Loading...
4005 W 1 St - BC06-000989 (NEW BUILDING - GAZEBO) (A) (2)CONTRACTOR ADDRESS MCKEE CONSTRUCTION P 0 BOX 471366 _ LAKE MONROE, FL 32747 407-323=1150 PHONE NUMBER PROPERTY OWNER ADDRESS PHONE NUMBER NIGHT OWL PROPERTIES LLC 854 WOODBARK COVE SANFORD, FL -32771 - ELECTRICAL CONTRACTOR MECHANICAL CONTRACTO PLUMBING CONTRACTOR MISCELLANEOUS CONTRACTOR PERMIT NUMBER FEE MISCELLANEOUS CONTRACTOR PERMIT NUMBER FEE SUBDIVISION PERMIT #C * 04 tol DATE , "Oka PERMIT DESCRIPTION ms PERMIT VALUATION SQUARE FOOTAGE r y1 8'0"to 24'0" TYPICAL EARTH ANCHORS TYPICAL LUS26 HANGER AT EACH CORNER AT FAPP giNir_i F .inirT TYPICAL 4" x 4" SKIDS AT 4 PLACES AND ATTACH TO OUTER BAND W/ A33 CLIP AT 4 PLACES 0 ATTACH RAFTER TO 2"x10" WITH �5) 8 X 3" SCREWS (1) 0 T P, (2) PER SIDE. 2" X 6" P.T. RAFTERS MAX. 36" O.C. ITTACH RAFTERS TO 2"x 8" RIDGE RIDGE W/(5) #8 X 3" SCREWS (1) ON TOP, (2) PER SIDE. TYPICAL 2"" X 6" FLOOR JOISTS J o USE TP35 FLAT MENDING PLATE I A I I ACH RAF I LN 10 PLATE WITH (6) @ 20" O.C. � o AT (6j PLACES WHERE 2x12 PLATE 12(D) RING SHANK NAILS, (3) EACH SIDE CD MITRES AT CORNERS ON TOP SURFACE OF RAFTER CONNECT RAFTER TO 44 PT 4" X 4" TYP. MAX. 6' O.C. O° POST WITH (1) MTS12 STRAP W/ (2) A35 CLIPS PER POST 4" X 4" TYP. MAX. 6' O.C. �— ------ ----- ------ ---- ----- (3) 2„X8" P.T.RIDGE W/ #8 X 3" SCREWS TYPICAL (3) #80" SCREWS PER (3) @ 12" O.C. PER JOIST END INTO 4"X4" POST 2"x4"TOP OR W/(2)#8x21 SCREWS TO POS- DECORATk MIN. 36" E 4" SPACE MAX. 2" S BOTTOM R 2x2 SPINDLES W/ (1) #8 x 2 1 SCREW TO 2" x 4" RAIL 2"x 6" OUTER TOP FLOOR BAND FASTENED WITH #8 x 2-1/2" SCREWS @ 3" O.C. TO DECKING JED TO SKID WITH HS24 CLIP FLOOJIP-l�F-R'-'A-MtNG PLAN 8'-0" to 24'-0" ELEVATION PLAN 2x6 ANGLE BRACKETS W/ (2) #8 x 2 1/4" SCREWS EACH END d- d - r\ ROOF FRAMING PLAN ROOF SHEATHING, 1"X4" FASTENED WITH #8 x 2" SCREWS(2) PER BOARD END @ 1-1 8" O.C. (SHOWN ON ONE SECTION FOR CLARITY) \ 26 P.T, DECKING W/ (3) #8 x 2 1/2" SCREWS TO JOIST 2X6 GAZEBO IS ATTACHED TO 40 P' W/ (1) A33 CLIP AT (4) PLACE`. PRE MANF. 4"x8"x16" C( OR 2"x8"x16" CONCRETE OR 1"x16"x16" ABS PLAN FOR LEVELING MAX. 36" O.C. AND MAX. 4" FROM PERIMETER FLOOR BEAM MAX. 3" OF WOOD SHIM FOR LEVELING PURPOSE 4-6" CEDAR SHAKE ROOFING WITH (4) 1" CROWN x 1" STAPLE PER SHINGLE CONNECT RAFTER TO 44 PT. POST WITH (1) SIMPSON STRONG TIE MTS12 STRAP 1 "x 6" P i FACIA GENERAL NOTES: 1. ROOF AND FLOOR JOISTS AND ALL FRAMING LUMBER SHALL PRESSURE TREATED #2 SOUTHERN YELLOW PINE .40 2. FLOOR SHEATHING SHALL BE 2x6 PRESSURE TREATED #2 SOUTHERN PINE ANCHORED W/ MIN. (3) #8 x 2 1/2" SCREWS EACH BOARD 3. ALL FASTENERS AND METAL SHALL BE GALVANIZED STEEL 4. OPTION 3 TAB ASPHALT SHINGLES WITH (4) 1 1/4" ROOFING NAILS OR 29 ga. METAL ROOFING WITH #8 x 1 1/2" SCREWS W/ NEOPREME WASHERS @ 12" U.C. AT VETICAL RIDGES ON EACH PANEL 5. BUILDING AND SKIDS AVERAGE 25 PSF DEAD WEIGHT 4" X 4" PT POSTS 8 PLACES W/ 1x4 TRIM 2 FACES W/ MIN. (2) #8 x 2 1/2" WOOD SCREWS (2) 3/8" x 4 1/2" GALVANIZED LAG SCREW WITH 1" WASHERS ATTACHING 16ga 1-3/8" x 8" TO 48" GALVANIZED STRAP TO GAZEBO POST AND OUTER BAND THEN 3/8" GALVANIZED THRU BOLT WITH 1" WASHERS STRAP TO TYPE #30 5/8" DIA. MOBILE HOME TYPE EARTH ANCHOR NOTE: IF ANCHORING TO CONCRETE USE SIMPSON A24 WITH 3/8"x3" EXSPANSION BOLT TO EXISTING 4" 2500 PSI CONCRETE SLAB AND (1) 3/8" THRU BOLT TO ANCHOR STRAP \RIES XISTING GRADE JIN. 20" TYPICAL SECTION VEIW E w > E .s w E S .'� V) C U S N C z o -ac on c -'Ez ' t 0 0 a- (n °' E a o °`' c 0 a o o Q) aL.� v� o E c °+ 3x ami o '� n o > .� L 3 0 c 0 � ; a� U7 s v o v ° .s vOi o CONSTRUCTION TYPE: V -B (OPEN) WIND SPEED = 150 MPH (3 SEC. GUST) WIND IMPORTANCE FACTOR = 0.77 WIND EXPOSURE = CATEGORY C N/A COMPONENTS AND CLADDING ROOF= +28.2 / -94.8 WALL= +49.0 / -65.6 DESIGN REQUIREMENTS LIVE LOADS ROOF = 20 PSF FLOORS= 100 PSF ASSUMED SOIL DENSITY= 2000 PSF NOTE: THIS PROJECT HAS BEEN DESIGNED IN ACCORDANCE WITH 2004 FLORIDA BUILDING CODE and RESIDENTIAL SECTION R301 DESIGN CRITERIA AND ASCE 7-02 TO THE BEST OF MY KNOWLEDGE THESE CONTRACT DOCUMENTS PREPARED UNDER MY DIRECT SUPERVISION, COMPLY WITH THE APPLICABLE MINIMUM CODE REQUIREMENTS AND THE SAFETY STANDARDS AS DETERMINED BY THE LOCAL AUTHORITY IN ACCORDANCE WITH CHAPTERS 553 AND 833 OF THE FLORIDA STATUTES. _ drawn 7 RAG job no. 3427 opt zogj, 1 yow 11,11 AV IN I I�K Enos CD Ali ZONE �7 Eno A IZQREV9 SPARE U a you k QO -way A KWIC pill iwin ............ . . . . . i -to 777 I,V,j :01 IWoo, too A two logo ANT No I= if IWin f NSI: evil qy; Not 0MY, �OK 12t, Iq P A ag: In? ........... . QWM Loon, is pool W Wwass 1 N K I Liu ism AZT! zo Vol Ino -A RAO' K my INV. pit SIMIN 1 ,40f- lag UR Le P Ipoll! CEO, IF .......... VA: too; Ahdo� lI RECEIVED , c� JAN 3 1 E 2006 REVISIONS PERMIT #b(o9 GJ DATE l 13to ADDRESS CONTRACTOR�E �vo�S�`Zyc�'rc-til P H # (L�"c)-I) 32-3 �, �S FAX # 3 2-39 3 of f DESCPRITION OF REVISION; I'o0fZ.0 Ct+vi��� UTILITIES FIRE BLDG ' 272'-0" 25-0" I 25—O" 25-0" 1 25-0" 25-0' 22'—O" 25-0' 25-0" 25-0' 25-0" 25-0" we 4- 5-2 5-2 4 - r- -I - r --- ---------I r-----------� r-------- ----I - r- -------- --� r- -------- --� --------- - i I --------- T r - ---------I r- -------- --� T r- -------- -I -------- - ��t I ��-®------ -------------- s -//---�� I F2 I F2 I / F2 I F2 I F2 I F2 I F2 I F2 I F� %1001F2 e F2 0F=2 ! ` e - - //� - - - ` - - ``` / I L� r -I F F1 F1 I I I I I I I I I I I I I I I I I I I I I 3 S-2 3 52 I ,III @JOI T5 1 I - O O L F1 - I rJ / F3 / \ F3 r�_ r / F2 — — �F` DF2 I I I I F2 I I I r2 I /ills I J I F2 ` I I / / F1 I� - - F1 - F1IF1F1 - - F1 I - - Fr`-+ — ` 4_6 I I I I r- Y I I -� I I r I Iv I�I I y----- ---J-J L ------J d:! L- -----J - L• —J `�' L — -1 �----- --� I---- -- --J f LJ L--- --- --J — -- ----� "' L ----J L --1 L — J = L ---- —J V L ------U L- --I L-- ----- —J n ------ ----- -----� E-2 5-2 Fl F1 5 6 w "A SCALE: 3/32" =1'-O" FOOTING SCHEDULE MARI< SIZE REINFORCEMENT PERMIT SET 26 JAN. 2006 REV. #1 PEMB DWG REVIEW S LENGTH WIDTH DEPTH TOP CENTER BOTTOM REMARKS O5-0" LAYER MANAGER: 5-0" 1'-10" - - (3) # 5 BARS E.W. SEE DETAIL 4/5-2 F2 5'-0" 5'-0" 1'-10" - - (0) #5 BARS E.W. SEE DETAIL 4/5-2 F3 0-0" 0-0" 2-0" - - (7) #5 5AR5 E.W. 5EE DETAIL 4/5-2 1. THE BOTTOM OF ALL FOOTINGS SHALL BE (1'-0") MIN. BELOW FINISHED EARTH GRADE. FLOOR SLAB: 4" CONCRETE SLAB (Fc 3,000 PSI MIN.) WITH 0 X ro 10/10 WIRE MESH ON ro MIL VAPOR BARRIER ON TERMITE TREATED COMPAGTED SUBGRADE CONTRACTOR'S OPTION: FIBER MESH MAY BE USED IN LIEU OF WELDED WIRE MESH. CONCRETE SUPPLIER SHALL PROVIDE SUBMITTALS FOR THE ENGINEER TO REVIEW SHOWING AN APPROPRIATE DOSAGE OF FIBER MESH WHICH MEETS OR EXCEEDS THE FLEXURAL STRENGTH OF THE WELDED WIRE MESH. NORTH CONTRACTOR NOTE CONTRACTOR SHALL USE METAL BUILDING MANUFACTURER'S PLANS FOR COLUMN AND ANCHOR BOLT PLACEMENT. SEE DETAIL 5/5-2 FOR ANCHOR BOLT SIZES. ❑0 0 2 7 2006 7AVID -1. 5CIONACHER, P.E. FLORIDA EG. # 03131 (NOT VALID WITHOUT SEAL) CONSTRUCTION CO. GENERAL CONTRACTORS 790 MONROE RD. SANFORD, FL 32771 PH 407 3231150 FX 407 323 9304 EMAIL: drodd1@mckeeconstructionco.com Florida License CBC 048972 AVANTI GROUP PROJECT #: 05-015 THE AVANTI GROUP, INC. ENGINEERS ® PLANNERS ® DEVELOPERS 10306 Woodberry Rd., Tampa, Florida 3361-9 Phone: (813) 655-2884 Fax: (813) 655-288ro EMAIL: dechonocher@tompoboy.rr.com OB+ARCHITECTURE INC 100 EAST PINE STREET, SUITE 201 ORLANDO, FLORIDA 32801 PH: 407.650.3735 FAX: 407.650.3736 FLORIDA LICENSE NUMBER AR0017725 REVISIONS Et SUBMISSIONS DATE DESCRIPTION 14 OCTOBER 2005 PERMIT SET 26 JAN. 2006 REV. #1 PEMB DWG REVIEW PROJECT LOEt TS N'0% wft 0 UK - i = H SEMINOLE BUSINESS C 3991 W 1 ST STREET STATE ROAD 46 - SANFORD, FLORIDA 32771 SHEET TITLE F E Is 00"'UNDATION PLAN Et SCHEDULES PROJECT NO: AD -2005-12 SHEET NUMBER DRAWN: KRM CHECKED: DMS LAYER MANAGER: SHEET SET: PRINT DATE: OCTOBER 14, 2005