Loading...
2511 Park Dr - BR18-004295 - REROOFDEPARTMENTCITY OF ORD FIRE Building & Fire Prevention Division 0 .1. 1 2018 PERMIT APPLICATION Application No: Documented Construction Value: $ -15-D 5 Z9 Job Address: 2511 Park Dr., Sanford, FL 32771 Historic District: Yes NoF-1 Parcel ID: 01-20-30-501-0200-0000 Residential Commercial Type of Work: New[] Addition Alteration Repair Demo Change of Use Move Description of Work: Remove and replace roof. Plan Review Contact Person: Phone: Fax: Email: Title: Property Owner Information Name EDWARDS, CLAUDE R Phone: 407-718-9565 Street: 2509 PARK DR City, State Zip: SANFORD, FL 32771 Resident of property? : Contractor Information Name Wormley Roofing Phone: 321-303-0766 Street: 2473 N John Young Pkwy, Fax: City, State zip: Orlando, FL 32804 Name: Street: City, St, Zip: Bonding Company: Address: State License No.: CCC1325558 Arch itectlEngineer Information Phone: Fax: E-mail: Mortgage Lender: Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: 6" Edition (2017) Florida Building Code Revised: January 1, 2018 Permit Application NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in ttie public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal. The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value, credit will be applied to your permit fees when the permit is issued. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Signature of Owner/Agent Date Print Owner/Agent's Name Notary Public State of Florida F Emma Victoria Campbell My Commission GG 184707 r »' Expires 02/11/2022 Owner/Agent is ' Personally Known to Me or Produced ID Type of ID Signature of Contractor/Agent Date . Kolwft Warts Print Contractor/Agent's Name yr Notary Public State of Florida Emma Victoria Campbell My Commission GG 184707 a ' Expires 02/11/2022 Contractor/Agent is kl— Personally Known to Me or Produced ID Type of ID BELOW IS FOR OFFICE USE ONLY Permits Required: Building Electrical Mechanical Plumbing[] Gas[] Roof Construction Type: Occupancy Use: Total Sq Ft of Bldg: Min. Occupancy Load: New Construction: Electric - # of Amps Fire Sprinkler Permit: Yes No APPROVALS: ZONING: ENGINEERING: COMMENTS: of Heads UTILITIES: Flood Zone: of Stories: Plumbing - # of Fixtures Fire Alarm Permit: Yes No WASTE WATER: FIRE: BUILDING: lo- .?r —45#1(4, Revised: January 1, 2018 Permit Application WORML:EY 2473 N. John Young Parkway • Orlando, FL 32804-! Officer (321) 303-0766 www.wormleyroofing_com '.' office@wormleyroofing.commV. m _ _. o M_ g......__ Professional Contractor•State Lic. CCC1325558•Fully lnsured+Uver 38 ;ears Experience PROPOSAL 1 INVOICE TO JOB ADDRESS j' Chip Edward Chip Edward ESTIMATE NO. 1584 1' DATE 09/05/2018 Proppsal good for 30 days. NO. DESCRIPTION AMOUNT 1 New Shingle Roof 5,858.00 2 Remove existing 2 shingle layers and underlayment to wood deck. 3 Inspect decking and re -nail to code. 4 Any wood deck repair is an additional charge per the following; i; Plywood deck replacement is $30 per sheet plus cost of materials. Board/Plank deck replacement is $3 per linear foot plus cost of materials. 5 Provide and install approved underlayment. Underlayment Type: 6 Provide and install new 26 gauge drip edge. COLOR: I 7 Provide and install new lead boots, goosenecks and flashing where needed. Color varies depending on shingle color. 8 Provide and install Starter Strips, and True Nip & Ridge. 9 Provide and install algae resistant architectural shingles. Brand: Color: 10 Provide and install GAF Cobra 3 shingles over ridge vents. 11 Remove and properly dispose of roofing debris from the job site. i 12 50 year limit life time manufactures warranty. 13 Wormley Roofing Inc. will provide a 5 year workmanship warranty. k PRICING INCLUDES ALL APPLICABLE FEES AND PERMITS. TOTAL I i' I We look forward to working with you! 40 i All Materials are guaranteed by the manufacturer. All work will be completed according to standard roofing practices and current building codes. Any alteration or deviation from the above specifications, will be only upon written orders and will become a written change — over i' and above this agreement. Although we will exercise all due cautions, we cannot be responsible for existing cracked driveways or damages due to rain, hail, wind or any acts of God. Any leaks that occur during the agreed workmanship !period will be repaired by Wormley Roofing Inc. Any repairs or alterations by others during the workmanship warranty period will vpid the warranty and WormleyI. Roof'tng*lnc. will not be hold responsible . Acceptance of Proposal: THE ABOVE PRICES, SPECIFICATIONS, TERMS AND CONDITIONS OF THIS PROPOSAL ARE SATISFACTORY AND ARE HEREBY ACCEPTED AND IS CONSIDERED A BINDING CONTRACT. WORMLEY ROOFING,INC. IS AUTHORIZED TO DO THE WORK AS SPECIFIED. I A 1/3 DOWN PAYMENT OF PROPOSED AMOUNT IS REQUIRED, TOTAL DUE UPON COMPLETION OF JOB, "PLUS COST OF ANY ADDITIONAL WOODWORK. OWNER ACKNOWLEDGES THAT HE/SHE HAS READ THE ROOFING PROPOSAL AND HAS RECEIVED A LEGIBLE COPY OF THIS AGREEMENT SIGNED BY CONTRACTOR, INCLUDING ALL'TERMS AND CONDITIONS HEREIN INCLUDED, BEFORE ANY WORK WAS COMPLETED. Accepted Bp Y= Date AcCeptec#: I is1NR1Approval: / r Date Approved: I f /s Down Payment Date ReceiviAmount: ct: Grant Maloy, erk Of The Circuit urt & mptrolle Seminole n t # 011812 2162 Book 9234 Pge 274; (C1oPAGES)rRCD 10/18/201Count19 30:43 AM THIS INSTRUMENT PREPARED BY: Name: Emma Campbell Address: 2473 N JOHN YOUNQ P KWA ORLANDO FL 32804 NOTICE OF COMMENCEMENT State of Florida County of Seminole CERTIFIED COPY GRANT MALOY CLERK OF THE CIRCUIT COURT '' 4ANDC0M11PTR .LER `I SENIINOLE CI` vTY, FLORIOA y f BY >t LERK Oa Permit Number: Parcel ID Number. 01-20-30-501-0200-0000 The undersigned hereby gives notice that improvement will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement. DESCRIPTION OF PROPERTY: (Legal description of the property and street address if available) 13LK 2 (LESS E 127.6 FT) SPURLING HEIGHTS PB 6 PG 19 2511 Park Dr., Sanford FL 32771 GENERAL DESCRIPTION OF IMPROVEMENT: Remove and replace roof. OWNER INFORMATION: Name: EDWARDS, CLAUDE R Address: 2509 PARK DR SANFORD, FL 32773-5106 Fee Simple Title Holder (if other than owner) Name: Address: CONTRACTOR: Name: ROBERT WORMLEY / WORMLEY ROOFING INC Address: 2473 N JOHN YOUNG PARKWAY, ORLANDO FL 32804 Persons within the State of Florida Designated by Owner upon whom notice or other documents may be served as provided by Section 713.13(1)(b), Florida Statutes. Name: In addition to himself, Owner Designates To receive a copy of the Lienor's Notice as Provided In Section 713.13(1)(b), Florida Statutes. Expiration Date of Notice of Commencement (The expiration date Is 1 year from date of recording unless a different date is specified) WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART I, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. Under penalties of perjury, I declare that I have read the foregoing and that the facts stated In It are true to the best of my knowled and belief. Florida Statute 713.13(1)(g):' The owner must aign the notice ofcommencement and no one else may be permitted to sign In his or her stead.' State of Ftlrija County of brA116k The foregoing instrument was acknowledged before me this day of by l ) E V "y—i Who is personally known to m0e, Name of person making statement OR who has produced identification type of identification produced: JNotaryPublicStateofFlorida Emma Vicforia Campbell Notary S naturec • My Commission GG I S47074, Expires 02/11/2022 SCPA Parcel View: 01-20-30-501-0200-0000 10/9/18, 3:29 PM di Pro ee Record Card Parcel: 01-20-30-501-0200-0000 Property Address: 2509 PARK DR SANFORD, FL 32771 Parcel 01-20-30-501-0200-0000 Owner(s) EDWARDS, CLAUDE R Property Address 2509 PARK DR SANFORD, FL 32771 Mailing 2509 PARK DR SANFORD, FL 32773-5106 Subdivision Name SPURLING HEIGHTS Tax District S1-SANFORD DOR Use Code 19-PROFESSIONAL SERVICE BLD Exemptions Legal Description BLK 2 (LESS E 127.6 FT) SPURLING HEIGHTS PB6PG19 Taxes Taxing Authority Assessment Value Exempt Values Taxable Value County General Fund 424,142 0 I 424,142 Schools i —_ _ -- .—.—_ _ 424,142 0 — -- 424,142 City Sanford j $424,142 0 424,142 SJWM(Saint Johns Water Management) 424,142 00--$424,142 County Bonds ------- T--- $ 424,142 0 i 424,142 Sales Description Date Book Page Amount Qualified Vac/Imp WARRANTY DEED 9/1/2000 03925 0479 i— t I $320,000 Yes Improved WARRANTY DEED 11/1/1982 01423 0225 45,000 No Improved WARRANTY DEED 18/1/1982 01411 0487 90,000 I Yes Improved Find Commmblo Sags 1 Land Method Frontage Depth Units Units Price Land Value http://parceIdetai1.scpaf1.org/ParceIDetaiIInfo.aspx?PID=01203050102000000 Page 1 of 2 LIMITED POWER OF ATTORNEY Altamonte Springs, Casselberry, Lake Mary, Longwood, Sanford, Seminole County, Winter Springs Date: I hereby name and appoint: Emma Campbell an agent of. Wormley Roofing Name of Company) to be my lawful attorney -in -fact to act for me to apply for, receipt for, sign for and do all things necessary to this appointment for (check only one option): The specific permit and application for work located at: 2511 Park Dr., Sanford, FL 32771 Street Address) Expiration Date for This Limited Power of Attorney: 1/1/2030 License Holder Name: Robert Wormley State License Number: CCC1 Signature of License Holder: STATE OF FLORIDA COUNTY OF The foregoing i strument was acknowledged before me this day of 200 1% , by M who is personally known to me or a who has produced as identification and who did (did not) take an oath. Signature Notary Seal) FmyvyA nm Print or type name tY 0% Notary Public State ofof Florida Notary Public -State of A Emma Victoria Campbell My Commission GG 184707 Commission No. (i 101 a Expires 0211112022 My Commission Expires: 2J r l Rev. 08.12) r City of Sanford Building and Fire Prevention Product Approval Specification Form I OFRCEPermit # rf-- Project Location Address 2511 Park Dr., Sanford, FL 32771 As required by Florida Statute 553.842 and Florida Administrative Code 9N-3, please provide the information and product approval number(s) on the building components listed below if they are to be utilized on the construction project for which you are applying for a building permit. We recommend that you contact your local product supplier should you not know the product approval number for any of the applicable listed products. Be aware that windows, skylights, and exterior doors must be tested in accordance with the Florida Building Code, Section 1714.5. More information about Statewide Product Approval can be obtained at www.floridabuilding.org. The following information must be available on the jobsite for inspections: 1. This entire product approval form 2. A copy of the manufacturer's installation details and requirements for each product. Category / Subcategory Manufacturer Product Description Florida Approval # include decimal 1. Exterior Doors Swinging Sliding Sectional Roll U Automatic Other 2. Windows Single Hun Horizontal Slider Casement Double Hun Fixed Awning Pass Through Projected Mullions Wind Breaker Dual Action Other June 2014 Category / Subcategory Manufacturer Product Description(including Florida Approval # decimal 3. Panel Walls Siding Soffits Storefronts Curtain Walls Wall Louver Glass block Membrane Greenhouse E.P.S Composite Panels Other 4. Roofing Products Asphalt Shingles Atlas Pristine FL 16305-R6 Underla ments Atlas Summit 60 FL 16226-R4 Roofing Fasteners Nonstructural Metal Roofing Wood Shakes and Shingles Roofing tiles Roofing Insulation Waterproofing Built up roofing System Modified Bitumen Single Ply Roof Systems Roofing slate Cements/ Adhesives / Coating Liquid Applied Roofing Systems Roof Tile adhesive Spray Applied Polyurethane Roofing E.P.S. Roof Panels Roof Vents GAF Cobra FL 6267-R14 Other June 2014 Category / Subcategory Manufacturer Product Description Florida Approval # include decimal 5. Shutters Accordion Bahama Colonial Roll u Equipment Other 6. Skylights Skylights Other 7. Structural Components Wood Connectors / Anchors Truss Plates Engineered Lumber Railing Coolers/Freezers Concrete Admixtures Precast Lintels Insulation Forms Plastics Deck / Roof Wall Prefab Sheds Other 8. New Exterior Envelope Products Applicant's Signature Applicant's Name Please Print) June 2014 1121I201iFloridaB dl^9 Code nine 17 i 3 1 6CIS Hone Log in q User R=_gis.retina Hot Topics Submit Surcharge Stzs & fa>s Publications FBC 5GR 1 I ECIS Site Map ', Lin'rs search Florida 9 C roduec Approval PERMIT JWUSER: Public user pF l rrecuct Aoa--0-0 Menu > Produa ar Aoalication s<_arn > Aod_ is=;ic,i Us-, Application Dot it wL FL±630S-R6 Application Type Revision Code version 2017 Application Status a Aooroved Comments Archived Product Menuadurer Address/Phone/Emaii Authorized 5ionature Technical Representative Address/Phone/Email Quality Assurance Representative Add ress/ Phorse/ Emeli Category Subcategory Compliance Method Florida Engineer of Architect Name who developed the Evaluation Report Florida License Quality Assurance Entity Quality Assurance Contract Expiration Oat Validatad By Certificate of independence Referenced Standard and Year (of Standard) Eouivalence act Product Standards certlea By Sections from the Code Atlas Roofing Corporation 20OG Rivet -Edge Parkway Suite 800 tlanta, GA 30328 770j ° 46-4571 mcoliinsC atlasroci ing.com Meidrin Collins mcoil ins@atlasrooPing. cam P. 00"nna Asphalt Shingles evaluation Report from a Florida Redisterec n] r'2ssionalEngineer valuation Report- Hardcopy Received Zachary P. Priest Pc- 74021 UL i_LC 12/ 31/2020 Locke Bowden Validation Checklist - Hardcopy Standard ASTM D 3161 ASTM D 3462 ASTM 0 7158 TAS 100 TAS 107 or a licensed Florida ti ear2016 20i0 301i 995 1995 i.. .: i..... .. _.-1... )..r .ann .: H...nn..^Jn.i.-art-.--...r cl/vn....r•. _.. r•v..- . .... ....-...... . _ .. __ .—. Florida Building Code Online Product Approval Method Method 1 Option D Date Submitted 09/3012017 Oate Validates; ?OJ03/20?7 Date Pending FaC Approval ID/oa/2017 Date Approved 121i2/201-7 6 5ummar+I of Products 1 Model, Number or iVarne i Description j 16305.1 i Atlas Shingles j Fiberglass reinforced laminated asphalt shingles Limits of Use [installation'anstrucions Approved for use in HVNZ: Yes i FL16305 Ro If ATLBOOT b 20 7 FoC Eval Report Shingle; Approved for use outside HVHZ: Yes [ einal.od ( , 3rnpac'c Resistant: N/A Verified. By: Zachary P. Priest-ia021 i Design Pressure., N/A Created by independent Third Party: Yes other; see evaluation reportfor limits of use I Evacuation Reports i FL16305 R6 AE ATL13007 6 7011 F13C Eval Report Sninales C; eated by Indepiand?ntYhird tyaY;:y: Yes. Contact Us :: 2601 Blair stone Road, Tallahassee r'i.32399 phone; 650-487-1824 ine ` elateo: Scrida is. an WaEo ennpiayE;. CoCvridht '007.3013 State of Florida :: privacy Statement ::.»CCesslbili Under Florida lave, Snail addressesarepublic records. iF You do notrriant your a -manaddress released in responseto a publ siito thisentity. Instead, contact the Ott -ice by phoneor bytradltfonal nail 't yeti have any questions, please contact 453?75(1),-lorida Statutes, eriective October ?, 2012, licensees licensed under Cn=_pter 435, F.S. must providethe pepar one, ins mailsprovidedmaybeusedforahic2alcancnuriicadan %%th tha.licensee. However crmil addresses are. public r_coaddrass, please providethe. Dipar:nert with an enact address mbici can be madeavailable to the public, To OPM—Inina if Y; pleasa clickhere . produclApprovalAccepts: ir1' E' go 5501 a Credit Card safe men.:: Ryund statement ords request, do not send Etectnnic 187.1,395. 'pursuant to Section vAthan enact addresstr they hace van do not veiab to supply a pers-onal a licensee-unler Chapter 455, F. S., r:` N' -n e llk HS-it E eat TECHNICAL SF_'#jF_S, LU EVALUATION REPORT Manufacturer: ATLAS ROOFING CORPORATION 2000 Riveredge Parkway, Suite 800 Atlanta, GA 30328 770) 612-6267 Manufacturing Plants: Hampton, GA Meridian, MS Dangerfield, TX Ardmore, OK Franklin, OH Quality Assurance: UL LLC (QUA9625) SCOPE Certificate of Authoriz-a!ationNo. 29824 17 20 Edinburgh Dr Tampa, FL 33647 j ( 813)480-3421 FLORIDA BUILDING CODE WH EDITION (2017) Issued September 30, 2017 i Category: Roofing Subcategory: Asphalt Shingles Code Sections 1504.1.1, 1507.2.5, 1507.2.7.1, 1523.6.5.1 Properties: Physical properties, Wind Resistance, Wind Driven Rain i PRODUCT DESCRIPTION Legend ( Ardmore) GlassMaster@ 30 Ardmore & Hampton) Tough - Master@ 20 Ardmore & Hampton) Pro - Cut@ Hip & Ridge Ardmore & Hampton) Pro - Cut@ Starter Strip Hampton) Prol- AMI'm Architectural Hampton, Franklin & Meridian) Pinnacle@ Pristine, Pinnacle@ Pristine Lifetime wl5cotchgard Dangerfield, Hampton, Franklin & Meridian) StormMaster@ Shake Dangerfield) ASTM D 3161, Class F fiberglass reinforced, 3-tab asphalt shingle with a dashed, thermally - activated, self-sealing sealant stripe that complies with AST( D 3462. ASTM D 3161, Class F fiberglass reinforced, 3-tab asphalt shingle with a dashed, thermally - activated, self-sealing sealant stripe that complies with ASTM D 3462. ASTM D 3161, Class F fiberglass reinforced, 3-tab asphalt shingle with a dashed, thermally - activated, self-sealing sealant stripe that complies with ASTM D 3462. ASTM D 3161, Class F fiberglass reinforced, hip and ridge dashed, thermally -activated, self-sealing sealant stripe that 3462. ASTM D 3161, Class F fiberglass reinforced, starter asphalt shingle thermally - activated, self-sealing sealant stripe that complies with A: ASTM D 3161, Class F & ASTM D 7158, Class H fiberglass reinforc architectural asphalt shingle with a dashed, thermally -activated, sell stripe that complies with ASTM D 3462. ASTM D 3161, Class F & ASTM D 7158, Class H fiberglass reinforc architectural asphalt shingle with two, dashed, thermally -activated, i stripes that complies with ASTM D 3462. ASTPA D 3161, Class F & ASTM D 7158, Class H fiberglass architectural modified asphalt shingle with two, dashed, thei sealant stripe that complies with ASTM D 3462. shingle with a with ASTM D i a dashed, D 3462. laminated alinct sealant laminated sealing sealant laminated ited, self-sealing ATL13002. 6 FL 16305-R6 i Page 1 of 11 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. Thisevaluationreportdoesnotexpressnorimplywarranty, installation, recommended use, or other product attributes that are not specifically addressed herein. RE 7 ATLAS 1E+^i ,NiCAL SERVICES, LLC StormMaster0 Slate ASTM D 3161, Class F & ASTM D 7158, Class H fiberglass rei Ardmore) architectural modified asphalt shingle with two, dashed, therma sealant stripe that complies with ASTM D 3462. REFERENCES 3 CORPORATION Asphalt Shingles laminated ited, self-sealing Entity Report No. Standard Year PRI Construction Materials Technologies (TST5878) ATL-079-02 01 ASTM D 3161 2016 TAS 107 1995 PRI Construction Materials Technologies (TST5878) ATL-083-02-01 TAS 100 1995 PRI Construction Materials Technologies (TST5878) ATL-086-02-01 Rev 1 ASTM D 3462 2010A PRI Construction Materials Technologies (TST5878) ATL-104-02-01 ASTM D 3462 2010A PRI Construction Materials Technologies (TST5878) ATL-106-02-01 ASTM D 3161 2016 TAS 107 1995PRIConstructionMaterialsTechnologies (TST5878) ATL-106-02-01 Rev 1 ASTM D 3161 2016 TAS 107 1995PRIConstructionMaterialsTechnologies (TST5878) ATL-107-02-01 TAS 100 1995 PRI Construction Materials Technologies (TST5878) ATL-107-02-01.1 TAS 100 j995PRIConstructionMaterialsTechnologies (TST5878) ATL-109-02-01 ASTM D 7158 2011 PRI Construction Materials Technologies (TST5878) ATL-116-02-01 ASTM D 3462 2010A PRI Construction Materials Technologies (TST5878) ATL-118-02-01 ASTM D 3462 2010A PRI Construction Materials Technologies (TST5878) ATL-119-02-01 TAS 100 1995 PRI Construction Materials Technologies (TST5878) ATL-123-02-01 ASTM D 7158 2011 PRI Construction Materials Technologies (TST5878) ATL-125-02-01 TAS 100 1995PRIConstructionMaterialsTechnologies (TST5878) ATL-127-02-01 Rev 1 ASTM 0 7158 2011 PRI Construction Materials Technologies (TST5878) ATL-132-02-01 ASTM D 3161 2016 TAS 107 995 PRI Construction Materials Technologies (TST5878) ATL-133-02-01 ASTM D 3161 2016 TAS 107 1995PRIConstructionMaterialsTechnologies (TST5878) ATL-135-02-01 ASTM D 3462 2010APRIConstructionMaterialsTechnologies (TST5878) ATL-136-02-01 ASTM D 3462 2010A PRI Construction Materials Technologies (TST5878) ATL-137-02-01 Rev 1 ASTM D 7158 011 PRI Construction Materials Technologies (TST5878) ATL-138-02-01 Rev 1 ASTM D 7158 011 PRI Construction Materials Technologies (TST5878) ATL-143-02-01 ASTM D 3161 7016 TAS 107 1995 PRI Construction Materials Technologies (TST5878) ATL-144-02-01 ASTM D 3161 2016 TAS 107 11995PRIConstructionMaterialsTechnologies (TST5878) ATL-151-02-01 ASTM D 3462 12010A PRI Construction Materials Technologies (TST5878) ATL-162-02-01 TAS 100 11995 PRI Construction Materials Technologies (TST5878) ATL-167-02-01 ASTM 0 3161 12016PRIConstructionMaterialsTechnologies (TST5878) ATL-168-02-01 ASTM D 3161 iM6 TAS 107 1995 PRI Construction Materials Technologies (TST5878) ATL-169-02-01 ASTM D 3462 12010A PRI Construction Materials Technologies (TST5878) ATL-170-02-01 ASTM D 3462 12010APRIConstructionMaterialsTechnologies (TST5878) ATL-171.02-01 ASTM D 3462 201QA PRI Construction Materials Technologies (TST5878) ATL-172-02-01 ASTM D 3462 i2010A PRI Construction Materials Technologies (TST5878) ATL-174-02-01 ASTM D 3462 i2010A PRI Construction Materials Technologies (TST5878) ATL-179-02-01 TAS 100 11995 PRI Construction Materials Technologies (TST5878) ATL-184-02-01 ASTM D 3161 2016 TAS 107 1'1995 PRI Construction Materials Technologies (TST5878) ATL-185-02-01 ASTM D 7158 12011 PRI Construction Materials Technologies (TST5878) ATL-186-02-01 TAS 100 11995PRIConstructionMaterialsTechnologies (TST5878) ATL-187-02-01 ASTM D 3462 2010A PRI Construction Materials Technologies (TST5878) ATL-220-02-01 ASTM D 3462 2010A PRI Construction Materials Technologies (TST5878) ATL-220-02-02 TAS 100 1995 PRI Construction Materials Technologies (TST5878) ATL-220-02-03 ASTM D 3161 12016 TAS 107 11995 PRI Construction Materials Technologies (TST5878) ATL-220-02-04 ASTM D 7158 2011 PRI Construction Materials Technologies (TST5878) ATL-221-02-01 ASTM D 3462 2010A PRI Construction Materials Technologies (TST5878) ATL-221-02-02 TAS 100 1995 PRI Construction Materials Technologies (TST5878) ATL-221-02-03 ASTM D 3161 i 2016 TAS 107 1995 PRI Construction Materials Technologies (TST5878) ATL-221-02-04 ASTM D 7158 i 2011 PRI Construction Materials Technologies (TST5878) ATL-222-02-01 ASTM D 3462 2010A PRI Construction Materials Technologies (TST5878) ATL-222-02-02 TAS 100 1995 PRI Construction Materials Technologies (TST5878) ATL-222-02-03 ASTM D 3161 2016 ATL73002.6 FL 16305-R6 Page 2 of 11 This evaluation report is provided for State of Florida product approval under Rule 61G20-0. The manufactdrer shalt WIN CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration forrw(iich this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. I l CREEK ECH 'CAL SERVtC=S. LL_C Entity PRI Construction Materials Technologies (TST5878) PRI Construction Materials Technologies (TST5878) PRI Construction Materials Technologies (TST5878) PRI Construction Materials Technologies (TST5878) PRI Construction Materials Technologies (TST5878) PR.t Construction Materials Technologies (TST5878) PRI Construction Materials Technologies (TST5878) PRI ConstructionMaterials Technologies (TST5878) PRI Construction Materials Technologies (TST5878) PRI Construction Materials Technologies (TST5878) Report No. ATL- 222-02-04 ATL- 223-02-01 ATL- 223.02-02 ATL- 223.02-03 ATL- 223-02-04 ATL- 224-02-01 ATL- 225-02-01 ATL- 225-02-02 ATL- 225-02-03 ATL- 225-02-04 ATLAS Standard TAS 107 ASTM D 7158 ASTM D 3462 TAS 100 ASTM D 3161 TAS 107 ASTM 0 7158 ASTM D 3462 ASTM D 3462 TAS 100 ASTM 0 3161 TAS 107 ASTM D 7158 G CORPORATION Asphalt Shingles gar 95 11 110A 195 116 195 111 i10A 110A 95 16 195 I11 ATL13002. 6 FL 16305-R6 ; Page 3 of 11 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. 1, a' CR M K a TFCH?,4!CAL SERViCFzS,1..LC INSTALLATION Legend Basic Wind Speed (V ll): Max. 194 mph Basic Wind Speed (Vasd): Max. 150 mph I I ATLAS ROOFING CORPORATION Asphalt Shingles I Deck (HVHZ): in accordance with FBC requirements; forSolidlysheathedmin. 19/32 in. plywood for wood plank new construction; Min. 15132 in. plywood existing construction. Deck (Non-HVHZ): In accordance with FBC requirements; j Solidly sheathed min. 15/32 in. plywoodlor wood plank for new construction; Min. 7/16 in. OSB existing Gonstruction. Underiayment: in accordance with FBC requirements. Min. slope: 2:12 and in accordance with FBC requirements. Contact the Atlas Roofing Corporation when installing at slope greater than 21:12. I Installation (HVHZ): installed with 5-inch exposure in accordance with RAS 115 and- manufacturer's published installation instructions. Shingles shall be attached using "6 Nall Pattern" detailed below. Installation (Non-HVHZ): Installed with 5Anch exposure in accordance with FBC requirements and manufacturer's published instructions. Shingles shall be attached installation using either "4 Nail Pattern" or `6 Nail Pattern" detailed below'. Il Figure 1. Legend 41 Nail Pattern (Non-HVHZ only) Figure 2. Legend 6 Nail Pattern AT1-13002.6 FL 16305-R6 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The man Technical Services, LLC of any product changes or quality assurance changes throughout the duration This evaluation report does not express nor imply warranty, installation, recommended use, or other p specifically addressed herein. ON Page d of 11 ar shall notify CREEK ch this report is valid. attributes that are not ON= K TF:C1-;911?.''iaL S'F?4ECrS, %mL%_ GlassMaster® 30 & Basic Wind Speed (Vint): Tough-Master®20 Basic Wind Speed (Vasa): Deck (HVHZ): Deck (Non-HVHZ): Underlayment: Min. slope: Installation (HVHZ): Installation (Non-HVHZ): ATLAS ROOFI G CORPORATION I Asphalt Shingles I Max. 194 mph Max. 150 mph In accordance with FBC requirements; Solidly sheathed min. 19/32 in. plywood for wood plank for new construction; Min. 15132 in. plywood existing construction. In accordance with FBC requirements; Solidly sheathed min- 15132 in. plywood jor wood plank for new construction; Min. 7/16 in. OSS existing construction. In accordance with FBC requirements. 1 2:12 and in accordance with FBC requirements. Contact the Atlas Roofing Corporation when installing at slope greater than 21:12. Installed with 5-inch exposure in accordance with RAS 115 and manufacturer's published installation instructions. Shingles shall be attached using "6 Nail Pattern" detailed below. Installed with 5-inch exposure in accdrdance with FBC requirements and manufacturer's puflished installation instructions. Shingles shall be attached using either 'A Nail Pattern" or "6 Nail Pattern" detailed below. A _ 12" to m 4 t It S f Y Figure 3. GlassMaster® 30 & Tough -Master@ 20 4 Nail Pattern (Non-HVHZ only) d hails P_=V M cRM min imp R;R_4 Vx- mcm F-W AEI OPP k'i3d 4 I C Figure 4. GlassMaster® 30 & Tough -Master® 20 6 Nall Pattern i ATL13002.6 FL 16305-R6 Page 5of 11 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product !attributes that are not specifically addressed herein. n a CREEK ATLAS ROOFING CORPORATION Asphalt Shingles i TEcs t^oCAL SER ICES. LLC ProLAMTm Architectural Basic Wind Speed (V,lt): Max. 194 mph Basic Wind Speed (Vak): Max. 150 mph Deck (HVHZ): in accordance with FBC requirements; Solidly sheathed min. 19/32 in. plywood ior wood plank for new construction: Min. 15/32 in. jplywood existing construction. Deck (Non-HVHZ): In accordance with FBC requirements; i Solidly sheathed min. 15132 in. plywoodl or wood plank for new construction; Min. 7116 in. OSB existing construction. Underlayment: in accordance with FBC requirements. Min. slope: 2:12 and in accordance with FBC requirements. Contact the Atlas Roofing Corporation when installing at slope greater than 21:12. Installation (HVHZ): Installed with 6 in. exposure in accordance with RAS 115 and manufacturer's publishedinstallation instructions. Shingles shall be attached using "6 Nil Pattern" detailed below. Installation ( Non-HVHZ): Installed with 6 in. exposure in accordance with FBC requirements and manufacturer's published installation instructions. Shingles shall be attached lusing either "4 Nail Pattern" or -6 Nail Pattern" detailed below. 1 i SticGLE. Si" SS`W14T UNE PATTERN I Ills LEf>LGT:iO;H: 1 ' OFF 1 i wg I i Figure 5. ProLAMT"' Architectural Shingle 4 Nail Pattern (non-HVHZ only) i • i .. , p I J 14 I 6.- 1 + 1- 16 0 @ A i k Figure 6. Pro-LAMT'" Architectural Shingle 6 Nail Pattern ATL13002.6 FL 16305-R6 Page 6 of 11 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any productchanges or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty; installation, recommended use, or other product attributes that are not specifically addressed herein. tt3v eN RLEEKgT;rCHNICAL. SERVICES, LI_% Pinnacle® Pristine & Basic Wind Speed (Vast): StormMaster@ Shake Basic Wind Speed (Veld): Deck (HVHZ): Deck (Non-HVHZ): Underlayment: Min. slope: Installation (HVHZ): Installation (Non-HVHZ): ATLAS ROOFING CORPORATION 4 Asphalt Shingles Max. 194 mph Max. 150 mph In accordance with FBC requirements; Solidly sheathed min. 19/32 in. plywood or wood plank for new construction; Min. 15/32 in. plywood existing construction. i In accordance with FBC requirements; Solidly sheathed min. 15/32 in. plywood or wood plank for new construction; Min. 7/16 in. OSB exis, g construction. In accordance with FBC requirements. 2:12 and in accordance with FBC requirements. Contact the Atlas Roofing Corporation when installing at slope greater than 21:12. Installed with 6 in. exposure in accordance with RAS 115 and manufacturer's published installation instructions. Shingles shall be attached using "6 Nair Pattern" detailed below. i Installed with 6 in. exposure in accordance with FBC requirements and manufacturer's published installation instructions. Shingles shall be attached using either "4 Nail Pattern" or "6 Nail Pattern" detailed below. a i U_ELE SEALANT U"E rATTF +.Id i Sop: 1 LENGTH UN: 3 4FF I i 3070%:: LENGTH ON; 1" OF I I at3 - z. lP 1..... .. .... -_ ram- ®o o -.... C GM-1 -... L @ O cmc6m 4I Figure 7. Pinnacle® Pristine and StormMaster@ Shake 4 Nail Pattern (Non-HV6 only) 4 2" SE" T uPE=Atic k CP: ,. UNIGTH M S 0 Ff 20irQ?: LENGrH ON! t" 6FF rk tire-. t...!•.a fc--.r-...-t- -E3."t_,®_. > 'ii 'E]'-9- Ex n ->t;...(3--D'-- C e i I l Figure 8. Pinnacle® Pristine and StormMaster® Shake 6 Nail Pattern ATL13002. 6 FL 16305-R6 Page 7 of 11 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify GFLEEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which`this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. i CREEK T--c.'mt-41CAL SERVICES. LLC StormMaster® Slate ATL13002.6 Basic Wind Speed (V,„): Basic Wind Speed Deck (HVHZ): Deck (Non-HVHZ): Underlayment: Min. slope: Installation (HVHZ): Installation (Non-HVHZ): ATLAS ROOFING CORPORATION Asphalt Shingles Max. 194 mph Max_ 150 mph In accordance with FBC requirements; 1 Solidly sheathed min. 19/32 in. plywoodior wood plank for new construction; Min. 15132 in. !plywood existing construction. 1 In accordance with FBC requirements; Solidly sheathed min. 15/32 in. piywoodlor wood plank for new construction; Min. 7116 in. OSB existing construction. In accordance with FBC requirements. I 2:12 and in accordance with FBC requirements. Contact the Atlas Roofing Corporation when installing at slope greater than 21:12. 1 Installed with 8.5 in. exposure in accordance with RAS 115 and manufacturer's published installation instructions. Shingles shall be attached using "6 Naii Pattern" detailed below. Installed with 8.5 in. exposure in accordance with FBC requirements and manufacturer's published installation instructions. Shingles shall be attached using either "4 Nail Pattern" or "6 Nail Pattern" detailed below. Figure 9. StormMaster® Slate 4 Nail Pattern Figure 10. StormMaster® Slate 6 Nail Pattern FL 16305-R6 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufactui Technical Services, LLC of any product changes or quality assurance changes throughout the duration for wF This evaluation report does not express nor imply warranty, installation,, recommended use, or other product specifically addressed herein. Page 8 of 11 shalt notify CREEK i this report is valid. tributes that are not CREEK ATLAS ROOFING CORPORATION TECHN5CAL SERVICES. L Asphalt Shingles Pro•Cut® Starter Strip Basic Wind Speed (V lt): Max. 194 mph jBasicWindSpeed (Vasd): Max. 150 mph Deck (HVHZ): In accordance with FBC requirements: Solidly sheathed min. 19/32 in, plywood or wood plank for new construction. Min. 15132 in. plywood existing construction. Deck (Non-HVHZ): In accordance with FBC requirements; Solidly sheathed min. 15/32 in. plywood• or wood plank for new construction; Min. 7116 in. OSB existing construction. Underlayment: In accordance with FBC requirements. Min, slope: 2:12 and in accordance with FBC requirements. Contact the Atlas Roofing Corporation when installing at slope Installation (HVHZ): greater than 21:12. Installed in accordance with RAS 115 and manufacturer's Published installation instructions. Shingles shall be attached as shown below. Installation (Non-HVHZ): Installed in accordance with FBC requirements and manufacturer's published installation instructions. Shingles shall be attached as shown below. I' n S L'. 11z"ic; sia-.Y rail f = _ — _ — — Figure 11. Pro -Cut® Starter Strip ATL13002.6 FL 16305-R6 i Page 9 of 11 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEKTechnicalServices, LLC of any product changes or quality assurance changes throughout the duration for whifih this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product ttdbutes that are notspecificallyaddressedherein. CREEKx. Pro -Cut@) Hip & Ridge ATL13002.6 Basic Wind Speed. (V It): Basic Wind Speed (V3,a): Deck (HVHZ): Deck (Non-HVHZ): Underlayment: Min. slope: Installation (HVHZ and non-HVHZ): ATLAS ROOFING CORPORATION Asphalt Shingles Max. 194 mph i Max. 150 mph In accordance with FBC requirements; Solidly sheathed min. 19/32 in. plywood or wood plank for new construction; Min. 15/32 in. ,plywood existing construction. In accordance with FBC requirements; Solidly sheathed min. 15/32 in. plywood or wood plank for new construction; Min. 7/16 in. OSB existing construction. In accordance with FBC requirements. 1 2:12 and in accordance with FBC requireir(nents. Installed with 5-5/8 inch exposure in accordance with RAS 115 (HVHZ only) and manufacturer's published installation instructions. The direction of the exposed end shall be away from the prevailing wind. ( . i 1 f 12 ga_ 2-112" rina i shank nail i i Figure 12. Pro -Cut® Hip & Ridge FL 16305-R6 Page 10 of 11 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK ATLAS ROOF,ING CORPORATIONAsphaltShingles TECHNICALLAICAL SERVICES, LLC LiMiTATiONS I 1) Fire Classification is not within the scope of this: evaluation. 2) The roof deck and the roof deck attachment shall be designed by others to meet the minlimum design loads established for components and cladding and in accordance with FBC requirements. 3) The mean roof height shall be restricted to a maximum 33 ft in the HVHZ. 4) Classification to ASTM D 7158 applies to exposure B & C with a building mean roof height of 33-ft or less. 5) Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck shall be checked for protrusion and corrected prior to underiayment application. 6) Shingles shall be installed starting at the eave in horizontal layers such that the laps shied water from the deck_ 7) Installation of the evaluated products shall comply with this report, the FBC, and Ithe manufacturers published application instructions. Where discrepancies exist between these sources, the more restrictive and code compliant detail shall prevail. 1 8) All products listed in this report shall be manufactured under a quality assurance program in compliance withRule61G20-3. i 1COMPLIANCESTATEMENT The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance withjthe Florida Building Code, 61" Edition (2017) as evidenced in the referenced documents submitted by the named manufacturer. y11111111111 E N No 74021 JG'. STATE OF :UJ os°+CCU ;c O R t O N Al°°° CERTIFICATION OF INDEPENDENCE CFI Zachary R. Priest; P.E. Florida Registration No. 74 Organization No. ANE9641 CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company mar products under this evaluation. CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or di this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturinc under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the product. END OF REPORT ATL13002.6 FL 16305-R6 This evaluation report is provided for State of Florida product approval under Rule 611320-3. The man Technical Services, LLC of any product changes or quality assurance changes throughout the duration This evaluation report does not express nor imply warranty, installation, recommended use, or other p specifically addressed herein. or distributing products under distributing products process of the 11 of 11 ich this report is valid. attributes that are not ProduuE Approval FMCEUSER: Public User Prad:xt Acorovai Henu > Praductat Acaii.Cation search > Aoolication List > Application Detail FL _ FL16226-R4 Application Type Revision Code Version 2017 Application Status Approved Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Florida Engineer or Architect Name who developed the Evaluation Report Florida License Quality Assurance Entity Quality Assurance Contract Expiration Date Validated By Certificate of independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Publications -FBC SMff=5CI5SSSite Mao ' LUnits search I PERMIT ## Ik- Atlas Roofing Corporation 2000 Rhrertdge Parkway Suite 800 Atlanta, GA 30328 770) 946-4571 mcailins@atiasrooffing.com Meldrin Collins mcotilns@atlasroofmg.com Paul Casserl 2000 Rivereage Parkway Suite 800 Atlanta, GA 30328 678) 402-9632 pcesseri@atiasroofiric.com Roofing Underlayments Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report- Hardcopy Received Zachary R.Priest PE-74021 UL LLC 12%31/2020 Locke Bowden Validation Checklist - Hardcopy Received FL1 6226 44 COI ATL1300* a 2017 FBC Product Evaluation Report final. dr Standard Year ASTM D 226 2009 ASTM D 6757 20?6 t121l26i'7 Florida Building Code Online Sections from the Code Product Aoprovai Method i~lethod 1 Option D Dace Submi wed 10/02/2017 Date Validated 10/03/2017 Date Pending FBC Approval i0/09J20_7 Date Approved 1-2112/2017 Summary of ProductsI FLY i Model, Number or Name Description 16225.1 I Gorilla Guard EverFelt Spec 30 i ASTM D 6757 & ASTM D 226, Type 11 underlayment Limits of Use 1 installation InstructionsApprovedforuseinHVHZ: Yes FL16226 R4 11 ATL13001.4 2017 FBC Product EvaluationApprovedfaruseau"side HVHZ: Ye; Reoort Final.od` i impact Resistant: N/A : Verified By: Zachary R. Priest 74021 iDesignPressure: N/A Created by Independent Third Party_ YesOther. Sec evaluation report for limits of use evaluation Reports FL16226 R4 AE ATL130011.4 2017 FBC Product Evaluation Reoort final.odf If Created by independent Third Party: Yes Contact Us :: 28o? elalr Stole Ro2d eilahass a FL 270C Phone. 850-487-182e T'ne state of Florida isan AA/EMemployer. Coovrioht 2007-7013 state o"Icida :: Pmracv Statement :: Accessih;litv5tatamant :: Refund Statement Under Florida law, email addresses arePublic records.. it YOU do not Want your e-mail address released in response to a public -records requast, do not send electronicmailt0thisentity. instead, contact the officis by phone or by t2dtion'al mil. If you have any questions, please contact B50.487.1345. Pursuant to Section453.273(1), norida Statutes, r:iiedive fJCnbar 1, 2012, licensees licensed under Chapter455, F.S. must provide the Department :Ath an email address if they haveOne. The emalis provided may be used for ofsltial c0:mmunication with the licensee. However email addressesare public record. Ir you. do not wishto supply a personaladdress, please provide_ the Department with an email address .lhith can -be made available to the public. To determine if you era a ecensee under Chapter 955, ES., vlease click here • Product Approval Accepts: CEEEL] Q F:fEtl Credit Card. sale Certificate of Authorization No. 29824 r 17520 Edinburgh DrRE" K Tampa, FL 33647 TECHNICAL SERVICES, LLC (813) 480-3421 EVALUATION REPORT FLORIDA BUILDING CODE, 6r" EDITION (2017) Manufacturer: Atlas Roofing Corporation Issued October 1, 2017 2000 Riveredge Parkway, Suite 800 Atlanta, GA 30328 770)612-6267 http://w-i4w.atias.-oofinci.com Manufacturing Plants: Meridian, MS Calgary, Alberta Canada Dadra and Nagra Haveli , India Quality Assurance: UL LLC (QUA9625) SCOPE Category: Roofing Subcategory: Underlayments Code Sections: 1507.1.1, 1518.4 Properties: Physical properties REFERENCES Kaifty Report No. Standard Year PRI Construction Materials Technologies (TST5878) ATL-033-02-01 ASTM D 226 2009 PRI Construction Materials Technologies (TST5878) ATL-101-02-01 ASTM D 6757 2016 ASTM D 226 2009 TAS 117(B) 1995 ASTM D 1781 1998(2012) PRI Construction Materials Technologies (TST5878) ATL-134-02-01 ASTM D 6757 2016 ASTM D 226 2009 ASTM D 4869 2016 PRI Construction Materials Technologies (TST5878) ATL-209-02-01 ASTM D 6757 2016 ASTM D 226 2009 ASTM D 4869 2016 PRODUCT DESCRIPTION Gorilla Guard® ASTM D 6757 and ASTM D 226, Type 11 mechanically fastened underlayment made from EverFelt Spec 30 asphalt -saturated organic felt reinforced with glass fiber for steep slope roof applications. Rolls are a nominal 36-inch wide by 72-ft long. Unless otherwise noted, the following application details shall be followed for New and Existing construction. ATL13001.4 FL16226-R4 Page 1 of 3 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. ATLAS ROOFINGlf: Jjk g CORPORATIONREEKUnderlayments9' TECHNICAL SERVICES, LLC APPLICATION INSTRUCTIONS Deck: The roof deck shall be constructed of closely fitted, solid sheathing for new or existing construction. New construction in the HVHZ shall be min. 19/32 in. plywood. Sheathing shall be installed in accordance with FBC requirements. Roof decks shall have no more than 1/8" gap at abutting joints. Attachment (HVHZ): Underlayment shall be installed with a minimum 4-inch head lap and minimum 6-inch end lap and be fastened as specified in FBC Section 1518.2. Attachment (Non-HVHZ): Underlayment shall be attached in accordance with the FBC Table 1507.1.1 and manufacturer's installation instructions Allowable roof coverings: Mechanically attached asphalt shingles, metal roof panels and shingles, wood shakes and shingles, and slate shingles. Clay and concrete tiles are allowable when installed with ASTM D 6830, ASTM D 249 organic cap sheet, or other approved underlayments in accordance with FBC requirements. LIMITATIONS 1) Fire Classification is not within the scope of this evaluation. 2) Wind uplift resistance in not within scope of this evaluation. 3) Installation of the evaluated product shall comply with this report, the FBC, and the manufacturers published application instructions. Where discrepancies exist between these sources, the more restrictive and FBC compliant installation detail shall prevail. 4) Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck shall be checked for protrusion and corrected prior to underlayment application. 5) Roof slope limitations shall be in accordance with FBC requirements. 6) The roof deck shall be constructed of closely fitted sheathing for new or existing construction. Roof deck shall be installed in accordance with FBC requirements. 7) All underayments shall be installed with the roll length parallel to the eave, starting at the eave, and lapped in success courses installed up the deck in a manner that effectively sheds water from the deck. End laps shall be staggered between courses in accordance with the manufacturer's application instructions. 8) Roof coverings shall not be adhered directly to the underlayment. 9) The underlayment may be used as described in other current FBC product approval documents. 10) The underlayment shall be exposed on the roof deck for a maximum 30 days unless otherwise stated. 11) All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61 G20-3. ATL13001.4 FL16226-R4 Page 2 of 3 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. ATLAS ROOFING CORPORATIONCREEKUnderlayments TECHNICAL SERVICES, LLC COMPLIANCE STATEMENT The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building Code, 6th Edition (2017) as evidenced in the referenced documents submitted by the named manufacturer. 2017.10.0 ti. No 74021 1 17:08:37 04'00' i gip•• STATE OF : CT••. o P•: \ OR Zachary R. Priest, P.E. i F i'•• ti, C? Np,; . Florida Registration No. 74021 organization No. ANE9641E` CERTIFICATION OF INDEPENDENCE CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. i END OF REPORT ATL13001.4 FL16226-R4 Page 3 of 3 This evaluation report is provided for State of Florida product approval under Rule 611320-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. 4/6/2018 Florida Building Code Online q 4 y A.ti, + ad'-p i Y..;a ,.; - r `. ... i .,.•, ;` Y 1 . "'" r{Fj jt ,rs t. r 8cIS. Home J Log In J user RegistrationI Hot Topics J Submit Surcharge i Slats & Facts 1 Publications i FBC Staff I= BCIS Site Map Links J Search J d""' f1 rich nyp j.,xl Product Approval USER: Public user product Aooroval Menu > Product or Aopifcation Search > Application List > Application Detail FL # FL6267-R14 Application Type Revision Code Version 2017 Application Status Approved Comments Archived Product Manufacturer GAF Address/Phone/Email 1 Campus Drive Parisppany, NJ 07054 800) 766-3411 mstieh@gaf.com Authorized Signature Robert Nieminen lindar@nemoetc.com Technical Representative William Broussard Address/Phone/Email i Campus Drive Parsippany, NJ 07054 800)766-3411 TechnicalQuestionsGAF@gaf.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Roofing Accessories that are an Integral Part of the Roofing System Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed Robert Nieminen the Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 03/23/2019 Validated By John W. Knezevich, PE Validation Checklist - Hardcopy Received Certificate of Independence FI 6267 R14 COI 2017 Ot COI Nieminen.l Referenced Standard and Year (of Standard) standard year ASTM E330 2002 ASTM G155 2005 TAS 100(A) 1995 TAS 110 2000 TAS 114, Appendix E 1995 Equivalence of Product Standards Certified By https:llwww.florid abuildi ng.org/pr/pr_app_dtl.aspx?param=wGEvXQwtDqu02YBW7bM8MZAecpwXirhugwRt)(JeyrZzLC%2fAdAOd HSA%3d%3d 1! 4/6/2018 Florida Building Code Online Sections from the Code Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved FL # 6267.1 Method 1 Option D 09/25/2017 09/30/2017 10/08/2017 12/12/2017 Model, Number or Name GAF Roof Ventilation Products Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-215 Other: 1.) The noted design pressures applies to one particular vent installation. Refer to Section 5.4 for heightlimitationsand/or Section 5.5 for vent installations and allowable design pressures. 2.) Refer to ER Section 5 for Urnits of Use. Description Low profile roof ridge vents Installation InstructionsFl6267R14I101709 FINAL GAF Ventilation FL6267- R14, pdf Verified By: Robert Nieminen PE-59166 Created by Independent Third Party: Yes Evaluation ReportsFLow7R14AL2017 09 FINAL cAP Ventilation FL6267-_ R14.Rdf Created by Independent Third Party: Yes 3ac!: West Contact Us :: 2601 Blair Stone Road Tallahassee FL 3.W-Ph2n^' R50-487_-LW The State of Florida is an.AAIEEO employer, CopyIlghr 2007-2013 State df Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement under Florida law, email addresses are public records. If you do notwant your e-mail address released in response to a public -records request, do not send electronicon mail to this entity. Instead, effective October 1, 201122, licenseesrinsed (under Chaptemail. if you lr 4SSave F.S.nymush provide he Departmons, pleasecontactent with an5email address if - -Pursuanttothey have wish to Supply a 455.275(1), Florida Statutes, one. The please provide dethe Department with ancommunicationemaaddres which can the licensee. made available able tothe apublic. Todetermine n oua eya licenseou do e under Chapter 455, F.S., please dick here . Product Approval Accepts: Credit Safe https: llwww. floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDquO2YBW7bM8MZAecPwXirhugwRtXJeyrZzLCa/a2fAdAOdHsA%3da/a3d L TRII 'm ERD GAF 1 Campus Drive Parsippany, NJ 07054 800) 766-3411 EXTERIOR RESEARCH & DESIGN, LLC. Certificate of Authorization #9503 353 CHRISTIAN STREET, UNIT #13 OXFORD, CT 06478 203) 262-9245 tvamaTivn InePUra viwW-- -- --_— FL6267-R14 Date of issuance: 02/28/2006 Revision 14: 09/25/2017 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 61h Edition (2017) Florida Building Code sections referenced herein. DESCRIPTION: GAF Roof Ventilation Products LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referencedQualityAssurancedocumentationchanges, or provisions of the Code that relate to the product change. Acceptance ofthisEvaluationReportbythenamedclientconstitutesagreementtonotifyRobertNieminen, P.E. if the productchangesorthereferencedQualityAssurancedocumentationchanges. Trinity I ERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinitylERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer oritsdistributorsandshallbeavailableforinspectionatthejobsiteattherequestoftheBuildingOfficial. This Evaluation Report consists of pages 1 through 12. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCAANE1983 The facslmile seal appearing was authorized by Robert Nieminen, P.E. on 09/75/2017. This does not serve as an electronically signed document. signed, sealed hardcopies have been transmitted tothe Product Approval Administrator and tothe named client CERTIFICATION OF INDEPENDENCE: ill it acquire, a financial interest in any company manufacturing or 1. TrinitylERD does not have, nor does it intend to acquire or w distributing products it evaluates. 2. TrinitylERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates: ompany manufacturing or distributing products for 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any c which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither TrinitylERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for anyprojectonwhichthisEvaluationReport, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. TRINITYI; ERD ROOFING COMPONENT EVALUATION: 1. SCOPE: Product Category: Roofing Sub - Category: Roofing Accessories that are an Integral Part of the Roofing System Compliance Statement: GAF Roof Ventilation Products, as produced by GAF, have demonstrated compliance with thefollowingsectionsofthe61hEdition (2017) Florida Building Code through testing in accordance with the followingStandards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Pro ert Standard Year 1504. 3 Wind ASTM E330 2002 19951995 1506.5 / 1517.5.1 Corrosion Resistance (of nails) TAS 114, Appendix E 1523. 6.5.2.13 Wind Driven Rain TAS 100(A) 2000 1523. 6.5.2.13.1 Physical Properties TAS 110 2005 2615. 2 Weatherometer ASTM G155 3. REFERENCES: Entity Examination Reference Date 03/ 02/2004 ATI ( TST 1558) Physical Properties 01-49035.01 01/ 15/2004 ATI ( TST 1558) Wind Driven Rain 01-44964.01 60172. 01-122-18 10/07/2005 ATI ( TST 1558) Wind Driven Rain 59665. 02-106-31 ATI (TST 1558) Physical Properties 84608. 01-106-18 11/1 12/ 200/ 2008 ATI ( TST 1558) Wind Driven Rain Wind Driven Rain A5250.01-109-18 02/18/2011 ATI ( TST 1558) ATI ( TST 1558) Wind Uplift 87074.01-109-44 12/03/2008 11/ 05/2012 ATI ( TST 1558) Wind Uplift C2396.01-109-44 D1957. 01-109-44 03/04/2014 ATI ( TST 1558) Wind Uplift Wind Uplift E0818.01-109-44 09/23/2014 ATI ( TST 1558) ATI ( TST 1558) Physical Properties D2702.01-106-18 06/30/2014 04/ 30/2015 ATI ( TST 1558) Wind Uplift E6744.01-109-44 01/ 10/2017 ATI ( TST 1558) Wind Driven Rain G2331.01-109-44 01/ 10/2017 ATI ( TST 1558) Wind Driven Rain G4123.01 109-18 01/ 10/2017 ATI ( TST 1558) Wind Uplift G4123.02-109-44 06/ 24/2004 PRI ( TST 5878) Weatherometer HBP-007-02-01 06/ 06/2001 PRI ( TST 5878) Physical Properties HBP-002-02-01 11/ 02/2000 PRI ( TST 5878) Wind Driven Rain HBP-01-02-01 12/ 31/2003 PRI ( TST 5878) Wind Driven Rain BRY-021-02-01 09/ 17/2004 PRI ( TST 5878) PhysicalProperties BRY-025-02-01 GAF- 138-02-06 02/09/200702/09/2007 PRI (TST 5878) Physical Properties GAF- 138-02-04 PRI (TST 5878) Wind Driven Rain GAF- 310-02-01 07/07/2011 PRI ( TST 5878) Wind Driven Rain ETC- 01-718-10379.0 01/16/2000 ETC Labs (TST 2411) Physical Properties ETC- 03-718-14602.0 01/20/200409/27/2007 ETCLabs (TST 2411) Physical Properties ETC- 07-718-19959.0 ETCLabs (TST 2411) Physical Properties Various NOAs Current Miami - Dade (CER 1592) CER 1592) Various Corrosion Resistance (of nails) Certification L 17-0606.01 06/26/2017 Miami - Dade Miami - Dade (CER 1592) Corrosion Resistance (of nails) Certification L 17-0821.08 09/25/201705/07/2015 Miami Dade (CER 1592) Corrosion Resistance (of nails) 03/23/2016 UL, LLC. (QUA 9625) Quality Control Inspection Report, R15072, GAl Inspection Report, R15072, GA2 04/15/2016 UL, I.I.C. (QUA 9625) Quality Control Service Confirmation, R15072, NC 06/08/2017 UL, LLC. (QUA 9625) Quality Control Evaluation Report 01506.02.06-1134 Exterior Research and Design, LLC. 6T EDITION (2017) FBC NON-HVHZ EVALUATION FL6267-R14 Certificate of AuthorizationN9503 Roof Ventilation Products; 800) 766-3411 Revision 14: 09/25/2017 GAF Page 2 of 12 Cal i TRINITY j ERD PRODUCT DESCRIPTION: 4.1 Cobra® Exhaust Vent is a low -profile attic ridge vent of mesh -construction for use in shingle roof systems. The product measures 10%-inch wide supplied in 20 and 50 ft long rolls, and is supplied with corrosion resistant 1%-inch coil nails (nail gun version) or 2'/:-inch Smart Nails'" (hand nail version). Cobra® Exhaust Vent has a published net free ventilation area (NFVA) of 14.1 inZ / lineal foot for nail gun version and 16.9 in' / lineal foot for hand nail version. 4.2 Cobra® Rigid Vent 31" is a plastic, low -profile attic ridge vent for use in shingle roof systems with 12-inch width ridge caps. The product measures 13-13/16-inch wide supplied in 48-inch long sections, and issuppliedwith3-inch corrosion resistant ring shank nails. Cobra® Rigid Vent 3'" has a published net free ventilation area (NFVA) of 18 inZ / lineal foot. 4.3 Cobra® Rigid Vent 31 - 9" is a plastic, low -profile attic ridge vent for use in shingle roof systems with 10- inch width ridge caps. The product measures 11Y:-inch wide supplied in 48-inch long sections, and issuppliedwith3-inch corrosion resistant ring shank nails. Cobra® Rigid Vent 31 - 9" has a published net free ventilation area (NFVA) of 18 inZ / lineal foot. 4.4 Cobra® Snow Country'" is a plastic, low -profile attic ridge vent with filter for use in shingle roof systems. The product measures 13-13/16-inch wide supplied in 48-inch long sections. Cobra® Snow Country"" has a published net free ventilation area (NFVA) of 18 in / lineal foot. 4.5 Cobra® Snow Country Advanced'" is a plastic, low -profile attic ridge vent with filter for use in shingle roofsystemswith12-inch width ridge caps. The product measures 13-13/16-inch wide supplied in 48-inch long sections, and is supplied with 3-inch corrosion resistant ring shank nails. Cobra® Snow Country Advanced'" has a published net free ventilation area (NFVA) of 18 inZ / lineal foot. 4.6 Cobra® Snow Country Advanced- - 9" is a plastic, low -profile attic ridge vent with filter for use in shingle roof systems with 10-inch width ridge caps. The product measures 11Y2-inch wide supplied in 48-inch long sections, and is supplied with 3-inch corrosion resistant ring shank nails. Cobra® Snow Country Advanced' - 9" has a published net free ventilation area (NFVA) of 18 inZ / lineal foot. 4.7 Cobra® RidgeRunner® is a polypropylene plastic, low -profile attic ridge vent for use in shingle roofsystems. The product measures 11%-inch wide supplied in 20 ft long rolls, and is supplied with corrosionresistant1%-inch coil nails. Cobra® RidgeRunner® has a published net free ventilation area (NFVA) of 12.5 inZ / lineal foot. 4.8 TruSlate® Ridge Vent is a plastic, low -profile attic ridge vent for use in TruSlate® roof systems. Theproductmeasures11.4-inch wide supplied in 48-inch long sections. TruSlate® Ridge Vent has a published net free ventilation area (NFVA) of 20 in / lineal foot. 4.9 Cobra® Hip Vent is a plastic, low -profile attic hip vent with filter for use in shingle roof systems. Theproduct, only for use on hips, measures nominal 11.4-inch wide supplied in 48-inch long sections, and issuppliedwithcorrosionresistant1%-inch coil nails. Cobra® Hip Vent has a published net free ventilation area (NFVA) of 9 in / lineal foot. 4.10 Cobra® IntakePro'" Rooftop Intake Vent is constructed from a woven plastic material being pressed to form the molded shape. A woven fabric material is utilized on the top, bottom and front, below the vent channel of the mold. The vent is configured into a roll 2out form. Cobra® IntakePro"* Rooftop Intake Vent has a published net free ventilation area (NFVA) of 9 in / lineal foot. 5. LIMITATIONS: 5.1 This is a building code evaluation. Neither TrinityJERD no Robert Nieminen, P.E. are, in any way, theDesignerofRecordforanyprojectonwhichthisEvaluationReport, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. Evaluation Report 01506.02.06-R14 Exterior Research and Design, I.I.C. FL6267-R14 Certificate of Authorization #9G503 6EDITION (2017j FBC NON-HVHZ EyARevision 14: 09/25/2017 GAF Roof VentilationProducts; (800) 766-3411 66-3411 Page3of 12 5.3 5.4 5.5 INITYJERD Minimum Slope Product 2:12Cobra" Exhaust Vent Cobra® Rigid Vent 3"" 3:12 Cobra® Rigid Vent 3`_- 9" 3:12 Cobra" Snow Country'" 3:12 Cobra" Snow Country Advanced'" 3:12 Cobra" Snow Country Advanced'" - 9" 3:12 Cobra® RidgeRunner" TruSlate" Ridge Vent 5: 12 12 Min. 3:12 to max. 12:12Cobra" Hip Vent Cobra- IntakePro- Rooftop Intake Vent 4:12 Unless otherwise determined through use of performance levels in Section 5.5, the maximum mean roof height for Cobra" Exhaust Vent, Cobra® Rigid Vent 3, Cobra" Rigid Vent 3 — 9", Cobra" Snow Country'", Cobra" Snow Country Advanced^', Cobra" Snow Country Advanced— — 9", Cobra" RidgeRunner", TruSlate" Ridge Vent, Cobra" Hip Vent and Cobra" IntakeProl Rooftop Intake Vent shall be 33 ft. Maximum Allowable Design Pressures: The following performance levels may be utilized for projects where the maximum mean roof height exceeds 33 ft. The Allowable Design Pressure shall meet or exceedcriticaldesignpressuredeterminedbyaqualifieddesignprofessionalinaccordancewithFBCChapter16. No rational analysis is permitted. Allowable Design Substrate: Product Pressure (psf) Min. 7/16-inch plywood Cobra" Exhaust Vent (nail gun version) 150 Min. 7/16-inch plywood Cobra" Exhaust Vent (hand nail version) 180 Min. 7/16-inch plywood Cobra® Rigid Vent 3T", Rigid Vent 3T." - 9", Snow 215 Country"', Snow Country Advanced— and Snow Country Advanced" - 9" 180 Min. 7/16-inch OSB or Cobra" RidgeRunner" plywood 190 Min. 7/16-inch plywood TruSlate" Ridge Vent Min. 7/16-inch plywood Cobra" Hip Vent 205 Min. 7/16-inch plywood Cobra" IntakeProT" Rooftop Intake Vent 175 5.5.1 Allowable Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FBC 1609 for determination of design wind loads. 5.6 Installation shall result in minimum net free ventilation area requirements set forth in FBC Sections1203.2. When more than one level of roof ridge existing over a single attic space, use ridge vents only at the high ridge. Evaluation Report 01506.02.06-R14 Exterior Research and Design, LLC. FL6267-R14 Certificate ofAuthorization #9503 6- EDITION (2017) FBC NON-HVHZ EVALUATION Revision 14: 09/ZS/2017GAFRoofVentilationProducts; (800) 766-3411 Page 4 of 12 TRINITY IERD 6. INSTALLATION: 6.1 GAF Roof Ventilation Products shall be installed in accordance with GAF published installation requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 COBRA® EXHAUST VENT: I 6.2.1 Chalk a cut -line 1-inch off each side of the ridge and cut a slot along the apex of the roof measuring 2 Inch for truss construction) or 3%2-inch (for ridge pole construction). The slot should terminate 6-inches from each end and 12-inches from hip intersections or chimneys. Cut only the sheathing; do not cut trusses. Figure A. 6.2.2 Unroll the vent along the entire length of the ridge, covering uncut 6-inch sheathing area on both ends. Shorter lengths can be joined by caulking and butting the ends. Figure B. 6.2.3 Apply a bead of polyurethane roof sealant to the underside of the entire perimeter of the vent and nailwithmin. 2%2-inch galvanized roofing nails at each corner and 10-inch o.c. Do not use excessive roof cement, as itmay result in shingle blistering. 6.2.4 Apply a bead of polyurethane roof sealant in the shape of a "C" to the underside of the entire perimeter of the cap shingles, and install cap shingles directly over the vent using Smart Nails' or 1%-inch corrosion resistant coil nails (supplied with the vent). Figure C. Do not use excessive roof cement, as it may result in shingle blistering. 6.2.5 Cobra® haust Vent (hand nail version) and Cobra® Exhaust Vent (nail gun version) have a %-inch or Ex 5/8-inch nominal thickness, respectively, to facilitate ventilation. Care shall be taken not to crush or compact the product during installation. Figure D. Hand -Nail Version Nail Gun Version Evaluation Report 01506.02.06-1114 Exterior Research and Design, LLC. FL6267-R14 Certijtcate ofAuthorization #9503 a EDITION (2017) FBC NON-HVHZ EVALUATION Revision 14 09/25/2017GAFRoofVentilationProducts; (900) 766-3411 Page 5 of 12 NiNITY 1ERD, 6.3 COBRA®RIGID VENT 3"", RIGID VENT 310' - 9", SNOW COUNTRY—, SNOW COUNTRY ADVANCED""" AND SNOW COUNTRY ADVANCED'"" - 9": 6.3.1 6.3.2 6.3.3 6.3.4 6.3.5 6.3.6 6.3.7 Mark -off and cut the slot opening as follows, ensuring that the ends of the opening stop at least 6-inch from any end walls and at least 12-inch from hip and ridge intersections or chimneys. No Ridge Board: Cut a 7/8-inch opening on each side of the ridge (Figure A). With Ridge Board: Cut a 1-5/8-inch opening on each side of the ridge (Figure B). Sealant: Apply a bead of silicone caulking or roof cement to the underside of the outer Dame among UUMedgesandatexposedends, ensuring the outside edges where the vent meets the shingles are sealed with the caulk or flashing cement. Vent Placement: Starting at one end of the slot, place, center and conform the Cobra® rigid vent over the slot with the vent firmly against the roof surface, ensuring the vent extends past the slot opening by at least 6-inch. Fasteners: For Cobra® Rigid Vent 3—, Cobra® Rigid Vent 3— - 9", Cobra® Snow Country Advanced— and Cobra" Snow Country Advanced'" - 9" only, use the 3-inch corrosion resistant ring shank nails (included). For Cobra® Snow CountryTM, use corrosion resistant nails at least 3-inch or longer. Nails must always penetrate through plywood decks or at least %-inch into wood planks. NOTE: GAF recommends 3-inch corrosion resistant ring shank nails for increased uplift resistance. Spacing: Attach the vent section through the pre -molded nailing holes located at 3, 12, 24, 36 and 45-inch from the start of each 48-inch vent piece. Joints: Apply the subsequent CobraO rigid vent sections over the length of the ridge using the overlap/underlap tabs. Ridge Shingles: Install ridge shingles in accordance with shingle manufacturer's published installation instructions, using corrosion resistant nails detailed in 6.3.4. A nail line is inscribed on top of the Cobra° rigid vent to serve as a guide. Evaluation Report o1506.02.06-1114 Exterior Research and Design, U.C. FL6267-1114 Certificate ofAuthorhadon #9503 6Tn EDITION (2017) FBC NON-HVHZ EVALUATION Revision 14: 09/25/2017GAFRoofVentilationProducts; (800) 766-3411 Page 6 of 12 TRINITY I ERD 6.4 COBRA® RIDGERUNNER® 6.4.1 Cut slot per 6.3.1. 6.4.2 Tear a 1-foot section to be used as a template for laying the vent out (Figure E-G) and center the template/ locator over the ridge cap shingles at the beginning of the vent slot. Note the location of the baffle (Figure H). Make sure to do this at both ends of the installation. 6.4.3 O Measure the distance from the edge of the roof slot to the exterior baffle (D). Establish a chalk line along one side of the ridge (Figure I). Unroll the vent and use the included 1-3/4-inch pneumatic corrosion resistant roofing nails to attach the first side of the ridge vent with the exterior of the baffle aligned with the chalk line (Figure J). Proceed with using the V interval EasyTear— system to custom size the vent to the appropriate length. If the EasyTear— system can not be utilized, use a utility knife to size the vent. Nail gun targets are embossed on the part as a guide for property attaching vent to the roof. The vent should be fastened on 6-inch centers (Figure K). Exterior Research and Design, LLC Evaluation Report 01506.02.06-R14 6'" EDITION (2017) FBC NON-HVHZ EVALUATION FL21 Certificate o/authorizotionu95o3 Revision 14: 09/25/20/2017GAFRoofVentilationProducts; (900) 766-3411 Page 7 of 12 f TRINITY 1 ERD 6.4.4 NOTE: When fastening the vent and cap shingles, be sure that the included 1 3/4-inch corrosion resistant coil nails completely penetrate plywood or provide at least 3/4-inch penetration into wood planks. In the case they do not, you must use alternate corrosion resistant nails that provide the required penetration. Proceed with attaching the other side of the vent. When beginning to nail down the second side, do NOT begin at the end; begin between the first and second one -foot sections and then return to fasten the first one -foot section. This will allow for proper fit. 6.4.5 Install ridge shingles in accordance with shingle manufacturer's published installation instructions, using the nail -lines on top of the ridge vent for proper lapping. 6.5 TRUSLATE® RIDGE VENT:. 6.5.1 DO NOT use on hips. 6.5.2 Intall TruSlate® Ridge Vent before installing the field slates. 6.5.3 After determining the total length of TruSlate® Ridge Vent required (for proper ventilation), determine the necessary slot opening. Mark -off and cut the slot opening, ensuring the ends of the opening stop at least 6-inch from any end walls and at least 12-inch from hip and ridge intersections or chimneys. Roofs without a ridge board: Cut a 7/8-inch opening along the ridge on each side (Figure A). Roofs with a ridge board: Cut a 1-5/8-inch opening along the ridge on each side (Figure B). 6.5.4 6.5.5 6.5.6 6.5.7 Fig. A Fig. B 41 m )JW JT9 (41 m>rd 22mm)7/9 7/8"(22mm) \i/ 311i (82 mm) With Ridge Board 13/4" (44 mm) No Ridge Board Install an 18-inch wide section of ASTM D1970 self -adhering leak barrier (holding Florida Statewide Product Approval or Approved on a local Basis) from the edge of the ridge slot extending down towards the roof deck on both side of the slot. Place the TruSlate® Ridge Vent over the ridge slot, "peaked" and centered over the ridge slot, and attach using minimum 3-inch long corrosion resistant ring -shank nails through the pre -molded nail holes on the vent, located 3-inch from the ends and 9-inch o.c. Fasteners shall penetrate through plywood decks or embed minimum'/ -inch into wood plank decks. Continue over the length of the ridge, utilizing the male/female connectors to connect units. Ensure the finished ends include the pre -molded end caps. Cover all exposed nail heads on the vent with silicone caulk. Intall a bead of exterior grade silicone sealant at the downslope leading edges of the ridge vent, at the junction of the leading edge and the leak -barrier below. Install the top course of TruSlateO field slates, UnderBlockl* UV & Moisture Barrier and TruSlate® trim slates in accordance with GAF published installation instructions. Intall TruSlate® trim slates with 10-inch exposure using minimum 1-5/8-inch long deck screws through pre -drilled holes, through the ridge vent to engage the wood deck. Exterior Research and Design, LLC. Evaluation Report 01506.02.06-R14 Certificate ofAuthorization #9503 6EDmON (2017) FSC NON-HVHZ EVALUATION F1.6267-1114 GAF Roof Ventilation Products; (800) 766-3411 Revision 14: 09/25/2017 Page 8 of 12 J TRINITY ERD 6.6 COBRA® HIP VENT 6.6.1 The roof deck shall consist of minimum of 7/16 inch thick plywood or OSB wood structural panels. Use only on roofs with slopes between 3:12 and 12:12. Install only on hips. Do not install Cobra® Hip Vent on ridges. 6.6.2 Sequencing: If ridge ventilation will be installed, always install the ridge vent to the end of the ridge before installing Cobra® Hip Vent. 6.6.3 Hip Air Slot: Determine the number of Cobra' Hip Vent sections needed for proper ventilation and thelocationforcutsintheroofhip. Cobra Hip Vent is installed over a 2Y2 inch wide slot opening centered on the hip beginning at 12 inches below the top of the hip and extending 36 inches down the hip for every 4footsectionofCobraHipVentneeded. Leave 12 inches of the hip uncut after each 36 inch opening, and the lowest opening must stop at the mid -point of the hip and more than 24 inches in from the exterior warm wall. Wider openings and slots below the midpoint of the hip will not improve ventilation and must be avoided. Cut away the shingles first with a roofing knife, and then cut the deck with a circular saw. The saw should be adjusted so that the rafters or trusses are not cut. Note: The roof decking must be re -nailed to the rafter at the edge closest to the hip to compensate for the nails removed when the hip slot was cut. Ridge Air Slots Hip Ndpolnt I1 II I I 000, I Slot length nearest O6G . i midpoint may wry o IJo`o I Deck I Eave I IMust be at least 20 1610 mm) from the warm wall Evaluation Report 01506.02.06R14 Exterior Research and Design, LLC. FL6267-R14 6' EDITION (2017) FBC NON-HVHZ EVALUATION CertificateofAuthorizationit9503Revision14: 09/25/2017 GAF RoofVentilationProducts; (800) 766-3411 Page 9 of 12 6.6.4 Sealant: Seal all cut -edges of the asphalt shingles to the roof sheathing along all sides of the hip air slot openings, using a bead of ASTM C920 polyurethane sealant, to prevent water infiltration. 6.65 Orientation: Always install Cobra® Hip Vent with the "Towards Peak" arrows on the top surface of the vent pointing up towards the peak of the roof. 6.6.6 Attachment: Cobra* Hip Vent is fastened to the deck starting at the bottom of the hip ana men up dwng the entire length of the hip (this includes un-cut portions of the hip). Fasten Cobra Hip Vent to the deck with the included 1%-inch inch long collated galvanized steel roofing nails, or longer corrosion resistant roofing fasteners, to achieve penetration through plywood or OSB decks or minimum 3/4-inch embedmentintowoodplanks. Attach the Cobra® Hip Vent section through the pre -marked 6-inch increment nail to rgets. 6.6.7 Joints & Terminations: Apply the subsequent Cobra® Hip Vent sections over the length of the hip using the overlap/underlap tabs. For roofs with ridge vents, lengths of the hip vent must be butted tightly tosectionsofridgeventsandinstalla3inchby12-inch strip of self -adhering leak barrier over ail junctions. For roofs without ridge vents, sections of hip vent from adjacent hip runs must be mitered together tightly where they intersect and install a 3 inch by 12-inch strip of self -adhering leak barrier over all junctions. Refer to GAF published installation instruction for details. 6.6.8 Ridge Shingles: Cobra Hip Vent is then covered with ridge cap shingles and this entire assembly is nailed to the sheathing with the included 1%-inch inch long collated galvanized steel roofing nails. Depending onthefieldandridgecapshinglesused, longer length corrosion resistant fasteners may be necessary. TheridgecapshinglesareinstalledpertheshinglemanufacturersinstructionsandFloridaProductApproval, with a minimum of two nails per shingle and a shingle to shingle nail spacing of 8 inches on center or less. Refer to the shingle manufacturers Florida Product Approval for ridge cap shingle fastening and sealing requirements. Do not overdrive the nails or crush/compact the product during installation. 6 7 COBRA®1NTAKEPRO"" R06FTOP INTAKE VENT 6.7.1 The roof deck shall consist of minimum of 7/16 inch thick plywood or OSB wood structural panels Use only on roofs with minimum slope of 4:12. Install only on eave edges of the roof. 6.7.2 Determine the length of Cobra® IntakeProTM Rooftop intake Vent sections needed for proper ventilationandthelocationforcutsneartheroofeaveedge. Install a metal drip edge at the eave of the roof. Measure up 6 and 7 inches up from the edge of the metal drip edge and strike chalk lines parallel to theeaveoftheroof. Cut a 1 inch wide air slot opening along the chalk lines, stopping a minimum of 12" (305mm) from rake/gable edges, side/end walls, and hip intersections, and stopping a minimum of 24" (610mm) from the center of valley intersections. The saw should be adjusted so that the rafters or trusses are not cut. Evaluation Report 01506.02.06-R14 Exterior Research and Design, I.M. FL6267-R24 Certificate ofAuthorization #9503 6G F Roof Ventilationon NON-HVHZ EVALUATION Revision 14: 09/25/2017GAFRoofVentilationProducts; (800) 766-3411 Page 10 of 12 4 RIN ffy ERD Note: After cutting the air slot, clear all debris blocking access into the attic space. Be sure to flatten attic insulation near the air slot to allow for proper intake airflow near the air slot. Attic baffles may be used to help prevent insulation from blocking intake airflow into the attic space. 6.7.3 Install a minimum 18 inch (457mm) wide FBC Approved peel -and -stick leak barrier down to the roof deck. Align peel -and -stick leak barrier flush to the edge of the roof on top of the drip edge metal. Use a sharp utility knife to cut the leak barrier, re -opening the 1 inch (25 mm) air slot that was previously cut in the deck. 6.7.4 Each roll of Cobra® IntakeProl Rooftop Intake Vent comes with two pieces of end cap fabric. To begin the vent run, place one piece of end cap fabric overhanging halfway over the rake/gable edge and parallel to the eave drip edge. Fasten the fabric to the roof deck using two roofing nails, one high and one low. If necessary, a piece of FBC Approved peel -and -stick leak barrier can be used in lieu of end cap fabric. 6.7.5 With the pre -marked dotted nail line and GAF logo facing up toward the sky, position the vent on top of the fabric end cap and flush to the rake/gable edge and eave drip edge. The front venting face of the vent should be flush with the drip edge metal below. Using the included 1-3/4 inch (44 mm) pneumatic coil nails, fasten the vent every 6 inches (152 mm) along the pre -marked nail line and fasten every 12 inches 305 mm), approximately 1-1/2 inches (38 mm) down from the up -slope edge of the vent. Do NOT nail within 1 inch (25 mm) from the side, top, or bottom edges of the vent. 6.7.6 Continue installing vent toward the opposite gable/rake edge or termination point. When installing multiple rolls, adjoin the rolls by butting them tightly together. There should be no gap between adjoining sections. The vent must always extend a minimum of 12 inches (305 mm) past any air slots. Miter cut the vent at any valley and hip intersections, ensuring the vent sections are butted tightly together. For terminations at gable and rake edges, cover the end of the vent run using the included fabric end cap in the same manner as the start of the vent run. 6.7.7 Install FBC Approved peel -and -stick leak barrier completely covering the top of the vent and extending from the eave edge to a minimum of 24 inches (610 mm) in from the building's warm wall. The leak barrier should not overhang the vent. Install rake drip edge if necessary. r,mcaaL,r eix a= r Is'Ii5)tanlxWe#bafCJ1 [gytBaa1 j 4 l` ice m¢.av as musramaamwnnna lrL (30i mnlM1anNNga`izodgk suN/¢nOmYt aMKpNMnxCmncmtlliaVII.9aaawnno d2c'16I6mNlranvaN mtru.Rlaa 1 cai as.+Rml.mwuxa 5``j, /a , a'ilslmmlW4.ameE9ea¢"V emetx 1.;\ Y/') PJ u9ncroYEmxa a-wa no^ lavhop 7taF _ van ma wtaaz wowmrnwsY+emnroptYe mFw. 6.7.8 Begin instailing the shingle starter course. The starter course and first course of field shingles should overhang the front edge of the Cobra® IntakePro` Rooftop Intake Vent by 1/4 — 3/4 inches (6 —19 mm) to provide a drip edge. Using the included 1-3/4 inch (44 mm) pneumatic coil nails, fasten the starter stripandfieldshinglesaspermanufacturer's installation instructions. Ensure the field shingles are not fastened into the open air intake slot below. Evaluation Report 01506.02.06-R14 Exterior Research and Design, LLC. FBC NON-HVHZ EVALUATION FL6267-R14 Certijicute ofAuthorisation A9503 6EDITION (2017 Revision 14: 09/25/2017 GAFRoofVentilationProducts; (800) %6-3411 Page 11 of 12 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 8. MANUFACTURING PLANTS: Acworth, GA Cumming, GA Enka, NC 9. QUALITY ASSURANCE ENTITY: UL, LLC. — QUA9625; (847) 664-3281 END OF EVALUATION REPORT - Evaluation Report 01506.02.06-1114 Exterior Research and Design, LLC. FL6267-I114 Certif8ote of Authorization #9503 67 EDITION.(2017) FBC NON-HVH2 EVALUATION 14: 09/2iison5/2017 GAF Roof Ventilation products; (800) 766-3411 Revpage 5 of 12 INSPECTION SEQUENCE BP# 18-4295 ADDRESS: 2511 Park Avenue BUILDING PERMIT Min Max Inspection Descri tion Footer / Setback Stemwall Slab / Mono Slab Lintel / Tie Beam / Fill / Down Cell Sheathing — Walls Sheathing — Roof 10 Roof Dry In Frame Insulation Rough Firewall Screw Pattern Drywall / Sheetrock Lath Inspection Building Ceiling Air Barrier Insulation Roof (Com'l) Building Ceiling Grid 1000 Final Roof Final Stucco / Siding Final Insulation Final Firewall Final Door Final Window Final Utility Building Final Screen Structure Final Pool Screen Enclosure Pre -Demo Final Demo Final Single Family Residence Final Commercial — Final Commercial — Addition / Alteration Final Commercial — Change of Use Final Building (Other) ELECTRLCALPERMIT ` e Min Max Inspection Descril2tion Electric Underground Footer / Slab Steel Bond Electric Ceiling Rough Electric Wall Rough Electric Rough Pre -Power Final Temporary Pole Electric Final RMIAPI, 1 G '.,: 10 - , Min Max Ins ection Descri tion Rough Plumb Plumbing Underground Plumbing 2"d Rough Plumbing Tubset Plumbing Sewer Plumbing Grease Trap Rough Plumbing Steam / Chill Water Rough Plumbing Final M ci A,icaL PEIuvIIT I _ g F Min Max Inspection Description Mechanical Rough Mechanical Fire Damper Framing Mechanical Ceiling Rough Mechanical Fire Damper Annular Space Mechanical Insulation Wrap Mechanical Fire Damper Angle Light / Water Test Ck Welds Mechanical Grease Duct Wrap Mechanical Final REVISED: June 2014