Loading...
103 Morrison Ave - BR18-004388 - REROOFM CITY OF SANFORD BUILDING & FIRE PREVENTION PERMIT APPLICATION Application No: 3 10 Documented Construction Value: $ 8828.20 Job Address: 103 Morrison Ave. Sanford FL 32773 Historic District: Yes No 0 Parcel ID: 12-20-30-511-0000-0820 Residential x Commercial Reroof Type of Work: New El Addition Alteration Repair Demo El 'Change of Use Move El Description of Work: Reroof - 25 sci GAF Timberline HD shingles Plan Review Contact Person: Qbbie Plvbon . Title: Phone: 407.696.7663 Fax: 407.695.7664 Email: staff rooftopservices.com Property Owner Information Name Bradford & Cristal Welborn Phone: Street: 201 Fryer Ln Resident of property? : City, State Zip: Sanford FI 32773 Contractor Information Name Roof Top Services of Central EL, Inc Phone; 407.696.7663 Street: 1150 Belle Ave., Suite #10 0 Fax: 407.695.7664 City, State Zip: Winter Springs, FL 32708 State License No.: CGC1326679 Arch itectlEngineer Information Name: Street: City, St, Zip: Bonding Company: Address: Phone: Fax: E- mail: Mortgage Lender: Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT .WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE. OF COMMENCEMENT. Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: 51h Edition (2014) Florida Building Code Revised: June 30, 2015 Permit Application <0 150 NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property ofthe requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal. The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value, credit will be applied to your permit fees when the permit is issued. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Pri 10 -16 - Zvi g nature of Owner/Agent Date P2t b 0410 IF PHYLLIS I. GIBSON MY COMMISSION #GG113127 EXPIRES: OCT 02, 2021 Bonded through 1st State Insurance 40/ W,, Signature of r.'ontractor/Agent Date Kristal A. Winaate Print Contractor/Agent's Name Sl- AH PLYBON Signatur tfAq , j&,SION # GG 102Me September ': 2021EXPIRE Q,, Bonded Thr i N 'arv' '` d rwriterspWc, u..lic u e Owner/ Agent is e-rsonallyKnown to Me or Contractor/Agent is x Personally Known to Me or Produced ID Type of ID Produced ID Type of ID BELOW IS FOR OFFICE USE ONLY Permits Required: Building Electrical Mechanical Plumbing Gas Roof Construction Type: Total Sq Ft of Bldg: Occupancy Use: Min. Occupancy Load: New Construction: Electric - # of Amps Fire Sprinkler Permit: Yes No APPROVALS: ZONING: ENGINEERING: COMMENTS: of Heads UTILITIES: FIRE: Flood Zone: of Stories: Plumbing - # of Fixtures Fire Alarm Permit: Yes No WASTE WATER: BUILDING: Revised: June 30, 2015 Permit Application Grant Maloy, Clerk Of The Circuit Court & Comptroller Seminole County, FLInst #2018124466 Book:9241 Page:240; (1 PAGES) RCD: 10/30/2018 1:34:21 PM REC; FEE $10.00 THIS INSTRUMENT PREPARED BY: Name: Kristal A. Wingate Address: 1150 Belle Ave., Suite #1060 Winter Springs, FL 32708-2962 Permit Number: Parcel ID Number. 12-20-30-511-0000-0820 The undersigned hereby gives notice that improvement will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement. 1. DESCRIPTION OF PROPERTY: (Legal description of the property and street address if available) Lot 82 Monroe Meadows PB 46 PGS 16 & 17 03 Morrison Ave., Sanford, FL 32773 2. GENERAL DESCRIPTION OF IMPROVEMENT: Reroof 3. OWNER INFORMATION OR LESSEE INFORMATION IF THE LESSEE CONTRACTED FOR THE IMPROVEMENT: Name and address: Bradford & Cristal Welborn, 201 Fryer Ln., Sanford, FL 32773 Interest in property: Property Owner Fee Simple Title Holder (if other than owner listed above) Name: Address: 4. CONTRACTOR: Name: Roof Top Services of Central Florida, Inc. Phone Number. (407) 696-7663 Address: 1150 Belle Avenue, Suite #1060, Winter Springs FL 32708-2962 5. SURETY (If applicable, a copy of the payment bond is attached): Name: Address: Amount of Bond: 6. LENDER: Address: Phone Number: 7. Persons within the State of Florida Designated by Owner upon whom notice or other documents may be served as provided by Section 713.13(1)(a)7., Florida Statutes. Name: Phone Number: Address: B.. In addition, Owner designates of to receive a copy of the Lienor's Noticeas provided in Section 713.13(1)(b), Florida Statutes. Phone number: 9. Expiration Date of Notice of Commencement (The expiration is 1 year from date of recording unless a different date is specified) WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE. CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART I, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. Signature of Owner or Lessee, or Owner's or Lessee's Authorized Ofrleer/Director/Pertner/Menager) Print Name and Provide Signatory's Title/Office) State of rf riG N Countyof The fore, oingInstrument was acknowledged before me this 1 day of Dr . 20 by •%l X-++ OA41 Who is personalty known to me irOR Name of person making statement who has produced identification IJ type of identification produced: vsr w PHYLLIS I. GIBSON Vh MY COMMISSION # GG113127 EXPIRES: OCT 02, 2021 00 Bonded through 1st State Insurance S LIMITED POWER OF ATTORNEY Altamonte Springs, Casselberry, Lake Mary, Longwood, Sanford, Seminole County, Winter Springs Date: 9 - / ? I hereby name and appoint: KQ Vi n e9,.y,e_-ir- an agent of: Roof Top Services of Central Florida, Inc. Name of Company) to be my lawful attorney -in -fact to act for me to apply for, receipt for, sign for and do all things necessary to this appointment for (check only one option): All permits and applications submitted by this contractor. or X The specific permit and application for work located at: 200 S. Myrtle Ave Sanford, FL 32771 Street Address) Expiration Date for This Limited Power of Attorney: License Holder Name: Kristal k Wingate State License Number: CCC13 Signature of License Holder: STATE OF FLORIDA COUNTY OF Seminole 09-17-2019 The foregoing instrument was acknowledged before me this day of n c_— , 201 A , by Kristal A. Wingate who is X personally known to me or who has produced identification and who did (did not take an oath. Signature VJ Notary Seal) } jb 6-i^ Y' Print or type name DEBORAH PIYBON CPU9C = MISSION # GG 102302 Notary Public -State of I 1o r I 0 ci_ MY COM tember A, 2021 a EXPIRES: SeP Public Underwriters Commission No. CO ` 3 O Bonded7hruNotary My Commission Expires: a0a/ Rev. 8/06/13) as Y'600F ®®r 5E9'S!I'iiESRErcOFCENTRALFLORIDA, INC. t<tntGLCOy - Fb, . AnM<ul BB. W & C®aft® cuko1750 Belle Avenue, Suite #1060, Winter Springs, FL 32708 hts www. rooftopservicea.com • 407.696.ROOF (7663) • Fax: 407,696.7664 • state cert.# CCC1326679 100FING CONSULTANT: _A*,ps p4 cc CONSULTANT'S CELL: L/0`7' PROPOSAL PREPARED FOR:, 1 JINSPECTION DATE: e' ADDRESS: r4act> w4 HOME PH: CELL PHO Z 163Aue7CITY, STATE, ZIP: a-" V_L, 22 T WORK PH: E-MAIL: w of bari19? ma t 10B LOCATION (if different from addressabove): AFTER A VISUAL INSPECTION OF THE JOBSITE, WE HEREBY RESPECTFULLY SUBMIT THE FOLLOWING ESTIMATE: PREPARATION LM / Obtain necessary insurances, permits and inspections in accordance with the current Florida Building Code. L9'Inspect property and take necessary precautions to protect structure's exterior and landscaping. MD e ove () layer(s) of existing roofing in its entirety & properly dispose of all related trash and debris DECKING & WOOD REPLACEMENT l!r]'( nspectthe existing roof deck, soffit and fascia board for any rotten/damaged wood and replace as needed per the following pricing schedule: @ _ Plywood - $ S / Per Sheet 1X - $ f linearfoot 2X - $ O - /linear foot Fasci (Pine/ Spruce) $7,— /linearfoot Fascia (Cedar) $ (U /linearfoot g'Provide & install additional decking fasteners as needed to ensure compliance with the current Florida Building Code. UNDERLAYMENTS L7 Provide & install a Synthetic Roof Underlayment to the prepared roof deck; fastened to ensure compliance with the current Florida Building Code Nail Pattern. Provide & install a double layer of 15LB. UL Felt Paper Underlayment to prepared deck of low slope roof; fastened to ensure compliance with the current Florida Building Code Nail Pattern. Provide & install a self -adhering Waterproof Leak Barrier to prepared roof deck. VENTILATION Provide & install 10-ft. Aluminum Pre -Finished Ridge Vent Proyvide & install 4-ft. Galvanized Metal Pre -Finished Off Ridge Vent ' C57 Provide & install & 0 LF of Shingle -Over Vent 11145'r' ovide & installZ 4-in. Finished Galvanized Metal Gooseneck Bath Vent Provide & install 10-in. Finished Galvanized Metal Gooseneck Kitchen Vent Provide & install Other Venting Color Selection: 6,'w. Standard factory painted finishes available for metal ventilation are Brown, Black, White or Mill Finish. FLASHINGS & MISCELLANEOUS Vvide & install 1%" pipe boot collar(s) Provide & install r 3" pipe boot collars(s) Provide & install 7_ 2" pipe boot collar(s) Provide & install 4" pipe boot collars(s) L9'Inspect flashings and replace as needed at a replacement cost of $ L1, So linear foot 0Provide & install ' 30 LF of Self Adhering Waterproof Leak Barrier & 26-Gauge Galvanized Valley Metal to a I valley(s). VrProvide & install 220 LF of new standard pre -finished, 2%-in. 26-Gauge Galvanized Metal Drip Edge to perimeter of roof. PPc. Color Selection: wtikl Standard factory painted finishes available for metal drip edge are Brown, Black, White, Beige, Grey or Mill Finish. Acrylic / Glass Quantity: Acrylic / Glass Quantity: SUN TUNNEL Quantity: SKYLIGHTS & SUN TUNNELS Size: Model #, Size: Model # Size: Model # HIP & RID E Provide & install Standard Ridge. rovide & install High Definition Ridge. ADDITIONAL WORK TO BE INCLUDED CONTRACT CLEAN-UP i K an gutters free of all debris/waste generated by this construction. Pf dorm adaily magnetic sweep of entire jobsite. IE[16eanupandproperlydisposeofallworkrelatedtrashand debris generated by this construction daily. Manufacturer Warranty: L'•K Workmanship Warranty: j ---. Shingle Series:. ( I 1/VurVJ-," Pe — Color: JAF-' 42 w c) 1 Sub - Total: F xOPTION42 3dlrmfial" P Manufacturer Warranty: Workmanship Warranty: Shingle Series: Color: 2 Sub - Total: Mftl OPT10N # 3 r y'Initlal ; ` i Manufacturer Warranty: Workmanship Warranty: Shingle Series: Color: 3 Sub - Total: X W SLOPE 1100F f 4lmfial k u Manufacturer Warranty: Tapered Package/] nsulation: Workmanship Warranty: Material Type: Color: Low Slope Sub -Total: Roof Top Services of Central Florida, Inc. hereby proposes to furnish material and labor complete and in accordance with above description and specifications, for the total sum of $I r S PAYMEENNTISDUE INFULL IMMEDIATELY UPON.COMPLETIONOFWORK ACCEPTANCE OF PROPOSAL: By si ning this contract, IDa m aauthorizir ROOF TOPSRVICES OF CENTRAL FLORIDA, INC.. to do the work as described above. The above specifications, conditions and prices are satisfactory and hereby accepted. You are authorized to do the work as specified. I understand and agree that payment will be made in full immediately upon completion of work. kt( 4011+wiolkL jL KL6-'WjE:'k 6.>(L( 13C— IPkUn jO ocbl--wP smQ tc-6 5 Signature: `-- Acceptance Date: C2c-+ ')' ZDw> ROOF TOP SERVICES IS NOT RESPONSIBLE FOR LOW SLOPES OR PONDING WATER. we Keel -he O DI/fd' - o! e-*e SM shire .iA. Altamonte Springs, Casselberry, Lake Mary, Longwood, Sanford, Seminole County, Winter Springs Date: 10-29-18 I hereby name and appoint: Kevin Beaver an agent of: Roof Top Services of Central Florida, Inc. Name of Company) to be my lawful attorney -in -fact to act for me to apply for, receipt for, sign for and do all things necessary to this appointment for (check only one option): All permits and applications submitted by this contractor. or X The specific permit and application for work located at: 103 Morrison Ave., Sanford, FL 32771 Street Address) Expiration Date for This Limited Power of Attorney: License Holder Name: Kristal A. Wingate State License Number: CCC 1326679 Signature of License Holder: STATE OF FLORIDA COUNTY OF Seminole The foregoing instrument was acknowledged before me this 29th day of oct. , 2018 , by Kristal A. Wingate who is X personally known to me or who has produced identification and who did (did not take an oath. Notary Seal) rY, ,. •.,,,,. DEBORAH PLYBON h MY COMMISSION # GG 102302 o EXPIRES: September 4, 20?1 FOc r'\.:• Bonded Thru Notary Public Under-".r... ;i: Signature Deborah Plyhon Print or type name Notary Public - State of Florida Commission No. GG102302 My Commission Expires: Sept. 04, 2021 as Rev. 8/06/13) D City of Sanford Building Division Residential Rc=Roof. Inspection Policy & Procedures PERMITTING REQUIREMENTS —NO PLAN REVIEw REQUIRED This document (signed) along with an accurate and completed Residential Re -Roof Scope of Work are required to be submitted as part of your permit application. The Scope of Work must include all applicable Florida Product Approval numbers for all roof components that will be installed on the project. A permit will not be issued without these documents. Copies will be made to post on the job site. Projects located in the Sanford Historic Districtwilf require plan review and approval by the Sanford. Historic Preservation Board INSPECTION POLICY & PROCEDURES A Final Root' Inspection is the only inspection required for Residential (Single Family, Townhouse, Mobile Home, Apartment and/or Condominium) Re -Roof "Permits. The Following is required to be provide on the job site: Permit Card, posted in a conspicuous and weatherproof location Completed Residential Re -Roof Scope of Work Completed and Notarized Inspection Affidavit All Florida Product Approval and Corresponding Installation Instructions Product Approval shall match what is on the scope of work) Digital Photographs (must include the permit number or address in each ,picture) o Each plane of the roof, showing the underlayment installed o Roof Deck Nailing Pattern & Spacing (including a measuring device or ruler) o Roof Deck Nails used (including a measuring device or ruler showing size of nails) o Underlayment Pattern & Spacing (including a measuring device or ruler) o Drip Edge & Valley Attachment (including a measuring device or ruler) o Shingles installed, nail pattern and location of nails Skylights (if applicable) o Digital photographs showing all installation components, per FL Product Approval o Digital photographs showing all required flashing, per FL Product Approval Failure to follow these specific,guidelines will result in an affidavit provided by a Florida Design Professional (architect or engineer), certifying FBC code compliance by personal inspection. CONTRACTOR (Oft OWNER/BUILDER) SIGNATURE.: I D C ko`n- DATE: Q L_ 10/16/2018 SCPA Parcel View: 12-20-30-511-0000-0820 I)avlbJohnson, CFA 111, fNax%-Ccoisrrv, Ft.gFtaSA Parcel Information Property Record Card Parcel: 12-20-30-511-0000-0820 Property Address: 103 MORRISON AVE SANFORD, FL 32773 Parcel 12-20-30-511-0000-0820-------_-- - Owner(s) WELBORN, BRADFORD WELBORN, CRISTAL Property Address 103 MORRISON AVE SANFORD, FL 32773 Mailing 201 FRYER LN SANFORD, FL 32773-9605 Subdivision Name MONROE MEADOWS Tax'District S1-SANFORD DOR Use Code 01-SINGLE FAMILY Exemptions 01 C) N Legal Description LOT 82 MONROE MEADOWS PB46PGS16&17 Taxes V ' C) N IM Taxing Authority Assessment Value -- Exempt Values — Taxable Value County General Fund 105,217 0 $105,217 Schools 119,711 0 -$119 711 105,217CitySanford105,217 0 SJWM(Saint Johns Water Management) 105,217 0 , $105,217 County Bonds_ - 105,217 0 $105,217 Sales Description Date Book Page Amount Qualified Vac/Imp WARRANTY DEED 13/1/2008 06951 i 1771 100 No Improved ADMINISTRATIVE DEED 3/1/2008 06951 1770 L— 155,000 No Improved WARRANTY DEED 2/1/1998 02985 03380 0432 67,000 Yes Improved WARRANTY DEED 10/1/1995 1262 68,100 Yes Improved Find Cemparahle Sa Land Method Frontage Depth Units Units Price Land Value LOT i 0.00 0.00 1 $25 000.00 25,000 Building Information Is Bed/Bath count incorrect? Click Here. r---- http://parceldetail.scpafl.org/ParceiDetail info.aspx?PI D=1220305110000082O 1 /2 10/16/2018 SCPA Parcel View: 12-20-30-511-0000-0820 Description Year Built Actual/Effective Fixtures Bed Bath Base Area Total SF Living SFP Wall Adj Value Repl Value Appendages 1 SINGLE i 1995 6 2 20 966 j 1,444 1,076 1 CONC 94,711 104,078 ' Description' AreaFAMILYiiIiBLOCKi i I j GARAGE (336.00 I FINISHED i i OPEN PORCH 32.00 I i FINISHED ' i BASE 110.00 Permits Permit # Description Agency Amount CO Date Permit Date 00769 }FENCE -- SANFORD $985 11/1/1996 — 02411 SFR SANFORD $57,000 8/1/1995 Permit data does not originate from the Seminole County Property Appraiser's office. For details or questions concerning a permit please contact the building department of the tax district Inwhich the property Is located.— Extra Features Description _ -- Year Built — Units Value New Cost No Extra Features http://parceldetail.scpafl.org/ParcelDetaiIInfo.aspx?PID=12203051100000820 2/2 f R PERMIT # JV - 4 JOB ADDRESS: 103 Morrison Ave., Sanford, FL 32771 City of Sanford Building Division Residential Re -Roof Scope of Work STRUCTURE TYPE: ® SINGLE FAMILY RESIDENCE/TOWNHOUSE O MOBILE HOME O APARTMENT/CONDOMINIUM RE -ROOF TYPE: © REPLACEMENT (TEAR OFF EXISTING ROOF AND REPLACE WITH NEW COMPONENTS) O RE-COVER (NEW ROOF INSTALLED OVER EXISTING ROOF DECK TYPE (PLEASE SPECIFY: 1 /2" plywood PLEASE NOTE: ONLY 100 SQUARE FEET OF THE EXISTING DECK IS PERMITTED TO BE REPLACED" ROOF VENTILATION: 0OFF-RIDGE O RIDGE 0SOFFIT QPOWERED VENT QTURBINES Shingle Over SKYLIGHTS: O YES © NO IF YES, PLEASE PROVIDE FLORIDA PRODUCT APPROVAL #: MAIN ROOF AREA ROOF SLOPE: Q LESS THAN 2:12 O 2:12-4:12 Q 4:12 OR GREATER TYPE OF ROOF MANUFACTURER FLORIDA PRODUCT APPROVAL O SHINGLE GAF FL# 10124-R20 Q METAL FL# O MODIFIED BITUMEN FL# Q TORCH DOWN FL# 0INSULATED FL# Q TILE FL# Z)OTHER: Underlayment GAF FL# 10626-R14 ROOF EXTENSIONS (PORCHES, PATIOS, ETC.) **IF APPLICABLE** ROOF SLOPE: O LESS THAN 2:12 O 2:12-4:12 O 4:12 OR GREATER TYPE OF ROOF MANUFACTURER FLORIDA PRODUCT APPROVAL O SHINGLE FL# Q METAL FL# O MODIFIED BITUMEN FL# Q TORCH DOWN FL# . O INSULATED FL# Q TILE FL# 0 OTHER: FL# City of Sanford Building and Fire Prevention Product Approval Specification Form Permit # Project Location Address 103 Morrison Ave.. Sanford. FL 32771 As required by Florida Statute 553.842 and Florida Administrative Code 9N-3, please provide the information and product approval number(s) on the building components listed below if they are to be utilized on the construction project for which you are applying for a building permit. We recommend that you contact your local product supplier should you not know the product approval number for any of the applicable listed products. Be aware that windows, skylights, and exterior doors must be tested in accordance with the Florida Building Code, Section 1714.5. More information about Statewide Product Approval can be obtained at www.floridabuilding.org. The following information must be available on the jobsite for inspections: 1. This entire product approval form 2. A copy of the manufacturer's installation details and requirements for each product. Category / Subcategory Manufacturer Product Description Florida Approval # include decimal) 1. Exterior Doors Swinging Sliding Sectional Roll U Automatic Other 2. Windows Single Hun Horizontal Slider Casement Double Hun Fixed Awning Pass Through Projected Mullions Wind Breaker Dual Action Other June 2014 Category / Subcategory Manufacturer Product Description Florida Approval # including decimal 3. Panel Walls Siding Soffits Storefronts Curtain Walls Wall Louver Glass block Membrane Greenhouse E.P.S Composite Panels Other 4. Roofing Products Asphalt Shingles GAF Timberline HD FL10124-R-20 Underla ments GAF Tiger Paw FL10626-R14 Roofing Fasteners Nonstructural Metal Roofing Wood Shakes and Shingles Roofing tiles Roofing Insulation Waterproofing Built up roofing System Modified Bitumen Single Ply Roof Systems Roofing slate Cements/ Adhesives / Coating Liquid Applied Roofing Systems Roof Tile adhesive Spray Applied Polyurethane Roofing E.P.S. Roof Panels Roof Vents Other June 2014 Category / Subcategory Manufacturer Product Description Florida Approval # include decimal S. Shutters Accordion Bahama Colonial Roll u Equipment Other 6. Skylights Skylights Other 7. Structural Components Wood Connectors / Anchors Truss Plates Engineered Lumber Railing Coolers/Freezers Concrete Admixtures Precast Lintels Insulation Forms Plastics Deck / Roof Wall Prefab Sheds Other 8. New Exterior Envelope Products Applicant's Signature Applicant's Name Kristal A. Wingate Please Print) June 2014 1/2/2018 Florida Building Code Online soc 1 BCIS Home ( Log In User Registration ' Hot Topics + Submit Surcharge Stats & Facts Publications FBC Staff BCIS Site Map Links Search dbd Product Approval p USER: Public User Product Approval Menu > Product or Application Search > Application List > Application Detail FL # FL10124-R20 Application Type Revision Code Version 2017 Application Status Approved Comments Archived Product Manufacturer GAF Address/Phone/Email 1 Campus Drive Parisppany, NJ 07054 800)766-3411 mstieh@gaf.com Authorized Signature Robert Nieminen lindareith@trinityerd.com Technical Representative William Broussard Address/Phone/Email 1 Campus Drive Parsippany, NJ 07054 800)766-3411 TechnicalQuestionsGAF@gaf.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Asphalt Shingles Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Robert Nieminen Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 10/20/2018 Validated By John W. Knezevich, PE Validation Checklist - Hardcopy Received Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By FL10124 R20 COI 2017 01 COI Nieminen.odf Standard Year ASTM D1970 2015 ASTM D3161 2016 ASTM D3462 2010 ASTM D7158 2011 TAS 107 1995 https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDquracBeVCbdMQNZD6Zesy3BoOyLwXhMdCmfpylEOlvyCA°/`3d`/o3d 1/2 1 /2/2018 Sections from the Code Florida Building Code Online Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Summary of Products Method 1 Option D 09/20/2017 09/27/2017 09/28/2017 12/12/2017 FL # Model, Number or Name Description 10124.1 GAF Asphalt Roof Shingles Fiberglass reinforced 3-tab, laminated, 5-tab and hip/ridge asphalt shingles Limits of Use Installation Instructions Approved for use in HVHZ: No FL10124 R20 II 2017 09 FINAL ER GAF Asphalt Shingles FL10124-R20.DdfApprovedforuseoutsideHVHZ: Yes Impact Resistant: N/A Verified By: Robert Nieminen PE-59166 Design Pressure: N/A Created by Independent Third Party: Yes Other: Refer to ER, Section 5. Evaluation Reports FL10124 R20 AE 2017 09 FINAL ER GAF Asphalt Shingles FL10124-R20.odf Created by Independent Third Party: Yes back Next Contact Us :: 2601 Blair Stone Road. Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. -Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: ECtieck go Credit Card Safe hftps://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDquracBeVCbdMQNZD6Zesy3BoOyLwXhMdCmfpylEOIVYCAg/g3dg/o3d 2/2 9/18/2.018 Florida Building Code Online f ti; 1s WA BCIS Home I Login I User Registration Hot Topics ( Submit Surcharge Stats & Facts Publications Contact Us ' BCIS site Map1 Links Search Florida Product Approval USER: Public User IXv ,, yr rod t Approval Menu > Product or Application Search > [ppatlon List > Application Detail FL # FL10626-R14 Application Type Revision Code Version 2017 Application Status Approved Comments Archived Product Manufacturer GAF Address/Phone/Email 1 Campus Drive Parlsppany, NJ 07054 800) 766-3411 mstieh@gaf.com Authorized Signature Robert Nieminen Iindar@nemoetc.com Technical Representative William Broussard Address/Phone/Email 1 Campus Drive Parsippany, NJ 07054 800) 766-3411 TechnlcalQuestlonsGAF@gaf.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Underlayments Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Robert Nieminen Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 06/16/2019 Validated By John W. Knezevich, PE Validation Checklist - Hardcopy Received Certificate of Independence FL10626 R14 COI 2018 O1 COI NIEMINEN.pdf Referenced Standard and Year (of Standard) Standard Year ASTM D1970 2015 ASTM D226 (physicals) 2009 ASTM D4533 (tear) 2015 ASTM D6164 2011 ASTM D6757 2016 FM 4474 2011 FRSA/TRI April 2012 (04-17) 2012 Equivalence of Product Standards Certified By https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtBNbEY5V%2boQYgnVE2RUHVOuwgULxCexQlywpOl%2b2iL%2fA%3d%3d 1/2 9/18/2018 Florida Building Code Online Sections from the Code Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Summary of Products Method 1 Option D 06/05/2018 06/16/2018 06/26/2018 08/15/2018 FL # Model, Number or Name Description 10626.1 GAF Roof Underlayments Roofing Underlayments for use in sloped roof systems Limits of Use Installation Instructions Approved for use In HVHZ: No Approved for use outside HVHZ: Yes FL10626 R14 II 2018 06 FINAL ER GAF UNDERLAYMENTS FL10626- R14.pdf Impact Resistant: N/A Verified By: Robert Nlemlen 59166 Design Pressure: +N/A/-442.5 Created by Independent Third Party: Yes Other: 1.) The design pressure noted In this Evaluation Reports application relates to one particular underlayment FL10626 R14 AE 2018 06 FINAL ER GAF UNDER AVMENTS FL10626- RJA.pdfsystemforuseunderfoam -on tile systems. Refer to ER Section 5.6A for details. 2.) Refer to ER Section 5 for other Limits of Use. Created by Independent Third Party: Yes Ftaci< Next Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida Is an AA/EEO employer, Qgpyrjght 2007-2013 State of Florida.:: Privacy Statement :: Accessibility. Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released In response to a public -records request, do not send electronicmalltothisentity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487,1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address If they have one. The emalls provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, pleaseprovidetheDepartmentwithanemailaddresswhichcanbemadeavailabletothepublic. To determine If you are a licensee under Chapter 45S, F.S., please click here Product Approval Acceptst ER Credit Card Safe https://www.floridabuilding.org/pr/pr_app_dti.aspx?param=wGEVXQwtDgtBNbEY5Va/a2boQY9nVE2RUHVOuwgULxCexQlywp01%2b2iLe/*2fA%3d°/a3d 2/2 MEMO I etc. Certificate of Authorization #32455 353 Christian Street, Unit #13 Oxford, CT 06478 203) 262-9245 ENGINEER EVALUATE TEST CONSULT CERTIFY GAF Evaluation Report 01506.04.08-R14 1Campus Drive FL10626-R14 Parsippany, NJ 07054 Date of Issuance: 04/25/2008 800) 766-3411 Revision 14: 06/06/2018 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 6th Edition (2017) Florida Building Code sections noted herein. DESCRIPTION: GAF Roof Underlayments LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the product(s), the Quality Assurance or the production facility location(s). NEMO I etc. requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "NEMOIetc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 11. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCA ANE1983 nngeu, p .,., .. , ot'•JT; The facsimile seal appearing was authorized by Robert I+ FS' •g •4i? Nleminen, P.E. on 06/05/2018. This does not serve as an electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. NEMO ETC, LLC does not have, nor does it Intend to acquire, or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being Issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. S. This is a building code evaluation. Neither NEMO Ietc. nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. ONEMO I etc. ROOFING COMPONENT EVALUATION: Product Category: Roofing Sub -Category: Underlayment Compliance Statement: GAF Roof Underlayments, as produced by GAF, have demonstrated compliance with the following sections of the Florida Building Code through testing in accordance with the following Standards, Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. Section Property Standard Year 1504.3.1 Wind Uplift FM 4474 2011 1507.1.1, R905,1.1 Exception Unrolling, Breaking Strength, ASTM D226 2009 Pliability 1507.1.1, R905.1.1 Exception Tear Strength ASTM D4533 2015 1507.2.3 / 1507.1.1 Physical Properties ASTM D6757 2016 1507.2.4 / 1507.1.1, 1507.2.9.2 Physical Properties ASTM D1970 2015 1507.3.3 Physical properties FRSA/TRI April 2012 (04-12) 2012 1507.11.2 Physical Properties ASTM D6164 2011 Entity Examination Reference Date ERD (TST 6049) Physical Properties R3360.02.07-2-R1 03/13/2007, ERD (TST 6049) Physical Properties G12110,12.08 12/02/2008 ERD (TST 6049) FRSA/TRI April 2012 (Slippage) G34150.08.11 11/14/2011 ERD (TST 6049) ASTM D6164 G40630.01.14-2B 01/07/2014 ERD (TST 6049) ASTM D6164 G46160.09.14-3A 09/09/2014 ERD (TST 6049) ASTM D1970 GAF-SC13285.03,17-3 03/01/2017 ERD (TST 6049) ASTM D1970 GAF-SC13285.03.17-4 03/01/2017 PRI (TST 5878) Physical properties BRY-003-02-01 03/19/2002 PRI (TST 5878) ASTM D1970 GAF-026-02-01 03/26/2002 PRI (TST 5878) ASTM D1970 GAF-027-02-01 03/26/2002 PRI (TST 5878) Physical properties GAF-042-02-01 06/03/2005 PRI (TST 5878) Physical properties GAF-224-02-01 07/27/2009 PRI (TST 5878) ASTM D1970 GAF-238-02-01 03/03/2010 PRI (TST 5878) ASTM D1970 GAF-275-02-01 11/11/2010 PRI (TST 5878) Physical properties GAF-349-02-01 07/03/2012 PRI (TST 5878) Wind Uplift GAF-434-02-01 09/16/2013 PRI (TST 5878) Wind Uplift GAF-434-02-03 09/16/2013 PRI (TST 5878) Wind Uplift GAF-434-02-04 09/16/2013 PRI (TST 5878) FBC 1507.1.1 (Exception) GAF-818-02-01 12/05/2017 PRI (TST 5878) FBC 1507.1.1 (Exception) GAF-826-02-01 06/04/2018 PRI (TST 5878) FBC 1507.1.1 (Exception) GAF-847-02-01 06/04/2018 UL (TST 1740) Physical properties 02NK22569 06/04/2002 UL(TST 1740) ASTM D6757 IONK11990 05/18/2011 Miami -Dade (CER 1592) HVHZ compliance 16-1216.02 02/02/2017 Miami -Dade (CER 1592) HVHZ compliance 18-0119.15 02/22/2018 ICC-ES (EVL2396) IBC/IRC compliance ESR-2053 07/01/2017 ICC-ES (EVL2396) IBC/IRC compliance ESR-2808 07/01/2017 ICC-ES (EVL2396) IBC/IRC compliance ESR-1322 01/01/2018 ICC-ES (EVL2396) IBC/IRC compliance ESR-3286 02/01/2018 UL, LLC (QUA 9625) Quality Control Inspect, File R10689 (BC) 06/27/2017 UL, LLC (QUA 9625) Quality Control Inspect, File R10689 (CA) 07/07/2017 UL, LLC. (QUA 9625) Quality Control Inspect, File R10689 (GA) 02/02/2018 UL, LLC. (QUA 9625) Quality Control Inspect, File R10689 (IN) 01/10/2018 NEMO ETC, LLC Evaluation Report 01506.04.08-1114 Certificate ofAuthor/satlon g314SS 6T"EDITION (2017) FBC NON-HVHZ EVALUATION FL10626-R14 GAF Roof Underlayments; (800) 766.3411 Revision 14: 06/OS/2018 Page 2 of 11 ONEMO ( etc. Entity Examination Reference Date UL, LLC. (QUA 9625) Quality Control Inspect, File R10689 (NC) 03/14/2018 UL, LLC (QUA 9625) Quality Control Inspect, File R10689 (OK) 06/20/2017 UL, LLC (QUA 9625) Quality Control Inspect, File R10689 (ON, QC) 05/18/2018 UL, LLC (QUA 9625) Quality Control Inspect, File R10689 (SC) 06/16/2017 UL, LLC (QUA 9625) Quality Control Inspect, File R10689 (TX) 05/24/2016 UL, LLC (QUA 9625) Quality Control Inspect, File R10689 (INDIA) 04/13/2018 UL, LLC (QUA 9625) Quality Control Inspect, File R10689 (LA) 04/23/2018 eese - 4A Self -Adhering Underlayments: 4. 1.1 Liberty" SBS Self -Adhering Base/Ply Sheet is a smooth -surfaced, fiberglass -reinforced, self -adhering SBS modified bitumen roof underlayment; meets ASTM D1970. 4. 1.2 StormGuard® Film Surfaced Leak Barrier is a film -surfaced, fiberglass -reinforced, self -adhering 565 modified bitumen roof underlayment; meets ASTM D1970, StormGuard® Film Surfaced Leak Barrier is also used as a secondary water barrier to seal roof decks. 4. 1.3 WeatherWatch® Mineral Surfaced Leak Barrier is a mineral -surfaced, fiberglass -reinforced, self -adhering SBS modified bitumen roof underlayment; meets ASTM D1970. WeatherWatch® Mineral Surfaced Leak Barrier is also used as a secondary water barrier to seal roof decks. 4. 2 Mechanically Fastened Underlayments: 4. 2.1 VersaShleld® Fire -Resistant Roof Deck Protection is a non -asphaltic, fiberglass -based roof underlayment and/or fire barrier; meets physical requirements of ASTM D6757. 4. 2.2 Deck -Armor"' Premium Breathable Roof Deck Protection is a non -woven, spun -bonded polypropylene laminated polyethylene scrim sheet roof underlayment, available in 48-Inch or 54-inch roll widths; meets FBC 1507.1.1 & R905. 1.1 (Exception). 4. 2.3 RoofProT" SBS-Modified All -Purpose Underlayment is a fiberglass -reinforced, SBS modified bitumen roof underlayment; meets AC165. 4. 2.4 Shingle -Mate® Roof Deck Protection is a fiberglass reinforced, asphaltic roof underlayment; meets FBC 1507.1.1 & R905. 1.1 (Exception). 4. 2.5 StormSafe*"' Anchor Sheet is a polypropylene woven fabric which serves as an anchor sheet in two-ply roof underlayment systems; meets FBC 1507.1.1 & R905.1.1 (Exception). 4. 2.6 Tiger Paw'"' Roof Deck Protection is a non -woven, polypropylene reinforced, polymer coated roof underlayment; meets FBC 1507.1.1 & R905.1.1 (Exception). 4. 3 Asphalt -Applied Underlayments: 4. 3.1 Ruberoid® Mop Granule is a granule -surfaced, polyester -reinforced, asphalt -applied SBS modified bitumen roof underlayment; meets ASTM D6164. 4. 3.2 Ruberoid® Mop Granule FR is a granule -surfaced, polyester -reinforced, asphalt -applied SBS modified bitumen roof underlayment; meets ASTM D6164. NEMO ETC, LLC Evaluation Report 01506.04.08-1114 Certificate ofAuthorization #32455 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL10626-1114 GAF Roof Underlayments; (800) 766-3411 Revision 14: 06/05/2018 Page 3 of 11 ONEMO I etc. 5.1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, In any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. 5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory or test report from accredited testing agency for fire ratings of this product. 5.4 GAF Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering. 5.5 Allowable Roof Covers: Asphalt Foam -On Wood Slate or Underlayment Shingles Nall -On Tile Tile Metal Shakes & Simulated Shingles Slate Deck -Armor"" Premium Breathable Yes No No Contact Contact Contact Roof Deck Protection GAF GAF GAF RoofPro"" SBS-Modifled All -Purpose Underlayment Yes No No No Yes Yes Shingle -Mate® Roof Deck Protection Yes No No No No No Tiger PawTm Roof Deck Protection Yes No No Contact Contact Contact GAF GAF GAF VersaShield® Flre-Resistant Roof Deck Protection Yes No No No No No Liberty'"" SIBS Self -Adhering Base/Ply Sheet Yes No No No No No StormGuard® Film Surfaced Leak Barrier Yes No No Yes No No WeatherWatch® Mineral Surfaced Leak Barrier Yes No No No No No Ruberold® Mop Granule Yes Yes Yes No Yes YesSee5.5.1 Ruberold® Mop Granule FR Yes Yes Yes No Yes YesSee5.5.1 5.5.1 "Foam -On Tile" is limited to use of the followins Approved tile adhesives / underiavmPnt rntnhinatinna Adhesive Florida Product Approval7DowileBond'"' Underlayments FL22525 Ruberold® Mop Granule; Ruberold® Mop Granule FR 1 Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance. NEMO ETC, LLC Evaluation Report 01506.04.08-Ri4CertificateofAuthorizatton #32455 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL10626-R14 GAF Roof Underlayments; (800) 766-3411 Revision 14: 06/05/2018 Page 4 of 11 J ONEMOletc. 5.6 Allowable Substrates: 5.6.1 Direct -Bond to Deck: Liberty'"" SBS Self -Adhering Base/Ply Sheet; StormGuard® Film Surfaced Leak Barrier and Weather Watch® Mineral Surfaced Leak Barrier self -adhered to new untreated plywood or existing untreated ASTM D41 primed plywood. Ruberoid® Mop Granule and Ruberoidm Mop Granule FR in hot asphalt to ASTM D41 primed structural concrete. 5.6.2 Bond to Mechanically Attached Base Laver: Liberty'm SBS Self -Adhering Base/Ply Sheet; StormGuard® Film Surfaced Leak Barrier and WeatherWatch® Mineral Surfaced Leak Barrier self -adhered to ASTM D226, Type II felt Ruberoid® Mop Granule and Ruberoid® Mop Granule FR in hot asphalt to GAFGLAS® #80 Ultima'" Base Sheet or Ruberoid® 20 Smooth. 5.6.3 Bond to Other Substrate Tvpes: ASTM D41 primed metal (flashing metal, valley metal, etc.) 5.6.4 Wind Resistance for Underlayment Systems in Foam -On Tile Applications: FRSA/TRI April 2012 (04-12) does not address wind uplift resistance of all underlayment systems beneath foam - on or mortar -set tile systems, where the underlayment forms part of the load -path. The following wind uplift limitations apply to underlayment systems that are not addressed In FRSA/TRI April 2012 (04-12) and are used in foam -on or mortar -set tile applications. Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FRSA/TRI April 2012 (04-12), Appendix A, Table 1A or FBC 1609 for determination of design wind loads. 1 Maximum Design Pressure = -45 psf. Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Layer: GAFGLAS® #80 Ultima'" Base Sheet or Ruberoid® 20 Smooth mechanically attached with 12 ga., min. 1.25-inch long ring shank nails through 32 ga., 1-5/8-inch diameter tin caps spaced 9-Inch o.c. at the 4-inch wide side laps and 9-inch o.c. at two (2), equally spaced, staggered center in the field of the sheet. Top Layer: Ruberoid® Mop Granule or Ruberoid® Mop Granule FR applied in full mopping of ASTM D312, Type IV hot asphalt at 20 to 25 Ibs/square. 2 Maximum Design Pressure = -75 psf. Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Layer: GAFGLAS® #80 UltimaTm Base Sheet or Ruberoid® 20 Smooth mechanically attached with 12 ga., min. 1.25-inch long ring shank nails through 32 ga., 1-5/8-inch diameter tin caps spaced 8-inch o.c. at the 4-inch wide side laps and 8-inch o.c. at three (3), equally spaced, staggered center in the field of the sheet. Top Layer: Ruberoid® Mop Granule or Ruberoid® Mop Granule FR applied in full mopping of ASTM D312, Type IV hot asphalt at 20 to 25 Ibs/square. 3 Maximum Design Pressure = -442.5 psf. Deck: Min. 2,500 psi structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction Base Layer: GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Ply 4, Tri-Ply Ply 4 or GAFGLAS Flex Ply 6 applied in full mopping of ASTM D312, Type IV hot asphalt at 20 to 25 Ibs/square. Top Layer: Ruberoid® Mop Granule or Ruberoid® Mop Granule FR applied in full mopping of ASTM D312, Type IV hot asphalt at 20 to 25 Ibs/square. NEMO ETC, LLC Evaluation Report 01506.04.08•R34 Certificate ofAuthorization #324SS 6T" EDITION (2017) FBC NON•HVHZ EVALUATION F1.10626-1114 GAF Roof Underlayments; (800) 766-3411 Revision 14: 06/OS/2018 Page S of 11 NEMO I etc. 5.6.4.1 For mechanically attached Base Sheet, the maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI April 2012 (04-12), Appendix A, Table 1A. Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC 1609. In this case, Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29 and Roofing Application Standard RAS 117. Assemblies marked with an asterisk* carry the limitations set forth In Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January 2016) for Zone 2/3 enhancements. 5.7 Exposure Limitations: 5.7.1 Deck -Armor'"' Premium Breathable Roof Deck Protection; RoofPro'"' SBS-Modified All -Purpose Underlayment; Shingle -Mate® Roof Deck Protection; StormSafelm Anchor Sheet and Tiger Paw'" Roof Deck Protection shall not be left exposed for longer than 30-days after Installation. 5.7.2 VersaShield® Flre-Resistant Roof Deck Protection, Ruberoid® Mop Granule and Ruberoid® Mop Granule FR shall not be left exposed for longer than 180-days after Installation. 5.7.3 Liberty'" SBS Self -Adhering Base/Ply Sheet; StormGuard® Film Surfaced Leak Barrier and WeatherWatch® Mineral Surfaced Leak Barrier shall not be left exposed for longer than 30-days after Installation. 5.8 Tile Slippage Limitations RAS 103 per FRSA/TRI April 2012 (04-12)): When loading roof tiles on the underlayment in direct -deck tile assemblies, the maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles. Underlayment Tile Profile Staging Method Maximum Slope Ruberoid® Mop Granule Flat Max. 10-tile stack 4:12 Flat Max. 6-tile stack (4 over 2) 5:12 Lugged Max. 10-tile stack 5:12 Ruberoid® Mop Granule FR Flat or Lugged Max. 6-tile stack (4 over 2) 5:12 Lugged Max. 10-tile stack 4:12 6.1 GAF Roof Underlayments shall be installed in accordance with GAF published installation instructions subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application and prime the substrate (if applicable). 6.3 Install self -adhering underlayments when ambient temperatures are minimum 45T and rising. 6.4 All metal surfaces shall be primed with Matrix'"' 307 Premium Asphalt Primer or alternate GAF accepted ASTM D41 primer prior to application of self -adhering membranes. 6.5 Deck -Armor'" Premium Breathable Roof Deck Protection: 6.5.1 Shall be installed in compliance with the requirements for ASTM D226, Type I or it underlayment in FBC Table 1507.1.1 or R905.1.1 for the type of prepared roof covering to be installed, considering the wider sheet -width for double -layer applications. 6.5.2 Minimum fasteners shall be 1-inch diameter plastic -capped corrosion resistant nails or 1-inch diameter plastic - capped, corrosion resistant staples. Code Reference: The Exception statement in FBC 1507.1.1 and FBC R905.1.1 requires use of metal cap nails where the ultimate design wind speed, V„h, equals or exceeds 150 mph. NEMO ETC, LLC Cerdficate OfAutharizatlon N324SS 6T" EDITION (2017) FBC NON-HVHZ EVALUATION GAF Roof Underlayments; (800) 766-3411 Evaluation Report O1S06.04.08-R34 FL10626-R14 Revision 14: 06/OS/2018 Page 6 of 11 ONEMOjetc. 6.5.3 Optional, or if required by the Authority Having Jurisdiction: Install a leak barrier of LibertyT"^ SBS Self -Adhering Base/Ply Sheet; StormGuard° Film Surfaced Leak Barrier; UnderRoof l 2 Polyester -Surfaced Leak Barrier or WeatherWatch® Mineral Surfaced Leak Barrier at vulnerable leak areas, including but not limited to eaves, valleys, rakes, skylights and dormers. At eaves and valleys, install the leak barrier prior to installation of the underlayment. Along the rake, install the underlayment, leaving 6 to 8-inch of the deck exposed, and then install the leak barrier over the underlayment and exposed decking. At other areas, install the leak barrier over the underlayment. 6.5.4 Non -Tile Roof Installations: Single Laver; Roof Slope > 4:12: Starting at the eave, fasten the eave edge and 6-inch wide end -laps 6-inch D.C. Fasten in the field of the roll 12- inch D.C. in two, equally spaced, staggered center rows. Continue upslope in a similar manner, maintaining minimum 3-inch side -laps and minimum 6-inch end -laps. Fasten 6-inch D.C. in the laps and 12-inch o.c. in two, equally spaced, staggered center rows in the field. Ensure all end laps are staggered at least 3-feet apart. Double Laver: 2:12 < Roof Slope < 4:12: If leak barrier (6.3.3) is not used, install a half -width sheet at the eave prior to subsequent courses. Starting at the eave, fasten the eave edge and 6-inch wide end -laps 6-inch o.c. Fasten in the field of the roll 12-inch o.c. in two, equally spaced, staggered center rows. Continue upslope in a similar manner, with minimum 25.5-inch side -laps for 48-inch wide rolls (resulting in maximum 22.5-inch exposure) or minimum 28.5-inch side -laps for 54-inch wide rolls (resulting in maximum 25.5- inch exposure) and minimum 6-inch end -laps. Fasten 6-Inch D.C. along the low edge and end laps and 12-inch o.c. in two, equally spaced, staggered center rows in the field. Ensure all end laps are staggered at least 3-feet apart. 6.6 Tiger PawTm Roof Deck Protection: 6.6.1 Shall be installed in compliance with the requirements for ASTM D226, Type I or II underlayment in FBC Table 1507.1.1 or R905.1.1 for the type of prepared roof covering to be installed, considering the wider sheet -width for double -layer applications. 6.6.2 Minimum fasteners shall be 1-Inch diameter plastic -capped corrosion resistant nails or 1-inch diameter plastic - capped, corrosion resistant staples. Code Reference: The Exception statement in FBC 1507.1.1 and FBC R905.1.1 requires use of metal cap nails where the ultimate design wind speed, V It, equals or exceeds 150 mph. 6.6.3 Optional, or if required by the Authority Having Jurisdiction: Install a leak barrier of Liberty'°" SBS Self -Adhering Base/Ply Sheet; StormGuard® Film Surfaced Leak Barrier; UnderRoofT"" 2 Polyester -Surfaced Leak Barrier or WeatherWatch® Mineral Surfaced Leak Barrier at vulnerable leak areas, including but not limited to eaves, valleys, rakes, skylights and dormers. At eaves and valleys, install the leak barrier prior to installation of the underlayment. Along the rake, install the underlayment, leaving 6 to 8-inch of the deck exposed, and then install the leak barrier over the underlayment and exposed decking. At other areas, install the leak barrier over the underlayment. 6.6.4 Non -Tile Roof Installations: Single Laver; Roof Slope > 4:12: Starting at the eave, fasten the eave edge and 6-inch wide end -laps 6-inch D.C. Fasten in the field of the roll 12- inch o.c. in two, equally spaced, staggered center rows. Continue upslope in a similar manner, maintaining minimum 3-inch side -laps and minimum 6-inch end -laps. Fasten 6-inch o.c. in the laps and 12-inch D.C. in two, equally spaced, staggered center rows in the field. Ensure all end laps are staggered at least 3-feet apart. NEMO ETC, LLC Evaluation Report 01506.04.08-1134 Certificate ofAuthorization #32455 6T" EDITION (2017) FBC NON-HVHZ EVALUATION F1.10626-1114 GAF Roof Underiayments; (800) 766-3411 Revision 14: 06/05/2018 Page 7 of 11 ON EMO I etc. Double Laver; 2:12 < Roof Slope < 4:12: If leak barrier (6.4.3) is not used, install a half -width sheet at the eave prior to subsequent courses. Starting at the eave, fasten the eave edge and 6-inch wide end -laps 6-inch D.C. Fasten in the field of the roll 12-inch D.C. in two, equally spaced, staggered center rows. Continue upslope in a similar manner, with minimum 25.5-inch side -laps (resulting in maximum 22.5-inch exposure) and minimum 6-inch end -laps. Fasten 6-inch D.C. along the low edge and end laps and 12-inch D.C. in two, equally spaced, staggered center rows in the field. Ensure all end laps are staggered at least 3-feet apart. 6.7 StormSaf elm Anchor Sheet: 6.7.1 StormSafelm Anchor Sheet is limited to use as a mechanically attached base layer in 2-ply underlayment systems. 6.7.2 Minimum fasteners shall be 1-inch diameter plastic- or steel -capped corrosion resistant nails; corrosion -resistant nails & 1-5/8-Inch tin -caps; or Drill-Tec screws and plates. Code Reference: The Exception statement in FBC 1507.1.1 and FBC R905.1.1 requires use of metal cap nails where the ultimate design wind speed, V„It, equals or exceeds 150 mph. 6.7.3 Non -Tile Roof Installations: Starting at the eave, fasten the eave edge and 6-inch wide end -laps 6-inch o.c. Fasten in the field of the roll 12- Inch D.C. in two, equally spaced, staggered center rows. Continue upslope in a similar manner, maintaining minimum 3-inch side -laps and minimum 6-inch end -laps. Fasten 6-inch o.c. in the laps and 12-inch D.C. in two, equally spaced, staggered center rows in the field. Ensure all end laps are staggered at least 3-feet apart. One the same day, install Liberty'" SBS Self -Adhering Base/Ply; StormGuard® Film Surfaced Leak Barrier or WeatherWatch® Mineral Surfaced Leak Barrier over the StormSafell Anchor Sheet, 6.8 RoofProlm SBS-Modified All -Purpose Underlayment and Shingle -Mate® Roof Deck Protection: 6.8.1 Shall be installed in compliance with the requirements for ASTM D226, Type I or II underlayment In FBC Table 1507.1.1 or R905.1.1 for the type of prepared roof covering to be installed. No hammer tacks or staples are permitted. Code Reference: The Exception statement in FBC 1507.1.1 and FBC R905.1.1 requires use of metal cap nails where the ultimate design wind speed, V It, equals or exceeds 150 mph. 6.8.2 Optional, or if required by the Authority Having Jurisdiction: Install a leak barrier of LlbertyTM SBS Self -Adhering Base/Ply Sheet; StormGuard° Film Surfaced Leak Barrier or WeatherWatch® Mineral Surfaced Leak Barrier at vulnerable leak areas, Including but not limited to eaves, valleys, rakes, skylights and dormers. At eaves and valleys, install the leak barrier prior to installation of the underlayment. Along the rake, install the underlayment, leaving 6 to 8-inch of the deck exposed, and then install the leak barrier over the underlayment and exposed decking. At other areas, install the leak barrier over the underlayment. 6.9 VersaShield® Fire -Resistant Roof Deck Protection: 6.9.1 Shall be installed in compliance with the codified requirements for ASTM D67S7 underlayment in FBC Table 1507.1.1 for the type of prepared roof covering to be installed. No hammer tacks or staples are permitted. 6.9.2 Optional, or if required by the Authority Having Jurisdiction: Install a leak barrier of Liberty" SBS Self -Adhering Base/Ply Sheet; StormGuardm Film Surfaced Leak Barrier or WeatherWatch° Mineral Surfaced at vulnerable leak areas, including but not limited to eaves, valleys, rakes, skylights and dormers. At eaves and valleys, install the leak barrier prior to installation of the underlayment. Along the rake, install the underlayment, leaving 6 to 8-inch of the deck exposed, and then install the leak barrier over the underlayment and exposed decking. At other areas, install the leak barrier over the underlayment. NEMO ETC, LLC Evaluation Report 01506.04.08-1114CertificateofAuthorizatfon #32455 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL10626-R14 GAF Roof Underlayments; (800) 766-3411 Revision 14: 06/05/2018 Page 8 of 11 6.10 Liberty'- SBS Self -Adhering Base/Ply Sheet: ONEMOjetc. 6.10.1 Shall be installed in compliance with the codified requirements for ASTM D1970 underlayment in FBC Table 1507.1.1 for the type of prepared roof covering to be Installed. 6.10.2 The minimum and maximum roof slopes are %:12 and 6:12, respectively. Back -nailing is required when slope is 1:12 or greater. Back -nailing shall consist of minimum 1-inch square or round cap nails spaced 18" o.c. within 3- inch side laps. 6.10.3 Non -Tile Applications: Shall be fully self -adhered to the substrates noted in Section 5.6. For direct -bond to deck applications plywood shall be primed with Matrix'"' 307 Premium Asphalt Primer or alternate GAF accepted ASTM D41 primer at %2 to Y44 gallon per square. Prior to removal of release film, align sheets properly starting at the low -point of the roof (eave) with the selvage edge upslope and for minimum 2-inch overhang at eaves and rakes. Roll out sheet and allow to 'relax' for min. 30 minutes. Remove the lower piece of release film and bond to substrate and fold the overhanging 2-inch over the eave and nail Into place 12" o.c. Remove the top piece of release film and bond to substrate. Install primed drip edge and fasten to meet FBC Chapter 16 wind load requirements. Install 1/8-inch troweling of Matrix'"' 201 Premium SBS Flashing Cement over drip edge. Continue upslope in a similar manner, maintaining minimum 3-inch side -laps and minimum 6-inch end -laps. Ensure all end laps are staggered at least 18-inch apart. Use a weighted lawn or linoleum roller to ensure complete adhesion to the substrate. Use a hand roller to firmly bond side and end laps. 6.11 StormGuard® Film Surfaced Leak Barrier: 6.11.1 Shall be installed in compliance with the codified requirements for ASTM D1970 underlayment in FBC Table 1507.1.1 for the type of prepared roof covering to be installed. 6.11.2 Back -nailing is required. Back -nailing shall consist of minimum 1-inch square or round cap nails spaced 18" o.c. within 3-inch side laps. 6.11.3 Non -Tile Applications: Shall be fully self -adhered to the substrates noted in Section 5.6. Prior to removal of release film, align sheets properly starting at the low -point of the roof (eave) with the selvage edge upslope and for minimum 2-inch overhang at eaves and rakes. Remove the lower piece of release film and bond to substrate and fold the overhanging 2-Inch over the eave and nail into place 12 o.c. Remove the top piece of release film and bond to substrate. Install primed drip edge and fasten to meet FBC Chapter 16 wind load requirements. Install 1/8-inch troweling of Matrix'"" 201 Premium SBS Flashing Cement over drip edge. Continue upslope in a similar manner, maintaining minimum 3-inch side -laps and minimum 6-inch end -laps. Ensure all end laps are staggered at least 18-inch apart. Use a hand roller to firmly bond side and end laps. NEMO ETC, LLC Evaluation Report 01506.04.08-1114 CertificateofAuthorization #32455 6T" EDITION (2017) FBC NON-HVHZ EVALUATION F1.10626-1114 GAF Roof Underlayments; (800) 766.3411 Revision 14: 06/05/2018 Page 9 of 11 ONEMOletc. 6.12 WeatherWatch- Mineral Surfaced Leak Barrier: 6.12.1 Shall be installed in compliance with the codified requirements for ASTM D1970 underlayment in FBC Table 1507.1.1 for the type of prepared roof covering to be installed. 6.12.2 WeatherWatch- Mineral Surfaced Leak Barrier may be installed as a secondary water barrier using minimum 4- inch wide rolls to seal plywood deck joints prior to installation of the primary underlayment system. 6,12.3 Back -nailing is required. Back -nailing shal consist of minimum 1-inch square or round cap nails spaced 18" o.,c. within 4-inch side laps, 6,12.4 Non -Tile Applications: Shall be fully self -adhered to the substrates noted In Section 5.6. Prior to removal of release film, align sheets properly starting at the low -point of the roof (eave) with the selvage edge upslope and for minimum 2-Inch overhang at eaves and rakes. Remove the lower piece of release film and bond to substrate and fold the overhanging 2-Inch over the eave and nail Into place 12" D.C. Remove the top piece of release film and bond to substrate. Install primed drip edge and fasten to meet FBC Chapter 16 wind load requirements. Install 1/8-Inch troweling of Matrix'"' 201 Premium SBS Flashing Cement over drip edge. Continue upslope in a similar manner, maintaining minimum 3-inch side -laps and minimum 6-inch end -laps. Ensure all end laps are staggered at least 18-feet apart. Use a hand roller to firmly bond side and end laps. 6.13 Ruberoid- Mop Granule; Ruberoid- Mop Granule FR: 6,13.1 Ruberoid- Mop Granule or Ruberold- Mop Granule FR shall be installed in compliance with current GAF published Installation requirements. 6.13.2 For use in tile applications, Ruberold- Mop Granule or Ruberold- Mop Granule FR are for use as an alternate to Mineral Surface Roll Roofing" (ASTM D6380, Class M) in the "Single Ply System" from FRSA/TRI April 2012 (04- 12) beneath mechanically fastened tile roof systems or the Hot Asphalt applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened or adhered tile roof systems. 6.13.3 Fully adhere in ASTM D312, Type IV hot -asphalt to the substrates noted in Section 5.6. Side laps shall be minimum 4-Inch and end -laps minimum 6-inch wide, and offset end -laps minimum 3-feet from course to course. Side and end -laps shall be fully adhered in a complete mopping of hot asphalt with asphalt extending approximately 3/8-Inch beyond the lap edge. 6.13.4 Consult GAF instructions regarding back -nailing requirements. 6.14 Tile Staging (Ruberold- Mop Granule: Ruberoid- Mop Granule FR): 6.14.1 Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment. Refer to Table 2 herein, and GAF published requirements for the staging, 6.14.2 Battens and/or Counter -battens, as required by the tile manufacturer and FRSA/TRI April 2012 (04-12) must be used on all roof slopes greater than 7:12. Precautions should be taken as needed, such as the use of battens or nail -boards, to prevent the sliding and/or damage to the underlayment during the loading process. NEMO ETC, LLC Evaluation Report 01506.04.08-1134 Certificate ofAuthorization N32455 6'" EDITION (2017) FBC NON-HVHZ EVALUATION F1.10626-1134 GAF Roof Underlayments; (800) 766.3411 Revision 14: 06/05/2018 Page 10 of 11 As required by the Building Official or Authority product. fo'NlEmlo I etc. ng Jurisdiction to properly evaluate the installation of this Contact the noted CIA agency for information on product locations covered for F.A.C. 61G20-3 CIA requirements. The following plants have qualified products under their respective physical properties specifications. Plant Specification Product s Charleston, SC FBC 1507.1.1 (Exception) Tiger Paw'^' Roof Deck Protection Conover, NC ASTM D6757 VersaShield® Fire -Resistant Roof Deck Protection Dadra, India FBC 1507.1.1 (Exception) Tiger Paw'"' Roof Deck Protection Fontana, CA AC165 RoofPro'" SBS-Modified All -Purpose Underlayment Homer, LA FBC 1507.1.1 (Exception) Tiger Paw'" Roof Deck Protection (WIP) McGregor, TX FBC 1507.1.1 (Exception) Shingle -Mate® Roof Deck Protection Mission, BC FBC 1507.1.1 (Exception) Tiger Paw'"" Roof Deck Protection Mt. Vernon, IN ASTM D1970 Liberty'" SBS Self -Adhering Base/Ply Sheet; StormGuard® Film Surfaced Leak Barrier; WeatherWatch® Mineral Surfaced Leak Barrier North Bay, Ontario FBC 1507.1.1 (Exception) Deck -Armor'"' Premium Breathable Roof Deck Protection, StormSafeT, Anchor Sheet, Tiger Paw'"' Roof Deck Protection (conversion) Pryor, OK FBC 1507.1.1 (Exception) Shingle -Mate® Roof Deck Protection Savannah, GA ASTM D1970 StormGuard® Film Surfaced Leak Barrier; WeatherWatch® Mineral Surfaced Leak Barrier ASTM D6164 Ruberoid® Mop Granule; Ruberoid® Mop Granule FR 9 a QUALITYASSURANCE ENTITY END OF EVALUATION REPORT - NEMO ETC, LLC CertificateoJAuthorization #32455 6T" EDITION (2017) FBC NON-HVHZ EVALUATION GAF Roof Underlayments; (800) 766.3411 Evaluation Report 01506.04.08-1114 F1.10626-1414 Revision 14: 06/05/2018 Page 11 of 11 PERMIT ##: City of Sanford Building and Fire Prevention RESIDENTIAL RE -ROOF INSPECTION AFFIDAVIT NAILING, SHEATHING, DRY -IN, FLASHING, AND ALL FINAL ROOF COVERINGS ADDRESS: 103 Morrison Ave, Sanford. FL 32771 I Kristal A. Wingate , AS A(N) GENERAL, BUILDING, RESIDENTIAL, OR ROOFING CONTRACTOR, ENGINEER, ARCHITECT, OF F.S. CHAPTER 468 BUILDING INSPECTOR, I HEREBY AFFIRM, THAT ALL OF THE FOREGOING INFORMATION IS TRUE AND ACCURATE AND THAT ALL ROOFING COMPONENTS LISTED ON THE SCOPE OF WORK AT THE ABOVE REFERENCED ADDRESS HAVE BEEN INSTALLED IN ACCORDANCE WITH THEIR PRODUCT APPROVALS AND ALL APPLICABLE CODE REQUIREMENTS — SPECIFICALLY FLORIDA BUILDING CODE, EXISTING BUILDING. IN ADDITION I CERTIFY THE INSTALLATION MEETS ALL REQUIREMENTS FOR SECONDARY WATER BARRIER AND NAILING OF THE ROOF DECK, IN ACCORDANCE WITH THE HURRICANE RETROFIT MANUAL REQUIREMENTS (BASED ON F.S. CHAPTER 553.844). LICENSE#: CCC1326679 COMPANY/CONTRACTOR: CONTRACTOR SIGNATURE: a A , 0/c MUST BE SIGNED BY LICENSE HOLDER OR OWNERIBUILDER) A FINAL ROOF INSPECTION IS REQUIRED: DATE: 10-29-18 THIS SIGNED AND NOTARIZED AFFIDAVIT MUST BE PROVIDED AT THE JOB SITE AT THE TIME OF THE FINAL ROOF INSPECTION, ALONG WITH DIGITAL PHOTOGRAPHS OF EACH. PLANE OF THE ROOF SHOWING IN DETAIL ALL COMPONENTS (DECKING, UNDERLAYMENT, FLASHING, DRIP EDGE ATTACHMENT) WITH THE PERMIT NUMBER OR ADDRESS CLEARLY MARKED ON THE DECK FOR EACH INSPECTION. THE PHOTOGRAPHS MUST :INCLUDE A RULER OR MEASURING DEVICE TO CONFIRM ALL NAIL SPACING AND OVERLAPS, INCLUDING DRIP EDGE AND VALLEY FLASHING. PLEASE REFER TO THE RE -ROOF POLICY AND INSPECTION PROCEDURE PAPERWORK FOR FURTHER EXPLANATION OF ALL REQUIREMENTS. FAILURE TO FOLLOW ALL REQUIREMENTS WILL RESULT IN A FAILED INSPECTION, A RE -INSPECTION FEE AS WELL AS REQUIRING A DESIGN PROFESSIONAL (ARCHITECT OR ENGINEER) TO CERTIFY, BASED ON PERSONAL INSPECTION, THE INSTALLATION OF ALL ROOFING COMPONENTS. STATE OF FLORIDA COUNTY OF Seminole Sworn to and Subscribed before me this J6 day of O C7-' 2018 by: Kristal A. Wingate . Who is Cx Personally Known to me or has Produced (type of identification) Signature of Notary Pu State of Florida Deborah Plybon Print/Type/Stamp Name of Notary Public as identification. EE_ DEBORAH PLYBON Y.GOMNIISSION # GG 102302 EXPIRES: September 4,2021 ded Thru Notary Public Underwriters