Loading...
1151 Rinehart Rd - BC05-001108 (FIRE SPRINKLER SYSTEM) DOCUMENTST CITY OF SANFORD PERMIT APPLICATION SI �� Permit # : � a Date: �'�� /'Os Job Address: N r V iy Description of Work: _[Jsr, i LL. Alew Fi rR S5*PJjteJ1LL6Z SyS3Lnn Historic District: Zoning: Value of Work: $ .35� Soo. 00 Permit Type: Building Electrical Electrical: New Service — # of AMPS Mechanical: Residential Non -Residential Plumbing/ New Commercial: # of Fixtures Plumbing/New Residential: # of Water Closets Occupancy Type: Residential Commercial Construction Type: # of Stories: Parcel #: '32 -19 - Owners Z'19 - Owners Name & Address: Mechanical Plumbing Fire Sprinkle Alarm V Pool _ Addition/Alteration Change of Service Temporary Pole Replacement New (Duct Layout & Energy Calc. Required) _ # of Water & Sewer Lines # of Gas Lines Plumbing Repair — Residential or Commercial Industrial Total Square Footage: _ # of Dwelling Units: Flood Zone: (FEMA form required for other than X) (Attach Proof of Ownership & Legal Description) Phone: Contractor Name & Address: CRA1a FI7-6 5_r*'R11JV_L946 : CaR P. � .SS%t�8 A"oaee Aoylz I e-ly 02L. P1.. .32.03; State License Number: Phone & Fax: 4ai 438 - ¢)!ei Contact Person: Phone: Bonding Company: Address: Mortgage Lender: w 1 I , mss' Address: Architect/Engineer: �n�� I. �l1lJ� . ".`— Phone: Address: " s Fax: Ao Application is hereby made to obtain a permit to dQi}ie wor a EE%rdsplka lA'n i ate certifj that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to stytOj ng constructlan in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL FORK, �?LUMB �E L FURNACES OILERS, HEATERS, TANKS, and AIR CONDITIONERS, etc. • L . ._1 OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements Florida Lien Law, FS 713. � l //-oS Signature of Owner/Agent Date Sign tore of Contractor/Agent Date Print Owner/Agent's Name Signature of Notary -State of Florida Date Owner/Agent is _ Personally Known to Me or Produced ID 1AtGHAtFL S - C2A1,J rn Contra /Agent's Name l� O S' re of Notary -State of Florida Date CRY P c FLORENCE A. DE GRAVE * MY COMMISSION Il DD 164280 C tract. EXPIR h p✓(�t'"�Me or > Procliiced, d9et Irn<l •� �d v �_ APPLICATION APPROVED BY: Bldg-12C� 2 6 Zoning: Utilities: FD I#::�-,L5- - "I (Initial & Date) (Initial & Date) (Initial & Date) (Iniiial Special Conditions: T _ _ _ Fire Protection by Computer Design CRAIN FIRE SPRINKLERS CORP. 5518 FORCE FOUR PKWY ORLANDO FL. 32839 407-438-4767 Job Name RINEHART RETAIL LOT #2 Building RETAIL LOT #2 Location UNITS # 101 AND 102 System I Contract Data File RINEH.WX1 .� JAN Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 CRAIN FIRE SPRINKLERS CORP. Page I 'RINEHART RETAIL LOT #2 Date 12-15-12 Hydraulic Design Information Sheet Name - RINEHART RETAIL LOT 42 Date - 12-15-04 Location - UNITS # 101 AND 102 Building - RETAIL LOT 42 System No. - 1 Contractor - CRAIN FIRE SPRINKLERS, INC Contract No. - Calculated By - PWR Drawing No. - FP -2 Construction: ( ) Combustible (X) Non -Combustible Ceiling Height - 11'-0" Occupancy - NFPA-13 1999 EDITION, ORDINARY GROUP II HAZARD RETAIL SPACE S (X) NFPA 13 ( ) Lt. Haz. Ord.Haz.Gp. ( ) 1 (X) 2 ( ) 3 ( ) Ex.Haz. Y ( ) NFPA 231 ( ) NFPA 231C ( ) Figure Curve S Other T Specific Ruling Made By Date E M Area of Sprinkler Operation - 900 System Type Sprinkler/Nozzle Density - 0.20 (X) Wet Make RELIABLE D Area Per Sprinkler - 130 MAX ( ) Dry Model F1FR (R3612) E Elevation at Highest Outlet - 11'-0" ( ) Deluge Size 17/32" WHITE S Hose Allowance - Inside - -0- ( ) Preaction K -Factor 8.OK I Rack Sprinkler Allowance - -0- ( ) Other Temp.Rat.155* G Hose Allowance - Outside - +250.0 R K Flue Spacing N CRAIN FIRE SPRINKLERS, INC. Y Note THE SYSTEM IS DESIGNED TO PROVIDE 14.304 PSI SAFETY MARGIN Calclation Flow Required - Summery C -Factor Used: 213.78 Press Required 120 Overhead - 26.721 AT BSR 150 Underground W Water Flow Test: Pump Data: Tank or Reservoir: A Date of Test - 12-6-04 Cap. - T Time of Test - Rated Cap.- Elev.- E Static Press - 48.0 Q Press - R Residual Press - 35.0 Elev. - Well Flow - 1890.0 ( ) Encap. Proof Flow S Elevation - +2'-6" ( ) Solid Shelf ( ) Non U ( ) Open Shelf P Location - TEST HYDRANT IS LOCATED ACROSS THE STREET AT TOWN CENTER PLAZA P R K Flue Spacing L Source of Information - CRAIN FIRE SPRINKLERS, INC. Y Transverse C Commodity Class Location O Storage Ht. Area Aisle W. M Storage Method: Solid Piled % Palletized % Rack M ( ) Single Row ( ) Conven. Pallet ( ) Auto. Storage ( ) Encap. S R ( ) Double Row ( ) Slave Pallet ( ) Solid Shelf ( ) Non T A ( ) Mult. Row ( ) Open Shelf 0 C R K Flue Spacing Clearance:Storage to Ceiling A Longitudinal Transverse G E Horizontal Barriers Provided: Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Water Supply Curve (C) CRAIN FIRE SPRINKLERS CORP. RINEHART RETAIL LOT #2 I IN Page 2. Date 12-15-12 City Water Supply: C1 - Static Pressure : 48 PSI C2 - Residual Pressure: 35 PSI C2 - Residual Flow 1890 GPM 150 D2 -System Flow 213.78 GPM D2 -System Pressure 33.466 PSI Hose (Adj City ) GPM Hose ( Demand ) GPM D3 -System Demand 213.78 GPM Safety Margin 14.304 PSI D I -Elevation 6.063 PSI 140 130 P 120 R 110 C1 E 100 i S 90 1 S 80 U 70 R 60 E 50 40 30 20 10 200 400 600 800 1000 1200 1400 1600 1800 FLOW (N ^ 1.85 ) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 D2 -System Flow 213.78 GPM D2 -System Pressure 33.466 PSI Hose (Adj City ) GPM Hose ( Demand ) GPM D3 -System Demand 213.78 GPM Safety Margin 14.304 PSI C1 i 1 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Fittings Summary CRAIN FIRE SPRINKLERS CORP. RINEHART RETAIL LOT 92 Fitting Legend Abbrev. Name A Generic Alarm Va B Generic Butterfly Valve C Roll Groove Coupling D Dry Pipe Valve E 90' Standard Elbow F 45' Elbow G Gate Valve H 45' Grvd-Vic Elbow I 90' Grvd-Vic Elbow J 90' Grvd-Vic Tee K Detector Check Valve L Longi Turn Elbow M Medium Turn Elbow N PVC Standard Elbow O PVC Tee Branch P PVC 45' Elbow Q Flow Control Valve R PVC Coupling/Run Tee S Swina Check Valve T 90' Flow thru Tee U 45' Firelock Elbow V� 90' Firelock Elbow W Wafer Check Valve X1 90' Firelock Tee Y Mechanical Tee Z Flow Switch Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Page 3 Date 12-15-12 Fittings Summary 17.0 27.0 29.0 GRAIN FIRE SPRINKLERS CORP. B 9.0 10.0 12.0 19.0 Page 4 RINEHART RETAIL LOT #2 C 1.0 1.0 Date 12-15-12 Unadjusted Fittings Table 1.0 1.0 1.0 1.0 1.0 D 47.0 1/2 3/4 1 1 1/4 .I 1/2 2 21/2 3 31/2 4 12.0 14.0 18.0 22.0 27.0 35.0 40.0 45.0 A 61.0 F 5.0 7.0 7.7 21.5 13.0 17.0 B 21.0 24.0 28.0 G 7.0 10.0 4.0 12.0 C 1.0 LO 1.0 1.0 LO LO LO 1.0 1.0 1.0 D 8.5 10.0 18.0 20.0 9.5 17.0 30.0 28.0 E 2.0 2.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 10.0 F 1.0 1.0 1.0 1.0 2.0 2.0 3.0 3.0 3.0 4.0 G 98.0 120.0 K LO 1.0 1.0 1.0 2.0 1-1 1.0 1.5 2.0 2.0 3.0 3.0 3.5 3.5 1 2.0 3.0 4.0 3.5 6.0 5.0 8.0 7.0 J 4.5 6.0 8.0 8.5 10.8 13.0 17.0 16.0 K 14.0 14.0 L 1.0 1.0 2.0 2.0( 2.0 3.0 4.0 5.0 5.0 6.0 M 2.0 2.0 3.0 3.0 4.0 5.0 6.0 6.0 8.0 N 7.0 7.0 7.0 8.0 9.0 11.0 12.0 13.0 33.0 O 3.0 3.0 5.0 6.0 8.0 10.0 12.0 15.0 R 1' 1.0 1.0 1.0 2.0 2.0 2.0 3.0 4.0 Q S 27.0 32.0 18.0 55.0 29.0 76.0 35.0 R 1.0 1.0 1.0 1.0 1.0 1.0 2.0 2.0 50.0 60.0 S 4.0 5.0 5.0 7.0 9.0 11.0 14.0 16.0 19.0 22.0 "r 3.0 4.0 5.0 6.0 8.0 10.0 12.0 15.0 17.0 20.0 U 13.0 1.8 2.2 2.6 3.4 V 13.1 31.8 3.5 4.3 5.0 6.8 W x 21.0 25.0 33.0 10.3 X 8.5 10.8 13.0 16.0 Y 2.0 4.0 5.0 6.0 8.0 10.5 12.5 15.5 12.0 22.0 "L 2.0 2.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 10.0 I Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 5 6 8 10 12 14 16 18 20 24 A 17.0 27.0 29.0 B 9.0 10.0 12.0 19.0 21.0 C 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 D 47.0 E 12.0 14.0 18.0 22.0 27.0 35.0 40.0 45.0 50.0 61.0 F 5.0 7.0 9.0 11.0 13.0 17.0 19.0 21.0 24.0 28.0 G 2.0 3.0 4.0 5.0 6.0 7.0 8.0 10.0 11.0 13.0 1-1 4.5 5.0 6.5 8.5 10.0 18.0 20.0 23.0 25.0 30.0 1 8.5 10.0 13.0 17.0 20.0 23.0 25.0 33.0 36.0 40.0 J 21.0 25.0 33.0 41.0 50.0 65.0 78.0 88.0 98.0 120.0 K 36.0 55.0 45.0 L 8.0 9.0 13.0 16.0 18.0 24.0 27.0 30.0 34.0 40.0 M 10.0 12.0 16.0 19.0 22.0 N O 1' Q 33.0 R S 27.0 32.0 45.0 55.0 65.0 76.0 87.0 98.0 109.0 130.0 T 25.0 30.0 35.0 50.0 60.0 71.0 81.0 91.0 101.0 121.0 U 4.2 5.0 5.0 V 8.5 10.0 13.0 W 13.1 31.8 35.8 27.4 x 21.0 25.0 33.0 Y L 12.0 14.0 18.0 22.0 27.0 35.0 40.0 45.0 50.0 61.0 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 E Pressure / Flow Summary - STANDARD CRAIN FIRE SPRINKLERS CORP. Page 5 RINEHART RETAIL LOT #2 Date 12-15-12 Node E--levation K -Fact Pt Pn Flow Density Area Press No. Actual Actual Rea. A 11.0 8 9.92 Ila 13 11.0 8 10.25 Ila C 11.0 8 11.46 Ila D 11.0 8 9.96 Ila E 11.0 8 10.29 Ila F 11.0 8 11.5 Ila G 11.0 8 12.86 Ila FI 11.0 8 13.29 Ila A 1 12.66 11.76 Ila 131 12.66 12.17 Ila Cl 12.66 13.67 Ila DI 12.66 11.81 Ila E1 12.66 12.22 Ila F1 12.66 13.72 Ila GI 12.66 15.4 Ila F1 12.66 15.92 Ila RN 1 11.96 18.07 Ila RN2 11.96 18.13 Ila RN3 11.96 18.59 Ila CN/II 11.96 18.61 Ila CM2 11.96 18.67 Ila CM3 11.96 18.9 Ila CM4 11.96 19.31 Ila TSR 3.0 26.72 Ila 13SR -3.0 30.18 Ila UGI -3.0 30.36 Ila UG2 3.0 28.69 Ila [3K I 3.0 28.75 Ila QK2 ' -3.0 33.4 na UG3 -3.0 33.46 Ila SRC -3.0 33.47 Ila The maximum velocity is 11.27 and it occurs in the pipe between nodes F1 and RN2 25.2 .2 126 7.0 25.62 .2 126 7.0 27.08 .2 126 7.0 25.24 .2 126 7.0 25.66 .2 126 7.0 27.13 .2 126 7.0 28.69 .2 126 7.0 29.16 .2 126 7.0 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 c � Find Calculations - Standard CRAIN FIRE SPRINKLERS CORP. Page 6 RINEHART RETAIL LOT #2 Date 12-15-12 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes ****** Point Qt Pt7UL Eqv. Ln. Total Pf Pn A 25.20 1.049 2E 2.000 3.830 9.922 K Factor = 8.00 to 120 1 T 5.000 9.000 -0.719 Al 25.2 0.1995 12.830 2.560 Vel = 9.355 0.0 25.20 11.763 K Factor= 7.35 B 25.62 1.049 2E 2.000 3.830 10.252 K Factor = 8.00 to 120 1 T 5.000 9.000 -0.719 B 1 25.62 0.2058 12.830 2.640 Vel = 9.511 0.0 25.62 12.173 K Factor= 7.34 C 27.08 1.049 2E 2.000 3.830 11.461 K Factor = 8.00 to 120 IT 5.000 9.000 -0.719 C 1 27.08 0.2280 12.830 2.925 Vel = 10.053 0.0 27.08 13.667 K Factor= 7.33 D 25.24 1.049 2E 2.000 3.830 9.957 K Factor = 8.00 to _ 120 1T 5.000 9.000 -0.719 Dl 25.24 0.2002 12.830 2.568 Vel = 9.370 0.0 J 25.24 11.806 K Factor= 7.35 E 25.66 1.049 2E 2.000 3.830 10.288 K Factor = 8.00 to 120 IT 5.000 9.000 -0.719 E 1 25.66 0.2063 12.830 2.647 Vel = 9.526 0.0 25.66 12.216 K Factor= 7.34 F 27.13 1.049 2E 2.000 3.830 11.500 K Factor = 8.00 to 120 IT 5.000 9.000 -0.719 Fl 27.13 0.2288 12.830 2.935 Vel = 10.071 0.0 27.13 13.716 K Factor= 7.33 G 28.69 1.049 2E 2.000 3.830 12.865 K Factor = 8.00 to 120 1 T 5.000 9.000 -0.719 G1 28.69 0.2537 12.830 3.255 Vel = 10.650 0.0 28.69 15.401 K Factor= 7.31 H 29.16 1.049 2E 2.000 3.830 13.285 K Factor = 8.00 to 120 1 T 5.000 9.000 -0.719 HI 29.16 0.2614 12.830 3.354 Vel = 10.825 0.0 29.16 15.920 K Factor= 7.31 A 1 25.20 1.682 1 T 9.900 10.500 11.764 to 120 9.900 0.0 B 1 25.2 0.0200 20.400 0.408 Vel = 3.639 B1 25.62 1.682 1T 9.900 10.500 12.172 to 120 9.900 0.0 Cl 50.82 0.0733 20.400 1.495 Vel = 7.338 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Standard CRAIN FIRE SPRINKLERS CORP. Page 7 RINEHART RETAIL LOT #2 Date 12-15-12 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes ****** Point Qt Pf/UL Eqv. Ln. Total Pf Pn CI 27.08 1.682 1T 9.900 15.500 13.667 to 120 9.900 0.303 RN 1 77.9 0.1615 25.400 4.103 Vel = 11.248 0.0 77.90 18.073 K Factor= 18.32 D l 25.24 1.682 1 T 9.900 10.500 11.806 to 120 9.900 0.0 E 1 25.24 0.0201 20.400 0.410 Vel = 3.644 El 25.66 1.682 1T 9.900 10.500 12.216 to 120 9.900 0.0 F1 50.9 0.0735 20.400 1.499 Vel = 7.349 FI 27.13 1.682 IT 9.900 15.500 13.716 to 120 9.900 0.303 RN2 78.03 0.1620 25.400 4.115 Vel = 11.267 0.0 78.03 18.134 K Factor= 18.32 G1 28.69 1.682 1T 9.900 10.500 15.401 " to 120 9.900 0.0 H1 28.69 0.0254 20.400 0.519 Vel = 4.143 H1 29.16 1.682 IT 9.900 15.500 15.920 to 120 9.900 0.303 RN3 57.85 0.0931 25.400 2.366 Vel = 8.353 0.0 57.85 18.589 K Factor= 13.42 RN 1 77.90 2.157 1 X 10.461 0.660 18.073 to 120 10.461 0.0 CM 1 77.9 0.0481 l l .121 0.535 Vel = 6.840 0.0 77.90 18.608 K Factor= 18.06 RN2 78.03 2.157 1X 10.461 0.660 18.135 to 120 10.461 0.0 CM2 78.03 0.0483 11.121 0.537 Vel = 6.851 0.0 78.03 18.672 K Factor = 18.06 RN3 57.85 2.157 1X 10.461 0.660 18.589 to 120 10.461 0.0 CM3 57.85 0.0277 11.121 0.308 Vel =. 5.079 0.0 57.85 18.897 K Factor= 13.31 CMI 77.90 4.26 1 T 26.334 10.000 18.608 to 120 26.334 0.0 CM2 77.9 0.0018 36.334 0.064 Vel = 1.754 CM2 78.03 4.26 IT 26.334 9.580 18.671 to 120 26.334 0.0 CM3 155.93 0.0063 35.914 0.227 Vel = 3.510 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Standard CRAIN FIRE SPRINKLERS CORP. Page 8 'RINEHART RETAIL LOT #2 Date 12-15-12 Hyo. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes ****** Point Qt Pf/UL Eqv. Ln. Total Pf Pn CM3 57.85 4.26 1T 26.334 10.000 18.898 to 120 26.334 0.0 CM4 213.78 0.0113 36.334 0.411 Vel = 4.812 CM4 0.0 4.26 IV 8.954 303.000 19.309 to 120 8.954 3.881 TSR 213.78 0.0113 311.954 3.531 Vel = 4.812 TSR 0.0 4.26 IV 8.954 8.960 26.721 to 120 IS 28.968 66.889 2.599 BSR 213.78 0.0113 IB 15.800 75.849 0.859 Vel = 4.812 1Z 13.167 BSR 0.0 4.26 IL 11.938 12.000 30.179 to 150 11.937 0.0 UGI 213.78 0.0075 23.937 0.179 Vel = 4.812 UGI 0.0 4.53 2L 16.103 135.000 30.358 to I50 32.204 -2.599 UG2 213.78 0.0056 167.204 0.929 Vel = 4.256 UG2 0.0 4.1 6.000 28.688 to 140 0.0 0.0 BK1j 213.78 0.0103 6.000 0.062 Vel= 5.195 BK1 , 0.0 4.26 6.000 28.750 to 140 0.0 4.599 Fixed loss = 2 BK2 213.78 0.0085 6.000 0.051 Vel = 4.812 BK2 0.0 4.1 6.000 33.399 to 140 0.0 0.0 UG3 213.78 0.0103 6.000 0.062 Vel = 5.195 UG3 0.0 8.547 l R 0.0 10.000 33.461 to 150 1G 7.990 8.438 0.0 SRC 213.78 0.0003 to 0.0 18.438 0.005 Vel = 1.195 .0 213.78 33.466 K Factor= 36.95 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 4 Model F1 FR Sprinkler Types Standard Upright Standard Pendent Conventional Vertical Sidewall Horizontal Sidewall - HSW 1 Deflector Model F1 FR Recessed Sprinkler Types Recessed Pendent Recessed Horizontal Sidewall — HSW 1 Deflector Listings & Approvals 1. Listed by Underwriters Laboratories, Inc. (UL) 2. Listed by Underwriters' Laboratories of Canada (ULC) 3.Certified by FM Approvals 4. Loss Prevention Council (LPC, UK) S. NYC BS&A No. 587 -75 -SA 6. Meets MIL -S -901C and MIL -STD 167-1 7. Verband der Schad enversicherer (VdS, Germany) 8. NYC MEA 258-93-E UL Listing Category Sprinklers, Automatic & Open ' Quick Response Sprinkler UL Guide Number VNIV Product Description Reliable Models F1 FR and F1 FR Recessed Sprinklers are quick response sprinklers which combine the durability of a standard sprinkler with the attractive low profile of a decorative sprinkler. The Models F1 FR and F1 FR Recessed automatic sprinklers utilize a 3.0 mm frangible glass bulb. These sprinklers have demonstrated response times in laboratory tests which are five to ten times faster than standard response sprinklers. This quick response enables the Model F1 FR and F1 FR Recessed sprinklers to apply water to a fire much faster than standard sprinklers of the same temperature rating. The glass bulb consists of an accurately controlled amount of special fluid hermetically sealed inside a precisely manufac- tured glass capsule. This glass bulb is specially constructed to provide fast thermal response. The balance of parts are made of brass, copper and beryllium nickel. At normal temperatures, the glass bulb contains the fluid in both the liquid and vapor phases. The vapor phase can be seen as a small bubble. As heat is applied, the liquid ex- pands, forcing the bubble smaller and smaller as the liquid pressure increases. Continued heating forces the liquid to push out against the bulb, causing the glass to shatter, opening the waterway and allowing the deflector to distrib- ute the discharging water. The temperature rating of the sprinkler is identified by the color of the glass bulb. Bulletin 136 Rev.L Model F1 FR Model F1 FR Recessed Quick Response Sprinklers t Upright Vertical Sidewall Horizontal Sidewall HSW 1 Deflector Pendent Conventional Recessed Pendent Application Quick response sprinklers are used in fixed fire protec- tion systems: Wet, Dry, Deluge or Preaction. Care must be exercised that the orifice size, temperature rating, deflector style and sprinkler type are in accordance with the latest published standards of the National Fire Protection Asso- ciation or the approving Authority Having Jurisdiction. Quick response sprinklers are intended for installation as specified in NFPA 13. Quick response sprinklers and stan- dard response sprinklers should not be intermixed. The Reliable Automatic Sprinkler Co., Inc. 525 North MacQuesten Parkway, Mount Vernon, New York 10552 Model F1 FR Quick Response Upright, Pendent & Conventional Sprinklers Installation Wrench: Model D Sprinkler Wrench Installation Data: Sprinkler Type Thread Size K Factor K Factor Sprinkler Height Sprinkler Identification Standard -Upright (SSU) and Pendent (SSP) US Metric Sprinkler Approval Number SIN Deflectors Marked to Indicate Position Us Metric Height Organization NPT R'/� ( ) 8.0 -- 115 2.3" (58mm) 1,2,3 R3612 SSU SSP (15mm) Standard Orifice with r" NPT (Ry) Thread 5.6 80 2.2" 56mm 1,2,3,4,5,6,7 R3625 R3615 "' " 20mm I Lar e Orifice with "NPT R3/e Thread 8.0 115 2.3" 58mm 1,2,3,4,7,8 R3622 R3612 " 17mm Small Orifice with " NPT Ry) Thread 4.2 1 60 2.54" 65mm 1,2,8 R3623 R3613 ba' (10mm) Small Orifice with Y" NPT R. Z Thread 2.8 40 2.54" 65mm 1,2,8 R3621 R3611 10mm Orifice XLH with RN" Thread 4.2 60 56.1mm 4,6,7 R3624 R3614 Conventional -Install in URright or Pendent Position 10mm Orifice XLH with R318 Thread 4.2 60 56.1mm R3674 15mm Standard Orifice with " NPT (R,'2) Thread 5.6 80 56.1mm 4,6,7 R3675 20mm Large Orifice with -3/4" NPTR3/•I Thread 8.0 115 58.4mm 4,7 R3672 Upright Pendent Upright Model F1 FR Quick Response Recessed Pendent. Sprinkler Installation Wrench: Model RC1 Sprinkler Wrench Installation Data: Conventional FNominal Orifice Thread Size K Factor Sprinkler Height Approval(" Organizations Sprinkler Identification Number (SIN) US Metric Y," (15mm) "' NPT (R'/2) 5.6 80 2.2" (56mm) 1,2,3,4,5,7,8 R3615 "/ " (20mm%" 32 NPT R'/� ( ) 8.0 115 2.3" (58mm) 1,2,3 R3612 (11 mm) y," NPT (R%2) 4.2 I 60 2.54" (65mm) 1,2,8 R3613 N" (10mm) ;'" NPT (R'/2) 2.8 40 2.54" (65mm) 1,2,8 R3611 10mm R% 4.2 60 56.1mm 4,7 R3614 "' Refer to escutcheon data table for approvals and dimensions. 1 17/Jj' M 171-2—) (36rw10 (1) RVTR r0 ESCUrCHCON DATA MOLE EOR APPROVALS AND DII/ENs0N1 2. S I/4' HOLE Dk (67-2--1 1 16/16- DA (49-2 m1 IX I/1 REDUCER IURN COLLAR UNIIL TCHr M.NNSI SPRINKLER {yRE)IG7 BOSS I WE OE %iKL CELR)C a 1 17/Jj' M 171-2—) (36rw10 (1) RVTR r0 ESCUrCHCON DATA MOLE EOR APPROVALS AND DII/ENs0N1 2. Model F1 FR Quick Response Vertical Sidewall Sprinkler Installation Wrench: Model D Sprinkler Wrench Installation Position: Upright or Pendent Approval Type: Light Hazard Occupancy Installation Data: Nominal Orifice Thread Size K Factor Sprinkler Height Approval Organizations Sprinkler Identification Number (SIN) us Metric ' /2" NPT (R'/2) 5.6 80 2.2" (56mm) 1, 2, 3, 6, 8 ;" (15mm) 15mm 112" NPT (R'/2) 5.6 80 2.2" (56mm) 4111 R3685 �') LPC Approval is for Pendent position only. Vertical Sidewall Orientation Deflector to Ceiling Dimension (Min. - Max.) Upright 4" - 12" 102mm - 305mM) Pendent 6" - 12" 152mm - 305mm Model F1 FR Quick Response Horizontal Sidewall Sprinkler Deflector: HSW 1 Installation Wrench: Model D Sprinkler Wrench Installation Data: NOTE: UL and ULC Listing permits use with F1 or F2 recessed escutcheon. b.. f�' k 2x 1l.1 Horizontal Sidewall 3. K Factor Approval Organizations and Type of Approval Sprinkler Identification us Metric Light Hazard Ordinary Hazard Nominal Orifice Thread Size SprinklerNumber Length (SIN) ;" (15mm) I y" NPT(R'/2) 5.6 80 2.63" (67mm) 1,2,3,5,8 1,2,5,8 R3635 NOTE: UL and ULC Listing permits use with F1 or F2 recessed escutcheon. b.. f�' k 2x 1l.1 Horizontal Sidewall 3. Installation Quick response sprinklers are intended for installation as specified in NFPA 13. Quick response sprinklers and standard response sprinklers should not be intermixed. The Model F1 FR Recessed Quick Response Sprinklers are to be installed as shown. The Model F1 or F2 Escutch- eons illustrated are the only recessed escutcheons to be used with the Model F1 FR Sprinklers. The use of any other recessed escutcheon will void all approvals and negate all warranties. When installing Model F1 FR Sprinklers, use the Model D Sprinkler Wrench. When installing Model F1 FR Recessed Sidewall Sprinklers, use the Model GFR1 Sprinkler Wrench. Use the Model RC 1 Wrench for installing F1 FR Recessed Pendent Sprinklers. Any other type of wrench may damage these sprinklers. Temperature Ratings Classification Sprinkler Temperature CF Max. Ambient Temp. Bulb Color Ordinary Ordinary Intermediate Intermediate High 111 57 68 79 93 i 141 135 155 175 200 286 100-F(38°C) 100°F (38°C) 150-F (66-C) 150`F(66°C) 1 225°F(107°C) Orange Rec Yeilow Green Blue (1) Not available for recessed sprinklers. Escutcheon Data —I Escutcheon IFace _ Escutcheon BronzeTC of Fitting - Modella�sion Approvals Adjushnent Painted tat to Ceiling or Sprinkler Escutcheon Bright Brass Bright Brass Wall Dimension - F1 1,2,4 X„ Off White Satin Chrome Satin Chrome 19mm 19mm 5mm-24mm F2 1,2,3,4,5,7 1,. °r_ 5., ,8 i (13mm (25mm) smm - 17mm yF FP 1,2 Fully Recessed j 1 1 mm Push -0N Thread -off — _ 1.2 Fully Retracted IK 24mm Maintenance The Models F1 FR and F1 FR Recessed Sprinklers should be inspected quarterly and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by using a soft brush or gen- tle vacuuming. Remove any sprinkler which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprin- klers. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used to mini- mize the potential for damage to sprinklers that would cause improper operation or non -operation. Sprinkler Types Standard Upright Standard Pendent Conventional Sidewall (Vertical, Horizontal HSW1) Recessed Pendent Recessed Horizontal Sidewall HSW 1 Finishes (111�) Standard Finishes Sprinkler _ Escutcheon BronzeTC rass Chrome Plated hrome Plated 131 White Polyester Coatedhite Painted tat Special Application Finishes Sprinkler Escutcheon Bright Brass Bright Brass Black Plated Black Plated Black Paint Black Paint Off White Off White Satin Chrome Satin Chrome (1) Other finishes and colors are available on special order. Consult the factory for details. (2) FM Approvals is limited to bronze and brass, chrome or black plated finishes only. (3) FP Push-on[Thread-off escutcheon Ordering Information Specify: 1. Sprinkler Model 2. Sprinkler Type 3. Orifice Size 4. Deflector Type 5. Temperature Rating 6. Sprinkler Finish 7. Escutcheon Type 8. Escutcheon Finish (where applicable) Note: When Model F1 FR Recessed sprinklers are ordered, the sprinklers and escutcheons are packaged separately. The equipment presented in this bulletin is to be installed in accordance with the latest pertinent Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting lile and property for over 80 years, and are installed and serviced by the most highly qualified and reputa- ble sprinkler contractors located throughout the United States, Canada and foreign countries. Manufactured by p Hefiab'lleIll. The Reliable Automatic Sprinkler Co., Inc. (800)431-1588 Sales Offices (800)848-6051 Sales Fax (914)668-3470 Corporate Offices www.rcliablesprinkler.com Internet Address Recycled Paper Revision lines indicate updated or new data EG. Prinlod in U.S.A. 3/00 PIN9999970027 The iron from which Class 125 'i cast iron fittings are made is held to` I strict formula by careful chemical 1 •analysis and control _ "1{ Tapping is done on the most ' modern types of threading machines'.' -All ' tappings -are to USA Standards for iron gl pipe threads:• Straightness and correct z ,,. depth of threads assured through; continuous• capable inspection, by, carefully -trained inspectors. Every fitting is hand'sorted and inspected to;eliminate`defective castings ,; WARD fittings are made toi',, specifications as published by the American National Standards Institute (ANSI) forr'pipe fittingm' They also a l ,.) conform toX. 'lJnited States FederalYL I Specifications. " 1 A chamfer is cut',or cast m ali, ' r - openings" permitting easy entrance of pipe and,dp'reventing damage`to,the first thread m handling and threading Because of the, close attention ' paid to formula-control'together withthe y ..use' Or modern precision;equipment=wee �± are able to„produce castings of rugged ! strength and ability to mjkq u' p tight -20 TO 150 175 2 "i 200 165 1 22 250 150 ssure a v ings A1NS1/ASME B 1F6 t for cast Iron X h a' z�S:r,'w 300 � ' s 350 �gk �`* �;a i°- •..": ... � =s Y '3 4,." , ti 400 ---- r s r NOTES: 1) Permissible for service temperature up to 353° F reflecting temperature of saturated The iron from which Class 125 'i cast iron fittings are made is held to` I strict formula by careful chemical 1 •analysis and control _ "1{ Tapping is done on the most ' modern types of threading machines'.' -All ' tappings -are to USA Standards for iron gl pipe threads:• Straightness and correct z ,,. depth of threads assured through; continuous• capable inspection, by, carefully -trained inspectors. Every fitting is hand'sorted and inspected to;eliminate`defective castings ,; WARD fittings are made toi',, specifications as published by the American National Standards Institute (ANSI) forr'pipe fittingm' They also a l ,.) conform toX. 'lJnited States FederalYL I Specifications. " 1 A chamfer is cut',or cast m ali, ' r - openings" permitting easy entrance of pipe and,dp'reventing damage`to,the first thread m handling and threading Because of the, close attention ' paid to formula-control'together withthe y ..use' Or modern precision;equipment=wee �± are able to„produce castings of rugged ! strength and ability to mjkq u' p tight -20 TO 150 175 2 "i 200 165 1 250 150 ssure a 3• ings A1NS1/ASME B 1F6 t for cast Iron N 300 140 {i 350 125 (see note 1) 4 z ifications UU." ULC�'AND.FrM where ali m6. ule. l 400 ---- a NOTES: 1) Permissible for service temperature up to 353° F reflecting temperature of saturated steam at 125 psig. .2) Permissible for service temperature up to 406° F reflecting temperature of saturated steam at 250 pslg. r. erial ,OSTM A126 Class A�Minimum for cast iron "i iensnsANSI B 16A 4;� ANSI B 1 20 itfor pipe threads w ssure a 3• ings A1NS1/ASME B 1F6 t for cast Iron tings: ASTM (ANSI) A'1 U for galv,anizIn"g - {i z ifications UU." ULC�'AND.FrM where ali m6. ule. l Federal 'specific ition`s`WWP501 a Sched.u1ew106/Schedu1em406 Fully Listed and FM Approved Sprinkler Pipe When you specify Schedule-10/Schedule-40 sprinkler pipe you get a UL listed and FM approved product. Although these products do not require separate approvals, Schedule-10/Schedule-40 gives you the extra quality assurance you demand. Our Sch-10 (IV,"- 8") pipe and Sch-40 (1 "- 2'/,") pipe have passed the same thorough lab testing as our other listed pipe products, and receive periodic mill inspections from both UL and FM agents to ensure consistent quality. Schedule-10/Schedule-40 product can be "hot -dip" galvanized to meet FM requirements for dry systems in accordance with the zinc coating specifications of ASTM A-123. Our advanced formula mill coating of- fers a clean, durable surface. It is also paint -ready for custom color applications Without special preparation. The internal surface of all black Allied Tube & Conduit Fire Sprinkler pipe . products up to 4.5000" in diameter is coated with our new Antibacterial For- mula, "ABF". In scientific laboratory test, ABS proved to have superior resis- tance to microbial colonization of pipe walls, thereby delaying or possibly pre- venting the onset of Microbiologically Influenced corrosion (MIC) when the First Sprinkler System is first installed. Meets "Buy American" requirement and is available through distributors in the USA, Canada and Mexico. Schedule-f0/Schedule-40 pipe are in compliance with the following: ASTM A-135, and NFPA 13. Both pipe products have a working pressure rating of 300 psi maximum and also meet the stringent requirement for the following tests: • Welded Outlets • Hydrostatic Pressure • Side Wali Rupture • Vibration Test tike/Flow Control Q allied TUBE & CONDUIT UL FM USC Listed Approved Listed 16100 S. Lathrop • Harvey, IL 60426 Customer Service: 11350 Norcom Rd. • Philadelphia, PA 19154 (800) 882-5543 NPS 7mm1n; Wt. Wt. (H20 Filled) Pcs/ Wt/Lift (21') WULiff (24') Wt/Lift (25') /n; mm In; mm Lbs/Ft; Kg/m Lbs/Ft; Kg/m Litt Lbs; Kg Lbs, Kg Lbs: Kg 1" 1.097 1.680 2.05 70 2,470 2,822 2,940 25 26.6 2.5 3.05 70 1,120 1,280 1,334 1'/<" 1.380 2.270 2.93 51 2,431 2,778 2,894 32 35.1 4.36 4.36 51 1,103 1,260 1,313 1'/z" 1.610 2.720 3.61 44 2,513 2,872 2,992 40 40.9 4.0 5.37 44 1,140 1,303 1,357 2" 2.067 3.650 5.13 30 2,300 2,628 2,738 50 52.5 5.4 7.63 30 1,043 1,192 1,242 2'/2" 2.469 5.790 7.86 19 2,310 2,640 2,750 65 62.7 8.6 11.73 19 1,048 1,197 1,247 tike/Flow Control Q allied TUBE & CONDUIT UL FM USC Listed Approved Listed 16100 S. Lathrop • Harvey, IL 60426 Customer Service: 11350 Norcom Rd. • Philadelphia, PA 19154 (800) 882-5543 NPS Nominal I.D. Wt. Wt. (H20 Filled) Pcs/ Wt/Lift (21') WULift (24') WULift (25') /n; mm In; mm Lbs/Ft, Kg/m Lbs/Ft; Kg/m Lilt Lbs; Kg Lbs; Kg Lbs; Kg 1" 1.097 1.400 1.81 91 2,675 3,053 3,185 25 27.9 2.1 2.70 91 1,213 1,385 1,445 1'/a" 1.442 1.810 2.52 61 2,319 2,664 2,760 32 36.6 2.7 3.75 61 1,052 1,208 1,252 1'/2" 1.682 2.080 3.04 61 2,664 3,045 3,172 40 42.7 3.1 4.52 61 1,208 1,381 1,439 2" 2.157 2.640 4.22 37 2,051 2,344 2,442 50 54.8 3.9 6.28 37 930 1,063 1,108 2'/2" 2.635 3.530 5.89 30 2,224 2,542 2,648 65 66.9 5.3 8.77 30 1,009 1,153 1,201 3" 3.260 4.330 7.94 19 1,728 1,975 2,057 80 82.8 6.4 11.82 19 784 896 933 4" 4.260 5.610 11.78 19 2,238 2,558 2,665 90 108.2 8.3 17.53 19 1,015 1,160 1,209 5" 5.295 7.77 17.33 10 1,632 1,865 1,943 125 134.5 11.56 25.80 10 740 846 881 6" 6.357 9.290 23.03 10 1,951 2,230 2,322 150 161.5 13.8 34.27 10 885 1,012 1,053 8" 8.249 16.490 40.15 7 2,424 2,770 2,885 200 209.5 24.5 59.75 7 1,100 1,256 1,309 tike/Flow Control Q allied TUBE & CONDUIT UL FM USC Listed Approved Listed 16100 S. Lathrop • Harvey, IL 60426 Customer Service: 11350 Norcom Rd. • Philadelphia, PA 19154 (800) 882-5543 2525 N. 27 th Ave. • Phoenix, AZ 85009 Fax 708-339-1806 S5-3 CAST IRON STRAIGHT 9 O 0 ELLS NPS Center to End A Outside Dia *of Band B min Thread Length D min Take Out Dimension 1/4" 0.810 0.930 0.320 0.435 3/8" 0.950 1.120 0.360 0.575 1/2" 1.120 1.340 0.430 0.558 3/4" 1.310 1.630 0.500 0.748 1" 1.500 1.950 0.580 0.813 11/4" 1.750 2.390 0.670 1.063 1 1/2" 1.940 2.680 0.700 1.253 2" 2.250 3.280 0.750 1.500 21/2" 2.700 3.860 0.920 1.763 3" 3.080 4.620 0.980 2.080 31/2" 3.420 5.200 1.030 2.358 4" 3.790 5.790 1.080 2.665 FIGURE 21 CAST IRON REDUCING 9 O 0 ELLS NPS Center to End X Center to End Z Outside Dia. of Band B1(min) Outside Dia. of Band B2(min) Length of Thread D1 (min) Length of Thread D2(min) Take Out Take Out 1/2 x 3/8" 1.120 1.120 1.340 1.340 0.430 0.360 0.745 0.620 3/4 x 1/2" 1.200 1.220 1.630 1.340 0.500 0.430 0.700 0.658 3/4 x 3/8" 1.200 1.220 1.630 1.340 0.500 0.360 0.825 0.658 1 x 3/4" 1.370 1.450 1.950 1.630 0.580 0.500 0.808 0.762 1 x 1/2" 1.260 1.360 1.950 1.340 0.580 0.430 0.760 0.672 1 1/4 x 1" 1.580 1.670 2.390 1.950 0.670 0.580 0.893 0.982 1 1/4 x 3/4" 1.450 1.620 2.390 1.630 0.670 0.500 0.888 0.933 1 1/4 x 1/2" 1.340 1.530 2.390 1.340 0.670 0.430 0.840 0.843 1 1/2 x 1 1/4" 1.820 1.880 2.680 2.390 0.700 0.670 1.133 1.193 1 1/2 x 1" 1.650 1.800 2.680 1.950 0.700 0.580 0.963 1.113 1 1/2 X 3/4" 1.520 1.750 2.680 1.630 0.700 0.500 0.958 1.063 1 1/2 x 1/2" 1.52.0 1.750 2.680 1.630 0.700 0.430 1.020 1.063 2 x 1 1/2" 2.020 2.160 3.280 2.680 0.750 0.700 1.333 1.410 2 x 1 1/4" 1.900 2.100 3.280 2.390 0.750 0.670 1.213 1.350 2 x 1" 1.730 2.020 3.280 1.950 0.750 0.580 1.043 1.270 2 X 3/4" 1.600 1.970 3.280 1.630 0.750 0.500 1.168 1.220 2 x 1/2" 1.600 1.970 3.280 1.630 0.750 0.430 1.100 1.220 2 1/2 x 2" 2.390 2.600 3.860 3.280 0.920 0.750 1.640 1.663 2 1/2 x 1 1/2" 2.160 2.510 3.860 2.680 0.920 0.700 1.473 1.573 2 1/2 X 1 1/4" 2.040 2.450 3.860 2.390 0.920 0.670 1.353 1.513 2 1/2 X 1" 1.870 2.370 3.860 1.950 0.920 0.580 1.183 1.433 2 1/2 x 3/4" 1.870 2.370 3.860 1.950 0.920 0.500 1.308 1.433 3 x 2 1/2" 2.830 2.990 4.620 3.860 0.980 0.920 1.893 1.990 3 x 2" 2.520 2.890 4.620 3.280 0.980 0.750 1.770 1.890 3 x 1 1/2" 2.520 2.890 4.620 3.280 0.980 0.700 1.833 1.890 .3X1 1/4 " 2.170 2.740 4.620 2.390 0.980 0.670 1.483 1.740 3 x 1" 2.170 2.740 4.620 2.390 0.980 0.580 1 1.483 1.740 3 1/2 x 3" 3.420 3.420 5.200 5.200 1.030 0.980 2.420 2.358 4 x 3 1/2" 3.540 3.690 5.790 5.200 1.080 1.030 2.478 2.565 4 x 3" 3.300 3.600 5.790 4.620 1.080 0.980 2.300 2.475 4 x 2 1/2" 3.300 3.600 5.790 4.620 1.080 0.920 2.363 2.475 4 x 2" 1 2.740 3.410 5.790 3.280 1 1.080 0.750 1.990 2.285 4 x 1 1/2" 2.740 3.410 5.790 3.280 1 1.080 1 0.700 2.053 2.285 FIGURE 22 31 CAST IRON 4 5 0 ELLS NPS Center to End A Outside Dia. of Band B min Length of Thread C min Take Out 1/2" 0.880 1.340 0.430 0.380 3/4" 0.980 1.630 0.500 0.418 1" 1.120 1.950 0.580 0.433 1 1/4" 1.290 2.390 0.670 0.603 1 1/2" 1.430 2.680 0.700 0.743 2" 1.680 3.280 0.750 0.930 2 1/2" 1.950 3.860 0.920 1.013 3" 2.170 4.620 0.980 1 1.170 31/2" 2.390 5.200 1.030 1.328 4" 1 2.610 5.790 1.080 1.485 CAST IRON STRAIGHT TEES NPS Center to End A Outside Dia. of Band B min Thread Length D min Take Out Dim. 3/8" 0.950 1.120 0.360 0.575 1/2" 1.120 1.340 0.430 0.620 3/4" 1.310 1.630 0.500 0.748 1 " 1.500 1.950 0.580 0.813 11/4" 1.750 2.390 0.670 1.063 11/2" 1.940 2.680 0.700 1.253 2" 2.250 3.280 0.750 1.500 2 1/2" 2.700 1 3.860 0.920 1.763 3" 3.080 4.620 0.980 2.080 3 1/2" 3.420 5.200 1.030 2.358 4" 3.790 5.790 1.080 2.665 FIGURE 23 FIGURE 24 _.., .., ,�;,�,w �...:, --'. .: s_ x �" ..tr yw•tcraN!;,, vA. �./r;-s?;, .. �xk�95,t�.�Za{ r."o't�zh�e�k°c�..G�wiCeti.:�.�-r��irax�k:�i'Nr.'�'ir,�+�ji^aa"�r±ti �tl�i�J.�at:aaw,.,r.... 32 CAST IRON REDUCING TEES r82 --I I --A3 j D2 W D3 i - - B3 Al ` D1 FIGURE 25 NPS H denotes Heel Ell Center To End Al Center To End A 2 Center To End A 3 ;ia. Outside Dia. of Band B 2 min Outside Dia. of Band B 3 min Thread Length D1 min Thread Length D2 min Thread Length D3 min1/2 Take Out Take Out Take Out x 1/2 x 3/8 1.120 1.120 1.120 1.340 1.340 0.430 0.430 0.360 0.620 0.520 0.745 1/2 x 3/8 x 1/2 1.120 1.120 1.120 1.340 1.340 0.430 0.360 0.430 0.620 0.745 0.620 1/2 x 3/8 x 3/8 1.120 1.120 1.120 1.340 1.340 1.340 0.430 0.360 0.360 0.620 0.745 0.745 3/8 x 3/8 x 1/2 1 1.120 1 1.120 1.120 1.340 1 1.340 1.340 0.360 0.360 0.430 0.745 0.745 0.620 3/4 x 3/4 x 1/2 1.200 1.200 1.220 1.630 1.630 1.340 0.500 1 0.500 0.430 1 0.638 0.638 0.720 3/4 x 3/4 x 3/8 1.200 1.200 1.220 1.630 1.630 1.340 0.500 1 0.500 0.360 0.638 0.638 0.845 3/4 x 1/2 x 3/4 1.310 1.310 1.310 1.630 1.630 1.630 0.500 0.430 0.500 0.748 0.810 0.748 3/4 x 1/2 x 1/2 1.200 1.120 1.220 1.630 1.340 1.340 0.500 0.430 0.430 0.638 0.620 0.720 1/2 x 1/2 x 3/4 1.310 1.310 1.310 1.630 1.630 1.630 0.430 0.430 0.500 0.810 0.810 0.748 1 x 1 x 3/4 1.370 1.370 1.450 1.950 1.950 1.630 0.580 0.580 0.500 0.683 0.763 0.888 1 x 1 x 1/2 1.260 1.260 1.360 1.950 1.950 1.340 0.580 0.580 0.430 0.573 0.673 0.860 1 x 1 x 3/8 1.260 1.260 1.360 1.950 1.950 1.340 0.580 0.580 0.360 0.573 0.673 0.985 1 x 3/8 x 1 1.500 1.360 1.500 1.950 1.340 1.950 0.580 0.360 0.580 0.813 0.985 0.813 1 x 3/4 x 1 1.500 1.450 1.500 1.950 1.630 1.950 0.580 0.500 0.580 0.813 0.888 0.813 1 x 3/4 x 3/4 1.370 1.310 1.450 1.950 1.630 1.630 0.580 0.500 0.500 0.683 0.748 0.888 1 x 3/4 x 1/2 1.260 1.260 1.360 1.950 1.950 1.340 0.580 0.500 0.430 0.573 0.698 0.860 1 x 1/2 x 1 1.500 1.360 1.500 1.950 1.340 1.950 0.580 0.430 0.580 0.813 0.860 0.813 1 x 1/2 x 3/4 1.370 1.310 1.450 1.950 1.630 1.630 0.580 0.430 0.500 0.683 0.810 0.888 1 x 1/2 x 1/2 1.260 1.120 1.360 1.950 1.340 1.340 0.580 0.430 0.430 0.573 0.620 0.860 1 x 1/4 x 1 1.500 1.200 1.500 1.950 0.930 1.950 0.580 0.320 0.580 0.813 0.825 0.813 3/4 x 3/4 x 1 1.500 1.450 1.500 1.950 1.630 1.950 0.500 0.500 0.580 0.938 0.888 0.813 3/4 x 1/2 x 1 1.500 1.360 1.500 1.950 1.340 1.950 0.500 0.500 0.580 0.938 0.860 0.813 1 1/4 x 1 1/4 x 1 1.580 1.580 1.670 2.390 2.390 1.950 0.670 0.670 0.580 0.893 0.893 0.983 1 1/4 x 1 1/4 x 3/4 1.450 1.450 1.620 2.390 2.390 1.630 0.670 0.670 0.500 0.763 0.763 1.058 1 1/4 x 1 1/4 x 1/2 1.340 1.340 1.530 2.390 2.390 1.340 0.670 0.670 0.430 0.653 0.653 1.030 1 1/4 x 1 x 1 1/4 1.750 1.670 1.750 2.390 1.950 2.390 0.670 0.580 0.670 1.063 0.983 1.063 1 1/4 x 1 x 1 1.580 1.500 1.670 2.390 1.950 1.950 0.670 0.580 0.580 0.893 0.813 0.983 1 1/4 x 1 x 3/4 1.450 1.370 1.620 2.390 1.950 1.630 0.670 0.580 0.500 0.763 0.683 1.058 1 1/4 x 1 x 1/2 1.340 1.260 1.530 2.390 1.950 1.340 0.670 0.580 0.430 0.653 0.573 1.030 1 1/4 x 3/4 x 1 1/4 1.750 1.620 1.750 2.390 1.630 2.390 0.670 0.500 0.670 1.063 1.058 1.063 1 1/4 x 3/4 x 1 1.580 1.450 1.670 2.390 1.630 1.950 0.670 0.500 0.580 0.893 0.888 0.983 1 1/4 x3/4 x 3/4 1.450 1.310 1.620 2.390 1.630 1.630 0.670 0.500 0.500 0.763 0.748 1.058 1 1/4 x 3/4 x 1/2 1.450 1.310 1.620 2.390 1.630 1.630 0.670 0.500 0.430 0.763 0.748 1.120 1 1/4 x 1/2 x 1 1/4 1.750 1.530 1.750 2.390 1.340 2.390 0.670 0.430 0.670 1.063 1.030 1.063 1 1/4 x 1/2 x 1 1.750 1.530 1.750 2.390 1.340 2.390 0.670 0.430 0.580 1.063 1.030 1.063 1 1/4 x 1/2 x 3/8 1.580 1.450 1.450 2.390 1.340 1.120 0.670 0.430 0.360 0.893 0.950 -1.075 1 1/4 x 1/2 x 1/2 1.340- 1.120 1.530 2.390 1.340 1.340 0.670 0.430 0.430 0.653 0.620 1.030 1 1/4 x 1/2 x 3/4 1.450 1.310 1.620 2.390 1.630 1.630 0.670 0.430 0.500 0.763 0.810 1.058 1 1/4 x 1/4 x 1 1/4 H 1.750 1.530 1.750 2.390 0.930 2.390 0.670 0.320 0.670 1.063 1.155 1.063 1 1/4 x 1/8 x 1 :1 /4 H 1.750 1.530 1.750 2.390 0.810 2.390 0.670 0.320 0.670 1.063 1.280 1.063 1 x 1 x 1 1/4 1.750 1.620 1.750 2.390 1.630 2.390 0.580 0.580 0.670 1.063 0.983 1.063 1 x 3/4 x 1 1/4 1.750 1.620 1.750 2.390 1.630 2.390 0.580 0.500 0.670 1.063 1.058 1.063 1 x 112 x 1 1/4 1 1.750 1.530 1.750 2.390 1.340 2.390 0.580 0.430 0.670 1.063 1.030 1.063 1 1/2 x 1 1/2 x 1 1.820 1.820 1.880 2.680 2.680 2.390 0.700 0.700 0.670 1.133 1.133 1.193 1 1/2 x 1 1/2 x 1 1.650 1.650 1.800 2.680 2.680 1.950 0.700 0.700 0.580 0.963 0.963 1.113 1 1/2 x 1 1/2 x 3/4 1.520 1.520 1.750 2.680 2.680 1.630 0.700 0.700 0.500 0.833 0.833 1.188 1 1/2 x 1 1/2 x 1/2 1.410 1.410 1.660 2.680 2.680 1.340 0.700 0.700 0.430 0.723 0.723 1.160 1 1/2 x 1 1/2 x 3/8 1.410 1.410 1.660 2.680 2.680 1.340 0.700 0.700 0.360 0.723 0.723 1.285 1 1/2 x 1 1/4 x 1 1.940 1.880 1.940 1 2.680 1 2.390 2.680 0.700 0.670 0.670 1.253 1.193 1.253 1 1/2 x 1 1/4 x 1 1.820 1.750 1 1.880 1 2.680 1 2.390 2.390 0.700 0.670 1 0.670 1.133 1.063 1.193 33 CAST IRON REDUCING TEES rBz--I �-- A3 D2 D3 Al T- --I t- - - B3 10 Al - 1.._ D1 34 FIGURE 25 NPS H denotes Heel Ell Center To End Al Center To End A 2 Center To End A 3 Outside Dia. of Band B 1 min Outside Dia. of Band B 2 min Outside Dia. of Band B 3 min Thread Length D 1 min Thread Length D 2 min Thread Length D 3(min) Take Out Take Out Take Out 1 1/2 x 1 1/4 x 1 1.650 1.580 1.800 2.680 2.390 1.950 0.700 0.670 0.580 0.963 0.893 1.113 1 1/2 x 1 1/4 X 3/4 1.520 1.450 1.750 2.680 2.390 1.630 0.700 0.670 0.500 0.833 0.763 1.188 1 1/2 x 1 1/4 x 1/2 1 1/2 x 1 x 1 1/2 1 1.410 1.940 1 1.340 1.880 1.660 1.940 2.680 2.680 2.390 1.950 1.340 2.680 0.700 0.700 0.670 0.580 0.430 0.700 0.723 1.253 0.653 1.113 1.160- 1.253 i 1/2 x 1 x 1 1/4 1.940 1.800 1.940 2.680 1.950 2.680 0.700 0.580 0.670 1.253 1.113 1.253 i 1/2 x 1 x 1 1 1/2 x 1 x 3/4 1.650 1.650 1.500 1.500 1.800 1.800 2.680 2.680 1.950 1.950 1.950 1.950 0.700 0.700 0.580 0.580 0.580 0.500 0.963 0.963 0.813 0.813 1.113 1.238 1 1/2 x 1 x 1/2 1.410 1.340 1.660 2.680 2.390 1.340 0.700 0.580 0.430 0.723 0.653 1.160 1 1/2 x 3/4 x 1 1/2 1.940 1.750 1.940 2.680 1.630 2.680 0.700 0.500 0.700 1.253 1.188 1.253 1 1/2 x 3/4 x 1 1/4 1 1.940 1 1.750 1.940 2.680 1.630 2.680 0.700 0.500 0.670 1.253 1.188 1.253 1 1/2 x 3/4 x 1 1.650 1 1.500 1.800 1 2.680 1.950 1.950 0.700 0.500 0.580 0.963 0.938 1.113 1 1/2 x 3/4 x 3/4 1.650 1 1.500 1.800 1 2.680 1.630 1.630 0.700 0.500 0.500 0.963 0.938 1.238 1 1/2 x 3/4 x 1/2 1.525 1 1.375 1.800 2.680 1.630 1.630 0.700 0.500 0.430 0.838 0.813 1.300 1 1/2 x 1/2 x 1 1/2 1.940 1.660 1.940 2.680 1.340 2.680 0.700 0.430 0.700 1.253 1.160 1.253 1 1/2 x 1/2 x 1 1/4 1.940 1.660 1.94a 2.680 1.340 2.680 0.700 0.430 1 0.670 1.253 1.160 1.253 "1 1/2 x 1/2 x 3/4 1.525 1.375 1.800 2.680 1.630 1.630 0.700 0.430 0.500 0.8381 0.875 1.238 1 1/2 x 1/2 x 1/2 1.525 1.375 1.800 2.680 1.630 1.630 0.700 0.430 0.430 0.838 0.875 1.300 1 114 x 1 1/4 x 1 1/2 1.940 1.880 1.940 2.680 2.390 2.680 0.670 0.670 0.700 1.253 1.193 1.253 1 1/4 x 1 x 1 1/2 1.940 1.800 1.940 2.680 1.950 2.680 0.670 0.580 0.700 1.253 1.113 1.253 1 1/4 x 3/4 x 1 1/2 1.940 1.750 1.940 2.680 1.630 2.680 0.670 0.500 0.700 1.253 1.188 1.253 1 1/4 x 1/2 x 1 1/2 1.940 1.660 1.940 2.680 1.340 2.680 0.670 0.430 0.700 1.253 0.973 1.253 2 x 2 x 11/2 2.020 2.020 2.160 3.280 3.280 2.680 0.750 0.750 0.700 1.270 1.270 1.473 2 x 2 x 1 1/4 1.900 1.900 2.100 3.280 3.280 2.390 0.750 0.750 0.670 1.150 1.150 1.413 2 x 2 x 1 2 x 2 x 3/4 2 x 2 x 1/2 1.730 1.600 1.490 1 1.730 1.600 1.490 2.020 1.970 1.880 3.280 3.280 3.280 3.280 3.280 3.280 1.950 1.630 1.340 0.750 0.750 0.750 0.750 0.750 0.750 0.580 0.500 0.430 0.980 0.850 0.740 0.980 0.850 0.740 1.333 1.408 1.380 2x 1 1/2 x 2 2 x 1 1/2 x 1 1/2 2.250 1 2.020 2.160 1.940 2.250 2.160 3.280 3.280 2.680 2.680 3.280 2.680 0.750 0.750 0.700 0.700 0.750 0.700 1.500 1.270 1.473 1.253 1.500 1.473 2 x 1 1/2 x 1 1/4 2.020 1 1.940 2.160 3.280 2.680 2.680 0.750 0.700 0.670 1.270 1.253 1.473 2 x 1 1/2 x 1 1.730 1.650 2.020 3.280 2.680 1.950 0.750 0.700 0.670 0.980 0.963 1.333 2 x 1 1/2 x 3/4 1.600 1.520 1.970 3.280 2.680 1.630 0.750 0.700 0.500 0.850 0.833 1.408 2 x 1 1/2 x 1/2 1.490 1.410 1.880 3.280 2.680 1.340 0.750 0.700 0.430 0.740 0.723 1.380 2 x 1 1/4x2 2 x 1 1/4 x 1 112 2.250 2.020 2.100 1.940 2.250 2.160 3.280 3.280 2.390 2.680 3.280 2.680 0.750 0.750 0.670 0.670 0.750 0.700 1.500 1.270 1.413 1.253 1.500 1.473 2 x 1 1/4 x 1 1/4 1.900 1.750 2.100 3.280 2.390 2.390 0.750 0.670 0.670 1.150 1.063 1.413 2 x 1 1/4 x 1 2 x 1 1/4 x 1/2 1.900 1 1.490 1 1.750 1.410 2.100 1.880 3.280 3.280 2.390 2.680 2.390 1.340 0.750 0.750 0.670 0.670 0.580 0.430 1.150 0.740 1.063 0.723 1.413 1.380 2 x 1 x 2 2.250 2.020 2.250 1 3.280 1.950 3.280 0.750 0.580 0.750 1.500 1.333 1.500 2 x 1 x 1 1/2 -1x 2.250 2.020 2.250 1 3.280 1.950 3.280 0.750 0.580 0.700 1.500 1.333 1.563 2 T 1 1/4 1.900 1.750 2.100 1 3.280 2.390 2.390 0.750 0.580 0.670 1.150 1.063 1.413 2 x 1 x 1 •1.730 1.940 2.020 1 3.280 1.950 1.950 0.750 0.580 0.580 0.980 1.253 1.333 2 x 1 x 3/4 1.730 1.940 2.020 3.280 1.950 1 1.950 0.750 0.580 0.500 0.980 1.253 1.458 2 x 3/4 x 2 2.250 1.970 2.250 3.280 1.630 1 3.280 0.750 0.500 0.750 1.500 1.408 1.500 2 x 3/4 x 1 1/2 H 2.250 1.970 2.250 3.280 1.630 3.280 0.750 0.500 0.700 1.500 1.408 1.563 2 x 3/4 x 1 1/4 2.250 1.970 2.250 3.280 1.630 3.280 0.750 0.500 0.670 1.500 1.408 1.563 2 x 3/4 x 1 1.730 1.940 2.020 3.280 1.950 1.950 0.750 0.500 0.580 0.980 1.378 1.333 2 x 3/4 x 3/4 1.600 1.600 1.970 3.280 1.630 1.630 0.750 0.500 0.500 0.850 1.038 1.408 2 x 314 x 1/2 1.600 1.600 1.970 3.280 1.630 1.630 0.750 0.500 0.500 0.850 1.038 1.470 2x 1/2x2 2.250 1:880 2.250 3.280 1.340 3.280 0.750 0.430 0.750 1.500 1.380 1.500 2 x 1/2 x 1 1/2 2.020 t.660 2.160 3.280 1.340-T 2.680 1 0.750 0.430 0.700 1 1.270 1.160 1.473 CAST IRON REDUCING TEES �B2---I f --A3 02 -' D3 - AIZ - - 83 All I - LD1no_ FIGURE 25 NPS Center Center Center Outside Outside Outside Thread Thread Thread Take Take Take To End To End To End Dia. Dia. Dia. Length Length Length H denotes Heel Ell of Band of Band of Band Out Out Out Al A2 A3 131(min) 132(min) 63(min) D1 (min) D2(min) D3(min) 2 x 1/2 x 1 114 1.730 1.730 2.020 3.280 1.340 2.680 0.750 0.430 0.670 1.270- 1.160 1.473 2 x 1/2 x 3/4 1.600 1.600 1.970 3.280 1.630 1.630 0.750 0.430 0.500 0.850 1.100 1.408 2 x 1/2 x 1/2 1.600 1.600 1 1.970 3.280 1 1.630 1.630 0.750 0.430 0.430 0.850 1.100 1 1.470 1 1/2 x 1 1/2 x 2 1 2.160 2.160 2.020 2.680 2.680 3.280 0.700 0.700 0.750 1.473 1.473 1.270 1 1/2 x 1 1/4 x 2 2.250 2.100 2.250 3.280 2.390 3.280 0.700 0.670 0.750 1.563 1.413 1.500 1 1/2 x 1 x 2 2.250 2.020 2.250 3.280 1.950 3.280 0.700 0.580 0.750 1.563 1.333 1.500 2 1/2 x 2 1/2 x 2 2.390 2.390 2.600 3.860 3.860 3.280 0.920 0.920 0.750 1.453 1.453 1.850 2 1/2 x 2 1/2 x 1 1/2 2.160 2.160 2.510 3.860 3.860 2.680 0.920 0.9200.700 1.223 1.223 1.823 2 1/2 x 2 1/2 x 1 1/4 2.040 2040. 2.450 3.860 3.860 2.390 0.920 0.920 0.670 1.103 1.103 1.763 2 1/2 x 2 1/2 x 1 1.870 1.870 2.370 3.860 3.860 1.950 0.920 1 0.920 0.580 0.933 0.933 1.683 2 1/2 x 2 1/2 x 3/4 1 1.870 1.870 2.370 3.860 3.860 1.950 0.920 0.920 0.500 0.933 0.933 1.808 2 1/2 x 2 1/2 x 1/2 1 1.870 1.870 2.370 3.860 3.860 1.950 0.920 1 0.920 0.430 0.933 0.933 1.870 2 1/2 x 2 x 2 1/2 2.700 2.600 2.700 3.860 3.280 3.860 0.920 0.750 0.920 1.763 1.850 1.763 2 1/2 x 2 x 2 2.390 2.250 2.600 3.860 3.280 3.280 0.920 0.750 0.750 1.453 1.500 1.850 2 1/2 x 2 x 1 1/2 2.390 2.250 2.600 3.860 3.280 3.280 0.920 0.750 0.700 1.453 1.500 1.913 2 1/2 x 2 x 1 1/4 2.040 1.900 2.450 3.860 3.280 2.390 0.920 0.750 0.670 1.103 1.150 1.763 2 1/2 x 2 x 1 2.040 1.900 2.450 3.860 3.280 2.390 0.920 0.750 0.580 1.103 1.150 1.763 2 1/2 x 2 x 3/4 1.870 1.870 2.370 3.860 3.860 1.950 0.920 0.750 0.580 0.933 1.120 1.808 2 1/2 x 2 x 1/2 1.630 1.490 2.230 3.860 3.280 1.340 0.920 0.750 0.430 0.693 0.740 1.730 2 1/2 x 1 1/2 x 2 112 2.700 2.510 2.700 3.860 2.680 3.860 0.920 0.700 0.920 1.763 1.823 1.763 2 1/2 x 1 1/2 x 2 2.390 2.250 2.600 3.860 3.280 3.280 0.920 0.750 0.750 1.453 1.563 1.850 2 1/2 x 1 1/2 x 1 1/2 2.160 1.940 2.510 3.860 2.680 2.680 0.920 0.700 0.700 1.223 1.253 1.823 2 1/2 x 1 1/2 x 1 114 2.040 1.900 2.450 3.860 3.280 2.390 0.920 0.700 0.670 1 1.103 1.213 1.763 2 1/2 x 1 1/2 x 1/2 1.630 1.490 2.230 3.860 3.280 1.340 10.920 1 0.700 0.430 1 0.693 0.803 1.730 2 1/2 x 1 1/4 x 2 1/2 2.700 2.450 2.700 3.860 2.390 3.860 0.920 0.670 0.920 1 1.763 1.763 1.763 2 1/2 x 1 1/4 x 2 2.700 2.450 2.700 3.860 2.390 3.860 0.920 0.670 0.750 1.763 1.763 1.950 2 1/2 x 1 1/4 x 1 1/2 2.160 1.940 2.510 3.860 2.680 2.680 0.920 0.670 0.700 1.223 1.253 1.823 2 1/2 x 1 1/4 x 1 1/4 2.040 1.900 2.450 3.860 2.390 2.390 0.920 0.670 0.670 1.103 1.213 1.763 2 1/2 x 1 1/4 x 1 2.140 2.120 2.510 3.860 2.390 2.390 0.920 0.670 0.580 1.203 1.433 1.823 2 1/2 x 1 x 2 1/2 2.700 2.450 2.700 3.860 2.390 3.860 0.920 0.580 0.920 1.763 1.763 1.763 2 1/2 x 1 x 2 2.700 2.450 2.700 3.860 2.390 3.860 0.920 0.580 0.700 1.763 1.763 1.950 2 1/2 x 1,x 1 1/4 2.140 2.120 1 2.510 3.860 2.390 2.390 0.920 0.580 0.670 1.203 1.433 1.823 2 1/2 x 1 x 1 1.940 1.750 2.370 3.860 1.950 1.950 0.920 0.580 0.580 1.003 1 1.063 1.683 2 1/2 x 1 x 3/4 1.940 1 1.750 2.370 3.860 1 1.950 1.950 0.920 0.580 0.500 1.003 1.063 1.808 2 1/2 x 3/4 x 2 1/2 2.700 2.320 2.700 3.860 1 1.630 3.860 0.920 0.500 0.920 1.763 1.758 1.763 2 1/2 x 3/4 x 2 H 2.700 2.320 2.700 3.860 1.630 3.860 0.920 0.500 0.750 1.763 1.758 1.950 2 1/2 x 3/4 x 1 1.940 1.750 2.370 3.860 1.950 1.950 0.920 0.500 0.580 1.003 1.188 1.683 2 112 x 3/4 x 3/4 1.940 1.750 2.370 3.860 1.950 1.950 0.920 0.500 0.500 1.003 1.188 1.808 2 1/2 x 1/2 x 2 1/2 H 2.700 2.230 2.700 3.860 1.340 3.860 0.920 0.430 0.920 1.763 1.730 1.763 2 1/2 x 1/2 x 2 H 2.700 2.600 2.700 3.860 1.340 3.860 0.920 0.430 0.750 1.763 2.100 1.950 2 x 2 x 2 1/2 2.600 2.600 2.390 3.280 3.280 3.860 0.750 0.750 0.920 1.850 1.850 1.453 2 x 1 1/2 x 2 1/2 1 2.600 2.600 2.390 3.280 1 3.280 3.860 0.750 0.700 0.920 1.850 1.913 1.453 2 x 1 1/4 x 2 1/2 2.700 2.450 2.700 3.860 1 2.390 3.860 0.750 0.670 0.920 1.950 1.763 1.763 2 x 1 x 2 1/2 2.700 2.450 2.700 3.860-1-2.390 3.860 0.750 0.580 0.920 1.950 1.763 1.763 2 x 3/4 x 2 1/2 H 2.700 2.320 2.700 3.860 1 1.630 3.860 0.750 0.500 0.920 1.950 1.758 1.763 1 1/2 x 1 1/2 x 2 1/2 2.510 2.510 2.160 2.680 2.680 3.860 0.700 0.700 0.920 1.823 1.823 1.223 3 x 3 x 2 1/2 2.830 2.830 2.990 4.620 4.620 3.860 0.980 0.980 0.920 1.830 1.830 2.053 3 x 3 x 2 2.52(L 2.520 2.890 4.620 4.620 3.280 0.980 0.980 0.750 1.520 1.520 2.140 3 x 3 x 1 1/2 2.520 2.520 2.890 4.620 4.620 3.280 0.980 0.980 0.700 1.520 1.520 2.203 3 x 3 x 1 1/4 2.170 2.170 2.740 4.620 4.620 ?_.390 0.980 0.980 0.670 1.170 1.170 2.053 35 i cta i An ilio; 9001 certifled company 202-1.4_�.,' PRODUCT DES CRIPTION FireLockr" Style 005 rigid coupling has a unique, pat- ented angle -pad design which allows the housings to offset while clamping the grooves. By permitting the housings to slide on the angled bolt pads, rigidity is obtained. Patented DIMENSIONS Rated for wet and dry sprinkler systems at 350 PSI (2413 kPa) for 1'/4 - 4" (42,4 - 114.3 mm) sizes and 300 PSI (2068 kPa) for 4'/4 - 8.. (108,0 - 219,1 mm) sizes: Schedule 10 roll grooved or Schedule 40 cut or roll grooved steel pipe. Style 005 is rigid and does not accommodate expan- sion, contraction or angular deflection. The FireLock couplings provide rigidity for valve connections, fire mains and long straight runs. Support and hanging requirements correspond to NFPA 13 Style 005 Vic lug ireL.ocl�TI Gasket System Rigid Coupling with Vic-PIusTM Gasket System Sprinkler Systems. Angle - pad design permits assem bly by removing one nut/ bolt and swinging the housing over the gasket. This reduces components to handle during assembly speeds and eases installa- tion on pipe grooved to Victaulic specifications. Style 005 FireLock cou- plings with the Vic - Plus" Gasket System are designed and rec- ommended for use ,'u Cl�GI IRE §LPC and VdS Approved, see notes on page 2 ONLY on fire protection systems. Vic -Plus Gasket System: Victaulic® now offers a gas- ket system which requires no field lubrication. The Vic -Plus"' System (patent pending) is dry, clean, and non-toxic. It reduces assembly time substantially and eliminates the mess and chance of over -lubrication. .Mv i SIZE Max. Max. Allow. Dimensions Nominal Work. End Pipe End @ Bolt/Nut Inches/ in Aprx. Inches Press. § Load Sep. t No. - Size Wgt. Ea. PSI'h,P;i Lbs.'/;,, ln.[r. r. Inches/m, X Y Z Lbs./­ bs /s,:., 1 1Y4 350 755 0,05 2.75 4.50 1.88 1.2 3/e X 2 1'/2 350 990 0.05 2 -'/8 X 2 3.00 4.75 1.88 1.2 2 350 1550 0.07 3.50 5.25 1.88 1.6 . 2 - 3/8 X 21/2 2'/2 350 2270 0.07 430 5.75 1.88 1.9 2 '/e X 2'/z 76,1 mm 350 2475 0.07 2 - 3/8 X 2'/z 4.13 5.75 1.88 1.9 3 350 3365 0,07 4.63 6.13 1.88 2.1 2 3/E X 2Y2 4 01. 5565 0.16 5.75 7.25 2.13 3.1 2 _'/e X 2Y2 108,0 mm 300 4255 0.16 2 - 3/8 X 2'/2 5.63 7.25 2.13 3.1 5 300 7290 0.16 6.88 9.00 2.13 4.5 2 '/z x 23/, 133,0 mm 300 6495 0.16 2 1/2 X 23/4 6.63 9.00 2.13 4.5 139,7 mm 300 7125 0.16 2 -'/z X 2Y. 6.88 - 9.00 2.13 4.8 6 300 10340 0.16 8.00 10.00 2.13 5.0 , ..: ... , 2 - '/z x 23/4 ... 159,0 mm 300 9200 0.16 2 - s/s X 4'/a 7.63 , 10,00 2.13 5.5 165,1 mm 300 9955 0.16 2 - '/z X 2Ya 8.15 10.00 2.13 5.5 8 300 17525 0.19 10.50 13.13 2.63 11.3 , L. 2 - 5/8 x 4'n ® § t Hofer to notes on page 2, Victaulic' World Headquarlers • P.O. Box 31, Easton, PA 18044-0031 •4901 KessIersviIIe Rd., Easton, PA 18040. 1 -800 -PICK V1 • FAX: 610/250-8817 • www.viclauIic.com 1538 Rev.E 10/00 a Registered rradomark of Viclaulic 0 copyright 1999 Viclaulic Printed m US A. CAST IRON PIPE CAPS FIGURE 30. NPS Outside Diameter A min Overall Height B Thread Length C min 2 1/2" 3.860 1.810 0.920 3" 4.620 1.910 0.980 31/2" 5.200 2.030 1.030 4" 5.790 2.220 1.080 5" 7.050 2.38 1 1.180 6" 8.280 2.630 1 1.280 CAST IRON CROSS ' B A FIGURE 3 O A NJ NPS Center to End A Outside Dia. Band B min Length of Thread D min Metal Thickness E Take Out Dimension 1/2" 1.250 1.340 0.430 0.160 0.820 3/4" 1.440 1.630 0.500 0.180 0.940 1 " 1.630 1.950 0.580 0.200 1.050 1 1/4" 1.940 1i 2.390 0.670 0.220 1.270 11/2" 2.130 2.680 0.700 0.240 1.430 2" 2.500 3.280 1.750 0.260 1.750 38 ',fli4'!�+ii.'3!'✓\Sk4i..."wR.ri'?J�"`i:$5'itEzr'�r`.'s�.'tii+rJ`1f-��hi".� Housing: Ductile iron conform- ing to ASTM A-395, grade 65- 45-15, and ASTM A-536, grade 65-45-12. Housing Coating: Orange enamel U Optional: Hot dipped galva- nized Gasket: Cl Grade "E" EPDM - Type A Vic -Plus Gasket System t (Violet color code). FireLock products have been Listed by Underwriters Laboratories Inc. and Approved by Factory Mutual Research for wet and dry (oil free air) sprinkler ser- vices up to the rated working pressure using the Grade '•E•• Type A Vic -Plus Gasket System, requiring no field lubrication. For dry services, Victaulic continues to recommend the use of Grade "E" Type A FlushSeal'' Vic -Plus Gasket System. Contact Victaulic for details. Bolts/Nuts: Heat treated car- bon steel, zinc electroplated to ASTM B-633; Track head bolt conforming to ASTM A-183 minimum tensile 110,000 PSI (758340 kPa); Flanged hex nut conforming to ASTM A-563, Grade A. t Standard gasket and FlushSeal gasket approved for dry pipe systems to -40°F (-X10°C). Supplemental lubricant is rec- ommended for services installed at or continuously operating below 0°F (-18°C). Victaulic continues to recom- mend the use of FlushSeal gaskets for dry services. The information provided below is based on the latest listing and approval data at the time of publication. Listings/Approvals are subject to change and/or additions by the approvals agencies. Contact Victaulic for performance on other pipe and the latest listings and approvals. 10.02 2A NOTES: 5 refers to Listed/Approved Schedule 5 steel sprinkler pipe 10 refers to Listed/Approved Schedule 10 steel sprinkler pipe. 40 refers to Listed/Approved Schedule 40 steel sprinkler pipe. BLT refers to Listed/Approved steel sprinkler pipe manufactured by American Tube Company. DF refers to Listed/Approved Dyna -Flow steel sprinkler pipe manufactured by American Tube Company. DT refers to Listed/Approved Dyna Thread steel sprinkler pipe manufactured by American Tube Company. EL refers to Listed/Approved Eddylite steel sprinkler pipe manufactured by Bull Moose Tube Co. EZ refers to Listed/Approved EZ -Flow steel sprinkler pipe manufactured by Northwest Pipe & Casing Co. SF refers to Listed/Approved Super -Flo steel sprinkler pipe manufactured by Allied Tube and Conduit Corporation. SL refers to Listed/Approved steel sprinkler pipe manufactured by Western Tube and Conduit Corporation. NOTES Super 40/XL refers to Listed/ Approved Super 40 or Super XL steel sprinkler pipe manufactured by Allied Tube and Conduit Corporation. WLS refers to Listed/Approved steel sprinkler pipe manufactured by Wheatland Tube Company. XL/XL-II refers to Listed/Approved XL or XL -II steel sprinkler pipe manufactured by Allied Tube and Conduit Corporation. Working Pressure and End Load are total, from all internal and external loads, based on standard weight (ANSI) steel pipe, standard roll or cut grooved in accor- dance with Victaulic specifications. Contact Victaulic for performance on other pipe. WARNING: FOR ONE TIME FIELD TEST ONLY, the Maximum Joint Working Pressure may be increased to 1'h times the figures shown. t For field installation only. FireLock Style 005 couplings are essentially rigid and do not accommodate expansion/contraction. Number of bolts required equals number of housing segments. Metric thread size bolts are available (color coded gold) for all coupling sizes upon request. Contact Victaulic for details. § Style 005 couplings are VdS and LPC Approved to 12 Bar (175 PSI). WARNING: Piping systems must always be depressurized and drained before attempting disassembly and removal of any Victaulic piping products. This product shall be manufactured by Victaulic Company. All products shall be installed in accordance with current Victaulic Installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. 10.90-2 Rated Working Pressure Rated Working Pressure Pipe Schedule Size Inches UL ULC FM Pipe Schedule Size Inches UL ULC FM 5 11/4- 3 175 175 175 EZ 4 300 300 300 10,40 11/4 - 4 350 350 350 6 175 175 175 5 - 8 300 300 300 SF 11/4 - 4 300 300 300 BLT 11/4 - 2 300 300 300 Super 40 11/4 - 2 300 300 300 DF 11/4 - 4 300 300 300 TL 11/4 - 2 300 300 300 6 175 175 175 WLS 11/4 - 2 300 300 300 DT 1'/4 - 2 300 300 300 XL/XL-II 1'/4 - 3 300 300 300 EL 1'/4 - 2 300 300 300 NOTES: 5 refers to Listed/Approved Schedule 5 steel sprinkler pipe 10 refers to Listed/Approved Schedule 10 steel sprinkler pipe. 40 refers to Listed/Approved Schedule 40 steel sprinkler pipe. BLT refers to Listed/Approved steel sprinkler pipe manufactured by American Tube Company. DF refers to Listed/Approved Dyna -Flow steel sprinkler pipe manufactured by American Tube Company. DT refers to Listed/Approved Dyna Thread steel sprinkler pipe manufactured by American Tube Company. EL refers to Listed/Approved Eddylite steel sprinkler pipe manufactured by Bull Moose Tube Co. EZ refers to Listed/Approved EZ -Flow steel sprinkler pipe manufactured by Northwest Pipe & Casing Co. SF refers to Listed/Approved Super -Flo steel sprinkler pipe manufactured by Allied Tube and Conduit Corporation. SL refers to Listed/Approved steel sprinkler pipe manufactured by Western Tube and Conduit Corporation. NOTES Super 40/XL refers to Listed/ Approved Super 40 or Super XL steel sprinkler pipe manufactured by Allied Tube and Conduit Corporation. WLS refers to Listed/Approved steel sprinkler pipe manufactured by Wheatland Tube Company. XL/XL-II refers to Listed/Approved XL or XL -II steel sprinkler pipe manufactured by Allied Tube and Conduit Corporation. Working Pressure and End Load are total, from all internal and external loads, based on standard weight (ANSI) steel pipe, standard roll or cut grooved in accor- dance with Victaulic specifications. Contact Victaulic for performance on other pipe. WARNING: FOR ONE TIME FIELD TEST ONLY, the Maximum Joint Working Pressure may be increased to 1'h times the figures shown. t For field installation only. FireLock Style 005 couplings are essentially rigid and do not accommodate expansion/contraction. Number of bolts required equals number of housing segments. Metric thread size bolts are available (color coded gold) for all coupling sizes upon request. Contact Victaulic for details. § Style 005 couplings are VdS and LPC Approved to 12 Bar (175 PSI). WARNING: Piping systems must always be depressurized and drained before attempting disassembly and removal of any Victaulic piping products. This product shall be manufactured by Victaulic Company. All products shall be installed in accordance with current Victaulic Installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. 10.90-2 FireLock® Fittings PRODUCT DESCRIPTION DIMENSIONS 4CtoE l ctoE� to E I _� o0 No. 001 No. 003 c to E a L 0 T �� T� 'Co ode E No. 002 No. 006 10.03 VICTAULIC' IS AN 1509001 CERTIFIED COMPANY FireLock°° products comprise a unique system specifically designed for fire protection services. FireLock full -flow elbows and tees are a CAD -developed, hydrodynamic design that has a shorter center -to -end dimension than standard fittings. A noticeable bulge allows the water to make a smoother turn to maintain similar flow characteristics as standard full flow fittings. FireLock fittings are designed for use exclusively with Style 005 FireLock couplings. Use of other couplings or flange adapters may result in bolt pad interference. Victaulic FireLock fittings pressure ratings conform to the ratings of Victaulic FireLock Style 005 couplings. Patented FM See Victaulic publication 10.01 for details. 0 REGISTERED TRADEMARK OF VICTAULIC - O COPYRIGHT 2003 VICTAULIC - PRINTED IN U.S.A. Victaulic Company of AmP-rica • Phone: 1-800-PICK-VIC (1-800-742-5842) • Fax: 610-250-8817 • c-rrlail:pickvicnvictaulic.cum Victaulic. Company of Canada • Phone.: 905 884-7444 • Fax: 905.884-9774 • e-mail: viccanada69Viciaulir. rant Victaulic t{urnpe • I''hnne.:32 9-381-1500 • Fax: 32 9-380-4438 • e-mail: viceuro(:�victaulic.be Victaulic Anurica Latina • Phone.: 610-559-3300 • Fax: 610.559-3608 • e-mail: Vica11<aVictaulir..c0rn Victaulic Asia Pacific • Phone: 65-6235-3035 • Fax: 65-6235-0535 • e-mail: vicapCovictaulic.corn 1539 REV D /Cictaulic' No. 001 No. 003 No. 002 No. 006 Fitting Size 90' Elbow 45' Elbow Straight Tee Cap Actual Aprx. Al Aprx. Thickness Aprx. Nominal Outside C to E Weight C to E Weight C to E Weight "T' Weight Diameter Diameter Inches Each Inches Each Inches Each Inches Each Inches/mm Inches/mm mm LbsAg mm LbsAg mm LbsAg mm LbsJkg 1'/, 1.660 - - - - - - 0.82 0.3 32 42.4 - - - - - - 21 0.1 11/2 1.900 - - - - - - 0.82 0.4 40 48.3 - - - - - - 21 0.2 2 2.375 2.75 1.7 2.00 1.8 2.75 2,4 0.88 0.6 50 60.3 70 0.8 51 0.8 70 1.1 22 0.3 2'/r 2.875 3.00 3.1 2.25 2.2 3.00 3.6 0.88 1.0 65 ''.0 76 1.4 57 1,0 76 1,6. 22 0.5 3.000 3.00 3.30 2.25 2.4 - - - - 76.1 mm 76.1 76 1,5 57 I,l - - - - 3 3.500 3.38 4.0 2.50 3.1 3.38 5.3 0.88 1.2 80 88.9 86 1.8 64 1.4 86 2.4 22 0.5 4 4.500 4.00 6.7 3.00 5.6 4.00 8.7 1.00 2.4 100 114.3 102 3.0 76 2.5 102 3.9 25 1 i,l 5 5.563 4.88 12.6 3.25 8.3 4.88 15.7 1.00 4.1 125 1413 124 5,7 83 3,8 124 7.1 25 1.9 6 6.625 5.50 18.3 3.50 11.7 5.50 22.7 1.00 5.9 150 168.3 140 8.3 89 5.3 140 10.3 25 2.7 8 8.625 6.81 25.5 4.25 20.4 6.94 38.7 1.13 12.7 200 219.1 173 11,6 108 9.3 176 17.6 29 5.8 0 REGISTERED TRADEMARK OF VICTAULIC - O COPYRIGHT 2003 VICTAULIC - PRINTED IN U.S.A. Victaulic Company of AmP-rica • Phone: 1-800-PICK-VIC (1-800-742-5842) • Fax: 610-250-8817 • c-rrlail:pickvicnvictaulic.cum Victaulic. Company of Canada • Phone.: 905 884-7444 • Fax: 905.884-9774 • e-mail: viccanada69Viciaulir. rant Victaulic t{urnpe • I''hnne.:32 9-381-1500 • Fax: 32 9-380-4438 • e-mail: viceuro(:�victaulic.be Victaulic Anurica Latina • Phone.: 610-559-3300 • Fax: 610.559-3608 • e-mail: Vica11<aVictaulir..c0rn Victaulic Asia Pacific • Phone: 65-6235-3035 • Fax: 65-6235-0535 • e-mail: vicapCovictaulic.corn 1539 REV D /Cictaulic' 10.03 FLOW DATA t fhe flow data listed is based upon the pressure drop of Schedule 40 pipe. MATERIAL SPECIFICATIONS Fitting: Ductile iron conforming to ASTM A-536, grade 65-45-12 Fitting Coating: Orange enamel • Optional: Hot dipped galvanized this product shall be manufactured by Victaulic Company. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. FireLockw Fittings Frictional Resistance Fitting Size Equivalent Feet/meters of Straight Pipe Actual Straight Tee Nominal Outside No. 002 Diameter Diameter 90' Elbow 45' Elbow Branch Run inches/mm Inches/mm No. 001 No. 003 2 2.375 3.5 1.8 8.5 3.5 50 60,3 1.1 0.5 2.6 1.1 21/2 2.875 4.3 2.2 10.8 4.3 65 73,0 1,3 0.7 3.3 1,3 76.1 mm 3.000 4.5 2.3 11.0 4.5 76.1 1,4 0.7 3.4 1.4 3 3.500 5.0 2.6 13.0 5,0 80 88.0 1,5 0.8 4.0 1,5 4 4.500 6.8 3.4 16.0 6.8 100 114.3 2.1 1.0 4A 2.1 5 5.563 8.5 4.2 21.0 8.5 125 1 141.3 2.6 1.3 6.4 2,6 6 6.625 10.0 5.0 25.0 10.0 150 168.3 3.0 1,5 7,6 3.0 8 8.625 13.0 5.0 33.0 13.0 200 219.1 4.0 1.5 10.1 4.0 t fhe flow data listed is based upon the pressure drop of Schedule 40 pipe. MATERIAL SPECIFICATIONS Fitting: Ductile iron conforming to ASTM A-536, grade 65-45-12 Fitting Coating: Orange enamel • Optional: Hot dipped galvanized this product shall be manufactured by Victaulic Company. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. FireLockw Fittings ®ct ulic An 44 9001 certified company I s 11 _Ile y Series 717R FireLock check valve incorporates a CAD -developed design that is hydrodynamically effi- cient and available in 4 - 8" (100 - 200 mm) sizes. The DIMENSIONS "/<R�J Series 717R utilizes a totally rubber encapsulated disc to provide superior corrosion resistance. This single disc design incorporates a spring assisted feature for non -slamming operation. Approved for vertical or horizontal installations, the Series 717R is designed to accept a riser check kit. The kit consists of a 2" (50 mm) drain valve, 0 - 300 PSI (0 - 2065 kPa) gauges (2), gauge isolation valves (2), pipe nipples and pipe plugs. The Series 717R does not include the riser check kit unless specified and ordered. A welded -in nickel seat provides extra corrosion protection and leak -free sealing under as low as five T, U T U B }C 2' NPT O I II 4 F H� H J E . Y.' NPT Series 717 FireLock" Check Valves (5) feet of head. The basic valve is factory tested and is UL/ULC Listed and FM Approved. The 2" (50 mm) drain valve is UL/ULC Listed and FM Approved for services up to 200 PSI (1370 kPa). Grooved ends allow fast, easy installation with just two Victaulic cou- plings or the valve may be mounted to flanged (ANSI CL. 150) equipment using Victaulic Style 741 Vic-Flange`s or Style 744 FireLock flange adapters on either end. 10,0918 Viclaulic Company of America • P.O. Box 31, Easton, PA 18044-0031 • 4901 Kesslersville Ad., Easton, PA 18040 • 610/559-3300 • FAX: 610/250-8817 • www.victaulic.com 1540110 .B 10/96 9 Registered Trademark Viclaulic Company of America - ,o Copyright 1996 vlctaulic company of America Printed In U.S.A. Dimensions- Inches/millimeters Nom. Size Inches Mir, Actual Size Inches Mr, E - E A B C D E F H J K L M N Approx. Wgt. Ea. Lbs. kq 4 4.500 9.63 6.25 4.00 375 14.25 6.88 6.70 10.45 11, 25 2.00 2.00 5.25 28.0 5 5.563 10.50 6.50 4.25 3.75 14.75 7.38 7.37 11.87 12.75 2.15 1.88 5.25 35.0 51h 5.500 10.50 6.50 4.25 3.75 14.75 7.38 7.37 11.87 12.75 2,15 1.88 5.25 35.0 6 6.625 11.50 7.63 5.38 3.75 15.50 8.03 7.70 12.20 13.00 2.38 2.13 5.25 46.0 61h O.D. 6.500 11.50 :: 7.63 hl 5.38 ; 3.75 15.50 8.03 7.70 12.20 13.00 2.38 2.13 5.25 46.0 8 8.625 14.00 8.25 6.00 3.75 16.38 9.00 8.85 12.75 13.501 2'15 2.88 1 5.25 72.0 Viclaulic Company of America • P.O. Box 31, Easton, PA 18044-0031 • 4901 Kesslersville Ad., Easton, PA 18040 • 610/559-3300 • FAX: 610/250-8817 • www.victaulic.com 1540110 .B 10/96 9 Registered Trademark Viclaulic Company of America - ,o Copyright 1996 vlctaulic company of America Printed In U.S.A. FLOW CHARACTERISTICS NOTE: Placement of check valves too close to sources of unstable flow will shorten the life of the valve and potentially damage the system. To extend valve life, valves should be installed a reasonable distance downstream from pumps, elbows, expanders, reducers or other similar devices Sound piping practices dictate a minimum of live (5) times the pipe diameter for general use. Distancesbetween three (3) and live (5) diameters are allowable provid- ed the flow velocity is less than eight (8) feet per second (2.4 mps). Dis- tances less than three (3) diameters are not recommended and will vio- late the Victaulic product warranty. 6.0 5.0 4.0 3.0 N 2.0 a I a O 1.0 0.9 w 0.8 0,7 0.6 W 0.5 a 0.4 0.3 0.2 0.1 SERIES 717R MEN 110 10 20 30 40 60 80 100 200 300 400 600 1,000 2,000 4,000 6,000 10,00 B00 3,000 8,000 MATERIAL SPECIFICATIONS Body: Ductile iron conforming to ASTM A-536, Grade 65-45-12, painted black enamel. Body Seat: Integrally welded on nickel alloy. Disc Coating: 0 Grade "E" EPDM EPDM (Green color code). Temperature range —30°F to +230°F (-34°C to +110°C). Recommended for cold and hot water service within the specified temperature range plus a variety of dilute acids, oil -free air and many chemi- 10,09-2 FLOW RATE - G.P.M. cal services. UL classified in accordance with ANSI/NSF 61 for cold (30°C) and hot (82°C) potable water service. NOT RECOMMENDED FOR PETROLEUM SERVICES. 'Services listed are General Ser- vice Recommendations only. It should be noted that there are services for which these gaskets are not recommended. Refer- ence should always be made to the latest Victaulic Gasket Selection Guide for specific gas - 20,000 ket service recommendations and for a listing of services which are not recommended. Discs: Ductile iron conforming to ASTM A-536 Grade 65-45-12, fully encapsulated in Grade "E" elastomer. Shaft: Type 316 stainless steel. Spring: All sizes Type 302/304 stainless steel. Shaft Plug: Carbon steel zinc plated to ASTM B-633. Pipe Plug: Carbon steel zinc plated to ASTM B-633. This product shall be manufactured by Victaulic Company_ All products shall be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. iCl.f �dliC® Y The Series 705W butterfly valve features a weatherproof actuator housing approved for indoor or Outdoor use. it. has a ductile iron body and disc with EPDM disc coaring. The body is coated with a heat ,`used polyphenylene sulfide blend to meet FM requirements and 21/2 6" Sizes r.he new coaring lecu:rements for the 5th edition of UL 1091. For fire protection services, Request Viclaolic Series 705W valve is UL Listed 8 12" Sizes o1blication 10.01 for details. DIMENSIONS Series 705W FireLockTm Butterfly Halve With Weatherproof Actuator For 300 PSI Service and FM Approved for 300 PSI (2065 kPa) service. Flow per- formance exceeds UL Specifi- cation 1091 and FM Approval Standard 1112. Weatherproof Actuator Supervisory switches for valves are available 2'/2 - 12" (73,0 - 323,9 mm) pre -wired (PW). Supply-side Tap Series 705W valves are avail - able with a'/4" NPT supply side tap designed to allow direct water supply connec- tion to Victaulic FireLock actu- ated fire protection valves. See separate drawings below. This is an optional feature and must be clearly noted on all orders. Contact Victaulic for addi- tional information on tapped valves. o 'A NPT 4f l Supply Tapl it it O1II 0 N -M-NpH- -A-► Series 705W with Tap SIZE Dimensions - Incheshnrlirn..tl),s Aprx Nominal In. E to E A Hgt. B C D E F G H J K L O M I N P Wgt. Ea. Lbs.ls: 2112 3.77 9.80 1.80 3.92 - 2.88 6.97 5.45 7.02 0.97 2.31 4.50 1.44 0.60 1.03 9.1 76.1 mm 3.77 9.80 1.80 3.92 - 2.88 6,97 5,45 7.02 0.97 2.31 4,50 1.50 0.60 1.03 9.1 3 3.77 10.48 2.14 4.22 0.08 3.50 7.61 5.45 7.33 0.97 2.31 4.50 1.75 0.00' 0.80 9.8 4 4.63 11.89 2.71 5.09 0.07 6.01 9.05 5.45 8.59 0.97 2.79 4.50 2.60 0.73 1.22 15.3 139.7 mm 5.88 12.82 3.12 5.61 0.43 6.01 9.98 5.45 8.59 0.97 3.92 4.50 - - - 20.0 5 5.88 12.82 3.12 5.61 0.43 6.01 9.98 5.45 8.59 0.97 3.92 4.50 - - - 20.0 165,1 cnm 5.88 13.74 3.61 6.06 1.00 7.20 10.92 5.45 9.05 0.97 3.96 4.50 3.25 1.25 1,50 25.0 6 5.88 13.74 3.61 6.06 1.00 7.20 10.92 5.45 9.05 0.97 3.96 4.50 3.32 1.25 1.50 25.0 8 5.33 16.92 4.88 7.94 1.27 10.20 14.06 8.28 13.30 2.05 2.66 6.00 5.10 0.18 0.91 52.0 10 1 6.40 19.14 5.84 8.69 1.72 12.20 15.77 10.09 16.19 2.05 3.20 9.00 - - - 80.0 12 t 6.50 21.54 7.04 10.00 2.66 14.25 18.28 10.09 17.22 2.05 3.25 9.00 - - - 102.0 Un centerline. t Contact Victaulic Company of Canada for ULC Listings. I. ro prevent rotation of valves. it is recommended that Series 705W be installed vnth Victaulic Style 07 Zoro-Flex'. Style 005 FireLock" or Style HP 70 Rigid Couplings If Victaulic Ilexrble couplings arc used. Adilronal suppon may be rcgwrcd. 2. Valve must not be installed with disc in full open position. DI; -c must be partly closed so that no part is protruding beyond end of valve body. 3. Victauhc grooved end butterfly valves are permitted for use with grooved end pipe OPS) only. Not permitted for use with plain end (IPS) of grooved end cast ductile iron pipe. 4. Senor: 705W valves are designed for anlbiont weather conditions as opposed to whiner slble service. VICTAULIC" IS AN ISO 9001 CERTIFIED COMPANY Vic* ;luiic Company of America Victaulic Cornparly of Canada Victaulic Europe Victaulic Arnerica Latina Victaulic Asia P;.-tcifir- Phone:l-800-PICK-VIC (1-800-742-5842) Phone: 416-675-505 Phone:32-9-381-1500 Phone: 610-559-3300 Phone: 65-235-3035 Fax: 610-250-8817 Fax:416-675-5565 Fax: 32-9.380-4438 Fax: 610-559-3608 Fax: 65-235-0535 e-mail:pickviccCwictaulic.cont e-mail: viccanatia@vlctauhc.com e-mail: viceuro `Vicl;ullicbe e-mail: vicalQviclaulir..cool e-mail: vicapeovictaulic.com 2,166 Rm, 8 11/01 J0 Registered Trademark of Victauhc 0 Copyright 2001 Virtaoi,c Pnnled m U.S A. MATERIAL SPECIFICATIONS Body: Ductile Iron conforming to ASTM A-395, grade 65-45-15. and ASTM A-536, grade 65-45- 12, coated with polyphenylene sulfide blend. Disc: Ductile iron conforming to ASTlvI A-395, grade 65-45-15, and ASTM A-536, grade 65-45- [2, EPDM coating P)99i ' f�!d��iJlf�kiUrPi�krm �' Mi'. •=1 0.48 2 The chart expresses the frictional resistance of Victaulic Series 705W in equivalent feet/meters of straight pipe. SIZE UL LISTED SIZE .\ JUNCTION BOX - / Nom. Equiv. Nom. Equiv. In. FeeUr In FeeUm Il III CONDUIT of a;:.,.:.i of Ac:r,;;,f min Pipe /2 Pipe z 5 8 8 76.1 mm 325 165.1 # 1150 76.1 # 5 6 8 3 5 8 11 4 12 10 12 139.7 $ 12 1.2 14 5 12 t nnllinletcrs Disc Coating: ❑ Grade "E" EPDM EPDM (Green color code). Temperature range -30°F to +230°F (-34°C to , 110"C). Recommended for cold and hot water service within the specified temperature range plus a variety of dilute acids, oil -free air and many chemi- cal services. UL classified in accordance with ANSI/NSF C„ Values C„ values for flow of water at +60°F (+16°C) with a fully open valve are shown in the table below. For additional details contact Victaulic. 61 for cold +86°F (+30°C) and hot +180°F (+82°C) potable water service. NOT RECOM- MENDED FOR PETROLEUM SERVICES. Stem Bearings: Teflon impreg- nated fiberglass with stainless steel backing. Stem Bearing Nuts: Carbon steel, nickel plated Tap Plug: Carbon steel, plated. Formulas for Cv Values: M= Q, CV - Q = Cvx[A—p Bracket: Carbon steel, painted Actuator: ❑ 2'/2 - 6" (73,0 - 168,3 mm): Bronze traveling nut on a steel lead screw. in a steel housing. ❑ 8 - 12" (219,1 - 323,9 mm): Steel worm and cast iron quad- rant gear, in a cast iron housing. Where: Q = Flow (GPM) AP = Pressure Drop (PSI) C„ = Flow Coefficient SIZE UL LISTED SIZE .\ JUNCTION BOX - / SIZE Nominal Inches C„ Nominal Inches C„ Nominal Inches C„ Il III CONDUIT (Full Open) ;l rauai mm (Full Open) Ac:r,;;,f min (Full Open) /2 325 139.7 mm 1150 8 3400 76.1 mm 325 5 1150 10. 5750 3 482 165.1 mm 1850 12 8300 4 600 6 1850 SWITCH AND WIRING Supervisory Switch 21/2 - 12" (73,0 - 323,9 mni) sizes: Series 705W PW - Two, single pole, double throw, pre- wired switches. Switches are rated IOA @ 125 or 250 VAC 60 Hz and 0.25A @ 250 VDC. 0.50A @ 125 VDC Supervisory Switch Wiring A. Pre -wired Switches (l) Switches Supervise Open Valve (2) One switch has two N 18 MTW wires per terminal. Permits complete supeivi sion of leads (see dia- grams below). Second switch has one H 18MTW wire per terminal. This double circuit provides 10.18 - 2 flexibility to operate two electrical devices at sepa- rate locations such as an indicating light and an audible alarm in the area at the valve installation. Switch NI Sl Switch #2 S2 ( Normally Closed: (2) Blue S IllNormally Open: (2) Brown Common: (2) Yellow Normally Closed: Blue with Stripe S2 Normally Open: Brown with Stripe Common: Yellow with Stripe (3) A ground lead, .41 VvITW is provided (green) NOTE: Connecting to Common Terminals (Yellow Sl and Yellow with Orange Stripe S2). and Normally Closed Terminals (Blue Sl and Blue with Orange Stripe S2): e.g., indi Cator light and alarm stays on until valve Is fully opened; then indicator light and alarm go out. Cap off unused wire, ag.. Brown and Brown with Orange Stripe, Actuator Repair In the unlikely event of an actua- tor failure, complete actuation replacement is required. ALL REPLACEMENT PARTS MUST BE OBTAINED FROM THE MANUFACTURER TO ASSURE PROPER OPERATION OF THE VALVE. This product shall be manufactured by ViclauliC Company. All products shall be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and slandard equipment without notice and without incurring Obligations. UL LISTED CONDUIT .\ JUNCTION BOX - / NPT ' — Il III CONDUIT CONNECTORS WIRE NUTS NOTE: Connecting to Common Terminals (Yellow Sl and Yellow with Orange Stripe S2). and Normally Closed Terminals (Blue Sl and Blue with Orange Stripe S2): e.g., indi Cator light and alarm stays on until valve Is fully opened; then indicator light and alarm go out. Cap off unused wire, ag.. Brown and Brown with Orange Stripe, Actuator Repair In the unlikely event of an actua- tor failure, complete actuation replacement is required. ALL REPLACEMENT PARTS MUST BE OBTAINED FROM THE MANUFACTURER TO ASSURE PROPER OPERATION OF THE VALVE. This product shall be manufactured by ViclauliC Company. All products shall be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and slandard equipment without notice and without incurring Obligations. The In -Building Riser shall be composed of a single extended 90 degree fitting of fabricated 301 stainless steel tubing, maxirnunt working pressure of 17-D PSI. The Fitting shall have a grooved -end connection on the outlet (building) side and a CIPS coupler on the underground (inlet) side. The fitting shall be similar in all respects to the Arses Model "In -Building Riser" as manufactured in the U.S.A. by AMES Company, Inc.,Woodland, Ca., or approved equal. Ineratinir Descrintir The In -Building riser is used to connect the main fire supply to the building overhead Fire system.The fitting passes under the Foundation without joints and extends up through the floor.The unit has a CIPS (Cast Iron Pipe Size) coupler for easy connection to the underground supply (AWWA C900 PVC) and an industry standard grooved -end connection (AWWA C606) on the building side for easy connection to the overhead fine sprinkler system. (Provided with installation tabs). `Features/Benefits `' . Cost Savings • Corrosion Resistant- stainless steel construction type 304SST • Ease of Installation - lightweight allows one person to position & handle the riser AMES CO introduces the AMES -............ "In -Building Riser," manufactured of series 300 stainless steel. Using Twenty First Century technology, AMES has succeeded in the manufacture of a durable and easy to install underground transition fitting to bring municipal water supply Into a building. In -building riser is Ideally suited for fire protection systems. -Minimal Site preparation or joint restraint- one-piece construction reduces time & labor: no missing parts, no leaks, easily identifiable for approvals • UL/FM Approval A Division of Watts Industries, Inc. • Sizes: available in 4" through 10" . with various lengths to meet all local requirements • Designed to meet NFPA 24 Section 8-3.2 • AWWA C900 Inlet • AWWA C606 Outlet FLUID CONTROL SYSTEMS 530-666.2493 • 1485 Tanforan Avenue • P.O. Box 1387 • Woodland, CA 95776 • FAX 530.666-3914 )imensic Size A B C Weight in. in, ft. ft. lbs. 4 41/2 OD 6 6 71 6 65/8 OD 6 6 98 8 85/8 OD 6 6 129 10 103/4 OD 6 6 202 41, Each diameter (A) of riser Is available In the following vertical/outlet (B) and horizontal/inlet (C) leg dimensions. Call forweight. B C ft. ft. 5 6 I� A 5 7 Grooved End 8 6 T B i I CIPS Coupling I Tie -Rod bracket I Arles In -Building Risers are precision engineered and manufactured to provide exceptional reliabilityThe Acnes In -Building Risers significantly reduce installation time and labor costs associated with field assembly. In accordance with NFPA-24, the UL/FM Approved Ames In -Building Riser replaces numerous fittings, elbows, spools and reduces the possibility of leaks or failure in 1H CO. ji 6 FLUID CONTROL SYSTEMS comparison to traditional installation methods and materials. Factory tested integrity ensures the highest quality installation. The use of stainless steel significantly increases the reliability and life of the Riser. To learn more about the many advantages Ames In -Building Risers offer, contact your local Ames Representative. A Division of Watts Industries, Inc. Bell End: Mates with Ductile Iron Pipe and AWWA C900 Pipe (PVC Pipe with Cast Iron Pipe Equivailent OD's) Size Mating Pipe OD 4" 4.30 6" 6.90 8" 9.05 10" 11.10 Utilizes Gasket conforming to UL 157 with "Lock in" gasket configuration <X=300 3 Meets AWWA C-606 dimensions for roll grooved pipe 4220000 Meets AWWA C-900 pressure class 200, DR la Pipe Welds are 100% leak tested at the factory Size Design Proof Pressure (psi) 4" 475 6" 875 8" 700 10" 700 t . NFPA — Designed to allow the contractor to conform to NFPA 24 Section 8-3.2: Where a riser is close to building foundations, underground fittings of proper design and type shall be used to avoid pipe joints being located under the foundations. NFPA — 24, 7.1.1,8-3.4 Approved ��� '. UL (HKOX) 530.666-2493 • 1485 Tanforan Avenue • P.O. Box 1387 • Woodland, CA 95776 • FAX 530-666.3914 M83-50 2/00 UL ULC/Canadian Models Models W FD20 W FD20A W FD25 W FD25A W FD30-2 W FD30-2A W FD35 W FD35A W FD40 W FD40A W FD50 W FD50A W FD60 W FD60A W FD80 W FD80A Replacement Parts A3008-00 Retard Mechanism A77-01-02 Terminal Block 546-7000 Cover Tamper Switch Kit WFDW Cover Wrench WFDN4 Replacement gasket kit Ar Product Overview New WFD30-2 models install in 2" hole sizes System Sensor's WFD series is compatible with schedule 10 through 40 steel pipe, sizes 2" through 8", and can be mounted in a vertical or horizontal position. UL models are NEMA 4 rated Robust Construction. The WFD series consists of a rugged, NEMA 4 rated Sealed retard mechanism assures that enclosure. Designed for both indoor and outdoor use, the WFD series operates the retard is not contaminated by dust across a wide temperature range, from 32°F to 120°F. and dirt when the cover is removed Reliable Performance. UL listed models are equipped with tamper resistant Visual switch activation permits cover screws to prevent unauthorized entry. Inside, two sets of SPDT (Form Q installer to accurately set retard under synchronized switches are enclosed in a durable terminal block to assure noisy conditions reliable performance. Rugged, dual SPDT switches are enclosed in a durable terminal block False Alarm Immunity. The WFD series incorporates a mechanical retard fea- ture, which minimizes the risk of false alarm due to pressure surges or air Accommodates up to 12 AWG wire trapped in the sprinkler system. In addition, the mechanical retard's unique 100% synchronization activates sealed design is immune to dust and other contaminants. both alarm panel and local bell Simplified Operation. The WFD series is designed to simplify installation. Two simultaneously conduit openings permit easy attachment to the local alarm system. The retard mechanism and dual SPDT switches are field -replaceable. MEA LISTED APPROVED approved �: Engineering Specifications Vane -type waterflow detectors shall be installed on system piping as designated on the drawing and/or as specified herein. Detectors shall mount on any clear pipe span of the appropriate nominal size, either a vertical upflow or horizontal run, at least 6" from any fittings which may change water direction, flow rate, or pipe diameter or no closer than 24" from a valve or drain. Detectors shall have a sensitivity in the range of 4 to 10 gallons per minute and a static pressure rating of 450 psi* for 2" - 8" pipes. The detector shall respond to waterflow in the specified•direction after a preset time delay which is field adjustable. The delay mechanism shall be a sealed mechanical pneumatic unit with visual indication of actuation. The actuation mechanism shall include a polyethylene vane inserted through a hole in the pipe and connected by a mechanical linkage to the delay mech- anism. Outputs shall consist of dual SPDT switches (Form C contacts). Two conduit entrances for standard fittings of commonly used electrical conduit shall be provided on the detectors. A grounding provision is provided. Unless noted, enclosures shall be NEMA 4 listed by Underwriters Laboratories Inc. All detectors shall be listed by Underwriters Laboratories Inc. for indoor or out- door use. Standard Specifications Static Pressure Rating 450 Psi - Triggering Threshold Bandwidth (Flow Rate) 4-10 GPM Maximum Surge 18 Feet Per Second (FPS) Compatible Pipe: Steel water pipe, schedule 10 through 40 Contact Ratings Two sets of SPOT (Form C) 10.0 A, 1/2 HP @ 125/250 VAC 2.5 A @ 6/12/24 VDC Overall Dimensions Installed �0- Conduit Entrances Two openings for i4" conduit. One open, one knock -out type Operating Temperature Range 32*F to 120*F (0*C to 49*C) Enclosure Rating - NEMA 4 - suitable for Indoor/outdoor use Cover Tamper Switch Standard with ULC models Optional for UL models, part no. 546-7000 Shipping Weight W FD20: 4.2 lbs. WFD25: 4.3ibs. W FD30-2: 4.5 lbs. WFD35: 4.7 lbs. J bolt n„t Pipe u444 Ordering Information WFD40: 5.2 lbs. W FD50: 6.3lbs. WFD60: 6.8 lbs. WFD80: 7.5 ibs. UL Model Numbers ULC/Canadian Model Numbers Pipe Size Hole Size WF020 WFD20A 2" 114" WFD25 WFD25A 21/2" 114" WFD30-2 WFD30-2A 3" 2" WFD35 WFD35A 31/2" 11/4" WFD40 WFD40A 4" 2" WFD50 WFD50A 5" 2" WF060* WFD60A 6" 2" WFD80* WFD80A 8" 2" *Maximum pressure rating 400 psi as approved by Factory Mutual. System Sensor Sales and Service System Sensor Headquarters System Sensor Canada System Sensor In China 3825 Ohio Avenue Ph: 905.812.0767 Ph: 86.29.524.6253 St. Charles, IL 60174 Fx: 905.812.0771 Fx: 86.29.524.6259 Ph: 800/SENSOR2 System Sensor Europe System Sensor in Singapore Fx: 630/377-6495 Ph: 44.1403.276500 Ph: 65.6273.2230 Documents -on -Demand Fx: 44.1403.276501 Fx: 65.6273.2610 800/736-7672 x3 www.systemsensor.com 02002 System Sensor. The company reserves the right to change product specifications without notice Service Use Automatic Sprinkler: NFPA-13 One or Two Family Dwelling: NFPA 130 Residential Occupancies up to 4 Stories: NFPA 13R National Fire Alarm Code: NFPA-72 Warranty 3 Years U.S. Patent Numbers 3,845,259 4,782,333 5,213,205 Part Number Description A3008-00 Retard mechanism A77-01-02 Terminal block 546-7000 Tamper proof switch kit WFDW Tamper proof wrench for cover WFDN4 Gasket kit System Sensor - Far East Ph: 85.22.191.9003 Fx: 85.22.736.6580 System Sensor - Australia Ph: 613.54.281.142 Fx: 613.54.281.172 System Sensor - India Ph: 91.124.637.1770 x.2700 Fx: 91.124.637.3118 A05-0180-008-04/02-#947