Loading...
3414 Whippoorwill Ct - E18-004299 - GENERATORJob Address: 3414 WHIPPOORWILL CT Parcel ID: 07-20-31-512-0000-0130 v 0_21_---- rNdy PERMIT APPLICATION Application No: I b — 14 o- 1 Documented Construction Value: $ 7,400 Historic District: Yes El No Residential Q Commercial Type of Work: New Addition X Alteration Repair Demo Change of Use Move Description of Work: INSTALL 22KW GENERATOR WITH 200 AMP AUTOMATIC TRANSFER SWITCH Plan Review Contact Person: NAN HOLMES Phone: 407-468-1010 Fax: Title: PERMIT COURIER Email: NANHOLMESPERMITS@GMAIL.COM Property Owner Information Name ROBERT GOULD Phone: Street: '3414 WHIPPOORWILL CT Resident of property?: City; State Zip: $AWORD, FL 32771 Contractor Information Name Walter E Southard Jr for Home Management Systems, LLC Phone: 407-448-7955 Street: 2429 DEERMEADOW DR City, State Zip: APOPKA, FL 32703 Name: Street: City, St, Zip: Bonding Company: Address: Fax: YES State License No.: EC13001390 Architect/Engineer Information Phone: Fax: E-mail: Mortgage Lender: Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT . Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: 6"' Edition (2017) Florida Building Code NOTICE: In addition to the requirements of this permit, there maybe additional restrictions applicable to this property that maybe found in the public records of this county, and there may he additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of [lie property of die requirements of Florida Lien Law, PS 713. The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time ofsubmittal_ The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value, credit will be applied to your permit fees when the permit is issued. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. A- Ujet: 17 14 Swriature ofOwrier/AgeiDate Sig CeofContractor/Agent Date Print Chwner/Agents Name Signature of Notay-State of Florida Date Owner/ Agent is Personally Known to Me or Produced ID Type of ID Name S MINDY HOLME9 of Florida k )a Commission # GG 205252 s Expires April9, 2022 Bonded TWU BudO Nrolary S*rk's Contractor/ Agent is )<— Personally Knowrt to Me or Produced ID Type of ID BELOW IS FOR OFFICE USE ONLY Permits Required: Building Electrical Mechanical Plumbing Gas Roof Construction Type: Occupancy Use: Total Sq Ft of B Min. Occupancy Load: New Construction: Electric - # of Amps: Fire Sprinkler Permit: Yes No # of Heads S IL-1 APPROVALS: " ZONING: Id.,2:! UTILITIES: ENGINEERING: Flood Zone: of Stories: Plumbing - # of Fixtures Fire Alarm Permit: Yes No WASTE WATER: FIRE: BUILDING: 'E II. 20 • tS COMMENTS: / 91161 j2! is o le u/%.1-hs fi c ig S,Fw//a Non a f a 2z w Mtn er'G 4-0i- 02c10 5-144 . .es s lye,rA Akei-S a,e-a m nal Wmcatl,.t L%/ afiJnt . f c Six--/ -r i...i,- if --,rta-.. SCPA Parcel View: 07-20-31-512-0000-0130 Property Record Card Parcel: 07-20-31-512-0000-0130 Property Address: 3414 WHIPPOORWILL CT SANFORD, FL 32771 Parcel Information Value Summary u j 2019 Working 2018 Certified Values Values Valuation Method Cost/Market i Cost/Market I Number of Buildings 1 1 Depreciated Bldg Value 170,060 $162,946 Depreciated EXFT Value Land Value (Market) 33,000 $33,000 Land Value Ag just/MarketValue" 203,060 $195,946 i Portability Adj j Save Our Homes Adj i 68 044 $63,707 Amendment 1 Adj 0 $0 P&G Adj 0 $0 j Assessed Value L--------... - - - ---- ------ 135,016 $132,239 Tax Amount without SOH: $2,897.12 2018 Tax Bill Amount $1,701.39 Tax Estimator Save Our Homes Savings: $1,195.73 Does NOT INCLUDE Non Ad Valorem Assessments al Description 13 POORWILL PG60 Taxes Description Date Book Page Amount Qualified i Vac/Imp i WARRANTY DEED 9/1/2001 04187 0982 33,,000 Yes Vacant WARRANTY DEED 9/1/2001 04187 0981 25,500 Yes Vacant WARRANTY DEED 8/1/1999 0.,70E 1754 294,500 No Vacant WARRANTY DEED 12/1/1997 03343 1158 320 000 No Vacant SPECIAL WARRANTY DEED 12/1/1992 z 02522 1923 351,000 No Vacant CERTIFICATE OF TITLE 11/1/1991 02356 1758 311,200 No Vacant Land i Units Price Land Valuei 1 `+ $33,000.00 ; $33,000 1/2 REQUMED !NSPECTION' SEQUIENCF; Bpff- i97- c4A':.R' m Mar luns2ecdoni Desclj2d Footer / Setback Stemwa-11 Fbundativi/Form Board..Survey Slab' /' -orio Slab - Prepour Lintel / Tie- Beam / Fill Down Ceff S -eaffiffig-L Walls - Sheathing -,L Roof RoofDry 1h Tra= insulation Rough In lFirewall S*drew Pattern Drywall / Sheetrock Lath Inspedtioh Final Solar Final Rum& /Siding FInsulationFinal Final Utility; Buifding- Final Door. I Final Wincfcy'w Find Screen.Room. Final.. Pool 8,'creen. Enclosure. Mobile Home Buildbag-Fina-1 Pre. -Demo Final Demo. Final Single Family: R-eddence, Final. Building(Other) Address: a tin Mn M= Insgi.eflon D scri flom Electric. Underground I Footet /' Slab Steel Bond Eleclxc Rough T.U.G. Pre -Power Final Electric Final min Igjrtft-l" HOSSRINB N=. I 97-911V. lmspe flon Descid2flom I -Plumbing Underground Plumbing Sewer Plumbing Tub- Set I Plumbing Final Dun Mechahical Rough Mech-am"cal. Final Max I Tms ec4oM.'Dqs'd%TrTp*fqTM' Gas Underground Gas Rough Oas-Fin!.al REVISED:* June 2014 Limitedt Power ofAttorney Date: p 8 I U To: Building Department From: Walter E Southard I hereby name and appoint Nan Holmes, Mindy Holmes and Raymond Holmes, a permit service for Home Management Systems LLC, to be my lawful attorney in fact to act for me and apply to So nLLO'fdfora "C'tr 10 r permit for work to be performed at a location described as: Address of Job) Owner of Property) CI A , RObe(-+ And to sign my name and do all things necessary to this appointment. Thank you for your assistance. Sincerely, kle f— ' 3-/(' Walter E Southard Jr State License Qualifier EC13001390 State of Florida County of The foregoing instrument was ac owledged before me as Walter E Southard Jr, who is personally known to m/0r who has produced identification o type of identification produced: Sworn to and subscribed before me this -) day of Sune , 20 I g pW. MARGARITA RIVERA Notary Public - State o1 Florida Notary S gnat r : • My Comm. Expires Sep 15, 2018 F ; Commission # FF 160012 F ..... Bonded through National Notary Assn. Grant Malo , Clerk Of The Circuit Court & Comptroller Seminole County FLInst #20181y20422 Book:9234 Page:1819; (1 PAGES) RCD: 10/18/2018 2:08:03 PM REC FEE $10.00 THIS INSTRUMENT PREPARED BY: Mind3 Ho)rfts Name: _ Home ManagementSystemsLkssAddre: 2429 DeermeadowDr Apopka, FL 32703 NOTICE OF COMMENCEMENT Permit Number: Parcel ID Number: 07-20-31-512-0000-0130 The undersigned hereby gives notice that improvement will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following Information isprovidedinthisNoticeofCommencement1. DESCRIPTION OF PROPERTY: (Legal description of the property and sheet address if available) 3414WHIPPOORWILL6T-- SANF-GRB, Fi=227711 OT 13 1NUIPROGRIA111 1 13 40 PG 69 2. G NtaA- PTIONa I rRO EM NT: nst 2Kois2and yGeneratoriSystemandATS3. OWNER INFORMATION OR LESSEE INFORMATION IF THE LESSEE CONTRACTED FOR THE IMPROVEMENT: Name and address: Robert B andTomoyoGould -3414 WHIPPOORWILL CT SANFORD, FL 32771 Interest in property: OWners Fee Simple Title Holder (if other than owner listed above) Home Management Systems 4 j 4. CONTRACTOR: Name:_ 2429 Deermeadow Dr Address: Apopka, FL 32703 5. SURETY ( if applicable, a copy of the payment bond is attached): Phone Number. Amount of Bond: LENDER: Name: Phone Number Address: 7. Persons within the State of Florida Designated by Owner upon whom notice or other' Io" cunients maybe served as provided bySection 713.13(1)(a)7., FloridaStatutes. Name: Phone Number. 8. In addition, Owner designates of to receive a copy of the Uenor's Notice as provided in Section 713.13(1)(b), Florida Statutes. Phone number. 9. Expiration Date of Notice of Commencement (The expiration Is 1 year from date of recording unless a different date is specified) WARNING TO OWNER. ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE' CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART I; SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOURPROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING W OR REC: INGYOURNOTICEOFCOMMENCEMENT. SAIAOY-ct Q . , n j t; Cos Art I Sig use or Owner or Lessee, or OwnersorLessee's (Print NameandProvide Signatory's totice) PnCL AuthorizedOrficadDhectodPartner/Manager) ' i. Stateof— flm Countyof The foregoing Instrument was acknowledged before me this zrld by name orp who has produced identification g snarement_ _-_---- of identification produced: µ " ""'• VANESSAMAIKER: 1 ', Notary Public — State ofFlorida Commission + GG 135325 y4 on f;.`• MyComm. EXpires Aug 16, 2021 day of 20 Who Is persona y knoiiun to me b OR Genstar Generator Services 1701 Perch Ln Sanford, FL US 407) 417-5553 Support@GenstarService.com Generator Services 407-417-5553 1701 Perch Lane Sanford, FL 32771 BILL TO SALES # 5375 Bob Gould DATE 07/31/2018 3414 Whippoorwill Ct Sanford, FL 32773 PREPARED BY Pamela 22 KW Generator with aluminum enclosure and (1) 200 Amp Automatic Transfer Switch. 1) Generac 22 KW generator with aluminum enclosure 1) Generac 200 Amp Non SE Automatic Transfer Switch 1) 12 V Starter Battery 1) Pre -cast concrete generator pad 1) PERMIT Up to (2) SMM All Related Electrical Materials and Supplies Scope of Work: Supply and Install Generator at designated site. Supply and install automatic transfer switch. Run conduit and wiring from Generator to ATS. Perform all electrical connections and Ground generator. Commission generator into service, provide operating instructions Perform Warranty Activation Warranty: Customer qualifies for a free 10 year extended warranty. Installation materials and work guarantee = 1 year Starter Battery warranty = 1 year Notes: Residence may be without power for 2-4 hours during installation. Proposal does not include repairing or replacing any landscaping, drywall or stucco damaged from installation. Gas line and supply installed and connected by others, The price on this estimate does not include gas hookup. Contracted Price = $7,400.00 . et 4 Thank you for your business. Questions please call 407-417- BALANCE DUE $0.00 5553 RECORD COPY Generator Installation Check List Per National Electrical Code, Article 702, Optional Standby Systems REVIEWED POR CODE COMPLIANCE Contractor: Main Line Electrical Contractors Permit # r— Property Address PLANS EXAMINER Bob Gould 3414 Whippoorwill Ct Sanford, FL 32773 _ \- ZdD • Lg DATE SERVICE SIZE 200 AMPS GENERATOR SIZE 22 KW GENERATOR 92 AMPS SWITCH TYPE AUTOMATIC 1!illl>•ll\ltllt 1 A LIU A ASf COD ASIOIV EDTOBEA AND NOT AS ER OR SET TECHNICAL MIT PREVENT THE BUILDING OFFICIAL FROM THEREAFTER REQUIRING A CORRECTION OF ERRORS IN PLANS, CONSTRUCTION OR VIOLATIONS OF THIS CODE National Electric Code Article: 702.5(B)(2)(a) Automatic Transfer Equipment The stand by source shall be capable of supplying the that is transferred by the automatic transfer equipment. Provide Load Calculations for review. (National Electrical Code 220.83 Existing Dwelling): Square Feet of Living Area 1896 Sq. Ft. Sq. Ft. of Living Area x 3va 5,688 2)Kitchen Special @ 1,500 3,000 Refrigerator @1,500 1,500 Laundry @1,500 1,500 Range @ 8,000 Water Heater 4,500 Dishwasher 1,440 Garbage Disposal 960 Clothes Dryer 5,000 1)AC/AHU @ 5000 5,000 Total 38,484 First 8K @ 1001/6 = 8,000 Remaining @ 40%= Remaining 30,484 *40% = 12,194 Total 20,194 20,194 /240 = 84 amps Provide Load shedding description and/or schematic. These items are not included in these calculations because the will be automatically load shed Note: Manual Transfer Equipment National Electric Code 702.5(B)(1) VILD yC SANFORD O A 1 RTD'! 1 8- 4299 Bob Gould 264 3414 Whippoorwill Ct Sanford, FL 32773 407) 688-1074 Existing Service 200 . r 0, 0 r enerator 8 rvi1ce 8cheplI atic Actual Configuration M:4 Vary} r r r Bob Gould 264 3414 Whippoorwill Ct Sanford, FL 32773 407) 688-1074 22 KW Genset with Non -SE ATS RXSC200A3 mounted inside garage Brkr Pnl ATS Garage Interior AC Gen Loc. Gen Pad 5" from Wall Gen flush with front of Brkr Pnl Q zsw. Avg. Product Review Rating: 5/5 based on 1 reviews -.read reviews) Genpad 31nch for Generac 9-22kW Air Cooled 2016 or Nervier Models 17852 A sturdy, permanent base for Generac Air Cooled Standby generators liContoured to look aesthetically pleasing Dimensions: 54' L x 31" W x 3" H Compatible with 9-22kW Generac Air Cooled 2016 or newerGenpad 3 Inch for Generac 9-22kW Air Cooled 2016 or Newer Models 17864 The GenPad is manufactured and designed to meet the engineering specifications for Generac air cooled generators. it. provides a sturdy,. permanent base for residential generators that won't shift over time. Each GenPad is made from a composite of high strength fibers and cement The GenPad also installs faster and cleaner than a poured concrete pad and gives a finished, professional look to your installation. The standard GenPad is ideal for most residential applications. it is contoured to look aesthetically pleasing. Compatible for Generac Air Cooled generators 9-22kW 2016 or newer. Dimensions: L54' x W31' x HT Weight: 189 lbs. Ships Free with a Generator or $90.00 Shipping fee Will Be Added INCLUDES: True Power" Electrical Technology Two Line LCD Multilingual Digital Evolution" Controller (English/Spanish/ French/Portuguese) Two Transfer Switch Options Available: 100 Amp, 16 Circuit Switch or 200 Amp Service Rated Smart Switch. See Page 4 for Details. Electronic Governor i System Status & Maintenance Interval LED Indicators Sound Attenuated Enclosure Flexible Fuel Line Connector Direct -To -Dirt Composite Mounting Pad Natural Gas or LP Gas Operation 5 Year Limited Warranty Capability to be installed within 18" (457 mm) of a building* FEATURES GENERAL GUARDIAN* SERIES Residential Standby Generators Air -Cooled Gas Engine Standby Power Rating Models G007036-0, G007037-0 (Aluminum - Bisque) - 16 kW 60 Hz Model G007035-0 (Aluminum - Bisque) - 16 kW 60 Hz Models G007039-0, G007038-0 (Aluminum - Bisque) - 20 kW 60 Hz Models G007043-1, G007042-1 (Aluminum - Bisque) - 22 kW 60 Hz G INNOVATIVE ENGINE DESIGN & RIGOROUS TESTING are at the heart ofGenerac's O success in providing the most reliable generators possible. Generac's G-force engine lineup offers added peace of mind and reliability for when you need it the most. The G-force series engines are purpose built and designed to handle the rigors of extended run times in high temperatures and extreme operating conditions. Q TRUE POWER'" ELECTRICAL TECHNOLOGY: Superior harmonics and sine wave form produce less than 5% Total Harmonic Distortion for utility quality power. This allows confident operation of sensitive electronic equipment and micro -chip based appliances, such as variable speed HVAC systems. O TEST CRITERIA: J PROTOTYPE TESTED V NEMA MG1-22 EVALUATION v' SYSTEM TORSIONAL TESTED V MOTOR STARTING ABILITY K LISTED Note: CUL certification only applies to unbundled units and units packaged with limited circuit switches. Units packaged with the Smart Switch are UL cedilied in the USA only. Only iflocated away from doors, windows and fresh air intakes, and unlessotherwise directed by local codes - SOLID -STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION: This state-of-the-art power maximizing regulation system is standard on all Generac models. tt provides optimized FAST RESPONSE to changing load conditions and MAXIMUM MOTOR STARTING CAPABILITY by electronically torque -matching the surge loads to the engine. Digital voltage regulation at y 1%. SINGLE SOURCE SERVICE RESPONSE from Generac's extensive dealer network provides parts and service know-how for the entire unit, from the engine to the smallest electronic component. O GENERAC TRANSFER SWITCHES: Long life and reliability are synonymous with GENERAC POWER SYSTEMS. One reason for this confidence is that the GENERAC product line includes its own transfer systems and controls for total system compatibility. LLJ GENERAC rypl73ss 6 Mobile 1PROMISE r¢ 4RRRM r IIIrC m fir V5.s4sea :mn Worts 46 16/20/22 kW features and benefits Engine Generac G-Force design Maximizes engine "breathing" for increased fuel efficiency. Plateau honed cylinder walls and plasma moly rings helps the engine run cooler, reducing oil consumption resulting in longer engine life. Spiny-lok" cast iron cylinder walls Rigid construction and added durability provide long engine life. Electronic ignition/spark advance These features combine to assure smooth, quick starting every time. Full pressure lubrication system Pressurized lubrication to all vital bearings means better performance, less maintenance and longer engine life. Now featur- ing up to a 2 year/200 hour oil change interval. Low oil pressure shutdown system Shutdown protection prevents catastrophic engine damage due to low oil. High temperature shutdown Prevents damage due to overheating. Generator Revolving field Skewed stator Displaced phase excitation Automatic voltage regulation UL 2200 listed Allows for a smaller, light weight unit that operates 25% more efficiently than a revolving armature generator. Produces a smooth output waveform for compatibility with electronic equipment. Maximizes motor starting capability. Regulates the output voltage to ±1 % prevents damaging voltage spikes. For your safety. Transfer Switch (if applicable) Fully automatic Transfers your vital electrical loads to the energized source of power. NEMA 3R Can be installed inside or outside for maximum flexibility. Remote mounting Mounts near your existing distribution panel for simple, low-cost installation. Evolution" Controls Auto/Manual/Off illuminated buttons Selects the operating mode and provides easy, at -a -glance status indication in any condition. Two-line LCD multilingual display Provides homeowners easily visible logs of history, maintenance and events up to 50 occurrences. Sealed, raised buttons Smooth, weather -resistant user interface for programming and operations. Utility voltage sensing Constantly monitors utility voltage, setpoints 65% dropout, 80% pick-up, of standard voltage. Generator voltage sensing Constantly monitors generator voltage to ensure the cleanest power delivered to the home. Utility interrupt delay Prevents nuisance start-ups of the engine, adjustable 2-1500 seconds from the factory default setting of 5 seconds by a qualified dealer. Engine warm-up Ensures engine is ready to assume the load, setpoint approximately 5 seconds. Engine cool -down Allows engine to cool prior to shutdown, setpoint approximately 1 minute. Programmable exercise Operates engine to prevent oil seal drying and damage between power outages by running the generator for 5 minutes every other week. Also offers a selectable setting for weekly or monthly operation providing flexibility and potentially lower fuel costs to the owner. Smart battery charger Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature. Compatible with lead acid and AGM -style batteries. Main line circuit breaker Protects generator from overload. Electronic governor Maintains constant 60 Hz frequency. Unit SAE weather protective enclosure Sound attenuated enclosures ensure quiet operation and protection against mother nature, withstanding winds up to 150 mph. Hinged key locking roof panel for security. Lift -out front for easy access to all routine maintenance items. Electrostat- ically applied textured epoxy paint for added durability. Enclosed critical grade muffler Quiet, critical grade muffler is mounted inside the unit to prevent injuries. Small, compact, attractive Makes for an easy, eye appealing installation, as close as 18; away from a building. Installation System 1 ft (305 mm) flexible fuel line connector Absorbs any generator vibration when connected to rigid pipe. Direct -to -dirt composite mounting pad Complex lattice design prevents settling or sinking of the generator system. Integral sediment trap Prevents particles and moisture from entering the fuel regulator and engine, prolonging engine life 16/20/22 kW specifications Generator G007035-0, G007036-0, G007038-0, G007039-0 G007042-1, G007043-1 Model 6007037-0 (16 li 20 kW) 22 W) Rated huoPCatymaximumConnowerapd000Wats*, 22i000 Rated Maximum Continuous Power Capacity (NG) 16,000 Watts' 18,000 Watts' 19-,500 Rated. Voltage .: " 24Q 240 '... 240 Rated Maximum Continuous Load Current —240 Volts (LP/NG) 66.6/66.6 83.3/75 91.6/81.3 Total Harmonic Distortion Less than 5% Li3ss thatCS% less fhan 5%. Main Line Circuit Breaker 70 Amp 100 Amp 100 Amp Phase Numberof Rotor Poles 2 2 2 Rated AC Froquency„ , - . _ _ 60 Hz ._ 60 Hz, _" 60Hz. _., Power Factor 1.0 1.0 1.0 Battery Requirement (not included) 12 Volts, Group 26R 540 CCA^Minimum or Group35AGM 650 CCA Minimum: Unit weight (lb/kg) 406/186 448/203 466/211 Dimensions, ( L xW x ti) rNmm 48 x 25x 29t121A638 x 732 Sound output in dB(A) at 23It (7 m) with generator operatingat normalload" 66 66 67 Sound output in dB(A) at 23 ft (7 m) with generator m Qwet Test _low speed exercise mode"' 58: 58 58 Exercise duration 5 min 5 min 5 min Engine Type ofEngine GENERAC G-Force 1000 Series Numbeot Cylinders Displacement 999 cc 999 cc 999 cc Cylinder Block Aluminum w! Cast Iron Sleeave Valve ArrangementOverhead Valve Overhead Valve Overhead Valve kjni6on System Solid state v1 Magneto "` Solid-state w/'Magneto Soh_d statewl Magneto Governor System Electronic Electronic Electronic Compression Ratio9.51 9 51 9(51 Starter 12 Vdc 12 Vdc 12 Vdc Oil Capacity Including Filter APProx 1.9 gV1.8 L ;Approx 1.9 gV1:8 L APprox 1.9 gV1.8 L Operating rpm 3,600 3,600 3,600 Fuel: Consumption ' . Natural, Gas w/hr(an°Jhr) 112 Load . :. 218 (617) - _ 2 l4 (5.78) 228 (6 46) . FUII: Load309 (8,i5) =:. 301_(8.52}; 327:(9 26) Liquid Propane fl37hr (gal/hr) [Imr] 1 2Load 91.6 (2.52} [9 53J , ` {86,(2.37)-[8:99J = 92 (2.53) [9.571 Ful)'Load ;. J 106.8 (2.94) [11.11J 129.6 (3.56).[13.481,. 142 (3.90) [14,77] Note: Fuel pipe must be sized for full load. Required tuel pressure to generator fuel inlet at allload ranges - 3.5-7` water column (7-13 mm mercury) for natural gas,10-12' water column (19-22 mm mercury) for lP gas. For Blu content, multiply tt3/hr x 2500 (LP) or ft3/hrx 1000 (NG). For Megajoule content, multiply ma/hr x 93.15 (LP) or mn/hr x 37.26 ING) Controls 2- Line Plain Text Multilingual LCD Display Simple user interface for ease of operation. Mode But[ ons.Aulo Aulomahc Start on Utility tailure. 7 day exerciser Manual Start with starter control, unit stays on. If utility fails, transfer to load takes place. S[ops dnit Power is removedConlrotaid rdlarger'shll operate. Ready to Run/Maintenance Messages .. Standard Engre Run Hours indication Standard Programmable start delay between 2-1500 seconds Standard (programmable by dealer only) Utility Vollagelos' sJRelumtoUtiffyAdjustable "{BrownoutSettmg) Fmm14017tV/140_=216V Future Set Capable Exerciser/Exercise Set Error Warning Standard RuNAlarrr(IMMaintenance Logs, 50 Events Each Engine Start Sequence Cyclic cranking:16 sec on, 7 vest (90 sec maximum duration). starte[Lock-out " Starlet can imi re-engageuntil 5 see after engtIlet as slopped _ SmartBattery Charger Standard ChargerFault/Missng AC Vdaming Standard:'' =: Low Batery/Battery Problem Protection and Battery Condition Indication StandardAulomabc Voltage_Regulabon wittt Over and Under Voitage Prolechon "'"_ ... Standard Under-Frequency/Dvedoad/ Stepper Overcurrent Protection Standard Safety 1`6sed/ Fuse:ProblemProtection : StaMaN` Automatic Low Oil Pressure/High Oil Temperature ShutdownStandard Overcra"nklOverspeeA (Q 72 Hz)(mm Sense. Loss Shutdown Stand High Engine Temperature Shutdown Standard Intem$t Faultnncoriea Wiring Protection = Standard. Common Exlemal Fault Capability Standard field Upgradable, Ejrmwar - Standard Sound levels are tom! from, thefront of are gnerds. S•amndlevels gre: from other sides ofthe gnerata may be higher dependirgon installalion paanelom Rating ? linfions-Shanty Applicaleia for supplying emergemyr ower for the duration W.- Nutif ty powrra:tW.. % overload capabity is a ailable to; !h's rating. (Ali radrgsinauudatce with 95657 4. (SJ'i46 a:d ir:No27 s'. 'Maximum Irlovaltairscivil csrenl ere subpc! toa1d IinitWd by s:ich tsir astual ;it•Um.r;le GonloI , an ienr t- znp; alore, a' f+ae. engine per and condition. etc. Maximum power muea^.s afxx;:3.5 perrc nt fan each 0--Cfeet (30.4.e melors) above %a level, a!d also will decree abroad,(1 perc t for ean. 6'C (10'n above 16'G (60'9. 16/20/22 kW Limited Circuits Switch Features 16 space, 24 circuit; breakers not included. Electrically operated, mechanically -held contacts for fast, positive connections o Rated for all classes of load, 100% equipment rated, both inductive and resistive. 2-pole, 250 VAC contactors. 30 millisecond transfer time. Dual coil design. Rated for both copper and aluminum conductors. Main contacts are silver plated or silver alloy to resist welding and sticking. NEMA/UL 3R aluminum outdoor enclosure allows for indoor or outdoor mounting flexibility. o Multi listed for use with 1" standard, tandem, GFCI and AFCI breakers from Siemens, Murray, Eaton and Square D for the most flexible and cost effec- tive install. Dimensions Height Width Hl H2 Wt W2 Depth in 26.75 30.1 10.5 13.5 6.91 mm 679.4 764.3 266.7 343.0 175.4 Wire Ranges Conductor Lug Neutral Lug Ground Lug 1/0-#14 2/0-#14 210-#14 Service Rated Smart Switch Features Includes Digital Power Management Technology standard (DPM). Intelligently manages up to four air conditioner loads with no additional hardware. Up to four more large (240 VAC) loads can be managed when used in conjunction with Smart Management Modules (SMMs). O Electrically operated, mechanically -held contacts for fast, clean connections. Rated for all classes of load: 100% equipment rated: both inductive and resis- tive. 2-pole, 250 VAC contactors. Service equipment rated, dual coil design. Rated for both aluminum and copper conductors. Main contacts are silver plated or silver alloy to resist welding and sticking. NEMANUL 3R aluminum outdoor enclosure allows for indoor or outdoor mount- ing flexibility. Dimensions 200 Amps 120/240,10 Open Transition Service Rated Height Width H1 H2 W1 W2 Depth in 26.75 30.1 10.5 13.5 6.91 mm 679.4 764.3 266.7 343.0 175.4 GENERACP switch options Model G007036-0 (16kW) No. of Poles 2 Current Rating (Amps) 100 Voltage Rating (VAC) 120240 10 Utility Voltage Monitor (Fixed)' Pica-up 80% Dropout 65% Return to Utility' approx.15 sec Exercises bi-weekly for5 minutes* t Standard UL Listed Standard - Total Circuits Available 24 Tandem BreakeiCapabihbes' 8 tandems - Circuit BreakerProtected Available RMS Symmetrical 10,000FaultCurrentQ250Volts Function of Evolution Controller Exercise can be set to weekly or monthly Model G007037-0 (16 kW)/GO07039-0 (20 kWY G007043-0 (22 kW) No of Poles' 2 Current Rating (Amps) 200 Voltage Rating (VAG) 120240, 10 _.. Utility Voltage Monitor (Fixed)' Pick-up 80% D,Qooul 6596 Return to Utility' approx, 13 sec Exercises bi-weekly for 5 minutes' Standard ULListed Standard Enclosure Type NEMA(UL 3R Circuit Breaker. Protected ` 22,000 Lug Range 250 MGM - #6 Function of Evolution Controller Exercise can be set to weeldy or monthly 16/20/22 kW GENERAL available accessories Model # Product Qescnpbort The Wi-Fi enabled LP fuel level monitor provides constant monitoring of the connected LP fuel tank. Mon- G007005 0 Wi Fi LP Fuel Level Monitor itoring the LP tanks fuel level is an important step in making sure your generator is ready to run during an unexpected powerfailure. Status alerts are available through afree application to notify when your LP tank is in need of a refill. Generac's Mobile Link allows you to check the status of your generator from anywhere that you have ac- G006463-4 Mobile Link- cess to an Internet connection from a PC or with any smart device. You will even be notified via e-mail or text message when a change in the generator's status occurs. Available in the U.S. only. G00581 90 26R Wet Cell Battery Every standby generator requires a battery to start the system. Generac offers the recommended 26R wet cell battery for use with all air-cooled standby product (excluding PowerPact®). G007101 0 Battery Pad WarmerThe pad warmerrests under thebattery. Recommended foruse if thetemperaturereguladyfalis below 0°F., NotnecessaryforusewithAGM -style batteries). G007102- 0 Oil Warmer Oil warmer slipsdirect) over the oil filter. Recommended for use if the temperature regularly falls below o° F. G005621- 0 Auxiliary Transfer Switch The auxiliary transfer switch contact kit allows the transfer switch to lock out a single large electrical load; Contact Kit You may not need. Not compatible with 50 amp pre -wired switches. Fascia Base Wrap Kit The fascia base wrap snaps together around the bottom of the new air cooled generators. This offers a G007027- 0 - Bisque Standard on 22 kW) sleek, contoured appearance as wellas offering protection from rodents and insects by covering the lifting, holes located in the base. If the generator enclosure is scratched or damaged, it is important to touch-up the paint to protect from G005703- 0 - Bisque Paint Kit future corrosion. The paint Idt includes the necessary paint to properly maintain or touch-up a generator " enclosure. G006485 0 Scheduled Maintenance Kit Generac's scheduled maintenance kits provide all the hardware necessary to perform complete routine maintenance on a Generac automatic standby generator. 0006873- 0 Smart Management Module Smart Management Nodules are used in conjunction with the Automatic Transfer Switch to increase its 50 Amps) pourer management capabilities. It provides additional power management flexibility not found in any other; power management system. dimensions & PCs Dimensions shown are approximate. Refer to installation manual for exact dimensions. DO NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES. P `" I LEFT SIDE VIEW k" 5" FROM VIEW Model UPC G007035- 0 696471070354 G007036- 0 696471070361 G007037- 0 696471070378 G007038- 0 696471070385 G007039- 0 696471070392 G007042- 0 696471070422 G007043- 0 696471070439 GE N E R AC' Generac Power Systems, Inc. • S45 W29290 HWY. 59, Waukesha, WI 53189 • generac.com s. 2017 Generac Power Systems; Inc. All rights reserved. All specifications are subject to change without notice. Part No. 10000000194-1`5; 3117 tAUNDARY SURVEY FOR Wa lerford ,Qua.li ty Hom es of: lk _f OE CRIPTION L 0 T 1, , 1'.',41PPOORWILL, A-CcORDING '0 THE PL'A T THEREOF A' RECORDED IN PLAT BOOK 40, PAGE 80 OF THE PIBLIC R1*GORLJS OF SEMINOLE COUNTY. FLORIDA. n Nr o h°3co1 40, N 89742' 00" E N 121. 5:_(D tL.S.3764) a a Li 543 F 5' DRAINAGE & UTQtiY EASEMENT r't._w? d---- r LEGEND w< I srss po 0' U M REC DENOTIS RECOVERED pj 44 ¢/ ° to U) y .,40vr. f W. 0C.M. CQNCRETE'WNUMENT 1.P, IRON PIPE. W W G) I Nb Q b+•`1•Wrsn I, Ot 0 O M IRON ROD' WC, NAIi AND CAP 1. O Lu f u Q Y a IG' 4' 1 Iv t colp J w R I OHT-•OF`-WAY -1 4'1LL s P.C. P0,lNT.OF CURVATURE t- rlaotED j n j,• 1 n F- o C.B. CONCRETE, BLOCK W . C , WOOD FRAKE „} taJ r..?,yC. , O $ • u. v000NC. REs. RESIDENCE CONCRETE t, V 00 f twria z! fi aD, ipri.s i I U) m co A.C. AIR' CONDITIONER L,S. LlCENSEt'SURVEYOR y 1 i O% g y' CDICE}Vr,Pp It4. 9 1 L.B. LICENSEE' BUSINESb a M) ofva W I Sg.J I 8 w ? fI I. TWS PROPERTY Lit IN iLOOO ZONE($) X PER TO{' FF.E.U.A. FLOOD INSURANCE RATE MAP, COMMUNITY -PANEL. NLA48ER(s) 1202 0045 DATEO Ayt9ve 1 10':DRAINAGE & UT1LItY EASEMENT d 5- i'---i--- I 2. DATA HAS NOT;8BEN FURNISKO TO THE SURVEYOR. 2!'q Y awo xCa.!1o72 sC TITLE3, UNDERGROUND, 1f006VEwENTS HAVE NOT OccN LOCATED, yy' 4. NOT VALID UNLESS'SEAIED WITH AN;CMSOSSED SEAL. REC.1/7'i•R, 89'.42' OO'' E 123. Pt SiB'I.R. 40' 5. 74S PROPERTY. Litt IN+SECl N I(S) '' T - IOWNSWP 20' SOUTH, RANGE 31. EAST,' tl.B.22 4) L. S.378t o rs0 SWAGGERTY LAND SURVEYINC. fNC. 1450 rnSTNER PLACE. SU,I fE 100 P, d1.. Boxy 23614r> P G. s p 2p ap ee tJA1034630o Aijy7)32Z3881I'