Loading...
124 Commerce Way - BC05-003740 (HUTCHINSON AUTOMOTIVE) (ADDITION) (A)PERMIT ADDRESS CONTRACTOR \ " _\C" ADDRESS c� ((7) PHONE NUMBER L. PROPERTY OWNER \ V ADDRESS PHONE NUMBER ELECTRICAL CONTRACTOR MECHANICAL CONTRACTO PLUMBING CONTRACTOR MISCELLANEOUS CONTRACTOR PERMIT NUMBER FEE MISCELLANEOUS CONTRACTOR PERMIT NUMBER FEE A SUBDIVISION PERMIT # DATE PERMIT DESCRIPTION 1. c PERMIT VALUATION �� V SQUARE FOOTAGE 9 o' 0 b d ,L O EMAIL: drodd1@mckeeconstructionco.com Florida License CBC 048972 By, tev _-T _--- - ��-- 1 OB+ARCHITECTURE INC 100 EAST PINE STREET, SUITE 201 ORLANDO, FLORIDA 32801 PH: 407.650.3735 FAX: 407.650.3736 FLORIDA LICENSE NUMBER AR0017726 REVISIONS & SUBMISSIONS DATE DESCRIPTION 07/21/2005 PERMIT SET PROJECT HUTCHINGS AUTOMOTIVE ADDITION, 124 COMMERCE WAY SANFORD, FLORIDA 32771 SHEET TITLE 0 PLANS REVIEWED r afy of SANFORD PERMIT COVER SHEET PRINT DATE: 07/21/2005 SHEET NUMBER CVR PROJECT NO: AD -2005-23 DRAWN: JLP / SRR CHECKED: RAG LAYER MANAGER: CVR-CODE SHEET SET: CVR-CODE OB+ARCHITECTURE INC 100 EAST PINE STREET, SUITE 201 ORLANDO, FLORIDA 32801 PH: 407.650.3735 FAX: 407.650.3736 FLORIDA LICENSE NUMBER AR0017725 REVISIONS & SUBMISSIONS DATE DESCRIPTION 07/21/2005 PERMIT SET PROJECT HUTCHINGS AUTOMOTIVE ADDITION 124 COMMERCE WAY SANFORD, FLORIDA 32771 SHEET TITLE FLOOR ROOF PLAN PRINT DATE: 07/21/2005 SHEET NUMBER PROJECT NO: AD -2005-23 DRAWN: JLP / SRR CHECKED: RAG LAYER MANAGER: CVR-CODE SHEET SET: CVR-CODE WEATHER STRIP ALUMINUM THRESHOLD HANDICAP ACCESSIBLE SEE DOOR SCHEDULE CONCRETE WALK OR ASPHALT PAVEMENT SLOPE DOWN AWAY FROM BUILDING @ .24" PER FT. x Q MAX. `y SLOPE DOWN e d -4 a a n • EXPANSION MATERIAL SEALANT BED 1/2)) •' 1 • t t t' SCALE: 3" = 1'-0" 3/4" = 1 ' 0" COLUMN PAD) BEYOND SEE FOUNDATION PLAN AND DETAILS SCALE: 3"= 1'-0" IE HEIGHT -4" JM GUTTER \NNEL ,NDARD "R" WALL PANELS JNER SELECTED STD COLOR) JNSPOUT TO GRADE CHANNEL FINISH FLOOR 0'-0" (REFERENCE) J CD T 0� U ERU o PEMB CONT. CAULK c DOOR GUIDES HOLLOW METAL FRAME AND DOOR PEMB SEALANT 3" METAL BUILDING INSULATION WHERE OCCURS METAL BUILDING PANEL GUTTER AND DOWNSPOUTS — 26 GAUGE METAL WALL PANELS 42" HIGH CHAIN LINK GUARD RAIL AT TRUCK WELL RAMP SCALE: 3"= 1'-0" 65"-0" EXISTING BUILDING SCALE: 3"= 1'-0" 1 12 � 1(MATCH `17 — . _ EXISTING SLOPE) ; GUTTER AND DOWNSPOUTS 26 GAUGE METAL WALL PANELS OVERHEAD DOOR 42" H. CHAIN LINK GUARD RAIL DOCK BUMPERS El I SURFACE -MOUNTED EDGE i OF DOCK LEVELER 20'-011 TRUCK WELL - NEW CONSTRUCTION • • L 20'-0" L 65-011 NEW CONSTRUCTION EXISTING BUILDING R ELEVATION (NORTH) (ypR,EEA/8„ = 1,-,-0)) E D C B A OPENING BEYOND 26 GAUGE METAL ROOF SYSTEM GUTTER AND DOWNSPOUTS 26 GAUGE METAL WALL PANELS OVERHEAD DOOR 0 iiii/i//i/ilii/iiiiiiiii/i/i/i////////////////////////////////////////. MCK&D CONS!RUCTION CO. GENERAL CONTRACTORS •1 MONROE 'D SANFORD, PH 407 323 1150 FX 407 323 • 1. ikkuk Florida License CBC 048972 OB+ARCHITECTURE INC 100 EAST PINE STREET, SUITE 201 ORLANDO, FLORIDA 32801 PH: 407.650.3735 FAX: 407.650.3736 FLORIDA LICENSE NUMBER AR0017725 REVISIONS & SUBMISSIONS DATE DESCRIPTION 07/21/2005 . d. F- U) - z V) ww F-- U PROJECT HUTCHINGS AUTOMOTIVE ADDITION 124 COMMERCE WAY SANFORD, FLORIDA 32771 SHEET TITLE EXTERIOR 1LEV WALL SECTION., DETAILS PRINT DATE: 07/21/2005 xw w PROJECT N0: AD -2005-23 DRAWN: JLP / SRR METAL LAYER MANAGER: CVR—CODE SHEET SET: CVR—CODE o' J ---CHANNEL z o Q o s O N Cn Cn SIN w U w EXTERIOR \ T V) T � 3" METAL BUILDING INSULATION METAL BUILDING PANEL OVERHEAD DOOR JAMB SCALE: 3"= 1'-0" 65"-0" EXISTING BUILDING SCALE: 3"= 1'-0" 1 12 � 1(MATCH `17 — . _ EXISTING SLOPE) ; GUTTER AND DOWNSPOUTS 26 GAUGE METAL WALL PANELS OVERHEAD DOOR 42" H. CHAIN LINK GUARD RAIL DOCK BUMPERS El I SURFACE -MOUNTED EDGE i OF DOCK LEVELER 20'-011 TRUCK WELL - NEW CONSTRUCTION • • L 20'-0" L 65-011 NEW CONSTRUCTION EXISTING BUILDING R ELEVATION (NORTH) (ypR,EEA/8„ = 1,-,-0)) E D C B A OPENING BEYOND 26 GAUGE METAL ROOF SYSTEM GUTTER AND DOWNSPOUTS 26 GAUGE METAL WALL PANELS OVERHEAD DOOR 0 iiii/i//i/ilii/iiiiiiiii/i/i/i////////////////////////////////////////. MCK&D CONS!RUCTION CO. GENERAL CONTRACTORS •1 MONROE 'D SANFORD, PH 407 323 1150 FX 407 323 • 1. ikkuk Florida License CBC 048972 OB+ARCHITECTURE INC 100 EAST PINE STREET, SUITE 201 ORLANDO, FLORIDA 32801 PH: 407.650.3735 FAX: 407.650.3736 FLORIDA LICENSE NUMBER AR0017725 REVISIONS & SUBMISSIONS DATE DESCRIPTION 07/21/2005 PERMIT SET PROJECT HUTCHINGS AUTOMOTIVE ADDITION 124 COMMERCE WAY SANFORD, FLORIDA 32771 SHEET TITLE EXTERIOR 1LEV WALL SECTION., DETAILS PRINT DATE: 07/21/2005 SHEET NUMBER A3*1 PROJECT N0: AD -2005-23 DRAWN: JLP / SRR CHECKED: RAG LAYER MANAGER: CVR—CODE SHEET SET: CVR—CODE i-\ ELEV. SEE ARC14. DWG'S. GIRT BY METAL BLDG. SUPPLIER PRE -FINISHED METAL WALL PANEL BY MTL BLDG. SUPPLIER SEE ARCH. DWG'S. /II x x x x 'v =JII 1=Illllillllll LI�III�I u ' 3' CLR SECTION 1 SCALE :3/4" = I'-0" 5-I STEEL COL. 4 BASE PLATE BY PF„- METAL 05 NAI SEE P ELEV. 0'-0' (2) #5 16'x16' SEE FOOTING SCHEDU�-F—'\ FOR 51ZE 4 REINFORCING - CENTER FTG. ON PIER (TYP.) OgL ELEV. 20'-0" �4 FOOTING SCHEDULE MARK 51ZE DEPTH REINFORCING BOTT. BARS REMARK5 UPI 1'-/o"xCONT. 1'-8" (2) #5 T/FTG. 0' -ID" SAME AS FIN. FLOOR WF2 2'-S'xCONT. 1'-0" --------- T/FTG.(-) 4'-0" SEE SEC. 4/5I FOR FTG. DIM., REBARS AND OTHER DETAILS WF3 2'-5"xCONT. 1'-011 --------- PROJECT HUTCHINGS AUTOMOTIVE ADDITION COMMERCE WAY SANFORD, FLORIDA 32771 O PRINT DATE: 07/13/2005 SHEET NUMBER S-1 PROJECT NO: AD -2005-23 DRAWN: MD / SRR r LAYER MANAGER: CVR—CODE SHEET SET: CVR—CODE F1 3'40"x3'40" 1'-5" (4) S EACH WAY T/FTG. m' -m" F2 41-011x4'-0" 1'-S" (5) S EACH WAY T/FTG. O' -fall F3 3'40"x3'40" 1'-0" (4) S EACH WAY T/FTG.(-) 4'-5" WALL ot ELEV. SEE ARCH. DWG': 1/51 CONT. GIRT 15Y METAL BL 'GN. DLZS. FOR sum DETAILS (TYP.) PRE-FINV METAL WALL F BY MTL BLDG. SUFE SEE ARCH. G I . Y"HENT OR GRADE -SEE CIVIL DRAWINGS -I I II T II II„1111111111111111 11-1 �I I � I I � I-,1 11=III—� � �—I I I=1 I �, ;, I S I 1 U SEE FOUNDATION PLAN 5E CT I Oil 2 SCALE : 3/4” = 1'-0" S-1 PILASTER PI 16'X16' PILASTER BLOCK W/4 +'5 VERT BARS 03 TIES is 12"O.C. �r- I SIL- SGALE 3/4' = 1'-0' 5E CT I ON 3 �, SCALE : 3/4" - 1'-0" S -I EXISTING CONSTRUCTION EXISTING BLDG, FIN. FLOOR ELEV. 0'-0' (ASSUMED) TYP. 4' CONC. SLAB REIN W/ 6x6 W1.4xWIA W.WF. ON 6 MIL VISQUEEN ON COMPACTED TREATED FILL. TOP ELEV. 0'-0' (TYPJ (UN.O.). SEI= CIVIL SITE PLAN OR ARCH. DU1G'S. FOR ACTUAL ELEVATIONS. MATCH EXISTING SLAB ELEV. / (4)- I'-0' FOOTING. STEPS 2'-0' APART 0 I e p CV / O I CV CV 0 Pl _ 16' x 16' PILASTER TOP OF FOOTING AT STEM WALL -4'-8' 20'-0" W1=1 FI C,) — � EXPANSION JOINT MATERIAL ,=1\ —7F2 F1 F2 (2) #5x6'-6' HAIRPIN BARS TYP. ( EACH LECs ) CJ IW CAJ F2.�, T.O. SLAB CJ O I IF3 WF2 I-I XF- C14 TA. SLAB N L I ;-� CV I 0 I irk CV 0 CD I rn C 31 0 I LO CV c� 4 5-I (4)- 1'-0' FOOTIidCs. STEPS 2'-0' APART ' FT"TEP SUMP PIT SEE ARCH. DWGS EXISTING PAVEMENT SEE ARCH. OR CIVIL SITE PLAN B, TRUCK WELL ELEV. 0'-0' FIN. GRADE MOND BEAM TYR. LOCK o 0 I LO STEM WALL TO BE 0 1=1 GROUTED SOLID -III S • 2'-0' O.C. VERT. BARS LAP 2'-8' =1 0 IF SAPERATE DOWELS USED '¢ TYP. 09 GAGE LADER TYPE JOINT 1i' EXP. JOINT U REINF. (DURAWALL JOINT REINF-) MATERIAL AT 16 1 O.C. 5' TRUCK WELL SLAB W/ 03 BAR AT 12' O.C. PROJECT EXISTING BLDG. 8' CMU WALL EACH WAY At CENTER } SLAB EDGE / FOUNDATION WITH m U WALL OF SLAB PRACED EXCAVATION, US1NG SHEET PILING OR SIMILER MEANS. V-4.1 g■ SUBMIT PILING SCHEME TO ARCH +4 a 16' O. ENGINEER FOR THEIR REVIEW TOP BARS (2) 45 BARS him 04 a 12' O.C. U 0 1I -11 FOUNDATION PLAN SEAL 3" CL. 3 45 SCALE : 3/4".1'-0" MKT ENGINEERS STRUCTURAL ENGINEERS ENGINEERING BUSINESS #26349 (4) 05 BARB .-vii ,7 2265 LEE ROAD. SUITE 123 SECTION 4 �/ `" WINTER PARK, FL. 32789 TEL. - SCALE :'/4" = 1'-0" S-1 (407) 628 8555 KISHORE D. TOLIA FAX (407) 644-6516 PHMSMN" NNGRUM No. 15022 MKT P R O D. No. 05333 STATE CE FLORIDA OB+ARCHITECTURE INC 100 EAST PINE STREET, SUITE 201 ORLANDO, FLORIDA 32801 PH: 407.650.3735 FAX: 407.650.3736 FLORIDA LICENSE NUMBER AR0017725 REVISIONS & SUBMISSIONS DATE DESCRIPTION 07/13/2005 0 I cV p a PROJECT HUTCHINGS AUTOMOTIVE ADDITION COMMERCE WAY SANFORD, FLORIDA 32771 O PRINT DATE: 07/13/2005 SHEET NUMBER S-1 PROJECT NO: AD -2005-23 DRAWN: MD / SRR r c� 4 5-I (4)- 1'-0' FOOTIidCs. STEPS 2'-0' APART ' FT"TEP SUMP PIT SEE ARCH. DWGS EXISTING PAVEMENT SEE ARCH. OR CIVIL SITE PLAN B, TRUCK WELL ELEV. 0'-0' FIN. GRADE MOND BEAM TYR. LOCK o 0 I LO STEM WALL TO BE 0 1=1 GROUTED SOLID -III S • 2'-0' O.C. VERT. BARS LAP 2'-8' =1 0 IF SAPERATE DOWELS USED '¢ TYP. 09 GAGE LADER TYPE JOINT 1i' EXP. JOINT U REINF. (DURAWALL JOINT REINF-) MATERIAL AT 16 1 O.C. 5' TRUCK WELL SLAB W/ 03 BAR AT 12' O.C. PROJECT EXISTING BLDG. 8' CMU WALL EACH WAY At CENTER } SLAB EDGE / FOUNDATION WITH m U WALL OF SLAB PRACED EXCAVATION, US1NG SHEET PILING OR SIMILER MEANS. V-4.1 g■ SUBMIT PILING SCHEME TO ARCH +4 a 16' O. ENGINEER FOR THEIR REVIEW TOP BARS (2) 45 BARS him 04 a 12' O.C. U 0 1I -11 FOUNDATION PLAN SEAL 3" CL. 3 45 SCALE : 3/4".1'-0" MKT ENGINEERS STRUCTURAL ENGINEERS ENGINEERING BUSINESS #26349 (4) 05 BARB .-vii ,7 2265 LEE ROAD. SUITE 123 SECTION 4 �/ `" WINTER PARK, FL. 32789 TEL. - SCALE :'/4" = 1'-0" S-1 (407) 628 8555 KISHORE D. TOLIA FAX (407) 644-6516 PHMSMN" NNGRUM No. 15022 MKT P R O D. No. 05333 STATE CE FLORIDA OB+ARCHITECTURE INC 100 EAST PINE STREET, SUITE 201 ORLANDO, FLORIDA 32801 PH: 407.650.3735 FAX: 407.650.3736 FLORIDA LICENSE NUMBER AR0017725 REVISIONS & SUBMISSIONS DATE DESCRIPTION 07/13/2005 PROGRESS SET PROJECT HUTCHINGS AUTOMOTIVE ADDITION COMMERCE WAY SANFORD, FLORIDA 32771 SHEET TITLE FOUNDATION PLAN DETAILS PRINT DATE: 07/13/2005 SHEET NUMBER S-1 PROJECT NO: AD -2005-23 DRAWN: MD / SRR CHECKED: KDT LAYER MANAGER: CVR—CODE SHEET SET: CVR—CODE 45 a 2'-0' Ox TYP. n GAGE LADER TYP REINF. (DURAWALL JOINT At 8' 1.i1 •4a16'O TOP BAf (2) 45 BAF 04 w 12' O. — CONC. DRIVE SEE ARCH.OR CIVIL ENGINEERING DWGS SEE 3/S1 FOR FOOTING DIM. AND RENFORCEMENT. CORNER TYPICAL DETAIL OF SPLICES FOR HORIZONTAL REINFORCEMENT AT ALL CORNERS AND INTERSECTIONS OF ALL FOOTINGS, THICKENED SLABS ON GRADE, WALLS, BEAMS, AND CONTNUOUS KNOCK -OUT BLOCKS UNLESS OTHERWISE INDICATED. TYPICAL CORNER 5AfR DETAIL SCALE: 3/4'm1'-0 4 U , t FIN. FLOOR ELEV. lo 21-0@ 3- 0 5 x 3-9" At T -b" EA. STEP (TYPJ I1'-3" � •4 U 3' CL• 10'-0' 10'-0" 10'-0" 10'-0' 10'-0" N Q m 2,_8, (4)15 BAR tu C1 3- • 5 At EA. 5E CT I ON 1 STEP (tYP.) SCALE : 3/4" = 1'-0" S-2 / 1- 4 (EA. STEP) TYP. II II GENERAL ALL DETAILS AND SECTIONS SHOWN ON THE DRAWING5 ARE INTENDED TO BE TYPICAL AND SHALL BE CONSTRUED TO APPLY TO ANY SIMILAR SITUATION ELSEWHERE ON THE PROJECT, EXCEPT WHERE A DIFFERENT DETAIL IS SHOWN. SHOP DRAWINGS IN THE FORM OF REPRODUCIBLE SEPIAS OF ARCHITECTURAL OR STRUCTURAL DRAWINGS (CONTRACT DOCUMENTS) ARE PROHIBITED WITHOUT EXPRESS WRITTEN PERMISSION FROM ARCHITECT/ENGINEER. ALL SUBMITTALS SHALL HAVE 1 REPRODUCIBLE SEPIA AND 2 BLUELINE PRINTS AND ADDITIONAL PRINTS SUBMITTED SHALL DISCARDED. MANUFACTURERS OF ANY PRE-ENGINEERED, PRE -FABRICATED SYSTEM OR COMPONENT SHALL SUBMIT SHOP DRAWINGS FOR THE ENGINEER/ARCHITECT'S APPROVAL PRIOR TO FABRICATION OR ERECTION OF SYSTEM/COMPONENT. THESE SHOP DRAWINGS SHALL BE SIGNED AND SEALED BY A FLORIDA REGISTERED ENGINEER THE BUILDING IS DESIGNED IN ACCORDANCE WITH 2001 EDITION OF: FLORIDA BUILDING CODE. FOLLOW ALL APPLICABLE PROVISIONS FOR ALL PHASES OF CONSTRUCTION. THE STRUCTURAL INTEGRITY OF THE COMPLETED STRUCTURE DEPENDS UPON THE INTERACTION OF VARIOUS CONNECTED COMPONENTS. PROVIDE ADEQUATE BRACING, SHORING, AND OTHER TEMPORARY SUPPORTS AS REQUIRED TO SAFELY COMPLETE THE WORK. FOUNDATIONS: GEOTECHNICAL ENGINEERING EVALUATION AND SUBSURFACE EXPLORATION WILL BE PERFORMED BY OWNER'S CONSULTANT. THEIR RECOMENDATIONS WILL BE MADE PART OF CONTRACT DOCUMENTS. FOLLOW ALL REQUIREMENTS AND RECOMMENDATIONS. MAXIMUM ALLOWABLE SOIL PRESSURE IS ASSUMED TO BE 2000 POUNDS PER SQUARE FOOT. IT SHALL BE OWNER'S RESPONSIBILITY TO VERIFY ALLOWABLE SOIL PRESSURE'S SPREAD FOOTINGS SHALL BEAR ON SOIL COMPACTED TO A DEN51ITY OF AT LEAST 95% OF MODIFIED PROCTOR MAXIMUM DENSITY (A.S.TM. D1551). THE SOIL SHALL BE COMPACTED TO THIS DENSITY TO A DEPTH OF AT LEAST TWO FEET BELOW THE BOTTOM OF THE FOOTINGS, AND ALL FILL MATERIAL NECESSARY TO ACHIVEPROPER SLIBGRADE LEVEL. FILL UNDER FLOOR SLABS SHALL BE COMPACTED TO A DENSITY OF AT LEAST 95% OF MODIFIED PROCTOR MAXIMUM DENSITY (A.S.T.M. D1551), AT LEAST 1"-0' BELOW FIN16HED FLOOR ABOVE COMPACTION REQUIREMENTS ARE MINIMUM. USE PRPER EQUPMENT SO AS NOT DAMAGE EXISTING BUILDING. CONCRETE: DESIGN OF REINFORCED CONCRETE CONFORMS WITH BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE - ACI 318, LATEST EDITION. CONCRETE WORK SHALL BE PER ACI 301 (LATEST EDITION) SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR BUILDINGS. ALL CONCRETE FOR FOUNDATIONS, SLAB ON GRADE, AND CMU FILLED CELLS, IF ANY SHALL HAVE AN UNCONFINED COMPRESSIVE STRENGTH OF 3000 PSI AT 28 DAYS. CONCRETE FOR TILT PANELS SHALL BE 4000 PSI AT 28 DAYS. GENERAL CONTRACTOR SHALL CHECK ARCHITECTURAL, MECHANICAL AND ELECTRICAL DRAWINGS FOR OPENINGS, SLEEVES, ANCHORS, HANGERS, SLAB DEPRESSIONS AND ANY OTHER ITEMS RELATED TO CONCRETE WORK, AND SHALL ASSUME FULL RESPONSIBILITY FOR THEIR PROPER LOCATION, BEFORE POURING CONCRETE. AT OPENINGS IN SLABS OR WALLS, PROVIDE 2 - 06 15AR5 EACH 6"-0" LONGER THAN WIDTH OF OPENING ON EACH OF 4 SIDES OF OPENINGS, UNLESS SHOWN OTHERWISE. PITCH CONCRETE SLABS, WHERE REQUIRED, TO FLOOR DRAINS SHOWN ON THE ARCHITECTURAL AND MECHANICAL DRAWINGS. CONCRETE PROTECTION FOR REINFORCING BARS SHALL BE AS FOLLOWS: FOOTINGS 3" CLEAR, BOTTOM AND SIDES, 2" CLEAR, TOP WALLS 2" CLEAR, OUTSIDE FACE, 1-1/2" CLEAR, INSIDE FACE UNO 5LA55 3/4" CLEAR, 1-1/2" CLEAR AT AREAS EXPOSED TO WEATHER. BEAMS 1-1/2" CLEAR TO STIRRUPS COLUMNS 1-1/2" CLEAR TO TIES DESIGN MIXES: SUBMIT MIX DESIGN PREPARED BY A CERTIFIED LAB WHO IS DIFFERENT THAN ONE CONDUCTING SLUMP TESTS AND CYLINDER BREAKS. LABEL EACH MIX DE51GN TO INDICATE THE AREA IN WHICH THE CONCRETE 15 TO BE PLACED. MIX DESIGN SHALL BE PER EITHER METHOD I OR METHOD 2 OIF ACI 301. PROVIDE SUPPORTING DATA FOR EACH MIX DESIGN. PROVIDE NORMAL WEIGHT CONCRETE WITH THE FOLLOWING PROPERTIES: 28 DAY COMPRE551VE STRENGTH AS SPECIFIED ABOVE, USE TYPE I PORTLAND CEMENT. NO FLY ASH OR OTHER POZZOLAN IS PERMITTED. SUMP LIMIT 3" TO 5'. AIR CONTENT 2 TO 4%. REINFORCING STEEL: REINFORCING STEEL SHALL BE NEW BILLET STEEL CONFORMING TO A.S.T.M. A6 15 -GRADE (00, EXCEPT THAT NEW BILLET STEEL CONFORMING TO A.S.T.M. 4615 -GRADE 40 MAY BE USED FOR COLUMN TIES AND BEAM STIRRUPS. ALL DETAILING AND ACGESSORIES SHALL CONFORM TO TYPICAL DETAILS SHOWN IN THE "MANUAL OF STANDARD PRACTICE FOR [DETAILING REINFORCED CONCRETE STRUCTURES ACI 315, LATEST EDITION". ALL CONTINUOUS VERTICAL OR HORIZONTAL BARS IN FOOTINGS, FOUNDATIONS WALLS, SLABS AND OTHER CONCRETE SHALL BE LAP -SPLICED, WHERE NEGESSARY OR DESIRABLE, BY WIRING TOGETHER IN CONTACT. LENGTH OF ALL LAPS SHALL BE 40 -BAR DIAMETERS OR 2'-8" MINIMUM, WHICHEVER IS GREATER (EXCEPT AS NOTED BY DRAWINGS). ALL BARS AT END OF CONTINUOUS FOOTINGS OR BEAMS SHALL BE DONT. TO FAR SIDES OF INTERSECTING ELEMENTS. ALL SLABS ON GRADE SHALL BE 4" THICK AND REINFORCED WITH 6 x 6 - WIA x WIA W.W.F. UNLESS OTHERWISE NOTED. LAP FABRIC S" AT EDGES AND ENDS AND PROVIDE ADDITIONAL REINFORCING WHERE SHOWN ON DRAWINGS. PLACE MESH IN CENTER OF SLAB. USE SLAB BOLSTER AND WIRE TIES TO KEEP FABRIC IN PLACE DURING CONCRETE POUR LIFTING OF WWF WHILE CONCRETE IS BEING POURED IS NOT ACCEPTABLE. MOISTURE BARRIER BENEATH FLOOR SLABS SHALL BE 6 MIL POLYETHYLENE. USE FLAT SHEETS OF WELDED WIRE FABRIC. ROLLS WILL NOT BE PERMITTED. STRUCTURAL STEEL: (IF ANY) FABRICATION AND ERECTION OF STRUCTURAL STEEL SHALL BE IN ACCORDANCE WITH A.I.S.C. "SPECIFICATIONS FOR DESIGN, FABRICATION AND ERECTION OF STRUCTURAL STEEL FOR BUILDING", LATEST EDITION. ALL STRUCTURAL STEEL SHALL MEET THE REQUIREMENTS OF A.S.T.M. A-36, EXCEPT STRUCTURAL STEEL TUBE SHAPES SHALL MEET THE REQUIREMENTS OF A.S.T.M. A500, GRADE B. ALL STEEL PIPE SHALL MEET THE REQUIREMENTS OF ASTM A53 E OR S, GRADE B. ALL WELDED CONNECTIONS SHALL BE DESIGNED TO BE FULLY EQUIVALENT IN STRENGTH TO BOLTED CONNECTIONS FOR THE SAME SIZE BEAM. ALL WELDS FOR COLUMN GAP AND BASE PLATES SHALL BE CONTINUOUS 1/4" FILLET WELDS, UNLESS SHOWN OTHERWISE. ALL WELDING SHALL BE DONE BY CERTIFIED WELDERS IN ACCORDANCE WITH AWS "CODE FOR ARC AND GAS WELDING IN BUILDING CONSTRUCTION", LATEST EDITION. USE E10 -XX ELECTRODES FOR ALL WELDING. PROVIDE ALL STRUCTURAL STEEL LINTELS, SHELF ANGLES, AND ALL OTHER ROLLED SHAPES SHOWN ON ARCHITECTURAL DRAWINGS. CONCRETE MASONRY: ALL CONCRETE MASONRY CONSTRUCTION SHALL CONFORM TO THE REQUIREMENTS OF ACI -ASCE BUILDING CODE REQUIREMENTS FOR MASONRY STRUCTURES (ACI -ASCE 530) ALL MASONRY CONSTRUCTION MATERIALS AND INSPECTIONS SHALL CONFORM TO ALL REQUIREMENTS OF SPECIFICATIONS FOR MASONRY STRUCTURES (ACI -ASCE 530.1) UNLESS OTHERWISE NOTED. CONCRETE MASONRY UNITS SHALL CONFORM TO ASTM C-90. ALL CONCRETE BLOCKS SHALL HAVE AN ULTIMATE NET COMPRESSIVE STRENGTH OF 2000 P51 MINIMUM TO GIVE A MINIMUM COMPRESSIVE STRENGTH OF MA50NRY ASSEMBLAGE (f'm) OF 1500 PSI, UNLESS NOTED OTHERWISE. MASONRY UNITS SHALL BE LAID IN RUNNING BOND. MORTAR SHALL BE ASTM C-270, TYPE "S" FRESHLY PREPARED AND UNIFORMLY MIXED WITH MINIMUM COMPRESSIVE STRENGTH OF 1800 PSI 10 28 DAYS. ALL CMU CROSS WEBS SHALL BE FULLY BEDDED IN MORTAR AROUND CELLS TO BE GROUTED. GROUT USED IN CONCRETE BLOCKS SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 3000 PSI Q 28 DAYS. GROUT SLUMP SHALL BE 8". GROUT MAY BE POURED OR PUMPED IN LIFTS NOT TO EXCEED 6'-0" MAXIMUM HEIGHT OF GROUT POUR SHALL BE 4'-0" UNLE55 CLEAN OUT OPENINGS ARE PROVIDED AT THE BOTTOM OF CELLS TO BE FILLED. ALL GROUT SHALL BE PUDDLED WITH GROUT STICK IMMEDIATELY AFTER POURING. ALL CELLS CONTAINING REINFORCING STEEL SHALL BE FILLED WITH CONCRETE GROUT. CONTINUOUS INSPECTION 15 REQUIRED FOR ALL MASONRY WALL CONSTRUCTION. PROVIDE CLEAN OUT OPENINGS AT BOT. OF EACH CELLS FOR INSPECTION AS NOTED ABOVE. PURLIN PER BLDG. SUPPLIER ROOF HUNG UNI G, CONT. FOOTIWA _ SEE FOUNDATION PLAN. TYPICAL 5TEP FOOTING DETAIL SCALE : 3,4"=1'-0" :ZE-N..Bog___T_r_ �IN.a n 1 i.-rrvri %~ [IV v_1 ra 1w rq 1 4'-0" O.C. MAX. ADD SANTE DEPTH C-PURLIN AT EA. ROD UNISTRUT OR C8x2.5 16 GAGE PURL IN TYPICAL DETAIL AT ROOF HUNG EQUIPMENT SCALE :3/4" = 1'-0" SEE MECHANICAL DWG'S. SAWCUTS TO BE MADE WITHIN 4 TO 24 HOURS OF POUR W.Wp. —1 '/s" x 1" DEEP SAW CUT Z4 '--VAPOR BARRIER TYPICAL FLOOR CONTROL JOINT DETAIL PRE-ENGINEERED METAL BUILDING FRAME: INDICATED AS CA ON FLOOR PLAN SINGLE SPAN RIGID FRAME BUILDINGS ARE TO BE DESIGNED AND MANUFACTURED BY METAL BUILDING SUPPLIER SEE ARCHITECTURAL AND STRUCTURAL DRAWINGS FOR COLUMN BAY SPACES, SAVE HEIGHT, ROOF PANELS GIRTS AND RELATED ACCE50RIE5. SUBMIT SHOP DRAWINGS AND DESIGN CALCULATIONS SIGNED AND SEALED BY FLORIDA REGISTERED ENGINEER FOR ARCHITECT/ENGINEERS REVIEW PRIOR TO FABRICATION SHOW ALL FOUNDATION REACTIONS ON PLANS. THIS MUST BE AT APPROPRIATE TIME 50 THAT FOUNDATION WORK IS NOT DELAYED. FOLLOW FLORIDA BUILDING CODE FOR LOAD REQUIREMENTS AND FOLLOW M.B.M.A.'S RECOMMENDED DESIGN PRACTICE MANUAL. IN ADDITION TO STRENGTH REQUIRMENTS SERVICEABILITY CONDITIONS (DEFLECTION REQUIREMENTS) AS SPECIFIED BY STANDARD BUILDING CODE SHALL ALSO BE SATISFIED ALL WIND LOADS SHALL BE RESISTED BY METAL BUILDING FRAME. TRANSFERED FROM TILT PANELS AND METAL STUD WALLS TO METAL BUILDING FRAME. ALL STRUCTURAL COMPONENTS SHALL MEET DESIGN CRITERIA SET FORTH IN FBG CHAPTER 16 ALL DOORS, WINDOWS, 4 GLAZING FRAMING SHALL BE ABLE TO WITHSTAND WIND PRESSURE FOR COMPONENTS AND CLADING PER FBG CODE CHAPTER 16 SEE ARCH DWGS FOR SIZES AND LOCATIONS. AND WIND PRE8URE5 DESIGN LOADS: LIVE LOADS: ROOF: 20 PSF WIND LOADS: VELOCITY: 120 MPH IMPORTANCE FACTOR 1.0 EXPOSURE B HEIGHT: 30'-0" "x 2� ICISHORE D. TOLIA PROFV=ML ENGaOM No. LON2 ,,_STATF OF F"LORIlIA MKT ENGINEERS STRUCTURAL ENGINEERS ENGINEERING BUSINESS #26349 2265 LEE ROAD. SUITE 123 WINTER PARK, FL. 32789 TEL. (407) 628-8555 FAX (407) 644-6516 MKT PROD. No. 05333 OB+ARCHITECTURE INC 100 EAST PINE STREET, SUITE 201 ORLANDO, FLORIDA 32801 PH: 407.650.3735 FAX: 407.650.3736 FLORIDA LICENSE NUMBER AR0017725 REVISIONS & SUBMISSIONS DATE DESCRIPTION 07/13/2005 PROGRESS SET PROJECT HUTCHINGS AUTOMOTIVE ADDITION COMMERCE WAY SANFORD, FLORIDA 32771 SHEET TITLE GEN NOTES Et DETAIL PRINT DATE: 07/13/2005 SHEET NUMBER S-2 PROJECT NO: AD -2005-23 DRAWN: JLP / SRR CHECKED: RAG LAYER MANAGER: CVR-CODE SHEET SET: CVR-CODE ACADEMY MANOR - UNIT ONE PLAT BOOK 13, PAGE 93 S89°36'40"W ------------------- FENCE 1.8'W x 0.9's I x FND NAIL NO I.D. x Cf) 0 Ox (v CA 01 150.00'(D&C) FENCE 0.4'W 0.9'S 0 O N CA 11 0 4 REMAINDER OF ACADEMY MANOR - UNIT ONE 5.6' -t O o PLAT BOOK 13, PAGE 93 M LOT 10 r j� S89°36'40"W 150.00'(D&C) ®—------------------ Density: 9,300/26,753 = 34.7% x x x x x x x 6' C.L.F. 50'(D) 10' D.d.&U.E. x x_ x x 100'(P) 0,n° (NOT INCLUDED) x = FENCE I X��P 1.8'W— 0.9's x I EAST 50' x — — — 10.0' OF LOT 10 EXISTING CONTOURS Proposed Land Use: Light Manufacturing x 65.3' 1 ------ = PROPOSED CONTOURS Parking Required: Q1 0 = DRAINAGE BOUNDARY I I LOT 11 � --- = DRAINAGE FLOW 00 0. Parking Provided: 13 Spaces w/ 1 Handicapped Spaces _ X—X—X-- = DEMO All9 REMOVE CHAIN LINK x = FENCE x I USE 6" 3)00# CONCRETE 100 Year Flood Plain Not Applicable To Project UFH -p Existing vegetation – Landscaped _U - ----_ FENCING AND GATE. 0 x I O u CA ®P1 RO are shown on plans. Ivx o 0 ONE-STORY om ' Site has no known archaeoligical or historic resources. o ALUMINUM BLDG �o .. = WATER LINE WITH SIZE x #124 N N retention areas, and other onsite facilities. REMAINDER OF RV = 100.00 AASUMED v' �9 zo SANITARY SEWER LOT 10 10.0' 15.0'I (NOT INCLUDED) x I C/)24.9' –j'---20.0- --1.1'W FENCE o I I /� x x 6' C.L.F. x I TRACT "A" 1.8'W N DRAINAGE CONC. o I RETENTION I nAnimn•' o I AREA L1 N89°36'40"E 71.34' (D&C) N89'36'40"E COMMERCE WAY 50' R/W PER PLAT PRIVATE ROADWAY & U.E. FND NAIL NO I.D. EXISITNG SITE & DEMO PLAN L1 N89°36'40"E 71.34' (D&C) FND NAIL NO I.D. PROJECT ®A TA: Project Area 26,753 Sq.Ft. 0.614 Acres EXISTING: FENCE 1.8'W C7 I I ELEV = 96.0 10.01 15.0' CONC. c? LOADING" RAMP5.0, 140.1' 29.7' o CONC. ' oo 10' D.E.&U.E. L1 DRIVE WPP N ' U1 O N89'36'40"E — 430.51'(M) COMMERCE WAY 50' R/W PER PLAT PRIVATE ROADWAY & U.E. ACADEMY MANOR - UNIT ONE 5.6' -t O o PLAT BOOK 13, PAGE 93 M Building W/Addition 9,300 Sq.Ft. 13.5% r j� S89°36'40"W 150.00'(D&C) ®—------------------ Density: 9,300/26,753 = 34.7% x x x x x x x 6' C.L.F. 50'(D) 10' D.d.&U.E. x x_ x x 100'(P) 0,n° 'x L.F. x x 6 C. = FENCE I X��P 1.8'W— 0.9's x I EAST 50' `-20.0' — — — 10.0' OF LOT 10 EXISTING CONTOURS Proposed Land Use: Light Manufacturing x 65.3' 1 ------ = PROPOSED CONTOURS Parking Required: Q1 Office Area: 400/200 = 2 Spaces = DRAINAGE BOUNDARY x I LOT 11 � --- = DRAINAGE FLOW Total Parking Required = 13 Spaces Parking Provided: 13 Spaces w/ 1 Handicapped Spaces _ X—X—X-- = 5' WIDE PC JR BACK STRIP. x = FENCE x 4— = USE 6" 3)00# CONCRETE 100 Year Flood Plain Not Applicable To Project UFH O Existing vegetation – Landscaped _U - ----_ Contractor shall sod all areas in the Right–Of–Way 0 x I O u CA ®P1 Q are shown on plans. Ivx o 0 ONE-STORY om ' Site has no known archaeoligical or historic resources. o ALUMINUM BLDG �o .. = WATER LINE WITH SIZE x #124 N N retention areas, and other onsite facilities. REMAINDER OF RV = 100.00 AASUMED v' �9 zo SANITARY SEWER LOT 10 (NOT INCLUDED) x I C/)24.9' –j'---20.0- o L1 N89°36'40"E 71.34' (D&C) FND NAIL NO I.D. PROJECT ®A TA: Project Area 26,753 Sq.Ft. 0.614 Acres EXISTING: FENCE 1.8'W C7 I I ELEV = 96.0 10.01 15.0' CONC. c? LOADING" RAMP5.0, 140.1' 29.7' o CONC. ' oo 10' D.E.&U.E. L1 DRIVE WPP N ' U1 O N89'36'40"E — 430.51'(M) COMMERCE WAY 50' R/W PER PLAT PRIVATE ROADWAY & U.E. CONCRETE. �- -.DRIVEWAY I' D� CD FND NAIL NO I.D. h� ti \ PROPOSED SITE PLA Building Coverage 7,500 Sq.Ft. 6.8% 0.4 Other Impervious 12,360 Sq.Ft. 16.7% 5.6' -t O o M Building W/Addition 9,300 Sq.Ft. 13.5% r Other Impervious 10,560 Sq. Ft. 23.5% Green Areas 6,893 Sq.Ft. 63.0% CONCRETE. �- -.DRIVEWAY I' D� CD FND NAIL NO I.D. h� ti \ PROPOSED SITE PLA Building Coverage 7,500 Sq.Ft. 6.8% Other Impervious 12,360 Sq.Ft. 16.7% Green Areas 6,893 Sq.Ft. 76.5% PROPOSED: Building W/Addition 9,300 Sq.Ft. 13.5% Other Impervious 10,560 Sq. Ft. 23.5% Green Areas 6,893 Sq.Ft. 63.0% Density: 9,300/26,753 = 34.7% = EXISTING ELEVATIONS Project Zoning: City of Sanford: C X��P PROPOSED ELEVATIONS Project Tax Parcel #: 35-19-30-524-0000-0100 EXISTING CONTOURS Proposed Land Use: Light Manufacturing ------ = PROPOSED CONTOURS Parking Required: ,34 Office Area: 400/200 = 2 Spaces = DRAINAGE BOUNDARY Warehouse Area: (2) + 8,900/1000 = 11 Spaces Employees (2): 2 Spaces --- = DRAINAGE FLOW Total Parking Required = 13 Spaces Parking Provided: 13 Spaces w/ 1 Handicapped Spaces _ X—X—X-- = SILT FENCE Water Provider: City of Sanford (existing service) x = FENCE Sewer Provider: City of Sanford (existing) 4— = TRAFFIC FLOW 100 Year Flood Plain Not Applicable To Project UFH = EXISTING FIRE HYDRANT Existing vegetation – Landscaped 14'oak = EXISTING TREE TO REMAIN Contractor shall sod all areas in the Right–Of–Way 30'cheny = EXISTING TREE TO BE REMOVE disturbed by construction. All known easements, covenants, and Rights—of—way ®P1 = SOIL BORING are shown on plans. C2 = ZONING CLASSIFICATION Site has no known archaeoligical or historic resources. Hutchings Automotive, Inc. will be responsible for the = WATER LINE WITH SIZE maintenance of all open space, landscaping, drainage retention areas, and other onsite facilities. SANITARY SEWER FENCE 0.4'W K 0.9'S z 0 O CNsI 0 0 J rn 00 01 1-21 RO 1.1'W TRACT "A" DRAINAGE RETENTION AREA I