Loading...
142 Wilson Bay Ct - M17-003024 - HVACJob Address: W,1 11'"4J / f CITY OF SANFORD BUILDING .&FIRE-PREVENTI:ON--._ PERMIT APPLICATION Parcel ID: - M :;IC7 -- _(1) Type of Work: _ New Addition Description Plan Review Contact Person: f Phone: L) -?-n :aeo Fax: Application No: — 3 o o Documented .Construction Value: $ U q ), Historic. Dtstric Y&,s 11 NO Residential dCoinmercial oration Repair Demo Change of Use Move Property Owner Information Name Phone: q 1-3 — t-110-14g 1 Street: W Resident of property? City, State Zip: , l A i Contractor Information Name Street: City, S Phone: Fax: State License Architect/Engineer Information Name: Phone: Street: Fax: City, St, Zip: E-mail: Bonding Company: Mortgage Lender: Address: Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN. ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, fur "aces, builers, healers, lauks, and air couditioners, etc. FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: 5" Edition (2014) Florida Building Code Revised: June 30, 20 i S Permit Application N(7TICG In,addition to the requirements of this permit, there may be additional restrictions applicable to this property that may befoundin, the public records of this county, and there may be additional permits required from other governmental entities such as watermanagementdistricts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires ,payment,of a plain review fee at the time of permit submittal. A_copy of the executed contract is requiredinordertocalculateaplan -review charge and will he considered the'estiniated construction_ value of the. j`oh; at the time of submittal. The actual construction value will b'e•6gurcd bhsccl on the current iCC Valuation Table in effect at.tlie time the permit is issued inaccordancewithlocal 'ordinance. Should calculated"Fcharges figured, off the executed; contract exceed the actual construction value, credit'will be applied to your permit fccs vlteit the.pefmit isIJssued. OWNER'S A:F1,1DAVIT;,I certify that all of -the foregoing- information is be done in compliance with' all applicable laws regulating construction and Signature of Owner/Agent Date Print Owner/Agent's Name Signature of Notary -State of Ptorida IDate 41j'a-t all work will 7 Date MY COMMISSION # FF:^S963 EXPIRES June 05, 2020 53 :.«a4 vuui;ySar ca;car. Owner/Agent is Personally Known to Me or Contractor/Agent is L k ersoniilly Knowlp fo Me orProducedIDTypeofIDProducedIDTypeof1D_ -= BELOW IS, FOR OFFICE USE ONLY Permits Required: Building Electrical Mechanical Plumbing[] Gas[] Roof Construction Type: Occupancy Use: Flood Zone: Total Sq Ft of Bldg: Min. Occupancy Load: # of Stories: New Construction: Electric - # of Amps, Plumbing - # of Fixtures Fire Sprinkler Permit: Yes No # of Heads APPROVALS: ZONING: ENGINEERING: COMMENTS: UTILITIES: FIRE: Fire Alarm Permit: Yes No WASTE WATER: BUILDING: Revised June 30, 2015 Permit Application SCPA Parcel View: 22-19-30-503-0000-2540 http://parceidetail. scpafl.org/ParcelDetailInfo. aspx'?PID=22193050: : Property Record Card Parcel: 22-19-30-503-0000-2540 Owner: PALMER JESSE D Property Address: 142 WILSON BAY CT SANFORD, FL 32771 Parcel Information Parcel r 22-19-30-503-0000-2540 m - Owner PALMER JESSE D Property Address ` 142 WILSON BAY CT SANFORD, FL 32771 j uMailing , 142 WILSON BAY CT SANFORD, FL 32771 Subdivision Name PRESERVE AT LAKE MONROE UNIT 2 q.,.._ i Tax District S1-SANFORD DOR Use Code €€ 01 SINGLE FAMILY Exemptions 00 HOMESTEAD(2012) f- Description SPECIAL WARRANTY DEED CERTIFICATE OF TITLE WARRANTY DEED Find Comparable Safes Land V) 0 0 0 1 Date Book 9/1/2010 07472 8/1/2010 07432 8/1/2005 05923 Value Summary j 2017 Working _ . 201 Values VaIL Valuation Method Cost/Market Cos Number of Buildings 1 1 Depreciated Bldg Value $160,919 $15 i Depreciated EXFT Value $1.750 $1,£ Land Value (Market) $34,000 $34 Land Value Ag Just/Market Value " $196.669 $18 Portability Adj Save Our Homes Adj $66.843 $623 Amendment 1 Adj P&G Adj $0 $0 Assessed Value $129,826 $12 I Tax Amount without SOH: $2,989.00 Q.t6 Tax ili Amount. $1,135.00 Tax Estimator Save Our Homes Savings: $1,254.00 TRIM Notim Help Does NOT INCLUDE Non Ad Valorem Assessments Page Amount Qualified Vac/h 0733 150,000 No _ Imprc 1836 100 No Imprc 0138 224.300 Yes Imprc Method j Frontage Depth Units i Units Price Land Value LOT 1$34,000.00 1 of 3 10/14/2017, 6:23 AM R e o:DELmA1'R Your,24 Heating - Air Conditioning - Appliances state Cert CACD32448 WW W.DELAIR.COM Sales, Agreement Jesse & Tiffany Palmer Phone Enter Date Joe Tocci, Jr. 142 Wilson Bay Ct. 813-86T-4817 Email 321-228-0079 Sanford FL 32771 t>cit"'del• ai' GQn—' Dosciipion'r ' L SEi:f2RATiNG Carrier Comfort 15 PuronO HP 4 TON 15.0 Carrier Umited Factory Warranty: 10 years all functional parts 2 years on labor. For the sum set forth we agree to install and service the following Del -Air comfort system as per the specifications outlined including the equipment and materials listed on proposal. Materials not listed are not included. Total Including Permit $ 8:,412 Terms and Conditions CWF Special Rate of 0.0% APR. 60 Equal Payments Required 4116 Homeowners are responsible to stay home forone (1) full dayfor the Building DepartmentInspection. Del -stir gives no guarantee for any existing conditions such as, but not limited to, pre-existing Electrical, Ductwork, Mechanical Equipment & House. Structure a. Wa--=c,m; FIEP a sit ACCORDING TO FLORIDA'S CONSTRUCTION LIEN LAW (SECTIONS 713.001 — 713.37, FLORIDA STATUTES), THOSE WHO WORK ON YOUR PROPERTY OR PROVIDE MATERIALS AND ARE NOT PAID IN FULL HAVE THE RIGHT TO ENFORCE THEIR CLAIM FOR PAYMENT AGAINST YOUR PROPERTY. IF YOUR CONTRACTOR OR A SUBCONTRACTOR FAILS TO PAY SUBCONTRACTORS, SUB -SUBCONTRACTORS, OR MATERIAL SUPPLIERS, THE PEOPLE WHO ARE OWED MONEY MAY LOOK TO YOUR PROPERTY FOR PAYMENT, EVEN IF YOU ALREADY PAID YOUR CONTRACTOR IN FULL. IF YOU FAIL TO PAY YOUR CONTRACTOR, YOUR CONTRACTOR MAY ALSO HAVE A LIEN ON YOUR PROPERTY. THIS MEANS IF A LIEN IS FILED, YOUR PROPERTY COULD BE SOLD AGAINST YOUR WILL TO PAY FOR LABOR, MATERIALS, OR OTHER SERVICES THAT YOUR CONTRACTOR OR A SUBCONTRACTOR MAY HAVE FAILED TO PAY. TO PROTECT YOURSELF, YOU SHOULD STIPULATE IN THIS CONTRACT THAT BEFORE ANY PAYMENT IS MADE, YOUR CONTRACTOR IS REQUIRED TO PROVIDE YOU WITH A WRITTEN RELEASE OF LIEN FROM ANY PERSON OR COMPANY THAT HAS PROVIDED TO YOU A "NOTICE TO OWNER.' FLORIDA'S ONSTRUCTION LIEN LAW IS COMPLEX, AND IT IS RECOMMENDED THAT YOU CONSULT AN ATTORNEY. Add Additional Notes Here 7 X2Signature 62047 I have the authority to order the work outlined above. Jesse & TilfanyPalrner In the event payment is not made promptly in accordance with 10I1k017 agreed terns, it shall be seller's option to charge a service Joe occi, Jr. charge not exceeding two (2) percent per month. The first service charge will be due 15 days from the date of the billing of our amount due on the job. In the event of collection by an attorney, it is understood that the title of all products and equipment covered by the all attorney fees, court costs, and other legal fees shall be borne contract remains solely in the seller until the entire purchase price has by the buyer, in the event of non-payment, purchaser agrees to beenpaid in full and the manner of installation anlor attachment to any allow seller on premises to remove equipment installed. This ouiprrient and/or any portion of the building structure in which the sales agreement shall be binding upon the heirs, successors, installation is made shall not in any manner 'eo acdize the-sellers`title. and/or, assi ns'of the RZilyWhereto. Proposal is no lotigpr valid after; 11/12/2017 Page 2 of 2 . Scanned by CamScanner r i, ur. '4 tItGU.t I G0.(lti.'( t, CUrIF'T(iILC,Et; Name: L'K 9034 1'a 14?9 (iF''s=s.} Address: CLEM S ? 117127 r7-' r hLGt)Ct Q 1 /05/ 017 11b13,22' AI'1 3277 ftii01 17C1.i° ,lidvt3i^rOTI'CE 0 ttIIMENCEMENT Permit Number: Parcel ID Number. The undersigned hereby gives notice that Improvement will be made to certain real property, and In accordance with Chapter 713, Florida Statutes, the following Information is provided in this Notice of Commencement. I OF PROPERTY: (Legal description of the property and street address if 2. GENERAL DESCRIPTION OF IMPROVEMENT: 3. OWNER INFORMATION M LESSEE INFORMATION IF THE LESSEE CONTRACTED FOR THE IMPROVEMENT: cNameandaddress:_en-Se QfnAlYt r H7. L) ,'fin ' 1 Interest in property: Qt. nf4c Fee Simple Title Holder (if other than owner listed above) Name: 4. CONTRACTOR: Name: 042.1-1 Address: b 1 CiDd:SC,(t S. SURETY (If applicable, a copy of A---. 6. LENDER: Address: payment bond is attached): Name: Phone Number:_ L40T-;L-'t53—z06 Phone Number. Amount of Bond: 7. Persons within the State of Florida Designated'by Owner upon whom notice or other documents maybe served as provided by Section 713.13(1)(a)7., Florida Statutes. I S. In addition, Owner designates Phone Number. of - to receive a copy of the Lienor's Notice as provided in Section 713,13(1)(b), Florida Statutes. Phone number,, 9. Expiration Date of Notice of Commencement (The expiration is 1 year from date of recording unless a different date is specified) WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART I, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. State of The regoi instrument by who has produced identif z or' kIMr of Lar,sr,Px-- (Pdnt Name a 4 Provide S{gn0t6ry aTillelOffice) Countyof 4 nowledgad before me this day of Q £i- of identification produced: Public,-Stat,State,of FlordadoskiionGG14673112022 Who is personally known to me 0 OR .0 k 0 mini This combination qualifies fora Federal EnergyEfficiencyTaxCreditwhenplacedinservice between Feb 17, 2009 and Dec 31, 2016. Product Ratin AHRI Certified Reference Number: 9155626 Date: 10/13/2017 Product: Split System: Heat Pump with Remote Outdoor Unit -Air -Source Outdoor Unit Model Number: 25HBC548A*030* Indoor Unit Model Number: FX4D,N(B,F)049L Manufacturer: CARRIER AIR CONDITIONING Trade/Brand name: CARRIER AIR CONDITIONING Series name: COMFORT15 HP Manufacturer responsible for the rating of this system combination is CARRIER AIR CONDITIONING Rat'ed.as follows in accordance with AHRI Stdirlard 210/240-20D8 for Unitary Air-Gond'itionHeat;Pump Equipment'a,nd 'stabject to vI rification of rating accuracy by AHRI-sport"cored >ipartytesting; Heating Capacity(Btuh) @ 17 F: 29000 ing and,Air-Source ndependent, third Ratings followed by an asterisk (') indicate a voluntary rerate of previously published data, unless accompanied with a WAS, which indicates an involuntary rerate DISCLAIMER AHRI does not endorse the product(s) listed on this Certificate and makes no representations, warranties or guarantees as to, and assumes no responsibility for, the product(s) listed on this Certificate. AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance ofthe product(s), or the unauthorized alteration of data listed on this Certificate. Certified ratings are valid only for models and configurations listed in the directory at www.ahri(lirectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI. This Certificate shall only be used for individual, personal and confidential reference purposes. The contents of this Certificate may not, in whole or in part, be reproduced; copied; disseminated; a-1 entered into a computer database; or otherwise utilized, in any form or manner or by any means, except for the user's individual, personal and confidential reference. AIR-CONDITIONING, HEATING, CERTIFICATE VERIFICATION & REFRIGERATION INSTITUTE The information for the model cited on this certificate can be verified at www.ahridirectory.org, click on "Verify Certificate" link k . lif- honer'" and enter the AHRI Certified Reference Number and the date on which the certificate was issued, which is listed above, and the Certificate No., which Is listed at bottom right. ' 1315241568969946742014Air -Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: Building & Fire Prevention Division Residential Permit Card PERMIT NO. / 7 %3 O {/t ISSUE DATE: O CONTRACTOR: JOB ADDRESS: TYPE OF WORK: Post this permit in a conspicuous location outside Approved plans must be posted with permit for inspection Leave all work uncovered until inspected and approved Permit expires 6 months from date of issue or last approved inspection PROTECT FROM WEATHER BUILDING INSPECTION TYPE APPROVED REECTED INSPECTOR ELECTRICAL INSPECTION TYPE APPROVED REJECTED INSPECTOR FOOTER INSPECTION ELECTRIC UNDERGROUND STEMWALL FOOTER/SLAB STEEL BOND FORMBOARD SURVEY T.U.G. / PRE POWER SLAB / MONO -SLAB ELECTRIC ROUGH LINTEL / TIE BEAM ELECTRIC FINAL SHEATHING - ROOF MECHANICAL INSPECTION TYPE APPROVED REJECTED INSPECTORSHEATHING - WALLS FRAME MECHANICAL ROUGH INSULATION ROUGH IN MECHANICAL FINAL DRYWALL/SHEETROCK PLUMBING INSPECTION 77PE APPROVED REJECTED INSPECTORLATHINSPECTION FINAL STUCCO/SIDING UNDERGROUND ROUGH FIREWALL SCREW TUB SET FIREWALL FINAL SEWER INSULATION FINAL PLUMBING FINAL FINAL SFR GAS INSPECTIONS INSPECTION 77PF. APPROVED REJECTED INSPECTORROOF INSPECTION TYPE APPROVED REJECTED INSPECTOR GAS UNDERGROUND PIPE ROOF DRY-fN GAS ROUGH -IN FINAL ROOF GAS FINAL MISCELLANEOUS / FINAL INSPECTIONS INSPECTION 7TPE APPROVED REJECTED INSPECTOR INSPECTION 77PE APPROVED REJECTED INSPECTOR FINAL DEMO FINAL DOOR FINAL SOLAR PANELS FINAL WINDOW FINAL POOL SCREEN FINAL SCREEN ROOM FINAL UTILITY BUILDING FINAL BUILDING OTHER MOBILE HOME TIE -DOWN MOBILE HOME FINAL WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE: IN ADDITION TO THE REQUIREMENTS OF THIS PERMIT, THERE MAY BE ADDITIONAL RESTRICTIONS APPLICABLE TO THIS PROPERTY THAT MAY BE FOUND IN THE PUBLIC RECORDS OF THIS COUNTY, AND THERE MAY BE ADDITIONAL PERMITS REQUIRED FROM OTHER GOVERNMENTAL ENTITIES SUCH AS WATER MANAGEMENT DISTRICTS, STATE AGENCIES OR FEDERAL AGENCIES FBC 105.3.3 REVISED: 4-17 Inspection Line: 407.792.6069 or 855.541.2112 TO SCHEDULE AN INSPECTION: Dial 407.792.6069 or 855.541.2112 Provide the items requested during the message The type of inspection requested must be scheduled under the appropriate permit type Follow the prompts To Schedule Fire Inspections: Please call 407.562.2786 *** PLEASE NOTE: Inspections scheduled by 5:00 p.m. will be conducted the next business day. If you experience difficulty, please call 407.688.5150 Monday - Thursday 7:30 am - 5:30 pm for assistance. AUTOMATED INSPECTION SYSTEM CODES BUILDING ELECTRICAL FOOTER 104 ELECTRIC UNDERGROUND 211 STEM WALL 102 FOOTER / SLAB STEEL BOND 221 FORMBOARD SURVEY 147 T.U.G. 216 SLAB / MONO -SLAB 103 PRE POWER FINAL 218 LINTEL / TIE BEAM 105 ELECTRIC ROUGH 212 SHEATHING - ROOF 106 ELECTRIC FINAL 213 MECHANICALSHEATHING - WALLS 115 FRAME 109 MECHANICAL ROUGH 409 INSULATION ROUGH -IN 110 MECHANICAL FINAL 410 PLUMBINGDRYWALL / SHEETROCK 131 LATH INSPECTION 132 UNDERGROUND ROUGH 322 FINAL STUCCO / SIDING 130 TUB SET 312 FIREWALL SCREW 120 SEWER 311 FIREWALL FINAL 143 PLUMBING FINAL 313 GASINSULATIONFINAL113 FINAL SFR 138 GAS PIPING UNDERGROUND GAS ROUGH -IN 328 314OOF ROOF DRY -INF 116 GAS FINAL 315 INAL ROOF III FINAL DEMO FINAL SOLAR PANELS FINAL POOL SCREEN FINAL UTILITY BUILDING MOBILE HOME TIE -DOWN Miscellaneous Notes: MISCELLANEOUS / FINAL INSPECTIONS 126 FINAL DOOR 136 134 FINAL WINDOW 137 139 FINAL SCREEN STRUCTURE 127 124 FINAL BUILDING - OTHER 112 145 MOBILE HOME BUILDING FINAL 146 REVISED: 4-17 Inspection Line: 407.792.6069 or 855.541.2112 FIRE INSPECTIONS CITY OF SANFORD 407.562.2786 BUILDING & FIRE PREVENTION BUILDING INSPECTIONS 300 N PARK AVE 855.541.2112 SANFORD FL 32771 DRIVEWAYS -SIDEWALK 407.688.5080 Page 2 Application Number . . . . . 17-00003024 Date 2/05/18 Property Address . . . . . . 142 WILSON BAY CT Parcel Number . . 22.19.30.503-0000-2540 Application description . . . MECHANICAL PERMIT Subdivision Name . . . . . . Property Zoning . . . . . . . PUD Permit . . . . . . MECHANICAL PERMIT -RESIDENTIAL Additional desc . . Phone Access Code 1007137 Permit pin number 1007137 Required Inspections Phone Insp Seq Insp# Code Description Initials Date 1000 410 MH02 MECHANICAL FINAL _/_/_