Loading...
1081 WP Ball Blvd - BC05-001001 (ALTERNATIVE CLINIC) (INTERIOR REMODEL) (A)PERMIT ADDRESS W \ SUBDIVISION CONTRACTOR PERMIT # CG DATE `— --d Young Contracting Co. Inc. - ADDRESS 8215 Roswell Rd. Bldg 400 PERMIT DESCRIPTION —'Q-,�' � Atlanta, GA 30350 - CGC053552 PERMIT VALUATION 770-522-9270 FAX 770-522-9273 PHONE NUMBER SQUARE FOOTAGE PROPERTY OWNS North American Properties LLC ADDRESS 1080 Holcomb Bridge Bldg 200 Ste. 150 _ Roswell, GA 30076 770-325-4912 — PHONE NUMBER ELECTRICAL CONTRACTOR MECHANICAL CONTRACTOR PLUMBING CONTRACTOR MISCELLANEOUS CONTRACTOR PERMIT NUMBER . FEE MISCELLANEOUS CONTRACTOR PERMIT NUMBER FEE re G SA.NFIORD .FIRE DF_P.,IRTN1FNT FIRE PREVENTION DIVISION 300 N. Park Ave., Sanford, Fl. 32771 / P. O. Box 1788, Sanford, FI. 32772 (407302-2520 / TAX (407) 330-5677 Pager (407) 918-0395 Plans Review Sheet Date: November 16, 2004 Business Address: 1081 W.P. Ball Blvd. Occ. Ch. 36 New Mercantile Business Name: New Interior White Box (c�,)1081W.P. Ball Blvd. Contractor: Young Contracting Company Ph. (770) 522-9270 FAX. (770) 522-9273 Comment: Plans reviewed as Mercantile Occupancy Class "C". FD reserves right to require applicable code requirements if occupancy use changes. Application — New Building. 1,508 sq. ft. New Mercantile occupancy Mixed — N/A 1.1 Special Definitions — N/N 1.2 Classification of Occupancy — Class "C" (LESS THAN 3,000 sq. ft.) 1.3 Classification of Hazard of Contents — Ordinary per 6.2.2.2. F.F.P.C. 1.4 Minimum Construction — N/R (NO SPECIAL REQUIRMENTS) 2.2 Means of Egress Components 2.3 Capacity of Egress O I` 33�E 2.4 Number of Exits — Two (2) Front and rear 2.5 Arrangement of Egress — O.K., will field verify, per section 7.5>FFP. C. 2.6 Travel Distance — Shall not exceed 75'36- 2.4. TEAM MEMBERS OWNER: NORTH AMERICAN PROPERTIES JEFF PAPE OCCUPANT 1080 HOLCOMB BRIDGE ROAD JOEL MABRY FLORIDA BUILDING CODE (FBC) BLDG. 200 SUITE 150 TEL: (770) 643-6566 1,508 ROSWELL, GA 30075 FAX: (770) 643-9540 ARCHITECT: PHILLIPS PARTNERSHIP ROB FRENCH 2002 9000 CENTRAL PARK WEST DWIGHT BAILEY FLORIDA BUILDING CODE - GAS VOLUME (IGV) SUITE 400 TEL: (770) 394-1616 ATLANTA, GA 30328 FAX: (770) 394-1314 CIVIL: KIMLEY-HORN ASSOCIATES JEFF BRITTAIN MECHANICAL VOLUME (IMV) 3660 MAGUIRE BLVD. EDITION SUITE 200 TEL: (407) 898-1511 ORLANDO, FL 32803 FAX: (407) 898-4791 STRUCTURAL: HAINES GIPSON & ASSOCIATES RANDY GIPSON 1550 NORTH BROWN ROAD SUITE 100 TEL: (770) 491-7550 TUCKER, GA 30043 FAX: (770) 491-7750 MECHANICAL/ JORDAN & SKALA LYNN WITCHER PLUMBING: 5365 OAKBROOK PARKWAY JEREMY WAITS NORCROSS, GA 30093 TEL: (770) 447-5547 FAX: (770) 448-0262 ELECTRICAL: JORDAN & SKALA TONY OWEN 5365 OAKBROOK PARKWAY TEL: (770) 447-5547 NORCROSS, GA 30093 FAX: (770) 448-0262 LANDSCAPE SITE SOLUTIONS DAVID FLOYD ARCHITECT: 5064 ROSWELL ROAD MONIQUE LACASSE SUITE C-101 TEL: (404) 705-9411 ATLANTA, GA 30342 FAX: (404) 459-9412 GENERAL YOUNG CONTRACTING COMPANY RANDY THOMAS CONTRACTOR: 8215 ROSWELL ROAD TEL: (770) 522-9270 BUILDING 400 FAX: (770) 522-9273 ATLANTA, GA 30350 BUILDING CITY OF SANFORD DON FLORIAN DEPARTMENT: 300 N. PARK AVENUE SANFORD, FL 32772 TEL: (407) 330-5657 FIRE SANFORD FIRE DEPARTMENT TIM ROBLES DEPARTMENT: FIRE PREVENTION DIVISION P.O. BOX 1788 TEL: (407) 302-2520 SANFORD, FL 32771 FAX: (407) 302-2526 SITE THE BRIAR CORPORATION BOB HARRELL CONTRACTOR: PO BOX 470264 TEL: (407) 321-2773 LAKE MONROE, FL 32747 FAX 1081 W.P. BALL BOULEVARD THE MARKETPLACE AT SEMINOLE TOWNE CENTER SANFORD, FLORIDA A DEVELOPMENT FOR NORTH AMERICAN PROPERTIES 1080 HOLCOMB BRIDGE ROAD BUILDING 200, QUITE 150 ROSWELL, GEORGIA 30075 770-645-6566 PROJECT VICINITY SYMBOLS NIF�I)RMOMAPI LOCATION: CITY OF SANFORD 11.0 FACE OF STRUCTURE SEMINOLE COUNTY, FLORIDA valdez p� t} -- T ,tmi PROJECT ADDRESS: 'kms 11.5 CENTERLINE OF COLUMN saint Johns River Estates. , . 1081 W.P. BALL BOULEBARD Eool••,er To�v Si-trti6folza NOTE TAG REFERENCING aAstor Farms Fdr•k : ,t 24 SANFORD, FLORIDA 32771 .tlsGENERAL NOTES ON PLANS _ ;.. . , l i ght �I O B SITE La a Monroe CD DOOR NUMBER, U��1SSftoole Blvq 1c SEE DOOR SCHEDULE Alderene Park. i ay Sal Josephs 4� E 1st St �. srn laza ;,Nelson Corner P irk' l Sanford f 3% ELEVATION MARK { lab + A-4.1 New salami Markham Paola la 4 i F.3 enna-Park ?' s hte ori.3! a-Ro r:a ' +rk Paold VJ25thjSt1san ord a A-6.2 — — — F*ta fait Cemetery+ lavger Lake /Ala _ountrq Glut; ENLARGED PLAN Pi iecrest;s' DETAIL MARK Dawson Lake- .. �Greenbriar Park Lake marietta— ,. Lake 62004 A+IanC)uast.com. Inc.: t>2004 NAYTE(1 �_._. .. ! SITE ZONING; PD � SECTION MARK BUILDING SET BACKS: FRONT: 25'-0" A-5.4 'SIM' -SIMILAR REAR: 20'-0" 'OH'- OPPOSITE HAND SIDE: 10'-01, NORTH WIND SPEED: 110 MPH SIESMIC ZONE: REFER TO STRUCTURAL DRAWINGS SHOP A APPLICABLE CODES: OCCUPANT FLORIDA BUILDING CODE (FBC) 2001 EDITION 1,508 LIFE SAFETY CODE (NFPA 101) 2000 EDITION KEYPLAN NATIONAL ELECTRIC CODE (NEC) 2002 EDITION FLORIDA BUILDING CODE - GAS VOLUME (IGV) 2000 EDITION FLORIDA BUILDING CODE - MECHANICAL VOLUME (IMV) 2000 EDITION FLORIDA BUILDING CODE - PLUMBING VOLUME (IPV) 2000 EDITION OCCUPANCY CLASSIFICATION: TYPE OF CONSTRUCTION: ALLOWABLE HEIGHT: ACTUAL HEIGHT: ALLOWABLE AREA: OCCUPANT SEPARATION: TENANT SEPARATION: EXITS REQUIRED: EXITS PROVIDED: TRAVEL DISTANCE: MERCANTILE TYPE IV UNPROTECTED SPRINKLERED 2 STORIES - 55' ONE STORY - VARIES (35-0" MAX.) UNLIMITED (FBC 503.4.1) N/A 1 HOUR 1 HOUR 1 HOUR GENERAL NOTES 1 . GENERAL CONTRACTOR SHALL FIELD VERIFY SURVEY LOCATION AND ALL EXISTING CONDITIONS AND DIMENSIONS PRIOR TO CONSTRUCTION. ANY DISCREPANCIES SHALL BE REPORTED TO THE TENANT (IF APPLICABLE) AND ARCHITECT. 2. THE GENERAL CONTRACTOR SHALL OBTAIN PERMITS, APPROVALS, INSPECTIONS, CERTIFICATE FOR COMPLIANCE AND CERTIFICATE OF OCCUPANCY AS REQUIRED. 3. GENERAL CONTRACTOR SHALL CHECK IN WITH AND COORDINATE ALL WORK WITH THE LANDLORD'S PROJECT PERSONNEL. 4. GENERAL CONTRACTOR SHALL PROVIDE TEMPORARY POWER, LIGHT, AND TELEPHONE IN ACCORDANCE WITH THE LANDLORD'S REQUIREMENTS. GENERAL CONTRACTOR SHALL REMOVE ALL THESE ITEMS AT THE COMPLETION OF WORK OR AS REQUIRED. 5. GENERAL CONTRACTOR SHALL MAINTAIN ON SITE AT ALL TIMES, ALL APPROVED DRAWINGS INCLUDING ALL REVISIONS AND ADDENDA. 6. GENERAL CONTRACTOR SHALL COMPLETE ALL WORK IN A NEAT AND PROFESSIONAL MANNER. EGRESS CALCULATIONS USE AREA (S.F.) SQ. FT. PER OCCUPANT PERSON LOAD TOTAL OCCUPANCY 1,508 30 50 UNITS OF EGRESS REQUIRED (0.20" x 50) MEANS OF EGRESS AT FRONT (PROVIDED) MEANS OF EGRESS AT REAR (PROVIDED) TOTAL UNITS OF EGRESS (PROVIDED) 10 IN. (32 IN. MIN.) 68 INCHES NA INCHES 68 INCHES DRAWING INDEX ARCHITECTURAL A-0.1 A-1.1 MECHANICAL M-1.1 PLUMBING P-1.1 ELECTRICAL E-1.1 COVER SHEET FLOOR PLAN, DETAILS, & SPECS WHITE BOX FLOOR PLAN MECHANICAL WHITE BOX FLOOR PLAN PLUMBING WHITE BOX FLOOR PLAN ELECTRICAL By? _ t Sanford Fire -Pre e"t* Di Date: I e OCT 2 6 2004 REVISION # 38 SUMMARY A. SHEET ADDED PHILLIPS dw P A R T N E R S H I P Architecture - Interior Design - Planning P'— 770.394.1616 770.394.1314 RF RE �®TRJEFg* A A ANCHOR B CONSULTANT SEAL REVISIONS # DATE DESCRIPTION A 10/18/04 SHOPS WHITE BOX This document is ® Phillips Partnership. PC and is considered an Instrument of Service and is solely for use with respect to the project as indicated below. All rights reserved. This document may not he reproduced without the prior written consent of Phillips Partnership. PC. TENANT STANDARD WHITE BOX SHOP 1081 W.P. BALL BOULEVARD PROJECT THE MARKETPLACE AT SEMINOLE TOWNE CENTER 0 SANFORD, FLORIDA CLIENT 111111 NORTH AMERICAN PROPERTIES NORTH AMERICAN PROPERTIES - ATLANTA 1080 HOLCOMB BRIDGE ROAD BUILDING 200, SUITE 150 ROSWELL, GA 30075 TEL (770) 645-6566 FAX (770) 643-9540 PHILLIPS JOB NUMBER 0208616 ISSUE DATE 05/14/04 DRAWN BY/CHECKED BY JLS/DEB DRAWING TITLE COVER SHEET SHEET NUMBER NOR IH 1 WHITE BOX FLOOR PLAN A 1.1 SCALE: 118"=1'-0" (0 2'X 4' ACOUSTICAL LAY -IN CEILING EXHAUST FAN VENTED - - 18"W x 30"H (2/cs) MIRROR TO EXTERIOR WALL - CENTERED ABOVE LAVATORY -STAINLESS STEEL FRAME 10 42" GRAB 1'-0' lo 36"GRAB `�Q `-�9 BAR BAR p c3 io cxx_ - 6 Cn r-- _ -, �g, (� cl� 9L 19 _J -77 TOILET PAPER 17y 12" ACCESS V-3" LAVATORY 6" CENTERED ABOVE LAVATORY - STAINLESS STEEL FRAME 2'X 4' ACOUSTICAL LAY -IN CEILING 0 co DISPENSER PANEL CLEARANCE 1' 6" YL BASE 3 RESTROOM ELEV. - SIDEWALL 4 RESTROOM ELEV. - PLUMBING WALL 5 R STROOM ELEV. - SIDEWALL A 1.1 SCALE: 114"=1'-0" NOTE DIMENSIONS ARE TO WALL FINISH U.N.O. NOTE: EACH DOOR SHALL BE LABELED WITH RESPECTIVE SHOP NUMBERS (TYP. AT ALL REAR DOORS.) SCALE: 114"=1'4" A 1.1 SCALE: 1/4"=1'-0" t 2 REFLECTED CEILING PLAN NORTH A 1.1 SCALE: 1/8"=1'4" T -O" IF SLOPE GRAB BARS TO MEET ADA AND HANICAP CODES LAVATORY WI 18"x 36' WALL HUNG MIRROR, 10 TYP. CEILING PROFILE A-1.1 SCALE: N.T.S. 7 NOT USED r8NOT USED 9 FRONT DOOR DETAIL A 1.1 SCALE: 1/4"=1'-0"A-1.1 SCALE: 1/4"=1'-0" A_1 1 SCALE: 1l4"=1'-0" 6 ENLARGED RESTROOM PLAN A-1.1 SCALE: 114"=1'-0" WALL TYPES B1 3-5/8", 25 GAUGE DRY WALL METAL STUDS AT 16"o.c. TO 6" ABOVE CLG, WITH 1 LAYER OF 5/8" GYP. BD. EACH SIDE, MOISTURE RESISTANT AT TOILET INTERIOR ONLY. B2 1" METAL FURRING CHANNELS @ 24" O.C. W/ 1" RIGID INSULATION (R-5 MIN) AND 1/2" GYP. BOARD OVER TILT -UP PANEL. B3 6",25 GAUGE METAL STUDS (@ 16" O.C. WITH BATT INSULATION (R-11 MIN) AND (2) LAYERS OF 5/8" TYPE W GYP BOARD @ THE INTERIOR FACE. R1 ONE-HOUR RATED PARTITION EXTENDED TO DECK ABOVE AND CONSTRUCT WITH 3 5/8", 18 GAUGE DRY WALL METAL STUDS @ 16" O.0 WITH BATT INSULATION (MIN. R-11) AND 5/8" TYPE W (FIRE CODE) GYPSUM BOARD BOTH SIDES, FIRE TAPED TO DECK. MOISTURE RESISTANT @ TOILET INTERIOR ONLY. UL DESIGN NO. U465, ® ONE-HOUR RATED PARTITION EXTENDED TO DECK ABOVE AND CONSTRUCT WITH 3 5/8"', 18 GAUGE DRY WALL METAL STUDS @ 12" O.0 WITH BATT INSULATION (MIN. R-11) AND 5/8" TYPE W (FIRE CODE) GYPSUM BOARD BOTH SIDES, FIRE TAPED TO DECK. MOISTURE RESISTANT @ TOILET INTERIOR ONLY. UL DESIGN NO. U465, R3 ONE-HOUR RATED PARTITION EXTENDED TO DECK ABOVE AND CONSTRUCT WITH 6", 25 GAUGE DRY WALL METAL STUDS AT 16" O.0 WITH BATT INSULATION AND 5/8", TYPE W (FIRE CODE) GYPSUM BOARD BOTH SIDES, FIRE TAPED TO DECK. MOISTURE RESISTANT @ TOILET INTERIOR ONLY. R3 TWO-HOUR RATED PARTITION EXTENED TO DECK ABOVE AND CONSTRUCT WITH 6',25 GAUGE DRY WALL METAL STUDS AT WITH BATT INSULATION (MIN.. R-11)AND (2) LAYERS OF 5/8" TYPE 'X' (FIRE CODE) GYPSUM BOARD BOTH SIDES, FIRE TAPED TO DECK R4 TWO-HOUR RATED PARTITION EXTENED TO DECK ABOVE AND CONSTRUCT WITH 3 5/8",18 GAUGE DRY WALL METAL STUDS AT 16" O.C. WITH BATT INSULATION (MIN.. R-11)AND (2) LAYERS OF 5/8" TYPE 'X' (FIRE CODE) GYPSUM BOARD BOTH SIDES, FIRE TAPED TO DECK KEY WHITE BOX CONSTRUCTION CRITERIA MANUFACTURER SPECIFICATIONS FRAME (SUBJECT TO MINOR REVISION, PLEASE REFER TO LANDLORD'S DRAWINGS) GYPSUM BOARD - TAPED, FLOATED, SANDED AND READY FOR PAINT SHELL CONSTRUCTION CRITERIA U-2 GYPSUM BOARD GENERAL CONSTRUCTION SIZE (W x H x T) MATERIAL 1, CONCRETE FLOOR SLAB THRESH - ✓ MARKETPLACE AT TOWNE CENTER SHOPPING CENTER IF NEW IS REQUIRED, PROVIDE: SANFORD,FL SHELL CONSTRUCTION CRITERIA N CC -1 GENERAL CONSTRUCTION - BROOM CLEAN 1. CONCRETE FLOOR SLAB V/ 3'-0" X 7'-O" A) 4" - 3,000 PSI CONCRETE, WIRE MESH, 6 MIL VAPOR BARRIER ALUM . ALUM. TURN DOWN SLAB AT (FRONT WALL ENTRY (LOCK. REKEY AS REQUIRED BY TENANT. IF NEW IIS REQUIRED, PROVIDE: UNFILLED EXPANSION CONTROL JOINTS UNSEALED, EXPOSED CONCRETE (BROOM CLEAN) STOREFRONT LAST 15' OF SLAB AT BLACK OF SPACE TO BE LEFT UNPOURED (SHELL SCOPE) 2 2. CONCRETE SIDEWALK m O✓ A) 4" - 3,000 PSI CONCRETE (2) T-0" X T-0., TEMPERED GLASS, NO WIRE MESH ALUM. USED AT MAIN ENTRANCE ONLY. TOOLED JOINTS WITH ;2" TROWEL ACT -1 CEILING TILDGRID 3. CONCRETE TILT PANIEL - EXTERIOR WALLS (REAR AND SIDE WALLS OF z GS -1 BUILDING) WILL REMAIN AS EXPOSED CONCRETE FOR THE SHELL SPACES. NO FINISH RESTROOM NOTES: 4. STOREFRONT O✓ B) ONE SINGLE DOOR UNLESS NOTED OTHERWISE ON THE LANDLORD'S ✓ DRAWINGS) NOTES: 1. ALL FLOORING IS TO BE INSTALLED ACCORDIING TO MANUFACTURER'S WRITTEN PROCEDURES. 2. ALL NEW AND OR EXISTING SURFACES SHALL BE PREPARED AS REQUIRED TO RECEIVE NEW FINISHES. 3. CONTRACTOR TO PROVIDE TRANSITION STRIPS AT ALL CHANGES BETWEEN DIFFERENT FLOOR TYPES. 4. CONTRACTOR TO INSTALL ONLY'CUT' ACT. ALL OTHER ACT TO BE SUPPLIED AND STORED IN SPACE FOR INSTALLATION BY TENANT. CONTRACTOR SHALL SUBMIT SAMPLES TO ARCHITECT AND RECEIVE WRITTEN APPROVAL BEFORE INSTALLATION. 1. ALL TOILET FIXTURES AND MOUNTING HEIGHTS SHALL BLACK ANODIZED ALUMINUM FINISH (OR COLOR, IF SPECIFIED IN THE USED AT RESTROOM AND COMPLY WITH LOCAL HANDICAP CODES AND ADA. LANDLORD'S DRAWINGS) 2. USE SAME LAVATORY SPACING & TOILET SPACING FOR 9'- 0" HIGH W/ A 2'-O"TRANSOM AT 10'-0" AFF, OR AS NOTED RESTROOMS WITH DIFFERENT CONFIGURATIONS. DOUBLE STOREFRONT[' DOORS, ONLY AS NOTED (SEE LANDLORD'S DRAWINGS) OFFICE. STOREFRONT DOOR WITH STANDARD HARDWARE AND CLOSURE. LOCK 3. PROVIDE 2x4 BLOCKING AT ALL GRAB BAR LOCATIONS. CYLINDER TO BE KEYARLE TO REAR DOOR. DRINKING FOUNTAIN - T-0" X 7'-0" KEYED FOR MASTER KEY TO FRONT AND REAR DOOR SEE PLUMBING 4. HOT WATER AND DRAIN PIPES UNDER LAVATORIES SHALL 5. REAR DOORS DRAWINGS BE INSULATED TO PROTECT AGAINST CONTACT. THERE C) ONE SINGLE, HOLLOW METAL DOOR, UNLESS NOTED OTHERWISE IN THE SHALL BE NO SHARP OR ABRASIVE SURFACES UNDER LANDLORD'S DRAWINGS. REFER TO DOOR SCHEDULE LAVATORIES. TX T H.M. DOOR AND (FRAME, DRIP AND WEATHER-STRIP FOR TYPICAL DOOR& 5. RESTROOM WALLS TO EXTEND TO A MINIMUM HEIGHT OF STANDARD HARDWARE (PER LOCAL CODE) WITH CLOSER. LOCK CYLINDER TO HARDWARE, SHEET RA -7.1 12'-6" ABOVE FINISHED FLOOR. EXTEND TO ROOF DECK BE KEYABLE TO STOREFRONT DOOR. WHERE REQUIRED. KEYED FOR MASTER KEYING (FRONT AND REAR DOOR) PAINT ON BOTH SIDES OF THE DOOR 6. FRONT WALL ABOVE THE STOREFRONT. NOTE' DIIADMONSAM D) TAPED AND PAINT RE=ADY TO 12'-6" AFF TO FACE OFSTl1DU.1 0. E) INSULATED WITH 3-1i/2" BATT INSULATION.E ROOFING SHEET METAIL PROVIDE PAPER HOLDER 1.45 MIL TPO SINGLE-PILY, WITH 60 MIL VERTICAL FLASHING AND R-15 RIGID & MIRROR FOR FI4CH INSULATION, OR PER CODE. TOILET ROOM 2. GUTTER AND DOWNSPOUTS - FIELD PAINTED, GALVANIZED (UNLESS NOTED OTHERWISE IN THE LANDLORD'S DRAWINGS). PLUMBING/FIRE PROTECTION 1. SANITARY SEWER LATERALS STUBBED AND CAPPED 5" AFF INSIDE THE SPACE (NO VENT). 2. DOMESTIC WATER LINE STUBBED INTO EACH SPACE (OVERHEAD). 3. FIRE PROTECTION F) SPRINKLER SYSTEM„ COMPLETE PER CODE AND NFPA REQUIREMENTS FOR "SHELL". G) SPRINKLER HEADS TURNED TO AN UPRIGHT POSITION H) FIRE RISERS WILL BE PROVIDED AT A LOCATION WITHIN ONE SPACE FOR EACH BUILDING. 1) SPRINKLER DESIGN/DISTRIBUTION TO BE COMPLETED BY THE SPRINKLER SUBCONTRACTOR, SUPPLY LINES SHOULD BE LOCATED WITHIN THE STRUCTURAL JOISTS, EXCEPT AREAS WHERE THE STRUCTURAL DESIGN CAN NOT ACCOMMODATE THE SPRINKLER LINES. SPRINKLER SYSTEM DISTRIBUTION LINES TO BE INSTALLED AT 13'-0" A.F.F. OR ABOVE. HVAC 1. ROOFTOP, GAS-FIRED UNITS WITH CURBS APPROXIMATELY 1 -TON PER 350 SF (MAXIMUM SIZE PER; UNIT - 6.25 -TONS). CONTROL WIRING DROPPED INTO THE SPACE. 2. GAS LINES ARE TO BE INSTALLED OUTSIDE OF THE SHOPS, THE LINES WILL WALL TYPES B1 3-5/8", 25 GAUGE DRY WALL METAL STUDS AT 16"o.c. TO 6" ABOVE CLG, WITH 1 LAYER OF 5/8" GYP. BD. EACH SIDE, MOISTURE RESISTANT AT TOILET INTERIOR ONLY. B2 1" METAL FURRING CHANNELS @ 24" O.C. W/ 1" RIGID INSULATION (R-5 MIN) AND 1/2" GYP. BOARD OVER TILT -UP PANEL. B3 6",25 GAUGE METAL STUDS (@ 16" O.C. WITH BATT INSULATION (R-11 MIN) AND (2) LAYERS OF 5/8" TYPE W GYP BOARD @ THE INTERIOR FACE. R1 ONE-HOUR RATED PARTITION EXTENDED TO DECK ABOVE AND CONSTRUCT WITH 3 5/8", 18 GAUGE DRY WALL METAL STUDS @ 16" O.0 WITH BATT INSULATION (MIN. R-11) AND 5/8" TYPE W (FIRE CODE) GYPSUM BOARD BOTH SIDES, FIRE TAPED TO DECK. MOISTURE RESISTANT @ TOILET INTERIOR ONLY. UL DESIGN NO. U465, ® ONE-HOUR RATED PARTITION EXTENDED TO DECK ABOVE AND CONSTRUCT WITH 3 5/8"', 18 GAUGE DRY WALL METAL STUDS @ 12" O.0 WITH BATT INSULATION (MIN. R-11) AND 5/8" TYPE W (FIRE CODE) GYPSUM BOARD BOTH SIDES, FIRE TAPED TO DECK. MOISTURE RESISTANT @ TOILET INTERIOR ONLY. UL DESIGN NO. U465, R3 ONE-HOUR RATED PARTITION EXTENDED TO DECK ABOVE AND CONSTRUCT WITH 6", 25 GAUGE DRY WALL METAL STUDS AT 16" O.0 WITH BATT INSULATION AND 5/8", TYPE W (FIRE CODE) GYPSUM BOARD BOTH SIDES, FIRE TAPED TO DECK. MOISTURE RESISTANT @ TOILET INTERIOR ONLY. R3 TWO-HOUR RATED PARTITION EXTENED TO DECK ABOVE AND CONSTRUCT WITH 6',25 GAUGE DRY WALL METAL STUDS AT WITH BATT INSULATION (MIN.. R-11)AND (2) LAYERS OF 5/8" TYPE 'X' (FIRE CODE) GYPSUM BOARD BOTH SIDES, FIRE TAPED TO DECK R4 TWO-HOUR RATED PARTITION EXTENED TO DECK ABOVE AND CONSTRUCT WITH 3 5/8",18 GAUGE DRY WALL METAL STUDS AT 16" O.C. WITH BATT INSULATION (MIN.. R-11)AND (2) LAYERS OF 5/8" TYPE 'X' (FIRE CODE) GYPSUM BOARD BOTH SIDES, FIRE TAPED TO DECK DOOR SCHEDULE KEY MATERIAL MANUFACTURER SPECIFICATIONS FRAME W-1 GYPSUM BOARD - TAPED, FLOATED, SANDED AND READY FOR PAINT z U-2 GYPSUM BOARD TAPED, FLOATED, SANDED AND READY FOR PAINT SIZE (W x H x T) MATERIAL MATERIAL THRESH - ✓ ✓ IF NEW IS REQUIRED, PROVIDE: N CC -1 UNSEALED CONCRETE - BROOM CLEAN V/ V/ 3'-0" X 7'-O" TEMPERED GLASS, ALUM . ALUM. - ENTRY (LOCK. REKEY AS REQUIRED BY TENANT. IF NEW IIS REQUIRED, PROVIDE: STOREFRONT w (SHELL SCOPE) 2 m O✓ (2) T-0" X T-0., TEMPERED GLASS, ALUM. ALUM. USED AT MAIN ENTRANCE ONLY. ACT -1 CEILING TILDGRID ARMSTRONG MINA BOARD CORTEGA2A CEILING TILE! 7300 SERIES: WHITE z GS -1 EXPOSED STRUCTURE NO FINISH V/ (SHELL SCOPE) O✓ ✓ 3'-0"x T -O" NOTES: 1. ALL FLOORING IS TO BE INSTALLED ACCORDIING TO MANUFACTURER'S WRITTEN PROCEDURES. 2. ALL NEW AND OR EXISTING SURFACES SHALL BE PREPARED AS REQUIRED TO RECEIVE NEW FINISHES. 3. CONTRACTOR TO PROVIDE TRANSITION STRIPS AT ALL CHANGES BETWEEN DIFFERENT FLOOR TYPES. 4. CONTRACTOR TO INSTALL ONLY'CUT' ACT. ALL OTHER ACT TO BE SUPPLIED AND STORED IN SPACE FOR INSTALLATION BY TENANT. CONTRACTOR SHALL SUBMIT SAMPLES TO ARCHITECT AND RECEIVE WRITTEN APPROVAL BEFORE INSTALLATION. DOOR SCHEDULE HARDWARE SCHEDULE MARK PROVIDED BY INSTALL DOOR FRAME REMARKS MARK BY G.C. OWNF L.K. G.C. SIZE (W x H x T) MATERIAL MATERIAL THRESH - ✓ ✓ IF NEW IS REQUIRED, PROVIDE: OLD O V/ V/ 3'-0" X 7'-O" TEMPERED GLASS, ALUM . ALUM. USED AT MAIN ENTRANCE ONLY. ENTRY (LOCK. REKEY AS REQUIRED BY TENANT. IF NEW IIS REQUIRED, PROVIDE: STOREFRONT (SHELL SCOPE) 2 MECHAINISM. OPERATE FROM OUTSIDE BY KEY AND INSIDE BY LATCH. O✓ (2) T-0" X T-0., TEMPERED GLASS, ALUM. ALUM. USED AT MAIN ENTRANCE ONLY. PROVIDE BUTTS, PEEPHOLE, CLOSER, SILENCERS, HANDLE AT STORE FRONT V/ (SHELL SCOPE) O✓ ✓ 3'-0"x T -O" HOLLOW CORE WOOD TO BE USED AT RESTROOM AND WOOD PAINTED OFFICE. O T-0" X 7'-0" HOLLOW CORE METAL TO BE HOLLOW METAL ALUM. USED AT BACK OF THE STORE ONLY. PAINTED TO BE PAINTED (SHELL SCOPE) HARDWARE SCHEDULE MARK PROVIDED BY INSTALL �. DESCRIPTION OWNR L.K.G.C. ENTRY (LOCK. REKEY AS REQUIRED BY TENANT. O ✓ ✓ ✓ IF NEW IS REQUIRED, PROVIDE: CLOSER, MORTISED CYLINDER WITH INTERCHANGEABLE CORE COORDINATE WITH LOCKSET MECHAINISM. OPERATE FROM OUTSIDE BY KEY AND INSIDE BY LATCH. ENTRY (LOCK. REKEY AS REQUIRED BY TENANT. IF NEW IIS REQUIRED, PROVIDE: CLOSER, MORTISED CYLINDER WITH INTERCHANGEABLE CORE COORDINATE WITH LOCKSET MECHAINISM. OPERATE FROM OUTSIDE BY KEY AND INSIDE BY LATCH. O✓ ✓ 1-1/2 PAIR HINGES, MUTES, PRIVACY, CLOSER, AND FLOOR STOP. O PROVIDE BUTTS, PEEPHOLE, CLOSER, SILENCERS, HANDLE AT V/ V/ INTERIOR, LOCKSET W/ ADA LEVER BE SIZED TO SERVICE THE RTU UNITS, ONLY. THE LINES WILL BE INSTALLED FROM THE GAS METER LOCATION TO THE RTU UNITS (S). THE GAS LINES ARE NOT EXTENDED INTO THE SPACE OR SIZED TO ACCOMMODATE TENANT ITEMS. ELECTRICAL 1. CONDUIT FROM DISCONNECT FOR ELECTRICAL SERVICE, STUBBED 6" ABOVE FINISH FLOOR (CAPPED)), ADJACENT TO REAR DOOR, FOR FUTURE PANEL, LOCATION SIZED FOR 200 AMP SERVICE OR GREATER (SEE LANDLORD'S DRAWINGS). 2. CONDUIT & PULL STRING FROM ANTICIPATED PANEL LOCATION TO EXTERIOR MOUNTED J -BOX AT CANOPY FOR CANOPY SIGNAGE. 3. CONDUIT AND PULL STRING FROM ANTICIPATED PANEL LOCATION TO DISCONNECT MOUNTED ON THE RTU (S) FOR EACH SPACE. 4. 1" TELEPHONE CONDUIT WITH PULL -STRING FROM CABINET TO SPACE, STUBBED 6" ABOVE FINISHED FLOOR. MARKETPLACE AT TOWNE CENTER SHOPPING CENTER SANFORD, FL WHITE BOX CONSTRUCTION CRITERIA GENERAL CONSTRUCTION 1. DEMISING WALLS J) ONE-HOUR RATED PARTITION EXTENDED TO DECK ABOVE, CONSTRUCTED WITH 3-5/8", 18 GAUGE (METAL STUDS AT 16" O.C. WITH 5/8" TYPE "X" (FIRE CODE) GYPSUM BOARD( (ON TENANT'S SIDE OF THE WALL), FIRE TAPED TO DECK ABOVE. TAPE, SANDED AND PAINT READY TO 12'-6" ABOVE FINISHED FLOOR (AFF). 6", 25 GAUGE METAL STUDS AT 16" O.C. WITH 5/8" TYPE "X" (FIRE CODE) GYPSUM BOARD (ON TENANT'S SIDE OF THE WALL), FIRE TAPED TO DECK ABOVE- TAPE, SANDED? AND PAINT READY TO 12'-6" ABOVE FINISHED FLOOR (AFF). 2. REAR WALL A) UNPAINTED/ EXPOSED CONCRETE TILT -UP PANELS W R-5 RIGID INSULATION AND 5/8" GYP. BOARD ON 1"Z FURRING CHANNELS, PAINT READY TO 12'-6" AFF (FIRE TAPED TO DECK ABOVE). B) TILT -UP PANELS WALLS IN TOILET ROOMS WILL BE COVERED WITH MOISTURE RESISTANT (GYPSUM BOARD ON 1" Z FURRING CHANNELS WITH MINIMUM R-11 RIGID INSULATION, PAINT READY TO 8"6" AFF. 3. ACOUSTICAL CEILING; A) 2'0"X4'0" STANDARD GRID SYSTEM, WITH 5/8" NON -DIRECTIONAL FISSURED, FIBERGLASS CEILING PANELS AT 12'-0" AFF TYPICAL AND 8'-0" AFF AT RESTROOM. B) LANDLORD TO INSTAILL "CUT" CEILING TILES ONLY, ALL FULL 2X4 CEILING TILES WILL BE STOCKPIILED IN SPACE FOR TENANT'S INSTALLATION, 4. TOILET ROOMS A) 3'0" X TO" PREHUNG HOLLOW CORE WOOD DOOR AND FRAME UNIT WITH LEVER HANDLE HARDWARE (PRIMER PAINT). B) UNSEALED EXPOSED) CONCRETE FLOOR, BROOM CLEANED. C) WALL HUNG 18"X36" MIRRORS, WALL MOUNTED (HEIGHT PER CODE), ABOVE LAVATORY. D) ONE TOILET PAPER HOLDER MOUNTED 1'5" TO 17" AFF PER TOILET. E) GRAB BARS PER CODE. F) FLOOR MOUNTED, OWERHEAD BRACED, BAKED ENAMEL PARTITIONS, IF REQUIRED PER CODE. G) QUANTITY OF RESTR;OOMS/FIXTURES AS INDICATED ON LANDLORD'S DRAWINGS. H) TANK -TYPE HANDICAP ACCESSIBLE WATER CLOSETS. 1) WALL HUNG LAVATORIES WITH HANDICAP ACCESSIBLE FAUCET. PROVIDE STRAINER AND INSULATED PIPE GUARDS. J) ONE EXHAUST FAN, PER RESTROOM - K) ONE LIGHT SWITCH PER RESTROOM. L) ONE WALL MOUNTED FLUORESCENT FIXTURE. NOTE: ENLARGED RESTROOM DETAILS AND DRAWINGS ARE PROVIDED FOR GENERAL /NFORMATIOhV ONLY. ACTUAL RESTROOM CONFIGURATIONS AREAS SHOWN ON THE FLOOR' PLANS FOR YOUR SPACE. PLUMBING/FIRE PROTEICTION 1. WALL HUNG ELECTRIC WATER FOUNTAINS (AS INDICATED IN LANDLORD'S DRAWINGS AND/OR REQUIRED BY CODE FOR STANDARD RETAIL USE.) 2. MOP SINK PROVIDED„ WHERE REQUIRED BY CODE. 3. 10 GAL. ELECTRIC WAITER HEATER. HVAC 1. PROVIDE DISTRIBUTION FROM ROOF -TOP UNIT(S). A) NON -DIRECTIONAL DIFFUSERS B) ONE RETURN AIR GRIILL, PER RTU C) REFER TO LANDLORD'S DRWINGS FOR STANDARD DUCTWORK DISTRIBUTION. 2. PROVIDE A STANDARD HEAT/COOL THERMOSTAT MOUNTED 5'0" AFF IN RETAIL SPACE. ELECTRICAL 1. PANEL AND SERVICE 'TO BE 1201208 VOLT, THREE (3) PHASE. K) 0- 999 SF 100 AMP PANEL, WITH CONDUIT FOR 200 AMP SERVICE L) 1,000 - 3,999 SF 200 AMP PANEL, WITH CONDUIT FOR 200 AMP SERVICE M) 4,000 - 5,999 SF 300 AMP PANEL, WITH CONDUIT FOR 400 AMP SERVICE N) 6,000 - 7,999 SF 400 AMP PANEL, WITH CONDUIT FOR 400 AMP SERVICE NOTE: WIRE MAYBE COPPER OR ALUMINUM 2. OUTLETS WALL MOUNTED DUPLEX OUTLETS AT 20'0" O.C. ALONG SIDE WALLS, 15" 1'3" AFF ONE (1) DUPLEX OUTLET MOUNTED 4'6" AFF AT TELEPHONE BOARD. ONE (1) GFI OUTLET IN EACH RESTROOM. 3. LIGHTING A) ONE (1) 2'0"X4'0" FOUIR-TUBE LAY -IN FLUORESCENT FIXTURE - ONE (1) FIXTURE, PER 96 SF FOR 80% FOR THE SPACE AND ONE (1) FIXTURE PER 200 SF FOR THE REMAINING 20% OF THE SPACE. B) ONE (1) 24" FLUORESCENT TWO -LAMP LIGHT FIXTURE, WALL MOUNTED AT 6" ABOVE THE VANITY MIRROR IN EACH RESTROOM. C) EXIT LIGHT AT FRONT AND REAR DOORS AND WALL MOUNTED EMERGENCY LIGHTS, AS REQUIRED BY CODE (FOR THE STANDARD WHITE BOX FINISH). D) ONE (1) LIGHT SWITCH FOR EACH RESTROOM. 3. TELEPHONE PROVIDE W X 2'0" X 2'U" F.R.T. PLYWOOD BACKBOARD ON REAR WALL, AT TELEPHONE CONDUIT LIOCATION. REVISION ## 38 SUMMARY A. SHEET ADDED PHILLIPS 00-00� 11-ofts P A R T N E R S H I P Architecture " Interior Design " Planning Phone 770.3941616 770.394.1314 RF 1RE K J I L C D G H RC '4 ANCHOR g E F CONSULTANT SEAL REVISIONS # DATE DESCRIPTION ® -10/18/04 SHOPS WHITE BOX This document is 9 Philrips Partnership, PC and is considered an Instrument of Service and is solely for use with respect to the project as indicated below- All rights reserved. This document may not be reproduced without the prior written consent of Phillips Partnership, PC - TENANT STANDARD WHITE BOX SHOP 1081 W.P. BALL BOULEVARD PROD ECT THE MARKETPLACE AT SEMINOLE TOWNE CENTER 0 SANFORD, FLORIDA CLIENT NORTH AMERICAN PROPERTIES NORTH AMERICAN PROPERTIES -ATLANTA 1080 HOLCOMB BRIDGE ROAD BUILDING 200, SUITE 150 ROSWELL, GA 30075 TEL (770) 645-6566 FAX (770) 643-9540 PHILLIPS JOB NUMBER 0208616 ISSUE DATE 05/14/04 DRAWN BY/CHECKED BY ALE/DEB DRAWING TITLE FLOOR PLAN, DETAILS, & SPECS SHEET,,NUMB_T 38 A A=1 .1 H.V.A.C. GENERAL NOTES 1. ALL MECHANICAL EQUIPMENT AND INSTALLATIONS SHALL CONFORM WITH THE REQUIREMENTS OF THE 2000 FLORIDA BUILDING CODE (MECHANICAL), THE 2001 FLORIDA BUILDING CODE, THE 2000 FLORIDA ENERGY CODE, THE 2000 EDITIONS OF NFPA 90A & 101, UNDERWRITERS LABORATORIES (OR ETL) AND ALL APPLICABLE LOCAL CODES AND ORDINANCES. 2. PRIOR TO PURCHASING ANY MATERIALS OR STARTING ANY WORK, CONTRACTOR SHALL FIELD VERIFY ALL CONDITIONS, DUCTWORK SIZES AND LOCATIONS, EQUIPMENT, ETC. SHOWN ON THE DRAWINGS OR AFFECTING THIS WORK AND SHALL REPORT ANY DEVIATIONS TO THE ARCHITECT. 3. SHOP DRAWINGS SHALL BE SUBMITTED TO AND APPROVED BY THE ARCHITECT PRIOR TO ORDERING, PURCHASING, OR FABRICATING ANY MECHANICAL EQUIPMENT. SHOP DRAWINGS SHALL INCLUDE: ALL EQUIPMENT SCHEDULED OR SPECIFIED ON THE DRAWINGS; DUCTWORK DRAWN TO 1/4" SCALE OR THE SCALE SHOWN ON THE DRAWINGS. 4. CONTRACTOR SHALL COORDINATE ELECTRICAL CHARACTERISTICS AND REQUIREMENTS OF ALL MECHANICAL EQUIPMENT WITH ELECTRICAL DRAWINGS PRIOR TO ORDERING EQUIPMENT OR SUBMITTING SHOP DRAWINGS, AND SHALL FURNISH EQUIPMENT WIRED FOR THE VOLTAGES SHOWN THEREIN. 5. ALL MECHANICAL EQUIPMENT REQUIRING ELECTRICAL POWER SHALL BE INSTALLED WITH DISCONNECT SWITCHES AT EACH PIECE OF EQUIPMENT. COORDINATE SWITCH TYPE (FUSED OR NON-FUSED) WITH EQUIPMENT CHARACTERISTICS, MANUFACTURER'S RECOMMENDATIONS AND ELECTRICAL DRAWINGS. 6. ALL REQUIRED CONTROL WIRING (INCLUDING POWER WIRING REQUIRED FOR CONTROL PANELS, DEVICES, ETC.) NOT SHOWN ON THE ELECTRICAL DRAWINGS SHALL BE INCLUDED AS PART OF THE MECHANICAL WORK. WIRING IN HVAC PLENUM SPACES SHALL BE INSTALLED ACCORDING TO CODE REQUIREMENTS. 7. UNLESS NOTED OTHERWISE, STARTERS, TRANSFORMERS, CONTROLS AND CONTROL WIRING REQUIRED FOR ALL MECHANICAL SYSTEMS SHALL BE FURNISHED AND INSTALLED BY THE MECHANICAL CONTRACTOR. 8. ALL FANS SUPPLYING MORE THAN 2000 CFM OF AIR TO ANY SPACE AND ALL RECIRCULATING FAN SYSTEMS SERVING AREAS OF EGRESS SHALL BE INSTALLED WITH A SMOKE DETECTOR IN THE SUPPLY DUCTWORK. DUCT SMOKE DETECTORS SHALL BE INSTALLED IN THE RETURN AIR PATH OF AIR DISTRIBUTION SYSTEMS UTILIZING,A COMMON SUPPLY AND/OR RETURN AIR PLENUM WITH A COMBINED DESIGN CAPACITY GREATER THAN 2000 CFM. THE SMOKE DETECTOR SHALL BE WIRED TO STOP THE FAN UPON DETECTION OF SMOKE, AND SIGNAL THE BUILDING FIRE ALARM CONTROL PANEL. THE SMOKE DETECTOR SHALL BE FURNISHED BY THE ELECTRICAL CONTRACTOR, MOUNTED IN THE DUCT BY THE MECHANICAL CONTRACTOR, AND WIRED BY THE ELECTRICAL CONTRACTOR. 9. INSTALL FIRE DAMPERS IN ALL RATED THROUGH WALLS, FLOOR AND CEILING PENETRATIONS. REFER TO THE ARCHITECTURAL DRAWINGS FOR LOCATIONS OR RATED AREAS. PROVIDE ACCESS DOORS IN DUCTWORK AT EACH FIRE DAMPER LOCATION. INSTALL SMOKE DAMPERS IN ALL DUCT PENETRATIONS THROUGH SMOKE RATED WALLS. WHERE DUCTS PENETRATE WALLS THAT CARRY BOTH FIRE AND SMOKE RATINGS, THE DAMPERS INSTALLED SHALL BE COMBINATION FIRE AND SMOKE DAMPERS. ALL DAMPERS SHALL BE U.L. 555 LABELED. 10. ALL MECHANICAL EQUIPMENT SHALL BE INSTALLED ACCORDING TO MANUFACTURER'S RECOMMENDATIONS. 11. ALL MECHANICAL EQUIPMENT AND SYSTEMS SHALL BE GUARANTEED FOR A PERIOD OF ONE YEAR AFTER ACCEPTANCE BY OWNER. 12. ALL HVAC COMPRESSORS SHALL HAVE EXTENDED 10 YEAR MANUFACTURER'S WARRANTY. 13. COORDINATE EXACT LOCATION OF ROOFTOP AIR CONDITIONING UNITS WITH ARCHITECTURAL AND STRUCTURAL DRAWINGS. 14. SUPPLY, RETURN AND O.A. DUCTWORK SHALL BE CONSTRUCTED OF GALVANIZED SHEET METAL AS RECOMMENDED IN SMACNA LOW PRESSURE DUCT CONSTRUCTION STANDARDS LATEST EDITION. T T E TTI N. ALL JOINTS AND SEAMS IN ALL SHEEETMETAL DUCTWORK SHALL BE SEALED WITH DUCT SEALER. 15. SHEET- METAL SUPPLY, RETURN, & O.A. DUCTWORK SHALL BE INSULATED WITH 2" THICK FIBERGLASS, 3/4 LB/FT3 DENSITY, DUCT INSULATION WITH FOIL VAPOR BARRIER, U.L. LISTED, R-6 MINIMUM. 16. EXHAUST DUCTWORK SHALL BE SHEET METAL AND SHALL NOT BE INSULATED UNLESS NOTED OTHERWISE. 17. ALL DUCTWORK SHALL BE SUPPORTED BY THE BUILDING STRUCTURE AND SHALL NOT REST ON CEILING TILES OR CEILING STRUCTURE. DUCT SUPPORTS AND ATTACHMENT TO STRUCTURE SHALL BE AS PER SMACNA STANDARDS. 18. EXPOSED ROUND DUCTWORK SHALL BE MEDIUM PRESSURE SPIRAL TYPE, UNITED MCGILL OR EQUAL. 19. FLEXIBLE DUCTWORK SHALL BE THERMAFLEX M -KE (U.L. 181 LISTED, CLASS 1 FLEXIBLE AIR DUCT), R VALUE = 6.0 MINIMUM OR AS REQUIRED BY LOCAL ENERGY CODE. AIR CONNECTORS ARE NOT ACCEPTABLE. SIZE TO MATCH DEVICE NECK, PROVIDE ROUND GALVANIZED STEEL DUCT RUNOUTS TO MAINTAIN A MAXIMUM FLEXIBLE DUCT LENGTH OF 4'0". FLEXIBLE DUCTWORK SHALL BE INSTALLED AS STRAIGHT AS POSSIBLE AND SHALL BE ROUTED AND SUPPORTED WITHOUT FORMING CRIMPS OR OTHER AIR FLOW RESTRICTIONS. PROVIDE SQUARE TO ROUND ADAPTERS OR BOOTS TO CONNECT TO AIR DEVICE NECK WHEN REQUIRED. 20. ROUND AND FLEXIBLE DUCTWORK SHALL BE CONNECTED TO MAIN DUCTS WITH SPIN?IN FITTINGS WITH SCOOP AND BALANCING DAMPER. 21. SHEET METAL DUCTWORK SHOWN AS BEING INTERNALLY LINED SHALL BE LINED WITH 1" THICK 3 LB./CU. FT. DENSITY DUCTLINER (MINIMUM R VALUE _ 4.0 OR AS REQUIRED BY APPLICABLE ENERGY CODE), CERTAINTEED "'TOUGHGARD" OR EQUAL BY KNAUF OR JOHNS -MANVILLE, PRODUCTS BY OWENS-CORNING ARE NOT ACCEPTABLE. LINE ALL DUCTWORK A MINIMUM OF 10'0" DOWNSTREAM OF ALL AIR HANDLING UNI'IS, FAN COIL UNITS AND TERMINAL UNITS. THE LEADING EDGE OF THE DUCT LINER SHALL HAVE SHEETMETAL NOSING. 22. PORTIONS OF DUCTWORK VISIBLE THROUGH AIR DISTRIBUTION DEVICES IN FINISHED AREAS SHALL BE PAINTED FLAT BLACK. 23. DUCTWORK DIMENSIONS SHOWN ON THE DRAWINGS ARE INSIDE CLEAR DIMENSIONS. 24. CONDENSATE FROM ALL AIR CONDITIONING EQUIPMENT SHALL BE TRAPPED AND ROUTED TO THE NEAREST ROOF DRAIN/GUTTER. CONDENSATE PIPING SHALL BE SCHEDULE 40 PVC. CONDENSATE SHALL BE PUMPED AS REQUIRED. 25. AFTER CONSTRUCTION, THE ENTIRE HVAC SYSTEM SHALL BE TESTED, ADJUSTED, AND BALANCED TO DELIVER THE AIR QUANTITIES SHOWN ON THE DRAWINGS. TEST AND BALANCE REPORT SHALL BE PREPARED BY AN INDEPENDENT TESTING AND BALANCING CONTRACTOR WHO IS A MEMBER OF THE AABC OR NEBB. REPORT SHALL INCLUDE THE FOLLOWING TEMPERATURE READINGS, IN ADDITION TO AIR FLOWS: AIR LEAVING DIFFUSERS, AIR LEAVING HVAC UNIT, OUTSIDE AMBIENT AT TIME OF TEST. SUBMIT CERTIFIED TEST AND BALANCE REPORT TO OWNER/ARCHITECT FOR APPROVAL 26. ANY EXISTING WALL, FLOOR, OR CEILING SURFACE THAT IS DISTURBED DURING THE COURSE OF THE HVAC WORK SHALL BE REPAIRED TO MATCH NEW AND/OR EXISTING CONDITIONS. 27. CONTRACTOR SHALL COORDINATE THE INSTALLATION OF ALL MECHANICAL EQUIPMENT DUCTWORK ETC. TO FIT WITHIN THE SPACE ALLOWED BY THE ARCHITECTURAL AND STRUCTURAL CONDITIONS. CUTTING OR OTHERWISE ALTERING ANY STRUCTURAL MEMBERS SHALL NOT BE PERMITTED WITHOUT WRITTEN PERMISSION FROM THE ARCHITECT. 28. PROVIDE ACCESS PANELS IN NON -ACCESSIBLE CEILINGS AND IN WALL STRUCTURE TO ALLOW ADEQUATE ROOM FOR MAINTENANCE OF EQUIPMENT AND BALANCING OF SYSTEM. ACCESS PANELS IN CEILING AND WALLS SHALL BE PROVIDED WHERE SHOWN ON THE DRAWINGS OR NECESSARY TO ACCESS DAMPERS, VALVES, ETC. COORDINATE EXACT LOCATION OR ALL ACCESS PANELS WITH THE ARCHITECT DURING THE SHOP DRAWING PROCESS. 29. MOUNT THERMOSTATS AND/OR SENSORS 4'0" AFF UNLESS NOTED OTHERWISE. 30. ALL ROOFTOP MOUNTED EQUIPMENT SHALL BE INSTALLED LEVEL ON AND ANCHORED TO MINIMUM 12" HIGH INSULATED ROOF CURBS. CONTRACTOR SHALL COORDINATE ROOF SLOPE AND ACTUAL CURB HEIGHTS WITH ARCHITECTURAL DRAWINGS. ALL REFERENCES TO ROOF HEIGHTS REFER TO HEIGHTS ABOVE FINISHED ROOF SURFACE. 31. LOCATIONS OF GRILLES, REGISTERS, & DIFFUSERS SHOWN ON THE DRAIN NGS ARE APPROXIMATE. COORDINATE EXACT LOCATIONS WITH LIGHTS, CEILING GRID, ETC. AND ARCHITECTURAL REFLECTED CEILING PLAN. 32. ROOFTOP HVAC UNITS SHALL BE INSTALLED SUCH THAT ROOF DECK IS COMPLETE AND CONTINUOUS UNDER BOTTOMS OF HVAC UNITS, AND SHALL BE CUT ONLY FOR UNIT SUPPLY AND RETURN OPENINGS. SPACE BETWEEN ROOF DECK AND BOTTOM OF ROOFTOP HVAC UNITS (INSIDE OF ROOF CURBS) SHALL BE FILLED WITH HIGH DENSITY ACOUSTICAL INSULATION. 33. ALL MECHANICAL EQUIPMENT SHALL BE LABELED WITH BAKELITE NAMEPLATE WITH 2" HIGH WHITE LETTERS ON A BLACK BACKGROUND, NAMEPLATE SHALL SHOW TENANT AND/OR SUITE SERVED. PACKAGED ROOFTOP H.V.A.C. UNITS S. P. NECK DRIVE MOTOR MAX. DUTY MODEL REMARKS MATERIAL A TITUS PAS 24X24 TAG NOMINAL MODEL NO. AIRFLOW E.S.P. MAXIMUM MAXIMUM TOTAL SENSIBLE COOLING KW OPERATING ACCESSORIES TONNAGE (CFM) (IN. W.C.) O.A. FAN COOLING COOLING EFFICIENCY ELECTRIC WEIGHT TRHERMAL OVERLOAD PROTECTION 2. DISCONNECT SWITCH/PLUGS CAPABILITY H.P. (MBH) (MBH) .............. ................ ............ WHITE HEATER (LBS.) D RTU -3 3 CARRIER 50TME004 1200 1.0' 25% 1 36.6 26.0 10.0 SEER 12.3 1 485 LBS. 1-8 RTU -4 4 CARRIER 50TME005 1600 1.0" 25% 1-1/2 50.5 35.6 10.0 SEER 15.8 ? 495 LBS. 1-8 RTU -5 5 CARRIER 50TME006 2000 1.0" 25% 2 60.9 45.3 10.0 SEER 15.8 515 LBS. 1-8 RTU -6 6-1/2 CARRIER 50TME007 2400 1.0 25% 3 76.2 56.8 10.3 EER 15.8 635 LBS. 1-8 NOTE: EQUAL PRODUCTS BY KRUEGER, METAL-AIRE. COOLING CAPACITIES ARE BASED ON 95T DB AMBIENT, 80-F DB/'&'F WB EAT. ACCESSORIES: 1. PREFABRICATED FULL- PERIMETER ROOF CURB, 14 INCH HIGH (COORDINATE SLOPE WITH ARCHITECTURAL) 2. FACTORY -INSTALLED ELECTRIC HEATERS & CONTROLS 3. SINGLE -POINT POWER CONNECTION W/NON-FUSED DISCONNECT 4. GFCI CONVENIENCE OUTLET (120 VOLT) 5. HIGH EFFICIENCY BLOWER MOTOR 6. LOW AMBIENT COOLING TO 45T. 7. 0-25% OUTSIDE AIR HOOD WITH TWO -POSITION DAMPER 8. ELECTRONIC DIGITAL THERMOSTAT, AUTOMATIC -CHANGEOVER, PROGRAMMABLE 9. SMOKE DETECTOR (SEE GENRAL NOTES) SELECTIONS BASED ON EQUIPMENT MANUFACTURED BY CARRIER. APPROVED EQUALS BY TRANE, YORK. FAN AND VENTILATOR SCHEDULE TAG TYPE CFM S. P. NECK DRIVE MOTOR MAX. DUTY MODEL REMARKS MATERIAL A TITUS PAS 24X24 WATTS RPM YES MANUF. STD - EF 1 ............................................ CABINET CENTRIFUGAL ........................................................................................... 85 ................................... r...................................... 0 25 ............................... TITUS PAS I................................................... DIRECT 50 1200 EXHAUST PENN ZEPHYRETTE: ZT 1,2,3,4,5 REMARKS/ACCESSORIES: STD .... WHITE 1.. CABINET CENTRIFUGAL EXHAUST FAN WITH INTEGRAL TRHERMAL OVERLOAD PROTECTION 2. DISCONNECT SWITCH/PLUGS ......................................... ..................................................... l 10"b ........... YES 3. INTEGRAL GRAVITY BACKDRAFT DAMPER .............. ................ ............ WHITE 4. CONTROLLED VIA WALL SWITCH D ................................................................................................................................................................................................................................................F........................................................................................;................................................................................................................................................................................. TITUS PAS 5. DISCHARGE TO WALL OR ROOF CAP W/SCREEN & FLASHING (SEE PLANS) SELECTIONS BASED ON EQUIPMENT MANUFACTURED BY PENN VENTILATOR. EQUALS BY COOK, GREENHECK. E: I AIR DISTRIBUTION SCHEDULE TAG MODEL SIZE NECK DAMPER FINISH DUTY MATERIAL A TITUS PAS 24X24 6"� YES MANUF. STD WHITE SUPPLY STEEL ........................ ..................:............................. B ............................... TITUS PAS I................................................... .... ........................................................................... ....... 24X24 ....................... ........................................................ 8"0 ........................... YES ............................................................................. MANUF. STD .... WHITE ....... SUPPLY STEEL .............. ............................. C TITUS PAS ............. .................................................................................. 24X24 ......................................... ..................................................... l 10"b ........... YES ................ ...................... MANUF. ................ STD .............. ................ ............ WHITE .......................... ........................... SUPPLY ..... ..................................................................................... ................ STEEL D ................................................................................................................................................................................................................................................F........................................................................................;................................................................................................................................................................................. TITUS PAS 24X24 12"0 YES MANUF. STD WHITE SUPPLY STEEL E TITUS PAS 24X24 14"0 YES MANUF. STD WHITE SUPPLY STEEL F TITUS 50F 24X24 --- NO MANUF. STD WHITE RETURN ALUMINUM COORDINATE MOUNTING FRAME REQUIREMENTS WITH ARCHITECTURAL REFLECTED CEILING PLANS. SELECTIONS BASED ON EQUIPMENT MANUFACTURED BY TITUS. EQUAL PRODUCTS BY KRUEGER, METAL-AIRE. CONNECT FLEX DUCT ENDS TO SHEET METAL PIPE TO NEAREST DUCT AND DIFFUSER NECK WITH NYLON TIES. ROOF GUTTER INTERIOR (LINER AND EXTERIOR INSULATION OF FLEX DUCT TO BE TIED INDIVIDUALLY. / INSTALL USING TENSIONING TOOL AS PER TOTAL TRAP HEIGHT MANUFACTIURER'S RECOMMENDATIONS. TOTAL TRAP HEIGHT = X + H + 1.5 D WHERE: H = AT LEAST 1" PLUS CASING SP D = PIPE DIAMETER CONDENSATE FROM ROOFTOP AIR CONDITIONING EQUIPMENT SHALL BE TRAPPED AND ROUTED TO DISCHARGE INTO THE NEAREST GUTTER/DOWNSPOUT - COORDINATE GUTTER LOCATIONS WITH ARCHITECTURAL ROOF PLAN. CONDENSATE DRAIN PIPING TO BE ROUTED ON ROOF, SUPPORTED ON BLOCKING AT MAXIMUM 8 FOOT CENTERS, AND SLOPED AT 1/8" PER FOOT MINIMUM. CONDENSATE PIPING SHALL BE SCHEDULE 40 PVC. MULTIPLE UNITS MAY HAVE CONDENSATE PIPING MANIFOLDED INTO A COMMON PIPE TO DRAIN. UNLESS INDICATED OTHERWISE ON DRAWINGS, CONDENSATE DRAIN PIPING SHALL BE SIZED PER THE FOLLOWING CRITERIA: 3/4" FOR UP TO 2 TON CONNECTED COOLING LOAD; 1" FOR 2 THRU 5 TONS; 1-1/4" FOR 5 THRU 30 TONS; 1-1/2" FOR 30 THRU 50 TONS; 2" FOR 50 TO 170 TONS; 3" FOR 170 TO 300 TONS; 4" FOR 300 THRU 430 TONS. CONDENSATE DRAIN TRAP DETAIL 1 NOT TO SCALE ROUND SHEET METAL DUCT. DIAMETER AS INDICATED ON PLANS - TRUNK DUCT/ SPIN -IN FITTING - WITH DAMPER & SCOOP FOR SUSPENDED CEILING. SUPPLY AIR APPLICATIONS, SEE ARCH. PLANS PLAIN SPIN -COLLAR FOR FOR TYPE. RETURN APPLICATIONS NYLON TIES INTERIOR LINER PRE -INSULATED FLEXIBLE DUCTWORK. SEE SPECIFICATIONS. LENGTH NOT TO EXCEED 4'-0". PROVIDE SUPPORT PER SMACNA STANDARDS. INSTALL FREE OF KINKS & SAGS. SUPPLY DIFFUSER OR RETURN AIR GRILLE RUN -OUT CONNECTION DETAIL NOT TO SCALE WHITE BOX FLOOR PLAN - H.V.A.C. SCALE: 1/8* = 1'-0w CONDENSER FAN DISCHARGE OUTDOOR AIR INTAKE/ECONOMIZER DISCONNECTSEE HOOD (WHERE APPLICABLE) ELECTRICAL .) r� y PREFABRICATED ROOF CURB POWER WIRING (SEE ELECTRICAL) BAROMETRIC, RELIEF HOOD (WHERE APPLICABLE) CONIDENSATE DRAIN TO BE (ROUTED ON ROOF TO INEAREST ROOF DRAIN UNLESS NOTED OTHERWISE r ROOF DECK THERMOSTAT WIRING SUPPLY AIR DUCT TRAP RETURN AIR DUCT NOTE: ALL CONNECTIONS AND SERVICES MUST BE INSIDE THE PERIMETER CURB. DISCONNECT SWITCHES, BRACKETS, AND CONDUIT MUST BE CLEAR OF ALL UNIT PANELS AND AIR FLOW. BRACKETS MUST BE TO STRUCTURAL MEMBERS OF UNIT. ANOT OOFTOP AIR CONDITIONER DETAIL TO SCALE PHILLIPS 00000-10 on P A R T N E R S H I P Architecture - Interior Design - Planning 770.394.1616 770.3941314 RF RE K J I s E F H C FA: ANCHOR g C D CONSULTANT Jordan & Skala Engineers, Inc. rl Project Number - 0410070 [71l 5365 OAKBROOK PARKWAY, NORCROSS, GA 30093 PHONE (770)447-5547 FAX(770)448-0262 EMAIL jse@jordanskalo.com 1 1 COPYRIGHT © 2004 JORDAN & SKALA ENGINEERS INC. SEAL REVISIONS -1- # 1-- # DATE DESCRIPTION This document is © Phillips Partnership, PC and is considered an Instrument of Service and is solely for use with respect to the project as indicated below. All rights reserved. This document may not be reproduced without the prior written consent of Phillips Partnership, PC. TENANT STANDARD WHITE BOX SHOP 1081 W.P. BALL BOULEVARD PROJECT THE MARKETPLACE AT SEMINOLE TOWNE CENTER 0 SANFORD, FLORIDA CLIENT NORTH AMERICAN PROPERTIES NORTH AMERICAN PROPERTIES - ATLANTA 1080 HOLCOMB BRIDGE ROAD BUILDING 200, SUITE 150 ROSWELL, GA 30075 TEL (770) 645-6566 FAX (770) 643-9540 PHILLIPS JOB NUMBER 0208616 ISSUE DATE 10/18/04 DRAWN BY/CHECKED BY MLVV/GMS DRAWING TITLE WHITE BOX FLOOR PLAN - H.V.A.C. SHEET NUMBER DIELECTRIC UNION (TYP ASME T&P RELIEF VALV DISCHARGE FULL SIZE j & TERMINATE 6" MIN. / 1 1/2" HIGH SAFETY P 1" DRAIN ROUTE A/C i! TERMINATE 6" MIN. AFG WHITE BOX FLOOR PLAN SCALE: 1/410 = 11-0" CEILING SUSPENDED EWH SCALE: N.T.S. __ GALLON EXPANSION TANK VACUUM RELIEF GATE VALVE (TYP.2) 1/2" CW SUPPLY 1/2" HW OUTLET 3/4" CADMIUM PLATED ALL THREAD ROD WITH LOCK WASHERS AND DOUBLE NUTS (TYPA) SOLDER SEAMS WATER TIGHT CROSS BREAK BOTTOM OF PAN TO DRAIN POINT 2" X 2" X 1/4" GALVANIZED ANGLE IRON FRAME DRAIN VALVE WATER HEATER SCHEDULE SYMBOL LOCATION/ STORAGE ` GPH ABOVE CEILING ELECTRICAL CRITERIA NOTES FIXTURE # FIXTURE TYPE MODEL NO. CAPACITY REC./TEMP. RISE OUTLET KW B/F CONNECTION SUPPLY GALLONS RISE TEMPERATURE INPUT 4" EWH-1 ABOVE CEILING/ 2 1/2 8.3/75'F 120'F 1.5 1-3 1/2" ELC-2 - -- - ELECTRIC WATER COOLER 1 1/4" --- 1/2" NOTES: - S Sy 1. PROVIDE T&P RELIEF VALVE AND VACUUM RELIEF VALVE - _S__ S,W 2. PROVIDE GATE/BALL VALVES WITH UNIONS AND DIELECTRIC FITTINGS ON WATER INLET AND OUTLET CONNECTIONS. 3. DESIGN BASIS: A.O. SMITH, POINT -OF -USE, SINGLE ELEMENT OPERATION. 0- PLUMBING FIXTURE SCHEDULE FIXTURE SELECTION IS BASED ON KOHLER MODELS UNLESS OTHERWISE NOTED, APPROVED EQUAL MANUFACTURERS AS FOLLOWS: FIXTURES: ELDAY, JUST FAUCETS & TRIM: KOHLER, AMERICAN STANDARD, BRASSCRAFT, DELTA, MCGUIRE, SANITARY DASH, ZURN P1H WATER CLOSET - FLOOR MOUNTED - TANK - ELONGATED - SEAT W/COVER - PUBLIC: AMERICAN STANDARD 2216.143 - FLOOR MOUNT, TANK TYPE, COMBINATION FIXTURE, 1.5 GALLON FLUSH, VITREOUS CHINA, ELONGATED SIPHON JET, CHROME PLATED ACTUATOR, BOLT CAPS, WHITE. SEAT - BENEKE 520-HPSS COMMERCIAL GRADE SOLID PLASTIC, ELONGATED. CLOSED FRONT SEAT WITH COVER, STAINLESS STEEL POSTS AND SELF-SUSTAINING HINGES, WHITE. SUPPLY - BRASSCRAFT OCR1912 - 1/2" O.D. X 3/8" O.D. ANGLE STOP, WHEEL HANDLE, WALL FLANGE, CHROME PLATED. P2WH LAVATORY - WALL HUNG - GRID DRAIN: KOHLER K-2005 21" X 18" WALL HUNG LAVATORY, 4" CENTERS, CONCEALED ARMS, FRONT OVERFLOW AND BACKSLASH, WHITE. FAUCET.- KOHLER K-15199 SINGLE LEVER HANDLE, 4" CENTERS, FLOW RESTRICTOR, WITH GRID DRAIN REPLACEABLE CERAMIC DISC CARTRIDGE, AERATOR, 1 1/4" TAILPIECE, CHROME FINISH. SUPPLY - BRASSCRAFT SR1712A - 1/2" O.D. X 3/8" O.D. ANGLE SUPPLY, LOOSE KEY STOP, WALL FLANGE, CHROME PLATED. TRAP - MCGUIRE 8902 - 1 1/4" X 1 1/2", 17 GAUGE ADJUSTABLE TRAP WITH CLEANOUT AND WALL FLANGE, CHROME FINISH. DRAIN - MCGUIRE 155 -WC - 1 1/4", 17 GAUGE OFFSET DRAIN WITH OPEN GRID STRAINER, CHROME PLATED. LAVATORY WASTE TRAP PRIMER - JAY R. SMITH 2698 - 1 1/4", 17 GAUGE ADJUSTABLE WITH CLEANOUT AND WALL FLANGE, TRAP PRIMER TUBING WITH WALL FLANGE, CHROME PLATED. PROVIDE IN LIEU OF STANDARD TRAP AT LOCATIONS INDICATED ON DRAWINGS. INSULATION KIT - HANDI LAV -GUARD MODEL 102 AND 105 - SELF FASTENING, VINYL INSULATION COVERS FOR DRAIN, TRAPS, AND SUPPLY PIPING WITH ACCESSIBLE ANGLE VALVE INSULATION COVER, WHITE. CARRIER - SMITH 700 SERIES - ADJUSTABLE FLOOR SUPPORT WITH CONCEALED ARMS. P813 ELECTRIC WATER COOLER: OASIS P8ACSL WALL MOUNTED BARRIER FREE BI -LEVEL COOLERS, FRONT PUSHBUTTON OPERATION, HEAVY GAUGE STAINLESS STEEL, UNIT TO PROVIDE MINIMUM 8 GPH OF 50'F WATER WITH 90'F AMBIENT AND 80'F SUPPLY WATER TEMPERATURE, VINYL FINISH. SUPPLY - MCGUIRE ST07 - 1/2" O.D. X 3/8" O.D., WHEEL HANDLE STOP. TRAP - MCGUIRE 8902 - 1-1/4" X 1-1/2", 17 GAUGE ADJUSTABLE TRAP WITH CLEANOUT, CHROME FINISH. PLUMBING LEGEND FIXTURE SCHEDULE DESCRIPTION A/C ABOVE CEILING MINIMUM SIZE UTILITY TO FIXTURE FIXTURE # FIXTURE TYPE WASTE HOT WATER COLD WATER ABOVE FINISHED GRADE B/F CONNECTION SUPPLY SUPPLY P1H - - - WATER CLOSET- PUBLIC 4" --- 1/2" P2WH ��- LAVATORY - PUBLIC 1 1/4" 1/2" 1/2" P813 - -- - ELECTRIC WATER COOLER 1 1/4" --- 1/2" PLUMBING FIXTURE SCHEDULE FIXTURE SELECTION IS BASED ON KOHLER MODELS UNLESS OTHERWISE NOTED, APPROVED EQUAL MANUFACTURERS AS FOLLOWS: FIXTURES: ELDAY, JUST FAUCETS & TRIM: KOHLER, AMERICAN STANDARD, BRASSCRAFT, DELTA, MCGUIRE, SANITARY DASH, ZURN P1H WATER CLOSET - FLOOR MOUNTED - TANK - ELONGATED - SEAT W/COVER - PUBLIC: AMERICAN STANDARD 2216.143 - FLOOR MOUNT, TANK TYPE, COMBINATION FIXTURE, 1.5 GALLON FLUSH, VITREOUS CHINA, ELONGATED SIPHON JET, CHROME PLATED ACTUATOR, BOLT CAPS, WHITE. SEAT - BENEKE 520-HPSS COMMERCIAL GRADE SOLID PLASTIC, ELONGATED. CLOSED FRONT SEAT WITH COVER, STAINLESS STEEL POSTS AND SELF-SUSTAINING HINGES, WHITE. SUPPLY - BRASSCRAFT OCR1912 - 1/2" O.D. X 3/8" O.D. ANGLE STOP, WHEEL HANDLE, WALL FLANGE, CHROME PLATED. P2WH LAVATORY - WALL HUNG - GRID DRAIN: KOHLER K-2005 21" X 18" WALL HUNG LAVATORY, 4" CENTERS, CONCEALED ARMS, FRONT OVERFLOW AND BACKSLASH, WHITE. FAUCET.- KOHLER K-15199 SINGLE LEVER HANDLE, 4" CENTERS, FLOW RESTRICTOR, WITH GRID DRAIN REPLACEABLE CERAMIC DISC CARTRIDGE, AERATOR, 1 1/4" TAILPIECE, CHROME FINISH. SUPPLY - BRASSCRAFT SR1712A - 1/2" O.D. X 3/8" O.D. ANGLE SUPPLY, LOOSE KEY STOP, WALL FLANGE, CHROME PLATED. TRAP - MCGUIRE 8902 - 1 1/4" X 1 1/2", 17 GAUGE ADJUSTABLE TRAP WITH CLEANOUT AND WALL FLANGE, CHROME FINISH. DRAIN - MCGUIRE 155 -WC - 1 1/4", 17 GAUGE OFFSET DRAIN WITH OPEN GRID STRAINER, CHROME PLATED. LAVATORY WASTE TRAP PRIMER - JAY R. SMITH 2698 - 1 1/4", 17 GAUGE ADJUSTABLE WITH CLEANOUT AND WALL FLANGE, TRAP PRIMER TUBING WITH WALL FLANGE, CHROME PLATED. PROVIDE IN LIEU OF STANDARD TRAP AT LOCATIONS INDICATED ON DRAWINGS. INSULATION KIT - HANDI LAV -GUARD MODEL 102 AND 105 - SELF FASTENING, VINYL INSULATION COVERS FOR DRAIN, TRAPS, AND SUPPLY PIPING WITH ACCESSIBLE ANGLE VALVE INSULATION COVER, WHITE. CARRIER - SMITH 700 SERIES - ADJUSTABLE FLOOR SUPPORT WITH CONCEALED ARMS. P813 ELECTRIC WATER COOLER: OASIS P8ACSL WALL MOUNTED BARRIER FREE BI -LEVEL COOLERS, FRONT PUSHBUTTON OPERATION, HEAVY GAUGE STAINLESS STEEL, UNIT TO PROVIDE MINIMUM 8 GPH OF 50'F WATER WITH 90'F AMBIENT AND 80'F SUPPLY WATER TEMPERATURE, VINYL FINISH. SUPPLY - MCGUIRE ST07 - 1/2" O.D. X 3/8" O.D., WHEEL HANDLE STOP. TRAP - MCGUIRE 8902 - 1-1/4" X 1-1/2", 17 GAUGE ADJUSTABLE TRAP WITH CLEANOUT, CHROME FINISH. PLUMBING LEGEND SYMBOL ABBREVIATION DESCRIPTION A/C ABOVE CEILING A/F ABOVE FLOOR AFF ABOVE FINISHED FLOOR AFG ABOVE FINISHED GRADE B/F BELOW FLOOR B/G BELOW GRADE - - - CW COLD WATER PIPING C DN PIPING TURNING DOWN ��- GV GATE/BALL VALVE H.C. HANDICAPPED - -- - HW HOT WATER PIPING oc --- P -TRAP - S Sy SOIL, WASTE PIPING (ABOVE GROUND) - _S__ S,W SOIL, WASTE PIPING (BELOW GROUND) -+11-- --- UNION 0- UP PIPING TURNING UP V VENT PIPING VTR VENT THRU ROOF �- WCO WALL CLEANOUT 33// / \ WATER COOLER , 1/2" WH ; WC I � f C1/2"I I1/2" I 1/2" Tf \.� LAV .1 SANITARY AND DOMESTIC WATER ISOMETRICS SCALE: N.T.S. DRAINAGE PRODUCTS/SPECIALTIES UNLESS OTHERWISE INDICATED NUMBERS ARE JAY R. SMITH. EQUAL PRODUCTS: ZURN, JOSAM, WADE AND WATTS. CO -EXPOSED CLEANOUT - UNFINISHED AREAS JAY R. SMITH FIG. 4420 CAST BRONZE COUNTERSUNK PLUG WITH SLOT TO RECEIVE 1/2" THICK STEEL BAR STOCK. WCO-WALL CLEANOUT - FINISHED AREAS JAY R. SMITH FIG. 4436 C.I. FERRULE FOR NO HUB OR SERVICE WEIGHT PIPE, NICKEL BRONZE ROUND FRAME AND COVER WITH SECURING SCREWS. FCO -CONCRETE FLOORS JAY R. SMITH FIG. 4220 C.I. CLEANOUT WITH GASKET SEAL THREADED PLUG FOR EASY REMOVAL, ADJUSTABLE ROUND CAST IRON TOP WITH SECURING SCREW, SPEEDI-SET OUTLET CONNECTION. FCO -TILE FLOORS JAY R. SMITH FIG. 4151 C.I. CLEANOUT WITH GASKET SEAL THREADED PLUG FOR EASY REMOVAL, ADJUSTABLE ROUND NICKEL BRONZE TOP RECESSED FOR TILE WITH SECURING SCREW, SPEEDI-SET OUTLET CONNECTION. FCO -CARPETED FLOORS JAY R. SMITH FIG. 4020-Y C.I. CLEANOUT WITH GASKET SEAL THREADED PLUG, ADJUSTABLE ROUND NICKEL BRONZE TOP COMPLETE WITH STAINLESS STEEL CARPET MARKER WITH SECURING SCREW, SPEEDI-SET OUTLET CONNECTION. LAVATORY -WALL HUNG SUPPORT JAY R. SMITH #700 FOR MASONRY WALLS AND #700-M31 FOR METAL STUD WALLS. ELECTRIC WATER COOLER CARRIER -WALL HUNG JAY R. SMITH FIG. 830 SUPPORT WITH UPRIGHTS OF HIGH STRENGTH STEEL WITH WELDED BASES BOLTED TO FLOOR. FOR STEEL STUD WALLS, USE M31 RECTANGULAR UPRIGHTS. PLUMBING NOTES 1. REFER TO ARCHITECTURAL DRAWINGS FOR EXACT LOCATIONS AND ELEVATIONS OF ALL PLUMBING FIXTURES. 2. ALL PLUMBING WORK SHALL BE INSTALLED IN ACCORDANCE WITH THE 2001 INTERNATIONAL PLUMBING CODE WITH ALL APPLICABLE LOCAL CODE AND ORDINANCES. 3. ALL PIPING ABOVE GRADE SHALL BE PROPERLY SUPPORTED FROM THE BUILDING STRUCTURE AND SHALL NOT REST ON CEILING TILES OR BE SUPPORTED FROM CEILING TILES. 4. WATER PIPING ROUTED ABOVE CEILING AND IN EXTERIOR WALLS SHALL BE ROUTED ON HEATED SIDE (UNDERSIDE) OF CEILING INSULATION AND HEATED SIDE (INSIDE) OF WALL INSULATION. 5. SANITARY AND DRAINAGE PIPING 2" AND SMALLER SHALL BE SLOPED AT 1/4" PER FOOT MINIMUM, PIPING 3" AND LARGER SHALL BE SLOPED AT 1/8" PER FOOT MINIMUM. 6. LOCATE ALL SECTIONAL OR MAIN CONTROL VALVES WITHIN 1'-0" FROM ACCESS PANELS, CEILING TILES, OR OTHER POINT OF ACCESS. 7. ALL COLD WATER, AND DRAIN PIPING AT HANDICAPPED FIXTURES SHALL BE INSULATED WITH HANDI-LAV GUARD MODELS 102 AND 105 INSULATION KITS. 8. PROVIDE SHOCK ABSORBERS SIZED PER PDI SPECIFICATIONS ON ALL DOMESTIC WATER LINES SERVING PRV STATIONS AND OTHER INSTALLATIONS WITH QUICK CLOSING VALVES. 9. PROVIDE MANUFACTURED EXPANSION DEVICE OR FABRICATED EXPANSION LOOP ON ALL PIPING SYSTEMS CROSSING BUILDING EXPANSION JOINTS. 10. ALL PLUMBING EQUIPMENT, PIPING, INSULATION, ETC. INSTALLED IN HVAC PLENUM SPACES SHALL MEET CODE REQUIREMENTS FOR SMOKE AND COMBUSTIBILITY. 11. ALL PLUMBING EQUIPMENT AND SYSTEMS SHALL BE GUARANTEED FOR A MINIMUM PERIOD OF ONE YEAR AFTER FINAL ACCEPTANCE. 12. ALL PIPE PENETRATIONS OF FIRE AND/OR SMOKE RATED ASSEMBLIES SHALL BE FIRE STOPPED AS REQUIRED TO RESTORE ASSEMBLY TO ORIGINAL INTEGRITY. FIRE BARRIER PRODUCTS SHALL BE AS MANUFACTURED BY 3M COMPANY, CP25 CAULK, CS195 COMPOSITE PANEL, FS195 WRAP/SRINK, OR PSS 7900 SERIES SYSTEMS AS RECOMMENDED BY MANUFACTURER FOR PARTICULAR APPLICATIONS, OR EQUIVALENT SYSTEM AS APPROVED BY LOCAL CODE OFFICIALS. 13. ALL VENT THRU ROOF PENETRATIONS SHALL BE ROUTED TO TERMINATE AT THE LEAST VISIBLE LOCATION FROM THE ENTRY VIEW. PLUMBING MATERIALS 1. COLD AND HOT WATER PIPING ABOVE GRADE SHALL BE TYPE L HARD DRAWN COPPER TUBING CONFORMING TO ASTM B-88 WITH SWEAT JOINTS AND CAST OR WROUGHT FITTINGS. ALL JOINTS SHALL BE MADE WITH LEAD FREE SOLDER, DOMESTIC COLD WATER SERVICE PIPING BELOW GRADE SHALL BE CEMENT LINED DUCTILE IRON PIPE WITH PUSH -ON JOINTS. DOMESTIC WATER BRANCH PIPING BELOW GRADE SHALL BE PROTECTED WITH SLEEVES AT ALL PENETRATIONS THROUGH CONCRETE. 2. SANITARY WASTE & VENT PIPING ABOVE GROUND SHALL BE NO -HUB CAST-IRON WITH STAINLESS STEEL COUPLINGS, OR SCHEDULE 40 DWV PVC WITH SOLVENT JOINTS IF APPROVED BY LOCAL CODE OFFICIAL. PVC PIPING SHALL NOT BE LOCATED IN RETURN AIR PLENUM SPACES. 3. SANITARY WASTE PIPING BELOW GROUND SHALL BE CAST-IRON WITH PUSH -ON JOINTS, OR SCHEDULE 40 DWV PVC WITH SOLVENT JOINTS. 4. ALL ABOVE GRADE HOT AND COLD DOMESTIC WATER PIPING SHALL BE INSULATED EXCEPT AT HORIZONTAL CHASE BRANCH PIPING TO INDIVIDUAL PLUMBING FIXTURES AND ON VERTICAL RISERS WITHIN SEALED CHASES. ALL HOT WATER PIPING ABOVE GRADE SHALL BE INSULATED WITH 1 INCH NOMINAL THICKNESS PIPE INSULATION WITH VAPOR BARRIER JACKET, ALL COLD WATER PIPING ABOVE GRADE SHALL BE INSULATED WITH 1/2 INCH THICKNESS INSULATION ON PIPING 2" AND SMALLER, 1" THICK INSULATION ON PIPING 2 1/2" AND LARGER. OWENS-CORNING ASJ/SSLII OR EQUAL. CONNECT NEW 3/4"CW TO EXISTING 3/4" VALVED CW CONN. FIRE PROTECTION SYSTEM MATERIALS 1. ALL MATERIALS, PIPE, VALVES AND EQUIPMENT FURNISHED UNDER THIS SECTION SHALL BE NEW AND APPROVED BY NFPA, UNDERWRITER'S LABORATORIES, INC. (U.L.), FACTORY MUTUAL (FIN) AND AMERICAN WATER WORKS ASSOCIATION (AWWA) WHERE APPLICABLE, 2. SCHEDULE 40 WELDED OR SEAMLESS STEEL PIPE, ASTM A53, AND A135. A. CLASS 125, AND 250 CAST IRON THREADED FITTINGS, ANSI B16.4. B. CLASS 150, AND 300 MALLEABLE IRON THREADED FITTINGS, ANSI B16.3. C. GROOVED MECHANICAL COUPLINGS AND FITTINGS WITH EPDM GASKET, MALLEABLE IRON OIR DUCTILE IRON, 800 PSI MINIMUM RATING ASTM A47 AND A536, UAL. LISTED, F.M. APPROVED. 3. LIGHTWALL WELDED OR SEAMLESS STEEL PIPE, ASTM A53, AND A135. A. GROOVED MECHANICAL COUPLINGS AND FITTINGS WITH EPDM GASKET, MALLEABLE IRON OIR DUCTILE IRON, 800 PSI MINIMUM RATING ASTM A47, AND A5�36, U.L. LISTED, F.M. APPROVED. B. LIGHTWALL, 150 PSII, BUTTWELD FITTINGS, ANSI B16.9. 4. AUTOMATIC SPRINKLERS SHALL BE PROVIDED AS FOLLOWS: A. SMALL FRAME GLASS ELEMENT, SEMI -RECESSED, FAST RESPONSE PENDENT SPRINKLERS SHALL BE PROVIDED IN ALL AREAS WITH LAY -IN CEILINGS UNLESS OTHERWISE NOTED. TEMPERATURE RATING OF SPRINKLERS SHALL BE 155' - 165'. SPRINKLERS TO BE VIKING MICROFAST MODEL M SERIES WITH MODEL E-1 ESCUTCHEON, FINISH OF SPRINKLER AND ESCUTCHEON SHALL BE WHITE. B. FAST RESPONSE UPRIGHT PENDENT SPRINKLERS SHALL BE PROVIDED IN ALL AREAS WITH NO CEILING. TEMPERATURE RATING IS TO BE 165' UNLESS CONDITIONS REQUIRE HIGHER TEMPERATURE. FINISH OF SPRINKLER TO BE 'ROUGH BRASS. SPRINKLER TO BE VIKING MICROFAST MODEL M. C. ALTERNATE ACCEPTABLE MANUFACTURERS WITH EQUIVALENT SPRINKLERS ARE AUTOMATIC, CENTRAL, GRINNELL, GEM, AND RELIABLE. 5. ALL INTERIOR SPRINKLER PIPING SHALL MEET THE REQUIREMENTS OF APPLICABLE SECTIONS OF NFPA, AND THE: OWNER'S UNDERWRITER. ALL PIPE, FITTINGS, VALVES, AND SPRINKLER SYSTFEM COMPONENTS SHALL BE RATED FOR WORKING PRESSURES AS REQUIRED BY' SYSTEM DESIGN. 6. ALL PIPE, SUPPORTS AND HANGER ASSEMBLIES SHALL BE IN ACCORDANCE WITH NFPA-13 AND SHALL BE U.L.. LISTED OR F.M. APPROVED. 7. THE ADDITION TO THE EXISTING SPRINKLER SYSTEMS SHALL BE DESIGNED TO THE EXISTING AVAILABLE WATER SUPPLY PREESSURE. THE CONTRACTOR SHALL CONFIRM THE REVISED SPRINKLER PIPING ARRANGEMENT WITH HYDRAULIC CALCULATIONS. 8. THE TENANT BUILD -OUT AREAL IS TO BE PROVIDED WITH AUTOMATIC SPRINKLERS BASED UPON LIGHT HAZARD DESIGN CLASSIFICATION WITH A DENSITY OF .10 GPM OVER 1500 SQ. FT. AND MAXIMUM OF 2215 SQUARE FEET SPACING. 9. SPRINKLER HEADS INSTALLED IN LAY IN ACOUSTICAL TILE CEILINGS SHALL BE CENTERED IN THE CEILING TILES OR INSTAL! .LED ON QUARTER POINTS OF THE FOUR FOOT DIMENSIONS OF 2' X 4' TILES. 10, ALL FIRE PROTECTION EQUIPMENT AND SYSTEMS SHALL BE GUARANTEED FOR A PERIOD OF ONE YEAR AFTER FINAL ACCEPTANCE. 11, ALL PIPING ABOVE GRADE SHALL BE SUPPORTED BY THE BUILDING STRUCTURE AND SHALL NOT REST ON CEILING TILES OR CEILING STRUCTURE. PIPING HUNG FROM JOISTS SHALL BE HUNG FROW THE TOP CHORDS OF THE JOISTS. 12. ALL SPRINKLER PIPING SHALL. BE ROUTED TO MAINTAIN DESIGNED CEILING HEIGHTS INDICATED ON ARCHITECTURAL. DRAWINGS. 13. ALL FIRE PROTECTION DRAWINIGS SUBMITTALS SHALL BE AT 1/8" SCALE AS A MINIMUM. ALL SUBMITTALS SHALL BE INI REPRODUCIBLE VELLUM OR MYLAR FORMAT ONLY SUBMITTALS OF MULTIPLE PRIINTS WILL BE RETURNED WITHOUT REVIEW. 14. FIRE PROTECTION SHOP DRAWINGS SHALL INCLUDE ALL DATA REQUIRED BY N.F.P.A. SECTION 13. SHOP DRAWING PLANS SHALL INDICATE ALL LIGHTS, GRILLES, SOFFITS, ALARMS, SPEAKERS AND OTHER CEILING COMPONENTS, AS WELL AS HYDRAULIC NODE POINTS, TO INSURE COORDINATION. THE CONTRACTOR SHALL SUBMIT SHOP DRAWINGS TO AND SECURE APPROVAL OF THE OWNER'S UNDERWRITER, LOCAL AUTHORITY AND/OR STATE AUTHORITIES PRIOR TO SUBMISSION TO THE ENGINEER. THE CONTRACTOR SHALL NOT COMMENCE WORK, PURCHASE, OR PROVIDE ANY MATERIALS TO THE JOB SITE WITHOUT OBTAINING SHOP DRAWING APPROVAL FROM THE ABOVE AND THE ENGINEER. SHOP DRAWINGS SHALL INCLUDE COPIES OF ALL HYDRAULIC CALCULATIONS PROVIDING DESIGN DENSITIES, WHERE APPLICABLE. 15. ALL DESIGN DRAWINGS AND CALCULATIONS PREPARED BY THE FIRE PROTECTION SUBCONTRACTOR SHALL BEAR THE SEAL OF A REGISTERED PROFESSIONAL ENGINEER LICENSED IN THE STATE OF GEORGIA OR EQUIVALENT FIRE SPRINKLER CONTRACTOR'S CERTIFICATE SEAL. REVISION # 38 SUMMARY A. ADDED SHEET PHILLIPS MONN-on P A R T N E R S H I P Architecture - Interior Design • Planning 770.3941616 `ax 770.3941314 CONSULTANT SEAL OO 0 Jordan & Skala Engineers, Inc, Project Number - 0410070 5365 OAKBROOK PARKWAY, NORCROSS, GA 30093 PHONE (770)447-5547 FAX (770)448-0262 E L. jse®jordanskala.com COPYRIGHT © 2004 JORDAN & SKALA ENGINEERS INC. REVISIONS # DATE DESCRIPTION 10/18/04 SHOPS WHITE BOX This document is © Phillips Partnership, PC and is considered an Instrument of Service and is solely for use with respect to the project as indicated below. All rights reserved. This document may not be reproduced without the prior written consent of Phillips Partnership, PC. TENANT STANDARD WHITE BOX SHOP 1081 W.P. BALL BOULEVARD PROJECT THE MARKETPLACE AT SEMINOLE TOWNE CENTER 0 SANFORD, FLORIDA ELECTRICAL SPECIFICATIONS TYPE DESCRIPTION I. SCOPE LA1 A 2' X 4', 4 -LAMP RECESSED ACRYLIC LENS MAINS: 225A MLO 4. ALL BRANCH CIRCUIT CONDUCTORS SHALL BE CONNECTED AS INDICATED I PHASE: 3 INSTALL ALL ELECTRICAL WORK COVERED BY THE BELOW SPECIFICATIONS AND MOUNTING: SURFACE ON THE DRAWINGS. COMMON NEUTRALS AND GROUND WIRES MAY BE NOTES: . APPROVED DRAWINGS. PROVIDE ALL MATERIAL, LABOR, TRANSPORTATION, TOOLS, CKT TRIP # POLE PULLED IN CONDUITS WHERE ONLY OPPOSITE PHASE CONDUCTORS ARE LTG SUPERVISION, ETC., NECESSARY TO COMPLETE THE TOTAL ELECTRICAL JOB. ALL PHASE A B C RUN. ALL CONDUITS SHALL HAVE A GROUND WIRE PULLED AND SHALL DESCRIPTION TRIP,,-'CKT POLE ITEMS NOT SPECIFICALLY MENTIONED HEREIN WHICH ARE OBVIOUSLY NECESSARY( TO 1 20/1 COMPLY WITH ARTICLE #250 OF THE NATIONAL ELECTRICAL CODE. BKBD MAKE A COMPLETE WORKING INSTALLATION SHALL BE PROVIDED BY THE CONTRACTOR, -- q................. Q.._...._..... ��'����� ����� ��� t r........ ...... ....... ... T € :.....,........ __ 0.05 1.1 INCLUDING ANY NECESSARY FIELD ENGINEERING AND/OR DETAIL DRAWINGS REQUIRED. 5. ALL FEEDER AND BRANCH CIRCUIT CONDUCTORS NO. 6 AWG AND LARGER 1.05 LIGHTS 20/1 DRAWINGS SHALL BE SUBMITTED FOR APPROVAL AS PROVIDED FOR IN "SHOP 5 20/1 RECEPTS. 0.8 SHALL BE PHASE IDENTIFIED IN EACH ACCESSIBLE ENCLOSURE BY ONE 6 DRAWINGS". 1.5 WATER HEATER EWH-1 20/1 INCH WIDE PLASTIC TAPE ATTACHED TO CONDUCTORS IN A READILY 9 20/1 RECEPT-SHOW WINDOW 0.6} SPACE lo- VISIBLE LOCATION. TAPE COLORS SHALL MATCH COLOR CODE II. CODES AND FEES 13 SPACE REQUIREMENTS SPECIFIED HEREIN. 14 ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE REQUIREMENTS OF THE LATEST 6. CONNECTIONS BETWEEN FIXTURE JUNCTION BOX AND FIXTURE SHALL BE 17 SPACE EDITION OF THE NATIONAL ELECTRICAL CODE, N.F.P.A. #70, NATIONAL ELECTRICAL 18 MADE WITH NO 16. AWG SILICONE RUBBER INSULATED STRANDED SPACE SAFETY CODE, ANSIC-2 AND ALL LOCAL AND STATE CODES AND REGULATIONS. THE 21 SPACE FIXTURE WIRE, TYPE SFF - 2 (150?C.) OR NO. 16 AWG 22 CONTRACTOR SHALL OBTAIN AND PAY FOR ALL PERMITS AND INSPECTIONS REQUIRED SPACE THERMOPLASTIC, NYLON JACKETED STRANDED FIXTURE WIRE, TYPE THHN 25 SPACE BY THE BUILDING AND SAFETY CODES AND ORDINANCES, AND THE RULES AND 26 (90°C.) COLOR CODE AS SPECIFIED HEREIN SHALL NOT BE REQUIRED SPACE REGULATIONS OF ANY LEGAL BODY HAVING JURISDICTION. 29 SPACE FOR FIXTURE WIRE; HOWEVER, NEUTRAL AND GROUND CONDUCTOR SHALL 30 31 SPACE SPACE BE IDENTIFIED DISTINCTLY FROM PHASE CONDUCTORS AS PER THE III. WORKMANSHIP 34 ABOVE SPECIFICATIONS. SPACE ALL WORK SHALL BE NEATLY, ORDERLY AND SECURELY INSTALLED WITH CONDUITS, 7. SPLICES IN CONDUCTORS SHALL BE MADE ONLY WITHIN JUNCTION 38 PANELS, BOXES, SWITCHES, ETC., PERPENDICULAR AND/OR PARALLEL WITH THE SPACE BOXES, WIRING TROUGHS, AND OTHER ENCLOSURES AS PERMITTED BY 41 -- ---- 0.6 5.3 PRINCIPAL STRUCTURAL MEMBERS, AND SHALL BE LEFT IN PROPER WORKING ORDER. 42 THE NATIONAL ELECTRICAL CODE. DO NOT SPLICE CONDUCTORS IN 91'4" AFF, THE DRAWINGS ARE DIAGRAMMATIC AND INDICATE THE GENERAL ARRANGEMENT OF 2.7 0.0 PANELBOARDS, SAFETY SWITCHES, OR MOTOR CONTROL ENCLOSURES. ELECTRICAL EQUIPMENT. COORDINATE DEVICE LOCATIONS WITH DOOR SWINGS, TOTAL CONNECTED LOAD: 25.5 SPLICES IN CONDUCTORS NO. 10 AWG OR SMALLER SHALL BE MADE WITH RECEPTACLES: CABINETS, COUNTERS, ETC., AS INDICATED ON THE ARCHITECTURAL DRAWINGS. DO CONNECTED SKOTCHLOK INSULATED SPRING CONNECTORS, IDEAL WRAPPING NOT SCALE ELECTRICAL PLANS. OBTAIN DIMENSIONS FOR LAYOUT OF EQUIPMENT INSULATED CAPS. SPLICES IN CONDUCTORS NO. 8 AWG AND LARGER 1.9 FROM ARCHITECTURAL PLANS UNLESS INDICATED ON ELECTRICAL PLANS. 10.2 SHALL BE MADE WITH SPLIT BOLT CONNECTORS TAPED WITH NO. 88 PLASTIC ELECTRICAL TAPE UNLESS SPLICES ARE SPECIFICALLY IV. SUBSTITUTIONS INDICATED TO BE MADE WITH CRIMPING SLEEVE APPLIED TO PHASE B 8.1 67.9 CONDUCTORS WITH HYDRAULICALLY OPERATED CRIMPING TOOL. ALL COST INCURRED BY THE ACCEPTANCE OF SUBSTITUTIONS SHALL BE BORNE BY THE HEATING: CONTRACTOR. PROOF FOR THE EQUALITY OF SUBSTITUTIONS SHALL BE BY THE D. JUNCTION BOXES 7.2 CONTRACTOR. DEMAND LOAD (AMPERES): 70.8 ALL JUNCTION BOXES SHALL BE CONSTRUCTED OF CODE GAUGE GALVANIZED V. U.L. APPROVAL SHEET STEEL AND COMPLY WITH ARTICLE #314 OF THE NATIONAL ELECTRICAL KVA AMPS CODE, FOR THE NUMBER, SIZE AND POSITION OF CONDUITS ENTERING THE ALL ELECTRICAL ITEMS COVERED BY THIS SPECIFICATION SHALL BE U.L. LABELED BOX, SIZE OF BOX AND MAXIMUM NUMBER OF CONDUCTORS IN A BOX. 0.0 AND LISTED FOR THEIR SPECIFIC USE. MIN. PANEL AMPACITY: 72.7 E. PANELBOARDS VI. ELECTRICAL SERVICE 1. SHALL BE SPECIFIED ON THE DRAWINGS. A. ELECTRICAL SERVICE SHALL BE AS INDICATED ON THE DRAWINGS. SERVICE SHALL ORIGINATE AS SHOWN ON THE DRAWINGS. 2. SHALL BE BOLT -IN CIRCUIT BREAKER TYPE WITH A 100% RATED MAIN BREAKER OR RATED MAIN LUGS ONLY AS NOTED ON DRAWINGS. ALL B. SERVICE CONNECTIONS AT SERVICE POINT SHALL BE MADE BY THE LOCAL SHALL HAVE U.L. APPROVED INTERRUPTING CAPACITY OF 22,000 AMPS UTILITY COMPANY. THE ELECTRICAL CONTRACTOR SHALL PAY ALL COST MINIMUM UNLESS INDICATED ON DRAWINGS RMS SYM. AT VOLTAGE REQUIRED BY THE_LOCAL UTILITY COMPANY PROVIDING SERVICES INDICATED.. INDICATED ON DRAWINGS. ALL BUSSING SHALL BE COPPER. ELECTRICAL CONTRACTOR SHALL COORDINATE METERING, TRANSFORMER PAD, CONNECTION POINTS AND GROUNDING WITH UTILITY COMPANY. 3. SIDE AND GUTTERS SHALL HAVE MINIMUM CODE CLEARANCES. DEPTH SHALL BE 5 3/4" MINIMUM. C. THE MAIN DISCONNECT AND PANEL SHALL BE LABELED FOR SERVICE ENTRANCE EQUIPMENT. 4. APPROVED MANUFACTURERS ARE: SQUARE D, CUTLER -HAMMER, SIEMENS, AND GENERAL ELECTRIC. VII. TEST 5. TYPEWRITTEN DIRECTORIES AND PANELBOARD DESIGNATION PLATES A. UPON COMPLETION OF THE WORK, A TEST OF THE INDIVIDUAL SYSTEMS SHALL BE PROVIDED BY THE CONTRACTOR FOR ALL PANELBOARDS. INCLUDING ALL FEEDERS, BRANCHES, OUTLETS, LIGHTING, MOTORS APPARATUS AND APPLIANCES, TO ASSURE OPERATION IN COMPLIANCE WITH THESE F. LIGHTING FIXTURES SPECIFICATIONS AND THE DRAWINGS. A LETTER WITH ALL PERTINENT TEST DATA SHALL BE SUBMITTED TO THE ARCHITECT AT LEAST (5) FIVE DAYS 1. UNLESS INDICATED ON DRAWINGS, BALLASTS PROVIDED WITH FIXTURES PRIOR TO COMPLETION OF PROJECT. SHALL BE ETL-CBM APPROVED, HIGH POWER FACTOR, WITH U.L. LABEL. ALL BALLASTS FOR RAPID START LAMPS SHALL BE PREMIUM CLASS P. B. CONTRACTOR SHALL PROVIDE ALL INSTRUMENTS, LABOR AND MATERIALS FOR BALLASTS SHALL BE FOR THE VOLTAGE OF THE CIRCUIT TO WHICH ANY ESSENTIAL INTERMEDIATE AND FINAL TESTS TO PROVIDE COMPLIANCE CONNECTED. BALLASTS SHALL BE PROVIDED FOR ALL FLUORESCENT AND WITH THESE SPECIFICATIONS. HIGH INTENSITY DISCHARGE LAMPS. EACH BALLAST SHALL BE PROTECTED BY AN INTERNAL FAST BLOWING FUSE. CONTRACTOR TO VIII. GUARANTEE PROVIDE PROPER FUSES. WORK SHALL BE GUARANTEED FOR A ONE (1) YEAR PERIOD. 2. LAMPS SHALL BE PROVIDED FOR ALL FIXTURES IN ACCORDANCE WITH FIXTURE SCHEDULE. IX. SPECIFICATIONS G. WIRING DEVICES A. GROUNDING 1. RECEPTACLES AND WALL SWITCHES SHALL BE OF THE TYPE AND SIZE 1. SHALL COMPLY WITH ARTICLE #250 OF THE NATIONAL ELECTRICAL CODE INDICATED BY HUBBELL, P&S, OR ARROW HART MAY BE USED. AND ALL STATE AND LOCAL CODES AND REQUIREMENTS OF THE UTILITY COMPANY PROVIDING SERVICE AND SHALL BE PROVIDED AS PER THESE a. ALL SWITCHES SHALL BE 20 AMP 120 VOLT SPECIFICATION SPECIFICATIONS AND THE DRAWINGS. GRADE WITH IVORY HANDLES UNLESS OTHERWISE NOTED. NUMBER OF POLES SHALL BE AS INDICATED ON DRAWINGS. 2. THE BUILDING ELECTRICAL SYSTEMS SHALL BE SOLIDLY GROUNDED SUPPLEMENTED WITH EQUIPMENT CONDUCTORS. ALL NON-CURRENT b. DUPLEX OUTLETS SHALL BE 20 AMP 125 VOLT A.C. 3 -WIRE CARRYING PARTS OF THE ELECTRICAL SYSTEM, I.E., RACEWAYS, SPECIFICATION GRADE STRAIGHT BLADE WITH IVORY FACE, EQUIPMENT ENCLOSURES, FRAMES, JUNCTION AND OUTLET BOXES AND UNLESS OTHERWISE NOTED ON DRAWINGS. OTHER CONDUCTIVE ITEMS IN CLOSE PROXIMITY WITH ELECTRICAL CIRCUITS, SHALL BE GROUNDED TO PROVIDE A LOW IMPEDANCE PATH 2. DEVICE PLATES SHALL BE IVORY COLORED AND SHALL BE PLASTIC FOR POTENTIAL GROUND FAULTS. (UNLESS OTHERWISE NOTED ON DRAWINGS). 3. BRANCH CIRCUIT EQUIPMENT GROUNDING CONDUCTORS ARE NOT SHOWN ON 3. TIME CLOCK SHALL BE PARAGON EL72 OR EQUAL. THE DRAWINGS, HOWEVER, AN EQUIPMENT GROUNDING CONDUCTOR SHALL BE INSTALLED IN ALL RACEWAYS AND CABLES. H. DISCONNECT SWITCHES B. RACEWAYS 1. DISCONNECT SWITCHES SHALL BE A MINIMUM OF 30 AMP, 250 VOLT RATED, HEAVY DUTY TYPE, 3 POLE WITH SOLID NEUTRAL, UNLESS 1.-- ALL -RACEWAYS (UNLESS NOTED HEREIN) SHALL BE ELECTRICAL- OTHERWISE NOTED. METALLIC TUBING (EMT) AND SHALL BE FERROUS GALVANIZED CONIDUIT AND SHALL COMPLY WITH ARTICLE #358 OF THE NATIONAL ELECTRICAL CODE OR BE INTERMEDIATE METAL CONDUIT (IMC) AND SHALL BE FERROUS GALVANIZED CONDUIT AND SHALL COMPLY WITH ARTICLE #342 OF THE NATIONAL ELECTRICAL CODE OR BE RIGID STEEL CONDUIT AND SHALL COMPLY WITH ARTICLE #344 OF THE NATIONAL ELECTRICAL CODE. EMT COUPLINGS SHALL BE STEEL SET SCREW TYPE. 2. FLEXIBLE METAL CONDUIT SHALL BE USED FROM JUNCTION BOXES TO CORRESPONDING RECESSED LIGHTING FIXTURES AND SHALL COMPLY WITH ARTICLE #348 OF THE NATIONAL ELECTRICAL CODE. 3. LIQUID TIGHT FLEXIBLE METAL OR NON-METALLIC CONDUIT SHALL BE USED FROM OUTDOOR EXPOSED CONNECTIONS TO GROUND OR ROOF MOUNTED EQUIPMENT AND COMPLY WITH ARTICLE #350 OF THE NATIONAL ELECTRICAL CODE. 4. RIGID NONMETALLIC CONDUIT SHALL BE PVC SCHEDULE 40 AND SHALL COMPLY WITH ARTICLE #352 OF THE NATIONAL ELECTRICAL CODE. RIGID NON-METALLIC CONDUIT MAY BE USED FOR SERVICE ENTRANCE, IF ALLOWED BY LOCAL CODE AUTHORITY AND INSTALLED PER THE NATIONAL ELECTRICAL CODE. 5. ALL RACEWAYS SHALL BE INSTALLED CONCEALED EXCEPT IN UNFINISHED SPACES OR WHERE INDICATED. C. CONDUCTORS 1. ALL CONDUCTORS SHALL BE COPPER AND HAVE 600 VOLT TYPE, 90°C, THHN/THWN INSULATION EXCEPT WHERE NOTED ON THE DRAWINGS. 2. ALL BRANCH CIRCUITS SHALL BE MINIMUM OF #12 AWG SOLID COPPER EXCEPT FOR MOTOR LEADS, WHICH SHALL BE A MINIMUM OF #12 AWG STRANDED COPPER, UNLESS OTHERWISE NOTED ON DRAWINGS. 3. ALL BRANCH CIRCUIT AND FEEDER CONDUCTORS, NO. 8 AWG AND SMALLER, SHALL BE COLOR CODED AS FOLLOWS: 120/208 VOLT SYSTEM PHASE A - BLACK PHASE B - RED PHASE C - BLUE NEUTRAL - WHITE GROUND - GREEN O PROVIDE LOCK -ON DEVICE LIGHTING FIXTURE SCHEDULE TYPE DESCRIPTION PANELBOARD SCHEDULE - LA1 A 2' X 4', 4 -LAMP RECESSED ACRYLIC LENS MAINS: 225A MLO VOLTAGE: 208/120 120V. I PHASE: 3 1 WIRE:4 MOUNTING: SURFACE AIC: 10,000 NOTES: . 2#12,1#12G -1/2"C. CKT TRIP # POLE DESCRIPTION LTG LOAD(KVA) RCPT •MTR A/C HTG KIT MISC PHASE A B C LOAD(KVA) MISC KIT- HTG A/C MTR RCP LTG DESCRIPTION TRIP,,-'CKT POLE # 1 20/1 RECEPT-TELEP. BKBD 1.0- -- q................. Q.._...._..... ��'����� ����� ��� t r........ ...... ....... ... T € :.....,........ __ 0.05 1.1 LIGHTS 20/1 2 3 20/1 RECEPTS. 0.6 1.05 LIGHTS 20/1 4 5 20/1 RECEPTS. 0.8 0.5 NIGHT EMERGEINCY LIGHTS 20/1 6 7 20/1 RECEPTS. 0.6 1.5 WATER HEATER EWH-1 20/1 8 9 20/1 RECEPT-SHOW WINDOW 0.6} SPACE lo- ll SPACE- SPACE 12 13 SPACE SPACE 14 15I • SPACE SPACE • 16 17 SPACE SPACE 18 19 SPACE SPACE 20 21 SPACE SPACE 22 23 SPACE SPACE 24 25 SPACE SPACE 26 27 SPACE SPACE 28 29 SPACE SPACE 30 31 SPACE SPACE 32 33 SPACE SPACE 34 35 SPACE SPACE 36 37 70/3 RTU -4 0.6 5.3 SPACE 38 39 -- ---- 0.6 5.3 SPACE 40 41 -- ---- 0.6 5.3 SPACE 42 LIGHTING: 91'4" AFF, 2.7 0.0 3.6 11.8 10.0 115.9 10.0 0.0 0.0 0.0 1.5 0.0 10.1 0.0 2.7 TOTAL CONNECTED LOAD: 25.5 RECEPTACLES: 3,6 CONNECTED LOAD (KVA) CONNECTED LOAD (KVA) TOTAL DEMAND LOAD: 25.5 MOTORS: 1.9 PHASE A 10.2 84.6 A/C: 0,0 PHASE B 8.1 67.9 CONNECTED LOAD (AMPERES): 70.8 HEATING: 17.4 PHASE C 7.2 60.0 DEMAND LOAD (AMPERES): 70.8 KITCHEN: 0.0 KVA AMPS MISCELLANEOUS: 0.0 MIN. PANEL AMPACITY: 72.7 O PROVIDE LOCK -ON DEVICE LIGHTING FIXTURE SCHEDULE TYPE DESCRIPTION MANUFACTURER CATALOG NO. LAMPS NOTES A 2' X 4', 4 -LAMP RECESSED ACRYLIC LENS LIGHTOLIER XP2GVA43212004 OR EQUAL BY 4-F32T8/SP35 120V. INCLUDED W/UNIT TROFFER, WITH ELECTRONIC BALLAST, GRID METALUX 120V/10 LA1-8 2#12,1#12G -1/2"C. TYPE. COLUMBIA EF -1 120V/10 CKT. W/LTS. 2#12,1#12G -1/2"C. DAYBRITE IN CEILING LITHONIA B 2', 2 -LAMP WALL MTD FIXTURE WITH LIGHTOLIER LSW2217-120-SO OR EQUAL BY 2417T8/SP35 120V. STANDARD WHITE ACRYLIC LENS, ELECTRONIC BALLAST. MEALUX PROJECT THE MARKETPLACE AT SEMINOLE TOWNE CENTER 0 COLUMBIA CLIENT NORTH AMERICAN PROPERTIES NORTH AMERICAN PROPERTIES -ATLANTA 1080 HOLCOMB BRIDGE ROAD BUILDING 200, SUITE 150 ROSWELL, GA 30075 TEL (770) 645-6566 FAX (770) 643-9540 PHILLIPS JOB NUMBER DAYBRITE 05/14/04 DRAWN BY/CHECKED BY AVVO/CCJ DRAWING TITLE WHITE BOX FLOOR PLAN - LITHONIA SHEET NUMBER El ■ 6 VOLT TWIN -HEAD BATTERY LIGHT, EMERGILITE PRO -2 INCLUDED 120V. E SURFACE MOUNTED. SURELITES CC -2 PRESCOLITE EDS -2 CHLORIDE GM1 LITHONIA ELM2 COMBINATION EXIT/EMERGENCY, LIGHTOLIER LLC2URW-PENDANT OR EQUAL BY L.E.D. 120V., PENDANT MOUNTED XA POLYCARBONATE, RED LETTERS SURELITES WITH CENTER OF FIXTURE PRESCOLITE 91'4" AFF, CHLORIDE LITHONIA MECHANICAL EQUIPMENT CONNECTION SCHEDULE DESCRIPTION VOLTAGE CIRCUIT CONDUCTORS DISCONNECT NOTES RTU -4 208V/30 LA1-37 3#4,1 #8G-1 "C. INCLUDED W/UNIT ON ROOF EWH-1 - 120V/10 LA1-8 2#12,1#12G -1/2"C. 30/2/1 ABOVE CEILING EF -1 120V/10 CKT. W/LTS. 2#12,1#12G -1/2"C. INCLUDED W/UNIT IN CEILING This document is © Phillips Partnership, PC and is considered an Instrument of Service and is solely for use with respect to the project as indicated below. All rights reserved. This document may not be reproduced without the prior written consent of Phillips Partnership, PC, TENANT STANDARD WHITE 0❑ WHITE BOX FLOOR PLAN SCALE: 1/8" = V-0" KEY NOTES: SUITE 1081 - ELECTRICAL 10 24" X 24" X 3/4" PAINTED PLYWOOD TELEPHONE BACKDOARD. EXTEND 1" EMPTY CONDUIT TO LANDLORD'S TELEPHONE CABINET. O2 JUNCTION BOX MOUNTED AT STOREFRONT FOR TENANT SI(GN POWER. COORDINATE EXACT JUNCTION BOX LOCATION AND MOUNTING HEIGHT WITH ARCHITECT'S ELEVATION PRIOR TO ROUGH -IN. EXTEND 3/4" EMPTY CONDUIT WITH PULL WIRE TO TENANT PANEL AND TERMINATE. �3 DUPLEX RECEPTACLE MOUNTED FLUSH IN CEILING TILE AB30VE SHOW WINDOW. ROOF MOUNTED GFI RECEPTACLE PROVIDED WITH ROOF TOP MECHANICAL UNIT. ELECTRICAL CONTRACTOR SHALL EXTEND TO CIRCUIT NOTED IN TENANT PANEL. �5 NUMBER ADJACENT TO DEVICE OR FIXTURE DENOTES CIRCUIT BREAKER DEVICE OR FIXTURE IS SERVED FROM IN TENANT PANEL. O FIXTURE NOTED WITH "NL" SHALL BE A NIGHTLIGHT THAT OPERATES 24 HRS., CIRCUIT WITH EMERGENCY LIGHTS AS SHOWN. O LANDLORD'S FIRE ALARM CONTROL PANEL. PROVIDE POWER FROM NEW 20A/1 P CIRCUIT BREAKER IN LANDLORD'S HOUSE PANEL HPA. PROVIDE 277V/120V STEP DOWN TRANSFORMER WITH IN-LINE FUSING ON PRIMARY /AND SECONDARY FEEDERS, FEEDERS SHALL BE 2#12,1#12G -1/2"C., LOCATE TRANSFORMER ABOVE FACP. PROVIDE LOCK -ON DEVICE ON FEEDER BREAKER WITHIN PANEL HPA. REVISION # 34 SUMMARY A. ADDED SHEET PHILLIPS P A R T N E R S H I P Architecture • Interior Design • Planning 770.3941616 `ax 770.3941314 RF RE K J I L B E F G H C A B C D ANCHOR CONSULTANT ,71 Jordan & Skala Engineers, Inc. 73 Project Ntsnber • 0410070 �1 5365 OAKBROOK PARKWAY, NORCROSS, G4 30093 PHONE (770)447-5547 FAX (770)448-0262 171 E L• jse®jordanskala.com COPYRIGHT © 2004 JORDAN k SKALA ENGINEERS INC. SEAL REVISIONS # DATE DESCRIPTION 10/18/04 SHOPS WHITE BOX This document is © Phillips Partnership, PC and is considered an Instrument of Service and is solely for use with respect to the project as indicated below. All rights reserved. This document may not be reproduced without the prior written consent of Phillips Partnership, PC, TENANT STANDARD WHITE BOX SHOP 1081 W.P. BALL BOULEVARD PROJECT THE MARKETPLACE AT SEMINOLE TOWNE CENTER 0 SANFORD, FLORIDA CLIENT NORTH AMERICAN PROPERTIES NORTH AMERICAN PROPERTIES -ATLANTA 1080 HOLCOMB BRIDGE ROAD BUILDING 200, SUITE 150 ROSWELL, GA 30075 TEL (770) 645-6566 FAX (770) 643-9540 PHILLIPS JOB NUMBER 0208616 ISSUE DATE 05/14/04 DRAWN BY/CHECKED BY AVVO/CCJ DRAWING TITLE WHITE BOX FLOOR PLAN - ELECTRICAL SHEET NUMBER El ■