Loading...
3865 S Orlando Dr - BC01-000886 (WYNDHAM PLACE ) (DOCUMENTS)CITY OF SANFORD FIRE DEPARTMENT FEES FOR SERVICES PHONE # 407-302-1091 * FAX #: 407-330-5677 DATE: J,1 )100-0 PERMIT #: BUSINESS NAME / PROJECT: uJ Yh © f '4m II' 1-4 e ,i' / T w c ? 4 .4 i D. ADDRESS: 3 8 L:; S• 6 P- L 1+- P PHONENO.: i3— gi"ggg FAXNO.: v , G- S an L o h S T. ,5 N$ r rrr J3 ii ,ti a Y— CONST. INSP. [ ] C / O INSP.:[ ] REINSPECTION [ ] PLANS REVIEW ["]/ F. A. [ ] F.S. [ ] HOOD [ ] PAINT BOOTH [ ] BURN PERMIT [ ] TENT PERMIT [ ] TANK PERMIT [ ] OTHER [ ] TOTAL FEES: S 7';'v 7 PER UNIT SEE BELOW) COMMENTS: j PZ4„3 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. Address / Bldg. # / Unit # Square Footage Fees per Bldg / Unit eL/byoJ3iz 7 z'7 ya,Y c)I,)?3) DID& 1 a. `/ sS3.L uI-?F3 Ui,0c,-. '' 3 lT . 9 `l SS3. S'- 01-w3S 4 z-) 11,ry S S3. CDs - Rp 3 » iz• A tj / 0I-W&I L3i0G 23. .3ar G4• Sir Ji_ D1;' s9b slI, L 01-9,40 a) L3 n 70 SG y 3?1, ag" 01-p i2 Jam' t biz • 11 S. , f7 G S11 B1 7i L I - ?7S3 Fees must be paid to Sanford Building Department, 300 N. Park Ave., Sanford, Fl. 32771 Phone # -407- 330- 5656. Proof of Payment must be made to Fire Prevention division before any further services can take place. 1 certify that the above is true and correct and that I will com II applicable codes and ordinances of the itv of Santbrd, Flom Sanford Fire Prevention Division Applicant's Sign j CITY OF SANFORD PLANS REVIEW COMNfENT SHEET PROJECT: ADDRESS: CONTRACTOR: OWNER: PLANS REVIEWED BY: COMMENTS: DATE BOB BOTT B00000848 l c.'t_i—Or l_O Uol,v, St.1 -C. W- OJAICT PUO IM 1 k:4 PERSON NOTIFIED: PHONE: NO ONE NOTIFIED: DATE RESPONSE RECEIVED: DATE- FAX - APR-05-2001 11:18F, W e. TRI CITY RESIDENTIAL 407 788 2007 P.03iO3 MeW.. New York • (631) T/l ppp Santa Clara. Cardomia • (408) 9gS 24pC UL Underwriters Laboratories Inc. ALLIED MOULDED PRODUCTS INC MR T D KNECHT 222 N UNION ST PO BOX 587 BRYAN OH 435o6 RE: Project Number(s) - 99NK40700 Research Triangle Pak North Carolina •(919) 549-1400 " Camas. Washington • (360) 617- Your most recent listing is shown below. Please review this information and report anyinaccuraciestotheULEngineeringstaffmemberwhohandledyourproject. For information on placing an order for UL Listing Cards in a 3 x 5 inch format, please refer to the enclosed ordering information. CEYY 11,)ay 5, 2000 Outlet Boxes And Fittings Classified For Fire Resistance ALLIED MOULDED PRODUCTS INC R9379222NUNIONSTPOBOX587, BRYAN OH 43506 Series 108Z. 1084,1085, W66,1088,1096, 10", 1099,2300, 2301, 2302, 3300, 3303, M, 9301, M Mt 9305, 9007, 931Z 9313, 9318, 9=. 9324, 9327, 9328, 9331, 9= 9333, 9334, WIS, 9336, 9337, 9338, 9339 9340, 934Z 9W, 9344, nW, 9351, 91365, n%, 939, 9%1, 9363, 93649365. 9066, 9368, 9369, 9370, WZ 9390, 9395 rwnawtank outlet and switch boxes with various suffixes. For use in fire raistmnce walls con- structed of wood or nonbearir steel studs and pst wallboard with Classification periods of 2 his or leas. ClowAnce between boxes andcutoutsitswanshallnotoared1/8 in. MW area"o( n{t (o: boxes shall not a$gre te morn than 300 sy ir+ per 100 sq h of well or eapatrsatiaahacaciawithnoopeningvaeeding28.0 en- Outlet and switch boxes on sides of a wan or partition shall be separated by a hori- zontal distance of not than 24 1n in wa s cmzavdnl 3.1/2 fn WAek- M;O mWCW wool tt gpa,m- Jl ,R h:k. *.un 070pcfgnawsfiberbattinsulation, the norMMi scpawb-n between buuet and ash boxes on oppu6dre the wall or partition mare ' Series 108Z,1084, 1065, 1056, 1089, 1036, 1095, 1099, 2300, 2301, 23OZ 3300, 3303, 9301, WZ 93K 93t16, 9307, 931Z 9313, 9318, 9323, 9Ci24, 9327, 9328. 9331, 9332, "W, 9334, 9335, %X, 9W, 9338, 9339. 9340, 934Z 93419344. 9350, 9351, 9355, 9056, 9358, 9361, 9363, 9364, 9W, 9366, 9C368, 9369, 9370, M 9M, 9395 nonmetallic outlet and switch boxes with various suffixes for use in fire rated gypsum wal board wallminassembliesframedwithm3-5/8in. wide wood studs ad constructed as speQbW in the irdividtml U300 Series Wan and Partition Deign in theFireResistanceDirectory. Clarmce between boxes and cutouts in wall shall not exceed 1/3 is TAe area of opewo for boxes shall not aggregate mom than 100 sq in per 100 sq R of wall or partition area with no opening exceeding 22.0 sq in. Outlet and'switch boxes on badxpce-to- backzon of awallorpartitionshallbeseparatedbyahoritaldistanceof not lesa than 3 ie. provided that the bores arc not installed Series 106Z 1084, 1o85, 1o86,logs, 1096, 1098, 1099, 2300, 2301, 2307, 3300, 3303. 9301, 9302, 9304, 9305, 9C307, 9312, 9313, 9318, 9323, 9324, 9327, 9328, 9331, 933Z 9333, 933b 9XI5, 9336, 9337, 9338, 9339, " 0, 934Z 9343, 93440 9350, 9351, 9355, 9356, 9368, 9361, 9363, 9%C 91365, 9366, 9368, 9369, 9370, 937Z, 9390, 9395 nonmetallic outlet and switch boxes with various suffixes for use in Design No. U351 incvrporatuW s studsandmineralwoolcavityWill. Clearance between bones and cutouts in wall shall not exceed 1 /8 The area of operur+ fire oyes siaU not aggregate more than 100 sq in per 100 sq R of wall or partition area with nv opaung 22.0 sq in. Ouster atfd switch boxyontosidesofawallorpaztdonsNUbeantedbyahorizontaldistamvofnotkss in Series 10t3Z, 1084, 1085, 1086, low, 1096,1098, 1099, 9301, 93K 9306, 9307, 9318, 9323, 913Z1, 9327, 9328, 9331, 9332, 9333, 9334. 9335, 9336, 9337, 9338, 9350, 93S1, 9355, 9356, 9358, 9363, 9364, 9365. 91366, 9368, 9369, 9370, 9390; 9395 noametalk outlet boxes with various suffixes, intended for fixture supports. For use m fire m5istance boor aging amembller coming of wood Boat' wood joists and gypsum wall baud ceiling withClassihmtonperiodsof2hrsorless. Clearance between boxes and cutouts in ceiling shall not P-reed 1/9 in The area of open, ini for boxes stall not aggregate mate, than 265 sq in. per 100 sq R of ceiling area, with no opening exceeding W sq in. No box shall be located within45ftofanotherbox. Types P181, P201, P332. P463 noehaetaWc outlet and switch bourns: For use in fin resistance walls constructed of wood or nonbearing aced studs andgypsumwallboardwithClaasiEeitionperiodsof2hrsorkss. C1essarice between boxes and cutouts in wall rhaU not om 1/8 in The area of openings for boxes shall not aggregate more than 100 sq in per 100 sq A of wall or partition arm with no opening exceeding 22.1sqin. Outlet toes own opposite sides of wall or partition shall be separated by a ft distance of not has Uwh 24 in. Types P181, P201 no emllic outlet bum not intended for fixture support. For use in fire mlistancr Boorcoling assemblies cwnioting of wood ffooywood ' ists and pP= wallboard 1mg with Classificati n periods of 2h or less. CBsraoce between boxes and cutouts m ce!- ing shahnotexceed1/8 in. Carta of op in for boxes shall not ag egato more than 2&5 sq in per 100 sq ft of ceiling area, with no ayerwng exceeding12.5 sq in. No btu shall be shall be located within 4S R of another box. The boxes shall be msu&d in cvmpliarre with the National Elec*"l Code. ZSJr361002 a % I-lor-prclit organization dedicated to public safety and ccmmired to quality service TOTAL P. 03 a..-.-J A INDUSTRY EXCLUSIVE v Uiilg Allied N-loul62doiitllt 2 ( LP-E "W 11 h')"" k- 4I -- -1 - ., I . bI Illl,Unih,mi Bijildin.k! rr. at l!e.],- a lie m l)t2s, vvi addit:e)rml- tiro rc.,i t,ry 1lol I A i"' Allied 'A.'k.-ildc- d itic, mu6meJ inthe sinie sf6d' ate d voalls ia.- oh absoltjldv'ii-:, addi-llx:ll', c w V,- xldiri6n- Y pfntemov Allied pally P Aulation or'' dlterriale (onctru0v,', ti x.l.-Jil-jbic ;) n 'o'6f ',.-eeb, silr", fY. WwW.'alli-edmoulded - c i em -,Jn , riZ- is: S. ti'- 'UL FORM 60OA-97I FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs Residential Whole Building Performance Method A Project Name: 00199 ONE BEDRM TOP Builder: Address: ONE BEDROOM UNIT TOP Permitting Office: SANFORD City, State: SANFORD, FL Permit Number: Owner: WYNDHAM PLACE APTS Jurisdiction Number: 691500 Climate Zone: Central I . Ncw construction or cxistin12 New 12. Coolim" systems 2. Single family or multi -family Multi -family a. Central Unit Cap: 18.0 kl3tu/In _ 3. Number of units, if imulti-family I _ SEER: 10.00 _ 4. Nurnher of Bedrooms I _ b. N/A 5. Is this a worst case? Yes 6. Conditioned floor area (ft') 650 ft' c. N/A 7. Glass area & type a. Clear - single pane 45.0 ft2 _ 13. Heating systems b. Clear - double pane 0.0 ft, _ a. Gas Hydronic Space & Water Hea Cap: 17.0 kl3tu/hr c. Tint/other SC/SHGC - single pane 0.0 W _ RE: 0.77 _ d. Tinl/other SC/SHGC -double pane 0.0 1711 b. N/A S. Floor types a. N A _ c. N/A b. N/A c. NiA 14. Hot water systems Q Nall types _ a. Natural Gas Cap: 40.0 gallons a. Frame. Wood. Exterior R=1 1.0, 171.0 ft2 _ EF: 0.66 _ b. Frame. Wood. Exterior R=11.0, 208.0 ft2 _ b. N/A c. Frame, Wood, Adjacent R=11.0, 208.0 ftz d NJA _.. .. ...__: c. Conservation credits e. N/A HR-Heat recovery, Soiar 10. Ceiling types _ DHP-Dedicated heat pump) a. Under Attic R=30.0, 650.0 ft2 _ 15. HVAC credits b. NIA _ CF-Ceiling fan, CV -Cross ventilation, c. N/A HF-Whole house fan, I I . Ducts _ PT -Programmable Thermostat, a. Sup: Unc. Ret Unc. AH: Not In Attic Sup. R=6.0, 40.0 ft _ RB-Attic radiant barrier, b. N/A MZ-C-Multizone cooling, MZ-H-Multizone heating) Glass/Floor Area: 0.07 Total as -built points: 7190.20 PASSTotalbasepoints: 10141.00 i hereby certify that the plans and specifications covered j i Review of the plans and by this calculation are in compliance with the Florida specifications covered by this sT9rF Energy Code. calculation indicates compliance oFTaE PREPARED $Y: with the Florida Energy Code. 1 Before construction is completed 4 DATE: this building will be inspected for I hereby certify that this building,-as=designed, is in compliance with Section 553.908 e compliance with the Florida Energy Code. Florida Statutes. 1) OWNER/AGENT: - BUILDING OFFICIAL: DATE: DATE: EnergyGauge@ (Version: FLRCNA-200) FORM 60OA-97 SUMMER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: ONE BEDROOM UNIT TOP, SANFORD, FL, PERMIT #: BASE AS -BUILT GLASS TYPES 18 X Conditioned X BSPM = Points Overhang Floor Area Type/SC Ornt Len Hgt Area X SPM X SOF Points 18 650.0 42.08 4923.1 Single, Clear c 0.0 0.0 15.0 59.31 1.00 889.6 Single, Clear E 0.0 0.0 30.0 59.31 1.00 1779.2 As -Built Total: 45.0 2668.8 WALL TYPES Area X BSPM Points Type R-Value Area X SPM Points Adajcent 208.0 0.7 145.6 Frame, Wood, Exterior 11.0 171.0 1.90 324.9 Exterior 379.0 1.90 720.1 Frame, Wood, Exterior 11.0 208.0 1.90 395.2 Frame, Wood, Adjacent 11.0 208.0 0.70 145.6 Base Total: 587.0 865.7 As -Built Total: 587.0 865.7 DOOR TYPES Area X BSPM Points Type Area X SPM Points Adjacent 0.0 0.00 0.0 Exterior 0.0 0.00 0.0 Base Total: 0.0 0.0- As-Built Total: 0:0" " 0.0 CEILING TYPES Area X BSPM Points Type R-Value Area. X SPM Points Under Attic 650.0 0.60 390.0 Under Attic 30.0 650.0 0.60 390.0 Base Total: 650.0 390.0 As -Built Total: 650.0 390.0 FLOOR TYPES Area X BSPM Points Type R-Value Area X SPM Points Slab 0.0(p) 0.0 0.0 Raised 0.0 0.00 0.0 Base Total: 0.0 As -Built Total: 0.0 INFILTRATION Area X BSPM Points Area X SPM Points 650.0 14.31 9301.5 650.0 14.31 9301.5 Summer Base Points: 15480.3 Summer As -Built Points: 13226.0 Total Summer X System = Cooling Total X Cap X Duct X System X Credit Cooling Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points 13226.0 1.000 1.048 0.341 1.000 4726.6 15480.3 0.3577 5537.3 13226.0 1.00 1.048 0.341 1.000 4726.6 EnergyGauge'*' DCA Form 60OA-97 FORM 60OA-97 WINTER CALCULATIONS Residential Whole Building Performance Method A - Details I ADDRESS: ONE BEDROOM UNIT TOP, SANFORD, FL, PERMIT #: I BASE AS -BUILT GLASS TYPES 18 X Conditioned X BWPM Points Overhang Floor Area Type/SC Ornt Len Hgt Area X WPM X WOF Points 18 650.0 4.79 560.4 Single, Clear E 0.0 0.0 15.0 9.96 1.00 149.4 Single, Clear E 0.0 0.0 30.0 9.96 1.00 298.9 As -Built Total: 45.0 448.3 WALL TYPES Area X BWPM Points Type R-Value Area X WPM Points Adajcent 208.0 1.8 374.4 frame, Wood, Exterior 11.0 171.0 1 2.00 342.0 Exterior 379.0 2.00 758.0 Frame, Wood, Exterior 11.0 208.0 2.00 416.0 Frame, Wood, Adjacent 11.0 208.0 1.80 374.4 Base Total: 587.0 1132.4 As -Built Total: 587.0 1132.4 DOOR TYPES Area X BWPM Points Type Area X WPM Points Adjacent 0.0 0.00 0.0 Exterior 0.0 0.00 0.0 Base Total: - _. 0.0 0.0 As -Built Total: Type 0.0_, R-Value -Area X WPM' 0.0 PointsCEILINGTYPESAreaXBWPM = Points Under Attic 650.0 0.60 390.0 Under Attic 30.0 650.0 0.60 390.0 Base Total 650.0 390.0 As -Built Total: 650.0 390.0 FLOOR TYPES Area X BWPM Points Type R-Value Area X WPM Points Slab 0.00) 0.0 0.0 Raised 0.0 0.00 0.0 Base Total: 0.0 As -Built Total: 0.0 INFILTRATION Area X BWPM Points Area X WPM Points 650.0 0.28 182.0 650.0 0.28 182.0 Winter Base Points: 1900.8 Winter As -Built Points: 1788.7 Total Winter X System Heating Total X Cap X Duct X System X Credit = Heating Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points 1788.7 1.000 1.073 0.550 1.000 1055.1 1900.8 1.0730 2039.5 1788.7 1.00 1.073 0.550 1.000 1055.1 EnergyGaugeTm DCA Form 60OA-97 FORM 60OA-97 f WATER HEATING & CODE COMPLIANCE STATUS Residential Whole Building Performance Method A - Details ADDRESS: ONE BEDROOM UNIT TOP, SANFORD, FL, PERMIT #: BASE AS -BUILT WATER HEATING Number of X Multiplier Total Tank EF Number of X Tank X Multiplier X Credit = Total Bedrooms Volume Bedrooms Ratio Multiplier 1 2564.00 2564.0 40.0 0.66 1 1.00 1408.48 1.00 1408.5 As -Built Total: 1408.5 CODE COMPLIANCE STATUS BASE AS -BUILT Cooling + Heating + Points Points Hot Water Points Total Points Cooling Points Heating + Hot Water = Total Points Points Points 5537.3 2039.5 2564.0 10140.8 4726.6 1055.1 1408.5 7190.2 PASS' TBEFS7 94yo,1FO t n f C0D W—, EnergyGaugeT" DCA Form 60OA-97 FORM 609A-97 Code Compliance Checklist Residential Whole Building Performance Method A Details I ADDRESS: ONE BEDROOM UNIT TOP, SANFORD, FL, PERMIT #: 6A-21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST COMPONENTS SECTION REQUIREMENTS FOR EACH PRACTICE CHECK Exterior Windows & Doors 606.1.ABC.1.1 Maximum:.3 cfm/sq:ft. window area; .5 cfm/sq.ft. door area. Exterior & Adjacent Walls 606.1.ABC.1.2.1 Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall; foundation & wall sole or sill plate; joints between exterior wall panels at corners; utility penetrations; between wall panels & top/bottom plates: between walls and floor. EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends from, and is sealed to, the foundation to the top plate. Floors 606.1.ABC.1.2.2 Penetrations/openings >1/8" sealed unless backed by truss or joint members. EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed to the perimeter, penetrations and seams. Ceilings 606.1.ABCA.2.3 Between walls & ceilings; penetrations of ceiling plane of top floor; around shafts, chases, soffits, chimneys, cabinets sealed to continuous air barrier; gaps in gyp board & top plate; attic access. EXCEPTION: Frame ceilings where a continuous infiltration barrier is i installed that is sealed at the perimeter, at penetrations_ and seams. Recessed Lighting Fixtures 606.1.ABC.1.2.4 Type IC rated with no penetrations, sealed; or Type IC or non -IC rated, installed inside a sealed box with 1/2" clearance & 3" from insulation; or Type IC rated with < 2.0 cfm from conditioned space, tested. Multi -story Houses 606..1.ABC_1.2.5 Air barrier on perimeter of floor cavity between floors. Additional Infiltration regts 606.1.ABC.1.3 Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA, have combustion air. 6A-22 OTHER PRESCRIPTIVE MEA5URE5 (must be met or exceeded by all residences. COMPONENTS SECTION REQUIREMENTS CHECK Water.Heateis - 812.1 Comply with efficiency requirements'in Table`6=12. Switch or clearly marked circuit - - breaker (electric) or cutoff (gas) must be provided. External or built-in heat trap required. Swimming Pools & Spas 612.1 Spas & heated pools must have covers (except solar heated). Non-commercial pools must have a pump timer. Gas spa & pool heaters must have a minimum thermal efficiency of 78%. Shower heads 261.11 -_ Water flow must be restricted to no more than 2.5 gallons per minute at 80 PSIG. Air Distribution Systems 610.1 1 All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically attached, sealed, insulated, and installed in accordance with the criteria of Section 610. i Ducts in unconditioned attics: R-6 min. insulation HVAC Controls 607.1 Separate readily accessible manual or automatic thermostat for each system. Insulation 604.1, 602.1 j Ceilings -Min. R-19. Common walls -Frame R-11 or CBS R-3 both sides. Common ceiling & floors R-11. EnergyGaugeTm DCA Form 60OA-97 EnergyGauge@/FIaRES'97 FLRCNA-200 ENERGY PERFORMANCE BEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE SCORE* = 83.8 The higher the score, the more efficient the home. WYNDHAM PLACE APTS,-ONE BEDROOM UNIT TOP, SANFORD, FL, l . New construction or existing Single family or multi -family 3. Number of units, if multi -family 4. Number of Bedrooms Is this a worst case? 6. Conditioned floor area (ft') 7. Glass area & type a. Clear - single pane b. Clear- double pane c. Tinuother SC/SHGC - single pane d. Tinvother SC/SHGC - double pane 8. Floor types a. N/A b. N/A c. N/A 9. Wall types a. Frame. Wood. Exterior b. Frame. Wood, Exterior c. Frame. Wood, Adjacent d. N/A e. N/A 10. Ceiling types a. Under Attic b. N/A c. N/A 11. Ducts a. Sup: Unc. Ret: Unc. AH: Not In Attic b. N/A New _ 12. Cooling systems MUiti-family _ a. Central Unit I _ I _ b. N/A Yes _ 650 ft' c. N/A 45.0 ft' _ 13. Heating systems 0.0 ft' _ a. Gas Hydronic Space & Water Hea 0.0 ft' _ 0.0 ft' b. N/A c. N/A 14. Hot water systems a. Natural Gas R=1 1.0, 171.0 ft' _ R=1 1.0, 208.0 ft' _ b. N/A R=1 1.0, 208.0 ft' _ c. Conservation credits HR-Heat recovery, Solar DHP-Dedicated heat pump) R=30.0, 650.0 ft' _ 15. HVAC credits CF-Ceiling fan, CV -Cross ventilation, HF-Whole house fan, PT -Programmable Thermostat, Sup. R=6.0, 40.0 ft _ RB-Attic radiant barrier, MZ-C-Multizone cooling, MZ-H-Multizone heating) I certify that this home has complied with the Florida Energy Efficiency Code For Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: Address of New Home: Date: City/FL Zip: Cap: 18.0 kBtu/hr SEER: 10.00 Cap: 17.0 kBtu/hr _ RE: 0.77 Cap: 40.0 gallons EF: 0.66 TxE sr9r 4V o 11It Boor) WE NOTE: The home's estimated energy performance score is only available through the FLARES computer program. This is not a Building Energy Rating. !fyour score is 80 or greater (or 86for a US EPA/DOE EnergyStarT'"designation), your hone may qualify for energy efficiency mortgage (EEM) incentives ifyou obtain a Florida Energy Gauge Rating. Contact the Energy Gauge Hotline at 4071638-1492 or see the Energy Gauge web site at www.fsec.ucf.edu for information and a list ofcertified Raters. For information about Florida's Energy Efficiency Code For Building Construction, contact the Department of Community Affairs at 8501487-1824. EnergyGauge® (Version. FLRCNA-200) Air System for ONE E ROO NUNIT TOP Pnojno, I*vamo:VVYNDHAMPLACE APTG 00189 1015m0 / Prepared by: KToCons NngEnginoo OS 18Pm Air System Information System Name ONE BEDROOM UNIT TOP Equipment Class SPLTAHU Number oyZones 1 System Type SZCAv Floor Area 850.0n" Sizing Calculation Information l*.er.` o Space Sizing mrthou zoneCFm Peak zone sensible load Calculation Months Jan toDec GnaooCFm Coincident space loads Sizing Data ua|:u|utou Central Cooling Coil Sizing Data Total coil loam 1orono Load occurs at Jm1mm Sensible coil load 0.8 Tons OADB/mB yz.x/rs.o OF Coil CFmatJul 18nn 573CFm Entering oa/we 77.1/66a^r Max possible CFm 573 CFM Leaving oo/vv8 61.1/60.1 OF Design supply temp. sr.o^r Coil ADP 59.4^F n'/Too 667. 2 Bypass factor 0.100 aTo/»mr 18. 0 ResvuingRH su % Water flow @ , u.o ^Fnuo opm Zone T-souCheck 1 of 0K Central Heating Coil Sizing Data Max coil load 10315 oTUm, Load occurs at oox*tg ) Coil CpMntDes Htg 573CFM 8TUmr/ft' 15.9 | Max possible CFM 573CFw Ent. DB/LvgD8 70J/87.4^p | Water flow @2OU^Fdrop gpm Supply Fan Sizing Data Actual max CFM at Jul 1700 573Cpm Fan motor BHP uooR*p SmmuangCFM 571 CFm Fan motor wV n.onmw Actual max CFM/fp 0.88CFm/ft2 Fan static o.00in. wg. 8utdoorVentilation-Air Data Design airflow CFM OCRN CFM/pomon O.00CFM/pomon Carrier Hourly --— -- ---- -- — -- -Page1 Zone Sizing Summaryfor ONE BEDROOM UNIT TOP Project - Name: WYNDHAM PLACE APTS 00199 10/15/00 Prepared by: KTD Consulting Engineers 09:13 PM Sizing Calculation Information Zone and Space Sizing Method: Zone CFM Peak zone sensible load Calculation Months Jan to Dec Space CFM Coincident space loads Sizing Data Calculated Zone Sizing Data Maximum Design Minimum Time Maximum Cooling Air Air of! Heating; Sensible Flow Flow Peak Load Zone Name MBH) (CFM) CFM) Load MBH)I Zone 1 11.1 573 573 Jul 1700 10.8i Zone Terminal Sizing Data Space Loads and Airflows Cooling! Time Air Heating' Zone Name / Sensible', of! Flow Load Space Name Mult (MBH)i Load CFM) MBH)', Zone 1 ONE B€DRM UNIT TOP 1 11.1 Jul 1700 573 10.8 Carrier Hourly Analysis Program v4.04 Page Air System Design Load Summaryfor ONE BEDROOM UNIT TOP Project Name: WYNDHAM PLACE APTS 00199 10/15/00 Prepared by: KTD Consulting Engineers 09:13 PM ZONE LOADS DESIGN COOLING COOLING DATA AT Jul 160- COOLING OA DB / WB 93.5 °F 175.9 °F Sensible Latenf Details ( BTU/hr) (BTU/hr) DESIGN HEATING HEATING DATA AT DES HTG HEATING OA DB / WB 37.0 °F / 31.1 °F Sensible Latent Details ( BTU/hr) (BTU/hr) Solar Loads 45 tom— 3216 42 Wall Transmission 379 ft2. 1053 379 ft2. 963 Roof Transmission 650 ft2 1310 650 ft2 663 Glass Transmission 45 ft2 878 45 ft2 1934' Skylight Transmission 0 ft2 0 0 ft2: 0 Door Transmission 0 ft2. 0 0 ft2 0: Floor Transmission 0 ft2. 0 0 ft2. 0 Partitions 208 ft2. 1652 208 ft2 3640, Ceiling 0 ft2 0 0 ft2 0 Overhead Lighting ow 0 0 0 Task Lighting 0 W' 0 0 0 Electric Equipment 0 W 0 0: 0 People 2' 490 410 0 0 0 Infiltration 1294 1127 0 3590: 0 Miscellaneous 1200 300 0 0 Safety Factor 0%/0% 0 0 0% 0 0 Total Zone Loads 11092 1837 10790; 0 Zone Conditioning 9854 1887 10315 0 Plenum Wall Load 0% 0 0 0 Plenum Roof Load 0% 0 0 0 Plenum Lighting Load 0% 0 0 0 Return Fan Load 573 CFM 0 573 CFM 0 Ventilation Load O CFM 0 0 0 CFM 0 0 Supply Fan Load 573 CFM 0 573 CFM 0 Space Fan Coil Fans 0 0 Duct Heat Gain / Loss 0% 0 0% 0 Total System Loads 9854 1837 10315- 0 Central Cooling Coil 9854 1837 0 0 Central Heating Coil 0 10315 TotaiConditionir, g 9854:` : 1837 10315. .,._ _.'_"_ .' - 0. Key: Positive values are clg loads Positive values are htg loads Negative values are htg loads Negative values are clg loads Carrier Hourly Analysis -Program v4.04 _ Page 3 Space Design Load Summary for ONE BEDROOM UNIT TOP Project Name: INYNDHAM PLACE APTS 00199 Prepared by: KTD Consulting Engineers 10/15/00 09:13 PM TABLE 1.1.A. COMPONENT LOADS FOR SPACE" ONE BEDRM UNIT TOP" IN ZONE " Zone 1 " DESIGN COOLING DESIGN HEATING COOLING DATA AT Jul 1100 HEATING DATA AT DES HTG OADB/WB 92.3°F/75.6°F IDADB/WB 37.0°F/31.1°F OCCUPIED T-STAT 75.0 °F OCCUPIED T-STAT 72.0 °F Sensible Latent Sensible SPACE LOADS Details (BTU/hr) BTU/hr) Details (BTU/hr) Solar Loads 45 ft2 3380 45 ft2 - Wall Transmission 379 ft2 1165 379 ftZ963 Roof Transmission 650 ft2 1221 650 fti1 663 Glass Transmission 45 ft2 843 45 ft2 1934 Skylight Transmission 0 ft2 0 0 ft2 ` 0 Door Transmission 0 ft2 0 0 ft2 0 Floor Transmission 0 ft2 0 0 ft2 0 Partitions 208 ft2 1587 208 ftZ 3640 Ceiling 0 ft2 0 0 ft2 0 Overhead Lighting 0 W 0 0 0 Task Lighting 0 W' 0 0 0 Electric Equipment 0 W' 0 0 0 People 2 490 410 01 0 Infiltration 1213 1018i - 359& Miscellaneous 1200 300 - 0! Safety Factor 0%/ 0%0. 0 0` 00/0 0 Total Zone Loads 11100 1728 - 10790 W EXPOSURE WALL WINDOW 1 WINDOW 2- N XPOSURE WALL H EXPOSURE ROOF Latent BTU/ hr) 0 0 0 0 0 TABLE 1.1.13. ENVELOPE LOADS FOR SPACE " ONE B'EDRMUNIT TOP " IN ZONE " Zone 1 " COOLING COOLING HEATING Area U-Value Shade TRANS SOLAR TRANS ftZ) ( BTU/hr/ft2/F) Coeff. (BTUlhr); (BTU/hr) (BTU/hr) 171 0.073 i - 15 1.228I 0.916' 30- 1.228; 0.916' 208 0.073 650 0.0291 747 435 281 1127 645 562' 2254 - - 1289 418 529 1221 663 Carrier Hourly Analysis Program v4.-04 age v FORM 60QA-97 FLORIDA ENERGY FFICIE CY CODE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs Residential Whole Building Performance Method A Project Name: 00199 TWO BEDRM TOP Address: TWO BEDROOM UNIT TOP City, State: SANFORD, FL Owner: WYNDHAM PLACE APTS Climate Zone: Central Builder: Permitting Office: Permit Number: Jurisdiction Number SANFORD 691500 1- New construction or existing New _ 12. Cooling systems 2. Single family or multi -family Multi -family _ a. Central Unit Cap: 24.0 Mtu/lu 3. NUmber of Units. if multi-fanli-Iv 1 _ SEER: 10.00 4. Number of Bedrooms 2 _ b. N/A Is this a worst case? Yes _ 6. Conditioned Floor area (112) 925 ft' c. N/A T Glass area & type a. Clear - single pane 45.0 ft' 13. Heating systems b. Clear - double pane 0.0 ft2 _ a. Gas Hydronic Space & Water Hea Cap: 17.0 kBtu/hr c, TinUother SC/SHGC - single pane 0.0 ft' _ RE: 0.77 d. Tint/other SC/SHGC - double pane 0.0 ft2 b. N/A S. Floor types a. NIA c. N/A b.NA c. N/A 14. Hot water systems 9. Nall types a. Natural Gas Cap: 40.0 gallons _ a. frame. Wood, Exterior R=11.0, 171.0 ft2 _ EF: 0..66 b. Frame. Wood, Exterior R=11.0, 208.0 ft2 _ b. N/A c. Frame, Wood, Adjacent R=1 1.0, 208.0 ft2 _ d. N!A c. Conservation credits e. iviA HR-Heat recovery, polar 10. Ceiling types DHP-Dedicated heat pump) a. Under Attic R=30.0, 650.0 ft2 15. HVAC credits b. N/A CF-Ceiling fan, CV -Cross ventilation, c. N/A HF-Whole house fan, 11. Ducts PT -Programmable Thermostat, a. Sup: Unc. Ret: Unc. AH: Not In Attic Sup. R=6.0, 40.0 ft KB -Attic radiant barrier, b. N/A MZ-C-Multizone cooling, MZ-H-Multizone heating) Glass/Floor Area: 0.05 Total as -built points: 9959.60 PASSTotalbasepoints: 15029.00 1 hereby certify that the plans and specifications covered I Review of the plans and by this calculation are in compliance with -the Florida ; ; specifications covered by this o4T8ESTgTF Energy Code. calculation indicates compliance PREPARED BY: L with the Florida Energy Code. 'o DATE:7 Before construction is completed M o this building will be inspected for I hereby certify that'this building, as designed; is in compliance with Section 553.908 compliance with the Florida Energy Code. Florida Statutes. cODJ OWNER/AGENT: _ BUILDING OFFICIAL: DATE: DATE: EnergyGauge® (Version: FLRCNA-200) E FORM 60OA-97 SUMMER CALCULATIONS Residential Whole Building Performance Method A - Details I ADDRESS: TWO BEDROOM UNIT TOP, SANFORD, FL, PERMIT #: BASE AS -BUILT GLASS TYPES 18 X Conditioned X BSPM = Points Overhang Floor Area Type/SC Ornt Len Hgt Area X SPM X SOF Points 18 925_0 42.08 7005.9 Single, Clear E 0.0 0.0 15.0 59.31 1.00 889.6 Single, Clear E 0.0 0.0 30.0 59.31 1.00 1779.2 As -Built Total: 45.0 2663.8 WALL TYPES Area X BSPM Points Type R-Value Area X SPM Points Adajcent 208.0 0.7 145.6 Frame, Wood, Exterior 11.0 171.0 1.90 324.9 Exterior 379.0 1:90 720.1 Frame, Wood, Exterior 11.0 208.0 1.90 395.2 Frame, Wood, Adjacent 11.0 208.0 0.70 145.6 Base Total: 587.0 865.7 As -Built Total: 587.0 865.7 DOOR TYPES Area X BSPM Points Type Area X SPM Points Adjacent 0.0 0.00 0.0 Exterior 0.0 0.00 0.0 Base Total: 0.0 0.0 As -Built Total: 0.0 0.0 CEILING TYPES Area X BSPM Points Type R-Value Area X SPM Points Under Attic 650.0 0.60 390.0 Under Attic 30.0 650.0 0.60 390.0 Base Total: 650.0 390.0 As -Built Total: 650.0 390.0 FLOOR TYPES Area X BSPM Points Type R-Value Area X SPM Points Slab 0.0(p) 0.0 0.0 Raised 0.0 0.00 0.0 Base Total: 0.0 As -Built Total: 0.0 INFILTRATION Area X BSPM Points Area. X SPM Points 925.0 14.31 13236.8 925.0 14.31 13236.8 Summer Base Points: 21498.3 Summer As -Built Points: 17161.3 Total Summer X System = Cooling Total X Cap X Duct X System X Credit Cooling Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points 17161.3 1.000 1.048 0.341 1.000 6132.9 21498.3 0.3577 7690.0 17161.3 1.00 1.048 0.341 1.000 6132.9 EnergyGaugeTm DCA Form 60OA-97 F_ - . FORM 60OA-97 WINTER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: TWO BEDROOM UNIT TOP, SANFORD, FL, PERMIT #: BASE AS -BUILT GLASS TYPES 18 X Conditioned X BWPM = Points Overhang Floor Area Type/SC Ornt Len Hgt Area X WPM X WOF Points 18 925.0 4,79 797.5 Single, Clear E 0.0 0.0 15.0 9.96 1.00 149.4 Single, Clear E 0.0 0.0 30.0 9.96 1.00 298.9 As -Built Total: 45.0 448.3 WALL TYPES Area X BWPM Points Type R-Value Area X WPM Points Adajcent 208.0 1.8 374.4 Frame, Wood, Exterior 11.0 171.0 2.00 342.0 Exterior 379.0 2.00 758.0 Frame, Wood, Exterior 11.0 208.0 2.00 416.0 Frame, Wood, Adjacent 11.0 208.0 1.80 374.4 Base Total: 587.0 1132.4 As -Built Total: 587.0 1132.4 DOOR TYPES Area X BWPM Points Type Area X WPM Points Adjacent 0.0 0.00 0.0 Exterior 0.0 0.00 0.0 aye ota ....... .. .... 0:0 ._ 0:0....__As=6uilfTotal: Type 0:0 R-Value Area X WPM 0.0 - PointsCEILINGTYPESAreaXBWPM = Points Under Attic 650.0 0.60 390.0 Under Attic 30.0 650.0 0.60 390.0 Base Total: 650.0 390.0 As -Built Total: 650.0 390.0 FLOOR TYPES Area X BWPM Points Type R-Value Area X WPM Points Slab 0.0(p) 0.0 0.0 Raised 0.0 0.00 0.0 Base Total: 0.0 As -Built Total: 0.0 INFILTRATION Area X BWPM Points Area X WPM Points 925.0 0.28 259.0 925.0 0.28 259.0 Winter Base Points: 2060.9 Winter As -Built Points: 1711.7 Total Winter X System Heating Total X Cap X Duct X System X Credit = Heating Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points 1711.7 1.000 1.073 0.550 1.000 1009.7 2060.9 1.0730 2211.3 1711.7 1.00 1.073 0.550 1.000 1009.7 EnergyGaugeTm DCA Form 60OA-97 FORM 600,A-97 WATER HEATING & CODE COMPLIANCE STATUS Residential Whole Building Performance Method A - Details ADDRESS: TWO BEDROOM UNIT TOP, SANFORD, FL, PERMIT #: BASE AS -BUILT WATER HEATING Number of X Multiplier = Total Tank EF Number of X Tank X Multiplier X Credit = Total Bedrooms Volume Bedrooms Ratio Multiplier 2 2564.00 5128.0 40.0 0.66 2 1.00 1408.48 1.00 2817.0 As -Built Total: 2817.0 CODE COMPLIANCE STATUS BASE AS -BUILT Cooling + Heating + Points Points Hot Water Points Total Points Cooling Points Heating + Hot Water = Total Points Points Points 7690.0 2211.3 5128.0 15029.3 6132.9 1009.7 2817.0 9959.6 PASS 0' SHE ST9? rprr ••" t O uJ 04 _ C7 t7 y f Y EnergyGaugeTm DCA Form 60OA-97 k FORM 60OA-97 Code Compliance Checklist Residential Whole Building Performance Method A - Details ADDRESS: TWO BEDROOM UNIT TOP, SANFORD, FL, PERMIT #: 6A-21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST COMPONENTS SECTION REQUIREMENTS FOR EACH PRACTICE CHECK Exterior Windows & Doors 606.1.ABC.1.1 Maximum:.3 cfm/sq.ft. window area; .5 cfm/sq.ft. door area. Exterior & Adjacent Walls 606.1.ABC.1.2.1 Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall; foundation & wall sole or sill plate; joints between exterior wall panels at corners; utility penetrations; between wall panels & top/bottom plates; between walls and floor. EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends from, and is sealed to, the foundation to the top plate. Floors 606.1 .ABC. 1.2.2 Penetrations/openings >1/8" sealed unless backed by truss or joint members. EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed to the perimeter, penetrations and seams. Ceilings 606.1.ABC.1.2.3 Between walls & ceilings; penetrations of ceiling plane of top floor, around shafts, chases. soffits, chimneys, cabinets sealed to continuous air barrier; gaps in gyp board & top plate, attic access. EXCEPTION: Frame ceilings where a continuous infiltration barrier is installed that is sealed at the perimeter, at penetrations and seams. Recessed Lighting Fixtures 606.1.ABC.1.2.4 Type IC rated with no penetrations, sealed; or Type IC or non -IC rated, installed inside a sealed box with 1/2" clearance & 3" from insulation; or Type IC rated with < 2.0 cfm from conditioned space, tested. Multi -story Houses 606.1.ABC.1.2.5 Air barrier on perimeter of floor cavity between floors. Additional Infiltration reqts 606.1.ABC.1.3 Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA, have combustion air. bA-22 U I HER PRESCRIPTIVE MEASURES (must be met or exceeded by all residences. COMPONENTS , ._,,. _ 'SECTION 1 REQUIREMENTS _ - _ CHECK,I Water Heaters 6 i2.1 Comply with efficiency requirements in Table 6-12. Switch or ciearly marked circuit breaker (electric) or cutoff (gas) must be provided. External or built-in heat trap required. Swimming Pools & Spas 612.1 Spas & heated pools must have covers (except solar heated). Non-commercial pools must have a pump timer. Gas spa & pool heaters must have a minimum thermal efficiency of 78%. Shower heads 612.1 Water flow must be restricted to no more than 2.5 gallons per minute at 80 PSIG. Air Distribution Systems 610.1 li All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically attached, sealed, insulated, and installed in accordance with the criteria of Section 610. I Ducts in unconditioned attics: R-6 min. insulation. HVAC Controls 607.1 Separate readily accessible manual or automatic thermostat for each system. Insulation 604.1, 602.1 Ceilings -Min. R-19. Common walls -Frame R-11 or CBS R-3 both sides. i Common ceiling & floors R-11. EnergyGaugeTm DCA Form 60OA-97 EnergyGauge®/RaRES'97 FLRCNA-200 ENERGY PERFORMANCE LEVEL (EPL) DISPLAYCA12D ESTIMATED ENERGY PERFORMANCE SCORE* = 84.7 The higher the score, the more efficient the home. WYNDHAM PLACE APTS, TWO BEDROOM UNIT TOP, SANFORD, FL, I . New construction or existing New _ 12. Cooling systems Single family or multi -family Multi -family _ a. Central Unit Number of units. if multi -family I _ 4. Number of Bedrooms 2 _ b. N/A S. Is this a worst case? Yes _ 6. Conditioned floor area (ft') 925 ft' c. N/A 7. Glass area & type a. Clear -single pane 45.0 Ft' _ 13. Heating systems b. Clear - double pane 0.0 ft' _ a. Gas Hydronic Space & Water Hea c. Tint/other SC/SHGC - single pane 0.0 ft2 _ d. TinUother SC/SHGC - double pane 0.0 ft2 b. N/A S. Floor types a. N/A c. N/A b. N/A c. N/A 14. Hot water systems 9. Wall types a. Natural Gas a. Frame, Wood, Exterior R=11.0, 171.0 ft2 _ b. Frame, Wood, Exterior R=11.0, 208.0 ft2 _ b. N/A c. Frame, Wood, Adjacent R=11.0, 208.0 ft' _ d. N!A _ _ cCnnservation credits e. N/ A HR-Heat recovery, Solar 10. Ceiling types DHP-Dedicated heat pump) a. Under Attic R=30.0, 650.0 ft' _ 15. HVAC credits b. N/ A CF-Ceiling fan, CV -Cross ventilation, c. N/ A HF-Whole house fan, 11. Ducts PT -Programmable Thermostat, a. Sup: Unc. Ret: Unc. AH: Not In Attic Sup. R=6.0, 40.0 ft _ RB-Attic radiant barrier, b. N/ A MZ-C-Multizone cooling, MZ-H- Multizone heating) I certify that this home has complied with the Florida Energy Efficiency Code For Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: Address of New Home: Date: City/ FL Zip: Cap: 24. 0 k13tu hr SEER: 10. 00 -- Cap: 17. 0 kBtu/hr _ RE: 0. 77 Cap: 40. 0 gallons _ EF: 0. 66 y 4 THE STd DWE' NOTE: The home's estimated energy performance score is only available through the FLARES computer program. This is not a Building Energy Rating. If your scoreis 80 or greater (or 86 for aUS EPA/DOE EnergyStarTudesignation), your home may qualify for energy efficiency mortgage (EEM) incentives if you obtaina Florida Energy Gauge Rating. Contact the Energy Gauge Hotline at 4071638-1492 or see the Energy Gauge tveb site at www.fsec.ucf.edu forinformation and a list of certified Raters. For information about Florida's Energy Efficiency Code For Building Construction, contact the Department of Community Affairs at 8501487-1824. EnergyGauge® (Version: FLRCNA-200) Air System Sizing Summary for TWO BEDROOM UNIT TOP Project Name: VVYNDHAM PLACE APTS 00199 Prepared by: KTD Consulting Engineers Air System Information System Name TWO BEDROOM UNIT TOP Equipment Class SPLT AHU Number of Zones 1 System Type SZCAV Floor Area 925.0 ft2 Sizing Calculation Information Zone and Space Sizing Method: Zone CFM Peak zone sensible load Calculation Months Jan to Dec Space CFM Coincident space loads Sizing Data Calculated Central Cooling Coil Sizing Data 10/15/00 09:13 PM Total coil load 1.3 Tons Load occurs at Jul 1700 Sensible coil load 1.1 Tons OA DB / WB 92.3 / 75.6 °F Coil CFM at Jul 1700 740 CFM Entering DB / WB 77.1 / 66.6 °F Max possible CFM 740 CFM Leaving DB / WB 61.0 / 60.0 °F Design supply temp. 57.0 °F Coil ADP 59.2 °F ft2/Ton 721.7 Bypass factor 0.100 BTU/hr/ft2 16.6 Resulting RH 58 % Water flow @ 10.0 °F rise gpm Zoi,e T-stat Check 1 of 1 OK Central Heating Coil Sizing Data Max coil load 13446 BTU/hr Load occurs at Des Htg Coil CFM at Des Htg 740 CFM BTU/hr/ft2 14.5 Max possible CFM 740 CFM Ent. DB / Lvg DB 71.0 / 87.9 `F Water flow @ 20.0 °F drop gpm Supply Fan Sizing Data Actual max CFM at Jul 1700 740 CFM Fan motor BHP 0.00 BHP Standard CFM 737 CFM Fan motor kW 0.00 kW Actual max CFM/ft2 0.80 CFM/ft2 Fan static 0.00 in. wg. Outdoor Ventilation Air Data Desi n <iirf!ow.'CFV 0 CFM CFM/person G.00 CFM/pemori CFM/ft2 0.00 CFM/ft2 Carrier Hourly Analysis -Program v4.04 - - _ Page 9 Zone Sizing Summary for TWO BEDROOM UNIT TOP Project Name: NYNDHAM PLACE APTS 00199 Prepared by: KTD Consulting Engineers Sizing Calculation Information Zone and Space Sizing Method: Zone CFM Peak zone sensible load Calculation Months Jan to Dec Space CFM Coincident space loads Sizing Data Calculated Zone Sizing Data Maximum Design I Minimum Time Maximum Cooling Air' Air of! Heating Sensible Flow Flow Peak Load Zone Name MBH) (CFM) CFM) Load MBH) Zone 1 14.3 740 740 Jul 1700 13.4 Zone Terminal Sizing Data Space Loads and Airflows Cooling Time Air Heating' Zone Name % Sensible of Flow Load' Space Name Mult (MBH) Load (CFM) MBH), TWO BEDRM UNIT TOP 1 14.3 Jul 1700 740 13.4 10/ 15/00 09:13 PM Carrier Hourly Analysis Program J4.04 Page 10 Air System Design Load Summary for TWO BEDROOM UNIT TOP Projecl Name: WYNDHAM PLACE APTS 00199 10/15/00 Prepared by: KTD Consulting Engineers 09:13 PM DESIGN COOLING - DESIGN HEATING iCOOLING -DATA ATJul -116-0-- - HEATING DATA AT - DES -HTG iCOOLING OA 13113 WB 92.3 *F 175.6 *F :HEATING OA DB WB 37.0 *F 31.1 F Sensible Latent Sensible Latent ZONE LOADS Details (BTU/hr) BTU/hr); Details (BTU/hr) BTU/hr) Solar Loads..-_. oads-- - - -- - - 60—ft2 — 4507 60 t2 Wall Transmission 460 ft2 1519 460 ft2: 1169 Roof Transmission 925 ft2 11738i 7 925 W; 943 Glass Transmission 60 ft2 1125: 60 f[2.2579* Skylight Transmission 0 ft2. 0, 0 ft2 0 Door Transmission 0 -ft2 0 0 ft, 0 Floor Transmission 0 ft2.0 0 ft2; 0 Partitions 208 ft2 1587 208 ft2 3640 Ceiling 0 ft2 0 0 ft2 0 Overhead Lighting ow 0 0 0 Task Lighting ow 0 01 0 Electric Equipment ow 0 ot 0 People 3 735 615i 00 0 Infiltration 1726 161071 0: 5109 0 Miscellaneous 1400 300: 0 0 Safety Factor 0%/0% 0 0 0%* 0 0 Total Zone Loads 14336 2525; 13440 0 Zone Conditioning 12855 25251 13446 0 Plenum Wall Load 0% 0 0: 0 Plenum Roof Load 0% 0 01 0 Plenum Lighting Load 0% 0 01 0 Return Fan Load 740 CFM 0 740 CFM 0 Ventilation Load 0 CFM 0 01 0 CFM 0 0 Supply Fan Load 740 CFM 0 740 CFM 0 Space Fan Coil Fans 0 0* Duct Heat Gain / Loss 0% 0 0% 0 Total System Loads 12855 2625 13446 0 Central Cooling Coil 12855 2526 0 0 Central Heatirig- Coil 01- 13446 Total -Conditioning 12855, 0 Key: Positivevaluesare cllg- loads Positive values are fit-4 loads Negative valuesare htg loads Negative values are cig loads Carrier Hourly AnalysisProgramV4.0- 47 Page 11 Space Design Load Summary for TWO BEDROOM UNIT TOP Projec; Name: WYNDHAM PLACE APTS 00199 Prepared by: KTD Consulting Engineers TABLE 1.1.A. COMPONENT LOADS- FOR SPACE " TWO BEDRM UNIT TOP IN ZONE " Zone 1 DESIGN COOLING DESIGN HEATING ICOOLING DATA AT Jul 1700 HEATING DATA AT DES HTG jOA DB / WB 92.3 *F / 75.6 *F IOA DB I WB 37.0 *F / 31.1 *F OCCUPIED T-STAT 75.0 *F iOCCUPIED T-STAT 72.0 *F Sensible Latent Sensible SPACE LOADS Details (BTU/hr)i BTU/hr)! Details (BTU/hr) Solar Loads 60 ff2 47507 60 ft' - Wall Transmission 460 A2 1-51911 460 ft2 1169 Roof Transmission 025 ft2 925 ft2: 943, Glass Transmission 60 ft2' 1125; 60 ft2 2579 Skylight Transmission 0 ft2: OTI 0 ft2 6 Door Transmission 0 f12 0' 0 ft2 0 Floor Transmission 0 f12 0! 0 ft2 0 Partitions 208 ft2 1587 208 f12 3640 Ceiling 0 ft2 0 0 ft2 0 Overhead Lighting ow 0. 0 0 Task Lighting 0 W 0: 1 0:1 0 Electric Equipment 0 Wi 01 0 0: People 3: 7351 6151 0 0 Infiltration 1726i 1610! - 5109 Miscellaneous 1400i 300: - 0 Safety Factor 0%/00/0" 0! 0 0% 0 Total Zone Loads 14336, 2525, - 13440 10/15/00 09:13 PM Latent BTU/hr) 0 0 0 0 0 TABLE 1.1.13. ENVELOPE LOADS FOR SPACE " TWO BEDIRM UNIT TOP " IN ZONE " Zone I COOLING COOLING HEATING Area U-Value; Shade i TRANS SOLAR, TRANS! ft-)! (13TU/hr/ft2fl' Coeff. (BTU/hr)' (BTU/hr)(BTU/hr) WALL 252 0.073 - 1101 WINDOW 1 30 1.228 0.916 562 WINDOW 2 30 1.229. 0.916:. 562 WALL 20 1 & 0.073 4 - 1 1 8 . H EXPOSURE ROOF 925- 0.0291 1-73-81 640 2254 1289 2254 1289 529 943 Carrier Hourly Ahalysis Program v4-.04 - ------ Page 12 FORM 60OA-97 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs Residential Whole Building Performance Method A Project Name: 00199 THREE BEDRM TOP Builder: Address: THREE BEDROOM UNIT TOP Permitting Office: SANFORD City, State: SANFORD, FL Permit Number: Owner: WYNDHAM PLACE APTS Jurisdiction Number: 691500 Climate Zone: Central l . New construction or existing New _ 12. Cooling systems 2. Single family or multi -family Multi -family _ a. Central Unit Cap: 24.0 kBtu/hr 3. Number of units, if multi -family I _ SEER: 10.00 4. Number of Bedrooms 3 _ b. N/A 5. Is this a worst case'? Yes 6. Conditioned floor area (112) 1089 ft2 c. N/A 7. Glass area & type a. Clear - single pane 75.0 ft2 _ 13. Heating systems b. Clear - double pane 0.0 ft2 _ a. Gas Hydronic Space & Water Hea Cap: 17.0 kBtu/hr c. Tint/other SC/SHGC - single pane 0.0 ft2 _ RE: 0.77 d. TinUother SC/SHGC - double pane 0.0 112 b. N/A S. Floor types a. N/A c. N/A b. N!A c. N/A 14. Hot water systems 9. Wall types a. Natural Gas Cap: 40.0 gallons a. Frame, Wood, Exterior R=1 1.0, 260.0 W _ EF: 0.00 b. Frame, Wood, Exterior R=11.0, 32.0 ft2 _ b. N/A c. Frame, Wood, Adjacent R=11.0, 208.0 W d. Frame, Wood. Exterior. . R=11.0, 225.0 ft2 c. Conservation credits e. N/A HR-Heat recovery, Solar 10. Ceiling types DHP-Dedicated heat pump) a. Under Attic R=30.0, 1089.0 ft2 _ 15. HVAC credits b. N/A CF-Ceiling fan, CV -Cross ventilation, c. N/A HF-Whole house fan, 11. Ducts PT -Programmable Thermostat, a. Sup: Unc. Ret: Unc. AH: Not In Attic Sup. R=6.0, 40.0 ft - RB-Attic radiant barrier, b. N/A MZ-C-Multizone cooling, MZ-H-Multizone heating) Glass/Floor Area: 0.07 Total as -built points: 13400.00 PASSTotalbasepoints: 19746.00 I hereby certify that the plans and specifications covered 1 Review of the plans and 011 by this calculation are in cornpliance with the Florida specifications covered by this o TKEsrgT Energy Code. calculation indicates compliance PREPARED IY::-CA _ with the Florida Energy Code. Before construction is completed vDATE: 4 this building will be inspected for I hereby certify that this building; as designed, is in compliance with Section 553.908 frlo v5 compliance with the Floridb'Errsrgy Code. Florida Statutes. ° OWNER/AGENT: BUILDING OFFICIAL: DATE: j DATE: 5" i EnergyGauge® (Version: FLRCNA-200) FORM 60QA-97 SUMMER CALCULATIONS Residential Whole Building Performance Method A - Details I ADDRESS: THREE BEDROOM UNIT TOP, SANFORD, FL, PERMIT #: I BASE AS -BUILT GLASS TYPES 18 X Conditioned X BSPM = Points Overhang Floor Area Type/SC Ornt Len Hgt Area X SPM X SOF Points 18 1089.0 42.08 8248.0 Single, Clear E 0.0 0.0 30.0 59.31 1.00 1779.2 Single, Clear E 0.0 0.0 30.0 59.31 1.00 1779.2 Single, Clear S 0.0 0.0 15.0 44.66 1.00 669.9 As -Built Total: 75.0 4228.3 WALL TYPES Area X BSPM Points Type R-Value Area X SPM Points Adajcent 208.0 0.7 145.6 Frame, Wood, Exterior 11.0 260.0 1.90 494.0 Exterior 517.0 1.90 982.3 Frame, Wood, Exterior 11.0 32.0 1.90 60.8 Frame, Wood, Adjacent 11.0 208.0 0.70 145.6 Frame, Wood, Exterior 11.0 225.0 1.90 427.5 Base Total: 725.0 1127.9 As -Built Total: 725.0 1127.9 DOOR TYPES Area X BSPM Points Type Area X SPM Points Adjacent 0.0 0.00 0.0 Exterior 0.0 ° - ..0.10 0:0 Base Total: 0.0 0.0 As -Built Total: 0.0 0.0 CEILING TYPES Area X BSPM Points Type R-Value Area X SPM Points Under Attic 1089.0 0.60 653.4 Under Attic 30.0 1089.0 0.60 653.4 Base Total: 1089.0 653.4 As -Built Total: 1089.0 653.4 FLOOR TYPES Area X BSPM Points Type R-Value Area X SPM Points Slab 0.0(p) 0.0 0.0 Raised 0.0 0.00 0.0 Base Total: 0.0 As -Built Total: 0.0 INFILTRATION Area X BSPM Points Area X SPM Points 1089.0 14.31 15583.6 1089.0 14.31 15583.6 Summer Base Points: 25612.9 Summer As -Built Points: 21593.2 Total Summer X System = Cooling Total X Cap X Duct X System X Credit = Cooling Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points 1 21593.2 1.000 1.048 0.341 1.000 7716.7 25612.9 0.3577 9161.7 21593.2 1.00 1.048 0.341 1.000 7716.7 EnergyGaugeTm DCA Form 60OA-97 FORM 60OA-97 WINTER CALCULATIONS Residential Whole Building Performance Method A Details ADDRESS: THREE BEDROOM UNIT TOP, SANFORD, FL, PERMIT #: BASE AS -BUILT GLASS TYPES 18 X Conditioned X BWPM Points Overhang Floor Area Type/SC Ornt Len Hgt Area X WPM X WOF Points 18 1089.0 4.79 938.8 Single, Clear E 0.0 0.0 30.0 9.96 1.00 298.9 Single, Clear E 0.0 0.0 30.0 9.96 1.00 298.9 Single, Clear S 0.0 0.0 15.0 7.73 1.00 116.0 As -Built Total: 75.0 713.7 WALL TYPES Area X BWPM Points Type R-Value Area X WPM Points Adajcent 208.0 1.8 374.4 Frame, Wood, Exterior 11.0 260.0 2.00 520.0 Exterior 517.0 2.00 1034.0 Frame, Wood, Exterior 11.0 32.0 2.00 64.0 Frame, Wood, Adjacent 11.0 208.0 1.80 374.4 Frame, Wood, Exterior 11.0 225.0 2.00 450.0 Base Total: 725.0 1408.4 As -Built Total: 725.0 1408.4 DOOR TYPES Area X BWPM Points Type Area X WPM Points Adjacent 0.0 0.00 0.0 Exterior.. 0.0_ _ O.OF 0.0 Base Total: 0.0 0.0 As -Built Total: 0.0 0.0 CEILING TYPES Area X BWPM Points Type R-Value Area X WPM Points Under Attic 1089.0 0.60 653.4 Under Attic 30.0 1089.0 0.60 653.4 Base Total: 1089.0 653.4 As -Built Total: 1089.0 653.4 FLOOR TYPES Area X BWPM Points Type R-Value Area X WPM Points Slab 0.0(p) 0.0 0.0 Raised 0.0 0.00 0.0 Base Total: 0.0 As -Built Total: 0.0 INFILTRATION Area X BWPM Points Area X WPM Points 1089.0 0.28 304.9 1089.0 0.28 304.9 Winter Base Points: 2695.7 Winter As -Built Points: 2470.6 Total Winter X System Heating Total X Cap X Duct X System X Credit = Heating Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points 2470.6 1.000 1.073 0.550 1.000 1457.4 2695.7 1.0730 2892.5 2470.6 1.00 1.073 0.550 1.000 1457.4 EnergyGaugeTA° DCA Form 60OA-97 FORM 60QA-97 WATER HEATING & CODE COMPLIANCE STATUS Residential Whole Building Performance Method A - Details I ADDRESS: THREE BEDROOM UNIT TOP, SANFORD, FL, PERMIT #: BASE AS -BUILT WATER HEATING Number of X Multiplier Total Tank EF Number of X Tank X Multiplier X Credit = Total Bedrooms Volume Bedrooms Ratio Multiplier 3 2564.00 7692.0 40.0 0.66 3 1.00 1408.48 1.00 4225.5 As -Built Total: 4225.5 CODE COMPLIANCE STATUS BASE AS -BUILT Cooling + Heating + Points Points Hot Water Points Total Points Cooling Points Heating + Hot Water = Total Points Points Points 9161.7 2892.5 7692.0 19746.3 7716.7 1457.4 4225.5 13399.5 PASS wP oFTKEFSTgTFO A. f COD W"F EnergyGaugeTm DCA Form 60OA-97 FORM 600.A-97 Code Compliance Checklist Residential Whole Building Performance Method A - Details I ADDRESS: THREE BEDROOM UNIT TOP, SANFORD, FL, PERMIT #: 6A-21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST COMPONENTS SECTION REQUIREMENTS FOR EACH PRACTICE CHECK Exterior Windows &Doors 606.1.ABC.1.1 i Maximum:.3 cfm/sq.ft. window area; .5 cfm/sq.ft. door area. Exterior & Adjacent Walls 606.1.ABC.1.2.1 Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall: foundation & wall sole or sill plate; joints between exterior wall panels at corners; utility penetrations; between wall panels & top/bottom plates; between walls and floor. EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends from, and is sealed to, the foundation to the top plate. Floors 606.1.ABC.1-2.2 Penetrations/openings >1/8" sealed unless backed by truss or joint members. EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed to the perimeter, penetrations and seams. Ceilings 606.1.ABC.1.2.3 Between walls & ceilings; penetrations of ceiling plane of top floor; around shafts, chases, soffits, chimneys, cabinets sealed to continuous air barrier; gaps in gyp board & top plate; attic access. EXCEPTION: Frame ceilings where a continuous infiltration barrier is installed that is sealed at the perimeter, at penetrations and seams. Recessed Lighting Fixtures 606.1.ABC.1.2.4 Type IC rated with no penetrations, sealed; or Type IC or non -IC rated, installed inside a sealed box with 1/2" clearance & 3" from insulation; or Type IC rated with < 2.0 cfm from conditioned space, tested. Multi -story Houses 606.1.ABC.1.2.5 Air barrier on perimeter of floor cavity between floors. Additional Infiltration reqts 606.1.ABC.1.3 Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA, have combustion air. Swimming Pools & Spas 612.1 Shower heads 612.1 Air Distribution Systems 610.1 HVAC Controls 607.1 Insulation 604.1, 602.1 EASURES (must be met or exceeded by all residences. REQUIREMENTS Comply -with -efficiency regyirements in Table 6-12. Switch or clearly marked circuit breaker (electric) or cutoff (gas) must be provided_ External or built-in heat trap required. Spas & heated pools must have covers (except solar heated). Non-commercial pools must have a pump timer. Gas spa & pool heaters must have a minimum thermal efficiency of 78%. Water flow must be restricted to no more than 2.5 gallons per minute at 80 PSIG. All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically attached, sealed, insulated, and installed in accordance with the criteria of Section 610. Ducts in unconditioned attics: R-6 min. insulation. Separate readily accessible manual or automatic thermostat for each system, Ceilings -Min. R-19. Common walls -Frame R-11 or CBS R-3 both sides. Common ceiling & floors R-11. CHECK EnergyGaugeTm DCA Form 60OA-97 EnergyGauge®/FlaRES'97 FLRCNA-200 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE SCORE* = 84.0 The higher the score, the more efficient the home. WYNDHAM PLACE APTS, THREE BEDROOM UNIT TOP, SANFORD, FL, l New construction or existing New — 12. Cooling systems 2. Single famiiv ormuiti-family Multi -family _ a. Central Unit Number of units, if multi -family I _ 4. Number of Bedrooms 3 _ b. N/A 5. Is this a worst case? Yes _ 6. Conditioned Floor area (ft') 1089 ft2 c. N/A 7. Glass area & type a. Clear - single pane 75.0 ft2 — 13. Heating systems b. Clear - double pane 0.0 ft2 — a. Gas Hydronic Space & Water Hea c. Tinuother SC/SHGC - single pane 0.0 W d. Tintiother SC/SHGC - double pane 0.0 ft, b. N/A 8. I:loor types a. N/A c. N/A b. N/A c. N/A 14. Hot water systems 9. Wall types a. Natural Gas i a. Frame, Wood, Exterior R=1 1.0, 260.0 ft2 f b. Frame, Wood, Exterior R=11.0, 32.0 ft2 _ b. N/A c. Frame. Wood; Adjacent R=11.0, 208.0 112 _ d. Frame,.Wood. Exterior R=11.0. 225.0 ft2 _ c. Conservation credits e. NiA HR-Heat recovery, Solar 10. Ceiling types DHP-Dedicated heat pump) a. Under Attic R=30.0, 1089.0 ft2 _ 15. HVAC credits b. N/A CF-Ceiling fan, CV -Cross ventilation, c. N/A HF-Whole house fan, I I . Ducts PT -Programmable Thermostat. a. Sup: Unc. Ret: Unc. AH: Not In Attic Sup. R=6.0, 40.0 ft _ RB-Attic radiant barrier, b. N/A MZ-C-Multizone cooling, MZ-H-Multizone heating) I certify that this home has complied with the Florida Energy Efficiency Code For Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: Address of New Home: Date: City/FL Zip: Cap: 24.0 kBui/hr SEER: 10.00 Cap: 17.0 kBtu/hr _ RE: 0.77 Cap: 40.0 gallons _ EF: 0.66 NOTE: The home's estimated energy performance score is only available through the FLARES computer program. This is not a Building Energy Rating. Ifyour score is 80 or greater (or 86for a US EPA/DOE EnergyStarT"'designation), your home may qualify for energy efficiency mortgage (EEM) incentives ifyou obtain a Florida Energy Gauge Rating. Contact the Energy Gauge Hotline at 4071638-1492 or see the Energy Gauge web site at www.fsec.ucf edu for information and a list ofcertified Raters. For information about Florida's Energy Efficiency Code For Building Construction, contact the Department of Community Affairs at 8501487-1824. EnergyGauge® (Version: FLRCNA-200) Air System Sizing Summary for THREE BEDROOM UNIT TOP Project Name: WYNDHAM PLACE APTS 00199 10/15/00 Prepared by: KTD Consulting Engineers 09:14 PM Air System Information System Name THREE BEDROOM UNIT TOP Equipment Class SPLT AHU Number of Zones 1 System Type SZCAV Floor Area 1089.0 ft2 Sizing Calculation Information zind Space Suing i oMc)C:- Zone CFM Peak zone sensible load Calculation Months Jan to Dec Space CFM Coincident space loads Sizing Data Calculated Central Cooling Coil Sizing Data Total coil load 1.5 Tons Load occurs at Jul 1700 Sensible coil load 1.2 Tons OA DB / WB 92.3 175.6 OF Coil CFM at Jul 1700 835 CFM Entering DB / WB 77.1 166.6 OF Max possible CFM 835 CFM Leaving DB / WB 61.0 / 60.0 OF Design supply temp. 57.0 OF Coil ADP 59.2 OF ftZ/Ton 746.5 Bypass factor 0.100 BTU/hr/ft2 16.1 Resulting RH 58 % Water flow @ 10.0 OF rise gpm Zone T-stat Check 1 of 1 OK Central Heating Coil Sizing Data Max coil load 15051 BTU/hr Load occurs at Des Htg Coil CFM at Des Htg 835 CFM BTU/hr/ft2 13.8 Max possible CFM 835 CFM Ent. DB / Lvg DB 70.9 / 87.6 OF Water flow @ 20.0 OF drop gpm Supply Fan Sizing Data Actual max CFM at Jul 1600 835 CFM Fan motor BHP 0.00 BHP Standard CFM 832 CFM Fan motor kW 0.00 kW Actual max CFM/ft2 0.77 CFM/ft2 Fan static 0.00 in. wg. Outdoor Ventilation Air Data asigg ail-59v., CFM -- O CFM -:: CFM/person D`OU CFM/person CFM/ft2 0.00 CFM/ft2 Carrier Hourly Analysis Program v4.04 Page 17 Zone Sizing Summary for THREE BEDROOM UNITTOP ProjectlName: WYNDHAM PLACE APTS 00199 10/15/00 Prepared by: KTD Consulting Engineers 09:14 PM Sizing Calculation Information Zone and Space Sizing Method: Zone CFM Peak zone sensible load Calculation Months Jan to Dec Space CFM Coincident space loads Sizing Data Calculated Zone Sizing Data Maximum Design Minimum Time Maximum Cooling, Air Air, of Heating Sensible Flow Flow Peak Load Zone Name MBH); (CFM) CFM): Loads (MBH) Zone 1 16.2' 835 8351 Jul 160d 15.3' Zone Terminal Sizing Data rnunal scimj CY;ta r_ ..;uirF:c' for lhk sySl;,n, Space Loads and Airflows Cooling, Time; Air, Heating Zone Name / Sensible, of Flow, Load: Space Name Mult (MBH)i Load (CFM) MBH)j Zone 1 THREE BEDRM UNIT TOP 1 16.2: Jul 1600, 835 15.3, Carrier Hourly Analysis Program v4.04 Page 18 F-T- Air System Design Load -Summary -for -THREE BEDROOM -UNIT -TOP ProjectName: WYNDHAM PLACE APTS 00199 10/15/00 Prepared by: KTD Consulting Engineers 09:14 PM DESIGN COOLING DESIGN HEATING COOLING DATA AT Jul iroo HEATING -DATA AT DES HTG . COOLING OA DB WB 92.3 *F 75.6 *F HEATING OA DB I WB 37.0 *F 131.1 F Seris-ib-i-e Lat - ent Sensible Latent ZONE LOADS Details (BTU/hr) BTU/hr). Details (BTU/hr), BTU/hr) Solar Loads 75 ft2 4-864 Wall Transmission 517 ft2 1651 517 ft2 1314 Roof Transmission 1089 ft2 2046 1089 ft2 1111 Glass Transmission 75 ft2 1406 75 ft2 3224 Skylight Transmission 0 f12 0 0 ft2 0 Door Transmission 0 ft2 0 0 ft2 0 Floor Transmission 0 ftl: 0 0 f12 0: Partitions 208 ft2 1587 208 f12 3640; Ceiling 0 ft2 0 0 ft2 0 Overhead Lighting 0 W 0 0 0 Task Lighting 0 W 0 0 0 Electric Equipment 0 W 0 0 0 People 4 980 820 0 0 0 Infiltration 2032 1880 0 6015 0 Miscellaneous 1600 300; 0 0 Safety Factor 0%/0% 0: 0i 0% 0 0 Total Zone Loads 16166 3000' 15302* 0 Zone Conditioning 14505, 3000 15051 0 Plenum Wall Load 0% 0 0 0 Plenum Roof Load 0% 0 0 0 Plenum Lighting Load 0% 0 0 0 Return Fan Load 835 CFM 0 835 CFM 0: Ventilation Load 0 CFM 0 0 0 CFM 0 0 Supply Fan Load 835 CFM 0 835 CFM 0 Space Fan Coil Fans 0: 0 Duct Heat Gain / Loss 0% 0 0% 0: Total System Loads 14505 0003000 15051 0 Central Cooling Coil 14505 3000 0 0 Central Heating Cbil Oi 15051 T6taf C-6-naffifi-o-n-jn'g--- 14505i 0 Key: Positive -vallues'ane clg'loads Positive values are htg loads Negative values are htg loads Negative values are cIg loads Carrier Hourly Analyis-Program V4704 Page-19 Space Design Load Summary for THREE BEDROOM UNIT TOP Projectr'"Name: WYNDHAM PLACE APTS 00199 10/15/00 Prepared by: KTD Consulting Engineers 09:14 PM TABLE 1.1.A. COMPONENT LOADS FOR SPACE -"-THREE BEDRM UNIT TOP" INZONE -Zone 1 " 1. DESIGNCOOLING DESIGN HEATING COOLING DATA AT Jul 1600 HEATING DATA AT DES HTG OADB/ WB 93.5°F/75.9°F IOADB/WB 37.0°F/31.1 °F OCCUPIED T-STAT 75.0 °F OCCUPIED T-STAT 72.0 °F Sensible Latent i Sensible Latent SPACE LOADS Details; (BTU/hr)' BTU1hr)1 Details (BTU/hr)! BTU/hr) Solar Loads 76 ft--4621 1 75 ft2' - Wall Transmission 517 .ft2 14951 517 ft2 1314 Roof Transmission 1089 ft21 2194 1089 f42' 1111 Glass Transmission 75 ft21 1463 75 ft2 3224 Skylight Transmission 0 ft2' 0 0 ff2' & Door Transmission 0 ft21 0 0 ft20 Floor Transmission 0 ft2' 6 0 ft2' 0' Partitions 208 ft2 1652 208 ft2 3640 Ceiling 0 ft2 0 0 ft2' 0 Overhead Lighting 0 W' 0 0i 0 Task Lighting 0 W', 0 01 0' Electric Equipment 0 W' 0 0 People 4980 820 0' OI 0 Infiltration 2168 1782' 60151 0 Miscellaneous 1600 3001 - 0 i 0 Safety factor 0% / 0% 0 0! 0%, 0 0 Total Zone Loads 16173 2902 15302 0 TABLE 1. 1.13. ENVELOPE LOADS FOR SPACE " THREE'BEDRM UNIT TOP " IN ZONE " Zone 1 " COOLING COOLING HEATING Area U- Value Shade j TRANS SOLAR! TRANS ft2)' (BTU/ hr/ft2/F)'; Coeff.', (BTU/hr)1 (BTU/hr)'; BTU/hr) VY EXPG URE --------------- WALL 2601 0.0731 995' - 661 WINDOW 1 30 1.228 0.916! 585 2144 1289 WINDOW 2 30i 1.228 0.916: 585 2144 1289 EXPOSURE WALL - 321- - 0.073' 69! - 81 N EXPOSURE 3 WALL 2251 0 073 I 431, _; 572 WINDOW 1..__ - 151 1.228 0.916; - - -2931- -333i 645 H EXPOSURE ROOF 1089 0.029! 2194I 1111 Carrier Hourly Analysis Program v404 - - - Page 20 Wheule Building Performance Method for Commercial Buildings Form 40OA-97 ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs FLA/COM-97 Version 2.2 PROJECT NAME_WYNDHAM PLACE CLUBHOUSE ADDRESS. - OWNER: _ AGENT: BUILDING TYPE: _Service Establishments_ CONSTRUCTION CONDITION: New construction DESIGN COMPLETION: _Finished Building CONDITIONED FLOOR AREA: 4308 MAX. TONNAGE OF.,EQUIPMENT PER SYSTEM: COMPLIANCE CALCULATION: METHOD A DESIGN A. WHOLE BUILDING 70.01 PRESCRIPTIVE REQUIREMENTS: LIGHTING PERMITTING OFFICE: Sanford CLIMATE ZONE: 5 PERMIT NO: _ JURISDICTION N0: 691500 NUMBER OF ZONES 3 6 CRITERIA RESULT 100.00 PASSES LIGHTING CONTROL REQUIREMENTS PASSES HVAC EQUIPMENT COOLING.EQUIPMENT 1. SEER" 10.00 10.00 PASSES. 2. SEER 10.00 10.00 PASSES 3. SEER 10.00 10.00 PASSES HEATING EQUIPMENT 1. Et 1.00 N/A 2., Et 1.00 N/A 3. Et 1.00 N/A AIR DISTRIBUTION SYSTEM INSULATION REQUIREMENTS, 1. Unconditioned Space - 6.00 4.20 PASSES, 2: Unconditioned Space 6.00 4.20 PASSES 3. Unconditioned Space 6.00 4.20 PASSES REHEAT SYSTEM TYPES USED ELECTRICAL SYSTEM WATER HEATING EQUIPMENT 1. Et 0.95 0.78 SL 0.00 0.03 PASSES PIPING INSULATION REQUIREMENTS 1. Non -Circulating 1.00 1.00 PASSES COMPLIANCE CERTIFICATION: I hereby c;ert'ifv that the plans and Review of the plans and specifica- specificatiTr ons-coeredrby this calcu- tions covered by this calculation lation a=re-1 ,.compliance with the indicates compliance with the Florida FnergMf_'cency-Code. Florida Energy Efficiency Code. PREPARED ' BY. Before construction is completed, DATE: I hereby certify that this building is in compliance with the Florida Energy Efficiency Code. OWNER/AGENT: DATE: this building will be inspected for compliance in accordance with Section 553.908, Flo r tutes. BUILDING OFFICIAL: / DATE: C - S - I hereby certify(*) that the system design is in compliance with the Florida Ener Efficienc CodegYY SYSTEM DESIGNER ARCHITECT REGISTRATION/STATE MECHANICAL: q .. ` Lr PLUMBING _ N . 15 -,-(r, ELECTRICAL: S 0 D Lf E ~L. LIGHTING Signature is required.where Florida law requires design to be performed by registered design professionals. Typed names and registration numbers may be used where all relevant information is contained on signed/sealed plans. BUILDING ENVELOPE SYSTEMS COMPLIANCE CHECK 401------- GLAZING --ZONE 1 v- Elevation Type U SC VLT Shading Area(Sgft) North Commercial 1.31 1.0 1.0 None 12 East Commercial 1:31 1.0 1.0 None, 18 East Commercial, 1.31 1.0 1.0 Continuous Ove 108 South Commercial, 1.31 1.0 1.0 Continuous Ove 108 West Commercial 1.31 1.0 1.0 None 36 West Commercial 1.31 1.0 1.0 None 10 Total Glass Area in Zone 1 292 401.------GLAZING--ZONE 2------------------------------------------------ v- Elevation Type U SC VLT Shading Area(Sgft) i West Commercial 1.31 1.0 1.0 Continuous Ove 36 North Commercial 1.31 1.0 1.0 Continuous Ove 18 West Commercial 1.31 1.0 1.0 None 48 West Commercial 1.31 1.0 1.0 None 72 Total Glass Area in Zone 2 174 401------- GLAZING --ZONE 3-------------------------------------------------- v- Elevation Type U SC VLT Shading Area(Sgft) East Commercial 1.31 1.0 1.0 Continuous Ove 30 North Commercial 1.31 1.0 1.0 Continuous Ove 60 South Commercial 1.31 1.0 1.0 None 30 North Commercial 1.31 1.0 1.0 Continuous Ove 96 North Commercial 1.31 1.0 1.0 Continuous Ove 24 South Commercial 1.31 1.0 1.0 Continuous Ove 96 South Commercial 1.31 1.0 1.0 Continuous Ove 8 South Commercial 1.31, 1.0 1.0 Continuous Ove 12 North_.___ . _..:_.._.._Commercial 1.31 1._0 .._ 1.0 Continuous Ove 4.8.._-_....._._.. North Commercial.. 1.31 1.,0-- 1.0 Continuous,Ove 4,8 North Commercial 1.31 1.0 1.0 Continuous Ove 12 South Commercial lAl 1.0 1.0 Continuous Ove 120 South Commercial 1.31 1.0 1.0 None 30 South Commercial 1.31 1.0 1.0 None 18 Total Glass Areain"Zone 3 632 Total Glass Area 1098 402------- WALLS --ZONE 1-------------------------------------------------- Elevation Type U Insul R Gross(Sgft) North 3/4"Stco/2x4@16"oc+RllBatt/%"Gyp 0.080 11 160 East 3/4"Stco/2x4@16"oc+RllBatt/%"Gyp 0.080 11 160 West 3/4"Stco/2x4@16"oc+RllBatt/%"Gyp 0.08'0 11 100 East 3/4"Stco/2x4@16"oc+RllBatt/%"Gyp 0.080 11 70 West 3/4"Stco/2x4@16"oc+RllBatt/%"Gyp 0.080 11 75 North 3/4"Stco/2x4@16"oc+RllBatt/%"Gyp 0.080 11 20 East 3/4"Stco/2x4@16"o.c+RllBatt/%"Gyp 0.080., 11 345' South 3/4"Stco/2x4@16"oc+RllBatt/3"Gyp. 0.08.0 11 540 West 3/4"Stco/2x4.@16"oc+RllBatt./%"Gyp 0.080 11 345 Total Wall Area in Zone 1 1815 402------- WALLS --ZONE 2--7----------------------------------.----------- Elevation Type U Insul R Gross(Sgft) North 3/4"Stco/2x4@16"oc+RllBatt/35"Gyp 0.080 11 130 West 3/4"Stco/2x4@16"oc+RllBatt/5"Gyp 0.080 11 160 North 3/4"Stco/2x4@16."oc+RllBatt/3"Gyp 0.080 11 160 East 3/4"Stco/2x4@16"oc+RllBatt/"Gyp 0.080 11 100 East 3/41.'Stco/2x4@16".oc+RllBatt/%"Gyp 0.080 11 85 North 3/4"Stco/2x4@16"oc+RllBatt/"Gyp 0.08'0 11 70 West 3/4"Stco/2x4@16"oc+RllBatt/%"Gyp 0.080 11 170 South 3/4"Stco/2x4@16"oc+RllBatt/%"Gyp 0.080 11 190 Total Wall Area in Zone 2 = 1065 402------- WALLS -=ZONE 3------------------------------------------------- Elevation Type U Insul R Gross(Sgft) West 3/4"Stco/2x4@16"oc+RllBatt/3"Gyp 0.080 11 10.0 South 3/4"Stco/2x4@16"oc+RllBatt/3"Gyp 0.08,0 11 40 East 3/4"Stco/2x4@16"oc+RllBatt/M"Gyp 0.080 11 150 North 3/4"Stco/2x4@16"oc+RllBatt/%"Gyp 0.080 11 150 South 3/4"Stco/2x4@16"oc+RllBatt/%"Gyp 0.080 11 150 North 3/4"Stco/2x4@16"oc+RllBatt/%"Gyp 0.080 11 200I North 3/4"Stco/2x4@161!oc+RllBatt/%"Gyp 0.080 11 330 East 3/4"Stco/2x4@16"oc+RllBatt/%"Gyp 0.080 11 260 South 3/4"Stco/2x4@16"oc+RllBatt/%"Gyp 0.080 11 340 West 3/4"Stco/2x4a16"oc+RllBatt/M"Gyp 0.080 11 180 South 3/4"Saco/2x4@16"oc+R11:Batt/4"Gyp 0.020 11 210 Total Wall Area in Zone 3 = 2110 Total Gross Wall Area = 4990 403------- DOORS --ZONE 1------------------------------------------------ Elevation Type U Area (Sgft) i North No doors 0.00 01 Total Door Area in Zone 1 = 0 403.------DOORS-.-ZONE 2------------------------------------------------ Elevation Type U Area(Sgft) North No doors 0.00 0 Total -Door Area in Zone- 2 .= 0..1 6.4'03.----:--DOORS--ZONE 3_------------- .------- ------ ----------- --- Elevation Type U Area(Sgft) North No doors 0.00 0 Total Door Area in Zone 3'= 0 Total Door Area = 0 404------- ROOFS --ZONE 1------------------------------- -------------------- Type Color U Insul R Area.(Sgft) Shngl/1/2"WD Deck/WD Truss/9" B Dark 0.027 30 144.1 Total Roof Area in Zone 1 = 1441 404.------ROOFS--ZONE 2------------------------------------------------ Type Color U Insul R Area(Sgft) Shngl/1/2"WD Deck/WD Truss/9" B Dark 0.027 30 844 Total Roof Area in Zone 2 = 844 404------- ROOFS --ZONE 3------------------------------------------------ Type Color U Insul R Area(Sgft) Shn9l/1/2"WD Deck/WD Truss/9" B Dark 0.027 30 2150 Total Roof Area in Zone 3 = 2150 Total Roof Area = 4435 405------- FLOORS -ZONE 1------------------------------------------------ Type Insul R Area(Sgft) r _- Slab or, Grade/Uninsulated 0 1314 Total Floor Area in Zone 1 1314 405. FLOORS -ZONE 2------------------------------------------------ Type Insul R Area(Sgft) Slab on Grade/Uninsulated 0 844 Total Floor Area in Zone 2 844' 405.------FLOORS-ZONE 3 ------------------------------------------------ Type Instil R Area(Sgft) Slab on Grade/Uninsulated 0 2150 Total Floor Area in Zone 3 2150. Total Floor Area 4308 406------- INFILTRATION -------------------------------------------------- Infiltration Criteria in 406.1.ABCD have been met. CHECK,I I MECHANICAL SYSTEMS CHECK HVAC load sizing has 1_i-xbeenperformed. (407.1.ABCD) 407.------COOLING SYSTEMS----------------------------------------------- Type No Efficiency IPLV Tons 1. Split System 1 10 0 5.00 2. Split System 1 10 0 2.50 3. Split System 1 10 0 5.00 408.------HEATING SYSTEMS----------------------------------------------- Type No Efficiency BTU/hr 1. Electric Resistance 1 1 51195 2. Electric Resistance 1 1 17065 3. El-ectric Resistance 1 1 68260 40,9..- 7VENTILATION----------------------------- Ventilation Criteria in 409.1.ABCD have been met. ICHECK," 410------ AIR DISTRIBUTION SYSTEM---------------------------------------- CHECK Duct sizing and design have been performed._(410.1.ABCD) AHU Type Duct Location R-value 1. Air Conditioners Unconditioned Space 6.0 2. Air Conditioners Unconditioned Space 6.0 3. Air Conditioners Unconditioned Space 6.0 CHECK I- Testing and balancing will be performed. (410.1.ABCD) t/ 411---/- AND PIPING ZONE --------------------------------------------- Basic prescriptive requirements in 411.1.ABCD have been met. PLUMBING SYSTEMS 411------ PUMPS AND PIPING -ZONE 1--------------------------------------- --- Type R-value/in Diameter Thickness 1. Non -Circulating 4 .75 1 411.-----PUMPS AND PIPING -ZONE 2--------------------------------------- --- Tyke R-value/in Diameter Thickness 1. Non -Circulating 0 0 0 411.-----PUMPS AND PIPING -ZONE 3 ---------------------------------------- Type R-value/in Diameter Thickness 1. Non -Circulating 0 0 0 412.-----WATER HEATING SYSTEMS -ZONE 1 ---------------------------------- Type Efficiency StandbyLoss InputRate Gallons 1. > 75,000 Btuh 95 0 0 75 412.-----WATER HEATING SYSTEMS -ZONE 2 ---------------------------------- Type Efficiency StandbyLoss InputRate Gallons 412.-----WATER HEATING SYSTEMS -ZONE 3---------------------------------- Type Efficiency StandbyLoss InputRate Gallons ELECTRICAL SYSTEMS CHECK 413.-----ELECTRICAL POWER DISTRIBUTION---------------------------- Metering criteria in 413.1.ABCD have been met. Z 414.-----MOTORS Motor efficiencies in 414.1.ABCD have been met. 415.-----LIGHTING SYSTEMS -ZONE 1 ---------------------------------------- Space Type No Control Type 1 No Control Type 2 No Watts Area(Sgft) Washing 1 On/Off 2 None 0 204 234 Control Ro 1 On/Off 2 None 0 13.6 ill Toilet and 1 On/Off 2 None 0 40 52 Toilet and 1 On/Off 2 None 0 40 69 Multi -fun. 1 On/Off 2 None 0 1280 848' Total Watts for Zone 1 = 1700 Total Area for Zone 1 = 131-4, 415.-----LIGHTING SYSTEMS -ZONE 2 --------------------------------------- Space Type No Control Type 1 No Control Type 2 No Watts Area(Sgft) Reading, T 1 On/Off _ 2 None 0 208 208 Toilet and 1 On/Off 2 On/Off 2 132 166 Toilet and 1 On/Off - 2 On/Off 2 132 142 General Ex 1 On/Off 2 None 0 640 328 Total Watts for Zone 2 = 1112 Total Area for Zone 2 = 844 415------ LIGHTING SYSTEMS -ZONE 3 --------------------------------------- Space Type No Control Type 1 No Control Type 2 No Watts Area(Sgft) Reading, T 1 On/Off 2 None 0 320 148 Reading, T 1 On/Off 2 None 0 208 226 Reading, T 1 On/Off 2 None 0 208 168 Reading, T 1 On/Off 2 None 0 416 371 Reception 1 On/Off 2 None 0 312 424 Reading Ar 1 On/Off 2 On/Off 2 780 813 Total Watts for Zone 3 = 2244 Total Area for Zone 3 = 2150 Total Watts 5056 Total Area 4308 Lighting criteria in 415.1.ABCD have been met. CHECK 7 --- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 16' Operation/maintenance manual will be provided to owner.(102.1)