Loading...
100 N Elliott Ave - BR08-001536 (REROOF) DOCUMENTSCITY OF SANFORD,PERMIT APPLICATION Application # 1_53(o Submittal Date: 5 Q a-9 Job Addrg:-:" 1v1 O // Value of Work: $ k?/, 9/ y Parcel ID: L -19-31-6 O V ' 19,60D -1)0g?D Zoning: Historic District: Description of Work: Pr roof ),i/A 1 ,r "irlYJ i`1% f W Square Footage: 2:7,3 Permit Type: Building Electrical Mechanical Plumbing Fire Sprinkler/Alarm " Pool Sign Electrical: New Service- # of AMPS Addition/Alteration Change of Service Temporary Pole Mechanical: Residential Non -Residential Replacement New (Duct Layout & Energy Calc. Required) Plumbing/ New Commercial: # of Fixtures # of Water & Sewer Lines # of Gas Lines Plumbing/New Residential: # of ater Closets Plumbing Repair - Residential Commercial Occupancy Type: Residential Commercial Industrial Occupancy Use Group(s): Construction Type: oa7 # of Stories: # of Dwelling Units: Flood Zone: (FEMA form required) Pro ert Owner .............................................. ............................. ..... ............. J L .- p y : 61>4)"J, C/IAr/fs Lllen Contractor: JAl fr3 Al Address: Q / Alp" Address: %-25—1 i !Y/i7clfi c J t a,iT1C% r/c/t' 1 j ssz 4 ry 3.2707 Phone: X7.967.970b E-mail: i •C o,rt7flleg&1f ja/Z'lid A/!lf/ iG Phone: G,7 Y% S OState License Number: Bonding Company: Mortgage Lender: Address Architect/Engineer: Address Address: Plan Review Contact Person: Phone: Fax: Phone: Fax: E-mail: Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, and AIR CONDITIONERS, etc. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the proppftyof Signature of Owner/Agent Date Print Owner/Agent's Name Signature of Notary -State of Florida Date Owner/Agent is Personally Known to Me or Produced ID APPROVALS: ZONING: UTIL. Special Conditions: Rev 07.07 FD: S e req ements of Florida Lien Law, FS 713. Contractor/Agent Date tor/Agent's Name - t puq Notary Public State of Flonda Holly Marie Capponi Q My Commission DD464199 dor n° ,Exoires 08/21/2009 Contractor/Agent is / Personally Known to Me or Produced ID ENG: " BLDG: Phone: 9&7— 9g® This letter is to give Majestyk Construction Company, Inc.'s representative permission to act as your agent when applying for your roofing permit. Please read the statement below and sign before a Florida Notary Public. I, F u ti , give Majestyk Construction Company, Inc.'s agent or James S. Rowlandpermission to act as my agent, and to sign my name and do all things necessary when applying for my roofing permit. clu-0 V -\"20Q -L- r Signature Date STATE OF FhtMM COUNTY OF The foregoing instrument was acknowledged before me this day of Y \ 120,0% by CC) \k-;,(2" Q C h who is o personally known or Nproduced \ l_ as identification. Signature of Notary•a0•°`°Btld°B•ees Name of Notary Typed, Stamped or Prin d `M 1 C)WS o`° SSP M JOy My Commission Expires: s a ` L \ ee+ Q'fiLM •Fa'A. ti t OTA,y •;Z lW m (P UST21, F G 1251 Seminola Blvd., Suite 100 • Casselberry, FL 32707 'a9q®fi WASOk10 ® e° B) 407-478-5250 • (F) 407-478-8831 AFFIDAVIT REGARDING ROOF DRY -IN AND FLASHING INSPECTIONS Company: Al f;S//t [t n1%Y t/ra a L 1 License CC C 7) &W L'A 16 Z 7270% Project Information Owner: C-0 F, Permit #: name ,,/// / o p% d j G# 1 Y f },/RIfa/'O' Subdivision: address Di-gd 7-qW b Lot#: Lo f f phone cy, p 1 , affiant, hereby affirm that I am the duly licensed contractor of record for the above referenced permit, that all the foregoing information is true and accurate, and that the dry in, flashings at the above referenced address or lot has been installed in accordance with the applicable codes and standards. Contractor: /bw I 4 signattarto / h/lAn l printed name STATE OF FLORIDA COUNTY OF This instrument was acknowledged before me this day of _ , LOO by the referenced individual V3 whp acknowl ged that he/she is aabove , duly licensed contractor wi , and who acknowledged that he/she was authorized to execute s dot ent. He/she is etherpersonally known to me or produced WITNESS my hand and seal this c,2,ti r , : M4 pub tate of Flonda aQ ; arie Capponi QmmissionDD4641N. o 06=121i2009 Seminole County Property Appraiser Get Information by Parcel Number Paget of 2 http://www.scpafl.org/web/re—web.seminole__county title?PARCEL=30193150406000080... 4/16/2008 112 L DAVID JOH.nsom, CFA, Asn 42 7.fl- 1 w Q1.; 9 PROPERTY, I 13 E later ys. a14 a 91ra14.0 f APPRAISER A _ sEhJINQLE COUNTY FL 1.01 8.0 a E li I tDI E. FIRsT s -r SANFORD, FL 32771-146433 ILI ) 1.A2 j 8.A,gt10 2 1Q 407-665-7506 a 3.0 11 12 LI 2008 WORKING VALUE SUMMARY Amendment 1 impact not reflected. GENERAL Value Method: Market Parcel Id: 30-19-31-504-0600-0080 Number of Buildings: 1 Owner: GOEHRIG CHARLES & COLLEN F Depreciated Bldg Value: $97,908 Mailing Address: 100 N ELLIOTT AVE Depreciated EXFT Value: $17,199 City,State,ZipCode: SANFORD FL 32771 Land Value (Market): $56,300 Property Address: 100 ELLIOTT AVE N SANFORD 32771 Land Value Ag: $0 Subdivision Name: MAYFAIR Just/Market Value: $171,407 Tax District: S1-SANFORD Assessed Value (SOH): $122,483 Exemptions: 00 -HOMESTEAD (1999) Exempt Value: $25,000 Dor: 01 -SINGLE FAMILY Taxable Value: $97,483 Tax Estimator Portability Calculator SALES Deed Date Book Page Amount Vac/Imp Qualified CORRECTIVE DEED 11/2002 04582 1350 $100 Improved No 2007 VALUE SUMMARY ADMINISTRATIVE 12/2001 04404 1272 $100 Improved No Tax Amount(without SOH): $2,835 DEED 2007 Tax Bill Amount. $1,752 PROBATE RECORDS 04/2002 04375 0599 $100 Improved No Save Our Homes (SOH) Savings: $1,083 CORRECTIVE DEED 07/1999 03690 1690 $100 Improved No 2007 Taxable Value: $93,916 WARRANTY DEED 11/1998 03547 1970 $177,000 Improved No DOES NOT INCLUDE NON -AD VALOREM WARRANTY DEED 03/1979 01215 1392 $70,000 Improved Yes ASSESSMENTS WARRANTY DEED 01/1973 00984 0314 $38,000 Improved Yes Find Comparable Sales within this Subdivision LAND LEGAL DESCRIPTION Land Assess Method Frontage Depth Land Unit Land Units Price Value PLATS: Pick... FRONT FOOT & 96 145 .000 430.00 $41,693 LEG LOTS 8 & B (LESS S 43 FT OF W 40 FT OF DEPTH LOT 8) BLK 6 MAYFAIR FRONT FOOT & 43 94 .000 430.00 $14,607 PB 3 PG 35 DEPTH BUILDING INFORMATION Bid Year Base Gross Living Est. Cost Bid Type Fixtures Ext Wall Bid Value Num Bit SF SF SF New Building 1 SINGLE 1930 6 1,782 3,390 3,010 WD/STUCCO $97,908 $244,770 Sketch FAMILY FINISH Appendage I Sqft ENCLOSED PORCH FINISHED / 56 Appendage I Sqft GARAGE UNFINISHED / 380 Appendage / Sqft ENCLOSED PORCH FINISHED / 378 Appendage / Sqft UPPER STORY FINISHED / 794 NOTE: Appendage Codes included in Living Area: Base, Upper Story Base, Upper Story Finished, Apartment, Enclosed Porch Finished, Base Semi Finshed http://www.scpafl.org/web/re—web.seminole__county title?PARCEL=30193150406000080... 4/16/2008 W Seminole County Property Appraiser Get Information by Parcel Number. Page 2 of 2 Permits EXTRA FEATURE Description Year Bit Units EXFT Value Est. Cost New POOL GUNITE 1979 450 $3,600 9,000 SCREEN ENCLOSURE 2002 2,859 $4,576 5,718 ALUM PORCH W/CONC FL 2002 305 $1,587 1,983 STAMPED CONCRETE PATIO 2002 705 $3,596 4,230 WATER FEATURE 2002 2 $3,400 4,000 ELECTRIC HEATER 2002 1 $440 1,100 NOTE: Assessed values shown are NOT certified values and therefore are subject to change before being finalized for ad valorem tax purposes. If you recently purchased a homesteaded property your next year's property tax will be based on JusUMarket value. http://www. scpafl. org/web/re_web. seminole_county_title?PARCEL=3 0193150406000080... 4/16/2008 M I A M I•DADE BUILDING CODE COMPLIANCE OFFICE (BCCO) PRODUCT CONTROL DIVISION MIAMI-DADE COUNTY, FLORIDA METRO-DADE FLAGLER BUILDING 140 WEST FLAGLER STREET, SUITE 1603 MIAMI, FLORIDA 33130-1563 305) 375-2901 FAX (305) 375-2908 NOTICE OF ACCEPTANCE (NOA) Gerard Roofing Technologies 1100 Chase Road, Suite 100 Mesquite TX 75149 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed by Miami -Dade County Product Control Division and accepted by the Board of Rules and Appeals (BORA) to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Division (In Miami Dade County) and/or the AHJ (in areas other than Miami. Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the experise of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BORA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Division that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code and the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Gerard Tile, Shake, Canyon Shake, Barrel Vault and NB Tile LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job*site at the request of the Building Official. This revises NOA# 06-0420.05 and consists of pages 1 through 11. The submitted documentation was reviewed by Alex Tigera. NOA #: 06-1114.05 Expiration Date: 08/09/11 Approval Date: 01/11/07 Page 1 of 11 ROOFING SYSTEM APPROVAL: Category. Roofing Sub -Category: Metal, Panels (Non -Structural) Material: Steel Deck Tyne: Wood Maximum Design Pressure -159.25 psf TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: NOA #: 06-1114.05 Expiration Date: 08/09/11 Approval Date: 01/11/07 Page 2 of 11 Test Product Product Dimensions Specifications Description Gerard Tile Length = 15 '/2" TAS 110 Corrosion resistant, galvalume, Width = 45 3/4" preformed, coated with acrylic resin Thickness: .0195" TAS 125 imbedded with mineral granules, metal .panels simulating a tile profile. Gerard Shake Length = 15 /2" TAS 110 Corrosion resistant, coated, Width = 44 3/4" preformed, metal panels simulating Thickness: .0195" TAS 125 a shake profile. Gerard Canyon Length = 16'/2" TAS 110 Corrosion resistant, coated, Shake Width = 45" preformed, metal panels simulating Thickness: .0195" TAS 125 a shake profile. Gerard Barrel Vault Length = 15'/2" TAS 110 Corrosion resistant, coated, Width = 43 3/4" preformed, metal panels simulating Thickness: .0195" TAS 125 a barrel tile profile. Gerard NB Tile Length = 16" TAS 110 Corrosion resistant, coated, Width = 46" preformed, metal panels simulating Thickness: .0195" TAS 125 a tile profile. Trim Pieces Length: Varies TAS 110 Standard flashing and trim pieces. Width: Varies Corrosion resistance galvalume. NOA #: 06-1114.05 Expiration Date: 08/09/11 Approval Date: 01/11/07 Page 2 of 11 EVIDENCE SUBMITTED: Test Agency Test Identifier Underwriters Laboratories Inc 90NK5767 Center for Applied Engineering, Project No. 307064 Inc. MDC -126 Underwriters Laboratories Inc 98NK14487 Building Research Association of MTR 794 New Zeland Underwriters Laboratories, Inc. 90NK5767 Hurricane Test Laboratory, LLC. 0102-0603-05 Hurricane Test Laboratory, LLC. 0351-0119-06 aJ i, TCo o Test Name/Report Date Uplift Pressure Testing Sept. 1990 UL 1897 Wind Driven Rain April 1995 TAS 100 Fire Resistance May 1998 ASTM E 108 Salt Spray Sept. 1985 ASTM B 117 Accelerated Weathering Sept. 1990 ASTM G 23 TAS 125 06/08/05 TAS 125 02/01/06 NOA #: 06-1114.05 Expiration Date: 08/09/11 Approval Date: 01/11/07 Page 3 of 11 APPROVED SYSTEMS SYSTEM A-1: Gerard Tile, Shake, Canyon Shake, Barrel Vault, and NB Tile Deck Type: Wood, Non -insulated Slope Range: 2":12" or greater Maximum Uplift Pressure: The maximum allowable uplift pressure for System A-1 shall be —52.5 psf Deck Attachment: In accordance with applicable building code, but in no case shall it be less than # 8 x 1 1/z" long screws spaced 6" O.C. In reroofing, where the deck is less than19/ 32" thick (Minimum "/32") The above attachment method must be in addition to existing attachment. Underlayment: Minimum underlayment shall be: (1) A double layer of an ASTM D 226 Type I, , with a 19 -inch headlap; or (2) A single layer of an ASTM D 226, type II with a 4 -inch headlap; or (3) A single layer of an ASTM D 2626 coated base sheet with a 4 inch headlap. All endlaps shall be a minimum of 6 inches. Underlayment shall be fastened with corrosion resistant tin -caps and 11/4" annular nng-shank nails, spaced 6" o.c. at all laps and two staggered rows 12" o.c. in the field of the roll. Or, any Miami -Dade County Product Control Approved underlayment having a current NOA. Fire Barrier: Any approved Fire Barrier having a current NOA. For class A or B fire rating,installminimum 1/4" thick Georgia Pacific "Dens Deck" (with current NOA)or minimum 4mm thick Tritex, RockRoof (with current NOA) or 5/ 8""water resistance type X gypsum sheating with tretated core facer. Battens: Install minimum 2" x 2" wood battens over underlayment and fire barrier, running perpendicular to the roof slope, at a maximum spacing of 141/2" o.c.. Attach wood battens through deck to wood trusses spaced 24" o.c. fastened with 16d x 31/2" long nails. Valleys: Valley construction shall be in compliance with Roofing Aplication Standard RAS 133 and with the current published installation instruction and details in Gerard Roofing Installation Manual_ Metal Panels and Accessories: Install the "Gerard Tile, Shake, Canyon Shake, Barrel Vault, and NB Tile" and accessories in compliance with Gerard Roofing Technologies installation instructions and details in Gerard Roofing Installation Manual. Flashings, penetrations, valley construction and other details shall be constructed in compliance with Roofing Application Standard RAS 133. Panels fastened to battens with Approved nails driven into (lower) butt edges of upper course and. upper edge of adjacent lower course. A minimum of five Approved nails or #10 x 2" long wood screws for each Panel. NOA #: 06-1114.05 Expiration Date: 08/09/11 Approval Date: 01/11/07 Page 4 of 11 SYSTEM B-1: Gerard Tile, Shake, Canyon Shake, Barrel Vault, and NB Tile Deck Type: Wood, Non -insulated Slope Range: 2":12" or greater Maximum Uplift Pressure: The maximum allowable uplift pressure for System B-1 shall be —91.75 psf Deck Attachment: In accordance with applicable building code, but in no case shall it be less than # 8 x 1 1/z" long screws spaced 6" O.C..In reroofing, where the deck is less than19/32" thick (Minimum '5/32") The above attachment method must be in addition to existing attachment. Underlayment: Minimum underlayment shall be: (1) A double layer of an ASTM D 226 Type 1, with a 19 -inch headlap; or (2) A single layerof an ASTM D 226, type II with a 4 -inch headlap; .or (3) A single layer of an ASTM D 2626 coated base sheet with a 4 inch headlap. All endlaps shall be a minimum of 6 inches. Underlayment shall be fastened with corrosion resistant tin -caps and 11/4" annular ring -shank nails, spaced 6" o.c. at all laps and two staggered rows 12" o.c. in the field of the roll. Or, any Miami -Dade County Product Control Approved underlayment having a current NOA. Fire Barrier: Any approved Fire Barrier having a current NOA. For class A or B fire rating,install minimum 1/4" thick Georgia Pacific "Dens Deck" (with current NOA)or minimum 4mm thick Tritex, RockRoof (with current NOA) or5/ 8""water resistance type X gypsum sheating with tretated core facer. Battens: Install minimum 2" x 2" wood battens over underlayment and fire barrier, running perpendicular to the roof slope, ata maximum spacing of.141/2" o.c.. Attach wood battens through deck to wood trusses spaced 24" o.c. fastened with two 16d x 3 1/z" long nails. Valleys: Valley construction shall be in compliance with Roofing Aplication Standard, RAS 133 and with the current published installation instruction and details in Gerard Roofing Installation Manual. Metal Panels and Accessories: Install the ,"Gerard Tile, Shake, Canyon Shake, Barrel Vault, and NB Tile Shake" and accessories in compliance with Gerard Roofing Technologies installation instructions and details in Gerard Roofing Installation Manual. Flashings, penetrations, valley construction and other detailsshallbe constructed in compliance with Roofing Application Standard RAS 133. Panels' fastened to battens with Approved nails driven into (lower) butt edges of upper course and upper edge of adjacent lower course. A" minimum of five Approved nails or #10 x 2" long wood screws for each Panel. NOA #: 06-1114.05 Expiration Date: 08/09/11 Approval Date: 01/11/07 Page 5 of 11 SYSTEM C-1: Gerard Tile, Shake, Canyon Shake, Barrel Vault, and NB Tile Deck Type: Wood, Non -insulated Slope Range: 2":12" or greater Maximum Uplift Pressure: The maximum allowable uplift pressure for System C-1 shall be -159.25 psf Deck Attachment: In accordance with applicable building code, but in no case shall it be less than 8 x 1 1/z" long screws spaced 6" O.C. In reroofing, where the deck is less than19/32" thick (Minimum 15/32") The above attachment method must be in addition to existing attachment. Underlayment: Minimum underlayment shall be: (1) A double layer of an ASTM D 226 Type I, with a 19 -inch headlap; or (2) A single layer of an ASTM D 226, type 11 with a 4 -inch headlap; or (3) A single layer of an ASTM D 2626 coated base sheet with a 4 inch headlap. All endlaps shall be a minimum of 6 inches. Underlayment shall be fastened with corrosion resistant tin -caps and 1'/a" annular ring -shank nails, spaced 6" o.c. at all laps and two staggered rows 12" o.c. in the field of the roll. Or, any Miami -Dade County Product Control Approved underlayment having a current NOA. Fire Barrier: Any approved Fire Barrier having a current NOA. For class A or B fire rating,install minimum 1/4" thick Georgia Pacific "Dens Deck" (with current NOA)or minimum 4mm thick Tritex, RockRoof (with current NOA) or 5/ 8""waterresistance type X gypsum sheating with tretated core facer. Battens: Install minimum 2" x 2" wood battens over underlayment and fire barrier, running perpendicular to the roof slope, at a maximum spacing of 141/z" o.c.. Attach wood battens through deck to wood trusses spaced 24" o.c. fastened with two #8 x 3" long bugle phillips steel screws. Valleys: Valley construction shall be in compliance with the minimum requirements provided in Roofing Application Standard RAS 133. Metal Panels and Accessories: Install the " Gerard Tile, Shake, Canyon Shake, Barrel Vault, and NB Tile " and accessories in compliance with Gerard Roofing Technologies' current, published installation instructions and details. Flashings, penetrations, valley construction and other details shall be constructed in compliance with the minimum requirements provided in Roofing Application Standard RAS 133. Panels fastened to battens with approved 8d ring shank nails min. 2-3/8" long, driven into (lower) butt edges of upper course and upper edge of adjacent lower course. A minimum of eight approved nails or #10 x 2" long wood screws for each Panel. NOA #: 06-1114.05 Expiration Date: 08/09/11 Approval Date: 01/11/07 Page 6 of 11 SYSTEM LIMITATIONS 1. The maximum designed pressure listed herein shall be applicable to all roof pressure zones (i.e. field, perimeters, and comers). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones (i.e. perimeters, extended corners and corners). 2. All panels shall be permanently labeled with the manufacturer's name and/or logo, and the followingstatement: "Miami -Dade County Product Control Approved." 3. All products listed herein shall have a quality assurance audit in accordance with the Florida BuildingCodeandRule9B-72 of the Florida Administrative Code. O NOA #: 06-1114.05 Expiration Date: 08/09/11 Approval Date: 01/11/07 Page 7 of 11 4 4 DETAIL DRAWING: GERARD TILE GERARDSHAKE NOA #: 06-1114.05 Expiration Date: 08/09/11 Approval Date: 01/11/07 Page 8 of 1.1 Z, GERARD CANYON SHAKE GERARD BARREL VAULT o . NOA #: 06-1114.05 Expiration Date: 08/09/11 Approval Date: 01/11/07 Page 9 of 11 GERARD NB TILE o NOA #: 06-1114.05 Expiration Date: 08/09/11 Approval Date: 01/11/07 Page 10 of 11 GERARD SHADE CAP GERARD MISSION TRIM END OF THIS ACCEPTANCE o NOA #: 06-1114.05 K - Expiration Date: 08/09/11 Approval Date: 01/11/07 Page 11 of 11 LIMITED PO ER OF ATTORNEY Altamonte Springs, Casselberry, Lake Mary, Longwood, Sanford, Seminole County, Winter Springs Date: s-/ 07,0' ? I hereby name and appoint: i7mla an agent of. A'1' tJ1V11(- c117 V (Name of Company) to be my lawful attorney-in-fact to act for me to apply for, receipt for, sign for and do all things necessary to this appointment for (check only one option): i All permits and applications submitted by this contractor. The specific permit and application for work located at: Street Address) Expiration Date for This Limited Power of Attorney: License Holder Name: I 7 t3 U iawlxl7d State License Number: Signature of License Holder: STATE OF FLORIDA COUNTY O The foregoing instrument was acknowledged before me thi a of, 200 , by a XLoo I --t -o who personally own as Rev. 3/27/07) Permit # D 8 — ,j j (Q # NOTICE OF COMMENCEMENT The undersigned hereby gives notice that improvement will be made to certain real property and in accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement: 1. Legal Description of Property: Street Address if available: 2. General description of Improvement 3. a. Owner name and address: b. Interest in property: c Name and address of fee simple titleholder (if other than Owner): f b 4. a. Contractor name and address: b. Contractor's phone number: 5. a. Surety name and address: b. Surety's phone number: c. Amount of bond: 6. a. Lender name and address: b. Lender's phone number: ULHIIFILD CONI MARYANNE MORSE CLERK OF CIRCUIT DOURT SEMINO ' RD,RIDA WAY 5 20 his space reserved for recorder Lot Block FJ Unit # Bldg # []Lengthy legal attached Subdivision I Condominium: C. le.S Cr e Cr Gnll2en GL6Q.Lrr5 700 A) rt60± Ave SaA&4 GG 7277 MAJESTYK CONSTRUCTION ' rr cr. ;a Persons within the State of Florida designated by Owner upon whom notices or other documents may bers 7 a by Section 713.13(1)(a)7., Florida Statutes: < Name: Address: b. Phone number: 8. 8. a. In addition to himself or herself, the Owner designates b. Phone number of person or entity designated by owner 9. Expiration date of notice of commencement: r+ ro IU 9 I 0 o O • e asDpr avide co v w W Ln 0r- d to receive a copy of Lienors Notice per Section 713.13(1)(b), Florida the expiration date is 1 year from the date of recording unless a different date is specinea) WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART I, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY.. ANOTICEOFCOMMENCEMENTMUSTBERECORDEDANDPOSTEDONTHEJOBSITEBEFORETHEFIRSTINSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. Signature(s) of Owner(s) or Ow er(s)' uthorized OfficerlDirector/Partner/Manager By By c; V0 Print Name Print Name Q T Title/Office itle/Office STATE OF FL-9RfDAW 09;h% 09-11jr) COUNTY OFAI q YZVn The By was acknowled re me this 2 day of ldividually, or 11 as for 1 p Personally known, or rod uced the following type of identification: l Signature of Notary Pul Print No SE VERIFICATION PURSUANT TO SECTION 92.525 FLORIDA STATUI Under penalties of perjury, l declare that I have read the foregoing that the facts stated in it are true, to the best of my knowledge and be Signature(s of Owner(s) or wner s)' Authorized Officer/Director/I By 0, 0% ,,- g:\recording\forms\noc . notice of commencement revised 7.3.07.doc Seminole County Property Appraiser Get Information by Parcel Number Page 1 of 2 http://www.scpafl.org/web/re_web.seminole_county_title?parcel=30193150406000080&cp... 5/5/2008 DAVID JOHNSON, CFA, ASA 4 j5.0 7.0 ! r PROPERTY E "I ST a.a_ 9.0 114.0 APPRAISER A o SEMINDLE COUNTY `L.E 1.41 8.0 J 1101E. FIRST ST Ll 8•A' W 9 j 10 SANFORD, FL 32771-14b8 407-665-7506 4 11 2008 WORKING VALUE SUMMARY Amendment 1 impact not reflected GENERAL Value Method: Market Parcel Id: 30-19-31-504-0600-0080 Number of Buildings: 1 Owner: GOEHRIG CHARLES & COLLEN F Depreciated Bldg Value: $97,908 Mailing Address: 100 N ELLIOTT AVE Depreciated EXFT Value: $17,199 City,State,ZipCode: SANFORD FL 32771 Land Value (Market): $56,300 Property Address: 100 ELLIOTT AVE N SANFORD 32771 Land Value Ag: $0 Subdivision Name: MAYFAIR Just/Market Value., $171,407 Tax District: S1-SANFORD Assessed Value (SOH): $122,483 Exemptions: 00 -HOMESTEAD (1999) Exempt Value: $25,000 Dor: 01 -SINGLE FAMILY Taxable Value: $97,483 Tax Estimator Portability Calculator SALES Deed Date Book Page Amount Vac/Imp Qualified CORRECTIVE DEED 11/2002 04582 1350 $100 Improved No 2007 VALUE SUMMARY ADMINISTRATIVE 12/2001 04404 1272 $100 Improved No Tax Amount(without SOH): $2,835 DEED 2007 Tax Bill Amount: $1,752 PROBATE RECORDS 04/2002 04375 0599 $100 Improved No Save Our Homes (SOH) Savings: $1,083 CORRECTIVE DEED 07/1999 03690 1690 $100 Improved No 2007 Taxable Value: $93,916 WARRANTY DEED 11/1998 03547 1970 $177,000 Improved No DOES NOT INCLUDE NON -AD VALOREM WARRANTY DEED 03/1979 01215 1392 $70,000 Improved Yes ASSESSMENTS WARRANTY DEED 01/1973 00984 0314 $38,000 Improved Yes Find Comparable Sales within this Subdivision LAND LEGAL DESCRIPTION Land Assess Method Frontage Depth Land Unit Land Units Price Value PLATS: Pick... FRONT FOOT & 96 145 .000 430.00 $41,693 LEG LOTS 8 & B (LESS S 43 FT OF W 40 FT OF DEPTH LOT 8) BLK 6 MAYFAIR FRONT FOOT & 43 94 .000 430.00 $14,607 PB 3 PG 35 DEPTH BUILDING INFORMATION Bid Year Base Gross Living Est. Cost Bid Type Fixtures Ext Wall Bid Value Num Bit SF SF SF New Buildinci 1 SINGLE 1930 6 1,782 3,390 3,010 WD/STUCCO $97,908 $244,770 Sketch FAMILY FINISH Appendage / Sgft ENCLOSED PORCH FINISHED / 56 Appendage / Sgft GARAGE UNFINISHED / 380 Appendage / Sgft ENCLOSED PORCH FINISHED / 378 Appendage / Sgft UPPER STORY FINISHED / 794 NOTE: Appendage Codes included in Living Area: Base, Upper Story Base, Upper Story Finished, Apartment, Enclosed Porch Finished, Base Semi Finshed http://www.scpafl.org/web/re_web.seminole_county_title?parcel=30193150406000080&cp... 5/5/2008 Ok APPROVED SYSTEMS SYSTEM A-1: Gerard Tile, Shake, Canyon Shake, Barrel Vault, and NB Tile Deck Type: Wood, Non -insulated Slope Range: 2":12" or greater Maximum Uplift Pressure: The maximum allowable uplift pressure for System A-1 shall be —52.5 psf Deck Attachment: In accordance with applicable building code, but in no case shall it be less than # 8 x 1 1/2" long screws spaced 6" O.C. In reroofing, where the deck is less than 19/ 32" thick (Minimum 15/ 32") The above attachment method must be in addition to existing attachment. Underlayment: Minimum underlayment shall be: (1) A double layer of an ASTM D 226 Type I NOA #: 06-1114.05 Expiration Date: 08/09/11 Approval Date: 01/11/07 Page 4 of 11 with a 19 -inch headlap; or (2) A single layer of an ASTM D 226, type H with a 47inch headlap; or (3) A single layer of an ASTM D 2626 coated base sheet with a 4 inch headlap. All endlaps shall be a minimum of 6 inches. Underlayment shall be fastened with corrosion resistant tin -caps and 11/4" annular ring -shank nails, spaced 6" o.c. at all laps and two staggered rows 12" o.c. in the field of the roll. Or, any Miami -Dade County Product Control Approved underlayment having a current NOA. Fire Barrier: Any approved Fire Barrier having a current NOA. For class A or B fire rating,install minimum 1/4" thick Georgia Pacific "Dens Deck" (with current NOA)or minimum 4mm thick Tritex, RockRoof (with current NOA) or 5/ 8""water resistance type X gypsum shearing with tretated core facer. Battens: Install minimum 2" x 2" wood battens over underlayment and fire barrier, running perpendicular to the roof slope, at a maximum spacing of 141/2" o.c.. Attach wood battens through deck to wood trusses spaced 24" o.c. fastened with 16d x 3.1/2" long nails. Valleys: Valley construction shall be in compliance with Roofing Aplication Standard RAS 133 and with the current published installation instruction and details in Gerard Roofing Installation Manual. Metal Panels and Accessories: Install the "Gerard Tile, Shake, Canyon Shake, Barrel Vault, and NB Tile" and accessories in compliance with Gerard Roofing Technologies installation instructions and details in Gerard Roofing Installation Manual. Flashings, penetrations, valley construction and other details shall be constructed in compliance with Roofing Application Standard RAS 133. Panels fastened to battens with Approved nails driven into (lower) butt edges of upper course and upper edge of adjacent lower course. A minimum of five Approved nails or #10 x 2" long wood screws for each Panel. NOA #: 06-1114.05 Expiration Date: 08/09/11 Approval Date: 01/11/07 Page 4 of 11