Loading...
105 Central Park Pl - BC05-003936 (INTERIOR - BATHROOM ADDITION) (FIRE) (A)PERMIT ADDRESS CONTRACTOR ADDRESS Conrad Construction, Inc 511 Central Park Dr. Sanford, FL 32771 CBC058118 PHONE NUMBER_ 407-330-3238 PROPERTY OWNE" ADDRESS Parktee Management Corp. 111 Central Park Dr. Sanford, FL 32771 PHONE NUMBER_ ELECTRICAL CONTRACTOR MECHANICAL CONTRACTO PLUMBING CONTRACTOR MISCELLANEOUS CONTRACTOR PERMIT NUMBER FEE MISCELLANEOUS CONTRACTOR PERMIT NUMBER FEE SUBDIVISION PERMIT # Off` J� DATE PERMIT DESCRIPTION PERMIT VALUATION 1 0( 006 SQUARE FOOTAGE ct S e TO SYSTEM - ELEV. 17'-0!I' 6' ELECT. BELL 0 WATERFLOW SWITCH GAUGE ASSEMBLY : _ HYDRAULIC PLACARD 2' o 2' ANGLE VALVE 0'-4 � HD CABINET 00 � 6 & WRENCH (U - ELEV. 2'-4 N I 4' I.B.R. 2' x 2'-0 W/ 45' U Riser Detail No Scale -WET 1 :Inspectors Test Conn. Detail No Scale B.O.P. 20'-0 - EXTERIOR WALL x NORTH NOTE: ALL DROPS TO BE I'x24W/ V x V R.C, Fire Sprinkler Piping Plan TOTAL AREA 34,560 SQ FT. 12' Building Section No Scale SCALE 3/32'=1'-0' INC ATR HANGER RING S,I,N, R3615 S,I.N, TY6137 1/2"2(5.6K) /4"1(114.OK 155' QR 200 SR RELIABLE F1 FR ai TYCO EC -14 CHRM PEND BRASS UPR SEMI-REC NO ESC QUICK RESPONSE STANDARD RESPONSE STANDARD SPRAY EXT, COVERAGE ImZ�:r Hanger Detail >IDEWINDER INC ATR HANGER RING No Scale SEE SITE PLAN FOR CONT, -zo ;011 01 IL r" General Notes: 1. Design Criteria: Wet pipe system of automatic sprinklers hydraulically designed to provide .20 gpm/sq ft throughout the warehouse area and .10 gpm/sq ft in the office area. All sprinkler head spacing and locations to comply with NFPA 13, 1999 edition and the manufacturers specifications. 2. All roll grooved piping sizes 2" thru 4" to be Sch. 7 black steel, all threaded piping 1" thru 1-1/4" to be Sch, 40 black steel. All fittings to be mechanical roll grooved or cast iron threaded. 3. All material, devices and installation to comply with NFPA 13, 1999 edition, and The City of Sanford. 4. All overhead piping to be hung with U.L. listed hangers properly spaced in accordance with NFPA 13, 1999 edition. 5. All piping to be hydrostatically tested at 200 psi for (2) hours. All underground piping to be flushed before any overhead piping is tied in. 6. All firewall penetrations to be sealed in accordance with their rating. � 2f 0 00 " a U 'Ln �ZWr� U 1 1 H W¢��(y) C:]��-Q�`° a _j co W L,.., 0 -j (tJ I c� co J U L'- I CL I LLQ(YQo� Zf-<0't E3ZZa 0 QW3wIt W U 077 W oZE3x G�LL_ MOT¢ LL_ O.-,JWL.- �_Vx n Fire Sprinkler Piping Plan CONTRACT # COMM, DRAWN ; B,A.J. CHECKED ; J.C. DATE ; 10-19-04 TOTAL HEADS :156 SCALE ; AS NOTED FP -2 SHEET 2 OF 2 ai ai z ID Z P- Q ¢ 0 ¢ H W Q Zry (] 0 � ¢ ¢ J Q �- V Z p H > W '- W � 3 W Z W 0 ,CD 0 In I- Q 01 I 11D I 1 I Z o r, 0_1z 1 CONTRACT # COMM, DRAWN ; B,A.J. CHECKED ; J.C. DATE ; 10-19-04 TOTAL HEADS :156 SCALE ; AS NOTED FP -2 SHEET 2 OF 2 n DOOR SHEDULE 0 TYPE a,"�`je :.«. OCATION A 3068 HOLLOW CORE WOOD INTERIOR B 3068 METAL INTERIOR C 3068 METAL EXTERIOR D 6070 STOREFRONT GLASS EXTERIOR E 10'X 10' OVERHEAD METAL INTERIOR F 14' X 14' OVERHEAD METAL EXTERIOR G 20'X 14' OVERHEAD METAL EXTERIOR H 3068 METAL HALF-LIGHT EXTERIOR I 3068 METAL FULL -LIGHT INTERIOR n PLANS REVIEWED Cj-r'y OF SANFORD