200 Starport Way - 08-000564 (2008) FIRE ALARMCITY OF SANFORD PERMIT APPLICATION Application # f 0 So _ 5(A Submittal Date: P o' C) Job Address: 200 STARPORT WAY Value of Work: $1,495 Parcel ID: 05-20-31-300-0010-4520 Zoning: Historic District: Description of Work: ADD 1-FACP, 1-DIALER,1-REMOTE ANNUNCIATOR Square Footage: Permit Type: Building Electrical Mechanical Plumbing Fire Sprinkler/Alarm Pool Sign Electrical: New Service — # of AMPS Addition/Alteration Change of Service Temporary Pole Mechanical: Residential Non -Residential Replacement New (Duct Layout & Energy Cale. Required) Plumbing/ New Commercial: # of Fixtures # of Water & Sewer Lines # of Gas Lines Plumbing/New Residential: # of Water Closets Plumbing Repair — Residential Commercial Occupancy Type: Residential Commercial )K Industrial Occupancy Use Group(s): Construction Type: # of Stories: # of Dwelling Units: Flood Zone: (FEMA form required) Property Owner: SANFORD ARPRT AUTH/CITY SANFORD Contractor: FIRETRONICS INC Address: 1 RED CLEVELAND BLVD STE 1200 Address: 1035 PINE HOLLOW POINT DR SANFORD FL 32773 ALTAMONTE SPRINGS FL, 32714 Phone: E-mail: Phone: 407-774-6900 State License Number: EF0000423 Bonding Company: Address: Architect/Engineer: Address: Mortgage Lender: Address: Phone: Fax: Plan Review Contact Person: MARK STEPHENSON Phone: 407-774-6900 EXT 128 Fax: 407-774-2074 E-mail:mstephenson@firetronics.com Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, and AIR CONDITIONERS, etc. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR- PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there maybe additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements ]a "ie.FS 713. Signature of Owner/Agent Date Signature of Contractor/Agent Date Print Owner/Agent's Name Signature of Notary -State of Florida . Date Owner/Agent is _ Produced ID APPROVALS: ZONING: Special Conditions: Rev 07.07 Personally Known to Me or UTIL: 1 D:Qn egi IN - fltsgA S Print Contractor/Agent's ame VA A167 Signature'f' otary-State of Florida Date tJcii ry public State of Florida r ® Linda Bean o` My Gommissio 672972 or F4°a Ex ices 071 12011 Contracto --_ erson y nown to Me or Produced ID FD: ENG: BLDG: 1 31 ,5 IRETRONICS, INC. FMTROMCS -EXTINGUISHERS,, INC. 1035 PINE HOLLOW POINT DR ALTAMONTE, SPRINGS, FL. 32714 PHONE (407) 774-6900 - FAX (407) 774-2074 illaw.1TWEIVIRTS-1 SUBMITTAL FOR STARPORT AVIATION 200 STARPORT WAY BUILDING #2 SANFORD OFFICE VlrANED r Fire Prev vDDiv. fev I FIRETRONICS1035PineHollowPointDr. Altamonte Springs, Fl. 32714 DATE 200 STARPORT WAY NEW FACP ADDITION X SUPERVISORY CURRENT STATUS: INO MANGE 0.004 AMPS (PANEL ONLY) 0 AMPS (NEW DEVICES) X 24 HOURS SUPERVISORY 711 > 5104 > DIALER PANEL= SK-4>1X.015=.01 0.135 AMPS (NEW DEVICES) TOTAL COMBINED AH REQUIRE 3.5903921 MINIMUM BATTERY AH REQUIRE 4.30847 SK-4 & SK-4E Fire Aiarrn Control Panel 4-zone fire protection at a price that won't burn, your budget. The SK-4 and SK-4E (SK 4/E) are four zone conventional fire alarm control panels (FACPs) that bring the latest in microprocessor technology to conventional, fire controls. The SK-4 is a 120.VAC FACP and the SK-4E is a 240 VAC FACP. These FACPs provide reliable fire signaling protection for small- to medium-sized commercial, industrial, and institutional buildings. For more information about the'SK-4/E system, or to locate your nearest source, please call 1-800-446-6444, or in' Minnesota, call 763-493-6435. Description Support for synchronization of The four zone SK-4/E is a 24 VDC„_ - standard ANSI audible signals and ADA compliant strobes per NFPA 72FACPthatprovidesfourClassB initiating device .circuits and two Class ' Selectable for System Sensor, I B notification appliance circuit (NAC).. Wheelock, and Gentex protocols Selective silence feature allows The SK-4/E NAC protocol includes the manual silence of horns while strobes ability to silence audible devices while continue to flash on the same NAC strobes continue to flash, using only a program for combinationtamper i single pair of wires. The SK-4/E is, also supervisory monitor and waterflow compatible with conventional input `"' alarm on one zone devices such as two- and four -wire- Silent or audible walk test operation smoke detectors, pull stations mode waterflow devices, tamper switches and Alarm verification selectable per zone other normally -open contact devices.. - Program each zone for supervisory or I Activation of a compatible smoke fire with separate red and yellow I detector or any normally -open fire LEDs alarm initiating device activates audible Disable switches provided per zone SK-4 9 and visual signaling devices, illuminates an indicating LED, sounds the piezo Program NACS for Silence inhibit Initiating Device Circuits (IDCs) sounder at the FACP, activates the '- Auto'`silence Operating Voltage: 22 VDC nominal y power -limitedFACPalarmrelay, and operates an Strobe synchronization Standby Current: 4 mA ? optional module used to notify aremote Temporal or steady signal Alarm Current: 15 mA min station or initiate an auxiliary control ". Silenceable or nonsilenceable Short-circuit Current: 40 mA max function, Disable Loop Resistance: 1000 max The SK-4/E is compatible with System Form C_alarm, trouble, and, _. - EOL Resistor: 4.7K Q, 1/2 watt Sensor@ 13 detectors providing . ; supervisoryrelays N Cs Signaling Current: 24 VDC advanced features such as drift 3A total usable current orm with. standard transformer or 5A compensation, maintenance alert, and 6A total usable current with optional total (2.5A per NAC) with additional., freeze warning. Automatic second transformer (PN SK-TRM24 optional transformer, power -limited synchronization of audio/visual devices or SK-TRM24E) EOL Resistor: 4.7K Q, 1/2 watt is provided, using three selections for. Optional dress panel (PN SK-DP2/4) Form C Relays manufacturer protocol. Types: Trouble, alarm, and ElectricalSpecifications supervisory Features SK- 4 Primary AC: 120 VAC @ 50/60, Contact Ratings: 2A @ 30 VAC, Four Style B (Class B) initiating Hz, 2.3A . resistive device circuits ( IDCs) SK-4E Primary AC: 240 VAC @ 50 Hz, Two Style Y (Class B) notification appliance circuit ( NAC) Wiring: 14AWG (2.0 mm2) with 600 V SLENT Optional module converts all IDCs insulation min KNI,G' and NACs to Class A (PN SK-CAC4) by l- toneyell S K-4 & S K-4 E Fire Control Panel Engineering Specifications The contractor shall provide a completely electrically supervised fire alarm control panel Silent Knight Model SK-4/E. The system shall contain a fire alarm control panel capable of operating and supervising smoke detection devices, alarm notification devices, and an on -board annunciator. It shall.,be `° compatible with a digital communicator accessory. The fire alarm control panel shall have a power limited supply, four Class B initiation circuits which shall accommodate heat detectors, smoke detectors, and manual pull stations. Smoke detection shall be achieved with either 2- or 4-wire detectors that are compatible with the system. The initiation inputs shall be programmable as 1) verification zones in which detectors are automatically reset one time before signaling an alarm condition; or 2) combination waterflow supervisory zones that allows the FACP to distinguish between an alarm switch (waterflow device) and a supervisory switch s y tamper) installed on the same circuit. The FACP shall have two 2.5 amp or 5 amp (with an additional optional standard transformer) programmable notification outputs. It shall have dedicated relays for alarm, trouble, and supervisory. It shall have two power outputs, one resettable and one non- resettable, each rated at 500 mA. The FACP shall have anon -board annunciator to indicate alarm, supervisory, trouble, and maintenance conditions. The annunciator must include LEDs for AC, GENERAL TROUBLE, ALARM SILENCE, WALK TEST, EARTH FAULT, AND LOW BATTERY. The annunciator shall also contain LEDs to annunciate fire alarms, troubles, supervisory, and maintenance by zone. The FACP must be fully operational from the annunciator and include buttons for ACKNOWLEDGE, ALARM, SILENCE, RESET, and WALK TEST. The annunciator must also have separate DISABLE switches for each zone and ' notification circuit.rr Electrical Specifications (cont) Installation SK-4XTM Auxiliary Output The SK-4/E can be surface mounted Transmitter Module. Provides a Resettable and non-resettable using two key slots at the top of,the supervised output for local energy Operating Voltage: 24 VDC nominal backbox and two additional 0.25" ; municipal box transmitter and alarm Current: 500 mA max, power -limited; diameter holes at the bottom, or semi- and trouble reverse polarity. total current for nonresettable power, flush mounted using the optional Trim SK-4XLMresettablepowerandtwoNACsmustRingP/N TR-1-R not exceed 6.OA (requires additional LED Interface Module. transformer) Approvals SK-XRM24 Battery NFPA 72; UL Listed;. 110 Volt Transformer 3-6A. Type: Sealed lead acid only CSFM 7165-0559: 145; Charging Circuit: 27.6 VDC @ 0.8A MEA 297-01-E-3 SK-XRM24E max normal flat charge Ordering Information 220 Volt Transformer 3-6A. Charging Capacity: 18 AH SK-4 SK-RZA4 Size: 7 AH max allowed in FACP. 120 VAC Four Zone Conventional Remote Annunciator. Larger batteries can housed FACPinanRBBaccessorycabinet SK4XZM Z R 1 M d 1CompatibleInitiatingandNAC .... SK-4E .;:. one a ay o u e. Devices 240 VAC Four Zone Conventional RBBSeeSKdocumentPN52612. FACP Remote Battery Box Accessory Mechanical Specifications Accessories Cabinet. Use if back up batteries are — CabinetCabinet Backbox Dimensions: SK-DP2/4 too large to fit into FACP cabinet. 14.5" W x 15" H x 3" D D P I All t th Dimensions: 16"W x 10"H x 6"D 36.83 W x 38.10 H x 7.62 D cm) Cabinet Door: 14.677" W x 15.342" H x 0.375" D 37:28 W x 38.97 H x 0.95 D cm) Cabinet Color: Red Telephone Requirements: FCC Part 15 and Part 68 approved Type of Jack: RJ31X (two required) ress one . ows access o e panel controls but restricts access to system wiring. SK-CAC4 Class A Convertor. Converts Style B Class B)1DCs to Style D (Class A) and Style B (Class B) NACs to StyleZ Class A) Digital Communicator Accessories 5104B Six -zone fire control communicator 5129 Four channel slave fire communicator" SILENT'[ This document is not intended to be used for installation purposes. We try to KNIGHT keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are byHransyweil subject to change without notice. For more information, contact Silent Knight 1550 Meridian Circle Suite 100, Maple Grove, Mn 55369-4927. Phone: ( 800) 328-0103, Fax: (763) 493-6475. MADE IN AMERICA FORM# 350305 Rev. C 12l06 Copyright © 2006 Silent Knight 3 1 speed, reliability i•ti yy value tio the company of digital communicns from As pioneers in digital fire technology, Silent Knight delivers superior systems at an outstanding value. Our 5104B Fire Control Communicator has become the industry standard by proving itself in years of field-tested operation. This six -zone fire control communicator provides fast, reliable digital communication of fire and trouble conditions. It transmits via ordinary phone lines - eliminating the need for expensive leased line arrangements. Use it as a stand-alone, or incorporate it into your existing system. Why spec any other digital communicator? Go with the industry standard the 5104E Fire Control Communicator from Silent Knight. For more information, please call 1-800-446-6444, or in Minnesota, call (763) 493-6435. Model 5104B the central station. If one of the Fire Control Communicator telephone lines faults for more than The Silent Knight Model 5104B is a six -zone fire control communicator providing digital fire reporting over ordinary telephone lines, eliminating the need for costly leased lines. It's UL 864 and NFPA 72 approved for monitoring local evacuation controls. As a stand-alone unit, it can be used to monitor: Sprinkler systems for waterflow, supervisory, and gate valve tamper conditions. Automatic fire detection systems for structures that are not required to have a fire alarm system but want property protection (e.g. to call the fire department after hours). Monitors dry contact alarms, trouble and supervisory outputs, then transmits a separate code for each. The Model 5104B is fully supervised. Its microprocessor constantly runs programs to monitor AC, standby battery, zone inputs and telephone line connections. If a fault condition is detected, it sounds a local trouble audible and reports the condition to 60 seconds, it will automatically switch to the other to report the failure. The communicator will signal activation, restoration and trouble conditions on any of six inputs. If an application requires a different input configuration, the individual input styles may be changed by using a Model 7181 Fire Zone Converter Module. The 7181 also allows use of two -wire type smoke detectors', instead of the normal four -wire contact type, for automatic fire detection applications. Features UL 864 Listed as an NFPA 72 Central Station or Remote Station protected premise unit. FM approved. Can be used as a stand-alone or as a Slave DACT. Six fully supervised inputs: one Class A (Style D) input, and five Class B (Style A) inputs. Downloadable for remote programming. Fuseless overload protection with automatic reset circuitry and fault indicators — eliminates the cause of most field calls. Dual phone line interface Automatic self tests every 24 hours with report sent to central station. Reports in SIA and most major communications formats. 60 hours of standby power. Operates on loop start phone lines ahead of the building PBX system. A single, programmable output is provided for alarm or dialer failed conditions (cannot be used for evacuation purposes). Specifications Electrical Slave Applications - UL Listed Input: 120 VAC 60 Hz 40 watts Current: Standby 50 mA Alarm 135 mA Stand Alone Applications Input: 120 VAC 60 Hz 40 watts Standby: 12 volt 7 amp hour rechargeable battery 5230 Remote Annunciator (three maximum per system) Load: 60 mA standby 120 mA alarm Indicator Lights (LEDs): Power On (Green) Trouble Silenced (Yellow) Until Trouble is Cleared/Flashing = Supervisory Dialer Failure (Yellow) Telephone Line Fault (2 Red) Inside Cabinet at L1 and L2 Inputs Telephone Requirements: FCC Registration #: AC698R-17462-AL-E RINGER EQUIVALENCE 0.0E Type of Jack: RJ31 X (2 required) l Mechanical: Dimensions: 12.25" W x 14.5" H x 3.0" D 31.1 cm W x 36.8 cm H x 7.6cm D) Weight: 15 lbs. (6.75 kg) Color: Red Optional Accessories: 5230 Remote Annunciator/Programmer 5561 Download Package 7181 Fire Zone Converter Module 7860 Telephone Connecting Cord for RJ31 X Jack (2 required) 6712 12 volt, 7AH rechargeable battery Communication Formats: SIA, SK 3/1, Sescoa 3/1, Contact ID, SK 4/2, Radionics BFSK Approvals: UL Listed - UL864/NFPA 72 Central and Remote Supervising Station Fire Alarm System Service. FM Approved CSFM Approved MEA Model 5230 Remote Alphanumeric Annunciator The 5104E can be programmed through the use of the optional Model 5230 Remote Alphanumeric Annunciator. Programming options include: telephone numbers, reporting format, account number, loop response times (electronic retard), test time, output activation, user and installer codes. System. programming is stored in a non- volatile EEPROM chip which is reprogrammable hundreds of times. The 5104B accommodates up to three remote annunciators via a four -wire connection. A quick - connect plug allows temporary connection of the annunciator for programming. The Model 5561 SKSS Downloading Package Allows for remote programming and status checking of the 5104. Includes a 3 1/2-inch disk and Silent Knight proprietary modem. Allows the installing company to view the default programming, modify it, and if necessary, troubleshoot the system. Designed to be used on an IBM or compatible PC. The downloading software also contains programs for other Silent Knight downloadable products. 5 1/4-inch disks available upon request. 3. r L A LYy L tilt' Power — Limited/Unshielded DESCRIPTION Plenecon H Extra Flexible ASTM bare copper Fuca Polymer alloy insulation Twisted pair or cabled construction Polyester binders as required Flexible plenum jacket RATING UL listed NEC type FPLP Constructed in accordance inch nm inch mina inch pf/ft' pf/m' with UL Standard 1424 Complies with UL 910 testp 60980B 1 1$ Solid 010 Y25 015 38 142 3.61 29 95 modified ASTM Steiner Pair 6.5ON' Tunnel Test 60982B 4 18 Solid 010 y 25 015 38 175 z 4 45 29 95 Meets 300 volt requirement as 6.5 ON P .: k. specified in Section 760 of the NEC 60991E 1 16 Solid 010 25 015 38..161 9 09 32 105 Pair 4.1 S2N APPLICATIONS 60164i3 4 16 Solid 010 25 ; 015 38 220 559 32105 Indoor (non —conduit per NEC) 4.1 s M' Within ducts, plenums and other 60993B 1 14 Solid 012 30 015 38' 191 4 86 35 115 s aces used for environmental air for: P Pair 2.6 d Audio circuits Control circuits 60700E 4 S2/M' 14 Solid 012 30 015 38 252 6 40 35115_ a 3 Initiating circuits 2s ON Notification circuits 60995B 1 12 Solid 012 30 015 38f,:.225 5.72 45 Pair 1.8 ON SPECIAL NOTES Capacitance between conductors. PStandardspoolsize1000feetCapacitanceofunshieldedcablemay , vary depending on he installation environment: INSTALLATION PRECAUTIONS for.;., i a plenum cable: refer to the Technical Reference Section COLOR CODE F WORK KEY PLAN BUILDING 2 NOT TO SCALE RISER DIAGRAM NEW LOAD 0.05 AMPS - STANDBY 0.135 AMPS - ALARM a TO 120 VAC NEW FACP I CITY OF SANFORD FIRE DEPARTMENT FEES FOR SERVICES PHONE # 407-302-2516 • FAX # 407-302-2526 DATE: a// /`7 PERMIT #: BUSINESS NAME / PROJECT: Sfpl?pc Q' r2 i Dw ADDRESS: PHONE NO.: i"- 27fZ7(09 FAX NO.: CONST. INSP. [ ] C / O INS.P.:[ ] REINSPECTION [ ] PLANS REVIEW A/ F. A. [. ] F.S. [ j ` HOOD ] PAINT BOOTH [ ] BURN PERMI ] TENT PERMIT f } TANK PERMIT ( ] OTHER [ } TOTAL FEES; S (PER UNIT SEE BELOW) COMMENTS: Fees must be paid to Sanford Building Department, 300 N. Park Ave., Sanford, FI. 32771 Phone # -407- 330-5656. Proof of Payment must be made to Fire Prevention division before any further services can take place. I certify that the above is true and correct and that will comply with all applicable codes and ordinances of the City of Sanford, Florida. Santo'rdr Preven n-Division Applicant's Signature