Loading...
1301 WP Ball Blvd - BC04-002569 (SPORTS AUTHORITY) (NEW STORE- SHELLY ONLY) (A)PERMITADDRESS CONTRACTOR Young Contracting Co. Inc. 8215 Roswell Rd Bldg. 400 ADDRESS Atlanta, GA 30350 CGC053552 770-522-9270 FAX 770-522-9273 PHONE NUMBEt-, PROPERTY OWNER ADDRESS North American Properties LLC 1080 Holcomb Bridge Bldg 200 Ste. 150 Roswell, GA 30076 770-325-4912 PHONE NUMBER ELECTRICAL CONTRACTOR MECHANICAL CONTRACTOR PLUMBING CONTRACTOR MISCELLANEOUS CONTRACTOR PERMIT NUMBER MISCELLANEOUS CONTRACTOR PERMIT NUMBER FEE FEE SUBDIVISION PERMIT # �'1– J — DATE �� o Q PERMIT DESCRIPTION PERMIT VALUATION SQUAREFOOTAGE d d Cn Cn c� 0 d H W SANFORD FIRE DEPARTMENT FIRE PREVENTION DIVISION D: 300 N. Park Ave., Sanford, FI. 32771 / P. O. Box 1788, Sanford, FI. 32772 (407 302-2520 I FAX (407) 302-2526 Plans Review Sheet Comment: Fire Department will require (2) two "31 JX" phone lines for fire alarm monitoring. hour emergencies to be placed in "Knox Box" 1.4 Battery Calculations:_ Verified & F.D. will test on Battery 1.5 Monitoring — Required on all tamper, fire sprinkler flow switches, 1.6 Duct Detectors- Required for local notification only Ten total , ok ELECT. RM MENS ROOM W❑MANS ROOM RTU 1 t5 'S CASH ROOM STAFF ROOM DIST MNGRS ❑FFICC\ GENERAL ❑FFICE MNGRS ❑FFICE 95 SHIPPING AND RECEIVING GUN STORAGE TECH CENTER 95 9J 95 95 mu _ SALES AREA RTU z RTU 5 99 95 95 1/8 INCH 1 RTU 3 TU 6 RTU 9 95 95 95 DRIVING CAGE RTU 7 —7 RTU 10 SALES AREA KI . BY: Sanford Date: C' 95 z45 CLUB STORE SEC CLOS--T REVISIONS NO. DATE REMARKS IT— C) C G C m OG ',ky r G m n c �- zLu� f c a � [—� Q L1.. m REVISIONS NO. DATE REMARKS This drawing is the property of ACTION SECURITY SERVICE and may not be used on any other project, or reproduced in part or whole without permission of ACTION SECURITY SERVICE, INC. PHONE (407) 831-6003 JOB NUMBER SPORTS AUTHORITY DATE 02/15/05 DRAWN BY RWT CHECKED BY RPP SHEET NUMBER FA1 19 IT— C) C J o m (Y'� . � [—� J Q L1.. m 0 0— O O o � z a � U) This drawing is the property of ACTION SECURITY SERVICE and may not be used on any other project, or reproduced in part or whole without permission of ACTION SECURITY SERVICE, INC. PHONE (407) 831-6003 JOB NUMBER SPORTS AUTHORITY DATE 02/15/05 DRAWN BY RWT CHECKED BY RPP SHEET NUMBER FA1 19 NOTE: ALL STROBES ARE TO BE AT 95 CANDELLA UNLESS OTHERWISE NOTED ON PLANS. FIRE ALARM NOTES: A. PROJECT INCLUDES: 1. ADDRESSABLE, MICROPROCESSOR -BASED FIRE DETECTION SYSTEM WITH MANUAL AND AUTOMATIC ALARM INITIATION INCLUDING SUPERVISORY ALARM BY DUCT DETECTORS. B. PRODUCTS: 1. FIRE ALARM SYSTEM CHARACTERISTICS A. SYSTEM SHALL BE MIRTONE QS1 WITH DIALER, INTELLIGENT, AND EXPANDABLE. 2. FIRE ALARM SYSTEM COMPONENTS: A. MANUAL PULL STATIONS: GSA -M270 B. SMOKE DETECTORS: GSA-PS/SB C. DUCT DETECTORS: GSA-PS/SB/DH W/SAMPLING D. THERMAL DETECTORS: GSA-HFS E. AUDIO VISUAL DEVICE (CEILING): MGC-HDVM F. AUDIO VISUAL DEVICE (HORN WALL): MG1 -HDVM G. VISUAL ALARM DEVICES (STROBE): MG1 -VM H. REMOTE ANNUNCIATOR: MIR -QS 1 -CPU -1 I. ADDRESSABLE REMOTE RELAY: GSA -CR TUBES AS REQUIRED J. ADDRESSABLE WATERFLOW/TAMPER MODULE: GSA-WTM K. AUTO DIALER: DLD L. DUCT DETECTOR REMOTE TEST STATION: GSA-DTS C. THE ACTIVATION OF ANY INITIATING DEVICE SHALL SEND A SIGNAL THROUGH THE HORNS AND ENERGIZE THE STROBES. THE DEVICE IN ALARM SHALL BE ANNUNCIATED AT THE FIRE ALARM CONTROL D. EACH SIGNALLING CIRCUIT SHALL BE ELECTRONICALLY SUPERVISED BY AN END OF THE LINE RESISTOR. ANY TROUBLE CONDITION SHALL BE ANNUNCIATED AT THE FIRE ALARM PANEL. E. THE SYSTEM IS A 'POWER LIMITED' TYPE. F. THE SYSTEM SHALL HAVE BATTERY BACKUP FOR 24 HOURS IN THE SUPERVISORY MODE AND 5 MINUTES IN ALARM CONDITION. (2002 CODE) G. THE SYSTEM SHALL COMPLY WITH NFPA 70 CHAPTER 760. H. THE INSTALLATION SHALL COMPLY WITH ANSI 117.1. I. ALL DEVICES SHALL BE UL LISTED FOR FIRE USE. J. FIRE ALARM SYSTEM WILL BE INSTALLED, TESTED AND MAINTAINED IN ACCORDANCE WITH NEPA 72 2000 EDITION AND ALL WIRING WILL CONFORM TO NFPA 70 ARTICLE 760. FIRE ALARM LEGEND INTELLIGENT FA PANEL ALL POINTS INDIVIDUAL POINTS PANEL. 120 INTELLIGENT FA PANEL ALL POINTS INDIVIDUAL POINTS REVISIONS NO. DATE REMARKS lia J co J C0 T a M r 'N M UL This drawing is the property of ACTION SECURITY SERVICE and may not be used on any other project, or reproduced in part or whole without permission of ACTION SECURITY SERVICE, INC. PHONE (407) 831-6003 JOB NUMBER SPORTS AUTHORITY DATE 02/15/05 DRAWN BY RWT CHECKED BY RwT SHEET NUMBER FIRE ALARM DEVICE LEGEND INTELLIGENT MANUAL PULL STATION MIRTONE GSA -M270 INTELLIGENT SMOKE DETECTOR OSA-PS GENESIS CEILING MOUNT H/S IOMCD MIRTONE MGC-HDVM -. F. GENESIS STROBE MIRTONE MGI -VM INTELLIGENT DUCT DETECTOR GSA DH/PS FIRE ALARM CONTROL PANEL MIRTONE OS1 INTELLIGENT FA PANEL FIRE ALARM TERMINAL CABINET MFC- -R INTELLEGENT RELAY MODULE GSA -CR VIT14 WATERFLOW TAMPER MODULE GSA-WTM L'iPS BOOSTER POWER SUPPLY MIRTONE MIR-8PSI0 �F INTELLIGENT HEAT DETECTOR GSA-HFS ® FIRE ALARM ANNUNCIATOR 2-SLCDA-C W/SAN-MIC2 as END OF LINE RESISTOR EOL RESISTOR FLAW SWITCH EXISTING TAMPER SWITCH EXISTING FPL /14/2 GABLE (INO"TMG) FIRE PLENUM CABLE - FPL #18/2 CABLE (INITIATING) FIRE PLENUM CABLE - FPL #18/2 CABLE (SIGNALING TRIP) FIRE PLENUM CA13L.E PANEL. 120 INTELLIGENT FA PANEL ALL POINTS INDIVIDUAL POINTS REVISIONS NO. DATE REMARKS lia J co J C0 T a M r 'N M UL This drawing is the property of ACTION SECURITY SERVICE and may not be used on any other project, or reproduced in part or whole without permission of ACTION SECURITY SERVICE, INC. PHONE (407) 831-6003 JOB NUMBER SPORTS AUTHORITY DATE 02/15/05 DRAWN BY RWT CHECKED BY RwT SHEET NUMBER f SANFORD FIRE DEPARTMENT FIRE PREVENTION DIVISION 300 t4. Pack -Ave., Sanford, FI. 32771 / P. O. Box 1788, Sanford, FI. 32772 (407302-2520 / FAX (407) 302-2526 Plans Review Sheet Date: October 26, 2004 Business Address: 1301 W.P. Ball Blvd Occ. Ch. #36 Mercantile Business Name: Shoe Carnival Ph.( ) Ordinary Hazard Group #2 — 02 g.p.m @1500 sq ft 324 Fire sprinkler head install Maximum storage height Ft. per desighn criteria Application — Per N.F.P.A. 413-1999 Ed, Point ouServ__�ce " Alty from e�tex or of b�llding w r , 1