Loading...
521 Red Rose Ln - BR18-004667 - SOLAR PANELSCITY OF SANFORD BUILDING & FIRE PREVENTION D C PERMIT APPLICATION 16.C Application No: Documented Construction Value: $ A C-4' Pob Address: 521 RED ROSE LN SANFORD, FL 32771 Historic District: Yes No FL1 Parcel ID: 21-19-30-510-0000-3120 Residential ® Commercial Type of Work: New Addition ® Alteration Repair Demo Change of Use Move Description of Work: Installation of photo voltaic solar panels Plan Review Contact Person: Aimee McGurr Phone: 321-247-6073 Fax: Title: Permitting Email: flpemnits@momentumsolar.com Property Owner Information Name Venkataramakrishna Nampally Phone: 321-247-6073 Street: 521 RED ROSE LN Resident of property? : Yes City, State Zip: SANFORD, FL 32771 Contractor Information Name Momentum Solar / Cameron Christensen Phone: 321-247-6073 Street: 8248 Parkline Blvd. Ste 100 Fax: City, State Zip: Orlando, FL 32809 State License No.: CVC57036 Architect/Engineer Information Name: Luis Perez Phone: Street: 14552 Driftwood Ct Fax: City, St, Zip: Winter Garden, FL 34787 E-mail: luis@lrpengineering.com Bonding Company: Address: Mortgage Lender: Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Application is hereby made to obtain a permit to do the work and installations as indicated. 1 certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, we0s, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: 51° Edition (2014) Florida Building Code Revised: June 30, 2015 Permit Application NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal. The actual construction value will be figured based on the current ]CC Valuation Table in effect at the time the permit is issued, in accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value, credit will be applied to your permit fees when the permit is issued. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. ti I l /Zo L'6 Signature of Owner/Agent Date Vf N gAT ti A MPAL-L-y Print Owner/Agent's Name Signature of Notary -State of Florida bate Aimee McGurc NOTARY PUBLIC c _ -STATE OF FLORIDA W ? Comm# GG200147 NCE 19Re Expires 10/23/2021 Owner/Agent is Personally Known to Me or Produced ID is Type of ID DL 1 Signature ofContractor/Agent Date C ^'eran C Print con or/Agent' erne Signature of Notary -State of Florida Date IRV Aimee V Ctt Urr a NOTARY PUBLIC gsSTATE OF FLORIDA Commie GG200147 vE 19 e Expires 10/23/2021 Contractor/Agent is r Personally Known to Me or Produced ID Type of ID BELOW IS FOR OFFICE USE ONLY Permits Required: Building Electrical Mechanical Plumbing[] Gas Roof Construction Type: Total Sq Ft of Bldg: Occupancy Use: Flood Zone: Min. Occupancy Load: of Stories: New Construction: Electric - # of Amps Plumbing - # of Fixtures Fire Sprinkler Permit: Yes[] No APPROVALS: ZONING: ENGINEERING: COMMENTS: of Heads UTILITIES: FIRE: Fire Alarm Permit: Yes No WASTE WATER: BUILDING: `SF Revised: June 30, 2015 Permit Application 11/30/2018 SCPA Parcel View: 21-19-30-510-0000-3120 tx/t scwacoourrv,anna Parcel Information rooeRecord Card Parcel: 21-19-30-510-0000-3120 Property Address: 521 RED ROSE LN SANFORD, FL 32771 Value Summary Parcel 21-19-30-510-0000-3120 Owner( s) NAMPALLY, VENKATARA_MAKRISHNA - Tena_ ncy by Entirety NAMPALLY MANASA - Tenancy by Entirety Property Address 521 RED ROSE LN SANFORD. FL 32771 Mailing 521 RED ROSE LN SANFORD. FL 32771-1650 Subdivision Name THORNBROOKE PHASE 4 Tax District S1-SANFORD DOR Use Code 01SINGLE FAMILY Exemptions 00-HOMESTEAD(2019) j I Legal Description LOT 312 THORNBROOKE PHASE 4 PB 81 PGS 70-71 2019 Working 2018 Certified Values Values Valuation Method Cost/Market Cost/Market r a Number of Buildings 1 0 Depreciated Bldg Value 251.140 jIt DepredatedEXFTValuejLend Value (Market) i $40,000 1 $40.000 Land value Ag j JusUMarket Value " 291.140 40.000 Portability Adj Save Our Homes Adj II $0 0 Amendment 1 Adj t $0 t $0 Pay Adj o 0 Assessed Value - 291,140 40,000 Tax Amount without SOH: $750.00 2018 Tax Bill Amount $750.00 Tax Estimator Save Our Homes Savings: $0.00 Does NOT INCLUDE Non Ad Valorem Assessments Taxes-- -- - - - - -- ----- ----- -- - - --- - I Taxing Authority Assessment Value Exempt Values Taxable Value County General Fund $291,140 50,000 241.140 Schools 291.140 ! 25,000 266.140 City Sanford 291.140 50,000 241.140 SJWM( Saint Johns Water Management) 291,140 I 50, 000 241,140 County Bonds 291.140 ; 50,000 241.140 Sales I, Description Date Book Page Amount Oualified Vac/Imp SPECIAL WARRANTY DEED 9/1/2018 09227 0197 304.700 I Yes Improved Find Cwnparabla Saris Land Method Frontage Depth Units Units Price Land Value LOT 1 $40.000.00 $40.000 r Building Information Is Bed/Bath Bed/Bathcountinco ect CI ck tjeLe, q Description Year Built Fixtures Bed Bath Base Area Total SF Living SF Ext Wall Adj Value Repl Value Appendages Actual/Effective1i SINGLE 2018 131 4 3 55 1,456 3.530 2,862 , CB/STUCCO ' $251,140 ' $251.140 , Description Area FAMILY FINISHBASE280. 00 httpJ/pareeldetall. scpafl.org/PareelDetaillnfo.aspx?PID=21193051000003120 1/2 DocuSign Envelope ID: 647130370-59B7-4580.9776-D108E4D4BE36 THIS IS A COPY The Authoritative Copy of this record is held at na2.docusign.nel 0 momentum SOLAR SOLAR ELECTRIC INSTALLATION CONTRACT Venkatarama Nam all Customer Name 521 Red Rose Lane Sanford, FL 32771 Service Address City, State, Zip 7723593550 krish510@gmail.com Phone Email Address Electric utility Company Hanwha Q CELLS Enphase Energy 7.875 kW Q.PEAK DUO BLK-G5 315 J\ 1 IQ7-60-2-US\\ i System Size* Solar Module Make/rype Inverter Makerr / = GARDIN, 6le.,6ount IF SYSTEM SIZE IS BIGGER THAN 11.6 KW DC/10.0 KW AC, PLEA C S T MENT' LIABILITY INSURANCE REQUIRMENT ( \ Payment Schedule and Third -party Financing: Your pa rt ents will decom `due` gAdicated below. The "Total Amount Payable to Momentum Solar" shown below ffects on(the a ount e\charge for the PV System (as defined below) and installation, not including any agelicable sales c you chose to obtain financing from a third -party finance company, your payment schedule and total a"q ed will be set out in your agreement with the third -party finance company and may In de fi nce charges. Yoilshould read that agreement carefully to understand your repayment obligatio We are , t your lender. The terms of any financing you obtain from a third party, including the amount' i timi of yourVAyments and any finance charges imposed, are solely determined by your third -party hQince co pany. W6, bre not affiliated with any third -party finance company. TOTAL AMOUNT PAYA L-E O M0\ 0E,9TUM SOLAR: 61,000.00 (PLUS ANY APPLICABLE SALES TAX) DIVIDEND F Refer jo1your agreementadir t6_Dfvidend Finance for a description of your payment obligations, Including yourpaymept\schedulela6d total of payments (including any finance charges). TOTAL AMO NT-PAYABLE TO MOMENTUM SOLAR: $21,000.00 Optional Down Payment: $0.00 Upfront Rebate (if applicable): $0.00 Total Loan Amount: $21,000.00 You acknowledge that, regardless of whether you obtain financing from a third party, we require payment in full upon completion of the installation (and required inspections) and that we are not extending credit to you in connection with this transaction. ACCORDING TO FLORIDA'S CONSTRUCTION LIEN LAW (SECTIONS 713.001-713.37, FLORIDA STATUTES), THOSE WHO WORK ON YOUR PROPERTY OR PROVIDE MATERIALS AND SERVICES AND ARE NOT PAID IN FULL HAVE A RIGHT TO ENFORCE THEIR CLAIM FOR PAYMENT AGAINST YOUR PROPERTY. THIS CLAIM IS KNOWN AS A CONSTRUCTION LIEN. IF YOUR CONTRACTOR OR A SUBCONTRACTOR FAILS TO PAY SUBCONTRACTORS, SUB - SUBCONTRACTORS, OR MATERIAL SUPPLIERS, THOSE PEOPLE WHO ARE OWED MONEY Document.24 FL Page 1 of 9 DocuSign Envelope ID: 6478037D-5987-4580-9776-Dt08E4D4BE36 THIS IS A COPY The Authoritative Copy of this record Is held at na2.docusl9n.nel momentum SOLAR Transfer of Title: The title of the equipment will pass to you upon the delivery of the equipment to your property, or any storage facility you designate. Until the equipment has been delivered and signed for by you or your agent, we retain the title for the equipment. Governing Law: This agreement shall be governed by and construed in all respects in accordance with the laws of the State of Florida as they apply to a contract entered into and performed in that state. Taxes: You acknowledge and understand that you are responsible for any and all taxes that arise under t l greement, including, but not limited to, sales and use taxes. You agree to execute any certificate or other applicable documents relating to sales or use tax exemptions to ensure that you or we, as applicable, may claim exemption from paying or collecting any sales or use tax that arises nder this agreement. You agree to pay all applicable sales or use taxes If such taxes are determined tWhe due at any time before or after the termination or expiration of this agreement. FLORIDA HOMEOWNERS' CONSTRUCTION RECOVERY FUND. PAYME T AZ I D AMOUNT, MAY BE AVAILABLE FROM THE FLORIDA HOMEOWNERS' N RECOVERY FUND IF YOU LOSE MONEY ON A PROJECT PERFO UNDER RA , WHERE THE LOSS RESULTS FROM SPECIFIED VIOLATIONS F RID = W •.,LICENSED CONTRACTOR. FOR INFORMATION ABOUT THE RECOVEF Y AN ING A Lii44 CONTACT THE FLORIDA CONSTRUCTION INDUSTRY LIC R SIB 'D A_ iE FOLLOWING TELEPHONE NUMBER AND ADDRESS: DEPARTM T OF 'USII_ SS F OFESSIONAL REGULATION, 2601 BLAIR STONE RD., TALLAHAS FL 399,(;50) -1395. Acceptance and Authorization: By signing b`- ,ow, you au • - us to perform the installation. Except as set forth in this agreement, you a9re theare no oral o tten representations or inducements, expressed or implied, any waI agreement, and we expressly disclaim their existence. By signing this agreement, you,. ledg t you have read and understand this agreement or have had a competent legal rep re niative plaini erms, and hereby accept this agreement in its entirety. You further acknowlegAge re ruing - mplete c . y of this agreement. You, the buyer, taiy cane li`th%- `transaction at any time prior to midnight of the third business day after the daof this tr'';sa Ilon. See the attached notice of cancellation form for an explanf ti'i right. Cust per Sign turea Pro Custom Solar LLC I d/b/a Momentum Solar: 11/12/18 J V" (Ak November 12, 2018 ampally Date Sung Lee Date Chief Financial Officer Document. 24 FL Page 6 of 9 Grant Maio y Clerk Of The Circuit Court & Comptroller Seminole County FLtnst #20181 i5378 Book:9257 Page:698: (1 PAGES) RCD: 12/3/2018 3:43:18 PM REC FEE $10.00 THIS INSTRUMENT PREPARED BY: Name: Almee McGurr/Momentum Solar Address: Orlarxio, i NOTICE OF COMMENCEMENT v Permit Number. Parcel 10 Number. 21-19-30-510-0000-3120 The undersigned hereby gives notice that Improvement will be made to certain real property, and in accordance with Chapter 713. Florida Statutes, the following Innfforrmmaattion Is provided InnYthis NNooticegoffCCoommmrlenlcegmentt. 1 n 1. O9SI312 ThO F RROk@ PhaS@ 3 PB 81 PGS Irerty and sheet address Havailable) tfi L5021 RED ROSE LN SANFORD, FL 32771 3 2. GENEwJ. DESCRIPTION OF IMP 0VEME gIT. rnif ll'MenQ4 :2kalV ISddl- %bile, 5 3. OWNER INFORMATIO11 ORiLESSEE INFORMATION IF THE WSSEE CONTRACTED FOR THE IMPROVEMENT: n Name and address: Venkstaramakrishns Nampally 521 RED ROSE LN SANFORD, FL 32771 Interest in property: Fee Simple Title Holder (If other than owner listed above) Name: Address: 4. CONTRACTOR: Name: Cameron Christensen / Momentum Solar Phone Number: 321-247-6073 Address: 8248 Parkline Blvd. Ste 100 Orlando, FL 32809 S. SURETY ( If applicable, a copy of the payment bond Is attached): Name: N/A Address,• Amount of Bond: 8. LENDER: Name: WA Phone Number: Address: 7. Persons within the State of Florida Designated by Owner upon whom notice or other documents may be served as provided by Section 713.13( 1Ka)7., Florida statutes. i Name: Phone Number. Address: i 8. In additkm% Owner designates of to receive a copy of the Liences Notice as provided In Section 713.13(1 xb), Florida Statutes. Phone number: 8. Expiration Date of Notice of Commencement (The expiration Is 1 year from date of recording unless a different date Is specified) WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713. PART I, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. v Venkataramakrishna Nampally Slprmew olOamer or Lem*. orOamefe or LSaaeetr (P nt Name and PMAda Mena ) Aurtodaed OftadObxtoM artrtedA4napeQ state of r %olido County of 4A,( &-ok-e- The foregoing Instrument was acknowledged before me this _ ci day of20iTbyVenkataramakrishna Nampally Who Is personally known to me 0 OR Name et peram ffamv aleMlnCd who has produced IdentI icatlon JEE00e of Identification produced: Almee McGurn NQTARY PUBLIC STATE OF FLORIDA Comm GG200147 9 Expires 10/23/2021 L wull 011 SOLAR DATE: 1 U19/2018 8248 Parkline Boulevard, Suite 100 Orlando, FL 32809 Phone: 732.902.6223 I hereby name and appoint ) O 01 rI TG of Momentum Solar to be my lawful attorney -in -fact to act for me, and apply to the Division of Building Safety for a Building/Electrical (PHOTO VOLTAIC SOLAR PANELS) permit ONLY (NOC and Permit Application) for work to be performed at a location described as: Owner of Property: Project Address: and to sign my name and do all things necessary to this appointment. Cameron Christensen Contractor Name) (Type or Print) CVC57036 Contractor's License Number) The foregoing instrument was acknowledged before me this 19 by Cameron Christensen who is personally known to me or who produced did not take an oath. Notary Public (Print Name) Notary P46fiC (Signature) D.L. Con ' nature) day of November Seal of 2018 as identification and who f`Y "e,o JANELL WALLACE MY COMMISSION # GG 096020 EXPIRES: A01 19, 202 1 ofP-° 80nded Thnr Budget Notary Services 118II'JQII1ME D INSPECTION* SEQUENCE BlP# i — l- -i oi ,4 leilrocs• Footer / Foundation / Form Board -Survey Slab lMorio SIab•Pre our Lintel / Tie- Beam / Fill / Down Cell Sheathing , Wa1Is• Sheathing ! Roof01RnnfT)ry in Framer Insulation Rough In Firewall Sciew Pattern Drywall / Sheetrocic Lath Inspection Final Solar Final Roof .I; ' Final Stucco- / •Siding Insulation Final Final Utili ' ; Building - Final Door. I Final -' Window Final Screen Room Final. Pool Screen Enclosure. Mobile Horne Building Final Pre -Demo I Final Demo' Final Single jF= y Resfd'ence Final. Building Other oDIlIIDeSedo® Elect& Under -groundFooter r SIab Steel Bond Electric Rough T. U.G. Pre - Power Final Electric Final Nan mar. IIDIlspeD don IIDesE iietion ~ Plumbing Underground Plumbing Sewer . Plumbing Tub Set Plumbing Final i i ff Mecham" cal Rough ia W..... -..—_<<—:-—..•_ l:'-.,2 rri=as4:i ?,. s - '` ` yL:t^• ''':(,i?'r n in Gas Undergromd o_ R EVYS]ED.- June 2014 I i to RECORD COPY PLAN KEY PV-1 COVER PAGE PV_ 1.1 COVER PAGE CONT. PV-2 PANEL LAYOUT PV-3 LAYOUT DETAIL PV-4 THREE LINE DIAGRAM PV-4.1 ELECTRICAL CONT, PV-4.2 EQUIPMENT LABELS HANWHA Q.PEAK DUO BLK-G5 315 315 WATT MODULE 66.3" X 39.4" X 1.26" SEE DATASHEET) BILL OF MATERIALS MODULES 25 INVERTERS 25 CLAMP ASSEMBLY 74 COUPLING ASSEMBLY 42 BONDING CLIP 9 SKIRTS 13 ENPHASE COMBINER BOX 1 SQUARE-D 60A FUSIBLE AC DISCONNECT 1 40A FUSES 2 35A BACKFEED BREAKER 1 SYSTEM INFORMATION MODULE HANWHA Q.PEAK DUO BLK-G5 315 INVERTER ENPHASE IQ7-60-2-US RACKING ECOFASTEN ROCK -IT SYSTEM SYSTEM SIZE (DC) 7.875 KW LOCATION 28.817166,-81.317885 GENERAL NOTES: THIS PV SYSTEM HAS BEEN DESIGNED TO MEET THE MINIMUM DESIGN STANDARDS FOR BUILDING AND OTHER STRUCTURES OF THE ASCE 7-10, 6TH EDITION 2017 FLORIDA RESIDENTIAL CODE, 6TH EDITION 2017 FLORIDA FIRE PREVENTION CODE, NEC 2014 AND ALL LOCAL CODES & ORDINANCES. ROOF SHALL HAVE NO MORE THAN TWO LAYERS OF COVERING IN ADDITION TO THE SOLAR EQUIPMENT. INSTALLATION OF SOLAR EQUIPMENT SHALL BE FLUSH MOUNTED, PARALLEL TO AND NO MORE THAN 6-INCHES ABOVE THE SURFACE OF THE ROOF. ANY PLUMBING VENTS ARE NOT TO BE CUT OR COVERED FOR SOLAR EQUIPMENT INSTALLATION. ANY RELOCATION OR MODIFICATION OF THE VENT REQUIRES A PLUMBING PERMIT AND INSPECTION. ALL DESIGN, CALCULATIONS ARE PERFORMED BY DANIEL DUNZIK REGISTERED ARCHITECT. FLORIDA STATE STATUTE 471.003(3) PROVIDES THAT LICENSED ARCHITECTS ARE EXEMPTED FROM THE PROVISIONS OF CHAPTER 471 ENGINEERING AND NOT PRECLUDED FROM PERFORMING ENGINEERING SERVICES FOR INTEGRATED SYSTEMS AND SERVICES THAT ARE INCIDENTAL TO BUILDINGS AND STRUCTURES. INVERTER PLACEMENT: SYSTEM UTILIZES "ENPHASE" MICRO -INVERTERS WITH RAPID SHUTDOWN CONTROL LOCATED ON THE BACK SIDE OF EACH MODULE. STRUCTURAL STATEMENT: THE EXISTING STRUCTURE IS ADEQUATE TO SUPPORT THE NEW LOADS IMPOSED BY THE PHOTOVOLTAIC MODULE SYSTEM INCLUDING UPLIFT & SHEAR.EXISTING RAFTER SIZES & DIMENSIONS CONFORM TO 6TH EDITION 2017 FLORIDA RESIDENTIAL CODE MOUNTING BRACKETS AND HARDWARE MEET OR EXCEED FLORIDA CODE REQUIREMENTS FOR THE DESIGN CRITERIA OF THE TOWN. CLIMATIC & GEOGRAPHIC DESIGN CRITERIA TABLE R301.2(1) SPEED (MPH) 140 TOPOGRAPHIC EFFECTS B SPECIAL WIND REGION NO WIND BORNE DEBRIS ZONE 2 SEISMIC DESIGN CATEGORY C CLIMATE ZONE 2A WIND EXPOSURE CATETORY B 1 8' 4667 REVIEWED FOR CODE COMPLIANCE PLANE EXAMINER Z. 6- I & DATE SANFORD BUILDING DIVISION A PERMIT ISSUED SHALL BE CONSTRUED TO BE ALICENSETOPROCEEDWITHTHEWORKANDNOTASAUTHORITYTOVIOLATE, CANCEL, ALTER GR SETASIDEANYOFTHEPROVISIONSOFTHETECHNICALCODES. NOR SHALL ISSUANCE OF A PERMIT PREVENTTHEBUILDINGOFFICIALFROMTHEREAFTERREQUIRINGACORRECTIONOFERRORSINPLANS, CONSTRUCTION OR VIOLATIONS OF THIS CODE FBC, Residential 2017 For SI: 1 mile per hour = 0.447 m/s. a. Linear interpolation is permitted. momentum SOLAR PRO CUSTOM SOLAR LLC D.B.A. MOMENTUM SOLAR 325 HIGH STREET, METUCHEN, NJ 08840 732)902-6224 MOMENTUMSOLAR.COM STRUCTURAL ENGINEERING F No. 80653 STAT r= S ONAIulnun1l11"'1 SOLAR CONTRACTOR CAMERON CHRISTENSEN CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER: CVC57036 MOMENTUM SOLAR 5728 MAJOR BLVD. SUITE 307 ORLANDO FL 32819 CUSTOMER INFORMATION VENKATARAMA NAMPALLY 521 RED ROSE LN SANFORD, FL 32771 772) 359-3550 PV SYSTEM INFORMATION SYSTEM SIZE (DC ): 7.87S KW 25 MODULES: HANWHA Q.PEAK DUO BLK-G5 315 25 INVERTERS: ENPHASE IQ7-60-2-US PROJECT INFORMATION INITIAL DATE: 11/30/2018 DESIGNER: AC REV: DATE: DESIGNER: REV: DATE: DESIGNER: COVER PAGE PV-1 1. ALL WIND DESIGN CRITERIA ARE FOR GABLE AND HIP RESIDENTIAL ROOFS CONSIDERED FROM AN ANGLE OF MIN. 9.5 ° (?) TO MAX. 45' (i) NOT TO EXCEED 30' MEAN ROOF HEIGHT WITH A MIN 16" LAG BOLT (ASTE A276) STAINLESS STEEL INTO THE RAFTER OR BLOCKING BETWEEN RAFTERS W/ MIN. EMBEDMENT OF 3" 2. THIS STRUCTURAL DESIGN REFLECTS STRUCTURAL CONNECTIONS TO THE EXISTING STRUCTURE ONLY. MODULE TO RACK -IT LOADING AND CERTIFICATION PER MECHANICAL LOAD TESTS IAW/ANSI UL2703 CONDUCTED ON BEHALF OF ECOLIBRIUM SOLAR BY TUV RHEELAND REFERENCE FILE L2-ELS150128a (REV 1) 3. ROOF SEALANTS SHALL CONFORM TO ASTMC920 AND ASTM 6511 AND IS THE RESPONSIBILITY OF THE CONTRACTOR TO FILL ALL HOLES WATER TIGHT. 4. "ROCK -IT" ATTACHMENTS ARE MANUFACTURED BY ECOFASTEN SOLAR ARIZONA. AND SHALL BE INSTALLED IN STRICT COMPLIANCE WITH MANUFACTURERS PRINTED INSTRUCTIONS. ROCK -IT TO RAFTER ATTACHMENT SPACING SCHEDULE ULTIMATE DESIGN ROOF ZONE 1 ROOF ZONE 2 & 3 WIND MAX. SPAN / MAX. MAX. SPAN / MAX. SPEED CANTILEVER CANTILEVER MPH) INCHES) INCHES) 125 48" O.C. / 16" MAX. 32" O.C. / 12" MAX. 130 48" O.C. / 16" MAX. 32" O.C. / 12" MAX. 140 48" O.C. / 16" MAX. 24" O.C. / 10" MAX. 150 40" O.C. / 16" MAX. 16" O.C. / 8" MAX. 160 32" O.C. / 12" MAX. 16" O.C. / 8" MAX. 170 32" O.C. / 12" MAX. 14" O.C. / 8" MAX. TABLE REFLECTS ATTACHMENT SPACINGS THAT EXCEED MANUFACTURERS SPECIFICATIONS FOR WIND LOADS AS PER ASCE 07-10. RISK CATEGORY II TOPOGRAPHIC EFFECTS B,C, & D AND ROOF WIND ZONES 1,24 3. ROOF ZONES 2 & 3 ARE WITHIN 48" OF ANY OUTER EDGE, HIP, RIDGE, OR GUTTER LINE FOR STRUCTURES 30'- 0" OR LESS MEAN ROOF HEIGHT. LL Y a Y GUTTER O 2 2) RIDGE T 0_ GUTTER GUTTER w 1Q RIDGE ti GUTTER ROOF WIND ZONES AS PER IRC R301.2(7) ROOF ZONES 2 & 3 ARE 48" FROM OUTER ROOF EDGES, RIDGES, HIPS, RAKES, AND GUTTER EDGES FOR STRUCTURES BELOW 30'-0" MEAN ROOF HT. COUPL CLAMP ATTAC RAF SOLAR MOD COUPI CLAMI ATTA( SOLAR M GU GUT SEE ATTACHMENT SCHEDULE ECOFASTEN SOLAR ROCK -IT 4.0 MOUNTING DETAIL ECOFASTEN SOLAR ROCK -IT 4.0 RAIL -LESS MOUNTING SYSTEM INTEGRATED WITH FLASHING, COUPLINGS AND ADJUSTABLE CLAMP ATTACHMENTS SEE ATTACHMENT SCHEDULE FOR MAXIMUM CANTILEVER MINIMUM 5" SPACING TO GUTTER ECOFASTEN SOLAR ROCK -IT 4.0 MOUNTING DETAIL ECOFASTEN SOLAR ROCK -IT 4.0 RAIL -LESS MOUNTING SYSTEM INTEGRATED WITH FLASHING, COUPLINGS AND ADJUSTABLE CLAMP ATTACHMENTS MAXIMUM SOLAR ARRAY ELEVATION 4.25' MAXIMUM CLAMP ATTACHMENT SPACING . 48" COUPLING CLAMP SOLID BLOCKIP... SETWEEN JOISTS I C1hW Z In w ECOFASTEN' ROCK -IT ATACHMENT SYSTEM ECOFASTEN' 'ROCK-Ir FLASHING ECOFASTEN' SKIRT SOLAR MODULE E)QSTING ROOF MEMBRANE, PLY#000 DECK, AND RAFTER ALL COMPONENTS SHALL BE AS MANUFACTURED BY 'ECOFASTEN SOLAR' AND INSTALLED IN STRICT COMPLIANCE LATH MANUFACTURERS PRINTED SPECIFICATIONS. ATTACHMENT DETAIL FOR SLOPED COMP. SHINGLE ROOF ECOFASTEN' ROC( -IT ATACHMENT SYSTEM ECOFASTEN' SIMPLE GRIP DEC( MOUNT W/ 2 LAG BOLTS TO RAFTER ECOFASTEN' M SOLAR MODULE EXISTING ROOF MEMBRANE, PLYWOOD DECK, AND RAFTER ALL COMPONENTS SHAM BE AS MANUFACTURED BY 'ECOFASTEN SOLAR' AND INSTALLED IN STRICT COMPLIANCE WITH MANUFACTURERS PRINTED SPECIFICATIONS. ATTACHMENT DETAIL FOR LOW -SLOPED ROOF ECCFASTEN' ROC( -IT ATACHMENT SYSTEM ECOFASTEN' EF-44R-SS-NDD ATTACHMENT AND FLASHING W/ SOI AR MOlXX11 E8XHDj15FASTENERSTODEC( ppSTING ROOF MEMBRANE CECOFASTEN' SKIRT // / RAFTER AND ALL COMPONENTS SHALL BE AS MANUFACTURED BY 'ECOFASTEN SOLAR' AND INSTALLED IN STRICT COMPLIANCE WITH MANIIFAC110S PRINTED SPECIFICATIONS ATTACHMENT DETAIL FOR ROOFS AREA WHERE RAFTERS NOT AVAILABLE SOLAk PRO CUSTOM SOLAR LLC D.B.A. MOMENTUM SOLAR 325 HIGH STREET, METUCHEN, NJ 08840 732) 902-6224 MOMENTUMSOLAR.COM STRUCTURAL ENGINEERING 111$11 a Illr//// CENs No. M SCAT rrrnirA,Ituu,,; SOLAR CONTRACTOR CAMERON CHRISTENSEN CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER. CVC57036 MOMENTUM SOLAR 5728 MAJOR BLVD. SUITE 307 ORLANDO FL. 32819 INFORMATION VENKATARAMA NAMPALLY 521 RED ROSE LN SANFORD, FL 32771 772) 359-3550 PV SYSTEM INFORMATION SYSTEM SIZE (DC ): 7.875 KW 25 MODULES: HANWHA Q.PEAK DUO BLK-G5 315 25 INVERTERS: ENPHASE IQ7-60-2-US I PROJECT INFORMATION I IINITIAL IDATE: 11/30/2018 (DESIGNER: AC I IREV: IDATE: IDESIGNER: I IREV: IDATE: IDESIGNER: I COVER PAGE PV-1.1 SCALE: 3/32" = 1'-O" DRIVEWAY n 0 v0 n 0 a In M m Q z M z n M OUDC AC IDISC CB ELECTRICAL EQUIPMENT NOTE: 1. ROOF COVERING MATERIAL IS COMPOSED OF SINGLE LAYER ASPHALT COMPOSITE SHINGLE. 2. REFER TO LAYOUT DETAIL DRAWING PV-3 FOR ALL ROOFTOP DIMENSIONS. ROOF PANEL COUNT TILT AZIMUTH SHADING R1 13 26° 179° 99% R2 12 26° 359` 97% GROUND ACCESS TYP) FIRE SETBACK 36" VENTILATION, 36" ROOF ACCESS) momentum PRO CUSTOM SOLAR LLC D.B.A. MOMENTUM SOLAR 325 HIGH STREET, METUCHEN, Nl 08840 732)902-6224 MOMENTUMSOLAR.COM STRUCTURAL ENGINEERING EIVgF No.806 ST SOLAR CONTRACTOR CAMERON CHRISTENSEN CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER: CVC57036 MOMENTUM SOUR 5728 MA30R BLVD. SUITE 307 ORLANDO FL. 32819 INFORMATION VENKATARAMA NAMPALLY SYMBOL LEGEND S21 RED ROSE LN SANFORD, FL 32771 MSP MAIN SERVICE PANEL CHIMNEY 772) 359-3550 PV SYSTEM SP SUB -PANEL SKYLIGHT INFORMATION O UTILITY METER z VENT SYSTEM SIZE (DC): 7.875 KW 25 MODULES: HANWHA Q.PEAK DUO AC BLK-G5 315 DISC AC DISCONNECT Q PIPE VENT 25 INVERTERS: ENPHASE IQ7-60-2-US UDC UTILITY DISCONNECT FAN LC LOAD CENTER CJ SATELLITE DISH PROJECT INFORMATION I INITIAL DATE: 11/30/2018 DESIGNER: AC EdNEMA 3R BOX W/ ENVOY-S FIRE SETBACKS AS PER 6TH REV: EDITION 2017 FFPC DATE: DESIGNER: CB COMBINER BOX MIN TxT GROUND ACCESS POINT REV: DATE: DESIGNER: PANEL LAYOUTMODULEPITCHDIRECTION WIND PRESSURE ZONE LINES. REFER TO P V - 2PV-2.2 FOR ADDITIONAL INFO R1 - ARRAY 1 LAYOUT DETAIL SCALE: 1/8" = 1'-0" TILT: 26' AZIMUTH: 179° SHADING: 99% H . 3' 1? SOLAR INSTALLER NOTES: NO ADDITIONAL STRUCTURAL SUPPORT REQUIRED R2 - ARRAY 2 LAYOUT DETAIL SCALE: 1/8" = 1'-0" TILT: 26° AZIMUTH: 359° SHADING: 97% SOLAR INSTALLER NOTES: NO ADDITIONAL STRUCTURAL SUPPORT REQUIRED 3'-11" momentum SOLAk PRO CUSTOM SOLAR LLC D.B.A. MOMENTUM SOLAR 325 HIGH STREET, METUCHEN, N) 08840 732)902-6224 MOMENTUMSOLAR.COM EN GENSF No. 80 3 TA - S ONAl- SOLAR CONTRACTOR CAMERON CHRISTENSEN CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER: CVC57036 MOMENTUM SOLAR 5728 MAJOR BLVD. SUITE 307 ORLANDO FL. 32819 CUSTOMER INFORMATION VENKATARAMA NAMPALLY S21 RED ROSE LN SANFORD, FL 32771 772) 359-3550 PV SYSTEM INFORMATION SYSTEM SIZE (DC ): 7.875 KW 25 MODULES: HANWHA Q.PEAK DUO BLK-G5 315 25 INVERTERS: ENPHASE IQ7-60-2-US PROJECT INFORMATION INITIAL DATE: 11/30/2018 DESIGNER: AC REV. DATE: DESIGNER: REV: DATE: DESIGNER: LAYOUT DETAIL PV-3 PV MODULE RATINGS MODULE MAKE HANWHA MODEL Q.PEAK DUO BLK-G5 315 MAX POWER 315W OPEN CIRCUIT VOLTAGE 40.29V MPP VOLTAGE 33.46V SHORT CIRCUIT CURRENT 9.89A MPP CURRENT 9.41A NUMBER OF MODULES 25 UL1703 COMPLIANT YES INVERTER RATINGS VOLTAGE DROP CALCULATIONS INVERTER MAKE ENPHASE FORMULA USED PER NEC 2014 HANDBOOK 215.2(A)(4) WHERE APPLICABLE MODEL IQ7-60-2-US WIRE RUN VMP I'P R L (FT) V, % VD WIRE SIZE MAX OUTPUT POWER 240W BRANCH TO J-BOX 240.00 13 1.98 85.58 4.406 1.84% 12 AWG OPEN DC VOLTAGE 48V J-BOX TO LOAD CENTER 240.00 NOMINAL AC VOLTAGE 240V LOAD CENTER TO AC DISCONNECT 240.00MAXACCURRENT1A CEC INVERTER EFFICIENCY 97% AC DISCONNECT TO INTERCONNECTION 240.00 NUMBER OF INVERTERS 25 UL1703 COMPLIANT YES OF MODULES PV BREAKER THIS SOLAR PHOTOVOLTAIC SYSTEM COMPLIES WITH THE 2017SUBPANELPERBRANCH BREAKER SIZE FLORIDA BUILDING CODE AND THE 2014 NATIONAL ELECTRICAL CODE UP TO 16 20A 25 HANWHA Q.PEAK DUO BLK-GS 315 315W MODULES PAIRED WITH 25 ENPHASE IQ7-60-2-US MICRO -INVERTERS 25 1.24 50.00 3.100 1.29% 10 AWG 31.25 0.778 3.00 0.146 0.06% 08 AWG 31.25 I 0.778 I 10.00 I 0.486 I 0.20% 120% RULE BUS RATING x 1.2) MAIN BREAKER = BACKFEED AVAILABLE 200A x 1.2) - 200A = 40A BACKFEED AVAILABLE BRANCH CIRCUIT A 12 MICRO -INVERTERS BRANCH CIRCUIT B UTILITY 13 MICRO -INVERTERS METER GRID ENPHASE 80A AC COMBINER SOLAR CIRCUIT BOX DISCONNECTING MEANS f f `/' SQUARE-D 60A FUSIBLE AC DISCONNECT 8 8 2ooA 40A SOL.ADECK 10A BREAKER 0POWER JUNCTION (ENVOY) 40A FUSES -7_7 GROUND 1 BOX 2A-B 20A BREAKER (A) 3 3 EXISTING 200ATERMINATIONCAP20ABREAKER (B) INSTALLED ON METER MAIN END OF CABLE 200A BREAKER 08 AWG EXISTING SUB PANEL 240 V momentum SOLAR PRO CUSTOM SOLAR LLC D.B.A. MOMENTUM SOLAR 325 HIGH STREET, METUCHEN, NJ 08840 732)902-6224 MOMENTUMSOLAR.COM STRUCTURAL ENGINEERING 1,j1\III II I111111/j, R P c,Q E Ns •. No. 8065 ATE n COW Y•7 w_\:Z•L•liItC • : CAMERON CHRISTENSEN CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER: CVC57036 MOMENTUM SOLAR 5728 MAJOR BLVD. SUITE 307 ORLANDO FL. 32819 CUSTOMER INFORMATION VENKATARAMA NAMPALLY 521 RED ROSE LN SANFORD, FL 32771 772) 359-3550 INFORMATION SYSTEM SIZE (DC ): 7.875 KW 25 MODULES: HANWHA Q.PEAK DUO BLK-G5 315 25 INVERTERS: ENPHASE IQ7-60-2-US Wire Tag Conduit Wire Qty Wire Gauge Wire Type Temp. Rating Wire Ampacity (A) Temp. Derate Conduit Fill Derate Derated Ampacity (A) Inverter Qty NOC (A) NEC Correction Design Current (A) Ground Size Ground Wire Type 1 OPEN AIR 2 12 AWG Trunk Cable 90°C 30 0.96 1 28.80 13 1 1.25 16.25 12 AWG Trunk Cable INITTIAL 2A 1" PVC 2 10 AWG THWN-2 90°C 40 0.96 0.8 30.72 12 1 1.25 15.00 08 AWG THWN-2 REV: REV: 2B 1" PVC 2 10 AWG THWN-2 90'C 40 0.96 0.8 30.72 13 1 1.25 16.25 08 AWG THWN-2 3 1" PVC 3 08 AWG THWN-2 75'C 50 0.96 1 48.00 25 1 1.25 31.25 08 AWG THWN-2 PROJECT INFORMATION DATE: 11/30/2018 DESIGNER: AC DATE: DESIGNER: DATE: DESIGNER: ELECTRICAL PV-4 ELECTRICAL NOTES: 1, ALL CALCULATIONS FOR VOC, VMAX, IMP AND ISC HAVE BEEN CALCULATED USING THE MANUFACTURED STRING CALCULATOR BASED ON ASHRAE 2% HIGH AND EXTREME MINIMUM TEMPERATURE COEFICIENTS. 2. THE ENTIRE ARRAY IS BONDED ACCORDING TO (NEC 690.46 - 250.120 paragraph C), THE GROUND IS CARRIED AWAY FROM THE GROUNDING LUG USING #6 BARE COPPER WIRE. 3. THIS SYSTEM COMPLIES WITH NEC 2014 4. BRANCH CIRCUIT CALCULATION FOR WIRE TAG 1 DISPLAYS THE LARGEST BRANCH CIRCUIT IN SYSTEM. OTHER BRANCH CIRCUITS WILL HAVE LOWER DESIGN CURRENT THAN THE ONE SHOWN. IN ADDITION, VOLTAGE DROP CALCULATIONS FROM PANELS TO THE COMBINER BOX WILL BE SHOWN IN A SIMILAR FASHION 5. ALL CONDUCTORS ARE SIZED BASED ON NEC 2014 ARTICLE 310 6. ALL EQUIPMENT INSTALLED IS RATED AT 90'C 7. INVERTER NOC (NOMINAL OPEN CURRENT) OBTAINED FROM EQUIPMENT DATASHEET 8. CONTRACTOR RESPONSIBLE FOR COMPLYING WILL ALL LOCAL OR NATIONAL CODE REQUIREMENTS AND EQUIPMENT INSTALLATION INSTRUCTIONS 9. EACH MODULE MUST BE GROUNDED ACCORDING TO SUNMODULE USER INSTRUCTIONS 10. ALL EQUIPMENT SHALL BE LISTED PER NEC 690.4(D) 11.PER NEC 690.17, PROVIDE A WARNING SIGN AT ALL LOCATIONS WHERE TERMINALS OF THE DISCONNECTING MEANS MAY BE ENERGIZED IN THE OPEN POSITION> SIGN SHALL READ 'WARNING - ELECTRIC SHOCK HAZARD - DO NOT TOUCH TERMINALS - OR EQUIVALENT, 12. PER NEC 705.10, PROVIDE A PERMANENT PLAQUE OR DIRECTORY SHOWING ALL ELECTRIC POWER SOURCES ON THE PREMISES AT SERVICE ENTRANCE. 13. INTERCONNECTION METHOD SHALL COMPLY WITH NEC 690.64 14. AND OPTION FOR A SINGLE CIRCUIT BRANCH TO BE SPLIT INTO TWO SUB -CIRCUIT BRANCHES IS ACCEPTABLE. 15. ALL CONDUCTORS MUST BE COPPER. 16. NEUTRAL AND EQUIPMENT GROUNDING CONDUCTOR BONDED AS PER NEC 250.24(C). 17. EQUIPMENT GROUNDING CONDUCTOR IS CONNECTED TO A GROUNDING ELECTRODE SYSTEM PER 250.54(D). 18. FUSES FOR PV DISCONNECT HAVE AIC RATINGS OF 200KA AC AND 20KA DC. 19. SUPPLY SIDE CONNECTION SHALL BE MADE USING ILSCO INSULATION PIERCING CONNECTORS (IPC). MAKE, MODEL, AND RATING OF INTERCONNECTION CAN BE SEEN ON TABLE 1 BELOW. 20. METHOD OF INTERCONNECTION CAN BE SEEN IN FIGURE 1. 21. UTILITY HAS 24-HR UNRESTRICTED ACCESS TO ALL PHOTOVOLTAIC SYSTEM COMPONENTS LOCATED AT THE SERVICE ENTRANCE. 22. WORKING CLEARANCES AROUND THE EXISTING AND NEW ELECTRICAL EQUIPMENT WILL BE MAINTAINED IN ACCORDANCE WITH NEC ARTICLE 110.26. 23. CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS SUNLIGHT RESISTANT PER NEC ARTICLE 300.6 (C)(1) AND ARTICLE 310.8 (D). 24. CONDUCTORS EXPOSED TO WET LOCATIONS SHALL BE SUITABLE FOR USE IN WET LOCATIONS PER NEC ARTICLE 310.8 (C). 25. TOTAL AREA OF ALL CONDUCTORS, SPLICES, AND TAPS INSTALLED AT ANY CROSS SECTION OF THE WIRING DOES NOT EXCEED 75% OF THE CROSS SECTIONAL AREA OF THE SPACE. NEC 312.8(2). 26. SYSTEM IS CONSIDERED AN AC MODULE SYSTEM. NO DC CONDUCTORS ARE PRESENT IN CONDUIT, COMBINER, JUNCTION BOX, DISCONNECT. AND COMPLIES WITH 690.6 - NO DC DISCONNECT AND ASSOCIATED DC LABELING ARE REQUIRED. 27. SYSTEM COMPLIES WITH 690.12 RAPID SHUTDOWN AND ASSOCIATED LABELING AS PER 690.56(C). AC VOLTAGE AND SYSTEM OPERATING CURRENT SHALL BE PROVIDED 690.52, 28. CONDUCTORS IN CONDUIT ARE AC CONDUCTORS BRANCH CIRCUITS AND NOT PV SOURCE CIRCUITS. 690.6. 29. ALL GROUNDING SHALL COMPLY WITH 690.47(A) IN THAT THE AC MODULES WILL COMPLY WITH 250.64. 30. NO TERMINALS WILL BE ENERGIZED IN THE OPEN POSITION IN THIS AC MODULE SYSTEM 690.17, 690.6. 31. WHERE APPLICABLE: INTERCONNECTION SHALL COMPLY WITH 705.12(D)(3), 705.12(D)(2)(3)(B), 705.12(A) AS PERMITTED BY 230.86(6) TABLE 1: MAKE MODEL VOLTAGE CONDUCTOR CONDUCTOR RATING RANGE MAIN RANGE TAP ILSCO IPC 4020 600 V 4/0-4 AWG 6-14 AWG ILSCO IPC 4006 600 V 4/0-2 AWG 2/0-6 AWG FIGURE 1: 1.Adjust the connector nut to suitable location 2.Put the branch wire 3.Insert the main wlre,if there are SOLAR PRO CUSTOM SOLAR LLC D.B.A. MOMENTUM SOLAR 325 HIGH STREET, METUCHEN, NJ 08840 732)902-6224 MOMENTUMSOLAR.COM STRUCTURAL ENGINEERING SOLAR CONTRACTOR CAMERON CHRISTENSEN into the capsheeth fully two lays of insulated lay in the main CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER: CVC57036 cebles,should strip a certain length MOMENTUM SOLAR 5728 MAJOR BLVD. SUITE 307 of the first insulated lay from inserted ORLANDO FL. 32819 4.Turn the nut by hand,and S.Screw the nut with the sleeve fix the connector In suitable spanner. location B.Screw the nut continually until the top part Is cracked and dropped down. CUSTOMER INFORMATION VENKATARAMA NAMPALLY 521 RED ROSE LN SANFORD, FL 32771 772) 359-3550 SYSTEM SIZE (DC ): 7.875 KW 25 MODULES: HANWHA Q.PEAK DUO BLK-G5 315 25 INVERTERS: ENPHASE IQ7-60-2-US I PROJECT INFORMATION I IINITIAL IDATE: 11/30/2018 (DESIGNER: AC I IREV: IDATE: IDESIGNER: I IREV: IDATE: IDESIGNER: I ELECTRICAL PV-4.1 TAG LABEL QUANTITY LOCATION NOTE EXAMPLES momentum SOLAR O 1 MAIN SERVICE PANEL POINT OF INTERCONNECTION O PRO CUSTOM SOLAR LLC D.B.A. MOMENTUM SOLAR 325 HIGH STREET, METUCHEN, NJ 08840 732)902-6224 MOMENTUMSOLAR.COM STRUCTURAL ENGINEERING a© .- f SOURCES.• THIS .. . OVERCURRENT DEVICES.. MAIN SUPPLY PHOTOVOLTAIC SYSTEM OVERC- EQUI PED WITH EXCEED AMPACITY OF BUSBAR. RAPID SHUTDOWN 1 COMBINER BOX 1 AT ANY JUNCTION BOX OR DCALLCOMBINERIFUSED11II)))I P r NO. 80653 = A a * - OFT - 44, AWARNING_ OC 06 • • • • TERMINALS ON BOTH LINE AND 1 JUNCTION BOX 1 AT ANY JUNCTION BOX OR DC COMBINER IF USED G S/(N - SIDES MAY BE ENERGIZED IN THE OPEN POSITION PHOTOVOLTAIC AC DISCONNECT AWARNINGI SOLAR CONTRACTOR O OPERATING CURRENT25.00A ELECTRICAL • - . NOT• OPERATION • • . ENERGIZED IN THE OPEN •POSITION PHOTOVOLTAIC SYSTE====' Tiv-SrDISCONNECT HIGH STREET 1 AC DISCONNECT 1 OF EACH AT FUSED AC DISCONNECT COMPLETE VOLTAGE AND= CURRENT VALUES ON LABEL325 i ;, CAMERON CHRISTENSEN CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER: CVC57036 SOLA57O28ENTUMMA)OR BL DR SUITE 307 ORLANDO FL. 32819 CUSTOMER INFORMATION VENKATARAMA NAMPALLYMETUCHEN, NJ "4 1 Op 521 RED ROSE LN SANFORD, FL 32771 772) 359-3550 a PV SYSTEM INFORMATION DUAL POWER SOURCE SECONDO• -PHOTOVOLTAICE1 SYSTEM MAIN DISCONNECT PANEL 1 OF EACH AT BUILDING MAIN DISCONNECT PANEL SYSTEM SIZE (DC ): 7.875 KW 25 MODULES: HANWHA Q.PEAK DUO BLK-G5 315 25 INVERTERS: ENPHASE IQ7-60-2-US RATED •. OPERATING CURRENT O PROJECT INFORMATION INITIAL DATE: 11/30/2018 DESIGNER: AC O A . - POWERDUALSOURCE SYSTEM 1 UTILITY METER 1 AT UTILITY METER ru a!a ., m w f REV: DATE: DESIGNER: REV: DATE: DESIGNER: EQUIPMENT LABELS PV-4.2 Daniel W. DUnzik Architect LEED-AP 370 Burnt Hill Rd. Skillman, NJ. 08558 908-872-3664 Studiogdesign@comcast.net November 29, 2018 Sanford, FL Attn: Construction Official Re: Proposed Photovoltaic Solar Panel Installation Venkatarama Nampally 521 Red Rose Ln. Sanford, FL 32771 Dear Sir: Certification: I have reviewed the engineering testing reports for the racking and attachments to be used on this project and I certify that the products are capable of supporting the code required loads and are suitable for this installation when installed in strict compliance with the manufacturers printed instructions. Regarding the solar panel array installation on the above referenced project please note that An inspection was performed and analysis of the existing structure was conducted. There is adequate structural capacity for the installation of the array with the following recommendations: 1. The array will be installed on the existing roof. The roof is constructed of 2"x4" wood trusses @ 24" O.C. spanning 121" with a top chord length of 15' with intermediate supports at 1/2 points making the effective longest span 79" with 1/2" OSB plywood sheathing. The new array (See Site map by contractor) will add 2.63 Lb. / Sf. overall to the roof. No additional structure support is required for the existing roof structure. 2. The system shall be secured to the roof using the "Ecofasten Solar" "Rock -IT" ® attachment system. The installation shall be in strict compliance with manufacturers printed instructions. The attachment system shall be UL 1703 approved tested. The attachments shall be min. 5/16" x 4" long stainless -steel lags with a min. embedment of 3.25" into the rafters. Attachments shall be @ 48" o.c. Max. in roof wind zone 1 and @ 24" o.c. Max. in roof wind zone 2 and 3 lags to alternate rafters. Provide 6 mil. vapor barrier between dissimilar metals. Provide water tight gasket and sealant at all penetrations. Attachments shall follow panel rows as specified by the system manufacturer's installation manual. The panel angle shall match the roof slope. Structural Design Loads per ASCE 7-10 Dead Loads = 10 psf (+2.6psf, New Solar Panels) = 12.6 psf.- Live Load =20psf Total dead weight on attachment = 19Lb. Max. Ch. 30 Wind Loads Components and Cladding windloads = 140 mph Exposure B zone 1=+/- 31.4 psf., Zone 2&3=+/-77.7psf. Area of Panels largest array = 452.4sf Tributary area panels/attachment max. 452.4sf/ 56min = 8sf. Min Number of Attachments =56. Wind pressure 31.4 x Area 452.4/ 56 No. Attachments = 627 TABLE 10.3.1 NDS Pull out strength of 5/16"x4" lags in rafter =W'= WxCdxCt=2661bs/in embedment x 3.25"embedment = 864.5 x1.6Cd xLOCt = 1,383 Lbs Max. > 6271bs/attachment Daniel W. Dunzik Architect LEED-AP 370 Burnt Hill Rd. Skillman, NJ. 08558 908-872-3664 Studiogdesigns@comcast.net OK 3. Solar modules shall be UL-1703 rated. Refer to manufacturers specifications sheets. 4. Positive drainage of the system shall be so as not to void the existing roof warrantee. 5. Florida Administrative Code, 2017 Florida Building Code - Residential Sixth Edition, ASCE-7-10, 2017 Florida Building Code — Energy Conservation, Sixth Edition, 2014 National Electric Code, All Local Governing County and Municipal Ordinances adopted by reference or enacted by law. All components used meet the criteria of the Florida Solar Energy Center. If you have any questions relating to this matter, please contact me at your earliest convenience. Thank you. Digitally signed by: Daniel W. G,F• F O,Q Dunzik P'•• •• DN: CN = Daniel W. Dunzik N E W / U Z •. email = 1. — ' • STUDIOGDESIGN@COMCAST. AR98795. •' NET C = AD O = RA. LEED-AP Ci'••. .•• OU = FI. Lin. No.AR98795 Fh'ED P G Date: 2018.11.29 15:18:37 - 05'00' Daniel W. Dunzik, RA. LEED-AP FL. Lic. No. AR98795 E O•F F O NOEL W. p r t AR9 7 5 f G RED ARG Daniel W. Dunzik . Architect LEED-AP 370 Burnt Hill Rd. Skillman, NJ. 08SS8 909-872-3664 January 29, 2018 Building Department Attn: Plan Reviewer Re:Proposed Photovoltaic Solar Panel Installation Dear Sir: I have reviewed the following documents related to the "EcoFasten Solar" ROCK -IT SYSTEM 4.0 and certify that the attachment system when installed in strict compliance with the manufacturers Installation Manual appropriate for this application and is in compliance with the latest building codes including Florida Administrative Code, 2017 Florida Building Code - Residential Sixth Edition, ASCE-7-10, 2017 Florida Building Code — Energy Conservation, Sixth Edition, 2014 National Electric Code, All Local Governing County and Municipal Ordinances adopted by reference or enacted by law. I make this certification for the following listed documents: 1. ROCK -IT SYSTEM 4.0 Installation Manual 2. PZSE, Inc Structural Engineers Certification. 3. EcoFasten Solar Certificate No. US 82150026 4. ROCK -IT SYSTEM 4.0 Cut Sheet for Coupling, Hybrid Coupling, and Mount. If you have any questions relating to this matter, please contact me at your earliest convenience. Thank you. Daniel W. Dunzik, RA. LEED-AP Fl. Lic. No. AR98795 Daniel W Dunzik..., Digitally, signed by: Daniel W. Daniel W. Dunzik idi,?bdesign@comcast.net D O = Lic No AR98795 ArchitectJ ite: 2018.01.29 18:19:35 - 05'00' OF F4 AIEL W. U 7 R9a795 FD AFtG The new Pt, A t-?u,` solar module from Q CELLS impresses with its outstanding visual appearance and particularly high performance on a small surface thanks to the innovative Q,ANTUh:q 111.10 Technology. Q.ANTUM's world -record -holding cell concept has now been combined with state-of-the-art circuitry half cells and a six -bulbar design, thus achieving outstanding performance under real conditions — both with low -intensity solar radiation as well as on hot, clear summer days. Q,ANTUM TECHNOLOGY. LOW LEVELIZED COST OF ELECTRICn-Y Higher yield per surface area, lower BOS costs, higher power classes, and an efficiency rate of up to 1%3 %, INNOVATIVE ALL-WEATHER TECHNOLOGY Optimal yields, whatever the weather with excellent low -fight and temperature behavior. ENDURING HIGH PERFORMANCE Long-term yield security with Anti LID TechnotoW, QQW Anti PID Technology', Hot -Spot Protect and Traceable Quality Tr&Qlm. TOW WAM PIV EXTREME WEATHER RATING High-tech aluminum alloy frame, certified for high snow 018 5400 Pa) and wind loads (4000 Pa) regarding I EC, A RELIABLE INVESTMENT Inclusive 12-year product warranty and 25-year linear performance guarantee', w. STATE OF THE ART MOCKJLE TECHNOLOGY Q.ANTLIM DUO combines cutting edge cell separation and innovative wiring with Q.ANTUM Technology, APT test conditions according to I 62804-1:2015, method 8 (-1500V, 168h) See data stunt on rear W furthet THE IDEAL SOLUTION FOR- infomiaWn. Engineered in Germany OCELLS Fes 66.3in x 39,4 n x 1,261n (including firrinned 1(>85mrn x 1000mm x 32mm) W041111 4 1 . 2 1hit (18, 7 kg) Frond Carof 0,13 in (3.2nim) thermally pee -stressed glass with anti -reflection lechnuirafy Racy Cover Corripro; to film hams Back anodized lilurninum Cell 6 x 20 rronticrystallinic Q.ANTUM lacar half -cells luircHan bw 2,763,35 n x 1,97-2,76 n x 0,51-0..83 r ii 70-85 turn x 50-70 rrm x 13-? 1 men), doceptralized, IP67 Cable 4mmR Solar cable; (+) c,433 m (II 00-mm), (-) A43-1 in (1100mm) CanallMuifi-06ntaict MCC, IP68 T -E7.3)1-4— POWER CLASS 300 305 310 315 320 MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS, SIC (POWER TOLERANCE 5 W / -0 W) Pe at MVP Prom [w) 300 305 310 315 320 Sheri chcou Con lid' 6 JAI 932 9,78 9,83 9.89 9,94 opt" croevil Valois va IV) 39,48 39,75 40.02 40,29 40.56 CWMM at Min 1.11 [Al 9,25 9.31 9,36 9,41 9,47 V04416 at RAPPV_ IV) 32,43 32.78 3312 33,46 33.80 Efficuraf; y, T 1%] z17.8 IH I a 18,4 18,7 MINIMUM PERFORMANCE AT NORMAL OPERAVAR C(INDITIONS, KMOTI parval all MPP fa,o 1WI 224 1 227,8 231,6 235,3 239,1 V, shwt Curl Cast 1sc (firl 7,83 Za 7.92 7,97 8,01 open almuct Y V IV) 37,15 37,40 37.66 37.91 38,17 C at atM"ice„[A] 7.28 7,32 7,37 7,41 7,45 waftse & I INPIP v— IV] 30,78 31.11 31.44 31.76 32,08 Wnswamani tofwanre P- %, I., r STG: 1000W,W 26. 2'C, AM I 6G .-v<lmg B. iEC &GOD4-3 '500 W)W, NN1,011, ptr.. AM 1 5 GQ CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE I IN At I aM98 % of f am i noipool during first year. Thenufter max- 0,54% delgradation par year At Iran 93.1 % of W mai piree, up to 10 years - At lent 85 % of rominal power up to 26Force, Air data wAtun memutomei t lowwm. Ft., 1 warranties in accordance With the, warranty terror of the Q CELIS sales ownizator, of your reap live Country. Typical module parkarnance under low anallaince coirtiurns in ramie risen to STC condition (25'C, 1000W/Wr TEMPERATURE COEFFICIENTS Tempailiture Caeftf%&A of 6, a K) +0,04 Covall of V. t%/K) —0.28 Teraparaturs coesideal of P— y I%/KI —0.37 Normal Operabag V042N Temptralroe KMOT rrl 109*5,4 (43 *3C) MRAMUN yslew voltage V,, Pill 1000 0 EQ / 1000 (LJ Q smility Clog 11 ftrzi= a Series Faso Ratfurg A DC1 20 Pro Raftj G 0 EQ /TYPE I (UQ Max Design Lsada louo, f Pull Ulkyl Iftil 75 (3600 FA) 155 (2667 Pa) Pefrafted madvirt larlopowwre 40°F up to +185*F an confistalits do" 40'C up to +85C) Max, 18ift Load, pleb I Pull JUL F113 (5400 Pal 184 (4000 PR) I see Installation manual Enphase IQ 7 and The high-powered smart grid -ready Enphase IQ 7 Micro" and Enphase IQ 7+ Micro" IQ 7+ dramatically simplify the installation process while 0 achieving the highest system efficiency. Microinverters UL To learn more about Enphase offerings, visit enphase.com Part of the Enphase IQ System, the IQ 7 and IQ 7+ Microinverters integrate with the Enphase IQ Envoy", Enphase IQ Battery", and the Enphase Enlighten" monitoring and analysis software. IQ Series Microinverters extend the reliability standards set forth by previous generations and undergo over a million hours of power -on testing, enabling Enphase to provide an industry -leading warranty of up to 25 years, Lightweight and simple Easter installation with improved, lighter two -wire cabling Built-in rapid shutdown cornphant (NLC 2014 & 2017) Productive and Reliable optimized for high powered 60-(.,,ell and 12-cell* modules More than a million hours of testing Class 11 double -insulated enclosure UL listed Smart Grid Ready Complies with advanced grid support, voltage and frequency ride -through requirements Remotely updates to respond to changing grid requirements Configurable for varying grid profiles Meets CA Rule2l (UL 1741-SA) IT,ie 10 Micio is required to suppw! 1`2 cell modules ENPHASE. 09f Enphase IQ 7 and I + Microinverters INPUT DATA (DC) IQ7-60-2-US i IQ7-60- -US I 7PLUS-72-2-US f IQ7PLU -72- -US Commonly used module pairings' 235 W - 350 W + 235 W - 440 W + Module compatibility 60-cell PV modules only 60-cell and 72-cell PV modules; Maximum Input DC voltage 48 V 60 V Peak power tracking voltage 27 V - 37 V 27 V - 45 V Operating range 16 V - 48 V 16 V - 60 V Min/Max start voltage 22 V 3 48 V 22 V ,' 60 V Max DC short circuit current (module Ise) 15 A 15 A Overvolt age class DC port 11 II DC port backfeed current 0 A 0 A PV array configuration 1 x 1 ungrounded array; No additional DC side protection required; AC side protection requires max 20A per branch circuit OUTPUT DATA (AC) IQ 7 Mioroinverter IQ 7+ Microiaverter Peak output power 250 VA 295 VA Maximum continuous output power 240 VA 290 VA Norninal (L-L) voltage/rangel 240 V / 208 V r` 240 V 1 208 V / 211-264 V 183-229 V 211-264 V 183-229 V Maximum continuous output current 1-0 A (240 V) 1.15 A (208 V) 1-21 A (240 V) 1,39 A (208 V) Nominal frequency 60 Hz 60 Liz Extended frequency range 47. 68 Liz 47 - 68 Hz AC short circuit fault current over 3 cycles 5.8 Arms 5-8 Arms Maximum units per 20 A (L-L) branch circuit' 16 (240 VAC) 13 (208 VAC:) 13 (240 VAC} 11 (208 VAC) Overvoltage class AC Dort III III AC port backfeed current 0 A 0 A Power factor setting 1.0 1,0 Power factor ad astable) 0.71eadinj ... 0.7 lay, l irr° 0.7 leading ... 0.7 laggin EFFICIENCY @240 "V' 208 'V 1a 240 V @208 V Peak CEG efficiency 97 6 `C 976 % 97-5 % 97.3 % CEC weighted efficiency 97.0 % 97.0 °A 97.0 % 97 0 % MECHANICAL DATA Ambient temperature range a........-......,.........- ... .............-..,... _....._........-,_ 400C to 65"C Relative humidity range 4r to 100% (condensing) Connecter type (IQ7-60-2-US & IQ71PLUS-72-24)S) MC4 (or Amphenol H4 UTX with additional Q-DCC',-5 adapter) Connector type (W-60.13-US & IQ7PL.US-72-0-US) Friends PV2 (MC4 intermateable). Adaptors for modules with MC4 or UTX connectors: PV2 to MC4: order ECA-S20-S22 PV2 to UT X: order EGA-S20-S25 Dimensions (WxHxD) 212 mrn x 175 rnrn x 30.2 rmam (without bracket) Weight 1-08 kg (2-38 Ibs) Cooling Natural convection - No fans Approved for wet locations Yes Pollution degree PD3 Enclosure Glass 11 double -insulated, corrosion resistant polymeric, enclosure Environmental category r' UV exposure rating NFMA Type 6 / outdoor FEATURES Communication Power tine Conimunicatior (PLC) Monitoring Enlighten Manager and MyFrmlighten monitoring options, Both.options require installation of can Enphase IQ Fnvoy. Disconnecting rneans The AC and DC connectors have beerr, evaluated and approved by UL for use as ttte load -break disconnect recic,ired by NFC 690, Compliance CA Rule 21 (LiL- 1741-SA) UL 62109.1, U1, 1741,/1EE171547, FCC Part 15 Class B. ICES-0003 Class Ey, CAN/GSA-C22-2 NO. 107.1-01 This product is W t-tsted as PV Rapid Shut Down Equipment and conforms With NEC-2014 and NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Sbutdown of PV Systems, for AC and DC conductors, when installed according manufacturer's instructions. t. No enforced LAG?AC, rat€o. See the cornf? ti:aiEity ealeuia€ar airiSiygppQrt.`,rnQdk1Ie-i- iripE2at1 #Ilty 2 Nominal voltage range can be extended beyond nominal it required by the utility 3 Limits may vary . Refer w local sequirernents io define time ?wrnder of microinve,ters fre, hra.ic:n In your area To learn more about Enphase offerings, visit enphase,com PHASE. f ' 1'-,< ets.v I'3vr`t=o!t_c.<=c. Alt a,:tr-r4_ rz,ra+._, t. c°t'r„i_;: 1 . Installation to be completed in accordance with manufacturer's written specifications and installation instructions, 2. See spec sheet or contact manufacturer for detailed material, finishes, and configuration options, I Contact manufacturer for detailed layout, 4. Do not scale drawings. 5. Subject to change without notice, 2.62in 2.14ir L51.38mm '54.37mm.i 32mm 35mm A V4 7 ',- --asten Solavr', Ecol I 2.34ir 40mm 4741 W Polk Stree Ste. 4 Phoenix, AZ 85043 Toll Free Phone 1 ,888,766,4273 Toll Free Phone 1,877.8593947 Material: See Spec SheetTollFreeFax1,888,766,9994 Toll Free Fax 1,888,766,9994 kale: 1:4 6128/2017 ASG: - EF$: x 1 , Installation to be completed in accordance with manufacturer's written specifications and installation instrucWns, 2. See spec sheet or contact manufacturer for detailed material, finishes, and configuration options. 3, Contact manufacturer for detailed layout. 4, Do not scale drawin 5Subject to change wIltshout notice. 7. 00in it 77.80mm 1 2, 02in 51. 38mm-" 32mm 2, 14in 154. 37mm L -! 35mm 5, 00in 127mm] 2. 34in 1, 59.36mml 1, 40mm E v " *1, I4741 W Polk Street Ste, 4 EcoFastenSolarS"=GUARDS' I K, Phoenix, AZ 85043 Toll Free Phone 1,888,766.4273 Toll Free Phone 1.877,859,3947 Material, See Spec Sheet Toll Free Fax 1 3881W9994 Toll Free Fax 1,888.766,9994 : Scale: 11 6/2812017 ASG- - EFS: x K-IT 5Y t EM'4.0 RAIL -FREE RACKING 1 1 , 1 ExoFasten Solall A C,-,>EcoFasten Solar®R V Qk Committed to the connection Contents Pg. 1 P. 2 P, Pg, 6 P. 7 Assets of Design Features System Components Rock -it 4.0 Coupling Assembly iY iJi i47 IYlVU11C A'iZ11Z111 Ri EY Rock -It Clip SS Assembly Rock -It Clip 2.0 Assembly Array Layout GreenFasten Flashing Install Rock -it System 4.0 Install Ground Lug Install Rock®it Cii S install Rock -it Clip 2.0 Install Pg. 8 -12 Standoff Spacing Tables Snow Load 0-20 psf Snow Load 21-30 psf Snow Load 31-40 psf Snow Load 41-50 psf Snow Load 1-60 psf Pg. 13 _ _ _ _ Grounding Information Bonding Assembly and Bonding Path Pg. 14 _ _ _ _ Thermal Expansion and Bonding Bracket Spacing Staggered Layout Cantilever Pg. 15-16 System Specifications Evaluated, Compatible Modules ROCK -IT SSTeM 4.0 EcoFasten Solar specializes In solar roof attachments that are fast and easy to Install, straightforward, secure and cost- effective. EcoFasten offers a wide variet),,, rUll il i i A I ! ; 43 for all of your rooftop anchoring needs. Products are rigorously tested and approved above and beyond industry standards in-house and by third party agencies. EcoFasten's patented conlcal sealing system has been In service in the snow guard and solar industries for two decades. FeaTures New and improved design Fastest, easiest to level system on the market Integrated electrical bonding SIMPLE- only 4 components North - South adjustability Only one tool required (1/2"cleep well socket) Vertical adjustment of 3"A' SYSTem componenTS* - reouireD It ROCK - IT SLIDe ROCK -IT 4.0 ROCK -IT 4.0 coupunG 4' For comp sHinGLe mounT & LoaD BearinG FOOT 8' For TILe SYSTem componenTS* - OPTIonaL 77 211 7 ROCK - IT CUP SS Ref= er PG, 6) ROCK - IT 4,0 H JBI-U mounT ROCI- IT CLIP 2,0 ReFer TO PG, 6) 4 EcoFasten Solar Ecof` astvi Solar products are protected by the following US. Patents: 8, 151,522 8,153,700 8,181,398 8,166,713 8,146,299 ROCK - IT 4,() 8,209,914k245,454 8,272,174 8225557 9,010.038Arrag SKII-T 9,134,040 9,175,478 9,212433 Eno caps EnD caPs come Pre- r')STau-eD on EaST E' nD OF SKIrT SeCTIOnS) Components for use with 32mm modules are available as special order. Components for use with 32mm modules are labeled as such on system packaging, Please refer to evaluated, compatible modules grid on page 15 to identify system compatible 32mm modules, www. ecofastensolar,corn lnfo@ecofastensolar.com 877-859-3947 11 www.ecofastensolar.com ROCK -IT 4.0mounT ASseMBLY N C)Te: lTerTis 1-7 SHIP asseM B ,--e D 1 5/16"-18 x 1,75"Hex Serrated Flange Bolt 300 Series SS 2 Rock -It 4.0 Mid -Clamp 6000 Series AL 3 Rock -It 4.0 Shelf 6000 Series AL 4 Flange Level Nut 300 Series SS 5 Rock -It 4.0 Te Plate 6000 Series AL 6 Rock -It Pedestal 6000 Series AL 7 5/16"-18 x 3/8" Hex Serrated Flange Bolt 300 Series 55 8 3/8" ID Star` asher 300 Series SS 9 3/8"-16 x 3" Hex Tap BOIL 300 Series SS ROCK-41 SUDes are accePTaBLe E3r aCKP IS F,_)r useWITH R00---IT 4,C) separaTe(_,,4) ROCK -IT 4.0 COUPLINGassemBLY NOTe: ITems i-3SHIP assemDLeD 1 5/16"-1 8 x 1 .75'Hex Serrated Flange Bolt 300 Series SS 2 Rock -it 4.0 Coupling Mid -Clamp 6000 Series AL 3 Rock -It 4,0 Coupling Shelf 6000 Series AL 4 Rock -it Load Bearing Foot Clip 5 Rock -It Load Bearing Foot Base infD@ecofastensolar.com 877-859-3947 2 ROCK -IT 4.0 HYBRIDmounT ASseMBL9 NOTe: ITems i-ioSl-lip asSeMBLeD ROCK -IT CLIP SS ASseMBLY NICTE_?: I -CMS 1 3 SHIP aSSeMBLO-D 1 Stainless Steel Carriage Bolt - 313-18X,75 2 Rock -It Clip SS 3 Stainless Steel Flange nut,313-18 Will405, 1 Rock -It 4.0 Shelf 6000 Series AL 2 Rock -It 4.0 Coupling Mid -Clamp 6000 Series AL 3 Rock -it 4.0 Coupling Tie Plate6000 Series AL 4 Flange Level Nut 300 Series SS 5 Rock -it Pedestal 6000 Series AL 6 Rock -It Slide 6000 Series AL 7 3/8"-16 x 3"HexTap Bolt 300 Series SS 8 3/8'ID Star Washer 300 Series S 9 5/16"-18 x 3/8' Hex Serrated Flange Bolt 300 Series SS 10 5/16'-18 x 1 .5" Hex Serrated Flange Bolt 300 Series SS ROCK -IT CLIP 2,0 ASseMBLY Nc)Tel [TeMSI-3 SHip assemE3L__eD 1 Rock -it Clip ZO 2 Stainless Steel Flange nut .313-18 3 Bolt 3125-18x 1 x1 -5 www.ecofastensolar.com info@ecofa5tensolar.com 877-859-3947 3 Arr LT Find the required structural attachment points. Mark these using a vertical (N-5) chalk line on the center of the rafters. Spacing may vary depending upon project specific structural requirements; i.e. high snow and wind load areas may require lesser bracket spacing in the E-W axis vs, the maximum spacing. Max spacing is 48"for portrait orientation and 72'for landscape orientation. Consult project layout diagram for project specific bracket spacing on the roof. Install Rock -It Mounts to predetermined mount spacing. The Rock -it Array Skirt sections are the width of a typical 60 cell module — use the Rock -it Array Skirt as a guide to lay out module placement. Note: The distance between the rows of mounts is calculated by the module dimension N-S plus 1 3/8" 35mm). Lag screw should be installed as close to center of exposed shingle as possible. The minimum distance between the lag screw and the edge of the shingle Is 1/2". GreenFaSTen"" FLEISHnG inSTaLL vertical lines to mark the installation position for each GreenFasten flashing, 2 Drill a pilot hole (1/4"dia meter) for the lag bolt. Backfill with sealant EcoFasten Solar recommends an EPDM mastic. 3 Insert the flashing so the top part is under the next row of shingles and pushed far enough up slope to prevent water infiltration through vertical joint in shingles. The leading edge of flashing must butt against upper row of nails to prevent turning when torqued, 4 Line up pilot hole with GreenFasten flashing hole. Insert the lag bolt through the EPDIVI bonded washer, the Rock -it slide, the gasketed hole in the flashing and into the rafter, Torque: The range is between 100-140 torque inch -pounds depending on the type of wood and time of year. The visual indicator for proper torque Is when the EPDM on the underside of the bonded washer begins to Push out the sides as the washer compresses. If using an impact wrench to install the fasteners be careful not to over torque the fastener. You may need to stop and use a ratchet to finish the install, The Engineer of Record shall check capacity of rafter to support lag screw loading, www. ecofastensolar.com info@ecofastensolar.com 877-859-3947 4 Install EcoFasten Solar Flashing with Rock -it mounts Follow EcoFasten Solar Install Instmcdom for (lashing and bracket fristall (Gatenfiarten *a" above), Optimum vertical distance between log bollo Is I 3/rplusmodule dirraonsfort, Set mounts on ears rotor raw so that the Rodc4t Pedestal Is on the South end of Pock-ft 91da, Set mounts on aII upper moe; sot the Rock -it Pedestal Is on ft North end of Rack -ItSlide 2 Install Rock -it Array Skirt onto Eave MountsSlideRock -it Array Skirt Into front channel on Rock -it SheW Array Skirt End Caps are pre -Instafled on the East end ofeach skirt section, and are uses! to couple the skirt secttons where neeried (see Fig, A ), Tighten Mfd-CIamp bolt, damping Rock -it Array Skirt to mount. True to 200 In4lo, 0 30 In-tbs. when Installing with 32 mor rnockees), 3-4 Insta Rock -it Couplings (when joining 4 panels with a Coupling, the use of at load hearing foot Is required) Prior to mounting on the roof, snap Load Bearing Foot Into the bottom of Reek -It Coupling If required. Each Load Bearing Foot Isset to same height as the Rock -it Mounts - adjust accordingly) On eave row only, slide Rock -it Array Skirt onto Rock -it Coupling Shelf. Torque to specified valise. NOTE: If a coupling lands on a rafter, the Hybrid Mount* should be used in place of the Rock It Coupling (refer to image 3a)r Hybrid Mount can be made In the field by assembling a coupling to a mount pedestal, or by purchasing separately. 5 Align and Straighten First Row of the Rock -It System with Rock -it Array SkirtUseNonh-South adjustment ofthe Rock -it Peckutial to straighten Rock -it Array Skirt and allgn module with Array Skirt Torque screw on side of Rock -et Pedestal to 150 InAbsto secure It to the Rock -it Sticie. Adjust Flange Level Nut to level the system (optional - can be levelleril during or a1wInstaUticrn). 6- 9 Install I st Row of RV Modules Slide upstope R&k4t Mounts down to engage top of first module, Install Rock -it Couplingson the upslope side of I st row of panels. Torque 2nd rowof mid-Clamisson Rock-ft Mounts and Rock -it Couplings to specified value. Install balance of PV modules, ensuring that the Rock -It pedestals are in the appropriate position, then torque Mid -Camps to securemodule,,- 10 Level the Rock -It System When assembly Is complete, level the entire system by adjusting Flange LeM Nuts (Rave Level Nuts have no torque value). Height between roof surface and underside of modules should be 3'or less, when installed with Type 2 module& INSTALLATION NOTE: Modules should be installed so that the junction box is installed upslope, away from the leading edge of the array. www, ecofastensolar.com itifo@ecofastensolar.com 877-859-3947 GrounDnG LLAGinSTaLL Necessary Components: One of the following ground lugs (or any UL 2703 compliant ground lug): Burndy CL50-1TN Ground Lug (UL 2703 - E351343 / UL 467 - E9999) ILO SGB-4 Ground Lug (UL 2703 - E354420 / UL 467 - E34440) ILSCO GBL-4DBT (UL 2703 - E354420 / UL 467 - E34440) IL CO GBL-4DBTH (UL 2703 - E354420 / UL 467 - E34440) IUSCO GBL-4SS (UL 2703 - E354420 / UL 467 - E34440) Note: Drill and deburr hole in Ground Lug prior to installation 14 AWG - 4 AWG Copper Ground Wire* TorqueValues: B- 32 x 0.5" Serrated Flange Head Bolt (300 Series SS) 14-10 AWG20 in-lbs. 8-32 Serrated Flange Nut (300 Series SS) 8 AWG= 25 in-lbs, 11 /32' and 1/4" wrenches or ratchets/sockets 6-4 AWG= 35 in-lbs. Insert the flange bolt into the module ground hole. Place Star Washer over bolt, Place ground lug over the bolt and Star Washer, and turn to desired orientation. 2 Install Flange Nut, 3 Tighten Flange Nut/Bolt, 4 Place wire in Ground Lug channel and tighten setscrew to complete assembly, Wire should be sized in accordance with the National Electrical Code, NFPA 70, Section 690.45, and a minimum of 1/4" clearance required between bare copper wire and aluminum, Drill hole per grounding lug manufacturers specifications in the upslope part of Rock -it Coupling for attaching grounding lug. IMMEMMMMUMrMEMMMME= www. ecofastensolar.com info@ecofastensolar.com 877-859-3947 6 ROCK -IT CLIP SS inSTaLL I Locate all parts you will be mounting the micro-inverter/power oltimizer, See fig, A for acceptable mounting locations, 4 Ak MO* M0410YJ LMALIM Install the Rock -it Clip SS Slide the Rock -it Clip SS onto the lip ofthe module frame. Slide the micro-inverter/power optimizer Into the opposite lip of the Rock -it Clip S& Tighten the bolt to 150 in -lb minumum to clamp the Rock -it Clip SS to the module frame and the micro -Inverter/ ower optimizer to the Rock -it Clip SS. Ensure that the rp on the clip is tight against the frame and that the micro-inverter/power optimizer flange tight against the clip flange to avoid rotation during tightening. ROCK -IT CLIP 2.OinSTaLL 1 Locate all parts Locate the Rock -it Clip 2.0, micro-inverter/power optimizer, and the section of the module frame in which you will be mounting the micro-inverter/power optimizer, Install the Rock -it Clip 2.0 (See below detail) Slide the Rock -it Clip 2.0 onto the lip of the micro-inverter/power optimizer. Slide the micro-inverter/power optimizer into the opposite lip of the module frame. Tighten the bolt to 150 In -lb to clamp the Rock -It Clip 2.0 to the module frame and the micro-inverter/power optimizer to the Rock -it Clip 2A Ensure that the lip on the clip is tight against the frame and that the micro-inverter/power optimizer flange Is tight against the clip flange to avoid rotation during tightening. www.ecofastensolancom info@ecofastensolar.com 877-859-3947 MIN= Spacing Governed by Snow Load 1 I Valms howevor the designer must round down'to most appropriate rafter spacing 2.) Maximum allowed spacing approved by EoDFasten Solar is 72" 3.) Maximum alla"d standoff capdty = 547# (per testing results) 4.) Includes additional factor of safety of 1 .5 for lag pullout capacity 5.) Values based on a maximum module width of 4D" 6) Based on Risk Category 11 (ASCE 7-10) structures lose than 30 feet In height 7.) AD adjustment factors, are set to 1 No site specific engineering Is inctuded In this tal Snow Load 0-20 psf nwas: 111111M Spacing Governed by Snow Load 14 '1411W- OZff 2.) Maximum allowed spacing approved by EcoFasten Solar is 48" 3.) Maximum allowed standoff capcity - 547# (per testing results) 4.) Includes additional factor of safety of 1.5 for WO pullout capacity 5.) Values based on a maximum module length of 70' 6.) Based on Risk Category 11 (ASCE 7-10) structures less than 30 feet In height 7.) Ali adjustment factors are set to I No site specific engineering is included in this table www.ecofastensolar.corn info@ecafastensolar.com 877-859-3947 Snow Load 21-30 psf however the designer must round down to meet appropriate rafter spacing 2.) Maximum allowed spacing approved by EcoFasten Solar is 72" 3) Maximum allowed standoff capoity - 547# (per testing results) 4.) Includes additional factor of safety of 1 .5 for lag pullout capacity 5,) Values based on a maximum module width of 40' 6.) Based on Risk Category 11 (ASCE 7-10) structures less than 30 feet In height T) All adjustment factors are set to 1 No site specific engineering Is Included In this table no Load 21-30 psf V140tes: WMIMSpacing Governed by Snow Load 1,) Values in above table represent the maximum allowable spacing In Inches for pullout forms only on Ecol'asten Solar standoff 2.) Maximorn allowed spacing approved by EcoFasten Solar Is 48" 3.) Maximum allowed standoff pcity = 547# (per testing results) 4.) Includes additionel factor of safety of 1,5 for lag pullout capacity 5.) Values based on a maximurn module length of 70" 6.) Based on Risk Category II (ASCE 7-10) structures less Man 30 toot in height T) All adjustment factors are set to 1. No site specific engineering Is included in this table www.ecofastensolar.com i nfo@ecofa stensolar,com 877-859-3947 Snow Load 31-40 psf 0111OW spacing Governed by snow Load 1,) Values in above table represent the maximum allowable spacing in inches for pullout forces only on EcoFasten Solar standoff, however the designer must round down to meet appropriate rafter spacing 2,) Maximum allowed spacing approved by EcoFasten Solar is 72" 3.) Maximum allowed standoff calicity = 547# (per testing results) 4.) Includes additional factor of safety of 1.5 for lag pullout capacity 5.) Values based on a maximum module width of 40" 6.) Based on Risk Catogoiy 11 (ASCE 7-10) structures less then 30 feet in height T) All adjustment factors are set to 1. No site specific engineering is included in this table n® Load 31-40 psf Notes: MMM Spacing Governed by Snow Load 1,) Values in above table represent the maximum allowable spacing In inches for pullout forces only on EcoFasten Solar standoff 2,) Maximum allowed spacing approved by EmFasten Solar is 48" 3) Maxinrury allowed standoff capc4 = 547# (per testing results) 4.) Includes additional factor of safety of 1,5 for lag pullout capacity 5.) Values based on a maximum module length of 70" 6.) used on Risk Category It (ASCE 7-10) structures less than 30 feet in height 7,) All adjustment factors are set to 1. No site specific engineering 15 included in this table www,ecofastensolar.com infolpecolfastensolarcorn 877-859-3947 10 Rates: NIMM Spacing,d by Snow Load ver . designerround down pullout2.) Maximum allowed spacing approved by Ecol'asten Solar Is 72" 3.) Maximum allowed standoff capcity - 547# (per testing results) 4.) Includes additional factor of safety of I 5 for lag p 5.) Values based on a maximum module width of 40" 6.) Based on Risk Category 11 (ASCE T-10) structures less Man 30 fast in height t 'S •: Snow Load 41-50 psf Notes: Spacing Governed by Snow Lead 1.) Values in above table represent ft maximum allowable spacing In Inches for pullout forces only on E Fasten Solar standoff 2.) Maximum allowed spacing approved by EcoFasten Solar Is 48" 3.) Maximum allowed standoff capcity = 547# (per testing results) 4.) Includes additional factor of safety of 1.5 for lag pullout capacity 5.) Values based on a maximum module length of 70" fi.) Based on Risk Category it (ASCE 7-10) structures less than 30 feet in height 7.) All adjustment factors are set to 1. No site specific engineering Is Included In this table www.ecofastensolar.com. Snow Load 51-60 psf Notes: 11NIM Spacing Governed by snow Load 1,) Values in above table represent the maximum allowable spacing In inches for pullout forces only on EcoFasten Soler standoff, however the designer must round down to meet appropriate rafter spacing 2.) Maximufn allowed spacing approved by EcoFasten Solar Is 72' 3,) Maximum allowed standoff capcity = 547# (per testing results) 4,) Includes additional factor of safety of 1.5 for lag pullout capacity 5,) Values based on a maximum module width of 40' 6.) Based on Risk Category 11 (ASCE 7-10) structures less than 30 feet in height 7.) All adjustment factors are -,at to 1. No site specific engineering Is Included In this table Snow Load 51-60 psf Notes-, N= Spacing Governed by Snow Load 1,) Values in above table represent the maximum allowable spacing in inches for pullout forces only on EcoFasten Solar standoff 2,) Maximum allowed spacing approved by EcoFasten Solar is 48' 3.) Maximum allowed standoff capcity - 547# (per testing results) 4.) Includes additional factor of safety of 1.5 for lag pullout capacity 5,) Values based on a maximum module length of 70' 6.) used on Risk Category 11 (ASCE 7-10) structures less than 30 feet in height T) All adjustment factors are set to 1, No site specific engineering is included in this table www.ecofastensolar.com info@ecofastensolar.com 877-859-3947 12 GrounDnG nFOrmaTion The rail -free Rock -it System may be used to mount and ground PV modules that comply with UL 1703, only when that specific module has been evaluated for mounting and grounding, in compliance with the Included Installation instructions, Note: Grounding lug must be visible to Inspectors from the entire perimeter ofthe PV array. Multiple Use Grounding Pins Grounding pins within the Mid -Clamp are multiple use bondk*grounding devices, Modules will need to be adjusted if the Mid -Clamps are loosened to ensure there is "new"metalto pierce into upon retightening, Grounding Method Rock -It 4.0 Mount bonds N-S rows of modules Rock -it 4.0 Coupling bonds E-W rows of modules Rock -It Array Skirt bonds E-W along the entire array when Installed One Burndy CL50-1TN ground lug is required per PV array, limited to 300 modules placed in either portrait or landscape orientation. BonDrG ASseMBLY anD BonDinGpaTH Do"d P.?" G'r'1110WR WE 10, R`W rtw" nmh R"k It 'Aoum R 6 11 Amly SWI B 0 [loth G"A4.&,x Wx EquPmal" Qmvn,1'%' Fri it o"""wirg R-J" t" A. fay "'kv www.ecofastensolar.com info@ecofastensolar.com 877-859-3947 13 SYSTem SPeClFicaTlons MaxNo, of Panels 300 Modules per ground lug Materials 300 Series Stainless, WN Series Aluminum Maas System Voliage 1000VDC Coating Black Andoclization/Mill Finish Class A Fire Rating with UL1703Type 1 Rated Lug Specifications Rurndy C1250-1TIN Ground Lug Modules, see note below. UL Listing #KDER 9) Leveling Range 3-4" Ground Wire 14 AWG- 4 AWG Copper Per above Lug spec, Ground Wre Rock -it Slide Comp Range 3" Max Module Size 64.96"(1650 ) x Rock -It Slide Tile 7" 39D5"(992 rn) x 2'(5 m) Min/Max Roof Slope 1/2:12i12:12 _.._.._., Max Downforce/Uplift Rating 45 PSF Max Anchor Spacing (39€»m ) 72* Rock -it Mount Load Rating 5471Lss with Single 5J16" Lag 3.0 Max Anchor Spacing (32mur) 0. Safety Factor Skirt Box UTY 6 units Slide Fastening Hole 5/16' c iarnecer Mount Box 12 units Module Cantilever Maximum cantilever is 1t3 Rock -It Slide Box QTY 50 units bracket spacing Coupling Box QTY 12 units warranty 20Year Material and Workman- ship C National Electric Code, AN15VNFPA 70, NEC 250, NEC 69D, IRC, IBC Standards; UL 2703: First Edition, UL 1703 CUfi'6S:RREb Yt UL tiM ga9 firtGE a'h. aatdC The EcoFasten SolarRock-It System is a rooftop PV racking system consisting of 6M Series Aluminum and 300 Series Stainless Steel components. The Rock -it System Includes the rack components but does not Include the PV panels, Inverters or electrical components. The PV modules to be used withRock-It shall be certified under UL 1703. The system shall be used on steep slope roofs mounted over a Class A fire rated roofing material and attached to the roof structure using 5/16" diameter, minimum 4' long 300 series Stainless Steel lag bolts with minimum thread embedment depth of 21 /2" into the roof structure. Periodic re -inspection for loose components The system is subject to re -Inspection as required by the PV module manufacturer or by the Authority Having Jurisdiction. Re -inspection, as required, should include evaluation of any loose components or loose fasteners. All loose components and fasteners should be secured In accordance with these instructions. The system should also be evaluated for any evidence of corrosion.. Any corrosion should be removed. Any affected part should be cleaned or replaced in accordance with these instructions, FcoFasten Solar www.ecofastensolar.com info@ecofastensolar.com 77- 59-39 7 15 FeaTures New and improved design . North -South adjustability Fastest, easiest to level system on the market - Only one tool required (1 /2'deep wells ketj Integrated electrical bonding . Vertical adjustment of 3'-4' SIMPLE- only 4 components EvaWaTeDi, compaTIBLeMODULes Hanwha 0- Cells 32mm modules to be useed with spedal order Rock -It System component1j, Call for details, yAv W.- 4 sfAn www.ecofastensolar.com lnfo@ecofastensolar.com 877-859-3947 -K, 1. Installation to be completed in accordance with manufacturer's wdtien specifications and Installation instructions. 2. See spec sheet or contact manufacturer for detailed material, finishes, and configuration options. 3, Contact manufacturer for detailed layout. 4. Do not scale dravvin S. 5. Subject to change Vithout notice. U-1 11 7in L [80.54mm 2.50in 63.50mm i 2.02in 2.14in 234 51,38r,nm 'I 1-54a7rrumi 159.36n 32mm 35mm ASI LYPINE 414, UARDS, Ecol;wten Solar GToll Free Phone 1,888,766.4273 Toll Free Phone 1 ,877,8,59,3947 Toll Free Fax 1 .88&7W9994 Toll Free Fax 1,888,766,9994 EISIM 4741 W Polk Street Ste, 4 Phoenix, AZ 85043 Material: See Spec Sheet Scale: 1:2 6/2812017 ,SSG; - EFS: X Data Sheet Enphase Networking Enphase The Drliphase AC Combiner Box- with Enphase Envoy,-S' consolidates interconnection equipment intoACombinerBoxasingleenclosureandstreamlinesPVinstallationsby providing a consistent, pre -wired solution for residential applications. 0 LISTED To learn More about Enphase offerings, visit enphase.com M= Includes Envoy-S for communication and control Flexible networking supports W141, Ethernet, or cellular Three pre -installed 20 A 1240 VAC circuit breakers Pre -configured revenue -grade metering available Reliable Durable NUL-certified NEMA type 3R enclosure Five-year warranty ENPHASE XAM1-120-9 (880-00834) or AC Combiner with Enphase Envoy-S Metered- for integrated revenue grade PV production XAMl-120 (880-00211) metering (ANSI G1220 +/- 0.5%) and optional consumption monitoring (+/- 2.5%). ACCESSORIES (order separately) Enphase Mobile Connect- Plug and play industrial grade cellular modem with five-year data plan for systems up to 60CELLMODEM-01 (3G) or microinverters, (Available in the US, Canada, Mexico, Puerto Rico, and the US Virgin Islands, CELLMODEM-03 (4G) where there Is adequate cellular service in the Installation area.) Consumption Monitoring CT Split core current transformers enable whole home consumption metering (+/- 2.5%). CT-200-SPLIT ELECTRICAL SPECIFICATIONS Rating Solar branchcircuit breakers Maximum system voltage Rated output current Rated Input current, each input Maximum fuse/circuit breaker rating (output) Continuous duty Three 2-pole 20 A 1240 VAC DIN rail -mounted breakers 240 VAC 48A 16 A 60A ProducWn Metering CT 200 A solid core pre -installed on solar busbar and wired to Envoy-S I Dimensions (WxHxD) 38.0 x 38.7 x 20.3 cm (15.0"x 15.3'x 8.0') Weight 51 kg (112 lbs) Ambient temperature range 40° C to +460 C (-401 to 1150 F) Cooling Vented, natural convection, plus heat shield Enclosure environmental rating Outdoor, INIRTL-certified, NEIVIA type 3R, polycarbonate construction Altitude To 2000 meters (6,560 feet) Wire size: Follow local code requirements for conductor sizing. Mode[XAMI-120-6 14 to 6 AWG copper conductors for branch inputs. 14 to 4 AWG copper conductors for combined output. ModeIXAM1-120 12 to 6 AWG copper conductors for branch Inputs, 12 to 4 AWG copper conductors for combined output. ATEAMET COo,'VAECTIOA OPTIONS Integrated Wi-Fi 802.11b/g/n Ethernet 802.3, Cat5E (or Cal 6) UTP Ethernet cable - (not included) Cellular Optional, CELLMODEM-01 (3G) or CELLMODEM-03 (4G) - (not included) COMPLIANCE Compliance, Combiner Box UL 1741 Compliance, Envoy-S UL 916 CAN/CSA C22.2 No, 61010 1 47 CFR, Part 15, Class 8, ICES 003 IEC/EN 61010.1:2010, EN50065-1, EN61000-4-5, EN61000-6-1, EN61000-6-2 Metering: ANSI C12.20 accuracy class 0.5 To learn more about Enphase offerings, visit enphase.com ENPHASE GaugeBasic Featurais Stamped Seamless Construction Galvanized Steel Flashes into * Powder Coated Surfaces Roof deck knockouts Centering dim. entryi fittings or conduft 2 Position Ground lug Installed Mounting Hardware Included Models - Model Wording to the UL STD 1741 for r VlodelY01 € 4- Din Rail Mounted Fuse Holders 60OVDC 3DAMP ail fastened using Norlock System ModelSDO786-41 6"Slotted Din Rail fastened using steel "s 4- Din Rail Mounted Terminal Blocks Bus Bars with UL lug 4- Din Rail Mounted Fuse Holders 60OVDC 30 AMp im FOrproductinforurafton call 1(866)367-7782 Revision JAN 2 2 2018 Response to Comments Permit # 18-4667 Project Address: 521 Red Rose Ln Sanford FL 32 Contact: Momentum Solar Submittal Date Ph: 321-247-6073 - I ( 3 1 Fax: Email: flpermits@momentumsolar.com / Trades encompassed in revision: Building Plumbing Electrical Mechanical Life Safety Waste Water City of Sanford Building & Fire Prevention Division Ph: 407.688.5150 Fax: 407.688.5152 Email: building@sanfordfl.gov General description of revision: Single line change: add 3 panels to array 2, subtract 1 panel from array 1, subtract 2 from array 4 ROUTING INFORMATION Department Approvals Utilities Waste Water Planning Engineering Fire Prevention Building 6E 2- • (% momentum SOLAR DATE: 8248 Parkline Boulevard, Suite 100 Orlando, FL 32809 Phone: 732.902.6223 I hereby name and appoint AMin "y I U of Momentum Solar to be my lawful attorney -in -fact to act for me, and apply to the Division of Building Safety for a Building/Electrical (PHOTO VOLTAIC SOLAR PANELS) permit ONLY (NOC and Permit Application) for work to be performed at a location described as: Owner of Property: eviV-A av-am6L k a Project Address: 60L t P-ed Vos z C-. i 6ag-Cvr3. , FL and to sign my name and do all things necessary to this appointment - Matthew Franz /, Contractor Name) ('type or Print) ` (Con Signature) EC 13008217 Contractor's License Number) The foregoing instrument was acknowledged before me this day of by ikAn i 1exa-.,, L4 to 7' who is personally known to me or who produced did not take an oa . A-Nnde kr-c=Ckw- Notary Public (Print Name) Notary Public (signature) of 20 as identification and who Seal Otppy Aimee McGurr cP NOTARY PUBLIC j c STATE OF FLORIDA. Comm# GG200147 NCE 19 0 Expires 10/23/2021 PLAN KEY PV-1 COVER PAGE PV-1.1 COVER PAGE CONT. PV-2 PANEL LAYOUT PV-3 LAYOUT DETAIL PV-4 ELECTRICAL PV-4.1 ELECTRICAL COAT, PV-4.2 EQUIPMENT LABELS HANWHA Q.PEAK DUO BLK-G5 315 315 WATT OIl SEE DATASHEET) BILL OF MATERIALS MODULES 25 INVERTERS 25 CLAMP ASSEMBLY 74 COUPLING ASSEMBLY BONDING, CLIP 42 9 SKIRTS 13 ENPHASE COMBINER BOX 1 EATON 60A FUSIBLE AC DISCONNECT 1 40AFUSES 2 35A BACKFEED BREAKER 1 SYSTEM INFORMATION MODULE HANWHA Q.PEAK DUO BLK-GS 315 INVERTER ENPHASE IQ7-60-2-US RACKING ECOFASTEN ROCK -IT SYSTEM SYSTEM SIZE (DC) 7.875 KW LOCATION 28.817166®-81.317885 ROOF SHALLHAVE #•E THAN TWO LAYERS OF COVERINGADDITION QOLAR EQUIPMENT. 11144 x CLIMATIC & GEOGRAPHIC DESIGN CRITERIA TABLE R301.2(1) SPEED (MPH) 140 TOPOGRAPHIC EFFECTS B SPECIAL WIND REGION NO WIND BORNE DEBRIS ZONE 2 SEISMIC DESIGN CATEGORY C CLIMATE ZONE 2A WIND EXPOSURE CATETORY B o WE r TABLE 3 1.2.1. WIND SPEEDSI® a VL lc 110 115 120 130F140 150 160 170 180 190 F2OO V,,d 85 89 93 101 108 116 124 132 139 147 155 For SIo 1 mile per hour = 0,447 m/s. a. Linear interpolation is permitted. momentum SOLAR PRO CUSTOM SOLAR LLC D.B.A. MOMENTUM SOLAR 325 HIGH STREET, METUCHEN, N3 08840 732) 902-6224 MOMENTUMSOLAR.COM 1 No 6142 TA7 ` OF CAMERON CHRISTENSEN CER71€IED SOLAR CONTRACTOR lTCBNSE NUMBER: CVC57036 MOMENTUM SOLAR 5728 MAJOR BLVD. SUITE 307 ORLANDO FL. 32819 CUSTOMER INFORMATIOM 521 RED ROSE LN E SYSTEM SIZE (DC): 7.875 KW 25 MODULES: HANWHA Q.PEAK DUO BLK-G5 315 25 INVERTERS: ENPHASE IQ7-60-2-US PROJECT INPO04ATION INITIAL DATE: 11/30/2018 1 DESIGNER: AC SCALE: 3/32" = V-0" 1 UDC AC CB1IDISCI i ELECTRICAL EQUIPMENT fI 10011, 0 0motM 0 M rn p r- 21U M M NOTE- 1. ROOF COVERING MATERIAL IS COMPOSED OF SINGLE LAYER ASPHALT COMPOSITE SHINGLE, 2. REFER TO LAYOUT DETAIL DRAWING PV-3 FOR ALL ROOFTOP DIMENSIONS. ROOF PANEL COUNT TILT AZIMUTH SHADING Rl 17 26* 179' 99% k - toR2526* 359' 95% momentum R 3 3 26, 89. 99% SOLAR PRO CUSTOM SOLAR LLC D,B.A, MOMENTUM SOLAR 325 HIGH STREET, METUCHEN, N) 08840 732) 902-6224 MOMENTUMSOLAP.COM STRUCTURAL GROUND ACCESS TYR) FIRE SETBACK 36" VENTILATION, 36" ROOF ACCESS) 0 t Z t4 86142 Q 7, --A7E- OF ir-AALS01 z19.4 CAMERON CHRISTENSEN CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER: CVC57036 MOMENTUM SOLAR 5728 MAJOR BLVD, SUITE 307 ORLANDO FL, 32819 INFORMATION VENKATARAMA NAMPALLY SYMBOL LEGEND 521 RED ROSE LN SANFORD, FL 32771 772) 359-3550MSBMAINSERVICEPANELCHIMNEY PV SYSTEM BLK-G5 315 25 INVERTERS: ENPHASE IQ7-60-2-US UDC UTILITY DISCONNECT FAN LCF LOAD CENTER SATELLITE DISH INrrIAL R.3 NEMA 3R BOX W/ ENVOY-S FIRE SETBACKS AS PER 6TH EDITION 2017 FFPC REV: 1 CB COMBINER BOX MIN 3'x3' GROUND ACCESS POINT REV: MODULE PITCH DIRECTION WIND PRESSURE ZONE LINES. REFER TO PV-2,2 FOR ADDITIONAL INFO PP03ECT INIFORMATION DATE: 11/30/2018 DESIGNER: AC DATE: 1/2/2019 DESIGNER: RH DATE: DESIGNER: wzW) R1— ARRAY 1 LAYOUT DETAIL R2 — ARRAY 2 LAYOUT DETAIL SCALE: 1/8" _ 1s_O" SCALE: 1/8" _ 11_OI, momentumTILT: 26' TILT: 26' TM AZIMUTH: 179' AZIMUTH: 359' SOLAR SHADING: 99% SHADING: 95% PRO CUSTOM SOLAR LLC D.B.A. MOMENTUM SOLAR 325 HIGH STREET, METUCHEN, NI 08840 12'-8" (732) 902-6224 Gi MOMENTUMSOLAR.COM STRUCTURAL 3'-0" / i i / 3 -0" ENGINEERING 5 w 3'-0" z ,. C " y 42 i I ( o _• I 17i 0 0'-6" 3'-11'" 21'-0" 1 54'-101E 45°-92, z SOLAR INSTALLER NOTES: SOLAR INSrALLER NOTES - NO ADDITIONAL STRUCTURAL SUPPORT REQUIRED NO ADDITIONAL STRUCTURAL SUPPORT REQUIRED RR3``— ARRAYQQ3 LAYOUT DETAIL SOLAR CONTRACTOR SCALE: 1/t,ikt S 11('I!i CAEN RTIFIE CHL4,RCCONTRACTOR0ddLICENSE SOLAR C VC57036LICENSENU¢BER: CVC57036 TILT. 26 €hMOMENTLPM SOLAR 5728 AfOR SLVD, SUITE 307 AZIMUTH: 89® ORLkNDO FL. 32819 SHADING: 99% CUSTOMER INFORMATION VENKATARAMA NAMPALLY S21 RED ROSE LN SANFORD, FL 32771 772)359-3550 PV SYSTEM INFORMATION3 / \ SYSTEM SIZE (DC): 7.875 KW Y ; 1"-6'f 1f9 € 5 MODULES: HA€1 HA Q.PEAK DUO 15 --6- 25 INVERTERS: ENPHASE IQ7-60-2-US E t \\ \ PROJECT INFaRaaarroN INrrIAL DATE: 11/30/2018 DESIGNERI AC REV: I DATE: 1/2/2019 DESIGNER: RH REV: DATE DESIGNER: 7'-112" LAYOUT DETAIL SOLAR INSTALLER MOTES NO ADDITIONAL STRUCTURAL SUPPORT REQUIRED PV MODULE RATINGS MODULE MAKE HANWHA MODEL Q.PEAK DUO BLK-G5 315 MAX POWER 315W OPEN CIRCUIT VOLTAGE 40.29V MPP VOLTAGE 33.46V SHORT CIRCUIT CURRENT 9.89A MPP CURRENT 9.41A NUMBER OF MODULES 25 UL1703 COMPLIANT YES INVERTER RATINGS VOLTAGE DROP CALCULATIONS INVERTER MAKE ENPHASE FORMULA USED PER NEC 2014 HANDBOOK 215.2(A)(4) WHERE APPLICABLE MODEL IQ7-60-2-US WIRE RUN V"P I'P R. L (FT) VO % VO WIRE SIZE MAX OUTPUT POWER 240W BRANCH TO J-BOX 240.00 13 1.98 85.58 4.406 1.84% 12 AWG OPEN DC VOLTAGE 48V 3-BOX TO LOAD NOMINAL AC VOLTAGE 240V CENTER 240.00 MAX AC CURRENT 1A LOAD CENTER TO AC 240,00DISCONNECT CEC INVERTER EFFICIENCY 97% AC DISCONNECT TO INTERCONNECTION 240.00 NUMBER OF INVERTERS 25 UL1703 COMPLIANT YES OF MODULES PV BREAKER THIS SOLAR PHOTOVOLTAIC SYSTEM COMPLIES WITH THE 2017SUBPANELPERBRANCH BREAKER SIZE FLORIDA BUILDING CODE AND THE 2014 NATIONAL ELECTRICAL CODE UP TO 16 20A 25 1.24 50.00 3.100 1.29% 10 AWG 31.25 0.778 3.00 0.146 0.06% 08 AWG 31.25 1 0.778 10.00 0.486 0.20% US RATING €. x< x 1,21 .. MAIN BREAKER BACI , D AVAILABLE EXISTING 200A SUB UTILITY PANEL 240 V METER GRID g momentum SOLAR PRO CUSTOM SOLAR LLC D.B.A. MOMENTUM SOLAR 325 HIGH STREET, METUCHEN, NJ 08840 732) 902-6224 MOMENTUM SOLAR. COM ENPR, SE 80A I AC MBINER SOLAR CIRCUIT SOLAR CONTRACTOR BOX DISCONNECTING MEANS € / CAMERbR4 CNRFSfEKSEM Z00A CERTIFIED SOLAR CONTRACTOR e a I LICENSE NUMBER: CVCS 636 EATON 60A FUSIBLE AC`' MOMENTUM SOLAR t ^ j 5728 MAJOR BLVD. SUITE 307 BOX DISCONNECTING MEANS 0 DISCONNECT ' ORLANDO FL. 32819 8 ; g 200A CUSTOMER 40A 35AINFORMATIONIt SC3LADECK 10A F2EAKERMH-._ VENKATARAMA NAMPALLY POWER 521 RED ROSE LN JUNCTION (NVOY) I 40A FUSES AGROUND SANFORD, FL 32771 I BOX 2A' B 20A BI AKER (A) 3 3 EXISTING 200A (772j 359-3550TERMINATIONCAP20ABRAKER (B) INSTALLED ON METER MAIN PV SYSTEM END OF CABLE 200A BREAKER INFORMATION SYSTEM SIZE (DC): 7.875 KWJ25MODULES: HANWHA Q.PEAK DUO 25 INVERTERS: ENPHASE IQ7-60-2-US Wire Tag Conduit Wire Qty Wire Wire Type Temp. Wire Temp. Conduit Dented Inverter NOC (A) NEC Design Ground Ground Wire Gauge Rating Ampacity (A) Derate Fill Derate Arnpaclty (A) City Correction Current (A) Size Type PRO3ECT INFORMATION 1 OPEN AIR 2 12 AWG Trunk Cable 901E 30 0.96 1 28.80 13 1 1.25 16.25 12 AWG Trunk Cable INITIAL DATE: 11/30/2018 DESIGNER: AC REV: 1 DATE: 1/2/2019 DESIGNER: RH 2A 1" PVC 2 10 AWG THWN-2 901E 40 0.96 0.8 30.72 12 1 1.25 1S.00 08 AWG THWN-2 REV: DATE: DESIGNER: 2B 1° PVC 2 10 AWG THWN-2 901E 40 0.96 0.8 30,72 13 1 1.25 16.25 08 AWG THN-2 - 3 1ti PVC 3 08 AWG THWN-2 756C 50 0.96 1 48.00 25 1 1.25 31,25 08 AWG THWN-2 1. ALL CALCULATIONS FOR VOC, VMAX, IMP AND ISC HAVE BEEN CALCULATED USING THE MANUFACTURED D EXTREME ENTIRE2, THE ARRAY paragraph THE GROUND IS CARRIED FROM THE GROUNDING LUG USING #6 BARE COPPER WIRE. 3. THIS SYSTEM COMPLIES WITH NEC 2014 4. BRANCH DISPLAYS LARGEST WILL HAVE LOWER DESIGN CURRENT THAN THE ONE SHOWN, IN ADDITION, VOLTAGE DROP CALCULATIONS FROM PANELS TO THE COMBINER BOX WILL BE SHOWN IN A SIMILARFASHION BASED5. ALL CONDUCTORS ARE SIZED RATED6. ALL EQUIPMENT INSTALLED IS REQUIREMENTS7. INVERTER NOC (NOMINAL OPEN CURRENT) OBTAINED FROM EQUIPMENT DATASHEET 8. CONTRACTOR RESPONSIBLE FOR COMPLYING WILL ALL LOCAL OR NATIONAL CODE AND 1 INSTRUCTIONS 9EACH MODULE MUST BE GROUNDED ACCORDING TO SUNMODULE USER INSTRUCTIONS 10. ALL P; *. sNEC 690,17, PROVIDE A WARNING SIGN LOCATIONS TERMINALS SHALLOPEN POSITION> SIGN 1ELECTRIC HAZARD PERMANENTDO NOTTOUCHTERMINALS - OR EQUIVALENT, R. PREMISESSHOWING ALLELECTRICPOWERSOURCESONTHE13. INTERCONNECTION METHOD SHALL COMPLY WITH NEC 69064 14AND OPTION FOR A SINGLE CIRCUIT BRANCH BRANCHES• • 15. ALL R 16. NEUTRAL ' EQUIPMENT GROUNDING CONDUCTOR BONDED AS PER R ELECTRODE s 18. FUSES + r PV DISCONNECT HAVE AIC RATINGS OF 200KA AC AND 20KA DC 19. SUPPLY SIDE CONNECTION SHALL BE INTERCONNECTIONPIERCING CONNECTORS ( IPC). MAKE, MODEL, AND RATING OF x BE SEEN ON TABLE 1 BELOW WORKING20. METHOD OF INTERCONNECTION CAN BE SEEN IN FIGURE 1. 21. UTILITY HAS 24-HR UNRESTRICTED ACCESS TO ALL PHOTOVOLTAIC SYSTEM COMPONENTS LOCATED AT THE SERVICE ENTRANCE. 22. x * x AROUND ELECTRICAL EQUIPMENT WILL B MAINTAINED ARTICLEARTICLE 110, 26. 23. CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS SUNLIGHT RESISTANT PER NEC TOTAL24, CONDUCTORS EXPOSED TO WET LOCATIONS SHALL BE SUITABLE FOR USE IN WET LOCATIONS PER NEC ARTICLE 310.8 (C). 25. AREA OF ALL CONDUCTORS, SPLICES, AND i INSTALLED AT CROSS SECTION OF THE WIRING DOES NOT EXCEED 75% OF THE SECTIONALCROSS x OFTHESPACE. f, SYSTEM IS CONSIDERED CONDUCTORS ARE PRESENT IN CONDUIT, COMBINER, JUNCTION BOX, AND COMPLIES 690.6 - NO DO DISCONNECT AND ASSOCIATED DO LABELINGx • REQUIRED. RAPID27. SYSTEM COMPLIESWITH690.12 AND ASSOCIATED LABELING AS i56(C), AC VOLTAGE AND SYSTEM OPERATING CURRENT SHALL BE PROVIDED 690,52, 28, CONDUCTORS IN CONDUIT ARE AC CONDUCTORS AND NOT PV SOURCE CIRCUITS. 690.6. 29ALL ... a MODULES) IN THAT THE AC ENERGIZED30, NO TERMINALS WILLBE ; MODULE APPLICABLE:31. WHERE MAKEMODELVOLTAGE CONDUCTOR CONDUCTOR RATING RANGE MAIN RANGE TAP ILSCO IPC 4020 600 V 4/0-4 AWG 6-14 AWG ILSCO IPC 4006 600 V 4/0-2 AWG 2/0-6 AWG F;VfrT suitableI. Adjustthe connector2.Put the branch wire nut to #cepsheath fully 3.1naert the main wire.[( there are two toy* of Insulated toy In the main coblos,should strip a certain length a of the firstlayfrom4.Turn the nut by hond.ond 5. crew the nut with the sleeve $.Screw the nut Continually until the fix the connector In suitable spanner. top part is tracked and dropped down. location momentum PRO CUSTOM SOLAR LLC D.B.A. MOMENTUM SOLAR 325 HIGH STREET, METUCHEN, NJ 08840 732) 902-6224 MOMENTUMSOLAR.COM 51W1 i •741ffi. w.J CAMERON CHRIST€NSEN CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER: CVCS7036 MOMENTUM SOLAR 5728 MAJOR BLVD. SUITE 307 ORLANDO EL, 32819 1 " 01112 0 521 D ROSE WA ®- ' INVERTERS:25 3 x INITIALDATE: 11/30/ 2018 DESIGNER: AC REV: 1 DATE: 1/ 2/2019 DESIGNER: RH 6 REV: 1 DATE: ( DESIGNER: E