2207 Community Way - BR17-003084 - DOOR10/14/2017 12:56PM 4076340400 LISACOOK DECKERDOORS PAGE 30
CITYCITY OF SANFORD
BUILDING & FIRE PREVENTION
PERMIT APPLICATION
Application No: / 9' 36
Documented Construction Value: $ b 1$D .14
Job Address:
t V VU Historic District: Yes No
Parcel ID: p
II--
Residential K Commercial]
Type of Work: New ,Addition Alteration RepairEl Demo Change of UseEl Move Description of
Work - Plan Review
Contact Person: Title: P/ J10111?-1Phone: qD7—
Z,q11 Og3Jl Fax: D _ !o - 73A& Email: Property Owner
Information Name ll
Street: 0/
City,
State
Zip: pt Name
Daniel T. Decker Phone: En/,
Resident of
property? 2. i
Contractor Information
Phone: 407-
696-0830 Street: 724
Brooks Court Fax: 407-
696-7356 City, State
Zip: State License No.: winter Springs,
FL 32708 CBC1250499 Architect/Engineer
Information Name: Street:
City,
St,
Zip: Bonding Company:
Address: Phone:
Fax:
E-
mail:
Mortgage Lender:
Address: WARNING
TO
OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAX RESULT IN YOUR PAYING TWICEFORIMPROVEMENTSTOYOURPROPERTY. A NOTICE OF COMMENCEMENT MUST RE RECORDED AND
POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT
WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Applicationis
hereby trade to obtain a permit to do the work and installations as indicated. i certify that no work or installation has commenecd prior
to the issuance of a permit and that all work will be performed to meet standards of all lawsregulating construction in thisjurisdiction, I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools,6 furnaces, boilers, heaters, tanks, and air conditioners, etc. 6 FBC
105.3 Shall be inscribed with the date of application andthe code in effect as of that date: 51h Edition (2014) Florida Building Code Revised: June
30, 2015 Permit Application
10/14/2017 12:56PM 4076340400 LISACOOK DECKERDOORS PAGE 31
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be
found in the public records ofthis county, and there may be additional permits required from other governmental entities such as water
manage>nent districts, state agencies, or federal agencies.
Acceptance of permit is verification that I will notify the owner of the property of the requirements ofFlorida Lien Law, FS 7I3.
The City of Sanford requires payment ofa plan review fee at the time of permit submittal. A copy of the executed contract is required
in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal.
The actual construction value will be figured based on the current [CC Valuation Table in effect at the time the permit is issued, in
accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value,
credit will be applied to your permit fees when the permit is issued.
OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will
be done in compliance with all applicable laws regulating construction and zoning.
Signature of Owner/Agent Date Signature, ofContmctor/Agent Pate
Daniel T. Decker
Print Owner/Agent's Name Print Contractor/Agent'sName
Signature of Notary -State of Florida Date
Owner/Agent is Personally Known to Me or
Produced ID Type of ID
Q
gnature ofNatary-State ofFlorida Date
DEBBIE BLANTON ---
MY COM>.11MON :"C 17E646
EXPIRES: February 25, 20-19
ofFt ' Bonded Thru Notaiy PublicUndemni!ers
Contractor/Agent is Personally Known to Me or
Produced ID Type of ID
BELOW IS FOR OFFICE USE ONLY
Permits Required: Building Electrical Mechanical Plumbing Gas Roof
Construction Type: Occupancy Use: Flood Zone:
Total Sq Ft of Bldg: Min. Occupancy Load: # of Stories:
New Construction: Electric - # of Amps Plumbing - # of Fixtures
Fire Sprinkler Permit: Yes No # of Heads Fire Alarm Permit: Yes No
APPROVALS: ZONING:
COMMENTS:
UTILITIES:
ENGINEERING: FIRE:
WASTE WATER:
BUILDING:
Revised: June 30, 2015 Permit Application
10/14/2017 12:56PM 4076340400 LISACOOK DECKERDDORS PAGE 34
Parcel Information
Parcel 36-19-30-534-1200-0050 1
Owner YANNI MOLLY
M
Property Address 2207 COMMUNITY WAY SANFORD. FL 32771
Mailing 2207 COMMUNITY WAY SANEORD, FL 32771 I
Subdivislon Name tiQj LA D PARK
Tax Dlstrlct 51.5ANFORD
OOR Use Code 01-SINGLE FAMILY j
Exemptions 00-H0MI_STEAD(2005)
1h
W
Sem nale County GIS
l Legal Description
LOTS 5 + 6 BLK 12
HIGHLAND PARK
PB 4 PG 26
Taxes
Find Gomfirabio 5aIE zs t
aoperty Record QrAiS
Parcel: 36-19-30-534-1200-0050
Owner; YAW MOLLY
Property Address: 2207 COMMUNITY WAY SAN FORD, FL 32771
j Value Summary
2017 Working 12016 Certified
i
Values I Values
Valuation Method I Cost/Market Cost/Market
r "--"- --' --- ........_...c._
Number of Buildings I 1 I 1
Depreciated Bldg Value j $68,637 64,344
bep .. ...,_.............. $1,750re ............. ...,.. elated EXFT Value ...._.....,,..._....._...,.._..,-..,-.,.,........,;......,............__.,... j $1,800
1 Land Value (Market) j $31,532 j $26,372
Land Value Ag j...........
justIMa kQt /aluo- $101,g19
i.......... ..... . Portability Adj
M'
92,516
ave omea dj $18,777ug................... 8 11,083
Amend m nt 1 Adj
I so
m ....
so
Value ......... .......... .........._............ ...L.'$t33,143......... _........ '.. Assessed` 81,433
Tax Amount without SOH: $1,041.19
ZQI Tex Bill Amount $819.02
TaX 3tir71e1lnr
Save Our Homes Savings: $222,17
JRL1 .Notice Help
Does NOT INCLUDE Nan Ad Valorem Assessments
Assessment Value ; ExemptValues Taxable Value i
83,143 50, 000 33,143; I
63,143 ' 25,004 5 1d8, I
83.143 50,000 i 33,143
83 143 } L.u.,,,,.,,..,_....,...._..........................$
83,y,43..'._..,...._..,.,,.,.,.-......._.._.._._........$so,aoo.
50,000 31,143 I
33,14$
Land
Method i pronlage Depth ( Units j Units Price Land Value
FRONT FOOT & DEPTH " — 117.00 136.00 Q $27 $31,532500
10/14/2017 12:56PM 4076340400 LISACOOK DECKERDOORS PAGE 32
RECEIVED 10/19/2017 09:07PM 4076a40400 LISACOOK DECKERDOORS
2017-10-13
qq
12:44 0264EX 4073331117 4073331117 » 4076340400 P 1/1
Zma&jWr Page 11 Of 17 NO. H0264-56099
Home Improvement Agreement
PLEASE READ THIS
Important additlonai Information rogarding Customer's rights may be contained in an attached State Supplement,
Sae: This "Agreement" consists of this page, the following General Terms and Conditions, the Invoice, the State
Supplement if applicable, and any drawings or Change Orders expressly made a part of this Agreement. The Agreement ie
between the Customer identified on the Invoice and The Home Depot_ Any installation Services provided under this
Agreement shall be performed by a licensed ana insured third party Authorized Service Provider. The Home Depot does not
perform architectural or engineering services, nor does it make structural changes to dwellings or other structures. The Home
De )ot and its Authorized Service Provider will perform installation services in accordance with applicable law,
Payment Schedule: Payment is required immediately as follows:
Payment' S_ 11 Rtl 34 Gus it, full immediately.
Salo% Tax: $ If applicable.
Total Amount of Sale: $ 11 FSf1_R4 Includes all applicable discounts, rebates, and
taxes. Excludes finance changes.'
Any interest payments or other finance charges will be determined by Customer's separate cardholder or loan agreement, to which The
Hume Depot is NOT a party, and will be in atldltion to Customer's payment under this Agreement. Customer ly subiact to the terms and
condiliuns of the cardholder or loan agreement, as applicable. No funds should be made payable to Authorized Service Provider;
however, Authorized Sarvice Provider may collect Customer's payment(s) mode payable to The Home Uepot.
Anticipated Doll+mry / In tallation Sch®duta
TB(? .. start Date, 10/13/2017 Fin;sh pate: 11 /1212017. Acceolprloe and Authorization: Customer
authorizes The Home Depot to order and arrange for the delivery of all goods and services included on
the Invoice. Customer further agrees and understands that this Agreement iS the entire agreement between Customer and
The Home Depot with regard to said goods and services and supersedes all prior discussions and agreernents, either
oral or written relating to said goods and services. This Agreement can not be assigned or amended except
by a writing signed by Customer and The Home Depot_ Customer acknowledges and agrees that Customer haS read,
understands, voluntarily accepts the terms of and Is entitled to and has received a complete copy of this Agreement at
thH time Customer signs the Agreement. Installatlon Professional'a license number and permitting information may need to
be provided later and as such this information may be omitted at the time ChIS Agreement is eigncd. Electronic Signature: Theparties
to the Agreement agree that the digital signatures of the parties Included in this Agreement are inten0ed to
authenticate this writing and to have the same force and effect as the use of manual signatures. Customer acknowledges that he
or she is the person named on The Home Depot contract number identified on the point of sale device, CANCELLATIQN: CUSTOMER
MAY CANCEL
THIS AGREEMENT WITHOUT PENALTY OR OBLIGATION BY DELIVERING WRITTEN
NOTICE TO THE HOME DEPOT BY MIDNIGHT ON THE THIRD BUSINESS DAY AFTER
SIGNING THIS AGREEMENT. THE STATE SUPPLEMENT ATTACHED HERETO CONTAINS A
FORM TO USE IF ONE IS SPECIFICALLY PRESCRIBED BY LAW IN CUSTOMER'S
STATE, Under such circumstances, Customer's payment(s) will be returned within tan (10) business days after The
Home Depot's receipt of Customer's notice. Authpn7e.d Servnt:"rr (
Ivt f a Futl Susimmarrrado Name. Addresoand I fvzwn Np nr
No(s),. u1i appliaam, License Nuts). Atimorizod Service
Pr 10/
13/2017 DEAR
AseociQto'glAutnorized Service
Providers
Full Signiarum date -- Assooiete: Please print
your
881e5perg6rra lrcenso number Ir applklabto. hinme Uapot USA. Inc.,
24M Pacon r„Ryxoad, N.W., Bldg 5.3, AliBnCa, Georgia 50335 912011 Page 11 Of
17
No. H0264-56099 Customer Copy
Y,2/7/7/ srcl nc,+e.
220 7 eAOIZIUAM( 4y
54171 tdi CL . 37-77/
Replau- Dwr UAi&
Opening will meet 35 PSF +/- requirement
n
mr02,WaC-o
ZC=mSZcnM
MZ2o-<2-4- Za>
a c o70o°ci D 2T-i70 O7'i
i, y - 0nZD=00m M M
O Z C
Ia CD zSG)Fm<m0
mOcn-DOOS
0 o a
co, 0o M cf)
0ODZon:5 m r-
z-nn0M-M
W
p
D
j)
7mg
O
0
O
O T Mp O n m 0 Z Z m
nCZ/) rm-z M O
00M> 0
r2In-Imam
fnZq= 000
oM-Dzm)Zo Z
m
m(n M> >D
4
Florida Building Code Online https://www.floridabuilding.org/pr/pr app_dtl. aspx? param=w GE...
em
WO
I£tn1F,u rat•iy BCIS Home Log In User Registration HotTopics Submit Surcharge S[ats &Facts Publications i FBC Staff j BCIS Site Map Links - Search
Businessr ) 1! ProductProfessionalUSER: Public User
vai
I ,,( a w'"ii.l.0 t
PrQduct_Appru_v_a.l Menp > Product_or_Apyli.ation Search > Application List > Application Detail
FL # FL8228-R7
Application Type Affirmation
Code Version 2014
Application Status Approved
Comments
Archived
Product Manufacturer Masonite International
Address/Phone/Email 1955 Powis Road
West Chicago, IL 60185
615)441-4258
sschreiber@masonite.com
Authorized Signature Steve Schreiber
sschreiber@masonite.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Exterior Doors
Subcategory Swinging Exterior Door Assemblies
Compliance Method Certification Mark or Listing
Certification Agency National Accreditation & Management Institute
Validated By National Accreditation & Management Institute,
Referenced Standard and Year (of Standard) Standard Year
ASTM E1886 2002
ASTM E1996 2002
ASTM E330 2002
TAS 202 1994
Equivalence of Product Standards
Certified By
RK I affirm that there are no changes in the new Florida
Building Code which affect my product(s) and my product(s)
are in compliance with the new Florida Building Code.
Documentation from approved Evaluation or Validation Entity C Yes 17 No r N/A
1 of 5 1 6/29/2015 6:07 PM
Florida Building Code Online https://www.floridabuilding.org/pr/pr—app_dti.aspx?param=wGE...
Product Approval Method Method 1 Option A
Date Submitted 04/29/2015
Date Validated 04/29/2015
Date Pending FBC Approval
Date Approved 05/04/2015
Summary of Products
i..... FL # Model, Number or Name i Description
18228.1 j Fiberglass Side -Hinged Door Unit i 6'-8" Opaque I/S and O/S Single Door
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: Yes FL8228 R7 C CAC NI006900.01.odf
Approved for use outside HVHZ: Yes i Quality Assurance Contract Expiration Date
Impact Resistant: Yes 12/31/2020
Design Pressure: +85.0/-85.0 j Installation Instructions
Other: Evaluated for use in locations adhering to the j FL8228 R7 11 FL01.60Dx.pdf
Florida Building Code including the High Velocity Hurricane Verified By: National Accreditation & Management
Zone, and where pressure requirements as determined by Institute
ASCE 7, does not exceed the.design pressures listed. 3'-0" Created by Independent Third Party:
x 6'-8" max nominal size. Hurricane protective system Evaluation Reports
required in HVHZ, but not required in the Wind Borne FL8228 R7 AE 504A.odf
Debris Region. See DWG-MA-FLO160-07 for additional I Created by Independent Third Party: Yes
information. I
18228.2 Fiberglass Side -Hinged Door Unit 8'-0" Opaque I/S and O/S Single Door
F._......_..................__...__........................._..........................................
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: Yes FL8228 R7 C CAC N1006900.02.odf
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Quality Assurance Contract Expiration Date
12/31/2020
Design Pressure: +70.0/-70.0 1 Installation Instructions
Other: Evaluated for use in locations adhering to the FL8228 R7 11_FL0161Dx.pdf
Florida Building Code including the High Velocity Hurricane j Verified By: National Accreditation & Management
Zone, and where pressure requirements as determined by j Institute
i ASCE 7, does not exceed the design pressures listed. 3'-0" Created by Independent Third Party:
x 8'-0" max nominal size. Hurricane protective system Evaluation Reports
required in HVHZ, but not required in the Wind Borne FL8228 R7 AE 503A.odf
Debris Region. See DWG-MA-FLO161-07 for additional i Created by Independent Third Party: Yesinformation.
18228.3 Fiberglass Side -Hinged Door Unit
1
6'-8" Opaque Inswing Single or Double Door w/or w/o
j Sidelitesa...................................._
i Limits of Use Certification Agency Certificate
Approved for use in HVHZ: Yes
jApproved for use outside HVHZ: Yes FL8228 R7 C CAC NI0.0...69-.00.01_.pdf
Quality Assurance Contract Expiration Date
j Impact Resistant: Yes 12/31/2020
I Design Pressure: +50.5/-50.5 I Installation Instructions
Other: Evaluated for use in locations adhering to the j FL8228. 11_FL01.60Dx.pdf
Florida Building Code including the High Velocity Hurricane
Zone, and where requirements as determined by
Verified By: National Accreditation & Management
Institutepressure
ASCE 7, does not exceed the design pressures listed. 12'-0" j Created by Independent Third Party:
x 6'-8" max nominal size. Hurricane protective system Evaluation Reports
I required in HVHZ, but not required in the Wind Borne FL8228_ R7 AE 502A._pd.f
Debris Region. See DWG-MA-FLO160-07 for additional I Created by Independent Third Party: Yes
i information.
j......_..............._._........._...._........................_..........__................. __............................................................. ............_.._...._............... ...............
8228.4 Fiberglass Side -Hinged Door Unit 6'-8" Opaque Outswing Single or Double Door w/ or w/o
i Sidelites
j Limits of Use Certification Agency Certificate
Approved for use in HVHZ: Yes 1 FL8228 R7 C CAC NI006900.01.1)dfIApprovedforuseoutsideHVHZ: Yes I Quality Assurance Contract Expiration Date
Impact Resistant: Yes I 12/31/2020
Design Pressure: +55.0/-50.5 j Installation Instructions
Other: Evaluated for use in locations adhering to the j FL8228 R7 II FL0160Dx.i)df
Florida Building Code including the High Velocity Hurricane
Zone, and where pressure requirements as determined by
i Verified By: National Accreditation & Management
Institute
j ASCE 7, does not exceed the design pressures listed. 12' 0" Created by Independent Third Party:
x 6'-8" max nominal size. Hurricane protective system i Evaluation Reports
required in HVHZ, but not required in the Wind Borne FL8228 R7 AE 502A.odf
Debris Region. See DWG-MA-FLO160-07 for additional Created by Independent Third Party: Yes
information.
2 of 5 6/29/2015 6:07 PM
Florida Building Code Online https://www.floridabuilding.org/pr/pr_app_dti.aspx?param=wGE...
I18228.5 ! Fiberglass Side -Hinged Door Unit ; 8'-0" Opaque Inswing Single or Double Door w/ or w/o
Sidelites
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: +50.5/-50.5
Other: Evaluated for use in locations adhering to the
Florida Building Code including the High Velocity Hurricane
Zone, and where pressure requirements as determined by
ASCE 7, does not exceed the design pressures listed. 12'-0"
x 8'-0" max nominal size. Hurricane protective system
required in HVHZ, but not required in the Wind Borne
Debris Region. See DWG-MA-FLO161-07 for additional
information.
8228.6 Fiberglass Side -Hinged Door Unit
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: +55.0/-50.5
Other: Evaluated for use in locations adhering to the
Florida Building Code including the High Velocity Hurricane
Zone, and where pressure requirements as determined by
ASCE 7, does not exceed the design pressures listed. 12'-0"
x 8'-0" max nominal size. Hurricane protective system
required in HVHZ, but not required in the Wind Borne
Debris Region. See DWG-MA-FLO161-07 for additional
information.
8228.7 i Fiberglass Side -Hinged Door Unit
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +52.0/-52.0
Other: Evaluated for use in locations adhering to the
Florida Building Code including the High Velocity Hurricane
Zone, and where pressure requirements as determined by
ASCE 7, does not exceed the design pressures listed. 12'-0"
x 6'-8" max nominal size. Hurricane protective system
required in HVHZ and the Wind Borne Debris Region. See
DWG-MA-FLO162-07 for additional information.
8228.8 1 Fiberglass Side -Hinged Door Unit
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +55.0/-55.0
Other: Evaluated for use in locations adhering to the
Florida Building Code including the High Velocity Hurricane
Zone, and where pressure requirements as determined by
ASCE 7, does not exceed the design pressures listed. 12'-0"
x 6'-8" max nominal size. Hurricane protective system
required in HVHZ and the Wind Borne Debris Region. See
DWG-MA-FLO162-07 for additional information.
8228.9 Fiberglass Side -Hinged Door Unit
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +40.0/-45.0
Other: Evaluated for use in locations adhering to the
Florida Building Code including the High Velocity Hurricane
Zone, and where pressure requirements as determined by
ASCE 7, does not exceed the design pressures listed. 12'-0"
x 8'-0" max nominal size. Hurricane protective system
required in HVHZ and the Wind Borne Debris Region. See
Certification Agency Certificate
FL8..228_R7_C CAC_ NI006900..02.pdf
Quality Assurance Contract Expiration Date
12/31/2020
Installation Instructions
FL8228 R7 II FL0161Dx.odf
Verified By: National Accreditation & Management
Institute
Created by Independent Third Party:
Evaluation Reports
FL8228_.R..7 AE 501A.,pdf
Created by Independent Third Party: Yes
8'-0" Opaque Outswing Single or Double Door w/ or w/o
Sidelites
Certification Agency Certificate
FL8228 R7 C CAC NI006900.02.pdf
Quality Assurance Contract Expiration Date
12/31/2020
Installation Instructions
FL8228 R7 II FL0161Dx.pdf
Verified By: National Accreditation & Management
Institute
Created by Independent Third Party:
Evaluation Reports
FL8228 R7 AE 501A.pdf
Created by Independent Third Party: Yes
6'-8" Glazed Inswing Single or Double Door w/ or w/o
Sidelites
Certification Agency Certificate
FL.8228_._R7..._C_._CAC .._._NI006900.03.pdf
Quality Assurance Contract Expiration Date
12/31/2020
Installation Instructions
FL8228 R7 II F'L0162Dx.pdf
Verified By: National Accreditation & Management
Institute
Created by Independent Third Party:
Evaluation Reports
FL8228R 7._ :AE...._502A. pdf
Created by Independent Third Party: Yes
6-8" Glazed Outswing Single or Double Door w/ or w/o
Sidelites
Certification Agency Certificate
FL8228_R7_C_CAC _N? O.06!N.0.._0.3,pdf
Quality Assurance Contract Expiration Date
12/31/2020
Installation Instructions
FL8228R7_II,_FL0162Dx.pdf
Verified By: National Accreditation & Management
Institute
Created by Independent Third Party:
Evaluation Reports
FL8228_R7_AE_502A.pdf
Created by Independent Third Party: Yes
8'-0" Glazed Inswing Single or Double Door w/ or w/o
Sidelites
Certification Agency Certificate
FL8.2..28_R7 C_CAC__NL0..06900,_04.,.pdf
Quality Assurance Contract Expiration Date
12/31/2020
Installation Instructions
FL8228----
Verified By: National Accreditation & Management
Institute
Created by Independent Third Party:
Evaluation Reports
FL8228 R7_AE_50.1_A.pdf
3 of 5 6/29/2015 6:07 PM
Florida Building Code Online https://www.floridabuiIding.org/pr/pr_app_dtl.aspx?param=wGE...
DWG-MA-FLO163-07 for additional information
8228.10 Fiberglass Side -Hinged Door Unit
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +43.0/-47.0
Other: Evaluated for use in locations adhering to the
Florida Building Code including the High Velocity Hurricane
Zone, and where pressure requirements as determined by
ASCE 7, does not exceed the design pressures listed. 12'-0"
x 8'-0" max nominal size. Hurricane protective system
required in HVHZ and the Wind Borne Debris Region. See
DWG-MA-FLO163-07 for additional information.
8228.11 Fiberglass Side -Hinged Door Unit
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: +52.0/-52.0
Other: Evaluated for use in locations adhering to the
Florida Building Code not including the High Velocity
Hurricane Zone, and where pressure requirements as
determined by ASCE 7 do not exceed the design pressures
listed. 12'-0" x 6'-8" max nominal size. See DWG-MA-
FL0162-07 for additional information.
8228.12 I Fiberglass Side -Hinged Door Unit
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: +55.0/-55.0
Other: Evaluated for use in locations adhering to the
Florida Building Code not including the High Velocity
Hurricane Zone, and where pressure requirements as
determined by ASCE 7 do not exceed the design pressures
listed. 12'-0" x 6'-8" max nominal size. See DWG-MA-
FL0162-07 for additional information.
8228.13 ; Fiberglass Side -Hinged Door Unit
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: +40.0/-45.0
Other: Evaluated for use in locations adhering to the
Florida Building Code not including the High Velocity
Hurricane Zone, and where pressure requirements as
determined by ASCE 7 do not exceed the design pressures
listed. 12'-0" x 8'-0" max nominal size. See DWG-MA-
FL0163-07 for additional information.
8228.14 Fiberglass Side -Hinged Door Unit
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: +43.0/-47.0
Other: Evaluated for use in locations adhering to the
Florida Building Code not including the High Velocity
Hurricane Zone, and where pressure requirements as
determined by ASCE 7 do not exceed the design pressures
listed. 12'-0" x 8'-0" max nominal size. See DWG-MA-
FL0163-07 for additional information.
Created by Independent Third Party: Yes
8'-0" Glazed Outswing Single or Double Door w/ or w/o
Sidelites
Certification Agency Certificate
F18228_R7 C_CAC_NI006900.04.pdf
Quality Assurance Contract Expiration Date
12/31/2020
Installation Instructions
FL8228 R7 II FL0163Dx.pdf
Verified By: National Accreditation & Management
Institute
Created by Independent Third Party:
Evaluation Reports
FL...82.2.8_R7_AE 501Apdf
Created by Independent Third Party: Yes
6'-8" Impact Glazed Inswing Single or Double Door w/ or
w/o Sidelites
Certification Agency Certificate
FL8228 R7 C CAC NI006900.05.pdf
Quality Assurance Contract Expiration Date
12/31/2020
Installation Instructions
FL8228 R7 II FL0162Dx.i3d_f
Verified By: National Accreditation & Management
Institute
Created by Independent Third Party:
Evaluation Reports
FL8228_R:7_.A...E_50.2A._p..df
Created by Independent Third Party: Yes
6'-8" Impact Glazed Outswing Single or Double Door w/ or
w/o Sidelites
Certification Agency Certificate
FL8228_R7 C_CAC NI006900;O5.pdf
Quality Assurance Contract Expiration Date
12/31/2020
Installation Instructions
FL8228 R7 _.I1_FL01_62 Dx. pdf Verified
By: National Accreditation & Management Institute
Created
by Independent Third Party: Evaluation
Reports FL8228_
R7_AE_502A...Pdf Created
by Independent Third Party: Yes 8'-
0" Impact Glazed Inswing Single or Double Door w/ or w/
o Sidelites Certification
Agency Certificate FL8228_
R7_C_CAC_N I006900. 06_.p_dfQuality
Assurance Contract Expiration Date 12/
31/2020 Installation
Instructions F_
L..8228 .R-.7II FL0.1...63_Dx..pdf Verified
By: National Accreditation & Management Institute
Created
by Independent Third Party: Evaluation
Reports FL8228._
R7__A E_50.1_A..pc1f Created
by Independent Third Party: Yes 8'-
0" Impact Glazed Outswing Single or Double Door w/ or w/
o Sidelites Certification
Agency Certificate FL8228
R7 C CAC NI006900.06,pdf Quality
Assurance Contract Expiration Date 12/
31/2020 Installation
Instructions FL8228_
R7 II FL0163Dx_pdf Verified
By: National Accreditation & Management Institute
Created
by Independent Third Party: Evaluation
Reports FL8228
R7 AE 501A.odf 4
of 5 6/29/2015 6:07 PM
NOTICE OF PRODUCT CERTIFICATION
Company: Masonite International Corporation Certification No.: NI006900.03
1955 Powis Road Certification Date: 01/14/2007
West Chicago, IL 60185 Expiration Date: 12/31/2020
Revision Date: 11/21/2014
Product: Fiberglass Glazed Inswing or Outswing Door w/ and w/o Non -Impact Rated Sidelites
w/Wood Frame unless noted)
Specification: TAS 202/ASTM E330
The "Notice of Product Certification" is only valid if the NAMI Certification Label has been applied to the product as described within this document. The certification
label represents product conformity to the applicable specification and that all certification criteria has been satisfied. This product has been approved for listing within
NAMI's Certified Product Listing at wr,Nv.N_amic_ertification.com. NAMI's Certification Proeram is accredited by The American National Standards Institute fANSII.
Inswing Glazed Structural Water Missile Test Report Number
Configuration or or Maximum Design Test Impact Drawing Number &
Outswing Opaque Size Pressure Pressure Rated Comments
X I/S Glazed 3'0" x 6'8" 52/-52 2.86 psf No NCTL-210-3108-1/CTLA-805W-2
Single Maximum Panel Size: 3'0" x 6'8"
Anchor Detail-MA-FL0162-07
X O/S Glazed 3'0" x 6'8" 55/-55 6.00 psf No NCTL-210-3108-1/CTLA-805W-2
Single 8.25 psf* Maximum Panel Size: 3'0" x 6'8"
Anchor Detail-MA-FL0162-07
XX I/S Glazed 6'0" x 6'8" 52/-52 2.86 psf No NCTL-210-3108-1/CTLA-805W-2
Double Maximum Panel Size: 3'0" x 6'8"
Anchor Detail-MA-FL0162-07
XX O/S Glazed 6'0" x 6'8" 55/-55 6.00 psf No NCTL-210-3108-1/CTLA-805W-2
Double 8.25 psf* Maximum Panel Size: 3'0" x 6'8"
Anchor Detail-MA-FL0162-07
XO/OX I/S Glazed Door 6'0" x 6'8" 52/-52 2.86 psf Door -No NCTL-210-3108-1/CTLA-805W-2
Single w/Sidelite Glazed Sidelite Sidelite-No Maximum Panel Size: 3'0" x 6T'
Anchor Detail-MA-FL0162-07
XO/OX O/S Glazed Door 6'0" x 6'8" 551-55 6.00 psf Door -No NCTL-210-3108-1/CTLA-805W-2
Single w/Sidelites Glazed Sidelite 8.25 psf* Sidelite-No Maximum Panel Size: 3'0" x 6'8"
Anchor Detail-MA-FL0162-07
OXO I/S Glazed Door 910" x 6'8" 52/-52 2.86 psf Door -No NCTL-210-3108-1/CTLA-805W-2
Single w/Sidelites Glazed Sidelites Sidelites-No Maximum Panel Size: 3'0" x 6'8"
Anchor Detail-MA-FL0162-07
OXO O/S Glazed Door 910" x 6'8" 55/-55 6.00 psf Door -No NCTL-210-3108-1/CTLA-805W-2
Single w/Sidelites Glazed Sidelites 8.25 psf* Sidelites-No Maximum Panel Size: 3'0" x 6'8"
Anchor Detail-MA-FL0162-07
OXXO I/S Glazed Doors 12'6" x 6'8" 52/-52 2.86 psf Doors -No NCTL-210-3108-1/CTLA-805W-2
Double w/Sidelites Glazed Sidelites Sidelites-No Maximum Panel Size: 3'0" x 6'8"
Anchor Detail-MA-FL0162-07
OXXO O/S Glazed Doors 12'6" x 6'8" 55/-55 6.00 psf Doors -No NCTL-210-3108-1/CTLA-805W-2
Double w/Sidelites Glazed Sidelites 8.25 psf* Sidelites-No Maximum Panel Size: 3'0" x 6'8"
Anchor Detail-MA-FL0162-07
Denotes High Dam Threshold Design
National Accreditation & Management Institute, Inc./4794 George Washington Memorial Highway/Hayes, VA 23072
Tel: (804) 684-5124/Fax: (804) 684-5122
NAMI AUTHORIZED SIGNATURE:
Luis R. Lomas P. E.
1432 Woodford Rd. Manufacturer: Masonite
Lewisville, NC 27023 Report #: 502A
336-945-9695 Date: 12/29/09
Product: Double Door with sidelites 12'x6'8"
Scope:
This analysis provides calculations, quantities, and spacing requirements for installing product to substrate, and it applies
only to the product described herein. These calculations comply with requirements of the Florida Building Code.
Drawings verification:
This analysis verifies anchoring for the following drawings
DWG-MA-FLO120-05 DWG-MA-FL0132-05 DWG-MA-FLO147-06 DWG-MA-FLO162-07
DWG-MA-FLO122-05 DWG-MA-FLO134-05 DWG-MA-FLO151-06 DWG-MA-FLO168-07
DWG-MA-FLO124-05 DWG-MA-FLO140-05 DWG-MA-FLO153-06 DWG-MA-FLO170-07
DWG-MA-FLO126-05 DWG-MA-FLO142-05 DWG-MA-FLO155-06 DWG-MA-FLO172-07
DWG-MA-FLO128-05 DWG-MA-FLO143-05 DWG-MA-FLO156-06 DWG-MA-FLO174-07
DWG-MA-FLO130-05 DWG-MA-FLO146-06 DWG-MA-FLO160-07 DWG-MA-FLO175-07
Anchors to be qualified:
1. #10 Wood screw, for installation in wood frame substrates.
2. 3116" ITW Tapcon, for masonry installation
Anchor capacity in shear condition:
Fastener type: #10 wood screw
Side member: Douglas Fir -Larch
Side member thickness: t, = 1.000 in
NDS 2005,11.3)
Main member: Spruce -Pine -Fir
Main member thickness: tm= 1.500 in
Side member dowel bearing strength: Fe, = 4,650 psi Main member dowel bearing strength: F_ = 3,350 psi
Minimum required penetration: 1.330 in Screw bending yield strength: Fib = 80,000 psi
Duration Factor: Co = 1.6 Tabulated lateral design value: Z= 107.0 Ibs
Allowable Design Value: Z'= 171 Ibs/anchor Mode IV
Fastener type: 3/16" ITW Tapcon N.O.A. 07-1126.10
Substrate: Hollow block
Minimum embedment: 1.25 in
Minimum edge distance: 1.13 in Minimum C to C spacing: 2.25 in
Tabulated shear design value: Z = 112 Ibs Actual C To C spacing: 3.00 in
Minimum edge distance: 2.63 in C to C spacing factor: 1.00
Tabulated shear design value: Z = 197 Ibs
Actual edge distance: 2.50 in
Design value per interpolation: Z = 189 Ibs
Allowable Design Value: Z'= 189 Ibs/anchor
Minimum anchor capacity: 171 Ibs/anchor
Note: Anchors with the least capacity is used for calculations to qualify anchors with higher capacity.
Anchor calculations, minimum required anchors
Double. Pressure against stops with bump threshold:
36.38 36.38 Design pressure: 60.0 psf
Al Al
A2Y YAz i 79.25
Al AAll
72.75
1 of 4
Zone
Area
zft)
Load
Ibs)
Ind.
in)
Max.
O.C.
in)
Anchor
ResultCap.
Ibs) QtY
Load
Ibs)
Al 2.3 138 N/A N/A 171 1 138 OK
A2 7.7 463 6.00 21.00 171 5 93 OK
A3 7.7 463 N/A N/A 171 3 154 OK
Luis R. Lomas P.E.
FL No.: 62514
1 /7/2010
Luis k Lomas P. E.
1432 Woodford Rd.
Lewisville, NC 27023
336-945-9695
Double. Pressure away from stops:
36.38 36.38
2
Al - - Al
79.25
Manufacturer: Masonite
Report #: 502A
Date: 12/29/09
Desiqn pressure: 60.0 psf
Max. AnchorAreaLoadInd.
Cap, Qty
LoadZone
Utz) Ibs) in)
O.C. Result
in) Ibs) Ibs)
At 10.0 601 6.00 21.00 171 5 120 OK
Az 10.0 601 N/A N/A 171 4 150 OK
72.75
Double. Pressure against stops with saddle threshold:
36.38 36.38
MAl ',
Al -
3
A2 - Y2
79.25
Desion pressure: 60-0 psf
Zone Area2ft)
Load
Ibs)
Ind.
in)
Max.
O.C.
in)
Anchor
ResultCap.
Ibs) Q
Load
Ibs)
At 2.3 138 N/A N/A 171 1 138 OK
A 8.9 532 6.00 21.00 171 5 106 OK
A3 7.7 463 N/A N/A 171 3 154 OK
A4 10.0 601 N/A N/A 171 4 1 150 OK72.75
Double with sidelites. Pressure against stops with bump threshold:
37.50 36.38 36.38 37.50
Al A4 A4 Al
U
A2 A
Al A4 A4 Al
79.25
147.75
Double with sidelites. Pressure away from stops:
37.50 36.38 36.38 37.50
A2Y- 3
1
3 YA2 79.25
3 3
Al Al _
Desiqn pressure: 60.0 psf
Zone
Area
zft)
Load
Ibs)
Ind.
in)
Max.
O.C.
in)
Anchor
ResultCap.
Ibs) Q
Load
Ibs)
Al 2.4 146 N/A N/A 171 1 146 OK
AZ 7.9 473 6.00 21.00 171 5 95 OK
A3 7.8 468 N/A N/A 171 3 156 1 OK
A4 2.3 138 N/A N/A 171 1 138 OK
A5 7.7 463 N/A N/A 171 3 154 OK
Desion pressure: 60.0 psf
Zone
Area
Zft)
Load
Ibs)
Ind.
in)
Max.
O.C.
in)
Anchor
ResultCap.
Ibs) Q
Load
Ibs)
AI 2.4 146 N/A N/A 171 1 146 OK
Az 7.9 473 6.00 21.00 171 5 95 OK
A3 8.9 537 N/A N/A 1 171 4 134 OK
A4 10.0 601 N/A N/A 1 171 1 4 1 150 1 OK
147.75
Double with sidelites. Pressure against stops with saddle threshold:
Desiqn pressure: 60.0 psf
37.50 36.38 36.38 37.50
Y_ 6 Y_
Al
3Y
7
Al Al
79.25
1
147.75
2of4
Zone
Area
Zft)
Load
Ibs)
Ind.
in)
Max.
O.C.
in)
Anchor
ResultCap.
Ibs) Qty
Load
lb
Al 2.4 146 N/A N/A 171 1 146 OK
A2 7.9 473 6.00 21.00 171 5 95 OK
A3 1 7.8 468 1 N/A N/A 171 3 156 OK
A4 8.9 537 N/A N/A 171 4 134 OK
A 2.3 138 N/A N/A 171 1 138 OK
A6 7.7 463 N/A N/A 171 3 154 OK
A, 10.0 601 N/A I N/A 1 171 1 4 150 1 OK
Luis R. Lomas P.E.
FL No.: 62514
1 /7/2010
3of4
Luis R. Lomas P. E.
1432 Woodford Rd. Manufacturer: Masonite
Lewisville, NC 27023 Report #: 502A
336-945-9695 Date: 12/29/09
Anchor Locations: Double door with sidelites
r
Note:
Anchor locations indicated in this document are the minimum required for the described product exposed at the design
pressure indicated herein.
E IV
TAT OF
jOlt 4A1-'\`
WH
Luis R. Lomas P.E.
FL No.: 62514
1/7/2010
Luis R. Lomas P. E.
4 of 4
1432 Woodford Rd. Manufacturer: Masonite
Lewisville, NC 27023 Report #: 502A
336-945-9695 Date: 12/29/09
Anchor Locations: Double door
6.00 TYP. - -
I
I 6.00
l
13.45
MAX.. O.C.
79.25
I
6.00
1
36.38 -L- 36.38
6.00 TYP. - -- 18.19 TYP.
3.00 TYP. --- -
Note:
Anchor locations indicated in this document are the minimum required for the described product exposed at the design
pressure indicated herein.
0 51
Luis R. Lomas P.E.
FL No.: 62514
1 /712010
J 149" MAX. OVERALL FRAME WIDTH 00
C/Cl i l) 1 ?"' ,,
36.375" MAX. O COSIDEHINGEDFIBERGLASSDOORUNIT -
PANEL WIDTH - 37.5" MAX. Q O6'-8" GLAZED DOUBLE DOOR WITH / WITHOUT SIDELITES
00 -
D.L.o. -
FRAME vIDTH -' zW/ASTRAGAL I~ O i
H
GENERAL NOTES Q c
1. EVALUATED FOR USE IN LOCATIONS ADHERING TO l.Ll O QTHEFLORIDABUILDINGCODEAND 'WHERE PRESSURE
REQUIREMENTS AS DETERMINED BY ASCE 7, MINIMUM I
I Z n- UDESIGNLOADSFORBUILDINGSANDOTHERSTRUCTURES,
DOES NOT EXCEED THE DESIGN PRESSURES LISTED. - I ! LL Lc) J
2. WHEN INSTALLED IN THE HIGH VELOCITY HURRICANE ZONE (HVHZ), ~ L0
HURRICANE PROTECTIVE SYSTEM (SHUTTERS) IS REQUIRED.
co
H-
3. WHEN INSTALLED IN THE WIND-BORNE DEBRIS REGION, X WEXCLUDINGTHEHIGHVELOCITYHURRICANEZONE (HVHZ), _ ¢ p = Q
HURRICANE PROTECTIVE SYSTEM IS NOT REQUIRED ON w `
PANELS WITH IMPACT GLASS, BUT IS REQUIRED ON PANELS = C _ WITH NON -IMPACT GLASS.
4. POLYURETHANE CORE FLAME SPREAD INDEX OF 50 - Z
AND SMOKE DEVELOPED INDEX OF 60 PER ASTM E84. ` a
POLYSTYRENE CORE FLAME SPREAD INDEX OF 15 '<
AND SMOKE DEVELOPED INDEX OF 115 PER ASTM E84.
5. PLASTICS TESTING OF FIBERGLASS FACING: ono 'oN-.Nw-JTESTDESCRIPTIONDESIGNATIONRESULT
o ao^m wLI
omo 5 If
6. PLASTICS TESTING OF LITE FRAME MATERIAL:
TEST DESCRIPTION DESIGNATION RESULT O s
DOUBLE DOOR UNIT W/SIDELITES a i
AddHdun 10 NAMI n n n n
333imCfiIUEIc21mHD.: N(o a v 00 - /L l _ N V1 N to
COMPARATIVE TENSILE STRENGTH AFTER WEATHERING Dyte - Z I_ C
4500 HOURS XENON ARC METHOD 1 9 / , 0 Z Z
7, IMFACT GLAZING LAMINATE MIAMI DADE BCCO NOA 09-0127.13. < W ¢
R
UUD_V O ZD O
LLJIaNZ0 >
J--a wILL-1
00LJ
NNIa
SINGLE DOOR UNIT DOUBLE DOOR UNIT SINGLE DOOR UNIT SINGLE DOOR UNIT SINGLE DOOR UNIT ¢_/SIDELITES DOUBLE DOOR UNIT W/SIDELITES
WITH SIDELITE WITH SIDELITE o um ¢ Z
TABLE OF CONTENTS DATE: 1/5/07
h TANCHORING DESCRIPTION /- ( `f scaL[: N.T.S.
PICAL ELEVATIONS & GENERAL NOTES+52.0-7DwG. er: $Wc
LOCATIONS & DETAILS HK. BT:
CHORING LOCATIONS & DETAILS KURT SALTHAZOR DruwlNc no.: FLORIDA P.E.
High Dom Threshold Design 56533 DWG-MA-FLO162-07
SHEET 1 OF 3
SELF IGNITION TEMP ASTM D1929 752 'F > 650 'F
RATE OF BURNING ASTM 0635 0.56 IN/MIN
SMOKE DENSITY ASTM D2843 53.4%
TENSILE STRENGTH" ASTM D638 3.2% DIFF
SELF IGNITION TEMP ASTM D1929 740 'F > 650 'F
RATE OF BURNING ASTM 0635 0.77 IN/MIN
SMOKE DENSITY ASTM 02843 13.4%
TENSILE STRENGTH' ASTM D638 7.50% DIFF
DESIGN PRESSURE RATING
WHERE WATER INFILTRATION PERFORMANCE IS
REQUIRED TO BE 15% OF DESIGN PRESSURE
CONFIG MAX WIDTH INSWING OUTSWING INSWING OUTSWING DUTSIM1'ING•
X 37.5 52.0 -52.0 55.0 -55.0 19.0 -19.0 40.0 -40.0 55.0 -55.0
XX 74 52.0 55.0 19.0 -19.0 40.0 -40.0 55.0 -55.0
OX or XO 75 52.0 -52.0 55.0 -55.0 79.0 -19.0 40.0 -40.0 55.0
OXO 112.5 52.0 -52.0 55.0 -55.0 19.0 -79.0 40.0 -40.0 55.0 -55.0
OXXO 149 52.0 -520 55.0 -SS.0 19.0 -19.0 140.0 -40.0 56.0 -55.0
SEE DETAIL — 6'
E" 3.,
3" 3"
3.. I_ r _
3..
c 3 g
SEE DETAIL
I I I I —I 6'•
0
U
a
N
J
Q
a
w B
J
B f
I III I II I
3 Y "
3
3`
E
3 3,. — "
SEE DETAIL
F
8 x 2-1/210
x 2"" 10
x 5/8" 8
x 2-1/2" #10 x 3/4" O #
10
x 5/8" #10
x 3/4" 10
x 2 FRAME /
DOOR DETAIL "
D" DETAIL "C" TYPICAL
3"
6"
0
o
U
a
SEE DETAIL N "
D" J
qq
QYo
0w
o
N a
G 6
EE
DETAIL C"
6"
Addardo
to NAMICeticahmND;
o0 Renewed
By. '— 8x2— 1/2" DaeR.Bvew.: ) lz ASTRAGAL
RETAINER BOLT HOLE MUST
BE DRILLED THROUGH THE
THRESHOLD & INTO THE DETAIL "
E" ASTRAGAL STRUCTURE DEEP ENOUGH ATTACH
ASTRAGAL RETAINER BOLT FOR A 1.375" THROW STRIKE
PLATE TO FRAME DETAIL "F" ASTRAGAL AS
SHOWN. 0.
124' ANNEALED DECORATIVE INSERT 0.
090" SAFLE% IIIG (OPTIONAL) 00W 832 0.
124" ANNEALED — .0124' TEMP. I
0.962" DOW"
I
toa7 1.376 7s I
INSWING
THRESHOLD OUI-SWING THRESHOLD HIGH DAM 0/S THRESHCLD f
IQ6
X PHS 2 :
A..L`' DOW 832 •'R„>
t• EXTERIOR
INTERIOR XT RI R LNT RIIO TYPICAL
GLAZING DETAIL TYPICAL GLAZING DETAIL IMPACT
RATED GLASS NON —IMPACT GLASS DATE:
1/5/07 SCALE:
N. T. S. DWG.
BY: SN/S CHK.
BY: DRAWING
NC.: OWC-
MA-FLO162-07 SHEET
2 OF 3
SEE DETAIL
C" SHT. 2
ATTACHMENT DETAIL
1. ANCHOR ANALYSIS FOR LOADING CONDITIONS PREPARED,
SIGNED AND SEALED BY LUIS R. LOMAS, PE
FLORIDA #62514) WITH THE LOWEST (LEAST)
FASTENER RATING FROM THE DIFFERENT FASTENERS
BEING CONSIDERED FOR USE. JAMB, HEAD, AND
THRESHOLD FASTENERS ANALYZED FOR THIS UNIT INCLUDE
10 WOOD SCREWS OR 3/16" TAPCONS. A PHYSICAL
SHIM MUST BE PLACED IN SHIM SPACE AT EACH ANCHOR
LOCATION. TAPCON EDGE DISTANCE MIN 2-5/8".
2. MULLIONS TO BE 2-1/2" X 4-3/8" STRUCTURAL GRADE
FJ PINE ON CONTINUOUS HEAD AND SILL UNITS. BACK TO
BACK JAMB UNITS JOINED WITH 1" X 1/2" LONG
CORRUGATED FASTENERS LOCATED 3" FROM EACH END
AND MAXIMUM 7" O.C. OR #10 X 2" FLAT HEAD WOOD
SCREWS LOCATED 6" FROM EACH END AND MAXIMUM
12" O.C.
3. THE WOOD SCREW SINGLE SHEAR DESIGN VALUES COME FROM
ANSI/AF&PA NDA FOR SOUTHERN PINE LUMBER AND ACHEIVEMENT
OF 1-1 /2" MINIMUM EMBEDMENT. THE TAPCON MUST ACHIEVE
MINIMUM EMBEDMENT OF 1-1/4".
4. WOOD BUCKS BY OTHERS MUST BE ANCHORED PROPERLY TO
TRANSFER LOADS TO STRUCTURE.
5. MINIMUM DESIGN VALUE STRENGTH OF ANCHORS 171 LBS.
3" —
t
0
o ewU
a SEE DETAIL
D" SHl 2
0
a
w0_ no
G
io
i 3„
3"
I II 1 I II I
i
oWU
a-
J
D
w B
I II
J J
II II
B
II II
g
Jj
3"
HARDWARE SCHEDULE
1. KWIKSET SERIES 400 GRADE 3 CYLINDRICAL LATCH AND
SERIES 980 GRADE i DEADLOCK HARDWARE TO BE INSTALLED
AT 5-1/2" CENTERLINE.
2. 4" X 4" FULL MORTISE BUTT HINGES.
i
r— MIN _ 0.25"
SHI
CL —I (—
TYPICAL WOOD BUCK
ANCHOR INSTALLATION
MIN
0.25" MAXSHIM
CL —I (-
TYPICAL MASONRY
ANCHOR INSTALLATION
AddeMun 10 NAMI
Cedcalion No.: Ni C a 4 4 oo - rL i
ReviewedBy.
Dale A vewx:
DATE: 1/5/07
SCALE: N.T.S.
DWG. BY: SINS
l 6Y:
OF
762-0
RIEQUIO DIED IINSPIECTION SEQUENCE
B,p# I) - 7—n, k U Address: w!
BUILIDING (PERMIT
min max- Inspection Description
Footer / Setback
Stemwall
Foundation / Form Board Survey
Slab / Mono Slab Prepour
Lintel / Tie Beam / Fill / Down Cell
Sheathing — Walls
Sheathing — Roof
Roof Dry In
Frame
Insulation Rough In
Firewall Screw Pattern
Drywall / Sheetrock
Lath Inspection
Final Solar
Final Firewall
Final Roof
Final Stucco / Siding
Insulation Final
Final Utility Building
p Final Door
Final Window
Final Screen Room
Final Pool Screen Enclosure
Final Single Family Residence
Final Building (Other)
min 110Max
Electric Underground
Footer / Slab Steel Bond
Electric Rough
T.U.G.
Pre -Power Final
Electric Final
JCInsNanMax ection Descrn anon
Plumbing Underground
Plumbing Sewer
Plumbing Tub Set
Plumbing Final
1I
Inspection D ; I iP i I ,P III
Mechanical Rough
Mechanical Final
a fi • 1
v c . w lf t 4t 11J t v v L, _ a 11S'`a r'. . lcP•;;' i'l fZ• xei 3 £ ^ 1L` - .,a` ,i't .* r•.'...rSn
Inspection Description
Gas Underground
RIEVISEID: June 2014