Loading...
200 W 5 St - BR18-004350 - REROOFSr.,l Ok/ • U BUILDING PERMIT APPLICATION Application No: I - qJ so Documented Construction Value: $ 12665 Job Address: 200 W 15th St, Sanford, FL 32771 Historic District: Yes No[] Parcel ID: 36-19-30-502-0000-0080 Residential Commercial Type of Work: New Addition Alteration Repair Demo Change of Use Move Description of Work: re -roof 27 squares of shingles and 12 squares of modified bitumen Plan Review Contact Person: Phone: 407-453-2222 Jared Conte Fax; 321-296-7571 Title: Roofing Contractor Email: Jared@roofingpioneers.com Property Owner Information Name STORY, PATRICK S STORY, KENDALL L Street: 200 W 15th St, Sanford, FL 32771 City, State Zip: Name Roofing Pioneers, LLC Phone: 407-205-6845 Resident of property?: Contractor Information Street: 1809 E Broadway St, Suite 353, Oviedo, FL 32765 City, State Zip: Name: Street: City, St, Zip: Bonding Company: Address: Phone: 407-453-2222 Fax: 321-296-7571 State License No.: CCC1329030 Architect/Engineer Information Phone: Fax: E-mail: Mortgage Lender: Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED'AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. FBC 105.3 Shall be inscribed with the date ofapplication and the code in effect as of that date: 6" Edition (2017) Florida Building Code ONTICS: In addition to the requirements of this permit, there maybe additional restrictions applicable to this property that maybe found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time ofsubmittal. The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value, credit will be applied to your permit fees when the permit is issued. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Signature of Owner/Agent PrintOwner/Agent's Name Date Signature of Notary -State ofFlorida Date Owner/Agent is Personally Known to Me or Produced ID Type of ID 10/19/18 Signs ure Contractor/Agent Date Jared Conte Print Contractor/Agent's Name "Ay Pl,s c+ WAL.TER 0. RUF MY COMMISSION # FF 97M 10/ 19/ 18 EXPIRES: March 43, 20200ylFoF:ff ftd04TkuBudgdMarySent Signature of Notary -State of Florida Date Contractor/Agent is -X— Personally Known to Me or Produced ID Type of ID BELOW IS FOR OFFICE USE ONLY Permits Required: Building Electrical Mechanical Plumbing Gas Roof Construction Type: Occupancy Use: Total Sq Ft of Bldg: Min. Occupancy Load: New Construction: Electric - # of Amps Fire Sprinkler Permit: Yes No # of Heads APPROVALS: ZONING: ENGINEERING:' COMMENTS: UTILITIES: FIRE: Flood Zone: of Stories: Plumbing - # of Fixtures Fire Alarm Permit: Yes No WASTE WATER: BUILDING: fru.NA6OOUN7Y. FLORIDA Parcel Information Proper Record Card Parcel: 36-19-30-502-0000-0080 Property Address: 200 W 15TH ST SANFORD, FL 32771 Parcel 36-19-30-502-0000-0080 OWner(s) ST0RY,-PATRICK3_-__-_- STORY KENDALLL Property Address 200 W 15TH ST SANFORD, FL 32771 Mailing 200 W 15TH S S SANFORD, FL 32771- Subdivision Name KEELEYS ADD TO SANFORD Tax District S1-SANFORD DOR Use Code 01-SINGLE FAMILY Exemptions 00-HOMESTEAD(2017) C. Ln d Value Summary i 2018 Working 2017 Certified Values Values Valuation Method Cost/Market Cost/Market Number of Buildings 1 1 Depreciated Bldg Value 158,811 j $142,827 Depreciated EXFT Value 1 $14,060 10,630 Land Value (Market) 1 56,070 1 $51,398 Land Value Ag d Just/Market Value F $228,941 1 $204,855 Portability Adj v Save Our Homes Adj 1 19,784 so Amendment 1 Adj 0 P&G Adj mm, _ t o Assessed Value i $209,157 i1 $204,855 8 w Tax Amount without SOH: $3,112.89 2017 Tax Bill Amount $3,112.89 Tax Estimator 1 '' •: Save Our Homes Savings: $0.00 TRIM Notice Help t 4' ' Does NOT INCLUDE Non Ad Valorem Assessments I Legal Description LOT 8 & E 1/2 OF ST ADJ ON W G C KEELEYS ADD TO SANFORD PB2 PG 86 Taxes Taxing Authority Assessment Value Exempt Values Taxable Value County General Fund 209,157 50,000 € 159,157 Schools 209157 25,000 1 184,157 City Sanford 209,157 j 50,000 s 159,157 SJ1NM(Saint Johns Water Management) 20Q157 50,000 ; 159,157 County Bonds 209,157 I 50,000 1 159,157 I Sales Description Date Book Page Amount Qualified VaGlmp WARRANTY DEED 1 4/1/2016 08670 1537 239,900 i Yes Improved SPECIAL WARRANTY DEED 11l1/2015 108621 Q 92 500 i No Improved CORRECTIVE DEED 1 11l1/2015 i 08623 144776 100 No Improved CERTIFICATE OF TITLE 2l1/2015 08411 1-337 100No Improved WARRANTY DEED 6 7/1/1995 102948 0348 83 000 Yes i Improved WARRANTY DEED 1 9/1/1992 02489 Q,]$ 83,000 Yes Improved WARRANTY DEED 4/1/1987 01835 5Q 70 000 I Yes Improved WARRANTY DEED F 1/1/1976 01090 QyQQ 210ss Yes Improved WARRANTY DEED j 1/1/1973 lam 1=$20,000 Yes Improved Find Comparable Sales f Land Method Frontage Depth Units Units Price Land Value Roofing Pioneers, LLC Jared Conte (407) 453-2222 jared@roofingpioneers.com Florida Certified Roofing License #CCC1329030 Visit Us at www.roofiingpioneers.com Tyler Hansen Quality First Builders 200 W 15th St, Sanford, FL 32771 lyler agfbuilders.com 407-205-6845 Re -roof Unit Qty Unit Price Total Architectural Shingle with limited lifetime warranty SQ 27.00 $ 280.00 $ 7,560.00 Modified bitumen SQ 12.00 $ 330.00 Repairing the rafter per engineering, fixing the fascia/ soffit, LS 1.00 $ 1,145.30 and repairing the sheathing that is visibly damaged by the tree impact. 3,960.00 1,145.30 Total $ 12,665.30 Notes 1 Re -roof includes complete tearing off shingles and then replaced with new material. 2 New material includes felt paper, all vents, goose necks, lead boots, drip edge, and peel&stick flashing for the valley. 3 Cost of permit and hauling off trash is included. 4 All work includes a 5 year warranty for workmanship. 5 Additional cost to replace e9ch sheet of plywood is $65 and $6.50 per linear foot of 1" plank board decking. 6 Deteriorated fascia and truss will be replaced at an additional cost of $6.50 per linear foot. 7 If needed, additional cost to remove extra layer of shingles is $25 per square. 8 The new roof installation will bring the decking/nail pattern and the roof up to the current Florida Building Code and the current Wind Mitigation form OIR-131-1802. Page 1 of 1 VI GI It IVIcilu , VlCl 11 Vl I IIC lsll gull Uint at %oulII uUUCI owIIII WIC VUulll rl- lnst #2018 20l99 Book:9234 Page:1038; (1 PAGES) RCD: 10/18120, 10:37:35 AM REC FEE $10.00 THIS INSTRUMENT PREPARED BY: Name: Jared Conte Address: 1808 E Broadway St. Suite 353 Oviedo. FL 32765 _ NOTICE OF COMMENCEMENT State of Florida County of Seminole Perrot Number, Parcel Number: 36-19-30-502-0000-0080 r The undersigned hereby gives notice that improvement 0 be made to certain real property, and in accordance wlthChapter713, Florida Statutes, the following information is provided in this Notice of Commencement DESCRIPTION OF PROPERTY. (Legal description ofthe property and street address ifavailable) LOT 8 & E 1/2 OF ST ADJ ON W G C KEEI EYS ADD TO SANFORD PB 2 PG 86 200 W 15th St, Sanford, FL 32771 GENERAL DESCRIPTION OF IMPROVEMENT: re -roof OWNER INFORMATION: Name: Patrick S & Kendall L Sto Address: 200 W 15th St, Sanford, FL 32771 Fee Simple Title Holder (if other than owner) Name: Address: CONTRACTOR: Name: Roofing Pioneers, LLC Address: 1809 E Broadway St. Suite 353, Oviedo, FL 32765 Persons within the State of Florida Designated by Owner upon whom notice or other documents may be served as provided by Section 713.13(1)1b), Florida Statutes. Name: In addition to himself, Owner Designates To receive a copy of the Liences Notice as Provided in Section 713.13(1)(b), Florida Statutes. Expiration Dabs of Notice of Commencement (The expiration date is 1 year from date of recording unless a dtlerent date is specified) WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1. SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED .ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. Under penalties of perjury, I declare that I have read the foregoing and that the facts stated in it are true to the best of my knowledge and belief. Ignahue Owner'sPrinted Nwq Florida Statute 713.13(1)(g): ' The owner must sign the notice of commencement and no one else may bepermitted tosigninhis or her stead.' State of Lf js -N &A- County of v, n The foregoing instrument was acknowledged before me this day of CD h e - a by Name of person malting OR who has BEIMMASHAItNli f ` Y public • SUte of Florida ommhston 0 GG 2119I8 aM1ih1Y_tomm. Expires May 17, 2021 Bonded ftv* tutlonal NoMry Assn. Who is personally known to ma uJ d"! identification mdcD —ll I7 V O LIMITED POWER OF ATTORNEY Altamonte Springs, Casselberry, Lake Mary, Longwood, Sanford, Seminole County, Winter Springs Date: September 27, 2018 I hereby name and appoint: Jose Cordonero an agent of: Roofing Pioneers, LLC Name of Company) to be my lawful attorney -in -fact to act for me to apply for, receipt for, sign for and do all things necessary to this appointment for (check only one option): The specific permit and application for work located at: 200 W 15th St, Sanford, FL 32771 Street Address) Expiration Date for This Limited Power of Attorney: September 27, 2019 License Holder Name: Jared Conte State License Number: CCC1329030 Signature of License Holder:'VA O.L'- STATE OF FLORIDA COUNTY OF SEMINOLE The foregoing instrument was acknowledged before me this 27 day of Sept , 20018 , by Jared Conte who is X personally known to me or who has produced identification and who did (did not) take an oath. Notary Seal) zotl Y r ek, WALTER D. RUF t MY COMMISSION # FF 970&% EXPIRES: Mamh A 2020 FpF.ftOQ' eadea Ttxu Bud* homy sOMM Rev. 08.12) Signature Print or type name Notary Public - State of _ Commission No. My Commission Expires: as G ;vi 71 Business & Professional Regulation OBPRf1078E{OBI ,DBPR DI7IBIDNS'CBR'7:ACTi08PR FI lida Product Approval I USER: Public User p Product Approval Menu > Product or Application Search > Application Llst > Application Detail lowM, FL # FL16305-R6 Application Type Revision Code Version 2017 Application Status Approved Comments Archived Product Manufacturer Atlas Roofing Corporation Address/Phone/Email 2000 RiverEdge Parkway Suite 800 Atlanta, GA 30328 770)946-4571 mcollins@atlasroofing.com Authorized Signature Meldrin Collins mcollins@atlasroofing.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Roofl ng Subcategory Asphalt Shingles Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer 0 Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed Zachary R. Priest the Evaluation Report Florida License PE-74021 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 12/31/2020 Validated By Locke Bowden 2 Validation Checklist - Hardcopy Received Certificate of Independence FL16305 R6 COI ATL13002 6 2017 FBC Eval Report Shingles final pdf Referenced Standard and Year (of Standard) Standard ASTM D 3161 ASTM D 3462 ASTM D 7158 TAS 100 TAS 107 Equivalence of Product Standards Certified By Sections from the Code Year 2016 2010 2011 1995 1995 Product Approval Method Method 1 Option D Date Submitted 09/30/2017 Date Validated 10/03/2017 Date Pending FBC Approval 10/04/2017 Date Approved 12/12/2017 Summary of Products FL # Model, Number or Name Description 16305.1 Atlas Shingles Fiberglass reinforced laminated asphalt shingles Limits of Use Installation Instructions Approved for use in HVHZ: Yes FI 16309 R6 IT AT] 13002.6 2017 FBC Fval Report Shingles final.DdfApprovedforuseoutsideHVHZ: Yes Impact Resistant: N/A Verified By: Zachary R. Priest 74021 Design Pressure: N/A Created by Independent Third Party: Yes Other: See evaluation report for limits of use Evaluation Reports FL16305 R6 AE ATL13002.6 2017 FBC Eval Report Shingles final.Ddf Created by Independent Third Party: Yes Beck Next CgpgU Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statemerrt :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone orby traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275 1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address ifthey have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available tothe public. To determine if you are a licensee under Chapter 455, F.S., please click fig. Product Approval Accepts: W LRVE 99 M Credit Card Safe Certificate of Authorization No. 29824 17520 Edinburgh Dr Tampa, FL 33647 T"ECHNIICAL, SERVICES, LLC (813) 480-3421 EVALUATION REPORT FLORIDA BUILDING CODE 6'" EDITION (2017) Manufacturer: ATLAS ROOFING CORPORATION 2000 Riveredge Parkway, Suite 800 Atlanta, GA 30328 770) 612-6267 Manufacturing Plants: Hampton, GA Meridian, MS Dangerfield, TX Ardmore, OK Franklin, OH Quality Assurance: UL LLC (QUA9625) SCOPE Category: Roofing Subcategory: Asphalt Shingles Code Sections: 1504.1.1, 1507.2.5, 1507.2 7.1, 1523.6.5.1 Properties: Physical properties, Wind Resistance, Wind Driven Rain PRODUCT DESCRIPTION Issued September 30, 2017 Legend (Ardmore) ASTM D 3161, Class F fiberglass reinforced, 3-tab asphalt shingle with a dashed, thermally -activated, self-sealing sealant stripe that complies with ASTM D 3462. GlassMaster4i)30 ASTM D 3161, Class F fiberglass reinforced, 3-tab asphalt shingle with a dashed, Ardmore & Hampton) thermally -activated, self-sealing sealant stripe that complies with ASTM D 3462. Tough -Master® 20 ASTM D 3161, Class F fiberglass reinforced, 3-tab asphalt shingle with a dashed, Ardmore & Hampton) thermally -activated, self-sealing sealant stripe that complies with ASTM D 3462. Pro -Cut® Hip & Ridge ASTM D 3161, Class F fiberglass reinforced, hip and ridge asphalt shingle with a Ardmore & Hampton) dashed, thermally -activated, self-sealing sealant stripe that complies with ASTM D 3462. Pro -Cut® Starter Strip ASTM D 3161, Class F fiberglass reinforced, starter asphalt shingle with a dashed, Hampton) thermally -activated, self-sealing sealant stripe that complies with ASTM D 3462. ProLAMTM Architectural ASTM D 3161, Class F & ASTM D 7158, Class H fiberglass reinforced, laminated Hampton, Franklin & architectural asphalt shingle with a dashed, thermally -activated, self-sealing sealant Meridian) stripe that complies with ASTM D 3462 Pinnacle® Pristine, ASTM D 3161, Class F & ASTM D 7158, Class H fiberglass reinforced, laminated Pinnacle® Pristine architectural asphalt shingle with two, dashed, thermally -activated, self-sealing sealant Lifetime w/Scotchgard stripes that complies with ASTM D 3462. Dangerfield, Hampton, Franklin & Meridian) StormMaster0Shake ASTM D 3161, Class F & ASTM D 7158, Class H fiberglass reinforced, laminated Dangerfield) architectural modified asphalt shingle with two, dashed, thermally -activated, self-sealing sealant stripe that complies with ASTM D 3462. ATL13002.6 FL 16305-R6 Page 1 of 11 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. ATLAS ROOFING CORPORATIONCREEKAsphaltShingles TECHNICAL SERVICES, LLC StormMaster® Slate ASTM D 3161, Class F & ASTM D 7168, Class H fiberglass reinforced, laminated Ardmore) architectural modified asphalt shingle with two, dashed, thermally -activated, self-sealing sealant stripe that complies with ASTM D 3462. REFERENCES Entity Report No. Standard Year PRI Construction Materials Technologies (TST5878) ATL-079-02-01 ASTM D 3161 2016 TAS 107 1995 PRI Construction Materials Technologies (TST5878) ATL-083-02-01 TAS 100 1995 PRI Construction Materials Technologies (TST5878) ATL-086-02-01 Rev 1 ASTM D 3462 2010A PRI Construction Materials Technologies (TST5878) ATL-104-02-01 ASTM D 3462 2010A PRI Construction Materials Technologies (TST5878) ATL-106-02-01 ASTM D 3161 2016 TAS 107 1995 PRI Construction Materials Technologies (TST5878) ATLA06-02-01 Rev 1 ASTM D 3161 2016 TAS 107 1995 PRI Construction'Materials Technologies (TST5878) ATL-107-02-01 TAS 100 1995 PRI Construction Materials Technologies (TST5878) ATL-107-02-01.1 TAS 100 1995 PRI Construction Materials Technologies (TST5878) ATL-109-02-01 ASTM D 7158 2011 PRI Construction Materials Technologies (TST5878) ATLA 16-02-01 ASTM D 3462 2010A PRI Construction Materials Technologies (TST5878) ATLA 18-02-01 ASTM D 3462 2010A PRI Construction Materials Technologies (TST5878) ATLA 19-02-01 TAS 100 1995 PRI Construction Materials Technologies (TST5878) ATL-123-02-01 ASTM D 7158 2011 PRI Construction Materials Technologies (TST5878) ATL-125-02-01 TAS 100 1995 PRI Construction Materials Technologies (TST5878) ATL-127-02-01 Rev 1 ASTM D 7158 2011 PRI Construction Materials Technologies (TST5878) ATLA 32-02-01 ASTM D 3161 2016 TAS 107 1995 PRI Construction Materials Technologies (TST5878) ATLA 33-02-01 ASTM D 3161 2016 TAS 107 1995 PRI Construction Materials Technologies (TST5878) ATL-135-02-01 ASTM D 3462 2010A PRI Construction Materials Technologies (TST5878) ATLA 36-02-01 ASTM D 3462 2010A PRI Construction Materials Technologies (TST5878) ATL-137-02-01 Rev 1 ASTM D 7158 2011 PRI Construction Materials Technologies (TST5878) ATLA 38-02-01 Rev 1 ASTM D 7158 2011 PRI Construction Materials Technologies (TST5878) ATL-143-02-01 ASTM D 3161 2016 TAS 107 1995 PRI Construction Materials Technologies (TST5878) ATL-144-02-01 ASTM D 3161 2016 TAS 107 1995 PRI Construction Materials Technologies (TST5878) ATLA 51-02-01 ASTM D 3462 2010A PRI Construction Materials Technologies (TST5878) ATL-162-02-01 TAS 100 1995 PRI Construction Materials Technologies (TST5878) ATL-167-02-01 ASTM D 3161 2016 PRI Construction Materials Technologies (TST5878) ATL-168-02-01 ASTM D 3161 2016 TAS 107 1995 PRI Construction Materials Technologies (TST5878) ATL-169-02-01 ASTM D 3462 2010A PRI Construction Materials Technologies (TST5878) ATLA 70-02-01 ASTM D 3462 2010A PRI Construction Materials Technologies (TST5878) ATL-171-02-01 ASTM D 3462 2010A PRI Construction Materials Technologies (TST5878) ATL-172-02-01 ASTM D 3462 2010A PRI Construction Materials Technologies (TST5878) ATL-174-02-01 ASTM D 3462 2010A PRI Construction Materials Technologies (TST5878) ATL-179-02-01 TAS 100 1995 PRI Construction Materials Technologies (TST5878) ATL-184-02-01 ASTM D 3161 2016 TAS 107 1995 PRI Construction Materials Technologies (TST5878) ATLA 85-02-01 ASTM D 7158 2011 PRI Construction Materials Technologies (TST5878) ATL-186-02-01 TAS 100 1995 PRI Construction Materials Technologies (TST5878) ATL-187-02-01 ASTM D 3462 2010A PRI Construction Materials Technologies (TST5878) ATL-220-02-01 ASTM D 3462 2010A PRI Construction Materials Technologies (TST5878) ATL-220-02-02 TAS 100 1995 PRI Construction Materials Technologies (TST5878) ATL-220-02-03 ASTM D 3161 2016 TAS 107 1995 PRI Construction Materials Technologies (TST5878) ATL-220-02-04 ASTM D 7158 2011 PRI Construction Materials Technologies (TST5878) ATL-221-02-01 ASTM D 3462 2010A PRI Construction Materials Technologies (TST5878) ATL-221-02-02 TAS 100 1995 PRI Construction Materials Technologies (TST5878) ATL-221-02-03 ASTM D 3161 2016 TAS 107 1995 PRI Construction Materials Technologies (TST5878) ATL-221-02-04 ASTM D 7158 2011 PRI'Construction Materials Technologies (TST5878) ATL-222-02-01 ASTM D 3462 2010A PRI Construction Materials Technologies (TST5878) ATL-222-02-02 TAS 100 1995 PRI Construction Materials Technologies (TST5878) ATL-222-02-03 ASTM D 3161 2016 ATL13002.6 FL 16305-R6 Page 2 of 11 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC ATLAS ROOFING CORPORATION Asphalt Shingles Entity Report No. Standard Year TAS 107 1995 PRI Construction Materials Technologies (TST5878) ATL-222-02-04 ASTM D 7158 2011 PRI Construction Materials Technologies (TST5878) ATL-223-02-01 ASTM D 3462 2010A PRI Construction Materials Technologies (TST5878) ATL-223-02-02 TAS 100 1995 PRI Construction Materials Technologies (TST5878) ATL-223-02-03 ASTM D 3161 2016 TAS 107 1995 PRI Construction Materials Technologies (TST5878) ATL-223-02-04 ASTM D 7158 2011 PRI Construction Materials Technologies (TST5878) ATL-224-02-01 ASTM D 3462 2010A PRI Construction Materials Technologies (TST5878) ATL-225-02-01 ASTM D 3462 2010A PRI Construction Materials Technologies (TST5878) ATL-225-02-02 TAS 100 1995 PRI Construction Materials Technologies (TST5878) ATL-225-02-03 ASTM D 3161 2016 TAS 107 1995 PRI Construction Materials Technologies (TST5878) ATL-225-02-04 ASTM D 7158 2011 ATL13002.6 FL 16305-116 Page 3 of 11 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEKTechnicalServices, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC Pinnacle® Pristine & Basic Wind Speed (V,dt): StormMaster® Shake Basic Wind Speed (Vasd) Deck (HVHZ): Deck (Non-HVHZ) Underlayment: Min. slope: Installation (HVHZ) Installation (Non-HVHZ): ATLAS ROOFING CORPORATION Asphalt Shingles Max. 194 mph Max. 150 mph In accordance with FBC requirements; Solidly sheathed min. 19/32 in. plywood or wood plank for new construction; Min. 15/32 in. plywood existing construction. In accordance with FBC requirements; Solidly sheathed mina 15/32 in. plywood or wood plank for new construction; Min. 7/16 in. OSB existing construction. In accordance with FBC requirements. 2:12 and in accordance with FBC requirements. Contact the Atlas Roofing Corporation when installing at slope greater than 21:12. Installed with 6 in. exposure in accordance with RAS 115 and manufacturer's published installation instructions. Shingles shall be attached using "6 Nail Pattern" detailed below. Installed with 6 in. exposure in accordance with FBC requirements and manufacturer's published installation instructions. Shingles shall be attached using either "4 Nail Pattern" or "6 Nail Pattem" detailed below. 42- DOUBLE X" SEALANT LINE PATTERN TOP: 1 LENGTH ON: 3OFF BOTTOM: 1" LENGTH ON: 1" OFF 13 V3' I!- TY LI O' NAIUNG AREA 1 71- 6j" 1 6141- Figure 7. Pinnacle® Pristine and StormMasterO Shake 4 Nail Pattern (Non-HVHZ only) 42- BOTTOM: 1" LENGTH ON: I" OFF o TIP or T_; 4' NABJNC AREA Figure 8. Pinnacle® Pristine and StormMaster® Shake 6 Nail Pattern ATL13002. 6 FL 16305-R6 Page 7 of 11 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC Pro -Cut® Starter Strip Basic Wind Speed (Vat): Basic Wind Speed (V,,d): Deck (HVHZ): Deck (Non-HVHZ): Underlayment: Min. slope: Installation (HVHZ): Installation (Non-HVHZ): ATLAS ROOFING CORPORATION Asphalt Shingles Max. 194 mph Max. 150 mph In accordance with FBC requirements; Solidly sheathed min. 19/32 in. plywood or wood plank for new construction; Min. 15/32 in. plywood existing construction. In accordance with FBC requirements; Solidly sheathed min. 15/32 in. plywood or wood plank for new construction; Min. 7/16 in. OSB existing construction. In accordance with FBC requirements. 2:12 and in accordance with FBC requirements. Contact the Atlas Roofing Corporation when installing at slope greater than 21:12. Installed in accordance with RAS 115 and manufacturer's published installation instructions. Shingles shall be attached as shown below. Installed in accordance with FBC requirements and manufacturer's published installation instructions. Shingles shall be attached as shown below. 36- t u i.,n Figure 11. Pro -Cut® Starter Strip ATL13002.6 FL 16305-116 Page 9 of 11 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC ATLAS ROOFING CORPORATION Asphalt Shingles Pro -Cut® Hip & Ridge Basic Wind Speed (Vut): Max. 194 mph Basic Wind Speed (V,,d): Max. 150 mph Deck (HVHZ): In accordance with FBC requirements; Solidly sheathed min. 19/32 in. plywood or wood plank for new construction; Min. 15/32 in. plywood existing construction. Deck (Non-HVHZ): In accordance with FBC requirements; Solidly sheathed min. 15/32 in. plywood or wood plank for new construction; Min. 7/16 in. OSB existing construction. Undedayment: In accordance with FBC requirements. Min. slope: 2:12 and in accordance with FBC requirements. Installation (HVHZ and Installed with 5-5/8 inch exposure in accordance with RAS non-HVHZ): 115 (HVHZ only) and manufacturer's published installation instructions. The direction of the exposed end shall be away from the prevailing wind. 12" i I 12 ga. 1-1/2" ring r shank nail 12" 6" i I , I Figure 12. Pro -Cut® Hip & Ridge ATL13002.6 FL 16305-R6 Page 10 of 11 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC ATLAS ROOFING CORPORATION Asphalt Shingles LIMITATIONS 1) Fire Classification is not within the scope of this evaluation. 2) The roof deck and the roof deck attachment shall be designed by others to meet the minimum design loads established for components and cladding and in accordance with FBC requirements. 3) The mean roof height shall be restricted to a maximum 33 ft in the HVHZ. 4) Classification to ASTM D 7158 applies to exposure B & C with a building mean roof height of 33-ft or less. 5) Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck shall be checked for protrusion and corrected prior to underlayment application. 6) Shingles shall be installed starting at the eave in horizontal layers such that the laps shed water from the deck. 7) Installation of the evaluated products shall comply with this report, the FBC, and the manufacturer's published application instructions. Where discrepancies exist between these sources, the more restrictive and code compliant detail shall prevail. 8) All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61 G20-3. COMPLIANCE STATEMENT The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building Code, 6t' Edition (2017) as evidenced in the referenced documents submitted by the named manufacturer. 0111YrIR p'r"4 1,P.•'C E NSF • ''• No 74021 STATE OF :4 ss/0NA%-14.`,` CERTIFICATION OF INDEPENDENCE 2017.09.3 0 12:3 7:24 04'00' Zachary R. Priest, P.E. Florida Registration No. 74021 Organization No. ANE9641 CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. END OF REPORT ATL13002.6 FL 16305-R6 Page 11 of 11 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CITY OF SkXFORD FIRE DEPARTMENT Building & Fire Prevention Division RESIDENTIAL RE -ROOF POLICY & PROCEDURES PERMITTING REQUIREMENTS — NO PLAN REVIEW REQUIRED THIS DOCUMENT (SIGNED) ALONG WITH AN ACCURATE AND COMPLETED RESIDENTIAL RE -ROOF SCOPE OF WORK ARE REQUIRED TO BE SUBMITTED AS PART OF YOUR PERMIT APPLICATION. THE SCOPE OF WORK MUST INCLUDE ALL APPLICABLE FLORIDA PRODUCT APPROVAL NUMBERS FOR ALL ROOF COMPONENTS THAT WILL BE INSTALLED ON THE PROJECT. A PERMIT WILL NOT BE ISSUED WITHOUT THESE DOCUMENTS. COPIES WILL BE MADE TO POST ON THE JOB SITE. PROJECTS LOCATED IN THE SANFORD HISTORIC DISTRICT WILL REQUIRE PLAN REVIEW AND APPROVAL BY THE SANFORD HISTORIC PRESERVATION BOARD INSPECTION POLICY & PROCEDURES A FINAL ROOF INSPECTION IS THE ONLY INSPECTION REQUIRED FOR RESIDENTIAL (SINGLE FAMILY, TOWNHOUSE, MOBILE HOME, APARTMENT AND/OR CONDOMINIUM) RE -ROOF PERMITS. THE FOLLOWING IS REQUIRED TO BE PROVIDE ON THE JOB SITE: PERMIT CARD, POSTED IN A CONSPICUOUS AND WEATHERPROOF LOCATION COMPLETED RESIDENTIAL RE -ROOF SCOPE OF WORK COMPLETED AND NOTARIZED INSPECTION AFFIDAVIT ALL FLORIDA PRODUCT APPROVAL AND CORRESPONDING INSTALLATION INSTRUCTIONS PRODUCT APPROVAL SHALL MATCH WHAT IS ON THE SCOPE OF WORK) DIGITAL PHOTOGRAPHS (MUST INCLUDE THE PERMIT NUMBER OR ADDRESS IN EACH PICTURE) o EACH PLANE OF THE ROOF, SHOWING THE UNDERLAYMENT INSTALLED o ROOF DECK NAILING PATTERN & SPACING (INCLUDING A MEASURING DEVICE OR RULER) o ROOF DECK NAILS USED (INCLUDING A MEASURING DEVICE OR RULER SHOWING SIZE OF NAILS) o UNDERLAYMENT PATTERN & SPACING (INCLUDING A MEASURING DEVICE OR RULER) o DRIP EDGE & VALLEY ATTACHMENT (INCLUDING A MEASURING DEVICE OR RULER) o SHINGLES INSTALLED, NAIL PATTERN AND LOCATION OF NAILS SKYLIGHTS (IF APPLICABLE) o DIGITAL PHOTOGRAPHS SHOWING ALL INSTALLATION COMPONENTS, PER FL PRODUCT APPROVAL o DIGITAL PHOTOGRAPHS SHOWING ALL REQUIRED FLASHING, PER FL PRODUCT APPROVAL FAILURE TO FOLLOW THESE SPECIFIC GUIDELINES WILL RESULT IN AN AFFIDAVIT PROVIDED BY A FLORIDA DESIGN PROFESSIONAL (ARCHITECT OR ENGINEER), CERTIFYING FBC CODE COMPLIANCE BY PERSONAL INSPECTION. CONTRACTOR (OR OWNER/BUILDER) SIGNATURE: 14 DATE: PERMIT # F DT Cityof Sanford Building Divisiong fl Residential Re -Roof Scope of Work JOB ADDRESS: 2 Uo o wjlltyi' t L ;3 )'7 -7 1 STRUCTURE TYPE: OSINGLE FAMILY RESIDENCE/TOWNHOUSE O MOBILE HOME O APARTMENT/CONDOMINIUM RE -ROOF TYPE: REPLACEMENT (TEAR OFF EXISTING ROOF AND REPLACE WITH NEW COMPONENTS) O RE-COVER (NEW ROOF INSTALLED OVER EXISTING ROOF DECK TYPE (PLEASE SPECIFY: PLEASE NOTE: ONL Y 100 SQUARE FEET OF THE EXISTING DECK IS PERMITTED TO BE REPLACED ROOF VENTILATION: O OFF -RIDGE O RIDGE O SOFFIT OPOWERED VENT SKYLIGHTS: O YES O NO IF YES, PLEASE PROVIDE FLORIDA PRODUCT APPROVAL #: MAIN ROOF AREA ROOF SLOPE: O LESS THAN 2:12 O 2:12 - 4:12 O 4:12 OR GREATER O TURBINES TYPE OF ROOF MANUFACTURER FLORIDA APPROVAL SHINGLE uu k G ( nC S I 0 S PRODUCT FL# 1 (J 3V J+ I O METAL FL# O MODIFIED BITUMEN FL# O TORCH DOWN FL# OINSULATED FL# O TILE FL# O OTHER: FL# ROOF EXTENSIONS (PORCHES, PATIOS, ETC.) **IF APPLICABLE** ROOF SLOPE: O LESS THAN 2:12 O 2:12 - 4:12 O 4:12 OR GREATER TYPE OF ROOF MANUFACTURER FLORIDA PRODUCT APPROVAL O SHINGLE FL# O METAL FL# O MODIFIED BITUMEN FL# O TORCH DOWN FL# OINSULATED FL# O TILE FL# O OTHER: FL# Building & Fire Prevention Division RESIDENTIAL RE -ROOF AFFIDAVIT RESIDENTIAL RE -ROOF INSPECTION AFFIDAVIT NAILING, SHEATHING, DRY -IN, FLASHING, AND ALL FINAL ROOF COVERINGS PERMIT #: 18-4350 ADDRESS: 200 W 15th St Sanford FL 32771 I Jared Conte , AS A(N) GENERAL, BUILDING, RESIDENTIAL, OR ROOFING CONTRACTOR, ENGINEER, ARCHITECT, OF F.S. CHAPTER 468 BUILDING INSPECTOR, I HEREBY AFFIRM, THAT ALL OF THE FOREGOING INFORMATION IS TRUE AND ACCURATE AND THAT ALL ROOFING COMPONENTS LISTED ON THE SCOPE OF WORK AT THE ABOVE REFERENCED ADDRESS HAVE BEEN INSTALLED IN ACCORDANCE WITH THEIR PRODUCT APPROVALS AND .ALL APPLICABLE CODE REQUIREMENTS — SPECIFICALLY FLORIDA BUILDING CODE, EXISTING BUILDING. IN ADDITION I CERTIFY THE INSTALLATION MEETS ALL REQUIREMENTS FOR SECONDARY WATER BARRIER AND NAILING OF THE ROOF DECK, IN ACCORDANCE WITH THE HURRICANE RETROFIT MANUAL REQUIREMENTS (BASED ON F.S. CHAPTER 553.844). LICENSE #: CCC1329030 COMPANY / CONTRACTOR: Roofing Pioneers, LLC CONTRACTOR SIGNATURE: MUST BE SIGNED BY LICENSE HOLDER A FINAL ROOF INSPECTION IS REQUIRED: DATE: 10/29/ 18 THIS SIGNED AND NOTARIZED AFFIDAVIT MUST BE PROVIDED AT THE JOB SITE AT THE TIME OF THE FINAL ROOF INSPECTION, ALONG WITH DIGITAL PHOTOGRAPHS OF EACH PLANE OF THE ROOF SHOWING IN DETAIL ALL COMPONENTS (DECKING, UNDERLAYMENT, FLASHING, DRIP EDGE ATTACHMENT) WITH THE PERMIT NUMBER OR ADDRESS CLEARLY MARKED ON THE DECK FOR EACH INSPECTION. THE PHOTOGRAPHS MUST INCLUDE A RULER OR MEASURING DEVICE TO CONFIRM ALL NAIL SPACING AND OVERLAPS, INCLUDING DRIP EDGE AND VALLEY FLASHING. PLEASE REFER TO THE RE -ROOF POLICY AND INSPECTION PROCEDURE PAPERWORK FOR FURTHER EXPLANATION OF ALL REQUIREMENTS. FAILURE TO FOLLOW ALL REQUIREMENTS WILL RESULT IN A FAILED INSPECTION, A RE -.INSPECTION FEE AS WELL AS REQUIRING A DESIGN PROFESSIONAL (ARCHITECT OR ENGINEER) TO CERTIFY, BASED ON PERSONAL INSPECTION, THE INSTALLATION OF ALL ROOFING COMPONENTS. STATE OF FLORIDA COUNTY OF SEMINOLE Sworn to and Subscribed before me this 29 Jared Conte identification) Signature of Notary Public State of Florida Print/Type/Stamp Name of Notary Public day of October 20 18 by: Who is XPersonally Known to me or has Produced (type of as identification. ZtsY peat WALTER O. RU MY C0M=t0N # FF 97fiIi 6 r iXP1RE5: kt d t3-2EY20 ft&dTlxu&PtdNfty&uA=