Loading...
3609 S Orlando Dr - BC01-002293 (ROSS) (WALL SIGN) (A) DOCUMENTSCITY OF SANFORD PERM-T APPLICATION ' Permit No. f ' Date: 5 y.3/ --621p© Job Address: 3CA ct /Jo CO D (Z c,? 7C - - - Permit Type: Building Electrical Mechanical Plumbing Fire AlaradSprinickr Description of Work: I t-6 L& 1 t L -i„l — -` l Cp-, 6 IP-6 Additional Information for Electrical & Plumbing Permits Electrical: —Addition/Alteration _Change of Service Temporary Pole _New AMP Service (0 of AMPS ) Plumbing/Residential: Addition/Alteration New Construction (One Closet Plus Additional) Plumbing/Commercial: Number of Fixtures Number of Water & Sewer Drainage Lines Number of Gas Lines Occupancy Type: Residential _Commercial _ Industrial Total SriFtg: Value of Work: S a Type of Construction: Flood Zone: Number of Stories: Number of Dwellingt Units: Parcel No.: (Attach Proof of Ownership & Legal Description) Owner/Address/Phone: \2-0 S S b P. ez, S r6 S S, o i*-Lis, 0 nu::q -it, R-L U -E: t-cP t2D ` 7 3 a Contractor/Address/Phone: leze>8 13 tc -J 5,LLICL CV R 1 Ale-, t= L , State L'nse Number: ammP Contact Person: F-©a 5- k b r Phone & Fax Number: 7. 22 • G7 q q ~,14 Title Holder (If other than Owner):` Address: Bonding Company:- Address: ` p Mortgage Lender: Jam' Address: . Architect/Engineer 1,,^- Address: /3 ZE v , [ nR-A z PL - 44 Phone No.: Mwlid= Application is hereby made to obtain a permit to do the work and installations as indicated I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING. SIGNS. WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, and AIR CONDITIONERS, etc. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is ve ' ati that I will notify the owner of the property of the uiremcnts of Flori i w, FS 713. n C Signature W4 //,,( o er/Agent Date Signature of ntractor/Agee Date 1 akw 1;> 11 S C t s C igpiatuare Owner/Agent's Name Print Contractor/Agent's Name Vv, //U` 0,14 of Notary- tatewof F lori da to ignature of Notary -Brat of Florida Date M. JOHNSON-- 20 :....' MY CCr.AMISSVON # CC 921808 2 zpR- 2004 JO ANNE}(plRES: March 23, M. JOHNSON sr ° bonded Thru Budget Notary services * * MY COMMISSION # CC 921808 re0F oP EXPIRES: March 23, 2004BondedThruBudget Owner/Agent is Personally Known to Me or Contractor/Agent is ---- 9 or, e o or Produced ID Produced ID Ft. t L Z 6© 3 2 APPLICATION APPROVED BY: Date: r 13-c rt Special Conditions: t t'rIJ INS i kUNYdtN 1 rkt#ARtI i ; r C-0 2Nor: ADDR. a4;®2: G ( 'ICE OtCOiwIlv)}_.NCEWNT Permit No. ax Folio No. i/ — 9,0 -30 40p• o- oocz) State of Florida j County of Seminole i The undersigned hereby gives notice that improvement will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement. L . Description of property: (legal description of the pr e r y ?nd street address if4v;ilable) Ste-, L 'C w Pac 1 R6.3a1". ti—ewr P_P 5u /_o'f' S '1.4,b.' .'>nf. ti`f a.oa'ef erIB& 76 2. General description of 3. Owner information a. Name and address S U D - : I" L. an-11 7 b. Interest in property A hl 5d t`-. '{`I UGC 9T W- c. Name and address of fee simple titleholder (if other than Owner) K( 4. Contractor i Name and address __J 06) t-'> TiF 01, 03 E R eTr C> IJ 5L— S 2--Lj c G b. Phone number 5. Surety a. Name and address O. J (:N b a. 5 0 Ce Fax number I IN III IN II all U UQIN11111Ill INIII III NIN111111011111111 b. Phone number Fax E MUHSL-, L'LEW U- UHL'U11-L'UURT c. Amount of bond BK 04137 PS 1196- 6, Lender CLERK'S # 2001728163 a, Name and address RECORDED n7i-3r 12001 03.47.11 GM RECORDING FEES 6.0 b. Phone number Fax nREUWD BY M Nolden 7. Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by Section 713.13(1)(a)7., Florida Statutes: a. Name and address > b Phone number _ Fax number 8. In addition to himself or herself, Owner designates of to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b), Florida Statutes. a. Phone number Fax number _ 9. Expiration date of notice of commencement (the expiration date is 1 year from the atTo dg unless a different s date is specified) f Si atu of Owner AJ 6- wo affirmed) subscribed before me this-34 dayof , 20 D / b-, Personally Known OR Produced Identification CERTIFIED COPY Type of Identification Produced MARYANNE MORSE CLERK OF CIRCUIT f? ITT PHYLLIS CARIELA SEMiNULE COUNTY. FLORIDA Commission rt 1169093 Signatu e f Notary Public, State of e,14UFvl vfi Z r 'j Notary ' ....® Note Public -California Commission Expires:—/1 o0a— ? 'i- . ` Alomeda CountyCLM My Comm. Expires Jan 11, 20021 A 31nn 20n1 E I i We cover k Boone Sign Erection and S ervice, Inc, s,•ro y 28 WEST MICMGAN STREET ORLANDO, FLORMA 32806 • (407) 422-6749 July 27, 2001 City of Sanford, Florida Building Department Permit Division Sanford, Florida 32771 - Re: Ross Dress For Less 3609 South OLLlanda Drive Sanford,, Florida 32771 Sign Permit Ra To Whom It May Concern: I hereby authorize Phillip E. Siekiera to obtain permits for BOONE SIGN ERECTION AND SERVICE, INC, effective from this date. I agree to notify you in writing if this authorization is revoked. IN TESTIMONY HEREOF, witness the..uridersigned's signature on this ,e 71 day of 20,o / i Signature: I.D. form,r, obert D. Boone, president' State of Florida Electrical Sign Contractor ER0011 167 E T 0 0 0 0 7 2 4. Subscribed and sworn, before me this day of 200/ Notary Public: Commission No. CC 7f 7 2&C . My commission expires:--/3 20 UL ShOa R Kirkland My Commission CC717936 Expires March 13, 2002 o _> July 23, 2001 City of Sanford Building Department Re: Ross Dress For Less 3609 South Orlando Drive Sanford, FL 32773 To Whom It May Concern: This letter shall serve as authorization by Bill Moore Associates, authorized sign consultants and licensed sign contractors for Ross Stores, Inc., for Boone Sign Erection & Service, a licensed contractor, to act as agent for Bill Moore & Associates i n the securing of permits and the installation of signage on behalf of Ross Dress For Less at the aforementioned property in accordance with the approved plans and specifications and subject to City of Sanford regulations and guidelines Sincerely, V Alastair F. Cun Vice President BILL MOORE & ASSOCIATES STATE OF CALIFORNIA COU +1TY OF ALAMEDA ON July 23, 2001, before me Phyllis Cariela, a Notary Public, personally appeared Alastair F. Cumming, who proved to me that he is the same and ,.,7ho signed the herein in my presence. IN TITNESS 'HEREOF, I have set my hand and affixed my official seal. FHYU_IS CAR!ELA a Commission 1169093 Zzc Notary Fub!ic, - Cal;iar is Alameda County MY Comm. Expires Jcn 11, 2002 IS 1057 solano avenue, albany, ca 94706 510.526.0296 Y Parcel Information 1wll Parcel: 11-20-30-300-0350-0000 Property:3605 ORLANDO DR SANFORD, FL 32771 Owner:KIMCO OF MERRITT ISLAND INC Mailing:C/O KIMCO REALTY CORP 3333 NEW PO BOX 5020 NEW HYDE PARK, NY 11042 0020 Legal: SEC 11 TWP 20S RGE 30E N 200 FT OF SW 1/4 OF SE 1/4 E OF ST RD & N 1/2 OF SE 1/4 OF SE 1/4 & BEG SEC COR OF NE 1/4 OF SE 1/4 RUN N 604.99 FT N 71 DEG 27 MIN 34 SEC W 1077.22 FT S 25 DEG 47 MIN W TO 26 .duly 2b61 TRY: 2001 TD: S4 DOR: 16 Page 1 of 5 SANFORD 17-92 REDVDS RETAIL CENTER -ANCHOR Exemption Homestead Year Granted: Amendment-10 Amendment-10 e Appraised % Addtion TotalPdbr_'Vfe r Total R % Land Value-- $3,639,872 $3,6 Extra Features 223,657 45,239 39,87 45,239 i- 0 56i 0,1016,581 BuildingValue4,656,520 3,106,681 Income Value 10,865,530 6, 791,692 37.4 91 7400 6, 791,692 37.4 TotalJustValue10,728,421 Correct Assd/Admin Value Classified Value E Amend 10 Adjustment, 0 00 total - Assessed -Value 10,865530 10,865,530 7,105,400 34.6 7,105,400 34.6 ale FDWDWARRANTY SU SQ Deed D WD - WARRANTY WD Description DEED TRUSTEE DEED ARRANTY DEED DEED DDEEDI VARRANTYDEEDSALES Sale Date _ORB 08/ 01/1989 04/ 01/1985 01/ 01/1985 01/ 01/1985 04/ 01/119-84 Book 02095 01609 016 , 69 01535 ORB Page 16i9 1096 1091 0642 Sale Amt -- - ----- _V/11 17 000,000 1, 500,000 100 1, 100,000 694, 82 1 QC r _ 00- V V 1 V 00 00 00 00 LAND CODE Land Rate Ag Rate Land Area Frontage D/T Depth Class Value 0%16Ajdj FOvA Reason Just Value AS 4.00 00 N_9,968.00. 909, 0.6b 0 3,639,87 GC-2 3,639,872 otal: TTota'. 3,639,872 3,639,M Brenda L. Samartino Assistant Property Manager Central Florida Regional office OVERNIGHT MAIL VIA FEDERAL EXPRESS July 17, 2001 Alastair F. Cumming Bill Moore & Associates 1057 Solano Avenue Albany, CA 947o6 Re: Ross Dress for Less 36o9 S. Orlando Drive Sanford, FL 32773 Telephone: 407-302-4400 Fax: 407-302-4440 Dear Mr. Cumming: This letter serves as written authorization for the installation of the approved fagade sign and pylon sign for the above Tenant per the attached specifications. The sign must be installed in accordance to exaA all city and local codes. In addition, you must obtain all necessary permits from the City of Sanford prior to the installation of the sign. If you have any questions or need additional information, please do not hesitate to contact me. Thank you. incere Brenda L Sam rtino Proper ager STATE OF FLORIDA COUNTY OF SEMINOLE The foregoing instrument was acknowledged before me this 17tn day of July 2001, by Brenda L. Samartino, who is personally known to me. t4 "i —!Z `ilavTOS iD1 73D507 i' .xiiKr^ f1owt.r3. N ary Pub 'c, . C'Docwnents And Settings\Bsamanino\My Documents\LL Approvals\SIGN.APP-BS.Doc 3705 S. Orlando Drive, Sanford, FI, 32773 OCT-29-2001 14:17 QORE, Inc. P.02/02 POST TENSIONINGISTEEL REPORT 0 E'. PRO P E R T Y S C I E NCES V 59B S. North take Blvd., Suite 1024 / Altamonte Springs, Florida 32701 1407-645-3400 407-645-3731 PROJECT: Wal-Mart Store #857 CMT Services Americana JOB NO: 9097 Blvd. & Us 17192 Sanford FL CLIENT: Wal-Mart Store, Inc. REPORT NO: 111078 TECHNICIAN: Ronald Kersey DATE OF EVALUATION: October 25, 2001 SECTION: 1458-3.6 WEATHER CONDITIONS: Partly Cloudy SUMMARY OF WORK PERFORMED: As requested, a QORE Property Sciences representative arrived on site and observed reinforcing steel at the north Loading Dock, west retaining wall footing. The reinforced steel observed appears to be in general accordance with the projects drawings and specifications with regards to bar size, length, spacing, quality and cleanliness. COPIES TO: Wal-Mart Store, Inc. I MS Laurie Demers (1) CPH Engineers, Inc / MS Diana Greene (1) Pinkerton & Laws / MR David Morton (3) r v Floridai3 gi E. 48574 TOTAL P.02 OCT-29-2001 14:17 QORE, Inc. A. P.01102 TM PRO P E RTY SC I E N C E S 1211 Tech Boulevard. Suite 200, Tampa, Florida 33619 813) 623-6646 phone (813) 623-3795 fax E-mail tampa@gore.net P401 To: Mr. ®avid Morton From: Mr. Oil Ramos Pas± 447-330-4741 Pages: 2 Phone. ®ate: I0aW01 Re: Foundation Inspection Report C: City of Samford$ QCRE Alta.. Pile X Urgent For Review For Coninient O P1ea3e Reply Plea3e Recycle Comments: City of Sanford 407-33O5677 OLD DIXIE HWY. U.S. HWY NO. 17 & 92 (S.R. 15 - 600) 4 17 Midway 92 GENEVA AVE. 46 Sanford Airport AIR PORT BLVD. SITE Hunt LAKE MARY BLVD. Cameron City Lake z Mary 0 a o 417 427 17 92 LAKE JESSUP 15 600 IN VICINITY MAP NOTES: SEE SHEET S1 FOR ROSS BUILDING SIGN LOCATIONS AND DETAILS SEE SHEET P FOR ROSS PYLON SIGN LOCATIONS AND DETAILS N.T.S. REVISED bill moore & associates 510) 526-0296 fax 526-6092 1057 solono ove. P.o. box 6153 albany, ca 94706 WENDY'S RETAIL PROPOSED RETENTION 1 BANK KFC S2 71 1 ROSS DRESS NW LESS m 0 z u PROPOSED RETENTION 1 1 , SITE PLAN N.T.S. SEMINOLE CENTER SHEET 3609 S. Orlando Drive, Suite #100 SANFORD, FL 119 DEC 00 72"H INDIVIDUAL ALUMINUM PAN -CHANNEL - - -- LETTER-LOK "ROSS" LOGO LETTERS. FACES: LEXAN 5G 308-22136 MATTE BLUE RETURNS: 81D ALUM. W/ BRITE DIP CHROME FINISH TRIM CAP: 2" SILVER JEWELITE TRIM NEON: FOUR -TUBE 15MM EGL E40 POWDER BLUE MOUNTING: 1/4"-20 GALV HANGEI Q_L_T,`j___-- PEG OFF: 1/2" SPACERS 42"H INDIVIDUAL ALUMINUM PAN -CHANNEL LETTER-LOK "DRESS FOR LESS" LOGO LETTERS. ALL CALLOUT5 SAME AS "ROSS" EXCEPT: RETURNS: 5"D ALUM. W/ BRITE DIP CHROME FINISH TRIM CAP: 1" SILVER JEWELITE TRIM NEON: THREE -TUBE 15MM EGL E40 POWDER BLUE EQUAL a Uj N n i BLUE TILE ACCENT 13AND5 BY LANDLORD NOTES: LANDLORD TO FURNISH ADEQUATE ACCE55 BEHIND LOGO LETTERS FOR INSTALLATION AND MAINTENANCE, PER ARTICLE 600 OF THE 1993 N.E.C. LANDLORD TO SUPPLY THREE (3) 20 AMP 120V DEDICATED SIGN CIRCUITS AND JUNCTION 13OXE5 TO AREA BEHIND SIGN LETTERS CONNECTED TO THE ENERGY MANAGEMENT 5Y5TEM (CIRCUITS MUST HAVE #10 WIRE MINIMUM rCONNECTED DIRECTLY TO PANEL WITH NO COMMON GROUNDS OR NEUTRAL5) IF SIGN BACKGROUND 15 E.I.F.5., LANDLORD TO PROVIDE PLYWOOD BACKING 1/2" THICK MINIMUM) EXTENDING A MINIMUM OF 12" BEYOND SIGN AREA. SIGN BACKGROUND FOR THE'RO55 DRE55 FOR LE55' SIGN(5) LETTERS TO BE OF A LIGHT COLOR (MINIMUM 75% L.R.V.) TO PROVIDE HIGH CONTRAST AND V15113ILITY FOR THE BLUE SIGN; SUCH AS SHERWIN WILLIAMS LIMOGE CREAM. THE 13A5E BUILDING COLOR TO HAVE A MINIMUM L.R.V. OF 55%. ALL COLORS ARE SUBJECT TO ROSS STORES, INC. REVIEW AND APPROVAL. CV to m 42'-0" 24'-0" 11 iZ'0551 DR-ESS FOR LESS O 4 23" X 46" X 10" DOUBLE -FACE --- INTERNALLY 1!.LUMINATED UNDER -CANOPY SIGN, MINIMUM 8'-0" ABOVE FINISH FL. CENTER OVER ENTRANCE DOORS SEE SHEET UC FOR DETAILS) REVI5ED 09 JAN 01 1 t4y A bill moore & associates 510)526-0296 fax 526-6092 1067 solano avep.o. box 6153 olbony, cc 94706 EQUAL 0 ARCHITECTURAL LIGHTING BY LANDLORD 24" H X 48"W X 1" DEEP STEEL PAN OVAL ' RO55' LOGO WALL PLAQUE 40'- O" WITH PORCELAIN ENAMEL FINISH TWO ( 2) REQ'D AS SHOWN SEE SHEET EL FOR DETAILS) LANDLORD TO CREATE FLAT EVEN SURFACE 12" MIN. AROUND PLAQUES. EQ 48f', EQ 2411 72" STOREFRONT • SOUTH • ELEVATION SCALE: 3/32" = 1'- 0" SEMINOLE CENTER 3609 S. Orlando Drive, Suite #100 SANFORD, FL. SHEET S1 04 DEC 00 i i i 7211 TYP. WHITE ELECTROBIT ELECTODE CAP 4 i NEON : 15MM 4/T EGL'S E40 BLUE NEON CONNECTORS : ELECTROBIT EC5: ELECTRO CAPS 4211 DR E5 151,30 - r [12/30] -- 60.2' i 57.2' 29.2' 31' 28.7 28.5' NEON : 15MM 3/T EGL'S E40 BLUE NEON CONNECTORS : ELECTROBIT EC5: ELECTRO CAPS 62.6' cl, TYP. FEED HOLE W/ SPACER BEHINE TYP. 15MM EGL E-40 \ POWDER BLUE NEON UNITS, 51ZES A5 NOTED 241_0_ OR 59.1' ' 28.5' 23.2' 28.1' NOTES: NEON & WIRING LAYSEESHEET51FORSIGNLOCATION SIGN MUST MEET U.L. 2161 AND 1999 NEC SPECIFICATIONS ELECTRICAL CONTRACTOR TO SUPPLY THREE (3) 20 AMP 120 VOLT DEDICATED SIGN CIRCUITS. IN ORDER FOR THE UL 2161 GFI SIGN TRANSFORMERS TO OPERATE PROPERLY EACH SIGN CIRCUIT MUST BE AN ISOLATED (DEDICATED) 20AMP 120VOLT SINGLE PHASE CIRCUIT WITH EQUIPMENT GROUND AND NO COMMON NEUTRAL OR GROUND WIRES. WIRE GAUGE FOR EACH 2OAMP CIRCUIT MUST BE SIZED FOR A 16AMP LOAD IN ACCORDANCE WITH THE NATIONAL ELECTRIC CODE FOR NO MORE THAN 2% VOLT DROP OVER THE LENGTH OF THE RUN. CIRCUITS MUST BE TERMINATED IN JUNCTION BOXES WITHIN FIVE FEET OF THE SIGN AND CONNECTED TO THE ENERGY MANAGEMENT SYSTEM. 31' TYP. MOUNTING W/ 5PACER BEH LE 9/301 45.0' 16.3' 28.7 OUT L ISTDED72"/42"( N.T.S. REVI5ED I 17;7M bill moore & associates 510) 526-0296 fax 526-6092 1057 soiano ove- p.o. box 6153 albany, co 94706 115/30 - DUPLICATE i i I i 55 112/30 57 28.5' BLUE 28.5' ROBS: 15.00 AMPS DFI: 18.75 AMPS TOTAL: 33.75 AMPS SEMINOLE CENTER 3609 S. Orlando Drive, Suite #100 SANFORD, FL. SHEET w 1 17 JUL 01 5" 1 /2" 8" 1/2" 063 BRIGHT -DIP CHROME FINISH ALUMINUM LETTER RETURN 1" SILVER JEWELITE TRIM CAP - 177 LEXAN 56308-22136 MATTE BLUE LETTER -FACE 15MM EGL E-40 BLUE NEON TUBING FOUR -TUBE) WALL SYSTEM ACTOWN 120V 30MA REMOTE VERSAMOUNT FULLY ENCLOSED TRANSFORMER INSIDE CANOPY ELECTROBIT END CAP (EC) OR SHORT STOP (55) UL #E85773 GTO CABLE WITH SLEEVE - 1/2" WATERPROOF FLEXIBLE CONDUIT TO REMOTE TRANSFORMER 120V ISOLATED ELECTRICAL PRIMARY 080 ALUMINUM LETTER -BACK PRIME AND FOG INTERIOR WHITE 511 ANDARD GLASS TUBE -SUPPORT 1/4" 5TNL5. 5TL. HANGER -BOLT WITH 1/2" NON -CORROSIVE SPACER S LISTED TYPICAL SECTION AT "DRESS FOR LESS" LETTER MOUNT REMOTE BALLAST LETTERS NOTES: THIS DRAWING FOR SIGN REFERENCE ONLY ... NOT FOR CONSTRUCTION CONTRACTOR TO PROVIDE FOR: REVISE P 1. PLYWOOD OR BLOCKING AT SIGN LOCATION (IF FASCIA IS E.I.F.S.) 2. ACCESS BEHIND FASCIA AT SIGN LOCATIONS FOR INSTALLATION WIRING AND MAINTENANCE PER ARTICLE 600 OF THE N.E.C. ELECTRICAL CONTRACTOR TO SUPPLY TWO 20AMP 120V SINGLE- PHASE ISOLATED SIGN CIRCUITS (NO COMMON NEUTRAL OR GROUND) AND J-BOXES BEHIND SIGN FASCIA CONNECTED TO E.M.S. 063 BRIGHT -DIP CHROME FINISH ALUMINUM LETTER RETURN 2" SILVER JEWELITE TRIM CAP 177 LEXAN SG308-22136 - MATTE BLUE LETTER -FACE STANDARD GLASS TUBE -SUPPORT 15MM EGL E-40 BLUE NEON TUBING FOUR -TUBE) WALL SYSTEM - - ACTOWN 120V 30MA REMOTE VER5AMOUNT FULLY ENCLOSED TRANSFORMER INSIDE CANOPY ELECTROBIT END CAP (EC) OR SHORT STOP (55) UL #E85773 GTO CABLE WITH SLEEVE 1/2" WATERPROOF FLEXIBLE CONDUIT TO REMOTE TRANSFORMER 120V ISOLATED ELECTRICAL PRIMARY 080 ALUMINUM LETTER -BACK PRIME & FOG INTERIOR WHITE 1/4" 5TNL5. 5TL. HANGER -BOLT WITH 1/2" NON -CORROSIVE SPACER NOTE: FOR ROSS LETER5 WE RECOMN ONE 1/4" ALL -THREAD THRU-BOLT WITI NUT AT THE TOP OF EACH LETTER N.T.S. bill moore & associates 510)526-0296 fax 526-6092 1057 sodono ove p.o. box 6153 otpony, ca 94706 S LISTED TYPICAL SECTION AT "ROSS" LETTER MOUNT REMOTE BALLAST LETTERS SEMINOLE CENTER 3609 S. Orlando Drive, Suite #100 SANFORD, FL. N.T.S. SHEET SD 17 JUL 01 w z w z Q O H— w m CO ZZ w flc z_ ZJ Q DO w It = K 1" RIGID; PRIME & PAINT TO MATCH CEILING 1" X 1" METAL RETAINER PAINTED TO MATCH SULTAN BLUE TWO -LAMP 13ALLA5T 1" PIPE FLANGE 1" X 4" 'C' CHANNEL WELDED TO CABINET EDGE 0.177 (3/16") WHITE LEXAN FACES WITH 9-1/4" HIGH WHITE 'RO55' COPY AND 3/4" WIDE WHITE OUTLINE REVERSED OUT OF 3M 3630-157 5ULTAN BLUE VINYL OVERLAY 2" X 2" 'C' CHANNEL LAMP 5UPPORT WELDED TO CABINET EDGE F36-T12-DHO FLUORESCENT LAMP TYPICAL OF TWO (2) AT 9" O.C. FOG IN51DE OF CABINET WHITE CABINET EGDE PAINTED TO 1011MATCH 5ULTAN BLUE 01 SECTION A -A SCALE : 3" = V-0" NOTES: 5EE SHEET 51 FOR UNDER -CANOPY 51GN LOCATION. LANDLORD TO PROVIDE ACCESS ABOVE CEILING FOR 516N IN5TALLATION, AND 120V ELECTRICAL SERVICE AND J-BOX WITHIN FIVE (5) FEET OF SIGN LOCATION CONNECTED TO ENERGY MANAGEMENT SYSTEM. Z 3/4" --- 3/4" o w 1 4-3/4" 4-1/4" G- 1" F- 33-1/2" LOO to 46" UNDER -CANOPY SIGN ELEVATION SCALE: 1" = V-0" 21MARY X ABOVE F SIGN. 3 MEMBER 55ARY) i. ORT5 SHERS TWO) CUT TO HEIGHT AND IDE CABINET EILING. 1UM. CABINET: VT CABINET EDGE SULTAN BLUE. AN FACE WITH 5/4" WIDE WHITE 1 3630-157 INYL OVERLAY CONNECT N END CABINET INSTALLATION INSTRUCTIONS: DRILL SIX (6) 5/16" DIA. X 3 1/2" DEEP HOLES INTO WALL A5 PER PATTERN. SCREW 114-20 GALV. STUDS INTO EMPTY T-NUT5 IN BACK OF PLAQUE UNTIL THEY CONTACT CUP POINT SCREW DO NOT OVER TIGHTEN). FILL HOLES IN WALL AND COAT ALL -THREAD WITH RTV-6708 51LICONE ADHESIVE. MOUNT PLAQUE ONTO WALL PUSHING STUDS INTO HOLES UNTIL PLAQUE 15 FLUSH AGAINST WALL SURFACE. 3 1/2" HOLE Y' PLAQUE, 3 1/2" X 1/4-20 GALV. STUD. 1/2" MAX. SECTION AT MOUNT SCALE: 3/4" = 1 " NOTES: SEE SHEET 51 FOR PLAQUE LOCATIONS BILL MOORE & ASSOCIATES TO SUPPLY PLAQUES, HARDWARE AND INSTALLATION PATTERNS. MOUNTING DETAIL MAY VARY ACCORDING TO TYPE OF WALL CONSTRUCTION: LANDLORD TO VERIFY CONDITIONS AND PROVIDE FLAT EVEN SURFACE 12" MINIMUM AROUND WALL PLAQUE LOCATION(5). 24" X 48" X 1" STEEL PAN WITH BAKED PORCELAIN ENAMEL FIN15H 3/4" EXTERIOR GRADE MDO PLYWOOD ALL SURFACES PRIMED AND SEALED EPDXY GLUE BOND BETWEEN PLYWOOD AND STEEL PAN. FIN15H WALL MATERIAL 1/4-20 X 3.5 GALV. STUD TYPICAL OF SIX (6) THREADED 1/4-20 T-NUT WITH 1/4-20 X 0.125 CUP POINT SCREW N PRE-5ET INTO PLYWOOD BACKING. TYPICAL OF 51X (6) RTV-6708 51LICONE ADHESIVE 5/16" DIA. X 3" DEEP HOLE IN WALL TYPICAL OF 51X (6) a 44 0.25" CL FOR T-NUT5 Em 35" ROSS 16" 1 8" CL FOR T-NUT5 0.25" a N O OF,) Oo zz Z m c N - O a Q I '--- WHITE COPY j 3 PMS #296C DARK BLUE COPY OUTLINE Q PM5 #294C BLUE BACKGROUND 3 PM5 #296C DARK BLUE 15T OUTLINE j WHITE 2ND OUTLINE m PM5 #294C BLUE 3RD OUTLINE Q 1 OVAL ENTRANCE LOGO PLAQUE ELEVATION SCALE: 1-1/2"=1'-0" REV15ED - SEMINOLE CENTER SHEET 3609 S. Orlando Drive, Suite #100 bill moore & associates SANFORD FL. 510) 526-0296 fax 526-6092 1057 solano ave. p.o. box 6153 albany, ca 94706 EL 12 JAN 01 10 111 21'-0" 14'-0" CABINET D C OM 14 P0 - 0 ULO)- EXISTING 36'-O" HIGH X 21'-0" WIDE DOUBLE -FACE PYLON SIGN: STRUCTURE, LIGHTING, ELECTRICAL SERVICE AND FINISHES PROVIDED AND MAINTAINED BY LANDLORD. EXISTING "ROSS" TENANT FACES TO BE REPLACED WITH NEW AS SHOWN: 5'-0"± HIGH X 14'-O"± WIDE PAN -FORMED CLEAR ACRYLIC DECORATED SECOND -SURFACE WITH 38" HIGH WHITE "RO55" ON DARK BLUE BACKGROUND (TO MATCH PANTONE 286C) SIGN CONTRACTOR TO CHECK RETAINERS FOR DAMAGE, FADING OR PEELING ETC.: REPAIR, REPAINT OR REPLACE AS NECESSARY. RELAMP ROSS PORTION OF CABINET. CHECK BALLASTS: REPLACE AS NECESSARY. EXISTING DOUBLE -FACE PYLON SIGN ELEVATION REV(5ED I t; 7 A I bill moore & associates 510)526-0296 fax 526-6092 1057 solono ove p.o. box 6153 albony, co 94706 SCALE: 1/4" = 1'- 0" SEMINOLE CENTER CEO 3609 S. Orlando Dr. #100 SANFORD,FL OEM - SHEET p 19 DEC 00 i . S fie LI`iT' gAcie orov* Y U W U Lu U. uSTa PIPE 24n, O.C. W u. W I..-Z W — a oLu PRE ''go c' It De -A sic rA F A to J` N.' x t 0" MIN. A.F.F. 3/4"— Z 3/4" 1" 4-3/*' 33-1/2" LOGO 4-1/4 " 1" Ow OL to UNDER -CANOPY SIGN ELEVATION SCALE: 1" = 1'-o" NOTE; 1. DESIGN WIND PRESSURE IN CONFORMANCE W/ ASCE 7-95 vW MPH REGION. 2. PRE-ENG'RED SIGN FACE BY OTHERS. DELEGATE ENGINEER SHALL PROVIDE DESIGN DRAWINGS TO RICHARDSON ENGINEERING FOR APPROVAL PRIOR Tp FABRICATION OR ERECTION. 3. BOLTS: ASTM A307 4. CONTRAs;TOR SHALL 13E RESPONSIBLE FOR WATERPROOFING. RICH'ARDSON ENGINF CONSULTING ENGINEERS, O rR0„CGT. cum+r x!pptAm 1y! FW G8 RSs 1^1'7-01 0I00 /,.;', I ' I - mmm l' is. err ti i s r_ 0 0N N cn f*7 LO C ccj cu a 0 NOTE: - 1. DESIGN FIND PRESSURE IN CONFOkMANCE W/ ASCE 7-95 MPH EGION. 2. PRE-ENG-RED SIGN FACE BY OTHERS. DELEGATE ENGINEER SHALL PROVIDE DESIGN DRAWINGS TO RICHARDSON ENGINEERING FOR APPROVAL PRIOR TP FABRICATION OR ERECTION. 3. 60LTS: ASTM A307 4. CONTRACTOR SHALL BE RESPONSIRLE•FOR WATERPROOFING. RICEARDSON ENGINEERD4G,, CONSULTING ENGINEERS, OKLAiwI C Irp ar, GB RHt•? SANFORD BUILDING DEPT. THESE PLANS ARE REVIEWED AND CONOMONALLVACCEPTEDFORPERMIT. A PERMIT%SUED SHALL BeCONSTRUEDTOBEALICENSETOPROCEEDWITHITHEWORKANDNOTASAUTHORITYTOVIOLATE, CANCEL, ALTER, OR SET ASIDE ANY OF THIkPROVISIONSOFTHETECHNICALCODES, NOR SHALL, ISSUANCE OF A PERMIT PREVENT THE BUILDINGDEPTFROMTHEREAFTERREQUIRINGACORREQ, TION OF ERRORS ON THE PLANS, CONSTRUCTIONOROTHERVIOLATIONSOFTHECODES. City of Sanford Model Codes in effect: Standard Building Code 1997 ed. Standard Plumbing Code 1997 ed.• Standard Mechanical Code 1997 ed. National Electrical Code 1996 ed. See City Code AMENDMENTS FL. Accessibility Codes 1997 FL. Energy Code 1997 PLANS REVIEWED CITY OF SANFORD FINAL INSPECTION REQUIRED PERMIT #0l.zz93 OFFICE COP Y