Loading...
108 Westwood Ct - BR18-004340 - WINDOWS AND DOOR REPLACEMENTStreet: 820 E ALTAMONTE'DR Fax; 407-201-2278 City, State Zip;: ALTAmONTE SPRINGSFL 32701 Statelicense No.: CRC1.330822 Architect/Errgirieer Information Name-, _NIA Phone: Street:.,Fax: City, Sty, Zip:,, E-mail Bonding Company. N/A Mortgage Lender: Address:- Address WARNING TO OWNER: YOUR FAILURE TO RECORD A;:NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMLNTS TO VOUR PROPERTY. A NOTICE OF COMMENCEMENT 'MUST ?BE RECORDED AND POSTED, ON THE JOB SITE BEFORE THE FIRSTINSPECTION. IF-, YOU INTEND TO. OBTAIN FINANCING, CONSULT WITH. YOUR LENDER, OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT:, Application is hereby made to obtain a permit to do the work and installations as indicated. I ccrtify that no work or installation',has commenced prior to the issuance of a permit and that all work will ;;be 00formed to meet standards of.all laws regulating construction inthisjurisdiction. I understand that a separate permit must he secured far electrical work, plumbing,.. signs, wells, pools, furnaces, boilers, heatets,tanks, and air conditiouers„etc: FBG 105:3 Shall be inscribed with the date of application and the code in effect as of that date: 5t6 Edition (2014) Florida Building Code Revised: June 30, 201S Permit, Application management districts,, restrictions applicable to this property that may. be 1ired.:ft.0rh_otfi6r rngoVemental entities suc'h..as. water Acceotance of vermit is verification that I will notify the, owner of the property ofthe requirements of Florida Lien Law, FS -7,13 The City of Sanford requires payment o.f.'a plan review fee at theliffie"bf-pOftnit submittal. A copy of the executed contract is required: red in order to calculate a plan review. charge:and will be considered the 1. estimated construction value,of thejob, at the iime,of s'limittal, u Thie Actual cohstruction.valuc.will'be figured based on the current,,ICIC Valuation Table in effea-at the time the permit is issued; in Accordance with local, ordinance, ,Should calculated charges figured off the executed contract exceed the actual zebristiuctidn value, credit will be 'ied, issued. applied your permit fees when the permit is OWNER'S'. AFFIDAVIT: I certify 'llhat,all'of the foregoing infoemationis accurate and that all work will be done in compliance with all applicable. laws regulating construction and zoning. E. lr6-r.,;tWt!n b6tepergen ERIK JONES Notary Public - State of FloridaazCommission0FF920J409 My Comm. Expires Sep 21, 2019C Owner/Agent is, Personal y:.FnQwn tjWe,.or Prod Type of ID L"e" Produced 11) yp S71atu ofContraciortAgetit DX-7 I - , Ud Print Conkactor/Agcnt's Nome s afts ofNato ry-Sttiw of Floria DateipIu OS Millie Hawkins qIII V- 1 ok NOTARY PUBLICSTATEOFFLORIDA Comm# GG245440PV00CEis' Expires 8/5/2022 Contractor/Agent is" Personally Known4o.Me or Produced ID,- "Type of ID, Permits Required: Building Electrical-M Me chanicai 0 Plurh6ihg[I GasE] Roof Construction Type:, Occupancy Use: -Zone: Flood' Total. Sq Ft of Bldg,:_ 'Min.,Occupancy Load: ofStori&. New Construction: Electric - # of Amps Plumbing - # of Futures vsFire Sprifikleir Permit- Yes [] NoEl kof Heads Fite Alarm Perm - it: YesNo APPROVALS: ZONING:, UTILITIES,-- WASTE WATER:. ENGINEERINGBUILDING:; : FIRE, BUILDIN COMMENTS:, Revised: -June 30. 20 . 15 Pennit,APPfication REQUIMEIID INSP ECTI I JIlIllI t' 1 AA Il®IlIl ](D Il'Il It®IlIl. Footer / Setback Remwall ! Foundatioii / Form Board.'Survey Slab-/*M-ozio STab Pre our Lintel / Tie- Beam / Fill / Down Cell j Sheathing— 1- aHs' Sheathing'' Roof Roof Dry 111 Frame IInsulation Rough Tn Firewall Screw Pattern Drywall / Sheetrock jLath Ins : ection Final Solar ( Final Roof .I: Final Stucco / ,Siding Insulation Final Final Utility; Building' Final Door Final Window Final Screen.Room FinalPool Screen Enclosure' Mobile Home Building Final Pre: Demo Final Demo I Final' Single OamuTy,. Residence Final. Building Other i ( N- SIEQUIENCIE: Addiress: I i 1 J[nm max Isms 6,cdonDescri lido Electric. Underground F' ooter /' Slab Steel Bond Electrzc Rough T. U.G. Pre - Power Final Electric Final min Max 41 x "•dl 2:+_')1r. 'r,'. hnspe flom AD1{e sEEA:2floim Plumbing Underground Plumbing Sewer • . Plumbing Tub Set 1 Plumb'ingFinalI i p51{,,{.•'+ aC,':a::I/,1y`gAlx:.ji(j. iL'1.•4'MW*.xICI li1`714Orate..: L j.L;y:•.j,l.../'ry j iMnn Max I<Ms ec6m Desemfl tnom Mechanical Rough Mech. ancal. Final 1 II IlIl1M('}Y I I IlIls 1®m. ]ID s 1Cll $'Il m I Gas Underground - Gas Rough Gas. Final R EWS ED, June 2014 Grant Maloy, Clerk Of The Circuit Court & Comptroller Seminole County FL Inst #2018121389 Book:9236 Page:946; (1 PAGES) RCD: 10/22/2018 10:50:52 AM REC FEE $10.00 riY r(:1:s]lt a'II - NOTICE OF COMMENCEMENT State of Florida County of Seminole Permit Number: Parcel 0 Number. 12-20-30-501-0000-0590 The underelpned hereby elves notice that Improvement will be made to certain real property. and in accordance with Chapter 713. Florida Staknes, the following Infomwflon Is provided in this Notice of Commencement. DESCRIPTION OF PROPERTY: (Legal description of the property and street address if available) LOT 59 198 WESTWOOD CT MNFORD, FL 32773 SOUTH PINECREST 2ND ADD PB 10 PG 89 OF IMPROVEMENT: WINDOWS AND/OR DOORS SIZE FOR SIZE OWNER INFORMATION: Name: BALL, ELIZABETH K & JOHN C Address: 108 WESTWOOD CT SANFORD, FL 32773 Fee Simple Title NoMer (N other then ewer) flame: Address: CONTRACTOR: Name: Samuel Odvstein/New South Winnow Address: 820 E Altamonte Drive, Altamonte Springs, FL 32701 Persons within the She d Ftorids Designated by Owner upon whom notice or other docurnenis may be served as provided by Section 713.13(1)(b), Florida Stabdes. No": Address: in addition to himsW, Owner Designates To receive a copy ofthe Uenor's Notice as Provided in Section 713.13(1Xb), Florida StahAes. Expiration Daft of Notice of Commencement (The otplration dote is 1 year from date of recording unless a d9ter0et date is specftd) WARMIMQ TO OWNED ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART t, SECTION 713.13, FLORIDA STATUTES. AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY, A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST IMPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. Under penalties of perjury. I declare that I have read the foregoing and that the facts stated In It an tare to t1w4mat of my knowledge and belief. 11C-l? Owwa ow wrs PrYded Now R&IOs Rw to 713.1301tg> "The amw must sign fie nodts dcommrxwmitl end no one dse may be pa mlded to sego In his orher swad.' Stated Fk> w _County of 45e",wteje The foregolnil Insaument//was acknow N dged before me this _ day of k cicr S by El-'bC 1,,// C . Who Is personallyknown to me Name d person msMing etatemena OR who has produced Ideniffication type of ItleiLtication produced: _ I+ L +.' w f r e Se ERIK JONES Notary Public - Suit of Florida Cotnnllsslon a FF 920409 1„ My Comm. Expires Sep 21, 2010 eA _ D City oSanford Building and Fire Prevention Product Approval Specification Form Permit # Project Location Address PL As required by Florida Statute 553.842 and Florida Administrative Code 9N-3, please provide the information and product approval number(s) on the building components listed below if they are to be utilized on the construction project for which you are applying for a building permit. We recommend that you contact your local product supplier should you not know the product approval number for any of the applicable listed products. Be aware that windows, skylights, and exterior doors must be tested in accordance with the Florida Building Code, Section 1714.5. More information about Statewide Product Approval can be obtained at www.floridabuilding.org. The following information must be available on the jobsite for inspections: 1. This entire product approval form 2. A copy of the manufacturer's installation details and requirements for each product. Category / Subcategory Manufacturer Product Description Florida Approval # include decimal 1. Exterior Doors Swinging Sliding Sectional Roll Up Automatic Other 2. Windows Single Hun Horizontal Slider Casement Double Hun Fixed Awning Pass Through Projected Mullions Wind Breaker Dual Action Other June 2014 Category / Subcategory Manufacturer Product Description Florida Approval # including decimal 3. Panel Walls Siding Soffits Storefronts Curtain Walls Wall Louver Glass block Membrane Greenhouse E.P.S Composite Panels Other 4. Roofing Products Asphalt Shingles Underla ments Roofing Fasteners Nonstructural Metal Roofing Wood Shakes and Shingles Roofing tiles Roofing Insulation Waterproofing Built up roofing System Modified Bitumen Single Ply Roof Systems Roofing slate Cements/ Adhesives / Coating Liquid Applied Roofing Systems Roof Tile adhesive Spray Applied Polyurethane Roofing E.P.S. Roof Panels Roof Vents Other June 2014 Category/ Subcategory Manufacturer Product Description Florida Approval # include decimal 5. Shutters Accordion Bahama Colonial Roll up Equipment Other 6. Skylights Skylights Other 7. Structural Components Wood Connectors / Anchors Truss Plates Engineered Lumber Railing Coolers/Freezers Concrete Admixtures Precast Lintels Insulation Forms Plastics Deck / Roof Wall Prefab Sheds Other 8. New Exterior Envelope Products Applicant's Signature Applicant's Name LIL'Oe Please Print) June 2014 3 eau ut 820 East Altamonte Dr. aAltamdiRe Springs, FL 32701 407-261-2277 "407-261-2278 fax WINDOW so1.UT1ONS www.NewwpSouthWindow.com Made in the South forthe South. Date C_ /_;/ P To _4::_1;-7 a_ 1-, 4 .4 kl 9,o— E-mail c T rt a rr, 1 U! /"k C!+ Home Phone CellPhone c— —77? V 7y City cJ State F - Zipe V Business (1 . / Mrs.) 2)-J - b J (e"d Lr'- :/ Replacement Windows • Entry &Patio Doors . Storm Doors • Impact Resistant Windows & Doors WHOLESALE & RETAIL WINDOW CONTRACT NewSouth Window Solutionsaarees to measure, manufacture or furnish and service thefollowina custom made windows for the amount STIPULATED BELOW: All NewSouth Vantage Series Windows include Double Pane, LoE glass with Argon gas, and 12 point fusion welded corners. R eVantage windows are Sashlite'"'sealed andvacuum testedwith a foam, enhanced sash and frame. S? 99it ligfu!exterior onll G `' inL:dor Cob ,._ 7an Cotots mayvary sligtay horn sample 6niWq GW9ilionitwnolewinooh11eOTsn (h _ Y write in mbN OUANTITY OBSCURE GLASS YES LOCATION: ouAHn7r PVC COILTRLAA COLOR: TEMPEREDGLASS O YES LOCATION: NO wTLR1UTownscwpsAsYLLvnnwurcA0O5Lenroz mLL Li Vantage 7antage cl Mantage DOUBLE HUNG VANTAGE SERIES HALF - SCREEN) CASEMENT FULL XREENI onFullScreen2 LITESLIDER VANTAGE SERIES IHALF- SCREEN) DOUBLE CASEMENT TWO FULL SCREENSI i Full screen PICTURE INn SCREEN) F1WINDOWVANTAGE SERIES DOUBLECASEMENT WITH FIXED CENTER 3 LITE SLIDER PICTURE WINDOW AWNING & HOPPERTILT WINDOW IFULLSCnEENI VANTAGESERIES1 WOSCREENSI Cobr option al White or Tan only. PICTURE WINDOW WITH DOUBLE RUNGS PATIO DOORS O 5/0 a 6/e (591/7 a 791/2") 0 WE) x SM (/1 1 /2- X 791 /2") Indicate the WO X 8/0 (71 1/2- x 951/2-) VANTAGESERIESdirectionofslide08MX6/6 (95 V2- X 791/2-) IWOHALFSCREENS). I OXO DI OX 09/0 X(1/6 11071/2-X 791/2-) G HALF EYEBROW ,/mil GTRAP RAW SHAPEDWINDOWS (NOT FOAM ENHANCED) ROUND r IOTHERIN SPACE Ilj..._..i' J GRID STYLES Q STANDARD CONTOUR BRASS/GOLD/PENCIL Was thishome built prior to1978? Yes ElNo crlonlal Prafne. i O open Prahte If yes, the undersigned agress to the terms and conditions of the NewSouth Lead Safe Work Practices Addendum. e naiuR TOTAL NUMBER OF WINDOWS ON THIS ORDER: OTHER: Customer agrees tc allow New outh to display a yard sign until 30 days after completion. TWO YEARS FREE IN HOME SERVICE BUYER' S RIGHT TO CANCEL Total price' S rn BUYER MAY CANCEL THIS CONTRACT BY DELIVERING WRITTEN NOTICE TO THE SELLER AT ANY TIME PRIOR TO MIDNIGHT OF THE THIRD Down payment S BUSINESSDAYAFTERTHEDATEOFTHISTRANSACTION. BUYER MAY USE THIS CONTRACT AS THAT NOTICE.BY WRITING "I HEREBY CANCEL" AT. THE BOTTOM AND ADDING BUYER'S NAME AND ADDRESS..THE. Balance payable on NOTICE MUST BE DELIVERED TO THE SELLER ATTHE ADDRESS SHOWN Installation/Delivery S V 22 7 ABOVE. O Bank Financing +Gash on Completion All material is guaranteed to be as specified. All work is to be completed in a workmanlike manner according to standards and practices. This contract is valid only with proper signatures. NewSouth shall not be held responsible for time and material delays, strikes, acts of God or any other matters beyond its control. Owner agrees that the equity in this property is security for this contract. Since this contract calls for made to order goods, it is not subject to cancellation except as stated above. Start installation approximately weeks from above date. Verbal promises can cause misunderstandings, therefore this contract constitutes the entire understanding of the parties, and no other understanding, collateral, verbal or otherwise; shall be binding, unless signed by both parties. NewSouth to remove and haul away all job related debris. All sales and discounts allotted. All charges included above.Thank you for your order. x x Buy ig ture epresentative x x Buyer ignature NewSouth Manufacturing Authorized Officer 820 E. Altamonte Springs Dr. Altamonte Springs, FL, 32701ivewaouinPhone: (407) 261-2277 WINDOW OWTION Fax: (407) 261-2278 Contact Email : milliehawkins@newsouthwindow.com To Whom It May Concern: I, Samuel Ochstein, hereby authorize the following named person (s) to sign my name on my behalf to apply for and purchase permits for New South Window Solutions of Orlando. This list is to replace all others previously issued, which are now to be considered null and void. TYLER LEE FRED BROWN DAN FINK JUSTIN SHAW ELAINE LEWIS Job Address: 108 WESTWOOD CT SANFORD, FL 32771 Sincerely, Samuel Ochstein CRC1330822 State of Florida, County of _SEMINOLE Iq This foregoing instrument was acknowledged before me this J__L day of C - 2018, by Samuel Eli Ochstein, who is personally known to me and did not take an oath. otpRyAss Millie Hawkins aQ ° NOTARY PUBLIC STATE OF FLORIDA Comm# GG245440 ONCE 19 Expires 8/5/2022 MILLIE HAWKINS BiVAD_ Print name Notary Signature and seal Notes, RECORD COPY Window Spwiflcoonl and D+eUllf Purm-d to Convict wit, NewS A WMdDw SWuttons Cvstatier: H SrQ Y7 Sri y. ICj 1— t+1 a- First Floorrp pit CIA, vJ6i3If i> of wumracr tmae: rr - . _[ U eaynory Heg: /_ [ . tii P+- Custo 2r Approval: rarnes Screens Insu ' Gloms tkui tons TYPE aYrtnrLocationcelw t EXTANT M xHt Sates Memre iwxa4x_H__ 013 iin S" Make Size Z rx u x i xW S4. ko x (0 : x I x Jt REVIEWED FOR CODE COMPLIANCE 151= PLANS EXAMINER DATE iFQRD BUf DING DIVISION A PERMIT ISSUED SHALL BE CONSTRUED TO BE A LICENSE TO PROCEED WITH THE WORK AND NOT AS AUTHORITY TO VIOLATE, CANCEL, ALTER OR SET ASIDE ANY OF THE PROVISIONS OF THE TECHNICAL CODES, NOR SHALL ISSUANCE OF A PERMIT PREVENT THE BUILDING OFFICIAL FROM THEREAFTER REQUIRING A CORRECTION OF ERRORS IN PLANS, CONSTRUCTION OR VIOLATIONS OF THIS CODE S o 04 1t1EN1. 4,34 0 8/28/2018 , Florida Building Code Online 1ffiPONsnss ianal Regulatan BCIS Home I Log In I User Registration FI lida 11j, Product Approval USER: Public Userr I.W, o-'eap Hot Topics I Submit Surcharge I Stats & Facts I Publications Product Approval Menu > Product or Application Search > Application List > Application Detail FL # Application Type Code Version Application Status Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Florida Engineer or Architect Name who developed the Evaluation Report Florida License Quality Assurance Entity Quality Assurance Contract Expiration Date Validated By Certificate of Independence Referenced Standard and Year (of Standard) FL16842-R4 Revision 2017 Approved 9 NewSouth Window Solutions 4901 oak fair bivd tampa, FL 33610 513)284-0129 danochstein@newsouthwindow.com Vivian Wright rickw@rwbldgconsultants.com Windows Horizontal Slider Contact Us I B Evaluation Report from a Florida Registered Archii Professional Engineer u Evaluation Report - Hardcopy Received Lyndon F. Schmidt, P.E. PE-43409 National Accreditation and Management Institute 12/31/2018 Ryan 1. King, P.E. Validation Checklist - Hardcopy Received FL16842 R4 COI (c) Certificate of Independenc Standard AAMA/ W DMA/CSA 101/I. S. 2/A440 AAMA/W DMA/CSA101/I.S.2/A440 AAMA/W DMA/CSA101/I.S.2/A440 ASTM E1886 https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtmmTSTNdVPsf%2fLKgxApZZQumXyGur83s42hZkY3sC4ZA°/`3d%3d 1/6 8/28/2018 Florida Building Code Online ASTM E1996 ASTM E1996 ASTM E1996 TAS 201, 202, 203 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Summary of Products Go to Page [ a Method 1 Option D 04/ 11/2017 10/20/2017 10/23/2017 12/12/2017 FL # Model, Number or Name Description 16842.1 a. Series 9000 Model 9500 Slider XO Extruded Vinyl "Non -Impact" Horizont, Nail Fin Installation (XO or OX configu Limits of Use Installation Instructions Approved for use in HVHZ: No FL16842 R4 II (b) Inst 16842.1.pdf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 4 Impact Resistant: No Created by Independent Third Party: Design Pressure: N/A Evaluation Reports Other: See INST 16842.1 for Design Pressure Ratings, any FL16842_R4_AE (b) Eval 16842.1.pd additional use limitations, installation instructions and product Created by Independent Third Party: particulars. 16842.2 b. Series 9000 Model 9500 Slider XO Extruded Vinyl "Non -Impact" Horizont; Flange Installation (XO or OX configur. Limits of Use Installation Instructions Approved for use in HVHZ: No FL16842 R4 II (b) Inst 16842.2.)f Verified By: Lyndon F. Schmidt, P.E. 4ApprovedforuseoutsideHVHZ: Yes Impact Resistant: No Created by Independent Third Party: Design Pressure: N/A Evaluation Reports Other: See INST 16842.2 for Design Pressure Ratings, any FL16842 R4 AE (b) Eval 16842.2.pdd additional use limitations, installation instructions and product Created by Independent Third Party: particulars. 16842.3 c. Series 9000 Model 9550 Slider XO - Extruded Vinyl "Impact" Horizontal Sli Impact Rated Fin Installation (XO or OX configuratio Limits of Use Installation Instructions Approved for use in HVHZ: No FL16842 R4 II (b) Inst 16842.3.pdf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 4 Impact Resistant: Yes Created by Independent Third Party: Design Pressure: N/A Evaluation Reports Other: See INST 16842.3 for Design Pressure Ratings, any FL16842 R4 AE (b) Eval 16842.3.pd additional use limitations, installation instructions and product Created by Independent Third Party: particulars. 16842.4 d. Series 9000 Model 9550 Slider XO - Extruded Vinyl "Impact" Horizontal Sli, Impact Rated Installation (XO or OX configurations) Limits of Use Installation Instructions https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtmmTSTNdVPsf%2fLKgxApZZQumXyGur83s42hZkY3sC4ZA%3d%3d 2/6 8/28/2018 Florida Building Code Online Approved for use in HVHZ: No FL16842 R4 II (b) Inst 16842.4.pdf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 4 Impact Resistant: Yes Created by Independent Third Party: Design Pressure: N/A Evaluation Reports Other: See INST 16842.4 for Design Pressure Ratings, any FL16842 R4 AE (b) Eval 16842.4.pd Created by Independent Third Party: additional use limitations, installation instructions and product particulars. 16842.5 e. Series 9000 Model 9550 Slider XO - Extruded Vinyl "Impact" Horizontal Sli Impact Rated - HVHZ Fin Installation (XO or OX configuratio Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL16842 R4 II (b) Inst 16842.5.pdf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 4 Impact Resistant: Yes Created by Independent Third Party: Design Pressure: N/A Evaluation Reports Other: See INST 16842.5 for Design Pressure Ratings, any FL16842 R4 AE (b) Eval 16842.5.pd additional use limitations, installation instructions and product Created by Independent Third Party: particulars. 16842.6 f. Series 9000 Model 9550 Slider XO - Extruded Vinyl "Impact" Horizontal Sli, Impact Rated - HVHZ Installation (XO or OX configurations) Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL16842 R4 II (b) Inst 16842.6.pdf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 4 Impact Resistant: Yes Created by Independent Third Party: Design Pressure: N/A Evaluation Reports Other: See INST 16842.6 for Design Pressure Ratings, any FL16842 R4 AE (b) Eval 16842.6.pd additional use limitations, installation instructions and product Created by Independent Third Party: particulars. 16842.7 g. Series 9000 Model 9500-3 Slider Extruded Vinyl "Non -Impact" Horizont, XOX Nail Fin Installation (XOX, configuratio Limits of Use Installation Instructions Approved for use in HVHZ: No FL16842 R4 II (b) Inst 16842.7.if Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 4 Impact Resistant: No Created by Independent Third Party: Design Pressure: N/A Evaluation Reports Other: See INST 16842.7 for Design Pressure Ratings, any FL16842 R4 AE (b) Eval 16842.7.pd additional use limitations, installation instructions and product Created by Independent Third Party: particulars. 16842.8 h. Series 9000 Model 9500-3 Slider Extruded Vinyl "Non -Impact" Horizont; XOX Flange Installation (XOX, configuratior Limits of Use Installation Instructions Approved for use in HVHZ: No FL16842 R4 II (b) Inst 16842.8.pdf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 4 Impact Resistant: No Created by Independent Third Party: Design Pressure: N/A Evaluation Reports Other: See INST 16842.8 for Design Pressure Ratings, any FL16842 R4 AE (b) Eval 16842.8.pdd additional use limitations, installation instructions and product Created by Independent Third Party: particulars. 16842.9 i. Series 9000 Model 9550-3 Slider Extruded Vinyl "Impact" Horizontal Sli, XOX - Impact Rated Fin Installation (XOX, configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No FL16842 R4 II (b) Inst 16842.9.pdf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 4 Impact Resistant: Yes Created by Independent Third Party: Design Pressure: N/A Evaluation Reports Other: See INST 16842.9 for Design Pressure Ratings, any FL16842 R4 AE (b) Eval 16842.9.pd additional use limitations, installation instructions and product Created by Independent Third Party: particulars. 16842.10 j. Series 9000 Model 9550-3 Slider Extruded Vinyl "Impact" Horizontal Slip https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtmmTSTNdVPsf%2fLKgxApZZQumXyGur83s42hZkY3sC4ZA%3d%3d 3/6 8/28/2018 Florida Building Code Online XOX - Impact Rated Installation (XOX, configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No FL16842 R4 II (b) Inst 16842.10.pd Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 4 Impact Resistant: Yes Created by Independent Third Party: Design Pressure: N/A Evaluation Reports Other: See INST 16842.10 for Design Pressure Ratings, any FL16842 R4 AE (b) Eval 16842.10.p additional use limitations, installation instructions and product Created by Independent Third Party: particulars. 16842.11 k. Series 9000 Model 9550-3 Slider Extruded Vinyl "Impact" Horizontal Sli XOX - Impact Rated - HVHZ Fin Installation (XOX, configuration) Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL16842 R4 II (b) Inst 16842.11.pd Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 4 Impact Resistant: Yes Created by Independent Third Party: Design Pressure: N/A Evaluation Reports Other: See INST 16842.11 for Design Pressure Ratings, any FL16842 R4 AE (b) Eval 16842.11.p additional use limitations, installation instructions and product particulars. Created by Independent Third Party: 16842.12 I. Series 9000 Model 9500-3 Slider Extruded Vinyl "Impact" Horizontal Sli, XOX - Impact Rated - HVHZ Installation (XOX, configuration) Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL16842 R4 II (b) Inst 16842.12.pd Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 4 Impact Resistant: Yes Created by Independent Third Party: Design Pressure: N/A Evaluation Reports Other: See INST 16842.12 for Design Pressure Ratings, any FL16842 R4 AE (b) Eval 16842.12.p additional use limitations, installation instructions and product Created by Independent Third Party: particulars. 16842.13 m. DuraGard Slider XX Extruded Vinyl "Non -Impact" Horizont; Nail Fin Installation (XX, configuration Limits of Use installation Instructions Approved for use in HVHZ: No FL16842 R4 II (b) Inst 16842.13.pd Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 4 Impact Resistant: No Created by Independent Third Party: Design Pressure: N/A Evaluation Reports Other: See INST 16842.13 for Design Pressure Ratings, any FL16842 R4 AE (b) Eval 16842.13.p additional use limitations, installation instructions and product Created by Independent Third Party: particulars. 16842.14 In. DuraGard Slider XX Extruded Vinyl "Non -Impact" Horizont: configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No FL16842 R4 II (b) Inst 16842.14.pd Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 4 Impact Resistant: No Created by Independent Third Party: Design Pressure: N/A Evaluation Reports Other: See INST 16842.14 for Design Pressure Ratings, any FL16842 R4 AE (b) Eval 16842.14.p additional use limitations, installation instructions and product Created by Independent Third Party: particulars. 16842.15 o. DuraGard - 3 Slider XOX Extruded Vinyl "Non -Impact" Horizont; Nail Fin Installation (XOX, configuratio Limits of Use Installation Instructions Approved for use in HVHZ: No FL16842 R4 II (j2) Inst 16842.15.pd Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 4 Impact Resistant: No Created by Independent Third Party: Design Pressure: N/A Evaluation Reports Other: See INST 16842.15 for Design Pressure Ratings, any FL16842 R4 AE (b) Eval 16842.15.p Created by Independent Third Party: https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtmmTSTNdVPsf%2fLKgxApZZQumXyGur83s42hZkY3sC4ZA%3d%3d 4/6 Florida Building Code Online additional use limitations, installation instructions and product particulars. 16842.16 p. DuraGard - 3 Slider XOX Extruded Vinyl "Non -Impact" Horizont, Flange Installation (XOX, configuratior Limits of Use Installation Instructions Approved for use in HVHZ: No FL16842 R4 II (b) Inst 16842.16.pd Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 4 Impact Resistant: No Created by Independent Third Party: Design Pressure: N/A Evaluation Reports Other: See INST 16842.16 for Design Pressure Ratings, any FL16842 R4 AE (b) Eval 16842.16.p additional use limitations, installation instructions and product Created by Independent Third Party: particulars. 16842.17 q. Sashlite Slider XX Extruded Vinyl "Non -Impact" Horizont; Nail Fin Installation (XX, configuration Limits of Use Installation Instructions Approved for use in HVHZ: No FL16842 R4 II (b) Inst 16842.17.pd Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 4 Impact Resistant: No Created by Independent Third Party: Design Pressure: N/A Evaluation Reports Other: See INST 16842.17 for Design Pressure Ratings, any FL16842 R4 AE (12) Eval 16842.17.p additional use limitations, installation instructions and product Created by Independent Third Party: particulars. 16842.18 r. Sashlite Slider XX Extruded Vinyl "Non -Impact" Horizont; configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No FL16842 R4 II (2) Inst 16842.18.pd Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 4 Impact Resistant: No Created by Independent Third Party: Design Pressure: N/A Evaluation Reports Other: See INST 16842.18 for Design Pressure Ratings, any FL16842 R4 AE (b) Eval 16842.18.p additional use limitations, installation instructions and product Created by Independent Third Party: particulars. 16842.19 s. Sashlite - 3 Slider XOX Extruded Vinyl "Non -Impact" Horizont; Nail Fin Installation (XOX, configuratio Limits of Use Installation Instructions Approved for use in HVHZ: No FL16842 R4 II (b) Inst 16842.19.pd Verified By: Lyndon F. Schmidt, P.E. 4ApprovedforuseoutsideHVHZ: Yes Impact Resistant: No Created by Independent Third Party: Design Pressure: N/A Evaluation Reports Other: See INST 16842.19 for Design Pressure Ratings, any FL16842 R4 AE (b) Eval 16842.19.p additional use limitations, installation instructions and product Created by Independent Third Party: particulars. 16842.20 t. Sashlite - 3 Slider XOX Extruded Vinyl "Non -Impact" Horizont, configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No FL16842 R4 II (b) Inst 16842.20.pd Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 4 Impact Resistant: No Created by Independent Third Party: Design Pressure: N/A Evaluation Reports Other: See INST 16842.20 for Design Pressure Ratings, any FL16842 R4 AE (2) Eval 16842.20.p Created by Independent Third Party: additional use limitations, installation instructions and product particulars. Go to Pagerr j Back Next https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtmmTSTNdVPsf%2fLKgxApZZQumXyGur83s42hZkY3sC4ZA%3d%3d 5/6 8/28/2018 Florida Building Code Online Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Qgpyjjght 2007-2013 State of Florida.:: Privacy Statement :: Accessibility !S Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a pub electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please cor Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the I if they have one. The emails provided may be used for official communication with the licensee. However email addresses are to supply a personal address, please provide the Department with an email address which can be made available to the pL licensee under Chapter 455, F.S., please click here . Product Approval Accepts: F90-1 9 M P i6c, :itJ A+61 [ 's r fi. P =_ https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtmmTSTNdVPsf%2fLKgxApZZQumXyGur83s42hZkY3sC4ZA%3d%3d 6/6 EPWINDOWSOLUTIONS M III ewSouth V\ 4901 OakFairBlvd., Tampa, FL 33610 DuraGard Slider XX WO N-'IYIml. rr GENERAL NOTES 1. This product has been evaluated and is in compliance with the 6th Edtion (2017) Roddo Building Code (FBC) structural requirements excluding the "High Velocity Hurricane Zone' HVHZ). 2. Productanchors shall beas fisted and spaced asshown on details. Anchorembedment to base material shall be beyond wall dressing or stucco. 3. When used in areas requiring wind borne debris protection this product is required to be protected with an impact resistant covering that complies with FBC Sections 1609.1.2 & R301.2.1.2. 4. For 2x stud framing construction, anchoring of these units shall be the some as that shown for 2x buck masonry construction. 5. Site conditions thatdeviate from the details ofthis drawing require furtherengineering analysis by a licensed engineeror registered architect. TABLE OF CONTENTS SHEET# DESCRIPTION 1 Typical elevations, design pressures & general notes 2 Vertical & horizontal cross sections 3 Vertical & horizontal cross sections 4 Buck & frame anchoring 5 Bill of materials, glazing details and components FRAME WIDTH 1 DESIGNRRESSURE FRAME DIMENSION DAY'UGHi DIMENSION G(ASS TYPE 72.0" x 65.0" 32.56" x 511.S" Gt 30.0 30.0 72.0" x 56.0" 32.56" x 49.5" Gl 35.0 35.0 Imo'/'•• y J'mWM) 000 N Ew Z.p Z8mu O o 3a L m a 4 m Gi a W z0 Q c WS d SCALE: N.T'.S. MG. BY: JK CHK. BY: LFS DRAWNG NO.: FL-16842.14 SHEET 1 OF S D Z i NOTE: Sheet MetalScrews must penetrate a D ts 1` A L min. of 3 threads through at least 2 sheets ofX mg 4_0 1 metal (maintain a min. 3/6' edge distance). J' ci ro C INTERIOR n cz 4m roEc a °' zoUN B t S i c=o X X 8 ua 9m`ao 1 o C v o a Na maa12 2 E a K M 1 LL EXTERIOR o No Z 3 OU 2 3 HORIZONTAL CROSS SECTION 2 2 Steel Stud Construction Z m .y G1 N u U q 1-IIN' MIN. EXTERIOR INTERIOR I o 6 IJv1B. RrPJ o a a V s" g C 1 3 2 UU J mT a 6 T1 O.:.O Q- EJ nv NN 14 g WW rn oZ is ill N y o CaQINTERIOR w F G1 AzzzEXTERIOR w Gl o° DATE: 3120112a3DEc oSCAE: N.T.S. 3 E Z a owc. er: JK m 0H1• e1 1 HORIZONTAL CROSS SECTION D 2 VERTICAL CROSS SECTION m OiUWINC NO.: FL-16842.14 a 2 2X Buck Masonry ConstructionZ Z 2X Buck Masonry Construction w i h SHEET _L OF $ A D / X X d' oE . .. da a i '•. % f. e1 ro G A Z rar p * 11'. Z o 'm o 8 C U N ZJ 711 Z l C Rj 8 E.9 mcWupoo. o m maa2Km a v , ui 0 El j o d 3 2 ItzV) NO G1 ^ o F J ,) 2 3 EXTERIOR INTERIOR o w vN 3 3 t I VERTICAL CROSS SECTION o `er' 3 a EXTERIOR INTERIOR 0 EXTERIOR INTERIOR a a 5 m 3 2 3 2 E? o 3 0 0 o o 8 W. o 1 Q oa o El oE Sd d E a w i a N N Q j d DATE. 3120112 z 0 sca.E: N.T.S. 5 DWG. BY. JK m 2 VER17CAL CROSS SECTION r 3 VERTICAL CROSS SECTION Gwc. ar: LFS 3 Masonry s0 v Masonry sill IXUWING No.: rc FL-16842.14 0n sNEEr 3 ov 5 2X SUB BUCK MASONRY OPENING 4" TYP.) 4 (TYP•) 2X BUCK ANCHORING 8iL a CONCRETE ANCHOR NOTES: 0 1. Concrete anchor locations at the comers may be ocyusted to mofntatn the mfn. edge distance to mcdarjolnts. 2. Concrete anchor locations noted as "MAX. ON CENTER' musf be ocFXsted to Z maintain the min. edge distance to mortarjoints, addtionalconcrete anchors Z may be mgL*edtoenswe the "MAX. ONCENTER' dhnenston are notexceeded. a 3. Concrete anchor table: o m WOODSCREW INSTALLATION NOTES: z 1. Maintain aminimum 5/8' edge dMance. 1"enddistance, & I"o.c. spacing of woodscrews to prevent the splittingofwood. ANCHOR ANCHOR.'MIN. CLEARANCE N. CLEARANCE. TYPE SIZE EMBEDMENT 70 MASONRY 76 ADJACS ANCHOR. .: rrW TAPCON ELCO aULTRACON 1/4' 1-1/P 1' 4' i R h U 6 O c s . F — N TYP.) rT i T\\\ o nUN• 8(flP.) ^ v -- i Em zSeo FRAME 2X SUB BUCK MASONRY OPENING F 2X BUCK G 1XBUCK L STEEL STUD TYP. FRAME ANCHORING ro e yg 9otavoa " maaT i EE'L az a. a ALE N.T.S. VC. BY: JK m W. ar: LFS 3 NO NO.: [C FL-16842.14 0 im 4 of 5 " A BILL OF MATERIALS rrEM3 mcRIPTR7N MATERW A 1 X BUCK (SG >= 0.42) WOOD B 2X BUCK (SG >= 0.42) WOOD C 1 /4" MAX. SHIM SPACE D 1 /4" X 2-3/4" PFH ELCO OR ITW CONCRETE SCREW STEEL E MASONRY - 3,000 PSI MIN. CONCRETE CONFORMING TO ACI 301 OR HOLLOW BLOCK CONFORMING TO ASTM C90 CONCRETE F 10 X7' PPH SMS (1-1/7' MIN. EMBEDMENT) STEEL G 1 /4" X 23/4" HH ELCO OR ITW CONCRETE SCREW WOOD K 6 X 1-1/4" PFH SMS STEEL L 10 PPH SELF -DRILLING SMS STEEL X STEEL STUD Min. Thk .033" (ASTM A653 GRADE 33 Fr33 Id min., Fu=45 W min.) STEEL 1 FRAME PVC 2 SASH' PVC 3 GLAZING BEAD' PVC 4 GLASS SETTING BLOCK PVC 5 PULL STILE* PVC 6 LOCK STILE' PVC 7 MEETING STILE' PVC 8 ANTI -LIFT & SILL TRACK` 10 GLAZING SILICONE (DOW 11991 jjAgLUM1411REINFORCEMENT (6063 - T5) LOCK ASSEMBLY (TRUTH) THE APPROVED WHITE RIGID PVC EXTERIOR EXTRUSIONS FOR WINDOWS ARE TO BE PRODUCED BY EXTRUDERS LICENSEES IN "AAMA CERTIFICATION PROGRAMS FOR RIGID PVC EXTRUSIONS". 7/8" O.A. GLASS THK. 1/8"ANNEALED GLASS AIR SPACE 1 /8" ANNEALED GLASS R Gl GLAZING DETAIL 9 fn o- I 0.22' 0.05' 0.56" GLAZING BEAD 446E FRAME 444F 0.93" -(---1 1" 6 LOCK S71LE494E 1.23" - l F- I 0.09" REINFORCEMENT 480 1 O F . 48" L I I- 0.07' 8 ANT1.UFTRSILL TRACK206 0.28 -1 a 1` O O 2 SASH424E 0.9• 5 PULL SnLE4753 Off. •• •• t'_ nn i N''• g O: °o Y.. ` Fran n z N O E\\ V g E m z v o c ) 9 a. NQro mOtmda au: E oz d . w cV MEETING w 493B rc. BY. JK IK. BY: LFS ; CAWING NO.: a, FL-16842.14 c d IEEE 5 OF 5 Q 9/28/2018 r Florida Building Code Online BCIS Home I Log In I User Registration I Hot Topics I Submit Surcharge I Scats & Facts I Publications ( Contact Us ' BCIS Site Map I Links I Search b a ry jl ; ;Product Approval qq { USER: Public User tt iti;Fxm Product Approval Menu > Product or Application Search > Application List > Application Detail FL # Application Type Code Version Application Status Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method FL16842-R4 Revision 2017 Approved 0 NewSouth Window Solutions 4901 oak fair blvd tampa, FL 33610 513)284-0129 danochstein@newsouthwindow.com Vivian Wright rickw@rwbldgconsultants.com Windows Horizontal Slider Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer O Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Lyndon F. Schmidt, P.E. Evaluation Report Florida License PE-43409 Quality Assurance Entity National Accreditation and Management Institute Quality Assurance Contract Expiration Date 12/31/2019 Validated By Ryan 1. King, P.E. U Validation Checklist - Hardcopy Received Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By FL16842 R4 COI (c) Certificate of independence.pdf Standard Year AAMA/ W DMA/CSA 101/I. S.2/A440 2008 AA MA/ W DMA/CSA 101/I. S.2/A440 2005 AAMA/ W DMA/CSA 101/I. S. 2/A440 2011 ASTM E1886 2005 ASTM E1996 2006 ASTM E1996 2005 ASTM E1996 2009 TAS 201, 202, 203 1994 https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtmmTSTNdVPsf°/a2fLKgxApZZQumXyGur83s42hZkY3sC4ZA%3d%3d 1/5 9/28/2018 Sections from the Code Florida Building Code Online Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Summary of Products Go to Page = Method 1 Option D 04/11/2017 10/20/2017 10/23/2017 12/12/2017 Page 1 / 20 0 FL # Model, Number or Name Description 16842.1 a. Series 9000 Model 9500 Slider XO Extruded Vinyl "Non -Impact" Horizontal Sliding Window utilizing a Nail Fin Installation (XO or OX configurations) Limits of Use Installation Instructions Approved for use in HVHZ: No FL16842 R4 II (b) Inst 16842.1.pd Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 16842.1 for Design Pressure Ratings, any FL16842 R4 AE (b) Eval 16842.1.q f additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. 16842.2 b. Series 9000 Model 9500 Slider XO Extruded Vinyl "Non -Impact" Horizontal Sliding Window with Flange Installation (XO or OX configurations) Limits of Use Installation Instructions Approved for use in HVHZ: No FL16842 R4 II (b) Inst 16842.2&df Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 16842.2 for Design Pressure Ratings, any FL16842 R4 AE (b) Eval 16842.2.12df additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. 16842.3 c. Series 9000 Model 9550 Slider XO Extruded Vinyl "Impact' Horizontal Sliding Window utilizing a Impact Rated Nail Fin Installation (XO or OX configurations) Limits of Use Installation Instructions Approved for use in HVHZ: No FL16842 R4 II (b) Inst 16842.3.pdf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 16842.3 for Design Pressure Ratings, any FL16842 R4 AE (b) Eval 66842.3.pdf additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. 16842.4 d. Series 9000 Model 9550 Slider XO Extruded Vinyl "Impact' Horizontal Sliding Window with Flange Impact Rated Installation (XO or OX configurations) Limits of Use Installation Instructions Approved for use in HVHZ: No FL16842 R4 II (b) Inst 16842.4.pdf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 16842.4 for Design Pressure Ratings, any FL16842 R4 AE (b) Eval 16842.4.pdf additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. 16842.5 e. Series 9000 Model 9550 Slider XO Extruded Vinyl "Impact' Horizontal Sliding Window utilizing a Impact Rated - HVHZ Nail Fin Installation (XO or OX configurations) Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL16842 R4 II (b) Inst 16842.5.Qf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant. Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 16842.5 for Design Pressure Ratings, any FL16842 R4 AE (b) Eval 16842.5.pdf additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. 16842.6 f. Series 9000 Model 9550 Slider XO Extruded Vinyl "Impact' Horizontal Sliding Window with Flange Impact Rated - HVHZ Installation (XO or OX configurations) hftps://www.floridabuilding.org/prlpr_app_dtl.aspx?param=wGEVXQwtDgtmmTSTNdVPsf%2fLKgxApZZQumXyGur83s42hZkY3sC4ZA%3d°/`3d 2/5 9/28/2018 Florida Building Code Online Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL16842 R4 II (b) Inst 16842.6.pdf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 16842.6 for Design Pressure Ratings, any FL16842 R4 AE (b) Eval 16842.6.gdf additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. 16842.7 g. Series 9000 Model 9500-3 Slider Extruded Vinyl "Non -Impact' Horizontal Sliding Window XOX utilizing a Nail Fin Installation (XOX, configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No FL16842 R4 II (b) Inst 16842.7.pdf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 16842.7 for Design Pressure Ratings, any FL16842 R4 AE (b) Eval 16842.7.pdf additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. 16842.8 h. Series 9000 Model 9500-3 Slider Extruded Vinyl "Non -Impact" Horizontal Sliding Window with XOX Flange Installation (XOX, configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No FL16842 R4 II (b) Inst 16842.8.pdf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 16842.8 for Design Pressure Ratings, any FL16842 R4 AE (b) Eval 16842.8.pdf additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. 16842.9 i. Series 9000 Model 9550-3 Slider Extruded Vinyl "Impact' Horizontal Sliding Window utilizing a XOX - Impact Rated Nail Fin Installation (XOX, configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No FL16842 R4 II (b) Inst 16842.9.pdf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 16842.9 for Design Pressure Ratings, any FL16842 R4 AE (b) Eval 16842.9.pdf additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. 16842.10 j. Series 9000 Model 9550-3 Slider Extruded Vinyl "Impact' Horizontal Sliding Window with Flange XOX - Impact Rated Installation (XOX, configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No FL16842 R4 II (b) Inst 16842.10.pdf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 16842.10 for Design Pressure Ratings, any FL16842 R4 AE (b) Eval 16842.10.pdf additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. 16842.11 k. Series 9000 Model 9550-3 Slider Extruded Vinyl "Impact' Horizontal Sliding Window utilizing a XOX - Impact Rated - HVHZ Nail Fin Installation (XOX, configuration) Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL16842 R4 II (¢) Inst 16842.1i,pdf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 16842.11 for Design Pressure Ratings, any FL16842 R4 AE (12) Eval 16842.11.pdf additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. 16842.12 I. Series 9000 Model 9500-3 Slider Extruded Vinyl "Impact' Horizontal Sliding Window with Flange XOX - Impact Rated - HVHZ Installation (XOX, configuration) Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL16842 R4 II (b) Inst 16842.12.pdf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 16842.12 for Design Pressure Ratings, any FL16842 R4 AE (b) Eval 16842.12.pdf additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. 16842.13 m. DuraGard Slider XX Extruded Vinyl "Non -Impact' Horizontal Sliding Window utilizing a Nail Fin Installation (XX, configuration) https://www.floridabuilding.org/prlpr_app_dti.aspx?param=wGEVXQwtDgtmmTSTNdVPsf%2fLKgxApZZQumXyGur83s42hZkY3sC4ZA°/"3d%3d 3/5 9/28/2018 Florida Building Code Online Limits of Use Installation Instructions Approved for use In HVHZ: No FL16842 R4 II (b) Inst 16842.13.pdf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 16842.13 for Design Pressure Ratings, any FL16842 R4 AE (b) Eval 16842.13.pdf additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. 16842.14 n. DuraGard Slider XX Extruded Vinyl "Non -Impact' Horizontal Sliding Window (XX, configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No FL16842 R4 II (11) Inst 16842.14.pdf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 16842.14 for Design Pressure Ratings, any FL16842 R4 AE (b) Eval 16842.14.pdf additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. 16842.15 o. DuraGard - 3 Slider XOX Extruded Vinyl "Non -Impact' Horizontal Sliding Window utilizing a Nail Fin Installation (XOX, configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No FL16842 R4 II (b) Inst 16842.15.pdf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 16842.15 for Design Pressure Ratings, any FL16842 R4 AE (b) Eval 16842.15.pdf additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. 16842.16 p. DuraGard - 3 Slider XOX Extruded Vinyl "Non -Impact' Horizontal Sliding Window with Flange Installation (XOX, configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No FL16842 R4 II (b) Inst 1 8842.16.pdf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 16842.16 for Design Pressure Ratings, any FL16842 R4 AE (b) Eval 16842.16.pdf additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. 16842.17 q. Sashlite Slider XX Extruded Vinyl "Non -Impact' Horizontal Sliding Window utilizing a Nail Fin Installation (XX, configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No FL16842 R4 II (b) Inst 16842.17.pdf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 16842.17 for Design Pressure Ratings, any FL16842 R4 AE (b) Eval 16842.17.pdf additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. 16842.18 r. Sashlite Slider XX Extruded Vinyl "Non -Impact" Horizontal Sliding Window (XX, configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No FL16842 R4 II (b) Inst 16842.18.pdf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 16842.18 for Design Pressure Ratings, any FL16842 R4 AE (b) Eval 16842.18.pgf additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. 16842.19 s. Sashlite - 3 Slider XOX Extruded Vinyl "Non -Impact' Horizontal Sliding Window utilizing a Nail Fin Installation (XOX, configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No FL16842 R4 II (b) Inst 16842.19.pdf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 16842.19 for Design Pressure Ratings, any FL16842 R4 AE (b) Eval 16842.19.pdf additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. 16842.20 t. Sashlite - 3 Slider XOX Extruded Vinyl "Non -Impact' Horizontal Sliding Window (XOX, configuration) https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtmmTSTNdVPsf%2fLKgxApZZQumXyGur83s42hZkY3sC4ZA%3d%3d 4/5 9/28/2018 Florida Building Code Online Limits of Use Installation Instructions Approved for use in HVHZ: No FL16842 R4 II (¢) Inst 16842.20.E Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 16842.20 for Design Pressure Ratings, any FL16842 R4 AE (b) Eval 16842.20.pdf additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. Go to Page Back Next 0® Page l/ 2 0 0 Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. QgpYLght 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. -Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. if you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: 0hsck eS . 0 Safe sechu'Itynt L- ucs^ ; hftps://www.floridabuilding.org/prlpr_app_dtl.aspx?param=wGEVXQwtDgtmmTSTNdVPsf%2fLKgxApZZQumXyGur83s42hZkY3sC4ZA%3d%3d 5/5 W S 0 UIt 1 FEWINDOWSOLUTIONS 4901 Oak Fair Blvd., Tampa, FL 33610 DvraGard - 3 Slider XOX NON -IMPACT" GENERAL NOTES 1. This product has been evaluated and is in compliance with the 6th Edition 2017) Florida Building Code (FBC) structural requirements excluding the High Velocity Hurricane Zone" (HVHZ). 2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment to base material shall be beyond wall dressing or stucco. 3. When used in areas requiring wind bome debris protection this product is required to be protected with an impact resistant covering that complies with FBC Sections 1609.1.2 & R301.2.1.2. 4. For 2x stud framing construction, anchoring of these units shall be the some as that shown for 2x buck masonry construction, 5. Site conditions that deviate from the details of this drawing require further engineering analysis by a licensed engineer or registered architect. TABLE OF CONTENTS SHEET# DESCRIPTION I Typical elevations, design pressures & general notes 2 Horizontal and vertical cross sections 3 Buck & frame anchoring 4 Bill of materials, glazing details and components 11 T MAX. OVERALL FRAME WIDTH X 0 X MAX. DAYLGNL.. MAXDAYLIGHT DESIGN PRESSURE FRAME' DIMENSION . OPENING DIMENSION OPENING DIMENSION GLASS; TYPE, PSG F:(OPERABLE). 112.0" x 63.25" 52.25" x 56.5' 25.5' x S6.5" G1 30.0 30.0 It 111111/ r i Q-_ Ja n a:o oW it/rr 1*11 11 z o zip o U.N ..Z n N v Z O Z UE Gt 9m opLC WmgmaLai x 4 E ofoq4i3 ca 2 NIn N N Q I m N z L z c TE: 4 17 12 i ALE: N.T.S. G. BY: JK K. BY: LFS 3 AWING NO:: FL-16842.16 A Err _L of 4 11111 flit 4 F1_' M Z nIt2Ea . Z loin 1 A Z ism C f o X F Eag _imoo 0 qz 9 d 'a a22o` v!a aa 22 zav . 23 p 10 8 `la: 7 aU V) O 2W3JYJ2VERMALCROSSSECTION2JV) 2 IX Buck Masonry Construction N vi ~O 1-1/4" MIN. B EXTERIOR INTERIOR o x NL) rccc EMB. FYP.) o Ir G1 a a m C 20 B 1 3 INTERIOR GI 4 6 a a 11 00 12 1 N N u, W W p Q El25 17 C G m G m oo 26 F D E oe m F EXTERIOR a. N _ oZ E D 5 12 6 a. 4. aTE: 4117112 = o SCALE N.T.S. 5 2 DWG. BY. JK m1HORIZONTALCROSSSECTION3VERTICALCROSSSECTIONCHK. BY.. LFS 3Q2XBuckMasonryConstruction22XBuckMasonryConstructionDRAWMCNO.: Y FL-16842.16 0 N SHEET _L OF ¢ S o n MTG. RAIL X. Jllfit 11 mon zo gr 9mcowa n Ma:a. ZX SUB V a LL d E v W BUCK A MASONRY Ic OPENING o w F En V m N U3ZN Q O m MTG. RAIL s 1XBUCKANCHORING p' jTYP.) P• —I j m yP) s Uu aua 11Ty ox O o NoCCpWWZO e tN FRAME a o W O CONCRETE ANCHOR NOTES: v I. Concrete anchor locations at the comers may be adjusted to maintain the min. MASONRY j j z mN M edge distance tomodarlofnts. OPENING q 2. Concrete anchor locations ratedas "MAX. ONCENTER" must beadjustedto Z maintain the min edge distance to mortar joints, oddttonol concrete anchors may be required to ensure the "MAX. ON CENTER" dimension ore not exceeded. 3. Concrete anchor table: z O oNzZa DATE, 4117112 i scnsE N.T.S. rwV 3 ovrc. BY: JK m FRAME ANCHORING 3DMncNO, LFS WOOD SCREW INSTALLATION NOTES: FL-16842.16 ro1. Maintain a minimum5/B"edge distance, 1"end distance, d I"o.c. spacingof p SHEET 3 pF ¢ wwoodscrewstopreventthesplitsingofwood. 1YP 4" iYP, Tl'P. TYP.) O ANCHOR ANCHOR M1N MIN CLEARANCE MIN: CLEARANCE TYPE SIZE FMBEDMENT ZTD MASONRY 10 ADJACFM ;;- r EDGE-..;:: ANCHOR TAPCON ELCO e 1 4" 1-1/4" 1" 4' UITRACON VIF2XKK TYP I I I I I BILL OF MATERIALS NFM # DESCRIPTION MATERIAL A iX BUCK (SG >= 0.42) WOOD B 2X BUCK (SG >= 0.42) WOOD C I /4" MAX. SHIM SPACE D 1 /4" X 2-3/4"PFH ELCO OR ITW CONCRETE SCREW STEEL E MASONRY - 3,000 PSI MIN. CONCRETE CONFORMING TO ACI 301 OR HOLLOW BLOCK CONFORMING TO ASTM C90 CONCRETE F 10 X 2-1/7' PPH SMS (1-3/8" MIN. EMBEDMENT) STEEL H 1 /4" X 3-1 /4" PFH ITW CONCRETE SCREW STEEL 1 EXTRUDED VINYL FRAME. (444) RIGID PVC 2 EXTRUDED VINYL FLANGE INSERT' (422A) RIGID PVC 3 EXTRUDED VINYL HANDLE STILE • (475B) RIGID PVC 4 EXTRUDED VINYL LOCK STILE • (494B) RIGID PVC 5 EXTRUDED VINYL KEEPER STILE. (493B) RIGID PVC 6 EXTRUDED VINYL GLAZING BEAD • (446B) RIGID PVC 7 EXTRUDED VINYL TOP RAIL • (4248) RIGID PVC 8 EXTRUDED VINYL BOTTOM RAIL ` (424B) RIGID PVC 9 VENT STOP (ASHLAND)(# 10821) RIGID PVC 10 ANTI-UFT TRACK' (206) RIGID PVC 11 SLIDER TRACK* (206) RIGID PVC 12 REINFORCEMENT (484) ALUM. 17 ROLLERS 18 LOCK ASSEMBLY (TRUTH) STEEL 20 GLASS SETTING BLOCK 22 8 X 1-1/4" FH SMS STEEL 23 8 X 1 /7' PH SMS STEEL THE APPROVED WHITE RIGID PVC EXTERIOR EXTRUSIONS FOR WINDOWS ARE TO BE PRODUCED BY EXTRUDERS LICENSEES IN "AAMA CERTIFICATION PROGRAMS FOR RIGID PVC EXTRUSIONS". 7/8" O.A. GLASS THK. 3/16" ANNEALED AIRSPACE 3/16" ANNEALED FOAM SPACER 1/7' GLASS 8RE L\ GLAZING SILICONE Gl GIAIING BEAD r— 1.47' —1 0 0 r TOP RAIL T FRAME 0 8 BOTTOM RAIL w mod); @:O mM pm Em o m o Ld0oa 0.07' m maifa112 s4 6Ecz HANDLE STILE z 5 KEEPER STILE o z CDczmwo LL o o Z FLANGEINSERT o a m a 4 LOCK STYLE ue N.T.S. 3 c. BY: JK m K. BY: LFS 3 AWWI: ND.: R v FL-16842.16 0N cET 4 OF 4