801 Park Ave - BR18-004562 - REROOF2 1 CITY OF SANFORD NOV I qBUILDING & FIRE PREVENTION tPERMIT APPLICATION Application No: L45 (.0 2. Documented Construction Value: $ 1. & cl Job Address: Vie,9 2 7 -7/ Historic District: Yes E No ParcelID: - tr - s v ,', to C,, 3 - 06 6 ca Residential B Commercial Type of Work: New Addition Alteration Repair Demo Change of Use Move Description of Work: i2 r,rxfr,a_z. i 5 4,-f r r , Plan Review Contact Person: Title: rrz . Phone: L,, I r Fax: 4z4e,7- 2 3 4r7 Property Owner Information Name 6 N. - rt . L-U L'1W - Phone: Ott- 7 - y t Street: re, I /?oaIc- Resident of property? ; Ze.5 City, State Zip:—5-111,.,vrzrn Contractor Information Name L' rr /j,1: rl rl sxs ff.rt 1! e 1V4,z:c4 Phom Street: c' G3G 0 i rif-4; s r7%17G Fax: City, State Zip: _i 1rz ,. x b / > State J Architect/ Eng 1neer InformationName: Phone': Street: Fax: City, St, Zip: E-mail: Bonding Company: Address: etc'•- Z03 7f 1-- Mortgage Lender: Address: j lY ; 3 - y -7 7 2--. No.: _el ee' r 3 2 is 3 FK WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners~ etc. FBC 105. 3 Shall be inscribed with the date of application and the code in effect as of that date: 5 h Edition (2014) Florida Building Code Revised: June 30, 2015 Permit Application NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may befoundinthepublicrecordsofthiscounty, and there may be additional permits requiredfrom other governmental entities such as water managementdistricts, state agencies, or federal agencies. Acceptance of permitis verification that I will notify the owner of theproperty of therequirements of Florida Lien Law, FS 713. The City of Sanfordrequires payment of aplan review fee at the time of permitsubmittal. A copy of theexecuted contract is required inordertocalculateaplanreviewchargeandwillbeconsideredtheestimatedconstructionvalueofthejobatthetimeofsubmittal. TheactualconstructionvaluewillbefiguredbasedonthecurrentICCValuationTablieineffectatthetimethepermitisissued, in accordancewithlocalordinance. Should calculated charges figured off the executed: Contract exceed the actual construction value, creditwillbeappliedtoyourpermitfeeswhenthepermitisissued. OWNER' S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will bedoneincompliancewithallapplicablelawsregulatingconstructionandzoning. turc of OwncrlAgent Date signature o t for/Agent Date Print Oa r/Agents Name Print Contratitor/Ageint's Name gn re o otary- S COMM.. jr OF E 2 I go/ _ * TENNESSEE O'% NOTARY Owner/ Agent is personally pORLIC Knowp, tlettr.,•..••J` ProducedIDTypeofID '%may OF 8"- \\` 11i110", ln5n licStateofJIMilliamssionGG00827616/2020 Contractor/Agent is —y— Personally Known to Me or Produced ID " Type of ID AELOW IS FOR OFFICE USE ONLY Permits Required: Building Electrical Mechanical[] Plumbing Gas[] Roof [] Construction Type: Occupancy Use: Flood Zone: _ Total Sq Ft of Btdg: Min. Occupancy Load: # of Stories: New Construction: Electric - # of Amps Plumbing'= # of Fixtures Fire Sprinkler Permit: Yes [] No [ APPROVALS: ZONING: ENGINEERING: COMMENTS: i of Heads Fire Alarm Permit: YesEl UTILITIES: WASTE WATER,: FIRE: BUILDING: Revised: June 30, 2015 Permit Application No [J Grant erk Of The cuit Court nt #20181y31139 Book:9251rPage 3778( Comptroller RCDn11/192018t9 0:53 AM REC FEE $10.00 THIS INSTRUMENT PREPARED BY: ItName: Over the Too Roofers, LLCAddress: NOTICE OF COMMENCEMENT Permit Number: CE D CO GRANT MALOY C Rif 0i, ++T COURT - i ,, t-L "RiO s BY - DUUTY CLERK Date PareelIDNumber _2V-/1- The undersigned hereby gives notice that improvement will be made to certain real followingInformationisprovidedinthisNoticeofCommencemenLproperty, and hl accordance with Chapter 713. Florida Statutes, the 1. DESCRIPTION OF PROPERTY: (Legal description of thepropertyand street address If avaliabl) L.crT G r AJ .. (, ---r aP- -7 2. GENERAL DESCRIPTION OF IMPROVEMENT: 3. OWNER INFORMATION OR LESSEE INFORMATION IF THE LESSEE CONTRACTED FOR' " IIHE IMPROVEMENT: Nameandeddress:l.e- i 41—rcL,q Interest In property: 04vn/AefL Ig4,7(9/1 •• S— ^.l' cx- Fee Simple Title Holder (if otherthan owner listed above) Name: ^-- Address 4. CONTRACTOR: Name: _Greg9 Boyich Phone Number 407.293.4715 Address: 5036 Dr. Phillips Blvd, Ste 296, Orlando FL 32819 S. SURETY (H applicable, a copyof the payment bond is attached): Name: Address.• 6. LENDER -'Name: Address: Phone Persona within the State of Florida Designated by Owner upon whom notice or other doi 713.13(1)(a)7., Florida Statutes. Name: 11 Phone In addition, Owner designates -_ to receive a copy of the Lienoes Notice as provided in Section 713.13(t)(b). Florida Statutes. Expiratlon Date of Notice of Commencement (The expiration Is 1 year from date of recording Amount ofBond: may be served as provided by Section number: a different date is specified) WARNING TO OWNER ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION! OF THE NOTICE OF COMMENCEMENT ARE CONSIDEREDIMPROPERPAYMENTSUNDERCHAPTER713, PART 1, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYINGTWICEFORIMPROVEMENTSTOYOURPROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOBSITEBEFORETHEFIRSTINSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORECOMMENCINGWORKORRECORDINGYOURNOTICEOFCOMMENCEMENT. State of QAA 914 f leCounty of The foregoing Instrument was acknowledged before me this day of cu is by Who i personally known to me OR Nam 60paltymakingamemeMwhohas produced IdentiticationA type of identification produced: r <` LL 0 Z%SL Q/.? 6 2 30 1. 0rrrl 3118nd 'moo y ALIVI O N _74P ry sw mwre 33SS3NN3-L C.T"rnISso-» zxP 31d S = / e 1 t OVER THE TOP ROOFERS, LL OVER THE TOP 5036 Dr. Phillips Blvd. R40FERS.,.: Suite 296 CCC 1328358 Orlando, FL 32819 Phone: 407-2934715 Fax: 407-293-4722 WWW Bill To: Joh Loving 1330 Nobel Street Alcoa, 'I'N. 37701 phone not provided email not provided Contract Date Estimate # 10/2/2018 15106 Job: . Chris;I_oving / S011 801 gouth Park Ave Sanford. Fl. 32 71 407-116-5036 chrisloving03 r mail.com ectWeherebysubmitspecificationsand/or estimates for: j P.O. No. ProjDying801 Item . l Description Ot Rate I Total Plain Roof * We will tarp all planters, walkways and drivn%uys. 17.337.00 17,337.00 Tear off and remove existing shingle roof on house. inspect roofdecking and re -nail entire deck even, 6 in. as per FI. Code. Furnish & install GAF Tiger Pa%v undedayment. Remove & replace all existing valley metal, drip edge (color to be picked). vet t pipes, roof vents and dryer vents. (Paint exposed PVC.). We will use a starter shingle at first rmv of caves. We will install new shingles with 6 ea. nails per shingle per Fl. Code. Furnish and install a GAF Timberline j0 yr. 1.130 mph) ,,architectural Shingle. Color to be picked by home owner). All gutters . ifany. will be cleaned out at completion ofjob. Clean & dispose of all rooting debris from property & use a magnet around th house. First 2 sheets of damaged decking will be replaced at no charge.:\nthing the • after will be an additional $85.00 a sheet installed = Ist 4 leaks free! Any fascia or planked roof decking replaced will be an additional $9.00 It. (Ccdar $10.00 It) Ifany siding needs replaced $95.00 a sheet & $9.00 it tar siding trim installed. Ifany flashing or tongue & groove is needed. Additional S7.75 ft. Iftruck cannot deliver to rooftop. Additional S400.00 If dumpster cannot be set by roof. Additional 5400.00 Ifthere is a Direct TV antenna on roof wwe will remove but are not responsible br rc-installing. EotireContractor will provide all necessary permits. Seven year workmanship guarantee project will take approximately 4 or 5 days. start to finish. To do same as above on separate structure, Additional $2437.00 To install 56 it of GAF Cobra 3 shingle over ridge vents. Additional S473.00 i To install squirrel proof covers on all lead boots. Additional S32.00 each To perform a wind mitigation. Additional $125.00 Ifyou are interested in the above just initial on lines) and we will add it to toi al on invoice. After final payment is made and cleared the bank. we will issue a final waiver to ien. Re -roof- 100 % duc DAY OF COMPLETION. Repair- duc upon commencement. I Oq`0 of the total will be assessed after 30 days. An)- collections fees will he the customers Totalresponsibility. If using a credit card a convenience fee of 3.0 % is added. Not responsible for any damages to concrete from delivery vehicles. We do not cover pooling water. If' existing fascia or soffit n)VaVall during theme ob j iynot our rWonsibluy nor are gutters. Date: /® a 17.337.00 LIMITED POWER OF ATTORNEY Altamonte Springs, Casselberry, Lake Mary, ]Longwood, Sanford, Seminole County, Winter Springs Dater -6l 1-6 I hereby name and appoint: an agent of: 1(, c ' -_, o. r- r- Name of Company) m _ attorney -in -fact to a e to apply for, receipt fo sign for and do all things necessary to this appointment for (check mj one option): The specific permit and application for work located at: o l 5c.-• - i arz is v r Street Address) Expiration Date for This Limited Power of Attorney: License Holder Name: G-0C.CGIlc)v) CH State License Number: CCC 13Z 35 s Signature of License Holder: C—) STATE OF FLORIDA COUNTY OF 6_ The foregoing instrument was acknowledged before me this day ol`%;4 20 a by g who is personally known tomeorowhohasproducedas identificationandwhodid (did not) take an oath. Signature Notary Seal) Print or type name r o0Notary Public state of Florida Notary Public - State of `ELO «p a4HelenMWilliamsEx Commission 20 008278 Commission No. Expires08/1612020 `- My Commission Expires: Rev. 08.12) 4 CERTIFICATE OF APPROPRIATENESS HISTORIC PRESERVATION BOARD CITY OF SANFORD 300 S. Park Avenue Sanford, Florida 32771 407.688.5145 • www.sanfordfl.gov/HP THIS DOCUMENT MUST BE POSTED AT ALL TIMES UNTIL PROJECT IS COMPLETED. ISSUED TO: Over The Top Roofers for 801 Park Avenue Sanford, FL 32771 BP#19-143 DATE ISSUED: November 19, 2018 DATE EXPIRES: May 20, 201 Approved to re -roof with architectural shingles (Timberline High Definition Birchwood) and underlayment as needed. Limited repair/replacement of damaged/deteriorated wood may be performed as part of the re -roof. Repair/replacement must be wood, must match the existing original in dimension, profile, texture, and all other visual qualities. Repair/replacement areas must be keyed in so repair/replacement is not visible when work is complete. All pitched roof surfaces, including but not limited to porches and additions must have matching architectural shingles. Eileen Hinson, Development Services Manager Please be advised it is the owner and/or agent's responsibility to notify staff of any potential changes from the approved COA that arise and obtain approval prior to commencing the changes. This Certificate of Appropriateness does not constitute final development approval. The applicant is responsible for obtaining all necessary permits and approvals from applicable departments before initiating development. IS A BUILDING PERMIT REQUIRED FOR THE ACTIVITY LISTED ABOVE? YES NO Building Department Representative r'61!59' y) nlrST:'rla . • APPLICATION # H FOR A CERTIFICATE OF APPOPRIATENESS Answer all the questions on this form and submit all required attachments. Incomplete applications will not be reviewed. If you have questions about application requirements contact the Historic Preservation Officer at 407.688.5145 to ensure your application is complete. General Information Downtown Commercial Historic District[] Residential Historic District V Is this a retroactive request? Yes No Is this application filed in response to a Notice of Violation from the Code Enforcement Department? Yes[] No Proposed improvements will affect the following elevations: North South East West Property Address: '60 1 v'!o A' t-i ?A1 ia 1 -- A V Property Owner Information Print Name: Mailing Address: 1330..rlt 1 Phone: ti() 'I- Email: '"— Signature: Applicant/Agent Information Print Name: -. ` i h - tU 1ir . t- s" . c, ; L i • :;,. t Mailing Address: C Z.1.D OA I cl Phone: o "'` "Ll 1 IS- Email: -DA, Q du+=yi t-U+ Rr VG d T--I (I rbt,+ Signature: TI BY SIGNING BELOW YOU ACKNOWLEDGE THAT A BUILDING PERMIT MAY BE REQ_UJRrD FOR TFIE SCOPE OF WORK LISTED BELOW. YOU MUST CONTACT THE BUILDING DEPARTMENT TO DETERMINE IF A BUILDING PERMIT IS REQUIRED. FAILURE TO OBTAIN A BUILDING PERMIT WILL RESULT IN A STOP WORK ORDER, DOUBLE PERMIT FEES, AND POTENTIAL FINES. BY SIGNING BELOW, YOU ALSO ACKNOWLEDGE THAT THE INFORMATION CONTAINED IN THIS APPLICATION IS TRUE AND ACCURATE TO THE BEST OF YOUR KNOWLEDGE. I hereby understand and agree t9ba above statements and will pay all city fees related to this application as required by the cjt s a . o d-olution. Would you liketd/receive emails regarding Historic Preservation and Community Planning within your community? Description of proposed work Completely describe the entire scope of work, including changes in material and color, and methods that will be used to accomplish the proposed work. For large projects an itemized list is required. Use the reverse side if necessary. C) HISTORIC PRESERVATION BOARD • 300 N. Park Avenue • Sanford, Florida 32771 •407.688.5145 • www.sanfordfl.gov/HP MM- t- OVER TI•IE I'OP ROOFERS. CCC 1328358 OVER THE TOP ROOFERS, LLC 5036 Dr. Phillips Blvd. Suite 296 Orlando, FL 32819 Phone: 407-2934715 Fax: .407-293-4722 Rill To: Jolt Loving 1330 Nobel Street Alcoa,'I'N. 37701 phone not provided email not provided Contract Date Estimate # 10/2/2018 1i 106 Job: . Chrisjl_oving / on 801 South Park Ave Sanford. 1:1. 32 71 407416-5036 chrisloving03ya gmail.com 2Weherebysubmitspecificationsand/or estimates for: \ P.O. No. ProjectLovingSUI Item . I Description Ot Rate Total Plain Roof * We will tarp all planters, walkways and drive%%ays• 17.337.00 17,337.00 Tear off and remove existing shingle roof on house. inspect roof decking and re -nail entire deck ever• 6 in. as per FI. Code. Furnish & install GAF Tiger Paw undcrlayment. Remove & replace all existing valley metal, drip edge (color to he picked). ver, t pipes, roof vents and dryer vents. (Paint exposed PVC). W'e will use a starter shingle at first row of caves. We will install new shingles with 6 ca. nails per shingle per FI. Code. Furnish and install a GAF Timberline 50 yr. (130 mph) Architectural Shingle. Color to be picked by home owner). All gutters . if any, will be cleaned out at completion of job. Clean & dispose ofa11 roofing debris from property & use a magnet around thd house. First 2 sheets ofdamaged decking will be replaced at no charge. AnIthing the • alter will be an additional $85.00 a sheet installed = I st 4 leaks 1•rce! - Any, fascia or planked roofdecking replaced will be an additional S9.00 It. (Ccdar S 10.00 ft) Ifany siding needs replaced $95.00 a sheet & S9.00 !t tur siding trim installed. Ifany flashing or tongue & groove is needed. Additional S7.75 ft. Iftruck cannot deliver to rooftop. Additional S400.00 If dumpster cannot be set by roof. Additional S400.00 Ifthere is a Direct TV antenna on roof*%ve %rill renwve but are not responsible ur re -installing. Contractor %%ill provide all necessary permits. Seven year workmanship guarantee. Entire project will take approximately 4 or 5 days. stun to finish. To do same as above on separate structure. Additional S2437.00 To install 56 ft ofGAF Cobra 3 shingle over ridge vents. additional S473.00 To install squirrel proof covers on all lead boots. Additional S32.00 each To perform a wind mitigation. Additional S 125.00 Ifyou are interested in the above just initial on line(s) and we %will add it to to al on invoice. After final payment is made and cleared the bank. we will issue a final ngiver to iien. Re -roof -100 % due DAY OF COMPLETION. Repair - due upon commencement. 10% of the total will be assessed after 30 days. Any collections fees will be the customers Totalresponsibility. If using a credit card a convenience fee of3.0 % is added. Not responsible for any damages to concrete from delivery vehicles. We do not cover pooling water. If existing fascia or soffit I all during the job i i not our re onsiblay nor arc gutters. Signature. Date: aJ 17.337.00 r ter IV Wav J F •, s fey •• f_t _• y - it •- - K 1 , a w 1•r x YID J5 w. i Wa * . i. .' • fv Mwe earl.-t.'.L . . _ __. .._ _ t.Lw3 •3 r , • , J- - - i - f J r• • 1 i. ` -{' , " r jM, + ; -•'-+'?•-'.. tom . r, i eAJ e : [ a fi { 4 •` Nj4 1F R 1tI i• ' .`y'; v - - ' _. . its +• A. ` ..E ww. rf rfE Pam!. i`"r,z ` s • ' a i '` f ` v 4 ,s• 14t,.!tr 9 Z`yi.x'c ro yi r ` t '_ F ' Ire i' "i. rt S ;r?Y .e _ s'!,- .^y.;•tom+ a. q , y' r iTXWto1rti s 3`g i t ` 3 0 :vx N i • ` c r+'yu. , ,,,i r 7 eJ r!4d hc£• .. ,V r. yi .. :. 4 - 4 :t, t- Ik T I• e°.s~ ,`rl'i 7M Ir. r' a C`.• - Kn+a;-.'4 , _ ,r b } r t. rt• Fr c tc w r. i s .N e .iLa • , e. L J')` _.. it . +'! ed:.i: iv trZa.1 N A ' + '• . a3 D • S PERMIT # g' Lo 2 1 City of Sanford Building Division Residential Re -Roof Scope of Work JOB ADDRESS: 00/ STRUCTURE TYPE: E5 SINGLE FAMILY RESIDENCE/TOWNHOUSE O MOBILE RE -ROOF TYPE: 01EPLACEMENT (TEAR OFF EXISTING ROOF AND REPLACE WITH? O RE-COVER (NEW ROOF INSTALLED OVER EXISTING ROOF) DECK TYPE (PLEASE SPECIFY): }i [ /L eta../` /_ , G PLEASE NOTE: ONL Y IOO SQUARE FEET OF THE EXISTING DECK IS PERMITTED TO BI ROOF VENTILATION: D OFF -RIDGE RIDGE O SOFFIT OPOWE SKYLIGHTS: O YES O IF YES, PLEASE PROVIDE FLORIDA PRODUCT APPRO MAIN ROOF AREA ROOF SLOPE: O LESS THAN 2:12 TYPE OF ROOF SHINGLE METAL MODIFIED BITUMEN TORCH DOWN INSULATED TILE OTHER: Q 2:12 — 4:12 4: 12 OR GREA MANUFACTURER G/kF.+i3Li242.E AN ROOF EXTENSIONS (PORCHES PATIOS ETC) ""IFAPPLICABLE"" ROOF SLOPE: O LESS THAN 2:12 2:12 — 4:12 O 4:12 OR GREA' TYPE RooF SHINGLE METAL MODIFIED BITUMEN TORCH DOWN INSULATED Z) TILE D OTHER: TOME O APARTMENT/CONDOMINIUM EW COMPONENTS) REPLACED" ED VENT OTURBINES AL #: FLORIDA PRODUCT APPROVAL FL# 1012 y - /2Zo FL# FL# FL# FL# FL# FL# MANUFACTURER FLORIDA PRODUCT APPROVAL FL# FL# FL# FL# FL# FL# FL# City of Sanford Building Division Re -Roof Inspection Policy & Procedures PERMITTING REQUIREMENTS — NO PLAN REV EW REQUIRED This document (signed) along with an accurate and completed Residential Re -Roof Scope of Work are required to be submitted as part of your permit application. The Scope of Work must include all applicable Florida Product Applov l numbers for all roof components that will be installed on the project. A permit will not be issued without these documents. Copies will be Projects located in the Sanford Historic District will require plan Historic Preservation Board INSPECTION POLICY & A Final Roof Inspection is the only inspection required for Residential Home, Apartment and/or Condominium) Re -Roof Permits. The Following is required to be provide on the job site: • Permit Card, posted in a conspicuous and weatherproof location Completed Residential Re -Roof Scope of Work Completed and Notarized Inspection Affidavit All Florida Product Approval and Corresponding Installation Product Approval shall match what is on the scope of work) to post on the job site. iew and approval by the Sanford Single Family, Townhouse, Mobile 11 Digital Photographs (must include the permit number or address in each picture) o Each plane of the roof, showing the underlayment installed o Roof Deck Nailing Pattern & Spacing (including a measuring device or ruler) o Roof Deck Nails used (including a measuring device or r o Underlayment Pattern & Spacing (including a measuring o Drip Edge & Valley Attachment (including a measuring 4 o Shingles installed, nail pattern and location of nails Skylights (if applicable) o Digital photographs showing all installation components, p o Digital photographs showing all required flashing, per FL I showing size of nails) ice or ruler) or ruler) FL Product Approval Approval Failure to follow these specific guidelines will result in an affidavit rovided by a Florida Design Professional (architect or engineer), certifying FBC code compliant by personal inspection. e CONTRACTOR (OR OWNERIBUILDER) SIGNATURE: C DATE: 1 1 _ _ PLC • - BCIS Home Log In User Registration Hot Topics I Submit Surcharge Stats & Facts Publications Contact Us I BCIS Site Map I Links Search FlOnda AOF&a _ Product Approval USER: Public Userr v Product Approval Menu > Product or Agolication Search > ggolication List > Application Detail t FL # FL10626-R14 Application Type Revision Code Version 2017 Application Status Approved Comments Archived Product Manufacturer GAF Address/Phone/Email 1 Campus Drive Parisppany, NJ 07054 800)766-3411 mstieh@gaf.com Authorized Signature Robert Nieminen lindar@nemoetc.com Technical Representative William Broussard Address/Phone/Email 1 Campus Drive Parsippany, NJ 07054 800)766-3411 TechnicalQuestionsGAF@gaf.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Underlayments Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Robert Nieminen Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 06/16/2019 Validated By John W. Knezevich, PE Certificate of Independence Referenced Standard and Year (of Standard) Validation Checklist - Hardcopy Received FL10626 R14 COI 2018 01 COI NIEMINEN.pdf Standard Year ASTM D1970 2015 ASTM D226 (physicals) 2009 ASTM D4533 (tear) 2015 ASTM D6164 2011 ASTM D6757 2016 FM 4474 2011 FRSA/TRI April 2012 (04-12) 2012 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 06/05/2018 Date Validated 06/16/2018 Date Pending FBC Approval 06/26/2018 Date Approved 08/15/2018 Summary of Products FL # Model, Number or Name Description 10626.1 GAF Roof Underlayments Roofing Underlayments for use in sloped roof systems Limits of Use Installation Instructions Approved for use in HVHZ: No FL10626 R14 II 2018 06 FINAL ER GAF UNDERLAYMENTS FL10626- R14.pfifApprovedforuseoutsideHVHZ: Yes Impact Resistant: N/A Verified By: Robert Niemien 59166 Design Pressure: +N/A/-442.5 Created by Independent Third Party: Yes Other: 1.) The design pressure noted in this Evaluation Reports application relates to one particular underlayment FL10626 R14 AE 2018 06 FINAL ER GAF UNDERLAYMENTS FL10626- R14.p ifsystemforuseunderfoam -on tile systems. Refer to ER Section 5.6.4 for details. 2.) Refer to ER Section 5 Created by Independent Third Party: Yes for other Limits of Use. Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Ltatement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: ached M Credit Card Sate NEW I etc. Certificate of Authorization #32455 353 Christian Street, Unit #13toOxford, CT 06478 203) 262-9245 ENGINEER EVALUATE TEST CONSULT CERTIFY GAF Evaluation Report 01506.04.08-1114 1Campus Drive FL10626-1114 Parsippany, NJ 07054 Date of Issuance: 04/25/2008 800) 766-3411 Revision 14: 06/06/2018 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of Construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 6" Edition (2017) Florida Building Code sections noted herein. DESCRIPTION: GAF Roof Underlayments LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the product(s), the Quality Assurance or the production facility location(s). NEMO I etc. requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "NEMO I etc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 11. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCA ANE1983 The facsimile seal appearing yppearinwasauthorizedb Robert cS;' •- "%:- g' Nieminen, P.E. on 06/05/2018. This does not serve as an N. electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. NEMO ETC, LLC does not have, nor does it intend to acquire, or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither NEMOletc. nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. ONEMO I etc. ROOFING COMPONENT EVALUATION: Product Category: Roofing Sub -Category: Underlayment Compliance Statement: GAF Roof Underlayments, as produced by GAF, have demonstrated compliance with the following sections of the Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. Section Property Standard Year 1504.3.1 Wind Uplift FM 4474 2011 1507.1.1, R905.1.1 Exception Unrolling, Breaking Strength, ASTM D226 2009 Pliability 1507.1.1, R905.1.1 Exception Tear Strength ASTM D4533 2015 1507.2.3 / 1507.1.1 Physical Properties ASTM D6757 2016 1507.2.4 / 1507.1.1, 1507.2.9.2 Physical Properties ASTM D1970 2015 1507.3.3 Physical properties FRSA/TRI April 2012 (04-12) 2012 1507.11.2 Physical Properties ASTM D6164 2011 Entity Examination Reference Date ERD (TST 6049) Physical Properties R3360.02.07-2-R1 03/13/2007 ERD (TST 6049) Physical Properties G12110.12.08 12/02/2008 ERD (TST 6049) FRSA/TRI April 2012 (Slippage) G34150.08.11 11/14/2011 ERD (TST 6049) ASTM D6164 G40630.01.14-2B 01/07/2014 ERD (TST 6049) ASTM D6164 G46160.09.14-3A 09/09/2014 ERD (TST 6049) ASTM D1970 GAF-SC13285.03.17-3 03/01/2017 ERD (TST 6049) ASTM D1970 GAF-SC13285.03.17-4 03/01/2017 PRI (TST 5878) Physical properties BRY-003-02-01 03/19/2002 PRI (TST 5878) ASTM D1970 GAF-026-02-01 03/26/2002 PRI (TST 5878) ASTM D1970 GAF-027-02-01 03/26/2002 PRI (TST 5878) Physical properties GAF-042-02-01 06/03/2005 PRI (TST 5878) Physical properties GAF-224-02-01 07/27/2009 PRI (TST 5878) ASTM D1970 GAF-238-02-01 03/03/2010 PRI (TST 5878) ASTM D1970 GAF-275-02-01 11/11/2010 PRI (TST 5878) Physical properties GAF-349-02-01 07/03/2012 PRI (TST 5878) Wind Uplift GAF-434-02-01 09/16/2013 PRI (TST 5878) Wind Uplift GAF-434-02-03 09/16/2013 PRI (TST 5878) Wind Uplift GAF-434-02-04 09/16/2013 PRI (TST 5878) FBC 1507.1.1 (Exception) GAF-818-02-01 12/05/2017 PRI (TST 5878) FBC 1507.1.1 (Exception) GAF-826-02-01 06/04/2018 PRI (TST 5878) FBC 1507.1.1 (Exception) GAF-847-02-01 06/04/2018 UL (TST 1740) Physical properties 02NK22569 06/04/2002 UL (TST 1740) ASTM D6757 1ONK11990 05/18/2011 Miami -Dade (CER 1592) HVHZ compliance 16-1216.02 02/02/2017 Miami -Dade (CER 1S92) HVHZ compliance 18-0119.15 02/22/2018 ICC-ES (EVL2396) IBC/IRC compliance ESR-2053 07/01/2017 ICC-ES (EVL2396) IBC/IRC compliance ESR-2808 07/01/2017 ICC-ES (EVL2396) IBC/IRC compliance ESR-1322 01/01/2018 ICC-ES (EVL2396) IBC/IRC compliance ESR-3286 02/01/2018 UL, LLC (QUA 9625) Quality Control Inspect, File R10689 (BC) 06/27/2017 UL, LLC (QUA 9625) Quality Control Inspect, File R10689 (CA) 07/07/2017 UL, LLC. (QUA 9625) Quality Control Inspect, File R10689 (GA) 02/02/2018 UL, LLC. (QUA 9625) Quality Control Inspect, File R10689 (IN) 01/10/2018 NEMO ETC, LLC Evaluation Report 01506.04.08-1114 Certificate afAathorization #32455 6'" EDITION (2017) FBC NON-HVHZ EVALUATION F1.10626-1114 GAF Roof Underlayments; (800) 766-3411 Revision 14: 06/05/2018 Page 2 of 11 ONEMO I etc. Entity Examination Reference Date UL, LLC. (QUA 9625) Quality Control Inspect, File R10689 (NC) 03/14/2018 UL, LLC (QUA 9625) Quality Control Inspect, File R10689 (OK) 06/20/2017 UL, LLC (QUA 9625) Quality Control Inspect, File R10689 (ON, QC) 05/18/2018 UL, LLC (QUA 9625) Quality Control Inspect, File R10689 (SC) 06/16/2017 UL, LLC (QUA 9625) Quality Control Inspect, File R10689 (TX) 05/24/2016 UL, LLC (QUA 9625) Quality Control Inspect, File R10689 (INDIA) 04/13/2018 UL, LLC (QUA 9625) Quality Control Inspect, File R10689 (LA) 04/23/2018 4.1 Self -Adhering Underlayments: 4.1.1 Liberty'"' SBS Self -Adhering Base/Ply Sheet is a smooth -surfaced, fiberglass -reinforced, self -adhering SBS modified bitumen roof underlayment; meets ASTM D1970. 4.1.2 StormGuard® Film Surfaced Leak Barrier is a film -surfaced, fiberglass -reinforced, self -adhering SBS modified bitumen roof underlayment; meets ASTM D1970. StormGuard® Film Surfaced Leak Barrier is also used as a secondary water barrier to seal roof decks. 4.1.3 WeatherWatch® Mineral Surfaced Leak Barrier is a mineral -surfaced, fiberglass -reinforced, self -adhering SBS modified bitumen roof underlayment; meets ASTM D1970. WeatherWatch® Mineral Surfaced Leak Barrier is also used as a secondary water barrier to seal roof decks. 4.2 Mechanically Fastened Underlayments: 4.2.1 VersaShield® Fire -Resistant Roof Deck Protection is a non -asphaltic, fiberglass -based roof underlayment and/or fire barrier; meets physical requirements of ASTM D6757. 4.2.2 Deck -Armor'"" Premium Breathable Roof Deck Protection is a non -woven, spun -bonded polypropylene laminated polyethylene scrim sheet roof underlayment, available in 48-inch or 54-inch roll widths; meets FBC 1507.1.1 & R905.1.1 (Exception). 4.2.3 RoofPrOTM SBS-Modified All -Purpose Underlayment is a fiberglass -reinforced, SBS modified bitumen roof underlayment; meets AC165. 4.2.4 Shingle -Mate® Roof Deck Protection is a fiberglass reinforced, asphaltic roof underlayment; meets FBC 1507.1.1 & R905.1.1 (Exception). 4.2.5 StormSafeTm Anchor Sheet is a polypropylene woven fabric which serves as an anchor sheet in two-ply roof underlayment systems; meets FBC 1507.1.1 & R905.1.1 (Exception). 4.2.6 Tiger Paw'm Roof Deck Protection is a non -woven, polypropylene reinforced, polymer coated roof underlayment; meets FBC 1507.1.1 & R905.1.1 (Exception). 4.3 Asphalt -Applied Underlayments: 4.3.1 Ruberoid® Mop Granule is a granule -surfaced, polyester -reinforced, asphalt -applied SIBS modified bitumen roof underlayment; meets ASTM D6164. 4.3.2 Ruberoid® Mop Granule FR is a granule -surfaced, polyester -reinforced, asphalt -applied SBS modified bitumen roof underlayment; meets ASTM D6164. NEW ETC, LLC Evaluation Report 01506.04.08-R14 Certificate afAuthorization #32455 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL10626-R14 GAF Roof Underlayments; (800) 766-3411 Revision 14: 06/05/2018 Page 3 of 11 ONEMO I etc. 5.1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. 5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory or test report from accredited testing agency for fire ratings of this product. 5.4 GAF Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering. 5.5 Allowable Roof Covers: ROOF COVEROPTIONS Wood Slate or Underlayment Asphalt Nail -On Tile Foam -On Metal Shakes & Simulated Shingles Tile Shingles Slate Deck -Armor"' Premium Breathable Contact Contact Contact Yes No NoRoofDeckProtection GAF GAF GAF RoofProT" SBS-Modified All -Purpose Yes No No No Yes Yes Underlayment Shingle -Mate® Roof Deck Protection Yes No No No No No Contact Contact Contact Tiger Paw`" Roof Deck Protection Yes No No GAF GAF GAF VersaShield® Fire -Resistant Roof Deck Yes No No No No No Protection Liberty"' SBS Self -Adhering Base/Ply Yes No No No No No Sheet StormGuard® Film Surfaced Leak Yes No No Yes No No Barrier WeatherWatch® Mineral Surfaced Yes No No No No No Leak Barrier Yes Ruberoid® Mop Granule Yes Yes No Yes Yes See 5.5.1 Yes Ruberoid® Mop Granule FR Yes Yes No Yes Yes See 5.5.1 5.5.1 "Foam -On Tile" is limited to use of the following Approved tile adhesives / underlayment combinations. 1 Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance. NEMO ETC, LLC Evaluation Report 01506.04.08-1114 Certificate ofAuthorization #32455 6T" EDITION (2017) FBC NON-HVHZ EVALUATION F1.30626-1114 GAF Roof Underlayments; (800) 766-3411 Revision 14: 06/05/2018 Page 4 of 11 OMEMO I etc. 5.6 Allowable Substrates: 5.6.1 Direct -Bond to Deck: Liberty'"" SBS Self -Adhering Base/Ply Sheet; StormGuard® Film Surfaced Leak Barrier and Weather Watch® Mineral Surfaced Leak Barrier self -adhered to new untreated plywood or existing untreated ASTM D41 primed plywood. Ruberoid® Mop Granule and Ruberoid® Mop Granule FR in hot asphalt to ASTM D41 primed structural concrete. 5.6.2 Bond to Mechanically Attached Base Laver: Liberty'"" SBS Self -Adhering Base/Ply Sheet; StormGuard® Film Surfaced Leak Barrier and WeatherWatche Mineral Surfaced Leak Barrier self -adhered to ASTM D226, Type II felt Ruberoid® Mop Granule and Ruberoid® Mop Granule FR in hot asphalt to GAFGLAS' #80 UltimaT" Base Sheet or Ruberoid® 20 Smooth. 5.6.3 Bond to Other Substrate Types: ASTM D41 primed metal (flashing metal, valley metal, etc.) 5.6.4 Wind Resistance for Underlayment Systems in Foam -On Tile Applications: FRSA/TRI April 2012 (04-12) does not address wind uplift resistance of all underlayment systems beneath foam - on or mortar -set tile systems, where the underlayment forms part of the load -path. The following wind uplift limitations apply to underlayment systems that are not addressed in FRSA/TRI April 2012 (04-12) and are used in foam -on or mortar -set tile applications. Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FRSA/TRI April 2012 (04-12), Appendix A, Table 1A or FBC 1609 for determination of design wind loads. 1 Maximum Design Pressure = -45 psf. Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Layer: GAFGLAS® #80 UltimaTm Base Sheet or Ruberoid® 20 Smooth mechanically attached with 12 ga., min. 1.25-inch long ring shank nails through 32 ga., 1-5/8-inch diameter tin caps spaced 9-inch o.c. at the 4-inch wide side laps and 9-inch o.c. at two (2), equally spaced, staggered center in the field of the sheet. Top Layer: Ruberoid° Mop Granule or Ruberoid® Mop Granule FR applied in full mopping of ASTM D312, Type IV hot asphalt at 20 to 25 Ibs/square. 2 Maximum Design Pressure = -75 psf. Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Layer: GAFGLAS® #80 UltimaT"" Base Sheet or Ruberoid® 20 Smooth mechanically attached with 12 ga., min. 1.25-inch long ring shank nails through 32 ga., 1-5/8-inch diameter tin caps spaced 8-inch o.c. at the 4-inch wide side laps and 8-inch o.c. at three (3), equally spaced, staggered center in the field of the sheet. Top Layer: Ruberoid® Mop Granule or Ruberoid® Mop Granule FR applied in full mopping of ASTM D312, Type IV hot asphalt at 20 to 25 Ibs/square. 3 Maximum Design Pressure = -442.5 psf. Deck: Min. 2,500 psi structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction Base Layer: GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Ply 4, Tri-Ply Ply 4 or GAFGLAS Flex Ply 6 applied in full mopping of ASTM D312, Type IV hot asphalt at 20 to 25 Ibs/square. Top Layer: Ruberoid® Mop Granule or Ruberoid® Mop Granule FR applied in full mopping of ASTM D312, Type IV hot asphalt at 20 to 25 Ibs/square. NEMO ETC, LLC Evaluation Report 01506.04.08-1114 Certificate ofAuthorization #32455 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL10626-R14 GAF Roof Underlayments; (800) 766-3411 Revision 14: 06/05/2018 Page 5 of 11 ONEMOletc. 5.6.4.1 For mechanically attached Base Sheet, the maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI April 2012 (04-12), Appendix A, Table 1A. Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC 1609. In this case, Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29 and Roofing Application Standard RAS 117. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January 2016) for Zone 2/3 enhancements. 5.7 Exposure Limitations: 5.7.1 Deck -Armor TM Premium Breathable Roof Deck Protection; RoofProT`" SBS-Modified All -Purpose Underlayment; Shingle -Mate® Roof Deck Protection; StormSafeT"" Anchor Sheet and Tiger PawTm Roof Deck Protection shall not be left exposed for longer than 30-days after installation. 5.7.2 VersaShield® Fire -Resistant Roof Deck Protection, Ruberoid® Mop Granule and Ruberoid® Mop Granule FR shall not be left exposed for longer than 180-days after installation. 5.7.3 Libertyrm SBS Self -Adhering Base/Ply Sheet; StormGuard® Film Surfaced Leak Barrier and WeatherWatch® Mineral Surfaced Leak Barrier shall not be left exposed for longer than 30-days after installation. 5.8 Tile Slippage Limitations (TAS 103 per FRSA/TRI April 2012 (04-12)): When loading roof tiles on the underlayment in direct -deck tile assemblies, the maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles. VrTABLE2: Tit o e s Underlayment Tile Profile Staging Method Maximum Slope Ruberoid® Mop Granule Flat Max. 10-tile stack 4:12 Flat Max. 6-tile stack (4 over 2) 5:12 Lugged Max. 10-tile stack 5:12 Ruberoid® Mop Granule FIRFlat or Lugged Max. &tile stack (4 over 2) 5:12 Lugged Max. 10-tile stack 4:12 6.1 GAF Roof Underlayments shall be installed in accordance with GAF published installation instructions subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application and prime the substrate (if applicable). 6.3 Install self -adhering underlayments when ambient temperatures are minimum 45°F and rising. 6.4 All metal surfaces shall be primed with MatrixTm 307 Premium Asphalt Primer or alternate GAF accepted ASTM D41 primer prior to application of self -adhering membranes. 6.5 Deck -Armor TM Premium Breathable Roof Deck Protection: 6.5.1 Shall be installed in compliance with the requirements for ASTM D226, Type I or II underlayment in FBC Table 1507.1.1 or R905.1.1 for the type of prepared roof covering to be installed, considering the wider sheet -width for double -layer applications. 6.5.2 Minimum fasteners shall be 1-inch diameter plastic -capped corrosion resistant nails or 1-inch diameter plastic - capped, corrosion resistant staples. Code Reference: The Exception statement in FBC 1507.1.1 and FBC R905.1.1 requires use of metal cap nails where the ultimate design wind speed, Vuir, equals or exceeds 150 mph. NEMO ETC, LLC Evaluation Report 01506.04.08-R14 Certificate ojAuthorization #32455 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL10626-R14 GAF Roof Underlayments; (800) 766-3411 Revision 14: 06/05/2018 Page 6 of 11 OMEMO I etc. 6.5.3 Optional, or if required by the Authority Having Jurisdiction: Install a leak barrier of Liberty'' SBS Self -Adhering Base/Ply Sheet; StormGuard® Film Surfaced Leak Barrier; UnderRoof'" 2 Polyester -Surfaced Leak Barrier or WeatherWatch® Mineral Surfaced Leak Barrier at vulnerable leak areas, including but not limited to eaves, valleys, rakes, skylights and dormers. At eaves and valleys, install the leak barrier prior to installation of the underlayment. Along the rake, install the underlayment, leaving 6 to 8-inch of the deck exposed, and then install the leak barrier over the underlayment and exposed decking. At other areas, install the leak barrier over the underlayment. 6.5.4 Non -Tile Roof Installations: Single Layer; Roof Slope > 4:12: Starting at the eave, fasten the eave edge and 6-inch wide end -laps 6-inch o.c. Fasten in the field of the roll 12- inch o.c. in two, equally spaced, staggered center rows. Continue upslope in a similar manner, maintaining minimum 3-inch side -laps and minimum 6-inch end -laps. Fasten 6-inch o.c. in the laps and 12-inch o.c. in two, equally spaced, staggered center rows in the field. Ensure all end laps are staggered at least 3-feet apart. Double Layer; 2:12 < Roof Slope < 4:12: If leak barrier (6.3.3) is not used, install a half -width sheet at the eave prior to subsequent courses. Starting at the eave, fasten the eave edge and 6-inch wide end -laps 6-inch o.c. Fasten in the field of the roll 12-inch o.c. in two, equally spaced, staggered center rows. Continue upslope in a similar manner, with minimum 25.5-inch side -laps for 48-inch wide rolls (resulting in maximum 22.5-inch exposure) or minimum 28.5-inch side -laps for 54-inch wide rolls (resulting in maximum 25.5- inch exposure) and minimum 6-inch end -laps. Fasten 6-inch o.c. along the low edge and end laps and 12-inch o.c. in two, equally spaced, staggered center rows in the field. Ensure all end laps are staggered at least 3-feet apart. 6.6 Tiger Paw'"" Roof Deck Protection: 6.6.1 Shall be installed in compliance with the requirements for ASTM D226, Type I or II underlayment in FBC Table 1507.1.1 or R905.1.1 for the type of prepared roof covering to be installed, considering the wider sheet -width for double -layer applications. 6.6.2 Minimum fasteners shall be 1-inch diameter plastic -capped corrosion resistant nails or 1-inch diameter plastic - capped, corrosion resistant staples. Code Reference: The Exception statement in FBC 1507.1.1 and FBC R905.1.1 requires use of metal cap nails where the ultimate design wind speed, Vuit, equals or exceeds 150 mph. 6.6.3 Optional, or if required by the Authority Having Jurisdiction: Install a leak barrier of Liberty'"' SBS Self -Adhering Base/Ply Sheet; StormGuard® Film Surfaced Leak Barrier; UnderRoof'"' 2 Polyester -Surfaced Leak Barrier or WeatherWatch® Mineral Surfaced Leak Barrier at vulnerable leak areas, including but not limited to eaves, valleys, rakes, skylights and dormers. At eaves and valleys, install the leak barrier prior to installation of the underlayment. Along the rake, install the underlayment, leaving 6 to 8-inch of the deck exposed, and then install the leak barrier over the underlayment and exposed decking. At other areas, install the leak barrier over the underlayment. 6.6.4 Non -Tile Roof Installations: Single Layer; Roof Slope > 4:12: Starting at the eave, fasten the eave edge and 6-inch wide end -laps 6-inch o.c. Fasten in the field of the roll 12- inch o.c. in two, equally spaced, staggered center rows. Continue upslope in a similar manner, maintaining minimum 3-inch side -laps and minimum 6-inch end -laps. Fasten 6-inch o.c. in the laps and 12-inch o.c. in two, equally spaced, staggered center rows in the field. Ensure all end laps are staggered at least 3-feet apart. NEMO ETC, LLC Evaluation Report 01S06.04.08-R14 Certificate ofAuthorization #32455 6'" EDITION (2017) FBC NON-HVHZ EVALUATION FL10626-R14 GAF Roof Underlayments; (800) 766-3411 Revision 14: 06/OS/2018 Page 7 of 11 ONEMO I etc. Double Layer; 2:12 < Roof Slope < 4:12: If leak barrier (6.4.3) is not used, install a half -width sheet at the eave prior to subsequent courses. Starting at the eave, fasten the eave edge and 6-inch wide end -laps 6-inch o.c. Fasten in the field of the roll 12-inch o.c. in two, equally spaced, staggered center rows. Continue upslope in a similar manner, with minimum 25.5-inch side -laps (resulting in maximum 22.5-inch exposure) and minimum 6-inch end -laps. Fasten 6-inch o.c. along the low edge and end laps and 12-inch o.c. in two, equally spaced, staggered center rows in the field. Ensure all end laps are staggered at least 3-feet apart. 6.7 StormSafeTm Anchor Sheet: 6.7.1 StormSafeT" Anchor Sheet is limited to use as a mechanically attached base layer in 2-ply underlayment systems. 6.7.2 Minimum fasteners shall be 1-inch diameter plastic- or steel -capped corrosion resistant nails; corrosion -resistant nails & 1-5/8-inch tin -caps; or Drill-Tec screws and plates. Code Reference: The Exception statement in FBC 1507.1.1 and FBC R905.1.1 requires use of metal cap nails where the ultimate design wind speed, V it, equals or exceeds 150 mph. 6.7.3 Non -Tile Roof Installations: Starting at the eave, fasten the eave edge and 6-inch wide end -laps 6-inch o.c. Fasten in the field of the roll 12- inch o.c. in two, equally spaced, staggered center rows. Continue upslope in a similar manner, maintaining minimum 3-inch side -laps and minimum 6-inch end -laps. Fasten 6-inch o.c. in the laps and 12-inch o.c. in two, equally spaced, staggered center rows in the field. Ensure all end laps are staggered at least 3-feet apart. One the same day, install LibertyTM SBS Self -Adhering Base/Ply; StormGuard® Film Surfaced Leak Barrier or WeatherWatch® Mineral Surfaced Leak Barrier over the StormSafeTm Anchor Sheet. 6.8 RoofProlm SBS-Modified All -Purpose Underlayment and Shingle -Mate® Roof Deck Protection: 6.8.1 Shall be installed in compliance with the requirements for ASTM D226, Type I or II underlayment in FBC Table 1507.1.1 or R905.1.1 for the type of prepared roof covering to be installed. No hammer tacks or staples are permitted. Code Reference: The Exception statement in FBC 1507.1.1 and FBC R905.1.1 requires use of metal cap nails where the ultimate design wind speed, V it, equals or exceeds 150 mph. 6.8.2 Optional, or if required by the Authority Having Jurisdiction: Install a leak barrier of LibertyTm SBS Self -Adhering Base/Ply Sheet; StormGuard® Film Surfaced Leak Barrier or WeatherWatch® Mineral Surfaced Leak Barrier at vulnerable leak areas, including but not limited to eaves, valleys, rakes, skylights and dormers. At eaves and valleys, install the leak barrier prior to installation of the underlayment. Along the rake, install the underlayment, leaving 6 to 8-inch of the deck exposed, and then install the leak barrier over the underlayment and exposed decking. At other areas, install the leak barrier over the underlayment. 6.9 VersaShield® Fire -Resistant Roof Deck Protection: 6.9.1 Shall be installed in compliance with the codified requirements for ASTM D6757 underlayment in FBC Table 1507.1.1 for the type of prepared roof covering to be installed. No hammer tacks or staples are permitted. 6.9.2 Optional, or if required by the Authority Having Jurisdiction: Install a leak barrier of LibertyTM SBS Self -Adhering Base/Ply Sheet; StormGuard® Film Surfaced Leak Barrier or WeatherWatch® Mineral Surfaced at vulnerable leak areas, including but not limited to eaves, valleys, rakes, skylights and dormers. At eaves and valleys, install the leak barrier prior to installation of the underlayment. Along the rake, install the underlayment, leaving 6 to 8-inch of the deck exposed, and then install the leak barrier over the underlayment and exposed decking. At other areas, install the leak barrier over the underlayment. NEW ETC, LLC Evaluation Report 01506.04.08-1114 Certificate ofAuthorization #32455 6T" EDITION (2017) FBC NON-HVHZ EVALUATION F1.10626-1114 GAF Roof Underlayments; (800) 766-3411 Revision 14: 06/05/2018 Page 8 of 11 OMEMO I etc. 6.10 Liberty'- SBS Self -Adhering Base/Ply Sheet: 6.10.1 Shall be installed in compliance with the codified requirements for ASTM D1970 underlayment in FBC Table 1507.1.1 for the type of prepared roof covering to be installed. 6.10.2 The minimum and maximum roof slopes are %:12 and 6:12, respectively. Back -nailing is required when slope is 1:12 or greater. Back -nailing shall consist of minimum 1-inch square or round cap nails spaced 18" o.c. within 3- inch side laps. 6.10.3 Non -Tile Applications: Shall be fully self -adhered to the substrates noted in Section 5.6. For direct -bond to deck applications plywood shall be primed with Matrix'" 307 Premium Asphalt Primer or alternate GAF accepted ASTM D41 primer at % to gallon per square. Prior to removal of release film, align sheets properly starting at the low -point of the roof (eave) with the selvage edge upslope and for minimum 2-inch overhang at eaves and rakes. Roll out sheet and allow to 'relax' for min. 30 minutes. Remove the lower piece of release film and bond to substrate and fold the overhanging 2-inch over the eave and nail into place 12" o.c. Remove the top piece of release film and bond to substrate. Install primed drip edge and fasten to meet FBC Chapter 16 wind load requirements. Install 1/8-inch troweling of Matrix'"" 201 Premium SBS Flashing Cement over drip edge. Continue upslope in a similar manner, maintaining minimum 3-inch side -laps and minimum 6-inch end -laps. Ensure all end laps are staggered at least 18-inch apart. Use a weighted lawn or linoleum roller to ensure complete adhesion to the substrate. Use a hand roller to firmly bond side and end laps. 6.11 StormGuard® Film Surfaced Leak Barrier: 6.11.1 Shall be installed in compliance with the codified requirements for ASTM D1970 underlayment in FBC Table 1507.1.1 for the type of prepared roof covering to be installed. 6.11.2 Back -nailing is required. Back -nailing shall consist of minimum 1-inch square or round cap nails spaced 18" o.c. within 3-inch side laps. 6.11.3 Non -Tile Applications: Shall be fully self -adhered to the substrates noted in Section 5.6. Prior to removal of release film, align sheets properly starting at the low -point of the roof (eave) with the selvage edge upslope and for minimum 2-inch overhang at eaves and rakes. Remove the lower piece of release film and bond to substrate and fold the overhanging 2-inch over the eave and nail into place 12" o.c. Remove the top piece of release film and bond to substrate. Install primed drip edge and fasten to meet FBC Chapter 16 wind load requirements. Install 1/8-inch troweling of Matrix'"" 201 Premium SBS Flashing Cement over drip edge. Continue upslope in a similar manner, maintaining minimum 3-inch side -laps and minimum 6-inch end -laps. Ensure all end laps are staggered at least 18-inch apart. Use a hand roller to firmly bond side and end laps. NEW ETC, LLC Evaluation Report 01506.04.08-R14 Certificate ofAuthorization #32455 6'" EDITION (2017) FBC NON-HVHZ EVALUATION FL10626-R14 GAF Roof Underlayments; (800) 766-3411 Revision 14: 06/05/2018 Page 9 of 11 ONEMOletc. 6.12 WeatherWatch® Mineral Surfaced Leak Barrier: 6.12.1 Shall be installed in compliance with the codified requirements for ASTM D1970 underlayment in FBC Table 1507.1.1 for the type of prepared roof covering to be installed. 6.12.2 WeatherWatch® Mineral Surfaced leak Barrier may be installed as a secondary water barrier using minimum 4- inch wide rolls to seal plywood deck joints prior to installation of the primary underlayment system. 6.12.3 Back -nailing is required. Back -nailing shall consist of minimum 1-inch square or round cap nails spaced 18" o.c. within 4-inch side laps. 6.12.4 Non -Tile Applications: Shall be fully self -adhered to the substrates noted in Section 5.6. Prior to removal of release film, align sheets properly starting at the low -point of the roof (eave) with the selvage edge upslope and for minimum 2-inch overhang at eaves and rakes. Remove the lower piece of release film and bond to substrate and fold the overhanging 2-inch over the eave and nail into place 12" o.c. Remove the top piece of release film and bond to substrate. Install primed drip edge and fasten to meet FBC Chapter 16 wind load requirements. Install 1/8-inch troweling of Matrix'"" 201 Premium SBS Flashing Cement over drip edge. Continue upslope in a similar manner, maintaining minimum 3-inch side -laps and minimum 6-inch end -laps. Ensure all end laps are staggered at least 18-feet apart. Use a hand roller to firmly bond side and end laps. 6.13 Ruberoid® Mop Granule; Ruberoid® Mop Granule FIR: 6.13.1 Ruberoid® Mop Granule or Ruberoid® Mop Granule FIR shall be installed in compliance with current GAF published installation requirements. 6.13.2 For use in tile applications, Ruberoid® Mop Granule or Ruberoid® Mop Granule FIR are for use as an alternate to Mineral Surface Roll Roofing" (ASTM D6380, Class M) in the "Single Ply System" from FRSA/TRI April 2012 (04- 12) beneath mechanically fastened the roof systems or the Hot Asphalt applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened or adhered tile roof systems. 6.13.3 Fully adhere in ASTM D312, Type IV hot -asphalt to the substrates noted in Section 5.6. Side laps shall be minimum 4-inch and end -laps minimum 6-inch wide, and offset end -laps minimum 3-feet from course to course. Side and end -laps shall be fully adhered in a complete mopping of hot asphalt with asphalt extending approximately 3/8-inch beyond the lap edge. 6.13.4 Consult GAF instructions regarding back -nailing requirements. 6.14 Tile Staging (Ruberoid® Mop Granule; Ruberoid® Mop Granule FR): 6.14.1 Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment. Refer to Table 2 herein, and GAF published requirements for tile staging. 6.14.2 Battens and/or Counter -battens, as required by the tile manufacturer and FRSA/TRI April 2012 (04-12) must be used on all roof slopes greater than 7:12. Precautions should be taken as needed, such as the use of battens or nail -boards, to prevent tile sliding and/or damage to the underlayment during the loading process. NEMO ETC, LLC Evaluation Report 01506.04.08-1114 Certificate ofAuthorization k32455 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL10626-1114 GAF Roof Underlayments; (800) 766-3411 Revision 14: 06/05/2018 Page 10 of 11 ON EMO I etc. As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this product. Contact the noted CIA agency for information on product locations covered for F.A.C. 61G20-3 CIA requirements. The following plants have qualified products under their respective physical properties specifications. Plant Specification Product Us Charleston, SC FBC 1507.1.1 (Exception) Tiger Paw'"" Roof Deck Protection Conover, NC ASTM D6757 VersaShield® Fire -Resistant Roof Deck Protection Dadra, India FBC 1507.1.1 (Exception) Tiger Paw— Roof Deck Protection Fontana, CA AC165 RoofPro`" SBS-Modified All -Purpose Underlayment Homer, LA FBC 1507.1.1 (Exception) Tiger PawTI Roof Deck Protection (WIP) McGregor, TX FBC 1507.1.1 (Exception) Shingle -Mate® Roof Deck Protection Mission, BC FBC 1507.1.1 (Exception) Tiger Paw'" Roof Deck Protection Mt. Vernon, IN ASTM D1970 Liberty- SBS Self -Adhering Base/Ply Sheet; StormGuard® Film Surfaced Leak Barrier; WeatherWatch® Mineral Surfaced Leak Barrier North Bay, Ontario FBC 1507.1.1 (Exception) Deck -Armor"" Premium Breathable Roof Deck Protection, StormSafeTM Anchor Sheet, Tiger PawT' Roof Deck Protection (conversion) Pryor, OK FBC 1507.1.1 (Exception) Shingle -Mate® Roof Deck Protection Savannah, GA ASTM D1970 StormGuard® Film Surfaced Leak Barrier; WeatherWatch® Mineral Surfaced Leak Barrier ASTM D6164 Ruberoid® Mop Granule; Ruberoid® Mop Granule FR 9, QUALITY ASSURANCE ENTITY: A• :4664-3281 END OF EVALUATION REPORT - NEMO ETC, LLC Evaluation Report 01506.04.08-1114 Certificate of Authorization #32455 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL10626-1114 GAF Roof Underlayments; (800) 766-3411 Revision 14: 06/05/2018 Page 11 of 11