405 Central Park Dr - #91-001816 (HALLMARK HEALTH CARE) DOCUMENTSFLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION rf RM 500-A-91 SECTION 5 ® BUILDING DESIGNBY COMPONENT PERFORMANCE APPROACH ADMINISTERED BY THE DEPARTMENT OF COMMUNITY AFFAIRS Non-ResidentialBuildings Residential Buildings over 3 stories ALL CLIMATE ZONES PROJECT NAME: mak, Health Care ZONE: ADDRESS: 40 Central Park Dr. BUILDING CLASSIFICATIONS : Office Warehouse 640 CITY ZIP CODE: Sanford FL. BUILDING PERMIT NO.: SF l BUILDER: Contem` orary Builders _ PERMITTING OFFICE:-00 t S. OWNER:' JURISDICTION NO.: BUILDING INFORMATION i WALLS ROOFICEILING FLOORS DOOR GLASS TYPE U AREA TYPE U AREA TYPE U AREA TYPE U' AREA TYPE U AREA Concrete (CBS) . amp Under attic • Slab -on -grade " Wood ' Metal Single, wall. Double; wall Wood frame Single Assembly Raised Wood Insul Single, roof Metal frame Other: Raised concrete Other s3 Double; roof i insulation R-value Insulation R-value Insulation R-value l SYSTEMS INFORMATION AIR CONDITIONER HEATING :YS'TEM ems® HOT WATER i CFF! C,e'.OY 11IIH TvDE.-- TYPE EFFICIENCY TONS TYPE Unitary 8 Heat Pump. Central & Heat Pump Electric ZTOA < 65, 000 BtuIh" HSPF 5 Resistance none 65,o00Btu it, .SEER 65,000 Btu Ih COP; Dedicated Heat Pump ' 65,000 Bruih EER IPLV' Water' cooled COP Gas Water Co ed EER IPLV Natural ql EvaporativelycooledCOPEvaperativelycooled EER Electric resistance:, COP LPG El PTAC ' EER Gas/Oil (circle one), Oil El Chillers COP IPLV < 225,0001300, 000 Bluth. , ' AFUE HRIJ 225,000/ 300,000 Btu/h E1 Other. Other Lighting Budget ( from Table 5-.1 LIGHTING TotalLighting Wattage 1750 - Total Conditioned Floor Area 640 = Watts/sq. it: • -- PRESCRIPTIVE MEASURE ( Murst be mot or exceeded by all buildings.) NTS" SECTION REQUIREMENTS CHECK 502.4 Maximum of _37 cfm per linear foot of operable sash crack. _ X rD.= 5502.4Maximum of 1.25 cfm'per square foot of door area; X- 502.4 To be caulked, gasketed, weatherstripped or otherwise sealed. Supply air restricted to set cold/hot deck temperature to meet load of worst case zone. Resistance reheat prohibited.503.4 503.3 Supplied with readily accessible switch for shut off and/or volume ieduction when ventilation is not required. Xncy 503.4" 503:5 Minimum efficiencies - Heating: Tables 5-4, 5-5 & 5-6. Cooling: Tables 5-7A, 5-7B,'5-8 & 5-9. Minimum'of 8.0. Transport.EnergyBalancing503. 6 Provide means for balancing HVAC air system & water distributions stem. x HVAC Controls 503.7 Separate readily accessible manual or automatic. thermostat for each system. HVAC Ducts 503.8 Air ducts, fittings, mechanical equipment and plenum chambers shall be mechanically attached, sealed, 503.9 insulated and installed in accordance with the criteria of sections 503.8, 503.9.and 503.10. X 503.10 Piping Insulation 503.11 504.2 In accordance with Table 5-10. Automatic electric storage water heaters 5120 gallons and gas & oil -fired storage water heaters Larger sizedwaterheatersshallXWater Heaterss75, 000 Btu/h shall meet performance minimums in Table 5-11. meet minimums in Table 11-1 of Standard II after 1/1/92. Swimming Pools 504.2 Spas & heated pools must have covers. Non-commercial pools must have pump timer. . Spas 504. 4 Gas spa & pool heaters must have minimum thermal efficiency of 78%. Piping heat' loss is limited to 17.5 Btu/h linear foot of pipe for recirculating systems (see Table 5 12). Hot WaterPipe" Insulation 504. 5 Water flow restricted to maximum,of 3 gpm at 80 psig; toilets maximum 3.5 gallon flush., X Water Fixtures Public lavatory fixture maximum flow of .5 gpm or .5 gallon if has self=closing valve. 505A Lighting power budgets are listed in Table 5-13. Minimum Ballast Efficacy Factors are listed in Table 5-14. X Lighting i Uo wall Allowable Uo wall Actual r It complying under the provisions of S. 5021, enter the combined Uo values for the entire envelope Uo roof ( ceiling Allowa le Uo roof Icellmg Acur. I aJ .( -- in this section. U envelope Allowable Uo envelope Actual i Uo floor Allowable Uo floorActua. ,.c =- o OTTV wall Allowable OTTV wall Actual OTTV roof/ ceiling Allowa le : t _-- _ OTTV roof/ceiling Actual Compliance with Section 5 was demor tra' ed aPres(•,ipti've Measures methodology: I 508. 0 (a) Detached commer la A)utld nos . 508.0 (b)-Skyboxes or spprt, stadium buildings less than 100 square feet that are used only seasonally. I I Ihereby certify that the plans and specifications coverad by the calculation are in compliance Review of plans and specfrcations covered by, this calculation indicates compliance with the with the Florida Energy e: Florida Energy Code Before c nstru.:uan is completed his building -will b i for PRIPARED BY herd SteV@ DATE=r%-l compliance m accordan wi- 'on 53.908,FtS.. 1 lA/ - hereby certify that th r co I' r' a nergy a BUILDIN(( 6 f FI/L- - -- ---- DATE _-_ DATE - L_.. .. OWNER/ AGENT: Interior air film R TOTAL l , 77. L 1 . U = 1/R ROOFICEILING R•VALUES BUILDING CIOMPONENT DESCRIPTION ROOF TYPE 1 ROOF TYPE 2. ROOF TYPE 3 ROOF TYPE 4 ROOF . TYPE 5 Room air film Wall board Truss Insulation la 04, q, Other ikLG 'fiL.!t Other Other Other Outside air film r t R TOTAL U=1/R AREA (sq. ft.) U_TC '; E IF FRAME: Size is Inches O.C: HEATING DESIGN Uo -7- WALLS Wall Surface Winter Totals Type Area, ft2 U-Value Total all Door Surface Winter Type Area, ft2 U-ValU9 Total Glizinq Surface Winter ype pe tall 7. Heating 8. line 1+3+5 line 2+4+6 owi 214 From Table 5-2: Uow Allowed COOLING DESIGN OTTV WALLS' Wall Surface Summer TDeq Totals Type Area, ft2 U-Value (See Table Type 1 44 Type 2, Total Door Surface Summer TDeq Total r Glazing Orient. Surface OSFL Shading Total Z line 14 OTTVOW From Table 5-2: OTTVow Allowed HEATING DESIGN Uo — ROOF Poof Surface Winter Totals Vpe Area, ft2 U•Value Type 40.9 x Type 2 x Type 3 x Type 4 x Total AopagUe Total 20. 3 1 .- roof 19. Skylight Surface Winter . Type Area, ft2 U•Value Type 1 x Type 2 x Type 3 x Total Askylight 21. Total 22. Total Aor 23. ft2 Total Heating 24. 3 1 "4 line 19. + 21 line 20 + 22 31" ` f f D 25. o. D `f I Uor = line 24 line 23 Uor Actual From Table 5-2: Uor Allowed HEATING DESIGN Uo — FLOOR Floor Surface Winter Totals Type Area, ft= U•Value Type X = Type 2 x = Type, 3 x = Type 4 Total Afloor x = 33• 640 ft2 Total Heating 34. Uof := 35. line 34 line 33 Uof Actual From Table 5-2. Uof Allowed COOLING DESIGN OTTV — ROOF (If skylights used) Roof Surface Summer TDegr Totals Type Area, ft2 P U-Value (See Fig. 5.1) 3 Type 1 64 x o f_ x Type 2 x x = Type 3 x x Type 4 x x = Total AopagUe 3 3roof26. Total 27. Skylight Surface Shading Type Area, ft2 Coefficient - Type 1 x 138 x ) .= Type 2 x 138 x ) _ Type 3 x 138 x ) _ Total 3 .... Askylight 28. Total29A. Summer U `/alue A T x ( x ) = Total 29B. line 28 3 Total Aor 30 Total Cooling 31. line 26 + 28 215 9 3 27 t0 = 32. 29A + 29B 3 ,1 OTTVor = line 31 line 30 OTTVor Actual From Table 5-2: 2 OTTVor Allowed HEATING DESIGN Up AVERAGING' (Sec. 502.20)) U Envelope Allowable (take U values from Table 5-2): x ) + ( X ) + ( X ) Uow Aow (line 7) Uor Aor (line 23) Uof Aof (line 33) AE (line 7 + line 23 + line 33) UE AllowedUEnvelopeActual (use actual calculated U values): x )+( x )+(—x ) Wow (line 9) Aaw (line 7) U'or (line 25) Aor (line 23) U'of (line 35) Aof (line 33) AE (line 7 + line 23 + line 33) = UE Actual Cooling OTTVs may not be averaged.