Loading...
1081 WP Ball Blvd - BC06-000697 (ALTERNATIVE CLINIC) (TENANT BUILDOUT) (A)PERMIT ADDRESS CONTRACTOR ADDRESS C` Jam. PHONE NUMBER P 1 PROPERTY OWNER �� 4 � 5- �21 10, c > v � ADDRESS North American Properties LLC 1080 Holcomb Bridge Bldg 200 Ste. 150 _ Roswell, GA 30076 PHONE NUMBER_ 770-325-4912 ELECTRICAL CONTRACTOR MECHANICAL CONTRACTO PLUMBING CONTRACTOR MISCELLANEOUS CONTRACTOR PERMIT NUMBER FEE MISCELLANEOUS CONTRACTOR PERMIT NUMBER FEE SUBDIVISION PERMIT #C, p � DATE � PERMIT DESCRIPTION PERMIT VALUATION --C� SQUARE FOOTAGE <�vC t d A�L��ICJ � �c 'ko_ �I A � � I� IILII[,IIC �]IL'71[' I� I]E�' l �'� I��% I� �' IIL�I l �I c9 _,P0A6 y A" r 1081 We P. BAL r 0 u r L SUITE 1081 INDEX OF DRAWINGS ID -0.0 INDEX & COVER SHEET ID -1.0 FLOOR PLAN—DETAILS—SCHEDULES ID -2.0 REFLECTED, CEILING PLAN—ELEVATIONS El LIGHTING FLOOR PLAN—FIXTURE SHEDULE—SPECIFICATIONS E2 POWER FLOOR PLAN—PANEL SCHEDULE—RISER DIAGRAM M1 HVAC FLOOR PLAN—LEGEND M2 HVAC SPECIFICATIONS— SHEDULES—DETAILS Pi PLUMBIlNG FLOOR PLAN & SPECS BUILDING CODE ANALYSIS SUMMARY SPRINKLERED = YES OCCUPANCY CLASS = GROUP B BUILDING HEIGHT = SINGLE STORY CONDITIONED SPACE = +/-1,500 S.F. UNCONDITIONED SPACE = 0 S.F. ESTIMATED CONSTRUCTION COST = $50,000 CONSTRUCTION TYPE = TYPE V CODES USED: FLORIDA BUILDING CODE, 2001 EDITION FLORIDA ACCESSIBILITY CODE, 2001 EDITION FLORIDA FIRE PREVENTION CODE, 2001 EDITION CITY OF ORLANDO, 2004 EDITION LIFE SAFETY SYSTEM EMERGENCY LIGHTING EXIT SIGNS FIRE ALARM SYSTEM EXIT REQUIREMENTS DEAD END LIMITS 20' MAX. TRAVEL TO EXITS 300' EXIT REQUIRED = 1 EXIT PROVIDED = 1 REVIEW. v. Sanford Fire Prev DIV. Date:, h � t DRAWN BY DAVID R. BROWN CHECKED DRB DATE SCALE AS NOTED JOB NO. SHEET u U - G[i / P-6 ALL W STORAGE I TOILET � I 0 — 4")Q CAVITY FOR DRYER HAND WASH SINK W/ VENTILATION--,_W/D ( TO ROOF) 411 STACK STORAGE ABOVE & BELOW 0 � � o EXIST. ROOF DECKING STIFFEN T( BAR JOIST REQUIRED 5HOE BINS / STORAGE r r ----I r---� r---� r ----I r---------- I I I I I I I I I I -� 3' I I 3 I W I I w I I w oWz 3 oZ 3 oZ w�Lu �� °� U- I L--------- o � I I JJ I I Lu I I Lu C3 I r----------� rt I I I g I PT AREA -UNKNOWN SPACE FL REQ. PER PERSON (MATWORK, EXERCISE DALL,I STRETCHING, EVAL.) --------- L --J J 3 - ID -1.0 PILATES AND PT ARP-1-1 ALL WALLS EAS SEPARATE FROM RECEPTION AND HALLWAY. q ------ ID -1.0 LOW WALL W/ LUMICOR PANEL ABOVE L- - - - - - - - - - p> P-1 ALL WALLS — — — — — �- 1 ID -2.0 3 = co 5 P- ALL W TREATMENT ROOM #3 TREATMENT ROOM #2 P-4 ALL WALLS P-3 ALL WALLS c� c� 9' 9' 2 04 � FL(�®R PLAN TREATMENT ROOM #1 rP-2 ALL WALLS c� EXIST. ROOF DECKING — STIFFEN TO BAR JOIST -OP OF REQUIRED ACOUSTICAL ;EILING 1 /2"GYP. BD. 1 /2"GYP. BD ON 3 5'8" ON 3 5'8" METAL STUD METAL STUD MID -WALL MID -WALL BRACING BRACING NON—RATED PARTITION QJ ­SCALE: 1 /2" = V-0" SOUND ATTENUATIC BLANKET 2 ID -2.0 v ID -2.0 — — — — — — — — —I ('n \I OFFICE / BILLING \ 9 - .0 I Sc� ID -2.0 P-5 , -------I— ��—+ I \ � ANON—RATED PARTITION W/SOUNDATTEN.BLANKET SCALE: 1/2 = 1'-0 - J ��`��CTION @LOW DIVIDER SCALE: 1/2 = 1'-0" E 6 OBDY/ENTRY ID -2.0 7'-58" OLID WALL TOP OF ACOUSTICAL CEILING &SECTION @ DIVIDER SCALE: 1/2 = 1'-0" ROOM FINISH SCHEDULE ROOM WALLS FLOOR BASE REMARKS LOBBY ENTRY PT-1/WC-1 WD-1/CA-1 RB -1 NOTE #3 OFFICE/BILLING PT -5 CA -2 RB -1 OFFICE, TREATMENT ROOMS, PILATES AREA TREATMENT RM#1 PT -2 CA -1 RB -1 ENTRY THRU HALLWAY, BEHIND RECEPT. DESK TREATMENT RM#2 PT -3 CA -1 RB -1 SEE ELEV. TREATMENT RM#3 PT -4 CA -1 RB -1 THROUGHOUT STORAGE PT -6 CA -1 RB -1 STAIN TOILET PT -6 CT -1 RB -1 HALLWAY, PILATES AREA PILATES AREA PT -1 CT -1 RB -1 TREATMENT ROOM #3 (FRONT) CORRIDOR PAINT SHERWIN WILLIAMS SW -6415 HEARTS OF PALM TREATMENT #2 (MIDDLE) FINISH NOTES: 1. ALL PAINT ON DRYWALL TO BE EGGSHELL FINISH, UNLESS NOTED OTHERWISE. 2. ALL PAINT ON WOOD TO BE SEMI -GLOSS FINISH, UNLESS NOTED OTHERWISE. 3. INTERIOR DOORS, DOOR & WINDOW TRIM TO BE PT -2 (EXCEPT STOREFRONT) DOOR SCHEDULE FINISH MATERIALS LIST CODE ITEM MANUFACTURER/SOURCE STYLE/COLOR REMARKS RATING REMARKS 01 LOBBY ENTRY EXISTING PAIR CA -1 CARPET BIGELOW HOUSE OF FLOORS: 407-830-6999 CHAINSTITCH W023 3887 SPICE BOX OFFICE, TREATMENT ROOMS, PILATES AREA SV -1 SHEET VINYL ARMSTRONG NATURAL OPTIONS -WALNUT BLACK BROWN ENTRY THRU HALLWAY, BEHIND RECEPT. DESK LU -1 LUMICOR LUMICOR TIKI GRASS AB -856 -100 -AH SEE ELEV. RB -1 RUBBER BASE MERCER TO BE DETERMINED THROUGHOUT WC -1 WALLCOVERING EYKON BUSHEL IN 'SAFARI' STAIN PT -1 PAINT SHERWIN WILLIAMS TO BE DETERMINED: SW 6414 OR SW 6115 HALLWAY, PILATES AREA PT -2 PAINT SHERWIN WILLIAMS SW -6212 QUIETUDE TREATMENT ROOM #3 (FRONT) PT -3 PAINT SHERWIN WILLIAMS SW -6415 HEARTS OF PALM TREATMENT #2 (MIDDLE) PT -4 PAINT SHERWIN WILLIAMS SW -6542 VESPER VIOLET TREATMENT #3 (BACK) PT -5 PAINT SHERWIN WILLIAMS SW -6227 MEDITATIVE OFFICE PT -6 PAINT SHERWIN WILLIAMS SW -6325 CONSTANT CORAL BATHROOM AND STORAGE PT -7 PAINT SHERWIN WILLIAMS SW -6114 BAGEL CEILINGS -ALL PL -1 PLASTIC LAMINATE FORMICA 7732-58 BUTTERRUM GRANITE (MATTE) HORIZONTAL SURFACES PL -2 PLASTIC LAMINATE WILSONART 10734-60 LIMBER MAPLE SEE ELEV. PL -3 PLASTIC LAMINATE WILSONART 7935-07 SHAKER CHERRY SEE ELEV. NUMBER ROOM DECSRIPTION TYPE SIZE RATING REMARKS 01 LOBBY ENTRY EXISTING PAIR EXISTING 6'-0" X 8'-0" N/R 02 OFFICE/BILLING FLUSH POCKET - PAIR A 3'-0" X 6'-8" N/R STAIN 03 TREATMENT #1 FLUSH POCKET A 3'-0" X 6'-8" N/R STAIN 04 TREATMENT #2 FLUSH POCKET A 3'-0" X 6'-8" N/R STAIN 05 TREATMENT #3 FLUSH POCKET A 3'-0" X 6'-8" N/R STAIN 06 STORAGE FLUSH HOLLOW CORE A 3'-0" X 6'-8" N/R STAIN 07 TOILET EXISTING A 3'-0" X 6'•-8" N/R STAIN 0 DOOR TYPE I RED NEW NON—RATED PARTITION ® EXISTING WALL ® NEW NON—RATED PARTITION WITH SOUND ATTENUATION BLANKET LIFE SAFETY LEGEND 72 EGRESS WIDTH ® EXIT LIGHT EMERGENCY LIGHT -0 FIRE EXTINGUISHER - MIN. RATING FE OF 2A10BC. MOUNT EXSTINGUISHER SO THAT TOP OF EXTINGUISHER IS MORE THAN 5' A.F.F. AND BOTTOM IS NOT LESS THAN 4" A.F.F. NOTES: 1. SEE "E" SHEETS FOR ADDITIONAL ELECTRICAL AND HVAC INFORMATION. Q � W U U = Un �J l w > Fn r, (� H —� -�-� Q LTJ 0 — `o W c: 00 0 O U) 0 z u C) CL� 0 _0 0 Q JY) AdmL 00 m co00 Lo m 00 ao ICD CN W 4 rTl CD ®CD aLL ISI (D a_ CV m a� cn U � co ¢00 L O M M LL .E M CL -0 L 0 ANIL -, O DRAWN BY DAVID R. BROWN SHEET a r w 1 REFLECTED CEILING PLAN Scale: 1/4 — 1-0 LOW WALL W/ LUMICOR PANEL Scale = 1/4" = 1'0" LOW WALL W/ LUMICOR PANEL Scale = 1/4" = 1'0" VERTICAL SURFACES PL -3 ---FALSE PANEL [IEIE OPEN 111111 WAS ER! DR YE I EXISTING 2 X 4 LAY—IN WALL MOUNTED LIGHTING FIXTURE LOW WALL W/ LUMICOR PANEL Scale = 1/4" = 1'0" LOW WALL W/ LUMICOR PANEL Scale = 1/4" = 1'0" VERTICAL SURFACES PL -3 ---FALSE PANEL L-1 HORIZONTAL SURFACES s KITCHEN ELEVATION ID 2.0 Scale = 1/4" = 1'0" LEGEND MATERIAL PENDANT LIGHTING FIXTURE REMARKS WAS ER! DR YE I EXISTING 2 X 4 LAY—IN WALL MOUNTED LIGHTING FIXTURE O RECESSED CAN LIGHTING FIXTURE I SURFACE MOUNTED LIGHTING FIXTURE SLOPES TO 10'-0" L-1 HORIZONTAL SURFACES s KITCHEN ELEVATION ID 2.0 Scale = 1/4" = 1'0" LEGEND MATERIAL PENDANT LIGHTING FIXTURE REMARKS PENDANT LIGHTING FIXTURE EXISTING 2 X 4 LAY—IN WALL MOUNTED LIGHTING FIXTURE O RECESSED CAN LIGHTING FIXTURE EXISTING 2 X 4 LAY—IN SURFACE MOUNTED LIGHTING FIXTURE SLOPES TO 10'-0" WALL MOUNTED LIGHTING FIXTURE ® EXHAUST FAN SUPPLY AIR GRILLE EXISTING 2 X 4 LAY—IN RETURN AIR GRILLE 7 OFFICE COUNTER -LEFT ID 2.0 Scale = 1/4" = 1'0" 4 STORAGE/SHOE BINS ID2.0 Scale = 1/4" = 1'0" CEILING SCHEDULE ROOM MATERIAL HEIGHT REMARKS LOBBY ENTRY EXISTING 2 X 4 LAY—IN 12'-0" OFFICE/BILLING EXISTING 2 X 4 LAY—IN 12'-0" SLOPES TO 10'-0" TREATMENT RM#1 EXISTING 2 X 4 LAY—IN 10'-0" TREATMENT RM#2 EXISTING 2 X 4 LAY—IN 10'-0" TREATMENT RM#3 EXISTING 2 X 4 LAY—IN 10'-0" W STORAGE EXISTING 2 X 4 LAY—IN 10'-0" TOILET EXISTING 2 X 4 LAY—IN 10'-0" PILATES AREA EXISTING 2 X 4 LAY—IN 10'-0" Z CORRIDOR EXISTING 2 X 4 LAY—IN 10'-0" -_j NOTES: 1. SEE "E" SHEETS FOR ADDITIONAL ELECTRICAL AND HVAC INFORMATION. OFFICE COUNTER -CENTER Scale = 1/4" = 1'0" IORIZONTAL ;U RFACES RECEPTION DESK -SIDE VIEW Scale = 1/4" = 1'0" 9 OFFICE COUNTER -RIGHT ID2.0 Scale = 1/4" = 1'0" HORIZONTAL SURFACES RECEPTION DESK FRONT VIEW Scale = 1/4" = 1'0" REVISIONS BY QV/ 0 •U < W U —� W 0 f Z o m� N Q -_j m -i n Q • O �] 00 a O (n - W O U � 0 W U W O W Q 00 m 00 00 0-) Ln 00 00 ti ti o O Iu C:) z o nOn W N m C J CY) ca a) o Q 00 L N O (u Co LL IE M L F LL L rm" 10 DRAWN BY DAVID R. BROWN CHECKED DRB DATE SCALE JOB NO. SHEEP LIGHTING FIXTURE SCHEDULE TYPE DESCRIPTI❑N LAMP APPROVED MANUF./M❑DEL A 2' ; 4' DEEP RECESSED MOUNTED 3X32W T8 COOL DAYBRITE 2TG8-332-FA-21-12OV-EB2/1 FLUORESCENT FIXTURE, 3X32W, FLAT WHITE SIMKAR TK244-332-B11-120V WHITE ALUMINUM DOOR, VIRGIN HUBBELL RD3GSNA01B4-RE ACRYLIC PRISMATIC DIFFUSER, ELECTRONIC BALLAST, WIRED TWO Engineering Professional Services, Inc One Purlieu Pl. Suite 124 OUTSIDE LAMPS, MID LAMP IN (407)657-6616 - (407) 657-2262 (fax) Sensorunit@AOL.Com SEPARATE CIRCUITS. EB 4926 B 1' X 4' DEEP RECESSED MOUNTED 2X32W T8 COOL DAYBRITE 1TG8-232-FA-21-120V-EB2/1 FLUORESCENT FIXTURE,2X32W, FLAT WHITE SIMKAR TK144-232-B11-120V WHITE ALUMINUM DOOR, VIRGIN HUBBELL RD2GSNA01B4-RE ACRYLIC PRISMATIC DIFFUSER, � ELECTRONIC BALLAST, �-1 ISI C RECESSSED MOUNTED 6' CAN, WHITE PAR30 50W THOMAS TRB40W BAFFLE., D PENDANT MOUNTED FIXTURE. 60W 120V THOMAS M2612 -63-60W E WALL MOUNTED SCONCE. 60W 120V THOMAS SL 8513-8 60W F WALL MOUNTED INCANDESCENT FIXTURE 4X60W 120V THOMAS M1594-63-4X60W OVER THE MIRROR. F PENDANT MOUNTED DECORATIVE 4X60W 120V INTERI❑R DESIGNER SELECTED FIXTURE, FIXTURE. CLOSE COORDINATE REQUIREMENTS F� BEFORE BIDDING. X UNIVERSAL MOUNTED EXIT SIGN, WITH INCLUDED BEGHELLI VA4 R SA SEALED BATTERY BACKUP, WIRE FROM DEDICATED LOCK -ON CIRCUIT IN No_ CORRESPONDING LIGHTING PANEL, OR LOCAL UNSWITCHED LIGHTING CIRCUIT ACCORDING TO CODE. EM SURFACE MOUNTED ADJUSTABLE HEADS, INCLUDED BEGHELLI EL 28 SE UNV EMERGENCY LIGHTING FIXTURE, WITH SEALED BATTERY BACKUP AND 10MIN BACK -TO -NORMAL DELAY, WIRE FROM DEDICATED LOCK -ON CIRCUIT IN CORRESPONDING LIGHTING PANEL, OR LOCAL UNSWITCHED LIGHTING CIRCUIT ACCORDING TO CODE. 1) - CONTRACTOR SHALL COORDINATE BALLAST AND LAMP VOLTAGE WITH AVAILABLE VOLTAGE IN THE GIVEN AREA. 2) - ALL FIXTURES, LAMPS AND TRIMS SHALL BE SELECTED AND APPROVED BY INTERI❑R DESIGNER AND OWNER, SUBMIT FULL CUT SHEET AND SPECS, PACKAGE. 3) - ALL RECESSED MOUNTED FIXTURES SHALL BE THERMALLY PROTECTED AND SUITABLE TO BE IN CONTACT WITH INSULATI❑N. ALL EXTERIOR BALLAST SHALL BE ZERO DEGREE TYPE. 4) - ALL PENETRATI❑NS SHALL BE SUITABLE FOR THE GIVEN RATING. LAY -IN FIXTURES SHALL BE SUPPORTED DIRECTLY FROM THE ROOF/(OR UPPER FLOOR) STRUCTURE. 5) - ALL FIXTURES SHALL BE CENTERED IN BOTH DIRECTI❑NS WITHIN EACH ROOM, FIXTURES SHOWN AT DORS SHALL BE CENTERED WITH THE DOOR, 6) - THE DESCRIPTI❑N SUPERCEEDS THE CAT#, IN CASE OF DISCREPANCY CONSULT THE ENGINEER BEFORE ORDERING. 7) - SEE DRAWING E2 FOR PANEL SCHEDULE AND CIRCUIT INFORMATION. Y GENERAL ELECTRICAL PROVISIONS PREBIDING CONDITIONS, Before bidding or pricing this job, this contractor shall secure a full set of drawings and specs including all the diciplines (Mechanical, Arch I tectura 1, P t ub I ng, etc. ), v i s i t the s i te, become fam i i i ar w i th the shopping mall landlord requirements consult with the local authorities and in general familiarize him/herself with alt the existing conditions and requirements. This is an existing building and therefore the contractor will be required to coordinate with many existing conditions and existing equipment and installations that shall be reused. Include all provisions and requirements in your price, no allowance will be made for coordination with existing conditions. All required work shall be done with minimal disturbance and disruption (nolce, service disruption) to existing tenants, work may need to be scheduled on weekends or after hours. Provide all labor, materials and equipment for a complete and operating electrical system. Codes and Standardsi All electrical work shall be in strict compliance with the National Electrical code, the local county electrical code and Power ING TO REMAIN Company standards. All materials shall be new and free from defects, and shall bear the underwrIters'Labe l. Permits, Certifications, Fees and Notices, Secure and pay for all required by the work of this Division. All electrical work shall be done in a neat and workmanlike manner. FLOOR PLAN Special Requirements, Submit three (3) copies of technical Information on all equipment in binders, Mark-up prints of the design drawings with red pencil as items are installed, and submit two copies showing an accurate 'As -Built' record of the entire system. Give the owner instructions in operation of the system. Secure from the owner a signed memo stating that technical information, as -built drawings and instructions in operation have been received. Submit memo to the Architect. BASIS OF MATERIALS AND METHODS Condu i ti A l l w I res sha l l be concea led i n ga lvan I zed condu i t, ( 1/2' m i n. ) or thinwall (EMT) including low voltage work and grounding wires. When conduit is located below slab, on grade or under ground it shall be PVC Schedule 40 (3/4' min.). Provide empty conduits with pull strings, as indicated. Conduits shalt be s i zed per N. E. C. Wire; Wire shall be copper, 600v, where not specified, minimum size shall be #12 AWG type THW. Pane I,looardsi Provide new breakers in exlsting panels whenever needed, all breakers shall be fully compatible with existing panels. Provide new panels and breakers If necessary, new panels shall be NLAB BOLTED -ON circuit breaker type, copper bus,ground and neutral, manufactured by General E l ectr I c, Square -D, Gou l d, I. T. E. , Cut t er Hammer or West I nghouse. Pane l boards box minimum width shall be 20', equipped with hinged door and flush handle and lock. It shall be flush mounted unless otherwise indicated in panel schedule. Provide circuit directory In frame with protective covering mounted on the back of the door, completely filled In (typewritten). Short Circuit Rating; All panelboards and distribution equipment shall have short circuit rating that shall be equal or larger than that available from the Utility Company's system. Lightning Surge Protection Systema Provide a lightning protection system as shown and specified herein. Work shall include water tight enclosure add all accessories and appurtenances required for a complete Installation. The equipment as specified shall be General Electric Model Series 9L15ECC0C1 or approved equal. SCALE 1/4' = 1' - 0' Electric Motor and Equipment Wirings Include complete power system Including wlring, starter and fused disconnect swItclh, for all motor driven equipment. When equipment Is provided with a 'package' control panel which Includes starter, this contractor will not provide starter. Installation and wiring of control equipment furnished under other sections shall be wired under this section. Motor connections shall be made with flexible conduit. Starters shall be all of one manufacturers G. E. , West I nghouse, Square -D, Cut ler Hammer, S I emens or I. T. E. . Provide an overload element In each phase. Air Conditioning equipment disconnect shall Include Air Conditioning -type breaker. Switchings All general areas shall be switched from the admin office as indicated in the floor plans, all fluorescent fixtures shall be circuited so that half of the lamps (within each fixture) shalt be able to be controlled by a separate switch, for Lighting leve l control, all fluorescent f l c -tures shall be dual circuit dual ballast. For this purpose reuse existing split bus panels, existing contactors, or provide new multycircult contactors to be able to do the switching in a practical and uniform manner. Apparatus Identiflcatloni Panelboards, motor disconnect switches, dimmers, starters and other apparatus used for the operation of control of circuits, appliances or equipment shalt be properly identified by means of engraved laminated plastic descriptive nameplates mounted on the apparatus using contact cement. J. Boxesi Drawings are only schematic, to show functional relationship and Load grouping, Include all J. Boxes as required by NEC, for all fixtures, sp t I ces, etc. Provide Walker system floor duct to handle all the wlring and receptacle requirements of the excersise equipment. Grounding System, Provide grounding system in compliance with NEC 250, Final Payment; Final payment will not be author Ized until, a) All Equipment have been properly Identlifled. b) All Panel Directories have been property filled—in. c) F I na l as-bu I l t draw I ngs have been subm I -tted. TELEPHONE SYSTEM NOTES ALL TELEPHONE OUTLETS SHALL BE PROVIDED WITH A CONDUIT, EXTEND TO THE EXISTING TELEPHONE BACKBOARD. CONDUIT SIZE SHALL BE A MINIMUM OF 3/4' WHEN SERVING ONE OUTLET. MINIMUM SIZE SHALL BE INCREASED 1/4' FOR EACH ADDITI❑NAL OUTLET SERVED, WITH A MAXIMUM OF 3 OUTLETS SERVED BY ANY SINGLE CONDUIT. ELECTRICAL CONTRACTOR SHALL VISIT SITE AND INCLUDE IN HIS PRICE THE COST OF UPGRADING OR EXPANDING EXISTING TELEPHONE SYSTEM TO INCLUDE ALL THE NEW PHONES SHOWN ON THIS DRAWINGS. OBTAIN ADDITI❑NAL LINES FROM THE TELEPHONE COMPANY AS PER OWNER'S REQUIREMENTS. PROVIDE TELEPHONE BACKBOARD 4' X 4', WITH GROUND WIRE # 6 AWG, TWO DUPLEX RECEPTACLES CENTERED AT TOP OF THE BACKBOARD, AND ALL ADDITIONAL REQUIREMENTS ACCORDING TO PHONE COMPANY STANDARDS. FIRE ALARM SYSTEM NOTES UPGRADE AND OR EXPAND EXISTING FIRE ALARM PANEL TO INC❑RP❑RATE THE DEVICES SHOWN ON THIS DRAWINGS. THE DEVICES SHOWN, QUANTITY AND L❑CATION ARE MINIMUM ❑NLYj FIRE ALARM SYSTEM SHALL BE INSTALLED BY LICENSED FIRE ALARM CONTRACTOR WITH NO LESS THAN 5 YEAR OF EXPERIENCE IN THE AREA, SPECIALIZING IN FIRE ALARM SYSTEMS, SYSTEM SHALL COMPLY WITH ALL LOCAL FIRE MARSHAL REQUIREMENTS. APPROVED EQUIPMENT, SIMPLEX, NOTIFIER. THE FIRE ALARM CONTRACTOR IS RESPONSIBLE FOR PR❑VIDE DETAILED DRAWINGS AND SUBMITTALS CERTIFIED BY REGISTERED ENGINEER WITH EXPERIENCE IN FIRE ALARM SYSTEMS. THE FIRE ALARM SYSTEM SHALL BE INTERCONNECTED WITH THE THE WATER FLOW SWITCH (IF SPRINKLER SYSTEM IS AVAILABLE), AIR HANDLERS, DUCT SMOKE DETECTORS AND WITH ANY OTHER REQUIRED BY THE FIRE MARSHAL AND LOCAL AUTHORITIES. SOME OF THE EQUIPMENT TO BE PROVIDED AREi PULL STATIONS, AREA SMOKE DETECTORS, DUCT SMOKE DETECTORS, AIR HANDLER SHUT DOWN RELAYS, AUDIBLE AND VISUAL ALARM DEVICES. THIS DOCUMENT IS VOID WITHOUT THE RAISED SEAL. ROBERT J, PIRELA, PE - FL LIC# 38783 Oj 'i a. 3 i5 O i a v a a 0 C 0 ai R L S m v d a ai 0 0i C C W 0 N s T 0 U wn7l Name ana Aaaress EAYALA Sheet El Date 10/12/05 Scale AS INDICATED Engineering Professional Services, Inc One Purlieu Pl. Suite 124 Winter Park, Fl. 32793 (407)657-6616 - (407) 657-2262 (fax) Sensorunit@AOL.Com EB 4926 V � Q �-1 ISI .� Nd Ct V �ct-i P®1 F� No_ Revision/Issue Date Drawing Title Lighting Floor Plan 0 EAYALA Sheet El Date 10/12/05 Scale AS INDICATED 0 PANEL P EXISTING PANEL NEW BREAKERS VOLTAGE; 208/120V 30 4W MAINS; 200A 30 MLO CABINET, SURFACE MOUNTED -FIRE 42 SPACES WIDTHSTAND RATING; 35K AIC CONNECTED LOAD; 31.8 KVA CKT# AMPS POLES KVA LOAD DESCRIPTION AND FEEDER 1 20 1 1.0 A GENERAL LIGHTING 2 20 1 0.8 -EMERGENCY LIGHTING PER SCHEDULE, GENERAL LIGHTING 3 20 1 0.5 Engineering Professional Services, Inc GENERAL LIGHTING 4 20 1 0.9 - 120V 15A GEN. PURPOSE REC. MOUNT 4" ABOVE COUNTER TOP LEVEL, GENERAL LIGHTING 5 20 1 1.0 @ GENERAL LIGHTING 6 20 1 0.3 COMPUTER PORTS, EMERGENCY LIGHTING (LOCK ON BREAKER) 7 20 1 0. 6 EWC 8 20 1 0. 4 TOILET REC, 9 20 1 0.2 ® PILATES RECEPTACLE 10 20 1 0.2 PILATES RECEPTACLE it 20 1 0.2 PILATES RECEPTACLE 12 20 1 0.2 PILATES RECEPTACLE 13 20 1 0.2 PILATES RECEPTACLE 14 20 1 0.2 PILATES RECEPTACLE 15 20 1 0.2 PILATES RECEPTACLE 16 20 1 0.6 RECEPTI❑N RECEPTACLES 17 20 1 0.4 RECEPTI❑N RECEPTACLES 18 20 1 O, 4 COMPUTERS REC. 19 20 1 O, 6 COMPUTERS REC. 20 20 1 O, 6 COMPUTERS REC, 21 20 1 0. 6 COMPUTERS REC. 22 20 1 0.8 HYDROTHERAPY 23 20 1 0.6 HYDROTHERAPY 24 20 1 0.6 HYDROTHERAPY 25, 27, 29 50 3 15, 3 RTU ( EXISTING) 26,28 50 2 8. 0 INSTANT WATER HEATER - 3 # 8 01' 30 20 1 1. 2 EXTERIOR SIGN (: ❑N TIMER) 31,33 50 2 5. 0 DRYER - 3 # 8 01' 32 20 1 1. 5 WASHER PR❑VIDE T❑RK TIMER WITH RESERVE WIND TO CONTROL EXTERIOR SIGN,. ELECTRIC LEGEND FLOOR PLAN SCALE 1/4' = 1' - 0' LOAD CALCULATIONS SUMMARY BASED ON NEC 2002 208/120V 3PH 4W SPACE AREA 1500SF RETAIL CONNECTED LOAD, 43225KVA TYPE; VA LIGHTING 1500 x 3 x 1.25 5625 RECEPTACLES 38X200 7600 HVAC ( HEATING) 15300 SIGNS 1200 1200 EWH 8000 WASHER 1500 DRYER 5000 TOTAL CONNECTED, 43225 MIN. SERVICE SIZE, 43225/(208 X 1/73) 120AMPS GROUND IS NOT SHOWN IN THIS DRAWINGS, ALWAYS INCLUDE FULL SIZE NEUTRAL AND GROUNDING, THE CIRCUIT NUMBERS SHOWN ON THIS SCHEDULES AND DRAWINGS ARE ONLY TO INDICATE GROUPING, CONTRACTOR SHALL VERIFY PHASE BALANCE AND MAKE PANEL ADJUSTMENTS TO ACHIEVE PROPER PHASE BALANCE, BEFORE ORDERING ANY EQUIPMENT, C❑ORDINATE WITH POWER CO. AVAILABLE VOLTAGE, SERVICE CAPACITY AND FAULT CURRENT AT TRANSFORMER SECONDARY, COORDINATE PANIEL TYPE AND RATING AS WELL AS FIXTURE SPECS WITH THIS DATA, BREAKER AND WIRE SIZE IN EQUIPMENT CIIRCUITS SHALL BE CLOSE COORDINATED WITH EQUIPMENT NAMEPLATE iAND MANUFACTURER REC❑MMENDATIDNS. SOME CIRCUITS LONGER THAN 75' WILL NEIED RESIZING FOR VOLTAGE DROP, WHEN IN DOUBT REQUEST CLARIFICATION FROM THE ENGINEER. INCLUDE 20% SPARE CAPACITY IN EVERY PANEL AND NO LESS THAN 10% INSTALLED SPARE BREAKERS. -FIRE — 2 X 4 FLUORESCENT FIXTURE, TYPE AND SPES PER SCHEDULE, FAP —SCONCE AS PER SCHEDULE F❑ 0 —INCANDESCENT FIXTURE TYPE AND SPECS. PER SCHEDULE, A 0000 - 4' WALL INCANDESCENT STRIP, TYPE AND SPES PER SCHEDULE, O-SMOKE -EMERGENCY LIGHTING PER SCHEDULE, -DUCT SMOKE -EXIT SIGN PER SCHEDULE, Engineering Professional Services, Inc One Purlieu Pl. Suite 124 - 120V 15A GEN. PURPOSE RECEPTACLE, (407)657-6616 - (407) 657-2262 (fax) Sensorunit@AOL.Com - 120V 15A GEN. PURPOSE REC. MOUNT 4" ABOVE COUNTER TOP LEVEL, EB 4926 -120V QUAD RECEPTACLE, @ - 240V 1PH RECEPTACLE, Q -MULTYPORT OUTLET COMBO, PHONE, FAX AND COMPUTER PORTS, -ELECTRIC PANEL, .... 25 -FUSED DISCONNECT. P . �7''>: .� —JUNCTION BOX, O-� ® -RECESSED FLOOR BOX tri ® -CEILING OUTLET FLOOR PLAN SCALE 1/4' = 1' - 0' LOAD CALCULATIONS SUMMARY BASED ON NEC 2002 208/120V 3PH 4W SPACE AREA 1500SF RETAIL CONNECTED LOAD, 43225KVA TYPE; VA LIGHTING 1500 x 3 x 1.25 5625 RECEPTACLES 38X200 7600 HVAC ( HEATING) 15300 SIGNS 1200 1200 EWH 8000 WASHER 1500 DRYER 5000 TOTAL CONNECTED, 43225 MIN. SERVICE SIZE, 43225/(208 X 1/73) 120AMPS GROUND IS NOT SHOWN IN THIS DRAWINGS, ALWAYS INCLUDE FULL SIZE NEUTRAL AND GROUNDING, THE CIRCUIT NUMBERS SHOWN ON THIS SCHEDULES AND DRAWINGS ARE ONLY TO INDICATE GROUPING, CONTRACTOR SHALL VERIFY PHASE BALANCE AND MAKE PANEL ADJUSTMENTS TO ACHIEVE PROPER PHASE BALANCE, BEFORE ORDERING ANY EQUIPMENT, C❑ORDINATE WITH POWER CO. AVAILABLE VOLTAGE, SERVICE CAPACITY AND FAULT CURRENT AT TRANSFORMER SECONDARY, COORDINATE PANIEL TYPE AND RATING AS WELL AS FIXTURE SPECS WITH THIS DATA, BREAKER AND WIRE SIZE IN EQUIPMENT CIIRCUITS SHALL BE CLOSE COORDINATED WITH EQUIPMENT NAMEPLATE iAND MANUFACTURER REC❑MMENDATIDNS. SOME CIRCUITS LONGER THAN 75' WILL NEIED RESIZING FOR VOLTAGE DROP, WHEN IN DOUBT REQUEST CLARIFICATION FROM THE ENGINEER. INCLUDE 20% SPARE CAPACITY IN EVERY PANEL AND NO LESS THAN 10% INSTALLED SPARE BREAKERS. -W = FOR WALL PHONE @ 60' AFF. -WP = WEATHER PROOF. -GFIC = GROUND FAULT CIRCUIT INTERRUPTER. -Sm = SWITCH WITH MOTION SENSOR -Sp - SWITCH WITH PILOT LIGHT (❑N WHEN ❑N) ELECTRIC ABBREVIATIONS MARK D E S C R I P T 1 N A AMPS AFF ABOVE FINISHED FLOOR AIC AMPS INTERRUPTING CAPACITY CB CIRCUIT BREAKER CIRC CIRCUIT D DIMMER DF DIVERSITY FACTOR EMT ELECTRIC METALLIC TUBING FAP FIRE ALARM PANEL FL FLUORESCENT GFCI GROUND FAULT CIRCUIT INTERRUPTER INC INCANDESCENT KA THOUSAND AMPS KVA KIL❑V❑LT AMPS KW KIL❑WATTS M METER N/A NOT APPLICABLE NIC NOT IN CONTRACT NTS NOT TO SCALE PH PHASES PNL PANEL P POLES REC RECEPTACLE SPEC SPECIFICATION S SWITCH T TRANSFORMER V VOLTS WP WEATHER PROOF XP EXPL❑SI❑N PR❑EIF THIS DOCUMENT IS VOID WITHOUT THE RAISED SEAL, t> ROBERT J, PIRELA, PE - FL LICtf 38783 I Firm Name and Address -FIRE ALARM CONTROL PANEL FAP F❑ -FIRE ALARM PULL STATION A -FIRE ALARM (AUDIO/VISUAL) ANNUNCIATOR DEVICE O-SMOKE DETECTOR -DUCT SMOKE DETECTOR -W = FOR WALL PHONE @ 60' AFF. -WP = WEATHER PROOF. -GFIC = GROUND FAULT CIRCUIT INTERRUPTER. -Sm = SWITCH WITH MOTION SENSOR -Sp - SWITCH WITH PILOT LIGHT (❑N WHEN ❑N) ELECTRIC ABBREVIATIONS MARK D E S C R I P T 1 N A AMPS AFF ABOVE FINISHED FLOOR AIC AMPS INTERRUPTING CAPACITY CB CIRCUIT BREAKER CIRC CIRCUIT D DIMMER DF DIVERSITY FACTOR EMT ELECTRIC METALLIC TUBING FAP FIRE ALARM PANEL FL FLUORESCENT GFCI GROUND FAULT CIRCUIT INTERRUPTER INC INCANDESCENT KA THOUSAND AMPS KVA KIL❑V❑LT AMPS KW KIL❑WATTS M METER N/A NOT APPLICABLE NIC NOT IN CONTRACT NTS NOT TO SCALE PH PHASES PNL PANEL P POLES REC RECEPTACLE SPEC SPECIFICATION S SWITCH T TRANSFORMER V VOLTS WP WEATHER PROOF XP EXPL❑SI❑N PR❑EIF THIS DOCUMENT IS VOID WITHOUT THE RAISED SEAL, t> ROBERT J, PIRELA, PE - FL LICtf 38783 I Firm Name and Address ct 7AYALA Shoot E2 Dat® 10/12/05 Scale AS INDICATED Engineering Professional Services, Inc One Purlieu Pl. Suite 124 Winter Park, Fl. 32793 (407)657-6616 - (407) 657-2262 (fax) Sensorunit@AOL.Com EB 4926 4.) 0 .� C tri PSI m Q� 4i 00 No_ Revision /Ilssue nntP. ct 7AYALA Shoot E2 Dat® 10/12/05 Scale AS INDICATED NEW SINK, STACKABLE WASHER AND DRYER IN CABINET, EXTEND WATER O.V!ER THE CEILING. PR❑VIDE UNDER THE COUNTER INSTANT WATER HEATER, CHRON❑MITE S80-BKW-208V 02'SAN CUT AND PATCH SLAB AS NEEDED.................. .......... ........ PLUMBING SPECIFICATIONS PLUMBING SPECIFICATIONS GENERAL THE GENERAL MECHANICAL SPECIFICATIONS APPLY TO THE WORK SPECIFIED IN THIS SECTION. SCOPE OF WORK FURNISH AND INSTALL COMPLETE PLUMBING SYSTEM AS INDICATED ON THE DESIGN DRAWINGS AND AS OUTLINED WITHIN THESE SPECIFICATIONS. WORK SHALL INCLUDE BUT NOT BE LIMITED TO THE FABRICATION AND/OR INSTALLATION OF THE SCHEDULED PLUMBING FIXTURES AND RELATED PIPING. THE COMPLETED PLUMBING SYSTEM SHALL MEET ALL APPLICABLE CODES AND STANDARDS. WATER SUPPLY SYSTEM EXTEND WATER SERVICE AS INDICATED ON DESIGN DRAWINGS. ALL SOLDER SHALL BE LEAD FREE. PROVIDE SHOCK ABSORBERS AND VACUUM BREAKERS WHERE REQUIRED. PIPE AND FITTINGS ABOVE GROUND - TYPE L HARD COPPER AND WROUGHT COPPER FITTINGS, WITH SOLDERED JOINTS (USE ONLY "LEAD FREE" SOLDER). PIPE AND FITTINGS BELOW GROUND - TYPE "K" SOFT COPPER. PROVIDE POLYBUTYLENE WRAPPING. VALVES (2-1/2 INCH AND SMALLER) TWO PIECE 600 PSI WSP FULL PORT BRONZE BODY BALL VALVE WITH THREADED ENDS, LOCKABLE LEVER HANDLE AND REPLACEABLE TEFLON OR TFE SEATS CHLORINATION - BEFORE BEING PLACED IN SERVICE ALL WATER DISTRIBUTION SYSTEMS SHALL BE STERILIZED WITH CHLORINE IN ACCORDANCE WITH AWWA C-601-54 STANDARD PROCEDURE FOR DISINFECTING WATER MAINS. INSULATE HOT WATER AND HOTWATER RETURN PIPING WITH 1" ARMAFLEX RP INSULATION OREQUAL. INSULATION TO BE FIRE RATED FOR USE IN RETURN AIR PLENUM. �7�I�L�[�P►��L�141�Y��1��1►F�CI�I��CI917�L���i ROUGH -IN AND CONNECT WATER, WASTE, AND VENT TO COMPLETE THE INSTALLATION OF EQUIPMENT LISTED ON THE DRAWINGS. PLUMBING FIXTURES SHALL BE PROVIDED COMPLETE AS SHOWN ON THE DRAWINGS WITH ALL REQUIRED SUPPLY, WASTE, SOIL, AND VENT CONNECTIONS, TOGETHER WITH ALL FITTINGS, SUPPORTS, FASTENING DEVICES, COCKS, VALVES, AND TRAPS. ALL FIXTURES SHALL HAVE STOP VALVES ON ALL WATER CONNECTIONS. ALL EXPOSED METAL TRIM ON ALL FIXTURES SHALL BE POLISHED CHROMIUM PLATED. ALL EXPOSED PIPES EXTENDING FROM WALL SHALL HAVE CHROMIUM PLATED BRASS ESCUTCHEON MOUNTED AGAINST WALL. EXPOSED PVC PIPING AND P -TRAPS ARE THE PLUMBING FIXTURES SHALL BE ROUGHED -IN ACCORDANCE WITH MANUFACTURER'S "ROUGH -IN INFORMATION". PROVISIONS FOR MOUNTING WALL FIXTURES SHALL BE MADE WHILE THE WALL IS BEING BUILT. DRAINAGE SYSTEM EXTEND PIPING AS INDICATED ON THE DRAWINGS. PIPE SLOPE: 2-1/2 INCH DIAMETER AND LESS SHALL BE INSTALLED WITH A FALL OF NOT LESS THAN 1/4 INCH PER FOOT. 3 INCH DIAMETER OR LARGER SHALL BE INSTALLED WITH A FALL NOT LESS THAN 1/8 INCH PER FOOT. PIPE AND FITTINGS: 1. SCHEDULE 40 PVC 2. DRAIN, WASTE AND VENT PIPING LOCATED IN FIRE RATED WALL ASSEMBLIES AND RETURN AIR PLENUMS SHALL BE SERVICE -WEIGHT CAST IRON WITH SPIGOT FITTINGS. PROVIDE CLEANOUTS EVERY 75 FEET, AT CHANGES IN DIRECTION, AND AT BASE OF SOIL AND WASTE STACKS. SHOCK ARRESTOR: SIOUX CHIEF WALL CLEANOUT: ZURN, JONESPEC, JOSAM OR EQUAL FLOOR CLEANOUT: ZURN, JONESPEC, JOSAM OR EQUAL. VENTS SHALL BE EXTENDED TO EXTERIOR OF BUILDING NO STUDOR VENTS ALLOWED. FLOOR PLAN SCALE 1/4' = V - 0' UNIVERSAL TOP/BOTTOM BEAM CLAMP EQUAL TO B -LINE TYPE 19-SP69 3/8'0 MIN. HANGER ROD COUPLING ADJUSTABLE CLEVIS HANGER EQUAL TO B -LINE TYPE 10 -SP -69 PIPE NOTES, ' 1. SIZE HANGER AND CLAMP TO ADEQUATELY SUPPORT LOAD (REFER TO B -LINE HANGER CATALOG). 2. FOR COPPER TUBING USE COPPER PLATED OR PAINTED B317UCT, FELT LINED B3170F, OR PLASTIC COATED HANGERS, PIPE SUPPORT DETAIL- SCALE, NON II JIB Vf I �G i I I 2 p� J WA TE �INDN� IN e c T A 8pTERQUN R��R OVNET, I QR RINsTgNDENE 8� CMR�N�M ITE CLEANO PLUG SOIL O WASTE D SECURED INUM COVER LAR TO ZURN L Z-1469 TYPICAL WALL CLEANOUT (WCO) DETAIL SCALEi NONE THIS DOCUMENT IS VOID WITHOUT THE RAISED SEAL. ROBERT J, PIRELA, PE - FL LIC# 38783 8 a 3 ZS U 0 L D_ T a 0 0 C R i Ul GJ L Ln s v L 0 0 0 Ln v 0 n_ QJ m W 0 N m CLL T U r hrm Name and Address Protect AYALA 7 Sheet Date 10/12/05 Scale AS INDICATED Engineering Professional Services, Inc One Purlieu Pl. Suite 124 Winter Park, Fl. 32793 (407)657-6616 - (407) 657-2262 (fax) Sensorunit@AOL.Com EB 4926 n U � rTl .� 7� l (® •� Ct V) Cd 0C l M� No_ Revision/Issue Date Drawing Title Plumbing Floor Plan and p Protect AYALA 7 Sheet Date 10/12/05 Scale AS INDICATED