SHALL COMPLY WITH THE MOBILE MANUFACTURED HOME INSTALLATION STANDARD DISCREPANCIES IN DRAWINGS 1— THE BUILDING CONTRACTOR/OWNER SHALL CHECK ARCHITECTURAL, PLUMBING MECHANICAL, ELECTRICAL. STRUCTURAL DRAWINGS FOR OPENINGS, WINDOWS, SLEEVES, ANCHORS, HANGERS, SLAB DEPRESSIDNS. DIMENSIONS, PITCH AND EITHER RELATED ITEMS AND SHALL ASSUME RESPONSBIUTY FOR THEIR PROPER LOCATION, PLACEMENT AND CONTINUITY AND BEARING POINTS ON ROOF AND FLOOR TRUSS/RAFTER PLANS TO BE REFLECTED ON FOUNDATION PLANS THE PROFESSIONAL OF RECORD SHALL BE NOTIFIED IN WRITING OF ANY VARIATION OR DEVIATION IN THE DIIESONS, CONDITIONS. AND SPECIFICATIONS ON THESE PLANS. 2— GENERAL CONTRACTOR. SUBCONTRACTOR, MECHANICAL. ELECTRICAL AND PLUMBING CONTRACTOR TO INSPECT THE EXISTING CONDITION PRIOR TO COMMENCING THE PROPOSED CONSTRUCTION. 3— ALL MATERIALS AND FINISHES TO MATCH EXISTING BUILDING. 4— ADHERE TO ALL STATE. COUNTY AND LOCAL CODES. 0 n 06 N 9 OZ o N O Qdy o erg C o C.D ' ZO14D z QN FUog n UZU a J a is a FS U Z f W le EVISIONS 00 M z 0-) Fa 0o i LLz Ld "d a Cn 0 ns z N:; L/') DATE O6/18/2018 NUMBER 2018-0033 SHEET G1 EXISTING CONCRETE STAIRS TO REMAIN F EXTERIOR WOOD FR i F PORCH n a EXISTING FLOOR N aG JOIST TO REMAIN BRICK COLUMN TO REMAIN EXISTING FLOOR PLAN SCALE 3/16': 1'-00' 8' 3'-4' 2'-2' EGRESS 2 SH 25 EGRESS SH.25 EXTERIOR 18.5 -31I.A IWOOD FRAME W La 0 BEDROOM 1 " BEDROOM 2 c I ; CLOSET FFF01 m ATTIC ACCESSATH OSET AHUU il----' LIVING DINING EXISTING FIREPLACE TO REMAIN EXISTING FLOOR JOIST TO REMAIN a 0 EXTERIOR WOOD FRAME 1 11F KITCHEN JI'-44 B'-8' I1'-11' —4'-1' I 6. 1 6'-10' 1 i0'-2- Ig-6' I 1 10' 1 38, 18. 5 -31. 0' ou 001111S m z n 11111I lip b IZZ a33 DEMOLITION/ ALTERATION Sk 6 TAG DESCRIPTION OF ALTERATION i- A REMOVE INTERIOR WOOD FRAMING ( NON BEARING' B REMOVE BIFOLD CLOSET DOOR id"// C NEW INTERIOR WOOD FRAME WALL (NON BEARING) EXISTING WOOD STAIRS TO REMAIN EXISTING WOOD RAMP TO REMAIN DEMOLITION NOTE 1- WEAR PROTECTIVE GEAR WHEN DEMOLISHING AREAS PRONE TO DUST AND/OR OTHER AIRBORNE PARTICLES. 2- LEAVE ALL PLUMBING STUBS WHERE NOTED, OTHERS NOT NOTED TO BE CAPPED/MOVED. 3- EXTENT OF DEMOLITION SHOWN ON THIS PLAN IS INTENDED TO SHOW WALLS AND WINDOWS AND EXTERIOR FINISHES/COMPONENTS. PLAN DOES NOT SHOW INTERIOR FINISHES, FIXTURES OR CEILING REMOVAL WHICH WILL BE REQUIRED AND WALL BE COORDINATED IN THE FIELD. 4- OWNER/DESIGNER ASSUMES NO RESPONSIBILITY FOR ACTUAL CONDITION OF STRUCTURE TO BE DEMOLISHED. 5- DISCONNECT UTILITY SERVICES PRIOR TO DEMOLITION. 6- FILL IN ALL CAVITIES AND ADJUST SOIL ACCORDINGLY BASED ON SITE ANALYSIS. 7- ALL DEMOLISHED MATERIALS TO BE REMOVED AFTER COMPLETION OF JOB, NO MATERIAL LEFT ON SITE OR IN SOIL. 8- EXISTING WALLS DEPICTED ARE CLOSE APPROXIMATIONS BASED ON MEASURED FIELD DATA. WHILE THE ACCURACY OF THE DEPICTED INFORMATION IS GOOD, FIELD SHOULD VERIFY ANY DIMENSIONS WITH A VISUAL IF SOMETHING IS IN QUESTION. ABREVIATION LIST 0. x$. o c , 461) O5 0 l111 A/ C AIR -CONDITIONER AHU AIR HANDLER UNIT BF BIFOLD DOOR D DRYER DISP DISPOSAL DW DISH WASHER ELEV ELEVATION GC GENERAL CONTRACTOR HB HOSE BIBS LAV LAVATORY MW MICROWARE N. T.S NOT TO SCALE SO SMOKE DETECTOR SF SQUARE FT S. Y.P SOUTHERN YELLOW PINE TEMP TEMPERED TYP TYPICAL U. N.O UNLESS NOTED OTHERWISE W WASHER W/ WITH W/ C WATER CLOSET WP WATER PROOF LV LIVING AREA - HEATER NLV NON LIVING AREA GR TOTAL GROSS AREA T) SAFETY -GLASSING WINDOW/ TEMPERED 09§ 5 E N pp U Q NNp p C La i3 QW1 r o a c REVISIONSI U Cr n 00 Z 0 Q b o i L L. I . z LLJ 44 b Q vt 0 O_ Y^ g ck: Dn_ Z Na D V ) IDATE I 06/18/2018 NUMBER 2018- 0033 SHEET Al 28' r-2'-6• 6'-5• -1 2'-s• -2'— 2'-2• EXISTI CONCR STAIRS REMAIN WINDOW & DOOR SCHEDULE ITEMS SIZE ROUGH OPENING MATERIALS Ai WINDOWS SH.34 53-1/8"x50-5/8" 53-5/8"x50-7/8" GLASS VYprL SH.25 37"x63" 37-1/2"x63-1/2" GLASS jf'Nt4 SH.1/2 33 26-1/2"x38-3/8" 27"08-5/8" GLASS Y T) = SAFETY- GLASSING WIND W / TEMPERED 1i DOORS 3068 SC 36'x8O" 38"x82"-EXT. SOLID CORE WOOD WOOD 1> 2668 SC 30'x8O" 32"x82"-EXT. SOLID CORE WOOD WOOD 2668 OR 30" x 80" 32"x82"-INTERIOR HOLLOW CORE WOOD 2068 DR 24" x 80" 26"x82"-INTERIOR HOLLOW CORE WOOD W00 POCKET DOOR PD-2080 24"x80" IN THE WALL HOLLOW CORE WOOD WOOD BIFOLD DOOR BF-4068 48'x8O' 48"x81" INTERIOR HOLLOW CORE WOOD WOOD SF-2868 32'x80" 32•x81" INTERIOR HOLLOW CORE WOOD WOOD o r00n a33 o o at b u YFoSoc 110 11O11 DEMOLITION/ALTERATION SCHEDULE TAG DESCRIPTION OF ALTERATION A REMOVE INTERIOR WOOD FRAMING ( NON BEARING) B REMOVE BIFOLD CLOSET DOOR k NEW INTERIOR WOOD FRAME WALL (NON BEARING) LUMBER NOTE ALL WOOD FRAMING MEMBERS THAT REST ON CONCRETE OR MASONRY EXTERIOR FOUNDATION WALLS AND ARE LESS THAN 8 INCHES FROM THE EXPOSED GROUND TO BE SOUTHERN YELLOW PINE No. 2 WITH MAX. CONTENT OF MOISTURE 19 PRESSUE TREATED. IN ACCORDANCE WITH AWPA U1. ALL LUMBERS TO BE SOUTEHRN YELLOW PINE No. 2 WITH MAX. CONTENT OF MOISTURE 19 PRESSURE TREATED. 6 Fa_ 0 101REVISIONS1 U C M n W Z C-) Q b of ww J Lu "' 1 a 7) i 0_ O Ne nd z N' D DATE 06/18/2018 NUMBER 2018-0033 SHEET A2 1. ELECTRICAL OUTLETS (RECEPTACLES AND LIGHTING) BELOW BASE FLOOD ELEVATION SHALL BE INSTALL -LED AT THE HIGHEST PERMITTED ELEVATION AND SHALL BE INSTALLED ON (SEPARATE) INDEPENDENT CIRCUITS FROM THOSE IN THE HABITAL AREAS. 2. NO APPLIANCES OR APPLIANCE OUTLETS SHALL BE INSTALLED BELOW BASE FLOOD ELEVATION. 3. A/C COMPRESSORS SHALL BE INSTALLED ABOVE BASE FLOOD ELEVATION. 4. MAIN CIRCUIT BREAKER PANEL SHALL BE LOCATED ABOVE BASE FLOOD ELEVATION. 5. PRIOR TO INSTALLATION OF ROUGH ELECTRICAL WRING, CHECK NAMEPLATE DATA OF A/C EQUIPMENT, HOT WATER HEATERS, AND OTHER EQUIPMENT TO OBTAIN CORRECT WARE SIZES AND OVERCURRENT PROTECTION. 5. ARC FAULT OUTLETS AT ALL BEDROOMS TYPICAL. 6. SMOKE / CARBON MONOXIDE (COMBO) DETECTORS SHALL BE IN ALL SLEEPING AREAS; SHALL BE INTERCONECTED; SHALL BE 3' FROM WITHIN 1' TO 3' OF PEAK, AND SHALL BE 3' FROM THE SUPPLY OR RETURN AIR STREAMS, AND EQUIPPED WITH A BATTERY BACK-UP. 7. ALL NEW CIRCUITS TO CONNECT TO EXISTING ELECTRICAL PANEL. 8. ELECTRICAL OUTLET HEIGHTS AS MEASURED FROM FINISHED FLOOR TO CENTERED LINE OF THE BOX TO BE: GENERAL : 16" GENERAL. KITCHEN : 44" AFF. BATHROOM : 39" AFF LAUNDRY ROOM : 36' AFF. EXTERIOR WATERPROOF : 12" AFF GARAGE GENERAL PURPOSE : 42" AFF. RANGE : 2" AFF 9. ALL TRIM PLATES & DEVICES TO BE GANGED, WHERE POSSIBLE. ELECTRICAL NOTES BEDROOM 1 10. ELECTRICAL SNATCHES TO BE AT 42" CENTERLINE ABOVE FINISHED FLOOR. 11 ELECTRICAL PLAN IS INTENDED FOR BID PURPOSES ONLY. ALL WORK SHALL BE DONE IN STRICT ACCORDANCE WITH THE NATIONAL ELECTRIC CODE, LATEST EDITION, BY A LICENSED ELECTRICAL CONTRACTOR WHO SHALL BE RESPONSIBLE FOR THE INSTALLATION & SIZING OF ALL ELECTRICAL, WIRING & ACCESSORIES. 12. SMOKE DETECTORS SHALL BE IN ACCORDANCE WITH R314.1 AND LISTED IN ACCORDANCE WITH UL 217. 13. PROVIDE AFCI'S (ARC -FAULT CIRCUIT INTERRUPTERS) COMBINATION TYPE INSTALLED TO PROVIDE PROTECTION OF THE BRANCH CIRCUITS IN ALL DWELLING UNITES PER NFPA 70 AND THE 2008 NEC. 14. PROVIDE TAMPER RESISTANT RECEPTACLES AS REQUIRED BY THE 2008 NEC, 406.11. 15. CARBON MONOXIDE PROTECTION: CARBON MONOXIDE ALARMS OR DETECTORS SHALL BE INSTALLED IN ALL DWELLING UNITES IN ACCORDANCE WITH FBC R315 AND NFPA 70. SUCH DEVICES SHALL BE LISTED BY THE APPROPRIATE STANDARD, EITHER ANSI/UL 2034, STANDARD FOR SINGLE AND MULTIPLE STATION CO ALARMS OR UL 2075, GAS AND VAPOR DETECTOR SENSOR, ACCORDING TO THE INSTALLATION. 15. CARBON MONOXIDE PROTECTION: CARBON MONOXIDE ALARMS OR DETECTORS SHALL BE INSTALLED IN ALL DWELLING UNITES IN ACCORDANCE WITH FBC R315 AND NFPA 70. SUCH DEVICES SHALL BE LISTED BY THE APPROPRIATE STANDARD. EITHER ANSI/UL 2034, STANDARD FOR SINGLE AND MULTIPLE STATION CO ALARMS OR UL 2075, GAS AND VAPOR DETECTOR SENSOR, ACCORDING TO THE INSTALLATION. i BEDROOM 2 BATH I CLOSET 1:P O AA , UVING II STORAGE PORCH ELECTRICAL PLAN SCALE 3/16": 1'-00" DINING CLOSET 16. R315.1.2 3 COMBINATION ALARMS: COMBINATION SMOKE/CARBON MONOXIDE ALARMS SHALL BE LISTED AND LABELED BY A NATIONALLY RECOGNIZED TESTING LABORATORY. `%till 17. KEEP ALL SMOKE DETECTORS MINIMUM OF 36" FROM BATHROOM DOORS. 18. IN NEW CONSTRUCTION, SMOKE DETECTORS SHALL BE HARDWIRED INTO AN A/C`%% yy ELECTRICAL POWER SOURCE AND SHALL BE EQUIPPED WITH A MONITORED BATTEQ46ACKLIP ,..; 19. BATHROOM EXHAUST FANS MUST VENT TO THE EXTERIOR OF THE BUILDING, *NTILATIPW - TO ATTIC SPACE ANDSOFFITS IS NOT ACCEPTAB LE. ' 20. ALL DOORS AND WINDOWS PROVIDING DIRECT ACCESS FROM THE HOME TO.7HQ6L CJ 1 SHALL BE EQUIPPED WITH AN EXIT ALARM COMPLYING WITH UL 2017 THAT HA& NWJ1111"O C SOUND PRESSURE RATING OF 85 DBA AT 10 FEET, AND EITHER HARDWIRED OR.OFJTFIE{n C4_ — PLUG-IN TYPE. THE EXIT ALARM SHALL PRODUCE A CONTINUOUS AUDIBLE WA0110L V D II * THE DOOR OR WINDOW ARE OPENED. ,J 21. ADD GFCI PROTECTION TO RECEPTACLES IN LAUNDRY ROOMS AND UTILITY Rg011B I•Qf JDWELLINGSWHEREINSTALLEDWITHIN6' IF THE OUTSIDE EDGE OF A SINK. THIS 1 ?uwo 7 INCLUDE THE RECEPTACLE INSTALLED FOR A WASHING MACHINE. RECEPTACLES 0RSHALLNOTBEREQUIREDONAWALLDIRECTLYBEHINDARANGEORSINKTOFULREQUIREMENTFORANOUTLETEVERY24'. THE WIDTH OF THE SINK OR RANGE IS INCLUDED IN THE SPACING OF THE OUTLETS UNLESS THE DISTANCE FROM THE SINK OR .toINCLUDED RANGE IS GREATER THE 12" FOR STRAIGHT COUNTER TOPS AND 18" FOR SINKS AND RANGE INSTALLED IN CORNER COUNTERS. 22. ELECTRICAL CONTRACTOR MUST VERIFY WITH THE SPECIFICATIONS FOR THE TYPE OF FIXTURE TO BE USED. LIGHT FIXTURES SHOWS ARE FOR LOCATION PURPOSES. NOTE EXISTING THE ELECTRICAL METER AND ELECTRICAL PANEL TO. REMAIN aw-RE JR" KITCHEN GF GO OC 0-, oeuc DW ELECTRICAL LEGEND Q RECESSED CEILING LIGHT WALL MOUNTED LIGHT FAN W/LIGHT FCb GROUND FAULT INTERRUPTER DUPLEX OUTLET TAMPER RESISTANT DUPLEX OUTLET 15 A. AFF 18" WATHERPROOF DUPLEX RECEPTABLES 220 V TAMPER RESISTANT DUPLEX OUTLET 15 A. UNDER COUNTER TAMPER RESISTANT DUPLEX OUTLET 15 M A. ABOVE COUNTER ELECTRIC METER LOCATION DELECTRIC PANEL IIIIIIIIIIJ DISCONNECT SWITCH A/C COMPRESOR W/CONCRETE PAD EXHAUST FAN BATHROOM TO THERMOSTAT WALL SNATCH 15 AMP. AFF 42" THREE WAY SWITCH 15 AMP. AFF 42" SMOKE DETECTOR & CARBON MONOXIDO COMBO 1/2 HOT, 1/2 TAMPER RESISTANT DUPLEX OUTLET 15 A. AFF 18" PENDANTS LIGHT PRE -HARED GARAGE DOOR OPENER Q PUSH BOTTON GARAGE DOOR OPENER GARBAGE DISPOSAL MOTOR SPOT LIGHT WATERPROOF 0° DOORBELL CHIME 0 d Wc IZEVISIONSI conn Z Cho LLI 4z J LLJ cl) i 0 N g ns N:; D C IDATE I06/18/2018 INUMBER I2018-0033 SHEET E1 PORCH MECHANICAL PLAN SCALE 3/16': 1'-00" MECHANICAL AND ELECTRICAL NOTES: 1- VERIFY EXACT LOCATION OF AIR HANDLER UNITS AND CONDENSING UNITS PROVIDE POWER AS REQUIRED TO EACH W/DISCONNECT AND PROVIDE A 110 V FOR USE DURING MAINTENANCE. 2- VERIFY LOCATION OF WATER HEATER WH) PROVIDE POWER W/DISCONNECT AS REOUIRED PROVIDE A 110 V OUTLET FOR SERVICE WORK IN AREA OF WATER HEATER IF NOT SERVICEABLE BY UNIT OUTLETS. g 4m En 12x61- 112x6 v 20 CFM BEDROOM 1120CFM 6 It 12 tOx10 11 '# 8X4 CFM CLOSET II AHU 12 6$ BEDROOM 2 I10x10 12 Of MECHANICAL GENERAL NOTES s i ' 1 1 II 12 >t! STORAGE 6 1.- INTENT OF THESE NOTES AND MECHANICAL NOTES ON DRAWINGS IS TO CLARIFY THE SCOPE 9•- DO NOT CUT STRUCTURAL MEMBERS WATb.0 R1 NWRITTENAPPROVALOFTHESTRUCTURALEN&NEEROFWORK. U ARCHITECT. ARRANGE FOR REPAIRS REOUIREI;:TOU2F.S E tiCONTRACTORTOVISITSITEANDVERIFYALL CLEARANCES BEFORE FABRICATION OF DUCTWORK AND OTHER WORK, BECAUSE OF DAMAGE CAUSED'IS ,A RE T PROVIDE ADDITIONAL OFFSET AND/OR CHANGES IN OF MECHANICAL INSTALLATIONS. C 10.- WALL MOUNTED THERMOSTAT TALL DzDUCTSIZESTOMEETFIELDCONDITIONSANDALLSHALL COORDINATE WITH ELECTRICAL, PLUMBING AT AN ELEVATION OF 54" ABOVE FINISHED FLW,-1. SUBCONTRACTORS BEFORE ANY CONSTRUCTION WORK. TOP UNLESS OTHERWISE NOTED ON DRAWINGS. L il4hL OF"' 2.- ALL SUPPLY AND RETURN DUCTWORK SHALL BE THE WALL MOUNTED THERMOSTAT SHALL BE COOR EXTERNALLY INSULATED.INSULATION SHALL HAVE AN WITH OTHERS TRADES FOR A NEAT APPEARANCE. "/I 11.- THE GENERAL CONTRACTOR IS RESPONSIBLEINSTALLEDMINIMUMTHERMALRESISTANCE (R) VALUE FOR ALL IC OF 6.0. ALL JOINTS SHALL BE SECURELY TAPED WITH TRADES INSTALLATION SCHEDULES. FIXED WORK SUCH AS 3" WIDE GLASS FABRIC TAPE WITH FOSTER DUCTWORK AND PLUMBING SHALL BE INSTALLED PRIOR TO MASTIC ANY TRADE WORK THAT CAN BE EASILY RELOCATED OR OR EQUAL. NOTE: ALL SUPPLY AND RETURN AIR DUCTS OFFSET SUCH AS ELECTRICAL CONDUITS, SMALL WATER 5'-0" AND GREATER FROM THE ROOFTOP UNIT MAY BE: LINES ETC. AT OWNER'S OPTION, MINIMUM R-6 RIGID FIBERGLASS 12.- ERRORS OR OMISSIONS: WHEN THE INTENT OF DUCT BOARD. FLEXIBLE DUCTS: EITHER SPIRAL ROUND ARCHITECT/ENGINEER WITH REGARD TO ANY DETAIL IS NOT SPRING STEEL WITH FLAMEPROOF VINYL SHEATHING, OR CLEAR, OR IS CAPABLE OF MORE THAN ONE CORRUGATED ALUMINUM. COMPLY WITH UL 181. INTERPRETATION, SUCH MATTERS WILL BE BROUGHT TO THE PROVIDE 1" THICK CONTINUOUS FLEXIBLE FIBERGLASS ATTENTION OF THE ARCHITECT/ENGINEER IN WRITING BEFORE SHEATH WITH VINYL VAPOR BARRIER JACKET. THE SUBMISSION OF BIDS, AND THE ARCHITECT/ENGINEER 3.- DUCT SHALL BE SECURELY SUPPORTED, HUNG OR SHALL MAKE CORRECTION OR EXPLANATION IN WRITING. SUSPENDED IN ACCORDANCE WITH SECTION 603 OF THE OTHERWISE, NO EXTRA CHARGE WILL BE ALLOWED FOR THE FLORIDA BUILDING CODE MECHANICAL 2014. WORK OR MATERIAL WHICH THE ARCHITECT/ENGINEER WILL 4.- IN GENERAL, PLANS AND DIAGRAMS ARE REOUIRE, PROVIDED THAT IT COMES WITHIN A REASONABLE SCHEMATIC ONLY AND SHOULD NOT BE SCALED. HVAC INTERPRETATION OF THE DRAWINGS AND SPECIFICATIONS. CONTRACTOR IS RESPONSIBLE FOR ANY ADDED 13.- PLANS AND SPECIFICATIONS ARE INTENDED AS AELECTRICALCOSTSWHICHMAYRESULTFROMGENERALDESCRIPTIONSOFTHEWORKTOBEPERFORMED. SUBSTITUTED EQUIPMENT. ALL ITEMS NOT SPECIFICALLY MENTIONED OR SHOWN, BUT5.- COORDINATE AIR DEVICE LOCATIONS WITH LIGHTING NECESSARY FOR THE COMPLETION OF THE INSTALLATION, FIXTURES. SHALL BE FURNISHED AND INSTALLED BY THIS CONTRACTOR. 6.- DUCT DIMENSIONS SHOWN ON DRAWINGS ARE THIS CONTRACTOR SHALL THOROUGHLY ACOUAINT HIMSELFCLEARINSIDEDIMENSIONS. WITH THE MECHANICAL, ARCHITECTURAL, STRUCTURAL AND7.- VERIFY VOLTAGE WITH ELECTRICAL BEFORE ELECTRICAL PLANS BEFORE SUBMITTING HIS FINAL BID. ORDERING EQUIPMENT. 14.- NO ADDITIONAL COMPENSATION WILL BE ALLOWED DUE8.- ALL MECHANICAL WORK SHALL MEET ALL THE TO THE CONTRACTOR'S FAILURE TO FAMILIARIZE REQUIREMENTS OF THE *FLORIDA MECHANICAL CODE HIMSELF/HERSELF WITH THE PLANS. 2014 5TH EDITION'. KITCHEN PORCH 12x6 Ou DINING 120 CFM O 1CFM1 # # 120CFM 12061001CFM MM MECHANICAL LEGEND R HEAT PUMP SPLIT SYSTEM. MANUF. SELECTED BY OWNER. SIZE OF UNIT SPECIFIED ON ENEGY CALCULATIONS TRANSITION DUCTBOARD BOX. SIZE AS REOUIRED PER MECHANICAL CONTRACTOR TO ACCOMODATE FLEX DUCT WORK. X SIZE OF SUPPLY AND RETURN GRILLS. END DUCTBOARD BOX. SIZE AS REOUIRED PER MECHANICAL CONTRACTOR TO ACCOMODATE FLEX DUCT WORK. SUPPLY GRILL WHITE ALUMINIUM UNLESS SPECIFIED OTHERWISE. SIZE OF DUCTWORK. DIRECTION OF AIR F RETURN GRILL WHITE ALUMINIUM UNLESS SPECIFIED OTHERWISE. OTHERMOSTAT LOCATION SHOWN ON LAYOUT SUPPLY FLEX DUCTWORK W/R-6 INSULATION. RETURN FLEX DUCTWORK W/R-6 INSULATION. 9 F IL_ WO REVISIONSI00 ^ zo Cn a C o Ll1 Ld A a O N g Y;1EDATE06/ 18/2018 NUMBER 2018- 0033 SHEET M1 A/C COMPRESSOR INSTALLATION ANCHORAGE OF APPLIANCES. APPLIANCES DESIGNED TO BE FI%ED IN POSITION SHALL BE FASTENED OR ANCHORED IN AN APPROVED MANNER. STRAPPING SHALL BE AT POINTS WITHIN THE UPPER ONE-THIRD AND LOWER ONE-THIRD OF THE APPLIANCE'S VERTICAL DIMENSIONS. AT THE LOWER POINT, THIS STRAPPING SHALL MAINTAIN A MINIMUM DISTANCE OF 4 INCHES 102 MM) ABOVE THE CONTROLS. PER M13072. GOUND-MOUNTED UNITS GROUND -MOUNTED UNITS FOR GROUP R3 RESIDENTIAL APPLICATIONS MANY BE ANCHORED WITH #14 ACREWS NTH GASKETED WASHERS ACCORDING TO THE FOLLOWING. 1. FOR UNITS WITH SIDES LESS THAN 12 INCHES (305 MM), ONE SCREW SHALL BE USED AT EACH SIDE OF THE UNIT. 2. FOR UNITS BETWEEN 12 AND 24 INCHES (305 AND 610 MM), TWO SCREWS SHALL BE USED PER SIDE. 3. FOR UNITS BETWEEN 24 AND 36 INCHES (610 AND 9144 MM), THREE SCREWS SHALL BE USED PER SIDE. 4. FOR UNITS GREATER THAN 36 INCHES OR 5 TONS (9144 MM AND 18 KW), ANCHORAGE SHALL BE DESIGNED IN ACCORDANCE WITH SECTION M1307.3. NOTES: 1. CORROSION PROTECTION. BUILDINGS LOCATED WITHIN 3.00 FEET (914 400 MM) OF THE OCEAN SHOULD UTILIZE NONFERROUS METAL, STAINLESS STEEL OR STEEL WITH MINIMUM G-90 HOT -DIP GALVANIZED COATING EQUIPMENT STANDS AND ANCHORS AND STAINLESS STEEL SCREWS. 2. STRAPPING. JOB -SITE STRENGTHENING OF FAN COWLINGS AND VENT HOODS IS RECOMMENDED. TWO OR FOUR STAINLESS STEEL CABLES ARE RECOMMENDED, DEPENDING ON DESIGN WIND CONDITIONS. ALTERNATIVELY, ADDITIONAL, HEAVY STRAPS CAN BE SCREWED TO THE COWLING AND CURB, A/C COMPRESSOR CONCRETE PAD TYP. FRAMING @ EXTERIOR DOOR OPENING CRIPPLE STUDS 0 16' O.C. BETWEEN HEADER do TOP PLATE WHEN APPLICABLE W/SIMPSON SP1 AND SIMPSON SP2 TOP AND BOTTON EACH STUD. 2) 2X12 No. 2 SYP HEADER W/7/16' OSB. SPACER UNLESS NOTED OTHERWISE ON PLANS 2) FULL LEGHT STUDS AT EACH SIDE OF OPENING UNLESS NOTED OTHERWISE ON PLANS, TRIMMER STUDS: 1) REQ. EACH SIDE OPENNINGS UP TO 6'-0' WIDE 2) REQ. EACH SIDE OPENNINGS 6' TO 12'-0' WIDE. SEE PLAN FOR ADDITIONAL SECTION REQUIREDED. 2) 10d TOENAILS OR (2) 16d ENDNAILS EACH STUD. NOTE : SEE PLAN SHEAR AND/OR UPLIFT FORCES. EXTERIOR WALL AND FLOOR SHEATHING NAILING PATTERN DETAIL EXHAUST FAN DETAIL BATH r 4'-0• -- 8d NAILS OR EQUIVALENT PNEUMATIC NAILS 0 0 0 0 0 0 0 0 0 0 0 0 0 BLOCKING REQUIRED: PROVIDE 0 0 2'x4• BLOCKING IN THE FIRST0 0 0 0 THREE FRAMING SPACES AT 48" 0 0 0 o O.C. REMAINDER TO BE BLOCKED 0 0 AT 96' O.C. 0 0 0 FASTENING: FASTEN FLOOR 0 0 XQR SHEATHING TO FRAMING AND 0 0 0 0 0 o PLYWOOD (SEE BLOCKING WITH 8d COMMONS OR 8d HOT DIPPED GALVANIZED NAILS 0 0 SECTION) AT THE FOLLOWING SPACING: 0 0 o c 1) 4' ON CENTER AT ALL0 0 o PANEL EDGE FRAMING OR 010 0 0 0 o INTERMEDIATE SUPPORT o FLOOR JOIST) 0 0 2) 12" ON CENTER AT ALL o INTERMEDIATE FRAMING 0 0 OR 0 o INTERMEDIATE SUPPORT 0 0 NAIL SPACING FLOOR JOIST) 0INTERMEDIATE 0 o 0 o 0 o 0 0 0 0 0 0 0 0 0 0 0 0 0 0 FRAMING EXI I. FAN %V.,WLATIIEK PROOF TOP ROOF, PIECIISUBCOLSRACfOR TYP. c i" METAL DUCT fHHOUGH ROOF CRIIJIVG LINE TYP. DOOR ELEVATION i-3 - PRE -HUNG IN WOOD FRAME 1-1/2" PAIR BUTT HINGES BRASS O0 1-3/8' HOLLOW CORE WOOD DR. io PAINT GRADE BIRCH VENEER LEVER HANDLE (H.C.) UNDERCUT 1" 9 0 REVISIONSI IDATE06/18/2018 INUMBER I2018-0033 SHEET D1 REPAIR CEILING TRUSSES CUT— NOTCHED USE 2'x6"x8' OR 2'x4'x8' SYP #2. 3-5 NAILS DIAGONAL PATTERN W/3 NAILS PLUMB IN LINE. MUST USE 10dx3". EXTERIOR WOOD FRAME TYPICAL WALL CONNECTOR LEGEND: SIMPSON SP4 W/6-10d 0-1/2' EACH SIDE OF STUD 32' O.C. ON THE TOP AND BOTTON. SIMPSON LSTA24 EACH SIDE. 20 g. W/18-10dx1-1/2" TOTAL PT SILL W/}' ANCHOR BOLTS • 32- O.C. OR USE NAILS 12d • 6' O.C. IN TWO LINE CONNECTED TO EXISTING FLOOR JOIST D WINDOW & DOOR JACK TABLE (BOTH SIDES). PROVIDE JACKS ® EACH END AS FOLLOWS: 2) WHEN OPENINGS ARE GREATER THEN 4'00- 3) WHEN OPENINGS ARE GREATER THEN 6'00- 4)WHEN OPENINGS ARE GREATER THEN 8'00- BUT LESS THAN 10'00' 2-2'x4 A2 SYP HEADER UNLESS NOTED OTHERWISE. 2-2'x4- (02 SPF) TOP PLATES W/ 12d 6' O.C. MINIMUM SPLICE 48' 2'x4' (#2 SPF) STUDS AT 16' O.C. 2'x4' SYP #2 BRACE MAX ® 48' O.C. W/(3) 10dx3" NAILS EA. END ONLY THE LIVING AREA CEILING. EXISTING ENGINEERING TRUSS TO REMAIN EXISTING 2'x6' OR 2"x4' SYP #2 CEILING TRUSS WILL BE CHANGED OR REPAIRED AS CONSIDERED BY G.C. EXISTING FLOOR JOIST EXISTING KNACK PLATE AND STRUCTURAL SUPPORT TO REMAIN. WALL NAILING SCHEDULE FOR DRYWALL L SPLICE MIN. 48"A 11---Ir T N- -- -III----T--T--T II 11 II III fF III I II 11 11 II 11 11 IIL II 11 11 11 111 II 1 11 II 11 II 11 11 111 1 1 11 II II II C 11 11 III 1 I 11 II II II II II III III 1 11 II II II 11 It It III III 1 11 It IIOPENMItUL1. III III U I II II111111I 11 11 11 I III III II 1 II II n fl n JL__UL_...Jl._ III III U 11 II I 1 1 1 m w u 1 JL__JL_—! 9 111-r--r-- III p II II I 11 III I I II III u II II I SOLID BLOCK II 11 II 111 I I II III 11 II II I ALL SHEATHING II II 11 11 111 1 11 111 It 11 11 1 EDGES TYR er=—'t-_==,!= t. FLOOR SYSTEM 111 1 11 111 11 11 11 1 III 1 1 11 111 11 11 11 1 2k8" RIBBON aN BLOCKING BETWEEN FLOOR SYSTEM S"' = NAIL 4• SPACING TV" P.T. BASE PLATE VaL SINGLE NAIL EDGE SPACING I 8 1 it* — DOUBLE NAIL EDGE SPACING A NAIL AT BASE 2 ROWS @ 4" O.C. W/8d COMMOM NAIL B NAIL AT TOP PLATE 2 ROWS @ 4" O.C. W/8d COMMOM NAIL C NAIL OPENING PERIMETER @ 3" O.C. W/8d COMMOM NAIL D NAILINT. AT V' O.C. W/8d COMMOM NAIL E STAGGER ALL VERT. JOINTS & NAIL @ 4" O.C. W/8d COMMON NAIL F NO SPLICE @ HEADER -NAILSHEATHING TO HEADER W/8d COMMOM NAIL @ 4" O.C. SELF -ADHERED FLASHING FLANGED WINDOW SELF -ADHERED FLASHING DOOR WITH DECK -SECTION EXTERIOR A SELF -ADHERED FLASHING EXTERIOR DOOR WITH DECK FLASHING INSTALLATION AFTER FOLD UP WEATHER DOOR ROUGH WEATHER RESISTIVE BARRIER RESISTIVE BARRIER OPENING INSTALL TEMPORARILY SELF -ADHERED WEATHER RESISITIVE CURE WEATHER EXTERIOR FLASHING JAMB & r BARRIER TAPE RESISITIVE 3/4'-1' BEAD OF CONST. SHEATHING HEAD FLASHING, FLANGED1EXTERIOR SHEATHING BARRIER ADHESIVE TO BE APPLIED SEE WINDOW. SEE WOOD FRAME UNDER THRESHOLD OF DOOR DETAIL WP01 WEATHER CONSTRSELF- ADHERED AND RETURN UP JAMB 6". SECTION A -SELlRESISITIVEFLASHINGBYUSELIQUIDNAILBRANDORDETAILWP02 SELF -ADHERED BARRIER LAPPING DOWN OVER EQUAL WEATHER PROOF FLASHING, EXTEND RIM JOIST AND UP CAULKING A MINIMUN 6" SELF -ADHERED WALL BY 6". SELF -ADHERED VERTICALLY FROM FLASHING FLASHING BOTTOM OF SUB OOR THRESHOLD HEAD FLASHING TIE-IN INSTRUXTIO 1. Cut, fold up & temporarily secure weather resistive barrier above header to 1 SEAL TOPS OF JOISTS UNDER RIM JOIST 1 SELF ADHERED 1 allow for flashing installation 2 DECKING 82 FLASHING o 2 2. Self-odhered flashing plus head flashing under weather resistive barrier EXTERIOR SEAL TOPS -OF 3. Fold weather resistive barrier bock over WP 01 SHEATHING WP02 JOISTS UNDER WP05 head flashing and seol with tape DECKING 8 PLUMBING GENERAL NOTES: 1. ; ' SERVICE FROM METER TO RESIDENCE FOR 2 BATHS. 1' SERVICE FROM METER TO RESIDENCE FOR 2-1/2 OR MORE BATHS. 2. WATER PIPE IS CPVC rLOVIGUARD GOLD, SCHEDULE 4Q " FROM j ' PIPING. 3. DOMESTIC COLD WATER MIN. 12" BELOW GRADE. VERIFY EXACT LOCATION BEFORE STARTING. 4. DOMESTIC COLD WATER SHUT-OFF VALVE IN VALVE BOX MARKED 'WATER'. 5. SANITARY MIN. 12" BELOW GRADE. VERIFY EXACT LOCATION BEFORE STARTING WORK. 6. FOR CONT. OF PIPING AND SIZE SEE SANITARY WASTE AND VENT RISER. I. j " CW do HW UP TO PLUMBING FIXTURE(S). a j " CW & HW DOWN TO WATER HEATER TANK. S. j " SAFETY PAN DRAIN PIPE FROM WATER HEATER TERMINATION OF SAFETY PAN DRAIN TO EXTERIOR OF UNIT. PAN AND DRAIN NOT REQUIRED WHEN WATER HEATER IS BELOW FINISH FLOOR. 10. ALL DWV - (1 2", 3", 4") TO BE PERM ACHORD-MATERIAL 11. ALL DWV - DRAIN FITTINGS TO BE PERMACHORD MATERIAL SCHEDULE 40 PIPING do FITTINGS 12. GLUE (TYP.) - OATEY PURPLE PRIMER 13. CW WALL CONNECTING TO WATER SERVICE OF CITY 14. SANITARY WILL CONNECTING TO DISPOSAL SYSTEM (SEPTIC TANK AND DRAIN FIELD) OR TO THE SERVICE OF CITY (SEWER). DATE 06/18/2018 NUMBER 2018-0033 SHEET D2 REPAIR CEILING TRUSSES CUT- NOTCHED 00' 1 71 USE 2'x6'x8' OR 2'x4"x8' SYP #2. 3-5 NAILS DIAGONAL PATTERN W/3 NAILS PLUMB IN LINE. MUST USE 10dx3'. EXTERIOR WOOD FRAME TYPICAL WALL CONNECTOR LEGEND: SIMPSON SP4 W/6-10d 0-1/2' EACH SIDE OF STUD O 32' O.C. ON THE TOP AND BOTTOM. SIMPSON LSTA24 EACH SIDE. 20 g. W/18-10dxt-1/2' TOTAL PT SILL W/}' ANCHOR BOLTS O 32' O.C. OR USE NAILS 12d O 6' O.C. IN TWO UNE CONNECTED TO EXISTING FLOOR JOIST D)WINDOW & DOOR JACK TABLE (BOTH SIDES). PROVIDE JACKS O EACH END AS FOLLOWS: 2) WHEN OPENINGS ARE GREATER THEN 4'00- 3) WHEN OPENINGS ARE GREATER THEN 6'00- 4)WHEN OPENINGS ARE GREATER THEN 8-00- BUT LESS THAN 10'00' 2-2'x4 #2 SYP HEADER UNLESS NOTED OTHERWISE. 2-2'x4' (02 SPF) TOP PLATES W/ 12d 6' O.C. MINIMUM SPUCE 48' 2'x4' (#2 SPF) STUDS AT 16' O.C. SELF -ADHERED FLASHING FLANGED WINDOW 2"x4' SYP #2 BRACE MAX O 48" O.C. W/(3) IOdx3' NAILS EA. END ONLY THE LIVING AREA CEILING. EXISTING ENGINEERING TRUSS TO REMAIN EXISTING 2"x6' OR 2"x4" SYP y2 CEILING TRUSS WILL BE CHANGED OR REPAIRED AS CONSIDERED BY G.C. EXISTING FLOOR JOIST EXISTING KWICK PLATE AND STRUCTURAL z N WALL NAILING SCHEDULE FOR DRYWALL 06 e 2-SPF CONST GRADE TOP SPLICE MIN. 48"AT PL T N $ x T)r0 o II 11 II 111 all, poil111111IIix (V U, u n n nl 111 11 a u LL_ W : + cunn L o m I n n u — u u a 1 Z ( 11 11 11 I 111 C 111 11 1 II 11 •, JL__JL__JI__ coil SOLID BLOCK 11 11 II 11 III I II III II II II I 111 I II III 11 II 11 I N V ALL SHEATHIN u o u a w 1 n w n o u 1 ZJ`-=="---1-` 111 I II III 11 II II I PEDGESTYP. FLOOR SYSTEM 1-----•- -- --- aN 2 k8" RIBBO BLOCKING A 2'k4" P.T. BASE PLATE C1g „ BETWEENFLOORSYSTEMA 5 9/9• /8• Z S" = NAIL 4 314. SPACING, 11 F yr SINGLE NAIL EDGE SPACING S DOUBLE NAIL EDGE SPACIN A NAIL AT BASE 2 ROWS @ 4" O.C. W/8d COMMOM NAIL P B NAIL AT TOP PLATE 2 ROWS @ 4" O.C. W/8d COMMOM NAIL C NAIL OPENING PERIMETER @ 7 O.C. W/8d COMMOM NAIL c D NAILINT. AT 6" O.C. W/8d COMMOM NAIL E STAGGER ALL VERT. JOINTS & NAIL @ 4" O.C. W18d COMMON NAIL F NO SPLICE @ HEADER -NAIL SHEATHING TO HEADER W/8d `c COMMOM NAIL @ 4" O.C. EVISIONS SELF - ADHERED FLASHING EXTERIOR SELF -ADHERED FLASHING EXTERIOR DOOR WITH DECK -SECTION A DOOR WITH DECK FLASHING INSTALLATION AFTER FOLD UP WEATHER DOOR ROUGH WEATHER RESISTIVE BARRIER RESISTIVE BARRIER OPENING INSTALL TEMPORARILY SELF —ADHERED WEATHER RESISITIVE CURE WEATHER EXTERIOR FLASHING JAMB do BARRIER RESISITIVE 3/4"-1' BEAD OF CONST. SHEATHING HEAD FLASHING, TAPE EXTERIOR SHEATHING BARRIER ADHESIVE TO BE APPLIED SEE FLANGED WINDOW. SEE WOOD FRAME UNDER THRESHOLD OF DOOR DETAIL WPO1 WEATHER CONSTRSELF— ADHERED AND RETURN UP JAMB 6". SECTION A —SE LlRESISITIVEFLASHINGBYUSELIQUIDNAILBRANDORDETAILWP02SELF —ADHERED BARRIER LAPPING DOWN OVER EQUAL WEATHER PROOF FLASHING, EXTEND RIM JOIST AND UP CAULKING A MINIMUM 6" SELF — ADHERED WALL BY 6". SELF —ADHERED VERTICALLY FROM FLASHING FLASHING BOTTOM OF SURF OOR THRESHOLD HEAD FLASHING TIE—IN INSTRUXTIO 1. Cut, told up & temporarily secure weather resistive barrier above header to SEAL TOPS OF JOISTS UNDER RIM JOIST 1 SELF allow for flashing installation 2 DECKING 2 ADHERED FLASHING m 2 2. Self—odhered flashing plus head flashing under weather resistive barrier 3. Fold weather resistive barrier bock over WP01 EXTERIOR SHEATHING WP02 SEAL TOPS OF JOISTS UNDER WP05 head flashing and seal with tape DECKING PLUMBING GENERAL NOTES: 1. j " SERVICE FROM METER TO RESIDENCE FOR 2 BATHS. 1" SERVICE FROM METER TO RESIDENCE FOR 2-1/2 OR MORE BATHS. 2. wAto PIPE IS a?vc n ovimImm o=, scHEDULE 4a. " FROM j " PIPING. 3. DOMESTIC COLD WATER MIN. 12' BELOW GRADE. VERIFY EXACT LOCATION BEFORE STARTING. 4. DOMESTIC COLD WATER SHUT—OFF VALVE IN VALVE BOX MARKED 'WATER". 5. SANITARY MIN. 12" BELOW GRADE. VERIFY EXACT LOCATION BEFORE STARTING WORK. 6. FOR CONT. OF PIPING AND SIZE SEE SANITARY WASTE AND VENT RISER. 7. CW & HW UP TO PLUMBING FIXTURE(S). S. " CW & HW DOWN TO WATER HEATER TANK. 9. j " SAFETY PAN DRAIN PIPE FROM WATER HEATER TERMINATION OF SAFETY PAN DRAIN TO EXTERIOR OF UNIT. PAN AND DRAIN NOT REQUIRED WHEN WATER HEATER IS BELOW FINISH FLOOR. 10. ALL DWv - (1 2'. 3'. 4") TO BE PERMACHORD MATERIAL 11. ALL DWV — DRAIN FITTINGS TO BE PERMACHORD MATERIAL SCHEDULE 40 PIPING do FITTINGS 12. GLUE (TYP.) — OATEY PURPLE PRIMER 13. CW WILL CONNECTING TO WATER SERVICE OF CITY 14. SANITARY WILL CONNECTING TO DISPOSAL SYSTEM ( SEPTIC TANK AND DRAIN FIELD) OR TO THE SERVICE OF CITY (SEWER). IDATE I 06/18/2018 INUMBER I 2018-0033 SHEET D2 MUMS RECORD COPY Florida Building Code Online 4 Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Emall Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Florida Engineer or Architect Name who developed the Evaluation Report Florida License Quality Assurance Entity Quality Assurance Contract Expiration Date Validated By Certificate of Independence Custom Window Systems Inc. 1900 SW 44th Avenue Ocala, FL 34474 352)368-6922 Ext245 kpine®cws.cc Kevin Pine kpine®cws.cc ay Lathrop 1900 SW 44th Ave Ocala, FL 34474 352) 368-6922 Ext 291 jlathrop®cws.cc Arturo Monteverde 1900 SW 44th Ave Ocala, FL 34474 352) 368-6922 Ext 221 amonteverde®cws.cc Exterior Doors Swinging Exterior Door Assemblies Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Lucas A. Turner PE-58201 Keystone Certifications, Inc. 07/21/2020 Steven M. Urich, PE Validation Checklist - Hardcopy Received ELIO R6 GOI EvalReoort179F ndf Referenced Standard and Year (of Standard) Standard Year ASTM E283 2004 ASTM E330 2002 ASTM E331 2009 Equivalence of Product Standards Certified By hMWArwwJWWaWiding.orglp W eppod.eVx?pammawGEVXOwogwymvA)011045csMGIoEpop8Yr%21fAksnA%3d 112 2/23/P018 Florida Building Code Online Sections from the Code Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Summarw of PrnAuraa Method 1 Option D 09/26/2017 09/29/2017 10/03/2027 12/12/2017 Ft. a>t Model, Number or Name Description 161.1 Guardian Hinged Door Guardian Hinged Door w/Glazed Insert. Limits of use Approved for use In HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +40/-40 Other: Not for use In HVHZ. Primarily used with Screen Rooms. Installation Instructions FL161_gjt jL[WS-176F.odf Verified By: Lucas A. Turner 58201 Created by Independent Third Party: Yes Evaluation Reports FjW_U_&—EX4&Qort176F Ddf Created by Independent Third Party: Yes 161.2 Guardian Hinged Door Guardian Hinged Door w/Solid Core. Limits of Use Approved for use In HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +40/-40 Other: Not for use in HVHZ. Primarily used with Screen Rooms. Installation Instructions FL161 S-242E.Ddf Verified By: Lucas A. Turner 58201 Created by Independent Third Party: Yes Evaluation Reports FL161_B _a_FvaIgeQ2rt242F-Wf Created by Independent Third Party: Yes 9o[Y, Next I :: 2601 8181E Stone Road Tallahassee ch 72199 Phone: OSO-487.1824 The State ofRorlda Is on AA/EEO employer. QWrloht 2007.2011 Stare of Flerld :: Orivaer Statement :: AccossIbIllIX Statement :: Refund Stw am nt Under Florida law, email addresses are public records. If you do not went your a -mall address released In response to a public -records request, do not send electronicmailtothisentity. Instead, coned the office by phone or bytndltlonal mail. If you haveMY questions, please contact 850.487.1395. -pursuant to Section455.275(1). Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Depart 0.t with an email address0they haveone. The !mails provided may be used for official communication with the licensee. However email addresses are public record. U you do not wishto supply a personaladdress, please provide the Department with an email address which can be made available to the pubic. To determine If you are a licensee under Chapter 45S, F.S., Please dick br . Product Approval Accepts - OEM IWORNE Credit Card Safe 9 44 h"s //www.floridabtdlding.tuglpr/pr app ciliaaspic?paramawGEVXGwt q"MngAbt1045=MGloEpop8Yr%2ffAkv A%3d 2J2 or p lb TABLE OF CONTENTS GENERAL NOTES & ELEVATIONS........I SECTION VIEWS.....................................2 BOM A EXTRUSIONS ..............................3 ANCHOR SCHEDULE 6NOTES.............4 INSTALLATION DETAILS ........................5 PRIME DOOR - NON -IMPACT SOLID CORE) GIUMu untva• 1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WIT" THE FLORIDA BUILDING CODE (FBC). CURRENT EDITION. 2. GLAZING OPTIONS: NONE • SOI CORE 3. CONFIGURATIONS: OVTSWRIG, LEFT OR RIGHT HINGED. 4. DESIGN PRESSURE RATING: NEGATIVEOF -SIGN LOADS BASED ONTESTED PRESSURE POSITIVE DESIGNLOADSBASED ON TESTED PRESSURE. WATER INFILTRATION TEST PRESSURE 5. ANCHORAGE: THE 331*% STRESS INCREASE FINS NOTBEEN USEDINTHEDESIGNOFTHISPRODUCT. SEE SHEET 5 FOR ANCHOR DETAILS. WNDLOAD DURATION FACTOR Cd-1.5WAS USED FOR WOOD ANCHOR CALCULATIONS. 5, NOT APPROVED FOR IMPACT RESISTANCE. IMPACT PROTECTIVE SYSTEM IS REQUIRED IN WINDBORNE DEBRIS REGION. T. ALL FRAMES SCREWED TOGETHER. SMALL JOINT SEAM SEALANT USED AT ALL FRAME JOINTS. MAX. UNIT SIZE DESIGN PRESSURE RATING IMPACT RATING 37-1/4' x 81' 40 PSF NONE Lucas Tumor 2017-M25 16:09+20:00 WINDOW SYSTEMS 0 INN SW NTH AVE. OCALA. FLORIDA 3N74 WWW.CWS.CC 1000 ALUM. GUARDIAN DOOR NON -IMPACT x2 9115=17 LUCAS A. TURNER, P,E, FL PE N S5201 239 JABARA AVE, NORTH PORT, FL 34258 PH. 841d80.1574 affralgamProw— GENERAL NOTES AND ELEVATIONS tokvm BY: CAM; AAJ MUM CWS-242 y E SHEET 1:15 1 OF 5 WINDows Tsr 1 1 1900 SW 44TH AVE. OCALA. FLORIDA 3447413 INTERIOR 9 W WW.CWs.CC 1000 ALUM. 9GUARDIAN DOOR Q NON -IMPACT 19 19 3 14 1 3; 0; IM SECTION VIEW 9 6 HA 6 d G U to Mgt $ i INTERIOR lnni'd O= y Z0wy 658201 '? SO OTATE Oi 4• tFSs< R 1' `'rO• t9Op/ oNA;`, z 9/ 15/2017 10 7 LUCAS A. TURNER, P.E. FL PE 9 S9201 5 1239 JABARA AVE. NORTH PORT, FL 3428E PH. 941:tIl74 1193) THRESHOLD DESCji RIPTIONMAX. POS. OP i ao I rwu of a 1.1/1 W 7 E LINE ITEMS NOT USED: 2.4, 20.22, 27, 30 6 CORNER KEY. S•1002 UY4, V,6- 1 1L16' 1 OUTSWING HEAD S 1377 215118' --{ 5 L 1/16• STANDARD THRESHOLD S•1186 NOTE: ALL ALUMINUM EXTRUSIONS ARE 6063•T6 UNLESS OTHERWISE NOTED. 4 DOOR CORE-1+1001 r— 2 3A8' Ills' i 1 tl18' l 3 LOUTSWING JAMB S•1374 Fes-- 3 318' 718' I 7 BUMPER THRESHOLD &1126 A OUTER FRAME ASSEMBLY 1, PANELFRAME ASSEMBLY 2 5A8' 1l18' 1 3/16' am__I ADJUSTABLE SWEEP S4300 3 7/16' 13/18' 8 1— SADDLE THRESHOLD S•1193 THRESHOLD DESCRIPTION IAAIt. POS. DP 1120 BUMPER THRESHOLD 1188 A RES 40 1900 SW 44TH AVE. OCALA. FLORIDA 3M74 wwW.CWS.CC1000 ALUM. GUARDIAN DOOR NON - IMPACT lxz 9/ 15/2017 LUCAS A. TURNER. P.E. FL PE 0 SS201 1239 JABARA AVE. NORTH PORT. FL 34288 PH. 941J80.1S74 BOM AND EXTRUSIONS I AAJ @ CWS• 242 NOTE: INSTALLATION w/1126 OR 1193 THRESHOLDS ONLY ALLOWED WHERE NO WATER INFILTRATION RESISTANCE IS NEEDED. .2 03/ 13/M9 E SHEET 3OF6 12 3/41 MAX O.C. (TYP.) 6' MAX (TYP.) SEE NOTE 2 WINDOW fYSTElp 6' MAX. (TYP.) 1900 SW "THAVE. OCALA. FLORIDA 34474 WWW.CWS.CC INSTALLATION ANCHOR 1000 ALUM. GUARDIAN DOOR NON -IMPACT 1r MAX. O.C. mP-) $ a w INSTALLTWO88ANCHORSTHRU2s = K STRIKE PLATE ANDOEADSOLT STRIKE 3 ; O m PLATE INTOSUBSTRATE (TYP.) W 2 0= INSTALLONE09ANCHORTHRUpz! fiZ Z a EACH HINGEINTOSUBSTRATE (1'YP.) OF;6 F tz on w Wog$ HeSB201 a OTATS OF NOTES: 1, INSTALL ONE ANCHOR AT EACH INSTALLATION LOCATION. SILL ANCHOR SPACING SAME AS HEAD. 2. SHIM AS REO AT EACH INSTALLATION ANCHOR USING LOAD BEARING SHIMS. MAX ALLOWABLE SHIM STACK TO BE 114'. USE SH045 WHERE SPACE GREATER THAN 1/16' IS PRESENT. LOAD BEARING SHIMS SHALLBECONSTRUCTEOOFHIGHDENSITYPLASTICORBETTER. WOOD SHIMS ARE NOT ALLOWED. XZ 3. ANCHOR TYPE, SIZE, SPACING AND EMBEDMENT SHALL BE AS SPECIFIED IN THESE DRAWINGS, SEE TABLE 1, SHEET S. 9/ISf2017 LUCAS A. TURNER, P.E. FL PE 0 59201 1239 JABARA AVE. 4. ALL INSTALLATION ANCHORSMUST BE MADE OF ORPROTECTED WITH A CORROSION RESISTANT MATERIALOR COATING. DISSIMILAR METALS OR MATERIALSIN CONTACT WITH PRESSURETREATED WOOD MUSTBEPROTECTEDTOPREVENTREACTION. 5. INSTALLATION ANCHORS SHALL BE IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS, AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUMSPECIFIEDINTABLE1, SHEET S. NORTH PORT, FL 34298 PH. 941380. 1S74 ANCHOR SCHEDULE AN 8. ANCHOREMBEDMENTTOSUBSTRATESHALLBEBEYONDWALLDRESSINGORSTUCCO. 7. A MINIMUM CENTER•TOCENTER SPACING SHALL BE MAINTAINED BETWEEN ALL FASTENERS: 3' FOR MASONTRY, 1-FOR W000 AND METAL NOTESORAWN! AAJ 03/ 13/09 S. WOODORMASONRYOPENINGS, BUCKS AND BUCK FASTENERS SHALL BE PROPERLY DESIGNED BY THE ARCHITECT OR ENGINEER OF RECORD AND INSTALLED TO TRANSFER WIND LOADS TO THE STRUCTURE. SUBSTRATESSHALLMEETTHEMINIMUMSTRENGTHREQUIREMENTSASSHOWNINTABLET, SHEETS. CONCRETE AND MASONRY SUBSTRATES MAY NOT BE CRACKED. 9. SEALING AND FLASHING STRATEGIES FOR OVERALL WATER RESISTANCE OF INSTALLATION SHALL BE DONE BY OTHERS FOLLOWING THE CURRENT VERSION OF THE REFERENCE DOCUMENTS: FMAIAAMA 100(FIN WINDOWS), FMA/AAMA 200(FLANGE WINDOWS), FMANVOMA 25%BOX WINDOWS), FMA/AAMWOMA 300(EXTERIOR DOORS) r, CWS- 242 E 1:20 - SHEET 4OF5 TYPICAL HEAD ANCHORAGE MIN. EMBEDMENT — SEE TABLE 1 SUBSTRATE BY OTHER; SEE TABLE 1 PERIMETER SEALANT — BYINSTALLER INSTALLATION ANCHOR SEE TABLE 1 SEALANT BEHIND FLANGE BY INSTALLER MIN. EDGE GIST. SEE TABLE 1 114' MAX. SHIM INTERIOR INSTALLATION ANCHOR SEE TABLE 1 SEAL OR SET IN CONCRETE OR MASONRY PERIMETER SEALANT BY INSTALLER T MIN.EMSEOMENT SUBSTRATE BY OTHEe e SEE TABLE 1 SEE TABLE 1 j e - MIN. EDOE DIST. SEE TABLE 1 VERTICAL SECTION 5 TYPICAL SILL ANCHORAGE TABLE I: APPROVED INSTALLATION FASTENERS SUBSTRATE TYPE ANCHOR TYPEWN. EUBEDUEINT MIN. EDGE GIST. CONCRETE ( LO KSI MIN.) 3116• RW TAPCON 1• 1.1/6• CONCRETE ( 2.65 KSI MIN.) 311W ELCO LILTRACON 1• 1• 2XMIN. SOUTHERN PINE (0-0.55) 010 WOOD SCREW I-w 1/2• 0. 04r ALUM. (6063-T5 MIN.) OR 0. 045' STEEL (33 KSI MIN.) 010 GRADE 5 SELF -TAPPING / ORlIlM SCREW FULL THREAD THRU 0.04r 1/I MW40E AND STRKE ILA ANCHO 2XMIN. SOUT ERN POLE 0. OB WOOD SCREW t 7/6' MIN. EDGE OIST. IWD SW N4TH AVE. SEE TABLE 1 OCALA. FLORIDA 34474 W WW.CWS.CC RITERIORIra- MAX. SHIM HINGE/ STRUMPLATE HINGEISTRIKEPLATE 1000 ALUM. MIN. EMBEDMENT MIN. EDGE DISTANCE GUARDIAN DOOR SEETABLE1SEETABLE1NON4MPACTMIN. EMBEDMENT z ei HINGEISTROM PLATE SCREW SEE TABLE 1 a SEE TABLE 1 i d a:3 INSTALLATION ANCHOR SUBSTRATE BY OTHERS p SEE TABLE 1 SEE TABLE 1SEALANT BERNDS FLANGE BY INSTALLER BY I ALLEPERIMETRSEAIANT F i tfflt 3 B HORIZONTAL SECTION US 8 TYPICAL JAMBAN040RAGE81gzz 9/ 1512017 LUCAS A TURNER, P.E. FL PE 0 56201 1239 JABARA AVE. NORTH PORT, FL 34288 PH. 941380. 1574 MET M3CJWlFlW. INSTALLATION DETAILS AN OY13/ 09 CWS•242 E SHEET 12 SOFS RECORD COPY FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Single Family Builder Name: Street: 417 W 12th St State, Zip: Sanford FL 32771 Permit Office: pCity, Permit Number. # 1 8 3 0 0 7Owner. OINWESUZUKISERG98Jurisdiction: Design Location: FL, Orlando County:: Seminole (Florida Climate Zone 2) 1. New construction or existing New (From Plans) 9. Wall Types (1168.0 sgft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=13.0 1168.00112 b. N/A R= fN 3. Number of units. If multiple family 1 c. N/A R= ft= 4. Number of Bedrooms 2 d. N/A R= ft' 5. Is this a worst case? No 10. Ceiling Types (1144.0 sqf .) Insulation Area a. Under Attic (Vented) R=30.0 1144.00 fN 6. Conditioned floor area above grade (W) 1144 b. N/A R= ft= Conditioned floor area below grade (M 0 c. N/A R= ft= 11. Ducts R ft' 7. Wlndows(196.0 sgft.) Description Area a. Sup: Attic, Ret: Attic, AH: Main 6 271.6 a. U-Factor. Sgl, U=0.55 196.04 ft= SHGC: SHGC=0.50 b. U-Factor. N/A ft= 12. Cooling systems kBUAY Efficiency SHGC: a. Central Unit 30.0 SEER:14.00 c. U-Factor. N/A ft' SHGC: 13. Heating systems kBtuRv Efficiency d. U-Factor. N/A fts a. Electric Heat Pump 30.0 HSPF:8.20 SHGC: Area Weighted Average Overhang Depth: 1.000 ft. Area Weighted Average SHGC: 0.500 14. Hot water systems a. Electric Cap: 40 gallons8. Floor Types (1144.0 sgft.) Insulation Area EF: 0.920 a. Raised Floor R=13.0 1144.00 ft' b. Conservation features b. N/A R= fN None c. N/A R= fP 15. Credits CF. Pstat Glass/Floor Area: 0.171 Total Proposed Modified Loads: 42.75 PASSTotalBaselineLoads: 45.61 1 hereby certify that the plans and specifications covered by Review of the plans and O THE S-r this calculation are in compli nc h the lorida Energy specifications covered by this indicates AV g 0% Code. calculation compliance N . OwiththeFloridaEnergyCode. n,,,#'• PREPARE Before construction is completed aV. DATE: this building will be Inspected for aovocompliancewithSection553.908 I hereby certify the this building, as designed, is in compliance Florida Statutes. 5 r, CODwiththeFloridaEnergyCode. W-1-1 OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: !G let -/ 8 Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 3.99 ACH50 (R402.4.1.2). Compliance with a proposed duct leakage On requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSURESNET/ICC 380, is not greater than 0.030 On for whole house. 6/18/2018 9:43 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 4 FORM R405-2017 PROJECT Title: Building Type: Owner Name: of Units: Builder Name: Permit Office: Jurisdiction: Family Type: New/Existing: Comment: Single Family User SUZUKMERG98 1 Single-family New (From Plans) Bedrooms: 2 Conditioned Area: 1144 Total Stories: 1 Worst Case: No Rotate Angle: 0 Cross Ventilation: Whole House Fan: Address Type: Street Address Lot # Block/Subdivision: PlatBook: Street: 417 W 121h St County: Seminole City, State, Zip: Sanford , FL, 32771 CLIMATE V Design Location Design Temp TMY Site 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, Orlando FL_ORLANDO INTL AR 41 91 70 75 526 44 Medium BLOCKS Number Name Area Volume 1 Blockl 1144 9152 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 1144 9152 Yes 3 2 1 Yes Yes Yes FLOORS Floor Type Space R-Value Area Tile Wood Carpet 1 Raised Floor Main 1144 fN 13 0.7 0 0.3 ROOF Type Roof Gable Roof Materials Area Area Color Solar Absor. SA Emitt Emitt Deck Tested Tested Insul. Pitch deg) 1 Hip Metal 1239 ftz 0 fl' Unfinishe 0.7 No 0.7 No 13 22.6 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 No attic Vented 300 1144 fl' N N CEILING Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) Main 30 Double Batt 1144 fV 0.11 Wood 6/18/2018 9:43 PM EnergyGaugeO USA - FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 4 FORM R405 2017 WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Beknv 1 2 3 4 N W S E Exterior Concrete Block - Int Insul Main Exterior Concrete Block - Int Insul Main Exterior Concrete Block - Int Insul Main Exterior Concrete Block - Int Insul Main 13 38 8 13 35 8 13 38 8 13 35 8 304.0 ft' 280.0 ft' 304.0 ft' 280.0 ft' 0 0.75 0 0.75 0 0.75 0 0.75 0 0 0 0 DOORS Omt Door Type Space Storms U-Value Width Ft In Height Ft In Area 1 W Insulated Main Metal 28 3 6 8 20 ft' WINDOWS Orientation shown is the entered Proposed orientation. Wait Omt ID Frame Panes NFRC U-Factor SHGC Imp Overhang Area Depth Separation Int Shade Screening 1 2 3 4 5 6 N 1 Vinyl Single (Clear) N 1 Vinyl Single (Clear) W 2 Vinyl Single (Clear) S 3 Vinyl Single (Clear) S 3 Vinyl Single (Clear) E 4 Vinyl Single (Clear) Yes Yes Yes Yes Yes Yes 0.55 0.5 N 0.55 0.5 N 0.55 0.5 N 0.55 0.5 N 0.55 0.5 N 0.55 0.5 N 47.3 ft' 1 ft 0 in 1 ft 0 in 12.5 ft2 1 ft 0 in 1 ft O In 63.0 ft= 1 ft 0 in 1 ft 0 In 18A ft' 1 ft 0 in 1 ft 0 in 20.6 ft' 1 ft 0 in 1 ft0 in 34. 3 ft' 1 ft 0 In 1 ft 0 In Drapes/ blinds Drapes/ blinds Drapes/ bUnds Drapes/ blinds Drapes/ blinds Drapes/ blinds None None None None None None INFILTRATION Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000203 608.6 33AI 62.84 .1481 3.99 HEATING SYSTEM System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ None HSPF:8.2 30 kBh #hr 1 sys#1 COOLING SYSTEM System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ None SEER: 14 30 kBtulhr 900 cfm 0.75 1 Sys" HOT WATER SYSTEM System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Main 0.92 40 gal 50 gal 120 deg None 6/ 18/2018 9:43 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 4 FORM R4052017 SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model Area Volume FEF None None ft= DUCTS Supply -- Return — Air CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic 6 271.6 ft Attic 67.9 fta Prop. Leak Free Main dm 34.3 cfm 0.03 0.50 1 1 TEMPERATURES Programable Thermostat: Y Ceiling Fens: Cooling Jan Heating Jan Feb Feb Mari MarW r [ AAApppr ( May [X Jun Jul May [ ] Jun Jul Aug Se4Sep Oct Oct (X] Nov Nov DecHDecVentiJanFebMarr ! Ma [) Jun Jul Au 11 Se Oct [XI Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 6/18/2018 9:43 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 4 FORM R405-2017 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 94 The lower the EnergyPerfonnance Index, the more efficient the home. 417 W 12th St, Sanford, FL, 32771 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (W) 7. Windows" Description a. U-Factor. Sgl, U=0.55 SHGC: SHGC=0.50 b. U-Factor. N/A SHGC: c. U-Factor. N/A SHGC: d. U-Factor. N/A SHGC: Area Weighted Average Overhang Depth: Area Weighted Average SHGC: 8. Floor Types a. Raised Floor b. N/A c. NIA New (From Plans) 9. Wall Types Insulation Area Single-family a. Concrete Block - Int Insul, Exterior R=13.0 1168.00 ft' b. N/A R= ft' 1 c. N/A R= ft' 2 d. N/A R= ft' 10. Ceiling Types Insulation Area No a. Under Attic (Vented) R=30.0 1144.00 ft' 1144 b. N/A R= ft' Area c. NIA R= ft' 196.04 fN 11. Ducts a. Sup: Attic, Ret: Attic, AH: Main R ft' 6 271.6 fN 12. Cooling systems kBhft Efficiency ft' a. Central Unit 30.0 SEER:14.00 ft' 13. Healing systems kBtuRrr Efficiency a. Electric Heat Pump 30.0 HSPF:8.20 1.000 ft. 0.500 Insulation Area 14. Hot water systems Cap: 40 gallons R=13.0 1144.00 ft' a• Electric EF: 0.92 R= ft' b. Conservation featuresR= ft' None 15. Credits CF. Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which Will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: Address of New Home: Date: City/FL Zip: 0oliE STgr 0,.e W t',4, •' , y, ` tea`, < f moo Wf Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 6/18/2018 9:43 PM EnergyGauge® USA - FlaRes2017 - Section R405.4.1 Compliant Software Page 1 of 1 Florida Building Code, Energy Conservation, 6th Edition (2017) Mandatory Requirements for Residential Performance, Prescriptive and ERI Methods ADDRESS: 417 W 12th St Permit Number: Sanford , FL , 32771 MANDATORY REQUIREMENTS See individual code sections for full details. SECTION R401 GENERAL R401.3 Energy Performance Level (EPL) display card (Martdatory)The building official shall require that an energy performance level (EPL) display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy. Florida law (Section 553.9085, Florida Statutes) requires the EPL display card to be Included as an addendum to each sales contract for both presokf and nonpresold residential buildings. The EPL display card contains information Indicating the energy performance level and efficiencies of components installed in a dwelling unit. The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans and specifications submitted to demonstrate code compliance for the building. A copy of the EPL display card can be found in Appendix RD. R402.4 Air leakage (Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of Sections R402.4.1 through R402A.5. Exception: Dwelling units of R-2 Occupancies and multiple attached single family dwellings shall be permitted to comply with Section C402.5. R402.4.1 Building thermal envelope. The building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2. The sealing methods between dissimilar materials shall allow for differential expansion and contraction. R402.4.1.1 InstalladomThe components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance with the manufacturer's instructions and the criteria listed In Table R402.4.1.1. as applicable to the method of construction. Where required bythe code official, an approved third party shall inspect all components and verify compliance. R402A.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate not exceeding seven air changes per hour in Climate Zones 1 and 2, and three air changes per hour in Climate Zones 3 through 8. Testing shall be conducted in accordance with ANSVRESNET/ICC 380 and reported at a pressure of 0.2 inch w.g. (50 pascals). Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(f), (g) or (1) or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. Exception: Testing is not required for additions, alterations, renovations, or repairs, of the building thermal envelope of existing buildings in which the new construction is less than 85 percent of the building thermal envelope. During testing: 1. Exterior windows and doors, fireplace and stove doors shall be closed, but not seated, beyond the Intended weatherstripping or other infiltration control measures. 2. Dampers including exhaust, intake, makeup air, backdraR and flue dampers shall be closed, but not sealed beyond intended infiltration control measures. 3. Interior doors, if Installed at the time of the test, shall be open. 4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5. Heating and cooling systems, 9 Installed at the time of the test, shall be turned off. 6. Supply and return registers, if installed at the time of the test, shall be fully open. R402.4.2 Fireplaces. New wood-buming fireplaces shall have tight -fitting flue dampers or doors, and outdoor combustion air. Where using tight -fitting doors on factory -built fireplaces listed and labeled in accordance with UL 127, the doors shall be tested and listed for the fireplace. Where using tight -fitting doors on masonry fireplaces, the doors shall be listed and labeled in accordance with UL 907. R402.4.5 Fenestration air leakageWindows, skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 dm per square toot (1.5 Us/m2), and swinging doors no more than 0.5 cum per square foot (2.6 Us/m2), when tested according to NFRC 400 or AAMA/ WDMA/CSA 101/I.S.2/A440 by an accredited, independent laboratory and listed and labeled by the manufacturer. Exception: Site -built windows, skylights and doors. 6/18/2018 9:43 PM EnergyGauge® USA - FlaRes2017 - FSC 6th Edition (2017) Compliant Page 1 of 5 MANDATORY REQUIREMENTS - (Continued) R402.4.4 Rooms containing fuel -burning appliances. In Climate Zones 3 through 8, where open combustion air ducts provide combustion air to open combuston fuel burning appliances, the appliances and combustion air opening shall be located outside the building thermal envelope or enclosed In a room, Isolated from inside the thermal envelope. Such rooms shall be sealed and insulated in accordance with the envelope requirements of Table R402.1.2, where the walls, floors and ceilings shall meet not less than the basement wall R-value requirement. The door Into the room shall be fully gasketed and any water lines and ducts in the room insulated in accordance with Section R403. The combustion air duct shall be insulated where it passes through conditioned space to a minimum of R-8. Exceptions: Direct vent appliances with both intake and exhaust pipes installed continuous to the outside. Fireplaces and stoves complying with Section R402.4.2 and Section R1006 of the Florida Building Code, Residential. R402A.6 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage between conditioned and unconditioned spaces. All recessed luminaires shall be IC -rated and labeled as having an air leakage rate not more than 2.0 cfm (0.944 Us) when tested in accordance with ASTM E283 at a 1.57 psf (75 Pa) pressure differential. All recessed luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering. SECTION R403 SYSTEMS R403.1 Controls. R403.1.1 Thermostat provision (Mandatory). At least one thermostat shall be provided for each separate heating and cooling system. R403.1.3 Heat pump supplementary heat (Mandatory). Heat pumps having supplementary electric -resistance heat shall have controls that, except during defrost, prevent supplemental heat operation when the heat pump compressor can meet the heating load. R403.3.2 Sealing (Mandatory) All ducts, air handlers, filter boxes and building cavities that forth the primary air containment passageways for air distribution systems shall be considered ducts or plenum chambers, shall be constructed and sealed in accordance with Section C403.2.9.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria below. Duct tightness shall be verified by testing in accordance with ANSI/RESNET/ICC 380 by either individuals as defined in Section 553.993(5) or (7), Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(f), (9) or (i). Florida Statutes, to be 'substantially leak free" in accordance with Section R403.3.3. R403.3.2.1 Sealed air handler. Air handlers shall have a manufacturer's designation for an air leakage of no more than 2 percent of the design airflow rate when tested In accordance with ASHRAE 193. R403.3.3 Duct testing (Mandatory). Ducts shall be pressure tested to determine air leakage by one of the following methods. Rough -in test: Total leakage shall be measured with a pressure differential of 0.1 Inch w.g. (25 Pa) across the system, including the manure handler enclosure if installed at the time of the test. All registers shall be taped or otherwise sealed during the test. Postconstructkm test: Total leakage shall be measured with a pressure differential of 0.1 inch w.g. (25 Pa) across the entire system, including the manufacturer's air handler enclosure. Registers shall be taped or otherwise sealed during the test. Exceptions: 1. A duct air leakage test shall not be required where the ducts and air handlers are located entirely within the building thermal envelope. 2. Duct testing Is not mandatory for buildings complying by Section 405 of this code. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. R403.3.6 Building cavities (Mandatory). Building framing cavities shall not be used as duds or plenums. R403A Mechanical system piping Insulation (Mandatory). Mechanical system piping capable of carrying fluids above 105°F (41•C) or below 55-F (13'C) shall be insulated to a minimum of R-3. R403.4.1 Protection of piping insulation. Piping insulation exposed to weather shall be protected from damage, including that caused by sunlight, moisture, equipment maintenance and wind, and shall provide shielding from solar radiation that can cause degradation of the material. Adhesive tape shall not be permitted. R403.5.1 Heated water circulation and temperature maintenance systems (Mandatory)Heated water circulation systems shall be in accordance with Section R403.5.1.1. Heat trace temperature maintenance systems shall be in accordance with Section R403.5.1.2. Automatic controls, temperature sensors and pumps shall be accessible. Manual controls shall be readily accessible. R403.6.1.1 Circulation systems. Heated water circulation systems shall be provided with a circulation pump. The system return pipe shall be a dedicated return pipe ora cold water supply pipe. Gravity and thermosiphon circulation systems shall be prohibited. Controls for circulating hot water system pumps shall start the pump based on the identification of a demand for hot water within the occupancy. The controls shall automatically turn off the pump when the water in the circulation bop is at the desired temperature and when there is no demand for hot water. R403.6.1.2 Heat trace systems. Electric heat trace systems shall comply with IEEE 515.1 or UL 515. Controls for such systems shall automatically adjust the energy input to the heat tracing to maintain the desired water temperature in the piping in accordance with the times when heated water is used in the occupancy. 6/18/2018 9:43 PM EnergyGauge® USA - FlaRes2017 - FBC 6th Edition (2017) Compliant Page 2 of 5 MANDATORY REQUIREMENTS - (Continued) R403.6.6 Heat traps (Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have heat traps Installed on both the Inlets and outlets. External heat traps shall consist of either a commercially available heat trap or a downward and upward bend of at least 3 % inches (89 mm) In the hot water distribution One and cold water line located as dose as possible to the storage tank. R403.6.6 Water heater efficiencies (Mandatory). R403.5.6.1.1 Automatic controls. Service water -heating systems shag be equipped with automatic temperature controls capable of adjustment from the lowest to the highest acceptable temperature settings for the Intended use. The minimum temperature setting range shall be from 100°F to 140OF (389C to 6(rC). R403.6.6.1.2 Shut down. A separate switch or a dearly marked circuit breaker shall be provided to permit the power supplied to electric service systems to be turned off. A separate valve shall be provided to permit the energy supplied to the main bumer(s) of combustion types of service water -heating systems to be turned off. R403.5.6.2 Water -heating equipment. Water -heating equipment installed In residential units shall meet the minimum efficiencies of Table C404.2 in Chapter 4 of the Florida Building Code, Energy Conservation, Commercial Provisions, for the type of equipment Installed. Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water -heating category. Solar water heaters shall meet the criteria of Section R403.5.6.2.1. R403.6.6.2.1 Solar water -heating systems. Solar systems for domestic hot water production are rated by the annual solar energy factor of the system. The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of Certified Solar Systems. Solar collectors shall be tested in accordance with ISO Standard 9806. Test Methods for Solar Collectors, and SRCC Standard TMA, Solar Domestic Hot Water System and Component Test Protocol. Collectors in installed solar water4mating systems should meet the following criteria: 1. Be installed with a till angle between 10 degrees and 40 degrees of the horizontal; and 2. Be installed at an orientation within 45 degrees of true south. R403.6 Mechanical ventilation (Mandatory). The building shall be provided with ventilation that meets the requirements of the Florida Building Code, Residential, or Florida Building Code, Mechanical, as applicable, or with other approved means of ventilation including: Natural, Infiltration or Mechanical means. Outdoor air Intakes and exhausts shall have automatic or gravity dampers that dose when the ventilation system is not operating. R403.6.1 Whole -house mechanical ventilation system fan efficacy. When installed to function as a whole -house mechanical ventilation system, fans shall meet the efficacy requirements of Table R403.6.1. Exception: Where whole -house mechanical ventilation fens are integral to tested and listed HVAC equipment, they shag be powered by an electronically commutated motor. R403.62 Ventilation air. When Installed to function as a whoia-house mechanical ventilation system, fans shall meet the efficacy requirements of Table R403.6.1. 1. The design air change per hour minimums for residential buildings in ASHRAE 62.2, Ventilation for Acceptable Indoor Air Quality, shall be the maximum rates allowed for residential applications. No ventilation or air-conditioning system make-up air shall be provided to conditioned space from attics, crawlspaces, attached enclosed garages or outdoor spaces adjacent to swimming pools or spas. If ventilation air Is drawn from enclosed space(s), then the walls of the space(s) from which air is drawn shall be insulated to a minimum of R-11 and the ceding shag be Insulated to a minimum of R-19, space permitting, or R-10 otherwise. R403.7 Heating and cooling equipment (Mandatory). R403.7.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies, based on building loads for the directional orientation of the building. The manufacturer and model number of the outdoor and indoor units (if split system) shall be submitted along with the sensible and total cooling capacities at the design conditions described in Section R302.1. This Code does not allow designer safety factors, provisions for future expansion or other factors that effect equipment string. System sizing calculations shall not include loads created by local intermittent mechanical ventilation such as standard kitchen and bathroom exhaust systems. New or replacement heating and tooting equipment shell have an efficiency rating equal to or greater than the minimum required by federal law for the geographic location where the equipment is Installed. TABLE R403.6.1 WHOLE -HOUSE MECHANICAL VENTILATION SYSTEM FAN EFFICACY FAN LOCATION AIRFLOW RATE MINIMUM CFM) MINIMUM EFFICACY a CFM/WATT) AIRFLOW RATE MAXIMUIV CFM) Range hoods Any 2.8 ctm/watt Any Inaine fan Any 2.8 cfm/watt Any Bathroom, utility room 10 1.4 cfm/watt 90 Bathroom, utility room 90 2.8 cfm/watt Any For SI: 1 cfm = 28.3 Umin. a. When tested in accordance with HVI Standard 916 6/18/2018 9:43 PM EnergyGauge® USA - FlaRes2017 - FBC 6th Edition (2017) Compliant Page 3 of 5 I MANDATORY REQUIREMENTS - (Continued) R403.7.1.1 Cooiing equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less than the calculated total load but not more than 1.15 times greater than the total bad calculated according to the procedure selected In Section 403.7, or the closest available size provided by the manufacturer's product lines. The corresponding latent capacity of the equipment shall not be less than the calculated latent load. The published value for AHRI total capacity is a nominal, rating -test value and shell not be used for equipment sizing. Manufacturer's expanded performance date shall be used to select cooling -only equipment. This selection shall be based on the outdoor design dry-bulb temperature for the load calculation (or entering water temperature for water -source equipment), the blower CFM provided by the expanded performance data, the design value for entering wet -bulb temperature and the design value for entering dry-bulb temperature. Design values for entering wet -bulb and dry-bulb temperatures shall be for the indoor dry bulb and relative humidity used for the bad calcination and shall be adjusted for return side gains If the return duct(s) Is Installed In an unconditioned space. Exceptions: 1. Attached single- and muWple-family residential equipment sizing may be selected so that its cooling capacity is less than the i calculated total sensible load but not less than 80 percent of that load. 2. When signed and sealed by a Florida -registered engineer, in attached single- and multiple -family units, the capacity of equipment may be sized in accordance with good design practice. R403.7.1.2 Heating equipment capacity. R403.7.111 Heat pumps. Heat pump sizing shall be based on the cooling requirements as calculated according to Section R403.7 1.1, and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling bad even if the design heating load is 1.15 times greater than the design cooling load. R403.7.122 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design requirements calculated according to the procedure selected In Section R403.7.1. R403.7.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners shall not be less then the design load calculated in accordance with Section 11403.7.1. R403.7.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an intermittent basis, such as anticipated additional loads caused by major entertainment events, shall have equipment sized or controlled to prevent continuous space cooling or heating within that space by one or more of the following options: A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas. A variable capacity system sized for optimum performance during base load periods is utilized. R403.8 Systems serving multiple dwelling units (Mandatory). Systems serving multiple dwelling units shall comply with Sections C403 and C404 of the IECC--Commercial Provisions in lieu of Section R403. R403.8 Snow melt and ice system controls (Mandatory) Snow- and ice -melting systems, supplied through energy service to the building, shall Include automatic controls capable of shutting off the system when the pavement temperature is above 5VF (10'C), and no precipitation Is failing and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40°F (4.8°C). R403.10 Pools and permanent spa energy consumption (Mandatory). The energy consumption of pools and permanent spas shall be in accordance with Sections R403.10.1 through R403.10.5. R403.10.1 Heaters. The electric power to heaters shall be controlled by a readily accessible on -off switch that is an integral part of the heater mounted on the exterior of the heater, or external to and within 3 feet (914 mm) of the heater. Operation of such switch shall not change the setting of the heater thermostat. Such switches shall be in addition to a circuit breaker for the power to the heater. Gas -fired heaters shall not be equipped with continuously burning ignition pilots. R403.102 Time switches. Time switches or other control methods that can automatically turn off and on according to a preset schedule shall be Installed for heaters and pump motors. Heaters and pump motors that have built-in time switches shall be In compliance with this section. Exceptions: 1. Where public health standards require 24-hour pump operation. 2. Pumps that operate solar- and waste-heat-reoovery pool heating systems. 3. Where pumps are powered exclusively from on -site renewable generation. R403.10.3 Covers. Outdoor heated swimming pools and outdoor permanent spas shall be equipped with a vapor -retardant cover on or at the water surface or a liquid cover or other means proven to reduce heat loss. Exception: Where more than 70 percent of the energy for heating, computed over an operation season, is from site -recovered energy, such as from a heat pump or solar energy source, covers or other vapor -retardant means shall not be required. R403.10.4 Gas- and oilfired pool and spa heaters. All gas- and oil -fired pool and spa heaters shall have a minimum thermal efficiency of 82 percent for heaters manufactured on or after April 16. 2013, when tested in accordance with ANSI Z 21.56. Pool heaters fired by natural or LP gas shall not have continuously burning pilot lights. 6/18/2018 9:43 PM EnergyGauge® USA - FlaRes2017 - FBC 6th Edition (2017) Compliant Page 4 of 5 R403.10.5 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance with AHRI 1160, Table 2, Standard Rating Conditions -Low Air Temperature. A test report from an Independent laboratory is required to verify procedure compliance. Geothermal swimming pool heat pumps are not required to meet this standard. R403.11 Portable spas (Mandatofte energy consumption of electrlo-powered portable spas shall be controlled by the requirements of APSP-14. SECTION R404 ELECTRICAL POWER AND LIGHTING SYSTEMS R404.1 Lighting equipment (Mandatory). Not less than 75 percent of the lamps in permanently installed lighting fixtures shall be high -efficacy lamps or not less than 75 percent of the permanently installed lighting fixtures shall contain only high -efficacy lamps. Exception: Low -voltage lighting. R404.1.1 Lighting equipment (Mandatory)Fuel gas lighting systems shall not have continuously burning pilot fights. 6/182018 9:43 PM EnergyGauge® USA - FlaRes2017 - FBC 6th Edition (2017) Compliant Page 5 of 5 2017 -AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: Single Family Builder Name: Street: 417 W 12th St Permit Office: City, State, Zip: Sanford, FL , 32771 Permit Number. Owner. SUZUKISERG98 Jurisdiction: Design Location: FL, Orlando COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable Insulation shall requirements The exterior thermal envelope contains a continuous all barrier, not be used as a sealing material. Breaks or joints In the air barrier shall be sealed. Celling/attic The air barrier in any dropped ceiiing/sofrd shag be aligned with the The insulation in any dropped ceiling/soffit insulation and any gaps in the air barrier shag be sealed. shag be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Wags The junction of the foundation and sill plate shall be sealed. Cavities within comers and headers of frame walls shall The junction of the top plate and the top of exterior walls shall be sealed. be insulated by completely filling the cavity with a Knee walls shall be sealed. material having a thermal resistance of R-3 per Inch minimum. Exterior thermal envelope insulation for framed walls shall be Installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/door jambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of insulation. Floor framing cavity insulation shall be Installed to including maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity Insulation and cantilevered shag be permitted to be in contact with the top side of floors) sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with a Where provided Instead of floor insulation, insulation Class 1 vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls. Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shag be cut to fit, or narrow shall be filed by Insulation that on installationNarrowcavitiesreadilyconformstotheavailablecavityspaces. readily Garage separation Air sealing shag be provided between the garage and conditioned space,. Recessed lighting Recessed light fbdures installed In the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be air light and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing In exterior walls, or insulation that on installation readily conforms to available space shall Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall be on exterior wall tubs shall separate them from the showers and tubs. insulated. Electrical/phone box on The air barrier shall be Installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shag be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed In a manner that Is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire a. in aaanron, Inspecson of log wails snarl ve In awomanae whit um piuvowuru v# wv-rvv. 6/18/2018 9:43 PM EnergyGauge® USA - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 FORM R405-2017 Envelope Leakage Test Report Performance FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Envelope Leakage Test Report Performance Method Project Name: Single Family Builder Name: Street: 417 W 12th St Permit Office: City, State, Zip: Sanford, FL, 32771 Permit Number: Design Location: FL, Orlando Jurisdiction: Cond. Floor Area:: 1144 sq.ff. Cond. Volume: 9152 cu ft. Envelope Leakage Test Results Regression Data: C: n: Single or Multi Point Test Data R: HOUSE PRESSURE FLOW: 1 Pa cfm 2 Pa cfm 3 Pa cfm 4 Pa cfm 5 Pa cfm 6 Pa cfm Leakage Characteristics Required ACH(50) from Q FORM R405-2017 : 3- -1 Tested ACH(50)' : 0, l Tested leakage must be less than or equal to the required ACH(50) shown on Form R405-2017 for this building. If the tested ACH(50) is less than 3 the building must have a mechanical ventilation system. R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour in Climate Zones 1 and 2 ... Testing shall be conducted with a blower door at a pressure of 0.2 Inches w.g. (50 Pascals). Testing shall be conducted by either individuals as defined In Section 553.993(5) or (7), Florida Statutes or individuals licensed as set forth in Section 489.105(3)(f), (9), or (1) or an approved third party. A written report ofthe results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of all penetrations of fhe building thermal envelope. During testing: 1. Exterior windows and doors, fireplace and stove doors shall be dosed, but not sealed, beyond the intended weatherstripping or other Infiltration control measures; 2. Dampers Including exhaust, intake, makeup air, backdraft and flue dampers shag be dosed, but not sealed beyond intended infiltratlon control measures; 3. Interior doors, If installed at the time of the test, shag be open; 4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be dosed and sealed; 5. Heating and cooling systems, if Installed at the time of the test, shall be tumed off; and 6. Supply and return registers, if installed at the time of the test, shall be fully open. I hereby certify that the above envelope leakage performance results demonstrate compliance with Florida Energy Code requirements in accordance with Section R402.4.1.2. SIGNATURE: PRINTED NAIL V 4da H VasQute- DATE: T Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statutes or individuals licensed as set forth in Section 489.105(3)(f), (g), or (i) or an approved third party. A written report of the results of the test shall be signed by the third party conducting the test and provided to the code official. BUILDING OFFICIAL: DATE: D,q Sr 1" V ' 0 Wf 6/18/2018 9:43 PM EnergyGauge® USA - FlaRes2017 - Section R405.4.1 Compliant Software Page 1 of 1 FORM R4Q5-2017 Duct Leakage Test Report Performance Method FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Form R405 Duct Leakage Test Report Performance Method Project Name: Singe Family Builder Name: Street: 417 W 12th St Permit Office: City, State, Zip: Sanford , FL , 32771 Permit Number. Design Location: FL, Orlando Jurisdiction: Duct Test Time: Post Construction Required Duct Leakage from 6,7038-) (Qn,out) FORMR405-2017 Duct Leakaae Test Results CFM25 Duct Leakage Test Values Line System Outside Duct Leakage 1 System 1 CFM25(Out) 2 System 2 CFM25(Out) 3 System 3 CFM25(Out) 4 System 4 CFM25(Out) 5 System 5 CFM25(Out) Tested Sum lines 1-5 Total Divide by 1144 House Duct Total Conditioned Floor Area) System J,03D (Qn,out)• Leakage Tested Qn (Out) must be less than or equal to the required Qn (Out). I certify the tested duct leakage to outside, Qn, is less than or equal to the proposed duct leakage Qn specifie on F M R405-2017. SIGNATURE: , I PRINTED E:y0.S4ue DATE: 6/18/2018 Duct tightness shall be verified by testing to ANSI/RESNET/ICC 380 by either individuals as defined in Section 553.993(5) or (7). Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(f), g), or (i), Florida Statutes. BUILDING OFFICIAL: DATE: CHE ST4 N. v 6/18/2018 9:43 PM EnergyGauge® USA - FlaRes2017 - Section R405A.1 Compliant Sor Page 1 of 1 CITY OF PERMIT APPLICATION A = SAJ FORD BUILDING DIVISION Application No: 3 dd 7 Documented Construction Value: Job Address: Historic District: Yes NoW I Parcel ID: 2S_ 1 o30 - 136 - (_a Residential 0 Commercial Type of Work: New Addition Alteration 91 Repair Demo Change of Use Move Description of Work: tLe'll 'cri Plan Review Contact Person: A(-Yj/l \Title: Caucd jr q 2S2 Cte W 9c - Phone: (, Fax: U —Email: S"I- M t S _Y•6? 61$ 61& Property Owner Information Name CA C 45tG'd ! Phone: Street: - 7 t2 S oltpp? -()A ahoze Resident of property? 0 11. P ' City, State Zip: L `2 22 m e E r a £ -4-rI iI Contractor Information Name i Y11Lp/` - a Z, Phone: Street: 1, > O bi S *3 1F, U Fax: City, State Zip: Vl RAN4 1 R 3 t(: ( - - State License No.: Architect/ Engineer Information Name: eAA S `Q Phone: Street: Fax: City, St, Zip: E-mail: Bonding Company: (c,-, Mortgage Lender: Address: Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work orinstallation has commenced prior to the issuance of apermit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: Vh Edition (2017) Florida Building Code NOTICE: In addition to the requirements of this permit, there maybe additional restrictions applicable to this property that maybe found in thepublic records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal. The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value, credit will be applied to your permit fees when the permit is issued. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Signature of Owner/Agent Print Owner/Agent's Name Date Signature of Notary -State of Florida Date Sfgature of 96ntractor/Agent Bate 3vy nn Print Contractor/Agent's Name Signature of Notary y;.e,•; I EBBIE8 t ION MY COMMISSION 1 FF 17W8 A;.a EXPIRES: February 25, 2019 Donded Thro wt.,/ Pu06c Uede ters Owner/Agent is Personally Known to Me or Contractor/Agts-"P s n own to Me or Produced ID Type ofID Produced ID Type ofID — 5 / de• 1 b BELOW IS FOR -OFFICE -USE ONLY Permits Required: Building Electrical Mechanical Plumbing Gas Roof Construction Type: Occupancy Use: Total Sq Ft of Bldg: Min. Occupancy Load: Flood Zone: of Stories: New Construction: Electric - # of Amps Plumbing - # of Fixtures Fire Sprinkler Permit: Yes No # of Heads APPROVALS: ZONING: ENGINEERING: COMMENTS: UTILITIES: FIRE: Fire Alarm Permit: Yes []No WASTE WATER: BUILDING:,, CITY OF PERMIT APPLICATION p r SA FORD BUILDING DIVISION Application Igo: Documented Construction Value: $ Job Address: Parcel ID• Type of Work: New Description ofWork: _ Plan Review Contact Person: Phone: Name Street: City, State Zip: Name Street: City, State Zip: Name: Street: City, St, Zip: Bonding Company: Address: Alteration Repair Fax: Historic District: Yes No Residential Commercial Change of Use Move Title: Email: iformation Phone: Resident of property?: Information Phone: Fax: State License No.: Phone: Fax: E-mail: Address: Lender: WARNING TO OWNER. YOUR FAILURE TO RECORD A NOTICE OF COMME EMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COM CEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTE TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE F COMMENCEMENT Application is hereby made to obtain a permit to do the work and installations as indicated. I certify t no work or installation has commenced prior to the issuance ofa permit and that all work will be performed to meet standards of all laws regulating onstruction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, oilers, heaters, tanks, and air conditioners, etc. POWER OF ATTORNEY Date: a4k I hereby name and appoint 2 of METRO ELECTRIC SERVICE INC to be my lawful attorney -in -fact to act for me, and apply to the Building Department for a for work to be performed at a location described as: ELECTRICAL permit Parcel ID #: Section Township Range & Subdivisions rBlock Lo at 15 Digit Parcel Number) Subdivision Name: Owner of Property: r C r, ( C4, c4fta ko Project Address: 7f 25'2'- CiF4&,Caz"/Zip COde:-72- and to sign my name and do all things necessary to this appointment. OMARJLiERNANDEA / / EC13005326 or—P44} f (Contractor's License Number) The foregoing instrument was acknowledged before me this day of 61 of 201, by Vi w leYnarA t who is personally known to me or who produced driar-sIt&y, as identification and who did not take an oath. L 14iSS-e Ase Notary Pu is (Print name) No blic (Signature) Ivelisse Asencio Seal NOTARY PUBLIC S STATE OF FLORIDA Commie GG237607 H tee Expires 8/14/2021 tips) t CITY OF SkNF0RD PERMIT APPLICATION BUILDING DIVISION / p, 2f0 7ApplicationNo: 00 Documented Construction Value: $ .2T-(J.. yc B 6 Job Address: ST. , r& FL W4P Historic District: Yes [I Nojo Parcel ID: Type of Work: New Addition Alteration [I Repair Description of Work: &O—Ln Coax oe!Ej Z (g llS S,PT Residential ?2 Commercial Demo Change of Use Move Q- 1-A .P (15-rio P Sfi)(7 A/C G Plan Review Contact Person: 3 ll0:! C rf S Title: Phone:QCX- Fax: CA Email: G twk Property Owner Information r/tlY 2 Name (('l. (C('A Phone: G Street: Lt(--sA 51 Resident ofproperty?: 0 City, State Zip: 241a A 0' CC,,0-0 " 4r ractor Information Name Q rir-e Phone: Street: City, State Zip: Fax: State License No.: CAC Architect/ Engineer Information Name: 1u ('-elm Phone: - Z.-L 2 (Cft Street: City, St, Zip: Bonding Company: Address: Fax: E- mail: Mortgage Lender: n CG1 Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. r FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: Vh Edition (2017) Florida Building Code NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time ofsubmittal. The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value, credit will be applied to your permit fees when the permit is issued. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Signature of Owner/Agent Print Owner/Agent's Name Date Signature of Contractor/Agent Date Print Contractor/Agent's Name Signature of Notary -State of Florida Date Signature of Notary -State of Florida Date Owner/Agent is Personally Known to Me or Contractor/Agent is Personally Known to Me or Produced ID Type of ID Produced ID Type of ID BELOW IS FOR OFFICE USE ONLY Permits Required:' Building Electrical Mechanical Plumbing Gas Roof Construction Type: Occupancy Use: Total Sq Ft of Bldg: Min. Occupancy Load: Flood Zone: of Stories: New Construction: Electric - # of Amps Plumbing - # of Fixtures Fire Sprinkler Permit: Yes No # of Heads APPROVALS: ZONING: ENGINEERING: COMMENTS: UTILITIES: FIRE: Fire Alarm Permit: Yes No WASTE WATER: BUILDING: 1PYRTED AUTHORIZATION LETTER authorize Nmrc or 91V68 Wnwrb: ba Husiow orCam Kole wadSPy /ya a to sign for me in order to obtain permit(s) Nome ofpoaoorearvh y" horvotbn under my business or contractor's license # /9 . ausiommComnCM 1k__ M This authorization letter is limited and valid only for the job located at: j' 7 I understand that,this Limited Authorization Letter must be -revoked in writing. Signature Print Name State of Florida County ofOsceola The foregoing instrument was acknowledged before me this y day of S U% by .Sos cpk L Tv vtS , who is personally known to me or who has produced as identification: Shaylcen Miranda • NOTARYPUBLIC a f STATE OF, FLORIDA Co"O GGi54246 Notary Pu isExpAres10/232021 011wuuWamWWAwh=kKWeLater- Lmtflcd.doc 40 Blue Marlin Engineering LLC 102 Drennen Rd., Suite B10, Orlando, FI 32806 * Ph: 407-217-4464*oplaza@bluemarlineneineering.com September 10, 2018 City of Sanford Building Permit 300 N. Park Ave. Sanford, FI 32771 rl Re: Letter of Approval for Building Permit 18-3007 for: 417121A St., Sanford, FI 32771. I, Osciel F. Plaza, licensed as Professional Engineer in the state of Florida, PE No. 73262 hereby certify that carpentry work and installation completed in bearing exterior wood frame and ceiling joist at 417 121h St., Sanford, FI 32771 with Building Permit 18-3007 by company 3VD Constructions LLC — Juan A. Vasquez Mata Certified General Contractor with License number CGC1520470 was done in accordance with current ``40a 8niJ g Code — Existing & Residential 2017 Volume and product specifications. 14AV4014i, I certifyArin are true and accurate to the best of my belief. 2 • SinceQ14 0 j1`d' t' oN is 0 - Osciel plaza'•.•• 3SN "PING••.•'A` OfSTATE OF FLORIDA t COUNTY OF OEPAR THE FOREGOING INSTRU E T WAS ACKNOWLEDGED BEFORE ME ON THIS DAYS OF 20 BY Mij- P11 WHO IS PERSONALLY KNOWN TO ME OR WHO PRODUCED FL AS IDENTIFICATION AND WHO DID NOT TAKE AN OATH. NOTARY PUBLIC ( PRINT NAME) MdpA(. eeseP NOTARY PUBLIC ( SIGNATURE) ry Public state of Florida Maria Keesee My COmmissloo FF 177t80 a Exphes 11n8r2018 SUZUKISERG98 417 W 12th ST. SANFORD FL 32771 PARCEL ID #25-19-30-5AG-1407-0060 INTERIOR ALTERATION Single Family Residence) 1 ^ 1 2th ST A Pr1AL, 'RMAD'AA1' I t_ _ 2' CLEM & L03, O1 PAtTVrnT 11 I I 6 D9•t7Vo• [ 117 orj') j I V 89'25'44" E 117'o) 1 -- oz,;; FOUND 1/2- ftn CAP. Wn- LECI; 1 1 0T G BLOCK 14 TIER / 9V 3tT 1/2' Cseet rat Ir3 no mc n fI1, s7D:o w PLA- 0 t '----------------- 3 Ir( P) t7 In METAL o O .^. tg- - 73'-t1' j 1 z 1 0 p s N n7'-2 I_ O T 7 i s 14 Tit f• N 89'25'44" E 117'l`Pi PROJECT INTERIOR ALTERATION SETBACKS - SITE PLAN SCALE 1/64• = 1' 00- I SCOPE OF WORK INTERIOR ALTERATION. ELECTRICAL AND MECHANICAL WORK. DRYWALL, BASEBOARD, FLOOR LAMINATE, INTERIOR DOOR, KITCHEN CABINETS, INTERIOR AND EXTERIOR PAINT. INDEX SHEET DESCRIPTION GI SITE PLAN. SETBACKS. NOTES. Al EXISTING FLOOR PLAN/DEMO. A2 PROPOSAL FLOOR PLAN. E1 ELECTRICAL PLAN. M1 MECHANICAL PLAN. D1 DETAILS. D2 DETAILS. SCHEDULE AREA(SF) SPACES V N V GR SINGLE FAMILY 1 1144 214 358 SINGLE FAMILY 2 486 STEEL/ PRE ENG. 3000 000 TOTAL LIVING AREA 1630 TOTAL GROSS AREA 4844 BUILDING LF FRONT 11.5 REAR 40.5' RIGHT SIDE 5.4' LEFT SIDE 74.3' See survey attached LX1511NU IMF'LKVIOUS AKLA SINGLE FAMILY 1 1358 SF SINGLE FAMILY 2 486 SF STEEL/ PRE ENG. INSULATED 3000 SF DRIVEWAY - SIDEWALK -ACCESS 400 SF LOT AREA 11700 SF IMPERVIOUS AREA 44 X 5 I KUU I UKAL UL51UN UM I LKIA EXPOSURE CATEGORY B BASIC WIND SPEED 140 INTERNAL PRESSURE COEFFICIENTS : BUILDING, ENCLOLSED +/- 0.18 NAND IMPORTANCE FACTOR 1 ROOF DESIGN NAND PRESSURE 30 PSF FBC, SECTION 1604.6 WINDOW DESIGN WIND PRESSURE: A. POSITIVE PRESSURE OF 22 P.S.F. B. NEGATIVE PRESSURE OF 30 P.S.F. DOOR DESIGN WIND PRESSURE: SLIDING GLASS DOORS : ALL SIZES A. POSITIVE PRESSURE OF 21 P.S.F. B. NEGATIVE PRESSURE OF 28 P.S.F. ENTRY DOOR: ALL CONFIGURATIONS A. POSITIVE PRESSURE OF 20 P.S.F. B. NEGATIVE PRESSURE OF 25 P.S.F. MINIMUM DISTRIBUTED LIVE LOADS BALCONIES AND DECKS (EXTERIOR) 40 Psf GUARDRAILS AND HANDRAILS 200 Psf GUADRAILS IN -FILL COMPONENTS 50 Psf PASSENGER VEHICLE GARAGES 50 Psf ROOMS OTHER THAN SLEEPING ROOOM : 40 Psf SLEEPING ROOMS 30 Psf STAIRS 40 Psf NOTES THIS STRUCTURE HAS BEEN DESIGNED TO MEET OR EXCEED THE 140 MPH WIND LOAD REQUIREMENTS OF SECTION III OF THE FLORIDA BUILDING CODE 2017 EDITION RESIDENTIAL THIS STRUCTURE HAS BEEN DESIGNED TO MEET OR EXCEED THE MECHANICAL, ELECTRICAL dt PLUMBING REQUIREMENTS OF ALL APPLICABLE STATE AND LOCAL CODES AND ORDINANCE. ELECTRICAL PLAN : BASED IN NEC 2014 MOBILE/ MANUFACTURED HOME SET-UP, REPAIR AND REMODELING SHALL COMPLY WITH THE MOBILE MANUFACTURED HOME INSTALLATION STANDARD DISCREPANCIES IN DRAWINGS 1— THE BUILDING CONTRACTOR/OWNER SHALL CHECK ARCHITECTURAL PLUMBING, MECHANICAL ELECTRICAL, STRUCTURAL DRAMANGS FOR OPENINGS, WINDOWS, SIEVES, ANCHORS, HANGERS, SLAB DEPRESSIONS, DIMENSIONS, PITCH AND OTHER RELATED ITEMS AND SHALL ASSUME RESPONSBIUTY FOR THEIR PROPER LOCATION, PLACEMENT AND CONTINUITY AND BEARING POINTS ON ROOF AND FLOOR TRUSS/RAFTER PLANS TO BE REFLECTED ON FOUNDATION PLANS. THE PROFESSIONAL OF RECORD SHALL BE NOTIFIED IN WRITING OF ANY VARIATION OR DEVIATION IN THE DIMESONS, CONDITIONS, AND SPECIFICATIONS ON THESE PLANS 2— GENERAL CONTRACTOR, SUBCONTRACTOR, MECHANICAL ELECTRICAL AND PLUMBING CONTRACTOR TO INSPECT THE EXISTING CONDITION PRIOR TO COMMENCING THE PROPOSE CONSTRUCTION. 3— ALL MATERIALS AND FINISHES TO MATCH EXISTING BUILDING. 4— ADHERE TO ALLSTATE. COUNTY AND LOCAL CODES 0 F aIi EVISIONS00 n Z me Cr) o w 41 z,A J wed a U) W Y3I- na Z Na Cn DATE 06/ 18/2018 NUMBER 2018- 0033 SHEET G1 Revision. SEP 10 2Q1$ City of Sanford Response to Comments Building & Fire Prevention Division 4' Ph: 407.688.5150 Fax: 407.688.5152 Email: building@sanfordfl.gov Permit # ` 300 Submittal Date (-) q liol 2 0 I S Project Address: Y I --• I Zfh a rQQf , d 4 -7 1 Contact: Manuel VMi v¢ q- Ph: ( 4©--Q Fax: Email: QGtvnC nVe w10i1 ( C O'l . Trades encompassed in revision: Building Plumbing Electrical Mechanical Life Safety Waste Water General description of revision: L 2:ke, CJ Wrdya I -For 1 6ji l c4 i n ner M i f ROUTING INFORMATION Department Approvals Utilities Waste Water Planning Engineering Fire Prevention 0 Building