122 Long Leaf Pine Cir - BR17-002709 - GARAGE DOORCITY OF SANFORD 1ECEiv BUILDING & FIRE PREVENTION PERMIT APPLICATION No: SEP 13 209 Application Vy. Documented Construction Value: $ 1555.85 Job Address: 122 LONG LEAF PINE CIRCLE Historic District: Yes No 0 Parcel ID: 11-20-30-509-0000-0120 Residential X Commercial Type of Work: New Addition Alteration Repair 0 Demo Change of Use Move Description of Work: REPLACE EXISTING GARAGE DOOR SIZE FOR SIZE Plan Review Contact Person: CHARLES MERINO Title: INSTALL MANAGER Phone: 3212848290 Fax: 8772250658 Email: CMERINO@PRECISIONDOOR.NET Property Owner Information Name GUILLEN, ANTHONY Phone: 713-302-4711 Street: 122 LONG LEAF PINE CIRCLE Resident of property? YES City, State Zip: SANFORD, FL 32773 Contractor Information Name WILLIAM WALDEN Phone: 321-284-8290 Street: 244 OBRIEN RD Fax: 877-225-0658 City, State Zip: FERN PARK FL 32730 State License No.: CRC1330671 Architect/Engineer Information Name: Phone: Street: Fax: City, St, Zip: E-mail: Bonding Company: Mortgage Lender: Address: Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY. BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a. permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. FBC 1.05.3 Shall be inscribed with the date of application and the code in effect as of that date: 51h Edition (2014) Florida Building Code Revised: June 30, 2015 Permit Application NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property ofthe requirements ofFlorida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal. The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value, credit will be applied to your permit fees when the permit is issued. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. 13 -17 Agent Date I w Date oa"y'' CHARLES E. MERINO MY COMMISSION # FF940114 EXPIRES December 01, 2019 Owner""' tis;s I'i ,qRA; % to e or Produced ID yqEn Type o tV 1 tj.)WC0 b 09/13/17 Signature ofContractor/Agent Date WILLIAM WALDE Pri actor/A nt's 13/17 e fNotary- t ofFlorida P CHARLES MY COMMISSION EXPIRES Date E. MERINO FF940114 December 01, 2019 Contractor/Agent is X Personally Known to Me or Produced lD Type of ID BELOW IS FOR OFFICE USE ONLY Permits Required: Building Electrical Mechanical Plumbing[] Gas[] Roof Construction Type: Occupancy Use: _ Flood Zone: _ Total Sq Ft of Bldg: Min. Occupancy Load: New Construction: Electric - # of Amps Fire Sprinkler Permit: Yes No # of Heads APPROVALS: ZONING: ENGINEERING: COMMENTS: UTILITIES: of Stories: Plumbing - # of Fixtures Fire Alarm Permit: Yes No WASTE WATER: BUILDING: '5r !?:ZO- 17 Revised: June 30, 2015 Pennit Application 9/13/2017 SCPA Parcel View: 11-20-30-509-0000-0120 WA iCd.W1lG ilJi l Parcel Information Property Record Card Parcel: 11-20-30-509-0000-0120 Owner: GUILLEN ANTHONY Property Address: 122 LONG LEAF PINE CIR SANFORD, FL 32773 Parcel 11-20-30-509-0000-0120 Owner Property Address GUILLEN ANTHONY _ f 122 LONG LEAF PINE CIR SANFORD, FL 32773 Mailing Subdivision Name 122 LONG LEAF PINE CIR SANFORD, FL 32773 HIDDEN LAKE VILLAS PH 4 I Tax District S1-SANFORD DOR Use Code 0103-TOWNHOME Exemptions 00-HOMESTEAD(2016) n Legal Description LOT 12 HIDDEN LAKE VILLAS PH 4 PB 28 PGS 26 TO 28 Taxes Value Summary 2017 Working 2016 Certified Values Values Valuation Method Cost/Market I Cost/Market Number of Buildings 1 1 Depreciated Bldg Value 79,845 I........................._........_..... 68,297 Depreciated EXFT Value Land Value (Market) 20,000 16,000 Land Value Ag Just/Market Value " 99,845 84,297 Portability Adj Save Our Homes Adj 13,778 0 Amendment 1 Adj P&G Adj 0 0 Assessed Value 86,067 84,297 Tax Amount without SOH: $876.43 2016 Tax Bill Amount $876.43 Tax Estimator Save Our Homes Savings: $0.00 II TRIM Notice Helo Does NOT INCLUDE Non Ad Valorem Assessments Taxing Authority --Assessment Value Exempt Values Taxable Value County General Fund $86,067 M----_._.— -.- -i 50,000 36,067 Schools $86,067 25,000 61,067 City Sanford $86,067 50,000 36,067 SJWM(Saint Johns Water Management) i $86,067 50,000 36,067 County Bonds $86,067 50,000 36,067 Sales Description j Date i Book Page Amount Qualified Vac/Imp WARRANTY DEED 10/1/2014 08367 0017 0233 89,900 Yes Improved WARRANTY DEED 4/1/2014 3 08244 50,000 No Improved QUIT CLAIM DEED j._ ..... 7/1/2011 i 07957 0376 100 No Improved WARRANTY DEED 8/1/2002 44 5 0242 784, 00 Yes Improvedrovedp WARRANTY DEED 12/1/2001 04288 Y 10209 65,000 Yes Improved SPECIAL WARRANTY DEED 7/1/2000 03939 1494 52,800 No Improved SPECIAL WARRANTY DEED 6/1/2000 No Improved CERTIFICATE OF TITLE a_03871 6/1/2000 0836...__.__._........._...............__......_.._...$100 03862 0726 $100 No Improved PROBATE RECORDS 8/1/1999 03708 1 2028 100 No Improved WARRANTY DEED 9/1/1984 01582 j 105& 52,500 Yes Improved Find Comparable Sales Land http://parceldetai1.scpafl.org/Parcel DetailInfo.aspx?PI D=11203050900000120 1 /2 Altamonte Springs, Casselberry, Lake Mary, Longwood, Sanford, Seminole County, Winter Springs Date: 09-13-17 I hereby name and appoint: Thomas an agent of: Precision Door Service Name of Company) to be my lawful attorney -in -fact to act for me to apply for, receipt for, sign for and do all things necessary to this appointment for (check only one option): The specific permit and application for work located at: 122 LONG LEAF PINE CIR SANFORD, FL 32773 Street Address) Expiration Date for This Limited Power of Attorney: N/A License Holder Name: William Walden State License Number: CRC1330671 - Signature of License Holder:, STATE OF FLORIDA COUNTY OF Seminole The foregoing instrument was acknowledged before me this 13 day of SEPTEMB€R 20017 , by William Walden who is r Kpersonally known to me or who has produced as identification and who did (did not) take an oath. i Notary Seal) Print or type name Notary Public - State of _ Commission No. My Commission Expires; Rev. 08.12) Florida m n n m z 3 UPm D N N CD i m m . n Otoa O 0 CITY OF Building & Fire Prevention DivisionSkNvuDOORS / WINDOWS PERMIT GUIDELINES FIRE DEPARTMENT All permit application packages must be complete prior to acceptance. You must check each box to the left or indicate n/a on this submittal. A complete application package shall include the following: All permit applications must be complete prior to acceptance. A complete application shall include the following: Building Permit Application completed, signed and notarized. Application must include correct address and complete parcel I.D. number. Copy of a contract, signed by the contractor and the property owner, indicating the documented construction value Copy of applicable contractor's license issued by the State of Florida (if the contractor is the applicant). A site specific notarized power of attorney shall be required from the licensed contractor if he/she appoints an employee of his/her company to sign the permit application as the contractor. Certificate of insurance indicating worker's compensation insurance coverage and naming the City of n Sanford as certificate holder, or a copy of a worker's compensation exemption issued by the State of b ' Florida (must be submitted with each application if contractor is the applicant). f7 J tcc- Owner Builder Statement / Affidavit (if the owner is the applicant). Must be signed in person at the Building Department) CCU Two (2) copies of an exterior wall floor plan indicating size, type and location of windows/doors.. C Completed and signed Statewide Product Approval Specification Form. 01 Two (2) copies of the manufacturer's installation instructions. These guidelines were compiled to assist the applicant in preparing a windows / doors permit application and may not be complete. The applicant is required to meet all City ofSanford, state, andfederal code requirements. Effective: August 1, 2017 9/13/2017 parceldetail.scpafl.org/FootprintPage.aspx?PID=11203050900000120&BLDGNO=1 &PAGENO=1 RECORD COPY Parcel: 11-20-30-509-0000-0120 Building No.: 1 Page No: 1 xx REVIEWED FOR CODE COMPLIANCE 5F PLA S EXAMINERI.10- DATE SANFORD BUILDING DIVISION 1 7 2 7 A 9 A PERMIT ISSUED SHALL BE CONSTRUED TO BE A vP-D//vc LICENSE TO PROCEED WITH THE WORK AND NOT AS AUTHORITY TO VIOLATE, CANCEL, ALTER OR SET ASIDE ANY OF THE PROVISIONS OF THE TECHNICAL SAN FORD CODES, NOR SHALL ISSUANCE OF A PERMIT PREVENT pFpgRTHEBUILDINGOFFICIALFROMTHEREAFTER 6REQUIRINGACORRECTIONOFERRORSINPLANS, CONSTRUCTION OR VIOLATIONS OF THIS CODE http://parceldetaii.scpafl.org/FootprintPage.aspx?PID=11203050900000120&BLDGNO=1 &PAGENO=1 1/1 r City of Sanford Building and Fire Prevention Product Approval Specification Form Permit # Project Location Address 122 LONG LEAF PINE CIRCLE As required by Florida Statute 553.842 and Florida Administrative Code 9N-3, please provide the information and product approval number(s) on the building components listed below if they are to be utilized on the construction project for which you are applying for a building permit. We recommend that you contact your local product supplier should you not know the product approval number for any of the applicable listed products. Be aware that windows, skylights, and exterior doors must be tested in accordance with the Florida Building Code, Section 1714.5. More information about Statewide Product Approval can be obtained at www.floridabuildinq.org. The following information must be available on the jobsite for inspections: 1. This entire product approval form 2. A copy of the manufacturer's installation details and requirements for each product. Category/ Subcategory Manufacturer Product Description Florida Approval # include decimal 1. Exterior Doors Swinging Sliding Sectional AMARR HERITAGE 1000 8X7 FL5302.5-R7 Roll U Automatic Other - OVERHEAD 2. Windows Single Hun Horizontal Slider Casement Double Hun Fixed Awning Pass Through Projected Mullions Wind Breaker Dual Action Other June 2014 Category/Subcategory Manufacturer Product Description(including Florida Approval # decimal 3. Panel Walls Siding Soffits Storefronts Curtain Walls Wall Louver Glass block Membrane Greenhouse E.P.S Composite Panels Other 4. Roofing Products Asphalt Shingles Underla ments Roofing Fasteners Nonstructural Metal Roofing Wood Shakes and Shingles Roofing tiles Roofing Insulation Waterproofing Built up roofing System Modified Bitumen Single Ply Roof Systems Roofing slate Cements/ Adhesives / Coating Liquid Applied Roofing Systems Roof Tile adhesive Spray Applied Polyurethane Roofing E.P.S. Roof Panels Roof Vents Other June 2014 Category/ Subcategory Manufacturer Product Description Florida Approval # include decimal 5. Shutters Accordion Bahama Colonial Roll u Equipment Other 6. Skylights Skylights Other 7. Structural Components Wood Connectors / Anchors Truss Plates Engineered Lumber Railing Coolers/Freezers Concrete Admixtures Precast Lintels Insulation Forms Plastics Deck / Roof Wall Prefab Sheds Other 8. New Exterior Envelope Products Applicant's Signature Applicant's Name Please Print) June 2014 3 16 GA GAILY. RESIDENTIAL r 20" STRUTS ATTACHED V/ l1/4• 3/4' TIPROLLERDRAGNET1DSCREWSAT HENHEADATTACHVICE, U4' x 3/4' HEX HEAD SCREWS ER CETITIRSTILE PER BRACKET GArT, USTAELEROLLER CARRIER ACHED V/ (2) 1/4' x U2' DOLT 6 NUT PER BRACKET TYPICAL TOP FIXTURES t N. T.S. 1 gx O 0 0 r 20GA STRUTS ATTACHED LS L eKTM OA6OO 6H551I) W/ ( 2) U4' x 3/4' O 24 W SKD1 (N050) HEX HEAD SCREWS AT 14GA DUNASAFE CENTERSTILECENTERIONOLATTACHED V/ C4) UI- x 3/4- HEX HEAD SCREWS LE Vx AT THIS LOCATRON SE ( 4) TO JAMS TRACK SPLICE BOLTS 1 NUTS SEGUEOJAMBMAC (S SPLICE DLL. x 1N3TS' LAG BOLTS e S TYPICAL DURASAFE CENTER HINGE/ , (SPLICE) SEE ( TABLE 2) ON PAGE 3 FOR N.T.S. L (1) 5/15' DIA x 1-5/r OMMENDED SECTION CONFIGURATION S LAG BOLT ATTACHED TO JAMB AT EA JAMB BRACKET A ,$ EPAGE 2 ION OPTIONAL / OLAZEEn SECTIONSUSTRUT ARIDSTILELAYOUT14GADURASAFE12GA GALV. STEEL EMBOSSMENTS 41T SHOWN 3 FOR CLARITY6SEE TABLE 4 ON PAGE 3 1 A FOR STILE PLACEMENTS 9'-O' MAX INSIDE ELEVATION N.T. S. 2' 20GY STRUT ATTACHED V/ (2) 114' x 3/4' STILE STIFFENERS ( D LOCATED IN RINGS HOL HEX HEAD SCREWS AT OI TOP SECTION ONLY CENTER STILE HOLES FOR STRUT ATTACHMENT STRUT NOT SEWN y. FOR CLMTTY) O O 1AO8DOLT ATTACHED TO JAMS (NO. 2 OR BETTER) AT EA JAMB BRACCET OPTIONAL STEP ZO GAMOLDING RD GA. GKV STEEL BGLT AND NUT Y GAIN. STEEL IRA RIVETS TRACK THICKNESS TRACK MOUNTING DETAIL N.T. S. THROUGH VENTS PROVIDE 70. N 62 w k FOR OPTIU VENT) OFU(OBSTRUC' AIR FLOVEACH. r 7 IALL ROLLER V/ 5' TYPICAL BOTTOM BRACKET 4 N.T. ENDHIAM ATTACHED THROUGH) JAM9 BRACKETS V/ C2) U4' x 3/Y G ATTACHED W/ (1) 1/4'-20 STRUTS HEX HEAD SCREWS END H87(FiE TRACK SPLICE BOLT a NUT ATTACHED V/ 2) - . 14 Gil OR (2) RIVETS U4' x 3/4• HEX 14GA DLRASAFERE HEAD SCVSROLLERCARRIERSATTACHEDBTOENDSTILEV/ (2h 1/4' x 3/4• HEX HEAD SCREWS PER CARRIER G r 7 BALL STEEL A ROLLER V/ 5' STEM 21 x 20 GA STRUTS _ 1) PER SECTION SEE (TABLE 3) ON PAGE 3 TYPICAL DURASAFE END HINGE / 3JANa BRACKET SPACD N.T.S.XIFl N.T. TRA(DC (%GURA710N FOR 8'8• UP TO 14' TALL DOORS N.T. S. cO4ri s" x SECTIONA — A (SIDE VIEWI N.LS iEACI ARiYJJ. JMNS MDEnO NAEIIIM OSOI LOADS 0" D UIXIFT t t0R.7 L S Dam AND NHwME TAL SE DEROMm, WMlFACRRD AND NSTAUmxrlNSTANIA=I As mFanN BY DASILI AL0 ALLE b oA IIx GOD) AOUFO FORMED LKHT S. SUPPORTING S1RICM EJ1EIRS GIRL E D[DOED n A EASM PAOT65eNK BOOM FOR OD LOADS WXCAIED ON THIS DURNW N AIOTbI 70 OTHER LOAOIIE THE METHOD OF TESTING WAS IN SUBSTANTIAL .- CONFORMANCE WITH THE PROCEDURE DESCRIBED IN ASTM E330 AND ANSI/DASMA 108. THE PRESSURES SHOWN ON THE DRAWINGS WERE CALCULATED USING ASCE 7-10 WITH THE FOLLOWING PARAMETERS ( 5 FEET OF DOOR WIDTH IN THE END ZONE, ROOF AT ANY SLOPE . WIND SPEED MPH 142 129 122 117 112 EXPOSURE LEVEL B C C D D MEAN ROOF HEIGHT 30' 15' 25' 15 1 25 INTERIOR OF WAGE IWC DDTN 1M 0®Wi WDS .sAo LJRs TeX NHOME2 3 ta.TMF, 5302. 5-R% 2 ry P•"--- r 1 - . E MAX SIZE 9' 14' zQ O • . y( J` t• N Y,fS/9DESIGN LOADSif PSF- 22.6 PSF I+19. 1 TATE OF PB7 iFi4, Og1Qp'\c v 33. 9 PSF P FL i,s/OfyA4EOt a W CARRIAGE COURT WD(STO YODEL #850 OAK SIIIDYI YODEL #600 STRATFORD YODEL /95O HERITAGE T Short, long, Rush & 0 DE GIAEI BY OU DAII 06/H/65 B ORCHID BT ME DAg 61/14J1a1 B B 2' 20GA. STRUT LOCATED AT THE TOP OF GLAZED SECTION ATTACHED W/(2) 1/4' X 3/4' HEX HEAD SCREWS AT END AND CENTER STILE PTIONAL SHORT PANEL GLAZED SECTION STRUT AND STILE LAYOUT B B 2' 2OGA STRUT LOCATED AT THE TOP OF GLAZED SECTION ATTACHED W/(2) 1/4' X 3/4' HEX HEAD SCREWS AT END AND CENTER STILE OPTIIINAL LONG PANEL GLAZED SECTION STRUT AND STILE LAYOUT 10- SHORT PANEL GLAZING FASTENER DETAIL N.T.S. 10- LONG PANEL GLAZING FASTENER DETAIL N.T.S. GAZING OPTION CROSS SECTION GLAZING NOT AVAILABLE IN WIND-BORNE DEBRIS REGION GLAZING MEETS ASTM E1300-04 Frame WINDOW FRAME OPTIONAL Decra INSERTSUVPROTECTION // z WTH UV PROTECTION MIN. 3/32- THICK SSB GLASS AT 10 910RY PANEL B WFRRA/ 1E AT EACH LONGPANEL YONO4' PAN MEADM FRAME MOLDED INSIDE FIR SECTION B-B WOOD JAMB ATTACHMENT TO STRUCTURE 5/16' X 3' LAG SCREWS STARTING 6' FROM ENDS THEN 24' aC. Cl 1/2' EMBEDMENT) HILTI KVIK BOLT 3/(' X 4' STARTING 6' FR31 ENDS I 24. O.C. a 1/2' EKBEDMENT) HILTI SLEEVE ANCHOR 3/8' X 2-3/4' STARTING 6' FROM ENDS THEN 24' ILC. Q 1/4' EMBEWEITT) TFW/RAMSET REDHEAD RRU-HILT) 3/8' X 4' STARTING 6' FR13M ENDS THEN 24' O.C. 2 I/r EMBEDMENT) SIMPSON 1/4' X 3' TIT EN SCREWS STARTING 6' FROM ENDS, USE PAIRS OF FASTENERS 3' APART) AT 24, OC. (1 1/2' EMBEDMENT) HILTI 1/4' X 2-3/4, KVII(-CON 114 SCREWS STARTING 6' FROM ENDS, USE PAIRS OF FASTENERS Cr APART) AT 24' O.C. a 1/4' EMBEDMENT) HILT] SLEEVE ANCIQt 3/8' % 2-3/L' STARTING 6• FROM ENDS THEN 24' O.C. 1 1/4' EMBEDMENT) aBt USE FASTENERS FOR HOLLOW C-90 BLOCTO 4AGS AND BELTS CAN BE COUNTERSUNK TO PROVIDE A FLUSH MOUNTING SURFACE PREPARATION OF VOOD JAM BY OTHERSWOODI - F2X6 SC RUCiI.RE STRUCTURE GROUTED HL STRUCTURE I 2-3/4' ION t-L2' MIN 4' 1JAMB 3- MDN 1114 FBC 2010 LN MAX SIZE 5 4p: • NO E9' 14' DESIGN LOADSe*BII 19.1 PSF Q =i x 22. 6 PSF S E CIF E 2 CA PSF 33. 9 PSFi 01V :L C3 CAAmarr eA e ass CARRV 9 CnRT VwsTO 34L M, KC. 87M MODEL J550 OAK SUMMIT w/DuraSafe A MODEL #500 STRATFORD w/Dora3ate MODEL # 950 BERiTAGE w/DaraSafe T L-Lid L___I.1dI Short, Lent'. Flush III oat Summit Panel's AVAILABLE TRAP( CONFIGURATIONS Sa MM BY OJ DAIE OM4,V Mm Ilm N. T.S. B IRC-6009-IID-11 M8BYAgDAN "10 STET I OF 3 1. TABLE 1 TABLE 2 TABLE 3 TABLE 4 RfY ff31 101 ff DALE BY A U MM) WINN RAW tFO@ UX OB/ID/DT aJ A® Wama me am TM B If9.AIED 601E 6 00 au c uMTD TD W 7- 0 / Fac 2aD n 1 CM 0 0A 0 SIRR RMi1M FatV YClal 01 3 Rf MAX 14 00494 _ DESIGN LOADSe' e 19.1 PSF 22.6 PSF L9: ST OF TEST LOADS i O" 'c(0 R I DP,: k/ uss cNnt.¢ mixr VINSTOFfK[M. "c enoD MODEL /550 OAK SUMMIT w/Dara3afe MODEL #600 S UTFORD w/DuraSafe MODEL #950 HERYUGE w/Dura3afe Short, Long, Flush k Oak Summit Panel's 9ff DRAM BY DU DATE MA410 Wj= OW 8 =0 er AM DAk m/Npa IRC-6009-110-11 ALL TRACK ATTACHMENT SPACING i/-2' ALCOVED VITH SYP Qt SPf NO. 2 DR BETTER - WIT I ff 3 STRUT SPACING (BASED ON RECOMMENDED SECTION DOOR CONFIGURATION) TOP HEIGHT A B C D E F G T 6' 6" 18 1/4" 36 1/4" 54 1/4" 67 1/2" 7' 18 1/4" 39 1/4" 60 1/4" 73 1/2" 7' 6" 15 1/4" 33 1/4" 51 1/4" 69 1/4" 81" 8' 18 1/4" 36 1/4" 54 1/4" 72 1/4" 85 1/2" 8' 6" 18 1/4" 39 1/4" 60 114" 78 1/4" 91 1/2" 9' 151/4" 331/4" 51 1/4" 691/4" 871/4" 99" 9' 6" 18 1/4" 36 1/4" 54 1/4" 72 1/4" 90 1/4" 103 1/2" 10' 18 1!4" 39 1/4" 60 1/4" 78 1/4" 96 1/4" 109 1/2" 10'6" 18 1/4" 39 1/4" 60.1/4" 81 1/4" 102 1/4" 115 1!2" 11' 18 1/4" 36 1/4" 54 1/4" 72 1/4" 90 1l4" 108 1/4" 121 1/2" 11' 6" 18 1/4" 39 1/4" 60 1 /4" 78 1/4" 96 1/4" 114 1/4" 127 1/2" 12' 18 1/4" 39 1/4" 60 1/4" 81 1/4" 102 1/4" 1201/4" 1331/2" 2'6" 18 1/4" 36 1/4" 54 1/4" 72 1/4" 90 1/4" 108 1/4" 126 1/4" 139 1/2" 13' 18 1/4" 39 1/4" 60 1/4" 78 1/4" 961/4" 1141/4" 132 1/4" 1451/2" 13° 6" 18 1/4" 39 1/4" 60 1/4" 81 1/4" 102 1/4" 120 1/4" 138.1l4" 151 1/2" 14' 181/4" 391/4" 601/4" 81 1/4" 102 1/4" 1231/4" 1441/4" 1571/2" DOOR HEIGHT TRACK ATTACHMENT SPLICE A B C D E F G S 6' 6" 10" 38" 58" 70" 7' 10" 38" 58" 76" 7' 6" 4" 28" 52" 76" 82" 8' 10" 34" 58" 82" 88" 8' 6" 4" 28" 52" 76" 94" 9' 10" 34" 58" 82" 100" 9' 6" 4" 28" 52" 76" 100" 106" 10' 10" 34" 58" 82" 106" 112" 10' 6" 4" 28" 52" 76" 100" 118" 11' 10" 34" 58" 82" 106" 124" 11' 6" 4" 28" 52" 76" 100" 124" 130" 12' 10" 34" 58" 82" 106" 130" 136" 12' 6" 4" 28" 52" 76" 100" 124" 142" 13' 10" 34" 58" 82" 106" 130" 148" 13' 6" 4" 28" 52" 76" 100" 124" 148" 154" 14' 10" 34" 58" 82" 106" 130" 154" 160" DOOR HEIGHT SECTION HEIGHTS Btm 2 3 4 5 6 7 8 14' 0" 21" 21" 21". 21" 21" 21" 21" 21" 13' 6" 21" 21" 21" 21" 21" 18" 18" 21" 13' 0" 21" 21" 21" 18" 18" 18" 18" 21" 12' 6" 21" 18" 18" 18" 18" 18" 18" 21" 12' 0" 21" 21" 21" 21" 21" 18" 21" 11' 6" 21" 21" 21" 18" 18" 18" 21" 11' 0" 21" 18" 18" 18" 18" 18" 21" 7 10' 6" 21" 21" 21" 21" 21" 21" 10' 0" 21" 21" 21" 18" 18" 21" 9' 6" 21" 18" 18" 18" 18" 21" 9' 0" 18" 18" 18" 18" 18" 18" 8' 6" 21" 21" 21" 18" 21" 8' 0" 7' 6" T 0" 21" 18" 21" 18" 18" 21" 18" 18" 21" 18" 18" 21" 21" 18" i----------jjj 6' 6" 21" 18" 18" 21" Section Width ft) Panel Type Center Stile Location Measured from Left Edge) Max Design Loads Allowed Positive PSF) Negitile PSF) 8' 0 Short, Oak Summit 48.000 21.4 25.3 8' 0 Lang 48.000 21.4 25.3 8' 2 Short, Oak Summit 49.000 20.9 24.8 8" 2 Long 49.000 20.9 24.8 8` 4 Short, Oak Summit 50.000 20.5 24.3 8' 4 Long 50.000 20.5 24.3 8' 6 Short, Oak Summit 51.000 20.1 23.8 8' j6 Long 51.000 20.1 23.8 8' j8 Short, Oak Summit 52.000 19.7 23.4 8' j 8 Long 52.000 19.7 23.4 8', 10 Short, Oak Summit 53.000 19.4 22.9 8'! 10 Long 53.000 19.4 22.9 9' 0 Short, Oak. Summit 54.000 19.1 22.6 9', 0 Long 54.000 19.1 22.6 REQUIRED INSPECTION SEQUENCE BP# 1-7 , ,7 7fyq Address: BUILIDING (PERMIT Min Max .. Inspection Description Footer / Setback Stemwall Foundation / Form Board Survey Slab / Mono Slab Prepour Lintel / Tie Beam / Fill / Down Cell Sheathing — Walls Sheathing — Roof Roof Dry In Frame Insulation Rough In Firewall Screw Pattern Drywall / Sheetrock Lath Inspection Final Solar Final Firewall Final Roof Final Stucco / Siding Insulation Final Final Utility Building p Final Door Final Window Final Screen Room Final Pool Screen Enclosure Final Single Family Residence Final Building (Other) ELECTRICAL PERMIT Min Max I[ns ection IIDescrn tion Electric Underground Footer / Slab Steel Bond Electric Rough T.U.G. Pre -Power Final Electric Final r J; . 4. ec Y. , t. .F.L T-1'S4a• t til/'TiiSrt'. Min Max Ins ection Descri tion Plumbing Underground Plumbing Sewer Plumbing Tub Set Plumbing Final 1V'JIP,CHANICAL. IPEJRMIT Min Max Ins ection IIDescri tion Mechanical Rough Mechanical Final II Min I Max I Inspection Description Gas Unde Gas Roug Gas Final REVISED: June 2014 Billing Address Anthony Guillen 122 Long Leaf Pine Circle Sanford, FL 32773 USA Precision Door Service of Central Florida Invoice 29436736 244 O'Brien Rd Invoice Date 9/13/2017 Fern Park, FL 32730 Completed Date 877-225-0658 Customer PO Description of Work Job Address Anthony Guillen 122 Long Leaf Pine Circle Sanford, FL 32773 USA Task # Description Quantity Your Price Your Total 1 City Permit sanford 1.00 125.00 125.00 2 12 inch Radius Track 1.00 0.00 0.00 3 8x7 Garage Door - Enduring Door Collection 1.00 8S6.00 856.00 4 Enduring 100 Non Insulated: Heavy-duty Exterior Steel - Durable, Reliable, Low 1.00 0.00 MOO Maintenance 5 Enduring Collection: 24 gauge steel 1.00 0.00 0.00 6 Lifetime Warranty on Hardware 1.00 0.00 0.00 7 Lifetime Warranty on Paint Finish 1.00 0.00 0.00 8 Short Panel Design 1.00 0.00 0.00 9 New Door Vinyl Trim Kit for Single Car Garage Door: Includes (1) Horizontal 1.00 S9.95 S9.9S piece and (2) Vertical pieces 10 1 SO off New Garage Door 1.00 150.00 1 SO.00 11 2x6 Pressure Treated Lumber Build out for 8-9' Garage Door: Includes Vertical 1.00 189,95 189.95 Jambs, Header and Spring Pad 12 PDS800 7' Belt Package 1.00 0.00 0.00 PDS Lifetime Warranty On Motor PDS Lifetime Warranty On Belt Rail PDS 5 Year Warranty On All Mechanical Parts PDS 1 Year Warranty On All Electrical Parts 13 7' Linear Belt Rail: PDS 1.00 0.00 0.00 14 PDS800 Belt Driven Garage Door Opener: Includes Belt rail, two remotes, 1.00 599.95 599.95 wireless keypad, wall control and safety sensors 15 75 off New PDS800 Garage Door Opener 1.00 75.00 75.00 16 Office Discount no keypad pad 1.00 50.00 50.00 Paid On Type Memo Amount 9/12/2017 Cash Deposit on door $140.00 9/15/2017 Check (ACH) 0607 $1,415.85 Sub -Total $1,555.85 Tax $0.00 Total Due $1,555.85 Payment $1,555.85 Balance Due $0.00 Contractor Number: CRC1330671