102 Splitlog Pl - BR18-004258 - SOLAR PANELSOCT 15 2018 CITY OF SANFORD BUILDING $ FIRE PREVENTION F D PERMIT APPLICATION Application No: Documented Construction Value: $ 21,785.40 Job Address: 102 SPLITLOG PL SANFORD, FL 32771 Historic District: Yes NoEl Parcel ID: 33-19-30-514-0000-0640 Residential 0 Commercial Type of Work: New Addition R Alteration Repair Demo Change of Use Move Description of Work: Installation of Photo Voltaic Solar Panels on Roof Plan Review Contact Person: Aimee McGurr Title: Permitting Coordinator Phone: 321-247-6073 Fax: Email: flpermits@momentumsolar.com Property Owner Information Name Razibul Islam Phone: 321-247-6073 Street: 102 SPLITLOG PL Resident of property? : Razibul Islam City, State Zip: SANFORD, FL 32771 Contractor Information Name Cameron Christensen / Momentum Solar Phone: 321-247-6073 Street: 8248 Parkline Blvd. Ste 100 Fax: City, State Zip: Orlando, FL 32809 State License No.: CVC57036 Arch itect/Eng1neer Information Name: Daniel Dunzik Phone: 908-872-3664 Street: 325 High St Fax: City, St, Zip: Metuchen, NJ 08840 E-mail: flpermits@momentumsolar.com Bonding Company: N/A Mortgage Lender: N/A Address: Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: 51 Edition (2014) Florida Building Code Revised: June 30, 2015 Permit Application NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. V Acceptance ofpermit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal. The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value, credit will be applied to your permit fees when the permit is issued. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. SignatureofOwner/Agent Date Razibul Islam Print Owner/Agent's Name Signature of Notary -State of orida DateArreeMcGurr NOTARY PUBLIC STATE OF FLORIDA Comm# GG200147 gV0E W%lb Expires 10/23/2021 Owner/Agent is Personally Known to Me or Produced ID > — Type of ID Q L- Signature o ontractor/Agent Date Cameron Christensen Printt-Contractor/Agent's Name Signature of Notary -State of Florida Date 61ARV4 Aimee MCGurr o! NOTARY PUBLIC STATE OF FLORIDA Comm# GG200147 acE t9 Expires 10/23/2021 Contractor/Agent is ;< Personally Known to Me or Produced ID Type of ID BELOW IS FOR OFFICE USE ONLY Permits Required: Building Electrical Mechanical Plumbing[] Gas[] Roof Construction Type: Occupancy Use: Total Sq Ft of Bldg: Min. Occupancy Load: New Construction: Electric - # of Amps Fire Sprinkler Permit: Yes No APPROVALS: ZONING: ENGINEERING: COMMENTS: Flood Zone: of Stories: Plumbing - # of Fixtures, of Heads Fire Alarm Permit: Yes No UTILITIES: WASTE WATER: FIRE: BUILDING: SC Revised: June 30, 2015 Permit Application 10/12/2018 SCPA Parcel View: 33-19-30-514-0000-0640 Pro ert Record Cardt7eatdJORnson,CFR Y Parcel: 33-19-30-514-0000-0640 j I Property Address: 102 SPLITLOG PL SANFORD, FL 32771F:ti t.x.tctxaa*r,tioamn p Y I. F j Parcel Information Parcel; 33-19-30-514-0000-0640 Owner(s) ISLAM, RAZIBUL - Tenancy by Entirety SHAMPA, SON ITA K -Tenancy by Entirety Property Address 102 SPLITLOG PL SANFORD, FL 32771 i Mailing 102 SPLITLOG PL SANFORD, FL 32771-7740 Subdivision Name COUNTRY CLUB PARK Tax District r................_..............__.................._.;._......-._..........-.........._......_......_..__....._._._...._......._......_._.. I S1-SANFORD DOR Use Code 01-SINGLE FAMILY Exemptions I 00-HOMESTEAD(2017) Ll Legal Description LOT 64 COUNTRY CLUB PARK PB 50 PGS 63 THRU 66 Taxes i Taxing Authority i County General FundI; 6 Schools I City Sanfordi SJWM(Saint Johns Water Management) County Bonds Sales Description j l WARRANTY DEED WARRANTY DEED WARRANTY DEEDj SPECIAL WARRANTY DEED s WARRANTY DEED_.._.._...___._._.._..._..__...._... o bid£ islit'A.}..it::'e g.Jrz Land Method Frontage LOT Building Information Value Summary Valuation Method Number of Buildings Depreciated Bldg Valuefi Depreciated EXFT Value ii Land Value (Market) Land Value Ag i j Just/Market Value'* j ! Portability Adji. 2019 Working Values — Cost/Market 1 156,872 213 38,000 195,085 2018 Certified Values Cost/Market 1 150,707 225 38,000 188,932 V, Save Our Homes Adj $11,907 $9,522 Amendment 1 Adj $0 $0 P&GiAdj $0 $0 ; y.. Assessed Value $183,178 $179,410 i i' W Tax Amount without SOH: $2,765.48 2018 Tax Bill Amount $2,586.76 Tax Estimator f V , Save Our Homes Savings: $178.72 i Does NOT INCLUDE Non Ad Valorem Assessments Assessment Value j Exempt Values i Taxable Value 183, 178 50,000 133,178 183, 178 25,000 158,178 183, 178 50,000 133,178 .' 183, 178 50.000 133,178 183, 178 50,000 133,178 i? Date j Book Page Amount j Qualified Vac/Imp 2/ 1/2016 08637 1971 229,000 Yes Improved 8/ 1/2015 08538 1200 118,000 Yes Improved 3/ 1/2014 08241 0775 100 No Improved 5/ 1/1999 03644 1234 122,400 Yes Improved 7/ 1/1996 03107 0113 44,000 No Vacant Depth j Units Units Price. ....._.__....._.. - - - - Land Value 38, 000 1 s hftp:// parceldetai1.scpafl.org/ParcelDetailInfo.aspx?PlD=33193051400000640 1/2 DocuSign Envelope ID: 363B084C-EF91-4502-8F2F-D9B71AA4A036 L 18-FL-0049343 SOLAR LOAN AND SECURITY AGREEMENT e This Solar Loanand Security Agreement (this "Agreement"), dated October 10, 2018 (the "Effective Date"), is between Razibul Islam (individually and jointly referred to as "Borrower" or "you", whether one or more) and Dividend Solar Finance LLC L'ender," "we," or "us"). Borrower's home and installation address is 102 Splitlog Place, Sanford, FL 32771 (the "Home" ). Lender's address is 433 California St., Suite 300, San Francisco, CA 94104. Please read all pages of this Agreement carefully. Lender has agreed to make a loan to Borrower (the "Loan"), and Borrower agrees to pay back the Loan based on the terms of this Agreement. Borrower agrees that proceeds from the Loan will solely be used to pay for the design and installation of solar photovoltaic (PV) electricity generation equipment (the "Collateral") at the Home. Borrower is purchasing the Collateral from Momentum Solar ("Seller"). Borrower will have a separate agreement with the Seller or third -party contractor ("Contractor") to install the Collateral at the Borrower's Home. TRUTH IN LENDING ACT DISCLOSURES t ANNUAL FINANCE CHARGE Amount Financed, Sl Total of Payrticnt's_ PERCENTAGE RATE E The cost ofyour credit as a The dollar amount the credit The amount of credit provided Tlie amountyou will have paid yearly rate. will cost you. to you or on your behalf ,4t j,i,.; after you have'made all payme its as scheduled. h^ 5.99% 16,192.22 e r.,,,. $21,7$5.40 37 977.62 e Your Paten` Schedule W ll,Be :. Number ofPaymentsments Amount ofPayments i'<+'' When Payments Are Due T16 $10875(e) ;_ Monthly, beginning December 17, 2018(e) 224 f$1 G'1;78(e) `° Monthly, beginning April 17, 2020(e) Security: You are giving a security Iti0rest in the`Collateral bung purchased. Late Charge: If we do not,fd6erve a payment m full within 15 days of its due date, you will pay a late charge equal to the greater of 25 or three (3) percent ofthe unpaid amou f ofthe payment then due, provided that the late charge will not exceed $50. Prepayment You may prepay all or ny pbrtion ofthe Loan at any time without penalty. 4TermsYouShouldread<:the remainder,'of this "Agreement for additional information about security interests, nonpayment, defaults, prepayment refunds and.our right to require repayment in full before the scheduled maturity date. e): Denotes an estimate. i ITEMIZATION OF AMOUNT FINANCED 1. Princip "AV ount of Loan 1. Amounts Paid to Others on Your Behalf a. To Seller/Contractor for Collateral and Installation 2. Amount Financed 21,785.40 21,785.40 21,785.40 Principal Amount of Loan. The total amount of money that is being borrowed from Lender (the "Principal") is provided in the Amount Financed box above. The Principal amount is the sum of all the payments Lender is making on Borrower's behalf. By signing this contract, Borrower is directing Lender to make those payments based upon the Seller/Contractor meeting certain requirements related to the design and installation of the Collateral ("Milestones"), The first Milestone is the execution of a work order, which provides the details of the design and installation of the Collateral, and which is signed by the Seller/Contractor and Lender ("Work Order"). The second Milestone is the installation of the Collateral ("Substantial Completion"). Lender will disburse a portion of the Principal at the first Milestone and will disburse the remaining amount at the second Milestone, and the amount disbursed at each Milestone will be based upon arrangement between Seller/Contractor and Lender. Borrower agrees that Lender is not obligated to make any payment until it has received all documentation necessary or appropriate, as determined by Grant MaloY, Clerk Of The Circuit Court & Comptroller Seminole County, FLInst #2018118421 Book:9231 Page:1256; (1 PAGES) RCD: 10/15/2018 2:16:45 PM REC FEE $10.00 THIS INSTRUMENT PREPARED BY: Name: Aimee McGurn c/o Momentum Solar Address: 8248 ParKline Blvd, Ste 100 Orlando, FL 32809 NOTICE OF COMMENCEMENT Permit Number. Parcel ID Number: 33-19-30-514-0000-0640 The undersigned hereby gives notice that Improvement will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following information Is provided In this Notice of Commencement. 1. DESCRIPTION OF PROPERTY: (Legal description of the roperty and street address if available) Lot 64 Country Club Park PB50 Pgs 63 thru 6P6 102 SPLITLOG PL SANFORD, FL 32771 2. GENERAL DESCRIPTION OF IMPROVEMENT: Installation of photo voltaic solar panels on roof 3. OWNER INFORMATION OR LESSEE INFORMATION IF THE LESSEE CONTRACTED FOR THE IMPROVEMENT: Name and address: Razibul Islam 102 SPLITLOG PL SANFORD, FL 32771 Interest in property: Owner Fee Simple Title Holder (if other than owner listed above) Name: 4. CONTRACTOR: Name: Cameron Christensen / Momentum Solar Phone Number. 321-247-6073 Address: 8248 Parkline Blvd. Ste 100 Orlando, FL 32809 S. SURETY (if applicable, a copy of the payment bond Is attached): Name: N/A Amount of Bond: 6. LENDER: Name: N/A Phone Number. Address: 7. Persons within the State of Florida Designated by Owner upon whom notice or other documents maybe served as provided by Section 713.13(1)(a)7., Florida Statutes. Name: Phone Number. 6. In addition, Owner designates to receive a copy of the Lienot's Notice as provided in Section 713.13(1)(b), Florida Statutes. Phone number. 9. Expiration Date of Notice of Commencement (The expiration is 1 year from date of recording unless a different date Is specified) WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. Signature of Owner or Lessee, orOwner's or Lessee's Aurrorized 0r6cer/DlreetonPartner/Manager) Razibul Islam Owner Print Name and Provide Signatory's TiWOfli e) State of F— 10V-1 Cld Countyof 5 2-er iY\o'-C The foregoing Instrument was acknowledged before me this i day of , Q C, t- . , 20 I by Razibul Islam Who is personally known to me OR Name of person malting statement who has produced identification a type of Identification produced: p1--- pRy Aimee McGurr P NOTARY PUBLIC c SSTATE OF FLORIDA CERTIFFIED COPY GRAN TP.'i,f 0`d•, ? Comm# GG200147 OF THE OCCUI"i » i'<iit?' f' ` N4„ 9 Expires 10/23/2021 CL"" ANC C0 1r } f'Q' t R ENt: tan' CA- 17)<---- Notary Signaure s momentum SOLAR Contractor's Authorization Letter I Cameron Christensen license holder for Momentum Solar authorize the following people to apply/sign for permits under my license number CVC57036 Please allow ONLY the person(s) listed below to sign. This letter supersedes all others. Aurelie Joseph Amanda Hoover Nikol Zurita yrginla Arrington Janell Wallace Contrac is Signature STATE OF FLORIDA COUNTY OF Jorge Suarez Ashley Ziegengeist Melissa Flemming Cameron Christensen Contractor's Printed Name The foregoing instrument was acknowledged before me this ___jam_ day of Or , 20 1_ by Cameron Christensen who is plLaonally known to me or has produced as identification. NOTARY PUBLIC tpRy Aimee McGurn oP NOTARY PUBLIC ESTATE OF FLORIDA 2 Comm# GG200147 sNCE 19 0 Expires 10/23/2021 JR81EQUI[RIEpD I[ NSF EcG'I R 131?# i aNilfitai PERM 7 l nIIll Max1us eodi®n 1 D@scIl'Il ill®nn. Footer / Setback Remwall ! Foundatiozi / Form Board.*Survey Slab % Mono Slab -Pre our Lintel / Tie- Beam / Fill / Down Cell Sheathing ; Wails- Sheathing ! Ro'ofRoof Dry Ih I Frame Insulation Rough In IFirewall Screw Pattern Drywall / Sheetrock Lath Ins : ection Final Solar ! Final' Roof Final Stucco / .Siding Insulation Final Final Utility; Building` Final Door ! Final Window i FinalScreen.Room Final. Pool Screen Enclosure. Mobile Home Building Final Pre. - Demo ! Final Demo I i Final' Single Family., Residence, Final. Building Other I I RlMS EIlD: Ame 2014 i D1Y ] E T1E1:cCIE: i iqUWe P`1EQ RrUW' ImnIl max ! I[n s dE. ]iDDesE A 2fllom Electric. Underground Footer /' Slab Steel Bond Electric Rough T. U.G. I Pre -Power Final Electric Final 7 r. t"/ui.'' 14\(pY C AitY'• 1,.'.,w[\l+ Yn JL•JT y.3'VS.r `y.(iw ti.'. G>.''.; .L rr • :L4,;=5'.r.+`v`L't. "•^'^T• = 9EY' ..) a.: Mk max. ! Ilnme flonn IIDese-Ai flolm Plumbing Underground Plumbing Sewer . Plumbing Tub Set PlumlAng Final I i IG` L3YJl'24RWI.VMechanical Rough Mechanical. Final I• i IlIIIl max IC n ec tionn.1 Des-eld flona Gas Underground Gas Rough Gas- Final i 1 L RECORD COPY PLAN KEY PV-1 COVER PAGE PV_ 1.1 COVER PAGE CONT. PV-2 PANEL LAYOUT PV-3 LAYOUT DETAIL PV-4 THREE LINE DIAGRAM PV-4.1 ELECTRICAL CONT. PV-4.2 EQUIPMENT LABELS 71 HANWHA Q.PEAK DUO BLK-G5 315 315 WATT MODULE 66.3" X 39.4" X 1.26" SEE DATASHEET) BILL OF MATERIALS MODULES 26 INVERTERS 26 CLAMP ASSEMBLY 79 COUPLING ASSEMBLY 40 BONDING CLIP 6 SKIRTS 10 ENPHASE COMBINER BOX 1 SQUARE-D 60A FUSIBLE AC DISCONNECT 1 40A FUSES 2 125A LINE TAPS 2 SYSTEM INFORMATION MODULE HANWHA Q.PEAK DUO BLK-G5 315 INVERTER ENPHASE IQ7-60-2-US RACKING ECOFASTEN ROCK -IT SYSTEM SYSTEM SIZE (DC) 8.19:KW LOCATION 28.794332,-81.317483 GENERAL NOTES: THIS PV SYSTEM HAS BEEN DESIGNED TO MEET THE MINIMUM DESIGN STANDARDS FOR BUILDING AND OTHER STRUCTURES OF THE ASCE 7-10, 6TH EDITION 2017 FLORIDA RESIDENTIAL CODE, 6TH EDITION 2017 FLORIDA FIRE PREVENTION CODE, NEC 2014 AND ALL LOCAL CODES & ORDINANCES. ROOF SHALL HAVE NO MORE THAN TWO LAYERS OF COVERING IN ADDITION TO THE SOLAR EQUIPMENT. INSTALLATION OF SOLAR EQUIPMENT SHALL BE FLUSH MOUNTED, PARALLEL TO AND NO MORE THAN 6-INCHES ABOVE THE SURFACE OF THE ROOF. ANY PLUMBING VENTS ARE NOT TO BE CUT OR COVERED FOR SOLAR EQUIPMENT INSTALLATION. ANY RELOCATION OR MODIFICATION OF THE VENT REQUIRES A PLUMBING PERMIT AND INSPECTION. ALL DESIGN, CALCULATIONS ARE PERFORMED BY DANIEL DUNZIK REGISTERED ARCHITECT. FLORIDA STATE STATUTE 471.003(3) PROVIDES THAT LICENSED ARCHITECTS ARE EXEMPTED FROM THE PROVISIONS OF CHAPTER 471 ENGINEERING AND NOT PRECLUDED FROM PERFORMING ENGINEERING SERVICES FOR INTEGRATED SYSTEMS AND SERVICES THAT ARE INCIDENTAL TO BUILDINGS AND STRUCTURES. INVERTER PLACEMENT: SYSTEM UTILIZES "ENPHASE" MICRO -INVERTERS WITH RAPID SHUTDOWN CONTROL LOCATED ON THE BACK SIDE OF EACH MODULE. STRUCTURAL STATEMENT: THE EXISTING STRUCTURE IS ADEQUATE TO SUPPORT THE NEW LOADS IMPOSED BY THE PHOTOVOLTAIC MODULE SYSTEM INCLUDING UPLIFT & SHEAR.EXISTING RAFTER SIZES & DIMENSIONS CONFORM TO 6TH EDITION 2017 FLORIDA RESIDENTIAL CODE MOUNTING BRACKETS AND HARDWARE MEET OR EXCEED FLORIDA CODE REQUIREMENTS FOR THE DESIGN CRITERIA OF THE TOWN. CLIMATIC & GEOGRAPHIC DESIGN CRITERIA TABLE R301.2(1) SPEED (MPH) 150 TOPOGRAPHIC EFFECTS B SPECIAL WIND REGION NO WIND BORNE DEBRIS ZONE. 2 SEISMIC DESIGN CATEGORY C CLIMATE ZONE 2A WIND EXPOSURE CATETORY B REVIEWED FOR CODE COMPLIANCE se PLANS EXAMINER DATE SANFORD BUILDING DIVISION A PERMIT ISSUED SHALL BE CONSTRUED TO BE ALICENSETOPROCEEDWITHTHEWORKANDNOTASAUTHORITYTOVIOLATE, CANCEL, ALTER OR SETASIDEANYOFTHEPROVISIONSOFTHETECHNICALCODES, NOR SHALL ISSUANCE OF A PERMIT PREVENTTHEBUILDINGOFFICIALFROMTHEREAFTER REQUIRING TI CONSRUCTON OR VIOLATIONS OF HIS CODE FBC, Residential 2017 TABLE R301.2.1.3 WIND SPEED CONVERSIONSa Vint 110 115 120 130 140 150 160 170 180 190 200 Vasd 85 89 93 101 108 116 124 132 139 147 155 For SI: 1 mile per hour = 0.447 m/s. a. Linear interpolation is permitted. 1 8- 4258 gUILp\ r c momentum SOLAR PRO CUSTOM SOLAR LLC D.B.A. MOMENTUM SOLAR 325 HIGH STREET, METUCHEN, NJ 08840 732) 902-6224 MOMENTUM SOLAR. COM sty. AR98?9r F SOLAR CONTRACTOR CAMERON CHRISTENSEN CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER: CVC57036 MOMENTUM SOLAR 5728 MAIOR BLVD. SUITE 307 ORLANDO FL. 32819 RAZIBUL ISLAM 102 SPLITLOG PLACE SANFORD, FL, 32771 770) 771-4663 PV SYSTEM INFORMATION SYSTEM SIZE (DC): 8.19 KW 26 MODULES: HANWHA Q.PEAK DUO BLK-G5 315 26 INVERTERS: ENPHASE IQ7-60-2-US I PROJECT INFORMATION I I INITIAL I DATE: 10/12/2018 1 DESIGNER: TI I IREV: IDATE: (DESIGNER: LiREV: I DATE: DESIGNER: COVER PAGE 1:,"', ' 1. ALL WIND DESIGN CRITERIA ARE FOR GABLE AND HIP RESIDENTIAL ROOFS CONSIDERED FROM AN ANGLE OF MIN. 9.5 ° (j) TO MAX. 45° (if) NOT TO EXCEED 30' MEAN ROOF HEIGHT WITH A MIN " LAG BOLT (ASTE A276) STAINLESS STEEL INTO THE RAFTER OR BLOCKING BETWEEN RAFTERS W/ MIN. EMBEDMENT OF 3" 2. THIS STRUCTURAL DESIGN REFLECTS STRUCTURAL CONNECTIONS TO THE EXISTING STRUCTURE ONLY. MODULE TO RACK -IT LOADING AND CERTIFICATION PER MECHANICAL LOAD TESTS IAW/ANSI UL2703 CONDUCTED ON BEHALF OF ECOLIBRIUM SOLAR BY TUV RHEELAND REFERENCE FILE L2-ELS150128a (REV 1) 3. ROOF SEALANTS SHALL CONFORM TO ASTMC920 AND ASTM 6511 AND IS THE RESPONSIBILITY OF THE CONTRACTOR TO FILL ALL HOLES WATER TIGHT. 4. "ROCK -IT" ATTACHMENTS ARE MANUFACTURED BY ECOFASTEN SOLAR ARIZONA. AND SHALL BE INSTALLED IN STRICT COMPLIANCE WITH MANUFACTURERS PRINTED INSTRUCTIONS. ROCK -IT TO RAFTER ATTACHMENT SPACING SCHEDULE ULTIMATE ROOF ZONE 1 ROOF ZONE 2 & 3DESIGNMAX. SPAN / MAX. MAX. SPAN / MAX. WIND CANTILEVER CANTILEVERSPEED MPH) INCHES) INCHES) 125 48" O.C. / 16" MAX. 32" O.C. / 12" MAX. 130 48" O.C. / 16" MAX. 32" O.C. / 12" MAX. 140 48" O.C. / 16" MAX. 24" O.C. / 10" MAX. 150 40" O.C. / 16" MAX. 16" O.C. / 8" MAX. 160 32" O.C. / 12" MAX. 16" O.C. / 8" MAX. 170 32" O.C. / 12" MAX. 14" O.C. / 8" MAX. TABLE REFLECTS ATTACHMENT SPACINGS THAT EXCEED MANUFACTURERS SPECIFICATIONS FOR WIND LOADS AS PER ASCE 07-10. RISK CATEGORY II TOPOGRAPHIC EFFECTS B,C, & D AND ROOF WIND ZONES 1,2,& 3. ROOF ZONES 2 & 3 ARE WITHIN 48" OF ANY OUTER EDGE, HIP, RIDGE, OR GUTTER LINE FOR STRUCTURES 30'- 0" OR LESS MEAN ROOF HEIGHT. U. 4 U. a Q GUTTER K I I ml1il hi fl GUTTER Q W r_ RIDGE ® m Q GUTTER 01 ROOF WIND ZONES AS PER IRC R301.2(7) ROOF ZONES 2 & 3 ARE 48" FROM OUTER ROOF EDGES, RIDGES, HIPS, RAKES, AND GUTTER EDGES FOR STRUCTURES BELOW 30'-0" MEAN ROOF HT. SOLA CO CL AT SOLAI SEE ATTACHMENT SCHEDULE FOR MAXIMUM CANTILEVER ECOFASTEN SOLAR ROCK -IT 4.0 MOUNTING DETAIL ECOFASTEN SOLAR ROCK -IT 4.0 RAIL -LESS MOUNTING SYSTEM INTEGRATED WITH FLASHING, COUPLINGS AND ADJUSTABLE CLAMP ATTACHMENTS SEE ATTACHMENT SCHEDULE FOR MAXIMUM CANTILEVER ECOFASTEN SOLAR ROCK -IT 4.0 MOUNTING DETAIL ECOFASTEN SOLAR ROCK -IT 4.0 RAIL -LESS MOUNTING SYSTEM INTEGRATED WITH FLASHING, COUPLINGS AND ADJUSTABLE CLAMP ATTACHMENTS MAXIMUM SOLAR ARRAY ELEVATION: 4.25" MAXIMUM CLAMP ATTACHMENT SPACING: 48" rni ioi 1— 1 r. wu momentum SOLAR PRO CUSTOM SOLAR LLC D.B.A. MOMENTUM SOLAR 325 HIGH STREET, METUCHEN, NJ 08840 732) 902-6224 MOMENTUM SOLAR. COM STRUCTURAL OF ft qy Vv lly,"D A'g SOLAR CONTRACTOR CAMERON CHRISTENSEN CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER: CVC57036 MOMENTUM SOLAR 5728 MAJOR BLVD. SUITE 307 ORLANDO FL. 32819 RAZIBUL ISLAM 102 SPLITLOG PLACE SANFORD, FL, 32771 770) 771-4663 SOLID BLOCKING I r® v® v r •.0-1 BETWEEN JOISTS I N FO RMATIO N 0zm w SYSTEM SIZE (DC): 8.19 KW 26 MODULES: HANWHA Q.PEAK DUO BLK-G5 315 UIFO tRogc-R 26INVERTERS: ENPHASE IQ7-60-2-US ATAQIW SMIN 4WASIFN V124' Sam kwa RAM EbST10i ROW I WA& FfOFASIHr sw FPLYMM OHJI; AND PROJECT INFORMATION RM INITIAL DATE: 10/12/2018 DESIGNER: TI REV: DATE: DESIGNER: M REV: DATE: DESIGNER: COVER PAGE All MWE SM K AS YNIiOM N UITC HI MW AID ESTAIID 0 sw MIMItf ®AI WOOfACIUm RaM mom I SCALE: 3/32" = V-0" ROOF PANELCOUNT TILT AZIMUTH SHADING R1 26 26° 180° 96% momentum SOLAR PRO CUSTOM SOLAR LLC D.B.A. MOMENTUM SOLAR 325 HIGH STREET, METUCHEN, NJ 08840 732) 902-6224 MOMENTUMSOLAR.COM GUTTER ELECTRICAL EQUIPMENT SOLAR INSTALLER NOTES: NO ADDITIONAL STRUCTURAL SUPPORT REQUIRED NOTE: 1. ROOF COVERING MATERIAL IS COMPOSED OF SINGLE LAYER ASPHALT COMPOSITE SHINGLE. 2. REFER TO LAYOUT DETAIL DRAWING PV-3 FOR ALL ROOFTOP DIMENSIONS. INEERIN SOLAR CONTRACTOR CAMERON CHRISTENSEN CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER: CVC57036 MOMENTUM SOLAR 5728 MAJOR BLVD. SUITE 307 ORLANDO FL 32819 CUSTOMER INFORMATION RAZIBUL ISLAM 102 SPLITLOG PLACE SANFORD, FL, 32771 SYMBOL LEGEND 770) 771-4663 PV SYSTEM INFORMATIONMSPMAINSERVICEPANELCHIMNEY SYSTEM SIZE (DC): 8.19 KW 26 MODULES: HANWHA Q.PEAK DUO BLK-G5 315 26 INVERTERS: ENPHASE IQ7-60-2-US ESP SUB -PANEL z SKYLIGHT UTILITY METER VENT AC DISC AC DISCONNECT 0 PIPE VENT UDC UTILITY DISCONNECT FAN PROJECT INFORMATION INITIAL DATE: 10/12/2018 DESIGNER: TI LC LOAD CENTER r// SATELLITE DISH REV: DATE: DESIGNER: N3R NEMA 3R BOX W/ ENVOY-S FIRE SETBACKS AS PER 6TH EDITION 2017 FFPC REV: DATE: DESIGNER: CB COMBINER BOX MIN TxT GROUND ACCESS POINT PANEL LAYOUT Flo MODULE PITCH DIRECTION PV _ 2 R1 - ARRAY 1 LAYOUT DETAIL SCALE: 3/16" = 1'-0" TILT: 26° AZIMUTH: 180' SHADING:96% M SOLAR INSTALLER NOTES: NO ADDITIONAL STRUCTURAL SUPPORT REQUIRED momentum SOL.4.R PRO CUSTOM SOLAR LLC D.B.A. MOMENTUM SOLAR 325 HIGH STREET, METUCHEN, NJ 08840 732) 902-6224 MOMENTUMSOLAR.COM STRUCTURAL ENGINEERING OF F/ 7 IF 1 z SOLAR CONTRACTOR CAMERON CHRISTENSEN CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER: CVC57036 MOMENTUM SOLAR 5728 MAJOR BLVD. SUITE 307 ORLANDO FL. 32819 CUSTOMER INFORMATION 1 z RAZIBUL ISLAM 102 SPLITLOG PLACE SANFORD, FL, 32771 770) 771-4663 PV SYSTEM INFORMATION SYSTEM SIZE (DC): 8.19 KW 26 MODULES: HANWHA Q.PEAK DUO BLK-G5 315 26 INVERTERS: ENPHASE IQ7-60-2-US PROJECT INFORMATION INITIAL DATE: 10/12/2018 DESIGNER: TI REV: DATE: DESIGNER: REV: DATE: DESIGNER: LAYOUT DETAIL PV-3 PV MODULE RATINGS INVERTER RATINGS VOLTAGE DROP CALCULATIONS MODULE MAKE HANWHA INVERTER MAKE ENPHASE FORMULA USED PER NEC 2014 HANDBOOK 215.2(A)(4) WHERE APPLICABLE MODEL Q.PEAK DUO MODEL IQ7-60-2-US WIRE RUN V'P I'P R L (FT) VD % Vo WIRE SIZE momentumBLK-G5 315 MAX POWER 315W MAX OUTPUT POWER 240W BRANCH TO ]-BOX 240.00 13 1.98 85.58 4.406 1.84% 12 AWG SOLAR OPEN CIRCUIT VOLTAGE 40.29V OPEN DC VOLTAGE 48V ]-BOY: TO LOAD o240.00 26 1.24 50.00 3.224 1.34/0 10 AWG NOMINAL AC VOLTAGE 240V CENTER PRO CUSTOM SOLAR LLC D.B.A. MOMENTUM SOLAR MPP VOLTAGE 33.46V 325 HIGH STREET, METUCHEN, NJ 08840 LOAD CENTER TO AC' (732) 902-6224 SHORT CIRCUIT CURRENT 9.89q MAX AC CURRENT 1A DISCONNECT 240.00 32.5 0.778 3.00 0.152 0.06% 08 AWG MOMENTUMSOLAR.COM MPP CURRENT 9.41A CEC INVERTER EFFICIENCY 97% AC DISCONNECT TO 240o STRUCTURAL NUMBER OF MODULES 26 NUMBER OF INVERTERS 26 INTERCONNECTION .00 32.5 0.491 10.00 0.319 0.13/0 06AWG ENGINEERING UL1703 COMPLIANT YES UL1703 COMPLIANT YES SUB PANEL # OF MODULES PV BREAKERTHIS SOLAR PHOTOVOLTAIC SYSTEM COMPLIES WITH THE 2017 PERBRANCHBREAKER SIZE IFLORIDA BUILDING CODE AND THE 2014 NATIONAL ELECTRICAL CODE ,`p. .• UP TO 16 20A 'Q,O P EL W. p •.7 26 HANWHA Q.PEAK DUO BLK-G5 315 315W MODULES PAIRED WITH 26 ENPHASE IQ7-60-2-US MICRO -INVERTERS F QcD ARG` BRANCHCIRCUITA13 MICRO -INVERTERS EXISTING SQUARE D BRANCH CIRCUIT B UTILITY 200A SUB PANEL 240 V 13 MICRO -INVERTERS METER MAIN BREAKER: A GRID AC COMBINER SOLAR CIRCUIT p SOLAR CONTRACTOR BOX DISCONNECTING MEANS ll CAERON CHRISTENSEN A LIC M NSEENUM ER: CVCS SOLAR CONTRACTOR J1 `f1 `/•+ SQUARE-D 60A FUSIBLE MOMENTUM SOLAR 5728 AC DISCONNECT - LINE SIDE ORLAND]OR BLVD. 3281 SUITE 307 ORLANDO R. 32R79 ail HOT TAP aoA_j - CUSTOMER INFORMATION SOLADECK 10A BREAKER JPOWER RAZIBUL (SLAM JUNCTION (ENVOY) 7-GROUND 102 SPLITLOG PLACE 40A FUSES - SANFORD, FL, 32771 TERMINATION CAP 1 BOX 2A-B 20A BREAKER (A) 3 4 EXISTING 150A (770) 771-4663 INSTALLED ON 20A BREAKER ( B) EXTERIOR MAIN PV SYSTEM DISCONNECT ENDOF CABLE 150A BREAKER INFORMATION SYSTEM SIZE ( DC): 8.19 KW 26 MODULES: HANWHA Q.PEAK DUO BLK-G5 315 26 INVERTERS: ENPHASE IQ7-60-2-US Wire Temp. Wire Temp. Conduit Derated Inverter NOC NEC Design Ground Ground Wire Wire TagConduitWireQtyGaugeWireTypeRatingAmpacity ( A) Derate Fill Derate Ampacity (A) Qty (A) Correction Current ( A) Size Type PROJECT INFORMATION 1 OPEN AIR 2 12 AWG Trunk Cable 90°C 30 0.96 1 28.80 13 1 1.25 16.25 12 AWG Trunk Cable INITIAL DATE: 10/12/2018 DESIGNER: TI REV: DATE: DESIGNER: 2A 1" PVC 2 10 AWG THWN-2 90°C 40 0.96 0.8 30.72 13 1 1.25 16.25 08 AWG THWN-2 REV: DATE: DESIGNER: 26 1" PVC 2 10 AWG THWN-2 90°C 40 0.96 0.8 30.72 13 1 1.25 16.25 08 AWG THWN-2 ELECTRICAL 3 1" PVC 3 08 AWG THWN-2 75°C 50 0.96 1 48.00 26 1 1.25 32.50 08 AWG THWN-2 4 1" PVC 3 06 AWG THWN 2 75°C 65 0.96 1 62.40 26 1 1.25 32.50 THWN-2 PV-4 ELECTRICAL NOTES: 1. ALL CALCULATIONS FOR VOC, VMAX, IMP AND ISC HAVE BEEN CALCULATED USING THE MANUFACTURED STRING CALCULATOR BASED ON ASHRAE 2% HIGH AND EXTREME MINIMUM TEMPERATURE COEFICIENTS. 2. THE ENTIRE ARRAY IS BONDED ACCORDING TO (NEC 690.46 - 250.120 paragraph C). THE GROUND IS CARRIED AWAY FROM THE GROUNDING LUG USING #6 BARE COPPER WIRE. 3. THIS SYSTEM COMPLIES WITH NEC 2014 4. BRANCH CIRCUIT CALCULATION FOR WIRE TAG 1 DISPLAYS THE LARGEST BRANCH CIRCUIT IN SYSTEM. OTHER BRANCH CIRCUITS WILL HAVE LOWER DESIGN CURRENT THAN THE ONE SHOWN. IN ADDITION, VOLTAGE DROP CALCULATIONS FROM PANELS TO THE COMBINER BOX WILL BE SHOWN IN A SIMILAR FASHION 5. ALL CONDUCTORS ARE SIZED BASED ON NEC 2014 ARTICLE 310 6. ALL EQUIPMENT INSTALLED IS RATED AT 90°C 7. INVERTER NOC (NOMINAL OPEN CURRENT) OBTAINED FROM EQUIPMENT DATASHEET 8. CONTRACTOR RESPONSIBLE FOR COMPLYING WILL ALL LOCAL OR NATIONAL CODE REQUIREMENTS AND EQUIPMENT INSTALLATION INSTRUCTIONS 9. EACH MODULE MUST BE GROUNDED ACCORDING TO SUNMODULE USER INSTRUCTIONS 10. ALL EQUIPMENT SHALL BE LISTED PER NEC 690.4(D) 11.PER NEC 690.17, PROVIDE A WARNING SIGN AT ALL LOCATIONS WHERE TERMINALS OF THE DISCONNECTING MEANS MAY BE ENERGIZED IN THE OPEN POSITION> SIGN SHALL READ *WARNING - ELECTRIC SHOCK HAZARD - DO NOT TOUCH TERMINALS - OR EQUIVALENT. 12. PER NEC 705.10, PROVIDE A PERMANENT PLAQUE OR DIRECTORY SHOWING ALL ELECTRIC POWER SOURCES ON THE PREMISES AT SERVICE ENTRANCE. 13. INTERCONNECTION METHOD SHALL COMPLY WITH NEC 690.64 14. AND OPTION FOR A SINGLE CIRCUIT BRANCH TO BE SPLIT INTO TWO SUB -CIRCUIT BRANCHES IS ACCEPTABLE. 15. ALL CONDUCTORS MUST BE COPPER. 16. NEUTRAL AND EQUIPMENT GROUNDING CONDUCTOR BONDED AS PER NEC 250.24(C). 17. EQUIPMENT GROUNDING CONDUCTOR IS CONNECTED TO A GROUNDING ELECTRODE SYSTEM PER 250.54(D). 18. FUSES FOR PV DISCONNECT HAVE AIC RATINGS OF 200KA AC AND 20KA DC. 19. SUPPLY SIDE CONNECTION SHALL BE MADE USING ILSCO INSULATION PIERCING CONNECTORS (IPC). MAKE, MODEL, AND RATING OF INTERCONNECTION CAN BE SEEN ON TABLE 1 BELOW. 20. METHOD OF INTERCONNECTION CAN BE SEEN IN FIGURE 1. 21. UTILITY HAS 24-HR UNRESTRICTED ACCESS TO ALL PHOTOVOLTAIC SYSTEM COMPONENTS LOCATED AT THE SERVICE ENTRANCE. 22. WORKING CLEARANCES AROUND THE EXISTING AND NEW ELECTRICAL EQUIPMENT WILL BE MAINTAINED IN ACCORDANCE WITH NEC ARTICLE 110.26. 23. CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS SUNLIGHT RESISTANT PER NEC ARTICLE 300.6 (C)(1) AND ARTICLE 310.8 (D). 24. CONDUCTORS EXPOSED TO WET LOCATIONS SHALL BE SUITABLE FOR USE IN WET LOCATIONS PER NEC ARTICLE 310.8 (C). 25. TOTAL AREA OF ALL CONDUCTORS, SPLICES, AND TAPS INSTALLED AT ANY CROSS SECTION OF THE WIRING DOES NOT EXCEED 75% OF THE CROSS SECTIONAL AREA OF THE SPACE. NEC 312.8(2). 26. SYSTEM IS CONSIDERED AN AC MODULE SYSTEM. NO DC CONDUCTORS ARE PRESENT IN CONDUIT, COMBINER, JUNCTION BOX, DISCONNECT. AND COMPLIES WITH 690.6 - NO DC DISCONNECT AND ASSOCIATED DC LABELING ARE REQUIRED. 27. SYSTEM COMPLIES WITH 690.12 RAPID SHUTDOWN AND ASSOCIATED LABELING AS PER 690.56(C). AC VOLTAGE AND SYSTEM OPERATING CURRENT SHALL BE PROVIDED 690.52. 28. CONDUCTORS IN CONDUIT ARE AC CONDUCTORS BRANCH CIRCUITS AND NOT PV SOURCE CIRCUITS. 690.6. 29. ALL GROUNDING SHALL COMPLY WITH 690.47(A) IN THAT THE AC MODULES WILL COMPLY WITH 250.64, 30. NO TERMINALS WILL BE ENERGIZED IN THE OPEN POSITION IN THIS AC MODULE SYSTEM 690.17, 690.6. 31. WHERE APPLICABLE: INTERCONNECTION SHALL COMPLY WITH 705.12(D)(3), 705.12(D)(2)(3)(B), 705.12(A) AS PERMITTED BY 230.86(6) TABLE 1: MAKE MODEL VOLTAGE CONDUCTOR CONDUCTOR RATING RANGE MAIN RANGE TAP ILSCO IPC 4020 600 V 4/0-4 AWG 6-14 AWG ILSCO IPC 4006 600 V 4/0-2 AWG 2/0-6 AWG FIGURE 1: 1.Adjust the connector 2.Put the branch wire 3.Insert the mein wire,if there are nut to suitable location Into the capsheath fully two lays of insulated lay In the main cables,should strip a certain length of the first Insulated lay from inserted 4.Turn the nut by hand,and S.Screw the nut with the sleeve 6.Screw the nut continually until the fix the connector In suitable spanner. top part Is cracked and dropped down. location 2 q • - ntum SOLAR PRO CUSTOM SOLAR LLC D.B.A. MOMENTUM SOLAR 325 HIGH STREET, METUCHEN, NJ 08840 732) 902-6224 MOMENTUMSOLAR.COM STRUCTURAL O F F o' D AR 8 5/e F' D A G\ SOLAR CONTRACTOR CAMERON CHRISTENSEN CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER: CVC57036 MOMENTUM SOLAR 5728 MAJOR BLVD. SUITE 307 ORLANDO FL. 32819 INFORMATIO RAZIBUL ISLAM 102 SPLITLOG PLACE SANFORD, FL, 32771 770) 771-4663 PV SYSTEM INFORMATIO SYSTEM SIZE (DC): 8.19 KW 26 MODULES: HANWHA Q.PEAK DUO BLK-G5 315 26 INVERTERS: ENPHASE IQ7-60-2-US PROJECT INFORMATION INITIAL DATE: 10/12/2018 DESIGNER: TI REV: DATE: DESIGNER: REV: DATE: DESIGNER: ELECTRICAL PV-4.1 TAG LABEL QUANTITY LOCATION NOTE EXAMPLES momentum SOLAR OPANEL1MAIN SERVICE POINT OF INTERCONNECTION AI• O j' PRO CUSTOM SOLAR LLC D.B.A. MOMENTUM SOLAR 325 HIGH STREET, METUCHEN, NJ 08840 732) 902-6224 MOMENTUMSOLAR.COM II a>a STRUCTURAL ENGINEERING RNINGzEWA-A! WARNING PHOTOVOLTAIC - • • THIS • EQUIPMENT • FED • ALL OVERCURRENT DEVICES, EXCLUDING MAIN SUPPLYPHOTOVOLTAICSYSTEMOVERCURRENTDEVICE, SHALL NOT EQUIPPED RAPI. SHUTDOWN 1 COMBINER BOX 1 AT ANY JUNCTION BOX OR DC COMBINER IF USED OF FL o E W. D Z 9 O r • 1. SHOCKzj\WARNING' ELECTRICAL -. NOT TOUCH TERMINALS 1 JUNCTION BOX 1 AT ANY JUNCTION BOX OR DCDOCOMBINERIFUSED T TF L TERMINALS ON BOTH LINE AND SIDES MAY BE ENERGIZED IN THE OPEN POSITION PHOTOVOLTAIC AC DISCONNECT I\WARNING SOLAR CONTRACTOR O OPERATING CURRENT26.00A SHOCKELECTRICAL - NOT TOUCHMOMENTUM OPERATION V•LTAGE 264V TERMINALS ON BOTH LINE AND OPEN -POSITION PHOTOVOLTAIC SYSTEM 325 HIGH STREET 1 AC DISCONNECT 1 OF EACH AT FUSED AC DISCONNECT COMPLETE VOLTAGE AND CURRENT VALUES ON DISCONNECT LABEL AC DISCONNECTORLANDO mOe ter" CAMERON CHRISTENSEN CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER: CVC57036 SOLAR 5728 MAJOR BLVD. SUITE 307 FL. 32819 CUSTOMER INFORMATION RAZIBUL ISLAMMETUCHEN, NJ 08840 t--WARNING-; 732-902-6224 p 102 SPLITLOG PLACE SANFORD, FL, 32771 PV SYSTEMLINESIDETAPztWARNING INFORMATION O DUAL POWER SOURCE SYSTEM 1 MAIN DISCONNECT PANEL 1 OF EACH AT BUILDING MAIN DISCONNECT PANEL SYSTEM SIZE (DC): 8.19 KW 26 MODULES: HANWHA Q.PEAK DUO BLK-GS 315 r 26 INVERTERS: ENPHASE IQ7-60-2-US RATED AC OPERATING CURRENT2600A- r, FO PROJECT INFORMATION INITIAL DATE: 10/12/2018 DESIGNER: TI REV: DATE: DESIGNER: O AWARNING CE SECOND SOURCE PHOTOVOLTAICWER •-EQUIPMENT SYSTEM 1 UTILITY METER 1 AT UTILITY METER t It10.61 M.L R9i '.'.=. -'""- '" •, .•• REV: DATE: DESIGNER: DUAL LABELS PV-4.2 Daniel W. DUnzik Architect LEED-AP 370 Burnt Hill Rd. Skillman, NJ. 08558 908-872-3664 Studiogdesign@comcast.net October 11, 2018 Sanford, FL Attn: Construction Official Re: Proposed Photovoltaic Solar Panel Installation Razibul Islam 102 Splitlog Pl. Sanford, FL 32771 Dear Sir: Certification: I have reviewed the engineering testing reports for the racking and attachments to be used on this project and I certify that the products are capable of supporting the code required loads and are suitable for this installation when installed in strict compliance with the manufacturers printed instructions. Regarding the solar panel array installation on the above referenced project please note that An inspection was performed and analysis of the existing structure was conducted. There is adequate structural capacity for the installation of the array with the following recommendations: 1. The array will be installed on the existing roof. The roof is constructed of 2"x4" wood trusses @ 24" O.C. spanning 12'11" with a top chord length of 20'3" with intermediate supports at 1/4th points making the effective longest span 5'6" with 1/2" OSB plywood sheathing. The new array (See Site map by contractor) will add 2.63 Lb. / Sf. overall to the roof. No additional structure support is required for the existing roof structure. 2. The system shall be secured to the roof using the "Ecofasten Solar" "Rock -IT" ® attachment system. The installation shall be in strict compliance with manufacturers printed instructions. The attachment system shall be UL 1703 approved tested. The attachments shall be min. 5/16" x 4" long stainless -steel lags with a min. embedment of 3.25" into the rafters. Attachments shall be @ 48" o.c. Max. in roof wind zone 1 and @ 24" o.c. Max. in roof wind zone 2 and 3 lags to alternate rafters. Provide 6 mil. vapor barrier between dissimilar metals. Provide water tight gasket and sealant at all penetrations. Attachments shall follow panel rows as specified by the system manufacturer's installation manual. The panel angle shall match the roof slope. Structural Design Loads per ASCE 7-10 Dead Loads = 10 psf (+2.6psf, New Solar Panels) = 12.6 psf.- Live Load =20psf Total dead weight on attachment = 19Lb. Max. Ch. 30 Wind Loads Components and Cladding windloads = 140 mph Exposure B zone 1=+/- 31.4 psf., Zone 2&3=+/-77.7psf. Area of Panels largest array = 452.4sf Tributary area panels/attachment max. 452.4sf/ 56min = 8sf. Min Number of Attachments =56. Wind pressure 31.4 x Area 452.4/ 56 No. Attachments = 627 TABLE 10.3.1 NDS Pull out strength of 5/16"x4" lags in rafter =W'= WxCdxCt=266lbs/in embedment x 3.25"embedment = 864.5 xl.6Cd x1.00t = 1,383 Lbs Max. > 6271bs/attachment Daniel W. Dunzik Architect LEED-AP 370 Burnt Hill Rd. Skillman, NJ. 08558 908-872-3664 Studiogdesigns@comcast.net OK 3. Solar modules shall be UL-1703 rated. Refer to manufacturers specifications sheets. 4. Positive drainage of the system shall be so as not to void the existing roof warrantee. 5. Florida Administrative Code, 2017 Florida Building Code - Residential Sixth Edition, ASCE-7-10, 2017 Florida Building Code — Energy Conservation, Sixth Edition, 2014 National Electric Code, All Local Governing County and Municipal Ordinances adopted by reference or enacted by law. All components used meet the criteria of the Florida Solar Energy Center. If you have any questions relating to this matter, please contact me at your earliest convenience. Thank you. OF• Ft O AR98795 •• FRED A G Daniel W. Dunzik, RA. LEED-AP FL. Lic. No. AR98795 Digitally signed by: Daniel W. Dunzik DN: CN = Daniel W. Dunzik email STUDIOGDESIGN@COMCAST. NET C = AD O = RA. LEED-AP OU = FI. Lin. No.AR98795 Date: 2018.10.11 15:19:31-05'00' Daniel W. Dunzik Architect LEED-AP 370 Burnt Hill Rd. Skillman, NJ. 08558 908-872-3664 January 29, 2018 Building Department Attn: Plan Reviewer Re:Proposed Photovoltaic Solar Panel Installation Dear Sir: I have reviewed the following documents related to the " EcoFasten Solar" ROCK -IT SYSTEM 4.0 and certify that the attachment system when installed in strict compliance with the manufacturers Installation Manual appropriate for this application and is in compliance with the latest building codes including Florida Administrative Code, 2017 Florida Building Code - Residential Sixth Edition, ASCE-7-10, 2017 Florida Building Code — Energy Conservation, Sixth Edition, 2014 National Electric Code, All Local Governing County and Municipal Ordinances adopted by reference or enacted by law. I make this certification for the following listed documents: 1. ROCK -IT SYSTEM 4.0 Installation Manual 2. PZSE, Inc Structural Engineers Certification, 3. EcoFasten Solar Certificate No. US 82150026 4. ROCK -IT SYSTEM 4.0 Cut Sheet for Coupling, Hybrid Coupling, and Mount. If you have any questions relating to this matter, please contact me at your earliest convenience. Thank you. Daniel W. Dunzik, RA. LEED-AP Fl. Lic. No. AR98795 Digitally signed by: Daniel W. Daniel Dunzik DN: C14 = Daniel W. Dunzik mZil studiggdesign@comcast.netDunzik C = AD O = Lic No AR98795 OUA- Architect Date: 2018.01.2918:19:36 - 05'00' GFfi IEL W -c AR98795 powered by DUO The new iA. PEAK DUO BLK-G5 solar module from Q CELLS impresses with its outstanding visual appearance and particularly high performance on a small surface thanks to the innovative Q.ANTUNII W-!0 Technology. Q.ANTUM's world -record -holding cell concept has now been combined with state-of-the-art circuitry half cells and a six-busbar design, thus achieving outstanding performance under real conditions — both with low -intensity solar radiation as well as on hot, clear summer days. Q.ANTUM TECHNOLOGY: LOW LEVELIZED COST OF ELECTRICITYGHigheryieldpersurfacearea, lower BOS costs, higher power classes, and an efficiency rate of up to 19.3 %. INNOVATIVE ALL-WEATHER TECHNOLOGY Optimal yields, whatever the weather with excellent low -light and temperature behavior. a ENDURING HIGH PERFORMANCE Long-term yield security with Anti LID Technology, Anti PID Technology', Hot -Spot Protect and Traceable Quality Tra.QTM EXTREME WEATHER RATING 1 High-tech aluminum alloy frame, certified for high snow 5400 Pa) and wind loads (4000 Pa) regarding I EC. O A RELIABLE INVESTMENT Inclusive 12-year product warranty and 25-year linear performance guarantee2. STATE OF THE ART MODULE TECHNOLOGY Q.ANTUM DUO combines cutting edge cell separation and innovative wiring with Q.ANTUM Technology. THE IDEAL SOLUTION FOR: C5Rooftop array% on residential bulldmp Engineered in Germany QQELLS TOP WAMD rtl 2018 Ou* Tbrted D. 40D32687 APT test conditions according to IEC/rS 62804-1:2015, method B (-1500V, 168h) See data sheet on rear for further information. OCELLS SPECIFICATIONMECHANICAL Format 66.3;n x 39.4 n x 1.26in (including ttame) 1685mm x 1000mm x 32mm) Willi" 41.21bs (18.7 kg) Front Cover 0.13 in (3.2mm) thermally pre -stressed glass with anti -reflection technology Back Cover Compos to filmM- Ffame Brack anodized aluminum Cell 6 x 20 monocrystalline Q.ANTUM solar half -cells ro Junction box 2.76-3.35 n x 1.97-2.76in x 0.51-0.83 n 70-85mm x 50-70rrm x 13-21 mm), decentralized, IP67 Cable 4mm' Solar cable; (+)x43,3in(IICOmm),(-)t43.3in0100mm) 1 Flx•w«.p n4, 1 a I Connector Multi -Contact MCA, IP68 ELECTRICAL CHARACTERISTICS H aae• au..rT Inwnaea POWER CLASS 300 305 310 315 320 MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS, STC' (POWER TOLERANCE 5IN /-0 W) Power A( MPP P.,e (W) 300 305 310 315 320 Short c)rcult Currem I„ IA] 9.72 9.78 9.83 9.89 9.94 EopenCircuitVoltageV. IV] 39.48 39.75 40.02 40.29 40.56 Curren! at MPP I[A) 9.25 9.31 9,36 9.41 9.47 Voltage at MPP V,., IV] 32.43 32.78 33.12 33.46 33.00 Efficiency' 11 l l 217.8 z18.4 218.7 219.0 MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS, NMOT' Pd1111 al MPP P.. IW1 224 1 227.8 231.6 235.3 239.1 E Short Circuit Curro it I„ IA) 7.83 7.88 7.92 7.97 8.01 open clrcun raNage V„ IV] 37.15 37.40 37.66 37.91 38.17 Current n MPP I[A] 7.28 7.32 7.37 7.41 7.45 Wilhite at MPPV.,« IV] 30.78 31.11 31.44 31.76 32.08 Measurement tolerances P«„3%;1,•,Vas5A dSTC, 1000fiVi21 AM 1.543accerdlna to IEC 60904-3 '800111 NMOT, spectrum AM i 5C 0 CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE 0'• At least 98%atnominal power during first yeasT-"- Thereafter max. 0.54% degradation per year i At least 93 1 % M nominal power up to 10 years. 5 Atleast65 % of nominal power up to 25 years. o r s•-"-"------ Alldata within measurernert tolerances, N _' ' ! j Full warranties in accordance with the warranty ! r terms of the Q CELLS sales organizattor of your respective 8 ccuntry. w ! ! -r ' •• w w w w See MaA/UNCE IWAm9 e • a 1D ' Typical module performance under low irradiance conditions in Yp comparisontc STC conditions (25°C, 1000Whn'1. TEMPERATURE COEFFICIENTS Temperature Coefficient of I„ a [%/Kl +0.04 Temperature Coefficient W Ya_ P [%/Kl -0.28 Temperature Coefficient of P.,, y [%/K] -0.37 Normal Operating Module Temperature NMOT [IF] 109 m5.4 (43 f3«C) PROPERTIES1 DESIGN Maximum system Voltage Vs,,, (V] 1000 (IEC) ! 1000 (UU Satiny Class II Maximum Series Fast Rating (A DCl 20 Fire Rating C (IEC) / TYPE 1 (UL) Max Design Load, Push Jr Poll (Ii (les/fl 1 75 (3600 Pa) 155 (2667 Pa) hrmNtad module tomperaluire -40°F up to +185°F on continuous" 1-40°C up 1o+85°C) Max Test Lead, Posh/Pull (ULF IIYe1N'1 113 (5400Pal 184 (4000Pa) ' See Installation manual OILIALIFICATIONS AND CERTIFICATES PACKAGING INFORMATION UL 170. 9; VIDEMaPty Tsted; CE-comp!lant; Number n Mpddes Per Pellet 3P IEC 61215:2016; IEC 61730:2016, App.'icatlon class A Number of Pallets par 53' Trader 30 pvE /e ( ores Number of Pallets pru 40' High Cube Cantinri 26 C v Pallet Oifeensions (L x W x H) 69+3 in x 45 3 in x 46.9In 1.cUS1760mmx 1150mm x 7190mm) Pallet Weight 1415lbs (642 kg) NOTE! Instal ation instructions must be followed. See the instailst!on and operating manual a contact our technical service department for further information on approved installation and use of thisproduct. Hassle 2 CELLS AmericaInc. 300 SPectnm Center Drive, Suite 1250, Irvine, CA 92618, USA I TEL 4.1 949 748 59 96 1 EAtAII inquiry®cs.or cans. cam ! WED www.q-ce!Is.us Data Sheet Enphase Microinverters Region. AMERICAS Enphase IQ 7 and IQ 7+ Microinverters The high-powered smart grid -ready Enphase IQ 7 Micro"' and Enphase IQ 7+ Micro'" dramatically simplify the installation process while achieving the highest system efficiency. Part of the Enphase IQ System, the IQ 7 and IQ 7+ Microinverters integrate with the Enphase IQ Envoy', Enphase IQ Battery"", and the Enphase Enlighten"" monitoring and analysis software. IQ Series Microinverters extend the reliability standards set forth by previous generations and undergo over a million hours of power -on testing, enabling Enphase to provide an industry -leading warranty of up to 25 years. Easy to Install Lightweight and simple Faster installation with improved, lighter two -wire cabling Built-in rapid shutdown compliant (NEC 2014 & 2017) Productive and Reliable Optimized for high powered 60-cell and 72-cell* modules More than a million hours of testing Class II double -insulated enclosure UL listed Smart Grid Ready Complies with advanced grid support, voltage and frequency ride -through requirements Remotely updates to respond to changing grid requirements Configurable for varying grid profiles Meets CA Rule 21 (UL 1741-SA) The IQ 7+ Micro is required to support 72-cell modules. To learn more about Enphase offerings, visit enphase.com EN PHAS E. Enphase IQ 7 and IQ 7+ Microinverters INPUT DATA (DC) IQ7-60-2-US / IQ7-60-B-US IQ7PLUS-72-2-US / IQ7PLUS-72-B-US Commonly used module pairings' 235 W - T5DW+ 235 W 440 W + Module compatibility 60-cell PV modules only 60-cell and 72-cell PV modules Maximum input DC voltage 48 V 60 V Peak power tracking voltage 27 V - 37 V 27 V - 45 V Operating range 16 V - 48 V 16 V - 60 V Min/ Max start voltage 22 V / 48 V 22 V / 60 V Max DC short circuit current (module Isc) 15 A 15 A Overvoltage class DC port II II DC port backfeed current 0 A 0 A PV array configuration 1 x 1 ungrounded array; No additional DC side protection required; AC side protection requires max 20A per branch circuit OUTPUT DATA (AC) IQ 7 Microinverter IQ 7+ Microinverter Peak output power 250 VA 295 VA Maximum continuous output power 240 VA 290 VA Nominal ( L-L) voltage/range2 240 V / 208 V / 240 V / 208 V / 211- 264 V 183-229 V 211-264 V 183-229 V Maximum continuous output current 1.0 A (240 V) 1.15 A (208 V) 1.21 A (240 V) 1.39 A (208 V) Nominal frequency 60 Hz 60 Hz Extended frequency range 47 - 68 Hz 47 - 68 Hz AC short circuit fault current over 3 cycles 5.8 Arms 5.8 Arms Maximum units per 20 A (L-L) branch circuit' 16 (240 VAC) 13 (208 VAC) 13 (240 VAC) 11 (208 VAC) Overvo tage class AC port III III AC port backfeed current 0 A 0 A Power factor setting 1.0 1.0 Power factor (adjustable) 0.7 leading ... 0.7 lagging 0.7 leading ... 0.7 lagging EFFICIENCY @240 V @208 V @240 V @208 V Peak CEC efficiency 97.6 % 97.6 % 97.5 % 97.3 % CEC weighted efficiency 97.0 % 97.0 % 97.0 io 97.0 %, MECHANICAL DATA Ambient temperature range 400C to +65°C Relative humidity range 4%to 100% (condensing) Connector type (IQ7-60-2-US & IQ7PLUS 72-2-US) MC4 (or Amphenol H4 UTX with additional Q-DCC-5 adapter) Connector type (IQ7-60-B-US & IQ7PLUS-72-B-US) Friends PV2 (MC4 intermateable). Adaptors for modules with MC4 or UTX connectors: PV2 to MC4: order ECA-S20-S22 PV2 to UTX: order ECA-S20-S25 Dimensions ( WxHxD) 212 mm x 175 mm x 30.2 mm (without bracket) Weight 1.08 kg (2.38 Ibs) Cooling Natural convection - No fans Approved for wet locations Yes Pollution degree Enclosure Environmental category / UV exposure rating PD3 Class II double -insulated, corrosion resistant polymeric enclosure NEMA Type 6 / outdoor FEATURES Communication Power Line Communication (PLC) Monitoring Enlighten Manager and MyEnlighten monitoring options. Both options require installation of an Enphase IQ Envoy. Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load -break disconnect required by NEC 690. Compliance CA Rule 21 (UL 1741-SA) UL 62109-1, UL1741/IEEE1547, FCC Part 15 Class B, ICES-0003 Class B, CAN/ CSA-C22.2 NO. 107.1-01 This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and NEC- 2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC conductors, when installed according manufacturer's instructions. 1. No enforced DC/AC ratio. See the compatibility calculator at hnps://ennhase.com/en-us/support/module-compatibility_. 2. Nominal voltage range can be extended beyond nominal if required by the utility. 3. Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area. To learn more about Enphase offerings, visit enphase.com v EN PHAS E. tD 2018 Enphase Energy. All rights reserveo. All trademarks or branos used are the property of Enphase Energy, Inc 2018- 05-24 Cut Sheet - Rock-It-4.0-Coupling 1. Installation to be completed in accordance with manufacturer's written specifications and installation instructions.. 2. See spec sheet or contact manufacturer for detailed material, finishes, and configuration options. 3. Contact manufacturer for detailed layout. 4. Do not scale drawings. 5. Subject to change without notice. 7.00in 177.80mm i 2.02in 51.38mm IT i 32mm 3.17in 80.54mm 2.14in r54.37mm awl 35mm 2.34in d 59.36mm; i 40mm SNOAUINE 4741 W Polk Stree Ste. 4UARDS'' 'XOFasten Solar' Phoenix, AZ 85043 Toll Free Phone 1.888.766.4273 Toll Free Phone 1.877.859.3947 Material: See Spec SheetTollFreeFax1.888.766.9994 Toll Free Fax 1,888,766.9994 Scale: 1:4 6/28/2017 ASG: - EFS: x Cut Sheet - Rock-It-4.0-Hybrid Coupling 1. Installation to be completed in accordance with manufacturer's written specifications and installation instructions. 2. See spec sheet or contact manufacturer for detailed material, finishes, and configuration options. 3. Contact manufacturer. for detailed layout. 4. Do not scale drawings. 5. Subject to change without notice. 3.16in 0 ® [80.29 m m] 7.00in 177.80mm I 2.02in 151 .38mm s 32mm 2.14in L54.37mm_ a:- 35mm I 5.00in 127mm] 2.34in 159.36mmi i 40mm WSNXGUARDS';i LE 4741 W Polk Street Ste. 4oFastenSolarz' Phoenix, AZ 85043 Toll Free Phone 1.888.766.4273 Toll Free Phone 1.877.859.3947 Material: See Spec Sheet Toll Free Fax 1.888.766.9994 Toll Free Fax 1.888.766.9994 Scale; 1:1 6/28l2017 ASG: - EFS: x pOCK-IT SYSTEM`4.O RAIL -FREE RACKING UTILIzes ECOFasTen SOLars PaTenTeD TeCHnOLOGt A aEcoFasten Solar La IU4>EcoFas 0 Committed b Document Date: 9.8.2017 Contents Pg. 1 Assets of Design Features System Components Pg• 2 Rock -It 4.0 Mount Assembly Rock -It 4.0 Coupling Assembly Pg• 3 Rock -It 4.0 Hybrid Mount Assembly Rock -It Clip SS Assembly Rock -It Clip 2.0 Assembly Pg. 4 Array Layout GreenFasten Flashing Install Pg• 5 Rock -It System 4.0 Install Pg. 6 Ground Lug Install Pg• 7 Rock -It Clip SS Install Rock -It Clip 2.0 Install Pg. 8 -12 Standoff Spacing Tables Snow Load 0-20 psf Snow Load 21-30 psf Snow Load 31-40 psf Snow Load 41-50 psf Snow Load 51-60 psf Pg. 13 Grounding Information Bonding Assembly and Bonding Path Pg. 14 Thermal Expansion and Bonding Bracket Spacing Staggered Layout Cantilever Pg. 15-16 System Specifications Evaluated, Compatible Modules ROCK -IT SY STeM 4.0 Designed with the Installer In mind. EcoFasten Solar specializes in solar roof attachments that are fast and easy to Install, straightforward, secure and cost-effective. EcoFasten offers a wide variety of standard products as well as custom solutions, for a one -stop source for all of your rooftop anchoring needs. Products are rigorously tested and approved above and beyond industry standards in-house and by third party agencies. EcoFasten's patented conical sealing system has been In service in the snow guard and solar industries for two decades. FeaTu res New and improved design Fastest, easiest to level system on the market Integrated electrical bonding SIMPLE- only 4 components North -South adjustability Only one tool required (1/2"deep well socket) Vertical adjustment of 3"-40 SYSTem comPonenTS* - reouireD Opp yv ROCK -IT SLIDe ROCK -IT 4.0 ROCK -IT 4.0 COLIPLInG 4' For COMP sHInGLe MounT & LoaD BeannG FOOT8' For TILe SYSTem componenTS* - oPTIonaL ROCK -IT CLIP SS ReFer TO PG. 6) ROCK -IT 4.0 H jBrID mounT ReFer TO PG. 5) ROCK -IT CLIP 2.0 ReFer TO PG. 6) ROCK -IT 4.0 Array SKIrT A ItC,EcolFasten Solar® EcoFasten Solar products are protected by the following U.S. Patents: 8,151,522 8,153,700 8,181,398 8,166,713 8,1446,299 ROCK -IT 4.0 6,209,914 8,245,454 8,272,174 8,225,557 9,010,038 Ariag 5K I rT 9,134,040 9,175,478 9,212,833 EnD Caps cenD caws come Pre-n, STaL.Leo on EaST eno of sKirT secrionsl Components for use with 32mm modules are available as special order. Components for use with 32mm modules are labeled as such on system packaging. Please refer to evaluated, compatible modules grid on page 15 to identify system compatible 32mm modules. www.ecofastensolar.com info@ecofastensolar.com 877-859-3947 1 IV-0- o1j) ROCK -IT 4.0 MOl. nT ASseM BLS NOTe: ITeMS 1-7 SHIP assemBLeD 1 5/16"-18 x 1.75" Hex Serrated Flange Bolt 300 Series SS 2 Rock -It 4.0 Mid -Clamp 6000 Series AL 3 Rock -It 4.0 Shelf 6000 Series AL 4 Flange Level Nut 300 Series SS 5 Rock -It 4.0 Tie Plate 6000 Series AL 6 Rock -It Pedestal 6000 Series AL 7 5/16"-18 x 3/8" Hex Serrated Flange Bolt 300 Series SS 8 3/8" ID Star Washer 300 Series SS 9 3/8"-16 x 3" Hex Tap Bolt 300 Series SS ROCK -IT SLIDes are accePTaBLe BraCKeTs For Use WITH ROCK -IT 4.0 (SOLD separaTeLY ) ROCK -IT 4.0 COUPLING asse i1BLY NOTe: ITems 1-3 SHIP assemBLeD 1 5/16"-18 x 1.75" Hex Serrated Flange Bolt 300 Series SS 2 Rock -It 4.0 Coupling Mid -Clamp 6000 Series AL 3 Rock -It 4.0 Coupling Shelf 6000 Series AL 4 Rock -It Load Bearing Foot Clip 5 Rock -It Load Bearing Foot Base I www.ecofastensolar.com info@ecofastensolar.com 877-859-3947 2 ROCK -IT 4.0 HYBRID MOI. nT ASseMBL9 NOTe: ITems 1-lo SHIP assemBLeD ROCK -IT CLIP SS AssemBL-Y NO,Te: _0MS 1-3 SHIP assemBLeD 1 Stainless Steel Carriage Bolt - .313-18X.75 2 Rock -It Clip SS 3 Stainless Steel Flange nut .313-18 2 1 Rock -It 4.0 Shelf 6000 Series AL 2 Rock -It 4.0 Coupling Mid -Clamp 6000 Series AL 3 Rock -It 4.0 Coupling Tie Plate6000 Series AL 4 Flange Level Nut 300 Series SS 5 Rock -It Pedestal 6000 Series AL 6 Rock -It Slide 6000 Series AL 7 3/8"-16 x 3" Hex Tap Bolt 300 Series SS 8 3/8" ID Star Washer 300 Series S 9 5/16"-18 x 3/8" Hex Serrated Flange Bolt 300 Series SS 10 5/16"-18 x 1.5" Hex Serrated Flange Bolt 300 Series 55 ROCK -IT CLIP 2.0 ASseMBLY NOTe: ITemS 1-3 SHIP assemBLeD 1 Rock -It Clip 2.0 I 2 Stainless Steel Flange nut .313-18 3 Bolt .3125-18xlx1-5 www.ecofastensolar.com info@ecofastensolar.com 877-859-3947 3 Arra-Y LayouT Find the required structural attachment points. Mark these using a vertical (N-S) chalk line on the center of the rafters. Spacing may vary depending upon project specific structural requirements; i.e. high snow and wind load areas may require lesser bracket spacing in the E-W axis vs. the maximum spacing. Max spacing is 48"for portrait orientation and 72"for landscape orientation. Consult project layout diagram for project specific bracket spacing on the roof. Install Rock -It Mounts to predetermined mount spacing. The Rock -It Array Skirt sections are the width of a typical 60 cell module — use the Rock -It Array Skirt as a guide to lay out module placement. Note: The distance between the rows of mounts is calculated by the module dimension N-S plus 1 3/8" 35mm). Lag screw should be installed as close to center of exposed shingle as possible. The minimum distance between the lag screw and the edge of the shingle is 1 /2". GreenFaSTen` FL_aSHinG InSTaLL vertical lines to mark the installation position for each GreenFasten flashing. 2 Drill a pilot hole (1/4' diameter) fort he lag bolt. BackfiII with sealant. EcoFasten Solar recommends an EPDM mastic. 3 Insert the Flashing so the top part is under the next row of shingles and pushed far enough up slope to prevent water infiltration through vertical joint in shingles. The leading edge of flashing must butt against upper row of nails to prevent turning when torqued. 4 Line up pilot hole with GreenFasten flashing hole. Insert the lag bolt through the EPDM bonded washer, the Rock -It slide, the gasketed hole in the flashing and into the rafter. Torque: The range is between 100-140 torque inch -pounds depending on the type of wood and time of year. The visual indicator for proper torque is when the EPDM on the underside ofthe bonded washer begins to push out the sides as the washer compresses. If using an impact wrench to install the fasteners be careful not to over torque the fastener. You may need to stop and use a ratchet to finish the install. The Engineer of Record shall check capacity of rafter to support lag screw loading. www.ecofastensolar.com info@ecofastensolar.com 877-859-3947 4 ROCK -IT SYSTeM 4.O inSTaLL liiiw 7 Fig. A I Install EcoFasten Solar Flashing with Rock -It Mounts Follow ECOFastrvt SOW Install Mstnxtlom forflashing andbracket install (GreenFasten shownabove). Optimum vertical distance between lag belts Is 13/8* plus module dimension Set mounts on eave most row so that the RodNt Pedestal Is on the South end of Rock-tt Silos. Set mounts on al I upper rows so that the Rock -It Pedestal Is on the North end of Rode -It Slide. 2 Install Rock -It Array Skirt onto Eave MountsSlideRock -It Array Skirt Into front channel on Rock -It Shelf. Array Skirt End Caps are pre -Installed on the East end of each skirt section, and are used to couple the skirt sections where needed (see Fig. A). Tighten Mid -Clamp bolt, damping Rock-4t Array Skirt to mount. Torque to 200 inabs. (130 in-lbs. when installing with 32mm modules). Install Rock -It Couplings (when joining 4 panels with a Coupling, the use of a load bearing foot Is required) 3-4 Prior to mounting on the roof, snap Load Bearing Foot Into the bottom ofRock -it Coupling If required. Each Load Bearing Foot is set to same height as the Rock -It Mounts - adjust accordingly) On eave row only, slide Rock -It Array Skirt onto Rock -It Coupling Shelf. Torque to specified value - NOTE: If a coupling lands on a rafter, the Hybrid Mount' should be used In place of the Rock It Coupling (refer to image 3a). Hybrid Mount can be made In the Held by assembling a coupling to a mount pedestal, or by purchasing separately. Align and Straighten First Row of the Rock -It System with Rock -It Array Skirt5UseNorth -South adjustment of the Rock -It Pedestal to straighten Rock4t Array Skirt and align module with Array Skirt. Torque screw on side of Rock-ft Pedestal to 150 In-lbs to secure It to the Rocket Slide. Adjust Flange Level Nut to level the system (optional - can be leveled during or after Installation). 6_(] Install 1st Row of PV Modules 77 Slide upslope Rock -It Mounts down to engage top offirst module. Install Rock -It Couplings on the upslope side of 1st row ofpanels. Torque 2nd row of Mld{lamps on Rock4t Mounts and Rode -ItCouplings to spedfied value. Install balance of PV modules, ensuring that the Rock -It Pedestals are in the appropriate position, then torque Mid -Clamps to secure modules. 10 Level the Rock -It System When assembly is complete, level the entire system by adjusting Flange Level Nuts (Flange Level Nuts have notorque value). Height between roof surface and underside of modules should be 3•or less, when installed with Type 2 modules. INSTALLATION NOTE: Modules should be Installed so that the junction box is installed upslope, away from the leading edge of the array. www.ecofastensolar.com info@ecofastensolar.com 877-859-3947 GrounDinG LUG InSTaLL 1 2 3 Necessary Components: One of the following ground lugs (or any UL 2703 compliant ground lug): Burndy CL50-1TN Ground Lug (UL 2703 - E351343 / UL 467 - E9999) ILSCO SGB-4 Ground Lug (UL 2703 - E354420 / UL 467 - E34440) ILSCO GBL-4DBT (UL 2703 - E354420 / UL 467 - E34440) ILSCO GBL-4DBTH (UL 2703 - E354420 / UL 467 - E34440) ILSCO GBL-4SS (UL 2703 - E354420 / UL 467 - E34440) Note: Drill and deburr hole in Ground Lug prior to installation 14 AWG - 4 AWG Copper Ground Wire* Torque Values: 8-32 x 0.5" Serrated Flange Head Bolt (300 Series SS) 14-10 AWG= 20 in-Ibs. 8-32 Serrated Flange Nut (300 Series SS) 8 AWG- 25 in-lbs. 11 /32" and 1 /4" wrenches or ratchets/sockets 6-4 AWG= 35 in-Ibs. 1 Insert the flange bolt into the module ground hole. Place Star Washer over bolt. Place ground lug over the bolt and Star Washer, and turn to desired orientation. 2 Install Flange Nut. 3 Tighten Flange Nut/Bolt. 4 Place wire in Ground Lug channel and tighten set screw to complete assembly. Wire should be sized in accordance with the National Electrical Code, NFPA 70, Section 690.45, and a minimum of 1/4"clearance required between bare copper wire and aluminum. F. Drill hole per grounding lug manufacturers specifications in the upslope part of Rock -It Coupling for attaching grounding lug. Note: Deburr hole in Ground Lug and Rock -It Coupling prior to installation. www.ecofastensolar.com info@ecofastensolar.com 877-859-3947 6 ROCK -IT CLIP SS inSTaLL 1 Locate all parts k(tV ek Mokogirg Locatbns Min IT i . I nctor. Ao Locate the Rock -It Clip SS, micro-inverter/power optimizer, and the section of the module frame in which you will be mounting the micro-inverter/power optimizer. See fig. A for acceptable mounting locations. Install the Rock -It Clip SS Slide the Rock -It Clip SS onto the lip of the module frame. Slide the micro-inverter/power optimizer into the opposite lip ofthe Rock -It Clip SS. Tighten the bolt to 150 in -lb minumum to clamp the Rock -It Clip SS to the module frame and the micro-inverter/power optimizer to the Rock -It Clip SS. Ensure that the lip on the clip is tight against the frame and that the micro-inverter/power optimizer flange istightagainsttheclipflangetoavoidrotationduringtightening. ROCK -IT CLIP 2.O InSTaLL 1 Locate all parts Locate the Rock -It Clip 2.0, micro-inverter/power optimizer, and the section of the module frame in which youwillbemountingthemicro-inverter/power optimizer. 2 Install the Rock -It Clip 2.0 (See below detail) Slide the Rock -It Clip 2.0 onto the lip of the micro-inverter/power optimizer. Slide the micro-inverter/power optimizer into the opposite lip of the module frame. Tighten the bolt to 150 in -lb to clamp the Rock -It Clip 2.0 to the module frame and the micro-inverter/poweroptimizertotheRock -It Clip 2.0. Ensure that the lip on the clip is tight against the frame and that the micro-inverter/power optimizer flange is tight against the clip flange to avoid rotation during tightening. www.ecofastensolar.com info@ecofastensolar.com 877-859-3947 Snow Load 0-20 psf Modules in Landscape Wind Speed Exposure Category 2:12 < Roof Pitch < 6:12 7:12 < Roof Pitch < 12:12 ASCE 7-05 ASCE 7-10 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 B 159 93 59 85 mph 110 mph C 114 67 42 88 88 91D965635 74 74 B 146 85 54 98 80 8090mph115mphC1046138 D 88 51 32 83 68 68 100 mph 125 mph B C 123 88 72 51 45 32 95 68 95 6883 D 74 43 27 70 57 57 110 mph 140 mph B C 98 70 57 41 36 26 93 66 76 54 76 54 D 59 34 22 56 46 46 120 mph 150 mph B C 85 61 50 36 31 22 81 58 66 47 66 47 D 51 30 19 49 40 40 oa. spacing Governed by Snow Load 1.) Values in above table represent the maximum allowable spacing in inches for pullout forces only on EcoFasten Solar standoff, however the designer must round down to meet appropriate rafter spacing 2.) Maximum allowed spacing approved by EcoFasten Solar is 72" 3.) Maximum allowed standoff capcity = 547if (per testing results) 4.) Includes additional factor of safety of 1.5 for lag pullout capacity 5.) Values based on a maximum module width of 40" 6.) Based on Risk Category II (ASCE 7-10) structures less than 30 feet in height 7.) All adjustment factors are set to 1. No site specific engineering is included in this table Snow Load 0-20 psf Wind Speed Exposure Category 2:12 < Roof Pitch 6:12 7:12 < Roof Pitch 12:12 ASCE 7-06 ASCE 7-10 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 B 91 53 33 61 50 5085mph110mphC653824 D 55 32 20 52 42 42 B 83 49 30 56 46 4690mph115mphC593522 D 50 29 18 47 38 38 100 mph 125 mph B C 70 50 41 29 26 18 54 39 54 3947 D 42 26 15 40 32 32 B 56 33 20 53 43 43 110 mph 140 mph C 40 23 14 38 31 31 D 34 19 12 32 26 26 B 49 28 18 46 37 37 120 mph 150 mph C 35 20 12 33 27 27 D 29 17 10 28 22 22 Spacing Governed by Snow Load 1.) Values in above table represent the maximum allowable spacing in inches for pullout forces only on EcoFasten Solar standoff 2.) Maximum allowed spacing approved by EcoFasten Solar is 48" 3.) Maximum allowed standoff capcity = 547# (per testing results) 4.) Includes additional factor of safety of 1.5 for lag pullout capacity 5.) Values based on a maximum module length of 70" 6.) Based on Risk Category II (ASCE 7-10) structures less than 30 feet in helght 7.) All adjustment factors are set to 1. No site specific engineering is included in this table www.ecofastensolar.com info@ecofastensolar.com 877-859-3947 Snow Load 21-30 psf Modules in Landscape Wind Speed ASCE 7-05 ASCE 7-10 Exposure Cate or 2:12 < Roof Pitch < 6.12 7:12 < Roof Pitch < 12:12 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 B 93 59 85 mph 110 mph C 67 42 D 96 56 35 B 85 54 90 mph 115 mph C 104 61 38 D 88 51 32 100 mph 125 mph B C 72 51 45 3288 110 mph 120 mph 140 mph 150 mph D B C D B C 74 98 70 59 85 61 43 57 41 34 50 36 27 57 57 36 26 66 54 54 22 56 46 46 31 66 66 22 58 47 47 D 51 30 19 49 40 40 Spacing Governed by Snow Load 1.) Values In above table represent the maximum allowable spacing in inches for pullout forces only on EcoFasten Solar standoff, however the designer must round down to meet appropriate rafter spacing 2.) Maximum allowed spacing approved by EcoFasten Solar is 72" 3.) Maximum allowed standoff cepcity - 547# (per testing results) 4.) Includes additional factor of safety of 1.5 for lag pullout capacity 5.) Values based on a maximum module width of 40" 6.) Based on Risk Category II (ASCE 7-10) structures less than 30 feet in height 7.) All adjustment factors are set to 1. No site specific engineering Is Included in this table Snow Load 21-30 psf 1V uleb. Spacing Governed by Snow Load 1.) Values in above table represent the maximum allowable spacing in inches for pullout forces only on EcoFasten Solar standoff 2.) Maximum allowed spacing approved by EcoFasten Solar is 48" 3.) Maximum allowed standoff capclty = 547# (per testing results) 4.) Includes additional factor of safety of 1.5 for lag pullout capacity 5.) Values based on a maximum module length of 70" 6.) Based on Risk Category II (ASCE 7-10) structures less than 30 feet in height 7.) All adjustment factors are set to 1. No site specific engineering is included in this table www.ecofastensolar.com info@ecofastensolar.com 877-859-3947 Snow Load 31-40 psf Modules In Landscape Wind Speed Exposure 2:12 < Roof Pitch Category Zone 1 Zone 2 6:12 7:12 < Roof Pitch < 12:12 ASCE 7-05 ASCE 7-10 Zone 3 Zone 1 Zone 2 Zone 3 B 59 85 mph 110 mph C 67 42 D 56 35 B 54 90 mph 115 mph C 61 38 D 51 32 B 45 100 mph 125 mph C 51 32 D 74 43 27 B 57 36 110 mph 140 mph C 70 41 26 D 59 34 22 46 46 B 50 31 120 mph 150 mph C 61 36 22 47 47 D 51 30 19 49 40 40 Notes: Spacing Governed by Snow Load 1.) Values in above table represent the maximum allowable spacing in inches for pullout forces only on EcoFasten Solar standoff, however the designer must round down to meet appropriate rafter spacing 2.) Maximum allowed spacing approved by EcoFasten Solar is 72" 3.) Maximum allowed standoff capcity = 547# (per testing results) 4.) Includes additional factor of safety of 1.5 for lag pullout capacity 5.) Values based on a maximum module width of 40" 6.) Based on Risk Category II (ASCE 7-10) structures less than 30 feet in height 7.) All adjustment factors are set to 1. No site specific engineering is included in this table Snow Load 31-40 psf Notes: Spacing Governed by Snow Load 1.) Values in above table represent the maximum allowable spacing in inches for pullout forces only on EcoFasten Solar standoff 2.) Maximum allowed spacing approved by EcoFasten Solar Is 48" 3.) Maximum allowed standoff capclty = 547# (per testing results) 4.) Includes additional factor of safety of 1.5 for lag pullout capacity 5.) Values based on a maximum module length of 70" 6.) Based on Risk Category II (ASCE 7-10) structures less than 30 feet in height 7.) All adjustment factors are set to 1. No site specific engineering is included in this table www,ecofastensolar.com info@ecofastensolar.com 877-859-3947 10 Snow Load 41-50 psf Modules in Landscape Wind Speed Exposure 2:12 < Roof Pitch Cate o Zone 1 Zone 2 6:12 7:12 < Roof Pitch < 12:12 ASCE 7-05 JASCE 7-10 Zone 3 Zone 1 Zone 2 Zone 3 B 59 85 mph 110 mph C 42 D 56 35 B 54 90 mph 115 mph C 61 38 D 51 32 B 45 100 mph 125 mph C 51 32 D 43 27 B 57 36 110 mph 140 mph C 41 26 D 59 34 22 46 46 B 50 31 120 mph 150 mph C 61 36 22 47 47 D 51 30 19 49 40 40 Notes: Spacing Governed by Snow Load 1.) Values In above table represent the maximum allowable spacing in inches for pullout forces only on EcoFasten Solar standoff, however the designer must round down to meet appropriate rafter spacing 2.) Maximum allowed spacing approved by EcoFasten Solar Is 72" 3.) Maximum allowed standoff capcity = 547# (per testing results) 4.) Includes additional factor of safety of 1.5 for lag pullout capacity 5.) Values based on a maximum module width of 40" 6.) Based on Risk Category Il (ASCE 7-10) structures less than 30 feet in height 7.) All adjustment factors are set to 1. No site specific engineering is Included in this table Snow Load 41-50 psf Notes: Spacing Governed by Snow Load 1.) Values in above table represent the maximum allowable spacing In Inches for pullout forces only on EcoFasten Solar standoff 2.) Maximum allowed spacing approved by EcoFasten Solar is 48" 3.) Maximum allowed standoff capcity = 547# (per testing results) 4.) Includes additional factor of safety of 1.5 for lag pullout capacity 5.) Values based on a maximum module length of 70" 6.) Based on Risk Category 11 (ASCE 7-10) structures less than 30 feet in height 7.) All adjustment factors are set to 1. No site specific engineering is included in this table www.ecofastensolar.com info@ecofastensolar.com 877-859-3947 11 Snow Load 51-60 psf N()te5: Spacing Governed by Snow Load 1.) Values in above table represent the maximum allowable spacing in inches for pullout forces only on EcoFasten Solar standoff, however the designer must round down to meet appropriate rafter spacing 2.) Maximum allowed spacing approved by EcoFasten Solar Is 72" 3.) Maximum allowed standoff capcity = 547# (per testing results) 4.) Includes additional factor of safety of 1.5 for lag pullout capacity 5.) Values based on a maximum module width of 40" 6.) Based on Risk Category II (ASCE 7-10) structures less than 30 feet in height 7.) All adjustment factors are set to 1. No site specific engineering is Included in this table Snow Load 51-60 psf Notes: Spacing Governed by Snow Load 1.) Values in above table represent the maximum allowable spacing in inches for pullout forces only on EcoFasten Solar standoff 2.) Maximum allowed spacing approved by EcoFasten Solar is 48" 3.) Maximum allowed standoff capcity = 547# (per testing results) 4.) Includes additional factor of safety of 1.5 for lag pullout capacity 5.) Values based on a maximum module length of 70" 6.) Based on Risk Category 11 (ASCE 7-10) structures less than 30 feet in height 7.) All adjustment factors are set to 1. No site specific engineering is included in this table www.ecofastensolar.com info@ecofastensolar.com 877-859-3947 12 GrounDinG inFormaTion The rail -free Rock -It System may be used to mount and ground PV modules that comply with UL 1703, only when that specific module has been evaluated for mounting and grounding, in compliance with the included installation instructions. Note: Grounding lug must be visible to inspectors from the entire perimeter of the PV array. Multiple Use Grounding Pins Grounding pins within the Mid -Clamp are multiple use bonding/grounding devices. Modules will need to be adjusted if the Mid -Clamps are loosened to ensure there is `new"metal to pierce into upon retightening. Grounding Method Rock -It 4.0 Mount bonds N-5 rows of modules Rock -It 4.0 Coupling bonds E-W rows of modules Rock -It Array Skirt bonds E-W along the entire array when installed One Burndy CL50-ITN ground lug is required per PV array, limited to 300 modules placed in either portrait or landscape orientation. BonDInG AssemBLY ante BonDInG PATH Bond Path Grounding Lug trot (aaund",k n"2 Tt, t,aC} gexratrtc rarth QnuM Rock-R Cc -aping dock It Mount Rock -It Array Skirt Bond Path Gruu.tdrng Lug EQupmita GrountkngCondumr;EGG} S. ityw -I, rrot d Rock-k Coup'In& I Rock it Mum Rock-R Array Skvt Integrated Bonding Bood Path Ggroouppnnmding lug uacr IEGQCrow, ECard pntrary m mritrourM I Rod -it Couylirg I Rak-I; Want kak-It Way Skirt www.ecofastensolarcom info@ecofastensolar.com 877-859-3947 13 THermaL EXPansion anD BonDrG A thermal expansion gap Is required per each continuous 40' length of modules. Omit a coupling and leave a 2°gap in the Rock -It Array Skirt and also between the modules at that point. BracKeT sPacinG Portrait Orientation Landscape Orientation Bond Path Grounding Lug Equipment GroundEng ConctctoriEGQ gror.'.11ty to _rthJrd w Rock -it Coupling Rock -It Mount Rock It Array Skirt Maximum east/west bracket spacing is 48"OC. Max east/west bracket spacing is 72"OC. 32mm modules: Max east/west bracket spacing is 48" OC. Spacing may vary depending upon project specific structural requirements; i.e. high snow and wind load areas may require lesser spacing E-W than the maximum. sTaGGereD LaY ouT Staggered Mounting Points canTlLever anD oFFseT Rock -It Mount _Rock -It Coupling Cantilever: Maximum cantilever is 1/3 bracket spacing. For portrait orientation installations, check layout prior to installing. The array layout instructions in this installation manual offer a general overview of layout. Periodically, due to a variety of Offset: Offset from all roof edges depends on wind speed, snow actors (roof obstacles, shading, etc.) other layouts are required. loads, local fire and building codes per location www.ecofastensolar.com info@ecofastensolarcom 877-859-3947 14 ROCK -IT SY STeM 4.0 sysTem SPeclFicaTlons Max No. of Panels 300 Modules per ground lug Materials 300 Series Stainless, 6000 Series Aluminum Max System Voltage 1000VDC Coating Black Andodization/Mill Finish Class A Fire Rating With UL1703Type 1 Rated Lug Specifications Burndy CLSOATN Ground Lug Modules, see note below. UL Listing #KDER E9999) Leveling Range 3-4' Ground Wire 14 AWG- 4 AWG Copper Per above Lug spec Ground Wire Rock -It Slide Comp Range 3' Max Module Size 64.96"(1650mrn) x Rock -It Slide Tile 7' 39.05"(992mm) x 2'(50mm) Min/Max Roof Slope 1/2:12/12:12 Max Downforce/Uplift Rating 45 PSF Max Anchor Spacing (35rt1m/40mrn) 72' Rock -It Mount Load Rating S47lbs with Single S/16" Lag 3.0 Max Anchor Spacing (32mm) 48" Safety Factor Skirt Box QTY 6 units Slide Fastening Hole 5/16"diameter Mount Box CITY 12 units Module Cantilever Maximum cantilever Is 1/3 Rock -It Slide Box QTY 50 units bracket spacing Coupling Box CITY 12 units Warranty 20Year Material and Workman- ship Codes: National Electric Code, ANSI/NFPA 70, NEC 250, NEC 690, IRC, IBC Standards: UL 2703: First Edition, UL 1703 faii.v. Sa3a, *R KE.E-f15YSdar iaa As=r kf, D mot GGT.02-0016 MIUM104A ' [ oNioW510 Ot 1703 iA The EcoFasten Solar Rock -It System is a rooftop PV racking system consisting of 6000 Series Aluminum and 300 Series Stainless Steel components. The Rock -It System Includes the rack components but does not include the PV panels, Inverters or electrical components. The PV modules to be used with Rock -It shall be certified under UL 1703. The system shall be used on steep slope roofs mounted over a Class A fire rated roofing material and attached to the roof structure using 5/16" diameter, minimum 4' long 300 series Stainless Steel lag bolts with minimum thread embedment depth of 2 1/2" into the roof structure. Periodic re -inspection for loose components The system is subject to re -inspection as required by the PV module manufacturer or by the Authority Having Jurisdiction. Re -inspection, as required, should include evaluation of any loose components or loose fasteners. All loose components and fasteners should be secured In accordance with these instructions. The system should also be evaluated for any evidence of corrosion. Any corrosion should be removed. Any affected part should be cleaned or replaced in accordance with these instructions. PEcoFasten Solar www.ecofastensolar.com info@ecofastensolar.com 877-859-3947 15 FeaTures New and improved design North -South adjustability Fastest, easiest to level system on the market • Only one tool required (1 /2x deep well socket) Integrated electrical bonding Vertical adjustment of 3"-0• SIMPLE-only4 components EvaWaTeD, COMPaTIBLe MODULes Module Manufacturer Modd Type ("x" used to Indiwterarladetest Module Dimensions mm Module Dimensions in Downward Pressure Design Load (psf) UPwaniPressure Design Load (psf) Down-slo ripestp Load (psf) Maximum0amp Spacing (in) Tnna Solar TSM-xxx'X(115.06 1640 x 992 x 40 64.95"49.05"x1.57" 33.3 93.3 20 72CanadianSolarCS6P-xxxM 1638 x 922 x 4C 64.48")08.66"d.57" 33.3 33.3 20 72canaclanSolarC5SP•x"P 1638x982x40 64.5"x38.7'xl,57' 33.3 33.3 20 72 Jinko Solar KMx P-60 1650 x992 x40 649611139.05"d.57" 30P30 20 72JinkoSolarJKMxxW-60 1650 x 992 x 40 64.96"x39.05"d.57" 30 20 72JlnkoSolerJKMxxxPP-60 1650 x 992 x 40 64.96"x39.05"d.57" 30 20 72 Jinko Solar JKMxxxMM-60 1650 x 992 x 40 64.96"x39.05"xL57" 30 2C 72YISolarVL2xxP-29b 1650x99Dx40 6496"x38.97'd.57' 30 20 72 LG Eloetramcs LG300AOG89 1640 x 2000 x 35 U57"x39.37'd.38" 30 20 72LGEkxatronicsLG300NIK-64 1640 x 1000 K 40 6457" Y39.371157" 30 20 72AxitecSolarAC-xxx1J/15660S 1640x992x40 64.5"x39.06'k1.38" 30 2C 48RECX7MR(M•2xx-6MB 1640x992x35 64.56"x39.05"d,37' 30 20 72 Silfab SLA2xW 1650 x990 x 38 64.96"x38.37'd.49" 30 20 72SolariaPowerXrxxxR-BX 1621 x 1056 K 40 63.89"x41.53"d.57" 30 20 48Harmna -Q C ells' Cr.PRO G42xx 1670 x 1000 x 32 65.75"x39.37'd.25" 30 20 46Hanwha -q Cells' CLPRO G4 2xx 1670 x 2000 x 32 65.75"49.37'd.25" 30 30 20 72SurpremeGxB-3xx7 1670x997x40 65.75"49.25"x1.57" 30 30 20 46NECNEC-)MY6MB 1675x997x38 65.94"09.25"xl.5" 20 20 20 72RECREC-xxx6M8 1675 x 997 x 38 65.94"x3A25Nl.5" 30 30 20 40SolarworldSWxxxMonoBlack16751961x3365.95"07.8"x1.30" 20 20 20 72 Sdarwodd SW xKx Mono Black 1675 x 961 x33 65.95"x37.8"x1.30" 30 1 30 20 46 Hanwha Q- Cells 32mm modules to be used with special order Rock -It System components. Call for details. o EcoEasten Solar www.ecofastensolar.com info@ecofastensolar.com 877-859-3947 16 Cut Sheet - Rock-It-4.0-Mount 1. Installation to be completed in accordance with manufacturer's written specifications and installation instructions. 2. See spec sheet or contact manufacturer for detailed material, finishes, and configuration options. 3. Contact manufacturer for detailed layout. 4. Do not scale drawings. 5. Subject to change without notice. 3.17in 80.54mml 4 i - I G 2.02in 2.14in 51.38mm 1_54.37mrn i 32mm 2.50in 63.50mm j 35mm ALPINE SNCiVVGiUARDS'` ` " :, EcoI;asten Solar` Toll Free Phone 1.888.766.4273 Toll Free Phone 1,877,859.3947 Toll Free Fax 1.888.766.9994 Toll Free Fax 1.888.766.9994 2.34ii 59.36n i 40mm 4741 W Polk Street Ste. 4 Phoenix, AZ 85043 Material: See Spec Sheet Scale: 1:2 6/28/2017 ASG: - EFS: x Data Sheet Enphase Networking Enphase AC Combiner Box LISTED To learn more about Enphase offerings, visit enphase.com The Enphase AC Combiner box' with Enphase Envoy-S' consolidates interconnection equipment into a single enclosure and streamlines PV installations by providing a consistent, pre -wired solution for residential applications. Smart Includes Envoy-S for communication and control Flexible networking supports Wi-Fi, Ethernet, or cellular Simple Three pre -installed 20 A / 240 VAC circuit breakers Pre -configured revenue -grade metering available Reliable Durable NRTL-certified NEMA type 3R enclosure Five-year warranty ENPHASE Enphase AC Combiner Box MODEL NUMBERS XAMl-120-8 (880-00834) or AC Combiner with Enphase Envoy-S Metered" for integrated revenue grade PV productionXAM1-120 (880-00211) metering (ANSI C12.20 +/- 0.5%) and optional consumption monitoring (+/- 2.5%). . ACCESSORIES (order separately) Enphase Mobile Connect" Plug and play industrial grade cellular modem with five-year data plan for systems up to 60CELLMODEM-01 (3G) or microinverters. (Available in the US, Canada, Mexico, Puerto Rico, and the US Virgin Islands, CELLMODEM-03 (4G) where there Is adequate cellular service in the installation area.) Consumption Monitoring CT Split core current transformers enable whole home consumption metering (+/- 2.5%). CT-200-SPLIT ELECTRICAL SPECIFICATIONS Rating Solar branch circuit breakers Maximum system voltage Rated output current Rated Input current, each input Maximum fuse/circuit breaker rating (output) Continuous duty Three 2-pole 20 A / 240 VAC DIN rail -mounted breakers 240 VAC 48 A 16A 60 A Production Metering CT 200 A solid core pre -installed on solar busbar and wired to Envoy-S MECHANICAL DATA Dimensions (WxHxD) 38.0 x 38.7 x 20.3 cm (15.0" x 15.3" x 8.0') Weight 5.1 kg (11.2 Ibs) Ambient temperature range -40° C to +460 C (-40° to 1150 F) Cooling Vented, natural convection, plus heat shield Enclosure environmental rating Outdoor, NRTL-certified, NEMA type 3R, polycarbonate construction Altitude To 2000 meters (6,560 feet) Wire size: Follow local code requirements for conductor sizing. Model XAMI-120-B 14 to 6 AWG copper conductors for branch Inputs. 14 to 4 AWG copper conductors for combined output. Model XAM1-120 12 to 6 AWG copper conductors for branch inputs. 12 to 4 AWG copper conductors for combined output. INTERNET CONNECTION OPTIONS Integrated Wi-Fi Ethernet Cellular 802.11b/g/n 802.3, Cat5E (or Cat 6) UTP Ethernet cable - (not included) Optional, CELLMODEM-01 (313) or CELLMODEM-03 (4G)- (not included) COMPLIANCE Compliance, Combiner Box UL 1741 Compliance, Envoy-S UL 916 CAN/CSA C22.2 No. 61010 1 47 CFR, Part 15, Class B, ICES 003 IEC/EN 61010-1:2010, EN50065-1, EN61000-4-5, EN61000-6-1, EN61000-6-2 Metering: ANSI C12.20 accuracy class 0.5 To learn more about Enphase offerings, visit enphase.com r, : 1. 1 it are regisreied by their respective ow,)ec v E N P H A S E r S a eEcOPVROOF -MOUNT Basic Features Stamped Seamless Construction 18 Gauge Galvanized Steel a Powder Coated Surfaces Flashes Into the roof deck 3 Roof deck knockouts .5", .75", 1" 5 Centering dimples for entry/exit fittings or conduit 2 Position Ground lug installed Mounting Hardware Included ttr 4, Ilk Fuse holders and terminal blocks added In the field roust be UL listed or recognized and meet 600 VDC 30 AMP 110C for fuse holders, 600V 50 AMP 90C for rail mounded terminal bbcks and 600 V 175 AMP 90C for Power Distribution Slocim. Use Copper Wke Conductors. SolaDeck Model SD 0783 SolaDeck ULSO Type 311 Enclosures Available Models: Model SD 0783 - (3' fixed Din Rail) Model SD 0786 - (6' slotted Din Rai) SolaDeck UL 1741 Combiner/Enclosures Models SD 0783.41 and SD 078641 are labeled and ETL listed UL sTD 1741 according to the UL STD 1741 for photovoltaic combiner enclosures. Max Rated - 60OVDC, 120AMPS Model SD 0793-41 X Fixed Din Rail fastened using Nortock System Typical System Configuration 4- Din Rail Mounted Fuse Holders 60OVDC 30AMP 1- Power Distribution Block 60OVDC 175AMP 1- Bus Bar with UL lug Model SD 0786.41 6' Slotted Din Rail fastened using steel studs Typical System Configuration 4- Din Rail Mounted Fuse Holders 60OVDC 30 AMP 4- Din Rail Mounted Terminal Blocks Bus Bars with UL lug Corer is trimmed to allow conduit or fittings, base is center dimpled for fitting locations. Model SD 0783.41, wired wth Model SD 078641, wired Will DinRailmountedruseholders, Din Rail mounted fuse holders, busbarandpowerdistributionterminalblocksandWEbars. blockRSTC Enterprises, Inc . 2219 Heimstead Road . Eau Chare, WI 54703 For product information call 1(866) 367-7782