Loading...
2905 Orlando Dr - BC96-003067 (1996) (BUILD NEW WAREHOUSE) (A) DOCUMENTSr ZONE DATE CONTRACTOR ADDRESS PHONE # % �f I 2q :::/ ?00 LOCATION �Q � /j d �'� q1-- Gee - OWNER ADDRESS PHONE # PLUMBINI ADDRESS PHONE # ELECTRICAL CONTRACTOR ADDRESS PHONE # MECHANICAL CONTRACTOR ADDRESS PHONE # MISCELLANEOUS CONTRACTOR ADDRESS SEPTIC TANK PERMIT NO, SOIL TEST REQUIREMENTS (_^) FINISHED FLOOR ELEVATION REQUIREMENTS (_) ARCHITECTURAL APPROVAL DATE: SUBDIVISION: PERMIT # C� _ -.. � LOT NO. JOB (tk�CT ca km,,.t BLOCK: COST $,`' �3 C/ 000 SECTION: SQUARE FEET: FEE $ STATE NO. 0C D� 6 70 FEE $ -37 FEE $ FEE $ MODEL: OCCUPANCY CLASS: INSPECTIONS I TYPE DATE OK REJECT BY 2® FEE $ ENERGY SECT. EPI:._ _T r Phi c 661, k-, �C��I�,�(r, -4�� ,_�. �-w�r �.�; -ill. ��� /l,1 i� ���, ,PI�/'�t�►; f CERTIFICATE OF OCCUPA N : Y ISSUED # r�� DATE: FINAL DATE A�4 �n Y �:.:, . ;r, t_'^, a V r n, i cr , ... ., >.,-....<�_--._..,a -.._ _ _ .:.�_ _n'n'•�-rr-�r-.ter-f-e._--�--tea-n L I I c ;; R �_;- ��' '�', r;' ,. � ; �. , ; ,,` , F- �;' (' , �� -_ _� _ ..... _ _ - -.. ..__._ - .� -_ ..� - - ___ _.. _��,._. ,.__ ....._._ n-. r . _., �_ _._._ .-_ . _ _ .,_,_ �_ _ � __� � ._._- _ __ -- __ __--- - ___ - _� --- �� - - _- . _ a_w_ �.,�.� � _ - _ _ _ --- --- _. �� _ _.__... - w.va�n. _�_.--- � ____ _..�..____..._ --. __.____.--- _ _ - ___ __ ---- ,. .. __ -_ _�_ �,. ,r. MOTION 5EN50R BYPASS SWITCH. ARROW -HART "1991L. SINGLE POLE, LOCK TYPE, MOUNT ON ADJACENT WALL &'-0' AFF, NEAR POWER PACK. THE WATT STOPPER INC. POWER PACK • A -120-E LIGHTING CIRCUIT NOTE: MAKE CONNECTIONS BETWEEN POWER PACK AND MOTION 5EN50R OR 5EN5OR5 PER THE MANUFACTURERS RECCOMENDATION. I I ADDITIONAL 5EN50R5 CONTROLLING THE SAME FIXTURES AS INDICATED ON THE PLANS MAXIMUM 3 PER POWER PACK. r LIGHTING LOAD MOTION SENSORS. THE WATT STOPPER, INC (LR) MODEL CI -100-I PASSIVE I.R. (TW) MODEL CI -100-H PASSIVE I.R. WITH BR -I 4 CM -100 MOUNTING BRACKETS (EXCEPT US). AIM IN DIRECTION INDICATED ON PLANS. MOTION DETECTOR DIAGRAM AHU'S 1, 2 & 3 SHALL SHUT DOWN UPON ALARM CONDITION. AHU'S 1, 2 & 3 DUCT DETECTORS BUILDING ANNUNCIATION STORAGE AREA DETECTION STORAGE AREA DETECTION OFFICE AREA DETECTION REMOTE ANNUNCIATOR FIRE IN OFFICE LOBBY ALARM PANEL REMOTE ANNUNCIATOR IN APARTMENT REMOTE COMMUNICATOR AT TELEPHONE BACKBOARD (2-- OUTSIDE LINES FOR REMOTE MONITORING) F, i iii - N-4- MON 111111i�,_; { WP NOTE: STROBE ANNUNCIATORS SHALL BE 75 CANDELA MINIMUM. NOTE: ALL FIRE ALARM WIRING SHALL BE IN CONDUIT. FOLLOW MANUFACTURER'S RECOMENDATION FOR WIRE TYPE AND SIZE INCLUDING ANY ALLOWANCE FOR VOLTAGE DROP. TYPICAL AHU TYPICAL CU PANEL A 400A MLG 2401170V I -P. 9-W 42 SPACE T -I !-A EXTERIOR LIGHTING P.C. & TIMER GENERAL LIGHTING GENERAL POWER 3/4' C. W/ 1-2/0 G. I3/4' x I DRI GRGR ,rI DRIVEN OUND ROD 2 - 2-I/2' C. W/ 2 - 250 KCM, 1 - 4/0 N., I - 0-3 G. PER EACH, AI GENERAL REV15ION PANELBOARD DESIGNATION: A LIGHTING FIXTURE SCHEDULE MRK DESCRIPTION MANUFACTURER CATALOG NUMBER LAMPS REMARKS A 8' STRIP, 2 -LAMP LITHONIA C -296 -120 -ES 2-F96 75W RS/ES/CW BUILDING EXTERIOR B 4' STRIP, 2 -LAMP LITHONIA C -240 -120 -ES 2-F40 34W RS/ES/CW ON WALL D SURFACE WRAPAROUND LITHONIA WA -240 -120 -ES 2-F40 34W RS/ES/CW ON WALL F FL. DOWNLI GHT LITHONIA AF2-221 3TT-6AR-HPF 2-1 3W PL TT 4100K ON WALL H 2 X 4 TROFFER, 2 -LAMP LITHONIA 2GT-240-FWA12-120-ES 2-F40 34W RS/ES/CW ON WALL J 2 X 4 TROFFER, 4 -LAMP LITHONIA 2GT-440-FWA12-120-ES 4-F40 34W RS/ES/CW NEAR UNIT K M. H. WALLPACK LITHONIA TWH-1 75M-1 20 -MT 1 -1 75W M. H. 45A 04 FL, UNDER CABINET, 4' LITHONIA 2UC-1 40 -AR -1 20ES 1 -F40 34W RS/ES/CW 50A U SURFACE CEILING LITHONIA VR3C-75M-120TB 1-70W M. H. 60A V PARKING LOT LITHONIA KSF2-400M-I 11 -208 1 -40OW M. H. TYPE 3 DI STR. 2 POLE FOR 'V* FIXTURE FIBERGLASS DIRECT BURIAL POLE, 25 FT ABOVE GRADE, DARK B Z, TENON ARM Y M. H. WALLPACK LITHONIA TWH-1 OOM-208-MT 1 --1 OOW M. H. 90A 2 2-#3, 1-#8 G. 1 1/4- 10 2W 100A 2 2-#3. 1-#8 G. 1 1/4- 1 10 2W LTG - STORAGE LTG - STORAGE 20 1500 15 2865 NOTES: 1. ALL CONDUCTORS SHALL BE COPPER. 2. ALL CONDUIT SHALL HAVE GROUNDING CONDUCTOR INSTALLED. 3. CONDUIT BELOW GRADE OUTSIDE OF BUILDING SHALL BE 1" MINIMUM. 4. SIZING OF CONDUCTORS MUST BE ALTERED FOR DERATING PER N.E.C. OR VOLTAGE DROP CONSIDERATIONS. 1 5. SEE RISER DIAGRAM FOR SIZING OF CIRCUITS GREATER THAN 100A. 6. VERIFY IF NEUTRAL IS REQUIRED FOR ANY EQUIPMENT. X1 EXIT SIGN, SINGLE FACE LI THOM A LOM -SWI -R -120 -EL L. E. D. BATTERY BKUP. X2 EXIT SIGN, DOUBLE FACE LITHONIA LOM-SW2-R-1 20 -EL L. E. D. BATTERY BKUP. EL EMERGENCY EGRESS 7717TfTiTONI A isELM2 2- 6V 7. 2W BATTERY BKUP. 20 SPACE SPACE WP NOTE: STROBE ANNUNCIATORS SHALL BE 75 CANDELA MINIMUM. NOTE: ALL FIRE ALARM WIRING SHALL BE IN CONDUIT. FOLLOW MANUFACTURER'S RECOMENDATION FOR WIRE TYPE AND SIZE INCLUDING ANY ALLOWANCE FOR VOLTAGE DROP. TYPICAL AHU TYPICAL CU PANEL A 400A MLG 2401170V I -P. 9-W 42 SPACE T -I !-A EXTERIOR LIGHTING P.C. & TIMER GENERAL LIGHTING GENERAL POWER 3/4' C. W/ 1-2/0 G. I3/4' x I DRI GRGR ,rI DRIVEN OUND ROD 2 - 2-I/2' C. W/ 2 - 250 KCM, 1 - 4/0 N., I - 0-3 G. PER EACH, AI GENERAL REV15ION PANELBOARD DESIGNATION: A DISCONNECT SCHEDULE D. S. # SI ZE PULES PHASE NEMA FUSE NON F UNI T SERVED LOCATION 1 2-#12, 1-#12 G. 400A 2 1 3R 400A SERVICE ENTRANCE BUILDING EXTERIOR 2 2-#12, 1-#12 G_ 60A 2 1 3R 60A CU -11 CU -2, CU -3 ON WALL 3 2-#10, 1-#10 G. 30A 2 1 3R 20A CU -4 ON WALL 4 2-#10, 1-#10 G. 30A 2 1 1 25A AHU-4 (W/ 5 KW HEAT) ON WALL 5 2-#10, 1-#10 G. 60A 2 1 1 3R 35A CU -5 ON WALL 6 2-#10, 1-#10 G. 30A 2 1 1_1 30A 1 AHU-5 (W/ 5 KW HEAT) NEAR UNIT 2 2-#8, 1-#10 G. 1" IV 2W 45A 2 DISCONNECT NOTES, I . EXHAUST FANS SHALL HAVE A PDA, SINGLE POLE SWITCH DISCONNECT. 2. OTHER SINGLE POLE, 20A DEVICES REQUIRING DISCONNECTS SHALT, HAVE A 20A, SINGLE POLE SWITCH AS A DISCONNECT. 3. FUSES SHALL BE DUAL ELEMENT TIME DELAY. 4. VERIFY FUSE SIZES REQUIRED FOR ACTUAL EQUIPMENT SUBMITTED. 5. AHU'S 1, 2 AND 3 SHALL HAVE A 2 -POLE MOTOR DUTY RATED SWITCH, WP NOTE: STROBE ANNUNCIATORS SHALL BE 75 CANDELA MINIMUM. NOTE: ALL FIRE ALARM WIRING SHALL BE IN CONDUIT. FOLLOW MANUFACTURER'S RECOMENDATION FOR WIRE TYPE AND SIZE INCLUDING ANY ALLOWANCE FOR VOLTAGE DROP. TYPICAL AHU TYPICAL CU PANEL A 400A MLG 2401170V I -P. 9-W 42 SPACE T -I !-A EXTERIOR LIGHTING P.C. & TIMER GENERAL LIGHTING GENERAL POWER 3/4' C. W/ 1-2/0 G. I3/4' x I DRI GRGR ,rI DRIVEN OUND ROD 2 - 2-I/2' C. W/ 2 - 250 KCM, 1 - 4/0 N., I - 0-3 G. PER EACH, AI GENERAL REV15ION PANELBOARD DESIGNATION: A CONDUIT AND WIRE SCHEDULE C/B POLE WIRE SIZE (BASED UPON TYPE THW) CONDUIT PHASE 20A 1 2-#12, 1-#12 G. 3/4" 10 2W 20A 2 2-#12, 1-#12 G_ 3/4' 10 2W 25A 1 2-#10, 1-#10 G. 3/4" 10 2W 25A 2 2-#10, 1-#10 G. 3/4" 10 2W 30A 1 2-#10, 1-#10 G. 3/4" 10 2W 30A 2 2-#10, 1-#10 G. 3/4" 10 2W 40A 2 2-#8, 1-#10 G. 1" IV 2W 45A 2 2-#8. 1-#10 G_ t" 191 2W 50A 2 2-#8, 1-#10 G. 1" 10 2W 60A 2 2-#6, 1-#10 G. 1" 10 2W 70A 2 2-#4. 1--#8 G. 1" 10 2W 80A 2 2-#4, 1-#8 G. 1" 10 2W 90A 2 2-#3, 1-#8 G. 1 1/4- 10 2W 100A 2 2-#3. 1-#8 G. 1 1/4- 1 10 2W LTG - STORAGE LTG - STORAGE 20 1500 15 2865 NOTES: 1. ALL CONDUCTORS SHALL BE COPPER. 2. ALL CONDUIT SHALL HAVE GROUNDING CONDUCTOR INSTALLED. 3. CONDUIT BELOW GRADE OUTSIDE OF BUILDING SHALL BE 1" MINIMUM. 4. SIZING OF CONDUCTORS MUST BE ALTERED FOR DERATING PER N.E.C. OR VOLTAGE DROP CONSIDERATIONS. 1 5. SEE RISER DIAGRAM FOR SIZING OF CIRCUITS GREATER THAN 100A. 6. VERIFY IF NEUTRAL IS REQUIRED FOR ANY EQUIPMENT. 1365 WP NOTE: STROBE ANNUNCIATORS SHALL BE 75 CANDELA MINIMUM. NOTE: ALL FIRE ALARM WIRING SHALL BE IN CONDUIT. FOLLOW MANUFACTURER'S RECOMENDATION FOR WIRE TYPE AND SIZE INCLUDING ANY ALLOWANCE FOR VOLTAGE DROP. TYPICAL AHU TYPICAL CU PANEL A 400A MLG 2401170V I -P. 9-W 42 SPACE T -I !-A EXTERIOR LIGHTING P.C. & TIMER GENERAL LIGHTING GENERAL POWER 3/4' C. W/ 1-2/0 G. I3/4' x I DRI GRGR ,rI DRIVEN OUND ROD 2 - 2-I/2' C. W/ 2 - 250 KCM, 1 - 4/0 N., I - 0-3 G. PER EACH, AI GENERAL REV15ION PANELBOARD DESIGNATION: A ' 04 VOLTAGE: 240/120V 1P/3VV MAINS RATING: 40FTA ENCLOSURE: NEMA 1 SURFACE ❑ ❑ FLUSH IM MCB MLO COPPER BUS MAIN CB TRIP RATING: 400 A INTERRUPTING RATING: 22,000 AIC SERVES Ca SIZE LOAD CKT (VA) # PHASE LOADS(VA) A B CKT # LOAD (VA) CO SIZE SERVES RECEPS - STORAGE 20 1440 1 2160 2 720 20 RECEPS -OFFICE RECEPS - STORAGE 20 1440 3 2160 4 720 20 RECEPS - OFFICE TELEPHONE BACKBOARD 20 360 5 1080 8 720 20 RECEPS - OFFICE FIRE ALARM PANEL 20 500 7 1220 8 720 20 RECEPS - OFFICE WATER HEATER 25 2000 9 2540 10 540 20 RECEPS - BREAK COUNTER SPACE 11 ru ri r� ai ai 1560 12 1560 20 LTG - BLDG EXTERIOR LTG - STORAGE 20 1690 13 3185 14 1495 2U LTG - STORAGE LTG - STORAGE 20 1500 15 2865 18 1365 20 LTG - STORAGE LTG - OFFICE 20 780 17 1625 18 845 20 LTG - STORAGE LTG - OFFICE 20 1400 19 1400 20 SPACE SPACE 21 0 22 SPACE SPACE 23 3720 24 3720 60 CU -3 SPACE 25 3720 28 3720 AHU-4 W 5 KW HEAT 25 2848 27 3636 28 790 20 AHU-1 2848 29 3638 30 790 CU -4 20 900 31 4620 32 3720 60 CU -1 900 33 4620 34 3720 AHU-2, AHU-3 20 1580 35 4666 38 0 37 4668 38 CU -2 60 —5a 3720 39 5940 40 37201 41 5940 42 CONNECTED— 65 KVA * LOCK IN ON POSITION TOTALS 33.1761 31,791 ESTIMATED DEMAND— 61 KVA 400 A MAIN DISCONNECT METER JCOORDINATE EXACT METERING O METHOD AND REQUIREMENTS WITH POWER CO. 2 - 2 -1/2' C. W/ 2 - 250 KCM, 1 - 4/0 N. PER EACH. TO POWER CO. SERVICE POINT (HANDHOLE OR PADMOUNT TRANSFORMER, COORDINATE W/ POUTER CO.) ELECTRICAL RISER 1. SCOPE The scope of the work covered herein consists of furnishing all labor, materials, necessary equipment and services to complete the Electrical Work and related work in full ac- cordance as indicated on the drawings, as specified herein or both and subject to the terms and conditions of the Contract. All items noted herein, shown by the electrical plons, or reasonably to be interpreted from the plans necessary to complete the electricol system shall be provided and installed under the work of this Section.- whether some ore specifically mentioned herein or not. 2. CODES, RULES. PERMITS, FEES Electrical Contractor is generally responsible to insure all work, both old and new, complies with the NEC and any applicable local and state codes and ordinances. 3. DRAWINGS Drawings are diagrammatic and indicate the general arrangement of systems and work included in the contract. Drawings ore not to be scoled. The Architectural drawings and details shall be examined for exact location of fixtures and equipment. Any conflict shall be immediately brought to the attention of the Architect or Engineer before proceeding with the work. 4. SHOP DRAWINGS The Subcontractor sholl submit six (6) copies for approval of detailed shop drawings of all equipment and all material required to complete the project to the Engineer. Materials or products specified herein and/or indicated on drawings by trade name, manufacturer's name or catalog number shall be provided as specified. 5. COOPERATION WITH OTHER TRADES The Subcontractor shall give full cooperation to other trades and shall furnish in writing to the Contractor, with copies to the Engineer, any information necessary to permit the work of all trades to be installed satisfactorily and with the least possible interference or delay. Coordinate all conduit runs and equipment with other trades. Verify nameplate electrical data of actual equipment furnished by others before beginning inslallotion. 6. CUTTING, PATCHING, AND FINISHING The Electrical Contractor shall do all cutting, drilling, etc, required for work under this section of the specifications, inside and outside the building, including preparing of finished surfaces, oil required shoring and bracing, and all protection for safely of persons and property. 7. EXCAVATING AND BACKFILLING The Subcontractor shall do all trench and pit excavating and backfilling required for work under this section of the specifications, inside and outside the building, including repairing of finished surfaces, all required shoring, bracing, pumping, and all protection for safety of persons and properly. 8. MATERIAL AND WORKMANSHIP All materials and apparatus required for the work shall be new unless indicated otherwise on the plans. Electrical contractor shall provide and install all electrical as shown, verifying all mounting tleights and exact locations of oil wall -mounted electrical devices with architect prior to rough -in. Connections and junction boxes to equipment are diagrammatic. Verify exact location of connection to specific equipment and devices. 9. PANELBOARDS Ponels shall be as manufactured by Square 0, G.E., ITE or equivalent of sizes, ratings, and requirements shown on the plans. Panels shall be of dead front construction . All bussing shall be copper. Minimum width of panels shall be 14". New circuit breakers shall be 20A minimum. Multi -pole breakers shall have a single handle to trip all poles at once. AIC rating of breakers shall match AIC rating of panel. A laminated block plastic with white lettering plastic nameplate with the identification number as shown on the panel schedule shall be mounted on the outside of the door with sheet metal screws. Nameplate size shall be 3" wide x 1-1/2" high with 1/2' high engraving. Provide a completed circuit directory, typed and mounted in a clear plastic sleave, on the interior of the panel door. AIC of breaker shall match panel rating where installed. 10. GROUNDING Provide a complete grounding network for the entire electrical system to comply with NEC requirements. All conduits shall hove a ground wire installed. A conduit ground shall not be used. Bond service entrance ground to building steel, metal water mains, made electrodes, etc. 11. DISCONNECT SWITCHES Equipment disconnect switches shall be Square D. C.E., ITE or equivalent general duty of the type and ratings shown on the plans. Fuses shall be provided of the appropriate type and rating for the equipment to be served. 12. MISCELLANEOUS EOUIPMENT o. Switches - All general use lighting (SPST toggle with or without pilot) switches to be rated 20A., 120-277V. as manufactured by Leviton, Lutron. P & S. or equivalent. Coordinate color with Owner/Architect. b. Receptacles — All general use duplex receptacles to be rated 20A., 120V as manufactured by Leviton, Lutron, P & S. or equivalent. Coordinate color with Owner/Architect. C. Power/lighting circuits - All power/lighting circuits 100A or less sholl be as indicated on the wire and conduit schedule. Other circuits shall be as shown on the plans. d. Homeruns — All homeruns shall be o minimum of 3/4" conduit w/maximum 40% fill. e. Conductors -- All conductors shall be rated 600V, copper. type THW, THWN, XHHW/THHN. Wire/conduit sizing/fill is based upon type THW conductors. conductors of #8 AWO and larger shall be stranded. f. Timers - A Tork #T920L shall be used for lighting control. Multiple units may be required for oil controlled circuits shown on the plans. g. Photo Control - A Tork #2100 shall be mounted where shown on the drawings. h. Lighting fixtures - Lighting fixtures shall be as indicated on the Fixture schedule or approved equals. 13. CONDUIT Conduit shall be EMT, CRC, SCH. 40 PVC, liquid tight metal flexible, or metol flexible, CRC shall be used at exposed exterior locations. Liquid tight flex shall be used for connection to all fixed equipment except lighting fixtures where o 6' maximum length of flexible may be used. EMT shall be used of oil exposed interior locations. All remaining locations may use PVC, Insulating bushings with double lock -nuts shall be used for entrance of 1-1/4" C. or larger into enclosures. Sizes indicated are minimums, larger sizes may be used to facilitate wire pulls, etc. 14. EQUIPMENT FURNISHED BY OTHERS Electrical Contractor shall provide all conduit, wire and disconnect switches to connect electrical equipment supplied by others which shall include both new and relocation of existing equipment. All final electrical connections are to be by electrical contractor. 15, RECORD DRAWINGS The Contractor shall keep accurate records of actual con- struction including device locations and conduit runs if different from the plans. The Contractor shall provide the owner with a reproducible set of plans of the complete electrical and fire alarm systems as installed (as built drawings). The scale on these as built drawings shall be no smaller than the scale used on the original plans. 16. TESTING Final tests shall be made only after the Engineer is satisfied that all work has been completed. 17. FINAL ACCEPTANCE After testing a final inspection shall be made by the Engineer and other authorized persons with the Electrical Contractor. Final acceptance of the project shall not prejudice the Owner's right to require replacement and/or repair of any defective work or materials. ELECTRICAL 5FECIFICATION5 PIN 41651 E3 20 OF 25 04 4A c� W� o U A �v cc LU 0'0 Q LU V W =' 0 W 4 cc z LL- o o V) Z ,o 0� W� - l5 [Y ' ru ri r� ai ai 10. GROUNDING Provide a complete grounding network for the entire electrical system to comply with NEC requirements. All conduits shall hove a ground wire installed. A conduit ground shall not be used. Bond service entrance ground to building steel, metal water mains, made electrodes, etc. 11. DISCONNECT SWITCHES Equipment disconnect switches shall be Square D. C.E., ITE or equivalent general duty of the type and ratings shown on the plans. Fuses shall be provided of the appropriate type and rating for the equipment to be served. 12. MISCELLANEOUS EOUIPMENT o. Switches - All general use lighting (SPST toggle with or without pilot) switches to be rated 20A., 120-277V. as manufactured by Leviton, Lutron. P & S. or equivalent. Coordinate color with Owner/Architect. b. Receptacles — All general use duplex receptacles to be rated 20A., 120V as manufactured by Leviton, Lutron, P & S. or equivalent. Coordinate color with Owner/Architect. C. Power/lighting circuits - All power/lighting circuits 100A or less sholl be as indicated on the wire and conduit schedule. Other circuits shall be as shown on the plans. d. Homeruns — All homeruns shall be o minimum of 3/4" conduit w/maximum 40% fill. e. Conductors -- All conductors shall be rated 600V, copper. type THW, THWN, XHHW/THHN. Wire/conduit sizing/fill is based upon type THW conductors. conductors of #8 AWO and larger shall be stranded. f. Timers - A Tork #T920L shall be used for lighting control. Multiple units may be required for oil controlled circuits shown on the plans. g. Photo Control - A Tork #2100 shall be mounted where shown on the drawings. h. Lighting fixtures - Lighting fixtures shall be as indicated on the Fixture schedule or approved equals. 13. CONDUIT Conduit shall be EMT, CRC, SCH. 40 PVC, liquid tight metal flexible, or metol flexible, CRC shall be used at exposed exterior locations. Liquid tight flex shall be used for connection to all fixed equipment except lighting fixtures where o 6' maximum length of flexible may be used. EMT shall be used of oil exposed interior locations. All remaining locations may use PVC, Insulating bushings with double lock -nuts shall be used for entrance of 1-1/4" C. or larger into enclosures. Sizes indicated are minimums, larger sizes may be used to facilitate wire pulls, etc. 14. EQUIPMENT FURNISHED BY OTHERS Electrical Contractor shall provide all conduit, wire and disconnect switches to connect electrical equipment supplied by others which shall include both new and relocation of existing equipment. All final electrical connections are to be by electrical contractor. 15, RECORD DRAWINGS The Contractor shall keep accurate records of actual con- struction including device locations and conduit runs if different from the plans. The Contractor shall provide the owner with a reproducible set of plans of the complete electrical and fire alarm systems as installed (as built drawings). The scale on these as built drawings shall be no smaller than the scale used on the original plans. 16. TESTING Final tests shall be made only after the Engineer is satisfied that all work has been completed. 17. FINAL ACCEPTANCE After testing a final inspection shall be made by the Engineer and other authorized persons with the Electrical Contractor. Final acceptance of the project shall not prejudice the Owner's right to require replacement and/or repair of any defective work or materials. ELECTRICAL 5FECIFICATION5 PIN 41651 E3 20 OF 25